https://africanjournalofbiomedicalresearch.com/index.php/AJBR Afr. J. Biomed. Res. Vol. 27 (6s) (December 2024); 971- 980 Research Article Biomedical Waste Management in India: A Review Kunal A Majmudar1*, Krunal Shah2, Ankur Gheewala3, Jignesh Joshi4 1* Assistant Professor, Department of Environmental Science & Technology, UPL University of Sustainable Technology, kunal.srict@gmail.com 2 Assistant Professor, Department of Electrical Engineering, UPL University of Sustainable Technology, krunalshah5390@yahoo.com 3 Assistant Professor, Department of Electrical Engineering, UPL University of Sustainable Technology, ankur.srict@gmail.com 4 Assistant Professor, Department of Electrical Engineering, UPL University of Sustainable Technology, nirma.jignesh@gmail.com Abstract: Everyone who supports and finances health care operations has a social and legal obligation to manage biological waste (BMW) in a safe and sustainable manner. Both a cleaner environment and human health depend on effective BMW management (BMWM). The new 2016 BMWM regulations, practical issues with their successful application, the main flaw in traditional methods, and the newest environmentally friendly BMW disposal ways are all covered in this article. In order to alter the dynamics of BMW disposal and treatment in India, the new regulations are intended to enhance the processes of segregation, transportation, and disposal while reducing environmental contamination. A collective effort involving dedicated government funding and infrastructure development, committed healthcare personnel and facilities, ongoing oversight of BMW operations, strict legislation, and robust regulatory agencies is necessary for the successful disposal of BMWM. Waste minimization and source segregation are the cornerstones of BMWM. Additionally, for a cleaner and greener environment, a lot of research and development must go into creating environmentally acceptable medical devices and BMW disposal systems. Keywords: Biomedical Waste, 2016 Changes in BMW rules, India *Author Correspondence Email: kunal.srict@gmail.com Received - 27/10/2024 Acceptance - 03/11/2024 DOI: https://doi.org/10.53555/AJBR.v27i6S.7660 © 2024 The Author(s). This article has been published under the terms of Creative Commons Attribution-Noncommercial 4.0 International License (CC BY-NC 4.0), which permits noncommercial unrestricted use, distribution, and reproduction in any medium, provided that the following statement is provided. “This article has been published in the African Journal of Biomedical Research” Introduction: Any waste generated during the feasible. Thus, the several BMW disposal techniques are diagnosis, treatment, or vaccination of human or animal as follows: prevent, reduce, reuse, recycle, recover, treat, subjects involved in related research, or during the and finally discard, in order of their desirability. manufacture or testing of biological agents, or at health Therefore, rather than using the "end of pipe approach," camps, is referred to as biomedical waste (BMW). It uses the waste should be addressed at its source. Any facility the cradle to grave approach, which includes treating, that handles the treatment, disposal, or processes related characterizing, quantifying, separating, storing, and to these activities is referred to as a BMW treatment and transporting BMW. The three Rs—reduce, recycle, and disposal facility .[1] The remaining 75% to 95% of BMW reuse—are the cornerstones of an effective BMW is nonhazardous, with only 10% to 25% being approach. Instead of disposing of waste, the finest BMW hazardous. The hazardous portion of the waste poses a management (BMWM) techniques try to prevent waste risk to the general public and healthcare professionals from being generated or recover as much waste as who handle, process, and dispose of waste on a physical, 971 Afr. J. Biomed. Res. Vol. 27, No.6s (December) 2024 Kunal A Majmudar et al. Biomedical Waste Management in India: A Review chemical, and/or microbiological level.[2] During a June 2007 World Health Organization (WHO) meeting in Geneva, fundamental guidelines for managing healthcare waste in a safe and sustainable manner were established. It was emphasized that the negative impacts of health care waste on people and the environment might be lessened with the proper allocation of funds and total dedication. The expense of appropriate management of BMW should be shared by all parties involved in funding and supporting health care activities since they have a moral and legal obligation to safeguard others' safety. Additionally, it is the manufacturer's responsibility to create environmentally friendly medical devices so that they can be disposed of safely. WHO reaffirmed the need for the government to set aside funds for the development, upkeep, and support of an effective health care waste management system? Among these are innovative and creative techniques and tools to lessen the volume and toxicity of medical waste. Nongovernmental organizations ought to implement initiatives and activities that support this incentive[3]. The WHO guide on the safe management of waste from health-care operations, sometimes known as "The Blue Book," was originally published in 1999. Newer procedures for the safe disposal of BMWs, as well as new environmental pollution control measures and detection tools, are included in the 2014 second edition of "The Blue Book." The second edition also included additional issues such emerging pandemics, drugresistant microorganisms, climate change, and healthcare waste management in emergencies.