Experiment 9: Purification of Biphenyl
All students are responsible for both pre-lab assignments!
This is a team-based experiment. Each team consists of 4 students—2 students will do the recrystallization
experiment and 2 students will do the column chromatography experiment. You will share information with
your teammates. The data will then be shared with the entire class.
Purification of Biphenyl – Solubility, Hot Filtration, and Recrystallization
Assigned Reading: Recrystallization, Vacuum Filtration, Hot Filtration: Zubrick, Chapter 13
Questions:
What solvent can be used for an effective recrystallization of biphenyl from methyl orange dye? How well does
recrystallization work as a purification?
Procedures:
1. Miscibility tests: Using test tubes, test the miscibility of 0.5 mL of each of the following solvents with
water: methanol, acetone, 95% ethanol, toluene, and hexanes. If immiscible, determine which layer is
the top layer in each case. Tabulate your findings.
2. Identify a recrystallization solvent: Test how suitable each of the following solvents are for recrystallizing
biphenyl: water, methanol, acetone, 95% ethanol, toluene, and hexanes. Tabulate your findings.
3. Hot filtration: Weigh about 0.5 g of crude biphenyl into an Erlenmeyer flask. Determine the exact mass
of impure biphenyl used. Add hot hexanes until no more solid dissolves and only solid impurities remain.
Filter the impurity using suction filtration into a 125 mL sidearm flask. Transfer the liquid into a small
beaker, and evaporate the hexanes by blowing nitrogen over the solution until only the partially purified
biphenyl is left.
Note: You MUST turn off the nitrogen tank BEFORE you leave the lab!!!!!!!!!
4. Recrystallization: Using the solvent you determined in step 2, barely cover the solid biphenyl in the hot
solvent. Be sure to maintain the temperature of the hot solvent while allowing the crystals to dissolve.
Add more of the hot solvent dropwise until the biphenyl is completely dissolved. Remove the flask from
the heat and allow to cool to room temperature. (Note: if you chose a low-boiling solvent, you will not
want to let it cool at r.t. for very long, as you will lose solvent due to evaporation). Place the flask in ice
to maximize recrystallized product.
5. Isolation: Isolate the recrystallized biphenyl by suction filtration. Use ice-cold recrystallization solvent
to rinse the flask and wash the recrystallized biphenyl. (Use a minimal amount! Why?) Pull air through
until the crystals are dry. Obtain a mass of recrystallized biphenyl and save it for next lab period in a
labeled container.
1
Purification of Biphenyl – Chromatography and Analysis
Assigned Reading: TLC: Zubrick, Chapter 27; Flash Chromatography: Zubrick, Chapter 28
Question: What is a good solvent system for purification of biphenyl from methyl orange dye by column
chromatography? Is column chromatography a more or less effective purification technique than
recrystallization for our impure biphenyl?
Procedure:
1. Thin Layer Chromatography In the first part of the lab, you will analyze a crude sample of biphenyl by TLC and
determine an appropriate solvent system for purification of biphenyl by column chromatography.
Devise your own procedure for this part, and make sure you do this before entering the lab (see Technique 18.7).
Determine Rf values for biphenyl and the impurity in each of the following solvent systems: 100% hexanes, 100%
ethyl acetate, and 4:1 hexanes:ethyl acetate. Together with your group, determine an appropriate column
chromatography solvent system.
2. Column Chromatography Using a long Pasteur pipet (220 mm), insert a plug of glass wool loosely, but firmly
in the tip of your pipette column. Fill the pipet column about 2/3 full with silica gel, then add eluent and allow
it to drain through the silica gel until it is evenly wet. Dissolve 50 mg of impure biphenyl in 2 drops of acetone
and apply them to the top of the column. Once the sample is drained onto the column, fill the pipet with eluent
solvent and collect four 1 mL fractions. Test for biphenyl in the fractions by running a TLC plate against authentic
biphenyl using the appropriate eluent solvent. If you see no biphenyl-containing fractions, or if your biphenyl is
still coming off the column (present in the 4th fraction), continue to elute and collect fractions.
Isolation of purified biphenyl For every fraction that contains only biphenyl, evaporate by pouring onto a preweighed watchglass in the hood. Once one fraction is evaporated, add the next pure fraction until all the
biphenyl is dry on the watchglass. Obtain a final mass of isolated biphenyl and calculate your percent recovery.
3. Melting point data Obtain three melting points: impure biphenyl, recrystallized biphenyl, and column
purified biphenyl. Record these in your notebook.
4. TLC data Spot a TLC plate with four lanes: authentic biphenyl, impure biphenyl, recrystallized biphenyl, and
column purified biphenyl. Develop the solvent in 4:1 hexanes/ethyl acetate. Visuallize the spots using UV light.
Draw your developed TLC plates in your notebook.
Waste
Solvent Waste:
Product Waste:
Pipette Waste:
2
Pre-Lab Assignment (20 points) -- This is ONE assignment in Gradescope
Recrystallization Pre-lab questions (10 points):
1. a. What is the chemical structure of biphenyl?
b. Is it polar or nonpolar? _______________________
c. What is its water solubility in g/L? __________________________
2. a. What is the chemical structure of methyl orange dye?
b. Is it polar or nonpolar? _______________________
c. What is its water solubility in g/L? __________________________
3. Provide the density of each of these solvents (you may look these up on Wikipedia, and you do not need
to include a reference):
water: ____________________g/mL
methanol: ____________________g/mL
acetone: ____________________g/mL
95% ethanol: ____________________g/mL
toluene: ____________________g/mL
hexanes: ____________________g/mL
3
Column Chromatography Pre-lab questions (10 points):
1. Are these techniques for purification or characterization: (1 point each)
a. column chromatography: ________________________________
b. TLC: ________________________________
c. melting point: ________________________________
2. a. How is TLC used to determine the purity of a sample? (1 point)
b. How is TLC useful in determining the identity of a sample? (1 point)
3. (1 point) Which of these solvent systems would cause a compound to elute from the column fastest (a,
b, or c)? (Circle the one correct answer.)
a. hexanes
b. 1:1 hexanes:ether
c. 1:1 ethyl acetate:acetone?
4. a. Why would a column be ineffective if you chose an eluting solvent that was too polar? (1 point)
b. Not polar enough? (1 point)
4
Post-Lab Assignment (20 points)
1. Results (10 points) Provide the following tabulated data:
1a. Miscibility tests
Solvent
miscible or immiscible? top layer?
methanol
acetone
95% ethanol
hexanes
toluene
1b. Identification of a recrystallization solvent. The exact procedure will differ among students, so you will need
to decide how to neatly organize your data.
1c. Purification results
Method
Solvent(s) mass recovered % recovery TLC analysis mp
Recrystallization
Column Chromatography
Team
1
Recrystallization
Column
2
Recrystallization
Column
3
Recrystallization
Column
4
Recrystallization
Column
5
Recrystallization
Column
6
Recrystallization
Column
mass recovered % recovery mp
5
1d. Draw the following TLC plates:
• TLC plate during column chromatography (each lane is a separate fraction, and the first lane is the crude)
•
TLC plate with four samples: authentic biphenyl, impure biphenyl, recrystallized biphenyl, and column
purified biphenyl
2. Discussion Questions (20 points): Compare and contrast the two purification methods by answering the
following questions. Reference the data you provided in question 1 to support your answer in each case.
2a. Which gave a higher percent recovery?
2b. Which gave a purer final sample?
2c. Which accommodated a larger sample?
2d. Which took longer?
6
2e. Are there any other considerations when choosing between recrystallization and column chromatography?
7