Communication Protocol for Grid-Connected Turnkey Station V1.3.3.0 Version Edited date V1.0.0 2019-2-26 V1.3.3.0 2019-4-15 Revised content and reasons Initial version Delete some protection parameters and add some country notes Valid for: SG3125HV-20, SG3125HV-MV-20, SG3400HV-20, SG3400HV-MV-20 1. Introduction This protocol is for communications between the grid-connected inverter of Sungrow and the background monitoring system. Modbus RTU/Modbus TCP (optional for Ethernet port) is used. According to this protocol, running data and fault state of the inverter can be read in real time. This protocol complies with the GB/T 19582-2008 standard. 2. Physical Interface (1) RS485 Default setting Address Inverter: 1 to 247 settable PC: 1 to 247 settable Broadcast Yes Baud rate 9600bit/s Check bit Null or settable Data bit 8 Stop bit 1 Mode RTU Electrical port RS485-2W cable connection (2). Ethernet: (optional, default IP: 192.168.13.127; subnet mask: 255.255.255.0; and port number: 502). 3. Communication Description (1). Data type: U16---16-bit unsigned integer, big-endian 1 / 17 S16---16-bit signed integer, big-endian U32---32-bit unsigned integer; little-endian for double-word data. Big-endian for byte data U32---32-bit signed integer; little-endian for double-word data. Big-endian for byte data For example: The transmission order of U16 data 0x0102 is 01, 02. For example, the transmission order of U32 data 0x01020304 is 03, 04, 01, 02 The transmission order of multibyte data UTF-8: the high-byte data is in the front and the low-byte data is at back. For example, the transmission order of the UTF-8 data "ABCD" is A, B, C, D. (2). Value descriptions The decimal parameters are transmitted as integer after expansion. For example, 10.333KW is transmitted as 10 333, and 800.5V is transmitted as 8005. Negative numbers are transmitted as complements, for example, 0xFFFF signifying -1. "Reserved" or unavailable register cannot be viewed or set. The return of unsigned numbers is "F", for example, "0xFFFF" is the return for U16, and "0xFFFFFFFF" is the return for U32; the return of signed numbers is the max. positive number, for example, "0x7FFF" for S16, "0x7FFFFFFF" for S32; and 0x00 for UTF-8. UTF-8 occupies 1 byte. The length of odd number is complemented by 0x00. (3). Address type Address of 3x type is of read-only register, supporting the cmdcode inquiry of 0x04. Address of 4x type is of holding register, supporting the cmdcode inquiry of 0x03, and cmdcodes writein of 0x10 and 0x06. Cmdcodes 0x10 and 0x06 support the broadcast address. Support Modbus error code 02 (address error), 04 (setting failure). Visit all registers by subtracting 1 from the register address. For example, if the address is 10000 to 10001, visit it using address 9999 10000. For example, "01 04 27 0F 00 02 + CRC" is used for querying address data 10000 to 10001. (4). Check type CRC16 generates polynomial 0xA001, little-endian. 4. Address Definition Table 4.1 Definition of running information variable address (Address type: 3X) No. Item Register Data address type Factor Unit Overall running information 1 Protocol number 15000 U32 2 Protocol version 15002 U32 3 SN serial 15004 U16*12 4 Machine type 15016 U16*13 5 Current of 1st input 15030 S16 0.1 A 6 Current of 2nd input 15031 S16 0.1 A 7 Current of 3rd input 15032 S16 0.1 A 8 Current of 4th input 15033 S16 0.1 A 9 Current of 5th input 15034 S16 0.1 A 10 Current of 6th input 15035 S16 0.1 A 11 Current of 7th input 15036 