[1] Table 1: Biomedical waste classification – categories, treatment, processing, and disposal options Category Color and type of bag to be used Type of Waste Treatment and disposal options Human anatomical waste Incineration or plasma pyrolysis or deep burial Animal anatomical waste Incineration or plasma pyrolysis or deep burial. In the absence of above facilities, autoclaving or microwave/hydroclaving followed by shredding /mutilation/combination of sterilization and shredding. Treated waste to be sent for energy recovery. Expired cytotoxic drugs and items contaminated with cytotoxic drugs to be returned back to the manufacturer or Supplier for incineration at temperature >1200° C or to CBMWTF or hazardous waste treatment, storage, and disposal facility for incineration at >1200° C or encapsulation or plasma pyrolysis at 1200° C Disposed of by incineration or plasma pyrolysis or encapsulation in hazardous waste treatment, storage, and disposal facility Soiled waste Yellow‑colored nonchlorinated plastic bags Expired or medicines discarded Yellow Chemical waste Chemical Liquid Waste Discarded linen, mattresses beddings contaminated with blood or body fluids Microbiology, biotechnology, and other clinical laboratory waste waste Separate collection system leading to effluent treatment system Nonchlorinated yellow plastic bags or suitable packing material Autoclave safe plastic bags or containers Red‑colored nonchlorinated plastic bags containers Red Contaminated (recyclable) White (translucent) Waste sharps including metals Puncture proof, leak proof, tamper proof containers Blue Glassware, Metallica body implants Cardboard boxes with blue‑colored marking or After resource recovery, the chemical liquid waste shall be pretreated before mixing with other waste forms Nonchlorinated chemical disinfection followed by incineration or plasma pyrolysis or for energy recovery Pretreat to sterilize with nonchlorinated chemicals on‑site as NACO or WHO guidelines, thereafter for incineration Autoclaving or microwaving/hydroclaving followed by shredding or mutilation or combination of sterilization and shredding. Treated waste to be sent to registered recyclers or for energy recovery or plastics to diesel or fuel oil or for road making Autoclaving or dry heat sterilization followed by shredding or mutilation or encapsulation in metal container or cement concrete; combination of shredding cum autoclaving and sent for final disposal to iron foundries Disinfection or through autoclaving or microwaving or hydroclaving and then sent for recycling AIDS = Acquired immunodeficiency syndrome, NACO = National AIDS Control Organization, WHO = World Health Organization, CBMWTF = Common bio‑medical waste treatment and disposal facility 972 Afr. J. Biomed. Res. Vol. 27, No.6s (December) 2024 Kunal A Majmudar et al. Biomedical Waste Management in India: A Review Conventions and International Agreements: When creating waste management policies, three international accords and conventions should be kept in mind because they are very relevant to BMWM, environmental protection, and its sustainable development. These are the Minamata Convention on Mercury, the Basel Convention on Hazardous Waste, and the Stockholm Convention on Persistent Organic Pollutants (POPs). The most comprehensive international environmental pact on hazardous and other wastes is the Basel Convention on Hazardous Waste. Its goals are to safeguard the environment and public health from the negative impacts of the production, handling, and disposal of hazardous wastes, particularly clinical wastes from medical treatment in hospitals, clinics, and health facilities. It has 170 member nations[4]. The Stockholm Convention on POPs, sometimes known as the Stockholm Convention, is an international agreement to safeguard the environment and public BMW 1998 Application health from POPs, which include furans and dioxins. POPs are harmful substances that build up and harm living things' adipose tissue. Incinerators of medical waste and other combustion processes produce these compounds. In 2006, the interim advice on best environmental practices (BEF) and guidelines on best available techniques were published. It addresses BEP through training, appropriate collection and transportation, resource recovery and recycling, source reduction, and segregation.[5] A global agreement known as the Minamata Convention on Mercury aims to shield the environment and human health from the harmful effects of mercury. The first new international agreement on environment and health was signed by more than 90 countries in Japan on October 10, 2014. Under this accord, several medical devices, such as blood pressure monitors and thermometers that contain mercury, will be phased out of use in health care services.[6] Table 2: Difference between biomedical waste rules 1998 and 2016 BMWM Rules, 2016 These camps and such healthcare‑related activities not covered under BMW 1998 rules. Duties of Occupier Pretreatment of the laboratory waste, blood bags, etc. was not required. Use of chlorinated plastic bags, gloves, and blood bags was mentioned Liquid waste not to be separated at source and ETP is not mandatory Training and immunization not compulsory No barcoding system was in place Reporting of accidents not specified and mentioned Duties of the operator of a CBMWTF No such recommendation were in place No such records were maintained No such records were maintained The real aim of the rules have been expanded to include vaccination camps,blood donation camps, surgical camps, or any other health care activity. Pretreatment of the laboratory waste, microbiological waste, blood samples, and blood bags Phase‑out the use of chlorinated plastic bags, gloves, and blood bags within 2 years Liquid waste to be separated at source by pretreatment and ETP is required Provide training to all HCWs in BMW rules and handling and immunize all HCWs against hepatitis B and tetanus Establish a bar code system for bags or containers containing BMW for disposal Report all major accidents To