Specification for Unbonded Flexible Pipe API SPECIFICATION 17J FIFTH EDITION, MAY 2024 API MONOGRAM PROGRAM EFFECTIVE DATE: MAY 29, 2025 Special Notes API publications necessarily address problems of a general nature. With respect to particular circumstances, local, state, and federal laws and regulations should be reviewed. The use of API publications is voluntary. In some cases, third parties or authorities having jurisdiction may choose to incorporate API standards by reference and may mandate compliance. Neither API nor any of API’s employees, subcontractors, consultants, committees, or other assignees make any warranty or representation, either express or implied, with respect to the accuracy, completeness, or usefulness of the information contained herein, or assume any liability or responsibility for any use, or the results of such use, of any information or process disclosed in this publication. Neither API nor any of API's employees, subcontractors, consultants, or other assignees represent that use of this publication would not infringe upon privately owned rights. API publications may be used by anyone desiring to do so. Every effort has been made by the Institute to assure the accuracy and reliability of the data contained in them; however, the Institute makes no representation, warranty, or guarantee in connection with this publication and hereby expressly disclaims any liability or responsibility for loss or damage resulting from its use or for the violation of any authorities having jurisdiction with which this publication may conflict. API publications are published to facilitate the broad availability of proven, sound engineering and operating practices. These publications are not intended to obviate the need for applying sound engineering judgment regarding when and where these publications should be utilized. The formulation and publication of API publications is not intended in any way to inhibit anyone from using any other practices. Any manufacturer marking equipment or materials in conformance with the marking requirements of an API standard is solely responsible for complying with all the applicable requirements of that standard. API does not represent, warrant, or guarantee that such products do in fact conform to the applicable API standard. All rights reserved. No part of this work may be reproduced, translated, stored in a retrieval system, or transmitted by any means, electronic, mechanical, photocopying, recording, or otherwise, without prior written permission from the publisher. Contact the Publisher, API Publishing Services, 200 Massachusetts Avenue NW, Suite 1100, Washington, DC 20001. Copyright © 2024 American Petroleum Institute Foreword Nothing contained in any API publication is to be construed as granting any right, by implication or otherwise, for the manufacture, sale, or use of any method, apparatus, or product covered by letters patent. Neither should anything contained in the publication be construed as insuring anyone against liability for infringement of letters patent. The verbal forms used to express the provisions in this document are as follows. Shall: As used in a standard, “shall” denotes a minimum requirement in order to conform to the standard. Should: As used in a standard, “should” denotes a recommendation or that which is advised but not required in order to conform to the standard. May: As used in a standard, “may” denotes a course of action permissible within the limits of a standard. Can: As used in a standard, “can” denotes a statement of possibility or capability. This document was produced under API standardization procedures that ensure appropriate notification and participation in the developmental process and is designated as an API standard. Questions concerning the interpretation of the content of this publication or comments and questions concerning the procedures under which this publication was developed should be directed in writing to the Director of Standards, American Petroleum Institute, 200 Massachusetts Avenue NW, Suite 1100, Washington, DC 20001. Requests for permission to reproduce or translate all or any part of the material published herein should also be addressed to the director. Generally, API standards are reviewed and revised, reaffirmed, or withdrawn at least every five years. A one-time extension of up to two years may be added to this review cycle. Status of the publication can be ascertained from the API Standards Department, telephone (202) 682-8000. A catalog of API publications and materials is published annually by API, 200 Massachusetts Avenue NW, Suite 1100, Washington, DC 20001. Suggested revisions are invited and should be submitted to the Standards Department, API, 200 Massachusetts Avenue NW, Suite 1100, Washington, DC 20001, standards@api.org. Contents Page 1 Scope...................................................................................................................................................... 1 2 Normative References .......................................................................................................................... 1 3 3.1 3.2 Terms, Definitions, Acronyms, Abbreviations, and Symbols .......................................................... 5 Terms and Definitions .......................................................................................................................... 5 Acronyms, Abbreviations, and Symbols .......................................................................................... 15 4 4.1 4.2 4.2.1 4.2.2 4.3 4.4 4.4.1 4.4.2 4.4.3 4.4.4 4.5 4.6 4.6.1 4.6.2 Functional Requirements ................................................................................................................... 18 General ................................................................................................................................................. 18 Overall Requirements ......................................................................................................................... 18 Flexible Pipe ........................................................................................................................................ 18 End Fitting ........................................................................................................................................... 18 General Design Parameters ............................................................................................................... 18 Internal Fluid Parameters ................................................................................................................... 19 General ................................................................................................................................................. 19 Internal Pressure Definitions ............................................................................................................. 19 Temperature Definitions ..................................................................................................................... 22 Fluid Composition............................................................................................................................... 22 External Environment ......................................................................................................................... 23 System Requirements ........................................................................................................................ 24 Minimum System Requirements ....................................................................................................... 24 Flowline and Riser Parameters .......................................................................................................... 27 5 5.1 5.2 5.3 5.4 Design Requirements ......................................................................................................................... 28 Loads and Load Effects...................................................................................................................... 28 Pipe Design Methodology .................................................................................................................. 36 Flexible Pipe Design ........................................................................................................................... 37 System Design Requirements ........................................................................................................... 50 6 6.1 6.2 6.3 Materials ............................................................................................................................................... 55 Material Requirements........................................................................................................................ 55 Testing Requirements ........................................................................................................................ 61 Quality Assurance Requirements ..................................................................................................... 71 7 7.1 7.2 7.3 7.4 7.5 7.6 7.7 7.8 7.9 Manufacturing Requirements ............................................................................................................ 73 Quality Assurance Requirements ..................................................................................................... 73 Carcass ................................................................................................................................................ 75 Polymer Extrusions ............................................................................................................................ 75 Pressure and Tensile Armor Layers ................................................................................................. 77 Antiwear, Insulation, and Anti-buckling Tape Layers ..................................................................... 78 End Fitting ........................................................................................................................................... 79 Processes Requiring Validation ........................................................................................................ 81 Manufacturing Tolerances ................................................................................................................. 83 Repairs ................................................................................................................................................. 83 8 8.1 8.2 8.3 8.4 8.5 8.6 8.7 8.8 8.9 Documentation .................................................................................................................................... 84 General ................................................................................................................................................. 84 Design Premise ................................................................................................................................... 85 Design Load Report ............................................................................................................................ 85 Design Report...................................................................................................................................... 86 Pipe Datasheet .................................................................................................................................... 87 Manufacturing Quality Plan ............................................................................................................... 88 Fabrication Specification ................................................................................................................... 88 As-built Documentation...................................................................................................................... 88 Operation Manual ................................................................................................................................ 89 9 9.1 9.2 9.3 9.4 9.5 9.6 9.7 Factory Acceptance Tests (FATs) ..................................................................................................... 91 General ................................................................................................................................................. 91 Gauge Test ........................................................................................................................................... 91 Hydrostatic Pressure Test ................................................................................................................. 92 Electrical Continuity and Electrical Isolation Tests ........................................................................ 93 Gas-venting System Test ................................................................................................................... 93 Annulus Sealing Test.......................................................................................................................... 94 End Fitting Sealing Test ..................................................................................................................... 95 10 10.1 10.2 Marking and Packaging ...................................................................................................................... 96 Marking ................................................................................................................................................ 96 Packaging ............................................................................................................................................ 96 11 11.1 11.2 11.3 Requirements for Independent Review and Certification ............................................................... 97 General ................................................................................................................................................. 97 Type Approval Certification Process ................................................................................................ 97 Project Certification Process ........................................................................................................... 102 Annex A (informative) Purchasing Guidelines............................................................................................ 105 Annex B (informative) Flexible Pipe Datasheet .......................................................................................... 112 Bibliography ................................................................................................................................................... 113 Figures 1 Internal Pressure Definitions ............................................................................................................. 20 2 Flexible Pipe Certification Scheme ................................................................................................... 97 Tables 1 Internal Fluid Parameters ................................................................................................................... 19 2 Internal Pressure Definitions ............................................................................................................. 21 3 Temperature Definitions ..................................................................................................................... 22 4 External Environment Parameters .................................................................................................... 23 5 Flowline and Riser Parameters .......................................................................................................... 30 6 Load Combinations of Load Classes, Load Conditions ................................................................. 31 7 Typical Load Classes.......................................................................................................................... 32 8 Flexible Pipe Layer Design Criteria ................................................................................................... 33 9 Annulus Classification and Associated Design Requirements ..................................................... 34 10 Minimum Bend Radius Design Criteria............................................................................................. 39 11 End Fitting Permissible Utilization Factors ...................................................................................... 46 12 System-related Pipe Design Requirements ..................................................................................... 51 13 Property Requirements for Polymer Materials ................................................................................ 57 14 Property Requirements for Metallic Wire and Strip Materials and Weldments ............................ 58 15 Property Requirements for Anti-buckling Tapes ............................................................................. 61 16 Test Procedures for Extruded Polymer (Including Antiwear Layers and Insulation) and Anti-buckling Layer Materials ............................................................................................................ 64 17 Test Procedures for Metallic Materials (Carcass Strip, Carcass Insert, Pressure Armor, and Tensile Armor Wires) and Weldments ....................................................................................... 67 18 Minimum Raw Material Quality Control Test Requirements........................................................... 71 19 Requirements of Material Specifications.......................................................................................... 73 20 Documentation Requirements for the Design Premise .................................................................. 85 21 Factory Acceptance Test ................................................................................................................... 91 A.1 Flexible Pipe Purchasing Guidelines .............................................................................................. 105 B.1 Flexible Pipe Datasheet Minimum Requirements .......................................................................... 112 Specification for Unbonded Flexible Pipe 1 Scope API 17J defines the technical requirements for safe, dimensionally and functionally interchangeable flexible pipes that are designed and manufactured to uniform standards and criteria. Minimum requirements are specified for the design, material selection, manufacture, testing, marking, and packaging of flexible pipes, with reference to existing codes and standards where applicable. See API 17B for guidelines on the use of flexible pipes. API 17J applies to unbonded flexible pipe assemblies, consisting of segments of flexible pipe body with end fittings attached to both ends. API 17J does not cover flexible pipes of bonded structure. API 17J does not apply to flexible pipe ancillary components. Bonded flexible pipes are covered in API 17K. Ancillary equipment is covered in API 17L1 and API 17L2. API 17J does not apply to flexible pipes that include nonmetallic tensile and pressure armor wires and structural composite layers. The applications addressed by API 17J are sweet and sour service production, including export and injection applications. Production products include oil, gas, water, and injection chemicals. API 17J applies to both static and dynamic flexible pipes used as flowlines, risers, and jumpers. API 17J does not apply to flexible pipes for use in choke and kill line applications. NOTE 1 See API 16C for choke and kill line applications. NOTE 2 API 17J also applies to unbonded flexible pipes used for carbon capture, transportation, and storage applications. 2 Normative References The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. API Specification 6A, Specification for Wellhead and Tree Equipment API Recommended Practice 17B, Recommended Practice for Flexible Pipe, 6th Edition API Specification 17D, Specification for Subsea Wellhead and Tree Equipment API Technical Report 17TR1, Evaluation Standard for Internal Pressure Sheath Polymers for High Temperature Flexible Pipes API Standard 20S, Additively Manufactured Metallic Components for Use in the Petroleum and Natural Gas Industries ANSI 1 /NACE 2 MR0175/ISO 3 15156, Petroleum and natural gas industries—Materials for use in H2S-containing environments in oil and gas production 1 2 3 American National Standards Institute, 25 West 43rd Street, 4th Floor, New York, NY 10036, www.ansi.org. Formerly NACE International, now known as The Association for Materials Protection and Performance (AMPP), 15835 Park Ten Place, Houston, TX 77084, www.ampp.org/home. International Organization for Standardization, Chemin de Blandonnet 8, CP 401, 1214 Vernier, Geneva, Switzerland, www.iso.org. 2 API SPECIFICATION 17J ANSI/NACE TM0177, Laboratory Testing of Metals for Resistance to Sulfide Stress Cracking and Stress Corrosion Cracking in H2S Environments ASME Boiler and Pressure Vessel Code 4, Section IX: Welding, Brazing Qualifications ASTM A29/A29M 5, Standard Specification for General Requirements for Steel Bars, Carbon and Alloy, Hot-Wrought ASTM A182/A182M, Standard Specification for Forged or Rolled Alloy and Stainless Steel Pipe Flanges, Forged Fittings, and Valves and Parts for High-Temperature Service ASTM A480/A480M, Standard Specification for General Requirements for Flat-Rolled Stainless and Heat-Resisting Steel Plate, Sheet, and Strip ASTM A668/A668M, Standard Specification for Steel Forgings, Carbon and Alloy, for General Industrial Use ASTM A694, Standard Specification for Carbon and Alloy Steel Forgings for Pipe Flanges, Fittings, Valves, and Parts for High-Pressure Transmission Service ASTM A751, Standard Test Methods and Practices for Chemical Analysis of Steel Products ASTM C177, Standard Test Method for Steady-State Heat Flux Measurements and Thermal Transmission Properties by Means of the Guarded-Hot-Plate Apparatus ASTM C518, Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus ASTM D256, Standard Test Methods for Determining the Izod Pendulum Impact Resistance of Plastics ASTM D638, Standard Test Method for Tensile Properties of Plastics ASTM D664, Standard Test Method for Acid Number of Petroleum Products by Potentiometric Titration ASTM D695, Standard Test Method for Compressive Properties of Rigid Plastics ASTM D792, Standard Test Methods for Density and Specific Gravity (Relative Density) of Plastics by Displacement ASTM D882, Standard Test Method for Tensile Properties of Thin Plastic Sheeting ASTM D974, Standard Test Method for Acid and Base Number by Color-Indicator Titration ASTM D1044, Standard Test Method for Resistance of Transparent Plastics to Surface Abrasion by the Taber Abraser ASTM D1141, Standard Practice of the Preparation of Substitute Ocean Water ASTM D1238, Standard Test Method for Melt Flow Rates of Thermoplastics by Extrusion Plastometer ASTM D1418, Standard Practice for Rubber and Rubber Latices—Nomenclature ASTM D1505, Standard Test Method for Density of Plastics by the Density-Gradient Technique 4 5 ASME International, 2 Park Avenue, New York, NY 10016-5990, www.asme.org. ASTM International, 100 Barr Harbor Drive, West Conshohocken, PA 19428, www.astm.org. SPECIFICATION FOR UNBONDED FLEXIBLE PIPE 3 ASTM D2990, Standard Test Methods for Tensile, Compressive, and Flexural Creep and Creep-Rupture of Plastics ASTM D3410, Standard Test Method for Compressive Properties of Polymer Matrix Composite Materials with Unsupported Gage Section by Shear Loading ASTM D3759, Standard Test Method for Breaking Strength and Elongation of Pressure-Sensitive Tape ASTM D4060, Standard Test Method for Abrasion Resistance of Organic Coatings by the Taber Abraser ASTM D5028, Standard Test Method for Curing Properties of Pultrusion Resins by Thermal Analysis ASTM D6869, Standard Test Method for Coulometric and Volumetric Determination of Moisture in Plastics Using the Karl Fischer Reaction (the Reaction of Iodine with Water) ASTM E328, Standard Test Methods for Stress Relaxation for Materials and Structures ASTM E384, Standard Test Method for Microindentation Hardness of Materials ASTM E831, Standard Test Method for Linear Thermal Expansion of Solid Materials by Thermomechanical Analysis ASTM E1269, Standard Test Method for Determining Specific Heat Capacity by Differential Scanning Calorimetry ASTM E1356, Standard Test Method for Assignment of the Glass Transition Temperatures by Differential Scanning Calorimetry ASTM E1640, Standard Test Method for Assignment of the Glass Transition Temperature By Dynamic Mechanical Analysis ASTM E2602, Standard Test Methods for Assignment of the Glass Transition Temperature by Modulated Temperature Differential Scanning Calorimetry ASTM G48-03, Standard Test Methods for Pitting and Crevice Corrosion Resistance of Stainless Steels and Related Alloys by Use of Ferric Chloride Solution DNV-RP-0034, Steel forgings for subsea application—technical requirements DNV-RP-F204 6, Riser Fatigue DNV-RP-O501, Managing sand production and erosion DNV-ST-B203, Additive manufacturing of metallic parts EN 10204:2004 7, Metallic products—Types of inspection documents IOGP S-563 8, Piping & Valve Components—Material Data Sheets ISO 148-1, Metallic materials—Charpy pendulum impact test—Part 1: Test method ISO 179 (all parts), Plastics—Determination of Charpy impact properties 6 7 8 DNV, Veritasveien 1, 1363 Hovik, Norway, www.dnv.com. European Committee for Standardization (CEN-CENELEC), Rue de la Science 23, B-1040 Brussels, Belgium, www.cencenelec.eu. International Oil & Gas Producers, City Tower, 40 Basinghall Street, London, EC2V 5DE, www.iogp.org. 4 API SPECIFICATION 17J ISO 307, Plastics—Polyamides—Determination of viscosity number ISO 527-1, Plastics—Determination of tensile properties—Part 1: General principles ISO 527-2, Plastics—Determination of tensile properties—Part 2: Test conditions for moulding and extrusion plastics ISO 527-3, Plastics—Determination of tensile properties— Part 3: Test conditions for films and sheets ISO 604, Plastics—Determination of compressive properties ISO 899-1, Plastics—Determination of creep behaviour—Part 1: Tensile creep ISO 1133-2:2011, Plastics—Determination of the melt mass-flow rate (MFR) and the melt volume flow rate (MVR) of thermoplastics—Part 2: Method for materials sensitive to time temperature history and/or moisture ISO 1183-1, Plastics—Methods for determining the density of non-cellular plastics—Part 1: Immersion method, liquid pycnometer method and titration method ISO 3384-1, Rubber, vulcanized or thermoplastic—Determination of stress relaxation in compression—Part 1: Testing at constant temperature ISO 4892-2, Plastics—Methods of exposure to laboratory light sources—Part 2: Xenon-arc lamps ISO 6506-1, Metallic materials—Brinell hardness test—Part 1: Test method ISO 6507-1, Metallic materials—Vickers hardness test—Part 1: Test method ISO 6508-1, Metallic materials—Rockwell hardness test—Part 1: Test method ISO 6892-1, Metallic materials—Tensile testing at ambient temperature—Part 1: Method of test at room temperature ISO 8301, Thermal insulation—Determination of steady-state thermal resistance and related properties— Heat flow meter apparatus ISO 8302, Thermal insulation—Determination of steady-state thermal resistance and related properties— Guarded hot plate apparatus ISO 9352, Plastics—Determination of resistance to wear by abrasive wheels ISO 10474:1991, Steel and steel products—Inspection documents ISO 11357-1, Plastics—Differential scanning calorimetry (DSC)—Part 1: General principles ISO 11357-2, Plastics – Differential scanning calorimetry (DSC) – Part 2: Determination of glass transition temperature and step height ISO 11357-4, Plastics—Differential scanning calorimetry (DSC)—Part 4: Determination of specific heat capacity ISO 11359-2, Plastics—Thermomechanical analysis (TMA)—Part 2: Determination of coefficient of linear thermal expansion and glass transition temperature ISO 13703-2, Oil and gas industries including lower carbon energy—Piping systems on offshore platforms and onshore plants—Part 2: Materials SPECIFICATION FOR UNBONDED FLEXIBLE PIPE 5 ISO 13847, Petroleum and natural gas industries—Pipeline transportation systems—Welding of pipelines ISO 15614-1, Specification and qualification of welding procedures for metallic materials—Welding procedure test—Part 1: Arc and gas welding of steels and arc welding of nickel and nickel alloys ISO 16120-4, Non-alloy steel wire rod for conversion to wire – Part 4: Specific requirements for wire rod for special applications ISO 22088, Plastics – Determination of resistance to environmental stress cracking (ECSC) – Part 3: Bent strip method ISO 23936-1, Oil and gas industries including lower carbon energy—Non-metallic materials in contact with media related to oil and gas production—Part 1: Thermoplastics ISO 23936-2, Oil and gas industries including lower carbon energy—Non-metallic materials in contact with media related to oil and gas production—Part 2: Elastomers NACE TM0284, Evaluation of Pipeline and Pressure Vessel Steels for Resistance to Hydrogen-Induced Cracking NACE TM0316, Four-Point Bend Testing of Materials for Oil and Gas Application 3 Terms, Definitions, Acronyms, Abbreviations, and Symbols 3.1 Terms and Definitions For the purposes of this document, the following terms and definitions apply. 3.1.1 ancillary components Components that are attached to the flexible pipe in order to perform one or more of the following functions: a) to control the flexible pipe behavior; b) to provide a structural transition between the flexible pipe and adjacent structures; c) to avoid excessive curvature; d) to attach other structures to the flexible pipe, or the flexible pipe to other structures, or to connect flanges or proprietary connectors to the flexible pipe (e.g. stud bolts and nuts and clamps); e) to protect or repair the flexible pipe; f) to provide a seal between the flexible pipe and an I-tube or J-tube inner wall (in order to prevent corrosion inhibited seawater escaping). 3.1.2 annulus Space between two extruded polymer layers, e.g. the internal pressure sheath and external sheath that is sealed in the end fitting. 3.1.3 anti-buckling tape A polymer, fabric, wire, fiber, or other reinforcement wound around the tensile armors, compressing the wires/strips against the pipe body to resist radial buckling of these wires/strips. 6 API SPECIFICATION 17J 3.1.4 antiwear layer Nonmetallic layer, either extruded thermoplastic sheath or tape wrapping, normally used to minimize wear between structural layers in dynamic application. 3.1.5 batch of steel wires/strip An amount of steel wires/strip originating from the same cast, formed into shape successively within the tolerance given in the purchasing specification and heat treated in the same oven charge or in the same in-line setup sequence. 3.1.63.1 bellmouth Part of a guide tube, formed in the shape of a bellmouth, and designed to prevent overbending of the flexible pipe. 3.1.7 bend radius Radius of curvature of the flexible pipe measured from the pipe centerline. NOTE Storage minimum bend radius (SR) and operating minimum bend radius (MBR) are defined in 5.3.1. 3.1.8 bend restrictor Mechanical device that functions as a mechanical stop and limits the local radius of curvature of the flexible pipe to a minimum value. 3.1.9 bend stiffener Integrated or standalone component that locally supports the pipe to limit bending stresses and curvature of the pipe to acceptable levels. 3.1.10 bending stiffness The resistance to bending from an applied bending moment—product of the effective elastic modulus and moment of inertia of the flexible pipe. The bending stiffness may vary with tension, temperature across the pipe layers, bore pressure, dry/flooded annulus pressure, and external pressure. 3.1.11 birdcaging One mode of radial buckling of the tensile armor wires, usually caused by extreme axial compression (such as reverse end cap loading) and associated with loss of support (external sheath damage or anti-buckling tapes failure), which results in radial deformation. 3.1.12 bonded flexible pipe Flexible pipe in which the metallic or nonmetallic reinforcement is integrated and bonded to a vulcanized elastomeric material, where textile material is included in the structure to obtain additional structural reinforcement or to separate elastomeric layers. 3.1.13 buckling of tensile armors Buckling of the tensile armors in the radial (birdcaging) or lateral direction (lateral buckling) caused by axial compression (true wall compression), associated or not with pipe bending, twist, or torsion and affected by the annulus condition (flooded or dry). SPECIFICATION FOR UNBONDED FLEXIBLE PIPE 7 3.1.14 burst disk Weak points in the outer sheath designed to burst when the gas pressure in the annulus exceeds a specified value. NOTE The weak point is induced by reducing the thickness of the sheath over a localized area. 3.1.15 carcass Interlocked metallic construction that is used as the innermost layer in rough bore pipes to prevent, totally or partially, collapse of the internal pressure sheath or pipe due to pipe depressurization, external pressure, tensile armor pressure, and mechanical crushing loads. NOTE The carcass may be used externally to protect the surface of the pipe against abrasion from external environment, dropped object, or fire. 3.1.16 carcass insert An addition to a conventional rough bore (agraff) carcass that shields the internal corrugations from the main flow path. 3.1.17 carcass join-up weld A connection of two completed carcass sections. 3.1.18 carcass strip weld A connection of the strip (or insert) the carcass is made from. 3.1.19 certification The process of confirming through the review of documented evidence and witnessing of activities that a technology or product complies with the requirements of its applicable standard or project-specific application, respectively. 3.1.20 certificate of conformity COC Document established by an independent verification agent (IVA) within the context of a project certification process, certifying that a flexible pipe including end fittings has been manufactured and designed in accordance with API 17J requirements as well as purchaser requirements. 3.1.21 choke and kill line Flexible pipe jumper located between a marine drilling riser steel choke line and kill line and blowout preventer. 3.1.22 connector Device used to provide a leak-tight structural connection between the end fitting and adjacent piping. Connectors include bolted flanges, clamped hubs, and proprietary connectors. NOTE They may be designed for diver-assisted makeup or for diverless operation using either mechanical or hydraulic apparatus. 8 API SPECIFICATION 17J 3.1.23 crossover Flexible flowline crossing another pipe already laid on the seabed. 3.1.24 crushing loads Compressive guidance-induced loads or localized compressive loads imposed on the pipe during its installation (laying or retrieval operations) by typical laying equipment such as tensioners, wheel, sheave, chute, gutter, and handling collars or during the operating conditions where the line is bent under tension onto a radius such as J-tube bend, bellmouth, and mid-water arch (MWA) gutter. 3.1.25 design methodology A consistent approach to the design of a component or system. 3.1.26 design tension Maximum combined (static and/or dynamic) tensile load applied to a pipe during installation, operation, or retrieval, after considering the associated internal fluid density and pressure. 3.1.27 dry conditions In air at conditions defined by the international standard atmosphere. 3.1.28 dynamic application Service in which flexible pipe is exposed to cyclically varying loads and deflections during permanent operation. 3.1.29 end of life EOL At the end of the assigned design service life, considering marine growth, expected annulus conditions, material degradation (including but not limited to corrosion, loss of plasticizer, etc.), loss of buoyancy (module loss, compartment loss, water ingress, modules density change, or as otherwise applicable). 3.1.30 end fitting Structural/mechanical device that transfers loads between the flexible pipe and its connector, anchors pipe structural and fluid containment layers, and seals the fluid containment layer(s). 3.1.31 end fitting primary components End fitting primary component are those ensuring the structural integrity under the internal pressure design loads. 3.1.32 environmental assisted cracking Cracking of metallic material subjected to tensile stress (applied and/or residual) under a corrosive environment, e.g. stress corrosion cracking (SCC), sulfide stress cracking (SSC), hydrogen-induced cracking (HIC), or corrosion fatigue (CF). 3.1.33 event, abnormal operation An event due to infrequent loads (e.g. pressures in excess of the design, accidental conditions). SPECIFICATION FOR UNBONDED FLEXIBLE PIPE 9 3.1.34 event, extreme operation An event that produces responses having a low probability of being exceeded in the lifetime of the riser (e.g. an event with a return period of 100 years). 3.1.35 event, extreme temporary An event of short duration due to infrequent loads (e.g. pressures and environments in excess of operating plan, accidental conditions). 3.1.36 event, normal operation An event such as plan of operation; normal; in-place pressure testing; connected operation; and integrity, maintenance, and repair. 3.1.37 event, normal temporary An event of limited duration, such as transport, installation, retrieval, and field test. 3.1.38 event, survival An event involving conditions that exceed extreme design events where fluid containment is just maintained (i.e. material strength utilization is permitted to reach unity). 3.1.39 failure mode effects and criticality analysis FMECA Identifying potential pipe/layer/component failure modes and mechanisms, identifying mitigations, and assessing associated probability and consequence of failure for the entire pipe lifecycle. 3.1.40 fishscaling Tendency of a wire or strip to not lay flat against the underlying layer, often caused by improper preforming during armor winding. Fishscaling can occur in the tensile armor, pressure armor, or carcass layers. 3.1.41 flexible flowline Flexible pipe, wholly or in part, resting on the seafloor or buried below the seafloor and used in a static application. NOTE The term flowline is used in this document as a generic term for flexible flowlines. 3.1.42 flexible pipe Assembly of a pipe body and end fittings where the pipe body is composed of a composite of layered materials that form a pressure-containing conduit and the pipe structure allows large deflections. NOTE 1 Normally, the pipe body is built up as a composite structure composed of metallic and polymer layers. NOTE 2 The term “pipe” is used in this document as a generic term for flexible pipe. 3.1.43 flexible pipe system Fluid conveyance system for which the flexible pipe(s) is the primary component and includes ancillary components attached directly or indirectly to the pipe(s). 10 API SPECIFICATION 17J 3.1.44 flexible riser A flexible pipe in a dynamic or static application, connecting a platform/buoy/ship to a flowline, seafloor installation, or another platform where the riser may be freely suspended (free, catenary), restrained to some extent (buoys, chains), totally restrained, or enclosed in a tube (I- or J-tubes). NOTE The term riser is used in this document as a generic term for flexible risers. 3.1.45 FLIP onset velocity Minimum flow velocity in a flexible pipe at which FLIP occurs. 3.1.46 flow-induced pulsations in corrugated flexibles FLIP Acoustic wave that is caused by the gas flow over the internal corrugations of a rough-bore carcass, as used in dynamic and static risers, flowlines, and jumpers. 3.1.47 fugacity The pressure value at a given temperature needed to make the properties of a nonideal gas satisfy the equation for an ideal gas. NOTE Fugacity corresponds to the effective partial pressure of nonideal gas and is the most relevant parameter for permeation calculation and definition of corrosion-free domain (e.g. SCC). 