Ericsson Internal INSTRUCTION Prepared (Subject resp) 1 (45) No. Adwin Wendi Zulfikar Approved (Document resp) Checked Date Rev 2019-02-01 Reference MOBILY MODERNIZATION Mobily 5G New Integration 1 Revision History Rev No. Created By Remarks Date PA Adwin Wendi Zulfikar Draft Version 24-11-2019 PA1 Adwin Wendi Zulfikar Revision 08-12-2019 PA2 Adwin Wendi Zulfikar Revision 23-01-2020 PA3 Adwin Wendi Zulfikar Revision + additional scenario 2 01-06-20 PA4 Adwin Wendi Zulfikar Revision + additional scenario 3 16-08-20 Ericsson Internal INSTRUCTION Prepared (Subject resp) 2 (45) No. Adwin Wendi Zulfikar Approved (Document resp) Checked Date 2019-02-01 Rev Reference MOBILY MODERNIZATION +++++++++++++++++++++++ SCENARIO 01 +++++++++++++++++++++++ PREPARATION DESIGN 1. Solution Diagram Please follow SAF for each site and IPRAN and CDD from design Team. 1. Preparation PCI script for ZT-LMT Script. Ericsson Internal INSTRUCTION Prepared (Subject resp) 3 (45) No. Adwin Wendi Zulfikar Approved (Document resp) Checked Date Rev 2019-02-01 Reference MOBILY MODERNIZATION - Need to confirm about IP Design to IPRAN team lead is Asad Azeem Rezvi asad.azeem.rezvi@ericsson.com - Need to confirm about CDD to Design Team so please communicates with Sami Al-Ruhaili sami.alruhaili@ericsson.com - Based on IP RAN and CDD please sent email to PCI Team Wei Chang wei.chang@ericsson.com and Mary Ma Y mary.y.ma@ericsson.com who is team lead for preparation script. 2. License request with below template for anchoring LTE and NR please fullfill as per channel bandwidth for TDD and FDD requested. LTE_NSA_ANCHORI NG INTEGRATION PROCESS 1. LTE Anchoring Configuration - Please make dump dcgm and also CV before activity. Please run below script and take the result and save on our sharefolder run /home/shared/ecfggkf/ejuguan/scripts/precheck_3G.mos run /home/shared/ecfggkf/ejuguan/scripts/precheck_4G.mos run /home/shared/ecfggkf/ejuguan/scripts/postcheck_3G.mos run /home/shared/ecfggkf/ejuguan/scripts/postcheck_4G.mos sharefolder https://ericsson.sharepoint.com/sites/5GRANMOBILYPREPARATION/Shared%20Documents/Forms/ AllItems.aspx?viewid=9bdbec43%2D4c9e%2D4db8%2Dbd72%2D73d7861a9ebd&id=%2Fsites %2F5GRANMOBILYPREPARATION%2FShared%20Documents%2F5G%20RISE%20PHASE %2002%2FDUMP%20PRE%20MDT - Upgrade enode B to MTR20.Q1 or latest SW from ENM >>> this step should be done on LTE 5G anchoring Ericsson Internal INSTRUCTION Prepared (Subject resp) 4 (45) No. Adwin Wendi Zulfikar Approved (Document resp) Checked Date Rev 2019-02-01 Reference MOBILY MODERNIZATION LTE B43 CXP9024418/6_R85H24 LTE B41 CXP9024418/6_R85E40 LTE B41 CXP9024418/6_R85E40 - Install the license from ENM and please check important license about “ Basic Intelligent Connectivity” should be license state. >>>> >>> this step should be done on LTE 5G anchoring - Create X2 for 5G anchoring as below script Please make sure to change site ID and IP for X2 5G $siteID = 2241 gs+ crn ENodeBFunction=1,GUtraNetwork=1 userLabel end gslset ENodeBFunction=1 intraRanIpAddressRef Router=vr_S1CP,InterfaceIPv4=S1CP,AddressIPv4=1 y gs+ crn ENodeBFunction=1,EndcProfile=1 meNbS1TermReqArpLev 0 userLabel 5G_NSA end gslset ENodeBFunction=1,QciTable=default,QciProfilePredefined=qci9 endcProfileRef y gs+ crn ENodeBFunction=1,GUtraNetwork=1,ExternalGNodeBFunction=4203-52$siteID ENodeBFunction=1,EndcProfile=1 Ericsson Internal INSTRUCTION Prepared (Subject resp) 5 (45) No. Adwin Wendi Zulfikar Approved (Document resp) Checked Date 2019-02-01 Rev Reference MOBILY MODERNIZATION gNodeBId 52$siteID gNodeBIdLength 23 gNodeBPlmnId mcc=420,mnc=3,mncLength=2 userLabel end gsgs+ crn ENodeBFunction=1,GUtraNetwork=1,ExternalGNodeBFunction=4203-52$siteID,TermPointToGNB=4203-52$siteID administrativeState 0 domainName ipAddress 10.196.111.218 ipv6Address :: end gs- - Please run 5G baseline as below - lt all - cvms b4_5G_BL - confb+ - gs+ - set SecurityHandling=1 integrityProtectAlgoPrio 1 - set SecurityHandling=1 cipheringAlgoPrio 1 2 0 - lset CXC4012218 featureState 1 - set EndcProfile=1 meNbS1TermReqArpLev 0 - set EndcProfile=1 splitNotAllowedUeArpLev 0 - lset ENodeBFunction=1 - set LoadBalancingFunction=1 intraRanIpAddressRef Router=vr_S1CP,InterfaceIPv4=S1CP,AddressIPv4=1 lbAllowedForEndcUe false Ericsson Internal INSTRUCTION Prepared (Subject resp) 6 (45) No. Adwin Wendi Zulfikar Approved (Document resp) Checked Date Rev 2019-02-01 Reference MOBILY MODERNIZATION - lset EUtranCell.DD=....-...$ extGUtranCellRef - lset EUtranCell.DD=....-...$ endcAllowedPlmnList mcc=420,mnc=03,mncLength=2 - lset EUtranCell.DD= primaryUpperLayerInd 1 - lset EUtranCell.DD= upperLayerIndR15Usage true - lset EUtranCell.DD=.*,UeMeasControl=1,ReportConfigB1GUtra=1 b1Threshold 46 - lset EUtranCell.DD=.*,UeMeasControl=1,ReportConfigB1GUtra=1 hysteresisB1 3 - lset EUtranCell.DD=.*,UeMeasControl=1,ReportConfigB1GUtra=1 timeToTriggerB1 640 - lhget EUtranCellFDD=.