establish barcoding and GPS of BMW waste carrying vehicle wi thin 1 year Maintain all records of incinerator/hydroclaving/autoclaving for a period of 5 years Maintain a log book of each cycle of treatment with all details such as time, date, weight, duration, and hours of treatment CBMWTF No occupier shall establish on their site a BMW treatment and disposal plant, if, a CBMWTF is available within 75 km of the HCF. If no CBMWTF not available, the occupier should establish a BMW treatment and disposal plant after taking prior permission from authority Segregation, packaging, transportation, and storage of BMW BMW classified into 10 categories based on BMW classified into 4 categories based on treatment options treatment options IF untreated human anatomical waste, animal anatomical waste, If untreated BMW should be stored beyond 48 soiled waste, and biotechnology waste should be stored beyond 48 h, h, authorization needed no authorization needed Treatment and disposal of waste Every HCFs shall set up a requisite BMW treatment facility or ensure requisite treatment at a CBMWT Chemical treatment with 1% hypochlorite 973 Chemical treatment with at least 10% hypochlorite having 30% residual chlorine for 20 min or any other equivalent chemical reagent Afr. J. Biomed. Res. Vol. 27, No.6s (December) 2024 Kunal A Majmudar et al. Biomedical Waste Management in India: A Review that should demonstrate microorganisms Deep burial to be allowed in towns with population>5 lakhs Cytotoxic drugs disposal in secured landfills All drugs discarded in black bags All infected metal, plastic, and glass waste to be put in blue bag and then sent for autoclaving, microwaving, and incinerator This was not included Authorization All HCFs treating 1000 or more patients/month need to obtain authorization from SPCB Standards for emission from incinerators Permissible limit for SPM‑150 mg/Nm3 Residence time in secondary chamber of incinerator at least 1s Standards for dioxin and furans – not defined Monitoring of implementation log10 4 reduction efficiency for Deep burial is only an option in remote rural or remote areas, where there is other disposal option. The groundwater table level should be a minimum of 6 m below the lower level of deep burial pit Cytotoxic waste and items contaminated with cytotoxic waste should be returned to manufacturer or CBMWTF for incinerator at 1200° C or encapsulation or plasma pyrolysis at 1200° C All drugs including expired antibiotics should be sent back to manufacturer or to incinerator The BMW waste to be segregated – plastics in red bag, sharps in white container (after mutilation), and glass articles in cardboard box with blue marking; then sent to authorized recycler After proper treatment of plastics and glassware, these recyclables should be given to recyclers having valid registration One time authorization for nonbedded HCFs and for bedded HCFs, the validity of authorization should be coordinated with consent order Permissible limit for SPM‑50 mg/Nm3 Residence time in secondary chamber of incinerator at least 2s Standards for dioxin and furans‑ 0.1 ngTEQ/Nm3 Ministry of environment, forest and climate change should review the implementation of the rules in the country once a year SPCB of each state shall constitute district level monitoring committee under the chairpersonship of district collector or district Not defined magistrate or additional district magistrate to monitor the compliance of the above BMW rules The district level monitoring committee shall submit its report once Not defined every 6 months to the SPCB SPCB = State pollution control board, HCFs = Health care facilities, ETP = Effluent treatment plant, CBMWTF = Common bio‑medical waste treatment and disposal facility, BMW = Biomedical waste, BMWM = Biomedical waste management, SPM = Suspended particulates matter, HCWs = Healthcare workers Not defined Schedule Schedule I Schedule II Schedule III Schedule IV Schedule V Schedule VI 974 Table 3: Difference in schedule for biomedical waste of 1998 and 2016 1998 2016 Categories of waste Color code and type of waste with treatment and disposal Color/code type of waste, Standard for treatment of disposal of BMW (Autoclaving/ waste category, Microwaving/deep burial/dry heat sterilization/chemical disinfection) treatment option Label of BMW List of prescribed authorities and their duties category/bags Part A ‑ label for container/bag Label for transport of Part B ‑ label for transport of BMW BMW bag/container Standard for treatment and Added to schedule II disposal of BMW List of prescribed Added to schedule III authorities and their duties BMW = Biomedical waste Afr. J. Biomed. Res. Vol. 27, No.6s (December) 2024 Kunal A Majmudar et al. Biomedical Waste Management in India: A Review Table 4: Different forms with biomedical waste 2016 Use of the form Accident reporting Application for authorization or renewal of F2 authorization (submitted by occupier of HCWs of CBMWTFs) Authorization (for operating, facility) for generation, F3 collection, reception, treatment, storage, transport, disposal F4 Annual report Application for filling “appeal” against order pass by F5 the prescribed authority HCWs = Healthcare workers, CBMWTFs = Common bio‑medical waste treatment and disposal facilities Forms F1 Biomedical Waste management outside India: A survey on the BMWM status of 24 West Pacific nations, including Japan, China, Australia, New Zealand, the Philippines, Malaysia, Vietnam, Cambodia, the Republic of Korea, Micronesia, Nauru, and Kiribati, was carried out by WHO in 2012. A literature search, a review of publications, newspaper stories, and other information sources were all part of the survey. The five primary areas of BMW—management, training, policy and regulatory framework, implemented technologies, and financial resources—were