S16 0.1 A 2 / 17 Default value Note 12 Current of 8th input 15037 S16 0.1 A 13 Current of 9th input 15038 S16 0.1 A 14 Current of 10th input 15039 S16 0.1 A 15 Current of 11th input 15040 S16 0.1 A 16 Current of 12th input 15041 S16 0.1 A 17 Current of 13th input 15042 S16 0.1 A 18 Current of 14th input 15043 S16 0.1 A 19 Current of 15th input 15044 S16 0.1 A 20 Current of 16th input 15045 S16 0.1 A 21 Current of 17th input 15046 S16 0.1 A 22 Current of 18th input 15047 S16 0.1 A 23 Current of 19th input 15048 S16 0.1 A 24 Current of 20th input 15049 S16 0.1 A 25 Current of 21st input 15050 S16 0.1 A 26 Current of 22nd input 15051 S16 0.1 A 27 Current of 23rd input 15052 S16 0.1 A 28 Current of 24th input 15053 S16 0.1 A 29 Current of 25th input 15054 S16 0.1 A 30 Current of 26th input 15055 S16 0.1 A 31 Current of 27th input 15056 S16 0.1 A 32 Current of 28th input 15057 S16 0.1 A 33 Current of 29th input 15058 S16 0.1 A 34 Current of 30th input 15059 S16 0.1 A 35 Current of 31st input 15060 S16 0.1 A 36 Current of 32nd input 15061 S16 0.1 A SG3125HV:0x015E Device type code 15070 U16 SG3125HV-MV:0x015E 1 SG3400HV:0x3409 37 SG3400HV-MV:0x340A 38 Rated active power 15071 U16 0.1 39 Output type 15072 U16 1 40 Daily power yields 15073 U32 0.1 kWh 41 Monthly power yields 15075 U32 1 kWh 42 Total power yields 15077 U32 1 kWh 43 CO2 emission reduction 15079 U32 1 Kg 44 Daily grid-connection minutes kW 2: 3P3L Indicate the grid15081 U16 1 min connection hours of the current day 45 Total running hours 15082 U32 1 h 46 Total DC power 15092 U32 1 W 47 A-B line voltage 15094 U16 0.1 V 48 B-C line voltage 15095 U16 0.1 V 49 C-A line voltage 15096 U16 0.1 V 50 Phase A current 15097 U16 0.1 A 3 / 17 51 Phase B current 15098 U16 0.1 A 52 Phase C current 15099 U16 0.1 A 53 Total active power 15100 U32 1 W 54 Total reactive power 15102 S32 1 var 55 Total apparent power 15104 U32 1 VA 56 Power factor 15106 S16 0 57 Grid frequency 15107 U16 0.1 Hz 58 Rated reactive power 15108 U16 0.1 kvar 15109 U32 1 W 15111 S32 1 var 15113 S16 1 Power limitation actual value 59 feedback Reactive power adjustment 60 actual value feedback 61 Power factor feedback Refer to the appendix: Transformer node state Transformer node state 15114 U16 1 (only for devices equipped with 62 63 64 transformer) Annual power yields 15115 U32 1 Overall work state 15117 U32 1 kWh Refer to the appendix: Overall work state Only for devices Transformer oil temperature 15119 S16 0.1 ℃ 65 66 transformer Winding temperature 15120 S16 0.1 ℃ Running information of module 1 1 2 3 4 5 6 equipped with Daily power yields of module 1 Monthly power yields of module 1 Total power yields of module 1 Daily grid-connected minutes of module 1 Total running hours of module 1 Internal temperature of module 1 15150 U32 0.1 kWh 15152 U32 1 kWh 15154 U32 1 kWh 15156 U16 1 min 15157 U32 1 h 15159 S16 0.1 ℃ 7 DC voltage of module 1 15160 U16 0.1 V 8 DC current of module 1 15161 U16 0.1 A 9 DC power of module 1 15162 U32 1 W 10 A-B line voltage of module 1 15164 U16 0.1 V 11 B-C line voltage of module 1 15165 U16 0.1 V 4 / 17 Only for devices equipped with winding 12 C-A line voltage of module 1 15166 U16 0.1 V 13 Phase A current of module 1 15167 U16 0.1 A 14 Phase B current of module 1 15168 U16 0.1 A 15 Phase C current of module 1 15169 U16 0.1 A 16 Active power of module 1 15170 U32 1 W 17 Reactive power of module 1 15172 S32 1 var 18 Power factor of module 1 15174 S16 0 19 Grid frequency of module 1 