3.1.48 hydrogen embrittlement Cracking that results from the presence of atomic hydrogen in a metal. 3.1.49 hydrogen-induced cracking HIC Planar cracking that occurs in carbon and low-alloy steels when atomic hydrogen diffuses into the steel and then combines to form molecular hydrogen at trap sites. 3.1.50 hydrogen stress cracking Cracking that results from the presence of atomic hydrogen in a metal and tensile stress (residual and/or applied). 3.1.51 independent design review certificate IDRC (also commonly called IRC) Document established by an IVA within the context of a project certification process, certifying that the flexible pipe design meets API 17J requirements as well as purchaser requirements. SPECIFICATION FOR UNBONDED FLEXIBLE PIPE 11 3.1.52 independent verification agent IVA Independent party or group, selected by the manufacturer, who is responsible for the review and certification of the indicated product concept (e.g. pipe and end fitting concept) and flexible pipe, associated design rules and models (theory manual, validation against tests database), manufacturing methodologies and criteria, QA/QC procedures, material qualification and prototype performance based on the technical literature, analyses, results, and other information provided by the manufacturer to establish the range of applicability. NOTE An agent may also be called upon to witness some measurements and tests related to material qualification, manufacturing process control, validation of design methodologies, and prototype tests. 3.1.53 insulation layer Additional layer added to the flexible pipe to increase the thermal insulation properties, usually located but not limited to between the outer tensile armor layer and the outer sheath. 3.1.54 intermediate sheath Extruded polymer layer located between internal pressure and outer sheaths, which may be used: — as a barrier to external fluids in smooth bore pipes; — as an antiwear layer; — as a barrier from external fluids for insulation layers, avoiding water absorption and creep and thus avoiding reduction in the pipe thermal exchange coefficient (TEC); or — in avoiding flooding of an inner annulus when an outer annulus is flooded. 3.1.55 internal pressure sheath Polymer layer (excluding sacrificial layers) that ensures internal-fluid integrity. NOTE This layer may consist of a number of sublayers. 3.1.56 jumper Short flexible pipe used in subsea and topside, static, or dynamic applications. NOTE Dynamic topside jumpers also includes the class of flexible pipe whose dynamic response derives from vessel motion only (e.g. turret applications). 3.1.57 lateral buckling Buckling of the tensile armors in the lateral direction caused by axial compression (dynamic and/or reverse end-cap loading) and dynamic bending, or static bending and torsion (e.g. during handling and reeling), and affected by the annulus condition (flooded or dry). 3.1.58 lay angle Angle between the axis of a spiral wound element (e.g. armor wires) and a line parallel to the flexible pipe longitudinal axis. 12 API SPECIFICATION 17J 3.1.59 laying tension Maximum tensile load to which the pipe can be subjected during installation or retrieval operations. 3.1.60 liquid volume fraction The total volume fraction of the transferred fluids that are in the liquid phase. This corresponds to the liquid holdup. 3.1.61 load, accidental Loads that are a consequence of unplanned occurrences. 3.1.62 load, environmental Loads that are imposed directly or indirectly by the ocean or atmospheric environment. 3.1.63 load, functional Loads that are a consequence of the system’s existence and use without consideration of environmental or accidental effects. 3.1.64 locking radius The bend radius that cause locking of the interlocked layers. 3.1.65 new pipe design A pipe concept, whose: a) constituting materials, design methodologies, manufacturing processes, and prototype testing results or b) required performance for a specific application have not been accepted by an IVA or the purchaser. 3.1.66 outer sheath Polymer layer used to protect the pipe against penetration of seawater and other external environments, corrosion, abrasion, and mechanical damage. NOTE A protective sheath can be extruded on top of the outer sheath to protect it from mechanical damage or ultraviolet (UV) aging of aerial riser portion. Protective sheaths are not sealed in the end fitting and can be extruded to protect either portions (e.g. riser hangoff and/or touchdown areas) or the entire length of a flexible pipe. 3.1.67 ovalization Out-of-roundness of the pipe, calculated as follows: Dmax − Dmin Dmax + Dmin where Dmax and Dmin are maximum and minimum pipe diameter, respectively. SPECIFICATION FOR UNBONDED FLEXIBLE PIPE 13 3.1.68 overall heat transfer coefficient OHTC A measure of the overall ability of the pipe cross section to transfer heat. NOTE OHTC is the heat transferred per unit area per unit temperature. The area is usually taken as the internal surface area over which the transfer of heat takes place. 3.1.69 permanent operation Operational condition in which pipe is only subjected to operational pressures and temperatures that are less than or equal to the design pressure and design temperature. 3.1.70 piggyback Two pipes attached at regular intervals with clamps, where either or both of the pipes can be flexible. 3.1.71 pipe concept A pipe concept is characterized by the following combination of parameters: a) function (intended use or application); b) structure of layers, sequence and number of layers in the pipe body, type of wire cross section, etc.; c) end fitting’s structural body, details of sealing systems, anchoring system, and vent system. 3.1.72 pressure armor layer Structural layer with a lay angle close to 90° that increases the resistance of the flexible pipe to internal and external pressure and mechanical crushing loads; structurally supports the internal pressure sheath; and typically consists of an interlocked metallic construction, which may be reinforced by an overlying flat metallic spiral layer. 3.1.73 prototype test Test to evaluate a principal performance characteristic for a particular pipe design, which may be a new or established design. It can be used to qualify a pipe design, verify a predicted performance, or validate design analysis methodology. 3.1.74 qualification testing Testing by which the structural, functional, fabrication, and reliability performance of a pipe concept, its components, or materials used may be evaluated in order to demonstrate suitability for the specified service life in a specific application. NOTE The qualification test can also be used to validate the manufacturer’s design methodology for a new pipe design. 3.1.75 reflection coefficients The (absolute) fraction of the amplitude of an acoustic wave that is reflected by the pipe system to the flexible pipe. It is an acoustic property of the pipe system attached to a flexible pipe, used in FLIP evaluations. 3.1.76 rough bore Flexible pipe with a carcass as the innermost layer. 14 API SPECIFICATION 17J 3.1.77 sacrificial layer Polymer layer located beneath or above the internal pressure sheath layer, or above the outer sheath layer, and not bonded to any of the layers. 3.1.78 service life Period of time during which the flexible pipe is designed to fulfil all specified performance requirements. 3.1.79 smooth bore Flexible pipe with an internal pressure sheath as the innermost layer. 3.1.80 sour service Service conditions with a H2S content exceeding the minimum specified by ANSI/NACE MR0175/ISO 15156. NOTE 1 Sour service condition in the bore does not always lead to sour service conditions in the pipe annulus. NOTE 2 Design pressure is used to assess bore conditions; operating pressure is used to assess annulus condition. 3.1.81 start of life SOL After offshore leak test (OLT)/commissioning and prior to establishment of any marine growth. 3.1.82 static application Flexible pipes not exposed to cyclically varying loads or deflections during permanent operations. 3.1.83 stress corrosion cracking SCC Environmental assisted cracking phenomenon of a susceptible metal occurring under static mechanical load (residual stresses from manufacturing process and applied stresses from mechanical loading) in presence of aqueous corrosive environment (e.g. CO2). 3.1.84 sulfide stress cracking SSC Cracking of metal involving corrosion and tensile stress (residual and/or applied) in the presence of water and hydrogen sulfide. 3.1.85 survival Survival of a component means that the component does not fail, but it can present one or more kinds of degradation that could jeopardize its specified performance or service life. 3.1.86 sweet service Service conditions that have a H2S content less than the minimum specified by ANSI/NACE MR0175/ISO 15156. SPECIFICATION FOR UNBONDED FLEXIBLE PIPE 15 3.1.87 tensile armor layer Structural layer with a lay angle typically between 20° and 55°, which consists of helically wound metallic wires and is used to sustain, totally or partially, tensile loads and internal pressure. NOTE Tensile armor layers are typically counter-wound in pairs. 3.1.88 tensioner Mechanical device used to apply tension or support a pipe by applying radial loads to the pipe with moving tracks during its installation or retrieval. 3.1.89 thermal exchange coefficient TEC Coefficient that provides the heat loss (expressed in Watts) of 1 m of pipe when subjected to 1 °C difference between its internal and external surfaces. NOTE The TEC is typically determined for conditions corresponding to the design water depth and steady-state annulus environment (intact and seawater flooded) and accounting for water absorption in the insulation layers. 3.1.90 torsional balance Pipe characteristic that is achieved by designing the structural layers in the pipe, such that axial and pressure loads do not induce significant twist or torsional loads in the pipe. 3.1.91 torsional limp stiffness The ability of a flexible pipe to resist twist, at constant tension, when subjected to torsion loads applied in the opposite direction to the lay angle of the outermost tensile armors. 3.1.92 true wall force The axial force acting in the pipe wall. 3.1.93 type approval certificate TAC Certificate and its appendices issued by an IVA for the indicated product and a specific manufacturer, confirming the suitability and ranges on the manufacturer’s design methodologies and criteria, manufacturing processes, and materials in compliance with the requirements of its applicable standard. 3.1.94 unbonded flexible pipe A pipe construction that consists of separate unbonded polymeric and helical reinforcement layers, which allows relative movement between layers. 3.1.95 validation test A test to validate predicted pipe performance and/or design tool. 3.2 Acronyms, Abbreviations, and Symbols CF corrosion fatigue CIV corrected inherent viscosity 16 API SPECIFICATION 17J COC certificate of conformity DSC differential scanning calorimeter EOL end of life FAT factory acceptance test FLIP flow-induced pulsation FMECA failure mode, effects, and criticality analysis GRV gas release valve HAZ heat-affected zone HIC hydrogen-induced cracking HSE health, safety, and environment HV hardness on Vickers scale ID internal diameter IDRC independent design review certificate IPU integrated pipe umbilical IVA independent verification agent LR locking radius LVF liquid volume fraction MBR minimum bend radius MDS material data sheet MFI melt flow index MPI magnetic particle inspection MQP manufacturing quality plan MVR melt volume rate MWA mid-water arch NDE nondestructive examination OBR operating bend radius OD outer diameter OHTC overall heat transfer coefficient OLT offshore leak test PA polyamide SPECIFICATION FOR UNBONDED FLEXIBLE PIPE 17 PAUT phased array ultrasonic testing PE polyethylene PLEM pipeline ending manifold PLET pipeline end termination PSL product specification level PVC polyvinyl chloride PVDF polyvinylidene fluoride ROV remotely operated vehicle SIT structural integrity test S-N curves showing stress range vs number of cycles SOL start of life SR storage minimum bend radius SCC stress corrosion cracking SSC sulfide stress cracking TAC type approval certificate TAN titrated acid number TEC thermal exchange coefficient TFL through flowline TPE thermo-plastic elastomer UV ultraviolet WPS welding procedure specification XLPE cross-linked polyethylene F design pulling force Fy anchoring system capacity Kt stress or strain concentration factor derived from the ratio of the highest stress or strain at polymer sheath surface undulation to the reference far-field stress or strain at the polymer sheath without such undulation n permissible stress utilization factor t thickness of component σe equivalent stress (von Mises or Tresca) σt tensile hoop stress σy material yield stress 18 API SPECIFICATION 17J 4 Functional Requirements 4.1 General The functional requirements for the flexible pipe shall be specified. The purchasing guidelines in Annex A give a sample format for the specification of the functional requirements. NOTE All functional and design requirements are typically specified by the purchaser. Functional requirements not specifically required or not specified by the purchaser and that can affect the design, materials, manufacturing, and testing of the pipe shall be specified by the manufacturer and submitted to the purchaser. If the purchaser does not specify a requirement, and the above does not apply, the manufacturer may assume that there is no requirement. 4.2 4.2.1 Overall Requirements Flexible Pipe The minimum overall functional requirements of the flexible pipe that shall be demonstrated by the manufacturer are as follows: a) the pipe shall provide a leak-tight conduit, b) the pipe shall be capable of withstanding all design loads and load combinations defined in Section 5, c) the pipe and each of its layers shall perform its function for the specified service life, d) the flexible pipe materials shall be compatible with the environment to which the materials are exposed. 4.2.2 End Fitting The manufacturer shall demonstrate that the end fittings, which are an integral part of the flexible pipe, also meet the following: a) the end fitting shall provide a structural interface between the flexible pipe and the support structure; b) when applicable, the end fitting shall provide a structural interface between the flexible pipe and bend-limiting devices, including bend stiffeners, bend restrictors, and bellmouths, such that the bend-limiting devices meet their functional requirements. 4.3 General Design Parameters Project-specific design requirements shall be specified, including the requirements of 4.4 to 4.6 and the following: a) nominal internal diameter (ID); b) length and length tolerances of flexible pipe, including end fittings—whether length tolerance is defined symmetrically around nominal or skewed to either side should depend on the criticality for the system; c) service life; SPECIFICATION FOR UNBONDED FLEXIBLE PIPE 19 d) time onshore for storage, time after delivery and before first installation, time for wet parking on the seabed, and the conditions associated to each of these life phases; e) classes of annulus (as per Table 9) for riser (and riser sections if applicable) and for flowlines, providing also (as applicable) details on required vent connections for annulus inspection and monitoring during operation. 4.4 Internal Fluid Parameters 4.4.1 General The internal fluid parameters for the application shall be specified. The parameters listed in Table 1 shall be specified. Expected variations in the internal fluid parameters over the service life shall be specified. NOTE Internal fluid parameters are typically specified by the purchaser. Slug flow data to be specified shall include slug density, length, frequency, and distribution over the service life for production flexibles. Table 1—Internal Fluid Parameters Parameter 4.4.2 Comment Internal pressure See 4.4.2 Temperature See 4.4.3 Fluid composition See 4.4.4 Fluid/flow description Fluid type and flow regime Flow rate parameters Flow rates, fluid density, viscosity, minimum inlet pressure, and required outlet pressure Thermal parameters Fluid heat capacity Internal Pressure Definitions The internal pressures that are relevant to the design, testing, and operation of an unbonded flexible pipe are defined in Figure 1 and Table 2. FAT values higher than those mentioned in Table 2 may be used by the manufacturer to release residual stresses. Structural integrity tests (SITs) higher than those mentioned in Table 2 may also be proposed by the manufacturer to release residual stresses and will depend on system and vessel limitations. The following internal pressures shall be specified by the purchaser: a) design pressure, b) maximum operating pressure, c) incidental pressure. The following internal pressures data should be specified by the purchaser: a) operating pressure profiles (histogram with yearly resolution) along the pipe and through the service life; b) the lowest maximum internal pressure of the system within which the flexible pipe is to be OLT or SIT tested, see Table 2 OLT and offshore SIT; 20 API SPECIFICATION 17J c) FAT, OLT, and offshore SIT pressure requirements of the purchaser and/or governing certifying authorities; d) maximum pressurization rate; e) maximum depressurization rate or profile change with time; f) number of extreme pressure cycles (e.g. from the maximum to the minimum operating—or design—pressure and return to the specified operating pressure associated or not to the thermal cycles); g) minimum pressure (vacuum pressure if relevant). Burst Pressure Test Pressure Incidental Pressure Maximum Operating Pressure Operating Pressure Minimum Pressure Figure 1—Internal Pressure Definitions Increasing Pressure Design Pressure SPECIFICATION FOR UNBONDED FLEXIBLE PIPE 21 Table 2—Internal Pressure Definitions Pressure (1) Definition Minimum pressure The minimum internal pressure experienced by the pipe during its life (installation and operating conditions). A conservative estimate is to assume a vacuum. Design external pressure Maximum external pressure (e.g. external hydrostatic or annulus) applied to a pipe during installation, operation, or retrieval, after considering tidal and wave effects, which is the maximum pressure acting external to a sheath layer. Differential pressure The difference between the internal pressure and the external pressure (e.g. external hydrostatic or annulus) at a reference location acting either on the sheath, sealing, component or pipe. Operating pressure The internal pressure profile experienced by the pipe during permanent normal operation over its service life. Maximum operating pressure The maximum internal pressure, at a reference location (2), to which the pipe is subjected during permanent normal operation. Design pressure The maximum internal pressure, at a reference location, including planned shut-in pressure and associated surge. Incidental pressure The maximum internal pressure, at a reference location, that is unlikely to be exceeded during the life of the pipe, due to abnormal operation, unintended shut-in pressure, surge pressure, or other temporary incidental condition. Unless otherwise specified by the purchaser, the maximum incidental pressure is 1.1 times the design pressure. Test Pressure Factory acceptance test (FAT) (5) Offshore leak test (OLT) (5) SIT (onboard integrity test) (3) (5) The internal pressure applied to the pipe or pipe section during testing after manufacture to test for latent defects. Unless otherwise specified by the purchaser, the FAT pressure is 1.5 times the maximum differential pressure (difference between the design pressure and the external hydrostatic) for flexible risers and topside jumpers and 1.3 times the maximum differential pressure for flexible flowlines and subsea jumpers. The internal pressure applied to the pipe or pipe section during testing after installation to test for leak tightness. Unless otherwise specified by the purchaser, the OLT pressure is 1.1 times either (a) the design pressure of the pipe or (b) the lowest maximum internal pressure of the system, whichever is lower. The internal pressure applied to the pipe or pipe section during testing on board the installation vessel to test the structural integrity of the pipe. Unless otherwise specified by the purchaser, the structural integrity test (SIT) pressure shall be as per the FAT pressure. SIT (offshore integrity test) (4) (5) (6) The internal pressure applied to the pipe or pipe section during testing in situ after installation to test the structural integrity of the pipe. Unless otherwise specified by the purchaser, the SIT pressure shall be 1.25 times either (a) the design pressure of the pipe or (b) the lowest maximum internal pressure of the system, whichever is lower. Burst pressure The pressure at which loss of fluid containment in the pipe occurs due to pipe or end fitting failure. NOTE 1 The pressure can be a function of location along the pipe and/or time. NOTE 2 Unless otherwise specified, for injection or export risers, the reference location should be at the topside; for production risers, the reference location should be at the wellhead or other equipment where the flexible pipe is connected to a manifold, pipeline end termination (PLET), pipeline ending manifold (PLEM), etc. NOTE 3 The onboard structural integrity pressure test is required if the pipe is fully retrieved and repaired on board the installation vessel and when the structural integrity of the reinforcement layers or end termination pressure-containment parts have been affected. NOTE 4 The offshore structural integrity pressure test is required post installation if the pipe is repaired in situ and when the structural integrity of the reinforcement layers or end termination pressure-containment parts have been affected, or to reassess the integrity vs suspected damage/reduced resistance. See API 17B, Section 9.5.3.1 b). NOTE 5 Temporary tests like FAT, SIT, and OLT should not drive the design of the flexible pipe. In these cases, lower factors than the default values listed can be proposed by manufacturer and approved by purchaser. NOTE 6 For SIT of flexibles operated subsea, the impact of annulus pressure on armor wire stresses should be accounted for. 22 API SPECIFICATION 17J 4.4.3 Temperature Definitions The internal temperatures that are relevant to the design, testing, and operation of an unbonded flexible pipe are defined in Table 3. The temperatures shown in Table 3 and the duration of the incidental temperature shall be specified by the purchaser. Operating and design temperatures should be specified on the basis of the following minimum set of permanent operating considerations: a) upset temperatures (number and range of cycles); b) gas-cooling effects (time/temperature curve); c) fluid thermal characteristics; d) flow characteristics; e) storage, transport, and installation conditions; f) number of extreme temperature cycles (e.g. from the maximum to the minimum operating—or design —temperature and return to the specified operating temperature associated or not to the pressure cycles); g) operating temperature profiles (histogram with yearly resolution) along the pipe and through the service life. Table 3—Temperature Definitions Temperature Definition (1) Operating temperature The internal temperature profile experienced by the pipe over its service life during permanent normal operation Maximum/minimum operating temperature The maximum and minimum internal temperature to which the pipe is subjected during permanent (3) normal operation Design temperature The maximum and minimum internal temperature to which the pipe is subjected during permanent (3) operation Incidental (2) temperature The maximum and minimum internal temperature that is unlikely to be exceeded during the life of the pipe NOTE 1 At the inner surface of the pipe. NOTE 2 Incidental temperatures should be specified on the basis of abnormal operating considerations, including unplanned transient events. NOTE 3 “Permanent” operating conditions are defined in Table 6. 4.4.4 Fluid Composition The produced fluid composition, injection fluids, and continual and occasional chemical treatment (dosages, exposure times, concentrations, and frequency) shall be specified. In the specification of the internal fluid composition, the following shall be defined: a) all parameters that define service conditions (for a reference condition), including partial pressure (or concentration or fugacities; include information about location, temperature, and pressure for specified data) of H2S and CO2, organic acids (formic, acetic, propanoic), pH of aqueous phase in situ, titrated acid number (TAN) (in accordance with ASTM D664 or ASTM D974), and water content and ionic composition (produced water, seawater, and free water); NOTE 1 In case H2S is not part of purchaser-provided fluid composition, manufacturer to check with the purchaser at which year of operation souring may occur and at what H2S level. SPECIFICATION FOR UNBONDED FLEXIBLE PIPE 23 b) gases, including oxygen, hydrogen, methane, and nitrogen; c) liquids, including oil composition, alcohols, and produced water ionic composition; d) aromatic components; e) corrosive agents, including bacteria, chlorides, organic acids, and sulfur-bearing compounds; f) chemical products, including alcohols and inhibitors for corrosion, paraffin, scale, and wax (including concentrations of dissolved oxygen); the chemical product reference, injected quantity, and utilization frequency shall be specified; NOTE 2 Guidance of use can be captured in the operating and inspection manual (see 8.9). g) solids, including sand, precipitates, scale, hydrates, wax, and biofilm; h) drilling, completion, or workover fluids (including concentrations of dissolved oxygen); i) fluid densities shall be specified for all design life stages (see Table A.1). NOTE 3 4.5 Fluid composition is typically specified by the purchaser. External Environment The project external environmental parameters inclusive of those listed in Table 4 shall be specified. The design water depth shall be the maximum water depth to which the pipe section may be exposed. Table 4—External Environment Parameters Parameter Comment Location Geographical data for the installation location Water depth Design water depth, variations over pipe location, and tidal variations Seawater data Density, salinity, pH value, and minimum and maximum temperatures, O2 dissolved in water Air temperature Minimum and maximum during storage, installation, and operation Soil data Description, shear strength or angle of internal friction, friction coefficients seabed scour, soil type description (from soft to hard, sand/clay), thermal conductivity, roughness, grain size, soil stability, liquefaction and submerged/dry unit soil weight, sand waves, and variations along pipe route Backfill or cover soil Description of backfill and cover material type, density, and significant properties for use in upheaval buckling or related calculations and analysis Marine growth Density and thickness variations with water depth Ice Maximum ice accumulation or drifting icebergs and ice floes Sunlight exposure Length of pipe exposed during operation and storage conditions and time of exposure Current data As a function of water depth, direction, and return period, and including the known effects of local current phenomena Wave data In terms of significant and maximum waves, associated periods, wave spectra, spreading functions, and scatter diagrams, as a function of direction and return period Wind data As a function of direction, height above water level, and return period NOTE Project external environment parameters are typically specified by the purchaser. 24 API SPECIFICATION 17J 4.6 System Requirements 4.6.1 Minimum System Requirements 4.6.1.1 General The system functional requirements of the project shall be specified. Annex A may be referenced for guidelines. Unless otherwise stated in 4.6.1, the minimum system requirements in 4.6.1.2 to 4.6.1.12 shall be specified. NOTE 4.6.1.2 Minimum system requirements are typically specified by the purchaser. Application Definition The flexible pipe system shall be specified including flowline, riser or jumper, and ancillaries. The flexible pipe application shall be specified as either static or dynamic, and the expected number of load cycles and magnitudes should be specified for dynamic cases. The flexible pipe global configuration shall be specified. 4.6.1.3 Corrosion Protection The corrosion protection requirements for the flexible pipe service shall be specified, considering the following: a) end fitting internal and external corrosion protection; b) cathodic protection system for the pipe; c) protection voltage, current source, and current density; d) protection for storage (onshore or subsea storage) and installation as applicable; e) compatibility with corrosion protection systems adjacent to the corrosion protection system of the flexible pipe; f) buried or unburied. 4.6.1.4 Thermal Insulation Performance requirements in permanent or transient operations of the flexible pipe for heat loss or retention shall be specified. OHTCs shall be based on pipe nominal ID and shall differentiate between the pipe itself and any external effects, such as soil cover for buried pipe. 4.6.1.5 Gas Venting The purpose of a gas-venting system is to prevent excessive pressure buildup in the annulus of the pipe. If gas venting is required, the following shall be specified: a) gas-venting system components; b) flow capacity of the system; c) interface requirements; d) gas-monitoring system; SPECIFICATION FOR UNBONDED FLEXIBLE PIPE 25 e) underwater vent valves, as applicable; f) back pressure of the vent system to which the pipe is connected; g) integrity inspection of annulus; h) purchaser to specify requirements for interconnecting of annulus for multi-section pipes; i) purchaser to specify retrieval rate, this is to be confirmed by manufacturer. 4.6.1.6 Pigging and Through Flowline (TFL) Requirements Any performance requirements for allowing tools for pigging, TFL, workover, or other operations through the flexible pipe, including ID, bend radius, and end fitting transitions, shall be specified. Pigging requirements for the flexible pipe shall be specified in terms of expected pigging program in service, during commissioning and decommissioning. 4.6.1.7 Fire Resistance Whether fire resistance is required shall be specified. If required, the following information should be specified: a) fire temperature, source, and surrounding material; b) need to extinguish or cool the pipe structure; c) fire-extinction method; d) duration required for pipe survivability; e) transported medium; f) heated steel in contact with polymeric material in the flexible pipe; g) pipe-abandonment facility and its fire protection capability; h) pipe function; i) flashpoint of transported medium in the event of a leak; j) depressurization time. NOTE 4.6.1.8 Fire resistance requirement is typically determined by the purchaser. Piggyback Lines Any piggyback requirements for the flexible pipe shall be specified, including details of the piggyback pipe(s) and pipe-operating conditions. 4.6.1.9 Connectors The connector requirements for both end fittings in the flexible pipe shall be specified, including, as a minimum, connector type, welding specification, seal type, and sizes. 26 API SPECIFICATION 17J 4.6.1.10 Interface Definitions Interface details including, but not limited to, the following shall be specified by the purchaser: a) regulations, codes, and standards, including definition of code breaks; b) geometric, dimensional, and imposed loading data; c) purchaser-supplied installation aids and equipment; d) purchaser-supplied pull-in and connection tools and terminations; e) vessel/platform interface structures such as I-tubes and bellmouths; 1) definition of platform coordinate system; 2) position and description of interfacing face; 3) definition of allowable interface loads transmitted from flexible pipe to the interface structures; f) interfacing subsea equipment such as tree and manifolds; 1) position and description of interfacing face; 2) elevation and angle of interfacing face; 3) allowable interface loads; 4) design displacement values (i.e. thermal expansion); 5) design tolerances of position of interfacing face (i.e. installation tolerance); 6) capacity of tie-in tool (at each step of tie-in); 7) structural drawing of interfacing structures; g) manufacturer scope of supply. 4.6.1.11 Inspection and Condition Monitoring The requirements for the manufacturer to design and implement flexible pipe inspection, monitoring, and condition assessment systems and procedures shall be specified by the purchaser. Coupons should be considered for any pressure sheath; see API 17B, Section 11 for more details. 4.6.1.12 Shipping, Storage, and Handling Any requirements for shipping, storage, and handling with respect to all conditions, facilities, equipment, and procedures involved shall be specified. Any requirements for wet storage shall be specified. SPECIFICATION FOR UNBONDED FLEXIBLE PIPE 27 4.6.1.13 Installation and Retrieval Requirements Performance requirements for installation and retrieval services to be provided shall be specified, considering the following as a minimum. a) For installation/retrieval by the purchaser, requirements on load restrictions, clamping/tensioner loads and dimensions, vessel motions, overboarding chute or wheel requirements, installation tolerances, and port facility limitations, as well as transpooling between different vessels, shall be specified. b) For installation/retrieval by the manufacturer, requirements for season, environment, vessel limitations, installation tolerances, restrictions due to conflicting activities and installation scope (including trenching, burial, testing, inspection, surveying, and documentation), installation and retrieval with empty or flooded pipe, and number of foreseen installation and retrieval operations shall be specified. c) Installer shall advise maximum acceleration and deceleration during installation/recovery in order to allow full assessment of the impact of additional inertial forces in the tensioner calculations. Reference is made to DNV-ST-N001. Requirements for recoverability and reusability of the flexible pipe within its service life shall be specified. NOTE Requirements for installation and retrieval are typically specified by the purchaser. 4.6.1.14 Exothermal Chemical Reaction Cleaning Relevant parameters for the pipe-cleaning operations by means of exothermal chemical reaction shall be specified, considering the following as a minimum: a) flow rate, b) pressure variation, c) maximum heat output, d) chemical composition, e) maximum temperature reached by the chemical reaction, f) temperature profile along pipe, g) duration of the cleaning operation, h) number of cleaning operations to be performed during pipe service life. 4.6.1.15 Pre-comissioning and Comissioning Activities Pre-commissioning and commissioning activities, which shall be considered in design, shall be specified. Such activities shall include planned exposure to temporary fluids with corresponding sea state and duration. 4.6.2 Flowline and Riser Parameters Requirements for design and analysis of the flowline and riser (or jumpers) system additional to the requirements of Section 5 shall be specified by the purchaser to the manufacturer considering the parameters listed in Table 5 as a minimum. 28 5 API SPECIFICATION 17J Design Requirements 5.1 Loads and Load Effects 5.1.1 General The pipe design is based on the information supplied by the purchaser (see guidelines in Annex A), with reference to the requirements of Section 4. 5.1.2 Definition of Load Classes Loads are classified as functional (permanent and variable), environmental (external), or accidental. Typical load combinations and load classes are listed in Table 6 and Table 7, respectively. The design load cases shall be defined to analyze, as applicable, the effect on the flexible pipe of functional, environment, and accidental loads. See API 17B for guidelines on the analysis techniques to be used for the loads given in Table 7. 5.1.3 Load Combinations and Conditions The flexible pipe design shall be shown to meet the design requirements under the load combinations specified in 5.1.3. All loads that act on the flexible pipe shall be evaluated for the load conditions specified in Table 6. The flexible pipe design shall consider start of life (SOL) and end of life (EOL) conditions. Variation of the loads in time (from SOL until EOL) and space, and load effects from the flexible pipe system and its supports, as well as environmental and soil conditions, shall be analyzed. The design load conditions that shall be analyzed are permanent operation (normal and extreme), abnormal, temporary, and survival events. Load combinations shall be as defined in Table 6. Load combinations with a yearly probability of occurrence less than 10−4 can be ignored. FAT load combinations shall be defined by the manufacturer based on the FAT procedures. Different load combinations shall be considered for installation, extreme, interference, and fatigue analyses. Load case matrices for extreme, interference, and fatigue analyses shall be listed in the design premise and output covered in the design load reports. The matrices shall cover relevant load cases as discussed in relevant sections of this document. Design checks shall be carried out for any temporary conditions, which may include testing (FAT, OLT, SIT), installation, abandonment, retrieval, handling, and storage, specified by the purchaser or the manufacturer, subject to the design criteria as specified in Table 8. The simultaneous occurrence of different load combinations shall be defined. The probability of specific load combinations may be specified by the purchaser based on project-specific conditions. The probabilities of accidental and installation-related events should be specified by the purchaser. If the purchaser does not specify probabilities, the manufacturer shall propose the probabilities that are used for the individual events. These specified probabilities shall be consistent with the probabilities shown in Table 6 and mentioned above. The design load cases analyzed shall be derived from the load combinations in Table 6. 5.1.4 Design Load Effects Design loads give rise to tension/compression, bending, and torsion, which shall be considered in pipe design. In the pipe design, the manufacturer shall account for the effects of internal and external pressures and temperatures. SPECIFICATION FOR UNBONDED FLEXIBLE PIPE 29 The pipe design shall account for any ancillary components attached to the pipe, including bend stiffeners. The bend stiffener shall be included in the global riser analysis model to verify riser strength and fatigue performance. Hydrodynamic load effects shall be determined by validated and documented methods that account for the kinematics of the seawater and the interaction effects of the different environmental phenomena. See API 17B for guidelines on analysis methods. All effects that are relevant and captured by manufacturers and that enable a more accurate prediction of each failure mode shall be considered when building a model that could be either validated or calibrated. When designing flexible pipe cross section, manufacturers shall ensure that these effects are considered on a conservative basis. Table 8 presents strain limits for polymeric materials; however, for each polymer material for both static and dynamic applications, the allowable bending strain shall be as specified by the manufacturer, who shall document that the material meets the design requirements at that strain. For fatigue analysis, the distribution of loads over the service life of the pipe shall be based on methods that include all load parameters. Simplified methods are acceptable if the resulting load distribution can be shown to be conservative. Any accidental loads or combinations thereof can damage or render unfit for service a flexible pipe. Load cases that include accidental loads (e.g. increased offsets due to anchor line or thruster failures) and do not violate the requirements of Table 8 define a limit on the safe occurrence of the accidental loads. Some accidental loads (e.g. fire and explosion) might not be easily analyzed in terms of the requirements in Table 8. In such cases, testing shall be used to define safe working times of other limits associated with the accidental load. Design load cases shall consider intact annulus filled with condensed water, and annulus flooded with deaerated seawater conditions, and associated gas species for each condition. The conditions of the annulus containing armor wires shall be defined in accordance with Table 9 classification in line with project service requirements and agreed with purchaser. Pipe and end fitting design and factory sealing test requirements shall be implemented per Table 9 in line with the agreed classification. For example, applications of Table 9 are provided in Table 13 in API 17B. Wet storage load cases should be considered. In addition, the annulus flooded with aerated seawater shall be regarded as an accidental case. Additional mechanical protection may be considered to mitigate risk of annulus exposure to aerated seawater. Intentional flooding of the annulus with either aerated or deaerated seawater is allowable provided manufacturer has appropriate design data to verify the intended service life per Class 0, Table 9. 