evaluated for status in each nation. With the exception of Micronesia, Nauru, and Kiribati, all West Pacific nations performed satisfactorily in the areas of management, training, and policies pertaining to BMWM. For BMW logistics and treatment, only Japan and the Republic of Korea use BAT (best available technologies), which were periodically tested and kept in good condition. The majority of the nations lacked or had very little funding for BMWM. As a result, HCWM is still far from ideal in the majority of West Pacific countries. To guarantee that safe HCWM systems are implemented within the next ten years, more support for the expansion of HCWM systems in countries is essential[7]. Across Canada, different provinces have diverse approaches to managing medical waste. Not every province has laws controlling how medical waste is handled and disposed of. However, it seems that Canadian hospitals are shifting from on-site incinerators to centralized provincial facilities for sterilizing BMWs.[8] Biomedical Waste Situation in India: The former Ministry of Environment and Forests notified the Government of India of the first BMW regulations in July 1998.[9] The BMW issue in India was made worse by scavengers who reuse syringes without properly sterilizing them and sort out open, unprotected medical waste without gloves, masks, or shoes for recycling.[3] The International Clinical Epidemiology Network investigated the current BMW procedures, configuration, and framework in basic, secondary, and tertiary healthcare facilities (HCF) in 20 Indian states between 2002 and 2004.[10] They discovered that there was no reliable BMWM system in about 82% of primary, 60% of secondary, and 54% of tertiary HCFs in India. About 240 persons in Gujarat, India, got hepatitis B in 2009 as a result of using unsterilized syringes again.[11] This and numerous other studies demonstrate 975 that even though India was one of the first nations to implement safe BMW disposal policies, immediate action is still required to improve the system's current capacity and boost financing and dedication to safe BMW disposal. The following years saw changes to the BMW 1998 regulations: 2000, 2003, and 2011. Due to disagreements over classification and standards, the 2011 BMW rules draft remained unnotified and remained in draft form. [12] The BMWM regulations have since been modified by the Ministry of Environment, Forests, and Climate Change in March 2016 [Table 1].In order to reduce environmental contamination, these new regulations have improved the procedures of segregation, transportation, and disposal while expanding coverage and streamlining authorization and classification [Table 2]. There are eighteen rules, five forms, and four schedules [Tables 3 and 4].[13] To effectively manage BMW in the nation, the new biological waste management regulations have been announced. These guidelines have been updated to incorporate word handling and improve application clarity. Strict guidelines have also been established to prevent theft of recyclables, secondary handling, and accidental animal spills or dispersing when being transported from the HCFs to the common BMW treatment facility (CBMWTF). Waste collection, segregation, transportation, and disposal are all being improved. By establishing new guidelines for incinerators and enhancing their operations, the concurrent role of incinerators in raising environmental air pollution has been reduced.[13] According to data from the Government of India website, 484 TPD (tonnes per day) of BMW are produced nationwide from 1,68,869 HCFs. Regretfully, 37 TPD remain untreated while only 447 TPD receive treatment. There are currently 198 CBMWTF operating, and another 28 are being built. There are 1,31,837 HCFs that use CBMWTFs, and roughly 21,870 of them have on-site treatment facilities.[13] Any HCF or CBWTF operator wishing to use additional cutting-edge and improved technologies beyond those listed in Schedule I of the Rules must apply to the Central Pollution Control Board (CPCB) in accordance with the BMW Rules, 1998, as amended, in order to have the standards established so that the designated authority can take authorization into consideration. Between 2010 and 2013, the CPCB gave new technologies (not listed Afr. J. Biomed. Res. Vol. 27, No.6s (December) 2024 Kunal A Majmudar et al. Biomedical Waste Management in India: A Review under the BMW Rules) conditional or provisional certification for use in treating BMW. These include PIWS 3000 technology (Static/Mobile), waste sharps dry heat sterilization and encapsulation, plasma pyrolysis, and sharp blasters (needle blasters). Salient Features of Biomedical Waste Rules 2016 1. The regulations now include a wider range of health camps, including those for blood donation, immunization, and surgery [13]. 2. The occupier of an HCF's responsibilities have been updated. The individual with administrative authority over the HCF that is producing BMW is known as the occupier.[8] A. Laboratory, microbiological waste, and blood bags must be pretreated on-site before being disposed of at CBMWTF or on-site. The National AIDS Control Organization (NACO) or WHO guidelines should be followed while sterilizing or disinfecting. B. Within two years after the guidelines' announcement, the use of gloves, blood bags, chlorinated plastic bags, and other items should be gradually discontinued. C. To train all of its healthcare workers and vaccinate them against ailments like tetanus and hepatitis B. D. Before combining with other liquid waste, liquid waste must be pretreated at the source to separate it. E. Putting in place a barcode system for BMW that will allow items to be transferred outside for disposal and treatment. F. All significant incidents, including those brought on by explosions, fire dangers, handling BMWs, and corrective measures carried out by the designated authorities, must be notified. G. Within two years after this notification, the current incinerator must be renovated or modified to meet the new requirement. H. The website's BMW disposal registry must be updated every month and kept up to date every day. 3. A common biomedical waste treatment and disposal facility's (CBMWTF) operator now has more responsibilities.