*,UeMeasControl=1,ReportConfigB1GUtra=1 b1Threshold|hysteresisB1|timeToTriggerB1 - set ,ENodeBFunction=1,QciTable=default,QciProfilePredefined=qci[678]$ endcProfileRef EndcProfile=1 - seti QciTable=default,QciProfilePredefined=qci[6789]$ dualConnInitUlConf 1 - set ENodeBFunction endcSplitAllowedNonDynPwrShUe true - scd all - scw 4052:4,4072:1 - invlr basic - lset ENodeBFunction=1$ endcDataUsageReportEnabled TRUE - lset EUtranCellTDD=....-11[ABC]$ endcAllowedPlmnList - crn ENodeBFunction=1,PmFlexCounterFilter=NR_ACTIVE - endcFilterEnabled true - endcFilterMin 2 - end - crn ENodeBFunction=1,PmFlexCounterFilter=NR_MATCHED - endcFilterEnabled true - endcFilterMin 1 - end - crn ENodeBFunction=1,PmFlexCounterFilter=NR_CAPABLE Ericsson Internal INSTRUCTION Prepared (Subject resp) 7 (45) No. Adwin Wendi Zulfikar Approved (Document resp) Checked Date Rev 2019-02-01 - endcFilterEnabled true - endcFilterMin 0 - end Reference MOBILY MODERNIZATION - confb- - gs- - cvms after_5G_BL - deb gnb - y - wait 2 - st gnb Please unlocked for termpointToGNB and ExternalGUtranCell should be create automatically if X2 enable and correctly setup. ** if not enable so you need to make sure IP for control plane on GNB should be the same and try to delete create from enode B, during this creation please make sure cell is enable on GNB. 2. NR Integration - Please request and check script for ZT from PCI Team on respective email - Please double check about OAM IP and gateway router IP and VLAN for OAM before we load on ENM - Please load ZT script to ENM as below step Ericsson Internal INSTRUCTION Prepared (Subject resp) 8 (45) No. Adwin Wendi Zulfikar Approved (Document resp) Checked Date 2019-02-01 Rev Reference MOBILY MODERNIZATION Ericsson Internal INSTRUCTION Prepared (Subject resp) 9 (45) No. Adwin Wendi Zulfikar Approved (Document resp) Checked Date 2019-02-01 Rev Reference MOBILY MODERNIZATION Please make sure OAM IP & default gateway for OAM & VLAN ID on below script - SiteInstallation_Mobily_Mobily_Saudi_ - 01_SiteBasic_Mobily_Mobily_Saudi_ Ericsson Internal INSTRUCTION Prepared (Subject resp) 10 (45) No. Adwin Wendi Zulfikar Approved (Document resp) Checked Date 2019-02-01 Rev Reference MOBILY MODERNIZATION Ericsson Internal INSTRUCTION Prepared (Subject resp) 11 (45) No. Adwin Wendi Zulfikar Approved (Document resp) Checked Date 2019-02-01 Rev Reference MOBILY MODERNIZATION Ericsson Internal INSTRUCTION Prepared (Subject resp) 12 (45) No. Adwin Wendi Zulfikar Approved (Document resp) Checked Date 2019-02-01 Rev Reference MOBILY MODERNIZATION - Please provide SIF file script that you has been download from ENM to our field team - Ask him to load from site use LMT - Please monitor the progress on ENM until integration complete status as below Ericsson Internal INSTRUCTION Prepared (Subject resp) 13 (45) No. Adwin Wendi Zulfikar Approved (Document resp) Checked Date Rev 2019-02-01 Reference MOBILY MODERNIZATION - Please confirm with ASP that LMT from end site has been 100% also - Please check by moshell the site and make sure cell has been define and sector define - Please check site should be synch with ENM as below Ericsson Internal INSTRUCTION Prepared (Subject resp) 14 (45) No. Adwin Wendi Zulfikar Approved (Document resp) Checked Date 2019-02-01 Rev Reference MOBILY MODERNIZATION Ericsson Internal INSTRUCTION Prepared (Subject resp) 15 (45) No. Adwin Wendi Zulfikar Approved (Document resp) Checked Date Rev 2019-02-01 - Please enter the GNB and please do below post check command Please make sure cell is locked - Please try to ping gateway for S1-U and X2 interface and make sure all interface is OK from GnodeB - Please try to ping SGW and MME from Gnode B Reference MOBILY MODERNIZATION Ericsson Internal INSTRUCTION Prepared (Subject resp) 16 (45) No. Adwin Wendi Zulfikar Approved (Document resp) Checked Date 2019-02-01 Rev Reference MOBILY MODERNIZATION - Please double check for ARFCN and FREQ and SSB and channel band with suppose as per design. - Please check synchronization – GPS suppose ENABLE – Radio clock suppose ENABLE – and make sure RadioClockState is RNT_TIME_LOCKED - Please unlocked cell and sector from GNB - Please make sure all enable Ericsson Internal INSTRUCTION Prepared (Subject resp) 17 (45) No. Adwin Wendi Zulfikar Approved (Document resp) Checked Date 2019-02-01 Rev Reference MOBILY MODERNIZATION - Please check termination X2 suppose created by system and ENABLE If disable you need to check terminationGnB on LTE anchoring… suppose unlocked and enable. - Please load below for synchE and synch PTP definition on GnodeB gs+ set FeatureState=CXC4040007 FeatureState 1 set FeatureState=CXC4040008 FeatureState 1 set FeatureState=CXC4011710 FeatureState 1 set FeatureState=CXC4040011 featureState 1 cr Transport=1,Ptp=1 crn Transport=1,Ptp=1,BoundaryOrdinaryClock=PTP_ROUTER clockType 2 domainNumber 24 priority1 255 priority2 255 Ericsson Internal