30 API SPECIFICATION 17J Table 5—Flowline and Riser Parameters Parameter Flowline routing Riser configuration Load cases Guides and supports Pipe attachments Connection systems Protection requirements Details — Route drawings, topography, seabed/soil conditions, obstacles, and installed equipment and pipelines. — Specification of any requirements for the configuration, including description (lazy-S, steep wave, etc.), layout, and components. Selection of configuration or confirmation of suitability of specified configuration. — Flowline Riser X X — Functional, environmental, and accidental load cases and combined yearly probability for permanent operation (normal and extreme), abnormal, temporary (e.g. installation), and survival events. X X — Proposed geometry of guides, I-tubes, J-tubes, hangoff, and bellmouths through which flowline and riser is to be installed and mid-water arches. X X — Bend restrictors, bend stiffeners, clamps, buoyancy modules, and attachment methods. X X — Descriptions of upper and lower connection systems, including quick disconnection systems and buoy disconnection systems, connection angles, and location tolerances. X X — Trenching, rock dumping, mattresses, external coatings, and extent of protection requirements over length of pipe. Design impact loads, including those from trawl boards, dropped objects, and anchors/anchor chains. X X — On-bottom stability — Allowable displacements. X Upheaval buckling — Specification of design cases to be considered by manufacturer. X — Crossing of pipes (flexible and rigid), including already installed pipes and gas lines. X — Specification of possible interference areas (e.g. hull, mooring lines, anodes, safety nets, lifeboat drop zone and loading zones). Definition of allowable interference/clashing. If a dynamic riser is to be installed in an existing riser system, configuration data and weight/diameter ratio for neighboring risers, cables, and dynamic umbilicals shall be specified. Crossover requirements Interference requirements Interface loads and displacements Attached vessel data X — — — Include interfacing hub loads or displacement envelope from adjacent structures (e.g. pipeline expansion). — Data for attached floating vessels, including but not limited to the following: a) vessel data, dimensions, drafts, heading, and the like; b) static offsets; c) first- (response amplitude operators for extreme and fatigue analyses) and second-order motions; d) vessel motion phase data; e) vessel motion reference point; f) mooring system interface data; g) position tolerances. X X X X X SPECIFICATION FOR UNBONDED FLEXIBLE PIPE 31 Table 6—Load Combinations of Load Classes, Load Conditions Load Conditions Load Classes (1) (9) (10) Operating Conditions Permanent Normal Permanent functional Variable functional Environmental Accidental Combined probability, Pc (3) Extreme Nonoperating Conditions Abnormal Temporary Normal Survival Extreme (2) Permanent functional load associated with the corresponding load condition. Max. operating pressure Design pressure (9) ≤ Max incidental pressure Purchaser-specified pressure Max./min. operating temp. Design temp. ≤ Incidental temp. Purchaser-specified temperature Operating plan ≥10–2 ≤10–2 Seasonal (8) Specified by purchaser ≥10–4 n/a (4) X (6) (7) X (6) n/a X X Assoc. (5) 10–2 ≤10–2 Assoc. ≥10–2 ≥10–4 NOTE 1 See Table 7 for details. NOTE 2 The environment cannot be controlled or the variable functional loads exceed the maximum incidental values. NOTE 3 Combined probability of occurrence, Pc, refers to the combination of independent environmental conditions and accidental events only, excluding functional loads. The occurrence probabilities refer to yearly probability of occurrence. NOTE 4 n/a—not applicable. NOTE 5 “Assoc.” implies the functional loads associated with the load condition under consideration. NOTE 6 For extreme or abnormal operating condition, the event itself may represent the condition following an accidental event (e.g. with a mooring line failure). NOTE 7 “X”—to be considered; see Table 7 for details of typical accidental loads. NOTE 8 Purchaser-specified return period. If not specified assume a 3-month return period. NOTE 9 Use minimum pressure instead of design pressure where relevant. NOTE 10 Use associated density values for each load combination. 32 API SPECIFICATION 17J Table 7—Typical Load Classes Functional Loads 1) Loads due to weight and buoyancy of pipe, contents, and attachments, both temporary and permanent. 2) External pressure. 3) External soil or rock reaction forces for trenched, buried, or rock-dumped pipes. 4) Static reaction and deformation loads from supports and protection structures. 5) Temporary installation or recovery loads, including applied tension and crushing loads, impact loads, and guidance-induced loads. 6) Residual installation loads, which remain as permanent loads in the pipe structure during service. 7) Loads and displacement due to pressure and tension-induced rotation. 8) Testing pressures, including installation, commissioning, and maintenance pressures. 9) Interaction effects of bundled or clamped pipes. 10) Loads due to rigid or flexible pipe crossings, or spans. 11) Loads due to positioning tolerances during installation. 12) Loads from inspection and maintenance tools. 13) Loads from multiphase flow slugging, where applicable. 14) Loads from restraint due to packaging (e.g. factory acceptance test testing). 15) Internal pressure as specified in 4.4.2. 16) Loads from pressure and temperature variations. Environmental Loads 1) Loads caused directly or indirectly by all environmental parameters specified in Table 4. 2) Second-order slow drift motions and/or vortex induced motions of the floating facility or subsurface equipment to which the flexible riser is attached, where applicable. Accidental Loads Loads and motions caused directly or indirectly by accidental occurrences involving external loads acting on the pipe, including the following. 1) Dropped objects. 2) Trawl board impact. 3) Internal overpressure. 4) Compartment damage or unintended flooding of vessel compartment. 5) Failure of thrusters. 6) Dynamic positioning system failure. 7) Anchor line failure. 8) Failure of turret drive system. 9) Failure of relevant ancillary equipment that is likely to impact on the configuration of the pipe (e.g. buoyancy or ballast module), flooding of buoy compartment/tank at a critical location, or failures of tethers/bridles (in line with API 17L1 and API 17L2). 10) Internal pressure difference across a blockage, e.g. a hydrate plug, where applicable. 11) Interference between flexible pipe and other structures. Table 8—Flexible Pipe Layer Design Criteria Operating Conditions Layer Primary Pipe Failure Mode Design Criteria Nonoperating Conditions Permanent Normal Temporary Extreme Abnormal Normal Installation Test Survival Extreme Internal carcass Collapse (1) (2) Load Inner liner smooth bore Collapse (1) Load For each polymer material for both static and dynamic applications, the allowable utilization for collapse shall be as specified by the manufacturer, who shall document that the material meets the design requirements at that load. Thinning (3) The maximum allowable reduction in wall thickness over the service life below the minimum design value, due to deformation into gaps in the supporting structural layer, shall be 30 % under all load combinations. Strain The maximum allowable bending strain at nominal dimensions shall be 7.7 % for polyethylene (PE) and polyamide (PA), 7.0 % for polyvinylidene fluoride (PVDF) in static applications and for storage in dynamic applications, and 3.5 % for PVDF for operation in dynamic applications (4). Internal pressure Rupture sheath Loss of interlock, Stress Pressure armors breakage 0.85 0.67 0.85 0.85 0.97 (5) 0.67 0.91 (9) 0.85 Collapse (1) (2) Load Breakage Stress (11) Buckling Load Wire disorganization Displacement The cumulative radial gap between each tensile armor and its adjacent layers shall not exceed half the wire thickness. Anti-collapse sheath (6) Rupture Strain The allowable utilization for anti-collapse sheath shall be as specified by the manufacturer. Anti-buckling tape Birdcaging (7) Stress or strain (8) Outer sheath Rupture Strain Tensile armors 0.85 0.97 (5) 0.67 0.85 0.85 0.97 (5) 0.67 (10) 0.91 (9) 0.85 0.97 (5) 0.85 0.67 0.67 0.85 0.85 0.85 0.85 The maximum allowable bending strain at nominal dimensions shall be 7.7 % for PE and PA. 0.91 NOTE 1 The collapse resistance shall account for all sources of ovalization, i.e. from manufacture, test, installation, and operation (see 5.3.2.4). Maximum permissible ovalization criteria (under load and in unloaded condition) are to be defined by the manufacturer. Guidance can be found in API 17B. NOTE 2 other. For rough bore pipe, the stress can reach the material yield strength in one of the carcass or pressure armor layers, provided that the allowable utilization is not exceeded in the NOTE 3 Thinning includes elastic, plastic, and creep-induced reduction in thickness (see 5.3.2.1). NOTE 4 For quasi-dynamic and dynamic-supported applications, higher maximum bending strain may be allowed for PVDF, if validated by testing. See footnotes to Table 10 for definition of quasi-dynamic and dynamic supported. NOTE 5 A margin of 3 % accounts for the allowable variation in utilization due to manufacturing tolerances (see 5.2). NOTE 6 For smooth bore pipes used for gas or gas/liquid applications, design, manufacturing, and factory acceptance test (FAT) requirements for the anti-collapse sheath shall be agreed between the purchaser and manufacturer. NOTE 7 Birdcaging of the tensile armor wires. NOTE 8 For non-steel materials used for anti-buckling tapes, utilization factors are applied on strength or strain capacity and shall capture both the beginning and the end of life conditions. NOTE 9 For stress analysis, the maximum internal pressure experienced during FAT, offshore leak test, and structural integrity test shall be considered. NOTE 10 Higher utilization factor up to 0.85 may be considered if approved by the purchaser or independent verification agent. NOTE 11 Applicable to tensile stresses. NOTE 12 These maximum bending strain values do not apply to local strain, such as at carcass/pressure sheath interface. Table 9—Annulus Classification and Associated Design Requirements Class Annulus Containing Armor Wires (1) (2) (3) Cross Section Design End Fitting Design Test Requirement 0 Annulus shall be deliberately flooded. Annulus pressure in equilibrium with the environment. All failure modes related to flooded annulus shall be considered during design as normal operation case. End fitting design and/or flexible pipe body designs shall have an arrangement ensuring free flooding of the annulus during installation but with controlled oxygen renewal in operation to mitigate associated risk of accelerated corrosion. Verification of flow through the flooding system shall be verified prior to delivery. 1 No specific requirement on annulus status. All failure modes related to flooded and dry annulus shall be considered during design as normal operating case. No particular design arrangement, the annulus status is not guaranteed and no reinforcement or sealing of the external sheath is required (only anchoring in the end fitting is compulsory). No additional test requirement beyond those specified in 9.5 when applicable. 2a Annulus should not be flooded; however, possibility of seawater ingress is accounted for in design, and associated engineering criterion are fulfilled in deaerated-seawater-flooded annulus conditions as normal operating case. Flexible product shall be designed with a leakproof sheath above the tensile armors. Per Section 9, Table 21. The end fitting shall be designed to avoid the ingress of seawater through any of its ports or sealing interfaces with at least one qualified barrier. The sealing performance of the leakproof sheath at the end fitting shall Class Annulus Containing Armor Wires (1) (2) (3) Cross Section Design End Fitting Design Test Requirement be qualified for the entire service life. 2b Annulus should not be flooded; however, possibility of seawater ingress is accounted for in design, and associated engineering criterion are fulfilled in deaerated-seawater-flooded annulus conditions as accidental case. Flexible product shall be designed with a leakproof sheath above the tensile armors. Additional mechanical protection on top of the leakproof sheath is recommended. The end fitting shall be designed to avoid the ingress of seawater through any of its ports or sealing interfaces with at least one qualified barrier. The sealing performance of the leakproof sheath at the end fitting shall be qualified for the entire service life. Gas release valve (GRV) and inspection devices shall be qualified to resist operating conditions for the entire service life. Per Section 9, Table 21. Annulus sealing test (9.6) and end fitting sealing tests (9.7) are mandatory. 3 Annulus should be dry since project design requirements cannot be fulfilled if annulus flooding occurs. Flexible product shall be designed with an additional mechanical protection on top of the leakproof sheath, and this leakproof sheath shall have the same repair constraints as the internal pressure sheath as defined in 7.9. In addition to the requirements of Class 2b defined above, all end fitting ports and seals shall be designed with two qualified barriers for redundancy. GRV and inspection devices shall be qualified to resist operating conditions for the entire service life. Per Section 9, Table 21. Annulus sealing test (9.6) and end fitting sealing tests (9.7) are mandatory. NOTE 1 For insulated lines, the separate outer annulus including the thermal insulation can be flooded provided the classification of the annulus containing armor wires is preserved. For smooth bore pipes with an anti-collapse sheath, the pressure armor annulus and the tensile armor annulus may fall into different classes. NOTE 2 Annulus condition monitoring or inspection should be considered by purchaser as per API 17B. NOTE 3 For flexible pipe systems with multiple sections, each individual section may fall in a different class. 36 5.2 API SPECIFICATION 17J Pipe Design Methodology The design methodology shall include the following, as a minimum: a) theoretical basis, including calculation procedures for the pipe design parameters; b) calculation method for all pipe layers and components; c) verification of the theoretical basis with prototype tests. The verification shall include the capacity of all pipe structural layers. Simplified conservative analysis methods for checking of noncritical layers, such as antiwear layers, are acceptable if the method does not influence the reliability of the calculation of stresses in the other layers; d) basis for stress concentration factors used for the steel materials, including stress concentrations at and within the end fitting interface, at clamped accessories, and due to contact with rigid surfaces, manufacturing tolerances, and load-induced gaps; e) manufacturing tolerances, manufacturing-induced stresses or strains, welds, and other effects that influence structural capacity or material behavior when exposed to the operating environment; f) verification of the service life methodology, subject to the requirements of 5.3.4; g) all layer material properties in accordance with Table 13, Table 14, and Table 15; h) qualification of materials in accordance with Table 16 and Table 17 for the pipe and in accordance with 6.2.5 for the end fitting. Initially and whenever revisions occur, the pipe design methodology shall be verified by an IVA in accordance with the requirements from Section 11. The IVA shall establish the range of applicability for each design methodology and each manufacturing site and this shall be communicated to purchaser for each flexible pipe design. The IVA shall verify that the manufacturing process is controlled such that the design requirements are met within the range of applicability of the design methodology. The IVA shall issue a type approval certificate (TAC) and its associated report describing the limits and constraints of the design methodology as per 11.2. The TAC and its appendices shall be available for review by the purchaser. The design methodology shall account for the effects of wear, corrosion, manufacturing processes, dimensional changes, creep, and aging (due to mechanical, chemical, and thermal degradation) in all layers, unless the pipe design is documented to not suffer from such effects. The following effects of corrosion shall be accounted for the purpose of stress calculation for extreme and fatigue local analyses: — loss of wire cross section from metal loss, — reduction of wire load capacity, — increased mean stress and dynamic stresses, — increased surface roughness, — reduced fatigue resistance from local stress concentration and crack initiators. The utilization levels of Table 8 are based on nominal dimensions and EOL conditions. For the metallic and anti-buckling layers, it shall be shown that variations in dimensions within manufacturing tolerances do not change utilization values by more than 3 % above the values specified in Table 8. Manufacturers may lean on SPECIFICATION FOR UNBONDED FLEXIBLE PIPE 37 manufacturing experience (e.g. process control data or statistical data or processes) or IVA review to avoid an unrealistic combination of maximum individual tolerances when demonstrating that as-built values do not exceed the 3 % threshold. The calculation of the thickness for all metallic layers shall include allowances for wear and uniform corrosion rates calculated for the service life. For a new pipe design, the manufacturer shall perform a failure mode effects and criticality analysis (FMECA) and identify the potential failure mechanisms and failure modes, planning and taking actions to mitigate them in the design methodology, including sufficient material and prototype tests and material characterization/qualification tests to verify the design methodology and obtain a revision or amendment of the TAC by an IVA as described in 11.2. The qualification program shall be based on FMECA and its implementation and results reviewed in the IVA report, considering a comprehensive scope and mitigation measures outlined in API 17B. The manufacturer shall revise or amend the fabrication specification such that the design requirements are met within the range of applicability of the design methodology. The material and prototype tests shall verify fitness-for-purpose for those design parameters that are outside the previously validated envelope. See API 17B for guidelines on the tests that should be performed and recommendations on the test procedures. 5.3 Flexible Pipe Design 5.3.1 Design Criteria The pipe layers shall be designed to the criteria specified in Table 8, subject to the requirements of Section 5. The utilization for the internal pressure sheath shall be calculated based on both the maximum allowable creep and maximum allowable strain of the polymer material, subject to the requirements of 5.3.2.1. The manufacturer shall evaluate buckling failure modes in the carcass, pressure armors, and tensile armors and shall confirm by analysis validated by testing that the layers meet the design requirements. Hydrostatic collapse calculations for the carcass can account for the support provided by the pressure armor layer. The buckling load utilization for the internal carcass shall be calculated as the differential pressure divided by the hydrostatic collapse resistance. The methodology for the calculation of hydrostatic collapse resistance shall be documented and based on the minimum value obtained using a validated design methodology, taking into account all sources of ovalization (i.e. from manufacture, test, installation, operation) and loading in pipe’s axial and radial directions. When applicable, the manufacturer shall evaluate the collapse failure mode associated with the buildup of gas pressure between the pressure sheath and the adjacent sacrificial layers and shall confirm by analysis that all design requirements are met. The manufacturer shall also verify the pipe performance against the pressurization rates determined as per 4.4.2. The manufacturer shall specify any operational limits on pressurization and depressurization rates as a result of this failure mode. The utilization for the pressure and tensile armor layers shall be calculated as one of the following: a) stress utilization: stress divided by structural capacity where stress is the calculated average stress in the actual layer; b) load utilization: applied load divided by load to cause yielding or instability; c) the stress shall be calculated using the verified design methodology, see 5.2, subject to the design requirements of 5.3.2. The calculated value shall include dynamic loads and be based on average stress in the layer. The average stress shall be calculated based on distributing the total layer load uniformly over all wires in the layer. The structural capacity shall be selected either as 0.9 times the ultimate tensile strength or as the yield strength. The structural capacity shall not exceed 0.9 times the ultimate tensile strength. The 38 API SPECIFICATION 17J structural capacity used for design shall be either the minimum specified value, or the minimum value as certified by the supplier, provided that it exceeds the minimum specified value. Local armor wire stresses may exceed average layer stresses during operation and also structural capacity during manufacturing. As detailed in 5.3.4.3, fatigue and environmental assisted cracking analyses shall be based on local armor wire stresses. Damage mechanisms resulting from local wire stresses exceeding the average stress in the layer in operation or the structural capacity during manufacturing shall be addressed in design, and these local stresses checked as being acceptable regarding the fluid compatibility, the structural capacity and service life of the pipe. Potential damage mechanisms include: a) gross yielding or deformation of armor wire cross sections, b) crack initiation in higher stress concentration areas of armor wire cross sections, c) crack initiation in corrosive environments. For methodologies on evaluation of acceptability of local stresses, refer to API 17B, Section 5.4.1. The utilization for the outer sheath shall be calculated based on Table 8 requirements, subject to the requirements of 5.3.2.2. The SR shall be calculated as the MBR that satisfies all the requirements of Table 8. The bend radius required to cause locking in the interlocked layers or blocking at the intrados of the non-interlocked pressure armors layer shall be calculated [locking radius (LR)]. The SR shall be at least 1.1 times the LR. The SR shall not cause damage or disorganization to other layers. Table 10 outlines the MBR criteria with respect to the SR and LR that shall be satisfied for different load conditions and load type combinations. In addition, for all load conditions and combinations, the MBR must not be less than SR. Note that a larger MBR than the criteria of Table 10 may be required to comply with the design criteria in Table 8 or with the fatigue design requirements and factor of safety shown below. SPECIFICATION FOR UNBONDED FLEXIBLE PIPE 39 Table 10—Minimum Bend Radius Design Criteria Load Condition Loading Type Operating Permanent Nonoperating Abnormal Temporary All types 1.0 × storage minimum bend radius (SR) Static (1) 1.1 × locking radius (LR) Dynamic supported (2) 1.1 × 1.1 × LR Quasi-dynamic (3) 1.25 × 1.1 × LR 1.1 × 1.1 × LR Dynamic (4) 1.50 × 1.1 × LR 1.25 × 1.1 × LR Survival 1.1 × LR 1.1 × LR NOTE 1 Static: flexible pipes not exposed to significant cyclically varying loads or deflections during permanent operations. Such application is therefore limited to flexible pipeline without cycles or few cycles, e.g.: a) static flowline on seabed, possibly subject to pipeline end termination/in-line tee excursions (during shutdown or start-up); b) static risers subject to excursion due to current (typically static riser on fixed platform into I-tube). NOTE 2 Dynamic supported: service in which flexible pipe is exposed to large number of cyclically varying loads and deflections during permanent operations (typically above 105 cycles). Nevertheless, the flexible is supported by a rigid support or body, e.g.: a) flexible on arch, b) flexible on bellmouth, c) flexible on a gutter or a chute (typically during installation), d) flexible on bending restrictor. Flexible MBR in supported area is then assumed to be well known and controlled. For flexible on arch, it is combined radius from deflector and gutter that shall be considered to meet criteria of this table (considering only one if the two is not enough conservative). Bending stiffener is not considered as dynamic supported application. NOTE 3 Quasi-dynamic: service in which flexible pipe is subject to quasi-dynamic loading, which includes: a) no direct wave load on the flexible: this should be interpreted as flexible pipe subject to few cycles or low-frequency cycles (<105 cycles) and independent from sea state, e.g. subsea flexible jumper at bottom hybrid riser or flexible pipe at the exit of a I-/J- tube installed on a static platform; b) predominantly displacement controlled: this should be the case of flexible pipe subject to cyclic conditions into confined area, e.g. flexible pipes for spiral stack turret application. It should be considered also as “quasi-static application.” NOTE 4 Dynamic: service in which flexible pipe is exposed to a large number of cyclically varying loads and deflections during permanent operations. Such application is therefore subject to large number of cycles (typically above 105 cycles) with high frequency (several cycles per minute), e.g.: a) dynamic risers; b) dynamic jumpers from floating unit to hybrid riser; c) oil offloading lines from floating unit to offloading buoy. Fatigue life calculations shall be performed for intact annulus and annulus flooded with deaerated seawater conditions in accordance with the requirements of 5.3.4. For metallic armoring layers, the predicted fatigue life shall have a factor of safety of at least 10 times the service life. A reduced fatigue safety factor can be used if it can be documented based on analysis that a failure probability of 10–5 in the last year of operation is maintained. For the internal pressure sheath, the fatigue design methodology where calculated according to 5.3.4.6 shall use an independently verified fatigue safety factor with a documented basis. This fatigue safety factor for the internal pressure sheath shall be at least 10 times the required service life. A lower fatigue safety factor may be used upon agreement with the purchaser for: a) metallic armoring layers for annulus flooded with deaerated seawater condition and/or b) the pressure sheath. 40 API SPECIFICATION 17J Reliability-based design may be applied as an alternative design method. All relevant design criteria for the reliability-based design cases should then be considered. The safety level applied (DNV-RP-F204 safety classes can be used as the default starting point) shall be approved by the purchaser. Fatigue safety factor reliability methodology is described in a case study in the Handbook on Design and Operation of Flexible Pipes. 5.3.2 5.3.2.1 Design Requirements for Pipe Layers Internal Pressure Sheath Load Case Analysis As a minimum, the internal pressure sheath shall be analyzed for the most critical simultaneous combination of internal pressure, temperature, operating MBR, and polymer conditions, with annulus at atmospheric pressure or intact annulus or annulus flooded with deaerated seawater, for the operating and nonoperating (temporary) load conditions. Cyclic Loading Effects The analysis shall include relevant cyclic loading effects such as hysteresis, relaxation, shrinkage, loss of plasticizer, diffusion of fluids, and absorption of fluids into the polymer matrix. As a minimum, the following shall be included: a) creep and strain at operating temperature ranges due to bridging of gaps in the reinforcement layer; b) stress variations from pressure and temperature cycling caused by the fluids inside the pipe bore and the pipe annulus, including unpressurized-pipe scenarios; c) contact pressure from the adjacent (carcass and armor) layers, considering the influence of the pressure armor gap distribution; d) creep and strain at operating temperature ranges, due to pipe bending, axial elongation and compression, torsion, and radial expansion; e) weight of all layers adjacent to the pressure sheath that are not independently supported in the end fitting; f) changes in material performance or properties due to aging. Wall Thickness Calculation The methodology used for calculating the wall thickness of the internal pressure sheath shall be validated by documented tests or field experience and shall comply with the following minimum requirements. a) The gap between pressure armor or tensile armor wires, as applicable, used in the wall thickness calculations shall be the maximum gap while bending to the operating MBR (including additional assessment for SR considering hydrotest FAT pressure to be done according to Table 2 and 4.4.2) and accounting for manufacturing tolerances. b) The analysis shall account for thinning of the polymer layer due to bending to the operating MBR (including additional assessment for SR considering hydrotest FAT pressure to be done according to Table 2), stress concentrations due to thickness variations, effect of deplasticization, swelling and aging on material properties, manufacturing tolerances, creep behavior of the polymer material, and termination of the layer in the end fitting. SPECIFICATION FOR UNBONDED FLEXIBLE PIPE 41 Mechanical Properties The manufacturer shall show through analysis (with a methodology validated by testing) that with the minimum mechanical properties of the material and maximum gap in the supporting layer: a) no failure due to deformation of the polymer into gaps in the adjacent metallic layers shall occur. All deformation calculations shall be based on pressure difference across the internal pressure sheath. Minimum mechanical properties shall take account of the impact of temperature and fluid absorption; b) the material is capable of handling the associated loads without failure at design minimum temperature and maximum associated pressure; c) the material is capable of withstanding void growth, whitening and crazing within the range of operation, design and test conditions. Cracks The manufacturer shall verify that crack initiation, due to notch sensitivity and stress concentration, does not occur in the material used for the internal pressure sheath. Particular attention should be paid to the potential stress raisers and defects caused by the manufacturing of the main pressure sheath and to any machining marks resulting from end fitting mounting. For dynamic applications, the effect of sacrificial layers used in multiple internal pressure sheath constructions shall be accounted for. The thickness of the structural pressure sheath layer made of materials susceptible to crack growth (e.g. PVDF) shall be sufficient to ensure that crack growth will not propagate through the thickness of the layer due to thermal cycling, see 4.4.3 f), under typical operating conditions, should the crack initiation occur. Sufficient layer thickness for such materials shall be demonstrated. Manufacturer shall document the methodology, tools, and test data (e.g. thermal cycling through notched samples until failure) used to confirm that a crack growth will not propagate through the thickness of pressure sheaths made of materials susceptible to crack growth (e.g. PVDF) and make them available for review. Collapse For smooth bore pipes without anti-collapse sheath, collapse resistance shall be considered in design. When assessing the collapse resistance of pressure sheath, then manufacturers shall consider the elements presented in 5.3.2.4 a) where applicable, including material change due to temperature and aging. Pressure sheath collapse shall not be accepted in normal service of smooth bore pipes. For survival cases, requirement for collapse assessment shall be agreed mutually by purchaser and manufacturer. Multiple Layers If the internal pressure sheath is composed of multiple layers, then dissimilar materials shall not be used in the multiple layer construction, unless there is documented test evidence that the materials fulfil the design requirements for the specified life and service conditions. The manufacturer shall demonstrate that the pressure buildup and resulting pressure differentials within the flexible pipe structure associated with the design depressurization rates will not lead to collapse of the carcass, permanent damage in the internal pressure sheath, or unacceptable health, safety, and environment (HSE) risks for installation, storage, and retrieval operations. A means for prevention of unacceptable gas buildup between adjacent layers shall be incorporated into the design. Manufacturers shall have either design methodology to demonstrate through analysis or full-scale test that multilayer PVDF liners will not cause the collapse of the pipe carcass due to gas flow buildup circulating between sheathes. 42 5.3.2.2 API SPECIFICATION 17J Outer Sheath The design of the outer sheath shall account for changes in material performance or properties due to diffusion/absorption of fluids into the polymer matrix and aging, manufacturing imperfections such as notches and cusps, creep and strain at operating temperature ranges due to pipe bending, axial elongation and compression, torque loads, external and annulus pressure, creep into the gaps in the outer tensile layer, installation loads, local loads from ancillary components, and temperatures due to adjacent components such as active heating, fiber optic and electric cables and hydraulic hoses in a combined flexible pipe and umbilical structure, insulation from attached appurtenances, soil from self-burial and/or voluntary embedment, and marine growth. The design of the outer sheath shall also account for the abrasion and wear of the polymeric material due to contact combined with motion. This may apply to the soil and ancillary equipment such as bend stiffener internal components, bellmouths, I-tubes, MWA support gutters, and seabed anchors. It may also apply to equipment in the pipe laying vessel. Ancillaries and equipment shall be designed to minimize wear. Protective sheath shall neither be sealed nor watertight. The protective sheath shall be secured from axial slippage during installation and operation. Creep of protective sheath shall be considered. Any outer sheath section exposed to UV radiation shall be UV protected throughout its service life, unless proven UV resistant to local field conditions based on UV testing or on predictions validated by testing as in Table 16. It shall be documented that the outer sheath can resist the differential pressure between the annulus and the external environment in all locations, including during installation and retrieval operations for dry, wet, or flooded annulus conditions. The hoop stress induced by the differential annulus pressure shall be calculated by manufacturer, and it shall be demonstrated that the calculated stress is acceptable for the outer sheath in installation, testing, operation, and retrieval for SOL and EOL conditions. The criterion for hoop stress resistance shall be reviewed by IVA. Wear and impact assessment shall be undertaken to verify outer sheath thickness is adequate for the design conditions and to verify the need for any further protective measures per 5.3.2.7. 5.3.2.3 Intermediate Sheath If an intermediate sheath is designed to prevent leakage of annulus fluid outside the layer or to prevent seawater ingress beyond this layer, then the design of this sheath shall meet the requirements of Table 8 for the anti-collapse sheath and also the requirements of Table 9 for sealing tests at the end fitting level. It shall be documented that the leakproof intermediate sheath can resist the differential pressure between the annulus and the external environment in all locations. For dynamic applications, intermediate sheaths shall withstand wear due to relative motion between layers. Wrinkles and cracking due to bending should be avoided. For smooth bore pipes used for gas or gas/liquid applications, design requirements for the anti-collapse sheath shall be agreed between the purchaser and manufacturer. In the case of perforated intermediate sheaths (for insulation), the size and spacing of the holes needs to consider the shielding by tensile armors. The design shall be based on the most onerous combination of annulus environment, temperature, and pressure on both sides of the layer. For designs where the intermediate sheath creates a second annulus space, design measures shall be taken to avoid gas trapping and pressure buildup that may lead to unacceptable HSE risks during installation, storage, and retrieval. Guidance for manufacturing QA and FAT requirements are provided in API 17B. SPECIFICATION FOR UNBONDED FLEXIBLE PIPE 5.3.2.4 43 Internal Carcass The design of the internal carcass, and carcass insert when applicable, shall account for the following: a) collapse assessment shall consider the below input parameters occurring at the same phase: i) minimum specified internal pressure; ii) maximum external pressure acting on the internal pressure sheath accounting for hydrostatic pressure, annulus pressure (including accounting for a flooded annulus), pressure buildup between polymer layers (in flexible pipes with intermediate leakproof sheath and/or multilayer sheath constructions), contact pressures from outer layers, and presence of gaps between carcass and pressure armor not filled by polymer shall be accounted for; iii) maximum pipe ovality including residual ovalization from the installation method; and iv) pipe bent to the minimum operational bend radius; b) fatigue in the carcass; considering carcass manufacturing tolerances and interaction with adjacent polymer layers; c) effects induced by thermal expansion and contraction, plasticizer loss, pressure loads, and/or swelling of the internal pressure sheath; degradation of intermediate tape layer; d) erosion and corrosion. The manufacturer shall evaluate the erosion and corrosion rates for the specified fluid velocities and content over the service life of the pipe and shall document that these rates do not cause failure of the carcass. The allowable erosion shall be validated in accordance with the requirements of 6.2.4.5. Erosion evaluations should be based on DNV-RP-O501; e) for each flexible pipe that is servicing a gas duty with less than 1 % liquid volume fraction (LVF < 1 %), a screening (i.e. of flexible pipe system with its boundary conditions) to determine the risk of FLIP shall be executed. All stable operating conditions within the service life of the system, including those of short durations (several hours), shall be considered within the FLIP screening; f) unlocking due to local pressure difference across a blockage. The manufacturer shall document the mechanical capacity and safety factor of the carcass to withstand unlocking for flexibles at risk of experiencing blockages (such as hydrate formation in lines transporting hydrocarbons, CO2, etc.; or wax formation; or other cases where any blockage may be suspected). 