Electric Baseboard, boiler,
furnace and oil furnace
Heating
January 2025 by
Moe BaBin
1. How does a baseboard heater transfer heat?
a. By natural convection.
b. By natural conduction.
A.
c. By radiation absorption.
d. By touch.
2.
3.
What is heat considered to be?
a. A source of electricity
b. A form of energy
c. Temperature
d. Thermal pressure
B.
What is temperature considered to be
a. A source of electricity
b. A form of energy
D.
c. Temperature
d. Thermal pressure
4.
Approximately how many Btu/hr of heat will a 1500-watt heater
produce at its rated voltage of 240 volts
a. 6.25btu/h
b. 5100btu/h
1.5Kw x 3415.179 = 5122 = B.
c. 36000btu/h
d. 1500btu/h
5.
How much current will a 1750-watt heater draw from a 220 volt
source?
a. 5 A
b. 10 A
1750/220 = 7.954 A = D.
c. 0.125 A
d. 7.95 A
6.
How much resistance would a 2500-watt, 240 volt heater have?
a. 10.4 ohms
b. 0.096 ohms
240^2/2500 = 23.04 = C.
c. 23 ohms
d. 60 ohms
7.
In most cases, what can a line voltage thermostat of a baseboard
heater be connected in series with?
a. The primary coil of the relay
b. The load side of the relay
C.
c. The heater
d. Water heater
8.
What does heat anticipation mean.
a. Closing the thermostat before the heat is required
b. Energizing the heater faster than normal
D.
c. Overheating the room so that the heat will remain longer
d. Opening the thermostat before it is really satisfied by the heat in
the room
9.
What demand factor is used on 18kw of heat?
a. 18kw
b. 17kw
first 10Kw at 100%
c. 16kw
8Kw x 75% = 6Kw
10 + 6 = 16kw = C.
d. 14.4kw
10.
How many watts is allowed on a heat circuit with a 20 amp
breaker at 220v?
a. 3840w
b. 3520w
20 x 80% = 16A x 220V = 3520W
c. 3340w
= B.
d. 3150w
11.
What is the maximum size of an overcurrent device that can be
used in a branch circuit supplying two or more heating fixtures in a
residential occupancy?
a. 15 amps
b. 20 amps
62-114 2)
c. 30amps
C.
d. 40 amps
12.
How is the overheating protection of an electric baseboard
heater provided?
a. By a thermal cut out.
b. With a bi metallic stripe
D.
c. Circuit breaker
d. By a thermal linear cut out
13.
What is the RSI value of R60 insolation?
a. RSI OF 9
b. RSI OF 10.5
60 x 5.678 = 10.5 = B.
c. RSI OF 11.5
d. RSI OF 9.5
14.
How many watts are allowed on a 20 amp breaker at a voltage
of 240 volts?
a. 3840w
16A x 240v = 3840W = A.
b. 3520w
c. 3340w
d. 3750w
15.
What is the control voltage for most of electric furnaces, roof
top hvac unit and ac unites?
a. 24v ac
b. 24v dc
A.
c. 120v ac
d. 12v dc
16.
Why are most oil furnaces use R90 armored cable. BX. For
installation?
a. Because of heat rated
D.
b. Looks nice!!!
c. Because of the metal duck work
d. Mechanical protection.
17.
In an oil fired boiler or hot air furnace, what detects the flame?
a. Peep hole
b. Fan switch
D.
c. thermostat
d. Cad cell
18.
In an oil, wood, gas fired hot air furnace, what controls the air
circulating fan?
a. Fan controller
A.
b. Zone valve
c. End switch
d. Combination fan/high limit switch
19.
a.
b.
c.
d.
What does a thermocouple do in a gas furnace?
it generates a voltage in the presents of a flame
It generates a flame in the presents of voltage
It generates a voltage to the thermostat
It generates a voltage to start the fan
A.
20.
In an electric hydronic heating system, what control the
temperature of the heating system.
a. Low voltage thermostat.
D.
b. Zone valve.
c. Fixed aquastat.
d. Aquastat
21.
In an electric hot water boiler, what controls the high
temperature limit?
a. Aquastat.
B.
b. Fixed aquastat.
c. Zone valve.
d. Low voltage thermostat.
22.
In an electric water boiler, hydronic system. What controls the
zone valve to open and close?
a. Aquastat
b. Fixed aquastat
D.
c. Zone valve end switch.
d. Low voltage thermostat.
23.
In an electric water boiler, hydronic system, how does the
circulating pump turn on and off?
a. Aquastat
b. Fixed aquastat
D.
c. Zone valve end switch
d. Circulating pump relay.
24.
In an electric/oil/gas water boiler, what controls the circulating
pump relay?
a. Aquastat
b. Fixed aquastat.
A.
c. Zone valve end switch
d. Low voltage thermostat.
25.
In a low voltage thermostat, what device prevents the
temperature to over shoot and have a efficiency effect?
a. Differential setting.
b. Anticipator.
B.
c. 24 v system.
d. Sequencers.
26.
In an electric furnace, what prevents and protects a heating
element for overheating do to low to no air flow?
a. A magnetic force field.
b. A thermal cut out
D.
c. A thermal cut in
d. A thermal linear cut out.
27.
In an electric hot air /air condition furnace, hvac. What type of
thermostat would be recommended.
a. A dual zoned thermostat
B.
b. A dual heat and cooling thermostat.
c. A 2 wire thermostat.
d. A line voltage thermostat.
28.
In a mini split type of system, heating and cooling. What is
needed to switch from heat to colling and colling to heat?
a. a four-way mixing valve
b. a four-way directional valve.
B.
c. A dual mixing valve
d. A dual directional valve.
29.
If you have a 2000w electric baseboard heater rated at 240
volts. What would be the new wattage at 208 volts?
a. 2001 w
b. 1751 w
C.
c. 1501 w
d. 1251 w
30.
What is a forced air heather thermostat generally rated for?
a. Lightning strikes.
b. 20 A.
c. Inductive
C.
d. Capacitive
31.
An electronic thermostat, how do they control the voltage?
a. Diode
b. Zener
D.
c. IGBT
d. Triac