15175 U16 0.1 Hz 20 Efficiency of module 1 15176 U16 0.1 % 21 State time of module 1: year 15178 U16 1 Fault time 15179 U16 1 Fault time 22 State time of module 1: month 23 State time of module 1: day 15180 U16 1 Fault time 24 State time of module 1: hour 15181 U16 1 Fault time 15182 U16 1 Fault time 15183 U16 1 Fault time 15185 U16 0.1 25 26 27 State time of module 1: minute State time of module 1: second Rated reactive power of module 1 kvar Refer to the appendix: 28 Fault state 1 of module 1 15186 U32 1 29 Fault state 2 of module 1 15188 U32 1 30 Node state 1 of module 1 15194 U32 1 31 Node state 2 of module 1 15196 U32 1 32 Temperature 1 of module 1 15198 S16 0.1 ℃ 33 Temperature 2 of module 1 15199 S16 0.1 ℃ 34 Temperature 3 of module 1 15200 S16 0.1 ℃ 35 Temperature 4 of module 1 15201 S16 0.1 ℃ 36 Temperature 5 of module 1 15202 S16 0.1 ℃ 37 Temperature 6 of module 1 15203 S16 0.1 ℃ 15204 U32 0.01 kΩ 15206 U32 0.01 kΩ 38 39 Positive resistance to ground of module 1 Negative resistance to ground of module 1 40 Work state of module 1 15208 U32 1 41 Alarm state of module 1 15210 U32 1 5 / 17 Fault state 1 Refer to the appendix: Fault state 2 Refer to the appendix: Node state 1 Refer to the appendix: Node state 2 Refer to the appendix: Module work state Refer to the appendix: Alarm state 1 42 43 44 Negative voltage to ground of module 1 Annual power yields of module 1 CO2 emission reduction of module 1 15212 S16 0.1 V 15213 U32 1 kWh 15215 U32 1 Kg Running information of module 2 1 2 3 4 5 6 Daily power yields of module 2 Monthly power yields of module 2 Total power yields of module 2 Daily grid-connected minutes of module 2 Total running hours of module 2 Internal air temperature of module 2 15270 U32 0.1 kWh 15272 U32 1 kWh 15274 U32 1 kWh 15276 U16 1 min 15277 U32 1 h 15279 S16 0.1 ℃ 7 DC voltage of module 2 15280 U16 0.1 V 8 DC current of module 2 15281 U16 0.1 A 9 DC power of module 2 15282 U32 1 W 10 A-B line voltage of module 2 15284 U16 0.1 V 11 B-C line voltage of module 2 15285 U16 0.1 V 12 C-A line voltage of module 2 15286 U16 0.1 V 13 Phase A current of module 2 15287 U16 0.1 A 14 Phase B current of module 2 15288 U16 0.1 A 15 Phase C current of module 2 15289 U16 0.1 A 16 Active power of module 2 15290 U32 1 W 17 Reactive power of module 2 15292 S32 1 var 18 Power factor of module 2 15294 S16 0 19 Grid frequency of module 2 15295 U16 0.1 Hz 15296 U16 0.1 % 15298 U16 1 Fault time 15299 U16 1 Fault time 20 21 22 Inverter efficiency of module 2 State time of module 2: year State time of module 2: month 23 State time of module 2: day 15300 U16 1 Fault time 24 State time of module 2: hour 15301 U16 1 Fault time 15302 U16 1 Fault time 15303 U16 1 Fault time 25 26 State time of module 2: minute State time of module 2: second 6 / 17 27 Rated reactive power of module 2 15305 U16 0.1 kvar Refer to the appendix: 28 Fault state 1 of module 2 15306 U32 1 29 Fault state 2 of module 2 15308 U32 1 30 Node state 1 of module 2 15314 U32 1 31 Node state 2 of module 2 15316 U32 1 32 Temperature 1 of module 2 15318 S16 0.1 ℃ 33 Temperature 2 of module 2 15319 S16 0.1 ℃ 34 Temperature 3 of module 2 15320 S16 0.1 ℃ 35 Temperature 4 of module 2 15321 S16 0.1 ℃ 36 Temperature 5 of module 2 15322 S16 0.1 ℃ 37 Temperature 6 of module 2 15323 S16 0.1 ℃ 15324 U32 0.01 kΩ 15326 U32 0.01 kΩ 38 39 Positive resistance to ground of module 2 Negative resistance to ground of module 2 Fault state 1 Refer to the appendix: Fault state 2 Refer to the