5.3.2.5 Pressure Armors The pressure armors shall be designed for the required hoop strength and shall account for the control of gaps between wires, the prevention of loss of interlock (when applicable), calculated plastic deformation, and residual stress and accumulated plastic strain from the manufacturing process and from FAT and other leak tests. 5.3.2.6 Tensile Armors The tensile armors shall be designed for the required axial strength. The design shall also account for any requirements for torsional properties, control of gaps between wires, and hoop strength, in particular for pipe designs that do not include pressure armors, and shall account for plastic deformation and for residual stresses from the manufacturing process (inclusive of the stress relaxation during FAT and other pressure tests) applicable to all load cases and inclusive of tensile armors within the end fitting. Consideration of pipe torsion (limp and stiff direction) shall be accounted for in handling and transpooling activities. 44 API SPECIFICATION 17J Tensile wires may also need to be designed (i.e. wire geometry and lay angle as well as number of layers) for lengthwise stability (e.g. for buried pipe), as well as for resistance to wire lateral buckling and/or radial buckling (birdcaging). The complete pipe structure shall be designed in such a way that the torsional balance and axial compression strength characteristics of the pipe meet the functional requirements. 5.3.2.7 Additional Layers Thermal insulation layers shall be designed in accordance with the requirements of 5.4.3. Antiwear layers shall be designed, by accounting for aging, creep, and wear, to prevent wear between adjacent steel and/or extruded polymer layers for the specified service life, and shall not serve as a sealing layer. The consequences of additional stresses occurring in the tensile armor layers due to local failure of the antiwear layer shall be evaluated and documented as an accidental load case. Additional external-protection layers, whether polymer or metallic, shall be designed to prevent external damage, wear, or excessive hoop stress occurring in the outer sheath, based on the design conditions specified by the purchaser, and shall be designed for the temperatures due to adjacent components such as active heating, fiber optic and electric cables and hydraulic hoses in a combined flexible pipe and umbilical structure, insulation from attached appurtenances, and soil from self-burial and/or voluntary embedment. The effect of adding external protection and the resulting pipe performance properties for the final assembly shall be documented, including bending properties where time dependency, temperature dependency, and strain dependency shall be addressed. External protection layers shall not be sealed. Protective layer shall be secured from axial slippage during installation and operation. Creep of protective sheath shall be considered. Anti-buckling tapes shall be designed for the required strength to resist the radial buckling of the tensile armor layers. The manufacturer shall demonstrate that the selected materials have the sufficient long-term mechanical capability. The design criteria for allowable stress or strain in the anti-buckling tapes shall be in accordance with Table 8. The cumulative radial gap between each tensile armor layer and its adjacent layers shall not exceed half the wire thickness for a pipe subject to axial compression loading (i.e. no bending). The tape structural capacity shall be defined as the minimum strength during the pipe service life derived after accounting for aging and wear. Active heating, fiber optic, electric cables, hydraulic hoses, plastic fillers, and steel tubes in a combined flexible pipe and umbilical structure, such as an integrated pipe umbilical (IPU) described in API 17B, should be designed in accordance with API 17E. 5.3.3 End Fitting The end fittings shall be designed for reliable termination of all pipe layers, such that leakage, structural deformation, or pull-out of wires, carcass, or extruded layers does not occur for the service life of the pipe, taking account of all relevant factors, including corrosion, shrinkage, creep, aging, and pressure effects. The end fittings shall be designed for the thermal and pressure cycles defined for the service conditions of the particular dynamic or static application, taking into account all effects listed in 5.3.2. The design methodology for end fittings shall be documented, verified by documented tests and analyses, and shall be made available for review by purchaser. The methodology shall account for the manufacturing tolerances and material degradation over the service life. The design shall account for supporting loads from any ancillary components attached to the end fitting, including bend stiffeners. The design shall also account for temporary or permanent hangoff loads into the end fitting, such as J-tube/I-tube hangoff, or hangoff during vertical lay operations. SPECIFICATION FOR UNBONDED FLEXIBLE PIPE 45 The inner end fitting sealing system is to be designed to the design pressure and the design external pressure. Whenever a sheath is required to be sealed in the end fitting, the design shall be based on the most onerous combination of bore fluid, annulus environment, temperature, and pressure on both sides of the layer. The design of the end fitting crimping/sealing mechanism shall ensure that the combined strain induced by the in-service pull-out forces and installation of the end fitting seal ring does not result in failure of any of the sheaths over the service life. The methodology shall account for manufacturing tolerances and material degradation. Whenever required by Table 9, end fitting design and analysis shall demonstrate that there is always a net sealing pressure at the seal between the outer sheath and the end fitting housing. The analysis is to consider the effects of external pressure, water depth, temperature, and long-term creep/relaxation of the outer sheath material. Any difference between the inner diameter of the end fitting bore and the inner diameter of the flexible pipe shall be clearly documented and conveyed to the purchaser for sizing and design of pigs. In the design of the end fitting, axial movements of the carcass relative to the end fitting shall be mechanically restrained. Accounting for all physically possible load combinations, the design requirements in Equations (1) and (2) shall apply for the pressure-containing parts of, and components subject to tensile loading in, the end fittings: σ t ≤ n ×σ y (1) σ e ≤ n ×σ y (2) where σ t is the tensile hoop stress; σe is the equivalent stress (Von Mises or Tresca); σ y is the material yield stress; n is the permissible stress utilization factor as specified in Table 11. Accounting for all physically possible load combinations, the design requirements in Equation (3) shall apply for the end fitting anchoring system: F ≤ n × Fy where F is the design pulling force resulting from design tension and pressure; Fy is the anchoring system capacity; n is the permissible anchoring system load utilization factor as specified in Table 11. (3) 46 API SPECIFICATION 17J Table 11—End Fitting Permissible Utilization Factors Operating Conditions Component Failure Mode Design Criteria Nonoperating Conditions Permanent Normal Extreme Temporary Abnormal Normal Installation Test Survival Extreme Burst, tension, Pressure-containing bending, and part torsion Stress 0.67 0.85 0.85 0.67 0.91 0.85 0.97 Tensile armor (1) Stress 0.67 0.85 0.85 0.67 (2) 0.91 0.85 0.97 Load 0.67 0.85 0.85 0.67 (2) 0.91 0.85 0.97 Tensile armors anchoring system Breakage — — — Pull-out Breakage Pull-out due to failure of potting compound NOTE 1 Design procedures shall consider any changes to steel resistance coming from the mounting process such as microstructure changes from heating/welding or insertion of microcracks or other defects. NOTE 2 Higher utilization factor up to 0.85 may be considered if approved by the purchaser or independent verification agent. For dynamic applications, fatigue life calculations shall be considered for the termination of all metallic and pressure sheath layers and shall be performed as required for the pipe body in 5.3.1. The thickness of weld overlay material may be included in the wall thickness in end fitting analyses, provided that the material strength of the weld overlay material is equal or greater than the strength of the parent material and that a validated weld procedure is documented. The manufacturer shall calculate the burst pressure of the pipe body structure and of the end fitting. This calculation is done based on minimum guaranteed material properties. The manufacturer shall state if the end fitting has a lower calculated burst pressure than the pipe body. The manufacturer shall have a validated methodology for the determination of the anchoring system capacity. The manufacturer shall calculate the failure tension capacity of the pipe structure and the end fitting anchoring system capacity. The manufacturer shall state if the anchoring system capacity of the end fitting is lower than the failure tension of the pipe body. When the bend stiffener is mounted onto the end fitting, the design methodology shall consider the effect of transition from the pipe body to a fixed condition inside the end fitting in the stress evaluation of the tensile armors. The effect of any device used inside the end fitting or temporarily used during the assembly to organize the tensile armors or to help in the assembly process shall be accounted for in the design. For pipes with multiple outer sheaths and pipes with insulation layers that may have stiffness transitions that attract curvature, the manufacturer shall specify such stiffness transitions enabling manufacturer and/or purchaser to demonstrate that the transition from end fitting to pipe body will not result in concentrated curvatures that violate specific MBR as defined in Table 10 at or near the end fitting. Such transitions shall not impact the sealing performance. SPECIFICATION FOR UNBONDED FLEXIBLE PIPE 5.3.4 5.3.4.1 47 Service Life Analysis Service Life—Static and Dynamic Applications The service life analysis of flexible pipes shall document the properties of the pipe materials for the specified service life, in accordance with the requirements of Section 6. The minimum strength for metallic materials, during the service life of the pipe, shall be used in the design calculations. Polymer materials shall be demonstrated to meet the design requirements of 5.3.2 over the service life. Operating profiles of pressure and temperature can be considered for fatigue, permeation, and aging designs. The analysis shall include as a minimum the following: a) for polymer components, creep, aging, dimensional changes (shrinkage, swelling), and strain to failure in the operating environment; b) wear, corrosion, and erosion of steel components. For annulus flooded with deaerated seawater conditions, the effect of corrosion of steel components in the annulus shall account for permanent contact with seawater and corrosive gas ingress rate. Determination of salinity and corrosive gas ingress rate shall consider the presence of multiple exterior sheath layers and insulation, when applicable. The manufacturer shall establish a maximum time to repair and the service life associated with the event of outer sheath damage leading to aerated seawater in the annulus. Intact annulus conditions shall consider condensation of permeated fluids in the annulus that occurs due to all operating temperature scenarios, including shutdown and restart. The design method shall predict the period of time in which the annulus contains condensed fluid. For this period, fatigue calculations shall be based on S-N curves that reflect this environment, as applicable. Otherwise, the manufacturer shall design the pipe assuming this environment for the entire service life. The general corrosion rate and CF resistance shall be documented and used to identify a minimum and most likely service life based upon expected normal operating conditions, assuming the pipe annulus is flooded with seawater during installation and/or during wet storage or during dry storage and, if applicable, according to the specified annulus class as defined in Table 9. Environmental assisted cracking, other than CF, shall be avoided. The corrosion rate in the presence of aerated or deaerated seawater shall be documented based on testing for each material at equivalent operating conditions and validated by IVA. The expected corrosion rate should be larger than the general corrosion rate due to the effects of crevice corrosion (and level of protection from the cathodic protection system, if any) on steel surfaces in contact or when steel interfaces polymeric tapes. The expected corrosion rate applied on the steel surface of the armor wire shall represent local corrosion at the most unfavorable position within the most loaded part of the wire considering the effects from crevice corrosion from steel/steel or polymer/steel surfaces in contact. For such cases, the manufacturer shall develop representative small-scale (if valid) or full-scale tests to validate the corrosion rate assumed in pipe design, considering also the particular constructive characteristics and type of interfaces that can impact corrosion rate in the tensile armor anchoring system in the end fitting. The fatigue life analysis shall also confirm that the internal and intermediate pressure sheaths and outer sheath maintain integrity under the calculated alternating strains. Refer to API 17B, Section 6.6.6 for further guidance on fatigue resistance. 48 5.3.4.2 API SPECIFICATION 17J Service Life—Dynamic Applications Only For dynamic applications, the requirements of 5.3.4.3 and 5.3.4.4 shall apply. In addition, a fatigue analysis shall be performed for pressure armor layers and tensile armor layers that shall take account of all mechanical and dynamic effects that can introduce failure modes into the pipe in the dynamic application. As a minimum, the effects of residual wires stress, wear, fatigue, fretting, material degradation, including corrosion, and degradation and draining of lubricant shall be accounted for. Welds in the pressure and tensile armor wire shall be avoided in the fatigue-critical areas identified by design analysis (e.g. bend-stiffener region). If welds on the pressure and tensile armor wires cannot be avoided in the fatigue-critical areas, these welds shall be proven to have adequate fatigue performance by analysis and SN testing for the same annulus condition. Risk of fretting fatigue of the pressure armor layer shall be evaluated for dynamic risers considering layer geometry and contact forces. Risk may be evaluated based on similar design track record, tension, and pressure levels. If the risk is relevant, models validated by experimental test results may be used for further assessment. Service life shall consider, subject to the requirements of 5.3.1 and 5.3.3: a) degradation of polymer layers in accordance with the requirements of 5.3.4.5; b) assessment of service life for pressure sheaths in accordance with the requirements of 5.3.4.6; c) assessment of service life for pressure and tensile armors based on S-N data as per 6.2.4.6; d) the annulus environment based on permanent operating conditions, in accordance with the requirements of 5.1.4, 5.3.4.1, 5.3.4.2, and 5.4.4; e) the expected changes in cross-sectional dimensions surface conditions and fatigue performance of pressure and tensile armors resulting from wear and corrosion during the service life. A verified model shall be required to assess the H2S and CO2 partial pressures with the associated pH level in the annulus during the service life. See 5.3.5. If the endurance limit cannot be supported by tests, then an S-N curve without an endurance limit shall be used. 5.3.4.3 Fatigue Analysis of Armor Wires in the Pipe Body For dynamic applications, fatigue calculations using Palmgren-Miner linear damage theory and S-N data in accordance with 6.2.4.6 shall be performed for the pressure and tensile armors. If it has been demonstrated from testing in accordance with 5.3.4.2 and 6.2.4.6 that wire stresses are below a documented and verifiable endurance limit established by testing and approved by the purchaser, Miner’s calculations are not required. The design S-N curves, used in the fatigue analysis of the structural pressure and tensile layers for in-air, intact annulus and annulus flooded with deaerated seawater, shall be based on fatigue test data with a statistically significant lower bound design curve that provides 97.5 % probability of survival. The effects of mean stresses shall be considered. The S-N curves shall be either developed or corrected for these mean stress conditions. The fatigue analysis shall be performed at all critical structural or geometric locations and shall be based on local armor stresses. Local wire stress shall be calculated based on determining the stress at the critical locations of a wire inclusive of the effects of pipe bending and accounting for friction-induced axial stresses. SPECIFICATION FOR UNBONDED FLEXIBLE PIPE 49 Residual stresses from manufacturing and the effects of FAT and pressure testing contributing to the mean static stress shall be accounted for. Any beneficial effect of having hydrostatic water pressure in the annulus, such as on the local stress analysis, shall only be considered for conditions that can be guaranteed during installation or operation, as applicable. 5.3.4.4 Fatigue Analysis of Armor Wires in the End Fitting Fatigue analysis of the armor wires in the end fitting shall be in accordance with the requirements of 5.3.4.3. The fatigue analysis shall account for changes in wire strength, residual stresses and stress concentrations, and wire deformation due to the mounting process. The fatigue analysis shall also consider aspect related to the movement of armor wires when cyclic bending is applied close to end fitting interface. The design methodology shall consider tensile wire geometry, e.g. fishscaling, inside the end fitting, if applicable. 5.3.4.5 Aging Service life assessment shall be performed for any extruded sheaths, anti-buckling layers, antiwear layers, and nonmetallic sealing elements in the flexible pipe structure, taking account of the impact of design operating conditions (e.g. temperature, pH, water cut, methanol, glycol, and other known exposure profiles) on the long-term deterioration of each of those layers. The aging and deterioration of these layers shall be demonstrated to be suitable for all applications based on known chemical and physical aging mechanisms. Aging of polymer layers shall be checked for both maximum and minimum thermal insulation including effect from marine growth, burial, bend stiffeners, and other accessories. Guidelines on aging of PA-11 or PA-12 as internal pressure sheath are given in API 17TR2. Total acid number should be considered when evaluating aging of the PA-11 or PA-12 polymer material. More detailed requirements on aging tests are listed in 6.2.3.5. 5.3.4.6 Fatigue of Internal Pressure Sheath Fatigue analysis shall be performed for the internal pressure sheath. This assessment shall evaluate the fatigue life of the polymer under the influence of relevant environmental and load conditions as well as the effects of aging, according to 5.3.4.5. The internal pressure sheath fatigue models shall predict the fatigue damage accumulation in the polymer material. The design methodology may be based on laboratory testing, field experience, and full-scale testing. The fatigue damage shall be calculated using design fatigue curves that have been validated for the materials used for the specified cyclic load frequencies and under the applicable service environments. The demonstration of fatigue life shall account for the effects of the manufacturing process and the dimensions of the full-scale product on the materials fatigue life. Small-scale testing to failure shall be used as input for the fatigue design, and full-scale testing shall be used as validation. Polymer grades already tested to previous revision of this standard and used in the field with a well-documented service history can be used without the explicit fatigue analysis as long as the flexible pipe is within a well-documented historical service envelope with respect to temperature, pressure, bore chemistry, annulus chemistry, pressurization and depressurization rates, local notch geometry on both sides of pressure sheath, strain ranges, and corresponding number of cycles. Documentation of the service life of the pressure sheath shall be presented to purchaser. 50 API SPECIFICATION 17J Alternatively, the fatigue assessment may be simplified if it can be demonstrated through small-scale fatigue testing (per the conditions of 6.2.3.7) that the new material performs similar or better in fatigue than existing qualified materials (using validated statistical approach and the Kt value of the materials) at the temperature ranges applicable for the flexible pipe use and that flexible pipe design is the same. The similarity assessment and the applicability of existing qualification/track record shall be validated by the IVA. 5.3.5 Annulus Prediction The manufacturer shall have a methodology to predict the pipe annulus conditions. This design methodology shall be developed using a theoretical basis and validated through experimental data. The annulus prediction model shall be capable of calculating the annulus composition, pressure, temperature, and pH at any point in the flexible pipe. The model shall also consider the change in annulus pressure over time due to the permeation of fluid into the annulus or due to the external hydrostatic pressure. This model shall also take into account the flexible pipe geometry and the gradient of species fugacities this may generate in the annulus. The annulus prediction model shall be able to predict the evolution of the condensation in the pipe cross section and along the pipe length. The manufacturer shall be able to demonstrate, based on the annulus condition, the pipe service life, and the adequacy of materials against applicable failure modes and mechanisms (e.g. SSC, HIC, SCC, corrosion, CF, or aging). The annulus prediction model shall be able to predict multiple phases in the annulus. The model shall also be able to predict the eventual segregation or combination of these phases. This model may also take into account the consumption of species (e.g. H2S) by the corrosion process in the annulus. If the manufacturer does not have a verified model for calculating conditions, then pipe bore partial pressures or fugacities shall be used. The manufacturer shall establish a range of use for the annulus prediction model based on the calibration test results. 5.4 System Design Requirements 5.4.1 General The design of the flexible pipe shall account for all system requirements specified in 4.6, as listed in Table 12, and account for additional requirements specified in 5.4.2 to 5.4.8. The design shall meet all interface requirements specified by the purchaser or by the manufacturer. The flexible pipe shall be designed for the number of deployments and retrieval operations specified by the purchaser per Table 20 and Table A.1. SPECIFICATION FOR UNBONDED FLEXIBLE PIPE 51 Table 12—System-related Pipe Design Requirements General Requirements Flowline Requirements Corrosion protection Flowline routing Thermal insulation On-bottom stability Gas venting Upheaval buckling (lateral pull-back/pull-through) Pigging and through flowline requirements Crossover requirements Fire resistance Interference requirements Piggyback lines Connectors Interface definitions Riser Requirements Inspection and condition monitoring Installation requirements Riser configuration Retrieval requirements Connection systems Exothermal chemical reaction cleaning Vessel data Erosion Interference requirements Abrasion and impact protection Shipping, storage, and handling Load cases Pipe attachments Guides and supports Protection requirements Upheaval buckling, global lateral buckling, upheaval creep, and termination load capacity of fully trenched or partially trenched, buried, or rock-dumped pipes shall be checked for pressure- and temperature-induced axial elongation and forces. The effect of pipe-bending-stiffness variations, resulting from time, temperature, and pressure on the pipe loads, should be analyzed. The analysis shall conclude on necessity of pressure testing the pipe in advance and/or having the pipe pressurized during rock dumping or trenching. Axial forces from soil and rock friction shall not result in detrimental slip between layers. For dynamic riser applications, interference/clashing with other components of the system, including risers, mooring lines, and rigid surfaces such as pontoons, vessels, or platforms, shall be checked in the design. Interference shall establish the most critical conditions for offsets, environmental parameters, marine growth, and bore fluid density. Detailed guidance is provided in API 17B, Section 5.3.4, Riser Interference Design. The friction coefficients between the external sheath and adjacent layers, and between any other pair of layers, for intact and seawater-flooded annulus conditions shall be verified to be adequate for design of installation/retrieval tensioner compression forces and for design of devices to be clamped to the pipe. 5.4.2 Corrosion Protection 5.4.2.1 Galvanic Corrosion Selection of materials shall consider the effect of galvanic corrosion if this can increase utilization factors above allowable limits. If there is the possibility of galvanic corrosion occurring, dissimilar metals shall be isolated from one another with insulation, a coating, or a sufficient corrosion allowance. 52 5.4.2.2 API SPECIFICATION 17J Surface Treatment All external steel surfaces shall be prepared and coated in accordance with internationally recognized or purchaser-specified standards for corrosion protection in all environmental conditions specified in Section 4, unless the material is documented to be corrosion resistant in the specified environment. 5.4.2.3 Corrosion Allowance Requirements for internal and external corrosion allowances shall be evaluated in accordance with the location, conditions of installation, and the requirements specified in Section 4. The manufacturer shall document this evaluation and its effect on the pipe components. Corrosion at the end fitting interface shall not cause damage to any sealing barrier or locking mechanism. Corrosion-resistant overlay or corrosion-resistant alloys may be used in preference to a corrosion allowance. The manufacturer shall have documented records on the suitability of the corrosion-resistant overlay or alloys for the specified application and environment. 5.4.2.4 Cathodic Protection Design of a cathodic protection system shall be in accordance with the requirements of 4.6.1.3. If the cathodic protection system is specified to protect the tensile armors, the anodes electrically connected to the end fitting shall be sized accordingly, and there shall be electrical continuity between the tensile armors and the end fitting. The voltage drop to the adjacent anodes shall be confirmed to be acceptable. The cathodic protection system design methodology shall be documented. See ISO 15589-2 or DNV-RP-B401, and DNV-RP-F103, for guidelines on the design of cathodic protection systems. The cathodic protection system shall consider coating damage breakdown to the end fittings and damage to the outer sheath of a flexible pipe. The extent of coating breakdown, outer sheath damage to be considered, and duration of damaged outer sheath before repair shall be agreed with the purchaser. If a component of the flexible pipe system is reliant on the cathodic protection system of an adjacent structure, then the manufacturer shall have documented justification through calculations in the design report that this adjacent cathodic protection system is both compatible with and has sufficient capacity to give protection for the specified service life. Both the maximum and minimum current conditions shall be checked and particular attention shall be paid to HIC when using high-strength steel. The seawater-exposed surface of the end fitting shall be protected by the cathodic protection system. In case end fittings are exposed to seawater prior to connection, the need for separate anodes on the end fitting shall be evaluated. 5.4.3 Thermal Insulation The materials used for thermal insulation layers shall be selected such that overall heat-transfer coefficient and cooldown times do not degrade below the levels specified in accordance with 4.6.1.4 for the service life. The determination of an acceptable cooldown time shall account for the heat transfer characteristics of the end fitting. When selecting a thermal insulation material, the deterioration of its physical and mechanical properties under a combination of temperature, hydrostatic pressure, seawater-flooded annulus condition, water absorption, and creep of material shall be documented by the manufacturer and accounted for in the design. The design of the thermal insulation system shall be based on the assumption that the outer protective barrier will be damaged or deteriorated, thereby exposing the insulating material to air and/or seawater. Where the SPECIFICATION FOR UNBONDED FLEXIBLE PIPE 53 pipe annulus has a sealed intermediate layer, as in some thermal insulated pipe designs, the design of the thermal insulation shall be based on the premise that the innermost annulus has reached steady-state intact annulus conditions. Bulkheads or additional polymer sheaths may be used to limit the volume of the pipe structure to be flooded. The design methodology, including outer sheath damage assumptions, shall be documented. End cap effects on sealed insulation shall be calculated and used in design. Conditions experienced during storage, transportation, handling, installation, and operation shall be analyzed and, where necessary, performance demonstrated by installation simulation tests. The manufacturer shall verify and document that permanent deformation of the insulation layers, resulting from crushing caused by items including tensioners, reels, sheaves, rollers, self-weight, and impact loads, does not change the heat transfer coefficient or cooldown time, as required, beyond the specified requirements. 5.4.4 Gas Venting The gas-venting system shall be designed to the requirements of 4.6.1.5 and the following: a) safe removal of permeated fluids; b) no uncontrolled pressure buildup outside the pipe if the pipe is located within an enclosed space; c) chemical resistance of all parts exposed to the permeated fluid and seawater. The following design requirements shall apply to the gas-venting system: a) it shall be documented that the valve will open before the outer sheath bursts, when the sheath wall thickness is at the minimum tolerance; b) the maximum vent system pressure in the annulus shall not collapse or blister the internal pressure sheath during depressurization of the bore or annulus; c) burst disks should only be used as a backup venting system; d) gas-relief valves used as part of a venting system for a subsea pipe shall not allow ingress of seawater accounting for the maximum hydrostatic pressure; e) there shall be minimum two vent ports coming out of the end fitting for flowlines and three vent ports for risers; f) if gas-relief valves are used, two valves per end fitting shall be required as a minimum; g) the valve design shall account for the specified marine growth conditions; h) no possibility of return of gasses or fluids from outside the flexible pipe into the flexible pipe annulus shall exist. The gas drainage shall be through the end fitting of the pipe unless otherwise specified in 4.6.1.5. The design of all layers in the pipe shall allow for permeated gas to be vented. The venting system shall be qualified, certified, and tested to comply with the required operational parameters and avoid blockage by annulus byproducts. 5.4.5 Pigging and TFL Operations The flexible pipe shall be designed for the pigging, TFL, workover, and other tool requirements specified in 4.6.1.6. The selection of dimensional tolerances, including ovality, shall account for the specified requirements. See API 17C for guidelines on TFL systems. 54 API SPECIFICATION 17J The innermost layer (carcass insert, carcass, or internal pressure sheath) selected for the pipe design shall be compatible with the specified requirements, and the manufacturer shall have performed documented tests to demonstrate compatibility. The pipe design should result in a smooth interface between the innermost layer and the end fitting. Any variation in wall thickness caused by corrosion shall not influence pigging operations. End fitting designs shall be such that a variation in wall thickness as a result of corrosion shall not result in damage to the internal carcass or internal pressure sheath during pigging operations. 5.4.6 Fire Resistance If fire resistance is required in accordance with 4.6.1.7, the pipe shall be designed and tested in accordance with the requirements of API 17L1 and API 17L2. 5.4.7 Routing Pipe crossing on the seabed shall be acceptable as long as appropriate protection measures are taken. These can include the following: a) separating the pipes with a mattress, b) entrenching one of the pipes, c) demonstrating with calculations that the pipes can withstand the crossing loads and the outer sheaths can withstand any abrasive damage. 5.4.8 On-bottom Stability On-bottom stability analysis shall demonstrate that under extreme functional and environmental loading conditions, pipe movements do not exceed limits specified by the purchaser. The functional and environmental loading conditions shall account for the following as a minimum: a) internal pressure; b) internal fluid temperature; c) water depth and wave loading if applicable at pipe depth; d) current loading at pipe depth; e) seabed characteristics. If the purchaser does not establish limits, then the manufacturer shall submit a criterion. NOTE See DNV-RP-F109 for guidance on on-bottom stability analysis. 5.4.9 Installation Requirements Manufacturer shall verify and document as a minimum that crushing loads resulting from contacts of the flexible pipe against tensioners, reels, sheaves, rollers, self-weight, maximum tension do not generate unacceptable deformation of the flexible pipe products. The minimum squeezing load to avoid slippage shall be validated by testing. Manufacturer shall provide the coefficients of friction that will be considered for installation sequence. Those coefficients of friction shall be clearly documented including all impacts related to: SPECIFICATION FOR UNBONDED FLEXIBLE PIPE 55 a) the nature of the interface and the materials, b) temperature, c) contact pressure distribution from the installation pads when applicable, d) presence of water. The manufacturer shall evaluate the tribological behavior between adjacent layers from the outermost tensile armor layer and above. The design methodology shall account for the friction factors between adjacent layers, and specific design criteria shall be determined to avoid flexible pipe slippage during installation/recovery and avoid damages made to the flexible pipes. The design methodology shall take into account the effects of the additives and lubricants used during manufacturing and the effects of aging and annulus flooding in the friction coefficients. 6 Materials 6.1 Material Requirements 6.1.1 General The requirements of Section 6 shall apply to polymer materials, including additives; flat, round, or shaped metal wire forms; the materials used for the anti-buckling layers; and finished or semifinished end fitting components, as delivered to the pipe manufacturer by suppliers and subject to manufacturing processes as employed by the manufacturer. Section 6 does not cover the use of composite materials for tensile armors, pressure armors, and carcass layers. The manufacturer shall have on file records of tests demonstrating that the materials selected for a specific application meet the functional requirements specified in Section 4 for the service life, for both operation and installation conditions. The documented test records shall conform to the requirements of 6.2. Where qualification records do not exist, the manufacturer shall conduct testing relevant to the application according to 6.2. All materials in contact with the internal fluids and injected chemicals, such as those used in carcass, internal seals, and internal pressure sheath, shall be selected to be compatible with the fluid composition, temperature range, and design pressure specified in the functional requirements for all service life phases. All materials, including antiwear layers, tapes, lubricants, and other manufacturing aids used in the flexible pipe construction, shall be compatible with seawater and permeated gases and liquids at design temperatures. Compatibility can be limited to determination that decomposition of these materials does not create byproducts harmful to functional layers (such as the internal pressure sheath or metallic armors) of the pipe. The manufacturer shall ensure that all lubricants and corrosion protection coating used in the manufacture of the pipe are compatible with all other structural or pressure-sealing materials in the pipe. The manufacturer shall utilize documented test procedures to determine the material properties specified in Table 13, Table 14, and Table 15. 6.1.2 6.1.2.1 Polymer Materials General The material properties specified in Table 13 shall be used to define the prequalified range and combination of exposure and temperature conditions for each of the polymers used in the internal pressure sheath, antiwear layer/tape, intermediate sheath, outer sheath, and insulation layer. 56 6.1.2.2 API SPECIFICATION 17J Internal Pressure Sheath The material properties for the internal pressure sheath, as specified in Table 13, shall be determined for a range of temperatures and pressures that shall include the design values. For some cases, the design absolute pressure may need to be used instead of the design differential pressure. The manufacturer shall have validated methods for predicting the polymer properties for the specified service life. The manufacturer shall have available for review by the purchaser records of tests and evaluations that demonstrate that the methods yield conservative results. If the conveyed fluid contains gas, the polymer shall be shown, by testing, not to blister or degrade during rapid depressurization from the maximum design or incidental pressure and temperature conditions. The effect of aging and swelling on permeability shall be analyzed. The manufacturer shall specify the criteria to be applied to the polymer for assessment of serviceability and quantify its application, using results of testing consistent with the requirements of 6.1.2.2. The assessment of serviceability and associated testing shall evaluate the effects of embrittlement, creep, stress relaxation, shrinkage, swelling, residual and/or plastic deformation, and other degradation modes and mechanisms that may impact the internal pressure sheath functionality. Pressure, temperature, and fluid exposure may lead to increased swelling of polymeric materials into the gaps of the adjacent layers. The assessment of serviceability shall include verification of the effects of the creep into gaps in the overall pipe behavior and on the polymer considering the maximum and minimum design values. Stress concentration, cyclic effects, and interlayer movement shall not lead to failure or cracks in the polymeric sheaths. 