101674064 101674064 FLORIDA BUILDING Eighth Edition CODE (2023) Accessibility Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 2012 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION ADOPTED PURSUANT TO SECTION 553.503, FLORIDA STATUTES BASED ON THE 2010 ADA STANDARDS FOR ACCESSIBLE DESIGN Item No. 5603L23 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 Florida Building Code, Accessibility, 8th Edition (2023) First Printing: July 2023 ISBN: 978-1-960701-24-4 (loose leaf edition) ISBN: 978-1-960701-25-1 (PDF download) PRINTED IN THE USA T029077 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 PREFACE The 1993 Florida Legislature enacted the “Florida Americans with Disability Accessibility Implementation Act” which incorporated the architectural accessibility requirements of the Americans with Disabilities Act of 1990, Public Law No. 101-336, 42 U.S.C. Section 12101 et. seq. ADA, into Florida law and maintained existing provisions of Florida law thought to be more stringent than the ADA accessibility guidelines. In 1997 the legislature amended the Act to address U.S. Department of Justice (DOJ) concerns with Florida requirements, which might not have been equivalent or more stringent than ADA architectural standards, to obtain federal certification of Florida’s building code as substantially equivalent to the Federal ADA Standards for Accessible Design as adopted by the Department of Justice (DOJ) in 28 CFR 36. The United States Access Board adopted revised ADA Accessibility Guidelines in 2004. DOJ published final regulations September 15, 2010 adopting the 2004 Guidelines with additions pursuant to 28 CFR 35 and 28 CFR 36 as the 2010 ADA Standards for Accessible Design. The Florida Building Commission updated the Florida Accessibility Code for Building Construction for consistency with the 2010 ADA Standards and Florida law, Part II, Chapter 553, Florida Statutes, in the summer of 2011. The intent as established by s.553.502, Florida Statutes, is to maintain the US Department of Justice certification of the Code as substantially equivalent to the ADA Standards so compliance with the Code provides presumption of compliance with the ADA Standards. The 1997 Florida Accessibility Code for Building Construction was certified by DOJ, however, the 2012 Florida Accessibility Code for Building Construction must also be reviewed and certified by DOJ. Until the review is completed and DOJ notifies the State the 2012 Code is certified all parties should maintain due diligence to ensure compliance with both the 2010 ADA Standards for Accessible Design and the 2012 Florida Accessibility Code. Note: Code certification provides presumption of rebuttable evidence of compliance with the ADA for private entities (Title III entities) but not public entities (Title II entities). Accessibility is a multifaceted issue within the issues of life today. The legislative actions of the 101st Congress which implemented the Americans with Disabilities Act of 1990 and previous acts of the Florida Legislature have been combined in the following pages to reflect accessibility laws as they relate to most areas of construction in Florida. Areas of employment as related to accessibility and/or complaints would be the responsibility of the Equal Employment Opportunity Commission, 1-800-669-4000 or 305-5364491. Primarily because of the complexities of balancing the rights of the physically disabled and the technically specific requirements of the built environment, no single agency has been charged with enforcement of all issues pertaining to accessibility. The following is a listing of agencies and their statutory areas of responsibility for accessibility. A thorough attempt was made by the Florida Building Commission at the time of publication of this code to ensure that this manual is a reflection of the laws of Florida and the administrative rules of each agency as these requirements relate to construction. Because individual agency rules may change, it is the responsibility of the design professional and the property owner to ensure compliance with subsequent revisions. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION iii Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 RESPONSIBLE AGENCIES 1. H.U.D. Office of Fair Housing and Equal Opportunity Hot Line Washington, D.C. Voice: 202-708-1112 TTY: 202-708-1455 www.hud.gov Atlanta, GA Voice: 1-404-331-5136 Forms and Publications 1-800-767-7468 Florida Offices Jacksonville Voice: 1-904-232-2627 FAX: 1-904-232-3759 Miami Voice: 1-305-536-5678 FAX: 1-305-536-5765 TTY: 1-305-536-4734 Orlando Voice: 1-407-648-6441 FAX: 1-407-648-6310 Tampa Voice: 1-813-228-2026 FAX: 1-813-228-2431 TTY: 1-813-228-2115 2. Florida Commission on Human Relations Voice: 1-850-488-7082 Voice Message Service: 1-800-342-8170 TDD ASCII 1-800-955-1339 TDD Baudot 1-800-955-8771 Voice Relay Service: 1-800-955-8770 fchr.state.fl.us 3. Public Telephone Installation and Placement: Florida Public Service Commission Voice: 1-800-342-3552 Fax: 1-850-511-0809 TDD: 1-800-955-8771 www.floridapsc.com 6. Elevator Accessibility: Department of Business Regulation Bureau of Elevator Inspection Automated Call System: 1-850-487-1395, select Hotels & Restaurants, then Elevators www.myfloridalicense.com/dbpr/hr/ elevators.html 7. Florida Government Facilities: Department of Management Services Division of Real Estate Development and Management Voice: 1-850-488-2074 www.dms.myflorida.com/business_operations real_estate_development_management 8. Hospital and Health Care Facilities: Agency for Health Care Administration Office of Plans and Construction Voice: 1-850-412-4477 www.AHCA.myflorida.com/MCHQ/plans/ 9. Public Schools and State Universities: Florida Department of Education Office of Educational Facilities www.fldoe.org/edfacil/ Voice: 1-850-245-0494 Fax: 1-850-245-9236 www.firn.edu/doe/edfacil/ 10. State Prisons: Department of Corrections Facilities Services Voice: 1-850-487-1330 www.dc.state.fl.us/facilities 4. Government Parking Facilities: Florida Department of Transportation Traffic Operations Office Voice: 1-866-374-3368, ext. 5253 FAX: 1-850-414-5251 TDD: 1-850-921-0762 iv 5. Accessible Parking Placards: Department of Highway Safety and Motor Vehicles Contact your local Tax Collector's Office. Contact numbers listed by county at: www.hsmv.state.fl.us/offices/ 11. ADA Questions and Complaints: United States Department of Justice Voice: 1-800-514-0301 (select option 7 for technical assistance) TTY/TDD: 1-800-514-0383 www.usdoj.gov/disabilities.htm FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 12. Florida Accessibility Code and Waiver Questions/Direction to Additional Resources: Florida Building Commission Voice: See Commission Website FAX: See Commission Website www.FloridaBuilding.org 14. Code Compliance and Enforcement: Local Building Departments 13. Historic Preservation: Office of Cultural and Historical Resources Division of Historical Resources Florida Department of State Voice: 1-850-245-6372 FAX: 1-850-245-6437 dhr.dos.state.fl.us/preservation FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION v Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 553.513 Enforcement. It shall be the responsibility of each local government and each code enforcement agency established pursuant to Section 553.80 to enforce the provisions of this part. This act expressly preempts the establishment of handicapped accessibility standards to the state and supersedes any county or municipal ordinance on the subject. However, nothing in this section shall prohibit municipalities and counties from enforcing the provisions of this act. History.—s. 6, ch. 89-97; s. 2, ch. 93-183. Note.—Former s. 553.495. Department of Business and Professional Regulation 553.75(3) The department shall be responsible for the provision of administrative and staff-support services relating to the functions of the commission. With respect to matters within the jurisdiction of the commission, the department shall be responsible for the implementation and faithful discharge of all decisions of the commission made pursuant to its authority under the provisions of this part. The department is authorized to use communications media technology in conducting meetings of the commission or any meetings held in conjunction with meetings of the commission. Florida Building Commission 553.506 Powers of the commission. In addition to any other authority vested in the Florida Building Commission by law, the commission, in implementing this part, may, by rule, adopt revised and updated versions of the Americans with Disabilities Act Standards for Accessible Design in accordance with Chapter 120. 553.512 Modifications and waivers; advisory council. The Florida Building Commission shall provide by regulation criteria for granting individual modifications of, or exceptions from, the literal requirements of this part upon a determination of unnecessary, unreasonable, or extreme hardship, provided such waivers shall not violate federal accessibility laws and regulations and shall be reviewed by the Accessibility Advisory Council vi (see Section 553.512, Florida Statutes). (1) Notwithstanding any other provision of this subsection if an applicant for a waiver demonstrates economic hardship in accordance with 28 C.F.R. s. 36.403(f)(1), a waiver shall be granted. The commission may not consider waiving any of the requirements of Section 553.5041 unless the applicant first demonstrates that he or she has applied for and been denied waiver or variance from all local government zoning, subdivision regulations, or other ordinances that prevent compliance therewith. Further, the commission may not waive the requirement of Section 553.5041(5)(a) and (c)1 governing the minimum width of accessible routes and minimum width of accessible parking spaces. (2) The Accessibility Advisory Council shall consist of the following seven members, who shall be knowledgeable in the area of accessibility for persons with disabilities. The secretary of community affairs shall appoint the following: a representative from the Advocacy Center for Persons with Disabilities, Inc.; a representative from the Division of Blind Services; a representative from the Division of Vocational Rehabilitation; a representative from a statewide organization representing the physically handicapped; a representative from the hearing impaired; a representative from the president, Florida Council of Handicapped Organizations; and a representative of the Paralyzed Veterans of America. The terms for the first three council members appointed subsequent to October 1, 1991, shall be four years; the terms for the next two council members appointed shall be for three years; and the terms for the next two members shall be for two years. Thereafter, all council member appointments shall be for terms of four years. No council member shall serve more than two four-year terms subsequent to October 1, 1991. Any member of the council may be replaced by the secretary upon three unexcused absences. Upon application made in the form provided, an individual waiver or modification may be granted by the commission so long as such modification or waiver is not in conflict with more stringent standards provided in another chapter. (3) Members of the council shall serve without FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 compensation, but shall be entitled to reimbursement for per diem and travel expenses as provided by Section 112.061. constitute rebuttable evidence the facility has been constructed or altered in accordance with the minimum accessibility requirements of the ADA. (4) Meetings of the advisory council shall be held in conjunction with the regular meetings of the commission. History.—s. 3, ch. 78-333; s. 1, ch. 82-46; s. 2, ch. 83-265; s. 25, ch. 86-220; s. 5, ch. 89-97; ss. 1, 5, 6, ch. 91-172; s. 5, ch. 91-429; s. 2, ch. 93-183; s. 10, ch. 97-76; s. 68, ch. 2000-141; s. 61, ch. 2000154; s. 13, ch. 2002-293. Background shaded text and blue print text indicate changes to the 2004 ADA Accessibility Guidelines (ADAAG). Requirements based on Florida law are indicated by gray background shading. Requirements based on the U.S. Department of Justice regulations 28 CFR, Part 35 and 28 CFR, Part 36 and the U.S. Department of Transportation regulation 49 CFR, Part 37 are indicated in blue print. Florida Law Federal ADA Rules The Florida Accessibility Code for Building Construction is established by Florida law, Part II, Chapter 553, Florida Statutes, (Sections 553.501 553.513, Florida Statutes). The law was amended in 2011 and its resulting requirements are integrated into this code. The revisions are established by chapter 2011-222, Laws of Florida. Laws of Florida and Florida Statutes can be accessed through the Florida Department of State, Division of Library & Information Sciences web site http://dlis.dos.state.fl.us/fgils/government.html. US Department of Justice 2010 ADA Standards for Accessible Design http://www.ada.gov/2010ADAstandards_ index.htm US Department of Transportation ADA Standards for Transportation Facilities http://www.access-board.gov/ada-aba/adastandards-dot.cfm Waivers The Florida Building Commission may waive Florida specific requirements of this code. It does not waive requirements of this code to standards below the federal ADA standards on which it is based. Applications for waiver and the criteria for their review are established by Rule Chapter 9N-4, Florida Administrative Code. Current versions of the Rule can be accessed through the Florida Department of State web site http://dlis.dos.state.fl.us/fgils/government.html. Applications can be found on the Florida Building Commission web site www.FloridaBuilding.org. General Notes If an official either waives an accessible element or feature or allows a change that does not provide equivalent facilitation, the fact that the Department of Justice has certified the code itself will not FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION vii Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 viii FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 TABLE OF CONTENTS Chapter 1: Application and Administration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 101 Purpose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 102 Dimensions for Adults and Children . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 103 Equivalent Facilitation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 104 Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 105 Referenced Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 106 Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Chapter 2: Scoping Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 201 Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 202 Existing Buildings and Facilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 203 General Exceptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 204 Protruding Objects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 205 Operable Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 206 Accessible Routes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 207 Accessible Means of Egress . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 208 Parking Spaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 209 Passenger Loading Zones and Bus Stops . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 210 Stairways . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 211 Drinking Fountains . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 212 Kitchens, Kitchenettes, and Sinks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 213 Toilet Facilities and Bathing Facilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 214 Washing Machines and Clothes Dryers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 215 Fire Alarm Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 216 Signs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 217 Telephones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 218 Transportation Facilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 219 Assistive Listening Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 220 Automatic Teller Machines and Fare Machines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 221 Assembly Areas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 222 Dressing, Fitting, and Locker Rooms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 223 Medical Care and Long-Term Care Facilities. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 224 Transient Lodging Guest Rooms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 225 Storage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 226 Dining Surfaces and Work Surfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION ix Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 TABLE OF CONTENTS 227 Sales and Service. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 228 Depositories, Vending Machines, Change Machines, Mail Boxes, and Fuel Dispensers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 229 Windows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 230 Two-Way Communication Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 231 Judicial Facilities. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 232 Detention Facilities and Correctional Facilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 233 Residential Facilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 234 Amusement Rides . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 235 Recreational Boating Facilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 236 Exercise Machines and Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 237 Fishing Piers and Platforms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 238 Golf Facilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 239 Miniature Golf Facilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 240 Play Areas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 241 Saunas and Steam Rooms. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 242 Swimming Pools, Wading Pools, and Spas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 243 Shooting Facilities with Firing Positions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 Chapter 3: Building Blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .61 301 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 302 Floor or Ground Surfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 303 Changes in Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62 304 Turning Space . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 305 Clear Floor or Ground Space . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 306 Knee and Toe Clearance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 307 Protruding Objects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 308 Reach Ranges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 309 Operable Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 Chapter 4: Accessible Routes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71 401 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 402 Accessible Routes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 403 Walking Surfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 404 Doors, Doorways, and Gates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72 405 Ramps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 406 Curb Ramps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81 407 Elevators. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84 x FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 TABLE OF CONTENTS 408 Limited-Use/Limited-Application Elevators. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92 409 Private Residence Elevators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94 410 Platform Lifts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95 Chapter 5: General Site and Building Elements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .97 501 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97 502 Parking Spaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97 503 Passenger Loading Zones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 504 Stairways . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101 505 Handrails . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102 Chapter 6: Plumbing Elements and Facilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .107 601 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107 602 Drinking Fountains . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107 603 Toilet and Bathing Rooms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107 604 Water Closets and Toilet Compartments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108 605 Urinals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115 606 Lavatories and Sinks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116 607 Bathtubs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117 608 Shower Compartments. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119 609 Grab Bars . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124 610 Seats . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126 611 Washing Machines and Clothes Dryers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127 612 Saunas and Steam Rooms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128 Chapter 7: Communication Elements and Features . . . . . . . . . . . . . . . . . . . . . . . . . . . .129 701 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129 702 Fire Alarm Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129 703 Signs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129 704 Telephones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 135 705 Detectable Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136 706 Assistive Listening Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137 707 Automatic Teller Machines and Fare Machines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137 708 Two-Way Communication Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140 Chapter 8: Special Rooms, Spaces and Elements . . . . . . . . . . . . . . . . . . . . . . . . . . . . .141 801 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141 802 Wheelchair Spaces, Companion Seats, and Designated Aisle Seats . . . . . . . . . . . . . 141 803 Dressing, Fitting, and Locker Rooms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION xi Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 TABLE OF CONTENTS 804 Kitchens and Kitchenettes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144 805 Medical Care and Long-Term Care Facilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 146 806 Transient Lodging Guest Rooms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 146 807 Holding Cells and Housing Cells . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148 808 Courtrooms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148 809 Residential Dwelling Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148 810 Transportation Facilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150 811 Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 153 Chapter 9: Built-In Elements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .155 901 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155 902 Dining Surfaces and Work Surfaces. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155 903 Benches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155 904 Check-Out Aisles and Sales and Service Counters . . . . . . . . . . . . . . . . . . . . . . . . . . . 156 Chapter 10: Recreation Facilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .159 1001 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 159 1002 Amusement Rides . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 159 1003 Recreational Boating Facilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 161 1004 Exercise Machines and Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 166 1005 Fishing Piers and Platforms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 166 1006 Golf Facilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 167 1007 Miniature Golf Facilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 168 1008 Play Areas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 169 1009 Swimming Pools, Wading Pools, and Spas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 173 1010 Shooting Facilities with Firing Positions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 180 List of Figures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .181 xii FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 1: APPLICATION AND ADMINISTRATION 101 PURPOSE 101.1 General. This code contains scoping and technical requirements for accessibility to sites, facilities, buildings, and elements by individuals with disabilities. The requirements are to be applied during the design, construction, additions to, and alteration of sites, facilities, buildings, and elements. Advisory 101.1 General. In addition to the 2004 ADAAG requirements, covered entities must comply with the regulations issued by the Department of Justice and the Department of Transportation under the Americans with Disabilities Act. The Department of Justice regulations 28 CFR, Part 35 and 28 CFR, Part 36, the Department of Transportation 49 CFR, Part 37 and the requirements of Florida law Part II, chapter 553, F.S. have been incorporated in this code. This code is adopted as part of the Florida Building Code by law, s.553.73(1)(a), Florida Statutes. The administrative requirements of the Florida Building Code, Building, Chapter 1 not specifically addressed by this code apply to construction necessary to comply with this code, e.g. permitting, construction documents, plans review and inspections, etc. 101.1.1 This code shall take effect March 15, 2012. After July 1, 2011 and prior to March 15, 2012 this code may be used to comply with chapter 2011-222, section 29, Laws of Florida. 101.1.2 All new or altered public buildings and facilities, private buildings and facilities, places of public accommodation, and commercial facilities subject to this code shall comply with this code. 101.1.3 This code establishes standards for accessibility to places of public accommodation and commercial facilities by individuals with disabilities. This code shall also apply: to state and local government facilities pursuant to Section 553.503, F.S.; to private clubs pursuant to Section 553.505, F.S.; and to residential buildings pursuant to Section 553.504(2), F.S., and the ADA Standards for Accessible Design. It is to be applied during the design construction and alteration of such buildings and facilities as required by this code. 101.1.4 This code is not intended to expand or diminish the defenses available to a place of public accommodation or a commercial facility under the Americans with Disabilities Act and the ADA Standards for Accessible Design, including, but not limited to, the readily achievable standard, and the standards applicable to alterations to places of public accommodation and commercial facilities. 101.2 Effect on Removal of Barriers in Existing Facilities. Removal of architectural barriers, pursuant to 28 C.F.R. s. 36.304, from buildings, structures or facilities shall comply with this code’s requirements for alterations unless compliance would render the removal not readily achievable. In no instance shall the removal of an architectural barrier create a significant risk to the health or safety of an individual with a disability or others. This code applies to alterations to existing facilities that are subject to the barrier removal requirement under Title III of the ADA to the extent required by regulations issued by the Department of Justice incorporated in 202.6.1 and to alterations undertaken by Title II entities to provide program access. This document does not address existing facilities unless altered at the discretion of a covered entity. The Department of Justice has authority over existing facilities that are subject to the requirement for removal of barriers under Title III of the ADA. Any determination that this document applies to existing facilities subject to the barrier removal requirement is solely within the discretion of the Department of Justice and is effective only to the extent required by regulations issued by the Department of Justice. 102 DIMENSIONS FOR ADULTS AND CHILDREN The technical requirements are based on adult dimensions and anthropometrics. In addition, this code includes technical requirements based on children’s dimensions and anthropometrics for drinking fountains, water closets, toilet compartments, lavatories and sinks, dining surfaces, and work surfaces. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 1 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 1: APPLICATION AND ADMINISTRATION SCOPING 103 EQUIVALENT FACILITATION Nothing in these requirements prevents the use of designs, products, or technologies as alternatives to those prescribed, provided they result in substantially equivalent or greater accessibility and usability. Departure from the explicit technical and scoping requirements of this code for any element voids any otherwise applicable presumption of rebuttable evidence that the element has been constructed or altered in accordance with the minimum accessibility requirements of the ADA. Advisory 103 Equivalent Facilitation. The responsibility for demonstrating equivalent facilitation in the event of a challenge rests with the covered entity. With the exception of transit facilities, which are covered by regulations issued by the Department of Transportation, there is no process for certifying that an alternative design provides equivalent facilitation. US Department of Justice “certification” of the Florida Accessibility Code as substantially equivalent to the ADA Standards for Accessible Design means the code meets or exceeds the minimum requirements of Title III of the ADA for accessibility and usability of facilities covered by Title III. Certification provides private entities, complying with the Florida code a “presumption of rebuttable evidence” of compliance with the ADA Title III regulations. However, the “presumption” applies only if the explicit requirements of the code are met. Equivalent Facilitation is authorized for alternate methods of providing accessibility but those alternate methods will not be afforded the “presumption.” 104 CONVENTIONS 104.1 Dimensions. Dimensions that are not stated as “maximum” or “minimum” are absolute. 104.1.1 Construction and Manufacturing Tolerances. All dimensions are subject to conventional industry tolerances except where the requirement is stated as a range with specific minimum and maximum end points. Advisory 104.1.1 Construction and Manufacturing Tolerances. Conventional industry tolerances recognized by this provision include those for field conditions and those that may be a necessary consequence of a particular manufacturing process. Recognized tolerances are not intended to apply to design work. It is good practice when specifying dimensions to avoid specifying a tolerance where dimensions are absolute. For example, if this code requires “1 inches,” avoid specifying “1 inches plus or minus X inches.” Where the requirement states a specified range, such as in Section 609.4 where grab bars must be installed between 33 inches and 36 inches above the floor, the range provides an adequate tolerance and therefore no tolerance outside of the range at either end point is permitted. Where a requirement is a minimum or a maximum dimension that does not have two specific minimum and maximum end points, tolerances may apply. Where an element is to be installed at the minimum or maximum permitted dimension, such as “15 inches minimum” or “5 pounds maximum,” it would not be good practice to specify “5 pounds (plus X pounds) or 15 inches (minus X inches).” Rather, it would be good practice to specify a dimension less than the required maximum (or more than the required minimum) by the amount of the expected field or manufacturing tolerance and not to state any tolerance in conjunction with the specified dimension. Specifying dimensions in design in the manner described above will better ensure that facilities and elements accomplish the level of accessibility intended by these requirements. It will also more often produce an end result of strict and literal compliance with the stated requirements and eliminate enforcement difficulties and issues that might otherwise arise. Information on specific tolerances may be available from industry or trade organizations, code groups and building officials, and published references. 104.2 Calculation of Percentages. Where the required number of elements or facilities to be provided is determined by calculations of ratios or percentages and remainders or fractions result, the next greater whole number of such elements or facilities shall be provided. Where the determination of the required size or dimension of an element or facility involves ratios or percentages, rounding down for values less than one half shall be permitted. 2 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 SCOPING CHAPTER 1: APPLICATION AND ADMINISTRATION FIGURE 104 GRAPHIC CONVENTION FOR FIGURES FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 3 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 1: APPLICATION AND ADMINISTRATION SCOPING 104.3 Figures. Unless specifically stated otherwise, figures are provided for informational purposes only. 105 REFERENCED STANDARDS 105.1 General. The standards listed in 105.2 are incorporated by reference in this code and are part of the requirements to the prescribed extent of each such reference. The Director of the Federal Register has approved these standards for incorporation by reference in accordance with 5 U.S.C. 552(a) and 1 CFR part 51. Copies of the referenced standards may be inspected at the Architectural and Transportation Barriers Compliance Board, 1331 F Street, NW, Suite 1000, Washington, DC 20004; at the Department of Justice, Civil Rights Division, Disability Rights Section, 1425 New York Avenue, NW, Washington, DC; at the Department of Transportation, 400 Seventh Street, SW, Room 10424, Washington DC; or at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to http://www.archives.gov/federal_register/ code_of_federal_regulations/ibr_locations.html. 105.2 Referenced Standards. The specific edition of the standards listed below are referenced in this code. Where differences occur between this code and the referenced standards, this code applies. 105.2.1 ANSI/BHMA. Copies of the referenced standards may be obtained from the Builders Hardware Manufacturers Association, 355 Lexington Avenue, 17th floor, New York, NY 10017 (http:// www.buildershardware.com). ANSI/BHMA A156.10-1999 American National Standard for Power Operated Pedestrian Doors (see 404.3). ANSI/BHMA A156.19-1997 American National Standard for Power Assist and Low Energy Power Operated Doors (see 404.3, 408.3.2.1, and 409.3.1). ANSI/BHMA A156.19-2002 American National Standard for Power Assist and Low Energy Power Operated Doors (see 404.3, 408.3.2.1, and 409.3.1). Advisory 105.2.1 ANSI/BHMA. ANSI/BHMA A156.10-1999 applies to power operated doors for pedestrian use which open automatically when approached by pedestrians. Included are provisions intended to reduce the chance of user injury or entrapment. ANSI/BHMA A156.19-1997 and A156.19-2002 applies to power assist doors, low energy power operated doors or low energy power open doors for pedestrian use not provided for in ANSI/BHMA A156.10 for Power Operated Pedestrian Doors. Included are provisions intended to reduce the chance of user injury or entrapment. 105.2.2 ASME. Copies of the referenced standards may be obtained from the American Society of Mechanical Engineers, Three Park Avenue, New York, New York 10016 (http://www.asme.org). ASME A17.1-2000 Safety Code for Elevators and Escalators, including ASME A17.1a-2002 Addenda and ASME A17.1b-2003 Addenda (see 407.1, 408.1, 409.1, and 810.9). ASME A18.1-1999 Safety Standard for Platform Lifts and Stairway Chairlifts, including ASME A18.1a-2001 Addenda and ASME A18.1b-2001 Addenda (see 410.1). ASME A18.1-2003 Safety Standard for Platform Lifts and Stairway Chairlifts, (see 410.1). 4 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 SCOPING CHAPTER 1: APPLICATION AND ADMINISTRATION Advisory 105.2.2 ASME. ASME A17.1-2000 is used by local jurisdictions throughout the United States for the design, construction, installation, operation, inspection, testing, maintenance, alteration, and repair of elevators and escalators. The majority of the requirements apply to the operational machinery not seen or used by elevator passengers. ASME A17.1 requires a two-way means of emergency communications in passenger elevators. This means of communication must connect with emergency or authorized personnel and not an automated answering system. The communication system must be push button activated. The activation button must be permanently identified with the word “HELP.” A visual indication acknowledging the establishment of a communications link to authorized personnel must be provided. The visual indication must remain on until the call is terminated by authorized personnel. The building location, the elevator car number, and the need for assistance must be provided to authorized personnel answering the emergency call. The use of a handset by the communications system is prohibited. Only the authorized personnel answering the call can terminate the call. Operating instructions for the communications system must be provided in the elevator car. The provisions for escalators require that at least two flat steps be provided at the entrance and exit of every escalator and that steps on escalators be demarcated by yellow lines 2 inches wide maximum along the back and sides of steps. ASME A18.1-1999 and ASME A18.1-2003 address the design, construction, installation, operation, inspection, testing, maintenance and repair of lifts that are intended for transportation of persons with disabilities. Lifts are classified as: vertical platform lifts, inclined platform lifts, inclined stairway chairlifts, private residence vertical platform lifts, private residence inclined platform lifts, and private residence inclined stairway chairlifts. This code does not permit the use of inclined stairway chairlifts which do not provide platforms because such lifts require the user to transfer to a seat. ASME A18.1 contains requirements for runways, which are the spaces in which platforms or seats move. The standard includes additional provisions for runway enclosures, electrical equipment and wiring, structural support, headroom clearance (which is 80 inches minimum), lower level access ramps and pits. The enclosure walls not used for entry or exit are required to have a grab bar the full length of the wall on platform lifts. Access ramps are required to meet requirements similar to those for ramps in Chapter 4 of this code. Each of the lift types addressed in ASME A18.1 must meet requirements for capacity, load, speed, travel, operating devices, and control equipment. The maximum permitted height for operable parts is consistent with Section 308 of this code. The standard also addresses attendant operation. However, Section 410.1 of this code does not permit attendant operation. 105.2.3 ASTM. Copies of the referenced standards may be obtained from the American Society for Testing and Materials, 100 Bar Harbor Drive, West Conshohocken, Pennsylvania 19428 (http://www.astm.org). ASTM F 1292-99 Standard Specification for Impact Attenuation of Surface Systems Under and Playground Equipment (see 1008.2.6.2). Around ASTM F 1292-04 Standard Specification for Impact Attenuation of Surfacing Materials Within the Use Zone of Playground Equipment (see 1008.2.6.2). ASTM F 1487-01 Standard Consumer Safety Performance Specification for Playground Equipment for Public Use (see 106.5). ASTM F 1951-99 Standard Specification for Determination of Accessibility of Surface Systems Under and Around Playground Equipment (see 1008.2.6.1). FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 5 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 1: APPLICATION AND ADMINISTRATION SCOPING Advisory 105.2.3 ASTM. ASTM F 1292-99 and ASTM F 1292-04 establish a uniform means to measure and compare characteristics of surfacing materials to determine whether materials provide a safe surface under and around playground equipment. These standards are referenced in the play areas requirements of this code when an accessible surface is required inside a play area use zone where a fall attenuating surface is also required. The standards cover the minimum impact attenuation requirements, when tested in accordance with Test Method F 355, for surface systems to be used under and around any piece of playground equipment from which a person may fall. ASTM F 1487-01 establishes a nationally recognized safety standard for public playground equipment to address injuries identified by the U.S. Consumer Product Safety Commission. It defines the use zone, which is the ground area beneath and immediately adjacent to a play structure or play equipment designed for unrestricted circulation around the equipment and on whose surface it is predicted that a user would land when falling from or exiting a play structure or equipment. The play areas requirements in this code reference the ASTM F 1487 standard when defining accessible routes that overlap use zones requiring fall attenuating surfaces. If the use zone of a playground is not entirely surfaced with an accessible material, at least one accessible route within the use zone must be provided from the perimeter to all accessible play structures or components within the playground. ASTM F 1951-99 establishes a uniform means to measure the characteristics of surface systems in order to provide performance specifications to select materials for use as an accessible surface under and around playground equipment. Surface materials that comply with this standard and are located in the use zone must also comply with ASTM F 1292. The test methods in this standard address access for children and adults who may traverse the surfacing to aid children who are playing. When a surface is tested it must have an average work per foot value for straight propulsion and for turning less than the average work per foot values for straight propulsion and for turning, respectively, on a hard, smooth surface with a grade of 7% (1:14). 105.2.4 ICC/IBC. Copies of the referenced standard may be obtained from the International Code Council, 5203 Leesburg Pike, Suite 600, Falls Church, Virginia 22041 (www.iccsafe.org). International Building Code, 2000 Edition (see 207.1, 207.2, 216.4.2, 216.4.3, and 1005.2.1). International Building Code, 2001 Supplement (see 207.1 and 207.2). International Building Code, 2003 Edition (see 207.1, 207.2, 216.4.2, 216.4.3, and 1005.2.1). Advisory 105.2.4 ICC/IBC. International Building Code (IBC)-2000 (including 2001 Supplement to the International Codes) and IBC-2003 are referenced for means of egress, areas of refuge, and railings provided on fishing piers and platforms. At least one accessible means of egress is required for every accessible space and at least two accessible means of egress are required where more than one means of egress is required. The technical criteria for accessible means of egress allow the use of exit stairways and evacuation elevators when provided in conjunction with horizontal exits or areas of refuge. While typical elevators are not designed to be used during an emergency evacuation, evacuation elevators are designed with standby power and other features according to the elevator safety standard and can be used for the evacuation of individuals with disabilities. The IBC also provides requirements for areas of refuge, which are fire-rated spaces on levels above or below the exit discharge levels where people unable to use stairs can go to register a call for assistance and wait for evacuation. The recreation facilities requirements of this code references two sections in the IBC for fishing piers and platforms. An exception addresses the height of the railings, guards, or handrails where a fishing pier or platform is required to include a guard, railing, or handrail higher than 34 inches (865 mm) above the ground or deck surface. 105.2.5 NFPA. Copies of the referenced standards may be obtained from the National Fire Protection Association, 1 Batterymarch Park, Quincy, Massachusetts 02169-7471, (http://www.nfpa.org). 6 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 SCOPING CHAPTER 1: APPLICATION AND ADMINISTRATION NFPA 72 National Fire Alarm Code, 1999 Edition (see 702.1 and 809.5.2). NFPA 72 National Fire Alarm Code, 2002 Edition (see 702.1 and 809.5.2). Advisory 105.2.5 NFPA. NFPA 72-1999 and NFPA 72-2002 address the application, installation, performance, and maintenance of protective signaling systems and their components. The NFPA 72 incorporates Underwriters Laboratory (UL) 1971 by reference. The standard specifies the characteristics of audible alarms, such as placement and sound levels. However, Section 702 of these requirements limits the volume of an audible alarm to 110 dBA, rather than the maximum 120 dBA permitted by NFPA 72-1999. NFPA 72 specifies characteristics for visible alarms, such as flash frequency, color, intensity, placement, and synchronization. However, Section 702 of this code requires that visual alarm appliances be permanently installed. UL 1971 specifies intensity dispersion requirements for visible alarms. In particular, NFPA 72 requires visible alarms to have a light source that is clear or white and has polar dispersion complying with UL 1971. 106 DEFINITIONS 106.1 General. For the purpose of this code, the terms defined in 106.5 have the indicated meaning. Advisory 106.1 General. Terms defined in Section 106.5 are italicized in the text of this code. 106.2 Terms Defined in Referenced Standards. Terms not defined in 106.5 or in regulations issued by the Department of Justice and the Department of Transportation to implement the Americans with Disabilities Act, but specifically defined in a referenced standard, shall have the specified meaning from the referenced standard unless otherwise stated. 106.3 Undefined Terms. The meaning of terms not specifically defined in 106.5 or in regulations issued by the Department of Justice and the Department of Transportation to implement the Americans with Disabilities Act or in referenced standards shall be as defined by collegiate dictionaries in the sense that the context implies. 106.4 Interchangeability. Words, terms and phrases used in the singular include the plural and those used in the plural include the singular. 106.5 Defined Terms. Accessible. A site, building, facility, or portion thereof that complies with this part. Accessible Means of Egress. A continuous and unobstructed way of egress travel from any point in a building or facility that provides an accessible route to an area of refuge, a horizontal exit, or a public way. Addition. An expansion, extension, or increase in the gross floor area or height of a building or facility. Administrative Authority. A governmental agency that adopts or enforces regulations and guidelines for the design, construction, or alteration of buildings and facilities. Alteration. A change to a building or facility that affects or could affect the usability of the building or facility or portion thereof. Alterations include, but are not limited to, remodeling, renovation, rehabilitation, reconstruction, historic restoration, resurfacing of circulation paths or vehicular ways, changes or rearrangement of the structural parts or elements, and changes or rearrangement in the plan configuration of walls and full-height partitions. Normal maintenance, reroofing, painting or wallpapering, asbestos removal, or changes to mechanical and electrical systems are not alterations unless they affect the usability of the building or facility. Alterations to an Area Containing a Primary Function (See also, “Primary Function”). Amusement Attraction. Any facility, or portion of a facility, located within an amusement park or theme park which provides amusement without the use of an amusement device. Amusement attractions include, but are not limited to, fun houses, barrels, and other attractions without seats. Amusement Ride. A system that moves persons through a fixed course within a defined area for the purpose of amusement. Amusement Ride Seat. A seat that is built-in or mechanically fastened to an amusement ride intended to be occupied by one or more passengers. Area of Sport Activity. That portion of a room or space where the play or practice of a sport occurs. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 7 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 1: APPLICATION AND ADMINISTRATION SCOPING Assembly Area. A building or facility, or portion thereof, used for the purpose of entertainment, educational or civic gatherings, or similar purposes. For the purposes of these requirements, assembly areas include, but are not limited to, classrooms, lecture halls, courtrooms, public meeting rooms, public hearing rooms, legislative chambers, motion picture houses, auditoria, theaters, playhouses, dinner theaters, concert halls, centers for the performing arts, amphitheaters, arenas, stadiums, grandstands, or convention centers. Assistive Listening System (ALS). An amplification system utilizing transmitters, receivers, and coupling devices to bypass the acoustical space between a sound source and a listener by means of induction loop, radio frequency, infrared, or direct-wired equipment. Boarding Pier. A portion of a pier where a boat is temporarily secured for the purpose of embarking or disembarking. Boat Launch Ramp. A sloped surface designed for launching and retrieving trailered boats and other water craft to and from a body of water. Boat Slip. That portion of a pier, main pier, finger pier, or float where a boat is moored for the purpose of berthing, embarking, or disembarking. Building. Any structure used or intended for supporting or sheltering any use or occupancy. Catch Pool. A pool or designated section of a pool used as a terminus for water slide flumes. Characters. Letters, numbers, punctuation marks and typographic symbols. Children’s Use. Describes spaces and elements specifically designed for use primarily by people 12 years old and younger. Circulation Path. An exterior or interior way of passage provided for pedestrian travel, including but not limited to, walks, hallways, courtyards, elevators, platform lifts, ramps, stairways, and landings. Closed-Circuit Telephone. A telephone with a dedicated line such as a house phone, courtesy phone or phone that must be used to gain entry to a facility. Commerce. Travel, trade, traffic, commerce, transportation, or communication: (1) Among the several states; (2) Between any foreign country or any territory or possession and any state; or (3) Between points in the same state but through another state or foreign country. Commercial Facilities. Facilities: (1) Whose operations will affect commerce; (2) That are intended for nonresidential use by a private entity; and (3) That are not: (a) Facilities that are covered or expressly exempted from coverage under the Fair Housing Act of 1968, as amended (42 U.S.C. 3601-3631); (b) Aircraft; or (c) Railroad locomotives, railroad freight cars, railroad cabooses, commuter or intercity passenger rail cars (including coaches, dining cars, sleeping cars, lounge cars, and food service cars), and any other railroad cars described in Section 242 of the ADA or covered under Title II of the ADA, or railroad rights-of-way. For purposes of this definition, “rail” and “railroad” have the meaning given the term “railroad” in Section 202(e) of the Federal Railroad Safety Act of 1970 [45 U.S.C. 431(e)]. Common Use. Interior or exterior circulation paths, rooms, spaces, or elements that are not for public use and are made available for the shared use of two or more people. Cross Slope. The slope that is perpendicular to the direction of travel (see running slope). Curb Ramp. A short ramp cutting through a curb or built up to it. 8 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 SCOPING CHAPTER 1: APPLICATION AND ADMINISTRATION Designated Public Transportation. Transportation provided by a public entity (other than public school transportation) by bus, rail, or other conveyance (other than transportation by aircraft or inter-city or commuter rail transportation) that provides the general public with general or special service, including charter service, on a regular and continuing basis. Detectable Warning. A standardized surface feature built in or applied to walking surfaces or other elements to warn of hazards on a circulation path. Disability. With respect to an individual, a physical or mental impairment that substantially limits one or more of the major life activities of such individual; a record of such an impairment; or being regarded as having such an impairment. (1) The phrase physical or mental impairment means: (a) Any physiological disorder or condition, cosmetic disfigurement, or an anatomical loss affecting one or more of the following body systems; neurological; musculoskeletal; special sense organs; respiratory, including speech organs; cardiovascular; reproductive; digestive; genitourinary; hemic and lymphatic; skin; and endocrine; (b) Any mental or psychological disorder such as mental retardation, organic brain syndrome, emotional or mental illness, and specific learning disabilities; (c) The phrase physical or mental impairment includes, but is not limited to, such contagious and noncontagious diseases and conditions as orthopedic, visual, speech, and hearing impairments, cerebral palsy, epilepsy, muscular dystrophy, multiple sclerosis, cancer, heart disease, diabetes, mental retardation, emotional illness, specific learning disabilities, HIV disease (whether symptomatic or asymptomatic), tuberculosis, drug addiction, and alcoholism; (d) The phrase physical or mental impairment does not include homosexuality or bisexuality. (2) The phrase major life activities means functions such as caring for one’s self, performing manual tasks, walking, seeing, hearing, speaking, breathing, learning and working. (3) The phrase has a record of such an impairment means has a history of, or has been misclassified as having, a mental or physical impairment that substantially limits one or more major life activities. (4) The phrase is regarded as having an impairment means: (a) Has a physical or mental impairment that does not substantially limit major life activities but that is treated by a private entity as constituting such a limitation; (b) Has a physical or mental impairment that substantially limits major life activities only as a result of the attitudes of others toward such impairment; or (c) Has none of the impairments defined in paragraph (1) of this definition but is treated by a private entity as having such an impairment. (5) The term “disability” does not include: (a) Transvestism, transsexualism, pedophilia, exhibitionism, voyeurism, gender identity disorders not resulting from physical impairments, or other sexual behavior disorders; (b) Compulsive gambling, kleptomania or pyromania; or (c) Psychoactive substance use disorders resulting from current illegal use of drugs. Element. An architectural or mechanical component of a building, facility, space, or site. Elevated Play Component. A play component that is approached above or below grade and that is part of a composite play structure consisting of two or more play components attached or functionally linked to create an integrated unit providing more than one play activity. Employee Work Area. All or any portion of a space used only by employees and used only for work. Corridors, toilet rooms, kitchenettes and break rooms are not employee work areas. Entrance. Any access point to a building or portion of a building or facility used for the purpose of entering. An entrance includes the approach walk, the vertical access leading to the entrance platform, the entrance platform itself, vestibule if provided, the entry door or gate, and the hardware of the entry door or gate. Existing Facility. A facility in existence on any given date, without regard to whether the facility may also be considered newly constructed or altered under this code. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 9 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 1: APPLICATION AND ADMINISTRATION SCOPING Facility. All or any portion of buildings, structures, site improvements, elements, and pedestrian routes or vehicular ways located on a site. Gangway. A variable-sloped pedestrian walkway that links a fixed structure or land with a floating structure. Gangways that connect to vessels are not addressed by this code. Golf Car Passage. A continuous passage on which a motorized golf car can operate. Ground Level Play Component. A play component that is approached and exited at the ground level. Housing at a Place of Education. Housing operated by or on behalf of an elementary, secondary, undergraduate, or postgraduate school, or other place of education, including dormitories, suites, apartments, or other places of residence. Key Station. Rapid and light rail stations, and commuter rail stations, as defined under criteria established by the Department of Transportation in 49 CFR 37.47 and 49 CFR 37.51, respectively. Mail Boxes. Receptacles for the receipt of documents, packages, or other deliverable matter. Mail boxes include, but are not limited to, post office boxes and receptacles provided by commercial mail-receiving agencies, apartment facilities, or schools. Marked Crossing. A crosswalk or other identified path intended for pedestrian use in crossing a vehicular way. Maximum Extent Feasible. The phrase “to the maximum extent feasible,” as used in this code, applies to the case where the nature of an existing facility makes it virtually impossible to comply fully with applicable accessibility standards through a planned alteration. In these circumstances, the alteration shall provide the maximum physical accessibility feasible. Any altered features of the facility that can be made accessible shall be made accessible. If providing accessibility in conformance with this section to individuals with certain disabilities (e.g., those who use wheelchairs) would not be feasible, the facility shall be made accessible to persons with other types of disabilities (e.g., those who use crutches, those who have impaired vision or hearing, or those who have other impairments). Mezzanine. An intermediate level or levels between the floor and ceiling of any story with an aggregate floor area of not more than one-third of the area of the room or space in which the level or levels are located. Mezzanines have sufficient elevation that space for human occupancy can be provided on the floor below. Occupant Load. The number of persons for which the means of egress of a building or portion of a building is designed. Operable Part. A component of an element used to insert or withdraw objects, or to activate, deactivate, or adjust the element. Path of Travel. (1) A path of travel includes a continuous, unobstructed way of pedestrian passage by means of which the altered area may be approached, entered, and exited, and which connects the altered area with an exterior approach (including sidewalks, streets, and parking areas), an entrance to the facility, and other parts of the facility. (2) An accessible path of travel may consist of walks and sidewalks, curb ramps and other interior or exterior pedestrian ramps; clear floor paths through lobbies, corridors, rooms, and other improved areas; parking access aisles; elevators and lifts; or a combination of these elements. In transportation facilities covered by 49 CFR 37, an accessible path of travel may include walks and sidewalks, curb ramps and other interior or exterior pedestrian ramps, clear floor paths through corridors, waiting areas, concourses, and other improved areas, parking access aisles, elevators and lifts, bridges, tunnels, or other passageways between platforms, or a combination of these and other elements. (3) For the purposes of this code, the term “path of travel” also includes the restrooms, telephones, and drinking fountains serving the altered area. Pictogram. A pictorial symbol that represents activities, facilities, or concepts. 10 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 SCOPING CHAPTER 1: APPLICATION AND ADMINISTRATION Places of Lodging. See “Place of Public Accommodation.” Place of Public Accommodation. A facility, operated by a private entity, whose operations affect commerce and fall within at least one of the following categories: (1) Places of lodging. Except for an establishment located within a facility that contains not more than five rooms for rent or hire and that actually is occupied by the proprietor of the establishment as the residence of the proprietor. For purposes of this part, a facility is a “place of lodging” if it is— (i) An inn, hotel, or motel; or (ii) A facility that— (A) Provides guest rooms for sleeping for stays that primarily are short-term in nature (generally 30 days or less) where the occupant does not have the right to return to a specific room or unit after the conclusion of his or her stay; and (B) Provides guest rooms under conditions and with amenities similar to a hotel, motel, or inn, including the following— (1) On- or off-site management and reservations service; (2) Rooms available on a walk-up or call-in basis; (3) Availability of housekeeping or linen service; and (4) Acceptance of reservations for a guest room type without guaranteeing a particular unit or room until check-in, and without a prior lease or security deposit. Resort condominiums are considered to be public lodging establishments pursuant to Section 509.242, F.S.; (2) Establishments serving food and drink. A restaurant, bar, or other establishment serving food or drink; (3) Places of exhibition or entertainment. A motion picture house, theater, concert hall, stadium, or other place of exhibition or entertainment; (4) Places of public gathering. An auditorium, convention center, lecture hall, or other place of public gathering; (5) Sales or rental establishments. A bakery, grocery store, clothing store, hardware store, shopping center, or other sales or rental establishment; (6) Service establishments. A laundromat, dry-cleaner, bank, barber shop, beauty shop, travel service, shoe repair service, funeral parlor, gas station, office of an accountant or lawyer, pharmacy, insurance office, professional office of a health care provider, hospital, or other service establishment; (7) Stations used for specified public transportation. A terminal, depot, or other station used for specified public transportation; (8) Places of public display or collection. A museum, library, gallery, or other place of public display or collection; (9) Places of recreation. A park, zoo, amusement park, or other place of recreation; (10) Places of education. A nursery, elementary, secondary, undergraduate, or postgraduate private school, or other place of education; (11) Social service center establishments. A day care center, senior citizen center, homeless shelter, food bank, adoption agency, or other social service center establishment; (12) Places of exercise or recreation. A gymnasium, health spa, bowling alley, golf course, or other place of exercise or recreation; Primary Function. A major activity for which the facility is intended. Areas that contain a primary function include, but are not limited to, the customer services lobby of a bank, the dining area of a cafeteria, the meeting rooms in a conference center, as well as offices and other work areas in which the activities of the public entity, public accommodation or other private entity using the facility are carried out. Mechanical rooms, boiler rooms, supply storage rooms, employee lounges or locker rooms, janitorial closets, entrances, and corridors are not areas containing a primary function. Restrooms are not areas containing a primary function unless the provision of restrooms is a primary purpose of the area, e.g., in highway rest stops. Areas of transportation facilities that involve primary functions include, but are not necessarily limited to, ticket purchase and collection areas, passenger waiting FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 11 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 1: APPLICATION AND ADMINISTRATION SCOPING areas, train or bus platforms, baggage checking and return areas and employment areas (except those involving non-occupiable spaces accessed only by ladders, catwalks, crawl spaces, very narrow passageways, or freight (non-passenger) elevators which are frequented only by repair personnel). Play Area. A portion of a site containing play components designed and constructed for children. Play Component. An element intended to generate specific opportunities for play, socialization, or learning. Play components are manufactured or natural; and are stand-alone or part of a composite play structure. Private Building or Facility. A place of public accommodation or a commercial building or facility subject to title III of the ADA and 28 CFR part 36 or a transportation building or facility subject to title III of the ADA and 49 CFR 37.45. Private Club. A private club or establishment exempted from coverage under title II of the Civil Rights Act of 1964 (42 U.S.C. 2000a(e)). Private Entity. A person or entity other than a public entity. Professional Office of a Health Care Provider. A location where a person or entity, regulated by a State to provide professional services related to the physical or mental health of an individual, makes such services available to the public. The facility housing the “professional office of a health care provider” only includes floor levels housing at least one health care provider, or any floor level designed or intended for use by at least one health care provider. Public accommodation. A private entity that owns, leases (or leases to), or operates a place of public accommodation. Public Building or Facility. A building or facility or portion of a building or facility designed, constructed, or altered by, on behalf of, or for the use of a public entity subject to title II of the ADA and 28 CFR part 35 or to title II of the ADA and 49 CFR 37.41 or 37.43. Public entity. (1) Any State or local government; (2) Any department, agency, special purpose district, or other instrumentality of a State or States or local government; and (3) The National Railroad Passenger Corporation, and any commuter authority (as defined in section 103(8) of the Rail Passenger Service Act). (45 U.S.C. 541) Public Entrance. An entrance that is not a service entrance or a restricted entrance. Public Use. Interior or exterior rooms, spaces, or elements that are made available to the public. Public use may be provided at a building or facility that is privately or publicly owned. Public Way. Any street, alley or other parcel of land open to the outside air leading to a public street, which has been deeded, dedicated or otherwise permanently appropriated to the public for public use and which has a clear width and height of not less than 10 feet (3050 mm). Qualified Historic Building or Facility. A building or facility that is listed in or eligible for listing in the National Register of Historic Places, or designated as historic under an appropriate State or local law. Ramp. A walking surface that has a running slope steeper than 1:20. Readily Achievable. Easily accomplishable and able to be carried out without much difficulty or expense. Residential Dwelling Unit. A unit intended to be used as a residence, that is primarily long-term in nature. Residential dwelling units do not include transient lodging, inpatient medical care, licensed long-term care, and detention or correctional facilities. Resort Condominium. (Section 509.242, F.S.). A resort condominium is any unit or group of units in a condominium, cooperative, or time-share plan which is rented more than three times a calendar year for periods of less than 30 days or one calendar month, whichever is less, or which is advertised or held out to the public as a place regularly rented for periods of less than 30 days or one calendar month, whichever is less (see also, Places of Lodging). Restricted Entrance. An entrance that is made available for common use on a controlled basis but not public use and that is not a service entrance. Running Slope. The slope that is parallel to the direction of travel (see cross slope). 12 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 SCOPING CHAPTER 1: APPLICATION AND ADMINISTRATION Self-Service Storage. Building or facility designed and used for the purpose of renting or leasing individual storage spaces to customers for the purpose of storing and removing personal property on a self-service basis. Service Entrance. An entrance intended primarily for delivery of goods or services. Shopping Center or Shopping Mall. (1) A building housing five or more sales or rental establishments; or (2) A series of buildings on a common site, either under common ownership or common control or developed either as one project or as a series of related projects, housing five or more sales or rental establishments. For purposes of this section, places of public accommodation of the types listed in Paragraph (5) of the definition of “Place of public accommodation” in this code are considered sales or rental establishments. The facility housing a “shopping center or shopping mall” only includes floor levels housing at least one sales or rental establishment, or any floor level designed or intended for use by at least one sales or rental establishment. Site. A parcel of land bounded by a property line or a designated portion of a public right-of-way. Soft Contained Play Structure. A play structure made up of one or more play components where the user enters a fully enclosed play environment that utilizes pliable materials, such as plastic, netting, or fabric. Space. A definable area, such as a room, toilet room, hall, assembly area, entrance, storage room, alcove, courtyard, or lobby. Specified public transportation. Transportation by bus, rail, or any other conveyance (other than aircraft) provided by a private entity to the general public, with general or special service (including charter service) on a regular and continuing basis. Story. That portion of a building or facility designed for human occupancy included between the upper surface of a floor and upper surface of the floor or roof next above. A story containing one or more mezzanines has more than one floor level. Structural Frame. The columns and the girders, beams, and trusses having direct connections to the columns and all other members that are essential to the stability of the building or facility as a whole. Tactile. An object that can be perceived using the sense of touch. Technically Infeasible. With respect to an alteration of a building or a facility, something that has little likelihood of being accomplished because existing structural conditions would require removing or altering a load-bearing member that is an essential part of the structural frame; or because other existing physical or site constraints prohibit modification or addition of elements, spaces, or features that are in full and strict compliance with the minimum requirements. Teeing Ground. In golf, the starting place for the hole to be played. Theme Park Or Entertainment Complex. (Section 509.0013(9), F.S.). Theme park or entertainment complex means a complex comprised of at least 25 contiguous acres owned and controlled by the same business entity and which contains permanent exhibitions and a variety of recreational activities and has a minimum of 1 million visitors annually. Transfer Device. Equipment designed to facilitate the transfer of a person from a wheelchair or other mobility aid to and from an amusement ride seat. Transient Lodging. A building or facility containing one or more guest room(s) for sleeping that provides accommodations that are primarily short-term in nature. Transient lodging does not include residential dwelling units intended to be used as a residence, inpatient medical care facilities, licensed long-term care facilities, detention or correctional facilities, or private buildings or facilities that contain not more than five rooms for rent or hire and that are actually occupied by the proprietor as the residence of such proprietor. Transition Plate. A sloping pedestrian walking surface located at the end(s) of a gangway. TTY. An abbreviation for teletypewriter. Machinery that employs interactive text-based communication through the transmission of coded signals across the telephone network. TTYs may include, for example, devices known as TDDs (telecommunication display devices or telecommunication devices for deaf persons) or computers with special modems. TTYs are also called text telephones. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 13 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 1: APPLICATION AND ADMINISTRATION SCOPING Use Zone. The ground level area beneath and immediately adjacent to a play structure or play equipment that is designated by ASTM F 1487 (incorporated by reference, see “Referenced Standards” in Chapter 1) for unrestricted circulation around the play equipment and where it is predicted that a user would land when falling from or exiting the play equipment. Vehicular Way. A route provided for vehicular traffic, such as in a street, driveway, or parking facility. Walk. An exterior prepared surface for pedestrian use, including pedestrian areas such as plazas and courts. Wheelchair. A manually-operated or power-driven device designed primarily for use by an individual with a mobility disability for the main purpose of indoor or of both indoor and outdoor locomotion. This definition does not apply to Federal wilderness areas; wheelchairs in such areas are defined in section 508(c)(2) of the ADA, 42 U.S.C. 12207(c)(2). Wheelchair Space. Space for a single wheelchair and its occupant. Work Area Equipment. Any machine, instrument, engine, motor, pump, conveyor, or other apparatus used to perform work. As used in this code, this term shall apply only to equipment that is permanently installed or built-in in employee work areas. Work area equipment does not include passenger elevators and other accessible means of vertical transportation. 14 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 2: SCOPING REQUIREMENTS 201 APPLICATION 201.1 Scope. This code establishes standards for accessibility to places of public accommodation and commercial facilities by individuals with disabilities. This code shall also apply: to state and local government facilities pursuant to Section 553.503, F.S.; to private clubs pursuant to Section 553.505, F.S.; and to residential buildings pursuant to Section 553.504(2), F.S., and the ADA Standards for Accessible Design. All new or altered public buildings and facilities, private buildings and facilities, places of public accommodation and commercial facilities subject to this code shall comply with this code. This code applies to: All areas of newly designed and newly constructed buildings and facilities as determined by the ADA Standards for Accessible Design; portions of altered buildings and facilities as determined by the ADA Standards for Accessible Design; a building or facility that is being converted from residential to nonresidential or mixed use as defined by the Florida Building Code where such building or facility must, at a minimum, comply with s. 553.508, F.S., and the requirements for alterations as determined by the ADA Standards for Accessible Design; buildings and facilities where the original construction or any former alteration or renovation was carried out in violation of applicable permitting law. 201.1.1 Vertical accessibility. Sections 553.501-553.513, F.S., and the ADA Standards for Accessible Design do not relieve the owner of any building, structure or facility governed by those sections from the duty to provide vertical accessibility to all levels above and below the occupiable grade level regardless of whether the Standards require an elevator to be installed in such building, structure or facility, except for: (1) Elevator pits, elevator penthouses, mechanical rooms, piping or equipment catwalks and automobile lubrication and maintenance pits and platforms. (2) Unoccupiable spaces, such as rooms, enclosed spaces and storage spaces that are not designed for human occupancy, for public accommodations or for work areas. (3) Occupiable spaces and rooms that are not open to the public and that house no more than five persons, including, but not limited to equipment control rooms and projection booths. (4) Theaters, concert halls, and stadiums, or other large assembly areas that have stadium-style seating or tiered seating if sections 221 and 802 are met. (5) All play and recreation areas if the requirements of chapter 10 are met. (6) All employee areas as exempted by 203.9. (7) Facilities, sites and spaces exempted by section 203. Buildings, structures and facilities must, at a minimum, comply with the requirements of the ADA Standards for Accessible Design. Advisory 201.1 Scope. These requirements are to be applied to all areas of a facility unless exempted, or where scoping limits the number of multiple elements required to be accessible. For example, not all medical care patient rooms are required to be accessible; those that are not required to be accessible are not required to comply with these requirements. However, common use and public use spaces such as recovery rooms, examination rooms, and cafeterias are not exempt from these requirements and must be accessible. Florida vertical accessibility requires all levels in all new buildings, structures and facilities and all altered areas of existing buildings, structures and facilities to be accessible to persons with disabilities. All new and altered areas must comply with the ADA Standards for Accessible Design including requirements for accessible routes. Where the ADA Standards do not require an accessible route to each and every level, the Florida requirement may be waived down to the requirement of the ADA Standards. 201.2 Application Based on Building or Facility Use. Where a site, building, facility, room, or space contains more than one use, each portion shall comply with the applicable requirements for that use. 201.2.1 Commercial facilities and places of public accommodation located in private residences. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 15 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 2: SCOPING REQUIREMENTS SCOPING 201.2.1.1 When a commercial facility or place of public accommodation is located in a private residence, the portion of the residence used exclusively as a residence is not covered by this subpart, but that portion used exclusively in the operation of the commercial facility or that portion used both for the commercial facility and for residential purposes is covered by the new construction and alterations requirements of this subpart. 201.2.2.2 The portion of the residence covered under paragraph (b)(1) of this section extends to those elements used to enter the commercial facility, including the homeowner’s front sidewalk, if any, the door or entryway, and hallways; and those portions of the residence, interior or exterior, available to or used by employees or visitors or customers and clients of the commercial facility, including restrooms. 201.3 Temporary and Permanent Structures. These requirements shall apply to temporary and permanent buildings and facilities. Advisory 201.3 Temporary and Permanent Structures. Temporary buildings or facilities covered by these requirements include, but are not limited to, reviewing stands, temporary classrooms, bleacher areas, stages, platforms and daises, fixed furniture systems, wall systems, and exhibit areas, temporary banking facilities, and temporary health screening facilities. Structures and equipment directly associated with the actual processes of construction are not required to be accessible as permitted in 203.2. 201.4 Scope of Coverage. This code applies to fixed or built-in elements of buildings, structures, site improvements and pedestrian routes or vehicular ways located on a site. Unless specifically stated otherwise, advisory notes, appendix notes and figures contained in the code explain or illustrate the requirements; they do not establish enforceable requirements. 202 EXISTING BUILDINGS AND FACILITIES 202.1 General. Additions and alterations to existing buildings or facilities shall comply with 202. 202.2 Additions. Each addition to an existing building or facility shall comply with the requirements for new construction. Each addition that affects or could affect the usability of or access to an area containing a primary function shall comply with 202.4. 202.3 Alterations. Where existing elements or spaces or common areas are altered, each altered element, space or area shall comply with the applicable requirements of Chapter 2 and Section 201.1.1. See Section 208.1 for existing parking. EXCEPTIONS: 1. Unless required by 202.4, where elements or spaces are altered and the circulation path to the altered element or space is not altered, an accessible route shall not be required. 2. In alterations, where compliance with applicable requirements is technically infeasible, the alteration shall comply with the requirements to the maximum extent feasible. 3. Residential dwelling units not required to be accessible in compliance with a standard issued pursuant to the Americans with Disabilities Act or Section 504 of the Rehabilitation Act of 1973, as amended, shall not be required to comply with 202.3. Advisory 202.3 Alterations. Although covered entities are permitted to limit the scope of an alteration to individual elements, the alteration of multiple elements within a room or space may provide a cost-effective opportunity to make the entire room or space accessible. Any elements or spaces of the building or facility that are required to comply with these requirements must be made accessible within the scope of the alteration, to the maximum extent feasible. If providing accessibility in compliance with these requirements for people with one type of disability (e.g., people who use wheelchairs) is not feasible, accessibility must still be provided in compliance with the requirements for people with other types of disabilities (e.g., people who have hearing impairments or who have vision impairments) to the extent that such accessibility is feasible. 16 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 SCOPING CHAPTER 2: SCOPING REQUIREMENTS Florida requirements for existing parking s.553.5041(g), F.S., and vertical accessibility s.553.509, F.S., are incorporated into this general section applicable to alterations. Florida requirements may be waived down to the ADA Standards requirements. 202.3.1 Prohibited Reduction in Access. An alteration that decreases or has the effect of decreasing the accessibility of a building or facility below the requirements for new construction at the time of the alteration is prohibited. Advisory 202.3.1 Prohibited Reduction in Access. Department of Justice regulations 28 CFR 35.133 for public entities (Title II) and 28 CFR 36.211 for private entities (Title III) clarify that reduction of accessibility is benchmarked to the 2010 ADA Standards for Accessible Design as adopted by this code. Those regulations state: “If the 2010 Standards reduce the technical requirements or the number of required accessible elements below the number required by the 1991 Standards, the technical requirements or the number of accessible elements in a facility subject to this part may be reduced in accordance with the requirements of the 2010 Standards.” 202.3.2 Extent of Application. An alteration of an existing element, space, or area of a building or facility shall not impose a requirement for accessibility greater than required for new construction. 202.3.3 Barriers at Common or Emergency Entrances and Exits. Barriers at common or emergency entrances and exits of business establishments conducting business with the general public that are existing, under construction, or under contract for construction which would prevent a person from using such entrances or exits shall be removed. 202.4 Alterations Affecting Primary Function Areas. In addition to the requirements of 202.3, an alteration that affects or could affect the usability of or access to an area containing a primary function shall be made so as to ensure that, to the maximum extent feasible, the path of travel to the altered area, including the rest rooms, telephones, and drinking fountains serving the altered area, are readily accessible to and usable by individuals with disabilities, unless such alterations are disproportionate to the overall alterations in terms of cost pursuant to 202.4.1. Alterations to windows, hardware, controls, electrical outlets, and signage shall not be deemed to be alterations that affect the usability of or access to an area containing a primary function. EXCEPTIONS: 1. Residential dwelling units shall not be required to comply with 202.4. 2. If a private entity has constructed or altered required elements of a path of travel at a place of public accommodation or commercial facility in accordance with the specifications in the 1994 or 1997 Florida Accessibility Code, the private entity is not required to retrofit such elements to reflect incremental changes in the proposed standards solely because of an alteration to a primary function area served by that path of travel. 3. The path of travel requirements shall not apply to measures taken solely to comply with barrier removal requirements. 4. If a public entity has constructed or altered required elements of a path of travel in accordance with the specifications in either the 1994 or 1997 Florida Accessibility Code or the Uniform Federal Accessibility Standards, as an equivalent facilitation, before March 15, 2012, the public entity is not required to retrofit such elements to reflect incremental changes in this code solely because of an alteration to a primary function area served by that path of travel. 5. The path of travel requirement shall not apply to alterations undertaken solely for purposes of meeting the public entity program accessibility requirements of § 35.150, 28 CFR 35. 6. If a tenant is making alterations that would trigger the requirements of this section, those alterations by the tenant in areas that only the tenant occupies do not trigger a path of travel obligation upon the landlord with respect to areas of the facility under the landlord’s authority, if those areas are not otherwise being altered. In existing transportation facilities, an area of primary function shall be as defined under regulations published by the Secretary of the Department of Transportation or the Attorney General (see definition of primary function). Notwithstanding the requirements of this section, section 201.1.1 shall apply. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 17 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 2: SCOPING REQUIREMENTS SCOPING Advisory 202.4 Alterations Affecting Primary Function Areas. An area of a building or facility containing a major activity for which the building or facility is intended is a primary function area. Department of Justice ADA regulations state, “Alterations made to provide an accessible path of travel to the altered area will be deemed disproportionate to the overall alteration when the cost exceeds 20% of the cost of the alteration to the primary function area.” (28 CFR 36.403 (f)(1)). See also Department of Transportation ADA regulations, which use similar concepts in the context of public sector transportation facilities (49 CFR 37.43 (e)(1)). There can be multiple areas containing a primary function in a single building. Primary function areas are not limited to public use areas. For example, both a bank lobby and the bank’s employee areas such as the teller areas and walk-in safe are primary function areas. Also, mixed use facilities may include numerous primary function areas for each use. Areas containing a primary function do not include: mechanical rooms, boiler rooms, supply storage rooms, employee lounges or locker rooms, janitorial closets, entrances, corridors, or restrooms. DOJ regulation 28 CFR 36.403(c) gives the following examples of alterations that effect the usability of or access to an area containing a primary function. Such areas include but are not limited to: remodeling merchandise display areas or employee work areas in a department store; replacing an inaccessible floor surface in the customer service or employee work areas of a bank; redesigning the assembly line area of a factory; or, installing a computer center in an accounting firm. Florida vertical accessibility requirements of s.553.509, F.S., as incorporated in section 201.1.1 of the code, apply to the path of travel upgrades required by 202.4. Florida requirements may be waived down to the ADA Standards requirements. 202.4.1 Disproportionate Cost. Alterations made to provide an accessible path of travel to the altered area will be deemed disproportionate to the overall alteration when the cost exceeds 20% of the cost of the alteration to the primary function area. Costs that may be counted as expenditures required to provide an accessible path of travel may include: (i) costs associated with providing an accessible entrance and an accessible route to the altered area; (ii) costs associated with making restrooms accessible, such as installing grab bars, enlarging toilet stalls, insulating pipes, or installing accessible faucet controls; (iii) costs associated with providing accessible telephones, such as relocating the telephone to an accessible height, installing amplification devices, or installing a text telephone (TTY); (iv) costs associated with relocating an inaccessible drinking fountain. 202.4.2 Accessible Features in the Event of Disproportionality. When the cost of alterations necessary to make the path of travel to the altered area fully accessible is disproportionate to the cost of the overall alteration, the path of travel shall be made accessible to the extent that it can be made accessible without incurring disproportionate costs. In choosing which accessible elements to provide, priority should be given to those elements that will provide the greatest access, in the following order: (i) an accessible entrance; (ii) an accessible route to the altered area; (iii) at least one accessible restroom for each sex or a single unisex restroom; (iv) accessible telephones; (v) accessible drinking fountains; and (vi) when possible, additional accessible elements such as parking, storage, and alarms. 202.4.3 Series of smaller alterations. The obligation to provide an accessible path of travel may not be evaded by performing a series of small alterations to the area served by a single path of travel if those alterations could have been performed as a single undertaking. 202.4.3.1 If an area containing a primary function has been altered without providing an accessible path of travel to that area, and subsequent alterations of that area, or a different area on the same path of travel, are undertaken within three years of the original alteration, the total cost of alterations to the primary function areas on that path of travel during the preceding three year period shall be considered in determining whether the cost of making that path of travel accessible is disproportionate. 202.4.3.2 Only alterations undertaken after January 26, 1992, shall be considered in determining if the cost of providing an accessible path of travel is disproportionate to the overall cost of the alterations. 202.5 Alterations to Qualified Historic Buildings and Facilities. Alterations to a qualified historic building or facility shall comply with 202.3 and 202.4 to the maximum extent feasible. EXCEPTION: Where the State Historic Preservation Officer or Advisory Council on Historic Preservation determines that compliance with the requirements for accessible routes, entrances, or toilet facilities would threaten or destroy the historic significance of the building or facility, the exceptions for alterations to qualified historic buildings or facilities for that element shall be permitted to apply. 18 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 SCOPING CHAPTER 2: SCOPING REQUIREMENTS Advisory 202.5 Alterations to Qualified Historic Buildings and Facilities Exception. State Historic Preservation Officers are State appointed officials who carry out certain responsibilities under the National Historic Preservation Act. State Historic Preservation Officers consult with Federal and State agencies, local governments, and private entities on providing access and protecting significant elements of qualified historic buildings and facilities. There are exceptions for alterations to qualified historic buildings and facilities for accessible routes (206.2.1, Exception 1 and 206.2.3, Exception 7); entrances (206.4, Exception 2); and toilet facilities (213.2, Exception 2). When an entity believes that compliance with the requirements for any of these elements would threaten or destroy the historic significance of the building or facility, the entity should consult with the State Historic Preservation Officer. If the State Historic Preservation Officer agrees that compliance with the requirements for a specific element would threaten or destroy the historic significance of the building or facility, use of the exception is permitted. Public entities have an additional obligation to achieve program accessibility under the Department of Justice ADA regulations. See 28 CFR 35.150. These regulations require public entities that operate historic preservation programs to give priority to methods that provide physical access to individuals with disabilities. If alterations to a qualified historic building or facility to achieve program accessibility would threaten or destroy the historic significance of the building or facility, fundamentally alter the program, or result in undue financial or administrative burdens, the Department of Justice ADA regulations allow alternative methods to be used to achieve program accessibility. In the case of historic preservation programs, such as an historic house museum, alternative methods include using audio-visual materials to depict portions of the house that cannot otherwise be made accessible. In the case of other qualified historic properties, such as an historic government office building, alternative methods include relocating programs and services to accessible locations. The Department of Justice ADA regulations also allow public entities to use alternative methods when altering qualified historic buildings or facilities in the rare situations where the State Historic Preservation Officer determines that it is not feasible to provide physical access using the exceptions permitted in Section 202.5 without threatening or destroying the historic significance of the building or facility. See 28 CFR 35.151(d). The Accessibility Office at the National Endowment for the Arts (NEA) provides a variety of resources for museum operators and historic properties including: the Design for Accessibility Guide and the Disability Symbols. Contact NEA about these and other resources at 202-682-5532 or www.arts.gov. 202.6 Architectural Barrier Removal. Removal of architectural barriers, pursuant to 28 C.F.R. s.36.304, from buildings, structures or facilities shall comply with this code’s requirements for alterations unless compliance would render the removal not readily achievable. In no instance shall the removal of an architectural barrier create a significant risk to the health or safety of an individual with a disability or others. 202.6.1 Measures taken to comply with federal barrier removal requirements shall comply with the applicable requirements for alterations for the element being altered. EXCEPTION: 1. The path of travel requirements of 202.4 shall not apply to measures taken solely to comply with federal architectural barrier removal requirements. 2. If the measures required to remove a barrier would not be readily achievable, a public accommodation may take other readily achievable measures to remove the barrier that do not fully comply with the specified requirements. Such measures include but are not limited to providing a ramp with a steeper slope or widening a doorway to a narrower width than that mandated by the alterations requirements. No measure shall be taken that poses a significant risk to the health or safety of individuals with disabilities or others. 203 GENERAL EXCEPTIONS 203.1 General. Sites, buildings, facilities, and elements are exempt from these requirements to the extent specified by 203. 203.2 Construction Sites. Structures and sites directly associated with the actual processes of construction, including but not limited to, scaffolding, bridging, materials hoists, materials storage, and construction trailers shall not be required to comply with these requirements or to be on an accessible route. Portable toilet units provided for FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 19 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 2: SCOPING REQUIREMENTS SCOPING use exclusively by construction personnel on a construction site shall not be required to comply with 213 or to be on an accessible route. 203.3 Raised Areas. Areas raised primarily for purposes of security, life safety, or fire safety, including but not limited to, observation or lookout galleries, prison guard towers, fire towers, or life guard stands shall not be required to comply with these requirements or to be on an accessible route. 203.4 Limited Access Spaces. Spaces accessed only by ladders, catwalks, crawl spaces, or very narrow passageways shall not be required to comply with these requirements or to be on an accessible route. 203.5 Machinery Spaces. Spaces frequented only by service personnel for maintenance, repair, or occasional monitoring of equipment shall not be required to comply with these requirements or to be on an accessible route. Machinery spaces include, but are not limited to, elevator pits or elevator penthouses; mechanical, electrical or communications equipment rooms; piping or equipment catwalks; water or sewage treatment pump rooms and stations; electric substations and transformer vaults; and highway and tunnel utility facilities. 203.6 Single Occupant Structures. Single occupant structures accessed only by passageways below grade or elevated above standard curb height, including but not limited to, toll booths that are accessed only by underground tunnels, shall not be required to comply with these requirements or to be on an accessible route. 203.7 Detention and Correctional Facilities. In detention and correctional facilities, common use areas that are used only by inmates or detainees and security personnel and that do not serve holding cells or housing cells required to comply with 232, shall not be required to comply with these requirements or to be on an accessible route. 203.8 Residential Facilities. In residential facilities, common use areas that do not serve residential dwelling units required to provide mobility features complying with 809.2 through 809.4 shall not be required to comply with these requirements or to be on an accessible route. 203.9 Employee Work Areas. Spaces and elements within employee work areas shall only be required to comply with 206.2.8, 207.1, and 215.3 and shall be designed and constructed so that individuals with disabilities can approach, enter, and exit the employee work area. Employee work areas, or portions of employee work areas, other than raised courtroom stations, that are less than 300 square feet (28 m2) and elevated 7 inches (180 mm) or more above the finish floor or ground where the elevation is essential to the function of the space shall not be required to comply with these requirements or to be on an accessible route. Advisory 203.9 Employee Work Areas. Although areas used exclusively by employees for work are not required to be fully accessible, consider designing such areas to include non-required turning spaces, and provide accessible elements whenever possible. Under the ADA, employees with disabilities are entitled to reasonable accommodations in the workplace; accommodations can include alterations to spaces within the facility. Designing employee work areas to be more accessible at the outset will avoid more costly retrofits when current employees become temporarily or permanently disabled, or when new employees with disabilities are hired. Contact the Equal Employment Opportunity Commission (EEOC) at www.eeoc.gov for information about title I of the ADA prohibiting discrimination against people with disabilities in the workplace. 203.10 Raised Refereeing, Judging, and Scoring Areas. Raised structures used solely for refereeing, judging, or scoring a sport shall not be required to comply with these requirements or to be on an accessible route. 203.11 Water Slides. Water slides shall not be required to comply with these requirements or to be on an accessible route. 203.12 Animal Containment Areas. Animal containment areas that are not for public use shall not be required to comply with these requirements or to be on an accessible route. Advisory 203.12 Animal Containment Areas. Public circulation routes where animals may travel, such as in petting zoos and passageways alongside animal pens in State fairs, are not eligible for the exception. 203.13 Raised Boxing or Wrestling Rings. Raised boxing or wrestling rings shall not be required to comply with these requirements or to be on an accessible route. 203.14 Raised Diving Boards and Diving Platforms. Raised diving boards and diving platforms shall not be required to comply with these requirements or to be on an accessible route. 203.15 Structural Impracticability. 203.15.1 Full compliance with the requirements of this section is not required where an entity can demonstrate that it is structurally impracticable to meet the requirements. Full compliance will be considered structurally 20 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 SCOPING CHAPTER 2: SCOPING REQUIREMENTS impracticable only in those rare circumstances when the unique characteristics of terrain prevent the incorporation of accessibility features. 203.15.2 If full compliance with this section would be structurally impracticable, compliance with this section is required to the extent that it is not structurally impracticable. In that case, any portion of the facility that can be made accessible shall be made accessible to the extent that it is not structurally impracticable. 203.15.3 If providing accessibility in conformance with this section to individuals with certain disabilities (e.g., those who use wheelchairs) would be structurally impracticable, accessibility shall nonetheless be ensured to persons with other types of disabilities (e.g., those who use crutches or who have sight, hearing, or mental impairments) in accordance with this section. 204 PROTRUDING OBJECTS 204.1 General. Protruding objects on circulation paths shall comply with 307. EXCEPTIONS: 1. Within areas of sport activity, protruding objects on circulation paths shall not be required to comply with 307. 2. Within play areas, protruding objects on circulation paths shall not be required to comply with 307 provided that ground level accessible routes provide vertical clearance in compliance with 1008.2. 205 OPERABLE PARTS 205.1 General. Operable parts on accessible elements, accessible routes, and in accessible rooms and spaces shall comply with 309. EXCEPTIONS: 1. Operable parts that are intended for use only by service or maintenance personnel shall not be required to comply with 309. 2. Electrical or communication receptacles serving a dedicated use shall not be required to comply with 309. 3. Where two or more outlets are provided in a kitchen above a length of counter top that is uninterrupted by a sink or appliance, one outlet shall not be required to comply with 309. 4. Floor electrical receptacles shall not be required to comply with 309. 5. HVAC diffusers shall not be required to comply with 309. 6. Except for light switches, where redundant controls are provided for a single element, one control in each space shall not be required to comply with 309. 7. Cleats and other boat securement devices shall not be required to comply with 309.3. 8. Exercise machines and exercise equipment shall not be required to comply with 309. Advisory 205.1 General. Controls covered by 205.1 include, but are not limited to, light switches, circuit breakers, duplexes and other convenience receptacles, environmental and appliance controls, plumbing fixture controls, and security and intercom systems. 206 ACCESSIBLE ROUTES 206.1 General. Accessible routes shall be provided in accordance with 206 and shall comply with Chapter 4. 206.2 Where Required. Accessible routes shall be provided where required by 206.2. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 21 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 2: SCOPING REQUIREMENTS SCOPING 206.2.1 Site Arrival Points. At least one accessible route shall be provided within the site from accessible parking spaces and accessible passenger loading zones; public streets and sidewalks; and public transportation stops to the accessible building or facility entrance they serve. EXCEPTIONS: 1. Where exceptions for alterations to qualified historic buildings or facilities are permitted by 202.5, no more than one accessible route from a site arrival point to an accessible entrance shall be required. 2. An accessible route shall not be required between site arrival points and the building or facility entrance if the only means of access between them is a vehicular way not providing pedestrian access. Advisory 206.2.1 Site Arrival Points. Each site arrival point must be connected by an accessible route to the accessible building entrance or entrances served. Where two or more similar site arrival points, such as bus stops, serve the same accessible entrance or entrances, both bus stops must be on accessible routes. In addition, the accessible routes must serve all of the accessible entrances on the site. Advisory 206.2.1 Site Arrival Points Exception 2. Access from site arrival points may include vehicular ways. Where a vehicular way, or a portion of a vehicular way, is provided for pedestrian travel, such as within a shopping center or shopping mall parking lot, this exception does not apply. 206.2.2 Within a Site. At least one accessible route shall connect accessible buildings, accessible facilities, accessible elements, and accessible spaces that are on the same site. EXCEPTION: An accessible route shall not be required between accessible buildings, accessible facilities, accessible elements, and accessible spaces if the only means of access between them is a vehicular way not providing pedestrian access. Advisory 206.2.2 Within a Site. An accessible route is required to connect to the boundary of each area of sport activity. Examples of areas of sport activity include: soccer fields, basketball courts, baseball fields, running tracks, skating rinks, and the area surrounding a piece of gymnastic equipment. While the size of an area of sport activity may vary from sport to sport, each includes only the space needed to play. Where multiple sports fields or courts are provided, an accessible route is required to each field or area of sport activity. 206.2.3 Multi-Story Buildings and Facilities. At least one accessible route shall connect each story and mezzanine in multi-story buildings and facilities. Notwithstanding the requirements and exceptions of this section, section 201.1.1 shall apply. EXCEPTIONS: 1.Reserved. 2.Reserved. 3.Reserved. 4.Reserved. 5.Reserved. 6.Reserved. 7.Reserved. 22 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 SCOPING CHAPTER 2: SCOPING REQUIREMENTS Advisory 206.2.3 Multi-Story Buildings and Facilities. Spaces and elements located on a level not required to be served by an accessible route must fully comply with this code. While a mezzanine may be a change in level, it is not a story. If an accessible route is required to connect stories within a building or facility, the accessible route must serve all mezzanines. Advisory 206.2.3 Multi-Story Buildings and Facilities Exceptions. Exceptions 1–7 are preempted by Florida vertical accessibility requirements of s.553.509, F.S., as incorporated in section 201.1.1. Florida requirements may be waived down to the ADA Standards requirements. Note: The following Advisories on the Exceptions to 206.2.3 are provided for consideration when waiving Florida Vertical Accessibility requirements down to ADA Standards for Accessible Design. Advisory 206.2.3 Multi-Story Buildings and Facilities Exception 1. Note that Exception 1 as presented in the 2004 ADAAG must also comply with the elevator exemption criteria of 28 CFR 36.401(d). The elevator exemption is authorized by 28 CFR 36.401(d) and applies only to private entities governed by Title III but not to public entities governed by Title II and 28 CFR, Part 35. Note also that 28 CFR 36.401(d)(2) and (3) provide specific criteria expanding on the criteria of Exception 1 that must be considered in a waiver of Florida vertical accessibility. Advisory 206.2.3 Multi-Story Buildings and Facilities Exception 2. Note that Exception 2 for a required accessible route applies to public entities, is not modified by 28 CFR, Part 35 and parallels the exception for vertical accessibility in s.553.509(1)(c), F.S., and 201.1.1(3). Advisory 206.2.3 Multi-Story Buildings and Facilities Exception 4. Where common use areas are provided for the use of residents, it is presumed that all such common use areas “serve” accessible dwelling units unless use is restricted to residents occupying certain dwelling units. For example, if all residents are permitted to use all laundry rooms, then all laundry rooms “serve” accessible dwelling units. However, if the laundry room on the first floor is restricted to use by residents on the first floor, and the second floor laundry room is for use by occupants of the second floor, then first floor accessible units are “served” only by laundry rooms on the first floor. In this example, an accessible route is not required to the second floor provided that all accessible units and all common use areas serving them are on the first floor. 206.2.3.1 Stairs and Escalators in Existing Buildings. In alterations and additions, where an escalator or stair is provided where none existed previously and major structural modifications are necessary for the installation, an accessible route shall be provided between the levels served by the escalator or stair unless exempted by 206.2.3, Exceptions 1 through 7. 206.2.4 Spaces and Elements. At least one accessible route shall connect accessible building or facility entrances with all accessible spaces and elements within the building or facility which are otherwise connected by a circulation path unless exempted by 206.2.3 Exceptions 1 through 7. Notwithstanding the requirements and exceptions of this section, section 201.1.1 shall apply. EXCEPTIONS: 1.Reserved. 2.Reserved. 3.Reserved. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 23 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 2: SCOPING REQUIREMENTS SCOPING Advisory 206.2.4 Spaces and Elements. Accessible routes must connect all spaces and elements required to be accessible including, but not limited to, raised areas and speaker platforms. Advisory 206.2.4 Spaces and Elements Exceptions. Exceptions 1 – 3 are preempted by Florida vertical accessibility requirements of s.553.509, F.S., as incorporated in section 201.1.1. Florida requirements may be waived down to the ADA Standards requirements. Note: The following ADAAG Advisory on Exceptions 1 to 206.2.4 is retained for consideration when waiving Florida Vertical Accessibility requirements down to ADA Standards for Accessible Design. Advisory 206.2.4 Spaces and Elements Exception 1. The exception does not apply to areas that are likely to be used by members of the public who are not employees of the court such as jury areas, attorney areas, or witness stands. 206.2.5 Restaurants and Cafeterias. In restaurants and cafeterias, an accessible route shall be provided to all dining areas, including raised or sunken dining areas, and outdoor dining areas. Notwithstanding the requirements and exceptions of this section, section 201.1.1 shall apply. EXCEPTIONS: 1.Reserved. 2.Reserved. 3.Reserved. Advisory 206.2.5 Restaurants and Cafeterias Exceptions. Exceptions 1 – 3 are preempted by Florida vertical accessibility requirements of s.553.509, F.S., as incorporated in section 201.1.1. Florida requirements may be waived down to the ADA Standards requirements. Advisory 206.2.5 Restaurants and Cafeterias Exception 2. Examples of “same services” include, but are not limited to, bar service, rooms having smoking and nonsmoking sections, lotto and other table games, carry-out, and buffet service. Examples of “same decor” include, but are not limited to, seating at or near windows and railings with views, areas designed with a certain theme, party and banquet rooms, and rooms where entertainment is provided. 206.2.6 Performance Areas. Where a circulation path directly connects a performance area to an assembly seating area, an accessible route shall directly connect the assembly seating area with the performance area. An accessible route shall be provided from performance areas to ancillary areas or facilities used by performers unless exempted by 206.2.3 Exceptions 1 through 7. Notwithstanding the requirements of this section, section 201.1.1 shall apply. 206.2.7 Press Boxes. Press boxes in assembly areas shall be on an accessible route. Notwithstanding the requirements and exceptions of this section, section 201.1.1 shall apply. EXCEPTIONS: 1. Reserved. 2. Reserved. 24 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 SCOPING CHAPTER 2: SCOPING REQUIREMENTS Advisory 206.2.7 Press Boxes. Exceptions 1 – 3 are preempted by Florida vertical accessibility requirements of s.553.509, F.S., as incorporated in section 201.1.1. Florida requirements may be waived down to the ADA Standards requirements. Advisory 206.2.7 Press Boxes, Exception 2. Where a facility contains multiple assembly areas, the aggregate area of the press boxes in each assembly area is to be calculated separately. For example, if a university has a soccer stadium with three press boxes elevated 12 feet (3660 mm) or more above grade and each press box is 150 square feet (14 m2), then the aggregate area of the soccer stadium press boxes is less than 500 square feet (46 m2) and Exception 2 applies to the soccer stadium. If that same university also has a football stadium with two press boxes elevated 12 feet (3660 mm) or more above grade and one press box is 250 square feet (23 m2), and the second is 275 square feet (26 m2), then the aggregate area of the football stadium press boxes is more than 500 square feet (46 m2) and Exception 2 does not apply to the football stadium. 206.2.8 Employee Work Areas. Common use circulation paths within employee work areas shall comply with 402. EXCEPTIONS: 1. Common use circulation paths within employee work areas that are less than 1000 square feet (93 m2) and defined by permanently installed partitions, counters, casework, or furnishings shall not be required to comply with 402. 2. Common use circulation paths located within employee work areas that are an integral component of work area equipment shall not be required to comply with 402. 3. Common use circulation paths located within exterior employee work areas that are fully exposed to the weather shall not be required to comply with 402. Advisory 206.2.8 Employee Work Areas Exception 1. Modular furniture that is not permanently installed is not directly subject to these requirements. The Department of Justice ADA regulations provide additional guidance regarding the relationship between these requirements and elements that are not part of the built environment. Additionally, the Equal Employment Opportunity Commission (EEOC) implements title I of the ADA which requires non-discrimination in the workplace. EEOC can provide guidance regarding employers’ obligations to provide reasonable accommodations for employees with disabilities. Advisory 206.2.8 Employee Work Areas Exception 2. Large pieces of equipment, such as electric turbines or water pumping apparatus, may have stairs and elevated walkways used for overseeing or monitoring purposes which are physically part of the turbine or pump. However, passenger elevators used for vertical transportation between stories are not considered “work area equipment” as defined in Section 106.5. 206.2.9 Amusement Rides. Amusement rides required to comply with 234 shall provide accessible routes in accordance with 206.2.9. Accessible routes serving amusement rides shall comply with Chapter 4 except as modified by 1002.2. 206.2.9.1 Load and Unload Areas. Load and unload areas shall be on an accessible route. Where load and unload areas have more than one loading or unloading position, at least one loading and unloading position shall be on an accessible route. 206.2.9.2 Wheelchair Spaces, Ride Seats Designed for Transfer, and Transfer Devices. When amusement rides are in the load and unload position, wheelchair spaces complying with 1002.4, amusement ride seats designed for transfer complying with 1002.5, and transfer devices complying with 1002.6 shall be on an accessible route. 206.2.10 Recreational Boating Facilities. Boat slips required to comply with 235.2 and boarding piers at boat launch ramps required to comply with 235.3 shall be on an accessible route. Accessible routes serving recreational boating facilities shall comply with Chapter 4, except as modified by 1003.2. 206.2.11 Bowling Lanes. Where bowling lanes are provided, at least 5 percent, but no fewer than one of each type of bowling lane, shall be on an accessible route. 206.2.12 Court Sports. In court sports, at least one accessible route shall directly connect both sides of the court. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 25 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 2: SCOPING REQUIREMENTS SCOPING 206.2.13 Exercise Machines and Equipment. Exercise machines and equipment required to comply with 236 shall be on an accessible route. 206.2.14 Fishing Piers and Platforms. Fishing piers and platforms shall be on an accessible route. Accessible routes serving fishing piers and platforms shall comply with Chapter 4 except as modified by 1005.1. 206.2.15 Golf Facilities. At least one accessible route shall connect accessible elements and spaces within the boundary of the golf course. In addition, accessible routes serving golf car rental areas; bag drop areas; course weather shelters complying with 238.2.3; course toilet rooms; and practice putting greens, practice teeing grounds, and teeing stations at driving ranges complying with 238.3 shall comply with Chapter 4 except as modified by 1006.2. EXCEPTION: Golf car passages complying with 1006.3 shall be permitted to be used for all or part of accessible routes required by 206.2.15. 206.2.16 Miniature Golf Facilities. Holes required to comply with 239.2, including the start of play, shall be on an accessible route. Accessible routes serving miniature golf facilities shall comply with Chapter 4 except as modified by 1007.2. 206.2.17 Play Areas. Play areas shall provide accessible routes in accordance with 206.2.17. Accessible routes serving play areas shall comply with Chapter 4 except as modified by 1008.2. 206.2.17.1 Ground Level and Elevated Play Components. At least one accessible route shall be provided within the play area. The accessible route shall connect ground level play components required to comply with 240.2.1 and elevated play components required to comply with 240.2.2, including entry and exit points of the play components. 206.2.17.2 Soft Contained Play Structures. Where three or fewer entry points are provided for soft contained play structures, at least one entry point shall be on an accessible route. Where four or more entry points are provided for soft contained play structures, at least two entry points shall be on an accessible route. 206.3 Location. Accessible routes shall coincide with or be located in the same area as general circulation paths. Where circulation paths are interior, required accessible routes shall also be interior. For transportation facilities subject to Department of Transportation regulation 49 CFR 37.21, elements such as ramps, elevators, or other circulation devices, fare vending or other ticketing areas, and fare collection areas shall be placed to minimize the distance which wheelchair users and other persons who cannot negotiate steps may have to travel compared to the general public. Advisory 206.3 Location. The accessible route must be in the same area as the general circulation path. This means that circulation paths, such as vehicular ways designed for pedestrian traffic, walks, and unpaved paths that are designed to be routinely used by pedestrians must be accessible or have an accessible route nearby. Additionally, accessible vertical interior circulation must be in the same area as stairs and escalators, not isolated in the back of the facility. 206.4 Entrances. Entrances shall be provided in accordance with 206.4. Entrance doors, doorways, and gates shall comply with 404 and shall be on an accessible route complying with 402. EXCEPTIONS: 1. Where an alteration includes alterations to an entrance, and the building or facility has another entrance complying with 404 that is on an accessible route, the altered entrance shall not be required to comply with 206.4 unless required by 202.4. 2. Where exceptions for alterations to qualified historic buildings or facilities are permitted by 202.5, no more than one public entrance shall be required to comply with 206.4. Where no public entrance can comply with 206.4 under criteria established in 202.5 Exception, then either an unlocked entrance not used by the public shall comply with 206.4; or a locked entrance complying with 206.4 with a notification system or remote monitoring shall be provided. 206.4.1 Public Entrances. In addition to entrances required by 206.4.2 through 206.4.9, at least 60 percent of all public entrances shall comply with 404. Barriers at common or emergency entrances and exits of business establishments conducting business with the general public that are existing, under construction, or under contract for construction which would prevent a person from using such entrances or exits shall be removed. 26 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 SCOPING CHAPTER 2: SCOPING REQUIREMENTS 206.4.2 Parking Structure Entrances. Where direct access is provided for pedestrians from a parking structure to a building or facility entrance, each direct access to the building or facility entrance shall comply with 404. 206.4.3 Entrances from Tunnels or Elevated Walkways. Where direct access is provided for pedestrians from a pedestrian tunnel or elevated walkway to a building or facility, at least one direct entrance to the building or facility from each tunnel or walkway shall comply with 404. 206.4.4 Transportation Facilities. In addition to the requirements of 206.4.2, 206.4.3, and 206.4.5 through 206.4.9, transportation facilities shall provide entrances in accordance with 206.4.4. 206.4.4.1 Location. In transportation facilities, where different entrances serve different transportation fixed routes or groups of fixed routes, at least one public entrance serving each fixed route or group of fixed routes shall comply with 404. EXCEPTION: Entrances to key stations and existing intercity rail stations retrofitted in accordance with 49 CFR 37.49 or 49 CFR 37.51 shall not be required to comply with 206.4.4.1. 206.4.4.2 Direct Connections. Direct connections to other facilities shall provide an accessible route complying with 404 from the point of connection to boarding platforms and all transportation system elements required to be accessible. Any elements provided to facilitate future direct connections shall be on an accessible route connecting boarding platforms and all transportation system elements required to be accessible. EXCEPTION: In key stations and existing intercity rail stations, existing direct connections shall not be required to comply with 404. 206.4.4.3 Key Stations and Intercity Rail Stations. Key stations and existing intercity rail stations required by Subpart C of 49 CFR part 37 to be altered, shall have at least one entrance complying with 404. 206.4.5 Tenant Spaces. At least one accessible entrance to each tenancy in a facility shall comply with 404. EXCEPTION: Self-service storage facilities not required to comply with 225.3 shall not be required to be on an accessible route. 206.4.6 Residential Dwelling Unit Primary Entrance. In residential dwelling units, at least one primary entrance shall comply with 404. The primary entrance to a residential dwelling unit shall not be to a bedroom. 206.4.7 Restricted Entrances. Where restricted entrances are provided to a building or facility, at least one restricted entrance to the building or facility shall comply with 404. 206.4.8 Service Entrances. If a service entrance is the only entrance to a building or to a tenancy in a facility, that entrance shall comply with 404. 206.4.9 Entrances for Inmates or Detainees. Where entrances used only by inmates or detainees and security personnel are provided at judicial facilities, detention facilities, or correctional facilities, at least one such entrance shall comply with 404. 206.5 Doors, Doorways, and Gates. Doors, doorways, and gates providing user passage shall be provided in accordance with 206.5. Barriers at common or emergency entrances and exits of business establishments conducting business with the general public that are existing, under construction, or under contract for construction which would prevent a person from using such entrances or exits shall be removed. 206.5.1 Entrances. Each entrance to a building or facility required to comply with 206.4 shall have at least one door, doorway, or gate complying with 404. 206.5.2 Rooms and Spaces. Within a building or facility, at least one door, doorway, or gate serving each room or space complying with these requirements shall comply with 404. 206.5.3 Transient Lodging Facilities. In transient lodging facilities, entrances, doors, and doorways providing user passage into and within guest rooms that are not required to provide mobility features complying with 806.2 shall comply with 404.2.3. EXCEPTION: Shower and sauna doors in guest rooms that are not required to provide mobility features complying with 806.2 shall not be required to comply with 404.2.3. 206.5.4 Residential Dwelling Units. In residential dwelling units required to provide mobility features complying with 809.2 through 809.4, all doors and doorways providing user passage shall comply with 404. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 27 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 2: SCOPING REQUIREMENTS SCOPING 206.6 Elevators. Elevators provided for passengers shall comply with 407. Where multiple elevators are provided, each elevator shall comply with 407. EXCEPTIONS: 1. In a building or facility permitted to use the exceptions to 206.2.3 or permitted by 206.7 to use a platform lift, elevators complying with 408 shall be permitted. 2. Elevators complying with 408 or 409 shall be permitted in multi-story residential dwelling units. 206.6.1 Existing Elevators. Where elements of existing elevators are altered, the same element shall also be altered in all elevators that are programmed to respond to the same hall call control as the altered elevator and shall comply with the requirements of 407 for the altered element. 206.7 Platform Lifts. Platform lifts shall comply with 410. Platform lifts shall be permitted as a component of an accessible route in new construction in accordance with 206.7. Platform lifts shall be permitted as a component of an accessible route in an existing building or facility. 206.7.1 Performance Areas and Speakers’ Platforms. Platform lifts shall be permitted to provide accessible routes to performance areas and speakers’ platforms. 206.7.2 Wheelchair Spaces. Platform lifts shall be permitted to provide an accessible route to comply with the wheelchair space dispersion and line-of-sight requirements of 221 and 802. 206.7.3 Incidental Spaces. Platform lifts shall be permitted to provide an accessible route to incidental spaces which are not public use spaces and which are occupied by five persons maximum. 206.7.4 Judicial Spaces. Platform lifts shall be permitted to provide an accessible route to: jury boxes and witness stands; raised courtroom stations including judges’ benches, clerks’ stations, bailiffs’ stations, deputy clerks’ stations, and court reporters’ stations; and to depressed areas such as the well of a court. 206.7.5 Existing Site Constraints. Platform lifts shall be permitted where existing exterior site constraints make use of a ramp or elevator infeasible. Advisory 206.7.5 Existing Site Constraints. This exception applies where topography or other similar existing site constraints necessitate the use of a platform lift as the only feasible alternative. While the site constraint must reflect exterior conditions, the lift can be installed in the interior of a building. For example, a new building constructed between and connected to two existing buildings may have insufficient space to coordinate floor levels and also to provide ramped entry from the public way. In this example, an exterior or interior platform lift could be used to provide an accessible entrance or to coordinate one or more interior floor levels. 206.7.6 Guest Rooms and Residential Dwelling Units. Platform lifts shall be permitted to connect levels within transient lodging guest rooms required to provide mobility features complying with 806.2 or residential dwelling units required to provide mobility features complying with 809.2 through 809.4. 206.7.7 Amusement Rides. Platform lifts shall be permitted to provide accessible routes to load and unload areas serving amusement rides. 206.7.8 Play Areas. Platform lifts shall be permitted to provide accessible routes to play components or soft contained play structures. 206.7.9 Team or Player Seating. Platform lifts shall be permitted to provide accessible routes to team or player seating areas serving areas of sport activity. Advisory 206.7.9 Team or Player Seating. While the use of platform lifts is allowed, ramps are recommended to provide access to player seating areas serving an area of sport activity. 206.7.10 Recreational Boating Facilities and Fishing Piers and Platforms. Platform lifts shall be permitted to be used instead of gangways that are part of accessible routes serving recreational boating facilities and fishing piers and platforms. 206.8 Security Barriers. Security barriers, including but not limited to, security bollards and security check points, shall not obstruct a required accessible route or accessible means of egress. EXCEPTION: Where security barriers incorporate elements that cannot comply with these requirements such as certain metal detectors, fluoroscopes, or other similar devices, the accessible route shall be permitted to be located adjacent to security screening devices. The accessible route shall permit persons with disabilities passing 28 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 SCOPING CHAPTER 2: SCOPING REQUIREMENTS around security barriers to maintain visual contact with their personal items to the same extent provided others passing through the security barrier. 207 ACCESSIBLE MEANS OF EGRESS 207.1 General. Means of egress shall comply with section 1003.2.13 of the International Building Code (2000 edition and 2001 Supplement) or section 1007 of the International Building Code (2003 edition) (incorporated by reference, see “Referenced Standards” in Chapter 1). EXCEPTIONS: 1. Where means of egress are permitted by local building or life safety codes to share a common path of egress travel, accessible means of egress shall be permitted to share a common path of egress travel. 2. Areas of refuge shall not be required in detention and correctional facilities. 207.1.1 Barriers at common or emergency entrances and exits of business establishments conducting business with the general public that are existing, under construction, or under contract for construction which would prevent a person from using such entrances or exits shall be removed. 207.2 Platform Lifts. Standby power shall be provided for platform lifts permitted by section 1003.2.13.4 of the International Building Code (2000 edition and 2001 Supplement) or section 1007.5 of the International Building Code (2003 edition) (incorporated by reference, see “Referenced Standards” in Chapter 1) to serve as a part of an accessible means of egress. 208 PARKING SPACES 208.1 General. Where parking spaces are provided, parking spaces shall be provided in accordance with 208. See section 502.5 requirements for van parking in structures. EXCEPTION: Parking spaces used exclusively for buses, trucks, other delivery vehicles, law enforcement vehicles, or vehicular impound shall not be required to comply with 208 provided that lots accessed by the public are provided with a passenger loading zone complying with 503. 208.1.1 The removal of architectural barriers from a parking facility in accordance with 28 C.F.R. Section 36.304 or with Section 553.508, F. S., must comply with this section unless compliance would cause the barrier removal not to be readily achievable. If compliance would cause the barrier removal not to be readily achievable, a facility may provide parking spaces at alternative locations for persons who have disabilities and provide appropriate signage directing such persons to the alternative parking if readily achievable. The facility may not reduce the required number or dimensions of those spaces or unreasonably increase the length of the accessible route from a parking space to the facility. The removal of an architectural barrier must not create a significant risk to the health or safety of a person who has a disability or to that of others. 208.1.2 A facility that is making alterations under section 202 as required by s.303(a) of the Americans with Disabilites Act of 1990 must comply with section 208 to the maximum extent feasible. If compliance with parking location requirements is not feasible, the facility may provide parking spaces at alternative locations for persons who have disabilities and provide appropriate signage directing such persons to alternative parking. The facility may not reduce the required number or dimensions of those spaces, or unnecessarily increase the length of the accessible route from a parking space to the facility. The alteration must not create a significant risk to the health or safety of a person who has a disability or to others. 208.2 Minimum Number. Parking spaces complying with 502 shall be provided in accordance with Table 208.2 except as required by 208.2.1, 208.2.2, and 208.2.3. Where more than one parking facility is provided on a site, the number of accessible spaces provided on the site shall be calculated according to the number of spaces required for each parking facility. The number of parking spaces for persons who have disabilities must be increased on the basis of demonstrated and documented need. Advisory 208.2 Minimum Number. The term “parking facility” is used in Section 208.2 instead of the term “parking lot” so that it is clear that both parking lots and parking structures are required to comply with this section. The number of parking spaces required to be accessible is to be calculated separately for each parking facility; the required number is not to be based on the total number of parking spaces provided in all of the parking facilities provided on the site. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 29 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 2: SCOPING REQUIREMENTS SCOPING TABLE 208.2 PARKING SPACES Total Number of Parking Spaces Provided in Parking Facility Minimum Number of Required Accessible Parking Spaces 1 to 25 26 to 50 51 to 75 76 to 100 101 to 150 151 to 200 201 to 300 301 to 400 401 to 500 501 to 1000 1 2 3 4 5 6 7 8 9 2 percent of total 20, plus 1 for each 100, or fraction thereof, over 1000 1001 and over 208.2.1 Hospital Outpatient Facilities. Ten percent of patient and visitor parking spaces provided to serve hospital outpatient facilities shall comply with 502. Advisory 208.2.1 Hospital Outpatient Facilities. The term “outpatient facility” is not defined in this code but is intended to cover facilities or units that are located in hospitals and that provide regular and continuing medical treatment without an overnight stay. Doctors’ offices, independent clinics, or other facilities not located in hospitals are not considered hospital outpatient facilities for purposes of this code. 208.2.2 Rehabilitation Facilities and Outpatient Physical Therapy Facilities. Twenty percent of patient and visitor parking spaces provided to serve rehabilitation facilities specializing in treating conditions that affect mobility and outpatient physical therapy facilities shall comply with 502. Advisory 208.2.2 Rehabilitation Facilities and Outpatient Physical Therapy Facilities. Conditions that affect mobility include conditions requiring the use or assistance of a brace, cane, crutch, prosthetic device, wheelchair, or powered mobility aid; arthritic, neurological, or orthopedic conditions that severely limit one’s ability to walk; respiratory diseases and other conditions which may require the use of portable oxygen; and cardiac conditions that impose significant functional limitations. 208.2.3 Residential Facilities. Parking spaces provided to serve residential facilities shall comply with 208.2.3. 208.2.3.1 Parking for Residents. Where at least one parking space is provided for each residential dwelling unit, at least one parking space complying with 502 shall be provided for each residential dwelling unit required to provide mobility features complying with 809.2 through 809.4. 208.2.3.2 Additional Parking Spaces for Residents. Where the total number of parking spaces provided for each residential dwelling unit exceeds one parking space per residential dwelling unit, 2 percent, but no fewer than one space, of all the parking spaces not covered by 208.2.3.1 shall comply with 502. 208.2.3.3 Parking for Guests, Employees, and Other Non-Residents. Where parking spaces are provided for persons other than residents, parking shall be provided in accordance with Table 208.2. 208.2.4 Van Parking Spaces. Where van parking is provided pursuant to section 502.2, for every six or fraction of six parking spaces required by 208.2 to comply with 502, at least one shall be a van parking space complying with 502. 208.2.5 Parking Spaces Provided by State Agencies and Political Subdivisions. 30 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 SCOPING CHAPTER 2: SCOPING REQUIREMENTS 208.2.5.1 There must be one accessible parking space in the immediate vicinity of a publicly owned or leased building that houses a governmental entity or a political subdivision, including, but not limited to, state office buildings and courthouses, if parking for the public is not provided on the premises of the building. 208.2.5.2 There must be one accessible parking space for each 150 metered on-street parking spaces provided by state agencies and political subdivisions. EXCEPTION: State agencies and political subdivisions having jurisdiction over street parking or publicly owned or operated parking facilities are not required to provide a greater right-of-way width than would otherwise be planned under regulations, guidelines, or practices normally applied to new development. 208.3 Location. Parking facilities shall comply with 208.3. 208.3.1 General. Designated accessible spaces shall be designed and marked for the exclusive use of those individuals who have a severe physical disability and have permanent or temporary mobility problems that substantially impair their ability to ambulate and who have been issued either a disabled parking permit under s. 316.1958 or s. 320.0848 or a license plate under s. 320.084, s. 320.0842, s. 320.0843, or s. 320.0845. Parking spaces complying with 502 that serve a particular building or facility shall be located on the shortest accessible route from parking to an entrance complying with 206.4. All spaces must be located on an accessible route that is at least 44 inches (1118 mm) wide and so that users are not compelled to walk or wheel behind parked vehicles except behind his or her own vehicle. Where parking serves more than one accessible entrance, parking spaces complying with 502 shall be dispersed and located on the shortest accessible route to the accessible entrances. If there are multiple entrances for multiple retail stores the parking spaces must be dispersed to provide parking at the nearest accessible entrance. In parking facilities that do not serve a particular building or facility, parking spaces complying with 502 shall be located on the shortest accessible route to an accessible pedestrian entrance of the parking facility. EXCEPTIONS: 1. All van parking spaces shall be permitted to be grouped on one level within a multi-story parking facility. 2. Parking spaces shall be permitted to be located in different parking facilities if substantially equivalent or greater accessibility is provided in terms of distance from an accessible entrance or entrances, parking fee, and user convenience. 3. If a theme park or entertainment complex provides parking in several lots or areas from which access to the theme park or entertainment complex is provided, a single lot or area may be designated for parking by persons who have disabilities, if the lot or area is located on the shortest accessible route to an accessible entrance to the theme park or entertainment complex or to transportation to such an accessible entrance. 4. A theme park or entertainment complex in which are provided continuous attendant services for directing individuals to marked accessible parking spaces or designated lots for parking by persons who have disabilities, may, in lieu of the required parking space design, provide parking spaces that comply with Sections 208 and 502 of the ADA Standards for Accessible Design. Advisory 208.3.1 General Exception 2. Factors that could affect “user convenience” include, but are not limited to, protection from the weather, security, lighting, and comparative maintenance of the alternative parking site. Florida law adds dispersion requirements for accessible parking where multiple parking areas are provided and for multiple entrances for multiple retail stores. Accessible routes from accessible parking to accessible entrances are required to be 44 inches wide minimum. Exceptions are established for the Florida specific requirements only (indicated by gray shading) for theme parks and entertainment complexes by added exceptions 3 and 4. 208.3.2 Residential Facilities. In residential facilities containing residential dwelling units required to provide mobility features complying with 809.2 through 809.4, parking spaces provided in accordance with 208.2.3.1 shall be located on the shortest accessible route to the residential dwelling unit entrance they serve. Spaces provided in accordance with 208.2.3.2 shall be dispersed throughout all types of parking provided for the residential dwelling units. EXCEPTION: Parking spaces provided in accordance with 208.2.3.2 shall not be required to be dispersed throughout all types of parking if substantially equivalent or greater accessibility is provided in terms of distance from an accessible entrance, parking fee, and user convenience. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 31 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 2: SCOPING REQUIREMENTS SCOPING Advisory 208.3.2 Residential Facilities Exception. Factors that could affect “user convenience” include, but are not limited to, protection from the weather, security, lighting, and comparative maintenance of the alternative parking site. 209 PASSENGER LOADING ZONES AND BUS STOPS 209.1 General. Passenger loading zones shall be provided in accordance with 209. 209.2 Type. Where provided, passenger loading zones shall comply with 209.2. 209.2.1 Passenger Loading Zones. Passenger loading zones, except those required to comply with 209.2.2 and 209.2.3, shall provide at least one passenger loading zone complying with 503 in every continuous 100 linear feet (30 m) of loading zone space, or fraction thereof. 209.2.2 Bus Loading Zones. In bus loading zones restricted to use by designated or specified public transportation vehicles, each bus bay, bus stop, or other area designated for lift or ramp deployment shall comply with 810.2. Advisory 209.2.2 Bus Loading Zones. The terms “designated public transportation” and “specified public transportation” are defined by the Department of Transportation at 49 CFR 37.3 in regulations implementing the Americans with Disabilities Act. These terms refer to public transportation services provided by public or private entities, respectively. For example, designated public transportation vehicles include buses and vans operated by public transit agencies, while specified public transportation vehicles include tour and charter buses, taxis and limousines, and hotel shuttles operated by private entities. 209.2.3 On-Street Bus Stops. On-street bus stops shall comply with 810.2 to the maximum extent practicable. 209.3 Medical Care and Long-Term Care Facilities. At least one passenger loading zone complying with 503 shall be provided at an accessible entrance to licensed medical care and licensed long-term care facilities where the period of stay exceeds twenty-four hours. 209.4 Valet Parking. Parking facilities that provide valet parking services shall provide at least one passenger loading zone complying with 503. 209.5 Mechanical Access Parking Garages. Mechanical access parking garages shall provide at least one passenger loading zone complying with 503 at vehicle drop-off and vehicle pick-up areas. 210 STAIRWAYS 210.1 General. Interior and exterior stairs that are part of a means of egress shall comply with 504. EXCEPTIONS: 1. In detention and correctional facilities, stairs that are not located in public use areas shall not be required to comply with 504. 