INSTRUCTION Prepared (Subject resp) 18 (45) No. Adwin Wendi Zulfikar Approved (Document resp) Checked Date Rev 2019-02-01 Reference MOBILY MODERNIZATION ptpProfile 2 end crn Transport=1,Synchronization=1,RadioEquipmentClock=1,RadioEquipmentClockReference=PTP_ROUTER adminQualityLevel qualityLevelValueOptionI=1,qualityLevelValueOptionII=2,qualityLevelValueOptionIII=1 administrativeState 1 encapsulation Ptp=1,BoundaryOrdinaryClock=PTP_ROUTER holdOffTime 1000 priority 2 useQLFrom 1 waitToRestoreTime 60 end crn Transport=1,Ptp=1,BoundaryOrdinaryClock=PTP_ROUTER,PtpBcOcPort=1 administrativeState 1 announceMessageInterval -3 associatedGrandmaster asymmetryCompensation 0 dscp 54 durationField 300 localPriority 128 masterOnly false pBit 1 ptpMulticastAddress 0 ptpPathTimeError 1000 syncMessageInterval -4 transportInterface EthernetPort=TN_C transportVlan end Ericsson Internal INSTRUCTION Prepared (Subject resp) 19 (45) No. Adwin Wendi Zulfikar Approved (Document resp) Checked Date Rev 2019-02-01 Reference MOBILY MODERNIZATION crn Transport=1,Synchronization=1,SyncEthInput=1 encapsulation EthernetPort=TN_C end crn Transport=1,Synchronization=1,RadioEquipmentClock=1,RadioEquipmentClockReference=SyncE adminQualityLevel qualityLevelValueOptionI=2,qualityLevelValueOptionII=2,qualityLevelValueOptionIII=1 administrativeState 1 encapsulation Synchronization=1,SyncEthInput=1 holdOffTime 1000 priority 2 useQLFrom 1 waitToRestoreTime 60 end gs- - Please delete create for PTP synch on 5G baseband as below command confb+ gs+ bl RadioEquipmentClockReference=PTP_ROUTER del RadioEquipmentClockReference=PTP_ROUTER ldel Ptp=1 run /home/shared/80075848/PTP_ROUTER.mos st radio wait 4 st radio confbgs- - Please run 5G baseline as below run /home/shared/common/ab_automation/tools/nr_health_check choose 1 if you need to run on LTE choose 2 if you need to run on NR Ericsson Internal INSTRUCTION Prepared (Subject resp) 20 (45) No. Adwin Wendi Zulfikar Approved (Document resp) Checked Date Rev 2019-02-01 - Reference MOBILY MODERNIZATION CHECKLIST 5G Integration Site ID Cell Status Riport&Rilin k X2 Status BW Status SC Statu s Power Status 5G BL SW NOJD440 9 ARFC N Status OK OK OK OK OK OK OK DONE MTR19Q3C 5G BL should running after finishing on 5G baseband run /home/shared/common/ab_automation/tools/nr_health_check and choose : 2 Before you running correction as below so you need to lock manually sector and cell Ericsson Internal INSTRUCTION Prepared (Subject resp) 21 (45) No. Adwin Wendi Zulfikar Approved (Document resp) Checked Date Rev 2019-02-01 Reference MOBILY MODERNIZATION Please verify that all correction is loading properly. Need to run also our 5G baseline on NR - run /home/shared/80075848/5G_BL_B43_AIR6448_PH02 SW should be on MTR20.Q1 - keep it on below Baseband_RadioNode CXP9024418/6_R85E40 If not please upgrade it to that SW Activate Scanner as below for 5G NR pcrp NR_SCANNER /home/shared/common/ab_automation/data/other/scanner.txt NEED TO CHECK PING to MME and SGW from NR with below mcc Router=Traffic_X2 ping 10.22.230.97 y mcc Router=Traffic_S1 ping 10.20.119.113 y Need to define externalnode to Master node as below script Masternode LTE or 3G or 2G baseband Run /home/shared/80075848/EC_LTE.txt Run /home/shared/80075848/EC_BUS_NR.txt ********************************************************** NEW MO need to be created on MTR20.Q1 B43 with AIR 6488 ********************************************************** - LTE side : please run this script and make sure you run as much as how many termination Gnb has been created - NR side : please run new MO mobility on NR with below script Ericsson Internal INSTRUCTION Prepared (Subject resp) 22 (45) No. Adwin Wendi Zulfikar Approved (Document resp) Checked Date 2019-02-01 Rev Reference MOBILY MODERNIZATION Need to checklist for NR B78 as below - power suppose 160 watts configuredMaxTxPower 160000 - activate CSI 32 port as below command : setm NRCellDU= csiRsConfig16P csiRsControl16Ports=0,i11Restriction=,i12Restriction= csiRsConfig32P csiRsControl32Ports=EIGHT_TWO_N1AZ,i11Restriction=FFFFFFFF,i12Restriction=FF csiRsConfig8P csiRsControl8Ports=1,i11Restriction=FFFF,i12Restriction= - TDD pattern suppose as below - Make sure bfnoffset = 0 - SC for B43 AIR6488 scw RC18:1 scw RC34:1 scw RC35:1 scw RP139:20 scw RP78:61 Ericsson Internal INSTRUCTION Prepared (Subject resp) 23 (45) No. Adwin Wendi Zulfikar Approved (Document resp) Checked Date Rev 2019-02-01 Reference MOBILY MODERNIZATION +++++++++++++++++++++++ SCENARIO 02 Mixed Radio 4418 between TDD + NR +++++++++++++++++++++++ All preparation is same as B43 scenario 01 ( 5G preparation activity + antenna swap ( if there is ) + 5G integration ) - please refer on SAF/TSSR to make sure which scenario supposed to implement Radio existing for LTE TDD ( RRUS72B41 ) will be replace to B41 radio 4418 so LTE TDD and NR will be mixedmode Radio We need to reconfigure branch on LTE TDD SW on LTE and NR for b41 5G baseline on NR is different Script new MO on LTE and NR is different. STEP : 1. After 5G preparation done and antenna swap for low band done ( if there is ) 2. We need to reconfigure branch and power on LTE side. Layer Config & Ericsson Internal INSTRUCTION Prepared (Subject resp) 24 (45) No. Adwin Wendi Zulfikar Approved (Document resp) Checked Date 2019-02-01 Rev Reference MOBILY MODERNIZATION Power TDD 1st carrier 2T4R, 2x20W TDD 2nd carrier 2T4R, 2x20W TDD 3rd carrier 4T4R, 4x10W NR – 40 MHz 4T4R, 4x10W Need to enter LTE with deprecate mode amos -v exclude_deprecated=1 LOJDXXXX bl EUtranCellTDD bl SectorEquipmentFunction=S.