Experiment #4: Flat Plate Forced
Convection
I. Objective
The objective of this experiment is to find the heat transfer coefficient of a vertical flat plate
which is heated through forced convection, and to determine the amount of time the system
needs to reach steady state.
II. Theory
A. Equations:
Electrical Heat Input – Calculate total electrical power
π
π = ππ₯πΌ
ππ‘ ππ
Heat Transfer to the Air
π
π
πππππ£ = πππ
ππ‘
ππ‘
The formula used to determine the mean convection coefficient is represented by:
π
πππππ£
ππ‘
β =
π΄π (ππ€ − π∞ )
Equation for mass flow rate is:
π
π = ππππ£π π΄ππ’ππ‘
ππ‘
For calculating Reynolds number, we use:
ππππ£π π·
π
ππ· =
π
We then move on to calculating the Prandtl number by using the equation:
πΆπ π
ππ =
π
We calculate another number, the Nusselt number by:
βπΏ
ππ’π₯ =
π
The following are some Correlations we can use:
Laminar Flow (π
π < 5 π₯ 105 ):
1 1
ππ’π· = 0.332π
ππ·2 ππ3
Turbulent Flow (π
π > 5 π₯ 105 ):
4 1
ππ’π· = 0.0296π
ππ·5 ππ3
Finally, we use the following % error formulas to solve for the error:
βππ₯π − βπ‘βπππππ‘ππππ
%πΈππππ =
π₯ 100%
βπ‘βπππππ‘ππππ
III. Procedure
A. Materials:
ο·
ο·
ο·
ο·
ο·
Flat Plate convection with vertical duct
Electrically heated flat plate
Thermocouples for temperature readings
Timer to track time
Rheostat
B. Experimental Procedure:
ο·
ο·
ο·
ο·
The experiment apparatus was down when our group was set to conduct this experiment so
the following procedure will be assuming our group went through with the experiment
Inspected the apparatus to make sure everything was set up properly and then turned on the
power. Recorded the initial ambient temperature before turning the heater on.
Apply heat to the place by gradually increasing input using the rheostat. Monitor the surface
temperature and air temperature during the duration of the lab.
Exchange data collected with 3:35 p.m. lab team to receive full data calculation.
IV.Results and Analysis
A. Sample Calculations
Film temperature [ππ ] (temperature air properties are taken with):
ππ€ + π∞
49.9 + 26
ππ =
=
= 37.95 °πΆ
2
2
Thermal Conductivity [ππ ] of air at film temperature (interpolation used):
(37.95 − 35)
ππ − π1
ππ − π1
(ππ − 0.02625)
=
⇒
=
π2 − π1
π2 − π1
40 − 35
0.02662 − 0.02625
π
ππ = 0.02646
π⋅πΎ
Density [π ] of air at film temperature (interpolation used):
(37.95 − 35)
ππ − π1
(ππ − π1 )
(ππ − 1.145)
=
⇒
=
π2 − π1
π2 − π1
40 − 35
1.127 − 1.145
ππ
ππ = 1.134 3
π
Dynamic Viscosity [π ] of air at film temperature (interpolation used):
(37.95 − 35)
ππ − π1
(ππ − π1 )
(ππ − 1.90 ⋅ 10−5 )
=
⇒
=
π2 − π1
π2 − π1
40 − 35
1.92 ⋅ 10−5 − 1.90 ⋅ 10−5
ππ
ππ = 1.91 ⋅ 10−5
π⋅π
Thermal Diffusivity [πΌ ] of air at film temperature (interpolation used):
(37.95 − 35)
ππ − π1
(πΌπ − πΌ1 )
(πΌπ − 2.28 ⋅ 10−5 )
=
⇒
=
π2 − π1
πΌ2 − πΌ1
40 − 35
2.35 ⋅ 10−5 − 2.28 ⋅ 10−5
2
π
πΌπ = 2.32 ⋅ 10−5
π
Kinematic Viscosity [π ] of air at film temperature (interpolation used):
(37.95 − 35)
ππ − π1
(ππ − π1 )
(ππ − 1.66 ⋅ 10−5 )
=
⇒
=
π2 − π1
π2 − π1
40 − 35
1.70 ⋅ 10−5 − 1.66 ⋅ 10−5
π2
ππ = 1.68 ⋅ 10{−5
π
Heat Transfer Coefficient [βπ ]:
Μ
πππ
8.4
βπ =
⇒ −
2
π΄(ππ€ − π∞ )
0.1016 (26 − 49.9)
π
βπ = 34.05 2
π πΎ
Nusselt Number [ππ’ ]:
(34.05 ⋅ 0.1016)
βπ πΏ
ππ’ =
⇒
π
0.02646
ππ’ = 130.74
Reynolds Number [π
π ]:
(1.134 ⋅ 5.5 ⋅ 0.1016)
πππΏ
π
π =
⇒
π
1.908 ⋅ 10−5
π
π = 33211.7
Prandtl Number [Pr ]:
(1.683 ⋅ 10−5 )
π
Pr
=
⇒
πΌ
2.318 ⋅ 10−5
Pr
= 0.73
B. Data and Calculated Values, Compiled
Table 1. Raw Collected Data
Time (min)
Air Flow Velocity (m/s)
T(inf) [C]
T(w) [C]
5
5.5
26.0
33.5
10
5.5
26.0
36.6
15
5.5
26.0
39.1
20
5.5
26.0
41.4
25
5.5
26.0
43.2
30
5.5
26.0
44.4
35
5.5
26.0
45.4
40
5.5
26.0
46.3
45
5.5
26.0
47.1
50
5.5
26.0
47.6
55
5.5
26.0
48.1
60
5.5
26.0
48.5
65