2. In alterations, stairs between levels that are connected by an accessible route shall not be required to comply with 504, except that handrails complying with 505 shall be provided when the stairs are altered. 3. In assembly areas, aisle stairs shall not be required to comply with 504. 4. Stairs that connect play components shall not be required to comply with 504. Advisory 210.1 General. Although these requirements do not mandate handrails on stairs that are not part of a means of egress, State or local building codes may require handrails or guards. 32 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 SCOPING CHAPTER 2: SCOPING REQUIREMENTS 211 DRINKING FOUNTAINS 211.1 General. Where drinking fountains are provided on an exterior site, on a floor, or within a secured area they shall be provided in accordance with 211. EXCEPTION: In detention or correctional facilities, drinking fountains only serving holding or housing cells not required to comply with 232 shall not be required to comply with 211. 211.2 Minimum Number. No fewer than two drinking fountains shall be provided. One drinking fountain shall comply with 602.1 through 602.6 and one drinking fountain shall comply with 602.7. EXCEPTION: Where a single drinking fountain complies with 602.1 through 602.6 and 602.7, it shall be permitted to be substituted for two separate drinking fountains. 211.3 More Than Minimum Number. Where more than the minimum number of drinking fountains specified in 211.2 are provided, 50 percent of the total number of drinking fountains provided shall comply with 602.1 through 602.6, and 50 percent of the total number of drinking fountains provided shall comply with 602.7. EXCEPTION: Where 50 percent of the drinking fountains yields a fraction, 50 percent shall be permitted to be rounded up or down provided that the total number of drinking fountains complying with 211 equals 100 percent of drinking fountains. 212 KITCHENS, KITCHENETTES, AND SINKS 212.1 General. Where provided, kitchens, kitchenettes, and sinks shall comply with 212. 212.2 Kitchens and Kitchenettes. Kitchens and kitchenettes shall comply with 804. 212.3 Sinks. Where sinks are provided, at least 5 percent, but no fewer than one, of each type provided in each accessible room or space shall comply with 606. EXCEPTION: Mop or service sinks shall not be required to comply with 212.3. 213 TOILET FACILITIES AND BATHING FACILITIES 213.1 General. Where toilet facilities and bathing facilities are provided, they shall comply with 213. Where toilet facilities and bathing facilities are provided in facilities permitted by 206.2.3 Exceptions 1 and 2 not to connect stories by an accessible route, toilet facilities and bathing facilities shall be provided on a story connected by an accessible route to an accessible entrance. 213.2 Toilet Rooms and Bathing Rooms. Where toilet rooms are provided, each toilet room shall comply with 603. Where bathing rooms are provided, each bathing room shall comply with 603. EXCEPTIONS: 1. In alterations where it is technically infeasible to comply with 603, altering existing toilet or bathing rooms shall not be required where a single unisex toilet room or bathing room complying with 213.2.1 is provided and located in the same area and on the same floor as existing in accessible toilet or bathing rooms. 2. Where exceptions for alterations to qualified historic buildings or facilities are permitted by 202.5, no fewer than one toilet room for each sex complying with 603 or one unisex toilet room complying with 213.2.1 shall be provided. 3. Where multiple single user portable toilet or bathing units are clustered at a single location, no more than 5 percent of the toilet units and bathing units at each cluster shall be required to comply with 603. Portable toilet units and bathing units complying with 603 shall be identified by the International Symbol of Accessibility complying with 703.7.2.1. 4. Where multiple single user toilet rooms are clustered at a single location, no more than 50 percent of the single user toilet rooms for each use at each cluster shall be required to comply with 603. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 33 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 2: SCOPING REQUIREMENTS SCOPING Advisory 213.2 Toilet Rooms and Bathing Rooms. These requirements allow the use of unisex (or single-user) toilet rooms in alterations when technical infeasibility can be demonstrated. Unisex toilet rooms benefit people who use opposite sex personal care assistants. For this reason, it is advantageous to install unisex toilet rooms in addition to accessible single-sex toilet rooms in new facilities. Advisory 213.2 Toilet Rooms and Bathing Rooms Exceptions 3 and 4. A “cluster” is a group of toilet rooms proximate to one another. Generally, toilet rooms in a cluster are within sight of, or adjacent to, one another. 213.2.1 Unisex (Single-Use or Family) Toilet and Unisex Bathing Rooms. Unisex toilet rooms shall contain not more than one lavatory, and two water closets without urinals or one water closet and one urinal. Unisex bathing rooms shall contain one shower or one shower and one bathtub, one lavatory, and one water closet. Doors to unisex toilet rooms and unisex bathing rooms shall have privacy latches. 213.3 Plumbing Fixtures and Accessories. Plumbing fixtures and accessories provided in a toilet room or bathing room required to comply with 213.2 shall comply with 213.3. 213.3.1 Toilet Compartments. Where toilet compartments are provided, at least one toilet compartment shall comply with 604.8.1. In addition to the compartment required to comply with 604.8.1, at least one compartment shall comply with 604.8.2 where six or more toilet compartments are provided, or where the combination of urinals and water closets totals six or more fixtures. Advisory 213.3.1 Toilet Compartments. A toilet compartment is a partitioned space that is located within a toilet room, and that normally contains no more than one water closet. A toilet compartment may also contain a lavatory. A lavatory is a sink provided for hand washing. Fullheight partitions and door assemblies can comprise toilet compartments where the minimum required spaces are provided within the compartment. 213.3.2 Water Closets. Where water closets are provided, at least one shall comply with 604. 213.3.3 Urinals. Where more than one urinal is provided, at least one shall comply with 605. 213.3.4 Lavatories. Where lavatories are provided, at least one shall comply with 606 and shall not be located in a toilet compartment. 213.3.5 Mirrors. Where mirrors are provided, at least one shall comply with 603.3. 213.3.6 Bathing Facilities. Where bathtubs or showers are provided, at least one bathtub complying with 607 or at least one shower complying with 608 shall be provided. 213.3.7 Coat Hooks and Shelves. Where coat hooks or shelves are provided in toilet rooms without toilet compartments, at least one of each type shall comply with 603.4. Where coat hooks or shelves are provided in toilet compartments, at least one of each type complying with 604.8.3 shall be provided in toilet compartments required to comply with 213.3.1. Where coat hooks or shelves are provided in bathing facilities, at least one of each type complying with 603.4 shall serve fixtures required to comply with 213.3.6. 214 WASHING MACHINES AND CLOTHES DRYERS 214.1 General. Where provided, washing machines and clothes dryers shall comply with 214. 214.2 Washing Machines. Where three or fewer washing machines are provided, at least one shall comply with 611. Where more than three washing machines are provided, at least two shall comply with 611. 214.3 Clothes Dryers. Where three or fewer clothes dryers are provided, at least one shall comply with 611. Where more than three clothes dryers are provided, at least two shall comply with 611. 215 FIRE ALARM SYSTEMS 215.1 General. Where fire alarm systems provide audible alarm coverage, alarms shall comply with 215. EXCEPTION: In existing facilities, visible alarms shall not be required except where an existing fire alarm system is upgraded or replaced, or a new fire alarm system is installed. 34 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 SCOPING CHAPTER 2: SCOPING REQUIREMENTS Advisory 215.1 General. Unlike audible alarms, visible alarms must be located within the space they serve so that the signal is visible. Facility alarm systems (other than fire alarm systems) such as those used for tornado warnings and other emergencies are not required to comply with the technical criteria for alarms in Section 702. Every effort should be made to ensure that such alarms can be differentiated in their signal from fire alarms systems and that people who need to be notified of emergencies are adequately safeguarded. Consult local fire departments and prepare evacuation plans taking into consideration the needs of every building occupant, including people with disabilities. 215.2 Public and Common Use Areas. Alarms in public use areas and common use areas shall comply with 702. 215.3 Employee Work Areas. Where employee work areas have audible alarm coverage, the wiring system shall be designed so that visible alarms complying with 702 can be integrated into the alarm system. 215.4 Transient Lodging. Guest rooms required to comply with 224.4 shall provide alarms complying with 702. 215.5 Residential Facilities. Where provided in residential dwelling units required to comply with 809.5, alarms shall comply with 702. 216 SIGNS 216.1 General. Signs shall be provided in accordance with 216 and shall comply with 703. EXCEPTIONS: 1. Building directories, menus, seat and row designations in assembly areas, occupant names, building addresses, and company names and logos shall not be required to comply with 216. 2. In parking facilities, signs shall not be required to comply with 216.2, 216.3, and 216.6 through 216.12. 3. Temporary, 7 days or less, signs shall not be required to comply with 216. 4. In detention and correctional facilities, signs not located in public use areas shall not be required to comply with 216. 216.2 Designations. Interior and exterior signs identifying permanent rooms and spaces shall comply with 703.1, 703.2, and 703.5. Where pictograms are provided as designations of permanent interior rooms and spaces, the pictograms shall comply with 703.6 and shall have text descriptors complying with 703.2 and 703.5. EXCEPTION: Exterior signs that are not located at the door to the space they serve shall not be required to comply with 703.2. Advisory 216.2 Designations. Section 216.2 applies to signs that provide designations, labels, or names for interior rooms or spaces where the sign is not likely to change over time. Examples include interior signs labeling restrooms, room and floor numbers or letters, and room names. Tactile text descriptors are required for pictograms that are provided to label or identify a permanent room or space. Pictograms that provide information about a room or space, such as “no smoking,” occupant logos, and the International Symbol of Accessibility, are not required to have text descriptors. 216.3 Directional and Informational Signs. Signs that provide direction to or information about interior spaces and facilities of the site shall comply with 703.5. Advisory 216.3 Directional and Informational Signs. Information about interior spaces and facilities includes rules of conduct, occupant load, and similar signs. Signs providing direction to rooms or spaces include those that identify egress routes. 216.4 Means of Egress. Signs for means of egress shall comply with 216.4. 216.4.1 Exit Doors. Doors at exit passageways, exit discharge, and exit stairways shall be identified by tactile signs complying with 703.1, 703.2, and 703.5. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 35 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 2: SCOPING REQUIREMENTS SCOPING Advisory 216.4.1 Exit Doors. An exit passageway is a horizontal exit component that is separated from the interior spaces of the building by fire-resistance-rated construction and that leads to the exit discharge or public way. The exit discharge is that portion of an egress system between the termination of an exit and a public way. 216.4.2 Areas of Refuge. Signs required by section 1003.2.13.5.4 of the International Building Code (2000 edition) or section 1007.6.4 of the International Building Code (2003 edition) (incorporated by reference, see “Referenced Standards” in Chapter 1) to provide instructions in areas of refuge shall comply with 703.5. 216.4.3 Directional Signs. Signs required by section 1003.2.13.6 of the International Building Code (2000 edition) or section 1007.7 of the International Building Code (2003 edition) (incorporated by reference, see “Referenced Standards” in Chapter 1) to provide directions to accessible means of egress shall comply with 703.5. 216.5 Parking. Parking spaces complying with 502 shall be identified by signs complying with 502.6. EXCEPTIONS: 1. Reserved. 2. In residential facilities, where parking spaces are assigned to specific residential dwelling units, identification of accessible parking spaces shall not be required. 216.6 Entrances. Where not all entrances comply with 404, entrances complying with 404 shall be identified by the International Symbol of Accessibility complying with 703.7.2.1. Directional signs complying with 703.5 that indicate the location of the nearest entrance complying with 404 shall be provided at entrances that do not comply with 404. Advisory 216.6 Entrances. Where a directional sign is required, it should be located to minimize backtracking. In some cases, this could mean locating a sign at the beginning of a route, not just at the inaccessible entrances to a building. 216.7 Elevators. Where existing elevators do not comply with 407, elevators complying with 407 shall be clearly identified with the International Symbol of Accessibility complying with 703.7.2.1. 216.8 Toilet Rooms and Bathing Rooms. Where existing toilet rooms or bathing rooms do not comply with 603, directional signs indicating the location of the nearest toilet room or bathing room complying with 603 within the facility shall be provided. Signs shall comply with 703.5 and shall include the International Symbol of Accessibility complying with 703.7.2.1. Where existing toilet rooms or bathing rooms do not comply with 603, the toilet rooms or bathing rooms complying with 603 shall be identified by the International Symbol of Accessibility complying with 703.7.2.1. Where clustered single user toilet rooms or bathing facilities are permitted to use exceptions to 213.2, toilet rooms or bathing facilities complying with 603 shall be identified by the International Symbol of Accessibility complying with 703.7.2.1 unless all toilet rooms and bathing facilities comply with 603. 216.9 TTYs. Identification and directional signs for public TTYs shall be provided in accordance with 216.9. 216.9.1 Identification Signs. Public TTYs shall be identified by the International Symbol of TTY complying with 703.7.2.2. 216.9.2 Directional Signs. Directional signs indicating the location of the nearest public TTY shall be provided at all banks of public pay telephones not containing a public TTY. In addition, where signs provide direction to public pay telephones, they shall also provide direction to public TTYs. Directional signs shall comply with 703.5 and shall include the International Symbol of TTY complying with 703.7.2.2. 216.10 Assistive Listening Systems. Each assembly area required by 219 to provide assistive listening systems shall provide signs informing patrons of the availability of the assistive listening system. Assistive listening signs shall comply with 703.5 and shall include the International Symbol of Access for Hearing Loss complying with 703.7.2.4. EXCEPTION: Where ticket offices or windows are provided, signs shall not be required at each assembly area provided that signs are displayed at each ticket office or window informing patrons of the availability of assistive listening systems. 216.11 Check-Out Aisles. Where more than one check-out aisle is provided, check-out aisles complying with 904.3 shall be identified by the International Symbol of Accessibility complying with 703.7.2.1. Where check-out aisles are identified by numbers, letters, or functions, signs identifying check-out aisles complying with 904.3 shall be located in the same location as the check-out aisle identification. 36 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 SCOPING CHAPTER 2: SCOPING REQUIREMENTS EXCEPTION: Where all check-out aisles serving a single function comply with 904.3, signs complying with 703.7.2.1 shall not be required. 216.12 Amusement Rides. Signs identifying the type of access provided on amusement rides shall be provided at entries to queues and waiting lines. In addition, where accessible unload areas also serve as accessible load areas, signs indicating the location of the accessible load and unload areas shall be provided at entries to queues and waiting lines. Advisory 216.12 Amusement Rides. Amusement rides designed primarily for children, amusement rides that are controlled or operated by the rider, and amusement rides without seats, are not required to provide wheelchair spaces, transfer seats, or transfer systems, and need not meet the sign requirements in 216.12. The load and unload areas of these rides must, however, be on an accessible route and must provide turning space. 217 TELEPHONES 217.1 General. Where coin-operated public pay telephones, coinless public pay telephones, public closed-circuit telephones, public courtesy phones, or other types of public telephones are provided, public telephones shall be provided in accordance with 217 for each type of public telephone provided. For purposes of this section, a bank of telephones shall be considered to be two or more adjacent telephones. Advisory 217.1 General. These requirements apply to all types of public telephones including courtesy phones at airports and rail stations that provide a free direct connection to hotels, transportation services, and tourist attractions. 217.2 Wheelchair Accessible Telephones. Where public telephones are provided, wheelchair accessible telephones complying with 704.2 shall be provided in accordance with Table 217.2. EXCEPTION: Drive-up only public telephones shall not be required to comply with 217.2. TABLE 217.2 WHEELCHAIR ACCESSIBLE TELEPHONES Number of Telephones Provided on a Floor, Level, or Exterior Site Minimum Number of Required Wheelchair Accessible Telephones 1 or more single units 1 bank 2 or more banks 1 per floor, level, and exterior site 1 per floor, level, and exterior site 1 per bank 217.3 Volume Controls. All public telephones shall have volume controls complying with 704.3. 217.4 TTYs. TTYs complying with 704.4 shall be provided in accordance with 217.4. Advisory 217.4 TTYs. Separate requirements are provided based on the number of public pay telephones provided at a bank of telephones, within a floor, a building, or on a site. In some instances one TTY can be used to satisfy more than one of these requirements. For example, a TTY required for a bank can satisfy the requirements for a building. However, the requirement for at least one TTY on an exterior site cannot be met by installing a TTY in a bank inside a building. Consideration should be given to phone systems that can accommodate both digital and analog transmissions for compatibility with digital and analog TTYs. 217.4.1 Bank Requirement. Where four or more public pay telephones are provided at a bank of telephones, at least one public TTY complying with 704.4 shall be provided at that bank. EXCEPTION: TTYs shall not be required at banks of telephones located within 200 feet (61 m) of, and on the same floor as, a bank containing a public TTY. 217.4.2 Floor Requirement. TTYs in public buildings shall be provided in accordance with 217.4.2.1. TTYs in private buildings shall be provided in accordance with 217.4.2.2. 217.4.2.1 Public Buildings. Where at least one public pay telephone is provided on a floor of a public building, at least one public TTY shall be provided on that floor. 217.4.2.2 Private Buildings. Where four or more public pay telephones are provided on a floor of a private building, at least one public TTY shall be provided on that floor. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 37 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 2: SCOPING REQUIREMENTS SCOPING 217.4.3 Building Requirement. TTYs in public buildings shall be provided in accordance with 217.4.3.1. TTYs in private buildings shall be provided in accordance with 217.4.3.2. 217.4.3.1 Public Buildings. Where at least one public pay telephone is provided in a public building, at least one public TTY shall be provided in the building. Where at least one public pay telephone is provided in a public use area of a public building, at least one public TTY shall be provided in the public building in a public use area. 217.4.3.2 Private Buildings. Where four or more public pay telephones are provided in a private building, at least one public TTY shall be provided in the building. 217.4.4 Exterior Site Requirement. Where four or more public pay telephones are provided on an exterior site, at least one public TTY shall be provided on the site. 217.4.5 Rest Stops, Emergency Roadside Stops, and Service Plazas. Where at least one public pay telephone is provided at a public rest stop, emergency roadside stop, or service plaza, at least one public TTY shall be provided. 217.4.6 Hospitals. Where at least one public pay telephone is provided serving a hospital emergency room, hospital recovery room, or hospital waiting room, at least one public TTY shall be provided at each location. 217.4.7 Transportation Facilities. In transportation facilities, in addition to the requirements of 217.4.1 through 217.4.4, where at least one public pay telephone serves a particular entrance to a bus or rail facility, at least one public TTY shall be provided to serve that entrance. In airports, in addition to the requirements of 217.4.1 through 217.4.4, where four or more public pay telephones are located in a terminal outside the security areas, a concourse within the security areas, or a baggage claim area in a terminal, at least one public TTY shall be provided in each location. 217.4.8 Detention and Correctional Facilities. In detention and correctional facilities, where at least one pay telephone is provided in a secured area used only by detainees or inmates and security personnel, at least one TTY shall be provided in at least one secured area. 217.5 Shelves for Portable TTYs. Where a bank of telephones in the interior of a building consists of three or more public pay telephones, at least one public pay telephone at the bank shall be provided with a shelf and an electrical outlet in accordance with 704.5. EXCEPTIONS: 1. Secured areas of detention and correctional facilities where shelves and outlets are prohibited for purposes of security or safety shall not be required to comply with 217.5. 2. The shelf and electrical outlet shall not be required at a bank of telephones with a TTY. 218 TRANSPORTATION FACILITIES 218.1 General. Transportation facilities shall comply with 218. 218.2 New and Altered Fixed Guideway Stations. New and altered stations in rapid rail, light rail, commuter rail, intercity rail, high speed rail, and other fixed guideway systems shall comply with 810.5 through 810.10. 218.3 Key Stations and Existing Intercity Rail Stations. Key stations and existing intercity rail stations shall comply with 810.5 through 810.10. 218.4 Bus Shelters. Where provided, bus shelters shall comply with 810.3. 218.5 Other Transportation Facilities. In other transportation facilities, public address systems shall comply with 810.7 and clocks shall comply with 810.8. 219 ASSISTIVE LISTENING SYSTEMS 219.1 General. Assistive listening systems shall be provided in accordance with 219 and shall comply with 706. 219.2 Required Systems. In each assembly area where audible communication is integral to the use of the space, an assistive listening system shall be provided. EXCEPTION: Other than in courtrooms, assistive listening systems shall not be required where audio amplification is not provided. 38 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 SCOPING CHAPTER 2: SCOPING REQUIREMENTS 219.3 Receivers. Receivers complying with 706.2 shall be provided for assistive listening systems in each assembly area in accordance with Table 219.3. Twenty-five percent minimum of receivers provided, but no fewer than two, shall be hearing-aid compatible in accordance with 706.3. EXCEPTIONS: 1. Where a building contains more than one assembly area and the assembly areas required to provide assistive listening systems are under one management, the total number of required receivers shall be permitted to be calculated according to the total number of seats in the assembly areas in the building provided that all receivers are usable with all systems. 2. Where all seats in an assembly area are served by an induction loop assistive listening system, the minimum number of receivers required by Table 219.3 to be hearing-aid compatible shall not be required to be provided. TABLE 219.3 RECEIVERS FOR ASSISTIVE LISTENING SYSTEMS Capacity of Seating in Assembly Area Minimum Number of Required Receivers Minimum Number of Required Receivers Required to be Hearing-aid Compatible 50 or less 51 to 200 201 to 500 501 to 1000 1001 to 2000 2001 and over 2 2, plus 1 per 25 seats over 50 seats1 2, plus 1 per 25 seats over 50 seats1 20, plus 1 per 33 seats over 500 seats1 35, plus 1 per 50 seats over 1000 seats1 55 plus 1 per 100 seats over 2000 seats1 2 2 1 per 4 receivers1 1 per 4 receivers1 1 per 4 receivers1 1 per 4 receivers1 1. Or fraction thereof. 220 AUTOMATIC TELLER MACHINES AND FARE MACHINES 220.1 General. Where automatic teller machines or self-service fare vending, collection, or adjustment machines are provided, at least one of each type provided at each location shall comply with 707. Where bins are provided for envelopes, waste paper, or other purposes, at least one of each type shall comply with 811. Advisory 220.1 General. If a bank provides both interior and exterior ATMs, each such installation is considered a separate location. Accessible ATMs, including those with speech and those that are within reach of people who use wheelchairs, must provide all the functions provided to customers at that location at all times. For example, it is unacceptable for the accessible ATM only to provide cash withdrawals while inaccessible ATMs also sell theater tickets. 221 ASSEMBLY AREAS 221.1 General. Assembly areas shall provide wheelchair spaces, companion seats, and designated aisle seats complying with 221 and 802. In addition, lawn seating shall comply with 221.5. 221.1.1 Florida Vertical Accessibility. Nothing in this code relieves the owner of any building, structure, or facility governed by this code from the duty to provide vertical accessibility to all levels above and below the occupiable grade level, regardless of whether the ADA Standards for Accessible Design require an elevator to be installed in such building, structure or facility. EXCEPTION: Theaters, concert halls, and stadiums, or other large assembly areas that have stadium-style seating or tiered seating if the requirements of sections 221 and 802 are met. 221.2 Wheelchair Spaces. Wheelchair spaces complying with 221.2 shall be provided in assembly areas with fixed seating. 221.2.1 Number and Location. Wheelchair spaces shall be provided complying with 221.2.1. 221.2.1.1 General Seating. Wheelchair spaces complying with 802.1 shall be provided in accordance with Table 221.2.1.1. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 39 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 2: SCOPING REQUIREMENTS SCOPING TABLE 221.2.1.1 SEATING CAPACITY Capacity of Seating in Assembly Areas Number of Required Wheelchair Locations 4 to 25 26 to 50 51 to 150 151 to 300 301 to 500 501 to 5000 5001 and over 1 2 4 5 6 6, plus 1 for each 150, or fraction thereof between 501 through 5000 36, plus 1 for each 200, or fraction thereof over 5000 221.2.1.2 Luxury Boxes, Club Boxes, and Suites in Arenas, Stadiums, and Grandstands. In each luxury box, club box, and suite within arenas, stadiums, and grandstands, wheelchair spaces complying with 802.1 shall be provided in accordance with Table 221.2.1.1. Advisory 221.2.1.2 Luxury Boxes, Club Boxes, and Suites in Arenas, Stadiums, and Grandstands. The number of wheelchair spaces required in luxury boxes, club boxes, and suites within an arena, stadium, or grandstand is to be calculated box by box and suite by suite. 221.2.1.3 Other Boxes. In boxes other than those required to comply with 221.2.1.2, the total number of wheelchair spaces required shall be determined in accordance with Table 221.2.1.1. Wheelchair spaces shall be located in not less than 20 percent of all boxes provided. Wheelchair spaces shall comply with 802.1. Advisory 221.2.1.3 Other Boxes. The provision for seating in “other boxes” includes box seating provided in facilities such as performing arts auditoria where tiered boxes are designed for spatial and acoustical purposes. The number of wheelchair spaces required in boxes covered by 221.2.1.3 is calculated based on the total number of seats provided in these other boxes. The resulting number of wheelchair spaces must be located in no fewer than 20% of the boxes covered by this section. For example, a concert hall has 20 boxes, each of which contains 10 seats, totaling 200 seats. In this example, 5 wheelchair spaces would be required, and they must be placed in at least 4 of the boxes. Additionally, because the wheelchair spaces must also meet the dispersion requirements of 221.2.3, the boxes containing these wheelchair spaces cannot all be located in one area unless an exception to the dispersion requirements applies. 221.2.1.4 Team or Player Seating. At least one wheelchair space complying with 802.1 shall be provided in team or player seating areas serving areas of sport activity. EXCEPTION: Wheelchair spaces shall not be required in team or player seating areas serving bowling lanes not required to comply with 206.2.11. 221.2.2 Integration. Wheelchair spaces shall be an integral part of the seating plan. Advisory 221.2.2 Integration. The requirement that wheelchair spaces be an “integral part of the seating plan” means that wheelchair spaces must be placed within the footprint of the seating area. Wheelchair spaces cannot be segregated from seating areas. For example, it would be unacceptable to place only the wheelchair spaces, or only the wheelchair spaces and their associated companion seats, outside the seating areas defined by risers in an assembly area. 221.2.3 Lines of Sight and Dispersion. Wheelchair spaces shall provide lines of sight complying with 802.2 and shall comply with 221.2.3. In providing lines of sight, wheelchair spaces shall be dispersed. Wheelchair spaces shall provide spectators with choices of seating locations and viewing angles that are substantially equivalent to, or better than, the choices of seating locations and viewing angles available to all other spectators. When the number of wheelchair spaces required by 221.2.1 has been met, further dispersion shall not be required. EXCEPTION: Wheelchair spaces in team or player seating areas serving areas of sport activity shall not be required to comply with 221.2.3. 40 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 SCOPING CHAPTER 2: SCOPING REQUIREMENTS Advisory 221.2.3 Lines of Sight and Dispersion. Consistent with the overall intent of the ADA, individuals who use wheelchairs must be provided equal access so that their experience is substantially equivalent to that of other members of the audience. Thus, while individuals who use wheelchairs need not be provided with the best seats in the house, neither may they be relegated to the worst. 221.2.3.1 Horizontal Dispersion. Wheelchair spaces shall be dispersed horizontally. EXCEPTIONS: 1. Horizontal dispersion shall not be required in assembly areas with 300 or fewer seats if the companion seats required by 221.3 and wheelchair spaces are located within the 2nd or 3rd quartile of the total row length. Intermediate aisles shall be included in determining the total row length. If the row length in the 2nd and 3rd quartile of a row is insufficient to accommodate the required number of companion seats and wheelchair spaces, the additional companion seats and wheelchair spaces shall be permitted to be located in the 1st and 4th quartile of the row. 2. In row seating, two wheelchair spaces shall be permitted to be located side-by-side. Advisory 221.2.3.1 Horizontal Dispersion. Horizontal dispersion of wheelchair spaces is the placement of spaces in an assembly facility seating area from side-to-side or, in the case of an arena or stadium, around the field of play or performance area. 221.2.3.2 Vertical Dispersion. Wheelchair spaces shall be dispersed vertically at varying distances from the screen, performance area, or playing field. In addition, wheelchair spaces shall be located in each balcony or mezzanine that is located on an accessible route. EXCEPTIONS: 1. Vertical dispersion shall not be required in assembly areas with 300 or fewer seats if the wheelchair spaces provide viewing angles that are equivalent to, or better than, the average viewing angle provided in the facility. 2. In bleachers, wheelchair spaces shall not be required to be provided in rows other than rows at points of entry to bleacher seating. Advisory 221.2.3.2 Vertical Dispersion. When wheelchair spaces are dispersed vertically in an assembly facility they are placed at different locations within the seating area from front-to-back so that the distance from the screen, stage, playing field, area of sports activity, or other focal point is varied among wheelchair spaces. Advisory 221.2.3.2 Vertical Dispersion Exception 2. Points of entry to bleacher seating may include, but are not limited to, cross aisles, concourses, vomitories, and entrance ramps and stairs. Vertical, center, or side aisles adjoining bleacher seating that are stepped or tiered are not considered entry points. 221.3 Companion Seats. At least one companion seat complying with 802.3 shall be provided for each wheelchair space required by 221.2.1. 221.4 Designated Aisle Seats. At least 5 percent of the total number of aisle seats provided shall comply with 802.4 and shall be the aisle seats located closest to accessible routes. EXCEPTION: Team or player seating areas serving areas of sport activity shall not be required to comply with 221.4. Advisory 221.4 Designated Aisle Seats. When selecting which aisle seats will meet the requirements of 802.4, those aisle seats which are closest to, not necessarily on, accessible routes must be selected first. For example, an assembly area has two aisles (A and B) serving seating areas with an accessible route connecting to the top and bottom of Aisle A only. The aisle seats chosen to meet 802.4 must be those at the top and bottom of Aisle A, working toward the middle. Only when all seats on Aisle A would not meet the five percent minimum would seats on Aisle B be designated. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 41 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 2: SCOPING REQUIREMENTS SCOPING 221.5 Lawn Seating. Lawn seating areas and exterior overflow seating areas, where fixed seats are not provided, shall connect to an accessible route. 221.6 Stadiums, Arenas, and Grandstands. Wheelchair spaces and companion seats shall be dispersed to all levels that include seating served by an accessible route. 221.7 Seating Encircling A Field of Play or Performance. In assembly areas that are required to horizontally disperse wheelchair spaces and companion seats by section 221.2.3.1 and that have seating encircling, in whole or in part, a field of play or performance, wheelchair spaces and companion seats shall be dispersed around that field of play or performance area. 221.8 Temporary Platforms or Other Movable Structures. Wheelchair spaces and companion seats shall not be located on (or obstructed by) temporary platforms or other movable structures, except that when an entire seating section is placed on temporary platforms or other movable structures in an area where fixed seating is not provided, in order to increase seating for an event, wheelchair spaces and companion seats may be placed in that section. When wheelchair spaces and companion seats are not required to accommodate persons eligible for those spaces and seats, individual, removable seats may be placed in those spaces and seats. 221.9 Stadium Style Movie Theaters. Wheelchair spaces and companion seats shall be located on a riser or crossaisle in the stadium section that satisfies at least one of the following criteria: (i) It is located within the rear 60% of the seats provided in an auditorium; or (ii) It is located within the area of an auditorium in which the vertical viewing angles (as measured to the top of the screen) are from the 40th to the 100th percentile of vertical viewing angles for all seats as ranked from the seats in the first row (1st percentile) to seats in the back row (100th percentile). 222 DRESSING, FITTING, AND LOCKER ROOMS 222.1 General. Where dressing rooms, fitting rooms, or locker rooms are provided, at least 5 percent, but no fewer than one, of each type of use in each cluster provided shall comply with 803. Notwithstanding the requirements of this section, section 201.1.1 shall apply. EXCEPTION: In alterations, where it is technically infeasible to provide rooms in accordance with 222.1, one room for each sex on each level shall comply with 803. Where only unisex rooms are provided, unisex rooms shall be permitted. Advisory 222.1 General. A “cluster” is a group of rooms proximate to one another. Generally, rooms in a cluster are within sight of, or adjacent to, one another. Different styles of design provide users varying levels of privacy and convenience. Some designs include private changing facilities that are close to core areas of the facility, while other designs use space more economically and provide only group dressing facilities. Regardless of the type of facility, dressing, fitting, and locker rooms should provide people with disabilities rooms that are equally private and convenient to those provided others. For example, in a physician’s office, if people without disabilities must traverse the full length of the office suite in clothing other than their street clothes, it is acceptable for people with disabilities to be asked to do the same. Florida vertical accessibility requirements of s.553.509, F.S., as incorporated in section 201.1.1 require vertical access to all levels of rooms. Florida requirements may be waived down to the ADA Standards requirements. 222.2 Coat Hooks and Shelves. Where coat hooks or shelves are provided in dressing, fitting or locker rooms without individual compartments, at least one of each type shall comply with 803.5. Where coat hooks or shelves are provided in individual compartments at least one of each type complying with 803.5 shall be provided in individual compartments in dressing, fitting, or locker rooms required to comply with 222.1. 223 MEDICAL CARE AND LONG-TERM CARE FACILITIES 223.1 General. In licensed medical care facilities and licensed long-term care facilities where the period of stay exceeds twenty-four hours, patient or resident sleeping rooms shall be provided in accordance with 223. Notwithstanding the requirements of this section, section 201.1.1 shall apply. EXCEPTION: Toilet rooms that are part of critical or intensive care patient sleeping rooms shall not be required to comply with 603. 42 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 SCOPING CHAPTER 2: SCOPING REQUIREMENTS Advisory 223.1 General. Because medical facilities frequently reconfigure spaces to reflect changes in medical specialties, Section 223.1 does not include a provision for dispersion of accessible patient or resident sleeping rooms. The lack of a design requirement does not mean that covered entities are not required to provide services to people with disabilities where accessible rooms are not dispersed in specialty areas. Locate accessible rooms near core areas that are less likely to change over time. While dispersion is not required, the flexibility it provides can be a critical factor in ensuring cost effective compliance with applicable civil rights laws, including titles II and III of the ADA and Section 504 of the Rehabilitation Act of 1973, as amended. Additionally, all types of features and amenities should be dispersed among accessible sleeping rooms to ensure equal access to and a variety of choices for all patients and residents. Florida vertical accessibility requirements of s.553.509, F.S., as incorporated in section 201.1.1 require vertical access to all levels of facilities. Florida requirements may be waived down to the ADA Standards requirements. 223.1.1 Alterations. Where sleeping rooms are altered or added, the requirements of 223 shall apply only to the sleeping rooms being altered or added until the number of sleeping rooms complies with the minimum number required for new construction. Advisory 223.1.1 Alterations. In alterations and additions, the minimum required number is based on the total number of sleeping rooms altered or added instead of on the total number of sleeping rooms provided in a facility. As a facility is altered over time, every effort should be made to disperse accessible sleeping rooms among patient care areas such as pediatrics, cardiac care, maternity, and other units. In this way, people with disabilities can have access to the full-range of services provided by a medical care facility. 223.2 Hospitals, Rehabilitation Facilities, Psychiatric Facilities and Detoxification Facilities. Hospitals, rehabilitation facilities, psychiatric facilities and detoxification facilities shall comply with 223.2. 223.2.1 Facilities Not Specializing in Treating Conditions That Affect Mobility. In facilities not specializing in treating conditions that affect mobility, at least 10 percent, but no fewer than one, of the patient sleeping rooms shall provide mobility features complying with 805. Accessible patient bedrooms shall be dispersed in a manner that is proportionate by type of medical specialty. 223.2.2 Facilities Specializing in Treating Conditions That Affect Mobility. In facilities specializing in treating conditions that affect mobility, 100 percent of the patient sleeping rooms shall provide mobility features complying with 805. Advisory 223.2.2 Facilities Specializing in Treating Conditions That Affect Mobility. Conditions that affect mobility include conditions requiring the use or assistance of a brace, cane, crutch, prosthetic device, wheelchair, or powered mobility aid; arthritic, neurological, or orthopedic conditions that severely limit one’s ability to walk; respiratory diseases and other conditions which may require the use of portable oxygen; and cardiac conditions that impose significant functional limitations. Facilities that may provide treatment for, but that do not specialize in treatment of such conditions, such as general rehabilitation hospitals, are not subject to this requirement but are subject to Section 223.2.1. 223.3 Long-Term Care Facilities. In licensed long-term care facilities, at least 50 percent, but no fewer than one, of each type of resident sleeping room shall provide mobility features complying with 805. 224 TRANSIENT LODGING GUEST ROOMS 224.1 General. Transient lodging facilities shall provide guest rooms in accordance with 224. Notwithstanding the requirements of this section, section 201.1.1 shall apply. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 43 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 2: SCOPING REQUIREMENTS SCOPING Advisory 224.1 General. Certain facilities used for transient lodging, including time shares, dormitories, and town homes may be covered by both these requirements and the Fair Housing Amendments Act. The Fair Housing Amendments Act requires that certain residential structures having four or more multi-family dwelling units, regardless of whether they are privately owned or federally assisted, include certain features of accessible and adaptable design according to guidelines established by the U.S. Department of Housing and Urban Development (HUD). This law and the appropriate regulations should be consulted before proceeding with the design and construction of residential housing. Florida vertical accessibility requirements of s.553.509, F.S., as incorporated in section 201.1.1 require vertical access to all levels. Florida requirements may be waived down to the ADA Standards requirements. 224.1.1 Alterations. Where guest rooms are altered or added, the requirements of 224 shall apply only to the guest rooms being altered or added until the number of guest rooms complies with the minimum number required for new construction. Advisory 224.1.1 Alterations. In alterations and additions, the minimum required number of accessible guest rooms is based on the total number of guest rooms altered or added instead of the total number of guest rooms provided in a facility. Typically, each alteration of a facility is limited to a particular portion of the facility. When accessible guest rooms are added as a result of subsequent alterations, compliance with 224.5 (Dispersion) is more likely to be achieved if all of the accessible guest rooms are not provided in the same area of the facility. 224.1.2 Guest Room Doors and Doorways. Entrances, doors, and doorways providing user passage into and within guest rooms that are not required to provide mobility features complying with 806.2 shall comply with 404.2.3. EXCEPTION: Shower and sauna doors in guest rooms that are not required to provide mobility features complying with 806.2 shall not be required to comply with 404.2.3. Advisory 224.1.2 Guest Room Doors and Doorways. Because of the social interaction that often occurs in lodging facilities, an accessible clear opening width is required for doors and doorways to and within all guest rooms, including those not required to be accessible. This applies to all doors, including bathroom doors, that allow full user passage. Other requirements for doors and doorways in Section 404 do not apply to guest rooms not required to provide mobility features. 224.2 Guest Rooms with Mobility Features. In transient lodging facilities, guest rooms with mobility features complying with 806.2 shall be provided in accordance with Table 224.2. TABLE 224.2 GUEST ROOMS WITH MOBILITY FEATURES 1 to 25 26 to 50 51 to 75 76 to 100 101 to 150 151 to 200 201 to 300 301 to 400 401 to 500 501 to 1000 1001 and over 44 Minimum Number of Required Rooms Without Roll-in Showers Minimum Number of Required Rooms With Roll-in Showers Total Number of Required Rooms Florida 5% 1 2 3 4 5 6 7 8 9 2 percent of total 20, plus 1 for each 100, or fraction thereof, over 1000 0 0 1 1 2 2 3 4 4 1 percent of total 10, plus 1 for each 100, or fraction thereof, over 1000 1 2 4 5 7 8 10 12 13 3 percent of total 30, plus 2 for each 100, or fraction thereof, over 1000 See Section 224.6.3 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 SCOPING CHAPTER 2: SCOPING REQUIREMENTS 224.3 Beds. In guest rooms having more than 25 beds, 5 percent minimum of the beds shall have clear floor space complying with 806.2.3. 224.4 Guest Rooms with Communication Features. In transient lodging facilities, guest rooms with communication features complying with 806.3 shall be provided in accordance with Table 224.4. TABLE 224.4 GUEST ROOMS WITH COMMUNICATION FEATURES Total Number of Guest Rooms Provided Minimum Number of Required Guest Rooms With Communication Features 2 to 25 26 to 50 51 to 75 76 to 100 101 to 150 151 to 200 201 to 300 301 to 400 401 to 500 501 to 1000 1001 and over 2 4 7 9 12 14 17 20 22 5 percent of total 50, plus 3 for each 100 over 1000 224.5 Dispersion. Guest rooms required to provide mobility features complying with 806.2 and guest rooms required to provide communication features complying with 806.3 shall be dispersed among the various classes of guest rooms, and shall provide choices of types of guest rooms, number of beds, and other amenities comparable to the choices provided to other guests. Where the minimum number of guest rooms required to comply with 806 is not sufficient to allow for complete dispersion, guest rooms shall be dispersed in the following priority: guest room type, number of beds, and amenities. At least one guest room required to provide mobility features complying with 806.2 shall also provide communication features complying with 806.3. Not more than 10 percent of guest rooms required to provide mobility features complying with 806.2 shall be used to satisfy the minimum number of guest rooms required to provide communication features complying with 806.3. Advisory 224.5 Dispersion. Factors to be considered in providing an equivalent range of options may include, but are not limited to, room size, bed size, cost, view, bathroom fixtures such as hot tubs and spas, smoking and nonsmoking, and the number of rooms provided. 224.6 Places of Lodging. Places of lodging shall comply with the requirements for transient lodging guest rooms in sections 224 and 806. EXCEPTION: Alterations to guest rooms in places of lodging where the guest rooms are not owned or substantially controlled by the entity that owns, leases, or operates the overall facility and the physical features of the guest room interiors are controlled by their individual owners are not required to comply with § 36.402 or the alterations requirements in section 224.1.1 of the 2010 Standards. 224.6.1 Guest rooms. Guest rooms with mobility features shall be provided as follows: (i) Facilities that are subject to the same permit application on a common site that each have 50 or fewer guest rooms may be combined for the purposes of determining the required number of accessible rooms and type of accessible bathing facility in accordance with table 224.2; (ii) Facilities with more than 50 guest rooms shall be treated separately for the purposes of determining the required number of accessible rooms and type of accessible bathing facility in accordance with table 224.2. 224.6.2 Facilities With Residential Units and Transient Lodging Units. Residential dwelling units that are designed and constructed for residential use exclusively are not subject to the transient lodging standards. 224.6.3 Buildings, Structures, or Facilities Licensed as a Hotel, Motel, or Condominium Pursuant to Chapter 509, F.S. All buildings, structures, or facilities licensed as a hotel, motel, or condominium pursuant to chapter 509, F.S., a number of rooms equaling at least 5 percent of the guest rooms minus the Total Number of Required (accessible) Rooms required by Table 224.2 shall provide special accessibility features of 806.4. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 45 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 2: SCOPING REQUIREMENTS SCOPING 224.7 Housing at a place of education. Housing at a place of education shall comply with the requirements for transient lodging guest rooms in sections 224 and 806, subject to the following exceptions. The term “sleeping room” is intended to be used interchangeably with the term “guest room” as it is used in the transient lodging standards. EXCEPTIONS: 1. Kitchens within housing units containing accessible sleeping rooms with mobility features (including suites and clustered sleeping rooms) or on floors containing accessible sleeping rooms with mobility features shall provide turning spaces that comply with section 809.2.2 and kitchen work surfaces that comply with section 804.3. 2. Multi-bedroom housing units containing accessible sleeping rooms with mobility features shall have an accessible route throughout the unit in accordance with section 809.2. 3. Apartments or townhouse facilities that are provided by or on behalf of a place of education, which are leased on a year-round basis exclusively to graduate students or faculty and do not contain any public use or common use areas available for educational programming, are not subject to the transient lodging standards and shall comply with the requirements for residential facilities in sections 233 and 809. 225 STORAGE 225.1 General. Storage facilities shall comply with 225. 225.2 Storage. Where storage is provided in accessible spaces, at least one of each type shall comply with 811. Advisory 225.2 Storage. Types of storage include, but are not limited to, closets, cabinets, shelves, clothes rods, hooks, and drawers. Where provided, at least one of each type of storage must be within the reach ranges specified in 308; however, it is permissible to install additional storage outside the reach ranges. 225.2.1 Lockers. Where lockers are provided, at least 5 percent, but no fewer than one of each type, shall comply with 811. Advisory 225.2.1 Lockers. Different types of lockers may include full-size and half-size lockers, as well as those specifically designed for storage of various sports equipment. 225.2.2 Self-Service Shelving. Self-service shelves shall be located on an accessible route complying with 402. Self-service shelving shall not be required to comply with 308. Advisory 225.2.2 Self-Service Shelving. Self-service shelves include, but are not limited to, library, store, or post office shelves. 225.3 Self-Service Storage Facilities. Self-service storage facilities shall provide individual self-service storage spaces complying with these requirements in accordance with Table 225.3. Advisory 225.3 Self-Service Storage Facilities. Although there are no technical requirements that are unique to self-service storage facilities, elements and spaces provided in facilities containing self-service storage spaces required to comply with these requirements must comply with this code where applicable. For example: the number of storage spaces required to comply with these requirements must provide accessible Routes complying with Section 206; Accessible Means of Egress complying with Section 207; Parking Spaces complying with Section 208; and, where provided, other public use or common use elements and facilities such as toilet rooms, drinking fountains, and telephones must comply with the applicable requirements of this code. TABLE 225.3 SELF-SERVICE STORAGE FACILITIES Total Spaces in Facility Minimum Number of Spaces Required to be Accessible 1 to 200 201 and over 5 percent, but no fewer than 1 10, plus 2 percent of total number of units over 200 225.3.1 Dispersion. Individual self-service storage spaces shall be dispersed throughout the various classes of spaces provided. Where more classes of spaces are provided than the number required to be accessible, the 46 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 SCOPING CHAPTER 2: SCOPING REQUIREMENTS number of spaces shall not be required to exceed that required by Table 225.3. Self-service storage spaces complying with Table 225.3 shall not be required to be dispersed among buildings in a multi-building facility. 226 DINING SURFACES AND WORK SURFACES 226.1 General. Where dining surfaces are provided for the consumption of food or drink, at least 5 percent of the seating spaces and standing spaces at the dining surfaces shall comply with 902. In addition, where work surfaces are provided for use by other than employees, at least 5 percent shall comply with 902. EXCEPTIONS: 1. Sales counters and service counters shall not be required to comply with 902. 2. Check writing surfaces provided at check-out aisles not required to comply with 904.3 shall not be required to comply with 902. Advisory 226.1 General. In facilities covered by the ADA, this requirement does not apply to work surfaces used only by employees. However, the ADA and, where applicable, Section 504 of the Rehabilitation Act of 1973, as amended, provide that employees are entitled to “reasonable accommodations.” With respect to work surfaces, this means that employers may need to procure or adjust work stations such as desks, laboratory and work benches, fume hoods, reception counters, teller windows, study carrels, commercial kitchen counters, and conference tables to accommodate the individual needs of employees with disabilities on an “as needed” basis. Consider work surfaces that are flexible and permit installation at variable heights and clearances. 226.2 Dispersion. Dining surfaces and work surfaces required to comply with 902 shall be dispersed throughout the space or facility containing dining surfaces and work surfaces. 227 SALES AND SERVICE 227.1 General. Where provided, check-out aisles, sales counters, service counters, food service lines, queues, and waiting lines shall comply with 227 and 904. Notwithstanding the requirements of this section, section 201.1.1 shall apply. 227.2 Check-Out Aisles. Where check-out aisles are provided, check-out aisles complying with 904.3 shall be provided in accordance with Table 227.2. Where check-out aisles serve different functions, check-out aisles complying with 904.3 shall be provided in accordance with Table 227.2 for each function. Where check-out aisles are dispersed throughout the building or facility, check-out aisles complying with 904.3 shall be dispersed. EXCEPTION: Where the selling space is under 5000 square feet (465 m2) no more than one check-out aisle complying with 904.3 shall be required. TABLE 227.2 CHECK-OUT AISLES Number of Check-Out Aisles of Each Function Minimum Number of Check-Out Aisles of Each Function Required to Comply with 904.3 1 to 4 5 to 8 9 to 15 16 and over 1 2 3 3, plus 20 percent of additional aisles 227.2.1 Altered Check-Out Aisles. Where check-out aisles are altered, at least one of each check-out aisle serving each function shall comply with 904.3 until the number of check-out aisles complies with 227.2. 227.3 Counters. Where provided, at least one of each type of sales counter and service counter shall comply with 904.4. Where counters are dispersed throughout the building or facility, counters complying with 904.4 also shall be dispersed. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 47 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 2: SCOPING REQUIREMENTS SCOPING Advisory 227.3 Counters. Types of counters that provide different services in the same facility include, but are not limited to, order, pick-up, express, and returns. One continuous counter can be used to provide different types of service. For example, order and pick-up are different services. It would not be acceptable to provide access only to the part of the counter where orders are taken when orders are picked-up at a different location on the same counter. Both the order and pick-up section of the counter must be accessible. 227.4 Food Service Lines. Food service lines shall comply with 904.5. Where self-service shelves are provided, at least 50 percent, but no fewer than one, of each type provided shall comply with 308. 227.5 Queues and Waiting Lines. Queues and waiting lines servicing counters or check-out aisles required to comply with 904.3 or 904.4 shall comply with 403. 228 DEPOSITORIES, VENDING MACHINES, CHANGE MACHINES, MAIL BOXES, AND FUEL DISPENSERS 228.1 General. Where provided, at least one of each type of depository, vending machine, change machine, and fuel dispenser shall comply with 309. EXCEPTION: Drive-up only depositories shall not be required to comply with 309. Advisory 228.1 General. Depositories include, but are not limited to, night receptacles in banks, post offices, video stores, and libraries. 228.2 Mail Boxes. Where mail boxes are provided in an interior location, at least 5 percent, but no fewer than one, of each type shall comply with 309. In residential facilities, where mail boxes are provided for each residential dwelling unit, mail boxes complying with 309 shall be provided for each residential dwelling unit required to provide mobility features complying with 809.2 through 809.4. 229 WINDOWS 229.1 General. Where glazed openings are provided in accessible rooms or spaces for operation by occupants, at least one opening shall comply with 309. Each glazed opening required by an administrative authority to be operable shall comply with 309. EXCEPTION: 1. Glazed openings in residential dwelling units required to comply with 809 shall not be required to comply with 229. 2. Glazed openings in guest rooms required to provide communication features and in guest rooms required to comply with 206.5.3 shall not be required to comply with 229. 230 TWO-WAY COMMUNICATION SYSTEMS 230.1 General. Where a two-way communication system is provided to gain admittance to a building or facility or to restricted areas within a building or facility, the system shall comply with 708. Advisory 230.1 General. This requirement applies to facilities such as office buildings, courthouses, and other facilities where admittance to the building or restricted spaces is dependent on two-way communication systems. 231 JUDICIAL FACILITIES 231.1 General. Judicial facilities shall comply with 231. Notwithstanding the requirements of this section, section 201.1.1 shall apply. 48 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 SCOPING CHAPTER 2: SCOPING REQUIREMENTS 231.2 Courtrooms. Each courtroom shall comply with 808. 231.3 Holding Cells. Where provided, central holding cells and court-floor holding cells shall comply with 231.3. 231.3.1 Central Holding Cells. Where separate central holding cells are provided for adult male, juvenile male, adult female, or juvenile female, one of each type shall comply with 807.2. Where central holding cells are provided and are not separated by age or sex, at least one cell complying with 807.2 shall be provided. 231.3.2 Court-Floor Holding Cells. Where separate court-floor holding cells are provided for adult male, juvenile male, adult female, or juvenile female, each courtroom shall be served by one cell of each type complying with 807.2. Where court-floor holding cells are provided and are not separated by age or sex, courtrooms shall be served by at least one cell complying with 807.2. Cells may serve more than one courtroom. 231.4 Visiting Areas. Visiting areas shall comply with 231.4. 231.4.1 Cubicles and Counters. At least 5 percent, but no fewer than one, of cubicles shall comply with 902 on both the visitor and detainee sides. Where counters are provided, at least one shall comply with 904.4.2 on both the visitor and detainee sides. EXCEPTION: The detainee side of cubicles or counters at non-contact visiting areas not serving holding cells required to comply with 231 shall not be required to comply with 902 or 904.4.2. 231.4.2 Partitions. Where solid partitions or security glazing separate visitors from detainees at least one of each type of cubicle or counter partition shall comply with 904.6. 232 DETENTION FACILITIES AND CORRECTIONAL FACILITIES 232.1 General. Buildings, facilities, or portions thereof, in which people are detained for penal or correction purposes, or in which the liberty of the inmates is restricted for security reasons shall comply with 232. Notwithstanding the requirements of this section, section 201.1.1 shall apply. Advisory 232.1 General. Detention facilities include, but are not limited to, jails, detention centers, and holding cells in police stations. Correctional facilities include, but are not limited to, prisons, reformatories, and correctional centers. Florida vertical accessibility requirements of s.553.509, F.S., as incorporated in section 201.1.1 require vertical access to all levels of facilities. Florida requirements may be waived down to the ADA Standards requirements. 232.2 General Holding Cells and General Housing Cells. General holding cells and general housing cells shall be provided in accordance with 232.2. EXCEPTION: Alterations to cells shall not be required to comply except to the extent determined by 232.2.1 Exception 2. Advisory 232.2 General Holding Cells and General Housing Cells. Accessible cells or rooms should be dispersed among different levels of security, housing categories, and holding classifications (e.g., male/female and adult/juvenile) to facilitate access. Many detention and correctional facilities are designed so that certain areas (e.g., “shift” areas) can be adapted to serve as different types of housing according to need. For example, a shift area serving as a medium-security housing unit might be redesignated for a period of time as a high-security housing unit to meet capacity needs. Placement of accessible cells or rooms in shift areas may allow additional flexibility in meeting requirements for dispersion of accessible cells or rooms. Advisory 232.2 General Holding Cells and General Housing Cells Exception. Although these requirements do not specify that cells be accessible as a consequence of an alteration, title II of the ADA requires that each service, program, or activity conducted by a public entity, when viewed in its entirety, be readily accessible to and usable by individuals with disabilities. This requirement must be met unless doing so would fundamentally alter the nature of a service, program, or activity or would result in undue financial and administrative burdens. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 49 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 2: SCOPING REQUIREMENTS SCOPING 232.2.1 Cells with Mobility Features. At least 2 percent, but no fewer than one, of the total number of cells in a facility shall provide mobility features complying with 807.2. EXCEPTIONS: 1. New construction of jails, prisons, and other detention and correctional facilities by public entities shall provide accessible mobility features complying with section 807.2 for a minimum of 3%, but no fewer than one, of the total number of cells in a facility. Cells with mobility features shall be provided in each classification level. 2. Alterations to detention and correctional facilities. Alterations to jails, prisons, and other detention and correctional facilities by public entities shall provide accessible mobility features complying with section 807.2 for a minimum of 3 percent, but no fewer than one, of the total number of cells being altered until at least 3 percent, but no fewer than one, of the total number of cells in a facility shall provide mobility features complying with section 807.2. Altered cells with mobility features shall be provided in each classification level. However, when alterations are made to specific cells, detention and correctional facility operators may satisfy their obligation to provide the required number of cells with mobility features by providing the required mobility features in substitute cells (cells other than those where alterations are originally planned), provided that each substitute cell: (i) is located within the same prison site; (ii) Is integrated with other cells to the maximum extent feasible; (iii) Has, at a minimum, equal physical access as the altered cells to areas used by inmates or detainees for visitation, dining, recreation, educational programs, medical services, work programs, religious services, and participation in other programs that the facility offers to inmates or detainees; and, (iv) If it is technically infeasible to locate a substitute cell within the same prison site, a substitute cell must be provided at another prison site within the corrections system. 232.2.1.1 Beds. In cells having more than 25 beds, at least 5 percent of the beds shall have clear floor space complying with 807.2.3. 232.2.2 Cells with Communication Features. At least 2 percent, but no fewer than one, of the total number of general holding cells and general housing cells equipped with audible emergency alarm systems and permanently installed telephones within the cell shall provide communication features complying with 807.3. 232.3 Special Holding Cells and Special Housing Cells. Where special holding cells or special housing cells are provided, at least one cell serving each purpose shall provide mobility features complying with 807.2. Cells subject to this requirement include, but are not limited to, those used for purposes of orientation, protective custody, administrative or disciplinary detention or segregation, detoxification, and medical isolation. EXCEPTION: Alterations to cells shall not be required to comply except to the extent determined by the Attorney General. 232.4 Medical Care Facilities. Patient bedrooms or cells required to comply with 223 shall be provided in addition to any medical isolation cells required to comply with 232.3. 232.4.1 Medical and Long-Term Care Facilities in Jails, Prisons, and Other Detention and Correctional Facilities. Public entities shall comply with 223 irrespective of whether those facilities are licensed. 232.5 Visiting Areas. Visiting areas shall comply with 232.5. 232.5.1 Cubicles and Counters. At least 5 percent, but no fewer than one, of cubicles shall comply with 902 on both the visitor and detainee sides. Where counters are provided, at least one shall comply with 904.4.2 on both the visitor and detainee or inmate sides. EXCEPTION: The inmate or detainee side of cubicles or counters at non-contact visiting areas not serving holding cells or housing cells required to comply with 232 shall not be required to comply with 902 or 904.4.2. 232.5.2 Partitions. Where solid partitions or security glazing separate visitors from detainees or inmates at least one of each type of cubicle or counter partition shall comply with 904.6. 233 RESIDENTIAL FACILITIES 233.1 General. Facilities with residential dwelling units shall comply with 233. Notwithstanding the requirements of this section, section 201.1.1 shall apply. 50 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 SCOPING CHAPTER 2: SCOPING REQUIREMENTS Advisory 233.1 General. Section 233 outlines the requirements for residential facilities subject to the Americans with Disabilities Act of 1990. The facilities covered by Section 233, as well as other facilities not covered by this section, may still be subject to other Federal laws such as the Fair Housing Act and Section 504 of the Rehabilitation Act of 1973, as amended. For example, the Fair Housing Act requires that certain residential structures having four or more multi-family dwelling units, regardless of whether they are privately owned or federally assisted, include certain features of accessible and adaptable design according to guidelines established by the U.S. Department of Housing and Urban Development (HUD). These laws and the appropriate regulations should be consulted before proceeding with the design and construction of residential facilities. Florida law s.553.504(2), F.S., incorporated in section 233.3.6 establishes bathroom requirements for all new single-family houses, duplexes, triplexes, condominiums, and townhouses. Residential facilities containing residential dwelling units provided by entities subject to HUD’s Section 504 regulations and residential dwelling units covered by Section 233.3 must comply with the technical and scoping requirements in Chapters 1 through 10 included in this code. Section 233 is not a stand-alone section; this section only addresses the minimum number of residential dwelling units within a facility required to comply with Chapter 8. However, residential facilities must also comply with the requirements of this code. For example: Section 206.5.4 requires all doors and doorways providing user passage in residential dwelling units providing mobility features to comply with Section 404; Section 206.7.6 permits platform lifts to be used to connect levels within residential dwelling units providing mobility features; Section 208 provides general scoping for accessible parking and Section 208.2.3.1 specifies the required number of accessible parking spaces for each residential dwelling unit providing mobility features; Section 228.2 requires mail boxes to be within reach ranges when they serve residential dwelling units providing mobility features; play areas are addressed in Section 240; and swimming pools are addressed in Section 242. There are special provisions applicable to facilities containing residential dwelling units at: Exception 3 to 202.3; Exception to 202.4; 203.8; and Exception 4 to 206.2.3. Florida vertical accessibility requirements of s.553.509, F.S., as incorporated in section 201.1.1 require vertical access to all levels for accessible units. Florida requirements may be waived down to the ADA Standards requirements. 233.2 Residential Dwelling Units Provided by Entities Subject to HUD Section 504 Regulations. Where facilities with residential dwelling units are provided by entities subject to regulations issued by the Department of Housing and Urban Development (HUD) under Section 504 of the Rehabilitation Act of 1973, as amended, such entities shall provide residential dwelling units with mobility features complying with 809.2 through 809.4 in a number required by the applicable HUD regulations. Residential dwelling units required to provide mobility features complying with 809.2 through 809.4 shall be on an accessible route as required by 206. In addition, such entities shall provide residential dwelling units with communication features complying with 809.5 in a number required by the applicable HUD regulations. Entities subject to 233.2 shall not be required to comply with 233.3. Advisory 233.2 Residential Dwelling Units Provided by Entities Subject to HUD Section 504 Regulations. Section 233.2 requires that entities subject to HUD’s regulations implementing Section 504 of the Rehabilitation Act of 1973, as amended, provide residential dwelling units containing mobility features and residential dwelling units containing communication features complying with these regulations in a number specified in HUD’s Section 504 regulations. Further, the residential dwelling units provided must be dispersed according to HUD’s Section 504 criteria. In addition, Section 233.2 defers to HUD the specification of criteria by which the technical requirements of this code will apply to alterations of existing facilities subject to HUD’s Section 504 regulations. 