-TDD lset FieldReplaceableUnit=RRU-1[345] isSharedWithExternalMe true set SectorEquipmentFunction=S.-TDD mixedModeRadio true set SectorCarrier=.*-1 partOfSectorPower 100 set SectorCarrier=.*-1 noOfRxAntennas 4 set SectorCarrier=.*-1[12] noOfTxAntennas 2 set SectorCarrier=.*-13 noOfTxAntennas 4 set SectorCarrier=.*-1 configuredMaxTxPower 40000 confb+ gs+ lset SectorCarrier=.*-11A rfBranchTxRef Equipment=1,AntennaUnitGroup=S1-TDD,RfBranch=1 Equipment=1,AntennaUnitGroup=S1TDD,RfBranch=3 lset SectorCarrier=.*-11B rfBranchTxRef Equipment=1,AntennaUnitGroup=S2-TDD,RfBranch=1 Equipment=1,AntennaUnitGroup=S2TDD,RfBranch=3 lset SectorCarrier=.*-11C rfBranchTxRef Equipment=1,AntennaUnitGroup=S3-TDD,RfBranch=1 Equipment=1,AntennaUnitGroup=S3TDD,RfBranch=3 lset SectorCarrier=.*-12A rfBranchTxRef Equipment=1,AntennaUnitGroup=S1-TDD,RfBranch=2 Equipment=1,AntennaUnitGroup=S1TDD,RfBranch=4 lset SectorCarrier=.*-12B rfBranchTxRef Equipment=1,AntennaUnitGroup=S2-TDD,RfBranch=2 Equipment=1,AntennaUnitGroup=S2TDD,RfBranch=4 lset SectorCarrier=.*-12C rfBranchTxRef Equipment=1,AntennaUnitGroup=S3-TDD,RfBranch=2 Equipment=1,AntennaUnitGroup=S3TDD,RfBranch=4 lset SectorCarrier=.*-13A rfBranchTxRef Equipment=1,AntennaUnitGroup=S1-TDD,RfBranch=1 Equipment=1,AntennaUnitGroup=S1TDD,RfBranch=2 Equipment=1,AntennaUnitGroup=S1-TDD,RfBranch=3 Equipment=1,AntennaUnitGroup=S1-TDD,RfBranch=4 lset SectorCarrier=.*-13B rfBranchTxRef Equipment=1,AntennaUnitGroup=S2-TDD,RfBranch=1 Equipment=1,AntennaUnitGroup=S2TDD,RfBranch=2 Equipment=1,AntennaUnitGroup=S2-TDD,RfBranch=3 Equipment=1,AntennaUnitGroup=S2-TDD,RfBranch=4 lset SectorCarrier=.*-13C rfBranchTxRef Equipment=1,AntennaUnitGroup=S3-TDD,RfBranch=1 Equipment=1,AntennaUnitGroup=S3TDD,RfBranch=2 Equipment=1,AntennaUnitGroup=S3-TDD,RfBranch=3 Equipment=1,AntennaUnitGroup=S3-TDD,RfBranch=4 confbgsconfb+ gs+ lset SectorCarrier=.*-11A rfBranchRxRef Equipment=1,AntennaUnitGroup=S1-TDD,RfBranch=1 Equipment=1,AntennaUnitGroup=S1-TDD,RfBranch=2 Equipment=1,AntennaUnitGroup=S1-TDD,RfBranch=3 Equipment=1,AntennaUnitGroup=S1-TDD,RfBranch=4 lset SectorCarrier=.*-11B rfBranchRxRef Equipment=1,AntennaUnitGroup=S2-TDD,RfBranch=1 Equipment=1,AntennaUnitGroup=S2-TDD,RfBranch=2 Equipment=1,AntennaUnitGroup=S2-TDD,RfBranch=3 Equipment=1,AntennaUnitGroup=S2-TDD,RfBranch=4 lset SectorCarrier=.*-11C rfBranchRxRef Equipment=1,AntennaUnitGroup=S3-TDD,RfBranch=1 Equipment=1,AntennaUnitGroup=S3-TDD,RfBranch=2 Equipment=1,AntennaUnitGroup=S3-TDD,RfBranch=3 Equipment=1,AntennaUnitGroup=S3-TDD,RfBranch=4 lset SectorCarrier=.*-12A rfBranchRxRef Equipment=1,AntennaUnitGroup=S1-TDD,RfBranch=1 Equipment=1,AntennaUnitGroup=S1-TDD,RfBranch=2 Equipment=1,AntennaUnitGroup=S1-TDD,RfBranch=3 Equipment=1,AntennaUnitGroup=S1-TDD,RfBranch=4 lset SectorCarrier=.*-12B rfBranchRxRef Equipment=1,AntennaUnitGroup=S2-TDD,RfBranch=1 Equipment=1,AntennaUnitGroup=S2-TDD,RfBranch=2 Equipment=1,AntennaUnitGroup=S2-TDD,RfBranch=3 Equipment=1,AntennaUnitGroup=S2-TDD,RfBranch=4 lset SectorCarrier=.*-12C rfBranchRxRef Equipment=1,AntennaUnitGroup=S3-TDD,RfBranch=1 Equipment=1,AntennaUnitGroup=S3-TDD,RfBranch=2 Equipment=1,AntennaUnitGroup=S3-TDD,RfBranch=3 Equipment=1,AntennaUnitGroup=S3-TDD,RfBranch=4 lset SectorCarrier=.*-13A rfBranchRxRef Equipment=1,AntennaUnitGroup=S1-TDD,RfBranch=1 Equipment=1,AntennaUnitGroup=S1-TDD,RfBranch=2 Equipment=1,AntennaUnitGroup=S1-TDD,RfBranch=3 Equipment=1,AntennaUnitGroup=S1-TDD,RfBranch=4 lset SectorCarrier=.*-13B rfBranchRxRef Equipment=1,AntennaUnitGroup=S2-TDD,RfBranch=1 Equipment=1,AntennaUnitGroup=S2-TDD,RfBranch=2 Equipment=1,AntennaUnitGroup=S2-TDD,RfBranch=3 Equipment=1,AntennaUnitGroup=S2-TDD,RfBranch=4 lset SectorCarrier=.*-13C rfBranchRxRef Equipment=1,AntennaUnitGroup=S3-TDD,RfBranch=1 Equipment=1,AntennaUnitGroup=S3-TDD,RfBranch=2 Equipment=1,AntennaUnitGroup=S3-TDD,RfBranch=3 Equipment=1,AntennaUnitGroup=S3-TDD,RfBranch=4 confbgs- Ericsson Internal INSTRUCTION Prepared (Subject resp) 25 (45) No. Adwin Wendi Zulfikar Approved (Document resp) Checked Date 2019-02-01 Rev Reference MOBILY MODERNIZATION deb SectorEquipmentFunction=S.-TDD deb EUtranCellTDD please make sure your final branch configuration should as below SAMPLE from FNI site power get SectorCarrier=.