6.1.2.3 Intermediate Sheath The material properties for the outer sheath, as specified in Table 13, shall be determined for a range of temperatures and annulus pressures that shall include the design values. The material properties for the intermediate sheath, as specified in Table 13, shall be determined for a range of temperatures and pressures that shall include the design values. 6.1.2.4 Outer Sheath The manufacturer shall confirm compatibility of the outer sheath with all permeated fluids, ancillary components, and all external environmental conditions specified in 4.5. 6.1.2.5 Insulation Layer The thermal conductivity of the layer shall be determined for both dry condition and seawater-flooded condition and for the design and operating temperatures and pressures taking into account the long-term effect of aging and water absorption on thermal properties. The manufacturer shall verify with tests that the compressive strength of the insulation material is sufficient to withstand all expected compressive loads within the design requirements of 5.4.3. Flooding of the annulus shall not affect this requirement. SPECIFICATION FOR UNBONDED FLEXIBLE PIPE 57 Table 13—Property Requirements for Polymer Materials Parameter (1) Internal Pressure Sheath Intermediate Sheath Antiwear Layer Outer Sheath (5) Insulation Layer (2) Resistance to creep X (3) X X (4) X X Tensile properties (6) X X M X M Stress relaxation properties C C — C — Modulus of elasticity X X — X — Compression properties X X — X X Hydrostatic pressure resistance — — — — X Wear resistance — — X (4) C — Density X X X X X Fatigue (7) X C — C — Notch impact test C — — C — Coefficient of thermal conductivity X X X X X Coefficient of thermal expansion X X — X — Heat capacity X X X X X Brittleness or glass transition temperature C C — C — Fluid permeability X X — X — Blistering resistance X — — — — Fluid compatibility X X X X X Aging tests X X X X X (8) Environmental stress Compatibility and aging cracking C C C C — Ultraviolet weathering resistance — — — X — Water absorption — — — — X Characteristic Mechanical/physical properties Thermal properties Permeation characteristics NOTE 1 Test procedures are specified in Table 16. There are no property requirements for manufacturing aid materials. NOTE 2 The property requirements specified for the insulation layer apply to the use of both polymers and nonpolymers. NOTE 3 X (required for design), C (comparative, cannot be used directly for design), M (not required for design, for manufacturer’s analysis only). NOTE 4 The requirements for polymer material properties specified above shall apply both to dry and wet annulus conditions (i.e. seawater flooded and flooded by condensed water), unless it can be justified that it has no impact on the given property. NOTE 5 On top of the outer sheath may be an additional protective layer. NOTE 6 As a minimum, stress at yield, strain at yield, stress at break, and strain at break shall be determined. NOTE 7 Applicable for dynamic applications only. NOTE 8 If polyvinyl chloride (PVC) is used as the insulation material, a heat stability test shall be performed at or above the maximum design temperature for a period of at least 30 days. 58 6.1.2.6 API SPECIFICATION 17J Antiwear Layers The material properties for the antiwear layer, as specified in Table 13, shall be determined for a range of temperatures and contact pressure that shall cover the design values. For dynamic applications, the manufacturer shall provide evidence of documented tests or from field experience that the antiwear layer performs its function, preventing wear between adjacent steel layers for the specified service life. 6.1.3 6.1.3.1 Metallic Materials General For the specified application, the manufacturer shall, for each of the characteristics listed in Table 14, confirm by testing the suitability of the selected material and weldments, if applicable. Material selection shall consider corrosive attack appropriate to the environment to which the layer is exposed over the specified service life of the pipe. Materials for sour service applications shall be tested in accordance with 6.2.4.2. All metallic components designed for, or that can be exposed to, cathodic protection shall be made of materials that are resistant to hydrogen embrittlement in the applicable environment. Table 14—Property Requirements for Metallic Wire and Strip Materials and Weldments Carcass (5) Pressure Armor Tensile Armor Chemical composition X (2) X X Microstructure C C C Tensile properties (yield strength/ultimate tensile strength) X X X Elongation C C C Hardness C C C Fatigue resistance X X X Erosion resistance X — — Stress corrosion cracking (SCC) — X X Sulfide stress cracking (SSC) and hydrogen-induced cracking (HIC) resistance — X X Corrosion resistance (fluids, chemicals) X (3) X (6) X (6) Cracking resistance under cathodic protection — — X Properties/Characteristics Alloy properties Mechanical properties (4) Material characteristics (4) Parameter (1) NOTE 1 Test procedures are specified in Table 17. NOTE 2 X (required for design), C (comparative, cannot be used directly for design), M (manufacturer’s analysis). NOTE 3 Check for SSC, SCC in corrosion resistance test. NOTE 4 Properties to be determined on wire specimen with plastic strain and residual stress levels representative of wires retrieved from as manufactured pipes, taking into account representative stress relief occurring during factory acceptance test, offshore leak test, or any other event in operation. NOTE 5 Same for carcass insert if applicable. Carcass corrosion resistance tests shall consider the design pressure. NOTE 6 Always check for any crack (SSC, HIC, SCC) and corrosion pit in all corrosion resistance tests. SPECIFICATION FOR UNBONDED FLEXIBLE PIPE 6.1.3.2 59 Carcass If the carcass and/or carcass insert are to be exposed to tools passing through the pipe, including pigs, TFL, and workover equipment, the wear rate from all expected occurrences shall be calculated or experimentally determined. Additional sacrificial material shall be included in pipes that are expected to experience high wear or abrasion rates (due to erosion or abrasion). The amount of additional material shall be determined by analysis using wear-rate data and expected occurrence rates. The material selection for the carcass and carcass insert shall account for the installation conditions, in particular if the pipe is to be temporarily filled with seawater or undergo wet storage. The properties of duplex stainless steels shall be documented according to the requirements detailed in a relevant material data sheet (MDS) as per IOGP S-563 or ISO 13703-2. If a relevant MDS is not available, manufacturer shall present a MDS to be agreed with the company. The corrosion effects from depassivation and passivation associated with tools or fluids passing through the pipe shall also be evaluated by the manufacturer based on information given by the operator regarding those specific operations. 6.1.3.3 Pressure and Tensile Armors For the specified application, the manufacturer shall determine the sensitivity to corrosion (uniform and pitting) and cracking (SCC, SSC and HIC) occurring in the carbon steel materials selected for the pressure and tensile armors. SCC, SSC, and HIC corrosion sensitivity shall account for local stresses and local strain history in the armor wires, taking into account representative stress relief occurring during factory acceptance test (FAT), OLT, or any other event in operation. 6.1.4 6.1.4.1 End Fitting Metallic Materials End fitting metallic primary components shall be wrought or forged or made by additive manufacturing in accordance with the requirements of ASTM A668/A668M, ASTM A29/A29M, ASTM A694, ASTM A182/A182M, DNV-ST-B203, DNV-RP-0034, or API 20S (for additive manufacturing) if required by purchaser. For sour service applications, metallic materials shall be in accordance with ANSI/NACE MR0175/ISO 15156 requirements. The manufacturer shall document the chemical composition, manufacturing method, heat treatment, and the tensile, hardness, and Charpy impact properties for the metallic materials in all primary end fitting components. The chemical composition should be selected to ensure that the components meet the property requirements for the specified service after all manufacturing processes, including welding and weld heat treatments. The end fitting inclusive of vents, where applicable, shall be resistant to corrosion, either by way of material selection or by means of the combination of a suitable coating and cathodic protection. The material for the end fitting internal surfaces shall be resistant to erosion due to solids entrained in the conveyed fluid. All metallic components designed for, or that can be exposed to, cathodic protection shall be made of materials that are resistant to hydrogen embrittlement in the applicable environment. All materials and surfaces exposed to the conveyed fluid or annulus environment shall be verified by tests to be corrosion resistant. Material selection for end fitting components shall avoid galvanic corrosion between components through material or coating selection. Sheath seal rings and flange sealing surfaces shall be corrosion resistant through material or coating selection. The end fitting coating should be documented to be resistant against external abrasion for end fittings on the seabed, and impact from installation/handling as specified by the purchaser, or alternatively external end fitting protection should be provided. 60 6.1.4.2 API SPECIFICATION 17J Epoxy Material The epoxy filler material used to embed the tensile armors shall be documented to withstand the temperatures experienced by the end fitting during manufacture and service for the specified service life. Consideration shall be given to the maximum temperatures that can be experienced by the end fitting in enclosed spaces, such as underneath fire insulation and bend stiffeners, or when buried into the seabed. The manufacturer shall document the compressive strength of the epoxy at a temperature between 20 °C and 25 °C and at design minimum and maximum temperatures. Glass-transition temperature, fluid compatibility, and aging characteristics of the epoxy shall be documented. The epoxy used in testing shall be mixed and cured according to the epoxy suppliers’ specifications. 6.1.4.3 Polymeric Materials The polymeric materials that are part of the end fitting sealing and anchoring systems shall be documented to withstand their pressure, temperature, and environment that they are exposed to throughout the service life. The manufacturer shall confirm the suitability of the selected materials through testing in accordance with ISO 23936-1 for thermoplastic compounds or according to ISO 23936-2 for rubber grades. If the conveyed fluid contains gas, the polymeric materials in the end fitting, if applicable, shall be shown, by testing, not to blister or degrade during rapid gas depressurization from the maximum design pressure and temperature conditions. The manufacturer shall specify the criteria to be applied to the polymer for assessment of serviceability and quantify its application using results of testing consistent with the requirements of 6.1.2 and Table 13. 6.1.5 Anti-buckling Layers The manufacturer shall document the properties of the material for the anti-buckling layers, as specified in Table 15, for a range of temperatures that shall include the design values. The aging tests shall be documented for both dry, intact annulus and annulus flooded with deaerated seawater conditions and for the operating temperatures. Degradation of strength performance over the specified service life, resulting from temperature (including thermal effect due to unintended insulation, e.g. burial, marine growth, and bend stiffeners), annulus environment, and seawater, where applicable, shall be accounted for in flexible pipe design. The fatigue performance of the anti-buckling layers shall be taken into account in design of the dynamic riser applications. As thermal properties of this layer are of secondary importance to the overall thermal performance of the pipe, the thermal conductivity and heat capacity of this layer can be determined either by testing or estimated by calculation from raw material data. SPECIFICATION FOR UNBONDED FLEXIBLE PIPE 61 Table 15—Property Requirements for Anti-buckling Tapes Properties/Characteristic Mechanical/physical properties Thermal properties Permeation characteristics Compatibility and aging 6.2 Parameter Anti-buckling Tape Resistance to creep C (1) Yield strength/elongation X Ultimate strength/elongation X Stress relaxation properties — Modulus of elasticity X Hardness — Compression strength — Hydrostatic pressure resistance — Impact strength — Abrasion resistance X Density X Fatigue C Notch sensitivity — Coefficient of thermal conductivity C Coefficient of thermal expansion — Softening point — Heat capacity C Brittleness (or glass transition) temperature — Fluid permeability — Blistering resistance — Fluid compatibility X Aging tests X Environmental stress cracking (2) X Weathering resistance — Water absorption — NOTE 1 X (required for design), C (comparative, cannot be used directly for design), M (manufacturer’s analysis). NOTE 2 If the material is susceptible to the failure mechanism. Testing Requirements 6.2.1 6.2.1.1 General Test Requirements The physical, mechanical, chemical, and performance characteristics of all materials in the flexible pipe, as specified in Table 13, Table 14, and Table 15, shall be verified by the manufacturer through a documented test program. The program shall confirm the adequacy of each material based on test results and analysis that shall demonstrate the suitability of the material for the specified service life of the flexible pipe. 62 API SPECIFICATION 17J Test procedures listed in Table 16 and Table 17 shall be used to determine the properties specified in Table 13, Table 14, and Table 15. If the test method is not specified in Section 6, guidance may be obtained from API 17A or the manufacturer may use their own methods, subject to the requirements of 6.2.1.4. The qualification of materials by testing shall consider all processes (and their variation) adopted to produce the pipe that can impair the properties and characteristics required by the design. If qualification tests cannot be carried out on processed materials, the manufacturer shall justify in the documented qualification program why the selected material provides equivalent characterization as the processed material. Use of non-processed materials shall be subject to IVA or purchaser approval. 6.2.1.2 Test Data Test data shall be kept on file for 20 years after delivery to the purchaser or for the service life, whichever is greater. 6.2.1.3 Applicability Only materials with identical specified chemistry and material manufacturing process (e.g. heat treatment, cold forming, etc.), as used in the qualification testing, shall be regarded as qualified. If the manufacturer demonstrates the behavior similarity for an identical specified chemistry and material manufacturing process but with different geometry/sizes, the qualification testing could be extended to qualify other geometry/sizes by similarity (as agreed with the IVA). Documented operational experience may be accepted as verification of long-term properties in environments that are equal to or less severe than the documented experience. The severity of the environment for metallic components shall be determined by temperatures, stresses, strains, contact pressures, corrosive environments, pH, chloride content, injected chemicals, concentrations (partial pressure, fugacity) of H2S and CO2, and other conditions deemed by the manufacturer or purchaser to be detrimental. The environmental factors considered for polymers shall include temperatures, strains, pressures, concentrations of water, aromatics, alcohols, H2S and CO2, UV exposure, acidic conditions (lower pH or higher TAN), and other conditions deemed by the manufacturer or purchaser to be detrimental. 6.2.1.4 Test Methods The test methods shall be as specified in 6.2. Where test methods are not specified, the manufacturer may use their own methods and/or criteria or alternative methods developed by the raw materials supplier. In such cases, the methods and/or criteria shall be documented, and the results correlated with the specific material application. Where test methods are specified but alternative methods are followed, the manufacturer shall justify in the documented qualification program why the alternative methods used provides equivalent or better characterization than the specified test methods. Nonstandard test methods shall be verified by an IVA or approved by the purchaser. NOTE Use of equivalent ISO or ASTM standard test procedures does not require justification. 6.2.2 Polymer Materials 6.2.2.1 General Test procedures listed in Table 16 shall be used to determine the properties specified in Table 13 and Table 15. SPECIFICATION FOR UNBONDED FLEXIBLE PIPE 6.2.2.2 63 Samples Used for Qualification Testing Samples used for qualification testing of polymer sheath, insulation, and antiwear materials shall be taken from extruded samples. For thermoplastic materials, molded specimens are not acceptable. If permanent features, such as whitening or plastic deformation, are allowed throughout the pipe service life, handling, or installation, the samples used for qualification testing shall also include these features. 6.2.3 6.2.3.1 Polymer Test Procedures General This section describes tests procedures to be used when no ISO or ASTM standard test procedure is given in Table 16. 6.2.3.2 Fluid Permeability For fluid permeability tests, the following conditions shall apply as a minimum. a) Sample: Sample shall be taken from an extruded material. b) Thickness: Minimum is 1 mm (0.04 in.) (see Note). c) Diameter: Minimum is 40 mm (1.57 in.) effective diameter (see Note). d) Temperature: Data required over the design range of the polymer, with sufficient tests to allow interpolation. e) Pressure: Data required over the design range of the polymer (both sides of sample sheath whenever relevant), with sufficient tests to allow interpolation, unless permeability can be demonstrated to be independent of pressure. f) Repeatability: A number of tests shall be carried out to ensure repeatability. ISO 2556 requires a minimum of three samples for each measurement. NOTE The test may be carried out using a disc sample with other dimensions provided the ratio diameter over thickness is greater than 20. Alternatively, an extruded tube may be used if its crystallinity values are proven to be similar to extruded material for regular pipe production and thickness is at least 1 mm. The procedure for the fluid permeability test should typically pressurize one side of the specimen and measure fluid flow at the other side when steady-state flow conditions are reached. Tests should characterize the transport of individual permeating species. Diffusion, solubility, and permeation coefficients should be derived. As described in API 17B, these values shall be used in determining the annulus environment for use in-service life evaluation of the armor wires, as required by 5.3.4. 64 API SPECIFICATION 17J Table 16—Test Procedures for Extruded Polymer (Including Antiwear Layers and Insulation) and Anti-buckling Layer Materials Property/ Characteristic Parameter ASTM D2990 Tensile properties and modulus of elasticity ISO 527-1 ISO 527-2 ISO 527-3 ASTM D638 ASTM D882 ASTM D3759 (4) ISO 3384-1 ASTM E328 ISO 604 ASTM D695 Hydrostatic pressure resistance — — Abrasion resistance ISO 9352 ASTM D4060 Density Fatigue Notch sensitivity Coefficient of thermal conductivity Coefficient of thermal expansion ISO 1183-1 6.2.3.7 ISO 179 (all parts) ASTM D792 Or ASTM D1044; this is only a qualitative test for comparison; guidance is given in API 17L1 Or ASTM D1505 ASTM D256 — ISO 8301 ASTM C518 ISO 11359-2 ASTM E831 — Heat capacity ISO 11357-1 ISO 11357-4 ASTM E1269 — Glass transition temperature ISO 11357-2 ASTM E2602 ASTM E1356 ASTM E1640 Method can be based upon differential scanning calorimeter or dynamic mechanical thermal analysis ISO 974 ASTM D746 Compression properties Permeation characteristics Compatibility and aging Due to temperature and pressure ISO 899-1 (5) Thermal properties Comments (2) Resistance to creep (5) Stress relaxation properties Mechanical/ physical properties Test Procedure (1) (3) ISO or Section ASTM (2) Number (2) Brittleness temperature — — Sample specimens may represent actual layer geometry (sheath/tape) Guidance is given in API 17L2 Or ISO 8302/ASTM C177 — As a minimum to CH4, CO2, H2S, methanol, and H2O where present; ISO 2556 may be considered as an alternative — — — Manufacturer to specify test method; this is only a qualitative test Fluid permeability 6.2.3.2 — Blistering resistance Fluid compatibility Aging tests 6.2.3.3 6.2.3.4 6.2.3.5 — — — UV resistance ISO 4892-2 — Water absorption 6.2.3.6 — Guidance can be found in ISO 62/ASTM D570 ISO 22088-3 ASTM D1693 — Environmental stress cracking NOTE 1 The test procedures apply to the property requirements specified in Table 13 and Table 15. NOTE 2 For the purposes of the requirements for the listed test, the ASTM reference(s) listed is/are equivalent to the associated ISO International Standard, where one is given. Example: For the purposes of the procedure for the resistance-to-creep test, ASTM D2990 is the equivalent of ISO 899-1. NOTE 3 Where test methods are not specified, the manufacturer may use their own methods as per the requirements of 6.2.1.4. NOTE 4 ASTM D3759 is for films and tapes less than 1 mm thick. NOTE 5 Creep and stress relaxation tests shall adopt parameters (e.g. loads, temperature) that cover the pipe handling, storage, installation, test, and operation. SPECIFICATION FOR UNBONDED FLEXIBLE PIPE 6.2.3.3 65 Blistering Resistance Blistering resistance tests shall reflect the design in-service requirements, relating in particular to fluid composition, pressure, temperature, number of depressurizations, and depressurization rate. Guidance can be found in API 17TR1 for consideration of shielded and constrained test samples. The following conditions shall apply as a minimum. a) Samples: Samples shall be taken from an extruded polymer sheath considering SOL and EOL conditions. b) Fluid mixtures: Use gas fluid components of specified environment as documented in the test procedure. c) Soak time: Use sufficient to ensure > 95 % saturation, as calculated from diffusion coefficients of fluids in the polymer. d) Test cycles: Use expected number of depressurizations in service, or 20 cycles as a minimum. e) Depressurization rate: Use expected depressurization rate in service or a minimum 70 bar/min. A lower depressurization rate is acceptable for pressure values below 10 % of the starting pressure. f) Thickness: Nominal manufactured or as a minimum 6 mm internal pressure sheath wall thickness. g) Temperature: Use the operating temperature as a minimum. h) Pressure: Use maximum operating pressure as a minimum. i) Procedure: After the last depressurization cycle (as a minimum), samples shall be examined at a magnification of 20× for signs of blistering and slitting. The acceptance criterion shall be that no blistering or slitting is observed. The manufacturer shall define acceptance criteria for swelling of the samples considering material and pipe behavior. 6.2.3.4 Fluid Compatibility The manufacturer shall evaluate all constituents of the environment to which the polymer is exposed and perform tests on those components that are considered to possibly have adverse effects on the polymer. The criteria for acceptance shall be verified by an IVA. Fluid compatibility tests shall be performed to the manufacturers’ or material suppliers’ documented procedures. These laboratory tests may be used to determine gross incompatibility. These tests shall be based on the design temperature, pressure, and strain. As a minimum, tensile strength, elongation at break, visual appearance, weight, and volume change shall be measured/evaluated. API 17B contains recommendations on test procedures. 6.2.3.5 Aging Tests The manufacturer shall have verified aging models for each polymer in the flexible pipe, unless it is demonstrated not to be applicable. The models shall be based on laboratory testing and field experience, if available. These models shall predict the deterioration of the polymer under the influence of relevant environmental and load conditions. The aging models may include accumulated damage concepts based on blocks of time or operational cycles of temperature/pressure under different exposure conditions. Aging may be determined by change in either specified mechanical properties or in specified physico-chemical characteristics, which includes reduction in the plasticizer content of the material and uptake of constituents from the fluid environment. Aging tests and models shall consider all conditions and combination of conditions that may be relevant for the long-term performance of the polymer for the defined operation. Relevant conditions will be fluid 66 API SPECIFICATION 17J composition, temperature, pressure, treatment chemicals (including dissolved oxygen), and oxygen. In addition to chemical degradation, the aging tests and models should also, depending on the type of material, address other effects such as deplasticization and extraction of leachables, fluid absorption, cross-linking, and dimensional stability. Mechanical loads and possible confinement should be taken into consideration where relevant. Transient conditions such as cooldown from gas expansion or treatment resulting in transient heating should be considered where relevant. Polymer materials shall be exposed to full saturation with the relevant conditions before they are aged. Full saturation shall be demonstrated before the aging period starts. Adjustments to the environment to accelerate testing shall be subject to verification of its effects in the material. For anti-buckling layer materials, the assessment of aging shall include the effect of temperature and annulus environment. The fluid used in aging-resistance tests should be representative of the specified internal fluid. Materials that are tensile- or compressive-loaded in service should be tested with similar stresses induced. 6.2.3.6 Water Absorption Test A water absorption test shall allow for long-term prediction of thermal insulation layer conductivity variation. A relationship should be established for weight gain vs time and for thermal conductivity vs weight gain to allow for extrapolation. 6.2.3.7 Fatigue Test of Internal Pressure Sheath The manufacturer shall have verified fatigue models for the internal pressure sheath. The models may be based on laboratory testing, full-scale testing, and field experience. These models shall be used to document a sufficient service life. Polymer fatigue tests shall account for the effects of the internal pressure sheath geometry (Kt value), temperature, and aging. Test specimens shall be loaded in displacement control (axial or bending mode) and use representative conditions. 6.2.4 6.2.4.1 Metallic Materials General At a minimum, the qualification test program for carcass, pressure armor, and tensile armor layer materials shall include the tests specified in Table 17. 6.2.4.2 SSC and HIC Testing For sour service static applications, the threshold limits of the steel wire material to HIC and SSC shall be determined according to manufacturers’ documented criteria. To determine the resistance of the steel wires to HIC and SSC, the wires shall be subjected to the ANSI/NACE TM0177, NACE TM0284, and NACE TM0316 tests. The threshold level for the occurrence of SSC and HIC shall be determined by testing multiple specimens to various levels of H2S and pH. Tensile load or four-point bending or C-ring tests shall be used. Specimens shall be loaded to at least 90 % of the structural capacity and account for the strain history of pipe manufacturing. Sample stress during the test should be representative of the wire on the product (plastic and elastic stresses from manufacturing and also the in-service stresses). If average wire stress is calculated to exceed 90 % of the structural capacity under permanent extreme or abnormal operating conditions, then the wires shall be qualified for that stress level. SPECIFICATION FOR UNBONDED FLEXIBLE PIPE 67 Table 17—Test Procedures for Metallic Materials (Carcass Strip, Carcass Insert, Pressure Armor, and Tensile Armor Wires) and Weldments Parameter Chemical composition Test Procedure Comments ASTM A751/ISO 16120-1/ISO 16120-4 (for steel wires) (3) Tensile properties ISO 6892-1 Yield strength/ultimate tensile strength/elongation Hardness ISO 6507-1 Sour service applications only (armor wires only) Sulfide stress cracking (SSC) and hydrogen-induced cracking (HIC) 6.2.4.2 To specified environments (armor wires materials) Stress corrosion cracking (SCC) 6.2.4.3 To specified environments (armor wires materials) Corrosion resistance (fluids, chemicals) (1) (2) 6.2.4.4 To specified environments Erosion resistance 6.2.4.5 Carcass and/or carcass insert only Fatigue resistance 6.2.4.6 Pressure and tensile armors in dynamic applications only Hydrogen embrittlement 6.2.4.7 Only tensile armor wires where applicable and when exposed to cathodic protection NOTE 1 Consider checking for SSC and SCC during corrosion tests for carcass materials. NOTE 2 Corrosion tests shall be carried out on the formed material. NOTE 3 Manufacturer will have the possibility to adjust some ranges as long as it is documented in either their procurement specification OR their qualification dossiers. The manufacturer shall demonstrate through analysis or testing (duration 720 h) the SSC performance at the actual service conditions of the steel wire material. The actual service conditions comprise the calculated annulus partial pressure of H2S and the calculated pH in the annulus, in aqueous solution (3 % NaCl minimum) at ambient pressure and temperature. Specimens shall be loaded to at least 90 % of the structural capacity. Ninety (90) days extended test duration (as per NACE TM 0284 when H2S fugacity is lower than 3 mbar) for HIC assessment are required for qualification testing only and not for batch testing. The CH4 may be replaced with another inert gas. Production welds shall be included in steel wires to be validated for sour service applications. Following an SSC test, the steel wire material susceptibility to HIC shall be checked. Typically, three samples per wire batch should be tested unless otherwise agreed with IVA. Considering the H2S consumption methodology is used together with a certified diffusion model, then a safety factor of 1.5 on H2S level or 0.5 unit on pH shall be considered on the calculated project conditions. In case H2S consumption methodology is not used then no safety factor is needed, as long as the diffusion model is certified by an IVA. 6.2.4.3 Stress Corrosion Cracking (SCC) The materials grades of pressure and tensile armors shall be tested during qualification phase; this shall include different suppliers, cover wire sizes range (taken from a fully processed wire spool), and welds. Test duration after steady-state conditions are achieved shall be 6 months minimum to declare a specimen to pass. Test samples shall have seen maximum and cumulated strain representative of manufacturing process. 68 API SPECIFICATION 17J Prior to final loading, residual stresses shall be either removed by sufficient strain elongation or taken into account with a documented and validated process. For samples with notch, the pre-straining operation must be done before machining the notch on the sample. Samples shall be representative of the wire on the product (plastic and elastic stresses from manufacturing and also the in-service stresses) and shall be loaded to 100 % of their actual yield strength. Samples may be loaded to lower stresses if the manufacturer has validated models to demonstrate that the test condition is representative of the wire on the product. The number of samples per test should start with at least six. If the test method is statistically validated, or if there is sufficient data obtained from full-scale tests, the manufacturer may reduce the number of samples to three and submit the results and the improved test method for IVA review. No SCC cracks shall be observed on any of the samples to get a positive (no SCC) test result (no retest allowed). The sample can be loaded by bending or tensile loading conditions. Load levels shall be verified by strain gauges. For displacement-controlled type of loading, it shall be verified at the end of the test, when practically feasible, that no stress relaxation took place in the sample during the test execution. The test conditions shall cover the maximum calculated annulus fugacity of CO2 in the service life of the pipe at the worst location. If the manufacturer does not have a verified model for calculating annulus conditions, including the potential heterogeneity in the annulus, then pipe bore fugacities shall be used. Temperature effect (see Note) shall be taken into account to define the appropriate test environment for a specific material grade. The sample shall be tested in a solution made of synthetic seawater as per ASTM D1141, in a confinement representative of a flexible pipe annulus. If the sample is half immersed, the maximum local stress location shall be close to the waterline. After the test, 100 % of the samples shall be inspected by magnetic particle inspection (MPI) using a qualified procedure and all indications shall be cut for binocular inspection to determine if it is due to SCC or not. Proper safety factor, on both CO2 level and stress, shall be agreed between flexible pipe manufacturer and IVA, based on test evidence, in order to establish safe SCC-free domains. The SCC laboratory test method combined with the annulus environment prediction methodology shall be validated against medium-scale or full-scale corrosion tests with gas diffusing through the internal pressure sheath. NOTE Test in different temperature levels—within the range of in-service annulus temperature—may be necessary in order to determine the test temperature for which a specific steel grade is more susceptible to SCC. 6.2.4.4 Corrosion Resistance Armor wires shall be subjected to the following testing and evaluation, or equivalent documentation provided, and documented in the design report (8.4): a) exposure to aerated seawater (minimum 3 % NaCl), without protective cathodic potential in order to determine corrosion rate, cracking, and localized corrosion; b) exposure to the predicted annulus environment based on equivalent partial pressures of the transported fluids. SPECIFICATION FOR UNBONDED FLEXIBLE PIPE 69 For armor wires, the purpose of the test is to determine corrosion rate and susceptibility to localized corrosion. For localized corrosion assessment, the effect of local stresses and accumulated strain, corresponding to the pipe history, including manufacturing, FATs, storage, installation, OLT, and operation shall be considered. Carcass formed materials shall be tested to specified environments covering installation, storage (and wet storage, if applicable), and operation to determine the range of applications. The purpose of the test is to determine corrosion rate, cracking, and localized corrosion. Samples should have residual stresses representative of as manufactured pipe. Test set up shall account for stresses representative of the residual stresses from manufactured pipe and operational loads. Corrosion resistance tests may be carried out with a polymer over layer on the sample to simulate the multilayer construction characteristics. 6.2.4.5 Erosion Resistance The manufacturer shall demonstrate, either with tests or analytical data based on tests, that the innermost layer has sufficient erosion resistance to meet the design requirements for the specified service life; see API 17B for recommendations on erosion tests. 6.2.4.6 Fatigue Resistance For dynamic applications, steel wires shall be subjected to the fatigue testing and evaluation or equivalent documentation provided. See API 17B for recommendations on fatigue testing methodology. Specimens shall retain as-manufactured surface and only be degreased. The effect of manufacturing process including end fitting mounting shall be documented. When welds in the fatigue-critical areas (e.g. the bend stiffener area) cannot be avoided, then the effect of welding in pressure and tensile layer wires shall be verified in S-N curves, by either a S-N curve made entirely with welded samples or by comparing the fatigue resistance of some welded samples vs parent material. S-N data shall be documented, justified, or generated for the following testing environments: a) exposed to air, at atmospheric pressure and ambient temperature; b) exposed to deaerated seawater (minimum 3 % NaCl), inclusive of H2S and CO2 levels for relevant transported fluids (this environment is conservatively covering the intact annulus case in presence of condensed water; however, this environment with condensed water can be used in specific case in agreement with the purchaser); c) consideration should be given to the effects of cathodic protection systems on S-N performance. NOTE Refer to ASTM E739 (latest revision) for recommendations on the number of samples and statistical analysis to be used to generate S-N data. The design curve shall be based on minimum 12 failures. Failure criteria is defined in DNV RP-F204, Appendix B. 6.2.4.7 Hydrogen Embrittlement The tensile armor wires shall be tested to confirm that the potential hydrogen evolution resulting from cathodic charging does not result in hydrogen embrittlement. The testing shall be conducted on degreased wire samples immersed in aerated synthetic seawater that conforms to ASTM D1141, with a maximum negative cathodic potential applied per the manufacturer’s specification. NOTE The default value of the maximum negative potential is –1100 mV measured against the Ag/AgCl reference electrode. 70 API SPECIFICATION 17J The wire shall be stressed to its maximum utilization level expected in service. The cathodic charging shall be applied for a minimum duration of 150 h. Post-test examination shall be conducted, and the acceptance criterion shall be that no blistering or cracking of the wire sample has occurred. 