233.3 Residential Dwelling Units Provided by Entities Not Subject to HUD Section 504 Regulations. Facilities with residential dwelling units provided by entities not subject to regulations issued by the Department of Housing and Urban Development (HUD) under Section 504 of the Rehabilitation Act of 1973, as amended, shall comply with 233.3. 233.3.1 Minimum Number: New Construction. Newly constructed facilities with residential dwelling units shall comply with 233.3.1. EXCEPTION: Where facilities contain 15 or fewer residential dwelling units, the requirements of 233.3.1.1 and 233.3.1.2 shall apply to the total number of residential dwelling units that are constructed under a single contract, or are developed as a whole, whether or not located on a common site. 233.3.1.1 Residential Dwelling Units with Mobility Features. In facilities with residential dwelling units, at least 5 percent, but no fewer than one unit, of the total number of residential dwelling units shall provide mobility features complying with 809.2 through 809.4 and shall be on an accessible route as required by 206. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 51 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 2: SCOPING REQUIREMENTS SCOPING 233.3.1.2 Residential Dwelling Units with Communication Features. In facilities with residential dwelling units, at least 2 percent, but no fewer than one unit, of the total number of residential dwelling units shall provide communication features complying with 809.5. 233.3.2 Residential Dwelling Units for Sale. Residential dwelling units offered for sale shall provide accessible features to the extent required by regulations issued for Section 504 of the Rehabilitation Act of 1973, as amended. Residential dwelling units designed and constructed or altered by public entities that will be offered for sale to individuals shall comply with the requirements for residential facilities in sections 233 and 809. Advisory 233.3.2 Residential Dwelling for Sale. DOJ regulation 28 CFR 35.1511(j)(2), for public entities (Title II) adds the following clarification regarding construction of dwelling units for sale to preselected buyers with disabilities: “The requirements of paragraph (1) also apply to housing programs that are operated by public entities where design and construction of particular residential dwelling units take place only after a specific buyer has been identified. In such programs, the covered entity must provide the units that comply with the requirements for accessible features to those pre-identified buyers with disabilities who have requested such a unit.” 233.3.3 Additions. Where an addition to an existing building results in an increase in the number of residential dwelling units, the requirements of 233.3.1 shall apply only to the residential dwelling units that are added until the total number of residential dwelling units complies with the minimum number required by 233.3.1. Residential dwelling units required to comply with 233.3.1.1 shall be on an accessible route as required by 206. 233.3.4 Alterations. Alterations shall comply with 233.3.4. EXCEPTION: Where compliance with 809.2, 809.3, or 809.4 is technically infeasible, or where it is technically infeasible to provide an accessible route to a residential dwelling unit, the entity shall be permitted to alter or construct a comparable residential dwelling unit to comply with 809.2 through 809.4 provided that the minimum number of residential dwelling units required by 233.3.1.1 and 233.3.1.2, as applicable, is satisfied. Advisory 233.3.4 Alterations Exception. A substituted dwelling unit must be comparable to the dwelling unit that is not made accessible. Factors to be considered in comparing one dwelling unit to another should include the number of bedrooms; amenities provided within the dwelling unit; types of common spaces provided within the facility; and location with respect to community resources and services, such as public transportation and civic, recreational, and mercantile facilities. 233.3.4.1 Alterations to Vacated Buildings. Where a building is vacated for the purposes of alteration, and the altered building contains more than 15 residential dwelling units, at least 5 percent of the residential dwelling units shall comply with 809.2 through 809.4 and shall be on an accessible route as required by 206. In addition, at least 2 percent of the residential dwelling units shall comply with 809.5. Advisory 233.3.4.1 Alterations to Vacated Buildings. This provision is intended to apply where a building is vacated with the intent to alter the building. Buildings that are vacated solely for pest control or asbestos removal are not subject to the requirements to provide residential dwelling units with mobility features or communication features. 233.3.4.2 Alterations to Individual Residential Dwelling Units. In individual residential dwelling units, where a bathroom or a kitchen is substantially altered, and at least one other room is altered, the requirements of 233.3.1 shall apply to the altered residential dwelling units until the total number of residential dwelling units complies with the minimum number required by 233.3.1.1 and 233.3.1.2. Residential dwelling units required to comply with 233.3.1.1 shall be on an accessible route as required by 206. EXCEPTION: Where facilities contain 15 or fewer residential dwelling units, the requirements of 233.3.1.1 and 233.3.1.2 shall apply to the total number of residential dwelling units that are altered under a single contract, or are developed as a whole, whether or not located on a common site. 52 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 SCOPING CHAPTER 2: SCOPING REQUIREMENTS Advisory 233.3.4.2 Alterations to Individual Residential Dwelling Units. Section 233.3.4.2 uses the terms “substantially altered” and “altered.” A substantial alteration to a kitchen or bathroom includes, but is not limited to, alterations that are changes to or rearrangements in the plan configuration, or replacement of cabinetry. Substantial alterations do not include normal maintenance or appliance and fixture replacement, unless such maintenance or replacement requires changes to or rearrangements in the plan configuration, or replacement of cabinetry. The term “alteration” is defined both in Section 106 of these requirements and in the Department of Justice ADA regulations. 233.3.5 Dispersion. Residential dwelling units required to provide mobility features complying with 809.2 through 809.4 and residential dwelling units required to provide communication features complying with 809.5 shall be dispersed among the various types of residential dwelling units in the facility and shall provide choices of residential dwelling units comparable to, and integrated with, those available to other residents. EXCEPTION: Where multi-story residential dwelling units are one of the types of residential dwelling units provided, one-story residential dwelling units shall be permitted as a substitute for multi-story residential dwelling units where equivalent spaces and amenities are provided in the one-story residential dwelling unit. 233.3.6 All new single-family houses, duplexes, triplexes, condominiums, and townhouses shall provide at least one bathroom, located with maximum possible privacy, where bathrooms are provided on habitable grade levels, with a door that has a 29-inch clear opening. However, if only a toilet room is provided at grade level, such toilet room shall have a clear opening of at least 29 inches. 233.4 Social Service Center Establishments. Group homes, halfway houses, shelters, or similar social service center establishments that provide either temporary sleeping accommodations or residential dwelling units shall comply with the provisions applicable to residential facilities in sections 233 and 809. 233.4.1 In sleeping rooms with more than 25 beds, a minimum of 5 percent of the beds shall have clear floor space complying with section 806.2.3. 233.4.2 Facilities with more than 50 beds covered that provide common use bathing facilities shall provide at least one roll-in shower with a seat that complies with section 608. Transfer-type showers are not permitted in lieu of a roll-in shower with a seat, and the exceptions in sections 608.3 and 608.4 for residential dwelling units are not permitted. When separate shower facilities are provided for men and for women, at least one roll-in shower shall be provided for each group. 233.5 Apartments or Townhouse Facilities Provided By or on Behalf of A Place of Education. Apartments or townhouse facilities that are provided by or on behalf of a place of education, which are leased on a year-round basis exclusively to graduate students or faculty and do not contain any public use or common use areas available for educational programming shall comply with the requirements for residential facilities in sections 233 and 809. 233.6 Residential Dwelling Units Designed and Constructed or Altered by Public Entities that will be Offered for Sale to Individuals. Residential dwelling units designed and constructed or altered by public entities that will be offered for sale to individuals shall comply with the requirements for residential facilities in sections 233 and 809. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 53 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 2: SCOPING REQUIREMENTS SCOPING 234 AMUSEMENT RIDES 234.1 General. Amusement rides shall comply with 234. EXCEPTION: Mobile or portable amusement rides shall not be required to comply with 234. Advisory 234.1 General. These requirements apply generally to newly designed and constructed amusement rides and attractions. A custom designed and constructed ride is new upon its first use, which is the first time amusement park patrons take the ride. With respect to amusement rides purchased from other entities, new refers to the first permanent installation of the ride, whether it is used off the shelf or modified before it is installed. Where amusement rides are moved after several seasons to another area of the park or to another park, the ride would not be considered newly designed or newly constructed. Some amusement rides and attractions that have unique designs and features are not addressed by these requirements. In those situations, these requirements are to be applied to the extent possible. An example of an amusement ride not specifically addressed by these requirements includes “virtual reality” rides where the device does not move through a fixed course within a defined area. An accessible route must be provided to these rides. Where an attraction or ride has unique features for which there are no applicable scoping provisions, then a reasonable number, but at least one, of the features must be located on an accessible route. Where there are appropriate technical provisions, they must be applied to the elements that are covered by the scoping provisions. Advisory 234.1 General Exception. Mobile or temporary rides are those set up for short periods of time such as traveling carnivals, State and county fairs, and festivals. The amusement rides that are covered by 234.1 are ones that are not regularly assembled and disassembled. 234.2 Load and Unload Areas. Load and unload areas serving amusement rides shall comply with 1002.3. 234.3 Minimum Number. Amusement rides shall provide at least one wheelchair space complying with 1002.4, or at least one amusement ride seat designed for transfer complying with 1002.5, or at least one transfer device complying with 1002.6. EXCEPTIONS: 1. Amusement rides that are controlled or operated by the rider shall not be required to comply with 234.3. 2. Amusement rides designed primarily for children, where children are assisted on and off the ride by an adult, shall not be required to comply with 234.3. 3. Amusement rides that do not provide amusement ride seats shall not be required to comply with 234.3. Advisory 234.3 Minimum Number Exceptions 1 through 3. Amusement rides controlled or operated by the rider, designed for children, or rides without ride seats are not required to comply with 234.3. These rides are not exempt from the other provisions in 234 requiring an accessible route to the load and unload areas and to the ride. The exception does not apply to those rides where patrons may cause the ride to make incidental movements, but where the patron otherwise has no control over the ride. Advisory 234.3 Minimum Number Exception 2. The exception is limited to those rides designed “primarily” for children, where children are assisted on and off the ride by an adult. This exception is limited to those rides designed for children and not for the occasional adult user. An accessible route to and turning space in the load and unload area will provide access for adults and family members assisting children on and off these rides. 234.4 Existing Amusement Rides. Where existing amusement rides are altered, the alteration shall comply with 234.4. Advisory 234.4 Existing Amusement Rides. Routine maintenance, painting, and changing of theme boards are examples of activities that do not constitute an alteration subject to this section. 234.4.1 Load and Unload Areas. Where load and unload areas serving existing amusement rides are newly designed and constructed, the load and unload areas shall comply with 1002.3. 234.4.2 Minimum Number. Where the structural or operational characteristics of an amusement ride are altered 54 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 SCOPING CHAPTER 2: SCOPING REQUIREMENTS to the extent that the amusement ride’s performance differs from that specified by the manufacturer or the original design, the amusement ride shall comply with 234.3. 235 RECREATIONAL BOATING FACILITIES 235.1 General. Recreational boating facilities shall comply with 235. 235.2 Boat Slips. Boat slips complying with 1003.3.1 shall be provided in accordance with Table 235.2. Where the number of boat slips is not identified, each 40 feet (12 m) of boat slip edge provided along the perimeter of the pier shall be counted as one boat slip for the purpose of this section. TABLE 235.2 BOAT SLIPS Total Number of Boat Slips Provided in Facility Minimum Number of Required Accessible Boat Slips 1 to 25 26 to 50 51 to 100 101 to 150 151 to 300 301 to 400 401 to 500 501 to 600 601 to 700 701 to 800 801 to 900 901 to 1000 1 2 3 4 5 6 7 8 9 10 11 12 12, plus 1 for every 100, or fraction thereof, over 1000 1001 and over Advisory 235.2 Boat Slips. The requirement for boat slips also applies to piers where boat slips are not demarcated. For example, a single pier 25 feet (7620 mm) long and 5 feet (1525 mm) wide (the minimum width specified by Section 1003.3) allows boats to moor on three sides. Because the number of boat slips is not demarcated, the total length of boat slip edge (55 feet, 17 m) must be used to determine the number of boat slips provided (two). This number is based on the specification in Section 235.2 that each 40 feet (12 m) of boat slip edge, or fraction thereof, counts as one boat slip. In this example, Table 235.2 would require one boat slip to be accessible. 235.2.1 Dispersion. Boat slips complying with 1003.3.1 shall be dispersed throughout the various types of boat slips provided. Where the minimum number of boat slips required to comply with 1003.3.1 has been met, no further dispersion shall be required. Advisory 235.2.1 Dispersion. Types of boat slips are based on the size of the boat slips; whether single berths or double berths, shallow water or deep water, transient or longer-term lease, covered or uncovered; and whether slips are equipped with features such as telephone, water, electricity or cable connections. The term “boat slip” is intended to cover any pier area other than launch ramp boarding piers where recreational boats are moored for purposes of berthing, embarking, or disembarking. For example, a fuel pier may contain boat slips, and this type of short term slip would be included in determining compliance with 235.2. 235.3 Boarding Piers at Boat Launch Ramps. Where boarding piers are provided at boat launch ramps, at least 5 percent, but no fewer than one, of the boarding piers shall comply with 1003.3.2. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 55 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 2: SCOPING REQUIREMENTS SCOPING 236 EXERCISE MACHINES AND EQUIPMENT 236.1 General. At least one of each type of exercise machine and equipment shall comply with 1004. Advisory 236.1 General. Most strength training equipment and machines are considered different types. Where operators provide a biceps curl machine and cable-cross-over machine, both machines are required to meet the provisions in this section, even though an individual may be able to work on their biceps through both types of equipment. Similarly, there are many types of cardiovascular exercise machines, such as stationary bicycles, rowing machines, stair climbers, and treadmills. Each machine provides a cardiovascular exercise and is considered a different type for purposes of these requirements. 237 FISHING PIERS AND PLATFORMS 237.1 General. Fishing piers and platforms shall comply with 1005. 238 GOLF FACILITIES 238.1 General. Golf facilities shall comply with 238. 238.2 Golf Courses. Golf courses shall comply with 238.2. 238.2.1 Teeing Grounds. Where one teeing ground is provided for a hole, the teeing ground shall be designed and constructed so that a golf car can enter and exit the teeing ground. Where two teeing grounds are provided for a hole, the forward teeing ground shall be designed and constructed so that a golf car can enter and exit the teeing ground. Where three or more teeing grounds are provided for a hole, at least two teeing grounds, including the forward teeing ground, shall be designed and constructed so that a golf car can enter and exit each teeing ground. EXCEPTION: In existing golf courses, the forward teeing ground shall not be required to be one of the teeing grounds on a hole designed and constructed so that a golf car can enter and exit the teeing ground where compliance is not feasible due to terrain. 238.2.2 Putting Greens. Putting greens shall be designed and constructed so that a golf car can enter and exit the putting green. 238.2.3 Weather Shelters. Where provided, weather shelters shall be designed and constructed so that a golf car can enter and exit the weather shelter and shall comply with 1006.4. 238.3 Practice Putting Greens, Practice Teeing Grounds, and Teeing Stations at Driving Ranges. At least 5 percent, but no fewer than one, of practice putting greens, practice teeing grounds, and teeing stations at driving ranges shall be designed and constructed so that a golf car can enter and exit the practice putting greens, practice teeing grounds, and teeing stations at driving ranges. 239 MINIATURE GOLF FACILITIES 239.1 General. Miniature golf facilities shall comply with 239. 239.2 Minimum Number. At least 50 percent of holes on miniature golf courses shall comply with 1007.3. Advisory 239.2 Minimum Number. Where possible, providing access to all holes on a miniature golf course is recommended. If a course is designed with the minimum 50 percent accessible holes, designers or operators are encouraged to select holes which provide for an equivalent experience to the maximum extent possible. 56 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 SCOPING CHAPTER 2: SCOPING REQUIREMENTS 239.3 Miniature Golf Course Configuration. Miniature golf courses shall be configured so that the holes complying with 1007.3 are consecutive. Miniature golf courses shall provide an accessible route from the last hole complying with 1007.3 to the course entrance or exit without requiring travel through any other holes on the course. EXCEPTION: One break in the sequence of consecutive holes shall be permitted provided that the last hole on the miniature golf course is the last hole in the sequence. Advisory 239.3 Miniature Golf Course Configuration. Where only the minimum 50 percent of the holes are accessible, an accessible route from the last accessible hole to the course exit or entrance must not require travel back through other holes. In some cases, this may require an additional accessible route. Other options include increasing the number of accessible holes in a way that limits the distance needed to connect the last accessible hole with the course exit or entrance. 240 PLAY AREAS 240.1 General. Play areas for children ages 2 and over shall comply with 240. Where separate play areas are provided within a site for specific age groups, each play area shall comply with 240. EXCEPTIONS: 1. Play areas located in family child care facilities where the proprietor actually resides shall not be required to comply with 240. 2. In existing play areas, where play components are relocated for the purposes of creating safe use zones and the ground surface is not altered or extended for more than one use zone, the play area shall not be required to comply with 240. 3. Amusement attractions shall not be required to comply with 240. 4. Where play components are altered and the ground surface is not altered, the ground surface shall not be required to comply with 1008.2.6 unless required by 202.4. Advisory 240.1 General. Play areas may be located on exterior sites or within a building. Where separate play areas are provided within a site for children in specified age groups (e.g., preschool (ages 2 to 5) and school age (ages 5 to 12)), each play area must comply with this section. Where play areas are provided for the same age group on a site but are geographically separated (e.g., one is located next to a picnic area and another is located next to a softball field), they are considered separate play areas and each play area must comply with this section. 240.1.1 Additions. Where play areas are designed and constructed in phases, the requirements of 240 shall apply to each successive addition so that when the addition is completed, the entire play area complies with all the applicable requirements of 240. Advisory 240.1.1 Additions. These requirements are to be applied so that when each successive addition is completed, the entire play area complies with all applicable provisions. For example, a play area is built in two phases. In the first phase, there are 10 elevated play components and 10 elevated play components are added in the second phase for a total of 20 elevated play components in the play area. When the first phase was completed, at least 5 elevated play components, including at least 3 different types, were to be provided on an accessible route. When the second phase is completed, at least 10 elevated play components must be located on an accessible route, and at least 7 ground level play components, including 4 different types, must be provided on an accessible route. At the time the second phase is complete, ramps must be used to connect at least 5 of the elevated play components and transfer systems are permitted to be used to connect the rest of the elevated play components required to be located on an accessible route. 240.2 Play Components. Where provided, play components shall comply with 240.2. 240.2.1 Ground Level Play Components. Ground level play components shall be provided in the number and types required by 240.2.1. Ground level play components that are provided to comply with 240.2.1.1 shall be permitted to satisfy the additional number required by 240.2.1.2 if the minimum required types of play components are satisfied. Where two or more required ground level play components are provided, they shall be dispersed throughout the play area and integrated with other play components. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 57 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 2: SCOPING REQUIREMENTS SCOPING Advisory 240.2.1 Ground Level Play Components. Examples of ground level play components may include spring rockers, swings, diggers, and stand-alone slides. When distinguishing between the different types of ground level play components, consider the general experience provided by the play component. Examples of different types of experiences include, but are not limited to, rocking, swinging, climbing, spinning, and sliding. A spiral slide may provide a slightly different experience from a straight slide, but sliding is the general experience and therefore a spiral slide is not considered a different type of play component from a straight slide. Ground level play components accessed by children with disabilities must be integrated into the play area. Designers should consider the optimal layout of ground level play components accessed by children with disabilities to foster interaction and socialization among all children. Grouping all ground level play components accessed by children with disabilities in one location is not considered integrated. Where a stand-alone slide is provided, an accessible route must connect the base of the stairs at the entry point to the exit point of the slide. A ramp or transfer system to the top of the slide is not required. Where a sand box is provided, an accessible route must connect to the border of the sand box. Accessibility to the sand box would be enhanced by providing a transfer system into the sand or by providing a raised sand table with knee clearance complying with 1008.4.3. Ramps are preferred over transfer systems since not all children who use wheelchairs or other mobility devices may be able to use, or may choose not to use, transfer systems. Where ramps connect elevated play components, the maximum rise of any ramp run is limited to 12 inches (305 mm). Where possible, designers and operators are encouraged to provide ramps with a slope less than the 1:12 maximum. Berms or sculpted dirt may be used to provide elevation and may be part of an accessible route to composite play structures. Platform lifts are permitted as a part of an accessible route. Because lifts must be independently operable, operators should carefully consider the appropriateness of their use in unsupervised settings. 240.2.1.1 Minimum Number and Types. Where ground level play components are provided, at least one of each type shall be on an accessible route and shall comply with 1008.4. 240.2.1.2 Additional Number and Types. Where elevated play components are provided, ground level play components shall be provided in accordance with Table 240.2.1.2 and shall comply with 1008.4. EXCEPTION: If at least 50 percent of the elevated play components are connected by a ramp and at least 3 of the elevated play components connected by the ramp are different types of play components, the play area shall not be required to comply with 240.2.1.2. Advisory 240.2.1.2 Additional Number and Types. Where a large play area includes two or more composite play structures designed for the same age group, the total number of elevated play components on all the composite play structures must be added to determine the additional number and types of ground level play components that must be provided on an accessible route. 58 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 SCOPING CHAPTER 2: SCOPING REQUIREMENTS Table 240.2.1.2 Number and Types of Ground Level Play Components Required to be on Accessible Routes Number of Elevated Play Components Provided 1 2 to 4 5 to 7 8 to 10 11 to 13 14 to 16 17 to 19 20 to 22 23 to 25 26 and over Minimum Number of Ground Level Play Components Required to be on an Accessible Route Minimum Number of Different Types of Ground Level Play Components Required to be on an Accessible Route Not applicable 1 2 3 4 5 6 7 8 8, plus 1 for each additional 3, or fraction thereof, over 25 Not applicable 1 2 3 3 3 3 4 4 5 240.2.2 Elevated Play Components. Where elevated play components are provided, at least 50 percent shall be on an accessible route and shall comply with 1008.4. Advisory 240.2.2 Elevated Play Components. A double or triple slide that is part of a composite play structure is one elevated play component. For purposes of this section, ramps, transfer systems, steps, decks, and roofs are not considered elevated play components. Although socialization and pretend play can occur on these elements, they are not primarily intended for play. Some play components that are attached to a composite play structure can be approached or exited at the ground level or above grade from a platform or deck. For example, a climber attached to a composite play structure can be approached or exited at the ground level or above grade from a platform or deck on a composite play structure. Play components that are attached to a composite play structure and can be approached from a platform or deck (e.g., climbers and overhead play components) are considered elevated play components. These play components are not considered ground level play components and do not count toward the requirements in 240.2.1.2 regarding the number of ground level play components that must be located on an accessible route. 241 SAUNAS AND STEAM ROOMS 241 General. Where provided, saunas and steam rooms shall comply with 612. EXCEPTION: Where saunas or steam rooms are clustered at a single location, no more than 5 percent of the saunas and steam rooms, but no fewer than one, of each type in each cluster shall be required to comply with 612. 242 SWIMMING POOLS, WADING POOLS, AND SPAS 242.1 General. Swimming pools, wading pools, and spas shall comply with 242. 242.2 Swimming Pools. At least two accessible means of entry shall be provided for swimming pools. Accessible means of entry shall be swimming pool lifts complying with 1009.2; sloped entries complying with 1009.3; transfer walls complying with 1009.4; transfer systems complying with 1009.5; and pool stairs complying with 1009.6. At least one accessible means of entry provided shall comply with 1009.2 or 1009.3. EXCEPTIONS: 1. Where a swimming pool has less than 300 linear feet (91 m) of swimming pool wall, no more than one accessible means of entry shall be required provided that the accessible means of entry is a swimming pool lift complying with 1009.2 or sloped entry complying with 1009.3. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 59 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 2: SCOPING REQUIREMENTS SCOPING 2. Wave action pools, leisure rivers, sand bottom pools, and other pools where user access is limited to one area shall not be required to provide more than one accessible means of entry provided that the accessible means of entry is a swimming pool lift complying with 1009.2, a sloped entry complying with 1009.3, or a transfer system complying with 1009.5. 3. Catch pools shall not be required to provide an accessible means of entry provided that the catch pool edge is on an accessible route. Advisory 242.2 Swimming Pools. Where more than one means of access is provided into the water, it is recommended that the means be different. Providing different means of access will better serve the varying needs of people with disabilities in getting into and out of a swimming pool. It is also recommended that where two or more means of access are provided, they not be provided in the same location in the pool. Different locations will provide increased options for entry and exit, especially in larger pools. Advisory 242.2 Swimming Pools Exception 1. Pool walls at diving areas and areas along pool walls where there is no pool entry because of landscaping or adjacent structures are to be counted when determining the number of accessible means of entry required. 242.3 Wading Pools. At least one accessible means of entry shall be provided for wading pools. Accessible means of entry shall comply with sloped entries complying with 1009.3. 242.4 Spas. At least one accessible means of entry shall be provided for spas. Accessible means of entry shall comply with swimming pool lifts complying with 1009.2; transfer walls complying with 1009.4; or transfer systems complying with 1009.5. EXCEPTION: Where spas are provided in a cluster, no more than 5 percent, but no fewer than one, spa in each cluster shall be required to comply with 242.4. 243 SHOOTING FACILITIES WITH FIRING POSITIONS 243.1 General. Where shooting facilities with firing positions are designed and constructed at a site, at least 5 percent, but no fewer than one, of each type of firing position shall comply with 1010. 60 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 3: BUILDING BLOCKS 301 GENERAL 301.1 Scope. The provisions of Chapter 3 shall apply where required by Chapter 2 or where referenced by a requirement in this code. 302 FLOOR OR GROUND SURFACES 302.1 General. Floor and ground surfaces shall be stable, firm, and slip resistant and shall comply with 302. EXCEPTIONS: 1. Within animal containment areas, floor and ground surfaces shall not be required to be stable, firm, and slip resistant. 2. Areas of sport activity shall not be required to comply with 302. Advisory 302.1 General. A stable surface is one that remains unchanged by contaminants or applied force, so that when the contaminant or force is removed, the surface returns to its original condition. A firm surface resists deformation by either indentations or particles moving on its surface. A slip-resistant surface provides sufficient frictional counterforce to the forces exerted in walking to permit safe ambulation. 302.2 Carpet. Carpet or carpet tile shall be securely attached and shall have a firm cushion, pad, or backing or no cushion or pad. Carpet or carpet tile shall have a level loop, textured loop, level cut pile, or level cut/uncut pile texture. Pile height shall be 1/2 inch (13 mm) maximum. Exposed edges of carpet shall be fastened to floor surfaces and shall have trim on the entire length of the exposed edge. Carpet edge trim shall comply with 303. Advisory 302.2 Carpet. Carpets and permanently affixed mats can significantly increase the amount of force (roll resistance) needed to propel a wheelchair over a surface. The firmer the carpeting and backing, the lower the roll resistance. A pile thickness up to 1/2 inch (13 mm) (measured to the backing, cushion, or pad) is allowed, although a lower pile provides easier wheelchair maneuvering. If a backing, cushion or pad is used, it must be firm. Preferably, carpet pad should not be used because the soft padding increases roll resistance. FIGURE 302.2 CARPET PILE HEIGHT 302.3 Openings. Openings in floor or ground surfaces shall not allow passage of a sphere more than 1/2 inch (13 mm) diameter except as allowed in 407.4.3, 409.4.3, 410.4, 810.5.3 and 810.10. Elongated openings shall be placed so that the long dimension is perpendicular to the dominant direction of travel. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 61 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 3: BUILDING BLOCKS TECHNICAL FIGURE 302.3 ELONGATED OPENINGS IN FLOOR OR GROUND SURFACES 303 CHANGES IN LEVEL 303.1 General. Where changes in level are permitted in floor or ground surfaces, they shall comply with 303. EXCEPTIONS: 1. Animal containment areas shall not be required to comply with 303. 2. Areas of sport activity shall not be required to comply with 303. 303.2 Vertical. Changes in level of 1/4 inch (6.4 mm) high maximum shall be permitted to be vertical. FIGURE 303.2 VERTICAL CHANGE IN LEVEL 303.3 Beveled. Changes in level between 1/4 inch (6.4 mm) high minimum and 1/2 inch (13 mm) high maximum shall be beveled with a slope not steeper than 1:2. Advisory 303.3 Beveled. A change in level of 1/2 inch (13 mm) is permitted to be 1/4 inch (6.4 mm) vertical plus 1/4 inch (6.4 mm) beveled. However, in no case may the combined change in level exceed 1/2 inch (13 mm). Changes in level exceeding 1/2 inch (13 mm) must comply with 405 (Ramps) or 406 (Curb Ramps). FIGURE 303.3 BEVELED CHANGE IN LEVEL 62 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 TECHNICAL CHAPTER 3: BUILDING BLOCKS 303.4 Ramps. Changes in level greater than 1/2 inch (13 mm) high shall be ramped, and shall comply with 405 or 406. 304 TURNING SPACE 304.1 General. Turning space shall comply with 304. 304.2 Floor or Ground Surfaces. Floor or ground surfaces of a turning space shall comply with 302. Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted. Advisory 304.2 Floor or Ground Surface Exception. As used in this section, the phrase “changes in level” refers to surfaces with slopes and to surfaces with abrupt rise exceeding that permitted in Section 303.3. Such changes in level are prohibited in required clear floor and ground spaces, turning spaces, and in similar spaces where people using wheelchairs and other mobility devices must park their mobility aids such as in wheelchair spaces, or maneuver to use elements such as at doors, fixtures, and telephones. The exception permits slopes not steeper than 1:48. 304.3 Size. Turning space shall comply with 304.3.1 or 304.3.2. 304.3.1 Circular Space. The turning space shall be a space of 60 inches (1525 mm) diameter minimum. The space shall be permitted to include knee and toe clearance complying with 306. 304.3.2 T-Shaped Space. The turning space shall be a T-shaped space within a 60 inch (1525 mm) square minimum with arms and base 36 inches (915 mm) wide minimum. Each arm of the T shall be clear of obstructions 12 inches (305 mm) minimum in each direction and the base shall be clear of obstructions 24 inches (610 mm) minimum. The space shall be permitted to include knee and toe clearance complying with 306 only at the end of either the base or one arm. FIGURE 304.3.2 T-SHAPED TURNING SPACE 304.4 Door Swing. Doors shall be permitted to swing into turning spaces. 305 CLEAR FLOOR OR GROUND SPACE 305.1 General. Clear floor or ground space shall comply with 305. 305.2 Floor or Ground Surfaces. Floor or ground surfaces of a clear floor or ground space shall comply with 302. Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted. 305.3 Size. The clear floor or ground space shall be 30 inches (760 mm) minimum by 48 inches (1220 mm) minimum. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 63 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 3: BUILDING BLOCKS TECHNICAL FIGURE 305.3 CLEAR FLOOR OR GROUND SPACE 305.4 Knee and Toe Clearance. Unless otherwise specified, clear floor or ground space shall be permitted to include knee and toe clearance complying with 306. 305.5 Position. Unless otherwise specified, clear floor or ground space shall be positioned for either forward or parallel approach to an element. FIGURE 305.5 POSITION OF CLEAR FLOOR OR GROUND SPACE 305.6 Approach. One full unobstructed side of the clear floor or ground space shall adjoin an accessible route or adjoin another clear floor or ground space. 305.7 Maneuvering Clearance. Where a clear floor or ground space is located in an alcove or otherwise confined on all or part of three sides, additional maneuvering clearance shall be provided in accordance with 305.7.1 and 305.7.2. 305.7.1 Forward Approach. Alcoves shall be 36 inches (915 mm) wide minimum where the depth exceeds 24 inches (610 mm). FIGURE 305.7.1 MANEUVERING CLEARANCE IN AN ALCOVE, FORWARD APPROACH 64 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 TECHNICAL CHAPTER 3: BUILDING BLOCKS 305.7.2 Parallel Approach. Alcoves shall be 60 inches (1525 mm) wide minimum where the depth exceeds 15 inches (380 mm). FIGURE 305.7.2 MANEUVERING CLEARANCE IN AN ALCOVE, PARALLEL APPROACH 306 KNEE AND TOE CLEARANCE 306.1 General. Where space beneath an element is included as part of clear floor or ground space or turning space, the space shall comply with 306. Additional space shall not be prohibited beneath an element but shall not be considered as part of the clear floor or ground space or turning space. Advisory 306.1 General. Clearances are measured in relation to the usable clear floor space, not necessarily to the vertical support for an element. When determining clearance under an object for required turning or maneuvering space, care should be taken to ensure the space is clear of any obstructions. 306.2 Toe Clearance. FIGURE 306.2 TOE CLEARANCE 306.2.1 General. Space under an element between the finish floor or ground and 9 inches (230 mm) above the finish floor or ground shall be considered toe clearance and shall comply with 306.2. 306.2.2 Maximum Depth. Toe clearance shall extend 25 inches (635 mm) maximum under an element. 306.2.3 Minimum Required Depth. Where toe clearance is required at an element as part of a clear floor space, the toe clearance shall extend 17 inches (430 mm) minimum under the element. 306.2.4 Additional Clearance. Space extending greater than 6 inches (150 mm) beyond the available knee clearance at 9 inches (230 mm) above the finish floor or ground shall not be considered toe clearance. 306.2.5 Width. Toe clearance shall be 30 inches (760 mm) wide minimum. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 65 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 3: BUILDING BLOCKS TECHNICAL 306.3 Knee Clearance. FIGURE 306.3 KNEE CLEARANCE 306.3.1 General. Space under an element between 9 inches (230 mm) and 27 inches (685 mm) above the finish floor or ground shall be considered knee clearance and shall comply with 306.3. 306.3.2 Maximum Depth. Knee clearance shall extend 25 inches (635 mm) maximum under an element at 9 inches (230 mm) above the finish floor or ground. 306.3.3 Minimum Required Depth. Where knee clearance is required under an element as part of a clear floor space, the knee clearance shall be 11 inches (280 mm) deep minimum at 9 inches (230 mm) above the finish floor or ground, and 8 inches (205 mm) deep minimum at 27 inches (685 mm) above the finish floor or ground. 306.3.4 Clearance Reduction. Between 9 inches (230 mm) and 27 inches (685 mm) above the finish floor or ground, the knee clearance shall be permitted to reduce at a rate of 1 inch (25 mm) in depth for each 6 inches (150 mm) in height. 306.3.5 Width. Knee clearance shall be 30 inches (760 mm) wide minimum. 307 PROTRUDING OBJECTS 307.1 General. Protruding objects shall comply with 307. 307.2 Protrusion Limits. Objects with leading edges more than 27 inches (685 mm) and not more than 80 inches (2030 mm) above the finish floor or ground shall protrude 4 inches (100 mm) maximum horizontally into the circulation path. EXCEPTION: Handrails shall be permitted to protrude 41/2 inches (115 mm) maximum. Advisory 307.2 Protrusion Limits. When a cane is used and the element is in the detectable range, it gives a person sufficient time to detect the element with the cane before there is body contact. Elements located on circulation paths, including operable elements, must comply with requirements for protruding objects. For example, awnings and their supporting structures cannot reduce the minimum required vertical clearance. Similarly, casement windows, when open, cannot encroach more than 4 inches (100 mm) into circulation paths above 27 inches (685 mm). 66 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 TECHNICAL CHAPTER 3: BUILDING BLOCKS FIGURE 307.2 LIMITS OF PROTRUDING OBJECTS 307.3 Post-Mounted Objects. Free-standing objects mounted on posts or pylons shall overhang circulation paths 12 inches (305 mm) maximum when located 27 inches (685 mm) minimum and 80 inches (2030 mm) maximum above the finish floor or ground. Where a sign or other obstruction is mounted between posts or pylons and the clear distance between the posts or pylons is greater than 12 inches (305 mm), the lowest edge of such sign or obstruction shall be 27 inches (685 mm) maximum or 80 inches (2030 mm) minimum above the finish floor or ground. EXCEPTION: The sloping portions of handrails serving stairs and ramps shall not be required to comply with 307.3. FIGURE 307.3 POST-MOUNTED PROTRUDING OBJECTS 307.4 Vertical Clearance. Vertical clearance shall be 80 inches (2030 mm) high minimum. Guardrails or other barriers shall be provided where the vertical clearance is less than 80 inches (2030 mm) high. The leading edge of such guardrail or barrier shall be located 27 inches (685 mm) maximum above the finish floor or ground. EXCEPTION: Door closers and door stops shall be permitted to be 78 inches (1980 mm) minimum above the finish floor or ground. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 67 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 3: BUILDING BLOCKS TECHNICAL FIGURE 307.4 VERTICAL CLEARANCE 307.5 Required Clear Width. Protruding objects shall not reduce the clear width required for accessible routes. 308 REACH RANGES 308.1 General. Reach ranges shall comply with 308. Advisory 308.1 General. The following table provides guidance on reach ranges for children according to age where building elements such as coat hooks, lockers, or operable parts are designed for use primarily by children. These dimensions apply to either forward or side reaches. Accessible elements and operable parts designed for adult use or children over age 12 can be located outside these ranges but must be within the adult reach ranges required by 308. Children’s Reach Ranges Forward or Side Reach Ages 3 and 4 Ages 5 through 8 Ages 9 through 12 High (maximum) Low (minimum) 36 in (915 mm) 20 in (510 mm) 40 in (1015 mm) 18 in (455 mm) 44 in (1120 mm) 16 in (405 mm) 308.2 Forward Reach. 308.2.1 Unobstructed. Where a forward reach is unobstructed, the high forward reach shall be 48 inches (1220 mm) maximum and the low forward reach shall be 15 inches (380 mm) minimum above the finish floor or ground. FIGURE 308.2.1 UNOBSTRUCTED FORWARD REACH 308.2.2 Obstructed High Reach. Where a high forward reach is over an obstruction, the clear floor space shall extend beneath the element for a distance not less than the required reach depth over the obstruction. The high forward reach shall be 48 inches (1220 mm) maximum where the reach depth is 20 inches (510 mm) maximum. Where the reach depth exceeds 20 inches (510 mm), the high forward reach shall be 44 inches (1120 mm) maximum and the reach depth shall be 25 inches (635 mm) maximum. 68 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 TECHNICAL CHAPTER 3: BUILDING BLOCKS FIGURE 308.2.2 OBSTRUCTED HIGH FORWARD REACH 308.3 Side Reach. 308.3.1 Unobstructed. Where a clear floor or ground space allows a parallel approach to an element and the side reach is unobstructed, the high side reach shall be 48 inches (1220 mm) maximum and the low side reach shall be 15 inches (380 mm) minimum above the finish floor or ground. EXCEPTIONS: 1. An obstruction shall be permitted between the clear floor or ground space and the element where the depth of the obstruction is 10 inches (255 mm) maximum. 2. Operable parts of fuel dispensers shall be permitted to be 54 inches (1370 mm) maximum measured from the surface of the vehicular way where fuel dispensers are installed on existing curbs. FIGURE 308.3.1 UNOBSTRUCTED SIDE REACH 308.3.2 Obstructed High Reach. Where a clear floor or ground space allows a parallel approach to an element and the high side reach is over an obstruction, the height of the obstruction shall be 34 inches (865 mm) maximum and the depth of the obstruction shall be 24 inches (610 mm) maximum. The high side reach shall be 48 inches (1220 mm) maximum for a reach depth of 10 inches (255 mm) maximum. Where the reach depth exceeds 10 inches (255 mm), the high side reach shall be 46 inches (1170 mm) maximum for a reach depth of 24 inches (610 mm) maximum. EXCEPTIONS: 1. The top of washing machines and clothes dryers shall be permitted to be 36 inches (915 mm) maximum above the finish floor. 2. Operable parts of fuel dispensers shall be permitted to be 54 inches (1370 mm) maximum measured from the surface of the vehicular way where fuel dispensers are installed on existing curbs. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 69 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 3: BUILDING BLOCKS TECHNICAL FIGURE 308.3.2 OBSTRUCTED HIGH SIDE REACH 309 OPERABLE PARTS 309.1 General. Operable parts shall comply with 309. 309.2 Clear Floor Space. A clear floor or ground space complying with 305 shall be provided. 309.3 Height. Operable parts shall be placed within one or more of the reach ranges specified in 308. 309.4 Operation. Operable parts shall be operable with one hand and shall not require tight grasping, pinching, or twisting of the wrist. The force required to activate operable parts shall be 5 pounds (22.2 N) maximum. EXCEPTION: Gas pump nozzles shall not be required to provide operable parts that have an activating force of 5 pounds (22.2 N) maximum. 70 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 4: ACCESSIBLE ROUTES 401 GENERAL 401.1 Scope. The provisions of Chapter 4 shall apply where required by Chapter 2 or where referenced by a requirement in this code. 402 ACCESSIBLE ROUTES 402.1 General. Accessible routes shall comply with 402. 402.2 Components. Accessible routes shall consist of one or more of the following components: walking surfaces with a running slope not steeper than 1:20, doorways, ramps, curb ramps excluding the flared sides, elevators, and platform lifts. All components of an accessible route shall comply with the applicable requirements of Chapter 4 and 208.3.1. Advisory 402.2 Components. Walking surfaces must have running slopes not steeper than 1:20, see 403.3. Other components of accessible routes, such as ramps (405) and curb ramps (406), are permitted to be more steeply sloped. Florida requirements of s.553.5041, F.S., incorporated in section 208.3.1 for accessible routes to parking that modify requirements of Chapter 4 must be complied with. Pursuant to s.553.512, F.S., Florida requirements, except s.553.5041(5)(a) width of accessible route to parking and s.553.041(c)1 parking space and access aisle width, may be waived down to the requirements of the ADA Standards for Accessible Design. 403 WALKING SURFACES 403.1 General. Walking surfaces that are a part of an accessible route shall comply with 403. 403.2 Floor or Ground Surface. Floor or ground surfaces shall comply with 302. 403.3 Slope. The running slope of walking surfaces shall not be steeper than 1:20. The cross slope of walking surfaces shall not be steeper than 1:48. 403.4 Changes in Level. Changes in level shall comply with 303. 403.5 Clearances. Walking surfaces shall provide clearances complying with 403.5. EXCEPTION: Within employee work areas, clearances on common use circulation paths shall be permitted to be decreased by work area equipment provided that the decrease is essential to the function of the work being performed. 403.5.1 Clear Width. Except as provided in 403.5.2 and 403.5.3, the clear width of walking surfaces shall be 36 inches (915 mm) minimum. EXCEPTION: The clear width shall be permitted to be reduced to 32 inches (815 mm) minimum for a length of 24 inches (610 mm) maximum provided that reduced width segments are separated by segments that are 48 inches (1220 mm) long minimum and 36 inches (915 mm) wide minimum. FIGURE 403.5.1 CLEAR WIDTH OF AN ACCESSIBLE ROUTE FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 71 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 4: ACCESSIBLE ROUTES TECHNICAL 403.5.2 Clear Width at Turn. Where the accessible route makes a 180 degree turn around an element which is less than 48 inches (1220 mm) wide, clear width shall be 42 inches (1065 mm) minimum approaching the turn, 48 inches (1220 mm) minimum at the turn and 42 inches (1065 mm) minimum leaving the turn. EXCEPTION: Where the clear width at the turn is 60 inches (1525 mm) minimum compliance with 403.5.2 shall not be required. FIGURE 403.5.2 CLEAR WIDTH AT TURN 403.5.3 Passing Spaces. An accessible route with a clear width less than 60 inches (1525 mm) shall provide passing spaces at intervals of 200 feet (61 m) maximum. Passing spaces shall be either: a space 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum; or, an intersection of two walking surfaces providing a T-shaped space complying with 304.3.2 where the base and arms of the T-shaped space extend 48 inches (1220 mm) minimum beyond the intersection. 403.6 Handrails. Where handrails are provided along walking surfaces with running slopes not steeper than 1:20 they shall comply with 505. Advisory 403.6 Handrails. Handrails provided in elevator cabs and platform lifts are not required to comply with the requirements for handrails on walking surfaces. 404 DOORS, DOORWAYS, AND GATES 404.1 General. Doors, doorways, and gates that are part of an accessible route shall comply with 404. EXCEPTION: Doors, doorways, and gates designed to be operated only by security personnel shall not be required to comply with 404.2.7, 404.2.8, 404.2.9, 404.3.2 and 404.3.4 through 404.3.7. Advisory 404.1 General Exception. Security personnel must have sole control of doors that are eligible for the Exception at 404.1. It would not be acceptable for security personnel to operate the doors for people with disabilities while allowing others to have independent access. 404.2 Manual Doors, Doorways, and Manual Gates. Manual doors and doorways and manual gates intended for user passage shall comply with 404.2. 404.2.1 Revolving Doors, Gates, and Turnstiles. Revolving doors, revolving gates, and turnstiles shall not be part of an accessible route. 404.2.2 Double-Leaf Doors and Gates. At least one of the active leaves of doorways with two leaves shall comply with 404.2.3 and 404.2.4. 404.2.3 Clear Width. Door openings shall provide a clear width of 32 inches (815 mm) minimum. Clear openings of doorways with swinging doors shall be measured between the face of the door and the stop, with the door open 90 degrees. Openings more than 24 inches (610 mm) deep shall provide a clear opening of 36 inches (915 mm) minimum. There shall be no projections into the required clear opening width lower than 34 inches (865 mm) 72 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 TECHNICAL CHAPTER 4: ACCESSIBLE ROUTES above the finish floor or ground. Projections into the clear opening width between 34 inches (865 mm) and 80 inches (2030 mm) above the finish floor or ground shall not exceed 4 inches (100 mm). EXCEPTIONS: 1. In alterations, a projection of 5/8 inch (16 mm) maximum into the required clear width shall be permitted for the latch side stop. 2. Door closers and door stops shall be permitted to be 78 inches (1980 mm) minimum above the finish floor or ground. FIGURE 404.2.3 CLEAR WIDTH OF DOORWAYS 404.2.4 Maneuvering Clearances. Minimum maneuvering clearances at doors and gates shall comply with 404.2.4. Maneuvering clearances shall extend the full width of the doorway and the required latch side or hinge side clearance. EXCEPTION: Entry doors to hospital patient rooms shall not be required to provide the clearance beyond the latch side of the door. 404.2.4.1 Swinging Doors and Gates. Swinging doors and gates shall have maneuvering clearances complying with Table 404.2.4.1. TABLE 404.2.4.1 MANEUVERING CLEARANCE AT MANUAL SWINGING DOORS AND GATES Type of Use Approach Direction Door or Gate Side From front From front From hinge side From hinge side From hinge side From latch side From latch side Pull Push Pull Pull Push Pull Push Minimum Maneuvering Clearance Parallel to Doorway Perpendicular to Doorway (beyond latch side unless noted) 60 inches (1525 mm) 48 inches (1220 mm) 60 inches (1525 mm) 54 inches (1370 mm) 42 inches (1065 mm)2 48 inches (1220 mm)4 42 inches (1065 mm)4 18 inches (455 mm) 0 inches (0 mm)1 36 inches (915 mm) 42 inches (1065 mm) 22 inches (560 mm)3 24 inches (610 mm) 24 inches (610 mm) 1. Add 12 inches (305 mm) if closer and latch are provided. 2. Add 6 inches (150 mm) if closer and latch are provided. 3. Beyond hinge side. 4. Add 6 inches (150 mm) if closer is provided. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 73 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 4: ACCESSIBLE ROUTES TECHNICAL FIGURE 404.2.4.1 MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS AND GATES 74 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 TECHNICAL CHAPTER 4: ACCESSIBLE ROUTES FIGURE 404.2.4.1—CONTINUED MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS AND GATES FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 75 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 4: ACCESSIBLE ROUTES TECHNICAL 404.2.4.2 Doorways without Doors or Gates, Sliding Doors, and Folding Doors. Doorways less than 36 inches (915 mm) wide without doors or gates, sliding doors, or folding doors shall have maneuvering clearances complying with Table 404.2.4.2. TABLE 404.2.4.2 MANEUVERING CLEARANCES AT DOORWAYS WITHOUT DOORS OR GATES, MANUAL SLIDING DOORS, AND MANUAL FOLDING DOORS Minimum Maneuvering Clearance Parallel to Doorway Approach Direction Perpendicular to Doorway (beyond stop/latch side unless noted) From Front From side1 From pocket/hinge side From stop/latch side 48 inches (1220 mm) 42 inches (1065 mm) 42 inches (1065 mm) 42 inches (1065 mm) 0 inches (0 mm) 0 inches (0 mm) 22 inches (560 mm)2 24 inches (610 mm) 1. Doorway with no door only. 2. Beyond pocket/hinge side. FIGURE 404.2.4.2 MANEUVERING CLEARANCES AT DOORWAYS WITHOUT DOORS, SLIDING DOORS, GATES, AND FOLDING DOORS 404.2.4.3 Recessed Doors and Gates. Maneuvering clearances for forward approach shall be provided when any obstruction within 18 inches (455 mm) of the latch side of a doorway projects more than 8 inches (205 mm) beyond the face of the door, measured perpendicular to the face of the door or gate. Advisory 404.2.4.3 Recessed Doors and Gates. A door can be recessed due to wall thickness or because of the placement of casework and other fixed elements adjacent to the doorway. This provision must be applied wherever doors are recessed. 76 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 TECHNICAL CHAPTER 4: ACCESSIBLE ROUTES FIGURE 404.2.4.3 MANEUVERING CLEARANCES AT RECESSED DOORS AND GATES 404.2.4.4 Floor or Ground Surface. Floor or ground surface within required maneuvering clearances shall comply with 302. Changes in level are not permitted. EXCEPTIONS: 1. Slopes not steeper than 1:48 shall be permitted. 2. Changes in level at thresholds complying with 404.2.5 shall be permitted. 404.2.5 Thresholds. Thresholds, if provided at doorways, shall be 1/2 inch (13 mm) high maximum. Raised thresholds and changes in level at doorways shall comply with 302 and 303. EXCEPTION: Existing or altered thresholds 3/4 inch (19 mm) high maximum that have a beveled edge on each side with a slope not steeper than 1:2 shall not be required to comply with 404.2.5. 404.2.6 Doors in Series and Gates in Series. The distance between two hinged or pivoted doors in series and gates in series shall be 48 inches (1220 mm) minimum plus the width of doors or gates swinging into the space. FIGURE 404.2.6 DOORS IN SERIES AND GATES IN SERIES FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 77 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 4: ACCESSIBLE ROUTES TECHNICAL 404.2.7 Door and Gate Hardware. Handles, pulls, latches, locks, and other operable parts on doors and gates shall comply with 309.4. Operable parts of such hardware shall be 34 inches (865 mm) minimum and 48 inches (1220 mm) maximum above the finish floor or ground. Where sliding doors are in the fully open position, operating hardware shall be exposed and usable from both sides. EXCEPTIONS: 1. Existing locks shall be permitted in any location at existing glazed doors without stiles, existing overhead rolling doors or grilles, and similar existing doors or grilles that are designed with locks that are activated only at the top or bottom rail. 2. Access gates in barrier walls and fences protecting pools, spas, and hot tubs shall be permitted to have operable parts of the release of latch on self-latching devices at 54 inches (1370 mm) maximum above the finish floor or ground provided the self-latching devices are not also self-locking devices and operated by means of a key, electronic opener, or integral combination lock. Advisory 404.2.7 Door and Gate Hardware. Door hardware that can be operated with a closed fist or a loose grip accommodates the greatest range of users. Hardware that requires simultaneous hand and finger movements require greater dexterity and coordination, and is not recommended. 404.2.8 Closing Speed. Door and gate closing speed shall comply with 404.2.8. 404.2.8.1 Door Closers and Gate Closers. Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum. 404.2.8.2 Spring Hinges. Door and gate spring hinges shall be adjusted so that from the open position of 70 degrees, the door or gate shall move to the closed position in 1.5 seconds minimum. 404.2.9 Door and Gate Opening Force. Fire doors shall have a minimum opening force allowable by the appropriate administrative authority. The force for pushing or pulling open a door or gate other than fire doors shall be as follows: 1. Interior hinged doors and gates: 5 pounds (22.2 N) maximum. 2. Sliding or folding doors: 5 pounds (22.2 N) maximum. 3. Exterior hinged doors shall be designed so that such doors can be pushed or pulled open with a force not exceeding 8.5 pounds (37.8 N). These forces do not apply to the force required to retract latch bolts or disengage other devices that hold the door or gate in a closed position. Advisory 404.2.9 Door and Gate Opening Force. The maximum force pertains to the continuous application of force necessary to fully open a door, not the initial force needed to overcome the inertia of the door. It does not apply to the force required to retract bolts or to disengage other devices used to keep the door in a closed position. Florida law, s.553.504(6), F.S., establishes requirements for exterior door opening force. 404.2.10 Door and Gate Surfaces. Swinging door and gate surfaces within 10 inches (255 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door or gate. Parts creating horizontal or vertical joints in these surfaces shall be within 1/16 inch (1.6 mm) of the same plane as the other. Cavities created by added kick plates shall be capped. EXCEPTIONS: 1. Sliding doors shall not be required to comply with 404.2.10. 2. Tempered glass doors without stiles and having a bottom rail or shoe with the top leading edge tapered at 60 degrees minimum from the horizontal shall not be required to meet the 10 inch (255 mm) bottom smooth surface height requirement. 3. Doors and gates that do not extend to within 10 inches (255 mm) of the finish floor or ground shall not be required to comply with 404.2.10. 78 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 TECHNICAL CHAPTER 4: ACCESSIBLE ROUTES 4. Existing doors and gates without smooth surfaces within 10 inches (255 mm) of the finish floor or ground shall not be required to provide smooth surfaces complying with 404.2.10 provided that if added kick plates are installed, cavities created by such kick plates are capped. 404.2.11 Vision Lights. Doors, gates, and side lights adjacent to doors or gates, containing one or more glazing panels that permit viewing through the panels shall have the bottom of at least one glazed panel located 43 inches (1090 mm) maximum above the finish floor. EXCEPTION: Vision lights with the lowest part more than 66 inches (1675 mm) from the finish floor or ground shall not be required to comply with 404.2.11. 404.3 Automatic and Power-Assisted Doors and Gates. Automatic doors and automatic gates shall comply with 404.3. Full-powered automatic doors shall comply with ANSI/BHMA A156.10 (incorporated by reference, see “Referenced Standards” in Chapter 1). Low-energy and power-assisted doors shall comply with ANSI/BHMA A156.19 (1997 or 2002 edition) (incorporated by reference, see “Referenced Standards” in Chapter 1). 404.3.1 Clear Width. Doorways shall provide a clear opening of 32 inches (815 mm) minimum in power-on and power-off mode. The minimum clear width for automatic door systems in a doorway shall be based on the clear opening provided by all leaves in the open position. 404.3.2 Maneuvering Clearance. Clearances at power-assisted doors and gates shall comply with 404.2.4. Clearances at automatic doors and gates without standby power and serving an accessible means of egress shall comply with 404.2.4. EXCEPTION: Where automatic doors and gates remain open in the power-off condition, compliance with 404.2.4 shall not be required. 404.3.3 Thresholds. Thresholds and changes in level at doorways shall comply with 404.2.5. 404.3.4 Doors in Series and Gates in Series. Doors in series and gates in series shall comply with 404.2.6. 404.3.5 Controls. Manually operated controls shall comply with 309. The clear floor space adjacent to the control shall be located beyond the arc of the door swing. 404.3.6 Break Out Opening. Where doors and gates without standby power are a part of a means of egress, the clear break out opening at swinging or sliding doors and gates shall be 32 inches (815 mm) minimum when operated in emergency mode. EXCEPTION: Where manual swinging doors and gates comply with 404.2 and serve the same means of egress compliance with 404.3.6 shall not be required. 404.3.7 Revolving Doors, Revolving Gates, and Turnstiles. Revolving doors, revolving gates, and turnstiles shall not be part of an accessible route. 405 RAMPS 405.1 General. Ramps on accessible routes shall comply with 405. EXCEPTION: In assembly areas, aisle ramps adjacent to seating and not serving elements required to be on an accessible route shall not be required to comply with 405. 405.2 Slope. Ramp runs shall have a running slope not steeper than 1:12. EXCEPTION: In existing sites, buildings, and facilities, ramps shall be permitted to have running slopes steeper than 1:12 complying with Table 405.2 where such slopes are necessary due to space limitations. TABLE 405.2 MAXIMUM RAMP SLOPE AND RISE FOR EXISTING SITES, BUILDINGS, AND FACILITIES Slope1 Steeper than 1:10 but not steeper than 1:8 Steeper than 1:12 but not steeper than 1:10 Maximum Rise 3 inches (75 mm) 6 inches (150 mm) 1. A slope steeper than 1:8 is prohibited. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 79 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 4: ACCESSIBLE ROUTES TECHNICAL Advisory 405.2 Slope. To accommodate the widest range of users, provide ramps with the least possible running slope and, wherever possible, accompany ramps with stairs for use by those individuals for whom distance presents a greater barrier than steps, e.g., people with heart disease or limited stamina. 405.3 Cross Slope. Cross slope of ramp runs shall not be steeper than 1:48. Advisory 405.3 Cross Slope. Cross slope is the slope of the surface perpendicular to the direction of travel. Cross slope is measured the same way as slope is measured (i.e., the rise over the run). 405.4 Floor or Ground Surfaces. Floor or ground surfaces of ramp runs shall comply with 302. Changes in level other than the running slope and cross slope are not permitted on ramp runs. 405.5 Clear Width. The clear width of a ramp run and, where handrails are provided, the clear width between handrails shall be 36 inches (915 mm) minimum. EXCEPTION: Within employee work areas, the required clear width of ramps that are a part of common use circulation paths shall be permitted to be decreased by work area equipment provided that the decrease is essential to the function of the work being performed. 405.6 Rise. The rise for any ramp run shall be 30 inches (760 mm) maximum. 405.7 Landings. Ramps shall have landings at the top and the bottom of each ramp run. Landings shall comply with 405.7. Advisory 405.7 Landings. Ramps that do not have level landings at changes in direction can create a compound slope that will not meet the requirements of this code. Circular or curved ramps continually change direction. Curvilinear ramps with small radii also can create compound cross slopes and cannot, by their nature, meet the requirements for accessible routes. A level landing is needed at the accessible door to permit maneuvering and simultaneously door operation. FIGURE 405.7 RAMP LANDINGS 405.7.1 Slope. Landings shall comply with 302. Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted. 405.7.2 Width. The landing clear width shall be at least as wide as the widest ramp run leading to the landing. 405.7.3 Length. The landing clear length shall be 60 inches (1525 mm) long minimum. 405.7.4 Change in Direction. Ramps that change direction between runs at landings shall have a clear landing 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum. 80 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 TECHNICAL CHAPTER 4: ACCESSIBLE ROUTES 405.7.5 Doorways. Where doorways are located adjacent to a ramp landing, maneuvering clearances required by 404.2.4 and 404.3.2 shall be permitted to overlap the required landing area. 405.8 Handrails. Ramp runs with a rise greater than 6 inches (150 mm) shall have handrails complying with 505. EXCEPTION: Within employee work areas, handrails shall not be required where ramps that are part of common use circulation paths are designed to permit the installation of handrails complying with 505. Ramps not subject to the exception to 405.5 shall be designed to maintain a 36 inch (915 mm) minimum clear width when handrails are installed. 405.9 Edge Protection. Edge protection complying with 405.9.1 or 405.9.2 shall be provided on each side of ramp runs and at each side of ramp landings. EXCEPTIONS: 1. Edge protection shall not be required on ramps that are not required to have handrails and have sides complying with 406.3. 2. Edge protection shall not be required on the sides of ramp landings serving an adjoining ramp run or stairway. 3. Edge protection shall not be required on the sides of ramp landings having a vertical drop-off of 1/2 inch (13 mm) maximum within 10 inches (255 mm) horizontally of the minimum landing area specified in 405.7. 405.9.1 Extended Floor or Ground Surface. The floor or ground surface of the ramp run or landing shall extend 12 inches (305 mm) minimum beyond the inside face of a handrail complying with 505. Advisory 405.9.1 Extended Floor or Ground Surface. The extended surface prevents wheelchair casters and crutch tips from slipping off the ramp surface. FIGURE 405.9.1 EXTENDED FLOOR OR GROUND SURFACE EDGE PROTECTION 405.9.2 Curb or Barrier. A curb or barrier shall be provided that prevents the passage of a 4 inch (100 mm) diameter sphere, where any portion of the sphere is within 4 inches (100 mm) of the finish floor or ground surface. FIGURE 405.9.2 CURB OR BARRIER EDGE PROTECTION 405.10 Wet Conditions. Landings subject to wet conditions shall be designed to prevent the accumulation of water. 406 CURB RAMPS 406.1 General. Curb ramps on accessible routes shall comply with 406, 405.2 through 405.5, and 405.10. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 81 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 4: ACCESSIBLE ROUTES TECHNICAL 406.2 Counter Slope. Counter slopes of adjoining gutters and road surfaces immediately adjacent to the curb ramp shall not be steeper than 1:20. The adjacent surfaces at transitions at curb ramps to walks, gutters, and streets shall be at the same level. FIGURE 406.2 COUNTER SLOPE OF SURFACES ADJACENT TO CURB RAMP 406.3 Sides of Curb Ramps. Where provided, curb ramp flares shall not be steeper than 1:10. FIGURE 406.3 SIDES OF CURB RAMPS 406.4 Landings. Landings shall be provided at the tops of curb ramps. The landing clear length shall be 36 inches (915 mm) minimum. The landing clear width shall be at least as wide as the curb ramp, excluding flared sides, leading to the landing. EXCEPTION: In alterations, where there is no landing at the top of curb ramps, curb ramp flares shall be provided and shall not be steeper than 1:12. FIGURE 406.4 LANDINGS AT THE TOP OF CURB RAMPS 406.5 Location. Curb ramps and the flared sides of curb ramps shall be located so that they do not project into vehicular traffic lanes, parking spaces, or parking access aisles. Curb ramps at marked crossings shall be wholly contained within the markings, excluding any flared sides. 406.6 Diagonal Curb Ramps. Diagonal or corner type curb ramps with returned curbs or other well-defined edges shall have the edges parallel to the direction of pedestrian flow. The bottom of diagonal curb ramps shall have a clear space 48 inches (1220 mm) minimum outside active traffic lanes of the roadway. Diagonal curb ramps provided at marked crossings shall provide the 48 inches (1220 mm) minimum clear space within the markings. Diagonal curb ramps with flared sides shall have a segment of curb 24 inches (610 mm) long minimum located on each side of the curb ramp and within the marked crossing. 82 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 TECHNICAL CHAPTER 4: ACCESSIBLE ROUTES FIGURE 406.6 DIAGONAL OR CORNER TYPE CURB RAMPS 406.7 Islands. Raised islands in crossings shall be cut through level with the street or have curb ramps at both sides. Each curb ramp shall have a level area 48 inches (1220 mm) long minimum by 36 inches (915 mm) wide minimum at the top of the curb ramp in the part of the island intersected by the crossings. Each 48 inch (1220 mm) minimum by 36 inch (915 mm) minimum area shall be oriented so that the 48 inch (1220 mm) minimum length is in the direction of the running slope of the curb ramp it serves. The 48 inch (1220 mm) minimum by 36 inch (915 mm) minimum areas and the accessible route shall be permitted to overlap. FIGURE 406.7 ISLANDS IN CROSSINGS 406.8 Detectable Warnings. Curb ramps subject to Department of Transportation regulation 49 CFR 37.21 shall have a detectable warning complying with 705. The detectable warning shall extend the full width of the curb ramp (exclusive of flared sides) and shall extend either the full depth of the curb ramp or 24 inches (610 mm) deep minimum measured from the back of the curb on the ramp surface. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 83 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 4: ACCESSIBLE ROUTES TECHNICAL FIGURE 406.8 DETECTABLE WARNINGS AT CURB RAMPS SUBJECT TO DOT REGULATION 49 CFR 37.21 407 ELEVATORS 407.1 General. Elevators shall comply with 407 and with ASME A17.1 (incorporated by reference, see “Referenced Standards” in Chapter 1). They shall be passenger elevators as classified by ASME A17.1. Elevator operation shall be automatic. Advisory 407.1 General. The ADA and other Federal civil rights laws require that accessible features be maintained in working order so that they are accessible to and usable by those people they are intended to benefit. Building owners should note that the ASME Safety Code for Elevators and Escalators requires routine maintenance and inspections. Isolated or temporary interruptions in service due to maintenance or repairs may be unavoidable; however, failure to take prompt action to effect repairs could constitute a violation of Federal laws and these requirements. 407.2 Elevator Landing Requirements. Elevator landings shall comply with 407.2. 407.2.1 Call Controls. Where elevator call buttons or keypads are provided, they shall comply with 407.2.1 and 309.4. Call buttons shall be raised or flush. EXCEPTION: Existing elevators shall be permitted to have recessed call buttons. 407.2.1.1 Height. Call buttons and keypads shall be located within one of the reach ranges specified in 308, measured to the centerline of the highest operable part. EXCEPTION: Existing call buttons and existing keypads shall be permitted to be located at 54 inches (1370 mm) maximum above the finish floor, measured to the centerline of the highest operable part. 407.2.1.2 Size. Call buttons shall be 3/4 inch (19 mm) minimum in the smallest dimension. EXCEPTION: Existing elevator call buttons shall not be required to comply with 407.2.1.2. 407.2.1.3 Clear Floor or Ground Space. A clear floor or ground space complying with 305 shall be provided at call controls. Advisory 407.2.1.3 Clear Floor or Ground Space. The clear floor or ground space required at elevator call buttons must remain free of obstructions including ashtrays, plants, and other decorative elements that prevent wheelchair users and others from reaching the call buttons. The height of the clear floor or ground space is considered to be a volume from the floor to 80 inches (2030 mm) above the floor. Recessed ashtrays should not be placed near elevator call buttons so that persons who are blind or visually impaired do not inadvertently contact them or their contents as they reach for the call buttons. 84 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 TECHNICAL CHAPTER 4: ACCESSIBLE ROUTES 407.2.1.4 Location. The call button that designates the up direction shall be located above the call button that designates the down direction. EXCEPTION: Destination-oriented elevators shall not be required to comply with 407.2.1.4. Advisory 407.2.1.4 Location Exception. A destination-oriented elevator system provides lobby controls enabling passengers to select floor stops, lobby indicators designating which elevator to use, and a car indicator designating the floors at which the car will stop. Responding cars are programmed for maximum efficiency by reducing the number of stops any passenger experiences. 407.2.1.5 Signals. Call buttons shall have visible signals to indicate when each call is registered and when each call is answered. EXCEPTIONS: 1. Destination-oriented elevators shall not be required to comply with 407.2.1.5 provided that visible and audible signals complying with 407.2.2 indicating which elevator car to enter are provided. 2. Existing elevators shall not be required to comply with 407.2.1.5. 407.2.1.6 Keypads. Where keypads are provided, keypads shall be in a standard telephone keypad arrangement and shall comply with 407.4.7.2. 407.2.2 Hall Signals. Hall signals, including in-car signals, shall comply with 407.2.2. 407.2.2.1 Visible and Audible Signals. A visible and audible signal shall be provided at each hoistway entrance to indicate which car is answering a call and the car’s direction of travel. Where in-car signals are provided, they shall be visible from the floor area adjacent to the hall call buttons. EXCEPTIONS: 1. Visible and audible signals shall not be required at each destination-oriented elevator where a visible and audible signal complying with 407.2.2 is provided indicating the elevator car designation information. 2. In existing elevators, a signal indicating the direction of car travel shall not be required. 407.2.2.2 Visible Signals. Visible signal fixtures shall be centered at 72 inches (1830 mm) minimum above the finish floor or ground. The visible signal elements shall be 21/2 inches (64 mm) minimum measured along the vertical centerline of the element. Signals shall be visible from the floor area adjacent to the hall call button. EXCEPTIONS: 1. Destination-oriented elevators shall be permitted to have signals visible from the floor area adjacent to the hoistway entrance. 2. Existing elevators shall not be required to comply with 407.2.2.2. FIGURE 407.2.2.2 VISIBLE HALL SIGNALS FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 85 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 4: ACCESSIBLE ROUTES TECHNICAL 407.2.2.3 Audible Signals. Audible signals shall sound once for the up direction and twice for the down direction, or shall have verbal annunciators that indicate the direction of elevator car travel. Audible signals shall have a frequency of 1500 Hz maximum. Verbal annunciators shall have a frequency of 300 Hz minimum and 3000 Hz maximum. The audible signal and verbal annunciator shall be 10 dB minimum above ambient, but shall not exceed 80 dB, measured at the hall call button. EXCEPTIONS: 1. Destination-oriented elevators shall not be required to comply with 407.2.2.3 provided that the audible tone and verbal announcement is the same as those given at the call button or call button keypad. 2. Existing elevators shall not be required to comply with the requirements for frequency and dB range of audible signals. 407.2.2.4 Differentiation. Each destination-oriented elevator in a bank of elevators shall have audible and visible means for differentiation. 407.2.3 Hoistway Signs. Signs at elevator hoistways shall comply with 407.2.3. 407.2.3.1 Floor Designation. Floor designations complying with 703.2 and 703.4.1 shall be provided on both jambs of elevator hoistway entrances. Floor designations shall be provided in both tactile characters and braille. Tactile characters shall be 2 inches (51 mm) high minimum. A tactile star shall be provided on both jambs at the main entry level. FIGURE 407.2.3.1 FLOOR DESIGNATIONS ON JAMBS OF ELEVATOR HOISTWAY ENTRANCES 407.2.3.2 Car Designations. Destination-oriented elevators shall provide tactile car identification complying with 703.2 on both jambs of the hoistway immediately below the floor designation. Car designations shall be provided in both tactile characters and braille. Tactile characters shall be 2 inches (51 mm) high minimum. FIGURE 407.2.3.2 CAR DESIGNATIONS ON JAMBS OF DESTINATION-ORIENTATED ELEVATOR HOISTWAY ENTRANCES 407.3 Elevator Door Requirements. Hoistway and car doors shall comply with 407.3. 407.3.1 Type. Elevator doors shall be the horizontal sliding type. Car gates shall be prohibited. 407.3.2 Operation. Elevator hoistway and car doors shall open and close automatically. EXCEPTION: Existing manually operated hoistway swing doors shall be permitted provided that they comply with 404.2.3 and 404.2.9. Car door closing shall not be initiated until the hoistway door is closed. 86 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 TECHNICAL CHAPTER 4: ACCESSIBLE ROUTES 407.3.3 Reopening Device. Elevator doors shall be provided with a reopening device complying with 407.3.3 that shall stop and reopen a car door and hoistway door automatically if the door becomes obstructed by an object or person. EXCEPTION: Existing elevators with manually operated doors shall not be required to comply with 407.3.3. 407.3.3.1 Height. The device shall be activated by sensing an obstruction passing through the opening at 5 inches (125 mm) nominal and 29 inches (735 mm) nominal above the finish floor. 407.3.3.2 Contact. The device shall not require physical contact to be activated, although contact is permitted to occur before the door reverses. 407.3.3.3 Duration. Door reopening devices shall remain effective for 20 seconds minimum. 407.3.4 Door and Signal Timing. The minimum acceptable time from notification that a car is answering a call or notification of the car assigned at the means for the entry of destination information until the doors of that car start to close shall be calculated from the following equation: T = D/(1.5 ft/s) or T = D/(455 mm/s) = 5 seconds minimum where T equals the total time in seconds and D equals the distance (in feet or millimeters) from the point in the lobby or corridor 60 inches (1525 mm) directly in front of the farthest call button controlling that car to the centerline of its hoistway door. EXCEPTIONS: 1. For cars with in-car lanterns, T shall be permitted to begin when the signal is visible from the point 60 inches (1525 mm) directly in front of the farthest hall call button and the audible signal is sounded. 2. Destination-oriented elevators shall not be required to comply with 407.3.4. 407.3.5 Door Delay. Elevator doors shall remain fully open in response to a car call for 3 seconds minimum. 407.3.6 Width. The width of elevator doors shall comply with Table 407.4.1. EXCEPTION: In existing elevators, a power-operated car door complying with 404.2.3 shall be permitted. 407.4 Elevator Car Requirements. Elevator cars shall comply with 407.4. 407.4.1 Car Dimensions. Inside dimensions of elevator cars and clear width of elevator doors shall comply with Table 407.4.1. EXCEPTION: Existing elevator car configurations that provide a clear floor area of 16 square feet (1.5 m2) minimum and also provide an inside clear depth 54 inches (1370 mm) minimum and a clear width 36 inches (915 mm) minimum shall be permitted. TABLE 407.4.1 ELEVATOR CAR DIMENSIONS Minimum Dimensions Door Location Centered Side (off-centered) Any Any Door Clear Width Inside Car, Side to Side Inside Car, Back Wall to Front Return Inside Car, Back Wall to Inside Face of Door 42 inches (1065 mm) 36 inches (915 mm)1 36 inches (915 mm)1 36 inches (915 mm)1 80 inches (2030 mm) 68 inches (1725 mm) 54 inches (1370 mm) 60 inches (1525 mm)2 51 inches (1295 mm) 51 inches (1295 mm) 80 inches (2030 mm) 60 inches (1525 mm)2 54 inches (1370 mm) 54 inches (1370 mm) 80 inches (2030 mm) 60 inches (1525 mm)2 1. A tolerance of minus 5/8 -inch (16 mm) is permitted. 2. Other car configurations that provide a turning space complying with 304 with the door closed shall be permitted. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 87 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 4: ACCESSIBLE ROUTES TECHNICAL FIGURE 407.4.1 ELEVATOR CAR DIMENSIONS (continued) 88 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 TECHNICAL CHAPTER 4: ACCESSIBLE ROUTES FIGURE 407.4.1—CONTINUED ELEVATOR CAR DIMENSIONS 407.4.2 Floor Surfaces. Floor surfaces in elevator cars shall comply with 302 and 303. 407.4.3 Platform to Hoistway Clearance. The clearance between the car platform sill and the edge of any hoistway landing shall be 11/4 inch (32 mm) maximum. 407.4.4 Leveling. Each car shall be equipped with a self-leveling feature that will automatically bring and maintain the car at floor landings within a tolerance of 1/2 inch (13 mm) under rated loading to zero loading conditions. 407.4.5 Illumination. The level of illumination at the car controls, platform, car threshold and car landing sill shall be 5 foot candles (54 lux) minimum. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 89 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 4: ACCESSIBLE ROUTES TECHNICAL 407.4.6 Elevator Car Controls. Where provided, elevator car controls shall comply with 407.4.6 and 309.4. EXCEPTION: In existing elevators, where a new car operating panel complying with 407.4.6 is provided, existing car operating panels shall not be required to comply with 407.4.6. 407.4.6.1 Location. Controls shall be located within one of the reach ranges specified in 308. EXCEPTIONS: 1. Where the elevator panel serves more than 16 openings and a parallel approach is provided, buttons with floor designations shall be permitted to be 54 inches (1370 mm) maximum above the finish floor. 2. In existing elevators, car control buttons with floor designations shall be permitted to be located 54 inches (1370 mm) maximum above the finish floor where a parallel approach is provided. 407.4.6.2 Buttons. Car control buttons with floor designations shall comply with 407.4.6.2 and shall be raised or flush. EXCEPTION: In existing elevators, buttons shall be permitted to be recessed. 407.4.6.2.1 Size. Buttons shall be 3/4 inch (19 mm) minimum in their smallest dimension. 407.4.6.2.2 Arrangement. Buttons shall be arranged with numbers in ascending order. When two or more columns of buttons are provided they shall read from left to right. 407.4.6.3 Keypads. Car control keypads shall be in a standard telephone keypad arrangement and shall comply with 407.4.7.2. 407.4.6.4 Emergency Controls. Emergency controls shall comply with 407.4.6.4. 407.4.6.4.1 Height. Emergency control buttons shall have their centerlines 35 inches (890 mm) minimum above the finish floor. 407.4.6.4.2 Location. Emergency controls, including the emergency alarm, shall be grouped at the bottom of the panel. 407.4.7 Designations and Indicators of Car Controls. Designations and indicators of car controls shall comply with 407.4.7. EXCEPTION: In existing elevators, where a new car operating panel complying with 407.4.7 is provided, existing car operating panels shall not be required to comply with 407.4.7. 407.4.7.1 Buttons. Car control buttons shall comply with 407.4.7.1. 407.4.7.1.1 Type. Control buttons shall be identified by tactile characters complying with 703.2. 407.4.7.1.2 Location. Raised character and braille designations shall be placed immediately to the left of the control button to which the designations apply. EXCEPTION: Where space on an existing car operating panel precludes tactile markings to the left of the controls, markings shall be placed as near to the control as possible. 90 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 TECHNICAL CHAPTER 4: ACCESSIBLE ROUTES 407.4.7.1.3 Symbols. The control button for the emergency stop, alarm, door open, door close, main entry floor, and phone, shall be identified with tactile symbols as shown in Table 407.4.7.1.3. TABLE 407.4.7.1.3 ELEVATOR CONTROL BUTTON IDENTIFICATION 407.4.7.1.4 Visible Indicators. Buttons with floor designations shall be provided with visible indicators to show that a call has been registered. The visible indication shall extinguish when the car arrives at the designated floor. 407.4.7.2 Keypads. Keypads shall be identified by characters complying with 703.5 and shall be centered on the corresponding keypad button. The number five key shall have a single raised dot. The dot shall be 0.118 inch (3 mm) to 0.120 inch (3.05 mm) base diameter and in other aspects comply with Table 703.3.1. 407.4.8 Car Position Indicators. Audible and visible car position indicators shall be provided in elevator cars. 407.4.8.1 Visible Indicators. Visible indicators shall comply with 407.4.8.1. 407.4.8.1.1 Size. Characters shall be 1/2 inch (13 mm) high minimum. 407.4.8.1.2 Location. Indicators shall be located above the car control panel or above the door. 407.4.8.1.3 Floor Arrival. As the car passes a floor and when a car stops at a floor served by the elevator, the corresponding character shall illuminate. EXCEPTION: Destination-oriented elevators shall not be required to comply with 407.4.8.1.3 provided that the visible indicators extinguish when the call has been answered. 407.4.8.1.4 Destination Indicator. In destination-oriented elevators, a display shall be provided in the car with visible indicators to show car destinations. 407.4.8.2 Audible Indicators. Audible indicators shall comply with 407.4.8.2. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 91 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 4: ACCESSIBLE ROUTES TECHNICAL 407.4.8.2.1 Signal Type. The signal shall be an automatic verbal annunciator which announces the floor at which the car is about to stop. EXCEPTION: For elevators other than destination-oriented elevators that have a rated speed of 200 feet per minute (1 m/s) or less, a non-verbal audible signal with a frequency of 1500 Hz maximum which sounds as the car passes or is about to stop at a floor served by the elevator shall be permitted. 407.4.8.2.2 Signal Level. The verbal annunciator shall be 10 dB minimum above ambient, but shall not exceed 80 dB, measured at the annunciator. 407.4.8.2.3 Frequency. The verbal annunciator shall have a frequency of 300 Hz minimum to 3000 Hz maximum. 407.4.9 Emergency Communication. Emergency two-way communication systems shall comply with 308. Tactile symbols and characters shall be provided adjacent to the device and shall comply with 703.2. 408 LIMITED-USE/LIMITED-APPLICATION ELEVATORS 408.1 General. Limited-use/limited-application elevators shall comply with 408 and with ASME A17.1 (incorporated by reference, see “Referenced Standards” in Chapter 1). They shall be passenger elevators as classified by ASME A17.1. Elevator operation shall be automatic. 408.2 Elevator Landings. Landings serving limited-use/limited-application elevators shall comply with 408.2. 408.2.1 Call Buttons. Elevator call buttons and keypads shall comply with 407.2.1. 408.2.2 Hall Signals. Hall signals shall comply with 407.2.2. 408.2.3 Hoistway Signs. Signs at elevator hoistways shall comply with 407.2.3.1. 408.3 Elevator Doors. Elevator hoistway doors shall comply with 408.3. 408.3.1 Sliding Doors. Sliding hoistway and car doors shall comply with 407.3.1 through 407.3.3 and 408.4.1. 408.3.2 Swinging Doors. Swinging hoistway doors shall open and close automatically and shall comply with 404, 407.3.2 and 408.3.2. 408.3.2.1 Power Operation. Swinging doors shall be power-operated and shall comply with ANSI/BHMA A156.19 (1997 or 2002 edition) (incorporated by reference, see “Referenced Standards” in Chapter 1). 408.3.2.2 Duration. Power-operated swinging doors shall remain open for 20 seconds minimum when activated. 408.4 Elevator Cars. Elevator cars shall comply with 408.4. 408.4.1 Car Dimensions and Doors. Elevator cars shall provide a clear width 42 inches (1065 mm) minimum and a clear depth 54 inches (1370 mm) minimum. Car doors shall be positioned at the narrow ends of cars and shall provide 32 inches (815 mm) minimum clear width. EXCEPTIONS: 1. Cars that provide a clear width 51 inches (1295 mm) minimum shall be permitted to provide a clear depth 51 inches (1295 mm) minimum provided that car doors provide a clear opening 36 inches (915 mm) wide minimum. 2. Existing elevator cars shall be permitted to provide a clear width 36 inches (915 mm) minimum, clear depth 54 inches (1370 mm) minimum, and a net clear platform area 15 square feet (1.4 m2) minimum. 92 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 TECHNICAL CHAPTER 4: ACCESSIBLE ROUTES FIGURE 408.4.1 LIMITED-USE/LIMITED-APPLICATION (LULA) ELEVATOR CAR DIMENSIONS 408.4.2 Floor Surfaces. Floor surfaces in elevator cars shall comply with 302 and 303. 408.4.3 Platform to Hoistway Clearance. The platform to hoistway clearance shall comply with 407.4.3. 408.4.4 Leveling. Elevator car leveling shall comply with 407.4.4. 408.4.5 Illumination. Elevator car illumination shall comply with 407.4.5. 408.4.6 Car Controls. Elevator car controls shall comply with 407.4.6. Control panels shall be centered on a side wall. 408.4.7 Designations and Indicators of Car Controls. Designations and indicators of car controls shall comply with 407.4.7. 408.4.8 Emergency Communications. Car emergency signaling devices complying with 407.4.9 shall be provided. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 93 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 4: ACCESSIBLE ROUTES TECHNICAL 409 PRIVATE RESIDENCE ELEVATORS 409.1 General. Private residence elevators that are provided within a residential dwelling unit required to provide mobility features complying with 809.2 through 809.4 shall comply with 409 and with ASME A17.1 (incorporated by reference, see “Referenced Standards” in Chapter 1). They shall be passenger elevators as classified by ASME A17.1. Elevator operation shall be automatic. 409.2 Call Buttons. Call buttons shall be 3/4 inch (19 mm) minimum in the smallest dimension and shall comply with 309. 409.3 Elevator Doors. Hoistway doors, car doors, and car gates shall comply with 409.3 and 404. EXCEPTION: Doors shall not be required to comply with the maneuvering clearance requirements in 404.2.4.1 for approaches to the push side of swinging doors. 409.3.1 Power Operation. Elevator car and hoistway doors and gates shall be power operated and shall comply with ANSI/BHMA A156.19 (1997 or 2002 edition) (incorporated by reference, see “Referenced Standards” in Chapter 1). Power operated doors and gates shall remain open for 20 seconds minimum when activated. EXCEPTION: In elevator cars with more than one opening, hoistway doors and gates shall be permitted to be of the manual-open, self-close type. 409.3.2 Location. Elevator car doors or gates shall be positioned at the narrow end of the clear floor spaces required by 409.4.1. 409.4 Elevator Cars. Private residence elevator cars shall comply with 409.4. 409.4.1 Inside Dimensions of Elevator Cars. Elevator cars shall provide a clear floor space of 36 inches (915 mm) minimum by 48 inches (1220 mm) minimum and shall comply with 305. 409.4.2 Floor Surfaces. Floor surfaces in elevator cars shall comply with 302 and 303. 409.4.3 Platform to Hoistway Clearance. The clearance between the car platform and the edge of any landing sill shall be 11/2 inch (38 mm) maximum. 409.4.4 Leveling. Each car shall automatically stop at a floor landing within a tolerance of 1/2 inch (13 mm) under rated loading to zero loading conditions. 409.4.5 Illumination Levels. Elevator car illumination shall comply with 407.4.5. 409.4.6 Car Controls. Elevator car control buttons shall comply with 409.4.6, 309.3, 309.4, and shall be raised or flush. 409.4.6.1 Size. Control buttons shall be 3/4 inch (19 mm) minimum in their smallest dimension. 409.4.6.2 Location. Control panels shall be on a side wall, 12 inches (305 mm) minimum from any adjacent wall. 94 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 TECHNICAL CHAPTER 4: ACCESSIBLE ROUTES FIGURE 409.4.6.2 LOCATION OF PRIVATE RESIDENCE ELEVATOR CONTROL PANEL 409.4.7 Emergency Communications. Emergency two-way communication systems shall comply with 409.4.7. 409.4.7.1 Type. A telephone and emergency signal device shall be provided in the car. 409.4.7.2 Operable Parts. The telephone and emergency signaling device shall comply with 309.3 and 309.4. 409.4.7.3 Compartment. If the telephone or device is in a closed compartment, the compartment door hardware shall comply with 309. 409.4.7.4 Cord. The telephone cord shall be 29 inches (735 mm) long minimum. 410 PLATFORM LIFTS 410.1 General. Platform lifts shall comply with ASME A18.1 (1999 edition or 2003 edition) (incorporated by reference, see “Referenced Standards” in Chapter 1). Platform lifts shall not be attendant-operated and shall provide unassisted entry and exit from the lift. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 95 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 4: ACCESSIBLE ROUTES TECHNICAL Advisory 410.1 General. Inclined stairway chairlifts and inclined and vertical platform lifts are available for short-distance vertical transportation. Because an accessible route requires an 80 inch (2030 mm) vertical clearance, care should be taken in selecting lifts as they may not be equally suitable for use by people using wheelchairs and people standing. If a lift does not provide 80 inch (2030 mm) vertical clearance, it cannot be considered part of an accessible route in new construction. The ADA and other Federal civil rights laws require that accessible features be maintained in working order so that they are accessible to and usable by those people they are intended to benefit. Building owners are reminded that the ASME A18 Safety Standard for Platform Lifts and Stairway Chairlifts requires routine maintenance and inspections. Isolated or temporary interruptions in service due to maintenance or repairs may be unavoidable; however, failure to take prompt action to effect repairs could constitute a violation of Federal laws and these requirements. 410.2 Floor Surfaces. Floor surfaces in platform lifts shall comply with 302 and 303. 410.3 Clear Floor Space. Clear floor space in platform lifts shall comply with 305. 410.4 Platform to Runway Clearance. The clearance between the platform sill and the edge of any runway landing shall be 1 inch (32 mm) maximum. 410.5 Operable Parts. Controls for platform lifts shall comply with 309. 410.6 Doors and Gates. Platform lifts shall have low-energy power-operated doors or gates complying with 404.3. Doors shall remain open for 20 seconds minimum. End doors and gates shall provide a clear width 32 inches (815 mm) minimum. Side doors and gates shall provide a clear width 42 inches (1065 mm) minimum. EXCEPTION: Platform lifts serving two landings maximum and having doors or gates on opposite sides shall be permitted to have self-closing manual doors or gates. FIGURE 410.6 PLATFORM LIFT DOORS AND GATES 96 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 5: GENERAL SITE AND BUILDING ELEMENTS 501 GENERAL 501.1 Scope. The provisions of Chapter 5 shall apply where required by Chapter 2 or where referenced by a requirement in this code. 502 PARKING SPACES 502.1 General. Car and van parking spaces shall comply with 502. Where parking spaces are marked with lines, width measurements of parking spaces and access aisles shall be made from the centerline of the markings. EXCEPTION: Where parking spaces or access aisles are not adjacent to another parking space or access aisle, measurements shall be permitted to include the full width of the line defining the parking space or access aisle. 502.2 Vehicle Spaces. Each parking space must be at least 12 feet (3658 mm) wide, shall be marked to define the width, and shall have an adjacent access aisle complying with 502.3. See section 406.5 curb ramp location. EXCEPTION: For on-street parallel parking spaces and theme parks or an entertainment complex in which are provided continuous attendant services or designated lots for parking by persons who have disabilities: car parking spaces shall be permitted to be 96 inches (2440 mm) wide minimum; van parking spaces shall be permitted to be 96 inches (2440 mm) wide minimum where the access aisle is 96 inches (2440) wide minimum and shall be designated “van accessible”; alternatively, van parking spaces shall be permitted to be 132 inches (3350 mm) wide minimum where the access aisle is 60 inches (1525 mm) wide minimum and shall be designated “van accessible.” Advisory 502.2 Vehicle Spaces. Pursuant to s.553.512, F.S., Florida requirements, except s.553.041(c)1 parking space and access aisle width, may be waived down to the requirements of the ADA Standards for Accessible Design. No waivers are required for on-street parallel parking spaces and theme parks or an entertainment complex in which are provided continuous attendant services or designated lots for parking by persons who have disabilities pursuant to ss.553.041(5)(c)3. and (d), F.S., and the Exception to 502.2. FIGURE 502.2 VEHICLE PARKING SPACES 502.2.1 On-street parallel parking. Spaces must comply with sections 208 and 502 of the ADA Standards for Accessible Design. Curbs adjacent to such spaces must be of a height that does not interfere with the opening and closing of motor vehicle doors. 502.3 Access Aisle. Access aisles serving parking spaces shall comply with 502.3. Access aisles shall adjoin an accessible route. Two parking spaces shall be permitted to share a common access aisle. Parking access aisles must be part of an accessible route to the building or facility entrance. Access aisles must be placed adjacent to accessible parking spaces. All spaces must be located on an accessible route that is at least 44 inches (1118 mm) wide so that users are not compelled to walk or wheel behind parked vehicles except behind his or her own vehicle. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 97 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 5: GENERAL SITE AND BUILDING ELEMENTS TECHNICAL EXCEPTION: Access aisles are not required for on-street parallel parking. Advisory 502.3 Access Aisle. Accessible routes must connect parking spaces to accessible entrances. In parking facilities where the accessible route must cross vehicular traffic lanes, marked crossings enhance pedestrian safety, particularly for people using wheelchairs and other mobility aids. Florida law, s.553.5041(5)(a), F.S., requires placement of accessible routes such that persons with disabilities are not compelled to walk or wheel behind parked vehicles other than their own vehicle. Florida law, s.553.5041(5)(d), F.S., allows on-street accessible parking to not have an access aisle. FIGURE 502.3 PARKING SPACE ACCESS AISLE 502.3.1 Width. Access aisles serving car and van parking spaces shall be 60 inches (1525 mm) wide minimum. 502.3.2 Length. Access aisles shall extend the full length of the parking spaces they serve. 502.3.3 Marking. Access aisles shall be marked so as to discourage parking in them. The access aisle must be striped diagonally to designate it as a no-parking zone. Advisory 502.3.3 Marking. The method and color of marking are not specified by these requirements but may be addressed by State or local laws or regulations. Because these requirements permit the van access aisle to be as wide as a parking space, it is important that the aisle be clearly marked. Florida law, s.553.5041(5)(c)1., requires diagonal striping of access aisles. 502.3.4 Location. Access aisles shall not overlap the vehicular way. Access aisles shall be permitted to be placed on either side of the parking space except for angled van parking spaces which shall have access aisles located on the passenger side of the parking spaces. Advisory 502.3.4 Location. Wheelchair lifts typically are installed on the passenger side of vans. Many drivers, especially those who operate vans, find it more difficult to back into parking spaces than to back out into comparatively unrestricted vehicular lanes. For this reason, where a van and car share an access aisle, consider locating the van space so that the access aisle is on the passenger side of the van space. 98 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 TECHNICAL CHAPTER 5: GENERAL SITE AND BUILDING ELEMENTS 502.4 Floor or Ground Surfaces. Parking spaces and access aisles serving them shall comply with 302. Access aisles shall be at the same level as the parking spaces they serve. Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted. Advisory 502.4 Floor or Ground Surfaces. Access aisles are required to be nearly level in all directions to provide a surface for wheelchair transfer to and from vehicles. The exception allows sufficient slope for drainage. Built-up curb ramps are not permitted to project into access aisles and parking spaces because they would create slopes greater than 1:48. 502.5 Vertical Clearance. Parking spaces for vans and access aisles and vehicular routes serving them shall provide a vertical clearance of 98 inches (2490 mm) minimum. Every nonresidential structure built on or after January 1, 1991, which is designed to use covered or underground parking as the primary available parking space shall design the covered or underground parking facility to maintain a minimum height for the portion of the street-accessible level of the parking facility directly over van-accessible parking spaces and for providing ingress and egress to such parking spaces of at least 8 feet 2 inches (2489 mm). Signs shall be posted to warn operators of handicap-equipped vans that they cannot pass beyond a certain point due to height limitations. If compliance with this minimum height clearance requirement will cause the structure to exceed local height limitations imposed by local zoning, planning, or fire ordinances, or will result in the imposition of any additional requirements of such ordinances, the structure may exceed the height limitation specified in those particular codes as necessary to comply with the requirements of this section and is exempt from such additional requirements. Structures for which the plans were sealed by an architect prior to January 1, 1991, are exempt from this section. Advisory 502.5 Vertical Clearance. Signs provided at entrances to parking facilities informing drivers of clearances and the location of van accessible parking spaces can provide useful customer assistance. Florida law, s.553.511, F.S., requires signs be posted that will warn handicapped-equipped van operators of height limitations so they will not pass beyond a point where the van cannot be maneuvered. Florida law also preempts local government height restriction ordinances that would prohibit compliance with the minimum height requirements of this section. Also, any local or state law or regulation that prohibits a covered entity from complying with requirements of the ADA may render such jurisdiction in violation of the ADA. 502.6 Identification. Parking space identification signs shall include the International Symbol of Accessibility complying with 703.7.2.1. Signs identifying van parking spaces when required by 502.2 shall contain the designation “van accessible.” 502.6.1 Each such parking space must be striped in a manner that is consistent with the standards of the controlling jurisdiction for other spaces and prominently outlined with blue paint, and must be repainted when necessary, to be clearly distinguishable as a parking space designated for persons who have disabilities. The space must be posted with a permanent above-grade sign of a color and design approved by the Department of Transportation, which is placed on or at least 60 inches (1525 mm) above the finished floor or ground surface measured to the bottom of the sign and which bears the international symbol of accessibility and the caption “PARKING BY DISABLED PERMIT ONLY.” Such a sign, erected after October 1, 1996, must indicate the penalty for illegal use of the space. Any provision of this section to the contrary notwithstanding, in a theme park or an entertainment complex as defined in Section 509.013 in which accessible parking is located in designated lots or areas, the signage indicating the lot as reserved for accessible parking may be located at the entrances to the lot in lieu of a sign at each parking place. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 99 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 5: GENERAL SITE AND BUILDING ELEMENTS TECHNICAL Advisory 502.6 Identification. The required “van accessible” designation is intended to be informative, not restrictive, in identifying those spaces that are better suited for van use. Enforcement of motor vehicle laws, including parking privileges, is a local matter. Parking space and access aisle configurations required for all accessible parking by Florida law, s.553.5041, F.S., meet the van accessible space requirements of the ADA Standards for Accessible Design. Therefore, no accessible space is more suitable than any other accessible space for “van accessible” parking. Florida law only requires “van accessible” parking signs in parking structures where van parking may be limited to the first level accessible spaces. Florida accessible parking signs must include indication of the penalty for illegal parking in addition to the accessible parking symbol required by the ADA Standards for Accessible Design. 502.7 Relationship to Accessible Routes. Parking spaces and access aisles shall be designed so that cars and vans, when parked, cannot obstruct the required clear width of adjacent accessible routes. Advisory 502.7 Relationship to Accessible Routes. Wheel stops are an effective way to prevent vehicle overhangs from reducing the clear width of accessible routes. 503 PASSENGER LOADING ZONES 503.1 General. Passenger loading zones shall comply with 503. 503.2 Vehicle Pull-Up Space. Passenger loading zones shall provide a vehicular pull-up space 96 inches (2440 mm) wide minimum and 20 feet (6100 mm) long minimum. 503.3 Access Aisle. Passenger loading zones shall provide access aisles complying with 503 adjacent to the vehicle pull-up space. Access aisles shall adjoin an accessible route and shall not overlap the vehicular way. FIGURE 503.3 PASSENGER LOADING ZONE ACCESS AISLE 503.3.1 Width. Access aisles serving vehicle pull-up spaces shall be 60 inches (1525 mm) wide minimum. 503.3.2 Length. Access aisles shall extend the full length of the vehicle pull-up spaces they serve. 503.3.3 Marking. Access aisles shall be marked so as to discourage parking in them. 503.4 Floor and Ground Surfaces. Vehicle pull-up spaces and access aisles serving them shall comply with 302. Access aisles shall be at the same level as the vehicle pull-up space they serve. Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted. 100 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 TECHNICAL CHAPTER 5: GENERAL SITE AND BUILDING ELEMENTS 503.5 Vertical Clearance. Vehicle pull-up spaces, access aisles serving them, and a vehicular route from an entrance to the passenger loading zone, and from the passenger loading zone to a vehicular exit shall provide a vertical clearance of 114 inches (2895 mm) minimum. 504 STAIRWAYS 504.1 General. Stairs shall comply with 504. 504.2 Treads and Risers. All steps on a flight of stairs shall have uniform riser heights and uniform tread depths. Risers shall be 4 inches (100 mm) high minimum and 7 inches (180 mm) high maximum. Treads shall be 11 inches (280 mm) deep minimum. 504.3 Open Risers. Open risers are not permitted. 504.4 Tread Surface. Stair treads shall comply with 302. Changes in level are not permitted. EXCEPTION: Treads shall be permitted to have a slope not steeper than 1:48. Advisory 504.4 Tread Surface. Consider providing visual contrast on tread nosings, or at the leading edges of treads without nosings, so that stair treads are more visible for people with low vision. 504.5 Nosings. The radius of curvature at the leading edge of the tread shall be 1/2 inch (13 mm) maximum. Nosings that project beyond risers shall have the underside of the leading edge curved or beveled. Risers shall be permitted to slope under the tread at an angle of 30 degrees maximum from vertical. The permitted projection of the nosing shall extend 11/2 inches (38 mm) maximum over the tread below. FIGURE 504.5 STAIR NOSINGS 504.6 Handrails. Stairs shall have handrails complying with 505. 504.7 Wet Conditions. Stair treads and landings subject to wet conditions shall be designed to prevent the accumulation of water. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 101 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 5: GENERAL SITE AND BUILDING ELEMENTS TECHNICAL 505 HANDRAILS 505.1 General. Handrails provided along walking surfaces complying with 403, required at ramps complying with 405, and required at stairs complying with 504 shall comply with 505. Advisory 505.1 General. Handrails are required on ramp runs with a rise greater than 6 inches (150 mm) (see 405.8) and on certain stairways (see 504). Handrails are not required on walking surfaces with running slopes less than 1:20. However, handrails are required to comply with 505 when they are provided on walking surfaces with running slopes less than 1:20 (see 403.6). Sections 505.2, 505.3, and 505.10 do not apply to handrails provided on walking surfaces with running slopes less than 1:20 as these sections only reference requirements for ramps and stairs. 505.2 Where Required. Handrails shall be provided on both sides of stairs and ramps. EXCEPTION: In assembly areas, handrails shall not be required on both sides of aisle ramps where a handrail is provided at either side or within the aisle width. 505.3 Continuity. Handrails shall be continuous within the full length of each stair flight or ramp run. Inside handrails on switchback or dogleg stairs and ramps shall be continuous between flights or runs. EXCEPTION: In assembly areas, handrails on ramps shall not be required to be continuous in aisles serving seating. 505.4 Height. Top of gripping surfaces of handrails shall be 34 inches (865 mm) minimum and 38 inches (965 mm) maximum vertically above walking surfaces, stair nosings, and ramp surfaces. Handrails shall be at a consistent height above walking surfaces, stair nosings, and ramp surfaces. Advisory 505.4 Height. The requirements for stair and ramp handrails in this code are for adults. When children are the principal users in a building or facility (e.g., elementary schools), a second set of handrails at an appropriate height can assist them and aid in preventing accidents. A maximum height of 28 inches (710 mm) measured to the top of the gripping surface from the ramp surface or stair nosing is recommended for handrails designed for children. Sufficient vertical clearance between upper and lower handrails, 9 inches (230 mm) minimum, should be provided to help prevent entrapment. FIGURE 505.4 HANDRAIL HEIGHT 102 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 TECHNICAL CHAPTER 5: GENERAL SITE AND BUILDING ELEMENTS 505.5 Clearance. Clearance between handrail gripping surfaces and adjacent surfaces shall be 11/2 inches (38 mm) minimum. FIGURE 505.5 HANDRAIL CLEARANCE 505.6 Gripping Surface. Handrail gripping surfaces shall be continuous along their length and shall not be obstructed along their tops or sides. The bottoms of handrail gripping surfaces shall not be obstructed for more than 20 percent of their length. Where provided, horizontal projections shall occur 11/2 inches (38 mm) minimum below the bottom of the handrail gripping surface. EXCEPTIONS: 1. Where handrails are provided along walking surfaces with slopes not steeper than 1:20, the bottoms of handrail gripping surfaces shall be permitted to be obstructed along their entire length where they are integral to crash rails or bumper guards. 2. The distance between horizontal projections and the bottom of the gripping surface shall be permitted to be reduced by 1/8 inch (3.2 mm) for each 1/2 inch (13 mm) of additional handrail perimeter dimension that exceeds 4 inches (100 mm). Advisory 505.6 Gripping Surface. People with disabilities, older people, and others benefit from continuous gripping surfaces that permit users to reach the fingers outward or downward to grasp the handrail, particularly as the user senses a loss of equilibrium or begins to fall. FIGURE 505.6 HORIZONTAL PROJECTIONS BELOW GRIPPING SURFACE 505.7 Cross Section. Handrail gripping surfaces shall have a cross section complying with 505.7.1 or 505.7.2. 505.7.1 Circular Cross Section. Handrail gripping surfaces with a circular cross section shall have an outside diameter of 11/4 inches (32 mm) minimum and 2 inches (51 mm) maximum. 505.7.2 Non-Circular Cross Sections. Handrail gripping surfaces with a non-circular cross section shall have a perimeter dimension of 4 inches (100 mm) minimum and 61/4 inches (160 mm) maximum, and a cross-section dimension of 21/4 inches (57 mm) maximum. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 103 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 5: GENERAL SITE AND BUILDING ELEMENTS TECHNICAL FIGURE 505.7.2 HANDRAIL NON-CIRCULAR CROSS SECTION 505.8 Surfaces. Handrail gripping surfaces and any surfaces adjacent to them shall be free of sharp or abrasive elements and shall have rounded edges. 505.9 Fittings. Handrails shall not rotate within their fittings. 505.10 Handrail Extensions. Handrail gripping surfaces shall extend beyond and in the same direction of stair flights and ramp runs in accordance with 505.10. EXCEPTIONS: 1. Extensions shall not be required for continuous handrails at the inside turn of switchback or dogleg stairs and ramps. 2. In assembly areas, extensions shall not be required for ramp handrails in aisles serving seating where the handrails are discontinuous to provide access to seating and to permit crossovers within aisles. 3. In alterations, full extensions of handrails shall not be required where such extensions would be hazardous due to plan configuration. 505.10.1 Top and Bottom Extension at Ramps. Ramp handrails shall extend horizontally above the landing for 12 inches (305 mm) minimum beyond the top and bottom of ramp runs. Extensions shall return to a wall, guard, or the landing surface, or shall be continuous to the handrail of an adjacent ramp run. FIGURE 505.10.1 TOP AND BOTTOM HANDRAIL EXTENSION AT RAMPS 505.10.2 Top Extension at Stairs. At the top of a stair flight, handrails shall extend horizontally above the landing for 12 inches (305 mm) minimum beginning directly above the first riser nosing. Extensions shall return to a wall, guard, or the landing surface, or shall be continuous to the handrail of an adjacent stair flight. 104 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 TECHNICAL CHAPTER 5: GENERAL SITE AND BUILDING ELEMENTS FIGURE 505.10.2 TOP HANDRAIL EXTENSION AT STAIRS 505.10.3 Bottom Extension at Stairs. At the bottom of a stair flight, handrails shall extend at the slope of the stair flight for a horizontal distance at least equal to one tread depth beyond the last riser nosing. Extension shall return to a wall, guard, or the landing surface, or shall be continuous to the handrail of an adjacent stair flight. FIGURE 505.10.3 BOTTOM HANDRAIL EXTENSION AT STAIRS FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 105 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 106 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 6: PLUMBING ELEMENTS AND FACILITIES 601 GENERAL 601.1 Scope. The provisions of Chapter 6 shall apply where required by Chapter 2 or where referenced by a requirement in this code. 602 DRINKING FOUNTAINS 602.1 General. Drinking fountains shall comply with 307 and 602. 602.2 Clear Floor Space. Units shall have a clear floor or ground space complying with 305 positioned for a forward approach and centered on the unit. Knee and toe clearance complying with 306 shall be provided. EXCEPTION: A parallel approach complying with 305 shall be permitted at units for children’s use where the spout is 30 inches (760 mm) maximum above the finish floor or ground and is 3 1/2 inches (90 mm) maximum from the front edge of the unit, including bumpers. 602.3 Operable Parts. Operable parts shall comply with 309. 602.4 Spout Height. Spout outlets shall be 36 inches (915 mm) maximum above the finish floor or ground. 602.5 Spout Location. The spout shall be located 15 inches (380 mm) minimum from the vertical support and 5 inches (125 mm) maximum from the front edge of the unit, including bumpers. FIGURE 602.5 DRINKING FOUNTAIN SPOUT LOCATION 602.6 Water Flow. The spout shall provide a flow of water 4 inches (100 mm) high minimum and shall be located 5 inches (125 mm) maximum from the front of the unit. The angle of the water stream shall be measured horizontally relative to the front face of the unit. Where spouts are located less than 3 inches (75 mm) of the front of the unit, the angle of the water stream shall be 30 degrees maximum. Where spouts are located between 3 inches (75 mm) and 5 inches (125 mm) maximum from the front of the unit, the angle of the water stream shall be 15 degrees maximum. Advisory 602.6 Water Flow. The purpose of requiring the drinking fountain spout to produce a flow of water 4 inches (100 mm) high minimum is so that a cup can be inserted under the flow of water to provide a drink of water for an individual who, because of a disability, would otherwise be incapable of using the drinking fountain. 602.7 Drinking Fountains for Standing Persons. Spout outlets of drinking fountains for standing persons shall be 38 inches (965 mm) minimum and 43 inches (1090 mm) maximum above the finish floor or ground. 603 TOILET AND BATHING ROOMS 603.1 General. Toilet and bathing rooms shall comply with 603. 603.2 Clearances. Clearances shall comply with 603.2. 603.2.1 Turning Space. Turning space complying with 304 shall be provided within the room. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 107 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 6: PLUMBING ELEMENTS AND FACILITIES TECHNICAL 603.2.2 Overlap. Required clear floor spaces, clearance at fixtures, and turning space shall be permitted to overlap. 603.2.3 Door Swing. Doors shall not swing into the clear floor space or clearance required for any fixture. Doors shall be permitted to swing into the required turning space. EXCEPTIONS: 1. Doors to a toilet room or bathing room for a single occupant accessed only through a private office and not for common use or public use shall be permitted to swing into the clear floor space or clearance provided the swing of the door can be reversed to comply with 603.2.3. 2. Where the toilet room or bathing room is for individual use and a clear floor space complying with 305.3 is provided within the room beyond the arc of the door swing, doors shall be permitted to swing into the clear floor space or clearance required for any fixture. Advisory 603.2.3 Door Swing Exception 1. At the time the door is installed, and if the door swing is reversed in the future, the door must meet all the requirements specified in 404. Additionally, the door swing cannot reduce the required width of an accessible route. Also, avoid violating other building or life safety codes when the door swing is reversed. 603.3 Mirrors. Mirrors located above lavatories or countertops shall be installed with the bottom edge of the reflecting surface 40 inches (1015 mm) maximum above the finish floor or ground. Mirrors not located above lavatories or countertops shall be installed with the bottom edge of the reflecting surface 35 inches (890 mm) maximum above the finish floor or ground. Advisory 603.3 Mirrors. A single full-length mirror can accommodate a greater number of people, including children. In order for mirrors to be usable by people who are ambulatory and people who use wheelchairs, the top edge of mirrors should be 74 inches (1880 mm) minimum from the floor or ground. 603.4 Coat Hooks and Shelves. Coat hooks shall be located within one of the reach ranges specified in 308. Shelves shall be located 40 inches (1015 mm) minimum and 48 inches (1220 mm) maximum above the finish floor. 604 WATER CLOSETS AND TOILET COMPARTMENTS 604.1 General. Water closets and toilet compartments shall comply with 604.2 through 604.8. EXCEPTION: Water closets and toilet compartments for children’s use shall be permitted to comply with 604.9. 604.2 Location. The water closet shall be positioned with a wall or partition to the rear and to one side. The centerline of the water closet shall be 16 inches (405 mm) minimum to 18 inches (455 mm) maximum from the side wall or partition, except that the water closet shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum from the side wall or partition in the ambulatory accessible toilet compartment specified in 604.8.2. Water closets shall be arranged for a left-hand or right-hand approach. FIGURE 604.2 WATER CLOSET LOCATION 108 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 TECHNICAL CHAPTER 6: PLUMBING ELEMENTS AND FACILITIES 604.3 Clearance. Clearances around water closets and in toilet compartments shall comply with 604.3. 604.3.1 Size. Clearance around a water closet shall be 60 inches (1525 mm) minimum measured perpendicular from the side wall and 56 inches (1420 mm) minimum measured perpendicular from the rear wall. FIGURE 604.3.1 SIZE OF CLEARANCE AT WATER CLOSETS 604.3.2 Overlap. The required clearance around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible routes, clear floor space and clearances required at other fixtures, and the turning space. No other fixtures or obstructions shall be located within the required water closet clearance. EXCEPTION: In residential dwelling units, a lavatory complying with 606 shall be permitted on the rear wall 18 inches (455 mm) minimum from the water closet centerline where the clearance at the water closet is 66 inches (1675 mm) minimum measured perpendicular from the rear wall. Advisory 604.3.2 Overlap. When the door to the toilet room is placed directly in front of the water closet, the water closet cannot overlap the required maneuvering clearance for the door inside the room. FIGURE 604.3.2 (EXCEPTION) OVERLAP OF WATER CLOSET CLEARANCE IN RESIDENTIAL DWELLING UNITS 604.4 Seats. The seat height of a water closet above the finish floor shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum measured to the top of the seat. Seats shall not be sprung to return to a lifted position. EXCEPTIONS: 1. A water closet in a toilet room for a single occupant accessed only through a private office and not for common use or public use shall not be required to comply with 604.4. 2. In residential dwelling units, the height of water closets shall be permitted to be 15 inches (380 mm) minimum and 19 inches (485 mm) maximum above the finish floor measured to the top of the seat. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 109 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 6: PLUMBING ELEMENTS AND FACILITIES TECHNICAL 604.5 Grab Bars. Grab bars for water closets shall comply with 609. Grab bars shall be provided on the side wall closest to the water closet and on the rear wall. EXCEPTIONS: 1. Grab bars shall not be required to be installed in a toilet room for a single occupant accessed only through a private office and not for common use or public use provided that reinforcement has been installed in walls and located so as to permit the installation of grab bars complying with 604.5. 2. In residential dwelling units, grab bars shall not be required to be installed in toilet or bathrooms provided that reinforcement has been installed in walls and located so as to permit the installation of grab bars complying with 604.5. 3. In detention or correction facilities, grab bars shall not be required to be installed in housing or holding cells that are specially designed without protrusions for purposes of suicide prevention. Advisory 604.5 Grab Bars Exception 2. Reinforcement must be sufficient to permit the installation of rear and side wall grab bars that fully meet all accessibility requirements including, but not limited to, required length, installation height, and structural strength. 604.5.1 Side Wall. The side wall grab bar shall be 42 inches (1065 mm) long minimum, located 12 inches (305 mm) maximum from the rear wall and extending 54 inches (1370 mm) minimum from the rear wall. FIGURE 604.5.1 SIDE WALL GRAB BAR AT WATER CLOSETS 604.5.2 Rear Wall. The rear wall grab bar shall be 36 inches (915 mm) long minimum and extend from the centerline of the water closet 12 inches (305 mm) minimum on one side and 24 inches (610 mm) minimum on the other side. EXCEPTIONS: 1. The rear grab bar shall be permitted to be 24 inches (610 mm) long minimum, centered on the water closet, where wall space does not permit a length of 36 inches (915 mm) minimum due to the location of a recessed fixture adjacent to the water closet. 2. Where an administrative authority requires flush controls for flush valves to be located in a position that conflicts with the location of the rear grab bar, then the rear grab bar shall be permitted to be split or shifted to the open side of the toilet area. 110 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 TECHNICAL CHAPTER 6: PLUMBING ELEMENTS AND FACILITIES FIGURE 604.5.2 REAR WALL GRAB BAR AT WATER CLOSETS 604.6 Flush Controls. Flush controls shall be hand operated or automatic. Hand operated flush controls shall comply with 309. Flush controls shall be located on the open side of the water closet except in ambulatory accessible compartments complying with 604.8.2. Advisory 604.6 Flush Controls. If plumbing valves are located directly behind the toilet seat, flush valves and related plumbing can cause injury or imbalance when a person leans back against them. To prevent causing injury or imbalance, the plumbing can be located behind walls or to the side of the toilet; or if approved by the local authority having jurisdiction, provide a toilet seat lid. 604.7 Dispensers. Toilet paper dispensers shall comply with 309.4 and shall be 7 inches (180 mm) minimum and 9 inches (230 mm) maximum in front of the water closet measured to the centerline of the dispenser. The outlet of the dispenser shall be 15 inches (380 mm) minimum and 48 inches (1220 mm) maximum above the finish floor and shall not be located behind grab bars. Dispensers shall not be of a type that controls delivery or that does not allow continuous paper flow. Advisory 604.7 Dispensers. If toilet paper dispensers are installed above the side wall grab bar, the outlet of the toilet paper dispenser must be 48 inches (1220 mm) maximum above the finish floor and the top of the gripping surface of the grab bar must be 33 inches (840 mm) minimum and 36 inches (915 mm) maximum above the finish floor. FIGURE 604.7 DISPENSER OUTLET LOCATION 604.8 Toilet Compartments. Wheelchair accessible toilet compartments shall meet the requirements of 604.8.1 and 604.8.3. Compartments containing more than one plumbing fixture shall comply with 603. Ambulatory accessible compartments shall comply with 604.8.2 and 604.8.3. 604.8.1 Wheelchair Accessible Compartments. Wheelchair accessible compartments shall comply with 604.8.1. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 111 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 6: PLUMBING ELEMENTS AND FACILITIES TECHNICAL 604.8.1.1 Size. Wheelchair accessible compartments shall be 60 inches (1525 mm) wide minimum measured perpendicular to the side wall, and 56 inches (1420 mm) deep minimum for wall hung water closets and 59 inches (1500 mm) deep minimum for floor mounted water closets measured perpendicular to the rear wall. Wheelchair accessible compartments for children’s use shall be 60 inches (1525 mm) wide minimum measured perpendicular to the side wall, and 59 inches (1500 mm) deep minimum for wall hung and floor mounted water closets measured perpendicular to the rear wall. Advisory 604.8.1.1 Size. The minimum space required in toilet compartments is provided so that a person using a wheelchair can maneuver into position at the water closet. This space cannot be obstructed by baby changing tables or other fixtures or conveniences, except as specified at 604.3.2 (Overlap). If toilet compartments are to be used to house fixtures other than those associated with the water closet, they must be designed to exceed the minimum space requirements. Convenience fixtures such as baby changing tables must also be accessible to people with disabilities as well as to other users. Toilet compartments that are designed to meet, and not exceed, the minimum space requirements may not provide adequate space for maneuvering into position at a baby changing table. FIGURE 604.8.1.1 SIZE OF WHEELCHAIR ACCESSIBLE TOILET COMPARTMENT 604.8.1.2 Doors. Toilet compartment doors, including door hardware, shall comply with 404 except that if the approach is to the latch side of the compartment door, clearance between the door side of the compartment and any obstruction shall be 42 inches (1065 mm) minimum. Doors shall be located in the front partition or in the side wall or partition farthest from the water closet. Where located in the front partition, the door opening shall be 4 inches (100 mm) maximum from the side wall or partition farthest from the water closet. Where located in the side wall or partition, the door opening shall be 4 inches (100 mm) maximum from the front partition. The door shall be self-closing. A door pull complying with 404.2.7 shall be placed on both sides of the door near the latch. Toilet compartment doors shall not swing into the minimum required compartment area. FIGURE 604.8.1.2 WHEELCHAIR ACCESSIBLE TOILET COMPARTMENT DOORS 112 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 TECHNICAL CHAPTER 6: PLUMBING ELEMENTS AND FACILITIES 604.8.1.3 Approach. Compartments shall be arranged for left-hand or right-hand approach to the water closet. 604.8.1.4 Toe Clearance. The front partition and at least one side partition shall provide a toe clearance of 9 inches (230 mm) minimum above the finish floor and 6 inches (150 mm) deep minimum beyond the compartment-side face of the partition, exclusive of partition support members. Compartments for children’s use shall provide a toe clearance of 12 inches (305 mm) minimum above the finish floor. EXCEPTION: Toe clearance at the front partition is not required in a compartment greater than 62 inches (1575 mm) deep with a wall-hung water closet or 65 inches (1650 mm) deep with a floor-mounted water closet. Toe clearance at the side partition is not required in a compartment greater than 66 inches (1675 mm) wide. Toe clearance at the front partition is not required in a compartment for children’s use that is greater than 65 inches (1650 mm) deep. FIGURE 604.8.1.4 WHEELCHAIR ACCESSIBLE TOILET COMPARTMENT TOE CLEARANCE 604.8.1.5 Grab Bars. Grab bars shall comply with 609. A side-wall grab bar complying with 604.5.1 shall be provided and shall be located on the wall closest to the water closet. In addition, a rear-wall grab bar complying with 604.5.2 shall be provided. 604.8.1.6 Lavatory. In new construction, the wheelchair accessible toilet compartment shall contain an accessible lavatory within it, which must be at least 19 inches wide by 17 inches deep, nominal size, and wall-mounted. The lavatory shall be mounted so as not to overlap the clear floor space areas required by section 604 for the wheelchair accessible toilet compartment and shall comply with section 606. Such lavatories shall be counted as part of the required fixture count for the building. See also section 213.3.4. 604.8.1.7 Water closet. In new construction, the accessible water closet within the wheelchair accessible compartment shall be located in the corner, diagonal to the door. FIGURE 604.8.1.6 WHEELCHAIR ACCESSIBLE TOILET COMPARTMENT IN NEW CONSTRUCTION Note: The drawings are not the complete code requirements, do not depict all possible options and the code text must be reviewed for additional requirements FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 113 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 6: PLUMBING ELEMENTS AND FACILITIES TECHNICAL Advisory 604.8.1.6 Lavatory and 604.8.1.7 Water Closet. Florida law, section 553.504(5), F.S., stipulates that “…required bathing rooms and toilet rooms in new construction shall be designed and constructed…” with an accessible lavatory in the wheelchair accessible compartment and the water closet located in a corner diagonal to the door. The ADA Standards for Accessible Design and therefore this code require wheelchair accessible compartments in new construction and in alterations of existing buildings to have self closing doors. While the Florida lavatory requirement and water closet placement apply only to new construction, they are desirable for all wheelchair accessible compartments and should be considered where feasible. 604.8.2 Ambulatory Accessible Compartments. Ambulatory accessible compartments shall comply with 604.8.2. FIGURE 604.8.2 AMBULATORY ACCESSIBLE TOILET COMPARTMENT 604.8.2.1 Size. Ambulatory accessible compartments shall have a depth of 60 inches (1525 mm) minimum and a width of 35 inches (890 mm) minimum and 37 inches (940 mm) maximum. 604.8.2.2 Doors. Toilet compartment doors, including door hardware, shall comply with 404, except that if the approach is to the latch side of the compartment door, clearance between the door side of the compartment and any obstruction shall be 42 inches (1065 mm) minimum. The door shall be self-closing. A door pull complying with 404.2.7 shall be placed on both sides of the door near the latch. Toilet compartment doors shall not swing into the minimum required compartment area. 604.8.2.3 Grab Bars. Grab bars shall comply with 609. A side-wall grab bar complying with 604.5.1 shall be provided on both sides of the compartment. 604.8.3 Coat Hooks and Shelves. Coat hooks shall be located within one of the reach ranges specified in 308. Shelves shall be located 40 inches (1015 mm) minimum and 48 inches (1220 mm) maximum above the finish floor. 604.9 Water Closets and Toilet Compartments for Children’s Use. Water closets and toilet compartments for children’s use shall comply with 604.9. Advisory 604.9 Water Closets and Toilet Compartments for Children’s Use. The requirements in 604.9 are to be followed where the exception for children’s water closets in 604.1 is used. The following table provides additional guidance in applying the specifications for water closets for children according to the age group served and reflects the differences in the size, stature, and reach ranges of children ages 3 through 12. The specifications chosen should correspond to the age of the primary user group. The specifications of one age group should be applied consistently in the installation of a water closet and related elements. 114 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 TECHNICAL CHAPTER 6: PLUMBING ELEMENTS AND FACILITIES ADVISORY SPECIFICATIONS FOR WATER CLOSETS SERVING CHILDREN AGES 3 THROUGH 12 Ages 3 and 4 Ages 5 through 8 Ages 9 through 12 Water Closet Centerline Toilet Seat Height Grab Bar Height Dispenser Height 12 inches (305 mm) 11 to 12 inches (280 to 305 mm) 18 to 20 inches (455 to 510 mm) 14 inches (355 mm) 12 to 15 inches (305 to 380 mm) 12 to 15 inches (305 to 380 mm) 20 to 25 inches (510 to 635 mm) 14 to 17 inches (355 to 430 mm) 15 to 18 inches (380 to 455 mm) 15 to 17 inches (380 to 430 mm) 25 to 27 inches (635 to 685 mm) 17 to 19 inches (430 to 485 mm) 604.9.1 Location. The water closet shall be located with a wall or partition to the rear and to one side. The centerline of the water closet shall be 12 inches (305 mm) minimum and 18 inches (455 mm) maximum from the side wall or partition, except that the water closet shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum from the side wall or partition in the ambulatory accessible toilet compartment specified in 604.8.2. Compartments shall be arranged for left-hand or right-hand approach to the water closet. 604.9.2 Clearance. Clearance around a water closet shall comply with 604.3. 604.9.3 Height. The height of water closets shall be 11 inches (280 mm) minimum and 17 inches (430 mm) maximum measured to the top of the seat. Seats shall not be sprung to return to a lifted position. 604.9.4 Grab Bars. Grab bars for water closets shall comply with 604.5. 604.9.5 Flush Controls. Flush controls shall be hand operated or automatic. Hand operated flush controls shall comply with 309.2 and 309.4 and shall be installed 36 inches (915 mm) maximum above the finish floor. Flush controls shall be located on the open side of the water closet except in ambulatory accessible compartments complying with 604.8.2. 604.9.6 Dispensers. Toilet paper dispensers shall comply with 309.4 and shall be 7 inches (180 mm) minimum and 9 inches (230 mm) maximum in front of the water closet measured to the centerline of the dispenser. The outlet of the dispenser shall be 14 inches (355 mm) minimum and 19 inches (485 mm) maximum above the finish floor. There shall be a clearance of 11/2 inches (38 mm) minimum below the grab bar. Dispensers shall not be of a type that controls delivery or that does not allow continuous paper flow. 604.9.7 Toilet Compartments. Toilet compartments shall comply with 604.8. 605 URINALS 605.1 General. Urinals shall comply with 605. Advisory 605.1 General. Stall-type urinals provide greater accessibility for a broader range of persons, including people of short stature. 605.2 Height and Depth. Urinals shall be the stall-type or the wall-hung type with the rim 17 inches (430 mm) maximum above the finish floor or ground. Urinals shall be 131/2 inches (345 mm) deep minimum measured from the outer face of the urinal rim to the back of the fixture. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 115 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 6: PLUMBING ELEMENTS AND FACILITIES TECHNICAL FIGURE 605.2 HEIGHT AND DEPTH OF URINALS 605.3 Clear Floor Space. A clear floor or ground space complying with 305 positioned for forward approach shall be provided. 605.4 Flush Controls. Flush controls shall be hand operated or automatic. Hand operated flush controls shall comply with 309. 606 LAVATORIES AND SINKS 606.1 General. Lavatories and sinks shall comply with 606. Advisory 606.1 General. If soap and towel dispensers are provided, they must be located within the reach ranges specified in 308. Locate soap and towel dispensers so that they are conveniently usable by a person at the accessible lavatory. 606.2 Clear Floor Space. A clear floor space complying with 305, positioned for a forward approach, and knee and toe clearance complying with 306 shall be provided. EXCEPTIONS: 1. A parallel approach complying with 305 shall be permitted to a kitchen sink, in a space where a cook top or conventional range is not provided, and to wet bars. 2. A lavatory in a toilet room or bathing facility for a single occupant accessed only through a private office and not for common use or public use shall not be required to provide knee and toe clearance complying with 306. 3. In residential dwelling units, cabinetry shall be permitted under lavatories and kitchen sinks provided that all of the following conditions are met: a. the cabinetry can be removed without removal or replacement of the fixture; b. the finish floor extends under the cabinetry; and c. the walls behind and surrounding the cabinetry are finished. 4. A knee clearance of 24 inches (610 mm) minimum above the finish floor or ground shall be permitted at lavatories and sinks used primarily by children 6 through 12 years where the rim or counter surface is 31 inches (785 mm) maximum above the finish floor or ground. 5. A parallel approach complying with 305 shall be permitted to lavatories and sinks used primarily by children 5 years and younger. 6. The dip of the overflow shall not be considered in determining knee and toe clearances. 7. No more than one bowl of a multi-bowl sink shall be required to provide knee and toe clearance complying with 306. 116 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 TECHNICAL CHAPTER 6: PLUMBING ELEMENTS AND FACILITIES 606.3 Height. Lavatories and sinks shall be installed with the front of the higher of the rim or counter surface 34 inches (865 mm) maximum above the finish floor or ground. EXCEPTIONS: 1. A lavatory in a toilet or bathing facility for a single occupant accessed only through a private office and not for common use or public use shall not be required to comply with 606.3. 2. In residential dwelling unit kitchens, sinks that are adjustable to variable heights, 29 inches (735 mm) minimum and 36 inches (915 mm) maximum, shall be permitted where rough-in plumbing permits connections of supply and drain pipes for sinks mounted at the height of 29 inches (735 mm). 606.4 Faucets. Controls for faucets shall comply with 309. Hand-operated metering faucets shall remain open for 10 seconds minimum. 606.5 Exposed Pipes and Surfaces. Water supply and drain pipes under lavatories and sinks shall be insulated or otherwise configured to protect against contact. There shall be no sharp or abrasive surfaces under lavatories and sinks. 607 BATHTUBS 607.1 General. Bathtubs shall comply with 607. 607.2 Clearance. Clearance in front of bathtubs shall extend the length of the bathtub and shall be 30 inches (760 mm) wide minimum. A lavatory complying with 606 shall be permitted at the control end of the clearance. Where a permanent seat is provided at the head end of the bathtub, the clearance shall extend 12 inches (305 mm) minimum beyond the wall at the head end of the bathtub. FIGURE 607.2 CLEARANCE FOR BATHTUBS 607.3 Seat. A permanent seat at the head end of the bathtub or a removable in-tub seat shall be provided. Seats shall comply with 610. 607.4 Grab Bars. Grab bars for bathtubs shall comply with 609 and shall be provided in accordance with 607.4.1 or 607.4.2. EXCEPTIONS: 1. Grab bars shall not be required to be installed in a bathtub located in a bathing facility for a single occupant accessed only through a private office and not for common use or public use provided that reinforcement has been installed in walls and located so as to permit the installation of grab bars complying with 607.4. 