appendix: Node state 1 Refer to the appendix: Node state 2 Refer to the appendix: 40 Work state of module 2 15328 U32 1 41 Alarm state of module 2 15330 U32 1 15332 S16 0.1 V 15333 U32 1 kWh 15335 U32 1 Kg 42 43 44 Negative voltage to ground of module 2 Annual power yields of module 2 CO2 emission reduction of module 2 Module work state Refer to the appendix: Alarm state 1 4.2 Definition of parameter setting address (Address type: 4X) No. 1 2 3 4 Item System clock: year System clock: month System clock: day System clock: hour Register Data Min. Max. Default address type value value value 15000 U16 1 2000 2038 15001 U16 1 1 12 15002 U16 1 1 31 15003 U16 1 0 23 Factor Unit 7 / 17 Note 5 6 System clock: minute System clock: second 15004 U16 1 0 59 15005 U16 1 0 59 0xCF (start)/0xCE 7 Start/Stop 15006 U16 1 0xCE 0xCF (stop)/others (no operation) 8 Remote emergency stop 0xCF (emergency 15007 U16 1 0xCE 0xCF stop)/others (no operation) Active 9 powerpercentage 15008 U16 0.1 % 0 1150 1100 setting 0: invalid; 1: valid 10 Local/Remote Control BIT 0: remote control 15010 U16 1 1 3 3 (default value is 1) BIT 1: local control (default value is 1) 0x55: OFF, power factor returns to 1; and reactive power percentage returns to 0 0xA1: power factor setting is valid, and reactive power percentage returns to 0 0xA2: Reactive power 11 Reactive power regulation switch percentage setting and 15011 U16 1 0x55 0xA5 0xA1 reactive power adjustment actual value setting valid, power factor returns to 1 0xA3—Q(U) mode setting is activated 0xA4: automatic voltage regulation setting is activated 0xA5—QP mode setting is activated 12 13 Reactive power percentage setting Power factor setting 15012 S16 0.1 % 15013 S16 0.001 8 / 17 -1045 1045 800 1000 -1000 -800 0 1000 Power limitation 14 actual value 15014 U16 0.1 kW 0 setting Reactive power 15 limitation actual Active power dispatch rise rate 34375 (rated (rated output output power power *1.15) *1.1) 21550 0 15015 S16 0.1 kvar value setting 16 35937 2155 0 15016 U16 0.01 %/s 1 10000 1000 15017 U16 0.01 %/s 1 10000 1000 15020 U16 1 s 0 600 0 15021 U16 0.1 %/s 1 1000 1000 15027 U16 0.01 %/s 1 10000 1000 15028 U16 0.01 %/s 1 10000 1000 15029 U16 0.1 % 0 1000 0 Active power 17 dispatch decline rate 18 19 20 Stop delay time (s) Stop slope Reactive power dispatch rise rate Reactive power 21 dispatch decline rate 22 Q(U) activation power point Genera 23 QU operation mode 15030 U16 1 0xA1 0xA3 l: 0xA1 India: 0xA3 0xA1: reactive power ratio mode; 0xA2: active power ratio mode: and 0xA3: power factor mode 0xB1: real-time voltage; 24 QU input voltage 15031 U16 1 0xB1 0xB2 0xB1 and 0xB2: record voltage Q(U) inductive 25 reactive power 15032 U16 0.1 % 0 1000 500 15033 U16 0.1 % 0 1000 500 limit value Q(U) capacitive 26 reactive power limit value Genera 27 Q(U) power factor end point 15034 U16 0 800 1000 l: 900 India: 950 Genera 28 Q(U) power factor start point 15035 U16 0.001 800 1000 l: 1000 India: 990 9 / 17 Genera l: 1080 29 Q(U) voltage rise start point 15037 U16 0.1 % 1000 1100 India: 1010 Brazil: 1000 Genera l: 1100 30 Q(U) voltage rise end point 15038 U16 0.1 % 1000 1100 India: 1050 Brazil: 1050 Genera l: 920 31 Q(U) voltage drop start point 15039 U16 0.1 % 900 1000 India: 990 Brazil: 1000 Genera l: 900 32 Q(U) voltage drop end point 15040 U16 0.1 % 900 1000 India: 950 Brazil: 950 Automatic voltage 33 regulation 15043 U16 1 % 90 110 100 15044 U16 1 % 0 10 1 15045 U16 0 900 1000 1000 15046 U16 0 900 1000 900 15047 U16 