[13] They ought to support the training of the HCW who pick up the rubbish. Additionally, a global positioning system and barcoding should be set up within a year to handle BMW. Keep any documentation related to the incineration, hydroclaving, and autoclaving processes for a duration of five years. 4. BMW's packaging, storage, shipping, and segregation have all improved. Based on color coding, waste kind, and available treatment techniques, biomedical waste has been divided into four groups. Furthermore, untreated biotechnological trash, dirty waste, animal anatomical waste, and human anatomical waste shouldn't be kept in storage for longer than 48 hours. If storage is required for more than 48 hours, the occupier must take all reasonable precautions to guarantee that the trash won't have a negative impact on the environment or human health (no permit is required).[13] 5. If a CBMWTF facility is available 75 kilometers away, no HCF may set up an on-site BMW treatment and disposal plant. In the event that no CBMWTF is accessible, the occupier must first obtain permission 976 from the appropriate authority before setting up the necessary BMW treatment facilities, such as an incinerator, autoclave, microwave, and shredder. These recyclables should be delivered to approved recyclers once the autoclaving or microwave treatment of plastics and glassware has been verified, followed by mutilation or shredding. 6. The occupier is only given permission to dispose of BMWs for nonbedded HCFs once. For bedded HCFs, the authorization's validity and the consent orders' validity must coincide. 7. Incinerator emission standards have been changed to be more ecologically friendly. The acceptable limit for SPM is 50 mg/nm3, the residence period in the incinerator's secondary chamber is two seconds, and the standard for dioxin and furans is 0.1 ng TEQ/Nm 3. 8. Every year, the Ministry of Environment, Forests, and Climate Change will keep an eye on how the regulations are being applied. Each state will be in charge of ensuring compliance by establishing a districtlevel committee headed by the district collector, district magistrate, or additional district magistrate. Additionally, this group will report to the State Pollution Control Board every six months. Benefits of the new biomedical waste rules • India's management of BMWs should change as a result of the new regulations, which are strict and complex. The new regulations now cover a wider range of health-care-related camps, including those for blood donation, vaccinations, and surgery. There are further differences in how BMW waste is separated, packaged, transported, and stored. To make segregation easier, there are now only four groups. One of the fundamental tenets of BMW disposal is that waste must be separated at the point of creation. This has been streamlined to make it convenient and manageable for all HCWs, hence removing the confusion caused by the high number of categories. The bags or containers' color coding (yellow, red, white, and blue) is now associated with a specific waste category and treatment choice. Chemical solid waste and cytotoxic waste, for instance, should be disposed of in yellow bags that are sent for deep burial, plasma pyrolysis, or burning. In order to reduce the risk of infections spreading to healthcare workers handling waste during the treatment stage, the HCF must also pretreat various laboratory waste and blood bags in accordance with WHO and NACO norms. Plastic bags, gloves, and blood bags must be phased out within two years in order to stop dioxin and furan emissions into the environment when they burn. The new regulation also mandates that all bags and containers used for BMW cleaning and disposal have bar codes. Tracking and recognizing bags during inspection for quality assurance and control will be made easier with this step. Only authorized recyclers will receive the BMW in the red/blue bag or container designated for recycling. By doing this, the recycler will remain under the jurisdiction and supervision of several government organizations. Recycling garbage has received more attention in an effort to reduce pollution and conserve Afr. J. Biomed. Res. Vol. 27, No.6s (December) 2024 Kunal A Majmudar et al. Biomedical Waste Management in India: A Review resources. Regarding HCFs' reliance on CBMWTF and who will supply land for CBMWTF establishment, the 2016 rules are more detailed. Land for a CBMWTF will be provided by the state or UT governments, and if a CBMWTF is located within 75 km, no HCF occupant is required to build up an on-site treatment and disposal facility. This offers a number of benefits because it requires a significant financial outlay to establish and operate a separate BMW treatment facility as well as to hire a dedicated, experienced personnel. CBMWTF is a well-liked idea in industrialized nations since it drastically lowers the cost of treatment per kilogram of BMW when used to its maximum capacity. Additionally, this lessens the laboriousness of monitoring and controlling different waste disposal facilities. Additionally, keeping a logbook and records will make documentation easier. The permissible SPM has been dropped to 50 mg/nm3, and the secondary camber retention time has been lowered to 2 seconds, as part of stricter emission regulations for incinerators. This will result in the synthesis of carbon dioxide and water and lessen the emission of dioxins and furans, which are formed at temperatures higher than 600°C. The revised regulations have simplified the permission process and established new standards for HCF authorization. Nonbedded HCFs will receive a one-time authorization, while bedded hospitals will receive automatic authorization. Challenges in the Implementation of New Biomedical Waste 2016 Rules Lack of funding will be one of the main issues small HCFs and government hospitals will have when the BMW 2016 regulations are put into effect. It will be expensive and take too little time—two years—to phase out gloves, blood bags, chlorinated plastic bags, and implement a bar code system for bags and containers. There are now 28 CBMWTFs being built and 198 CBMWTFs operating in India.