2. In residential dwelling units, grab bars shall not be required to be installed in bathtubs located in bathing facilities provided that reinforcement has been installed in walls and located so as to permit the installation of grab bars complying with 607.4. 607.4.1 Bathtubs With Permanent Seats. For bathtubs with permanent seats, grab bars shall be provided in accordance with 607.4.1. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 117 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 6: PLUMBING ELEMENTS AND FACILITIES TECHNICAL FIGURE 607.4.1 GRAB BARS FOR BATHTUBS WITH PERMANENT SEATS 607.4.1.1 Back Wall. Two grab bars shall be installed on the back wall, one located in accordance with 609.4 and the other located 8 inches (205 mm) minimum and 10 inches (255 mm) maximum above the rim of the bathtub. Each grab bar shall be installed 15 inches (380 mm) maximum from the head end wall and 12 inches (305 mm) maximum from the control end wall. 607.4.1.2 Control End Wall. A grab bar 24 inches (610 mm) long minimum shall be installed on the control end wall at the front edge of the bathtub. 607.4.2 Bathtubs Without Permanent Seats. For bathtubs without permanent seats, grab bars shall comply with 607.4.2. FIGURE 607.4.2 GRAB BARS FOR BATHTUBS WITH REMOVABLE IN-TUB SEATS 607.4.2.1 Back Wall. Two grab bars shall be installed on the back wall, one located in accordance with 609.4 and the other located 8 inches (205 mm) minimum and 10 inches (255 mm) maximum above the rim of the bathtub. Each grab bar shall be 24 inches (610 mm) long minimum and shall be installed 24 inches (610 mm) maximum from the head end wall and 12 inches (305 mm) maximum from the control end wall. 607.4.2.2 Control End Wall. A grab bar 24 inches (610 mm) long minimum shall be installed on the control end wall at the front edge of the bathtub. 607.4.2.3 Head End Wall. A grab bar 12 inches (305 mm) long minimum shall be installed on the head end wall at the front edge of the bathtub. 607.5 Controls. Controls, other than drain stoppers, shall be located on an end wall. Controls shall be between the bathtub rim and grab bar, and between the open side of the bathtub and the centerline of the width of the bathtub. Controls shall comply with 309.4. 118 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 TECHNICAL CHAPTER 6: PLUMBING ELEMENTS AND FACILITIES FIGURE 607.5 BATHTUB CONTROL LOCATION 607.6 Shower Spray Unit and Water. A shower spray unit with a hose 59 inches (1500 mm) long minimum that can be used both as a fixed-position shower head and as a hand-held shower shall be provided. The shower spray unit shall have an on/off control with a non-positive shut-off. If an adjustable-height shower head on a vertical bar is used, the bar shall be installed so as not to obstruct the use of grab bars. Bathtub shower spray units shall deliver water that is 120°F (49°C) maximum. Advisory 607.6 Shower Spray Unit and Water. Ensure that hand-held shower spray units are capable of delivering water pressure substantially equivalent to fixed shower heads. 607.7 Bathtub Enclosures. Enclosures for bathtubs shall not obstruct controls, faucets, shower and spray units or obstruct transfer from wheelchairs onto bathtub seats or into bathtubs. Enclosures on bathtubs shall not have tracks installed on the rim of the open face of the bathtub. 608 SHOWER COMPARTMENTS 608.1 General. Shower compartments shall comply with 608. Advisory 608.1 General. Shower stalls that are 60 inches (1525 mm) wide and have no curb may increase the usability of a bathroom because the shower area provides additional maneuvering space. 608.2 Size and Clearances for Shower Compartments. Shower compartments shall have sizes and clearances complying with 608.2. 608.2.1 Transfer Type Shower Compartments. Transfer type shower compartments shall be 36 inches (915 mm) by 36 inches (915 mm) clear inside dimensions measured at the center points of opposing sides and shall have a 36 inch (915 mm) wide minimum entry on the face of the shower compartment. Clearance of 36 inches (915 mm) wide minimum by 48 inches (1220 mm) long minimum measured from the control wall shall be provided. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 119 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 6: PLUMBING ELEMENTS AND FACILITIES TECHNICAL FIGURE 608.2.1 TRANSFER TYPE SHOWER COMPARTMENT SIZE AND CLEARANCE 608.2.2 Standard Roll-In Type Shower Compartments. Standard roll-in type shower compartments shall be 30 inches (760 mm) wide minimum by 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides and shall have a 60 inches (1525 mm) wide minimum entry on the face of the shower compartment. FIGURE 608.2.2 STANDARD ROLL-IN TYPE SHOWER COMPARTMENT SIZE AND CLEARANCE 608.2.2.1 Clearance. A 30 inch (760 mm) wide minimum by 60 inch (1525 mm) long minimum clearance shall be provided adjacent to the open face of the shower compartment. EXCEPTION: A lavatory complying with 606 shall be permitted on one 30 inch (760 mm) wide minimum side of the clearance provided that it is not on the side of the clearance adjacent to the controls or, where provided, not on the side of the clearance adjacent to the shower seat. 608.2.3 Alternate Roll-In Type Shower Compartments. Alternate roll-in type shower compartments shall be 36 inches (915 mm) wide and 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides. A 36 inch (915 mm) wide minimum entry shall be provided at one end of the long side of the compartment. 120 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 TECHNICAL CHAPTER 6: PLUMBING ELEMENTS AND FACILITIES FIGURE 608.2.3 ALTERNATE ROLL-IN TYPE SHOWER COMPARTMENT SIZE AND CLEARANCE 608.3 Grab Bars. Grab bars shall comply with 609 and shall be provided in accordance with 608.3. Where multiple grab bars are used, required horizontal grab bars shall be installed at the same height above the finish floor. EXCEPTIONS: 1. Grab bars shall not be required to be installed in a shower located in a bathing facility for a single occupant accessed only through a private office, and not for common use or public use provided that reinforcement has been installed in walls and located so as to permit the installation of grab bars complying with 608.3. 2. In residential dwelling units, grab bars shall not be required to be installed in showers located in bathing facilities provided that reinforcement has been installed in walls and located so as to permit the installation of grab bars complying with 608.3. 608.3.1 Transfer Type Shower Compartments. In transfer type compartments, grab bars shall be provided across the control wall and back wall to a point 18 inches (455 mm) from the control wall. FIGURE 608.3.1 GRAB BARS FOR TRANSFER TYPE SHOWERS 608.3.2 Standard Roll-In Type Shower Compartments. Where a seat is provided in standard roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall opposite the seat. Grab bars shall not be provided above the seat. Where a seat is not provided in standard roll-in type shower compartments, grab bars shall be provided on three walls. Grab bars shall be installed 6 inches (150 mm) maximum from adjacent walls. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 121 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 6: PLUMBING ELEMENTS AND FACILITIES TECHNICAL FIGURE 608.3.2 GRAB BARS FOR STANDARD ROLL-IN TYPE SHOWERS 608.3.3 Alternate Roll-In Type Shower Compartments. In alternate roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall farthest from the compartment entry. Grab bars shall not be provided above the seat. Grab bars shall be installed 6 inches (150 mm) maximum from adjacent walls. FIGURE 608.3.3 GRAB BARS FOR ALTERNATE ROLL-IN TYPE SHOWERS 608.4 Seats. A folding or non-folding seat shall be provided in transfer type shower compartments. A folding seat shall be provided in roll-in type showers required in transient lodging guest rooms with mobility features complying with 806.2. Seats shall comply with 610. EXCEPTION: In residential dwelling units, seats shall not be required in transfer type shower compartments provided that reinforcement has been installed in walls so as to permit the installation of seats complying with 608.4. 608.5 Controls. Controls, faucets, and shower spray units shall comply with 309.4. 608.5.1 Transfer Type Shower Compartments. In transfer type shower compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1220 mm) maximum above the shower floor and shall be located on the control wall 15 inches (380 mm) maximum from the centerline of the seat toward the shower opening. 122 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 TECHNICAL CHAPTER 6: PLUMBING ELEMENTS AND FACILITIES FIGURE 608.5.1 TRANSFER TYPE SHOWER COMPARTMENT CONTROL LOCATION 608.5.2 Standard Roll-In Type Shower Compartments. In standard roll-in type shower compartments, the controls, faucets, and shower spray unit shall be located above the grab bar, but no higher than 48 inches (1220 mm) above the shower floor. Where a seat is provided, the controls, faucets, and shower spray unit shall be installed on the back wall adjacent to the seat wall and shall be located 27 inches (685 mm) maximum from the seat wall. Advisory 608.5.2 Standard Roll-In Type Shower Compartments. In standard roll-in type showers without seats, the shower head and operable parts can be located on any of the three walls of the shower without adversely affecting accessibility. FIGURE 608.5.2 STANDARD ROLL-IN TYPE SHOWER COMPARTMENT CONTROL LOCATION 608.5.3 Alternate Roll-In Type Shower Compartments. In alternate roll-in type shower compartments, the controls, faucets, and shower spray unit shall be located above the grab bar, but no higher than 48 inches (1220 mm) above the shower floor. Where a seat is provided, the controls, faucets, and shower spray unit shall be located on the side wall adjacent to the seat 27 inches (685 mm) maximum from the side wall behind the seat or shall be located on the back wall opposite the seat 15 inches (380 mm) maximum, left or right, of the centerline of the seat. Where a seat is not provided, the controls, faucets, and shower spray unit shall be installed on the side wall farthest from the compartment entry. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 123 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 6: PLUMBING ELEMENTS AND FACILITIES TECHNICAL FIGURE 608.5.3 ALTERNATE ROLL-IN TYPE SHOWER COMPARTMENT CONTROL LOCATION 608.6 Shower Spray Unit and Water. A shower spray unit with a hose 59 inches (1500 mm) long minimum that can be used both as a fixed-position shower head and as a hand-held shower shall be provided. The shower spray unit shall have an on/off control with a non-positive shut-off. If an adjustable-height shower head on a vertical bar is used, the bar shall be installed so as not to obstruct the use of grab bars. Shower spray units shall deliver water that is 120°F (49°C) maximum. EXCEPTION: A fixed shower head located at 48 inches (1220 mm) maximum above the shower finish floor shall be permitted instead of a hand-held spray unit in facilities that are not medical care facilities, long-term care facilities, transient lodging guest rooms, or residential dwelling units. Advisory 608.6 Shower Spray Unit and Water. Ensure that hand-held shower spray units are capable of delivering water pressure substantially equivalent to fixed shower heads. 608.7 Thresholds. Thresholds in roll-in type shower compartments shall be 1/2 inch (13 mm) high maximum in accordance with 303. In transfer type shower compartments, thresholds 1/2 inch (13 mm) high maximum shall be beveled, rounded, or vertical. EXCEPTION: A threshold 2 inches (51 mm) high maximum shall be permitted in transfer type shower compartments in existing facilities where provision of a 1/2 inch (13 mm) high threshold would disturb the structural reinforcement of the floor slab. 608.8 Shower Enclosures. Enclosures for shower compartments shall not obstruct controls, faucets, and shower spray units or obstruct transfer from wheelchairs onto shower seats. 609 GRAB BARS 609.1 General. Grab bars in toilet facilities and bathing facilities shall comply with 609. 609.2 Cross Section. Grab bars shall have a cross section complying with 609.2.1 or 609.2.2. 609.2.1 Circular Cross Section. Grab bars with circular cross sections shall have an outside diameter of 11/4 inches (32 mm) minimum and 2 inches (51 mm) maximum. 609.2.2 Non-Circular Cross Section. Grab bars with non-circular cross sections shall have a cross-section dimension of 2 inches (51 mm) maximum and a perimeter dimension of 4 inches (100 mm) minimum and 4.8 inches (120 mm) maximum. 124 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 TECHNICAL CHAPTER 6: PLUMBING ELEMENTS AND FACILITIES FIGURE 609.2.2 GRAB BAR NON-CIRCULAR CROSS SECTION 609.3 Spacing. The space between the wall and the grab bar shall be 11/2 inches (38 mm). The space between the grab bar and projecting objects below and at the ends shall be 11/2 inches (38 mm) minimum. The space between the grab bar and projecting objects above shall be 12 inches (305 mm) minimum. EXCEPTION: The space between the grab bars and shower controls, shower fittings, and other grab bars above shall be permitted to be 11/2 inches (38 mm) minimum. FIGURE 609.3 SPACING OF GRAB BARS 609.4 Position of Grab Bars. Grab bars shall be installed in a horizontal position, 33 inches (840 mm) minimum and 36 inches (915 mm) maximum above the finish floor measured to the top of the gripping surface, except that at water closets for children’s use complying with 604.9, grab bars shall be installed in a horizontal position 18 inches (455 mm) minimum and 27 inches (685 mm) maximum above the finish floor measured to the top of the gripping surface. The height of the lower grab bar on the back wall of a bathtub shall comply with 607.4.1.1 or 607.4.2.1. 609.5 Surface Hazards. Grab bars and any wall or other surfaces adjacent to grab bars shall be free of sharp or abrasive elements and shall have rounded edges. 609.6 Fittings. Grab bars shall not rotate within their fittings. 609.7 Installation. Grab bars shall be installed in any manner that provides a gripping surface at the specified locations and that does not obstruct the required clear floor space. 609.8 Structural Strength. Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the grab bar, fastener, mounting device, or supporting structure. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 125 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 6: PLUMBING ELEMENTS AND FACILITIES TECHNICAL 610 SEATS 610.1 General. Seats in bathtubs and shower compartments shall comply with 610. 610.2 Bathtub Seats. The top of bathtub seats shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum above the bathroom finish floor. The depth of a removable in-tub seat shall be 15 inches (380 mm) minimum and 16 inches (405 mm) maximum. The seat shall be capable of secure placement. Permanent seats at the head end of the bathtub shall be 15 inches (380 mm) deep minimum and shall extend from the back wall to or beyond the outer edge of the bathtub. FIGURE 610.2 BATHTUB SEATS 610.3 Shower Compartment Seats. Where a seat is provided in a standard roll-in shower compartment, it shall be a folding type, shall be installed on the side wall adjacent to the controls, and shall extend from the back wall to a point within 3 inches (75 mm) of the compartment entry. Where a seat is provided in an alternate roll-in type shower compartment, it shall be a folding type, shall be installed on the front wall opposite the back wall, and shall extend from the adjacent side wall to a point within 3 inches (75 mm) of the compartment entry. In transfer-type showers, the seat shall extend from the back wall to a point within 3 inches (75 mm) of the compartment entry. The top of the seat shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum above the bathroom finish floor. Seats shall comply with 610.3.1 or 610.3.2. FIGURE 610.3 EXTENT OF SEAT 610.3.1 Rectangular Seats. The rear edge of a rectangular seat shall be 21/2 inches (64 mm) maximum and the front edge 15 inches (380 mm) minimum and 16 inches (405 mm) maximum from the seat wall. The side edge of the seat shall be 11/2 inches (38 mm) maximum from the adjacent wall. 126 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 TECHNICAL CHAPTER 6: PLUMBING ELEMENTS AND FACILITIES FIGURE 610.3.1 RECTANGULAR SHOWER SEAT 610.3.2 L-Shaped Seats. The rear edge of an L-shaped seat shall be 21/2 inches (64 mm) maximum and the front edge 15 inches (380 mm) minimum and 16 inches (405 mm) maximum from the seat wall. The rear edge of the “L” portion of the seat shall be 11/2 inches (38 mm) maximum from the wall and the front edge shall be 14 inches (355 mm) minimum and 15 inches (380 mm) maximum from the wall. The end of the “L” shall be 22 inches (560 mm) minimum and 23 inches maximum (585 mm) from the main seat wall. FIGURE 610.3.2 L-SHAPED SHOWER SEAT 610.4 Structural Strength. Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the seat, fastener, mounting device, or supporting structure. 611 WASHING MACHINES AND CLOTHES DRYERS 611.1 General. Washing machines and clothes dryers shall comply with 611. 611.2 Clear Floor Space. A clear floor or ground space complying with 305 positioned for parallel approach shall be provided. The clear floor or ground space shall be centered on the appliance. 611.3 Operable Parts. Operable parts, including doors, lint screens, and detergent and bleach compartments shall comply with 309. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 127 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 6: PLUMBING ELEMENTS AND FACILITIES TECHNICAL 611.4 Height. Top loading machines shall have the door to the laundry compartment located 36 inches (915 mm) maximum above the finish floor. Front loading machines shall have the bottom of the opening to the laundry compartment located 15 inches (380 mm) minimum and 36 inches (915 mm) maximum above the finish floor. FIGURE 611.4 HEIGHT OF LAUNDRY COMPARTMENT OPENING 612 SAUNAS AND STEAM ROOMS 612.1 General. Saunas and steam rooms shall comply with 612. 612.2 Bench. Where seating is provided in saunas and steam rooms, at least one bench shall comply with 903. Doors shall not swing into the clear floor space required by 903.2. EXCEPTION: A readily removable bench shall be permitted to obstruct the turning space required by 612.3 and the clear floor or ground space required by 903.2. 612.3 Turning Space. A turning space complying with 304 shall be provided within saunas and steam rooms. 128 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 7: COMMUNICATION ELEMENTS AND FEATURES 701 GENERAL 701.1 Scope. The provisions of Chapter 7 shall apply where required by Chapter 2 or where referenced by a requirement in this code. 702 FIRE ALARM SYSTEMS 702.1 General. Fire alarm systems shall have permanently installed audible and visible alarms complying with NFPA 72 (1999 or 2002 edition) (incorporated by reference, see “Referenced Standards” in Chapter 1), except that the maximum allowable sound level of audible notification appliances complying with section 4-3.2.1 of NFPA 72 (1999 edition) shall have a sound level no more than 110 dB at the minimum hearing distance from the audible appliance. In addition, alarms in guest rooms required to provide communication features shall comply with sections 4-3 and 44 of NFPA 72 (1999 edition) or sections 7.4 and 7.5 of NFPA 72 (2002 edition). EXCEPTION: Fire alarm systems in medical care facilities shall be permitted to be provided in accordance with industry practice. 703 SIGNS 703.1 General. Signs shall comply with 703. Where both visual and tactile characters are required, either one sign with both visual and tactile characters, or two separate signs, one with visual, and one with tactile characters, shall be provided. 703.2 Raised Characters. Raised characters shall comply with 703.2 and shall be duplicated in braille complying with 703.3. Raised characters shall be installed in accordance with 703.4. Advisory 703.2 Raised Characters. Signs that are designed to be read by touch should not have sharp or abrasive edges. 703.2.1 Depth. Raised characters shall be 1/32 inch (0.8 mm) minimum above their background. 703.2.2 Case. Characters shall be uppercase. 703.2.3 Style. Characters shall be sans serif. Characters shall not be italic, oblique, script, highly decorative, or of other unusual forms. 703.2.4 Character Proportions. Characters shall be selected from fonts where the width of the uppercase letter “O” is 55 percent minimum and 110 percent maximum of the height of the uppercase letter “I”. 703.2.5 Character Height. Character height measured vertically from the baseline of the character shall be 5/8 inch (16 mm) minimum and 2 inches (51 mm) maximum based on the height of the uppercase letter “I”. EXCEPTION: Where separate raised and visual characters with the same information are provided, raised character height shall be permitted to be 1/2 inch (13 mm) minimum. FIGURE 703.2.5 HEIGHT OF RAISED CHARACTERS 703.2.6 Stroke Thickness. Stroke thickness of the uppercase letter “I” shall be 15 percent maximum of the height of the character. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 129 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 7: COMMUNICATION ELEMENTS AND FEATURES TECHNICAL 703.2.7 Character Spacing. Character spacing shall be measured between the two closest points of adjacent raised characters within a message, excluding word spaces. Where characters have rectangular cross sections, spacing between individual raised characters shall be 1/8 inch (3.2 mm) minimum and 4 times the raised character stroke width maximum. Where characters have other cross sections, spacing between individual raised characters shall be 1/16 inch (1.6 mm) minimum and 4 times the raised character stroke width maximum at the base of the cross sections, and 1/8 inch (3.2 mm) minimum and 4 times the raised character stroke width maximum at the top of the cross sections. Characters shall be separated from raised borders and decorative elements 3/8 inch (9.5 mm) minimum. 703.2.8 Line Spacing. Spacing between the baselines of separate lines of raised characters within a message shall be 135 percent minimum and 170 percent maximum of the raised character height. 703.3 Braille. Braille shall be contracted (Grade 2) and shall comply with 703.3 and 703.4. 703.3.1 Dimensions and Capitalization. Braille dots shall have a domed or rounded shape and shall comply with Table 703.3.1. The indication of an uppercase letter or letters shall only be used before the first word of sentences, proper nouns and names, individual letters of the alphabet, initials, and acronyms. TABLE 703.3.1 BRAILLE DIMENSIONS MEASUREMENT RANGE MINIMUM IN INCHES MAXIMUM IN INCHES Dot base diameter Distance between two dots in the same cell1 Distance between corresponding dots in adjacent cells1 Dot height Distance between corresponding dots from one cell directly below1 0.059 (1.5 mm) to 0.063 (1.6 mm) 0.090 (2.3 mm) to 0.100 (2.5 mm) 0.241 (6.1 mm) to 0.300 (7.6 mm) 0.025 (0.6 mm) to 0.037 (0.9 mm) 0.395 (10 mm) to 0.400 (10.2 mm) 1. Measured center to center. FIGURE 703.3.1 BRAILLE MEASUREMENT 703.3.2 Position. Braille shall be positioned below the corresponding text. If text is multi-lined, braille shall be placed below the entire text. Braille shall be separated 3/8 inch (9.5 mm) minimum from any other tactile characters and 3/8 inch (9.5 mm) minimum from raised borders and decorative elements. EXCEPTION: Braille provided on elevator car controls shall be separated 3/16 inch (4.8 mm) minimum and shall be located either directly below or adjacent to the corresponding raised characters or symbols. 130 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 TECHNICAL CHAPTER 7: COMMUNICATION ELEMENTS AND FEATURES FIGURE 703.3.2 POSITION OF BRAILLE 703.4 Installation Height and Location. Signs with tactile characters shall comply with 703.4. 703.4.1 Height Above Finish Floor or Ground. Tactile characters on signs shall be located 48 inches (1220 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest tactile character and 60 inches (1525 mm) maximum above the finish floor or ground surface, measured from the baseline of the highest tactile character. EXCEPTION: Tactile characters for elevator car controls shall not be required to comply with 703.4.1. FIGURE 703.4.1 HEIGHT OF TACTILE CHARACTERS ABOVE FINISH FLOOR OR GROUND 703.4.2 Location. Where a tactile sign is provided at a door, the sign shall be located alongside the door at the latch side. Where a tactile sign is provided at double doors with one active leaf, the sign shall be located on the inactive leaf. Where a tactile sign is provided at double doors with two active leafs, the sign shall be located to the right of the right hand door. Where there is no wall space at the latch side of a single door or at the right side of double doors, signs shall be located on the nearest adjacent wall. Signs containing tactile characters shall be located so that a clear floor space of 18 inches (455 mm) minimum by 18 inches (455 mm) minimum, centered on the tactile characters, is provided beyond the arc of any door swing between the closed position and 45 degree open position. EXCEPTION: Signs with tactile characters shall be permitted on the push side of doors with closers and without hold-open devices. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 131 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 7: COMMUNICATION ELEMENTS AND FEATURES TECHNICAL FIGURE 703.4.2 LOCATION OF TACTILE SIGNS AT DOORS 703.5 Visual Characters. Visual characters shall comply with 703.5. EXCEPTION: Where visual characters comply with 703.2 and are accompanied by braille complying with 703.3, they shall not be required to comply with 703.5.2 through 703.5.9. 703.5.1 Finish and Contrast. Characters and their background shall have a non-glare finish. Characters shall contrast with their background with either light characters on a dark background or dark characters on a light background. Advisory 703.5.1 Finish and Contrast. Signs are more legible for persons with low vision when characters contrast as much as possible with their background. Additional factors affecting the ease with which the text can be distinguished from its background include shadows cast by lighting sources, surface glare, and the uniformity of the text and its background colors and textures. 703.5.2 Case. Characters shall be uppercase or lowercase or a combination of both. 703.5.3 Style. Characters shall be conventional in form. Characters shall not be italic, oblique, script, highly decorative, or of other unusual forms. 703.5.4 Character Proportions. Characters shall be selected from fonts where the width of the uppercase letter “O” is 55 percent minimum and 110 percent maximum of the height of the uppercase letter “I”. 703.5.5 Character Height. Minimum character height shall comply with Table 703.5.5. Viewing distance shall be measured as the horizontal distance between the character and an obstruction preventing further approach towards the sign. Character height shall be based on the uppercase letter “I”. TABLE 703.5.5 VISUAL CHARACTER HEIGHT HEIGHT TO FINISH FLOOR OR GROUND FROM BASELINE OF CHARACTER HORIZONTAL VIEWING DISTANCE less than 72 inches (1830 mm) 40 inches (1015 mm) to less than or equal to 70 inches (1780 mm) Greater than 70 inches (1780 mm) to less than or equal to 120 inches (3050 mm) 72 inches (1830 mm) and greater less than 180 inches (4570 mm) 180 inches (4570 mm) and greater less than 21 feet (6400 mm) Greater than 120 inches (3050 mm) 132 21 feet (6400 mm) and greater MINIMUM CHARACTER HEIGHT 5/8 inch (16 mm) 5/8 inch (16 mm), plus 1/8 inch (3.2 mm) per foot (305 mm) of viewing distance above 72 inches (1830 mm) 2 inches (51 mm) 2 inches (51 mm), plus 1/8 inch (3.2 mm) per foot (305 mm) of viewing distance above 180 inches (4570 mm) 3 inches (75 mm) 3 inches (75 mm), plus 1/8 inch (3.2 mm) per foot (305 mm) of viewing distance above 21 feet (6400 mm) FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 TECHNICAL CHAPTER 7: COMMUNICATION ELEMENTS AND FEATURES 703.5.6 Height From Finish Floor or Ground. Visual characters shall be 40 inches (1015 mm) minimum above the finish floor or ground. EXCEPTION: Visual characters indicating elevator car controls shall not be required to comply with 703.5.6. 703.5.7 Stroke Thickness. Stroke thickness of the uppercase letter “I” shall be 10 percent minimum and 30 percent maximum of the height of the character. 703.5.8 Character Spacing. Character spacing shall be measured between the two closest points of adjacent characters, excluding word spaces. Spacing between individual characters shall be 10 percent minimum and 35 percent maximum of character height. 703.5.9 Line Spacing. Spacing between the baselines of separate lines of characters within a message shall be 135 percent minimum and 170 percent maximum of the character height. 703.6 Pictograms. Pictograms shall comply with 703.6. 703.6.1 Pictogram Field. Pictograms shall have a field height of 6 inches (150 mm) minimum. Characters and braille shall not be located in the pictogram field. FIGURE 703.6.1 PICTOGRAM FIELD 703.6.2 Finish and Contrast. Pictograms and their field shall have a non-glare finish. Pictograms shall contrast with their field with either a light pictogram on a dark field or a dark pictogram on a light field. Advisory 703.6.2 Finish and Contrast. Signs are more legible for persons with low vision when characters contrast as much as possible with their background. Additional factors affecting the ease with which the text can be distinguished from its background include shadows cast by lighting sources, surface glare, and the uniformity of the text and background colors and textures. 703.6.3 Text Descriptors. Pictograms shall have text descriptors located directly below the pictogram field. Text descriptors shall comply with 703.2, 703.3 and 703.4. 703.7 Symbols of Accessibility. Symbols of accessibility shall comply with 703.7. 703.7.1 Finish and Contrast. Symbols of accessibility and their background shall have a non-glare finish. Symbols of accessibility shall contrast with their background with either a light symbol on a dark background or a dark symbol on a light background. Advisory 703.7.1 Finish and Contrast. Signs are more legible for persons with low vision when characters contrast as much as possible with their background. Additional factors affecting the ease with which the text can be distinguished from its background include shadows cast by lighting sources, surface glare, and the uniformity of the text and background colors and textures. 703.7.2 Symbols. 703.7.2.1 International Symbol of Accessibility. The International Symbol of Accessibility shall comply with Figure 703.7.2.1. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 133 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 7: COMMUNICATION ELEMENTS AND FEATURES TECHNICAL FIGURE 703.7.2.1 INTERNATIONAL SYMBOL OF ACCESSIBILITY 703.7.2.2 International Symbol of TTY. The International Symbol of TTY shall comply with Figure 703.7.2.2. FIGURE 703.7.2.2 INTERNATIONAL SYMBOL OF TTY 703.7.2.3 Volume Control Telephones. Telephones with a volume control shall be identified by a pictogram of a telephone handset with radiating sound waves on a square field such as shown in Figure 703.7.2.3. FIGURE 703.7.2.3 VOLUME CONTROL TELEPHONE 703.7.2.4 Assistive Listening Systems. Assistive listening systems shall be identified by the International Symbol of Access for Hearing Loss complying with Figure 703.7.2.4. FIGURE 703.7.2.4 INTERNATIONAL SYMBOL OF ACCESS FOR HEARING LOSS 134 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 TECHNICAL CHAPTER 7: COMMUNICATION ELEMENTS AND FEATURES 704 TELEPHONES 704.1 General. Public telephones shall comply with 704. 704.2 Wheelchair Accessible Telephones. Wheelchair accessible telephones shall comply with 704.2. 704.2.1 Clear Floor or Ground Space. A clear floor or ground space complying with 305 shall be provided. The clear floor or ground space shall not be obstructed by bases, enclosures, or seats. Advisory 704.2.1 Clear Floor or Ground Space. Because clear floor and ground space is required to be unobstructed, telephones, enclosures and related telephone book storage cannot encroach on the required clear floor or ground space and must comply with the provisions for protruding objects. (See Section 307). 704.2.1.1 Parallel Approach. Where a parallel approach is provided, the distance from the edge of the telephone enclosure to the face of the telephone unit shall be 10 inches (255 mm) maximum. FIGURE 704.2.1.1 PARALLEL APPROACH TO TELEPHONE 704.2.1.2 Forward Approach. Where a forward approach is provided, the distance from the front edge of a counter within the telephone enclosure to the face of the telephone unit shall be 20 inches (510 mm) maximum. FIGURE 704.2.1.2 FORWARD APPROACH TO TELEPHONE 704.2.2 Operable Parts. Operable parts shall comply with 309. Telephones shall have push-button controls where such service is available. 704.2.3 Telephone Directories. Telephone directories, where provided, shall be located in accordance with 309. 704.2.4 Cord Length. The cord from the telephone to the handset shall be 29 inches (735 mm) long minimum. 704.3 Volume Control Telephones. Public telephones required to have volume controls shall be equipped with a receive volume control that provides a gain adjustable up to 20 dB minimum. For incremental volume control, provide at least one intermediate step of 12 dB of gain minimum. An automatic reset shall be provided. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 135 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 7: COMMUNICATION ELEMENTS AND FEATURES TECHNICAL Advisory 704.3 Volume Control Telephones. Amplifiers on pay phones are located in the base or the handset or are built into the telephone. Most are operated by pressing a button or key. If the microphone in the handset is not being used, a mute button that temporarily turns off the microphone can also reduce the amount of background noise which the person hears in the earpiece. If a volume adjustment is provided that allows the user to set the level anywhere from the base volume to the upper requirement of 20 dB, there is no need to specify a lower limit. If a stepped volume control is provided, one of the intermediate levels must provide 12 dB of gain. Consider compatibility issues when matching an amplified handset with a phone or phone system. Amplified handsets that can be switched with pay telephone handsets are available. Portable and in-line amplifiers can be used with some phones but are not practical at most public phones covered by these requirements. 704.4 TTYs. TTYs required at a public pay telephone shall be permanently affixed within, or adjacent to, the telephone enclosure. Where an acoustic coupler is used, the telephone cord shall be sufficiently long to allow connection of the TTY and the telephone receiver. Advisory 704.4 TTYs. Ensure that sufficient electrical service is available where TTYs are to be installed. 704.4.1 Height. When in use, the touch surface of TTY keypads shall be 34 inches (865 mm) minimum above the finish floor. EXCEPTION: Where seats are provided, TTYs shall not be required to comply with 704.4.1. Advisory 704.4.1 Height. A telephone with a TTY installed underneath cannot also be a wheelchair accessible telephone because the required 34 inches (865 mm) minimum keypad height can cause the highest operable part of the telephone, usually the coin slot, to exceed the maximum permitted side and forward reach ranges. (See Section 308). Advisory 704.4.1 Height Exception. While seats are not required at TTYs, reading and typing at a TTY is more suited to sitting than standing. Facilities that often provide seats at TTY’s include, but are not limited to, airports and other passenger terminals or stations, courts, art galleries, and convention centers. 704.5 TTY Shelf. Public pay telephones required to accommodate portable TTYs shall be equipped with a shelf and an electrical outlet within or adjacent to the telephone enclosure. The telephone handset shall be capable of being placed flush on the surface of the shelf. The shelf shall be capable of accommodating a TTY and shall have 6 inches (150 mm) minimum vertical clearance above the area where the TTY is to be placed. 705 DETECTABLE WARNINGS 705.1 General. Detectable warnings shall consist of a surface of truncated domes and shall comply with 705. FIGURE 705.1 SIZE AND SPACING OF TRUNCATED DOMES 705.1.1 Dome Size. Truncated domes in a detectable warning surface shall have a base diameter of 0.9 inch (23 mm) minimum and 1.4 inches (36 mm) maximum, a top diameter of 50 percent of the base diameter minimum to 65 percent of the base diameter maximum, and a height of 0.2 inch (5.1 mm). 705.1.2 Dome Spacing. Truncated domes in a detectable warning surface shall have a center-to-center spacing of 1.6 inches (41 mm) minimum and 2.4 inches (61 mm) maximum, and a base-to-base spacing of 0.65 inch (17 mm) minimum, measured between the most adjacent domes on a square grid. 136 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 TECHNICAL CHAPTER 7: COMMUNICATION ELEMENTS AND FEATURES 705.1.3 Contrast. Detectable warning surfaces shall contrast visually with adjacent walking surfaces either lighton-dark, or dark-on-light. 705.2 Platform Edges. Detectable warning surfaces at platform boarding edges shall be 24 inches (610 mm) wide and shall extend the full length of the public use areas of the platform. 706 ASSISTIVE LISTENING SYSTEMS 706.1 General. Assistive listening systems required in assembly areas shall comply with 706. Advisory 706.1 General. Assistive listening systems are generally categorized by their mode of transmission. There are hard-wired systems and three types of wireless systems: induction loop, infrared, and FM radio transmission. Each has different advantages and disadvantages that can help determine which system is best for a given application. For example, an FM system may be better than an infrared system in some open-air assemblies since infrared signals are less effective in sunlight. On the other hand, an infrared system is typically a better choice than an FM system where confidential transmission is important because it will be contained within a given space. The technical standards for assistive listening systems describe minimum performance levels for volume, interference, and distortion. Sound pressure levels (SPL), expressed in decibels, measure output sound volume. Signal-to-noise ratio (SNR or S/N), also expressed in decibels, represents the relationship between the loudness of a desired sound (the signal) and the background noise in a space or piece of equipment. The higher the SNR, the more intelligible the signal. The peak clipping level limits the distortion in signal output produced when high-volume sound waves are manipulated to serve assistive listening devices. Selecting or specifying an effective assistive listening system for a large or complex venue requires assistance from a professional sound engineer. The Access Board has published technical assistance on assistive listening devices and systems. 706.2 Receiver Jacks. Receivers required for use with an assistive listening system shall include a 1/8 inch (3.2 mm) standard mono jack. 706.3 Receiver Hearing-Aid Compatibility. Receivers required to be hearing-aid compatible shall interface with telecoils in hearing aids through the provision of neckloops. Advisory 706.3 Receiver Hearing-Aid Compatibility. Neckloops and headsets that can be worn as neckloops are compatible with hearing aids. Receivers that are not compatible include earbuds, which may require removal of hearing aids, earphones, and headsets that must be worn over the ear, which can create disruptive interference in the transmission and can be uncomfortable for people wearing hearing aids. 706.4 Sound Pressure Level. Assistive listening systems shall be capable of providing a sound pressure level of 110 dB minimum and 118 dB maximum with a dynamic range on the volume control of 50 dB. 706.5 Signal-to-Noise Ratio. The signal-to-noise ratio for internally generated noise in assistive listening systems shall be 18 dB minimum. 706.6 Peak Clipping Level. Peak clipping shall not exceed 18 dB of clipping relative to the peaks of speech. 707 AUTOMATIC TELLER MACHINES AND FARE MACHINES Advisory 707 Automatic Teller Machines and Fare Machines. Interactive transaction machines (ITMs), other than ATMs, are not covered by Section 707. However, for entities covered by the ADA, the Department of Justice regulations that implement the ADA provide additional guidance regarding the relationship between these requirements and elements that are not directly addressed by these requirements. Federal procurement law requires that ITMs purchased by the Federal government comply with standards issued by the Access Board under Section 508 of the Rehabilitation Act of 1973, as amended. This law covers a variety of products, including computer hardware and software, web sites, phone systems, fax machines, copiers, and similar technologies. For more information on Section 508 consult the Access Board’s web site at www.access-board.gov. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 137 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 7: COMMUNICATION ELEMENTS AND FEATURES TECHNICAL 707.1 General. Automatic teller machines and fare machines shall comply with 707. Advisory 707.1 General. If farecards have one tactually distinctive corner they can be inserted with greater accuracy. Token collection devices that are designed to accommodate tokens which are perforated can allow a person to distinguish more readily between tokens and common coins. Place accessible gates and fare vending machines in close proximity to other accessible elements when feasible so the facility is easier to use. 707.2 Clear Floor or Ground Space. A clear floor or ground space complying with 305 shall be provided. EXCEPTION: Clear floor or ground space shall not be required at drive-up only automatic teller machines and fare machines. 707.3 Operable Parts. Operable parts shall comply with 309. Unless a clear or correct key is provided, each operable part shall be able to be differentiated by sound or touch, without activation. EXCEPTION: Drive-up only automatic teller machines and fare machines shall not be required to comply with 309.2 and 309.3. 707.4 Privacy. Automatic teller machines shall provide the opportunity for the same degree of privacy of input and output available to all individuals. Advisory 707.4 Privacy. In addition to people who are blind or visually impaired, people with limited reach who use wheelchairs or have short stature, who cannot effectively block the ATM screen with their bodies, may prefer to use speech output. Speech output users can benefit from an option to render the visible screen blank, thereby affording them greater personal security and privacy. 707.5 Speech Output. Machines shall be speech enabled. Operating instructions and orientation, visible transaction prompts, user input verification, error messages, and all displayed information for full use shall be accessible to and independently usable by individuals with vision impairments. Speech shall be delivered through a mechanism that is readily available to all users, including but not limited to, an industry standard connector or a telephone handset. Speech shall be recorded or digitized human, or synthesized. EXCEPTIONS: 1. Audible tones shall be permitted instead of speech for visible output that is not displayed for security purposes, including but not limited to, asterisks representing personal identification numbers. 2. Advertisements and other similar information shall not be required to be audible unless they convey information that can be used in the transaction being conducted. 3. Where speech synthesis cannot be supported, dynamic alphabetic output shall not be required to be audible. Advisory 707.5 Speech Output. If an ATM provides additional functions such as dispensing coupons, selling theater tickets, or providing copies of monthly statements, all such functions must be available to customers using speech output. To avoid confusion at the ATM, the method of initiating the speech mode should be easily discoverable and should not require specialized training. For example, if a telephone handset is provided, lifting the handset can initiate the speech mode. 707.5.1 User Control. Speech shall be capable of being repeated or interrupted. Volume control shall be provided for the speech function. EXCEPTION: Speech output for any single function shall be permitted to be automatically interrupted when a transaction is selected. 707.5.2 Receipts. Where receipts are provided, speech output devices shall provide audible balance inquiry information, error messages, and all other information on the printed receipt necessary to complete or verify the transaction. EXCEPTIONS: 1. Machine location, date and time of transaction, customer account number, and the machine identifier shall not be required to be audible. 138 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 TECHNICAL CHAPTER 7: COMMUNICATION ELEMENTS AND FEATURES 2. Information on printed receipts that duplicates information available on-screen shall not be required to be presented in the form of an audible receipt. 3. Printed copies of bank statements and checks shall not be required to be audible. 707.6 Input. Input devices shall comply with 707.6. 707.6.1 Input Controls. At least one tactilely discernible input control shall be provided for each function. Where provided, key surfaces not on active areas of display screens, shall be raised above surrounding surfaces. Where membrane keys are the only method of input, each shall be tactilely discernable from surrounding surfaces and adjacent keys. 707.6.2 Numeric Keys. Numeric keys shall be arranged in a 12-key ascending or descending telephone keypad layout. The number five key shall be tactilely distinct from the other keys. Advisory 707.6.2 Numeric Keys. Telephone keypads and computer keyboards differ in one significant feature, ascending versus descending numerical order. Both types of keypads are acceptable, provided the computer-style keypad is organized similarly to the number pad located at the right on most computer keyboards, and does not resemble the line of numbers located above the computer keys. FIGURE 707.6.2 NUMERIC KEY LAYOUT 707.6.3 Function Keys. Function keys shall comply with 707.6.3. 707.6.3.1 Contrast. Function keys shall contrast visually from background surfaces. Characters and symbols on key surfaces shall contrast visually from key surfaces. Visual contrast shall be either light-on-dark or darkon-light. EXCEPTION: Tactile symbols required by 707.6.3.2 shall not be required to comply with 707.6.3.1. 707.6.3.2 Tactile Symbols. Function key surfaces shall have tactile symbols as follows: Enter or Proceed key: raised circle; Clear or Correct key: raised left arrow; Cancel key: raised letter ex; Add Value key: raised plus sign; Decrease Value key: raised minus sign. 707.7 Display Screen. The display screen shall comply with 707.7. EXCEPTION: Drive-up only automatic teller machines and fare machines shall not be required to comply with 707.7.1. 707.7.1 Visibility. The display screen shall be visible from a point located 40 inches (1015 mm) above the center of the clear floor space in front of the machine. 707.7.2 Characters. Characters displayed on the screen shall be in a sans serif font. Characters shall be 3/16 inch (4.8 mm) high minimum based on the uppercase letter “I”. Characters shall contrast with their background with either light characters on a dark background or dark characters on a light background. 707.8 Braille Instructions. Braille instructions for initiating the speech mode shall be provided. Braille shall comply with 703.3. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 139 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 7: COMMUNICATION ELEMENTS AND FEATURES TECHNICAL 708 TWO-WAY COMMUNICATION SYSTEMS 708.1 General. Two-way communication systems shall comply with 708. Advisory 708.1 General. Devices that do not require handsets are easier to use by people who have a limited reach. 708.2 Audible and Visual Indicators. The system shall provide both audible and visual signals. Advisory 708.2 Audible and Visual Indicators. A light can be used to indicate visually that assistance is on the way. Signs indicating the meaning of visual signals should be provided. 708.3 Handsets. Handset cords, if provided, shall be 29 inches (735 mm) long minimum. 708.4 Residential Dwelling Unit Communication Systems. Communications systems between a residential dwelling unit and a site, building, or floor entrance shall comply with 708.4. 708.4.1 Common Use or Public Use System Interface. The common use or public use system interface shall include the capability of supporting voice and TTY communication with the residential dwelling unit interface. 708.4.2 Residential Dwelling Unit Interface. The residential dwelling unit system interface shall include a telephone jack capable of supporting voice and TTY communication with the common use or public use system interface. 140 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 8: SPECIAL ROOMS, SPACES AND ELEMENTS 801 GENERAL 801.1 Scope. The provisions of Chapter 8 shall apply where required by Chapter 2 or where referenced by a requirement in this code. Advisory 801.1 Scope. Facilities covered by these requirements are also subject to the requirements of the other chapters. For example, 806 addresses guest rooms in transient lodging facilities while 902 contains the technical specifications for dining surfaces. If a transient lodging facility contains a restaurant, the restaurant must comply with requirements in other chapters such as those applicable to certain dining surfaces. 802 WHEELCHAIR SPACES, COMPANION SEATS, AND DESIGNATED AISLE SEATS 802.1 Wheelchair Spaces. Wheelchair spaces shall comply with 802.1. 802.1.1 Floor or Ground Surface. The floor or ground surface of wheelchair spaces shall comply with 302. Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted. 802.1.2 Width. A single wheelchair space shall be 36 inches (915 mm) wide minimum. Where two adjacent wheelchair spaces are provided, each wheelchair space shall be 33 inches (840 mm) wide minimum. FIGURE 802.1.2 WIDTH OF WHEELCHAIR SPACES IN ASSEMBLY AREAS 802.1.3 Depth. Where a wheelchair space can be entered from the front or rear, the wheelchair space shall be 48 inches (1220 mm) deep minimum. Where a wheelchair space can be entered only from the side, the wheelchair space shall be 60 inches (1525 mm) deep minimum. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 141 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 8: SPECIAL ROOMS, SPACES AND ELEMENTS TECHNICAL FIGURE 802.1.3 DEPTH OF WHEELCHAIR SPACES IN ASSEMBLY AREAS 802.1.4 Approach. Wheelchair spaces shall adjoin accessible routes. Accessible routes shall not overlap wheelchair spaces. Advisory 802.1.4 Approach. Because accessible routes serving wheelchair spaces are not permitted to overlap the clear floor space at wheelchair spaces, access to any wheelchair space cannot be through another wheelchair space. 802.1.5 Overlap. Wheelchair spaces shall not overlap circulation paths. Advisory 802.1.5 Overlap. The term “circulation paths” used in Section 802.1.5 means aisle width required by applicable building or life safety codes for the specific assembly occupancy. Where the circulation path provided is wider than the required aisle width, the wheelchair space may intrude into that portion of the circulation path that is provided in excess of the required aisle width. 802.2 Lines of Sight. Lines of sight to the screen, performance area, or playing field for spectators in wheelchair spaces shall comply with 802.2. 802.2.1 Lines of Sight Over Seated Spectators. Where spectators are expected to remain seated during events, spectators in wheelchair spaces shall be afforded lines of sight complying with 802.2.1. 802.2.1.1 Lines of Sight Over Heads. Where spectators are provided lines of sight over the heads of spectators seated in the first row in front of their seats, spectators seated in wheelchair spaces shall be afforded lines of sight over the heads of seated spectators in the first row in front of wheelchair spaces. FIGURE 802.2.1.1 LINES OF SIGHT OVER THE HEADS OF SEATED SPECTATORS 802.2.1.2 Lines of Sight Between Heads. Where spectators are provided lines of sight over the shoulders and between the heads of spectators seated in the first row in front of their seats, spectators seated in wheelchair spaces shall be afforded lines of sight over the shoulders and between the heads of seated spectators in the first row in front of wheelchair spaces. 142 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 TECHNICAL CHAPTER 8: SPECIAL ROOMS, SPACES AND ELEMENTS FIGURE 802.2.1.2 LINES OF SIGHT BETWEEN THE HEADS OF SEATED SPECTATORS 802.2.2 Lines of Sight Over Standing Spectators. Where spectators are expected to stand during events, spectators in wheelchair spaces shall be afforded lines of sight complying with 802.2.2. 802.2.2.1 Lines of Sight Over Heads. Where standing spectators are provided lines of sight over the heads of spectators standing in the first row in front of their seats, spectators seated in wheelchair spaces shall be afforded lines of sight over the heads of standing spectators in the first row in front of wheelchair spaces. FIGURE 802.2.2.1 LINES OF SIGHT OVER THE HEADS OF STANDING SPECTATORS 802.2.2.2 Lines of Sight Between Heads. Where standing spectators are provided lines of sight over the shoulders and between the heads of spectators standing in the first row in front of their seats, spectators seated in wheelchair spaces shall be afforded lines of sight over the shoulders and between the heads of standing spectators in the first row in front of wheelchair spaces. FIGURE 802.2.2.2 LINES OF SIGHT BETWEEN THE HEADS OF STANDING SPECTATORS 802.3 Companion Seats. Companion seats shall comply with 802.3. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 143 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 8: SPECIAL ROOMS, SPACES AND ELEMENTS TECHNICAL 802.3.1 Alignment. In row seating, companion seats shall be located to provide shoulder alignment with adjacent wheelchair spaces. The shoulder alignment point of the wheelchair space shall be measured 36 inches (915 mm) from the front of the wheelchair space. The floor surface of the companion seat shall be at the same elevation as the floor surface of the wheelchair space. 802.3.2 Type. Companion seats shall be equivalent in size, quality, comfort, and amenities to the seating in the immediate area. Companion seats shall be permitted to be movable. 802.4 Designated Aisle Seats. Designated aisle seats shall comply with 802.4. 802.4.1 Armrests. Where armrests are provided on the seating in the immediate area, folding or retractable armrests shall be provided on the aisle side of the seat. 802.4.2 Identification. Each designated aisle seat shall be identified by a sign or marke Advisory 802.4.2 Identification. Seats with folding or retractable armrests are intended for use by individuals who have difficulty walking. Consider identifying such seats with signs that contrast (light-on-dark or dark-on-light) and that are also photo luminescent. 803 DRESSING, FITTING, AND LOCKER ROOMS 803.1 General. Dressing, fitting, and locker rooms shall comply with 803. Advisory 803.1 General. Partitions and doors should be designed to ensure people using accessible dressing and fitting rooms privacy equivalent to that afforded other users of the facility. Section 903.5 requires dressing room bench seats to be installed so that they are at the same height as a typical wheelchair seat, 17 inches (430 mm) to 19 inches (485 mm). However, wheelchair seats can be lower than dressing room benches for people of short stature or children using wheelchairs. 803.2 Turning Space. Turning space complying with 304 shall be provided within the room. 803.3 Door Swing. Doors shall not swing into the room unless a clear floor or ground space complying with 305.3 is provided beyond the arc of the door swing. 803.4 Benches. A bench complying with 903 shall be provided within the room. 803.5 Coat Hooks and Shelves. Coat hooks provided within the room shall be located within one of the reach ranges specified in 308. Shelves shall be 40 inches (1015 mm) minimum and 48 inches (1220 mm) maximum above the finish floor or ground. 804 KITCHENS AND KITCHENETTES 804.1 General. Kitchens and kitchenettes shall comply with 804. 804.2 Clearance. Where a pass through kitchen is provided, clearances shall comply with 804.2.1. Where a Ushaped kitchen is provided, clearances shall comply with 804.2.2. EXCEPTION: Spaces that do not provide a cooktop or conventional range shall not be required to comply with 804.2. Advisory 804.2 Clearance. Clearances are measured from the furthest projecting face of all opposing base cabinets, counter tops, appliances, or walls, excluding hardware. 804.2.1 Pass Through Kitchen. In pass through kitchens where counters, appliances or cabinets are on two opposing sides, or where counters, appliances or cabinets are opposite a parallel wall, clearance between all opposing base cabinets, counter tops, appliances, or walls within kitchen work areas shall be 40 inches (1015 mm) minimum. Pass through kitchens shall have two entries. 144 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 TECHNICAL CHAPTER 8: SPECIAL ROOMS, SPACES AND ELEMENTS FIGURE 804.2.1 PASS THROUGH KITCHENS 804.2.2 U-Shaped. In U-shaped kitchens enclosed on three contiguous sides, clearance between all opposing base cabinets, counter tops, appliances, or walls within kitchen work areas shall be 60 inches (1525 mm) minimum. FIGURE 804.2.2 U-SHAPED KITCHENS 804.3 Kitchen Work Surface. In residential dwelling units required to comply with 809, at least one 30 inches (760 mm) wide minimum section of counter shall provide a kitchen work surface that complies with 804.3. 804.3.1 Clear Floor or Ground Space. A clear floor space complying with 305 positioned for a forward approach shall be provided. The clear floor or ground space shall be centered on the kitchen work surface and shall provide knee and toe clearance complying with 306. EXCEPTION: Cabinetry shall be permitted under the kitchen work surface provided that all of the following conditions are met: a. the cabinetry can be removed without removal or replacement of the kitchen work surface; b. the finish floor extends under the cabinetry; and c. the walls behind and surrounding the cabinetry are finished. 804.3.2 Height. The kitchen work surface shall be 34 inches (865 mm) maximum above the finish floor or ground. EXCEPTION: A counter that is adjustable to provide a kitchen work surface at variable heights, 29 inches (735 mm) minimum and 36 inches (915 mm) maximum, shall be permitted. 804.3.3 Exposed Surfaces. There shall be no sharp or abrasive surfaces under the work surface counters. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 145 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 8: SPECIAL ROOMS, SPACES AND ELEMENTS TECHNICAL 804.4 Sinks. Sinks shall comply with 606. 804.5 Storage. At least 50 percent of shelf space in storage facilities shall comply with 811. 804.6 Appliances. Where provided, kitchen appliances shall comply with 804.6. 804.6.1 Clear Floor or Ground Space. A clear floor or ground space complying with 305 shall be provided at each kitchen appliance. Clear floor or ground spaces shall be permitted to overlap. 804.6.2 Operable Parts. All appliance controls shall comply with 309. EXCEPTIONS: 1. Appliance doors and door latching devices shall not be required to comply with 309.4. 2. Bottom-hinged appliance doors, when in the open position, shall not be required to comply with 309.3. 804.6.3 Dishwasher. Clear floor or ground space shall be positioned adjacent to the dishwasher door. The dishwasher door, in the open position, shall not obstruct the clear floor or ground space for the dishwasher or the sink. 804.6.4 Range or Cooktop. Where a forward approach is provided, the clear floor or ground space shall provide knee and toe clearance complying with 306. Where knee and toe space is provided, the underside of the range or cooktop shall be insulated or otherwise configured to prevent burns, abrasions, or electrical shock. The location of controls shall not require reaching across burners. 804.6.5 Oven. Ovens shall comply with 804.6.5. 804.6.5.1 Side-Hinged Door Ovens. Side-hinged door ovens shall have the work surface required by 804.3 positioned adjacent to the latch side of the oven door. 804.6.5.2 Bottom-Hinged Door Ovens. Bottom-hinged door ovens shall have the work surface required by 804.3 positioned adjacent to one side of the door. 804.6.5.3 Controls. Ovens shall have controls on front panels. 804.6.6 Refrigerator/Freezer. Combination refrigerators and freezers shall have at least 50 percent of the freezer space 54 inches (1370 mm) maximum above the finish floor or ground. The clear floor or ground space shall be positioned for a parallel approach to the space dedicated to a refrigerator/freezer with the centerline of the clear floor or ground space offset 24 inches (610 mm) maximum from the centerline of the dedicated space. 805 MEDICAL CARE AND LONG-TERM CARE FACILITIES 805.1 General. Medical care facility and long-term care facility patient or resident sleeping rooms required to provide mobility features shall comply with 805. 805.2 Turning Space. Turning space complying with 304 shall be provided within the room. 805.3 Clear Floor or Ground Space. A clear floor space complying with 305 shall be provided on each side of the bed. The clear floor space shall be positioned for parallel approach to the side of the bed. 805.4 Toilet and Bathing Rooms. Toilet and bathing rooms that are provided as part of a patient or resident sleeping room shall comply with 603. Where provided, no fewer than one water closet, one lavatory, and one bathtub or shower shall comply with the applicable requirements of 603 through 610. 806 TRANSIENT LODGING GUEST ROOMS 806.1 General. Transient lodging guest rooms shall comply with 806. Guest rooms required to provide mobility features shall comply with 806.2. Guest rooms required to provide communication features shall comply with 806.3. All buildings, structures, or facilities licensed as a hotel, motel or condominium pursuant to chapter 509, F.S., shall comply with 806.4. 806.2 Guest Rooms with Mobility Features. Guest rooms required to provide mobility features shall comply with 806.2. 146 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 TECHNICAL CHAPTER 8: SPECIAL ROOMS, SPACES AND ELEMENTS Advisory 806.2 Guest Rooms. The requirements in Section 806.2 do not include requirements that are common to all accessible spaces. For example, closets in guest rooms must comply with the applicable provisions for storage specified in scoping. 806.2.1 Living and Dining Areas. Living and dining areas shall be accessible. 806.2.2 Exterior Spaces. Exterior spaces, including patios, terraces and balconies, that serve the guest room shall be accessible. 806.2.3 Sleeping Areas. At least one sleeping area shall provide a clear floor space complying with 305 on both sides of a bed. The clear floor space shall be positioned for parallel approach to the side of the bed. EXCEPTION: Where a single clear floor space complying with 305 positioned for parallel approach is provided between two beds, a clear floor or ground space shall not be required on both sides of a bed. 806.2.4 Toilet and Bathing Facilities. At least one bathroom that is provided as part of a guest room shall comply with 603. No fewer than one water closet, one lavatory, and one bathtub or shower shall comply with applicable requirements of 603 through 610. In addition, required roll-in shower compartments shall comply with 608.2.2 or 608.2.3. Toilet and bathing fixtures required to comply with 603 through 610 shall be permitted to be located in more than one toilet or bathing area, provided that travel between fixtures does not require travel between other parts of the guest room. 806.2.4.1 Vanity Counter Top Space. If vanity counter top space is provided in non-accessible guest toilet or bathing rooms, comparable vanity counter top space, in terms of size and proximity to the lavatory, shall also be provided in accessible guest toilet or bathing rooms. Advisory 806.2.4.1 Vanity Counter Top Space. This provision is intended to ensure that accessible guest rooms are provided with comparable vanity counter top space. 806.2.5 Kitchens and Kitchenettes. Kitchens and kitchenettes shall comply with 804. 806.2.6 Turning Space. Turning space complying with 304 shall be provided within the guest room. 806.3 Guest Rooms with Communication Features. Guest rooms required to provide communication features shall comply with 806.3. Advisory 806.3 Guest Rooms with Communication Features. In guest rooms required to have accessible communication features, consider ensuring compatibility with adaptive equipment used by people with hearing impairments. To ensure communication within the facility, as well as on commercial lines, provide telephone interface jacks that are compatible with both digital and analog signal use. If an audio headphone jack is provided on a speaker phone, a cutoff switch can be included in the jack so that insertion of the jack cuts off the speaker. If a telephone-like handset is used, the external speakers can be turned off when the handset is removed from the cradle. For headset or external amplification system compatibility, a standard subminiature jack installed in the telephone will provide the most flexibility. 806.3.1 Alarms. Where emergency warning systems are provided, alarms complying with 702 shall be provided. 806.3.2 Notification Devices. Visible notification devices shall be provided to alert room occupants of incoming telephone calls and a door knock or bell. Notification devices shall not be connected to visible alarm signal appliances. Telephones shall have volume controls compatible with the telephone system and shall comply with 704.3. Telephones shall be served by an electrical outlet complying with 309 located within 48 inches (1220 mm) of the telephone to facilitate the use of a TTY. 806.4 Hotel, Motel and Condominium Special Accessibility Features. This section does not relieve the owner of the responsibility of providing accessible rooms in conformance with Section 224 and 806 of this code. In all buildings, structures and facilities licensed as a hotel, motel or resort condominium pursuant to Chapter 509, F.S., a number of rooms equaling at least 5 percent of the guest rooms minus the Total Number of Required (accessible) Rooms required by Table 224.2 shall provide the following additional special accessibility features: (i) Grab rails in bathrooms and toilet rooms which comply with Section 604.5. (ii)All beds in designed accessible guest rooms shall be open-frame type that allows the passage of lift devices. (iii)Water closets that comply with section 604.4. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 147 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 8: SPECIAL ROOMS, SPACES AND ELEMENTS TECHNICAL 807 HOLDING CELLS AND HOUSING CELLS 807.1 General. Holding cells and housing cells shall comply with 807. 807.2 Cells with Mobility Features. Cells required to provide mobility features shall comply with 807.2. 807.2.1 Turning Space. Turning space complying with 304 shall be provided within the cell. 807.2.2 Benches. Where benches are provided, at least one bench shall comply with 903. 807.2.3 Beds. Where beds are provided, clear floor space complying with 305 shall be provided on at least one side of the bed. The clear floor space shall be positioned for parallel approach to the side of the bed. 807.2.4 Toilet and Bathing Facilities. Toilet facilities or bathing facilities that are provided as part of a cell shall comply with 603. Where provided, no fewer than one water closet, one lavatory, and one bathtub or shower shall comply with the applicable requirements of 603 through 610. Advisory 807.2.4 Toilet and Bathing Facilities. In holding cells, housing cells, or rooms required to be accessible, these requirements do not require a separate toilet room. 807.3 Cells with Communication Features. Cells required to provide communication features shall comply with 807.3. 807.3.1 Alarms. Where audible emergency alarm systems are provided to serve the occupants of cells, visible alarms complying with 702 shall be provided. EXCEPTION: Visible alarms shall not be required where inmates or detainees are not allowed independent means of egress. 807.3.2 Telephones. Telephones, where provided within cells, shall have volume controls complying with 704.3. 808 COURTROOMS 808.1 General. Courtrooms shall comply with 808. 808.2 Turning Space. Where provided, areas that are raised or depressed and accessed by ramps or platform lifts with entry ramps shall provide unobstructed turning space complying with 304. 808.3 Clear Floor Space. Each jury box and witness stand shall have, within its defined area, clear floor space complying with 305. EXCEPTION: In alterations, wheelchair spaces are not required to be located within the defined area of raised jury boxes or witness stands and shall be permitted to be located outside these spaces where ramp or platform lift access poses a hazard by restricting or projecting into a means of egress required by the appropriate administrative authority. 808.4 Judges’ Benches and Courtroom Stations. Judges’ benches, clerks’ stations, bailiffs’ stations, deputy clerks’ stations, court reporters’ stations and litigants’ and counsel stations shall comply with 902. 809 RESIDENTIAL DWELLING UNITS 809.1 General. Residential dwelling units shall comply with 809. Residential dwelling units required to provide mobility features shall comply with 809.2 through 809.4. Residential dwelling units required to provide communication features shall comply with 809.5. 809.2 Accessible Routes. Accessible routes complying with Chapter 4 shall be provided within residential dwelling units in accordance with 809.2. EXCEPTION: Accessible routes shall not be required to or within unfinished attics or unfinished basements. 809.2.1 Location. At least one accessible route shall connect all spaces and elements which are a part of the residential dwelling unit. Where only one accessible route is provided, it shall not pass through bathrooms, closets, or similar spaces. 148 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 TECHNICAL CHAPTER 8: SPECIAL ROOMS, SPACES AND ELEMENTS 809.2.2 Turning Space. All rooms served by an accessible route shall provide a turning space complying with 304. EXCEPTION: Turning space shall not be required in exterior spaces 30 inches (760 mm) maximum in depth or width. Advisory 809.2.2 Turning Space. It is generally acceptable to use required clearances to provide wheelchair turning space. For example, in kitchens, 804.3.1 requires at least one work surface with clear floor space complying with 306 to be centered beneath. If designers elect to provide clear floor space that is at least 36 inches (915 mm) wide, as opposed to the required 30 inches (760 mm) wide, that clearance can be part of a T-turn, thereby maximizing efficient use of the kitchen area. However, the overlap of turning space must be limited to one segment of the T-turn so that back-up maneuvering is not restricted. It would, therefore, be unacceptable to use both the clearances under the work surface and the sink as part of a T-turn. See Section 304.3.2 regarding T-turns. 809.3 Kitchen. Where a kitchen is provided, it shall comply with 804. 809.4 Toilet Facilities and Bathing Facilities. At least one bathroom shall comply with 603. No fewer than one of each type of fixture provided shall comply with applicable requirements of 603 through 610. Toilet and bathing fixtures required to comply with 603 through 610 shall be located in the same toilet and bathing area, such that travel between fixtures does not require travel between other parts of the residential dwelling unit. Advisory 809.4 Toilet Facilities and Bathing Facilities. In an effort to promote space efficiency, vanity counter top space in accessible residential dwelling units is often omitted. This omission does not promote equal access or equal enjoyment of the unit. Where comparable units have vanity counter tops, accessible units should also have vanity counter tops located as close as possible to the lavatory for convenient access to toiletries. 809.5 Residential Dwelling Units with Communication Features. Residential dwelling units required to provide communication features shall comply with 809.5. 809.5.1 Building Fire Alarm System. Where a building fire alarm system is provided, the system wiring shall be extended to a point within the residential dwelling unit in the vicinity of the residential dwelling unit smoke detection system. 809.5.1.1 Alarm Appliances. Where alarm appliances are provided within a residential dwelling unit as part of the building fire alarm system, they shall comply with 702. 809.5.1.2 Activation. All visible alarm appliances provided within the residential dwelling unit for building fire alarm notification shall be activated upon activation of the building fire alarm in the portion of the building containing the residential dwelling unit. 809.5.2 Residential Dwelling Unit Smoke Detection System. Residential dwelling unit smoke detection systems shall comply with NFPA 72 (1999 or 2002 edition) (incorporated by reference, see “Referenced Standards” in Chapter 1). 