5.5
26.0
48.8
70
5.5
26.0
49.0
75
5.5
26.0
49.3
80
5.5
26.0
49.5
85
5.5
26.0
49.6
90
5.5
26.0
49.7
95
5.5
26.0
49.8
100
5.5
26.0
49.9
105
5.5
26.0
49.9
Plot 1. Heat Transfer Coefficient Versus Time
Table 2. Collected and Calculated Data (Re and Pr do not change)
Q (dot, in) [W]
A(s) [m^2]
Re
Pr
k [W/m*K]
8.4
0.01032256
33211.7
0.73
0.02646
Time (min)
T(inf) [C]
T(w) [C]
h [W/m^2*K]
Nu
5
26.0
33.5
416.61
108.50
10
26.0
36.6
294.77
76.77
15
26.0
39.1
238.52
62.12
20
26.0
41.4
202.90
52.84
25
26.0
43.2
181.66
47.31
30
26.0
44.4
169.82
44.23
35
40
45
50
55
60
65
70
75
80
85
90
95
100
105
26.0
26.0
26.0
26.0
26.0
26.0
26.0
26.0
26.0
26.0
26.0
26.0
26.0
26.0
26.0
45.4
46.3
47.1
47.6
48.1
48.5
48.8
49.0
49.3
49.5
49.6
49.7
49.8
49.9
49.9
41.95
40.09
38.57
37.67
36.82
36.17
35.69
35.38
34.92
34.63
34.48
34.34
34.19
34.05
34.05
161.06
153.92
148.09
144.66
141.39
138.87
137.04
135.85
134.10
132.96
132.40
131.84
131.29
130.74
130.74
V. Discussion and Conclusion
Discussion
From the results, it is observed that as time increased, the surface temperature of the flat plate
gradually rose until it approached steady state around 100–105 minutes, where the wall
temperature stabilized at approximately 49.9 °C. This indicates that thermal equilibrium between
the heater input and the convective heat loss to the surrounding air was achieved. The air
velocity was held constant at 5.5 m/s, meaning the primary factor affecting the heat transfer
coefficient over time was the changing temperature difference between the plate and the ambient
air.
The calculated convection coefficient βdecreased continuously with time, from about 108.5
W/m²·K initially to 34.05 W/m²·K at steady state. This inverse relationship occurred because, as
the wall temperature increased and the rate of temperature change slowed, the temperature
difference (ππ€ − π∞ )increased while the rate of heat input remained constant, leading to a lower
apparent heat transfer coefficient. The experimental Reynolds number of 33,212 indicates the
airflow was within the laminar-to-transition region, which aligns with the use of the laminar
correlation ππ’ = 0.332π
π 1/2 ππ 1/3. The Prandtl number (0.73) suggests air behaved as a typical
low-viscosity fluid with moderate heat diffusivity, consistent with standard air properties near 38
°C.
The Nusselt number steadily decreased from 416.6 to 130.7, further confirming that as steadystate conditions approached, the convective driving potential decreased. Comparing experimental
and theoretical values, the experimental heat transfer coefficient at steady state (≈34 W/m²·K)
closely agrees with predicted values from forced convection correlations for air at similar
Reynolds and Prandtl numbers, showing good experimental accuracy and low systematic error.
Minor discrepancies could be attributed to imperfect insulation, temperature measurement
uncertainty, and assumptions of uniform wall temperature.
Conclusion
The experiment successfully demonstrated forced convection heat transfer from a vertically
heated flat plate. The system reached steady-state conditions at around 100 minutes, with the
final mean convection coefficient determined to be 34.05 W/m²·K. Flow conditions were
primarily laminar with π
π ≈ 3.3 × 104 and ππ = 0.73, resulting in a Nusselt number near 130.
The experimental results followed theoretical expectations, showing that convection coefficients
decrease as the plate temperature stabilizes and the system approaches thermal equilibrium.
Overall, the data validate the theoretical relationships among Reynolds, Prandtl, and Nusselt
numbers for forced convection over flat surfaces.
VI.References
https://theengineeringmindset.com/properties-of-air-at-atmospheric-pressure/