[13] To meet the demand for the treatment and disposal of all BMW produced in India, a large number of additional CBMWTFs must be developed quickly. Incinerator ash has the potential to be dangerous, and incinerators release harmful air pollutants. Incinerator and its Hazards Burning the garbage was the initial method of BMW disposal. After the first BMW law was put into effect in India in the late 1990s, the number of incinerators installed skyrocketed. It works by killing pathogens at high temperatures while also destroying the substance that the microorganisms live in.[14,15] However, when it operates, a variety of pollutants are created, including dioxins and products of incomplete combustion (PIC). Waste components separate and recombine during incineration and postcombustion cooling to generate new, hazardous particles known as PIC. Metals pose major health problems because they are released into the environment rather than being eliminated. When garbage is burned in an incinerator, dioxins are an unintended byproduct of that combustion. These seventy-five compounds cohabit alongside another class 977 of toxins known as furans. These poisons tend to move up the food chain and build up in adipose tissues. The biggest source of dioxin emissions into the environment is the burning of medical equipment composed of polyvinyl chloride (PVC).[16] Furthermore, metals found in medical waste serve as a catalyst for the production of dioxin. These are extremely harmful, known to cause cancer, and harm the human immune and endocrine systems. To far, the Indian government has not conducted any research to determine the population's dioxin levels. Subramanian et al. discovered a significant concentration of dioxin in human breast milk that was gathered from Kolkata, Mumbai, and New Delhi in 2000.[17] Recognizing the significance of dioxins in the environment, the National Institute for Interdisciplinary Science and Technology and the Council of Scientific and Industrial Research recently began a study in January 2017 to examine the dioxin presence in Thiruvananthapuram.[18] Additionally, incinerator ash is dangerous and must be inspected for toxins before being dumped in a secured landfill. As a result, most nations are switching to more ecologically responsible BMW disposal techniques while taking these factors into account. Both Denmark and the Philippines have outlawed the construction of incinerators.[19, 20] Alternative Technology for Biomedical Waste Disposal The various new technologies for BMW disposal are categorized into four groups – thermal, chemical processes, irradiative processes, and biological processes. Most of these are still under research. [21] Thermal processes are grouped into three – low, medium, and high. I). Microwaves and autoclaves are examples of low heat technologies, which function between 93°C to 177°C. Steam is a sterilizing agent used in autoclaves. Autoclaves are divided into two categories according to how air pickets are removed: prevacuum/high vacuum and gravity/downward displacement. These are preferable because autoclaves with a prevacuum or numerous vacuum cycles provide superior air evacuation. If garbage needs to be reduced in volume or rendered unrecognizable, a shredder or grinder should be employed. Since the evacuated air may include germs, it is cleaned by passing through a high-efficiency particulate absolute (HEPA) filter before being released into the environment. Autoclave sterilization is used for all infectious waste, including cultures, human waste, laboratory waste, soft waste (such as gauze, bandages, and gowns), sharps, and medical equipment. Chemicals and hazardous trash cannot be autoclaved because they emit harmful fumes. Moreover, bulky garbage, bedding, and heat-resistant containers cannot be autoclave disinfected.[21] To disinfect, microwaves use steam and moist heat produced by microwave energy. Sharps, lab waste, human waste, and soft waste (such as gauze, bandages, and gowns) are all sterilized in a microwave. Mercury, radiological waste, and volatile and semivolatile organic substances should not be placed in a microwave. Minimal emissions are a benefit of Afr. J. Biomed. Res. Vol. 27, No.6s (December) 2024 Kunal A Majmudar et al. Biomedical Waste Management in India: A Review disposing of BMWs in a microwave. Its drawbacks include a high setup cost, an odor issue close to the unit, and the potential for microwave radiation leakage. II). The temperature range for medium heat technologies, which include thermal depolymerization and reverse polymerization, is 177°C to 540°C. In order to break down the organic matter, high-energy microwaves are applied in a nitrogen atmosphere to BMW. The trash undergoes molecular-level chemical breakdown and internal energy increase when it absorbs microwave energy. Nitrogen creates an atmosphere devoid of oxygen, preventing burning. The garbage is then mutilated using shredders [21]. III). High heat technologies, such as pyrolysis-oxidation, plasma pyrolysis, induction-based pyrolysis, and