809.5.2.1 Activation. All visible alarm appliances provided within the residential dwelling unit for smoke detection notification shall be activated upon smoke detection. 809.5.3 Interconnection. The same visible alarm appliances shall be permitted to provide notification of residential dwelling unit smoke detection and building fire alarm activation. 809.5.4 Prohibited Use. Visible alarm appliances used to indicate residential dwelling unit smoke detection or building fire alarm activation shall not be used for any other purpose within the residential dwelling unit. 809.5.5 Residential Dwelling Unit Primary Entrance. Communication features shall be provided at the residential dwelling unit primary entrance complying with 809.5.5. 809.5.5.1 Notification. A hard-wired electric doorbell shall be provided. A button or switch shall be provided outside the residential dwelling unit primary entrance. Activation of the button or switch shall initiate an audible tone and visible signal within the residential dwelling unit. Where visible doorbell signals are located in sleeping areas, they shall have controls to deactivate the signal. 809.5.5.2 Identification. A means for visually identifying a visitor without opening the residential dwelling unit entry door shall be provided and shall allow for a minimum 180 degree range of view. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 149 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 8: SPECIAL ROOMS, SPACES AND ELEMENTS TECHNICAL Advisory 809.5.5.2 Identification. In doors, peepholes that include prisms clarify the image and should offer a wide-angle view of the hallway or exterior for both standing persons and wheelchair users. Such peepholes can be placed at a standard height and permit a view from several feet from the door. 809.5.6 Site, Building, or Floor Entrance. Where a system, including a closed-circuit system, permitting voice communication between a visitor and the occupant of the residential dwelling unit is provided, the system shall comply with 708.4. 810 TRANSPORTATION FACILITIES 810.1 General. Transportation facilities shall comply with 810. 810.2 Bus Boarding and Alighting Areas. Bus boarding and alighting areas shall comply with 810.2. Advisory 810.2 Bus Boarding and Alighting Areas. At bus stops where a shelter is provided, the bus stop pad can be located either within or outside of the shelter. 810.2.1 Surface. Bus stop boarding and alighting areas shall have a firm, stable surface. 810.2.2 Dimensions. Bus stop boarding and alighting areas shall provide a clear length of 96 inches (2440 mm) minimum, measured perpendicular to the curb or vehicle roadway edge, and a clear width of 60 inches (1525 mm) minimum, measured parallel to the vehicle roadway. FIGURE 810.2.2 DIMENSIONS OF BUS BOARDING AND ALIGHTING AREAS 810.2.3 Connection. Bus stop boarding and alighting areas shall be connected to streets, sidewalks, or pedestrian paths by an accessible route complying with 402. 810.2.4 Slope. Parallel to the roadway, the slope of the bus stop boarding and alighting area shall be the same as the roadway, to the maximum extent practicable. Perpendicular to the roadway, the slope of the bus stop boarding and alighting area shall not be steeper than 1:48. 810.3 Bus Shelters. Bus shelters shall provide a minimum clear floor or ground space complying with 305 entirely within the shelter. Bus shelters shall be connected by an accessible route complying with 402 to a boarding and alighting area complying with 810.2. 150 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 TECHNICAL CHAPTER 8: SPECIAL ROOMS, SPACES AND ELEMENTS FIGURE 810.3 BUS SHELTERS 810.4 Bus Signs. Bus route identification signs shall comply with 703.5.1 through 703.5.4, and 703.5.7 and 703.5.8. In addition, to the maximum extent practicable, bus route identification signs shall comply with 703.5.5. EXCEPTION: Bus schedules, timetables and maps that are posted at the bus stop or bus bay shall not be required to comply. 810.5 Rail Platforms. Rail platforms shall comply with 810.5. 810.5.1 Slope. Rail platforms shall not exceed a slope of 1:48 in all directions. EXCEPTION: Where platforms serve vehicles operating on existing track or track laid in existing roadway, the slope of the platform parallel to the track shall be permitted to be equal to the slope (grade) of the roadway or existing track. 810.5.2 Detectable Warnings. Platform boarding edges not protected by platform screens or guards shall have detectable warnings complying with 705 along the full length of the public use area of the platform. 810.5.3 Platform and Vehicle Floor Coordination. Station platforms shall be positioned to coordinate with vehicles in accordance with the applicable requirements of 36 CFR Part 1192. Low-level platforms shall be 8 inches (205 mm) minimum above top of rail. In light rail, commuter rail, and intercity rail systems subject to Department of Transportation regulation 49 CFR 37.21 where it is not operationally or structurally feasible to meet the horizontal gap or vertical difference requirements of part 1192 or 49 CFR part 38, mini-high platforms, carborne or platform-mounted lifts, ramps or bridge plates or similarly manually deployed devices, meeting the requirements of 49 CFR part 38, shall suffice. EXCEPTION: Where vehicles are boarded from sidewalks or street-level, low-level platforms shall be permitted to be less than 8 inches (205 mm). Advisory 810.5.3 Platform and Vehicle Floor Coordination. The height and position of a platform must be coordinated with the floor of the vehicles it serves to minimize the vertical and horizontal gaps, in accordance with the ADA Accessibility Guidelines for Transportation Vehicles (36 CFR Part 1192). The vehicle guidelines, divided by bus, van, light rail, rapid rail, commuter rail, intercity rail, are available at www.access-board.gov. The preferred alignment is a high platform, level with the vehicle floor. In some cases, the vehicle guidelines permit use of a low platform in conjunction with a lift or ramp. Most such low platforms must have a minimum height of eight inches above the top of the rail. Some vehicles are designed to be boarded from a street or the sidewalk along the street and the exception permits such boarding areas to be less than eight inches high. 810.6 Rail Station Signs. Rail station signs shall comply with 810.6. EXCEPTION: Signs shall not be required to comply with 810.6.1 and 810.6.2 where audible signs are remotely transmitted to hand-held receivers, or are user- or proximity-actuated. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 151 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 8: SPECIAL ROOMS, SPACES AND ELEMENTS TECHNICAL Advisory 810.6 Rail Station Signs Exception. Emerging technologies such as an audible sign system using infrared transmitters and receivers may provide greater accessibility in the transit environment than traditional Braille and raised letter signs. The transmitters are placed on or next to print signs and transmit their information to an infrared receiver that is held by a person. By scanning an area, the person will hear the sign. This means that signs can be placed well out of reach of Braille readers, even on parapet walls and on walls beyond barriers. Additionally, such signs can be used to provide way-finding information that cannot be efficiently conveyed on Braille signs. 810.6.1 Entrances. Where signs identify a station or its entrance, at least one sign at each entrance shall comply with 703.2 and shall be placed in uniform locations to the maximum extent practicable. Where signs identify a station that has no defined entrance, at least one sign shall comply with 703.2 and shall be placed in a central location. 810.6.2 Routes and Destinations. Lists of stations, routes and destinations served by the station which are located on boarding areas, platforms, or mezzanines shall comply with 703.5. At least one tactile sign identifying the specific station and complying with 703.2 shall be provided on each platform or boarding area. Signs covered by this requirement shall, to the maximum extent practicable, be placed in uniform locations within the system. EXCEPTION: Where sign space is limited, characters shall not be required to exceed 3 inches (75 mm). Advisory 810.6.2 Routes and Destinations. Route maps are not required to comply with the informational sign requirements in this code. 810.6.3 Station Names. Stations covered by this section shall have identification signs complying with 703.5. Signs shall be clearly visible and within the sight lines of standing and sitting passengers from within the vehicle on both sides when not obstructed by another vehicle. Advisory 810.6.3 Station Names. It is also important to place signs at intervals in the station where passengers in the vehicle will be able to see a sign when the vehicle is either stopped at the station or about to come to a stop in the station. The number of signs necessary may be directly related to the size of the lettering displayed on the sign. 810.7 Public Address Systems. Where public address systems convey audible information to the public, the same or equivalent information shall be provided in a visual format. 810.8 Clocks. Where clocks are provided for use by the public, the clock face shall be uncluttered so that its elements are clearly visible. Hands, numerals and digits shall contrast with the background either light-on-dark or dark-on-light. Where clocks are installed overhead, numerals and digits shall comply with 703.5. 810.9 Escalators. Where provided, escalators shall comply with the sections 6.1.3.5.6 and 6.1.3.6.5 of ASME A17.1 (incorporated by reference, see “Referenced Standards” in Chapter 1) and shall have a clear width of 32 inches (815 mm) minimum. EXCEPTION: Existing escalators in key stations shall not be required to comply with 810.9. 810.10 Track Crossings. Where a circulation path serving boarding platforms crosses tracks, it shall comply with 402. EXCEPTION: Openings for wheel flanges shall be permitted to be 21/2 inches (64 mm) maximum. FIGURE 810.10 (EXCEPTION) TRACK CROSSINGS 152 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 TECHNICAL CHAPTER 8: SPECIAL ROOMS, SPACES AND ELEMENTS 811 STORAGE 811.1 General. Storage shall comply with 811. 811.2 Clear Floor or Ground Space. A clear floor or ground space complying with 305 shall be provided. 811.3 Height. Storage elements shall comply with at least one of the reach ranges specified in 308. 811.4 Operable Parts. Operable parts shall comply with 309. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 153 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 154 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 9: BUILT-IN ELEMENTS 901 GENERAL 901.1 Scope. The provisions of Chapter 9 shall apply where required by Chapter 2 or where referenced by a requirement in this code. 902 DINING SURFACES AND WORK SURFACES 902.1 General. Dining surfaces and work surfaces shall comply with 902.2 and 902.3. EXCEPTION: Dining surfaces and work surfaces for children’s use shall be permitted to comply with 902.4. Advisory 902.1 General. Dining surfaces include, but are not limited to, bars, tables, lunch counters, and booths. Examples of work surfaces include writing surfaces, study carrels, student laboratory stations, baby changing and other tables or fixtures for personal grooming, coupon counters, and where covered by the ABA scoping provisions, employee work stations. 902.2 Clear Floor or Ground Space. A clear floor space complying with 305 positioned for a forward approach shall be provided. Knee and toe clearance complying with 306 shall be provided. 902.3 Height. The tops of dining surfaces and work surfaces shall be 28 inches (710 mm) minimum and 34 inches (865 mm) maximum above the finish floor or ground. 902.4 Dining Surfaces and Work Surfaces for Children’s Use. Accessible dining surfaces and work surfaces for children’s use shall comply with 902.4. EXCEPTION: Dining surfaces and work surfaces that are used primarily by children 5 years and younger shall not be required to comply with 902.4 where a clear floor or ground space complying with 305 positioned for a parallel approach is provided. 902.4.1 Clear Floor or Ground Space. A clear floor space complying with 305 positioned for forward approach shall be provided. Knee and toe clearance complying with 306 shall be provided, except that knee clearance 24 inches (610 mm) minimum above the finish floor or ground shall be permitted. 902.4.2 Height. The tops of tables and counters shall be 26 inches (660 mm) minimum and 30 inches (760 mm) maximum above the finish floor or ground. 903 BENCHES 903.1 General. Benches shall comply with 903. 903.2 Clear Floor or Ground Space. Clear floor or ground space complying with 305 shall be provided and shall be positioned at the end of the bench seat and parallel to the short axis of the bench. 903.3 Size. Benches shall have seats that are 42 inches (1065 mm) long minimum and 20 inches (510 mm) deep minimum and 24 inches (610 mm) deep maximum. 903.4 Back Support. The bench shall provide for back support or shall be affixed to a wall. Back support shall be 42 inches (1065 mm) long minimum and shall extend from a point 2 inches (51 mm) maximum above the seat surface to a point 18 inches (455 mm) minimum above the seat surface. Back support shall be 21/2 inches (64 mm) maximum from the rear edge of the seat measured horizontally. Advisory 903.4 Back Support. To assist in transferring to the bench, consider providing grab bars on a wall adjacent to the bench, but not on the seat back. If provided, grab bars cannot obstruct transfer to the bench. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 155 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 9: BUILT-IN ELEMENTS TECHNICAL FIGURE 903.4 BENCH BACK SUPPORT 903.5 Height. The top of the bench seat surface shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum above the finish floor or ground. 903.6 Structural Strength. Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the seat, fastener, mounting device, or supporting structure. 903.7 Wet Locations. Where installed in wet locations, the surface of the seat shall be slip resistant and shall not accumulate water. 904 CHECK-OUT AISLES AND SALES AND SERVICE COUNTERS 904.1 General. Check-out aisles and sales and service counters shall comply with the applicable requirements of 904. 904.2 Approach. All portions of counters required to comply with 904 shall be located adjacent to a walking surface complying with 403. Advisory 904.2 Approach. If a cash register is provided at the sales or service counter, locate the accessible counter close to the cash register so that a person using a wheelchair is visible to sales or service personnel and to minimize the reach for a person with a disability. 904.3 Check-Out Aisles. Check-out aisles shall comply with 904.3. 904.3.1 Aisle. Aisles shall comply with 403. 904.3.2 Counter. The counter surface height shall be 38 inches (965 mm) maximum above the finish floor or ground. The top of the counter edge protection shall be 2 inches (51 mm) maximum above the top of the counter surface on the aisle side of the check-out counter. FIGURE 904.3.2 CHECK-OUT AISLE COUNTERS 904.3.3 Check Writing Surfaces. Where provided, check writing surfaces shall comply with 902.3. 156 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 TECHNICAL CHAPTER 9: BUILT-IN ELEMENTS 904.4 Sales and Service Counters. Sales counters and service counters shall comply with 904.4.1 or 904.4.2. The accessible portion of the counter top shall extend the same depth as the sales or service counter top. EXCEPTION: In alterations, when the provision of a counter complying with 904.4 would result in a reduction of the number of existing counters at work stations or a reduction of the number of existing mail boxes, the counter shall be permitted to have a portion which is 24 inches (610 mm) long minimum complying with 904.4.1 provided that the required clear floor or ground space is centered on the accessible length of the counter. FIGURE 904.4 (EXCEPTION) ALTERATION OF SALES AND SERVICE COUNTERS 904.4.1 Parallel Approach. A portion of the counter surface that is 36 inches (915 mm) long minimum and 36 inches (915 mm) high maximum above the finish floor shall be provided. A clear floor or ground space complying with 305 shall be positioned for a parallel approach adjacent to the 36 inch (915 mm) minimum length of counter. EXCEPTION: Where the provided counter surface is less than 36 inches (915 mm) long, the entire counter surface shall be 36 inches (915 mm) high maximum above the finish floor. 904.4.2 Forward Approach. A portion of the counter surface that is 30 inches (760 mm) long minimum and 36 inches (915 mm) high maximum shall be provided. Knee and toe space complying with 306 shall be provided under the counter. A clear floor or ground space complying with 305 shall be positioned for a forward approach to the counter. 904.5 Food Service Lines. Counters in food service lines shall comply with 904.5. 904.5.1 Self-Service Shelves and Dispensing Devices. Self-service shelves and dispensing devices for tableware, dishware, condiments, food and beverages shall comply with 308. 904.5.2 Tray Slides. The tops of tray slides shall be 28 inches (710 mm) minimum and 34 inches (865 mm) maximum above the finish floor or ground. 904.6 Security Glazing. Where counters or teller windows have security glazing to separate personnel from the public, a method to facilitate voice communication shall be provided. Telephone handset devices, if provided, shall comply with 704.3. Advisory 904.6 Security Glazing. Assistive listening devices complying with 706 can facilitate voice communication at counters or teller windows where there is security glazing which promotes distortion in audible information. Where assistive listening devices are installed, place signs complying with 703.7.2.4 to identify those facilities which are so equipped. Other voice communication methods include, but are not limited to, grilles, slats, talk-through baffles, intercoms, or telephone handset devices. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 157 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 158 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 10: RECREATION FACILITIES 1001 GENERAL 1001.1 Scope. The provisions of Chapter 10 shall apply where required by Chapter 2 or where referenced by a requirement in this code. Advisory 1001.1 Scope. Unless otherwise modified or specifically addressed in Chapter 10, all other ADAAG provisions apply to the design and construction of recreation facilities and elements. The provisions in Section 1001.1 apply wherever these elements are provided. For example, office buildings may contain a room with exercise equipment to which these sections would apply. 1002 AMUSEMENT RIDES 1002.1 General. Amusement rides shall comply with 1002. 1002.2 Accessible Routes. Accessible routes serving amusement rides shall comply with Chapter 4. EXCEPTIONS: 1. In load or unload areas and on amusement rides, where compliance with 405.2 is not structurally or operationally feasible, ramp slope shall be permitted to be 1:8 maximum. 2. In load or unload areas and on amusement rides, handrails provided along walking surfaces complying with 403 and required on ramps complying with 405 shall not be required to comply with 505 where compliance is not structurally or operationally feasible. Advisory 1002.2 Accessible Routes Exception 1. Steeper slopes are permitted on accessible routes connecting the amusement ride in the load and unload position where it is “structurally or operationally infeasible.” In most cases, this will be limited to areas where the accessible route leads directly to the amusement ride and where there are space limitations on the ride, not the queue line. Where possible, the least possible slope should be used on the accessible route that serves the amusement ride. 1002.3 Load and Unload Areas. A turning space complying with 304.2 and 304.3 shall be provided in load and unload areas. 1002.4 Wheelchair Spaces in Amusement Rides. Wheelchair spaces in amusement rides shall comply with 1002.4. 1002.4.1 Floor or Ground Surface. The floor or ground surface of wheelchair spaces shall be stable and firm. 1002.4.2 Slope. The floor or ground surface of wheelchair spaces shall have a slope not steeper than 1:48 when in the load and unload position. 1002.4.3 Gaps. Floors of amusement rides with wheelchair spaces and floors of load and unload areas shall be coordinated so that, when amusement rides are at rest in the load and unload position, the vertical difference between the floors shall be within plus or minus 5/8 inches (16 mm) and the horizontal gap shall be 3 inches (75 mm) maximum under normal passenger load conditions. EXCEPTION: Where compliance is not operationally or structurally feasible, ramps, bridge plates, or similar devices complying with the applicable requirements of 36 CFR 1192.83(c) shall be provided. Advisory 1002.4.3 Gaps Exception. 36 CFR 1192.83(c) ADA Accessibility Guidelines for Transportation Vehicles – Light Rail Vehicles and Systems – Mobility Aid Accessibility is available at www.access-board.gov. It includes provisions for bridge plates and ramps that can be used at gaps between wheelchair spaces and floors of load and unload areas. 1002.4.4 Clearances. Clearances for wheelchair spaces shall comply with 1002.4.4. EXCEPTIONS: 1. Where provided, securement devices shall be permitted to overlap required clearances. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 159 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 10: RECREATION FACILITIES TECHNICAL 2. Wheelchair spaces shall be permitted to be mechanically or manually repositioned. 3. Wheelchair spaces shall not be required to comply with 307.4. Advisory 1002.4.4 Clearances Exception 3. This exception for protruding objects applies to the ride devices, not to circulation areas or accessible routes in the queue lines or the load and unload areas. 1002.4.4.1 Width and Length. Wheelchair spaces shall provide a clear width of 30 inches (760 mm) minimum and a clear length of 48 inches (1220 mm) minimum measured to 9 inches (230 mm) minimum above the floor surface. 1002.4.4.2 Side Entry. Where wheelchair spaces are entered only from the side, amusement rides shall be designed to permit sufficient maneuvering clearance for individuals using a wheelchair or mobility aid to enter and exit the ride. Advisory 1002.4.4.2 Side Entry. The amount of clear space needed within the ride, and the size and position of the opening are interrelated. A 32 inch (815 mm) clear opening will not provide sufficient width when entered through a turn into an amusement ride. Additional space for maneuvering and a wider door will be needed where a side opening is centered on the ride. For example, where a 42 inch (1065 mm) opening is provided, a minimum clear space of 60 inches (1525 mm) in length and 36 inches (915 mm) in depth is needed to ensure adequate space for maneuvering. 1002.4.4.3 Permitted Protrusions in Wheelchair Spaces. Objects are permitted to protrude a distance of 6 inches (150 mm) maximum along the front of the wheelchair space, where located 9 inches (230 mm) minimum and 27 inches (685 mm) maximum above the floor or ground surface of the wheelchair space. Objects are permitted to protrude a distance of 25 inches (635 mm) maximum along the front of the wheelchair space, where located more than 27 inches (685 mm) above the floor or ground surface of the wheelchair space. FIGURE 1002.4.4.3 PROTRUSIONS IN WHEELCHAIR SPACES IN AMUSEMENT RIDES 1002.4.5 Ride Entry. Openings providing entry to wheelchair spaces on amusement rides shall be 32 inches (815 mm) minimum clear. 1002.4.6 Approach. One side of the wheelchair space shall adjoin an accessible route when in the load and unload position. 1002.4.7 Companion Seats. Where the interior width of the amusement ride is greater than 53 inches (1345 mm), seating is provided for more than one rider, and the wheelchair is not required to be centered within the amusement ride, a companion seat shall be provided for each wheelchair space. 1002.4.7.1 Shoulder-to-Shoulder Seating. Where an amusement ride provides shoulder-to-shoulder seating, companion seats shall be shoulder-to-shoulder with the adjacent wheelchair space. EXCEPTION: Where shoulder-to-shoulder companion seating is not operationally or structurally feasible, compliance with this requirement shall be required to the maximum extent practicable. 160 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 TECHNICAL CHAPTER 10: RECREATION FACILITIES 1002.5 Amusement Ride Seats Designed for Transfer. Amusement ride seats designed for transfer shall comply with 1002.5 when positioned for loading and unloading. Advisory 1002.5 Amusement Ride Seats Designed for Transfer. The proximity of the clear floor or ground space next to an element and the height of the element one is transferring to are both critical for a safe and independent transfer. Providing additional clear floor or ground space both in front of and diagonal to the element will provide flexibility and will increase usability for a more diverse population of individuals with disabilities. Ride seats designed for transfer should involve only one transfer. Where possible, designers are encouraged to locate the ride seat no higher than 17 to 19 inches (430 to 485 mm) above the load and unload surface. Where greater distances are required for transfers, providing gripping surfaces, seat padding, and avoiding sharp objects in the path of transfer will facilitate the transfer. 1002.5.1 Clear Floor or Ground Space. A clear floor or ground space complying with 305 shall be provided in the load and unload area adjacent to the amusement ride seats designed for transfer. 1002.5.2 Transfer Height. The height of amusement ride seats designed for transfer shall be 14 inches (355 mm) minimum and 24 inches (610 mm) maximum measured from the surface of the load and unload area. 1002.5.3 Transfer Entry. Where openings are provided for transfer to amusement ride seats, the openings shall provide clearance for transfer from a wheelchair or mobility aid to the amusement ride seat. 1002.5.4 Wheelchair Storage Space. Wheelchair storage spaces complying with 305 shall be provided in or adjacent to unload areas for each required amusement ride seat designed for transfer and shall not overlap any required means of egress or accessible route. 1002.6 Transfer Devices for Use with Amusement Rides. Transfer devices for use with amusement rides shall comply with 1002.6 when positioned for loading and unloading. Advisory 1002.6 Transfer Devices for Use with Amusement Rides. Transfer devices for use with amusement rides should permit individuals to make independent transfers to and from their wheelchairs or mobility devices. There are a variety of transfer devices available that could be adapted to provide access onto an amusement ride. Examples of devices that may provide for transfers include, but are not limited to, transfer systems, lifts, mechanized seats, and custom designed systems. Operators and designers have flexibility in developing designs that will facilitate individuals to transfer onto amusement rides. These systems or devices should be designed to be reliable and sturdy. Designs that limit the number of transfers required from a wheelchair or mobility device to the ride seat are encouraged. When using a transfer device to access an amusement ride, the least number of transfers and the shortest distance is most usable. Where possible, designers are encouraged to locate the transfer device seat no higher than 17 to 19 inches (430 to 485 mm) above the load and unload surface. Where greater distances are required for transfers, providing gripping surfaces, seat padding, and avoiding sharp objects in the path of transfer will facilitate the transfer. Where a series of transfers are required to reach the amusement ride seat, each vertical transfer should not exceed 8 inches (205 mm). 1002.6.1 Clear Floor or Ground Space. A clear floor or ground space complying with 305 shall be provided in the load and unload area adjacent to the transfer device. 1002.6.2 Transfer Height. The height of transfer device seats shall be 14 inches (355 mm) minimum and 24 inches (610 mm) maximum measured from the load and unload surface. 1002.6.3 Wheelchair Storage Space. Wheelchair storage spaces complying with 305 shall be provided in or adjacent to unload areas for each required transfer device and shall not overlap any required means of egress or accessible route. 1003 RECREATIONAL BOATING FACILITIES 1003.1 General. Recreational boating facilities shall comply with 1003. 1003.2 Accessible Routes. Accessible routes serving recreational boating facilities, including gangways and floating piers, shall comply with Chapter 4 except as modified by the exceptions in 1003.2. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 161 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 10: RECREATION FACILITIES TECHNICAL 1003.2.1 Boat Slips. Accessible routes serving boat slips shall be permitted to use the exceptions in 1003.2.1. EXCEPTIONS: 1. Where an existing gangway or series of gangways is replaced or altered, an increase in the length of the gangway shall not be required to comply with 1003.2 unless required by 202.4. 2. Gangways shall not be required to comply with the maximum rise specified in 405.6. 3. Where the total length of a gangway or series of gangways serving as part of a required accessible route is 80 feet (24 m) minimum, gangways shall not be required to comply with 405.2. 4. Where facilities contain fewer than 25 boat slips and the total length of the gangway or series of gangways serving as part of a required accessible route is 30 feet (9145 mm) minimum, gangways shall not be required to comply with 405.2. 5. Where gangways connect to transition plates, landings specified by 405.7 shall not be required. 6. Where gangways and transition plates connect and are required to have handrails, handrail extensions shall not be required. Where handrail extensions are provided on gangways or transition plates, the handrail extensions shall not be required to be parallel with the ground or floor surface. 7. The cross slope specified in 403.3 and 405.3 for gangways, transition plates, and floating piers that are part of accessible routes shall be measured in the static position. 8. Changes in level complying with 303.3 and 303.4 shall be permitted on the surfaces of gangways and boat launch ramps. Advisory 1003.2.1 Boat Slips Exception 3. The following example shows how exception 3 would be applied: A gangway is provided to a floating pier which is required to be on an accessible route. The vertical distance is 10 feet (3050 mm) between the elevation where the gangway departs the landside connection and the elevation of the pier surface at the lowest water level. Exception 3 permits the gangway to be 80 feet (24 m) long. Another design solution would be to have two 40 foot (12 m) plus continuous gangways joined together at a float, where the float (as the water level falls) will stop dropping at an elevation five feet below the landside connection. The length of transition plates would not be included in determining if the gangway(s) meet the requirements of the exception. 1003.2.2 Boarding Piers at Boat Launch Ramps. Accessible routes serving boarding piers at boat launch ramps shall be permitted to use the exceptions in 1003.2.2. EXCEPTIONS: 1. Accessible routes serving floating boarding piers shall be permitted to use Exceptions 1, 2, 5, 6, 7 and 8 in 1003.2.1. 2. Where the total length of the gangway or series of gangways serving as part of a required accessible route is 30 feet (9145 mm) minimum, gangways shall not be required to comply with 405.2. 3. Where the accessible route serving a floating boarding pier or skid pier is located within a boat launch ramp, the portion of the accessible route located within the boat launch ramp shall not be required to comply with 405. 1003.3 Clearances. Clearances at boat slips and on boarding piers at boat launch ramps shall comply with 1003.3. Advisory 1003.3 Clearances. Although the minimum width of the clear pier space is 60 inches (1525 mm), it is recommended that piers be wider than 60 inches (1525 mm) to improve the safety for persons with disabilities, particularly on floating piers. 1003.3.1 Boat Slip Clearance. Boat slips shall provide clear pier space 60 inches (1525 mm) wide minimum and at least as long as the boat slips. Each 10 feet (3050 mm) maximum of linear pier edge serving boat slips shall contain at least one continuous clear opening 60 inches (1525 mm) wide minimum. EXCEPTIONS: 1. Clear pier space shall be permitted to be 36 inches (915 mm) wide minimum for a length of 24 inches (610 mm) maximum, provided that multiple 36 inch (915 mm) wide segments are separated by segments that are 60 inches (1525 mm) wide minimum and 60 inches (1525 mm) long minimum. 162 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 TECHNICAL CHAPTER 10: RECREATION FACILITIES 2. Edge protection shall be permitted at the continuous clear openings, provided that it is 4 inches (100 mm) high maximum and 2 inches (51 mm) wide maximum. 3. In existing piers, clear pier space shall be permitted to be located perpendicular to the boat slip and shall extend the width of the boat slip, where the facility has at least one boat slip complying with 1003.3, and further compliance with 1003.3 would result in a reduction in the number of boat slips available or result in a reduction of the widths of existing slips. Advisory 1003.3.1 Boat Slip Clearance Exception 3. Where the conditions in exception 3 are satisfied, existing facilities are only required to have one accessible boat slip with a pier clearance which runs the length of the slip. All other accessible slips are allowed to have the required pier clearance at the head of the slip. Under this exception, at piers with perpendicular boat slips, the width of most “finger piers” will remain unchanged. However, where mooring systems for floating piers are replaced as part of pier alteration projects, an opportunity may exist for increasing accessibility. Piers may be reconfigured to allow an increase in the number of wider finger piers, and serve as accessible boat slips. FIGURE 1003.3.1 BOAT SLIP CLEARANCE FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 163 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 10: RECREATION FACILITIES TECHNICAL FIGURE 1003.3.1 (EXCEPTION 1) CLEAR PIER SPACE REDUCTION AT BOAT SLIPS FIGURE 1003.3.1 (EXCEPTION 2) EDGE PROTECTION AT BOAT SLIPS 1003.3.2 Boarding Pier Clearances. Boarding piers at boat launch ramps shall provide clear pier space 60 inches (1525 mm) wide minimum and shall extend the full length of the boarding pier. Every 10 feet (3050 mm) maximum of linear pier edge shall contain at least one continuous clear opening 60 inches (1525 mm) wide minimum. EXCEPTIONS: 1. The clear pier space shall be permitted to be 36 inches (915 mm) wide minimum for a length of 24 inches (610 mm) maximum provided that multiple 36 inch (915 mm) wide segments are separated by segments that are 60 inches (1525 mm) wide minimum and 60 inches (1525 mm) long minimum. 2. Edge protection shall be permitted at the continuous clear openings provided that it is 4 inches (100 mm) high maximum and 2 inches (51 mm) wide maximum. 164 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 TECHNICAL CHAPTER 10: RECREATION FACILITIES Advisory 1003.3.2 Boarding Pier Clearances. These requirements do not establish a minimum length for accessible boarding piers at boat launch ramps. The accessible boarding pier should have a length at least equal to that of other boarding piers provided at the facility. If no other boarding pier is provided, the pier would have a length equal to what would have been provided if no access requirements applied. The entire length of accessible boarding piers would be required to comply with the same technical provisions that apply to accessible boat slips. For example, at a launch ramp, if a 20 foot (6100 mm) long accessible boarding pier is provided, the entire 20 feet (6100 mm) must comply with the pier clearance requirements in 1003.3. Likewise, if a 60 foot (18 m) long accessible boarding pier is provided, the pier clearance requirements in 1003.3 would apply to the entire 60 feet (18 m). The following example applies to a boat launch ramp boarding pier: A chain of floats is provided on a launch ramp to be used as a boarding pier which is required to be accessible by 1003.3.2. At high water, the entire chain is floating and a transition plate connects the first float to the surface of the launch ramp. As the water level decreases, segments of the chain end up resting on the launch ramp surface, matching the slope of the launch ramp. FIGURE 1003.3.2 BOARDING PIER CLEARANCE FIGURE 1003.3.2 (EXCEPTION 1) CLEAR PIER SPACE REDUCTION AT BOARDING PIERS FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 165 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 10: RECREATION FACILITIES TECHNICAL FIGURE 1003.3.2 (EXCEPTION 2) EDGE PROTECTION AT BOARDING PIERS 1004 EXERCISE MACHINES AND EQUIPMENT 1004.1 Clear Floor Space. Exercise machines and equipment shall have a clear floor space complying with 305 positioned for transfer or for use by an individual seated in a wheelchair. Clear floor or ground spaces required at exercise machines and equipment shall be permitted to overlap. Advisory 1004.1 Clear Floor Space. One clear floor or ground space is permitted to be shared between two pieces of exercise equipment. To optimize space use, designers should carefully consider layout options such as connecting ends of the row and center aisle spaces. The position of the clear floor space may vary greatly depending on the use of the equipment or machine. For example, to provide access to a shoulder press machine, clear floor space next to the seat would be appropriate to allow for transfer. Clear floor space for a bench press machine designed for use by an individual seated in a wheelchair, however, will most likely be centered on the operating mechanisms. 1005 FISHING PIERS AND PLATFORMS 1005.1 Accessible Routes. Accessible routes serving fishing piers and platforms, including gangways and floating piers, shall comply with Chapter 4. EXCEPTIONS: 1. Accessible routes serving floating fishing piers and platforms shall be permitted to use Exceptions 1, 2, 5, 6, 7 and 8 in 1003.2.1. 2. Where the total length of the gangway or series of gangways serving as part of a required accessible route is 30 feet (9145 mm) minimum, gangways shall not be required to comply with 405.2. 1005.2 Railings. Where provided, railings, guards, or handrails shall comply with 1005.2. 1005.2.1 Height. At least 25 percent of the railings, guards, or handrails shall be 34 inches (865 mm) maximum above the ground or deck surface. EXCEPTION: Where a guard complying with sections 1003.2.12.1 and 1003.2.12.2 of the International Building Code (2000 edition) or sections 1012.2 and 1012.3 of the International Building Code (2003 edition) (incorporated by reference, see “Referenced Standards” in Chapter 1) is provided, the guard shall not be required to comply with 1005.2.1. 1005.2.1.1 Dispersion. Railings, guards, or handrails required to comply with 1005.2.1 shall be dispersed throughout the fishing pier or platform. Advisory 1005.2.1.1 Dispersion. Portions of the railings that are lowered to provide fishing opportunities for persons with disabilities must be located in a variety of locations on the fishing pier or platform to give people a variety of locations to fish. Different fishing locations may provide varying water depths, shade (at certain times of the day), vegetation, and proximity to the shoreline or bank. 166 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 TECHNICAL CHAPTER 10: RECREATION FACILITIES 1005.3 Edge Protection. Where railings, guards, or handrails complying with 1005.2 are provided, edge protection complying with 1005.3.1 or 1005.3.2 shall be provided. Advisory 1005.3 Edge Protection. Edge protection is required only where railings, guards, or handrails are provided on a fishing pier or platform. Edge protection will prevent wheelchairs or other mobility devices from slipping off the fishing pier or platform. Extending the deck of the fishing pier or platform 12 inches (305 mm) where the 34 inch (865 mm) high railing is provided is an alternative design, permitting individuals using wheelchairs or other mobility devices to pull into a clear space and move beyond the face of the railing. In such a design, curbs or barriers are not required. 1005.3.1 Curb or Barrier. Curbs or barriers shall extend 2 inches (51 mm) minimum above the surface of the fishing pier or platform. 1005.3.2 Extended Ground or Deck Surface. The ground or deck surface shall extend 12 inches (305 mm) minimum beyond the inside face of the railing. Toe clearance shall be provided and shall be 30 inches (760 mm) wide minimum and 9 inches (230 mm) minimum above the ground or deck surface beyond the railing. FIGURE 1005.3.2 EXTENDED GROUND OR DECK SURFACE AT FISHING PIERS AND PLATFORMS 1005.4 Clear Floor or Ground Space. At each location where there are railings, guards, or handrails complying with 1005.2.1, a clear floor or ground space complying with 305 shall be provided. Where there are no railings, guards, or handrails, at least one clear floor or ground space complying with 305 shall be provided on the fishing pier or platform. 1005.5 Turning Space. At least one turning space complying with 304.3 shall be provided on fishing piers and platforms. 1006 GOLF FACILITIES 1006.1 General. Golf facilities shall comply with 1006. 1006.2 Accessible Routes. Accessible routes serving teeing grounds, practice teeing grounds, putting greens, practice putting greens, teeing stations at driving ranges, course weather shelters, golf car rental areas, bag drop areas, and course toilet rooms shall comply with Chapter 4 and shall be 48 inches (1220 mm) wide minimum. Where handrails are provided, accessible routes shall be 60 inches (1525 mm) wide minimum. EXCEPTION: Handrails shall not be required on golf courses. Where handrails are provided on golf courses, the handrails shall not be required to comply with 505. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 167 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 10: RECREATION FACILITIES TECHNICAL Advisory 1006.2 Accessible Routes. The 48 inch (1220 mm) minimum width for the accessible route is necessary to ensure passage of a golf car on either the accessible route or the golf car passage. This is important where the accessible route is used to connect the golf car rental area, bag drop areas, practice putting greens, practice teeing grounds, course toilet rooms, and course weather shelters. These are areas outside the boundary of the golf course, but are areas where an individual using an adapted golf car may travel. A golf car passage may not be substituted for other accessible routes to be located outside the boundary of the course. For example, an accessible route connecting an accessible parking space to the entrance of a golf course clubhouse is not covered by this provision. Providing a golf car passage will permit a person that uses a golf car to practice driving a golf ball from the same position and stance used when playing the game. Additionally, the space required for a person using a golf car to enter and maneuver within the teeing stations required to be accessible should be considered. 1006.3 Golf Car Passages. Golf car passages shall comply with 1006.3. 1006.3.1 Clear Width. The clear width of golf car passages shall be 48 inches (1220 mm) minimum. 1006.3.2 Barriers. Where curbs or other constructed barriers prevent golf cars from entering a fairway, openings 60 inches (1525 mm) wide minimum shall be provided at intervals not to exceed 75 yards (69 m). 1006.4 Weather Shelters. A clear floor or ground space 60 inches (1525 mm) minimum by 96 inches (2440 mm) minimum shall be provided within weather shelters. 1007 MINIATURE GOLF FACILITIES 1007.1 General. Miniature golf facilities shall comply with 1007. 1007.2 Accessible Routes. Accessible routes serving holes on miniature golf courses shall comply with Chapter 4. Accessible routes located on playing surfaces of miniature golf holes shall be permitted to use the exceptions in 1007.2. EXCEPTIONS: 1. Playing surfaces shall not be required to comply with 302.2. 2. Where accessible routes intersect playing surfaces of holes, a 1 inch (25 mm) maximum curb shall be permitted for a width of 32 inches (815 mm) minimum. 3. A slope not steeper than 1:4 for a 4 inch (100 mm) maximum rise shall be permitted. 4. Ramp landing slopes specified by 405.7.1 shall be permitted to be 1:20 maximum. 5. Ramp landing length specified by 405.7.3 shall be permitted to be 48 inches (1220 mm) long minimum. 6. Ramp landing size specified by 405.7.4 shall be permitted to be 48 inches (1220 mm) minimum by 60 inches (1525 mm) minimum. 7. Handrails shall not be required on holes. Where handrails are provided on holes, the handrails shall not be required to comply with 505. 1007.3 Miniature Golf Holes. Miniature golf holes shall comply with 1007.3. 1007.3.1 Start of Play. A clear floor or ground space 48 inches (1220 mm) minimum by 60 inches (1525 mm) minimum with slopes not steeper than 1:48 shall be provided at the start of play. 1007.3.2 Golf Club Reach Range Area. All areas within holes where golf balls rest shall be within 36 inches (915 mm) maximum of a clear floor or ground space 36 inches (915 mm) wide minimum and 48 inches (1220 mm) long minimum having a running slope not steeper than 1:20. The clear floor or ground space shall be served by an accessible route. Advisory 1007.3.2 Golf Club Reach Range Area. The golf club reach range applies to all holes required to be accessible. This includes accessible routes provided adjacent to or, where provided, on the playing surface of the hole. 168 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 TECHNICAL CHAPTER 10: RECREATION FACILITIES FIGURE 1007.3.2 GOLF CLUB REACH RANGE AREA 1008 PLAY AREAS 1008.1 General. Play areas shall comply with 1008. 1008.2 Accessible Routes. Accessible routes serving play areas shall comply with Chapter 4 and 1008.2 and shall be permitted to use the exceptions in 1008.2.1 through 1008.2.3. Where accessible routes serve ground level play components, the vertical clearance shall be 80 inches high (2030 mm) minimum. 1008.2.1 Ground Level and Elevated Play Components. Accessible routes serving ground level play components and elevated play components shall be permitted to use the exceptions in 1008.2.1. EXCEPTIONS: 1. Transfer systems complying with 1008.3 shall be permitted to connect elevated play components except where 20 or more elevated play components are provided no more than 25 percent of the elevated play components shall be permitted to be connected by transfer systems. 2. Where transfer systems are provided, an elevated play component shall be permitted to connect to another elevated play component as part of an accessible route. 1008.2.2 Soft Contained Play Structures. Accessible routes serving soft contained play structures shall be permitted to use the exception in 1008.2.2. EXCEPTION: Transfer systems complying with 1008.3 shall be permitted to be used as part of an accessible route. 1008.2.3 Water Play Components. Accessible routes serving water play components shall be permitted to use the exceptions in 1008.2.3. EXCEPTIONS: 1. Where the surface of the accessible route, clear floor or ground spaces, or turning spaces serving water play components is submerged, compliance with 302, 403.3, 405.2, 405.3, and 1008.2.6 shall not be required. 2. Transfer systems complying with 1008.3 shall be permitted to connect elevated play components in water. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 169 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 10: RECREATION FACILITIES TECHNICAL Advisory 1008.2.3 Water Play Components. Personal wheelchairs and mobility devices may not be appropriate for submerging in water when using play components in water. Some may have batteries, motors, and electrical systems that when submerged in water may cause damage to the personal mobility device or wheelchair or may contaminate the water. Providing an aquatic wheelchair made of non-corrosive materials and designed for access into the water will protect the water from contamination and avoid damage to personal wheelchairs. 1008.2.4 Clear Width. Accessible routes connecting play components shall provide a clear width complying with 1008.2.4. 1008.2.4.1 Ground Level. At ground level, the clear width of accessible routes shall be 60 inches (1525 mm) minimum. EXCEPTIONS: 1. In play areas less than 1000 square feet (93 m2), the clear width of accessible routes shall be permitted to be 44 inches (1120 mm) minimum, if at least one turning space complying with 304.3 is provided where the restricted accessible route exceeds 30 feet (9145 mm) in length. 2. The clear width of accessible routes shall be permitted to be 36 inches (915 mm) minimum for a distance of 60 inches (1525 mm) maximum provided that multiple reduced width segments are separated by segments that are 60 inches (1525 mm) wide minimum and 60 inches (1525 mm) long minimum. 1008.2.4.2 Elevated. The clear width of accessible routes connecting elevated play components shall be 36 inches (915 mm) minimum. EXCEPTIONS: 1. The clear width of accessible routes connecting elevated play components shall be permitted to be reduced to 32 inches (815 mm) minimum for a distance of 24 inches (610 mm) maximum provided that reduced width segments are separated by segments that are 48 inches (1220 mm) long minimum and 36 inches (915 mm) wide minimum. 2. The clear width of transfer systems connecting elevated play components shall be permitted to be 24 inches (610 mm) minimum. 1008.2.5 Ramps. Within play areas, ramps connecting ground level play components and ramps connecting elevated play components shall comply with 1008.2.5. 1008.2.5.1 Ground Level. Ramp runs connecting ground level play components shall have a running slope not steeper than 1:16. 1008.2.5.2 Elevated. The rise for any ramp run connecting elevated play components shall be 12 inches (305 mm) maximum. 1008.2.5.3 Handrails. Where required on ramps serving play components, the handrails shall comply with 505 except as modified by 1008.2.5.3. EXCEPTIONS: 1. Handrails shall not be required on ramps located within ground level use zones. 2. Handrail extensions shall not be required. 1008.2.5.3.1 Handrail Gripping Surfaces. Handrail gripping surfaces with a circular cross section shall have an outside diameter of 0.95 inch (24 mm) minimum and 1.55 inches (39 mm) maximum. Where the shape of the gripping surface is non-circular, the handrail shall provide an equivalent gripping surface. 1008.2.5.3.2 Handrail Height. The top of handrail gripping surfaces shall be 20 inches (510 mm) minimum and 28 inches (710 mm) maximum above the ramp surface. 1008.2.6 Ground Surfaces. Ground surfaces on accessible routes, clear floor or ground spaces, and turning spaces shall comply with 1008.2.6. 170 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 TECHNICAL CHAPTER 10: RECREATION FACILITIES Advisory 1008.2.6 Ground Surfaces. Ground surfaces must be inspected and maintained regularly to ensure continued compliance with the ASTM F 1951 standard. The type of surface material selected and play area use levels will determine the frequency of inspection and maintenance activities. 1008.2.6.1 Accessibility. Ground surfaces shall comply with ASTM F 1951 (incorporated by reference, see “Referenced Standards” in Chapter 1). Ground surfaces shall be inspected and maintained regularly and frequently to ensure continued compliance with ASTM F 1951. 1008.2.6.2 Use Zones. Ground surfaces located within use zones shall comply with ASTM F 1292 (1999 edition or 2004 edition) (incorporated by reference, see “Referenced Standards” in Chapter 1). 1008.3 Transfer Systems. Where transfer systems are provided to connect to elevated play components, transfer systems shall comply with 1008.3. Advisory 1008.3 Transfer Systems. Where transfer systems are provided, consideration should be given to the distance between the transfer system and the elevated play components. Moving between a transfer platform and a series of transfer steps requires extensive exertion for some children. Designers should minimize the distance between the points where a child transfers from a wheelchair or mobility device and where the elevated play components are located. Where elevated play components are used to connect to another elevated play component instead of an accessible route, careful consideration should be used in the selection of the play components used for this purpose. 1008.3.1 Transfer Platforms. Transfer platforms shall be provided where transfer is intended from wheelchairs or other mobility aids. Transfer platforms shall comply with 1008.3.1. FIGURE 1008.3.1 TRANSFER PLATFORMS 1008.3.1.1 Size. Transfer platforms shall have level surfaces 14 inches (355 mm) deep minimum and 24 inches (610 mm) wide minimum. 1008.3.1.2 Height. The height of transfer platforms shall be 11 inches (280 mm) minimum and 18 inches (455 mm) maximum measured to the top of the surface from the ground or floor surface. 1008.3.1.3 Transfer Space. A transfer space complying with 305.2 and 305.3 shall be provided adjacent to the transfer platform. The 48 inch (1220 mm) long minimum dimension of the transfer space shall be centered on and parallel to the 24 inch (610 mm) long minimum side of the transfer platform. The side of the transfer platform serving the transfer space shall be unobstructed. 1008.3.1.4 Transfer Supports. At least one means of support for transferring shall be provided. 1008.3.2 Transfer Steps. Transfer steps shall be provided where movement is intended from transfer platforms to levels with elevated play components required to be on accessible routes. Transfer steps shall comply with 1008.3.2. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 171 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 10: RECREATION FACILITIES TECHNICAL FIGURE 1008.3.2 TRANSFER STEPS 1008.3.2.1 Size. Transfer steps shall have level surfaces 14 inches (355 mm) deep minimum and 24 inches (610 mm) wide minimum. 1008.3.2.2 Height. Each transfer step shall be 8 inches (205 mm) high maximum. 1008.3.2.3 Transfer Supports. At least one means of support for transferring shall be provided. Advisory 1008.3.2.3 Transfer Supports. Transfer supports are required on transfer platforms and transfer steps to assist children when transferring. Some examples of supports include a rope loop, a loop type handle, a slot in the edge of a flat horizontal or vertical member, poles or bars, or D rings on the corner posts. 1008.4 Play Components. Ground level play components on accessible routes and elevated play components connected by ramps shall comply with 1008.4. 1008.4.1 Turning Space. At least one turning space complying with 304 shall be provided on the same level as play components. Where swings are provided, the turning space shall be located immediately adjacent to the swing. 1008.4.2 Clear Floor or Ground Space. Clear floor or ground complying with 305.2 and 305.3 shall be provided at play components. Advisory 1008.4.2 Clear Floor or Ground Space. Clear floor or ground spaces, turning spaces, and accessible routes are permitted to overlap within play areas. A specific location has not been designated for the clear floor or ground spaces or turning spaces, except swings, because each play component may require that the spaces be placed in a unique location. Where play components include a seat or entry point, designs that provide for an unobstructed transfer from a wheelchair or other mobility device are recommended. This will enhance the ability of children with disabilities to independently use the play component. When designing play components with manipulative or interactive features, consider appropriate reach ranges for children seated in wheelchairs. The following table provides guidance on reach ranges for children seated in wheelchairs. These dimensions apply to either forward or side reaches. The reach ranges are appropriate for use with those play components that children seated in wheelchairs may access and reach. Where transfer systems provide access to elevated play components, the reach ranges are not appropriate. FORWARD OR SIDE REACH High (maximum) Low (minimum) 172 CHILDREN’S REACH RANGES AGES 3 AND 4 AGES 5 THROUGH 8 36 in (915) 20 in (510 mm) 40 in (1015 mm) 18 in (455 mm) AGES 9 THROUGH 12 44 in (1120 mm) 16 in (405 mm) FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 TECHNICAL CHAPTER 10: RECREATION FACILITIES 1008.4.3 Play Tables. Where play tables are provided, knee clearance 24 inches (610 mm) high minimum, 17 inches deep (430 mm) minimum, and 30 inches (760 mm) wide minimum shall be provided. The tops of rims, curbs, or other obstructions shall be 31 inches (785 mm) high maximum. EXCEPTION: Play tables designed and constructed primarily for children 5 years and younger shall not be required to provide knee clearance where the clear floor or ground space required by 1008.4.2 is arranged for a parallel approach. 1008.4.4 Entry Points and Seats. Where play components require transfer to entry points or seats, the entry points or seats shall be 11 inches (280 mm) minimum and 24 inches (610 mm) maximum from the clear floor or ground space. EXCEPTION: Entry points of slides shall not be required to comply with 1008.4.4. 1008.4.5 Transfer Supports. Where play components require transfer to entry points or seats, at least one means of support for transferring shall be provided. 1009 SWIMMING POOLS, WADING POOLS, AND SPAS 1009.1 General. Where provided, pool lifts, sloped entries, transfer walls, transfer systems, and pool stairs shall comply with 1009. 1009.2 Pool Lifts. Pool lifts shall comply with 1009.2. Advisory 1009.2 Pool Lifts. There are a variety of seats available on pool lifts ranging from sling seats to those that are preformed or molded. Pool lift seats with backs will enable a larger population of persons with disabilities to use the lift. Pool lift seats that consist of materials that resist corrosion and provide a firm base to transfer will be usable by a wider range of people with disabilities. Additional options such as armrests, head rests, seat belts, and leg support will enhance accessibility and better accommodate people with a wide range of disabilities. 1009.2.1 Pool Lift Location. Pool lifts shall be located where the water level does not exceed 48 inches (1220 mm). EXCEPTIONS: 1. Where the entire pool depth is greater than 48 inches (1220 mm), compliance with 1009.2.1 shall not be required. 2. Where multiple pool lift locations are provided, no more than one pool lift shall be required to be located in an area where the water level is 48 inches (1220 mm) maximum. 1009.2.2 Seat Location. In the raised position, the centerline of the seat shall be located over the deck and 16 inches (405 mm) minimum from the edge of the pool. The deck surface between the centerline of the seat and the pool edge shall have a slope not steeper than 1:48. FIGURE 1009.2.2 POOL LIFT SEAT LOCATION 1009.2.3 Clear Deck Space. On the side of the seat opposite the water, a clear deck space shall be provided parallel with the seat. The space shall be 36 inches (915 mm) wide minimum and shall extend forward 48 inches (1220 mm) minimum from a line located 12 inches (305 mm) behind the rear edge of the seat. The clear deck space shall have a slope not steeper than 1:48. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 173 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 10: RECREATION FACILITIES TECHNICAL FIGURE 1009.2.3 CLEAR DECK SPACE AT POOL LIFTS 1009.2.4 Seat Height. The height of the lift seat shall be designed to allow a stop at 16 inches (405 mm) minimum to 19 inches (485 mm) maximum measured from the deck to the top of the seat surface when in the raised (load) position. FIGURE 1009.2.4 POOL LIFT SEAT HEIGHT 1009.2.5 Seat Width. The seat shall be 16 inches (405 mm) wide minimum. 1009.2.6 Footrests and Armrests. Footrests shall be provided and shall move with the seat. If provided, the armrest positioned opposite the water shall be removable or shall fold clear of the seat when the seat is in the raised (load) position. EXCEPTION: Footrests shall not be required on pool lifts provided in spas. 1009.2.7 Operation. The lift shall be capable of unassisted operation from both the deck and water levels. Controls and operating mechanisms shall be unobstructed when the lift is in use and shall comply with 309.4. Advisory 1009.2.7 Operation. Pool lifts must be capable of unassisted operation from both the deck and water levels. This will permit a person to call the pool lift when the pool lift is in the opposite position. It is extremely important for a person who is swimming alone to be able to call the pool lift when it is in the up position so he or she will not be stranded in the water for extended periods of time awaiting assistance. The requirement for a pool lift to be independently operable does not preclude assistance from being provided. 1009.2.8 Submerged Depth. The lift shall be designed so that the seat will submerge to a water depth of 18 inches (455 mm) minimum below the stationary water level. 174 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 TECHNICAL CHAPTER 10: RECREATION FACILITIES FIGURE 1009.2.8 POOL LIFT SUBMERGED DEPTH 1009.2.9 Lifting Capacity. Single person pool lifts shall have a weight capacity of 300 pounds (136 kg) minimum and be capable of sustaining a static load of at least one and a half times the rated load. Advisory 1009.2.9 Lifting Capacity. Single person pool lifts must be capable of supporting a minimum weight of 300 pounds (136 kg) and sustaining a static load of at least one and a half times the rated load. Pool lifts should be provided that meet the needs of the population they serve. Providing a pool lift with a weight capacity greater than 300 pounds (136 kg) may be advisable. 1009.3 Sloped Entries. Sloped entries shall comply with 1009.3. Advisory 1009.3 Sloped Entries. Personal wheelchairs and mobility devices may not be appropriate for submerging in water. Some may have batteries, motors, and electrical systems that when submerged in water may cause damage to the personal mobility device or wheelchair or may contaminate the pool water. Providing an aquatic wheelchair made of non-corrosive materials and designed for access into the water will protect the water from contamination and avoid damage to personal wheelchairs or other mobility aids. 1009.3.1 Sloped Entries. Sloped entries shall comply with Chapter 4 except as modified in 1109.3.1 through 1109.3.3. EXCEPTION: Where sloped entries are provided, the surfaces shall not be required to be slip resistant. 1009.3.2 Submerged Depth. Sloped entries shall extend to a depth of 24 inches (610 mm) minimum and 30 inches (760 mm) maximum below the stationary water level. Where landings are required by 405.7, at least one landing shall be located 24 inches (610 mm) minimum and 30 inches (760 mm) maximum below the stationary water level. EXCEPTION: In wading pools, the sloped entry and landings, if provided, shall extend to the deepest part of the wading pool. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 175 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 10: RECREATION FACILITIES TECHNICAL FIGURE 1009.3.2 SLOPED ENTRY SUBMERGED DEPTH 1009.3.3 Handrails. At least two handrails complying with 505 shall be provided on the sloped entry. The clear width between required handrails shall be 33 inches (840 mm) minimum and 38 inches (965 mm) maximum. EXCEPTIONS: 1. Handrail extensions specified by 505.10.1 shall not be required at the bottom landing serving a sloped entry. 2. Where a sloped entry is provided for wave action pools, leisure rivers, sand bottom pools, and other pools where user access is limited to one area, the handrails shall not be required to comply with the clear width requirements of 1009.3.3. 3. Sloped entries in wading pools shall not be required to provide handrails complying with 1009.3.3. If provided, handrails on sloped entries in wading pools shall not be required to comply with 505. FIGURE 1009.3.3 HANDRAILS FOR SLOPED ENTRY 1009.4 Transfer Walls. Transfer walls shall comply with 1009.4. 1009.4.1 Clear Deck Space. A clear deck space of 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer wall. Where one grab bar is provided, the clear deck space shall be centered on the grab bar. Where two grab bars are provided, the clear deck space shall be centered on the clearance between the grab bars. 176 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 TECHNICAL CHAPTER 10: RECREATION FACILITIES FIGURE 1009.4.1 CLEAR DECK SPACE AT TRANSFER WALLS 1009.4.2 Height. The height of the transfer wall shall be 16 inches (405 mm) minimum and 19 inches (485 mm) maximum measured from the deck. FIGURE 1009.4.2 TRANSFER WALL HEIGHT 1009.4.3 Wall Depth and Length. The depth of the transfer wall shall be 12 inches (305 mm) minimum and 16 inches (405 mm) maximum. The length of the transfer wall shall be 60 inches (1525 mm) minimum and shall be centered on the clear deck space. FIGURE 1009.4.3 DEPTH AND LENGTH OF TRANSFER WALLS FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 177 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 10: RECREATION FACILITIES TECHNICAL 1009.4.4 Surface. Surfaces of transfer walls shall not be sharp and shall have rounded edges. 1009.4.5 Grab Bars. At least one grab bar complying with 609 shall be provided on the transfer wall. Grab bars shall be perpendicular to the pool wall and shall extend the full depth of the transfer wall. The top of the gripping surface shall be 4 inches (100 mm) minimum and 6 inches (150 mm) maximum above transfer walls. Where one grab bar is provided, clearance shall be 24 inches (610 mm) minimum on both sides of the grab bar. Where two grab bars are provided, clearance between grab bars shall be 24 inches (610 mm) minimum. EXCEPTION: Grab bars on transfer walls shall not be required to comply with 609.4. FIGURE 1009.4.5 GRAB BARS FOR TRANSFER WALLS 1009.5 Transfer Systems. Transfer systems shall comply with 1009.5. 1009.5.1 Transfer Platform. A transfer platform shall be provided at the head of each transfer system. Transfer platforms shall provide 19 inches (485 mm) minimum clear depth and 24 inches (610 mm) minimum clear width. FIGURE 1009.5.1 SIZE OF TRANSFER PLATFORM 1009.5.2 Transfer Space. A transfer space of 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall be centered along a 24 inch (610 mm) minimum side of the transfer platform. The side of the transfer platform serving the transfer space shall be unobstructed. 178 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 TECHNICAL CHAPTER 10: RECREATION FACILITIES FIGURE 1009.5.2 CLEAR DECK SPACE AT TRANSFER PLATFORM 1009.5.3 Height. The height of the transfer platform shall comply with 1009.4.2. 1009.5.4 Transfer Steps. Transfer step height shall be 8 inches (205 mm) maximum. The surface of the bottom tread shall extend to a water depth of 18 inches (455 mm) minimum below the stationary water level. Advisory 1009.5.4 Transfer Steps. Where possible, the height of the transfer step should be minimized to decrease the distance an individual is required to lift up or move down to reach the next step to gain access. FIGURE 1009.5.4 TRANSFER STEPS 1009.5.5 Surface. The surface of the transfer system shall not be sharp and shall have rounded edges. 1009.5.6 Size. Each transfer step shall have a tread clear depth of 14 inches (355 mm) minimum and 17 inches (430 mm) maximum and shall have a tread clear width of 24 inches (610 mm) minimum. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 179 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 10: RECREATION FACILITIES TECHNICAL FIGURE 1009.5.6 SIZE OF TRANSFER STEPS 1009.5.7 Grab Bars. At least one grab bar on each transfer step and the transfer platform or a continuous grab bar serving each transfer step and the transfer platform shall be provided. Where a grab bar is provided on each step, the tops of gripping surfaces shall be 4 inches (100 mm) minimum and 6 inches (150 mm) maximum above each step and transfer platform. Where a continuous grab bar is provided, the top of the gripping surface shall be 4 inches (100 mm) minimum and 6 inches (150 mm) maximum above the step nosing and transfer platform. Grab bars shall comply with 609 and be located on at least one side of the transfer system. The grab bar located at the transfer platform shall not obstruct transfer. EXCEPTION: Grab bars on transfer systems shall not be required to comply with 609.4. FIGURE 1009.5.7 GRAB BARS 1009.6 Pool Stairs. Pool stairs shall comply with 1009.6. 1009.6.1 Pool Stairs. Pool stairs shall comply with 504. EXCEPTION: Pool step riser heights shall not be required to be 4 inches (100 mm) high minimum and 7 inches (180 mm) high maximum provided that riser heights are uniform. 1009.6.2 Handrails. The width between handrails shall be 20 inches (510 mm) minimum and 24 inches (610 mm) maximum. Handrail extensions required by 505.10.3 shall not be required on pool stairs. 1010 SHOOTING FACILITIES WITH FIRING POSITIONS 1010.1 Turning Space. A circular turning space 60 inches (1525 mm) diameter minimum with slopes not steeper than 1:48 shall be provided at shooting facilities with firing positions. 180 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 LIST OF FIGURES Figure 104 Graphic Convention for Figures .................................................................................... 3 Figure 302.2 Carpet Pile Height....................................................................................................... 61 Figure 302.3 Elongated Openings in Floor or Ground Surfaces ...................................................... 62 Figure 303.2 Vertical Change in Level ............................................................................................. 62 Figure 303.3 Beveled Change in Level ............................................................................................ 62 Figure 304.3.2 T-Shaped Turning Space............................................................................................ 63 Figure 305.3 Clear Floor or Ground Space ...................................................................................... 64 Figure 305.5 Position of Clear Floor or Ground Space .................................................................... 64 Figure 305.7.1 Maneuvering Clearance in an Alcove, Forward Approach.......................................... 64 Figure 305.7.2 Maneuvering Clearance in an Alcove, Parallel Approach ........................................... 65 Figure 306.2 Toe Clearance ............................................................................................................ 65 Figure 306.3 Knee Clearance .......................................................................................................... 66 Figure 307.2 Limits of Protruding Objects........................................................................................ 67 Figure 307.3 Post-Mounted Protruding Objects............................................................................... 67 Figure 307.4 Vertical Clearance....................................................................................................... 68 Figure 308.2.1 Unobstructed Forward Reach ..................................................................................... 68 Figure 308.2.2 Obstructed High Forward Reach ................................................................................ 69 Figure 308.3.1 Unobstructed Side Reach ........................................................................................... 69 Figure 308.3.2 Obstructed High Side Reach ...................................................................................... 70 Figure 403.5.1 Clear Width of an Accessible Route ........................................................................... 71 Figure 403.5.2 Clear Width at Turn..................................................................................................... 72 Figure 404.2.3 Clear Width of Doorways ............................................................................................ 73 Figure 404.2.4.1 Maneuvering Clearances at Manual Swinging Doors and Gates .......................... 74-75 Figure 404.2.4.2 Maneuvering Clearances at Doorways without Doors, Sliding Doors, Gates, and Folding Doors ............................................................................ 76 Figure 404.2.4.3 Maneuvering Clearances at Recessed Doors and Gates ........................................... 77 Figure 404.2.6 Doors in Series and Gates in Series........................................................................... 77 Figure 405.7 Ramp Landings........................................................................................................... 80 Figure 405.9.1 Extended Floor or Ground Surface Edge Protection .................................................. 81 Figure 405.9.2 Curb or Barrier Edge Protection.................................................................................. 