0.1 % 500 1000 1000 15048 U16 0.1 % 0 500 500 15060 U16 1 0x55 0xAA 0x55 0x55 0xAA 0x55 benchmark Automatic voltage 34 regulation hystersis (%) 35 36 37 38 39 Q(P) power factor upper limit Q(P) power factor lower limit Q(P) power upper limit Q(P) power lower limit DC switch close/open control 40 Night SVG switch 15061 U16 1 41 Start waiting time 15062 U16 1 1s 0 600 60 15063 U16 1 1s 20 600 60 42 Time for automatic 10 / 17 0xAA: open; 0x55: close 0xAA: enabled; 0x55: disabled recovery from fault 43 Reserved 15064 U16 44 Reserved 15065 U16 15066 U16 0.1 15069 U16 1 15070 U16 1 15071 U16 1 15072 U16 0.1 15073 U16 1 45 46 47 48 49 DC starting voltage Overall MPPT scanning enable Overall MPPT scanning period MPPT/CV mode switch CV mode voltage V 1mi n V 8000 13000 8400 0x55 0xAA 0x55 30 180 180 0x55 0xAA 0x55 800 1300 900 0x55 0xAA 0x55 Frequency 50 modulation function switch Frequency 51 regulation output change 15074 U16 1 0xA1 15075 U16 0.01 0xA2 0xA1 54 55 Overfrequency derating end point Overfrequency derating factor Overfrequency derating limit 15076 U16 0.01 15077 U16 0 15078 U16 0.1 5000 5500 5020 6000 6500 6020 5000 5500 5120 6000 6500 6120 0 2000 400 0 1150 300 Hz point 53 Hz % Frequency 56 regulation input 0xAA: CV mode; 0x55: MPPT mode 0xAA: enabled; 0x55: disabled 0xA2: power before derating Overfrequency derating start disabled 0xA1: rated power; benchmark 52 0xAA: enabled; 0x55: 50Hz grid Start point < end point 60Hz grid Start point < end point 50Hz grid Start point < end point 60Hz grid Start point < end point 0xB1: real-time 15079 U16 1 0xB1 0xB2 0xB2 type frequency 0xB2: record frequency Frequency 57 regulation 15080 U16 0.1 % 0 1150 0 4500 5000 4980 5500 6000 5980 4500 5000 4880 activation power 58 59 underfrequency rising start point underfrequency rising end point 15081 15082 U16 U16 0.01 0.01 Hz Hz 11 / 17 50Hz grid End point < start point 60Hz grid End point < start point 50Hz grid End point < start point 60 61 62 underfrequency rise factor Underfrequency rising limit Floating mode 5500 6000 5880 0 2000 0 0 1150 300 15083 U16 0.001 15084 U16 0.1 15168 U16 1 0x55 0xAA 0x55 15212 U16 1 0x55 0xAA 0x55 15213 U16 1 0x55 0xAA 0x55 % Active power 63 control closedloop switch Reactive power 64 control closedloop switch 5. Appendix Overall work state No. Item BIT Data range 1 Running BIT 0 1: Running 2 Stop BIT 1 1: Stop 3 Dry contact protection BIT 2 0: normal; 1: protection 4 Remote emergency stop BIT 3 0: normal; 1: protection 5 Door opening protection BIT 4 0: Disabled; 1: Enabled 6 Smoke protection BIT 5 0: normal; 1: protection 7 Reserved BIT6~BIT32 Note Reserved Fault state 1 No. Item BIT Data range 1 DC undervoltage BIT 0 0: normal/1: fault 2 DC overvoltage BIT 1 0: normal/1: fault 3 AC undervoltage BIT 2 0: normal/1: fault 4 AC overvoltage BIT 3 0: normal/1: fault 5 Underfrequency BIT 4 0: normal/1: fault 6 Overfrequency BIT 5 0: normal/1: fault 7 Contactor fault BIT 6 0: normal/1: fault 8 Islanding protection BIT 7 0: normal/1: fault 9 Sensor failure BIT 8 0: normal/1: fault 10 PDP protection BIT 9 0: normal/1: fault 11 Module overtemperature BIT 10 0: normal/1: fault 12 Reactor overtemperature BIT 11 0: normal/1: fault 13 Transformer overtemperature BIT 12 0: normal/1: fault 14 DC leakage current protection BIT 13 0: normal/1: fault 15 AC leakage current protection BIT 14 0: normal/1: fault 12 / 17 Note 60Hz grid End point < start point 0xAA: enabled; 0x55: disabled 0xAA: enabled; 0x55: disabled 0xAA: enabled; 0x55: disabled 16 Overload protection BIT 15 0: normal/1: fault 17 Reserved BIT 16 18 GFDI protection BIT 17 0: normal/1: fault 19 Fan fault BIT 18 0: normal/1: fault 20 DC fuse fault BIT 19 0: normal/1: fault 21 Detection fuse fault BIT 20 0: normal/1: fault 22 DC overcurrent BIT 21 0: normal/1: fault 23 AC overcurrent BIT 22 0: normal/1: fault 24 Frequency abnormal BIT 23 0: normal/1: fault 25 Temperature abnormal BIT 24 0: normal/1: fault 26 Hardware fault BIT 25 0: normal/1: fault 27 Grounding fault BIT 26 0: normal/1: fault 28 Bus overvoltage BIT 27 0: normal/1: fault 29 Bus undervoltage BIT 28 0: normal/1: fault 30 Inverter overvoltage BIT 29 0: normal/1: fault 31 Reserved BIT 30 0: normal/1: fault 32 Reserved BIT 31 0: normal/1: fault Fault state 2 No. Item BIT Data range 1 Insulation impedance BIT 0 0: normal/1: fault 2 (AC) SPD fault BIT 1 0: normal/1: fault 3 Sampling fault BIT 2 0: normal/1: fault 4 (PV) polarity reversed BIT 3 0: normal/1: fault BIT 4 0: normal/1: fault BIT 5 0: normal/1: fault 5 6 Control power supply abnormal Backup power supply abnormal 7 (AC) current unbalance BIT 6 0: normal/1: fault 8 AC fuse fault BIT 7 0: normal/1: fault 9 (DC) SPD fault BIT 8 0: normal/1: fault 10 Buffer contactor fault BIT 9 0: normal/1: fault 11 DC injection fault BIT 10 0: normal/1: fault 12 DC switch fault BIT 11 0: normal/1: fault 13 Device code repeat fault BIT 12 0: normal/1: fault BIT 13 0: normal/1: fault BIT 14 0: normal/1: fault 14 15 Parallel operation communication fault Control cabinet temperature abnormal 16 DC fuse grounding fault BIT 15 0: normal/1: fault 17 Reversed branch over-current BIT 16 0: normal/1: fault 18 Grid voltage unbalance BIT 17 0: normal/1: fault 19 Reserved BIT 18~BIT 19 0: normal/1: fault 13 / 17 Note 20 AC cabinet over-temperature BIT 20 0: normal/1: fault 21 AC switch disconnection BIT 21 0: normal/1: fault 22 AC switch fault BIT 22 0: normal/1: fault 23 Soft start fault BIT 23 0: normal/1: fault 24 DC voltage sampling fault BIT 24 0: normal/1: fault 25 Fan 2 fault BIT 25 0: normal/1: fault 26 Current unbalance 2 BIT 26 0: normal/1: fault 27 Current unbalance 3 BIT 27 0: normal/1: fault 28 Drive board fault BIT 28 0: normal/1: fault 29 DC cabinet over-temperature BIT 29 0: normal/1: fault 30 Neutral point potential shift BIT 30 0: normal/1: fault 31 Carrier sync fault BIT 31 0: normal/1: fault Alarm state 1 No. Item BIT Data range 1 Temperature abnormal alarm BIT 0 0: normal/1: alarm 2 Low insulation resistance BIT 1 0: normal/1: alarm 3 GFRT operation BIT 2 0: normal/1: alarm 4 CT unbalance BIT 3 0: normal/1: alarm 5 DC fuse abnormal BIT 4 0: normal/1: alarm BIT 5 0: normal/1: alarm 6 DSP-MDC communication abnormal 7 DC sensor abnormal BIT 6 0: normal/1: alarm 8 DC SPD alarm BIT 7 0: normal/1: alarm 9 AC SPD alarm BIT 8 0: normal/1: alarm BIT 9 0: normal/1: alarm 10 Bypass circuit breaker abnormal 11 Bypass fuse abnormal BIT 10 0: normal/1: alarm 12 Ground fuse abnormal BIT 11 0: normal/1: alarm 13 DC switch abnormal BIT 12 0: normal/1: alarm BIT 13 0: normal/1: alarm BIT 14 0: normal/1: alarm BIT 15 0: normal/1: alarm BIT 16 0: normal/1: alarm BIT 17 0: normal/1: alarm BIT 18 0: normal/1: alarm BIT 19 0: normal/1: alarm BIT 20 0: normal/1: alarm 14 15 16 17 18 19 20 21 Anti-PID power supply abnormal Fan abnormal External power supply abnormal DC bypass forward overcurrent alarm DC bypass reserve overcurrent alarm Tributary board communication error AC circuit breaker abnormal