lasebased pyrolysis, function at temperatures ranging from 540°C to 8300°C. Glass and metal pieces, as well as inert ash, are left behind after the organic solid and liquid waste in the pyrolysis chamber vaporizes at a high temperature (around 594°C) during pyrolysis oxidation. The second stage comes next, in which the vapors are burned in a chamber between 982°C and 1093°C, and clean exhaust steam is then emitted. Plasma torches are used in plasma pyrolysis to produce plasma energy. The ionized gas can carry electricity while it is in the plasma state, but the electric energy is transformed into thermal energy because of its high resistance. Among the residues produced are metallic residues, vitrified glass aggregates, and carbon black. Plasma-based technology can eliminate a wide range of waste, including infectious waste, sharps, plastics, dialysis waste, hazardous trash, chemotherapy waste, and low-level radioactive waste (with the exception of mercury, which plasma systems cannot manage). This technology has several benefits, including a low emission rate, environmentally friendly waste residue that is inert and sterile, and a 95% and 80%–90% reduction in volume and mass. Its drawbacks include expensive startup and operating costs, high electricity consumption, a short plasma torch lifespan, and the potential to produce dioxins in a badly built setup.[22] Chemical‑based technology Numerous chemicals used to dispose of BMWs are presently being developed. Chemical-based technology treats a variety of waste types, such as cultures, sharps, liquid waste, human waste, laboratory trash, and soft waste (such as gowns, bandages, and gauze). Chemicalbased procedures should not be used to treat radioactive waste, mercury, volatile, or semi-volatile organic chemicals. To prevent aerosol formation during shredding, the chemical-based technology needs a closed system or is run under negative pressure, and the exhausted air must be passed through HEPA. In chemical-based technologies, BMW shredding is essential. Chemical-based technology has the advantages of being fully automated, simple to operate, easy to discharge liquid effluent into sewer, and producing no combustion byproducts. The drawbacks include chemical risks, the frequent generation of disagreeable odors, and poisonous byproducts from the extensive use of chlorine and hypochlorite. Chlorine978 based and nonchlorine-based systems are the two categories of chemical-based technology. Chlorine dioxide or sodium hypochlorite are used in the chlorine-based system. One of the earliest chemical disinfectants used to cure BMW was sodium hypochlorite. It has recently been demonstrated that the use of sodium hypochlorite results in the emission of toxins such dioxins, halo acetic acid, and chlorinated aromatic compounds. Since chlorine dioxide is unstable, it is produced and utilized locally. It's a powerful biocide. It does not react with alcohol or ammonium, breaks down to form salt, and produces less pollutants when used. Nonchlorine-based technologies can cure BMW using a gas, liquid, or dry chemical. A small number of these systems are included here, but many have entered the market. The SteriiEcocycle 104 collects trash in a portable chamber and adds a decontaminant vial containing peracetic acid. Peracetic acid disinfects the waste after 10 to 12 minutes, and a HEPA filter stops aerosolized microorganisms from escaping. The garbage is dumped into the sewer as ordinary rash along with the liquid effluent.[21] Alkaline hydrolysis at high temperatures is used in waste reduction (WR)[2] technology to transform microbial and human waste into a neutral aqueous solution. It is utilized for biodegradable bags, bodily fluids, and human or tissue waste. It is also capable of handling chemotherapeutic waste. Additionally, fixative sin tissues and other dangerous substances like formaldehyde and glutaraldehyde are destroyed by the alkali. For biodegradable trash like bone and teeth, this automated system has a steam-jacketed stainless steel container with a retainer.[21] Lynntech’s another technology uses ozone fordecontamination of BMW. Being a strong oxidant, ozonedestroys microbes and converts into molecular oxygen.[21]. Ionizing radiation damages DNA, and it also damages infectious particle proteins and enzymes by generating free radicals. The electron beam technique creates ionizing radiation by striking the object with a high-energy electron beam that is propelled quickly. Sharps, soft waste (such as gauze, bandages, and gowns), laboratory trash, and infectious waste—such as human excrement—need to be managed. Mercury, radioactive waste, and volatile and semi-volatile organic chemicals shouldn't be handled in electron beam systems. This approach has several benefits, including minimal operating costs, complete automation, no ionizing radiation once the machine is turned off, no liquid effluent, and no harmful emissions. The drawbacks include radiation protection, a concrete shield that is several feet thick around the system, ozone gas removal, no reduction in waste volume, and the requirement for shredders or grinders.[21] BMW can be disposed of biologically using a new technology termed a "Bio-converter" (9 Biomedical Disposal, Inc.). Medical waste is decontaminated using an enzyme solution, and the resulting sludge is then delivered to a landfill after passing through an extruder that removes water for sewage disposal. Biodegradable plastics are another way to dispose of BMWs in an environmentally friendly manner. Microbial extracellular enzymes cause biological deterioration of Afr. J. Biomed. Res. Vol. 27, No.6s (December) 2024 Kunal A Majmudar et al. Biomedical Waste Management in India: A Review several biomedical implants made of biodegradable polymers. When famine and an appropriate substrate are unavailable, these microorganisms use these biodegradable polymers as a substrate. For the economical large-scale production of biodegradable polymers, more study is required.