*-1.. configuredMaxTxPower Number TX/RX antenna per sector lhget SectorCarrier=.*-1.. noOfRxAntennas|noOfTxAntennas Configuration RX rf branch lget SectorCarrier=.*-1.. rfbranchR Ericsson Internal INSTRUCTION Prepared (Subject resp) 26 (45) No. Adwin Wendi Zulfikar Approved (Document resp) Checked Date 2019-02-01 Configuration TX rf branch lget SectorCarrier=.*-1.. rfbranchT Rev Reference MOBILY MODERNIZATION Ericsson Internal INSTRUCTION Prepared (Subject resp) 27 (45) No. Adwin Wendi Zulfikar Approved (Document resp) Checked Date Rev 2019-02-01 Reference MOBILY MODERNIZATION 3. SW level suppose as below so we need to upgrade it to this level LTE and NR same SW level = CXP9024418/15_R7C80 4. 5G baseline different that B41 you need to run as 2 script below - You still need to run 5G baseline from NPI team run /home/shared/common/ab_automation/tools/nr_health_check - After that you need to run our 5G baseline as below /home/shared/80075848/5G_BL_B41_RADIO4418_PH02 --- and choose no. 2 5. Please run below script for new MO at MTR20.Q1 LTE : /home/shared/80075848/GCellRelation_B41.mos NR : /home/shared/80075848/MOBILITY_NR_INTRA_B41.mos 6. Please make sure to set dl attenuation and delay same as per SAF on NR side. 7. Please make sure TDD pattern suppose as below 8. Make sure bfnoffset = 0 9. SC for B41 Radio 4418 scw RC18:1 scw RC34:1 scw RC35:1 scw RP136:20 scw RP137:20 scw RP138:20 scw RP78:61 Ericsson Internal INSTRUCTION Prepared (Subject resp) 28 (45) No. Adwin Wendi Zulfikar Approved (Document resp) Checked Date 2019-02-01 Rev Reference MOBILY MODERNIZATION Ericsson Internal INSTRUCTION Prepared (Subject resp) 29 (45) No. Adwin Wendi Zulfikar Approved (Document resp) Checked Date 2019-02-01 Rev Reference MOBILY MODERNIZATION ++++++++++++++++++++++++++++++++++++++++++++++ SCENARIO 03 New TDD baseband mixedmode AIR6449 with NR B41 ++++++++++++++++++++++++++++++++++++++++++++++ TDD PREPARATION: - Please take PRE-HC include KGET is must for existing LTE baseband since we need this kget to compare any radio parameter just incase new TDD baseband having degradation performance and store on our share folder - The process is the same with another scenario that you need to do 5G preparation first that mean traffic shifting on old LTE baseband + synch shifting + antenna shifting. - Please load new TDD script on ENM make sure there is no error during import and validating by ENM - After loading ZT-LMT by ASP please make sure to check on ENM that there is no error on all step and Integration completed. - Connectivity to AIR6449 will be DATA_1 for LTE and DATA_3 for NR Ericsson Internal INSTRUCTION Prepared (Subject resp) 30 (45) No. Adwin Wendi Zulfikar Approved (Document resp) Checked Date 2019-02-01 Rev Reference MOBILY MODERNIZATION - Try to connect to node and check status MME and all suppose enable, suppose MME define as existing and need to locked same exactly as existing LTE - Delete and recreate for PTP synch and synch-E confb+ gs+ Ericsson Internal INSTRUCTION Prepared (Subject resp) 31 (45) No. Adwin Wendi Zulfikar Approved (Document resp) Checked Date Rev 2019-02-01 Reference MOBILY MODERNIZATION bl RadioEquipmentClockReference=1 del RadioEquipmentClockReference=1 y ldel Ptp=1 y run /home/shared/80075848/PTP_ROUTER_TDD.mos st radio wait 4 st radio confbgs- - Check synch suppose RNT_TIME_LOCKED status - Make sure mixedmode radio is activated on all AIR6449 - You must change ptppathtimeerror to 750ns before upgrade SW set BoundaryOrdinaryClock=PTP_ROUTER,PtpBcOcPort=1 - Set mixedmode radio with AMOS deprecated - amos -v exclude_deprecated=1 NOXXXXX lt all set SectorEquipmentFunction mixedModeRadio true y q Set feature as below confb+ gs+ ptpPathTimeError 750 Ericsson Internal INSTRUCTION Prepared (Subject resp) 32 (45) No. Adwin Wendi Zulfikar Approved (Document resp) Checked Date 2019-02-01 set Lm=1,FeatureState=CXC4010319 FeatureState 1 set Lm=1,FeatureState=CXC4010613 FeatureState 1 set Lm=1,FeatureState=CXC4010616 FeatureState 1 set Lm=1,FeatureState=CXC4010618 FeatureState 1 set Lm=1,FeatureState=CXC4010620 FeatureState 1 set Lm=1,FeatureState=CXC4010717 FeatureState 1 set Lm=1,FeatureState=CXC4010723 FeatureState 1 set Lm=1,FeatureState=CXC4010770 FeatureState 1 set Lm=1,FeatureState=CXC4010856 FeatureState 1 set Lm=1,FeatureState=CXC4010912 FeatureState 1 set Lm=1,FeatureState=CXC4010956 FeatureState 1 set Lm=1,FeatureState=CXC4010959 FeatureState 1 set Lm=1,FeatureState=CXC4010961 FeatureState 1 set Lm=1,FeatureState=CXC4010973 FeatureState 1 set Lm=1,FeatureState=CXC4010974 FeatureState 1 set Lm=1,FeatureState=CXC4010990 FeatureState 1 set Lm=1,FeatureState=CXC4011033 FeatureState 1 set Lm=1,FeatureState=CXC4011034 FeatureState 1 set Lm=1,FeatureState=CXC4011050 FeatureState 1 set Lm=1,FeatureState=CXC4011055 FeatureState 1 set Lm=1,FeatureState=CXC4011059 FeatureState 1 set Lm=1,FeatureState=CXC4011061 