6.2.5 6.2.5.1 End Fitting Metallic Materials Test samples used in the qualification of metallic materials for end fitting components shall be in accordance with the following. The qualification program shall test in accordance with the specified procedure and document the following properties and characteristics of the metallic materials for the primary end fitting components: a) chemical composition: ASTM A751; b) tensile properties: ISO 6892-1; c) Charpy impact: as described below; d) hardness: as described below; e) SSC and HIC resistance: 6.2.4.2; f) corrosion resistance (ASTM G48-03, Method A applies if duplex stainless steel end fittings are specified). The mechanical properties of forgings shall be determined from test samples that represent the actual component, including being from the same heat and heat treatment batch and having the same forging ratio. The location of test samples shall represent the heaviest thickness and shall be taken in 1/4t position from outer diameter (OD), where t is the thickness of the component. If end fitting components of different dimensions are in the same lot, it is sufficient to test the largest dimensions only, provided the strength requirement is the same in all dimensions. Charpy V-notch impact testing shall be carried out in accordance with ISO 148-1 for carbon or low-alloy steel forgings. Full-sized Charpy V-notch specimens in accordance with ISO 148-1 shall be used whenever possible. The notch shall be perpendicular to the surface. The test temperature shall be –20 °C (–4 °F) or the design minimum or incidental temperature if lower than –20 °C (–4 °F). Energy values shall be in accordance with the manufacturer’s specifications, which shall specify minimum single impact energy values and minimum average of three values, acceptable specimen sizes to be 10 mm by 10 mm (0.39 in. by 0.39 in.), 10 mm by 7.5 mm (0.39 in. by 0.30 in.), and 10 mm by 5 mm (0.39 in. by 0.20 in.). The hardness tests of carbon steel forgings and corrosion-resistant weld overlays shall be performed in accordance with ISO 6506-1, ISO 6508-1, or ISO 6507-1. The results shall be to manufacturers’ specifications, which shall distinguish between sour and sweet service applications. For sour service, hardness values shall be in accordance with ANSI/NACE MR0175/ISO 15156. 6.2.5.2 Epoxy Material Epoxy samples for testing shall be molded and cured under the same temperature and humidity conditions as when filling the end fitting. The qualification test requirements for the cured epoxy shall be as follows: a) compression strength: either ASTM D695 (compression) or ASTM D3410 (shear) based on manufacturer’s design methodology; b) shear strength; SPECIFICATION FOR UNBONDED FLEXIBLE PIPE 71 c) glass transition temperature: ASTM E1356; d) fluid compatibility: 6.2.3.4; e) aging test: 6.2.3.5; f) degree of cure: differential scanning calorimeter (DSC) to ASTM D5028. 6.2.5.3 Sealing Material Sealing materials exposed to hydrocarbon bore environments and/or annulus environment can be based on both rubber or thermoplastic. Samples for these environments shall be produced and tested according to ISO 23936-1 for thermoplastic compounds or according to ISO 23936-2 for rubber grades. 6.3 6.3.1 Quality Assurance Requirements General All base materials used in flexible pipe shall be purchased in accordance with either a written material specification or an industry standard. The specification shall include measurable physical, mechanical, chemical, and performance characteristics and tolerances. All suppliers to the manufacturer shall have a documented quality assurance system. As a minimum, base metallic materials shall be certified to ISO 10474:1991, Certificate 3.1 (EN 10204:2004, Section 4.1). Base materials shall be tested in accordance with the requirements specified in Table 18. Test results shall be recorded on material test certificates. Table 18—Minimum Raw Material Quality Control Test Requirements Material Polymers Metallic wires and strips Parameter Minimum Frequency Comments Viscosity One per batch (1) Sheath material (PA-12 and PA-11 only); ISO 307 (2) procedure. Extractables One per batch Applies to plasticized materials only. Impurities One per batch Sheath material (3) (with exception of pigmented plastics). Density One per batch Sheath material (polyethylene only); ASTM D1505 procedure. Melt flow index (MFI) (8) or One per batch melt volume rate (MVR) (8) Sheath material; ISO 1133-2/ASTM D1238 procedures. Chemical composition One per cast All wires and strips. Tensile test Two per coil (4) All wires and strips. Bend test Two per coil (4) (7) All wires and strips. Hardness test Two per coil (4) (7) All wires and strips. All wires: start and end of coil. Dimensions One per coil (4) All strips: start and end of coil used for sampling for the concerned mother coil (ASTM A480/A480M procedures for strip). 72 API SPECIFICATION 17J Material End fittings primary components Comments Sulfide stress cracking/hydrogen-induced Three per batch (6) cracking (9) Test on all wires and strips (excluding corrosion-resistant alloy strips) without welds, duration of 720 h of specimen exposition. Chemical composition One per heat (5) Structural body (or housing per API 17B, Figure 8 b) material. Tensile test Two per heat Structural body (or housing per API 17B, Figure 8 b) material. Charpy V-notch One set per heat Structural body (or housing per API 17B, Figure 8 b) material; subject to 6.2.5.1. Hardness test One per heat Structural body (or housing per API 17B, Figure 8 b) material; subject to 6.2.5.1. Radiography or phased array ultrasonic testing One Welded neck only. Ultrasonic One Structural body (or housing per API 17B, Figure 8 b) material. Magnetic particle or liquid penetrant One Carbon and low-alloy steel surfaces. Anti-buckling Tensile test layer Linear weight material Epoxy Minimum Frequency Parameter One per batch Compression test For fiber material only. — See 7.6.4. NOTE 1 Only a measurement of viscosity or MFI, but not both, is required. NOTE 2 For the purposes of this provision, ASTM D2857 is equivalent to ISO 307. NOTE 3 Pigmented plastics cannot be evaluated for impurities. NOTE 4 For wires: two per coil. For strips: two per mother coil. A coil is a continuous length of wire from the same forming process, cast, and heat treatment batch. Slitting of mother coils does not change mechanical properties, so slit strip does not require further mechanical testing after certification of the mother coil. If intermediate welds used to join coil sections for transport have been validated by the subcontractor in accordance with the manufacturer’s procedures, these welds may be kept during winding onto the pipe. If these welds have not been validated, they shall be cut out of the coil during the winding of the pipe. NOTE 5 Per heat refers to heat treatment batch. NOTE 6 Unless otherwise agreed with independent verification agent or purchaser. NOTE 7 Frequency can be reduced to one per batch if documented by the manufacturer. NOTE 8 Not applicable for polyamides because of high influence of water content on MFI or MVR result (e.g. for MVR see ISO 1133-2:2011, Table A.1, example for PA-6). NOTE 9 Test required only for sour service application. Test results shall conform to the manufacturers’ specifications. The results of all tests made by the manufacturer and/or suppliers shall be available for review by the purchaser. For the internal pressure sheath, polymers shall be 100 % virgin material containing no regrind or other previously processed materials. Requirements and criteria for surface condition of wires and shaped strips shall be established and documented by the manufacturer. As a minimum, the metallic materials shall have a surface finish free from defects that exceed the acceptance criteria set by the manufacturer and documented in the manufacturing quality plan or fabrication specification. SPECIFICATION FOR UNBONDED FLEXIBLE PIPE 6.3.2 73 Documentation Requirements The manufacturer’s written specifications for polymer and metallic materials shall include, as a minimum, the requirements of Table 19. The specification for end fitting epoxy material shall include, as a minimum, trademark, grade, mixing ratio, pot life, molding temperature, and curing temperature and time. Table 19—Requirements of Material Specifications Requirements 6.3.3 Metallic Material Polymer Material Material composition requirements, with tolerances X — Generic base polymer (in accordance with ASTM D1418) — X Physical and mechanical property requirements X X Allowable melting and forming practices X — Heat treatment procedures X — Storage and age control requirements X X Nondestructive examination requirements X X Acceptance and/or rejection criteria X X Certification and records requirements X X Marking, packaging, handling, and traceability requirements X X Storage The manufacturer’s quality plan shall show procedures for handling, storage, and control of raw materials, which reflects the importance of material cleanliness, dryness, purity, and traceability during each stage of manufacture. All raw polymer material shall be protected from contamination and water ingress during handling and storage. Contaminated material shall be rejected. 6.3.4 Traceability Materials shall be traceable and suitably marked for easy identification. In the case of polymer materials, the type of polymer and the supplier’s name and designation shall be identified. The marking of primary end fitting metallic components shall ensure traceability to the base material. 7 Manufacturing Requirements 7.1 Quality Assurance Requirements 7.1.1 General Manufacturing operations shall be performed in accordance with the manufacturer’s written fabrication specifications and manufacturing quality plan, which shall conform to the requirements of Section 7. Processes requiring validation, including welding, heat treatment, and coating, shall be performed in accordance with the requirements of 7.7. The manufacturer shall maintain documentation of the validation of processes for each manufacturing site, that require it, for review by the purchaser or a mutually agreed IVA. Nondestructive examination (NDE) shall be performed in accordance with the requirements of ISO, ASTM, or equivalent standards. 74 API SPECIFICATION 17J Quality assurance requirements for materials to be used in the pipe manufacture shall be as specified in 6.3. All nonconformances shall be included in the delivered as-built documentation. 7.1.2 Process Control All the main steps in the manufacturing process shall be subject to inspection. The manufacturer’s quality plan shall specify inspection points, inspection methods, and acceptance criteria. Results of all inspections shall be recorded. During manufacture, the manufacturer shall take measures to ensure that all measurements are within manufacturer’s tolerances. The manufacturer shall record every nonconformance verified during manufacture of the pipe. All manufacturing nonconformance reports and actions adopted to correct it shall be available for review by the purchaser and included in the as-built documentation; see 8.8. Process control shall be performed as a minimum for the following manufacturing process: a) carcass: preparation and winding of flat steel strip, welding of flat steel strip sections, preforming, cold forming of carcass, reeling of interlocked carcass, preheating, and drying prior to extrusions; b) polymer layers: drying of pellets, extrusion and cooling of polymer, and reeling of sheathed pipe; c) pressure armors: preparation of wire, feeding of pipe, winding of pressure reinforcement, welding of shaped and flat wire sections, and coil reeling; d) tensile armors: preparation of wire, feeding pipe, winding of armor wires, welding of armor wires, application of tape, and coil reeling; e) anti-buckling tapes: winding of anti-buckling tapes and connection methods, e.g. splicing; f) end fittings: mounting process, preparation and cold or hot forming of the armor wires, and resin injection. For each manufacturing condition that is outside the qualified manufacturing procedure because of a nonconformance, qualified engineering personnel shall assess and justify corrective actions and define objective acceptance criteria. Those specific and objective acceptance criteria shall account for the testing, installation, and operation conditions of the flexible pipes. From its own manufacturing experience, manufacturers should anticipate those situations, which require assessment by qualified engineering personnel, and propose clear specific and objective acceptance criteria prior to manufacturing operations, which shall be referred to in manufacturing quality plan submitted to purchaser for approval. In case of new process validation, a sufficient flexible pipe length shall be manufactured in order to document the stability of the process and control of the manufacturing tolerance. 7.1.3 Handling During Manufacture The manufacturer shall have documented procedures for handling of intermediate and finished products during manufacture, packing, and storage. The procedures shall ensure that any anomalies resulting from pipe abrasion, mechanical damage, torsion, bending, and crushing when winding/unwinding pipe on reels and carousels or during end fitting assembly do not exceed manufacturing tolerances. The condition of all reels, carousels, guides, and rollers shall be such that they do not induce any damage to the pipe. Packing shall be checked for center of gravity to ensure that there is no risk of rotating unbalance that could cause unplanned/uncontrolled reel rotation. The manufacturer shall ensure that contamination of the pipe and end fitting due to foreign material is avoided. SPECIFICATION FOR UNBONDED FLEXIBLE PIPE 75 The manufacturer shall use documented procedures for the rewinding of flat or shaped wires from the supplier’s shipping reel to the manufacturer’s reel or bobbin. 7.2 Carcass 7.2.1 General Carcass and carcass insert profile conformance to manufacturer’s acceptance criteria shall be documented at the start and end of each production run and whenever machine adjustments that impact the profile are required. The occurrence of sharp edges in the formed carcass layer shall be prevented. For carcass made up in sections, or when two sections of carcass are joined, e.g. in case of repairs, the join-up procedures for the sections shall be validated for all loads expected at the locations of these connections and documented. The manufacturer shall ensure that the minimum distance between carcass join-up welds shall be specified in the manufacturing quality plan. Carcass join-up welds shall be avoided in fatigue critical areas identified by design analysis (e.g. bend-stiffener region). If such welds cannot be avoided in the fatigue-critical areas, these welds shall be proven to have adequate fatigue performance by analysis and SN testing. The manufacturer shall establish, based on the design methodology and the design criteria for installation loads and effects, a criterion for maximum acceptable ovality after manufacturing. 7.2.2 Inspection and Acceptance Criteria The external surface of the as-formed carcass shall be visually examined for flaws, including dents, cracks, scratches, shavings, gouges, corrosion, scaling, discolored areas (blurring, scorching, staining, and the like, except at welds), distorted or buckled strip profile, and significant scoring. Carcass and carcass insert profiles shall be additionally inspected for lack of interlock at the start and completion of each production run. The carcass profile interlocking shall be checked for freedom of movement. The manufacturer should have acceptance criteria for the allowable freedom of movement. The outside diameter, ovality, and pitch shall be measured and interlock and fishscaling visually checked at the start of the production run and after any running adjustment to machine setup. Subsequent to the start of the production run, these parameters shall be controlled (measured or checked) at least every 10 min for the first 50 min and subsequently at intervals demonstrated by the manufacturer to be acceptable. The manufacturer shall record process data at intervals, agreed with the purchaser, throughout the process. All results shall be recorded and shall be to manufacturer’s specifications, which shall conform to the tolerance requirements of 7.8. During the production run, the carcass shall be checked for fishscaling. The average pitch of the carcass over the length of the finished pipe shall be provided. On specific request and when feasible, carcass pitch shall be measured and documented during/after end fitting termination from both ends. 7.3 7.3.1 Polymer Extrusions General Extrusion of thermoplastic material shall be performed in accordance with the manufacturer’s documented procedures. Each extrusion shall be controlled in accordance with an approved setup sheet that provides settings for all essential variables based on the material and sizing of the product. The manufacturer shall have documented records to show that detrimental folding does not occur in the layer for the polymer material and wall thickness to be extruded. 76 API SPECIFICATION 17J The manufacturer shall ensure that, for rough bore pipes, all extrusions are onto an underlying layer whose external surface conforms to the manufacturer’s extrusion procedures. Surface undulations of all extruded layers or ingress into underlaying layers shall be controlled and kept within the design limits to avoid any unintended impact on the under- and/or overlaying layers. The Kt value shall be verified to be within the manufacturer’s validated range from material qualification when required as an input for polymer fatigue damage assessments. During extrusion of flexible pipes exposed to FLIP and all dynamic flexibles (risers and jumpers), the supplier shall ensure that the average carcass pitch is within the specified tolerances at least within every 10 min for the first 100 min of the extrusion process and within each 100 min thereafter. During extrusion, the following process parameters shall be monitored and recorded and shall conform to the manufacturer’s specifications: a) temperature and pressure (or dew point) of raw material humidity control equipment, b) extruder-screw feeding rate (or screw revolutions per minute), c) extruder-barrel temperatures, d) extruder-barrel pressures, e) extruder-crosshead temperatures, f) extruder-crosshead pressures, g) rate of travel, h) quenching water temperature. The manufacturer shall test and ensure that the moisture content of hygroscopic materials is within supplier-specified tolerances prior to commencing the extrusion process. If PA or thermo-plastic elastomer (TPE) is used, the moisture content shall be tested in accordance with ASTM D6869 or equivalent procedures and shall be to the manufacturer’s specifications. Procedures and tools used for perforation of intermediate layers for gas-venting purposes shall not induce defects in underlying layers. Perforation by melting with heated tooling is preferred. Cutting procedures shall be documented not to cause crack initiation points or otherwise weaken the area of cutting such that the functional requirements of the polymer layer or its underlaying layers are violated. The manufacturer shall document procedures in the fabrication to control the following processes: a) surface grinding, b) processes to remove plasticizer, c) cross-linking, d) stress relieving, e) other processes requiring validation. SPECIFICATION FOR UNBONDED FLEXIBLE PIPE 7.3.2 77 Inspection and Acceptance Criteria 7.3.2.1 Visual Examination The manufacturer’s specifications shall document acceptance criteria for flaws as a function of category (individual or cluster), size, position in material thickness, distance between flaws, and number. A visual examination of the entire polymer layer external surface shall be performed to identify flaws that may act as a weak spot or stress concentrator including holidays, bubbles, inclusions (black spots), discoloring, undulations, extrusion weld lines, die scratches, die drools, notches, and indentations. All flaws shall be in accordance with the manufacturer-specified acceptance criteria. The definition and acceptability of the above flaws shall be documented by the manufacturer and shall be objective. The maximum dimensions of each flaw or combination of flaws shall be such that the total remaining thickness of the layer shall be at least equal to the minimum design thickness. 7.3.2.2 Dimensional Measurements The manufacturer shall record process data at intervals agreed with the purchaser throughout the extrusion process. Thickness and diameter measurements of the extruded layers and their location shall be recorded. These shall be throughout the whole extrusion at intervals of 90° or less around the circumference. If different measuring systems exist, an order of precedence shall be clarified. If automated measurement is used, it shall be regularly recalibrated. In this case, should a sensor malfunction, the average of the two adjacent values along the pipe length may be considered if the measurement by working sensors is made at intervals of 90° or less around the circumference. Diameter measurements shall also take due account of the effects of ovality on the measured diameter. Measurements shall be performed at a location after passing through the cooling-process equipment and before take up onto reel or carousel. 7.3.2.3 Test Requirements For extrusion onto a metallic layer, the extruded internal pressure sheath shall be subject to a continuous high-voltage spark test or equivalent test, calibrated to detect a 1 mm (0.04 in.) or smaller hole. The holiday detector shall be calibrated prior to the extrusion of the polymer layer material and thickness that is extruded. The detector shall be provided with an audible alarm. For each extrusion of the internal pressure and outer sheath layers, a minimum of three polymer test coupons shall be taken from both initial and final extruded sections and subjected to tensile test in accordance with the procedures specified in Table 16. Additionally, for pressure sheaths, PA test coupons samples shall be subjected to corrected inherent viscosity (CIV) measurement in accordance with manufacturer procedures. Acceptance criterion shall be in line with API 17TR2 as applicable. Cross-linked polyethylene (XLPE) coupons shall be tested to check that the cross-linking process has been performed successfully. The polymer test coupons shall be stored at ambient temperature for a minimum of 6 h prior to testing. All test results shall be recorded and shall conform to the manufacturer’s specifications. 7.4 7.4.1 Pressure and Tensile Armor Layers General The manufacturer shall have documented procedures for the winding of the pressure armor and tensile armor layers onto the pipe, which shall ensure that the flat, round, or shaped wires are laid to the design requirements. The procedures shall include requirements for the condition of the wires prior to winding and for the condition of the finished layer, such that the layer and underlying or overlying layers meet the manufacturer’s specifications. The procedures shall specify all parameters and allowable tolerances that are to be monitored and recorded at intervals verified by the manufacturer to be acceptable. The recorded values shall conform to manufacturer’s specifications. As a minimum, diameter and pitch (or lay angle) shall be measured, as well as 78 API SPECIFICATION 17J the ovality of the pressure armor. The ovality requirement does not apply to backup pressure armor layers. During the production run, pressure and tensile armors shall be checked against fishscaling or wires that exceed allowable tolerances. The manufacturer shall be in control of the accumulated plastic strain and residual stresses imposed in the manufacturing process, and this shall be addressed in design. All welds shall be staggered along the length of the pipe in conformance with the manufacturer’s specifications, which shall specify a minimum separation between welds. Welds in the pressure and tensile armor wire shall be avoided in the fatigue-critical areas identified by design analysis (e.g. bend-stiffener region). If welds on the pressure and tensile armor wires cannot be avoided in the fatigue-critical areas, these welds shall be proven to have adequate fatigue performance by analysis and SN testing for the same annulus condition. Lubricants used in the pressure and tensile armor wire forming process, storage protection, and winding onto pipe shall be demonstrated to have no deleterious impact on the armor wire or interfacing layers material properties upon completion of the pipe production for the specified service life. 7.4.2 Inspection and Acceptance Criteria The external surface of the as-formed pressure and tensile armor layers shall be visually examined for flaws, including dents, cracks, scratches, shavings, gouges, corrosion, scaling, discolored areas (blurring, scorching, staining, and the like, except at welds), distorted or buckled wire profile, and significant scoring. The outside diameter, pitch (or lay angle), ovality, and the circumference (to confirm there is no gap between pressure armor and internal pressure sheath) of the pressure armor shall be measured and recorded at least every 10 min for the first 50 min and subsequently at intervals verified by the manufacturer to be acceptable and during each stop/reversal cycle. Diameter measurements shall take due account of the effects of ovality on the measured diameter. The results shall be within the tolerances specified in 7.8. Armor layers shall be additionally inspected for wires on edge, fishscaling, and wire twist. 7.5 7.5.1 Antiwear, Insulation, and Anti-buckling Tape Layers General The manufacturer shall ensure that antiwear layers, taped layers used as manufacturing aids, insulation layers, and anti-buckling tapes are applied in accordance with documented procedures. The procedures shall include requirements for control and monitoring of antiwear tape or anti-buckling tape application and overlap of extruded profiled strip and shall document acceptance criteria for flaws. 7.5.2 Inspection and Acceptance Criteria The external surface of the antiwear, insulation layers, and anti-buckling tapes shall be visually examined over the entire length for flaws, including damage, distortion, folds, and lack of interlock (for profiled insulation strip). Identified flaws shall conform to the manufacturer’s specifications. Lack of interlock in profiled insulation strip layers shall not be acceptable. The outside diameter shall be measured and recorded. The pitch and width or lateral gap or overlap (between adjacent layers) of anti-buckling layers shall be measured and recorded during setup and at each stop for change. These measurements shall be subsequently verified at intervals by the manufacturer to be acceptable. The results shall be within the tolerances specified in 7.8. For multiple anti-buckling tape layers, no radial gap shall be allowed between each anti-buckling tape layer. SPECIFICATION FOR UNBONDED FLEXIBLE PIPE 7.6 End Fitting 7.6.1 General 79 All operations in the manufacture, machining, assembly, and inspection of end fittings shall be performed in accordance with the manufacturer’s specifications, which shall meet the requirements of 7.6. All fitting operations shall be performed by personnel (end fitters) qualified in accordance with the manufacturer’s approved procedures. The qualifications of end fitters shall be documented and shall be available for review by the purchaser and by the IVA. 7.6.2 Assembly Before mounting the end fitting on to the pipe, all exposed surfaces shall be cleaned, dried, visually inspected for defects and corrosion, and confirmed to be in accordance with the requirements of the manufacturer’s specifications. Lubricants used during tensile armor formation shall be cleaned if relevant for the mounting procedure and if applicable depending on design assumptions. In the preparation of the internal pressure sheath under the end fitting seal ring, any machining of this area shall not introduce unacceptable notches or reduce the thickness of the sheath to less than the minimum design thickness. Acceptance criteria for out-of-roundness, wall thickness variations, and surface roughness in this area shall be specified. The crimping/sealing performance for each sealing location shall be documented around the circumference, based on as-built dimensions, tolerances and seal position, and deformation in order to be within qualification range. Control features shall be established and documented to ensure that overheating of epoxy or polymer layers is prevented during welding operations. Any permanent welding procedures (e.g. tack welding) used to maintain the armor wire configuration shall be carried out under controlled conditions. All welded surfaces shall be ground smooth and examined for cracks in order to avoid damage to adjacent layers or components. Prior to mixing the epoxy resin, all equipment required for the filling operation shall be checked for proper functioning. The mixing and curing of epoxy resin shall be in accordance with the supplier’s specifications. Filling shall be carried out in such a way that unacceptable voids or gaps do not occur. Gas-vent tubes in the end fitting shall not be obstructed by the epoxy. Any resin cure process that requires the heating of the end fitting shall be carried out with proper temperature control. All tensile armor wire profile forming processes in end fitting assemblies that change the wire mechanical and geometric characteristics in the end fitting shall be controlled and documented. Wire profile forming processes shall be carried out by using a former as a guide to radius control. During wire forming, the orientation of the wires and distribution of gaps between them shall be controlled. If heating is used during wire forming, temperature shall be controlled or the heating process qualified and also taken into account during design. These controls shall be part of the manufacturer assembly procedures. The manufacturer shall have documented procedures in the fabrication specification for dimensional control of the cutting processes for the armor and end fitting assembly parts to assure that there is no gap that could allow creep of the internal pressure sheath in excess of that specified in Table 8 during hydrostatic pressure testing and in operation. 7.6.3 Inspection and Acceptance Criteria For the end fitting assembly, hold points or witness point shall be included where visual examination, dimensional control, and component identification are performed. The type of surveillance for each step shall 80 API SPECIFICATION 17J be agreed with the purchaser. Results from all inspections shall be documented and included in the as-built documentation. For components requiring a specific tightening force or torque, it shall be verified using suitable and calibrated equipment that the specified value has been obtained. The manufacturer shall use a validated and documented procedure to verify that sufficient epoxy resin has been injected into the end fitting, such that no voids are left in the end fitting that would affect its functional performance. Control of resin injection shall include as a minimum resin composition, mixing process, injection duration, and curing time. The volume injected shall be checked. 7.6.4 Test Requirements Minimum test and inspection requirements for primary end fitting components shall be as follows, and all results shall be in accordance with manufacturer’s specifications: a) all accessible surfaces: 100 % visual examination; b) carbon and low-alloy steel accessible surfaces: 100 % magnetic particle or liquid penetrant inspection when geometry prevents MPI; c) weld overlay surfaces: 100 % liquid penetrant, thickness, adhesion, hardness; d) end fitting bodies: 100 % ultrasonic test; e) circumferential butt welds: 100 % radiographic test or 100 % phased array ultrasonic testing (PAUT); f) coating: 1) paint and epoxies—thickness, adhesion; 2) electrochemical deposition coatings—chemical composition, metallography of the interaction between base material and coating, liquid penetrant; 3) autocatalytic electroless deposition coatings—chemical composition, thickness, inter-diffusion, residual stress, impact test, bending tests, visual examination. Samples for mechanical testing shall be taken in representative locations of the forged material. Type, number, location, and orientation of tests shall be documented either in a dedicated sketch or in a procurement specification. As part of epoxy resin injection, a minimum of one sample consisting of five specimens shall be taken from the same mix as used for the end fitting. Compression strength tests shall be carried out in accordance with ASTM D695 procedures. The compression strength shall be above or equal to the minimum specified by the manufacturer for the cured epoxy. Alternative methods to ASTM D695 may be used as long as they are proven to be equivalent to ASTM D695 or provide more stringent results. 7.6.5 Connectors All end fitting connectors and components shall be in accordance with API 6A, API 17D, other recognized industry standard, or as specified by the purchaser and shall meet the requirements specified in 4.6.1.9. SPECIFICATION FOR UNBONDED FLEXIBLE PIPE 7.7 81 Processes Requiring Validation 7.7.1 Welding 7.7.1.1 Validation All welding operations shall be performed by qualified welders in accordance with the manufacturer’s approved procedures. Welding procedure specifications (WPSs), welding procedure qualification records, and welder qualifications shall be documented and shall be available for review by the purchaser. Welding procedure validation shall be witnessed and approved and records of welder qualification shall be reviewed by an IVA who is qualified to witness and approve the standards and criteria being used. For welding performed with automated processes or for welds that serve only as manufacturing aids, the IVA of welder qualifications may be substituted by an American Society for Nondestructive Testing (ASNT) qualified Level II inspector. Welders shall be qualified and welding procedures shall be validated in accordance with one of the following standards: ASME Boiler and Pressure Vessel Code Section IX, ISO 15614-1, ISO 13847, or equivalent. Procedures shall include acceptance/rejection criteria. NOTE For the purposes of this provision, API 1104 is equivalent to ISO 13847. As a minimum, qualification testing for flat, round, and shaped wires to be used for sweet-service applications shall include visual inspection, MPI, two tensile tests, and either two-face or side guided-bend tests. The weld tensile test results shall have an ultimate tensile value equal to or greater than the minimum acceptable weld tensile value established by the manufacturer for the design application. Minimum tensile values shall be included in the WPS. The diameter of the guided-bend test mandrel shall be such that sufficient mechanical stress is introduced in the weld zone to show weld quality. For sour service, in addition to the above testing, a macro and hardness survey shall be performed. The macro shall be polished, etched, and examined at a minimum of 10× magnification. Hardness tests shall be performed on the same sample. One test each, as a minimum, shall be made in the fusion or bond line, heat-affected zone (HAZ), edge of HAZ, and unaffected base metal. Hardness test shall be to HV5 or HV10 (ISO 6507-1) or HV500 (ASTM E384). Results of all tests shall be in accordance with the manufacturer’s specifications. The manufacturer shall have documented procedures for storage, handling, and drying of welding consumables. 7.7.1.2 Metallic Layers Every time there is a change in welding machine setup, a minimum of two test welds shall be made to verify the setup. The samples shall include all production heat treatments. The sample welds shall be subjected to the following tests as a minimum: a) ultimate strength, b) hardness (sour service), c) bend, d) dye-penetrant or magnetic particle, e) visual examination as specified below. The hardness test shall be performed in the area that will be submitted to the maximum cold deformation during process. The dye-penetrant test is required for nonmagnetic alloys and the magnetic particle test is required for magnetic steel grades, and the test shall be performed after the bend test. Visual examination at 5× magnification of the weld HAZ at the outer surface of the bend may be used as an alternative to the magnetic 82 API SPECIFICATION 17J particle test. The hardness test shall be performed in the area with maximum cold deformation. For carcass strip welds, only visual examination is required. Results from all tests shall be documented and shall be within the manufacturer’s specifications. Production welds shall exhibit a smooth surface across the full strip width and show full penetration. There shall be no cratering, edge washing, or burn-through of the strip. The weld thickness shall be, as a minimum, that of the sheet thickness and shall be maximum 1 mm (0.04 in.) above the surface. The weld shall be consistent across the strip with no undercut at the toes. For carcass join-up welds, the manufacturer shall ensure that all weld metal is ground smooth to prevent damage to extruded overlying layers. Butt welds for joining carcass and armor layer wires and strips and for carcass join-up welds shall be subjected to the following inspection requirements: a) carcass strip: 100 % visual examination, b) carcass join-up: 100 % visual examination, c) steel wire: 100 % visual examination and magnetic particle test. The 100 % visual examination shall be performed prior to the steel’s passing through the machine forming tools. The external surface of the weld shall also be examined for cracks after passing through the forming tools. Cracks shall not be allowed. Butt welding of shaped wires shall utilize automatic or semiautomatic welding devices. 7.7.1.3 Polymer Layers Repair welding of polymer layers, as permitted under the requirements of 7.9, shall be performed in accordance with the manufacturer’s validated procedures, which shall be available for review by the IVA and purchaser. The welding procedures shall contain acceptance/rejection criteria. Inspection of polymer weld repairs shall check that the layer wall thickness and surface conditions conform to the manufacturer’s specifications. 7.7.1.4 End Fitting All circumferential butt and overlay welds shall be performed in accordance with validated and documented procedures. Inspection and test requirements shall be as specified in 7.6.4. 7.7.2 Heat Treatment Wires and cold-worked or forged components that require heat treatment in order to meet specified requirements for strength, formability, or NACE compliance shall be heat treated in accordance with the manufacturer’s specifications. The heat treatment procedures and chart shall be maintained by the manufacturer or subcontractor for review by the purchaser. 7.7.3 Coating Coatings applied to end fitting components to limit corrosion due to internal, external, or annulus environments shall be applied in accordance with the manufacturer’s documented procedures, which shall include acceptance and rejection criteria. In addition, the procedure for qualification of the electroless nickel coating processes to be applied to the end fitting shall specify the following as a minimum: SPECIFICATION FOR UNBONDED FLEXIBLE PIPE 83 a) bath composition; b) control of temperature and time for heat treatments; c) hardness test of coating; d) adhesion test of coating; e) optical microscopy or a similar method recommended to analyze the cross section of the coated surface; f) coating thickness measurement; g) testing to confirm the resistance of coating to corrosion agents (e.g. seawater and CO2); h) procedures for checking surface coating for flaws; i) 7.8 coating repair method and qualification, if any. Manufacturing Tolerances The manufacturer shall document the tolerances to be used for each layer of the flexible pipe. These tolerances shall be verified in the design process to be acceptable, such that the functional requirements of the individual layers and pipe are unaffected by variations within the specified tolerances and changes in utilizations are in accordance with 5.2. As a minimum, tolerances shall be specified for the following parameters: a) carcass: external diameter, ovality, fishscaling, and average as-built carcass pitch (after extrusion and cooling down of pressure sheath as specified in 7.3.1); b) polymer sheaths: thickness and external diameter; c) pressure armors: external diameter, ovality, pitch (or lay angle), and fishscaling; d) tensile armors: external diameter, pitch (or lay angle), and fishscaling; e) anti-buckling tapes: pitch and width or lateral gap and overlap (between adjacent layers). The tolerance for the length of the flexible pipe shall be specified. For pipes without pressure armor, the manufacturer shall demonstrate that tensile armor wire gaps are controlled such that the design requirements are met. For Family I (per API 17B, Table 2) pipes, the pressure sheath wall thickness shall be measured at the beginning and at the end and with continuous OD measurements. These parameters are used indirectly to control continuously ID. If dimensional criteria are based on manufacturing considerations rather than design considerations, the manufacturer shall document that the criteria used meet the design requirements. 