[21, 23] Conclusions: BMWM should be a collaborative effort with strong legislative support, devoted government support, good BMW practices adhered to by HCFs and healthcare professionals, and ongoing oversight of BMW procedures. Living in a safe and clean environment is one of our fundamental rights. Waste separation at the source and WR is the cornerstone of BMWM. In order to reduce environmental pollution and guarantee the security of the employees, patients, and general public, the current BMWM 2016 regulations are an upgrade over previous ones in terms of better segregation, transportation, and disposal techniques. Additionally, it is important to promote the use of non-PVC medical devices and the creation of more modern, environmentally friendly methods for disposing of BMW. A cleaner and greener environment should be guaranteed by all BMWM participants. References 1. Chartier Y, Emmanuel J, Pieper U, Prüss A, Rushbrook P, Stringer R, editors. Safe Management of Wastes from Health‑Care Activities. 2nd ed. Geneva, Switzerland: WHO Press; 2014. p. 1‑146. 2. Li CS, Jenq FT. Physical and chemical composition of hospital waste. Infect Control Hosp Epidemiol 1993;14:145‑50. 3. WHO. Review of Health Impacts from Microbiological Hazards in Health‑Care Wastes. Geneva: World Health Organization; 2004. 4. Secretariat of the Basel Convention. Technical Guidelines on Environmentally Sound Management of Wastes Consisting of Elemental Mercury and Wastes Containing or Contaminated with Mercury 31 October, 2011. Geneva: Basel Convention and United Nations Environment Programme; 2011. 5. Secretariat of the Stockholm Convention. Revised Draft Guideline on Best Available Techniques and Provisional Guidance on Best Environmental Practices of the Stockholm Convention on Persistent Organic Pollutants. Geneva: Secretariat of the Stockholm Convention; 2006. 6. David Lennett, Richard Gutierrez. Countries: List of signatories. In: Minamata Convention on Mercury. Geneva: United Nations Environment Programme; 2014. 7. Available from: https://www.google.co.in/search?rlz=1C1RLNS_e nIN730IN730&q=WHO+Bio+medical+waste +wes+pacific&oq= WHO+Bio+medical+waste+west+pacific and gs_l=psy‑ab. 3.4449.8 925.0.9286.20.15.0.0.0 979 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. .0.393.2252.2‑6j2.8.0.0.1.1.64.psy‑ab. 16.1.245.0i1 3k1j0i13i30k1.0.ymdTNBt‑k68#. Walkinshaw E. Medical waste‑management practices vary across Canada. CMAJ 2011;183:E1307‑8. Ministry of Environment and Forests Notification. Bio‑Medical Waste (Management and Handling, 1998) Rules. New Delhi: Government of India Publications; 1998. p. 276‑84. INCLEN Program Evaluation Network (IPEN) Study Group, New Delhi, India. Bio‑medical waste management: Situational analysis & predictors of performances in 25 districts across 20 Indian states. Indian J Med Res 2014;139:141‑53. Seetharam S. Hepatitis B outbreak in Gujarat: A wake‑up call. Indian J Med Ethics 2009;6:120‑1. The Gazette of India Biomedical Wastes (Management and Handling) Rules, India: Ministry of Environment and Forests, Government of India. Notification Dated; 20th July, 1998. Bio‑Medical Waste Management Rules, 2016. Published in the Gazette of India, Extraordinary, Part II, Section 3, Sub‑Section (i), Government of India Ministry of Environment, Forest and Climate Change. Notification; New Delhi, the 28th March, 2016. Mattiello A, Chiodini P, Bianco E, Forgione N, Flammia I, Gallo C, et al. Health effects associated with the disposal of solid waste in landfills and incinerators in populations living in surrounding areas: A systematic review. Int J Public Health 2013;58:725‑35. Available from: http://www.bsem.org.uk/uploads/ IncineratorReport_v3.pdf. Vilavert L, Nadal M, Schuhmacher M, Domingo JL. Two decades of environmental surveillance in the vicinity of a waste incinerator: Human health risks associated with metals and PCDD/Fs. Arch Environ Contam Toxicol 2015;69:241‑53. Subramanian A, Ohtake M, Kunisue T, Tanabe S. High levels of organochlorines in mothers’ milk from Chennai (Madras) city, India. Chemosphere 2007;68:928‑39. Available from: http://www.timesofindia.indiatimes.com/city/ thiruvananthapuram/pcb‑to‑study‑dioxin‑presence ‑in‑city/ articleshow/56506072.cms. [Last accessed on 2017 Oct 31]. Av a i l a b l e f r o m : h t t p s : / / w w w . g o o g l e . c o . i n / s e a r c h ? r l z =1C1RLNS_ e n IN73 0 IN730&q=p h i l ip p i n e s+banned+ i n c i n e r a t o r a n d spell=1&sa=X& ved=0ahUKEwjbnN‑Fu47WAhXDLI8KHdTaAi4 QvwUIIigA &biw=1536&bih=804#. Available from: https://www.google.co.in/search?rlz=1C1RLNS_e nIN730IN730&biw=1536&bih=804&q=Den mark+no+incinerator&oq=Denmark+no+incinerat or&gs_l=psy‑ab.3.29779.3 7388.0.38582.32.18.2.0.0.0.456.3675.2‑9j3j1.13.0 .0.1.1.64.psy‑ab.18.11.2597.0j0i67k1j0i7i30k1j0i Afr. J. Biomed. Res. Vol. 27, No.6s (December) 2024 Kunal A Majmudar et al. Biomedical Waste Management in India: A Review 7i5i30k1j0i8i 13i30k1j0i5i30k1j0i8i 30k1j0i8i7i30k1.eVw9zPpBfaA#. 21. Emmanuel J. Non‑Incineration Medical Waste Treatment Technologies. Washington, DC: Health Care without Harm; 2001. 22. Nema SK, Ganeshprasad KS. Plasma pyrolysis for medical waste. Curr Sci 2002;83:271‑8. 23. Roohi, Bano K, Kuddus M, Zaheer MR, Zia Q, Khan MF, et al. Microbial enzymatic degradation of biodegradable plastics. Curr Pharm Biotechnol 2017;18:429‑40. 980 Afr. J. Biomed. Res. Vol. 27, No.6s (December) 2024 Kunal A Majmudar et al.
0
You can add this document to your study collection(s)
Sign in Available only to authorized usersYou can add this document to your saved list
Sign in Available only to authorized users(For complaints, use another form )