FeatureState 1 set Lm=1,FeatureState=CXC4011064 FeatureState 1 set Lm=1,FeatureState=CXC4011075 FeatureState 1 set Lm=1,FeatureState=CXC4011157 FeatureState 1 set Lm=1,FeatureState=CXC4011183 FeatureState 1 set Lm=1,FeatureState=CXC4011245 FeatureState 1 set Lm=1,FeatureState=CXC4011247 FeatureState 1 set Lm=1,FeatureState=CXC4011251 FeatureState 1 set Lm=1,FeatureState=CXC4011252 FeatureState 1 set Lm=1,FeatureState=CXC4011253 FeatureState 1 set Lm=1,FeatureState=CXC4011258 FeatureState 1 set Lm=1,FeatureState=CXC4011317 FeatureState 1 set Lm=1,FeatureState=CXC4011319 FeatureState 1 set Lm=1,FeatureState=CXC4011326 FeatureState 1 set Lm=1,FeatureState=CXC4011327 FeatureState 1 set Lm=1,FeatureState=CXC4011345 FeatureState 1 set Lm=1,FeatureState=CXC4011346 FeatureState 1 set Lm=1,FeatureState=CXC4011366 FeatureState 1 set Lm=1,FeatureState=CXC4011370 FeatureState 1 set Lm=1,FeatureState=CXC4011372 FeatureState 1 set Lm=1,FeatureState=CXC4011373 FeatureState 1 set Lm=1,FeatureState=CXC4011378 FeatureState 1 set Lm=1,FeatureState=CXC4011443 FeatureState 1 set Lm=1,FeatureState=CXC4011476 FeatureState 1 set Lm=1,FeatureState=CXC4011482 FeatureState 1 set Lm=1,FeatureState=CXC4011485 FeatureState 1 set Lm=1,FeatureState=CXC4011515 FeatureState 1 set Lm=1,FeatureState=CXC4011554 FeatureState 1 set Lm=1,FeatureState=CXC4011559 FeatureState 1 set Lm=1,FeatureState=CXC4011710 FeatureState 1 set Lm=1,FeatureState=CXC4011713 FeatureState 1 set Lm=1,FeatureState=CXC4011714 FeatureState 1 set Lm=1,FeatureState=CXC4011802 FeatureState 1 set Lm=1,FeatureState=CXC4011813 FeatureState 1 set Lm=1,FeatureState=CXC4011815 FeatureState 1 set Lm=1,FeatureState=CXC4011823 FeatureState 1 set Lm=1,FeatureState=CXC4011911 FeatureState 1 set Lm=1,FeatureState=CXC4011913 FeatureState 1 set Lm=1,FeatureState=CXC4011914 FeatureState 1 set Lm=1,FeatureState=CXC4011918 FeatureState 1 Rev Reference MOBILY MODERNIZATION Ericsson Internal INSTRUCTION Prepared (Subject resp) 33 (45) No. Adwin Wendi Zulfikar Approved (Document resp) Checked Date Rev 2019-02-01 set Lm=1,FeatureState=CXC4011922 FeatureState 1 set Lm=1,FeatureState=CXC4011938 FeatureState 1 set Lm=1,FeatureState=CXC4011939 FeatureState 1 set Lm=1,FeatureState=CXC4011941 FeatureState 1 set Lm=1,FeatureState=CXC4011943 FeatureState 1 set Lm=1,FeatureState=CXC4011946 FeatureState 1 set Lm=1,FeatureState=CXC4011951 FeatureState 1 set Lm=1,FeatureState=CXC4011955 FeatureState 1 set Lm=1,FeatureState=CXC4011969 FeatureState 1 set Lm=1,FeatureState=CXC4011973 FeatureState 1 set Lm=1,FeatureState=CXC4011983 FeatureState 1 set Lm=1,FeatureState=CXC4011996 FeatureState 1 set Lm=1,FeatureState=CXC4011999 FeatureState 1 set Lm=1,FeatureState=CXC4012002 FeatureState 1 set Lm=1,FeatureState=CXC4012003 FeatureState 1 set Lm=1,FeatureState=CXC4012018 FeatureState 1 set Lm=1,FeatureState=CXC4012051 FeatureState 1 set Lm=1,FeatureState=CXC4012070 FeatureState 1 set Lm=1,FeatureState=CXC4012097 FeatureState 1 set Lm=1,FeatureState=CXC4012162 FeatureState 1 set Lm=1,FeatureState=CXC4012218 FeatureState 1 set Lm=1,FeatureState=CXC4012240 FeatureState 1 set Lm=1,FeatureState=CXC4012257 FeatureState 1 set Lm=1,FeatureState=CXC4012259 FeatureState 1 set Lm=1,FeatureState=CXC4012269 FeatureState 1 set Lm=1,FeatureState=CXC4040005 FeatureState 1 set Lm=1,FeatureState=CXC4040008 FeatureState 1 set Lm=1,FeatureState=CXC4040016 FeatureState 1 set FeatureState=CXC4011018 featureState 1 set CXC4040011 featureState 0 set CXC4040007 featureState 0 set CXC4012162 featureState 0 confbgs- - Check enbID suppose start from 42XXXX --- > 42sideID - Check how many cells define and sector define suppose same as existing. Reference MOBILY MODERNIZATION Ericsson Internal INSTRUCTION Prepared (Subject resp) 34 (45) No. Adwin Wendi Zulfikar Approved (Document resp) Checked Date 2019-02-01 - Power on all cell suppose 40watt - Check NTPsever suppose define Rev Reference MOBILY MODERNIZATION Ericsson Internal INSTRUCTION Prepared (Subject resp) 35 (45) No. Adwin Wendi Zulfikar Approved (Document resp) Checked Date 2019-02-01 Rev Reference MOBILY MODERNIZATION - Check relation and suppose all define pr ,EUtranFreqRelation= pr ,GeranFreqGroupRelation= pr ,UtranFreqRelation= - Run below command to avoid missing relation define - Run 4G TDD baseline and remember you need to specify which city you integrated for TDD run /home/shared/common/ab_automation/tools/lte_HC_EnodeB run /home/shared/80075938/ejuguan/scripts/create_LTE_234G_relation_1825_1850_326_6350_37950_40392_40194_39994_39796.mos please choose as below Jeddah is no 5 makkah is no 6 taif is no 9 - Set timeandphase set . timeAndPhaseSynchAlignment true you will find 2 script, .mos and .mosi for .mosi you need to modify inside the script so script can be run properly Ericsson Internal INSTRUCTION Prepared (Subject resp) 36 (45) No. Adwin Wendi Zulfikar Approved (Document resp) Checked