7.9 Repairs The manufacturer shall have documented, validated procedures for performing repairs, either during manufacture or on the finished product, and these procedures shall be qualified and be available for review by the purchaser. The repair procedure shall be validated to be executed in the actual conditions that the flexible pipe may experience. The manufacturer shall document by additional tests and/or calculations that the repairs to the flexible pipe do not compromise the structural or long-term requirements of the pipe. 84 API SPECIFICATION 17J Repair of the internal pressure sheath or anti-collapse sheath is not permitted. Unacceptable defects found in this layer shall result in complete removal of the layer. Removal procedures are subject to review by the purchaser. Rework by machining of the internal pressure sheath may be carried out to remove superficial discontinuities or localized excessive thickness, provided that the final thickness complies with the specified layer tolerances and that a proper surface finish is assured. Repair of minor flaws in intermediate or external polymer layers, but not any pressure-containing layers, is permitted. Polymer welding shall be performed as specified in 7.7.1.3. All repairs, including offshore repairs of outer sheaths, shall be performed in accordance with validated procedures and qualified personnel and shall not introduce defects into underlying layers. Outer sheath repair shall not result in OHTC exceeding the requirements of 4.6.1.4 and 5.4.3 due to damage to the insulation. Any defects in armor metal welds shall be repaired by cutting out the weld and HAZ and rewelding according to the specified procedures. Carcass weld repairs are permitted, provided a validated repair procedure is used and visual inspection confirms the weld repair is acceptable. Inspection requirements for repair welds shall be as specified in 7.7.1. Procedures for repair of damage to surface protection coatings shall be available for review by the purchaser. Butt weld repair shall comply with all the applicable required guidelines of API 6A, product specification level (PSL) 2 and PSL 3 unless PSL 4 is specified by the purchaser. (See Table A.1.) Tooling used for removal of defective layers inclusive of anti-buckling tapes shall be such that defects are not introduced into underlying layers. Special care is required when removing an extruded sheath to avoid contact between the cutting tool and underlying armors. 8 Documentation 8.1 General The minimum documentation that the manufacturer is to have available for the purchaser shall be as specified in Section 8. The documentation requirements for materials and manufacturing shall be as specified in the relevant subsections of this specification. The manufacturer shall have available for the purchaser the following documents and should have them available at the specified times, unless otherwise agreed between manufacturer and purchaser: a) design premise: prior to pipe design; b) design load report: prior to manufacture; c) design report: prior to manufacture; d) pipe datasheet: prior to pipe manufacture; e) manufacturing quality plan: prior to manufacture; f) fabrication specification: prior to manufacture; g) as-built documentation: before delivery of the pipe and any time on request; h) operation manual: prior to delivery; i) qualification test procedures: prior to test run (if production tests are required); SPECIFICATION FOR UNBONDED FLEXIBLE PIPE j) 85 qualification test reports: before commencement of manufacture or before the delivery of (if production tests are required) the pipe, as per contractual agreement; k) TAC as described in 11.2.6, prior to manufacture; l) independent design review certificate (IDRC) prior to manufacturing whenever required (described in 11.3.2); m) certificate of conformity (COC) prior to the delivery whenever required (described in 11.3.3). 8.2 Design Premise The design premise shall contain the parameters specified in Table 20. If the manufacturer has made assumptions on any of the parameters in Table 20, then it shall be specified in the design premise that the values are assumed. The design premise shall include all technical requirements and recommendations contained in the purchaser specification. Table 20—Documentation Requirements for the Design Premise Parameter Comments Internal fluid parameters All relevant internal fluid parameters, including, as a minimum, the parameters specified in Table 1. External environment All relevant external environment parameters, including, as a minimum, the parameters specified in Table 4. System description All relevant system parameters, including as a minimum, the parameters specified in 4.6. Service life Including, where relevant, maintenance and replacement programs. Design load case combination All potential load cases for the flexible pipe system during manufacture, storage, transport, testing (including lower safety factors as applicable), installation, operation, and retrieval shall be addressed. A matrix showing the load cases to be checked for each component of the flexible pipe system shall be established and shall conform with the requirements of Section 5. Design accidental events All accidental events and combinations of accidental other loads (functional and environmental) shall be specified. The load cases shall be included in the load case matrix. Design criteria Required safety margins and definitions of structural capacity shall be specified for each layer of the pipe and components and shall conform with the requirements of Section 5. These shall include hydrodynamic coefficients, structural parameters, and seabed Analysis methodologies and parameters; regular/irregular wave approach, extreme value; consideration of currents and relative wave-to-vessel headings for fatigue and interference analyses; and verification of parameters critical analysis assumptions. Software tools All software tools intended for use for the identified analysis methodologies including global pipe configuration tools and local component stress/strain/deflection tools. The verification and validation of each software tool shall be available for purchaser review. Failure mode effects and criticality analysis (FMECA) Per FMECA definition. 8.3 Design Load Report The design load report shall include results from analyses of load cases defined in the design premise. Calculated stresses and strains shall be reported for each design load case. The design load report may be incorporated into the design report. For dynamic applications, this report shall describe the extreme, fatigue, and interference analyses and shall compare the results from those analyses with the relevant acceptance criteria. 86 API SPECIFICATION 17J When applicable, the report shall include results from analyses of upheaval buckling and lateral pull-back and document pressure and temperature expansion coefficients and associated internal pressure area, as well as pipe variation of axial and bending stiffnesses with pressure and temperature. 8.4 Design Report The design report shall contain a detailed description, including drawings, of each pipe component. The description shall include a layer-by-layer description of the pipe, including specification and properties (original mechanical properties, “as-specified” in the mill/subvendor plant, and those considered for dimensioning the pipe, e.g. after forming process in the pipe) materials, wire cross section, lay angle, diameter, thickness, and number of wires. Manufacturer shall also provide winding angle and details of overlap of anti-buckling tapes. Unless separate material specification documentation is issued, material specification and data shall be included in the design report. Material data shall include yield or tensile strengths and fatigue parameters for dynamic service (S-N curve slope, intercept, and endurance limit) and shall identify fluid components that can adversely affect the material. Each component shall be documented to have sufficient structural capacity to sustain the design loads and stresses listed in the design load report, for nominal dimensions and EOL conditions, with the safety margin specified in the design premise and agreed with the purchaser. The design report shall define or record the conditions, features, capacities, or properties listed below for the flexible pipes. The design report shall include schematic drawings of the layer-by-layer pipe structure and end fittings. Wherever mentioned, “permissible” means a maximum load to which the pipe can be subjected without any damage or restrictions for future use including its service life. The cause, origin, and location of the predicted damage or restriction shall be included in the report. The report shall also include: a) diameters (internal and external); b) weight per meter (in-air empty and seawater filled, and in-seawater empty and seawater filled); c) internal and maximum design pressures; d) design temperatures; e) design water depth; f) MBR (storage and operating); g) LR (or max/min gap for non-interlocked pressure armors); h) axial stiffness (in both tension and compression, and as a function of pressure and temperature); i) bending stiffness and a bending moment vs curvature curve (hysteretic loop) at defined combinations of tension, pressure, and temperature, as specified by the purchaser; j) torsional stiffness (as a function of twist direction, tension, pressure, and temperature when applicable and requested by the purchaser); k) collapse resistance of the internal pressure sheath (for smooth bore pipes) when requested by the purchaser; l) collapse resistance of rough bore structures in bent configurations considering hydrostatic pressure applied to outer sheath, intermediate sheath if applicable, and pressure sheath; SPECIFICATION FOR UNBONDED FLEXIBLE PIPE 87 m) permissible tension (as a function of bend radius when applicable and requested by the purchaser); n) permissible axial compression and curvature (under static and dynamic loading as applicable) associated with intact annulus/annulus flooded with seawater for pipe empty or full of minimum design density fluid as applicable; o) permissible crushing (radial), associated with the squeeze effect from the tensile armors, for the pipe section under the loading induced by the specified laying equipment, pipe empty and full of seawater; p) minimum squeezing (radial) load to prevent pipe slippage during installation with the specified laying equipment; q) permissible twist as a function of tension (capacity chart) and for expected installation and handling conditions; r) axial and radial expansion or contraction induced by the maximum design pressure and design minimum and maximum temperature; s) induced twist due to maximum design pressure and design tension; t) results of the global, service life and local analyses for the specified installation, service, and retrieval phases for pipe under new and degraded conditions (including at the end of service life on request); u) pipe hydrostatic collapse and buckling resistance for a straight pipe and a pipe at operating bend radius (OBR) at design water depth, considering the effects of the crushing loads from the specified installation methods, equipment, and conditions and intact annulus and annulus flooded with deaerated seawater; v) drawings (not including manufacturing drawings), specification and properties of materials, data used in calculations, accurate dimensions regarding interfaces, and design calculations of end fittings, ancillary components, and accessories (fatigue included for items subjected to relevant dynamic loading); w) restrictions imposed by collapse and buckling resistance, such as — requirement to install empty/full, — temporary storage requirements (onshore or on the seabed), — allowable linear depressurization rate; x) coefficients of friction which will be considered for installation sequence. Those coefficients of friction shall be clearly documented including all impacts related to: — materials, geometry, and other relevant data of the interface between the pipe and specified laying equipment; — temperature; — contact pressure; — presence of water. The IVA’s TAC for the design methodology (see 11.2) shall be included in the design report. 8.5 Pipe Datasheet The pipe datasheet shall provide a detailed description of the layer-by-layer cross section configuration of the flexible pipe and also information on which extruded layers are sealed at the end fitting, indicating the class of 88 API SPECIFICATION 17J each annulus, as per Table 9. For each steel layer, the number of wires, lay angle, and structural capacity shall be provided. NOTE 8.6 Guidelines on the minimum requirements for flexible pipe datasheets are given in Annex B. Manufacturing Quality Plan The manufacturing quality plan shall specify all quality control procedures, including process control, inspection points, manufacturing tolerances, and test procedures, as per Section 7. The manufacturing quality plan may be included in the manufacturer’s fabrication specification. 8.7 Fabrication Specification The manufacturer’s fabrication specifications shall ensure that the pipe is in accordance with the design. The manufacturer’s fabrication specifications shall document the following as a minimum: a) layer-by-layer and step-by-step description of the manufacturing procedures, including quality control, welding, heat treatment, type and extent of NDE and acceptance criteria, FAT procedures, fabrication method, and allowable repair procedures, for the complete flexible pipe (i.e. all layers, sublayers, lubricants, tapes, anti-buckling tapes, end fittings, and any other items forming an integral part of the final product); b) procedures for processes requiring validation; c) references to specifications and traceability of all materials used in the manufacture of the flexible pipe, including the materials used for the manufacture of the layers and materials such as lubricants, corrosion-coating materials, antiwear, and nonmetallic tapes; d) all parameters related to the quality of the final product that can be monitored during the manufacturing process. Both nominal values and ranges of these parameters shall be specified; e) procedures for dimensional control of the layer termination processes (e.g. cutting of pressure armor wires) and of end fitting assembly to avoid gaps into which pressure sheath extrusion can occur during hydrostatic pressure testing and operation; f) procedures for dimensional control of the cutting processes for the pressure armor and end fitting assembly parts; g) all processing that converts or affects material properties, including extrusion, welding, and plastic deformation of metal. The specification shall include a statement of applicable scope, limits on critical process parameters, inspection and test methods, and acceptance/rejection criteria. The manufacturer’s fabrication specifications shall be approved by the engineering and manufacturing personnel designated by the manufacturer. Documents shall be maintained available for check by the IVA. The manufacturer’s fabrication specifications shall be controlled documents and shall be readily available to the process machine operator. The manufacturer shall keep on file throughout the specified service life of the pipe all documentation pertaining to the pipe manufacture, including manufacturing records, certificates, inspection, and FAT documentation. 8.8 As-built Documentation The as-built documentation shall include, as a minimum, the following: SPECIFICATION FOR UNBONDED FLEXIBLE PIPE 89 a) purchase order reference number; b) equipment descriptions; c) references to design specifications and drawings; d) certificates of conformance for all materials included in the flexible system; e) dimension control measurements; f) FAT results; g) FAT methods and results for testing of intermediate sheath sealing in end fittings when required in Section 9 and depending on annulus class as per Table 9; h) all reports of nonconformities identified during manufacture, repairs, and inspections performed after repairing, including the traceability of the affected region and its location with respect to the pipe end fitting or position in the accessory; i) WPSs and validations; j) welder qualification records; k) weld map for dynamic applications. For static applications, when agreed with the purchaser, the weld map may be omitted; l) NDE operator qualifications and NDE test records; m) heat treatment records; n) pipe maximum and minimum OD and length between end fittings; o) drawings of ancillary components and accessories, indicating dimensions, safe working load, weight, and summarized assembly instructions (specified torque bolts); p) drawing to include order of priority direction vs. ancillaries/datum placement (e.g. touchdown point based on installation from seabed or topside end); q) calculated residual wire stresses post FAT and OLT. 8.9 Operation Manual The operation manual shall be prepared for the system and shall address all maintenance tasks and restrictions, and emergency procedures, as specified by the manufacturer or purchaser. The manual shall include the following as a minimum: a) the pipe datasheets; b) installation, retrieval, and commissioning requirements and limitations, including OLT and offshore SIT (e.g. limitations for pipes designed to the differential pressure at the water depth of one field being deployed at another field of different water depth where applicable); c) interface requirements; d) handling, storage, winding/unwinding procedures, and limitations including recommendations for preserving products and spares and handling recommendations to avoid torsion buildup in the flexible pipe sections indicating torsion limits and how to assess them; 90 API SPECIFICATION 17J e) gas-venting system description, installation and operation, and permeation rate and expected onset of venting after start-up with maximum operating pressure and temperature; WARNING—The maximum pipe retrieval rate should be determined to allow accumulated gas to safely escape from the pipe annulus. The requirement related to installation check of gas-vent plugs or gas-relief valves for different phases (e.g. installation, service, recovery) shall be determined by manufacturer. f) allowable pressurization/depressurization rates with associated durations related to type of structure or service—water gas or multiphase; g) outer sheath burst pressure; h) restrictions on internal fluid components including H2S, CO2, acids, bromides, amines, and inhibitors; i) pigging and TFL capabilities and relevant restrictions (pigging is generally not recommended for smooth bore pipes); j) allowable maximum loads and top angle (risers); k) maximum time with seawater or inhibited seawater in pipe and inhibitor requirements; l) reference for as-built documentation; m) detailed in-service inspection, monitoring, and maintenance/replacement plan, including failure detection systems description with fault identification and acceptance criteria, where relevant. Plan to include inspection frequencies and focus on inspecting the pipe system components of highest strength and fatigue utilizations identified during design, manufacturing, and FAT. FMECA based on such strength and fatigue utilizations, and on repairs during manufacturing, is to be included if specified by the purchaser; n) maximum duration allowed before performing a repair in the event of outer sheath damage leading to aerated seawater in the annulus; o) collapse resistance of the internal pressure sheath for smooth bore pipes when requested by the purchaser; p) schematic overview/composition drawings of the flexible pipe system (from end fitting to end fitting, inclusive), including ancillaries together with key dimensions and references; q) packing drawing with unpacking instructions; r) maximum allowable pressure difference over a local blockage (e.g. a hydrate plug) and the safety factor, where applicable. The operation manual shall include all flexible pipe and flexible pipe system limitations identified by the manufacturer having regard to the safety, including pressure and temperature limits and testing as defined in the design report. If specified by the purchaser, a separate installation manual shall be supplied, and this shall document the installation procedures. If specified by the purchaser, a separate repair manual shall be supplied, and this shall document repair procedures, including those applicable during installation. The procedures shall contain the list of required equipment, materials, qualified personnel, logistic, and facilities. SPECIFICATION FOR UNBONDED FLEXIBLE PIPE 9 Factory Acceptance Tests (FATs) 9.1 General 91 The flexible pipe shall be subjected to FATs, including gauge, hydrostatic pressure, electrical continuity, electrical isolation, gas-venting system, and sealing tests, as applicable, to verify the manufacture of the pipe to the requirements of this specification. The hydrostatic test shall be required for all pipes. The electrical continuity and electrical isolation tests shall be required for pipes that are cathodically protected. The gauge and electrical isolation tests are applicable only to rough bore structures. The gas-venting system and sealing tests shall be required for pipes that have gas-relief valves or ports installed in the end fittings. The external sealing tests shall be required for all flexible pipes designed with a guaranteed intact annulus. Table 21 summarizes the required tests. NOTE For test samples, not all FAT specified in Table 21 may be required. The manufacturer’s specifications shall specify the minimum time that shall elapse between the completion of the end fitting mounting (including epoxy curing) and the start of the acceptance tests. The acceptance test program shall comply with this minimum time. A report for each acceptance test shall be submitted to the purchaser. Current certification/calibration certificates for all test equipment shall be included in the test report. All pressure-recording equipment shall be calibrated against a deadweight tester at least every 3 months. Data recordings shall where possible be of digital type with appropriate time resolution vs acceptance criteria—this includes e.g. hydrostatic pressure test, gas-venting system test, and sealing test. Analog backup records, where nonredundant digital sampling is applied shall be provided both as original hardcopy and digital scan. Records shall where relevant include original photographic material in addition to reproductions in documents/reports. For hydrostatic pressure test guidance, see also API 17B, Test Records. If the acceptance criteria for a test are not met, the cause of the failure shall be investigated and a report submitted to the purchaser. Proposed corrective action shall be included in the report. Table 21—Factory Acceptance Test Without cathodic protection With cathodic protection End Gas-venting Sealing Fitting Sealing System Test Test Test Gauge Test Hydrostatic Pressure Test Electrical Isolation Test Electrical Continuity Test Rough bore X (1) X n/a (1) n/a X X (2) X(3) Smooth bore n/a X n/a n/a X X (2) X(3) Rough bore X X X X X X (2) X(3) Smooth bore n/a X n/a X X X (2) X(3) NOTE 1 X—required; n/a—not applicable. NOTE 2 The sealing test is required for risers and optional for other applications. NOTE 3 Test to be performed unless the pipe cross section is intentionally flooded during installation or if accidental flooding is acceptable by design. 9.2 Gauge Test 9.2.1 Purpose The purpose of the gauge test is to detect blockages and any gross deformations. 92 9.2.2 API SPECIFICATION 17J Procedure The gauging pig shall be equipped with disk(s) capable of detecting any unacceptable obstruction. The minimum diameter of the gauging pig shall be at least 95 % of the nominal ID or 10 mm (0.39 in.) smaller than the ID for pipes with an ID less than 200 mm (7.87 in.). The thickness of the gauging disk shall be between 5 mm and 10 mm (0.20 in. to 0.39 in.). Gauging is not required when the flexible pipe has recessed end fitting on both sides with an ID not compatible with the gauge plate. After passage, the pig shall be examined and the water filtered for debris. 9.2.3 Acceptance Criteria The pig shall pass through the bore of the flexible pipe undamaged. Minor scratches and scuffs are acceptable, but dents are not. The acceptance criteria for the amount and size of debris that is allowable and a method to remove them if the criteria is exceeded shall be specified. 9.3 9.3.1 Hydrostatic Pressure Test Purpose The purpose of the hydrostatic pressure test is to demonstrate that the pipe can hold pressure above a desired level or to identify latent defects in the pipe. 9.3.2 Procedure Pressure testing involves pressurizing the bore of the pipe and recording pressure and temperature variations over time. Pressure and temperature measurement locations shall be selected to ensure correlation between the measurements. Pipe can be left on reel or inside carousel, or short sections/jumpers can be in the straight configuration. Unless otherwise specified by the purchaser, the minimum FAT pressure shall be as specified in Table 2. A higher test pressure can be either required by local codes or regulators or proposed by manufacturer on the basis of test procedure reviewed and approved by IVA. Unless otherwise specified by the purchaser, fresh water (new source or recycled), filtered to 100 μm and with a chloride content less than 50 mg/l shall be used for the test fluid. If required to protect the internal carcass material, the water shall be chemically inhibited or treated against bacteria. A suitable dye may be added to assist in leakage detection. Trapped air shall be removed from the pipe in accordance with the manufacturer’s procedures. The pressure shall be gradually increased at a rate not greater than the manufacturer’s test procedure, to a level between 100 % and 110 % (see API 17B) of the hydrostatic test pressure and held for a period of at least 2 h to allow for stabilization. This maximum hydrostatic test pressure shall not cause the allowable utilization factors of Table 8 and Table 11 to be exceeded. If necessary, the pressure shall be cycled to this pressure until stabilization is achieved. The pressure shall be considered stabilized when the pressure drop is less than 1 % in a 1 h period. Pressure shall then be increased between the nominal test pressure and the maximum hydrostatic test pressure. The timing of the hold period shall not start until the equipment and pressure-monitoring gauge have been isolated from the pressure source. SPECIFICATION FOR UNBONDED FLEXIBLE PIPE 93 The hydrostatic test pressure shall be held for a period of not less than 24 h unless a reduced period of time and corresponding acceptance criteria are agreed and justified to purchaser. During the test, pressure and temperature (ambient and internal) shall be recorded at least every 30 min. Depressurization shall be performed at a rate in accordance with the manufacturer’s test procedure. After depressurization, the end fitting areas shall be visually examined for any sign of permanent deformation or damage in both the pipe and the end fittings. If a pig has been used for filling or emptying the pipe, the cups shall be examined for damage and wear. Damage or excessive wear shall be recorded and reported to the purchaser. 9.3.3 Acceptance Criteria Pressure loss due to all possible sources of pressure fluctuation, including trapped air inside the pipe, pipe volumetric or diameter changes, external temperature fluctuations, and additional test fluid added/subtracted accompanied by resetting the clock on the hold period and pressure source/pump, shall not exceed 4 % of the pressure at the start of the 24 h period. No leakage shall be observed from the pipe during the test. No permanent deformation or damage shall be observed in the area of the end fittings. 9.4 9.4.1 Electrical Continuity and Electrical Isolation Tests Purpose The purpose of the electrical continuity and isolation tests are to ensure that the pipe cathodic protection system will be efficient and the carcass is electrically isolated from the end terminations. 9.4.2 Procedure The electrical continuity test shall be performed between the two end fittings. Electrical isolation tests shall be performed between the end fittings and the carcass when applicable. Electrical continuity and isolation measurements shall be recorded. 9.4.3 Acceptance Criteria For the electrical continuity test, the electrical resistance between the end fittings shall be less than 10 Ω/km of pipe (for short-length jumpers less than 100 m long, this electrical resistance shall be less than 1 Ω). For the electrical isolation test of rough bore pipes, the electrical resistance between the internal carcass and the end fittings shall be greater than 1 kΩ. 9.5 9.5.1 Gas-venting System Test Purpose The purpose of the gas-venting system test is to demonstrate that the gas-relief system, including valves used to relieve pressure buildup in the pipe annulus, functions properly prior to pipe delivery. For a matter of end fittings accessibility, this test might not be performed after final packing. 9.5.2 Procedure Dry air or nitrogen gas shall be pumped into one end fitting at the design pressure for the gas-relief system. Gas release shall be checked at the other end fitting, or pressure test shall be checked at each port following the procedure in 9.6.4. For smooth bore pipe, a vacuum test in accordance with 9.6.2 should be used. The procedure shall be repeated from the opposite end of the pipe. 94 API SPECIFICATION 17J All valves shall be tested for relief pressure. All valves shall relieve within the manufacturer’s specified range of relief pressure. This procedure might not be feasible for long lengths of pipe. An alternate procedure is acceptable if it can be demonstrated to satisfy the same general requirements. The procedure used shall be documented in the manufacturer’s written specification. The pressure and volume flow rate shall be measured at the outlet port. The flow rate from each valve shall meet at least the manufacturer’s specified criterion or other criterion agreed with the purchaser. The flow rate through each vent port shall be measured and recorded in the as-built documentation. If requested by the purchaser, the flow rate shall be verified, through each vent port, from one end fitting to the other and vice versa. The flow rate should be measured at the inlet port while checking for positive flow at the outlet port. 9.5.3 Acceptance Criteria The flow path shall be confirmed at all ports individually. All valves shall relieve at the manufacturer’s specified relief pressure. 9.6 9.6.1 Annulus Sealing Test Purpose The purpose of the annulus sealing test is to confirm the integrity of the external sheath and sealing/crimping of the external sheath at the end fitting. Either an annulus vacuum or pressure test can be used. This type of sealing test can only be performed for pipes that have gas-venting systems or ports integrated in the end fittings. Note that an annulus pressure test cannot be performed on a smooth bore pipe unless an anti-collapse sheath is present or there is a sufficient pressure in the bore. For flexible pipes with a designed, guaranteed intact annulus, a sealing test of the pipe annulus shall be performed after the factory hydrostatic test. The manufacturer shall have a validated test procedure. The acceptable variations (times, rates, etc.) between tests shall be specified in the procedures and shall be based on the manufacturer’s documented experience and consideration of the size, length, and other key characteristics of each pipe. 9.6.2 Procedure for Annulus Vacuum Test The annulus vent system is isolated to draw a partial vacuum in the annulus space. The annulus pressure is reduced gradually to a pressure specified by the manufacturer and approved by the purchaser, followed by measuring the initial leak-down rate (decay of vacuum over the first hour). NOTE It is recommended that the annulus pressure is not greater than 500 mbara at both ends of the annulus in FAT and load-out tests. The vacuum pump is stopped to allow the pressure to stabilize; the stabilization period shall be specified by the manufacturer and approved by the purchaser. The pressure is then held for a period; the hold period shall be specified by the manufacturer and approved by the purchaser. NOTE It is recommended that the stabilization period is a period not less than 15 min and the hold period is a period not less than 4 h. The annulus volume and associated temperature shall be measured and recorded. SPECIFICATION FOR UNBONDED FLEXIBLE PIPE 9.6.3 95 Acceptance Criteria for Annulus Vacuum Test The pressure increase in the annulus shall be specified by the manufacturer. NOTE It is recommended that the pressure increase does not exceed 30 mbara during the hold period. 9.6.4 Procedure for Annulus Pressure Test Slowly charge the vent ports with nitrogen gas to a pressure qualified and validated by manufacturer. The pressure-relief valves low setting pressure shall be communicated to purchaser. Allow the pressure in the annulus to stabilize. This should be achieved in 20 min to 30 min. The pressure is then held for a period of 1 h. The annulus volume and associated temperature shall be measured and recorded. 9.6.5 Acceptance Criteria for Annulus Pressure Test The pressure drop shall not exceed 250 mbar during the hold period and shall not drop more than 25 mbar during the final 20 min of the hold period. For pipes with an intermediate anti-collapse sheath, the anti-collapse sheath crimping seal shall be tested to demonstrate integrity and leak tightness against design external pressure, according to a procedure established by the supplier. 9.7 9.7.1 End Fitting Sealing Test General Testing to be done as directed by Table 9. This section refers to testing end fitting sealing systems only and does not include the hydrostatic pressure test of 9.3. 9.7.2 Purpose The purpose of the end fitting sealing test is to verify the integrity of the end fitting against seawater ingress that could cause annulus flooding. 9.7.3 Procedure Every sealing system in the end fitting except the internal pressure sheath sealing shall be tested and shown to be leak tight up to their design external pressure multiplied by a factor of at least 1.1. Pressure to be held for 15 min after stabilization. Additionally, all vent ports, epoxy injection ports/plugs, and sealed interfaces (e.g. between inner and outer casing) shall be factory tested to confirm the tightness at a factor of 1.1 over the design external pressure. Pressure to be held for 15 min after stabilization. All vent ports, interfaces, and sealing systems shall be leak tested with N2 or air for 15 min as per recognized international standards (e.g. ASME Boiler and Pressure Vessel Code Section VIII). If agreed with purchaser, a test with liquid may be proposed, in which case new duration and acceptance criteria shall be defined. 9.7.4 Acceptance Criteria No pressure loss greater than 3 % (per API 17D) after stabilization. 96 API SPECIFICATION 17J 10 Marking and Packaging 10.1 Marking The flexible pipe marking shall be applied to both end fittings and shall be indelible for the specified service life. As a minimum, the following markings shall be applied: a) designation of API 17J; b) serial number of pipe; c) manufacturer name or mark; d) manufacture date; e) design pressure; f) SR; g) the complete length of all flexible pipes shall be marked with a longitudinal line; h) limp stiffness direction (for avoiding corkscrewing or pigtailing during transpooling, alignment of topside jumpers or subsea connections to goosenecks); i) design water depth and minimum design water depth for which the pipe is designed for; j) permanent marking of theoretical location of buoyancy modules/ancillary components (taken at the clamp location and on either side of buoyancy module/ancillary component), to identify movement or slippage of the component along the pipe. Marking shall be made with due consideration of tolerance (fabrication/measurement) accumulation vs key datums (start point/direction). Additional markings shown in Table 31 of API 17B should also be considered. The manufacturer shall propose and provide markings on opposite sides of the pipe that denote the flexible length at a maximum spacing of 10 m for risers and pipelines. The markings shall be large enough and colored so as to be clearly visible against the pipe background under typical ROV illumination. 10.2 Packaging The flexible pipe shall be packaged in accordance with the manufacturer’s specifications. If stored on reels or carousels, the pipe shall not be subjected to a bend radius less than the SR. The end fittings and connectors should be wrapped in heavy-duty protections unless packed in crates with adequate protection. Both ends of the pipe shall be sealed. The manufacturer’s specifications shall include procedures for storage and packaging of integral components mounted on the pipe, including bend stiffeners. Storage blinds, ropes/wires, shackles, and other required handling equipment shall be identified in the packaging procedures. The manufacturer’s specifications shall include procedures for controlling suitable back tension (at all times), number of layers, and closeness of wraps for reels to be used for pipe packing, transportation, or installation in order to avoid failure modes such as pigtail, global pipe kinking, and lateral buckling of tensile armors. The packaging shall be such that the pipe is protected against all expected environmental occurrences when stored outdoors. A protective cover should be used. The flexible pipe should not protrude beyond the edges of transport reels, such that abrasive damage could occur to the pipe. In case the end fitting or ancillaries SPECIFICATION FOR UNBONDED FLEXIBLE PIPE 97 connected to the flexible pipe protrude from the transport reels, suitable protective devices shall be planned to avoid abrasive damage. If the pipe is to be installed off the reel and free flooded, the inboard end fitting shall be vented. The manufacturer shall label minimum temperature for storage and unspooling. 11 Requirements for Independent Review and Certification 11.1 General This section provides the requirements applicable to the IVA scope of work, including general requirements for the IVA and the main documents to be issued (see Figure 2) with their associated minimum scope. The manufacturer shall have an IVA assigned for the review and certification of its design, materials, and manufacturing process, and relevant information considered confidential, including: a) product concepts, including their range of use; b) design methodologies, design tools, software, and criteria as per item 11.2.3; c) materials, as per item 11.2.4; d) manufacturing processes, as per item 11.2.5; e) manufacturing plants, including specific manufacturing limitations; f) flexible pipe and prototype performances. The IVA may also be required by the purchaser to perform a project-specific review, witnessing during manufacturing, and to issue project-specific certificates (when applicable) and associated reports (see 11.3). Figure 2—Flexible Pipe Certification Scheme 11.2 Type Approval Certification Process 11.2.1 General The IVA technology certification shall be based on evidence provided by the manufacturer. This evidence may include technical literature, design analyses, test results, and track records. The range of applicability of each material, methodology, design tool, and manufacturing process shall be clearly stated by the manufacturer and reviewed by the IVA, based on such evidence. 