Energy meter communication abnormal 14 / 17 Note Abnormal communication between DSP and meter plate 22 Fan 2 anomaly BIT 21 0: normal/1: alarm 23 Contactor contact abnormal BIT 22 0: normal/1: alarm BIT 23 0: normal/1: alarm BIT 24 0: normal/1: alarm BIT 25 0: normal/1: alarm BIT 26 0: normal/1: alarm 24 25 26 27 Temperature & humidity board communication error Frequency deviation active power regulation Voltage deviation reactive power regulation Insulation board communication anomaly Node state No. Item BIT Data range 1 AC circuit breaker state BIT 0 2 AC main contactor state BIT 1 3 ABC fault state BIT 12 0: normal/1: fault 4 ABC remote/local BIT 13 0: local/1: remote 5 AC fuse status BIT 16 Note 0: disconnected/1: connected 0: disconnected/1: connected 0: disconnected/1: connected Node state 2 No. 1 2 3 4 5 Item BIT SPD node state BIT 12 DC switch state 1 BIT 20 DC switch state 2 BIT 21 DC switch state 3 BIT 22 DC switch state 4 BIT 23 Data range Note 0: disconnected/1: connected 0: disconnected/1: connected 0: disconnected/1: connected 0: disconnected/1: connected 0: disconnected/1: connected Module work state No. Item BIT Data range 1 Running BIT 0 1: running 2 Stop BIT 1 1: Stop 3 Initial standby BIT 2 1: initial standby 4 Key stop BIT 3 1: Key stop 5 Standby BIT 4 1: Standby 6 Emergency stop BIT 5 1: Emergency stop 7 Starting BIT 6 1: being started up 8 Stopping BIT 7 1: Being stopped 15 / 17 Note normal stop 9 Reserved BIT 8 10 Fault stop BIT 9 1: fault stands Alarm running BIT 10 1: alarm running Derating running BIT 11 1: derating running Reserved BIT 12 11 12 13 IO-DSP communication BIT 13 14 abnormal 15 Reserved BIT 14 16 Reserved BIT 15 17 Reserved BIT 16 18 Total signal bit of the running BIT 17 Dispatch derating, where dispatch value is less than 100%. 1: communication Abnormal communication between abnormal SCU and DSP 0: stop/1: running Including all running states: state bit0: running; bit7: being stopped; bit10: alarm running; bit11: derating running 19 Total stop bit BIT 18 0: running/1: stop Including all non-running states BIT 1: stop; BIT 2: initial standby; BIT 3: key stop; BIT 4: standby; BIT 5: emergency stop; BIT 6: being started up: BIT 9: fault stands; BIT13: IODSP communication abnormity; and BIT 19: anti-PID running 20 Anti-PID running IO-MDC communication 21 abnormal BIT 19 BIT 20 1: anti-PID running 1: Communication Abnormal communication between abnormal SCU and meter plate Transformer node state No. Item BIT Data range 1 Heavy gas tripping BIT 0 0: open/1: close 2 Heavy gas alarm BIT 1 0: normal/1: alarm 3 Transformer oil temperature BIT 2 0: normal/1: alarm BIT 3 0: open/1: close alarm 4 Transformer oil temperature tripping 5 Low oil level tripping BIT 4 0: open/1: close 6 Low oil level alarm BIT 5 0: normal/1: alarm 7 Pressure relief valve tripping BIT 6 0: open/1: close 8 Pressure relief valve alarm BIT 7 0: normal/1: alarm 9 Load switch node 1 of BIT 8 0: disconnected/1: switchgear 10 Load switch node 2 of switchgear connected BIT 9 0: disconnected/1: connected 16 / 17 Note 11 BIT 10 Circuit breaker node 12 connected BIT 11 Disconnector node 13 Overcurrent protection 0: disconnected/1: 0: disconnected/1: connected BIT 12 0: normal/1: protection signal/tripping signal 17 / 17
0
You can add this document to your study collection(s)
Sign in Available only to authorized usersYou can add this document to your saved list
Sign in Available only to authorized users(For complaints, use another form )