Date Rev 2019-02-01 Reference MOBILY MODERNIZATION /ericsson/log/amos/moshell_logfiles/80075848/logs_moshell/diff/20200617/LTJD5755_023126.mos /ericsson/log/amos/moshell_logfiles/80075848/logs_moshell/diff/20200617/LTJD5755_023526.mosi For .mosi script you need to delete some part as below seti EUtranCellTDD=5755-11B,UeMeasControl=1,ReportConfigEUtraBestCell=1$ reportAmountA3 8 seti EUtranCellTDD=5755-11B,UeMeasControl=1,ReportConfigEUtraBestCell=1$ reportIntervalA3 1 (MS_240) --- need to delete seti EUtranCellTDD=5755-11B,UeMeasControl=1,ReportConfigEUtraBestCell=1$ reportQuantityA3 0 (SAME_AS_TRIGGER_QUANTITY) --- need to delete and please run both script after you modify .mosi script - Make sure PCI and rach and some parameter is MUST same as existing TDD hget ENodeBFunction=1,EUtranCellTDD= ^CellId$|^physicalLayerCellIdGroup$|^physicalLayerSubCellId$| ^physicalLayerCellId$|^tac$|^earfcn$|rachRootSequence Ericsson Internal INSTRUCTION Prepared (Subject resp) 37 (45) No. Adwin Wendi Zulfikar Approved (Document resp) Checked Date 2019-02-01 Rev Reference MOBILY MODERNIZATION Please ask ASP to remove RET connection from existing TDD radio to L2100 Radio and please do reconfiguration as below for this change ** step how to change RET control from Radio TDD to L2100 Radio 1. Check which radio no. having 2100 ERS. hget field prod (RRU-/7/9/11) this case 2. Check 2100 Radio having Port R define and in enabled state or not. st rfport 3. Else need to add 2100 RF port and unlock them. Cr Equipment=1,FieldReplaceableUnit=RRU-7,RfPort=R Cr Equipment=1,FieldReplaceableUnit=RRU-9,RfPort=R Cr Equipment=1,FieldReplaceableUnit=RRU-11,RfPort=R 4. Replace the Near unit rfport reference with 2100 radio R port. Ericsson Internal INSTRUCTION Prepared (Subject resp) 38 (45) No. Adwin Wendi Zulfikar Approved (Document resp) Checked Date Rev 2019-02-01 Reference MOBILY MODERNIZATION Status before change RRU-13/14/15 TDD radio R port Status after change RRU-7/9/11 2100 radio R port Below is script but please make sure L2100 Radio is same position slot set AntennaUnitGroup=S1-1800,AntennaNearUnit=1 rfPortRef FieldReplaceableUnit=RRU-7,RfPort=R set AntennaUnitGroup=S1-2100,AntennaNearUnit=1 rfPortRef FieldReplaceableUnit=RRU-7,RfPort=R set AntennaUnitGroup=S1-800,AntennaNearUnit=RET_800_900 rfPortRef FieldReplaceableUnit=RRU-7,RfPort=R set AntennaUnitGroup=S1-TDD,AntennaNearUnit=1 rfPortRef FieldReplaceableUnit=RRU-7,RfPort=R set AntennaUnitGroup=S1-TDD,AntennaNearUnit=2 rfPortRef FieldReplaceableUnit=RRU-7,RfPort=R set AntennaUnitGroup=S2-1800,AntennaNearUnit=1 rfPortRef FieldReplaceableUnit=RRU-9,RfPort=R set AntennaUnitGroup=S2-2100,AntennaNearUnit=1 rfPortRef FieldReplaceableUnit=RRU-9,RfPort=R set AntennaUnitGroup=S2-800,AntennaNearUnit=RET_800_900 rfPortRef FieldReplaceableUnit=RRU-9,RfPort=R set AntennaUnitGroup=S2-TDD,AntennaNearUnit=1 rfPortRef FieldReplaceableUnit=RRU-9,RfPort=R set AntennaUnitGroup=S2-TDD,AntennaNearUnit=2 rfPortRef FieldReplaceableUnit=RRU-9,RfPort=R set AntennaUnitGroup=S3-1800,AntennaNearUnit=1 rfPortRef FieldReplaceableUnit=RRU-11,RfPort=R set AntennaUnitGroup=S3-2100,AntennaNearUnit=1 rfPortRef FieldReplaceableUnit=RRU-11,RfPort=R set AntennaUnitGroup=S3-800,AntennaNearUnit=RET_800_900 rfPortRef FieldReplaceableUnit=RRU-11,RfPort=R set AntennaUnitGroup=S3-TDD,AntennaNearUnit=1 rfPortRef FieldReplaceableUnit=RRU-11,RfPort=R set AntennaUnitGroup=S3-TDD,AntennaNearUnit=2 rfPortRef FieldReplaceableUnit=RRU-11,RfPort=R Ericsson Internal INSTRUCTION Prepared (Subject resp) 39 (45) No. Adwin Wendi Zulfikar Approved (Document resp) Checked Date Rev 2019-02-01 Reference MOBILY MODERNIZATION 5. After rfport correction on nearunit need baseband to be restart. No need to change uniqueid/electrical tilt. Node get comes up with RET enabled(else team need to TS from site end), need RET to be calibrate. (acc RetSubUnit=1 forceCalibration) After reset & before calibration status. After calibration successful done, create the cv. Failed case should report to field team. - Define externalnode and make sure port is same as connected by ASP Please upgrade SW level as below but please make sure AIR6449 is connected on power ON CXP9024418/12_R70B21 20.Q3 - Please unlocked cell TDD on new baseband for 1 ROP and run all below script confb+ gs+ run /home/shared/common/ab_automation/tools/lte_Define_UL_Comp run /home/shared/common/ab_automation/tools/lte_Define_sCells run /home/shared/common/ab_automation/tools/lte_Define_PmUeMeas run /home/shared/common/ab_automation/tools/lte_Define_LoadBalancing run /home/shared/common/ab_automation/tools/lte_define_co_relations y Ericsson Internal INSTRUCTION Prepared (Subject resp) 40 (45) No. Adwin Wendi Zulfikar Approved (Document resp) Checked Date 2019-02-01 Rev Reference MOBILY MODERNIZATION run /home/shared/common/ab_automation/tools/lte_CoLoc_sleepModeCovCellCandidate_allowed run /home/shared/common/ab_automation/tools/lte_CoLoc_isRemoveAllowed_false - Please check RSSI pmxet cell Int_RadioRecInterferencePucchPwr$ - Please run M-MIMO parameter as below confb+ gs+ lset Lm=1,FeatureState=CXC4010609$ featureState 0 lset Lm=1,FeatureState=CXC4011056$ featureState 0 lset Lm=1,FeatureState=CXC4011074$ featureState 0 lset Lm=1,FeatureState=CXC4011255$ featureState 0 lset Lm=1,FeatureState=CXC4011326$ featureState 1 lset Lm=1,FeatureState=CXC4011427$ featureState 0 lset Lm=1,FeatureState=CXC4011667$ featureState 0 lset Lm=1,FeatureState=CXC4011996$ featureState 1 lset Lm=1,FeatureState=CXC4012271$ featureState 0 lset Lm=1,FeatureState=CXC4012390$ featureState 1 lset Lm=1,FeatureState=CXC4012257$ featureState 1 lset Lm=1,FeatureState=CXC4011264$ featureState 0 lset Lm=1,FeatureState=CXC4011803$ featureState 0 lset Lm=1,FeatureState=CXC4011982$ featureState 0 lset EUtranCellTDD=.* transmissionMode 8 lset EUtranCellTDD=.* dlMaxMuMimoLayers 0 lset EUtranCellTDD=.* ulMaxMuMimoLayers 4 lset EUtranCellTDD=.* tm7ModeSwitchingEnabled true lset EUtranCellTDD=.* tm8ModeSwitchingEnabled true lset EUtranCellTDD=.* ulSrsEnable false scw 2197:900 scw 2200:900 scw 3398:5 scw 3549:0 scw 3719:100 confbgs- - Make sure bfnoffset = 0 - Check Ping to MME and SGW Run /home/shared/80075848/FLOW/check_SGW - Please running 5G baseline and anchoring to NR for OLD baseband LOxx as well as LTxx with below baseline Choose no 2 for LTE Massive MIMO --- for LTJDXXX ( new baseband ) Choose no 1 for old baseband ---- LOJDXXXX Ericsson Internal INSTRUCTION Prepared (Subject resp) 41 (45) No. Adwin Wendi Zulfikar Approved (Document resp) Checked Date 2019-02-01 - Rev Reference MOBILY MODERNIZATION Please delete TDD cell on legacy baseband ( old baseband ), make sure to make CV ( cvms b4DEL_TDD_5G ) confb+ gs+ $date = `date +%d%m%y` cvms b4DEL_TDD_5G_$date bl EUtranCellTDD $siteID = $nodename -s [A-Z][A-Z][A-Z][A-Z] ldel EUtranCellTDD=$siteID-1..,GUtranFreqRelation y ldel EUtranCellTDD=$siteID-1..,EUtranFreqRelation y Ericsson Internal INSTRUCTION Prepared (Subject resp) 42 (45) No. Adwin Wendi Zulfikar Approved (Document resp) Checked Date 2019-02-01 ldel EUtranCellTDD=$siteID-1..,UtranFreqRelation y ldel EUtranCellTDD=$siteID-1..,GeranFreqGroupRelation y ldel EUtranCellRelation=4203-22$siteID-2.$ y ldel EUtranCellRelation=4203-22$siteID-3.$ y ldel EUtranCellRelation=4203-22$siteID-5.$ y ldel EUtranCellTDD=$siteID-1.. y confbgscvms AFDEL_TDD_5G_$date lt all st cell NR PREPARATION: - Delete create for PTP and synch E confb+ gs+ bl RadioEquipmentClockReference=PTP_ROUTER del RadioEquipmentClockReference=PTP_ROUTER y ldel Ptp=1 y run /home/shared/eadwwen/PTP_ROUTER.mos st radio wait 4 st radio confbgs- - Check synch suppose RNT_TIME_LOCKED status - Make sure mixedmode radio is activated on all AIR6449 Rev Reference MOBILY MODERNIZATION Ericsson Internal INSTRUCTION Prepared (Subject resp) 43 (45) No. Adwin Wendi Zulfikar Approved (Document resp) Checked Date Rev 2019-02-01 - MOBILY MODERNIZATION You must change ptppathtimeerror to 750ns before upgrade SW set BoundaryOrdinaryClock=PTP_ROUTER,PtpBcOcPort=1 - Reference ptpPathTimeError 750 Set MIMO feature set CXC4012272 featureState 1 - Set mixedmode radio with AMOS deprecated - amos -v exclude_deprecated=1 NOXXXXX lt all set SectorEquipmentFunction mixedModeRadio true y q Set for mixedmode radio feature set FeatureState=CXC4012307 featureState 1 - SW level suppose as below so we need to upgrade it to this level LTE and NR same SW level = CXP9024418/12_R70B21 20.Q3 - 5G baseline as same as B41 you need to run as 2 script below You still need to run 5G baseline from NPI team run /home/shared/common/ab_automation/tools/nr_health_check After that you need to run our 5G baseline as below /home/shared/80075848/5G_BL_B41_RADIO4418_PH02 --- and choose no. 3 Ericsson Internal INSTRUCTION Prepared (Subject resp) 44 (45) No. Adwin Wendi Zulfikar Approved (Document resp) Checked Date 2019-02-01 - Rev Reference MOBILY MODERNIZATION Please run below script for new MO at MTR20.Q3 LTE exiting and new TDD ( LOXX and LTXX ) : /home/shared/80075848/GCellRelation_B41.mos NR : /home/shared/80075848/MOBILITY_NR_INTRA_B41.mos - Please make sure TDD pattern suppose as below - Make sure bfnoffset = 0 - SC for B41 AIR6449 scw RC18:1 Ericsson Internal INSTRUCTION Prepared (Subject resp) 45 (45) No. Adwin Wendi Zulfikar Approved (Document resp) Checked Date Rev 2019-02-01 scw RC34:1 scw RC35:1 scw RP136:20 scw RP137:20 scw RP138:20 scw RP78:61 - Define external node based ASP port information Check ping to SGW and MME Please define 5G baseline and anchoring to both LTE : LOXX and LTXX Reference MOBILY MODERNIZATION
0
You can add this document to your study collection(s)
Sign in Available only to authorized usersYou can add this document to your saved list
Sign in Available only to authorized users(For complaints, use another form )