98 API SPECIFICATION 17J During certification process, the IVA shall review all relevant packages of manufacturer’s methodologies and associated validation report, and criteria. In addition to the above, the certification shall cover, at least, the following items: a) product and flexible pipe design, including material selection and characterization, local analysis product service life analysis, and structural dimensioning for all predicted failure modes and mechanisms; b) pipe manufacturing and assembling methods, including control of processes and acquisition and treatment of the manufacturing data; c) prototype development and qualification, including evaluation of experimental data and representativeness of samples and test procedures; d) evidences of the qualification of manufacturer’s suppliers (i.e. subvendors’ quality management system) and qualification of their products, where design is considered as critical. IVA certificates (and associated reports that shall contain key information from each of these documents and reference them) shall be issued to comply with the requirements for each of the items 11.2.3 to 11.2.5 below. All certificates as per 11.2.3, 11.2.4, and 11.2.6 shall be available for review by the purchaser. The certificates shall reference all supporting evidence and IVA deliverables used to generate them, which should address the specific details of the certification process and the ranges and limits defined in the certificates. For every report related to a design methodology, manufacturing process, or material, the IVA shall include a list of the objective evidence used as a basis for the certification. The list of objective evidence shall include the reports, tests, manufacturing trials, and analyses performed by the manufacturer to calibrate or support that specific design methodology, manufacturing process, or material. In order to certify product performance and control of the manufacturing process, the IVA may also need to witness or manufacturing trials. For any failures occurring in the field known by the manufacturer or results outside of the predictions seen in the tests, the failure mode and mechanism shall be identified and notified to the IVA. If the root cause is related to the pipe itself, the design methodology, manufacturing process, or material specification related to that particular failure mode or mechanism shall undergo a new certification process. The design methodology, manufacturing process, or material specification associated with a new failure shall no longer be considered as certified for the range of application the failure was observed, until it is updated by the manufacturer and recertified by the IVA. The selected IVA shall have demonstrated expertise in the certification of design of the products, of the manufacturing methods, and of the materials used in the products. 11.2.2 Failure Mode Analysis For any extension of the certified design range, or new pipe design, the manufacturer shall perform and the IVA shall review or participate in a failure mode analysis, following an industry-recognized method such as FMECA. The failure mode analysis will serve as the basis for identifying the risks, applicable failure modes and mechanisms, and implementation of the mitigation actions to the flexible pipe and their correlation with the design methodology and tools and with the manufacturing processes. 11.2.3 Design Methodology Certification Process The IVA shall issue certificates and reports regarding the design methodology confirming the suitability and certified range of use of all manufacturer’s design methodologies and tools. SPECIFICATION FOR UNBONDED FLEXIBLE PIPE 99 The certification shall include a clear description and the evaluation of the manufacturer’s general design methodology (e.g. design flowchart, as per API 17B). The set of rules, software, and tools (including annulus prediction and its range) used for each of the steps shall be clearly identified. Design methodologies shall be considered certified for a certain range of use if the IVA has sufficient evidence that the manufacturer predictions are confirmed through a comprehensive set of tests and/or complementary analysis, taking into account the design methodology uncertainties and the capability and variations of the manufacturing processes (being reviewed as per 11.2.5), which shall be properly identified. Manufacturer shall document the evidence and the IVA should verify that the prototype test is representative and the design methodology is conservative. If more restrictive safety or utilization factors are required for any given design criteria, the limit safety factor shall be clearly stated in the design methodology certification reports. The design methodology certificates shall include: a) the applicable failure modes and mechanisms; b) the applicable tool or tools for the design against each failure mode/mechanism; c) the design criterion adopted for each failure mode/mechanism, including those defined by the manufacturer and not found in API 17J; d) the valid version of each design tool; e) the range of use of each tool for each relevant design parameter; f) the limitations of each tool; g) any key remarks or comments. The range of use shall be certified by the IVA. Annex H of API 17B presents examples of parameters for which the range of use should be certified. Other failure modes and mechanisms may be included according to the results of the failure mode analysis (11.3). 11.2.4 Material Certification Process The IVA shall certify the materials to be used in the products. The material properties shall be reviewed, and the range of use for each material shall be certified. All materials to be used in the design of critical components identified in the failure mode analysis shall be certified by the IVA. The material certification to be issued by the IVA shall include possible suppliers, the review of specifications used to purchase the raw materials from the sub-suppliers, and the quality control activities used to ensure that the properties of the materials in the final processed stage are as considered in the design and abiding to the requirements of API 17J. The models and data used to determine the long-term properties of materials shall also be assessed and certified by the IVA, including degradation curves and corrosion rates assumed in the design methodology. For each material, the certificate shall include at least the following, when applicable: a) material name, as adopted by the manufacturer; b) commercial material name, if any; c) material specification number; 100 API SPECIFICATION 17J d) range of geometrical parameters; e) range of temperature 9; f) range of pressure for nonmetallic materials; g) range of pH 9; h) range of CO2 fugacity or partial pressure 9 for which the material has been tested; i) range of H2S fugacity or partial pressure 9 for which the material has been tested; j) range of chlorides 9 for which the carcass profile has been tested; k) chemicals degradation limits (for those chemicals tested); l) possible use of the material (in which layers the material may be used); m) if the material is applicable to static and or dynamic service; n) S-N curves references with annulus conditions tested (when relevant); o) manufacturing plant and associated machine ranges. Manufacturer’s material qualification reports, containing the test history, characteristic properties, and limits of use of each material and subvendors (mill’s name for basic and processed raw material), shall be reviewed by the IVA. The tests to define the characteristic properties of materials shall consider all processes (and their variation) adopted to produce the pipe that may have any impact on the materials. For the materials to be used in the flexible pipe design, the IVA shall verify that the effects of manufacturing processes and degradation mechanisms (such as wear, corrosion, dimensional changes, creep, and aging in all layers) on the design methodologies are taken into account, unless the pipe design is documented to not suffer from such effects. 11.2.5 Manufacturing Methodology Review The IVA shall issue a manufacturing process review report describing the basic limits and constraints of the manufacturing process. The range of use for the manufacturing of each layer for each manufacturing plant shall be defined containing for instance: a) allowable range of diameters 10, b) allowable range of materials 10, c) allowable range of profiles and sizes 10 (when applicable), d) allowable range of pitch for wound layers, e) allowable range of thickness 10 of extruded polymer layers, 9 When applicable, the parameter range shall be associated to the range of other parameters that are relevant for a specific failure mechanism (e.g. CF, SSC, HIC, and SCC). 10 When applicable, the parameter range shall be associated to the range of other parameters that are relevant for determining the manufacturing capacity of the industrial plant. SPECIFICATION FOR UNBONDED FLEXIBLE PIPE f) 101 allowable range of tape thickness. The manufacturing control process shall be subjected to the review of the IVA. The monitored variables and associated tolerances, and the inspection/monitoring techniques and their range of application, shall be reviewed and registered in the report. The IVA shall verify that the manufacturing process is controlled such that the design requirements are met within the range of applicability of the design methodology. This review process shall be applied to all manufacturing plant of a given manufacturer and supported by witness of manufacturing runs. Every subprocess identified as critical during the failure mode analysis (11.2.2) within the whole manufacturing process, including the machinery, preforming, welding, heat treatment, and splicing, shall also be reviewed and have its range clearly stated in the report. The mounting process of the end fittings shall be subjected to IVA review. The range of use of each manufacturing step shall be clearly stated for each different manufacturing step, machine, or plant that was reviewed. The review of the manufacturing process shall also include the review of the standard repair procedures, coating, FAT, handling, and storage. The manufacturing process review report shall also reference the associated instructions and quality assurance documentation that was reviewed. The manufacturer shall have an implemented plan to train and periodically evaluate the end fitting mounters based on the design requirements and manufacturing tolerances (as specified in Section 5). The training and evaluation plans of the end fitting mounting personnel and the end fitting mounting process shall be documented and reviewed by the IVA. The evidence used to support the certification of the manufacturing process shall include manufacturing records and analysis through which it can be confirmed that the manufacturing processes are controlled and that the tolerances can be achieved. Additional documentation regarding qualification of special processes and the repair procedures shall be also included due to their possible influence of these processes in the pipe structural capacity. 11.2.6 Type Approval Certificate (TAC) Upon completion of the activities described in 11.2.2 to 11.2.5, a TAC and an associated report shall be issued by the IVA. In the previous version of API 17J, this certificate was referenced as the design methodology verification report. The TAC and its appendices shall reference all associated certificates and reports and include the IVA’s assessment of: a) factory location; b) unbonded pipe family 11; c) range of pipe ID; d) range of pipe maximum design pressures; e) range of pipe maximum and minimum design temperatures; 11 Reference is made to Table 2 of API 17B. 102 f) API SPECIFICATION 17J pipe application: static, dynamic, sweet and sour service; g) statement confirming that the design methodologies have been evaluated and certified through correlation tests and predicted failure modes/mechanisms, materials qualification has been confirmed, and manufacturing process have been assessed; h) certificate issuance and expiration dates; i) any outstanding issues or remarks reflecting previous or ongoing work. The TAC and its associated appendices shall also include the results 12 of basic testing as exemplified below: a) results of hydrostatic collapse test results vs pipe ID vs pipe family 12 and curvature; b) results of burst test results vs pipe ID vs pipe family 12; c) results of pipe full-scale fatigue test results (including ancillaries such as bend stiffeners, as applicable) vs pipe ID vs pressure armor type; d) results of full-scale tests executed to certify the methodology for lateral buckling prevention vs pipe ID vs test curvature range. The type approval report associated to the TAC shall reference supporting IVA documentation, which contains details of the IVA activities, and the evidence provided by the manufacturer to define the qualified ranges of the design methodologies, materials, and manufacturing processes. 11.3 Project Certification Process 11.3.1 General As an option, where required by the purchaser, the IVA may be requested to perform project-specific certification. In cases where project documentation review is requested, then the purchaser may request that the IVA supplies an IDRC, as per 11.3.2, and/or a COC, as per 11.3.3. 11.3.2 Independent Design Review Certificate (IDRC) When required by the purchaser, and for each specific project, an IDRC is issued by the designated IVA, certifying that the products are adequate to the functional and design requirements and in line with certified design methodologies. The IDRC shall clearly state that the flexible pipe proposed by the manufacturer is within the API 17J TAC ranges and adequate to the functional and design requirements of the project purchaser specifications. The IDRC shall clearly state any exceptions or limitations. As part of the project certification process, the IVA shall: a) verify the correct implementation of the certified procedures, methodologies, and tools; b) verify the material selection; 12 Results shall be associated to information on if test achieved the failure of pipe/component of interest for methodology validation. SPECIFICATION FOR UNBONDED FLEXIBLE PIPE 103 c) review any methodology and/or analysis that has not been reviewed during the type approval certification process specified in 11.2 (e.g. specific finite element analyses, system-related issues, or global analyses such as dynamic analyses, upheaval buckling analyses, clashing analyses, etc.); d) check that the API 17J requirements and design criteria are met in the flexible pipe body as well as in the end fitting and review all the documentation specified in 8.1; e) regarding the end fitting design, in addition to its mechanical strength and termination of the different flexible pipe layer (including tensile armor anchoring), detailed end fitting drawings are to be examined. Correct implementation of the polymer sheath sealing system design rule is to be checked; f) check that all the requirements particular to the purchaser’s specifications (i.e. supplementary requirements to API 17J) are met for all load cases as defined in Table 6; g) if relevant, for any design methodology or material that would not be incorporated within the TAC, review the existing validation or qualification dossier, with a particular focus on the project case; h) if relevant, witness and review any qualification activity identified during the failure mode analysis process (11.2.2), e.g. manufacturing processes of the samples for qualification tests, end fitting mounting, or specific qualification tests required by the purchaser or to bridge the gap with already qualified products; i) if relevant, perform selective independent analyses to verify critical aspects of the design and confirm some calculations results, e.g. global dynamic analysis. Any remarks or limitations shall be clearly pointed out in the IDRC. In order to close the loop and improve the overall efficiency of the certification process, an important step is to capitalize on qualification activities conducted within projects and to incorporate them into the type approval certification. 11.3.3 Certificate of Conformity (COC) When required by the purchaser, and for each specific project, a COC is issued by the designated IVA, certifying that the products are manufactured in accordance with API 17J requirements and purchaser specifications and within the TAC range. The manufacturer shall issue a manufacturing quality plan (MQP) for assessment by the IVA for review and markup to define the surveillance points. For issuance of the COC for each flexible pipe product, the IVA will: a) verify the material traceability including material certificates (e.g. Table 18) and the welders’ qualification; b) witness the fabrication of the pipe as well as its assembly with the end fittings in accordance with the MQP; c) confirm that the pipe has been manufactured in accordance with the certified fabrication procedures, work instructions, and control procedures as well as with the specific purchaser's requirements, if any; d) review the assessment of potential nonconformities together with the associated corrective actions. To this end, the manufacturer shall document by dedicated tests and/or calculations that the repairs to the flexible pipe product do not compromise its structural or long-term properties; e) if relevant, review any manufacturing aspect that would not be covered by the TAC (e.g. project-specific acceptance criteria for defects or tolerances, new procedure, new machine); f) witness any required production tests and certify the obtained results; 104 API SPECIFICATION 17J g) witness and certify that the FAT has been carried out in accordance with API 17J requirements; h) review of manufacturing databooks. Any remarks or limitations shall be clearly pointed out in the COC. In order to close the loop and improve the overall efficiency of the certification process, an important step is to capitalize on qualification activities conducted within projects and to incorporate them into the type approval certification. Annex A (informative) Purchasing Guidelines A.1 Table A.1 in this annex gives purchasing guidelines for flexible pipes. A.2 A separate form should be completed for each length of flexible pipe. A.3 The manufacturer should specify in the design premise the values assumed for all parameters in Table A.1 not specified by the purchaser. Table A.1—Flexible Pipe Purchasing Guidelines General Information Client: Client reference: Project: Phone: Location: Fax: Purchaser’s technical contact: Enquiry date: Conformance to API 17J required? Yes No Required response date: General Design Parameters Internal diameter (m): Maximum axial load (kN): Length required (m): Maximum effective tension (kN): Tolerance required on length (m ± m): Torsional balance requirement (°/m or rad/m): Pipe structural requirements (MBR, bend stiffness): Compression strength requirement (kN): Linear mass requirements (kg/m) in air empty: Installation: External protection requirements (external carcass): Permanent operation: Design load case probabilities: Abnormal operation: Service life (years): Specification of permanent and abnormal load cases, including accidental loads, and definition of load combinations to be used in the design: Annulus class: Classes of annulus (see Table 9) for riser sections and for flowlines and with details on required vent connections for annulus inspection and monitoring during operation: NOTE °C = degree Centigrade; °F = degree Fahrenheit; g = gram; K = Kelvin; kg = kilogram; kJ = kilojoule; kN = kilonewton; KOH = potassium hydroxide; kPa = kilopascal; l = liter; m = meter; MBR = minimum bend radius; mg = milligram; MPa = megapascal; ppm = parts per million; TAN = titrated acid number; TFL = through flowline; W = Watt. 105 106 API SPECIFICATION 17J Table A.1—Flexible Pipe Purchasing Guidelines (Continued) Internal Fluid Parameters General Fluid description (oil, gas, water): Flow regime description (single, phase, slug): Service definition (sweet/sour): Fluid heat capacity (kJ/kg/°C): Slug parameters: density (kg/m3), frequency (1/min), length [m (ft)] and distribution over service life. Flow Rate Parameters Viscosity (Pa • s): Fluid density (kg/m3): Flow rate (m3/day): Minimum inlet pressure (MPa): Required outlet pressure (MPa): Pressures Design pressure [MPa (psi)]: Operating pressure profile during the service life [MPa (psi)]: Max./Min. operating pressure and/or [MPa (psi)]: Incidental pressure [MPa (psi)]: , duration: Vacuum conditions [MPa (psi)]: Number and range of pressure cycles expected during the specified service life: Maximum operational depressurization and pressurization rates: Temperatures Design minimum temperature (°C): Operating inlet temperature (°C): Design maximum temperature (°C): Number and range of temperature cycles expected during the specified service life: Incidental temperature (°C): , duration: Upset temperature and cycles (°C): Fluid Compositional Data NaCl content (weight percent of water): Chlorides content [mg/l]: Gas-oil ratio (m3/m3): Water cut (volume percent): TAN (mg KOH/g): pH of aqueous phase: Alcohols? Yes No Inhibitors (scale, paraffin)? Yes No Aromatic components? Yes No Injected chemicals? Yes No Corrosive agents? Yes No Solids, precipitates, etc.? Yes No ANSI/NACE MR0175/ISO 15156 to apply? Yes H2S partial pressure (bar): No CO2 partial pressure (bar): FLIP (required for gas duty with LVF < 1 %) FLIP screening required (yes/no): Reflection coefficients (inlet and outlet): If available, attach details of full fluid compositional data and expected variation over the service life. Also, attach details of any aromatic components, corrosive agents, inhibitors, alcohols, solids, or injected chemicals in the fluid composition (include pressure and temperature of injection, concentrations of dissolved oxygen, and pH of aqueous phase, if applicable, with all injected fluids). Purchaser to be as detailed as possible about what pressures, temperatures, locations, combination, and conditions are associated with any concentrations or other properties. FLIP section only applicable when FLIP screening analysis is marked “yes.” Normal operating conditions following 4.6.1.15. NOTE °C = degree Centigrade; °F = degree Fahrenheit; g = gram; K = Kelvin; kg = kilogram; kJ = kilojoule; kN = kilonewton; KOH = potassium hydroxide; kPa = kilopascal; l = liter; m = meter; MBR = minimum bend radius; mg = milligram; MPa = megapascal; ppm = parts per million; TAN = titrated acid number; TFL = through flowline; W = Watt. SPECIFICATION FOR UNBONDED FLEXIBLE PIPE 107 Table A.1—Flexible Pipe Purchasing Guidelines (Continued) External Environment—Static Loads Water Depths Design water depth (m): Maximum tidal variation (m): Minimum tidal variation (m): Attach details of water depth variation over flexible pipe route. Soil Data Soil description (clay, sand): Angle of internal friction (degrees), roughness, grain size, soil stability, liquefaction, submerged/dry unit weight: Soil shear strength (kPa): Lateral friction coefficient: Seabed scour/sand waves occur? If available, attach seabed profile. Yes No Longitudinal friction coefficient: Air Temperatures Minimum temperature (°C): Minimum storage/transport/installation temperature (°C): Maximum temperature (°C): Maximum storage/transport/installation temperature (°C): Seawater Data Density: pH value: Maximum surface temperature (°C): Maximum seabed temperature (°C): Minimum surface temperature (°C): Minimum seabed temperature (°C): Upheaval Buckling Data Soil stiffness and strength in lateral downward and upward direction considering the effect of trenching and backfill if relevant. Seabed friction, axial and lateral both maximum and minimum. Installation, testing, trenching, and protection sequence with corresponding temperature and pressure. (Required for proper upheaval buckling and tie-in design.) Capacity of tie-in porches on subsea terminations. Other Marine growth to be considered? Sunlight exposure? Yes No Yes No Yes No If yes, attach details. Ice effects to be considered? If yes, attach details. Current data attached? Yes No Attached current data should be given as a function of water depth, direction, and return period. External Environment—Dynamic Loads Wave data attached? Yes No Attached wave data should be given in terms of significant wave, maximum wave, equivalent periods, spreading functions, scatter diagrams, as a function of direction and return period. For irregular seas, the wave spectrum data should be specified. Wind data attached? Yes No Attached wind data should be given in terms of maximum 3-s, 1-min, 10-min, and 1-h wind speeds, as a function of direction, height above water level, and return period. NOTE °C = degree Centigrade; °F = degree Fahrenheit; g = gram; K = Kelvin; kg = kilogram; kJ = kilojoule; kN = kilonewton; KOH = potassium hydroxide; kPa = kilopascal; l = liter; m = meter; MBR = minimum bend radius; mg = milligram; MPa = megapascal; ppm = parts per million; TAN = titrated acid number; TFL = through flowline; W = Watt. 108 API SPECIFICATION 17J Table A.1—Flexible Pipe Purchasing Guidelines (Continued) General System Requirements General System description (flowline, riser, jumper, subsea, topsides): Cathodic protection system required? Application definition (static, dynamic): Electrical continuity required? Yes No Pipe bore description (rough, smooth): End fitting coatings required? Yes No Corrosion protection requirements. External coating description: Corrosion protection required? Yes No Yes No Internal coating description: If available, allowable electrical resistance, protection voltage, current source, and current density should be specified. Purchaser may request additional design factor for buried end terminations as inspection/measurement is not feasible for the entire service life. Annulus required classification (as per Table 9)? Class 0 Class 1 Class 2a Class 2b Class 3 Thermal Insulation Thermal insulation required? Yes No Required insulation U-value (W/m2K): Insulation U-value should be based on pipe ID and be for the pipe alone. Specify any allowances that can be made for external effects such as soil. Required outlet temperature (°C): Connector Attach welding specification seal type and sizes, and responsibility for supply and mounting of components. Lower connector type (flange, pipe): Upper connector type (flange, pipe): Gas Venting Gas-venting required? Yes No System components (valves, burst disks): Venting location restrictions? Gas-monitoring system? Allowable gas permeation rate (l/m/day): Other Fire resistance required? Specify (Lloyds/DNV/API 16C): Yes No Interface definitions/specifications (see 4.6.1.10): Pigging, TFL, workover, etc., required? Yes No Exothermal chemical reaction cleaning required? Yes No Piggyback required? Inspection condition monitoring required? Yes No If yes, attach details. Yes No If yes, give details of requirements. Pressure and tensile armor weld location restrictions? Yes No NOTE °C = degree Centigrade; °F = degree Fahrenheit; g = gram; K = Kelvin; kg = kilogram; kJ = kilojoule; kN = kilonewton; KOH = potassium hydroxide; kPa = kilopascal; l = liter; m = meter; MBR = minimum bend radius; mg = milligram; MPa = megapascal; ppm = parts per million; TAN = titrated acid number; TFL = through flowline; W = Watt. SPECIFICATION FOR UNBONDED FLEXIBLE PIPE 109 Table A.1—Flexible Pipe Purchasing Guidelines (Continued) Flowline Parameters General Flowline routing description attached? Yes No Guides and supports (I-tubes, J-tubes): Load cases attached? Yes No Required pipe attachments (bend restrictors, clamps): Attach drawings of all items. On-bottom stability to be checked? Yes No Crossover requirements? Yes No Upheaval Buckling Upheaval buckling to be checked? Yes No Allowable bend radius (m): Required minimum soil coverage (m): Load cases attached? Yes No Protection Requirements Impact resistance to accidental loads? Yes No Mattresses? Yes No Trenching? Yes No Other? Yes No Rock dumping? Yes No Attach details of specified protection system(s), including general arrangement drawings, possible accidental occurrences (trawl boards, dropped objects, anchors, and so on), design impact loads. Riser Parameters General Riser configuration (lazy-S, steep wave): Riser lower connection description (seabed, vessel): Attach description of riser configuration and general arrangement drawing(s) of all relevant details. Required pipe attachments (bend stiffeners, buoys): Attach drawings of all items. Riser upper connection description (platform, tanker): Interference Interference/clashing check required? Yes No Attach details of all possible interface areas, including other risers, mooring lines, platform columns, vessel pontoons, tanker heel, and so forth, and specify allowable interferences/clashing. Vessel Motion Data Vessel motion data attached? Yes No Attached vessel motion data should be specified in terms of the following for the relevant loading conditions. Attached data should include a general layout drawing, showing vessel heading, North point, riser(s) in plan, and mooring lines. — Vessel static and dynamic offsets for all conditions. — Vessel data, dimensions, drafts, etc. — Vessel first- and second-order motions, in terms of heave, surge, sway, yaw, roll, and pitch. — Vessel motion phase data and specification. — Reference point for motions. — Mooring system design, including line properties and anchor locations. — Position tolerances. 110 API SPECIFICATION 17J Table A.1—Flexible Pipe Purchasing Guidelines (Continued) Additional Requirements Materials required in addition to API 17J? Yes No Yes No If yes, specify details. Manufacturing required in addition to API 17J? If yes, specify details. Calculation of axial carcass retention capacity is required? Yes No If yes, is measurement of pitch at first 1 m of carcass in end fitting required? Yes No Selection of PSL category for 7.9 (default is PSL 2 to 3)? Yes No Yes No Yes No Yes No Yes No If yes, specify details. FAT required in addition to API 17J? If yes, specify details. Markings required in addition to API 17J? If yes, specify details. Prototype tests required? If yes, specify details. Is external sheath sealing test per 9.6 required for flowlines? If yes, specify which flowlines are to be tested and what documentation is required in 8.8 f). Additional national authority/government regulations? Yes No Yes No Yes No If yes, specify details. Purchaser inspection required? If yes, specify details. General requirements in addition to API 17J? If yes, specify details. NOTE 1 °C = degree Centigrade; °F = degree Fahrenheit; g = gram; K = Kelvin; kg = kilogram; kJ = kilojoule; kN = kilonewton; KOH = potassium hydroxide; kPa = kilopascal; l = liter; m = meter; MBR = minimum bend radius; mg = milligram; MPa = megapascal; ppm = parts per million; TAN = titrated acid number; TFL = through flowline; W = Watt. NOTE 2 “ppm” is a deprecated unit. SPECIFICATION FOR UNBONDED FLEXIBLE PIPE 111 Table A.1—Flexible Pipe Purchasing Guidelines (Continued) Delivery, Installation, Retrieval, and Maintenance Requirements Delivery requirements: Shipping, packing, and storage (and wet storage if applicable) requirements: Documentation requirements: Purchaser should specify if a separate installation manual is required. Installation Requirements Method: Vessel: General: Where relevant, the purchaser should specify any requirements for season, environment, vessel limitations, restrictions due to conflicting activities, and installation scope (including trenching, burial, testing, inspection, surveying, and documentation). Installation Design Criteria Equipment bend radius (m): Tensioner crush loads (kN): Installation/lifting device requirements: Transport reel used for installation? Yes No Pipe internal fluid at delivery (empty, water filled): Seawater flooding requirements (exposure time)? Yes No Where relevant, the purchaser should specify details such as length of tensioners, shape of tensioner shoes, number of belts, diameter of wheels, reels, ramp angles, and surface shape. Installation test requirements: Installation vessel motions and offsets attached? Yes No Attached details should, in general, reflect data requirements in vessel motion data requirements listed under riser parameters (above). Retrieval/Reuse Number of foreseen installation/retrieval operations: Recovery/reuse requirements: Pipe retrieval rate: Maintenance Maintenance required? Yes No If yes, specify details. NOTE °C = degree Centigrade; °F = degree Fahrenheit; g = gram; K = Kelvin; kg = kilogram; kJ = kilojoule; kN = kilonewton; KOH = potassium hydroxide; kPa = kilopascal; l = liter; m = meter; MBR = minimum bend radius; mg = milligram; MPa = megapascal; ppm = parts per million; TAN = titrated acid number; TFL = through flowline; W = Watt. Annex B (informative) Flexible Pipe Datasheet B.1 Table B.1 in this annex gives guidelines the minimum data to be provided on a flexible pipe datasheet. B.2 In addition, the manufacturer should also include in the datasheet an isometric schematic of the pipe cross section clearly showing the layer-by-layer construction. Table B.1—Flexible Pipe Datasheet Minimum Requirements General Information Client: Project: Bore fluid: Water depth (m, ft): Inner diameter (mm, in.): Outer diameter (mm, in.): Design pressure (MPa, psi): Design temperature (°C, °F): Operating pressure (MPa, psi): Operating temperature (°C, °F): Cross Section Layer-by-Layer Description (1) (2) Layer Type Layer Material UTS (MPa, ksi) Structural Capacity (MPa, ksi) Mass (kg/m, lbf/ft) ID (mm, in.) T (mm, in.) Theoretical Pipe Properties Internal volume (l/m, cf/ft): External volume (l/m, cf/ft): Weight in air empty (kg/m, lbf/ft): Weight in air full of seawater (kg/m, lbf/ft): Weight in seawater empty (kg/m, lbf/ft): Weight in seawater full of seawater (kg/m, lbf/ft): Specific gravity in seawater empty (–): Specific gravity in seawater full of seawater (–): MBR storage (m, ft): MBR operating (m, ft): Burst pressure (MPa, psi): Collapse pressure (MPa, psi): Damaging pull (kN, lbf): Permissible axial compression (kN, lbf): Bending stiffness (kN-m2, lbf-ft2): Axial stiffness @ 20 °C (kN, kip): In tension: In compression: Torsional stiffness @ 20 °C (KNm2/deg, kip.ft2/deg): Stiff direction: Limp direction: Overall heat transfer coefficient (w/m2K, Btu/hft2°F): Thermal exchange coefficient (w/mK, Btu/hft°F): NOTE 1 UTS = ultimate tensile strength; ID = diameter of inner surface of the layer; t = layer thickness. Manufacturer to specify the temperature at which the properties are stated. NOTE 2 Extruded layers sealed in end fitting shall be identified by "Sealed at end fitting.” 112 Bibliography [1] API Specification Q1, Quality Management System Requirements for Organizations Providing Products for the Petroleum and Natural Gas Industry [2] API Specification 16C, Choke and Kill Equipment [3] API Recommended Practice 17A, Design and Operation of Subsea Production Systems―General Requirements and Recommendations [4] API Recommended Practice 17B, Recommended Practice for Flexible Pipe, 6th Edition [5] API Recommended Practice 17C, Recommended Practice on TFL (Through Flowline) Systems [6] API Specification 17E, Specification for Subsea Umbilicals [7] API Specification 17K, Specification for Bonded Flexible Pipe [8] API Specification 17L1, Specification for Ancillary Equipment for Flexible Pipes and Subsea Umbilicals [9] API Recommended Practice 17L2, Recommended Practice for Ancillary Equipment for Flexible Pipes and Subsea Umbilicals [10] API Technical Report 17TR2, The Aging of PA-11 Inflexible Pipes [11] API Standard 1104, Welding of Pipelines and Related Facilities [12] ASME Boiler and Pressure Vessel Code Section VIII [13] ASTM A388/A388M 13, Standard Practice for Ultrasonic Examination of Steel Forgings [14] ASTM C335/C335M, Standard Test Method for Steady-State Heat Transfer Properties of Pipe Insulation [15] ASTM D570, Standard Test Method for Water Absorption of Plastics [16] ASTM D624, Standard Test Method for Tear Strength of Conventional Vulcanized Rubber and Thermoplastic Elastomers [17] ASTM D746, Standard Test Method for Brittleness Temperature of Plastics and Elastomers by Impact [18] ASTM D790, Standard Test Methods for Flexural Properties of Unreinforced and Reinforced Plastics and Electrical Insulating Materials [19] ASTM D1525, Standard Test Method for Vicat Softening Temperature of Plastics [20] ASTM D1693, Standard Test Method for Environmental Stress-Cracking of Ethylene Plastics [21] ASTM D2240, Standard Test Method for Rubber Property—Durometer Hardness [22] ASTM D2583, Standard Test Method for Indentation Hardness of Rigid Plastics by Means of a Barcol Impressor [23] ASTM D2857, Standard Practice for Dilute Solution Viscosity of Polymers 13 ASTM International, 100 Barr Harbor Drive, West Conshohocken, PA 19428, www.astm.org. 113 114 API SPECIFICATION 17J [24] ASTM E94/E94M, Standard Guide for Radiographic Examination Using Industrial Radiographic Film [25] ASTM E165/E165M, Standard Practice for Liquid Penetrant Testing for General Industry [26] ASTM E127, Standard Practice for Fabrication and Control of Flat Bottomed Hole Ultrasonic Standard Reference Blocks [27] ASTM E709, Standard Guide for Magnetic Particle Testing [28] ASTM E739, Standard Guide for Statistical Analysis of Linear or Linearized Stress-Life (S-N) and Strain-Life (e-N) Fatigue Data [29] BS EN ISO 15607:2003 14, Specification and qualification of welding procedures for metallic materials— General rules [30] BS EN ISO 15609, Specification and qualification of welding procedures for metallic materials—Welding procedure specification [31] DNV-RP-B401 15, Cathodic Protection Design [32] DNV-RP-F103, Cathodic Protection of Submarine Pipelines [33] DNV-RP-F109, On-Bottom Stability Design of Submarine Pipelines, Cables and Umbilicals [34] DNV-ST-N001, Marine operations and marine warranty [35] ISO 62 16, Plastics—Determination of water absorption [36] ISO 75-1, Plastics—Determination of temperature of deflection under load—Part 1: General test method [37] ISO 75-2, Plastics—Determination of temperature of deflection under load—Part 2: Plastics and ebonite [38] ISO 180, Plastics—Determination of Izod impact strength [39] ISO 306, Plastics—Thermoplastic materials—Determination of Vicat softening temperature (VST) [40] ISO 868, Plastics and ebonite—Determination of indentation hardness by means of a durometer (Shore hardness) [41] ISO 974, Plastics—Determination of the brittleness temperature by impact [42] ISO 2556:1974, Plastics—Determination of the gas transmission rate of films and thin sheets under atmospheric pressure—Manometric method [43] ISO 8692, Water quality—Fresh water algal growth inhibition test with unicellular green algae [44] ISO 16120-1, Non-alloy steel wire rod for conversion to wire—Part 1: General requirements 14 British Standards Institution, 389 Chiswick High Road, London W4 4AL, United Kingdom, www.bsigroup.com. DNV, Veritasveien 1, 1363 Hovik, Norway, www.dnv.com. 16 International Organization for Standardization, Chemin de Blandonnet 8, CP 401, 1214 Vernier, Geneva, Switzerland, www.iso.org. 15 SPECIFICATION FOR UNBONDED FLEXIBLE PIPE 115 [45] ISO 15589-2, Oil and gas industries including lower carbon energy—Cathodic protection of pipeline transportation systems—Part 2: Offshore pipelines [46] SINTEF/4Subsea JIP, Handbook on Design and Operation of Flexible Pipes, April 2014 200 Massachusetts Avenue, NW Suite 1100 Washington, DC 20001-5571 USA 202-682-8000 Phone Orders: Fax Orders: 1-800-854-7179 (Toll-free in the U.S. and Canada) 303-397-7956 (Local and International) 303-397-2740 Information about API publications, programs and services is available on the web at www.api.org. Product No. G17J05
0
You can add this document to your study collection(s)
Sign in Available only to authorized usersYou can add this document to your saved list
Sign in Available only to authorized users(For complaints, use another form )