81 Figure 406.2 Counter Slope of Surfaces Adjacent to Curb Ramps.................................................. 82 Figure 406.3 Sides of Curb Ramps.................................................................................................. 82 Figure 406.4 Landings at the Top of Curb Ramps ........................................................................... 82 Figure 406.6 Diagonal or Corner Type Curb Ramps ....................................................................... 83 Figure 406.7 Islands in Crossings.................................................................................................... 83 Figure 406.8 Detectable Warnings at Curb Ramps Subject to DOT Regulation 49 CFR 37.21 ............................................................................... 84 Figure 407.2.2.2 Visible Hall Signals ..................................................................................................... 85 Figure 407.2.3.1 Floor Designations on Jambs of Elevator Hoistway Entrances .................................. 86 Figure 407.2.3.2 Car Designations on Jambs of Destination-Oriented Elevator Hoistway Entrances................................................................................................. 86 Figure 407.4.1 Elevator Car Dimensions ....................................................................................... 88-89 Figure 408.4.1 Limited-Use/Limited-Application (LULA) Elevator Car Dimensions ............................ 93 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 181 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 LIST OF FIGURES Figure 409.4.6.2 Location of Private Residence Elevator Control Panel ............................................... 95 Figure 410.6 Platform Lift Doors and Gates..................................................................................... 96 Figure 502.2 Vehicle Parking Spaces .............................................................................................. 97 Figure 502.3 Parking Space Access Aisle ....................................................................................... 98 Figure 503.3 Passenger Loading Zone Access Aisle..................................................................... 100 Figure 504.5 Stair Nosings............................................................................................................. 101 Figure 505.4 Handrail Height ......................................................................................................... 102 Figure 505.5 Handrail Clearance ................................................................................................... 103 Figure 505.6 Horizontal Projections Below Gripping Surface ........................................................ 103 Figure 505.7.2 Handrail Non-Circular Cross Section ........................................................................ 104 Figure 505.10.1 Top and Bottom Handrail Extension at Ramps ......................................................... 104 Figure 505.10.2 Top Handrail Extension at Stairs............................................................................... 105 Figure 505.10.3 Bottom Handrail Extension at Stairs ......................................................................... 105 Figure 602.5 Drinking Fountain Spout Location ............................................................................. 107 Figure 604.2 Water Closet Location............................................................................................... 108 Figure 604.3.1 Size of Clearance at Water Closets .......................................................................... 109 Figure 604.3.2 (Exception) Overlap of Water Closet Clearance in Residential Dwelling Units ........................................................................................................ 109 Figure 604.5.1 Side Wall Grab Bar at Water Closets........................................................................ 110 Figure 604.5.2 Rear Wall Grab Bar at Water Closets ....................................................................... 111 Figure 604.7 Dispenser Outlet Location......................................................................................... 111 Figure 604.8.1.1 Size of Wheelchair Accessible Toilet Compartment ................................................. 112 Figure 604.8.1.2 Wheelchair Accessible Toilet Compartment Doors ................................................... 112 Figure 604.8.1.4 Wheelchair Accessible Toilet Compartment Toe Clearance ..................................... 113 Figure 604.8.1.6 Wheelchair Accessible Toilet Compartment in New Construction ............................ 113 Figure 604.8.2 Ambulatory Accessible Toilet Compartment ............................................................. 114 Figure 605.2 Height and Depth of Urinals ...................................................................................... 116 Figure 607.2 Clearance for Bathtubs ............................................................................................. 117 Figure 607.4.1 Grab Bars for Bathtubs with Permanent Seats ......................................................... 118 Figure 607.4.2 Grab Bars for Bathtubs with Removable In-Tub Seats ............................................. 118 Figure 607.5 Bathtub Control Location........................................................................................... 119 Figure 608.2.1 Transfer Type Shower Compartment Size and Clearance ....................................... 120 Figure 608.2.2 Standard Roll-In Type Shower Compartment Size and Clearance ........................... 120 Figure 608.2.3 Alternate Roll-In Type Shower Compartment Size and Clearance ........................... 121 Figure 608.3.1 Grab Bars for Transfer Type Showers ...................................................................... 121 Figure 608.3.2 Grab Bars for Standard Roll-In Type Showers.......................................................... 122 Figure 608.3.3 Grab Bars for Alternate Roll-In Type Showers .......................................................... 122 Figure 608.5.1 Transfer Type Shower Compartment Control Location............................................. 123 Figure 608.5.2 Standard Roll-In Type Shower Compartment Control Location ................................ 123 Figure 608.5.3 Alternate Roll-In Type Shower Compartment Control Location ................................ 124 Figure 609.2.2 Grab Bar Non-Circular Cross Section ....................................................................... 125 Figure 609.3 Spacing of Grab Bars................................................................................................ 125 Figure 610.2 Bathtub Seats............................................................................................................ 126 Figure 610.3 Extent of Seat............................................................................................................ 126 182 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 LIST OF FIGURES Figure 610.3.1 Rectangular Shower Seat ......................................................................................... 127 Figure 610.3.2 L-Shaped Shower Seat............................................................................................. 127 Figure 611.4 Height of Laundry Compartment Opening ................................................................ 128 Figure 703.2.5 Height of Raised Characters ..................................................................................... 129 Figure 703.3.1 Braille Measurement ................................................................................................. 130 Figure 703.3.2 Position of Braille ...................................................................................................... 131 Figure 703.4.1 Height of Tactile Characters Above Finish Floor or Ground ..................................... 131 Figure 703.4.2 Location of Tactile Signs at Doors ............................................................................ 132 Figure 703.6.1 Pictogram Field ......................................................................................................... 133 Figure 703.7.2.1 International Symbol of Accessibility......................................................................... 134 Figure 703.7.2.2 International Symbol of TTY ..................................................................................... 134 Figure 703.7.2.3 Volume Control Telephone ....................................................................................... 134 Figure 703.7.2.4 International Symbol of Access for Hearing Loss ..................................................... 134 Figure 704.2.1.1 Parallel Approach to Telephone................................................................................ 135 Figure 704.2.1.2 Forward Approach to Telephone .............................................................................. 135 Figure 705.1 Size and Spacing of Truncated Domes .................................................................... 136 Figure 707.6.2 Numeric Key Layout.................................................................................................. 139 Figure 802.1.2 Width of Wheelchair Spaces in Assembly Areas ...................................................... 141 Figure 802.1.3 Depth of Wheelchair Spaces in Assembly Areas...................................................... 142 Figure 802.2.1.1 Lines of Sight Over the Heads of Seated Spectators ............................................... 142 Figure 802.2.1.2 Lines of Sight Between the Heads of Seated Spectators ......................................... 143 Figure 802.2.2.1 Lines of Sight Over the Heads of Standing Spectators............................................. 143 Figure 802.2.2.2 Lines of Sight Between the Heads of Standing Spectators ...................................... 143 Figure 804.2.1 Pass Through Kitchens............................................................................................. 145 Figure 804.2.2 U-Shaped Kitchens ................................................................................................... 145 Figure 810.2.2 Dimensions of Bus Boarding and Alighting Areas .................................................... 150 Figure 810.3 Bus Shelters.............................................................................................................. 151 Figure 810.10 (Exception) Track Crossings ..................................................................................... 152 Figure 903.4 Bench Back Support ................................................................................................. 156 Figure 904.3.2 Check-Out Aisle Counters ........................................................................................ 156 Figure 904.4 (Exception) Alteration of Sales and Service Counters .............................................. 157 Figure 1002.4.4.3 Protrusions in Wheelchair Spaces in Amusement Rides .......................................... 160 Figure 1003.3.1 Boat Slip Clearance .................................................................................................. 163 Figure 1003.3.1 (Exception 1) Clear Pier Space Reduction at Boat Slips .......................................... 164 Figure 1003.3.1 (Exception 2) Edge Protection at Boat Slips ............................................................. 164 Figure 1003.3.2 Boarding Pier Clearance ........................................................................................... 165 Figure 1003.3.2 (Exception 1) Clear Pier Space Reduction at Boarding Piers ................................... 165 Figure 1003.3.2 (Exception 2) Edge Protection at Boarding Piers...................................................... 166 Figure 1005.3.2 Extended Ground or Deck Surface at Fishing Piers and Platforms .......................... 167 Figure 1007.3.2 Golf Club Reach Range Area ................................................................................... 169 Figure 1008.3.1 Transfer Platforms .................................................................................................... 171 Figure 1008.3.2 Transfer Steps .......................................................................................................... 172 Figure 1009.2.2 Pool Lift Seat Location .............................................................................................. 173 Figure 1009.2.3 Clear Deck Space at Pool Lifts ................................................................................. 174 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 183 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 LIST OF FIGURES Figure 1009.2.4 Pool Lift Seat Height ................................................................................................. 174 Figure 1009.2.8 Pool Lift Submerged Depth ....................................................................................... 175 Figure 1009.3.2 Sloped Entry Submerged Depth ............................................................................... 176 Figure 1009.3.3 Handrails for Sloped Entry ........................................................................................ 176 Figure 1009.4.1 Clear Deck Space at Transfer Walls ......................................................................... 177 Figure 1009.4.2 Transfer Wall Height ................................................................................................. 177 Figure 1009.4.3 Depth and Length of Transfer Walls ......................................................................... 177 Figure 1009.4.5 Grab Bars for Transfer Walls .................................................................................... 178 Figure 1009.5.1 Size of Transfer Platform .......................................................................................... 178 Figure 1009.5.2 Clear Deck Space at Transfer Platform .................................................................... 179 Figure 1009.5.4 Transfer Steps........................................................................................................... 179 Figure 1009.5.6 Size of Transfer Steps............................................................................................... 180 Figure 1009.5.7 Grab Bars.................................................................................................................. 180 184 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 FAIR HOUSING ACCESSIBILITY GUIDELINES Design Guidelines for Accessible/Adaptable Dwellings Issued by the Department of Housing and Urban Development The Fair Housing Act Design Manual is published by the Department of Housing and Urban Development to assist designers and builders in meeting the accessibility requirements of the Fair Housing Act. Copies of this publication are available from the HUD Customer Service Center at 1-800-7677468. NOTE: This is a reprint of the final Fair Housing Accessibility Guidelines published in the Federal Register on March 6, 1991, Vol. 56, No. 44, pages 9472-9515. This reprint incorporates corrections to the final guidelines, which were published in the Federal Register on June 24, 1991. FLORIDA BUILDING CODE — ACCESSIBILITY, 8th EDITION (2023) 1 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 FAIR HOUSING ACCESSIBILITY GUIDELINES Contents 2 Section 1. Section 2. 3. 4. 5. Introduction Authority Purpose Scope Organization of Guidelines Definitions Fair Housing Act Design and Construction Requirements Application of the Guidelines Guidelines Requirement 1. Accessible building entrance on an accessible route. Requirement 2. Accessible and usable public and common use areas. Requirement 3. Usable doors. Requirement 4. Accessible route into and through the covered dwelling unit Requirement 5. Light switches, electrical outlets, thermostats and other environmental controls in accessible locations. Requirement 6. Reinforced walls for grab bars. Requirement 7. Usable kitchens and bathrooms. FLORIDA BUILDING CODE — ACCESSIBILITY, 8th EDITION (2023) Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 FAIR HOUSING ACCESSIBILITY GUIDELINES FAIR HOUSING ACCESSIBILITY GUIDELINES Section 1. Introduction Authority Section 804(f)(5)(C) of the Fair Housing Amendments Act of 1988 directs the Secretary of the Department of Housing and Urban Development to provide technical assistance to States, local governments, and other persons in implementing the accessibility requirements of the Fair Housing Act. These guidelines are issued under this statutory authority. Purpose The purpose of these guidelines is to provide technical guidance on designing dwelling units as required by the Fair Housing Amendments Act of 1988 (Fair Housing Act). These guidelines are not mandatory, nor do they prescribe specific requirements which must be met, and which, if not met, would constitute unlawful discrimination under the Fair Housing Act. Builders and developers may choose to depart from these guidelines and seek alternate ways to demonstrate that they have met the requirements of the Fair Housing Act. These guidelines are intended to provide a safe harbor for compliance with the accessibility requirements of the Fair Housing Act. Scope These guidelines apply only to the design and construction requirements of 24 CFR 100.205. Compliance with these guidelines do not relieve persons participating in a Federal or Federally-assisted program or activity from other requirements, such as those required by Section 504 of the Rehabilitation Act of 1973 (29 U.S.C. 794) and the Architectural Barriers Act of 1968 (42 U.S.C. 4151-4157). Accessible design requirements for Section 504 are found at CFR Part 8. Accessible design requirements for the Architectural Barriers Act are found at 24 CFR Part 40. Organization of Guidelines lifts. Exterior accessible routes may include parking access aisles, curb ramps, walks, ramps and lifts. A route that complies with the appropriate requirements of ANSI A117.1-1986, a comparable standard, or Section FHAG-5, Requirement 1 of these guidelines is an “accessible route”. In the circumstances described in SectionFHAG-5, Requirements 1 and 2, “accessible route” may include access via a vehicular route. “Adaptable dwelling units”, when used with respect to covered multifamily dwellings, means dwelling units that include the features of adaptable design specified in 24 CFR 100.205(c)(2)-(3). “ANSIA117/1-1086” means the 1986 edition of the American National Standard for buildings and facilities providing accessibility and usability for physically handicapped people. “Assistive device” means an aid, tool, or instrument used by a person with disabilities to assist in activities of daily living. Examples of assistive devices include tongs, knob-turners, and oven-rack pusher/ pullers. “Bathroom”, means a bathroom which includes a water closet (toilet), lavatory (sink), and bathtub or shower. It does not include single-fixture facilities or those with only a water closet and lavatory. It does include a compartmented bathroom. A compartmented bathroom is one in which the fixtures are distributed among interconnected rooms. A compartmented bathroom is considered a single unit and is subject to the Act’s requirements for bathrooms. “Building” means a structure, facility or portion thereof that contains or serves one or more dwelling units. “Building entrance on an accessible route” means an accessible entrance to a building that is connected by an accessible route to public transportation stops, to parking or passenger loading zones, or to public streets or sidewalks, if available. A building entrance that complies with ANSIA117.1-1986 (see SectionFHAG-5, Requirement 1 of these guidelines) or a comparable standard complies with the requirements of this paragraph. “Clear” means unobstructed. The design guidelines are incorporated in Section 5 of this document. Each guideline cites the appropriate paragraph of HUD’s regulation at 24 CFR 100-205; quotes from the regulation to identify the required design features, and states recommended specifications for each design feature. Generally, these guidelines rely on the American National Standards Institute (ANSI) A117.1-1986, American National Standard for Buildings and Facilities-Providing Accessibility and Useability for Physically Handicapped People (ANSI Standard). Where the guidelines rely on sections of the ANSI Standard, the ANSI sections are cited. Only those sections of the ANSI Standard cited in the guidelines are recommended for compliance with 24 CFR 100.205. For those guidelines that differ from the ANSI Standard, recommended specifications are provided. The texts of cited ANSI sections are not reproduced in the guidelines. The complete text of the 1986 version of the ANSI A117.1 Standard may be purchased from the American National Standards Institute, 1430 Broadway, New York, NY 10018. Section 2. Definitions As used in these Guidelines: “Accessible”, when used with respect to the public and common use areas of a building containing covered multifamily dwellings, means that the public or common use areas of the building can be approached, entered, and used by individuals with physical handicaps. The phrase “readily accessible to and usable by” is synonymous with accessible. A public or common use area that complies with the appropriate requirements of ANSIA117.1-1986, a comparable standard or these guidelines is “accessible” within the meaning of this paragraph. “Accessible route” means a continuous unobstructed path connecting accessible elements and spaces in a building or within a site that can be negotiated by a person with a severe disability using a wheelchair, and that is also safe for and usable by people with other disabilities. Interior accessible routes may include corridors, floors, ramps, elevators and FLORIDA BUILDING CODE — ACCESSIBILITY, 8th EDITION (2023) “Common use areas” means rooms, spaces or elements inside or outside of a building that are made available for the use of residents of a building or the guests thereof. These areas include hallways, lounges, lobbies, laundry rooms, refuse rooms, mail rooms, recreational areas and passageways among and between buildings. See Section FHAG-5, Requirement 2 of these guidelines. “Controlled substance” means any drug or other substance, or immediate precursor included in the definition in Section 102 of the Controlled Substances Act (21 U.S.C. 802). “Covered multifamily dwellings” or “covered multifamily dwellings subject to the Fair Housing Amendments” means buildings consisting of four or more dwelling units if such buildings have one or more elevators; and ground floor dwelling units in other buildings consisting of four or more dwelling units. Dwelling units within a single structure separated by firewalls do not constitute separate buildings. “Dwelling unit” means a single unit of residence for a household of one or more persons. Examples of dwelling units covered by these guidelines include: condominiums; an apartment unit within an apartment building; and other types of dwellings in which sleeping accommodations are provided but toileting or cooking facilities are shared by occupants of more than one room or portion of the dwelling. Examples of the latter include dormitory rooms and sleeping accommodations in shelters intended for occupancy as a residence for homeless persons. “Entrance” means any exterior access point to a building or portion of a building used by residents for the purpose of entering. For purposes of these guidelines, an “entrance” does not include a door to a loading dock or a door used primarily as a service entrance, even if nonhandicapped residents occasionally use that door to enter. “Finished grade” means the ground surface of the site after all construction, levelling, grading, and development has been completed. “Ground floor” means a floor of a building with a building entrance on 3 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 FAIR HOUSING ACCESSIBILITY GUIDELINES an accessible route. A building may have one or more ground floors. Where the first floor containing dwelling units in a building is above grade, all units on that floor must be served by a building entrance on an accessible route. This floor will be considered to be a ground floor. “Handicap” means, with respect to a person, a physical or mental impairment which substantially limits one or more major life activities; a record of such an impairment; or being regarded as having such an impairment. This term does not include current, illegal use of or addiction to a controlled substance. For purposes of these guidelines, an individual shall not be considered to have a handicap solely because that individual is a transvestite. As used in this definition: (a) “Physical or mental impairment” includes: (1) Any physiological disorder or condition, cosmetic disfigurement, or anatomical loss affecting one or more of the following body systems: Neurological; musculoskeletal; special sense organs; respiratory, including speech organs; cardiovascular; reproductive; digestive; genito-urinary; hemic and lymphatic; skin; and endocrine; or (2) Any mental or psychological disorder, such as mental retardation, organic brain syndrome, emotional or mental illness, and specific learning disabilities. The term “physical or mental impairment” includes, but is not limited to, such diseases and conditions as orthopedic, visual, speech and hearing impairments, cerebral palsy, autism, epilepsy, muscular dystrophy, multiple sclerosis, cancer, heart disease, diabetes, Human Immunodeficiency Virus infection, mental retardation, emotional illness, drug addiction (other than addiction caused by current, illegal use of a controlled substance) and alcoholism. These guidelines are designed to make units accessible or adaptable for people with physical handicaps. (b) “Major life activities” means functions such as caring for one’s self, performing manual tasks, walking, seeing, hearing, speaking, breathing, learning and working. (c) “Has a record of such an impairment” means has a history of, or has been misclassified as having, a mental or physical impairment that substantially limits one or more major life activities. (d) “Is regarded as having an impairment” means: (1) Has a physical or mental impairment that does not substantially limit one or more major life activities but that is treated by another person as constituting such a limitation; (2) Has a physical or mental impairment that substantially limits one or more major life activities only as a result of the attitudes of others toward such impairment; or (3) Has none of the impairments defined in paragraph (a) of this definition but is treated by another person as having such an impairment. “Loft” means an intermediate level between the floor and ceiling of any story, located within a room or rooms of a dwelling. “Multistory dwelling unit” means a dwelling unit with finished living space located on one floor and the floor or floors immediately above or below it. “Public use areas” means interior or exterior rooms or spaces of a building that are made available to the general public. Public use may be provided at a building that is privately or publicly owned. of any floor and the upper surface of the floor next above, or the roof of the unit. Within the context of dwelling units, the terms “story” and “floor” are synonymous. “Undisturbed site” means the site before any construction, levelling, grading, or development associated with the current project. “Vehicular or pedestrian arrival points” means public or resident parking areas, public transportation stops, passenger loading zones, and public streets or sidewalks. “Vehicular route” means a route intended for vehicular traffic, such as a street, driveway or parking lot. Section 3. Fair Housing Act Design and Construction Requirements The regulations issued by the Department at 24 CFR 100/205 state: Section100.205 Design and construction requirements. (a) Covered multifamily dwellings for first occupancy after March 13, 1991, shall be designed and constructed to have at least one building entrance on an accessible route unless it is impractical to do so because of the site. For purposes of this section, a covered multifamily dwelling shall be deemed to be designed and constructed for first occupancy on or before March 13, 1991, if they are occupied by that date or if the last building permit or renewal thereof for the covered multifamily dwellings is issued by a State, County or local government on or before January 13, 1990. The burden of establishing impracticality because of terrain or unusual site characteristics is on the person or persons who designed or constructed the housing facility. (b) The application of paragraph (a) of this section may be illustrated by the following examples: Example (1): A real estate developer plans to construct six covered multifamily dwelling units on a site with a hilly terrainches Because of the terrain it will be necessary to climb a long and steep stairway in order to enter the dwellings. Since there is no practical way to provide an accessible route to any of the dwellings, one need not be provided. Example (2): A real estate developer plans to construct a building consisting of 10 units of multifamily housing on a waterfront site that floods frequently. Because of this unusual characteristic of the site, the builder plans to construct the building on stilts. It is customary for housing in the geographic area where the site is located to be built on stilts. The housing may lawfully be constructed on the proposed site on stilts even though this means that there will be no practical way to provide an accessible route to the building entrance. Example (3): A real estate developer plans to construct a multifamily housing facility on a particular site. The developer would like the facility to be built on the site to contain as many units as possible. Because of the configuration and terrain of the site, it is possible to construct a building with 105 units on the site provided the site does not have an accessible route leading to the building entrance. It is also possible to construct a building on the site with an accessible route leading to the building entrance. However, such a building would have no more than 100 dwelling units. The building to be constructed on the site must have a building entrance on an accessible route because it is not impractical to provide such an entrance because of the terrain or unusual characteristics of the site. “Single-story dwelling unit” means a dwelling unit with all finished living space located on one floor. (c) All covered multifamily dwellings for first occupancy after March 13,1991, with a building entrance on an accessible route shall be designed and constructed in such a manner that— “Site” means a parcel of land bounded by a property line or a designated portion of a public right of way. M(1) The public and common use areas are readily accessible to and usable by handicapped persons; “Slope” means the relative steepness of the land between two points and is calculated as follows: The distance and elevation between the two points (e.,g., an entrance and a passenger loading zone) are determined from a topographical map. The difference in elevation is divided by the distance and that fraction is multiplied by 100 to obtain a percentage slope figure. For example, if a principal entrance is ten feet from a passenger loading zone, and the principal entrance is raised one foot higher than the passenger loading zone, then the slope is 1/10 x 100 = 10%. (2) All the doors designed to allow passage into and within all premises are sufficiently wide to allow passage by handicapped persons in wheelchairs; and “Story” means that portion of a dwelling unit between the upper surface 4 (3) All premises within covered multifamily dwelling units contain the following features of adaptable design: (i) An accessible route into and through the covered dwelling unit; (ii) Light switches, electrical outlets, thermostats, and other environmental controls in accessible locations: FLORIDA BUILDING CODE — ACCESSIBILITY, 8th EDITION (2023) Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 FAIR HOUSING ACCESSIBILITY GUIDELINES (iii) Reinforcements in bathroom walls to allow later installation of grab bars around the toilet, tub, shower, stall and shower seal, where such facilities are provided; and (iv) Usable kitchen and bathrooms such that an individual in a wheelchair can maneuver about the space. (d) The application of Paragraph (c) of this section may be illustrated by the following examples: Example (1): A developer plans to construct a 100 unit condominium apartment building with one elevator. In accordance with Paragraph (a), the building has at least one accessible route leading to an accessible entrance. All 100 units are covered multifamily dwelling units and they all must be designed and constructed so that they comply with the accessibility requirements of Paragraph (c) of this section. Example (3): A developer plans to construct 30 garden apartments in a three story building. The building will not have an elevator. The building will have one accessible entrance which will be on the first floor. Since the building does not have an elevator only the “ground floor” units are covered multifamily units. The “ground floor” is the first floor because that is the floor that has an accessible entrance. All of the dwelling units on the first floor must meet the accessibility requirements of Paragraph (c) of this section and must have access to at least one of each type of public or common use area available for residents in the building. (e) Compliance with the appropriate requirements of ANSI A117.11986 suffices to satisfy the requirements of Paragraph (c)(3) of this section. (f) Compliance with a duly enacted law of a State or unit of general local government that includes the requirements of Paragraphs (a) and (c) of this section satisfies the requirements of Paragraphs (a) and (c) of this section. (g)(1) It is the policy of HUD to encourage States and units of general local government to include, in their existing procedures for the review and approval of newly constructed covered multifamily dwellings, determinations as to whether the design and construction of such dwellings are consistent with Paragraphs (a) and (c) of this section. (2) A State or unit of general local government may review and approve newly constructed multifamily dwellings for the purpose of making determinations as to whether the requirements of Paragraphs (a) and (c) of this section are met. (h) Determinations of compliance or noncompliance by a State or a unit of general local government under Paragraph (f) or (g) of this section are not conclusive in enforcement proceedings under the Fair Housing Amendments Act. (i) This subpart does not invalidate or limit any law of a State or political subdivision of a State that requires dwellings to be designed and constructed in a manner that affords handicapped persons greater access than is required by this subpart. Section 4. Application of the Guidelines The design specifications (guidelines) presented in SectionFHAG-5 apply to new construction of “covered multifamily dwellings”, as defined in SectionFHAG-2. These guidelines are recommended for designing dwellings that comply with the requirements of the Fair Housing Amendments Act of 1988. Section 5. Guidelines Requirement 1. Accessible building entrance on an accessible route. Under Section 100.205(a), covered multifamily dwellings shall be designed and constructed to have at least one building entrance on an accessible route, unless it is impractical to do so because of terrain or unusual characteristics of the site. Guideline guideline applies both to a single building on a site and to multiple buildings on a site. (a) Separate ground floor unit entrances. When a ground floor unit of a building has a separate entrance, each such ground floor unit shall be served by an accessible route, except for any unit where the terrain or unusual characteristics of the site prohibit the provision of an accessible route to the entrance of that unit. (b) Multiple entrances. Only one entrance is required to be accessible to any one ground floor of a building, except in cases where an individual dwelling unit has a separate exterior entrance, or where the building contains clusters of dwelling units, with each cluster sharing a different exterior entrance. In these cases, more than one entrance may be required to be accessible, as determined by analysis of the site. In every case, the accessible entrance should be on an accessible route to the covered dwelling units it serves. (2) Site impracticality. Covered multifamily dwellings with elevators shall be designed and constructed to provide at least one accessible entrance on an accessible route, regardless of terrain or unusual characteristics of the site. Covered multifamily dwellings without elevators shall be designed and constructed to provide at least one accessible entrance on an accessible route unless terrain or unusual characteristics of the site are such that the following conditions are found to exist: (a) Site impracticality due to terrain. There are two alternative tests for determining site impracticality due to terrain: the individual building test provided in paragraph (i), or the site analysis test provided in paragraph (ii). These tests may be used as follows. A site with a single building having a common entrance for all units may be analyzed only as described in paragraph (i). All other sites, including a site with a single building having multiple entrances serving either individual dwelling units or clusters of dwelling units, may be analyzed using the methodology in either Paragraph (i) or Paragraph (ii). For these sites for which either test is applicable, regardless of which test is selected, at least 20% of the total ground floor units in nonelevator buildings, on any site, must comply with the guidelines. (i) Individual building test. It is impractical to provide an accessible entrance served by an accessible route when the terrain of the site is such that: (A) The slopes of the undisturbed site measured between the planned entrance and all vehicular or pedestrian arrival points within 50 feet of the planned entrance exceed 10 percent; and (B) the slopes of the planned finished grade measured between the entrance and all vehicular or pedestrian arrival points within 50 feet of the planned entrance also exceed 10 percent. If there are no vehicular or pedestrian arrival points within 50 feet of the planned entrance, the slope for the purposes of this Paragraph (i) will be measured to the closest vehicular or pedestrian arrival point. For purposes of these guidelines, vehicular or pedestrian arrival points include public or resident parking areas; public transportation stops; passenger loading zones; and public streets or sidewalks. To determine site impracticality, the slope would be measured at ground level from the point of the planned entrance on a straight line to (i) each vehicular or pedestrian arrival point that is within 50 feet of the planned entrance, or (ii) if there are no vehicular or pedestrian arrival points within that specified area, the vehicular or pedestrian arrival point closest to the planned entrance. In the case of sidewalks, the closest point to the entrance will be where a public sidewalk entering the site intersects with the sidewalk to the entrance. In the case of resident parking areas, the closest point to the planned entrance will be measured from the entry point to the parking area that is located closest to the planned entrance. (ii) Site analysis test. Alternatively, for a site having multiple buildings, or a site with a single building with multiple entrances, impracticality of providing an accessible entrance served by an accessible route can be established by the following steps: (1) Building entrance. Each building on a site shall have at least one building entrance on an accessible route unless prohibited by the terrain, as provided in Paragraphs (2)(a)(i) or (2)(a)(ii), or unusual characteristics of the site, as provided in Paragraph (2)(b). This (A) The percentage of the total buildable area of the undisturbed site with a natural grade less than 10% slope shall be calculated. The analysis of the existing slope (before grading) shall be done on a topographic survey with two foot (2’) contour intervals with slope determination made between each successive interval. The FLORIDA BUILDING CODE — ACCESSIBILITY, 8th EDITION (2023) 5 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 FAIR HOUSING ACCESSIBILITY GUIDELINES accuracy of the slope analysis shall be certified by a professional licensed engineer, landscape architect, architect or surveyor. (B) To determine the practicality of providing accessibility to planned multifamily dwellings based on the topography of the existing natural terrain, the minimum percentage of ground floor units to be made accessible should equal the percentage of the total buildable area (not including floodplains, wetlands, or other restricted use areas) of the undisturbed site that has an existing natural grade of less than 10% slope. (C) In addition to the percentage established in paragraph (B), all ground floor units in a building, or ground floor units served by a particular entrance, shall be made accessible if the entrance to the units is on an accessible route, defined as a walkway with a slope between the planned entrance and a pedestrian or vehicular arrival point that is no greater than 8.33%. Section 100.205(c)(1) provides that covered multifamily dwellings with a building entrance on an accessible route shall be designed in such a manner that the public and common use areas are readily accessible to and usable by handicapped persons. Guideline The following chart identifies the public and common use areas that should be made accessible, cites the appropriate section of the ANSI Standard, and describes the appropriate application of the specifications, including modifications to the referenced standard. (b) Site impracticality due to unusual characteristics. Unusual characteristics include sites located in a federally-designated floodplain or coastal high-hazard area and sites subject to other similar requirements of law or code that the lowest floor or the lowest structural member of the lowest floor must be raised to a specified level at or above the base flood elevation. An accessible route to a building entrance is impractical due to unusual characteristics of the site when: (i) the unusual site characteristics result in a difference in finished grade elevation exceeding 30 inches and 10 percent measured between an entrance and all vehicular or pedestrian arrival points within 50 feet of the planned entrance; or (ii) if there are no vehicular or pedestrian arrival points within 50 feet of the planned entrance, the unusual characteristics result in a difference in finished grade elevation exceeding 30 inches and 10 percent measured between an entrance and the closest vehicular or pedestrian arrival point. (3) Exceptions to site impracticality. Regardless of site considerations described in paragraphs (1) and (2), an accessible entrance on an accessible route is practical when: (a) There is an elevator connecting the parking area with the dwelling units on a ground floor. (In this case, those dwelling units on the ground floor served by an elevator, and at least one of each type of public and common use areas, would be subject to these guidelines.) However: (i) Where a building elevator is provided only as a means of creating an accessible route to dwelling units on a ground floor, the building is not considered an elevator building for purposes of these guidelines; hence, only the ground floor dwelling units would be covered. (ii) If the building elevator is provided as a means of access to dwelling units other than dwelling units on a ground floor, then the building is an elevator building which is a covered multifamily dwelling, and the elevator in that building must provide accessibility to all dwelling units in the building, regardless of the slope of the natural terrain; or (b) An elevated walkway is planned between a building entrance and a vehicular or pedestrian arrival point and the planned walkway has a slope no greater than 10 percent. (4) Accessible entrance. An entrance that complies with ANSI 4.14 meets Section 100.205(a). (5) Accessible route. An accessible route that complies with ANSI 4.3 would meet Section 100.205(a). If the slope of the finished grade between covered multifamily dwellings and a public or common use facility (including parking) exceeds 8.33%, or where other physical barriers (natural or manmade) or legal restrictions, all of which are outside the control of the owner, prevent the installation of an accessible pedestrian route, an acceptable alternative is to provide access via a vehicular route, so long as necessary site provisions such as parking spaces and curb ramps are provided at the public or common use facility. Requirement 2. Accessible and usable public and common use areas. 6 FLORIDA BUILDING CODE — ACCESSIBILITY, 8th EDITION (2023) Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 FAIR HOUSING ACCESSIBILITY GUIDELINES Accessible element or space 1. Accessible route(s)... ANSI A117.1 Section 4.3 Application Within the boundary of the side: (a) From public transportation stops, accessible parking spaces, accessible passenger loading zones, and public streets or sidewalks to accessible building entrances (subject to site considerations described in Section 5). (b) Connecting accessible buildings, facilities, elements and spaces that are on the same site. On-grade walks or paths between separate buildings with covered multifamily dwellings, while not required, should be accessible unless the slope of finish grade exceeds 8.33% at any point along the route. Handrails are not required on these accessible walks. (c) Connecting accessible buildingor facility entrances with accessible spaces and elements within the building or facility, including adaptable dwelling units. 2. Protruding objects..... 4.4 3. Ground and floor surface treatments.... Parking and passenger loading zones..... 4.5 Curb ramps Ramps Stairs Elevator Platform lift Drinking fountains and water coolers Drinking fountains and bathing facilities (including water closets, toilet rooms and stalls, urinals. Lavatories and mirrors, bathtubs, shower stalls, and sinks.) Seating, tables, or work surfaces Places of assembly Common-use spaces and facilities (including swimming pools, playgrounds, entrances, rental offices, lobbies, elevators, mailbox areas, lounges, halls and corridors, and the like.) Laundry rooms 4.7 4.8 4.9 4.10 4.11 4.15 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 4.6 4.22 4.30 (d) Where site or legal constraints prevent a route accessible to wheelchair users between covered multifamily dwellings and public or common-use facilities elsewhere on the site, an accept able alternative is the provision of access via a vehicular route so long as there is accessible parking on an accessible route to at least 2% of covered dwelling units and necessary site provisions such as parking and curb cuts are available at the public or common use facility. Accessible routes or maneuvering space including floors, walks, ramps, stairs, and curb ramps. Accessible routes, rooms, and spaces, including floors, walks, ramps, stairs, and curb ramps. If provided at the site, designated accessible parking at the dwelling unit on request of residents with handicaps on the same terms and with the full range of choices (e.g., surface parking or garage) that are provided for other residents of the project with accessible parking on a route accessible to wheelchairs for at least 2% of the covered dwelling units: accessible visitor parking sufficient to provide access to grade level entrances of covered multifamily dwellings; and accessible parking at facilities (e.g., swimming pools) that serve accessible buildings. Accessible routes crossing curbs. Accessible routes with slopes greater than 1:20. Stairs on accessible routes connecting levels not connected by an elevator. If provided. May be used in lieu of an elevator or ramp under certain conditions. Fifty percent of fountains and coolers on each floor, or at least one, if provided in the facility or at the site. Where provided in public-use and common-use facilities, at least one of each fixture provided per room. If provided in accessible spaces, at least one of each type provided. 4.31 If provided in the facility or at the site. 4.1 If provided in the facility or at the site: through (a) Where multiple recreational facilities (e.g., tennis courts) are provided 4.30 sufficient accessible facilities or each type to assure suitable opportunity for use by areas, lounges, persons with handicaps. (b) Where practical access to all or a portion of nature trails and jogging paths. 4.32.6 If provided in the facility or at the site, at least one or each type of appliances provided in each laundry area, except that laundry rooms serving covered multiple-family dwellings would not be required to have front-loading washers in order to meet the requirements of 100.205(c)(1). (Where front-loading washers are not provided, management will be expected to provide assistive devices on request if necessary to permit a resident to use a top loading washer.) FLORIDA BUILDING CODE — ACCESSIBILITY, 8th EDITION (2023) 7 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 FAIR HOUSING ACCESSIBILITY GUIDELINES Requirement 3. Usable doors. Section 100.205(c)(2) provides that covered multifamily dwellings with a building entrance on an accessible route shall be designed in such a manner that all the doors designed to allow passage by handicapped persons in wheelchairs. Guideline Section 100.205(c)(2) would apply to doors that are a part of an accessible route in the public and common use areas of multifamily dwellings and to doors into and within individual dwelling units. (1) On accessible routes in public and common use areas ,and for primary entry doors to covered units, doors that comply with ANSI 4.13 would meet this requirement. (2) Within individual dwelling units, doors intended for user passage through the unit which have a clear opening of at least 32 inches nominal width when the door is open 90 degrees, measured between the face of the door and the stop, would meet this requirement. (See Fig. 1(a), (b), and (c).) Openings more than 24 inches in depth are not considered doorways. (See Fig. 1(d).) Note: A 34-inch door, hung in the standard manner, provides an acceptable nominal 32-inch clear opening. This door can be adapted to provide a wider opening by using offset hinges, by removing lower portions of the door stop, or both. Pocket or sliding doors are acceptable doors in covered dwelling units and have the added advantage of not impinging on clear floor space in small rooms. The nominal 32-inch clear opening provided by a standard six-foot sliding patio door assembly is acceptable. FIGURE 1 CLEAR DOORWAY WIDTH AND DEPTH 8 FLORIDA BUILDING CODE — ACCESSIBILITY, 8th EDITION (2023) Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 FAIR HOUSING ACCESSIBILITY GUIDELINES Requirement 4 - Accessible route into and through the covered dwelling unit. Section 100.205(c)(3)(i) provides that covered multifamily dwellings with a building entrance on an accessible route shall be designed and constructed in such a manner that all premises within covered multifamily dwelling units contain an accessible route into and through the covered dwelling unit. Guideline Accessible routes into and through dwelling units would meet Section 100.205(c)(3)(i) if: (1) A minimum clear width of 36 inches is provided. (2) In single-story dwelling units, changes in level within the dwelling unit with heights between 1/4 inch and 1/2 inch are beveled with a slope no greater than 1:2. Except for design features, such as a loft or an area on a different level within a room (e.g., a sunken living room), changes in level greater than 12 inch are ramped or have other means of access. Where a single story dwelling unit has special design features, all portions of the single-story unit, except the loft or the sunken or raised area, are on an accessible route; and (a) In single-story dwelling units with lofts, all spaces other than the loft are on an accessible route. (b) Design features such as sunken or raised functional areas do not interrupt the accessible route through the remainder of the dwelling unit. (3) In multistory dwelling units in buildings with elevators, the story of the unit that is served by the building elevator (a) is the primary entry to the unit, (b) complies with Requirements 2 through 7 with respect to the rooms located on the entry/accessible floor; and (c) contains a bathroom or powder room which complies with Requirement 7. (Note: multistory dwelling units in non-elevator buildings are not covered dwelling units because, in such cases, there is no ground floor unit). (5) Exterior deck, patio, or balcony surfaces are no more than 1/2 inch below the floor level of the interior of the dwelling unit, unless they are constructed of impervious material such as concrete, brick or flagstone. In such case the surface is no more than 4 inches below the floor level of the interior of the dwelling unit, or lower if required by local building code. (6) At the primary entry door to dwelling units with direct exterior access, outside landing surfaces constructed of impervious materials such as concrete, brick or flagstone, are no more than 1/2 inch below the floor level of the interior of the dwelling unit. The finished surface of this area that is located immediately outside the entry may be sloped, up to 1/8 inch per foot (12 inches), for drainage. Requirement 5 - Light switches, electrical outlets, thermostats and other environmental controls in accessible locations. Section 100.205(c)(3)(ii) requires that all covered multifamily dwellings with a building entrance on an accessible route shall be designed and constructed in such a manner that all premises within covered multifamily dwelling unit contain light switches, electrical outlets, thermostats, and other environmental controls in accessible locations. Guideline Light switches, electrical outlets, thermostats and other environmental controls would meet Section 100.205(c)(3)(ii) if operable parts of the controls are located no higher than 48 inches, and no lower than 15 inches, above the floor. If the reach is over an obstruction (for example, an overhanging shelf) between 20 and 25 inches in depth, the maximum height is reduced to 44 inches for forward approach; or 46 inches for side approach, provided the obstruction (for example, a kitchen base cabinet) is no more than 24 inches in depth. Obstructions should not extend more than 25 inches from the wall beneath a control (See Figure FHAG-2.) Note: (4) Except as provided in Paragraphs (5) and (6) below, thresholds at exterior doors, including sliding door tracks, are no higher than 3/4 inch. Thresholds and changes in level at these locations are beveled with a slope no greater than 1:2. Controls or outlets that do not satisfy these specifications are acceptable provided that comparable controls or outlets (i.e., that perform the same functions) are provided within the same area and are accessible, in accordance with this guideline for Requirement 5. FLORIDA BUILDING CODE — ACCESSIBILITY, 8th EDITION (2023) 9 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 FAIR HOUSING ACCESSIBILITY GUIDELINES or FIGURE 2 REACH RANGES 10 FLORIDA BUILDING CODE — ACCESSIBILITY, 8th EDITION (2023) Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 FAIR HOUSING ACCESSIBILITY GUIDELINES Requirement 6 - Reinforced walls for grab bars. Section 100.205(c)(3)(iii)requires that covered multifamily dwellings with a building entrance on an accessible route shall be designed and constructed in such a manner that all premises within covered multifamily dwelling units contain reinforcements in bathroom walls to allow later installation of grab bars around toilet, tub, shower stall and shower seat, where such facilities are provided. Guideline Reinforced bathroom walls to allow later installation of grab bars around the toilet, tub, shower stall and shower seat, where such facilities are provided, would meet Section 100.205(c)(3)(iii) if reinforced areas are provided at least at those points where grab bars will be mounted. (For example, see Fig. 3, 4 and 5.) Where the toilet is not placed adjacent to a side wall, the bathroom would comply if provision was made for installation of floor mounted, foldaway or similar alternative grab bars. Where the power room (a room with a toilet and sink) is the only toilet facility located on an accessible level of a multistory dwelling unit, it must comply with this requirement for reinforced walls for grab bars. Note: Installation of bathtubs is not limited by the illustrative figures; a tub may have shelves or benches at either end; or a tub may be installed without surrounding walls, if there is provision for alternative mounting of grab bars. For example, a sunken tub placed away from walls could have reinforced areas for installation of floor-mounted grab bars. The same principle applies to shower stalls - e.g., glass-walled stalls could be planned to allow floor-mounted grab bars to be installed later. Reinforcement for grab bars may be provided in a variety of ways (for example, by plywood or wood blocking) so long as the necessary reinforcement is placed so as to permit later installation of appropriate grab bars. FIGURE 3 WATER CLOSETS IN ADAPTABLE BATHROOMS FLORIDA BUILDING CODE — ACCESSIBILITY, 8th EDITION (2023) 11 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 FAIR HOUSING ACCESSIBILITY GUIDELINES FIGURE 4 LOCATION OF GRAB BAR REINFORCEMENTS FOR ADAPTABLE BATHTUBS NOTE: The areas outlined in dashed lines represent locations for future installations of grab bars for typical fixture configurations. FIGURE 5 LOCATION OF GRAB BAR REINFORCEMENTS FOR ADAPTABLE SHOWERS NOTE: The areas outlined in dashed lines represent locations for future installations of grab bars. 12 FLORIDA BUILDING CODE — ACCESSIBILITY, 8th EDITION (2023) Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 FAIR HOUSING ACCESSIBILITY GUIDELINES Requirement 7 - Usable kitchens and bathrooms. Section 100.205(c)(3)(iv) requires that covered multifamily dwellings with a building entrance on an accessible route shall be designed and constructed in such a manner that all premises within covered multifamily dwelling units contain usable kitchens and bathrooms such that an individual in a wheelchair can maneuver about the space. Guideline (1) Usable kitchens. Usable kitchens would meet Section 100.205(c)(3)(iv) if: (a) A clear floor space at least 30 inches by 48 inches that allows a parallel approach by a person in a wheelchair is provided at the range or cooktop and sink and either a parallel or forward approach is provided at oven, dish washer, refrigerator/freezer or trash compactor. (See Figure FHAG-6) (b) Clearance between counters and all opposing base cabinets, countertops, appliances or walls is at least 40 inches. (c) In U-shaped kitchens with sink or range or cooktop at the base of the “U”, a 60-inch turning radius is provided to allow parallel approach, or base cabinets are removable at that location to allow knee space for a forward approach. (2) Usable bathrooms. To meet the requirements of Section 100.205(c)(3)(iv) either. All bathrooms in the dwelling unit comply with option 2, or the provisions of Paragraph (a): or At least one bathroom in the dwelling unit complies with the provisions of Paragraph (b), and all other bathrooms and powder rooms within the dwelling unit must be on an accessible route with usable entry doors in accordance with the guidelines for Requirements 3 and 4. However, in multistory dwelling units, only those bathrooms on the accessible level are subject to the requirements of Section 100.205(c)(3)(accessibility). Where a powder room is the only facility provided on the accessible level of a multistory dwelling unit, the powder room must comply with provisions of Paragraph (a) or Paragraph (b). Powder rooms that are subject to the requirements of Section 100.205(c)(3)(iv) must have reinforcements for grab bars as provided in the guideline for Requirement 6. (a) Bathrooms that have reinforced walls for grab bars (see Requirement 6) would meet Section 100.205(c)(3)(iv) if: (i) Sufficient maneuvering space is provided within the bathroom for a person using a wheelchair or other mobility aid to enter and close the door, use the fixtures, reopen the door and exit. Doors may swing into the clear floor space provided at any fixture if the maneuvering space is provided. Maneuvering spaces may include any kneespace or toespace available below bathroom fixtures. (ii) Clear floor space is provided at fixtures as shown in Figure FHAG-7(a), Figure FHAG-7(b), Figure FHAG-7(c) and Figure FHAG-7(d). Clear floor space at fixtures may overlap. (iii) If the shower stall is the only bathing facility provided in the covered dwelling unit, the shower stall measures at least 36 inches x 36 inches. Note: Cabinets under lavatories are acceptable provided the bathroom has space to allow a parallel approach by a person in a wheelchair; if parallel approach is not possible within the space, any cabinets provided would have to be removable to afford the necessary knee clearance for forward approach. (b) Bathrooms that have reinforced walls for grab bars (see Requirement 6) would meet Section 100.205(c)(3)(iv) if: (i) Where the door swings into the bathroom, there is a clear space (approximately 2’6" by 4’0") within the room to position a wheelchair or other mobility aid clear of the path of the door as it is closed and to permit use of fixtures. This clear space can include any kneespace and toespace available below bathroom fixtures. (ii) Where the door swings out, a clear space is provided within the bathroom for a person using a wheelchair or other mobility aid to position the wheelchair such that the person is allowed use of fixtures. There also shall be clear space to allow persons using wheelchairs to reopen the door to exit. (iii) When both tub and shower fixtures are provided in the bathroom, at least one is made accessible. When two or more lavatories in a bathroom are provided, at least one is made accessible. (iv) Toilets are located within bathrooms in a manner that permit a grab bar to be installed on one side of the fixture. In locations where toilets are adjacent to walls or bathtubs, the center line of the fixture is a minimum of 1¢6" from the obstacle. The other (non-grab bar) side of the toilet fixture is a minimum of 1’3" from the finished surface of adjoining walls, vanities or from the edge of a lavatory. (See Figure FHAG-7(a). (v) Vanities and lavatories are installed with the centerline of the fixture a minimum of 1¢3" horizontally from an adjoining wall or fixture. The top of the fixture rim is a maximum height of 2¢10" above the finished floor. If kneespace is provided below the vanity, the bottom of the apron is at least 2¢3" above the floor. If provided, full kneespace (for front approach) is at least 1¢5" deep. (See Figure FHAG-7(c).) (vi) Bathtubs and tub/showers located in the bathroom provide a clear access aisle adjacent to the lavatory that is at least 2’6" wide and extends for a length of 4¢0" (measured from the foot of the bathtub). (See Figure FHAG-8.) (vii) Stall showers in the bathroom may be of any size or configuration. A minimum clear floor space 2¢6" wide by 4¢0" should be available outside the stall. (See Figure FHAG-7(d).) If the shower stall is the only bathing facility provided in the covered dwelling unit, or on the accessible level of a covered multistory unit, and measures a nominal 36 x 36, the shower stall must have reinforcing to allow for installation of an optional wall hung bench seat. FIGURE 6 MINIMUM CLEAR FLOOR SPACE FOR WHEELCHAIRS FLORIDA BUILDING CODE — ACCESSIBILITY, 8th EDITION (2023) 13 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 FAIR HOUSING ACCESSIBILITY GUIDELINES FIGURE 7 CLEAR FLOOR SPACE FOR ADAPTABLE BATHROOMS 14 FLORIDA BUILDING CODE — ACCESSIBILITY, 8th EDITION (2023) Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 FAIR HOUSING ACCESSIBILITY GUIDELINES FIGURE 7 (continued) CLEAR FLOOR SPACE FOR ADAPTABLE BATHROOMS NOTE: Clear floor space beside tub may overlap with clear floor space beneath adjacent fixtures. Government Printing Office: 1992 - 312-222/4111 FLORIDA BUILDING CODE — ACCESSIBILITY, 8th EDITION (2023) 15 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 760 mm 2′ -6″ min FAIR HOUSING ACCESSIBILITY GUIDELINES 4′ -0″ 1220 FIGURE 8 ALTERNATIVE SPECIFICATION CLEAR FLOOR SPACE AT BATHTUB Appendix III to Ch.I, Subchapter A — Preamble to Final Housing Accessibility Guidelines (Published March 6, 1991). (FR Doc. 91-5228 Filed 3-5-91; 8:45 am) BILLING CODE 4210-38-M BILLING CODE 4210-24-C 16 FLORIDA BUILDING CODE — ACCESSIBILITY, 8th EDITION (2023) Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 ADVISORY The Federal “Barrier Removal” Mandate and the Florida Accessibility Code for Building Construction Section 101.2 of the Florida Accessibility Code for Building Construction addresses the effect of the Code on removal of barriers in existing buildings. Federal law and regulations mandate “Barrier Removal,” Florida law and the Florida Accessibility Code do not. The Florida Accessibility Code is invoked for “Barrier Removal” only when alterations are made to a facility to comply with the federal mandate either voluntarily or as directed by a federal enforcement action (28 C.F.R. 36 Subpart E). The effect of the Florida Accessibility Code is to apply Florida accessibility criteria to barrier removal measures employed to comply with the federal mandate. The US Department of Justice (DOJ) regulation 28 C.F.R. s. 36.304 for “Barrier Removal” implements the federal law mandate by requiring public accommodations to remove architectural barriers in existing facilities that are structural in nature, where removal is “readily achievable.” The mandate applies to all existing facilities including those not undergoing an alteration for some purpose. The DOJ regulation establishes guidance on “readily achievable” measures and requires compliance with the alterations requirements of the ADA Standards for Accessible Design (ADA Standards). It also provides exceptions to application of the ADA Standards to better match the “readily achievable” standard for “Barrier Removal.” Section 553.508, Florida Statutes, requires removal of architectural barriers conducted pursuant to the DOJ regulation to comply with the alterations requirements of the Florida Accessibility Code, “…unless compliance would render the removal not readily achievable.” The law both defers to the DOJ regulation to require “Barrier Removal” in existing facilities and maintains the federal “readily achievable” standard for alterations undertaken to comply with “Barrier Removal.” The DOJ regulation exceptions for application of the ADA Standards to barrier removal measures are incorporated in section 202.6.1 of the Florida Accessibility Code so the Code approach to “readily achievable” is consistent with the DOJ regulation. These Code exceptions apply only to alterations undertaken to remove architectural barriers pursuant to the DOJ regulation. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION 1 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 2 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION, 2012 EDITION Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 Building Confidence, Building Community Additional Code Resources from ICC Tools to help you learn, interpret and apply the I-Codes® Significant Changes to the 2021 International Codes® Practical resources that offer a comprehensive analysis of the critical changes since the previous edition Authored by code experts, these useful tools are “must-have” guides to the many important changes in the 2021 International Codes. Key changes are identified then followed by in-depth, expert discussion of how the change affects real world application. A full-color photo, table or illustration is included for each change to further clarify application. Significant Changes to the International Building Code, 2021 Edition Search #7024S21 Significant Changes to the International Residential Code, 2021 Edition Search #7101S21 Significant Changes to the International Fire Code, 2021 Edition Search #7404S21 Significant Changes to the International Energy Conservation Code, 2021 Edition Search #7808S21 Significant Changes to the International Plumbing Code/ International Mechanical Code/International Fuel Gas Code, 2021 Edition Search #7202S21 2021 Code Essentials A straightforward, focused approach to code fundamentals using non-code language A user-friendly, concise approach that facilitates understanding of the essential code provisions. These invaluable companion guides contain detailed full-color illustrations to enhance comprehension, references to corresponding code sections, and a glossary of code and construction terms that clarify their meaning in the context of the code. Building Code Essentials: Based on the 2021 IBC Search #4031S21 Residential Code Essentials: Based on the 2021 IRC Search #4131S21 Fire Code Essentials: Based on the 2021 IFC Search #4431S21 Energy Code Essentials: Based on the 2021 IECC Search #4831S21 Existing Building Code Essentials: Based on the 2021 IEBC Search #4552S21 Plumbing Code Essentials: Based on the 2021 IPC Search #4231S21 Mechanical Code Essentials: Based on the 2021 IMC Search #4031S21 Study Companions The ideal learning tool for exam prep or everyday application These comprehensive study guides provide practical learning assignments helpful for independent study or instructor-led programs in the workplace, college courses, or vocational training programs. Each book is organized into study sessions with clear learning objectives, key points for review, code text and commentary applicable to the specific topic, and hundreds of illustrations. A helpful practice quiz at the end of each session allows you to measure your progress along the way. The answer key lists the code section referenced in each question for further information. 2021 International Building Code Study Companion Search #4017S21 2021 International Residential Code Study Companion Search #4117S21 2021 International Fire Code Study Companion Search #4407S21 2021 International Plumbing Code Study Companion Search #4217S21 2021 International Mechanical Code Study Companion Search #4317S21 2021 International Fuel Gas Code Study Companion Search #4607S21 2021 International Energy Conservation Code Study Companion Search #4807S21 2021 Permit Technician Study Companion Search #4027S21 2021 Special Inspection Study Companion Search #4032S21 2021 Accessibility Study CompanionSearch #4123S21 Browse the latest code tools at shop.iccsafe.org 21-20563 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 codes.iccsafe.org Go Digital and Enhance Your Code Experience ICC’s Digital Codes is the most trusted and authentic source of model codes and standards, which conveniently provides access to the latest code text from across the United States. Unlock Exclusive Tools and Features with Premium Complete Search over 1,400 of the latest codes and standards from your desktop or mobile device. Saved Search allows users to save search criteria for later use without re-entering. Organize Notes and thoughts by adding personal notes, files or videos into relevant code sections. Copy, Paste and Print Copy, paste, PDF or print any code section. Share Access by configuring your license to share access and content simultaneously with others (code titles, section links, bookmarks and notes). Highlight and Annotate any code book content to keep you organized. Advanced Search narrows down your search results with multiple filters to identify codes sections more accurately. Bookmark and tag any section or subsection of interest. Stay Connected on the Go with our New Premium Mobile App • View content offline • Download up to 15 Codes titles • Utilize Premium tools and features AVA I L A B L E O N App Store AVA I L A B L E O N Google Play Monthly and Yearly Premium Subscriptions are available for: International Codes® | State Codes | Standards | Commentaries Start your FREE 14-Day Premium trial at codes.iccsafe.org/trial Learn how to use this powerful tool at codes.iccsafe.org 22-22109 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 Because Quality and Speed Matter ✓ Specify and ✓ Approve with Confidence When facing new or unfamiliar materials, look for an ICC-ES Evaluation Report or Listing before approving for installation. ICC-ES® Evaluation Reports are the most widely accepted and trusted technical reports for code compliance. ICC-ES Building Product Listings and PMG Listings show product compliance with applicable standard(s) referenced in the building and plumbing codes as well as other applicable codes. When you specify or approve products or materials with an ICC-ES report, building product listing or PMG listing, you avoid delays on projects and improve your bottom line. ICC-ES is a subsidiary of ICC®, the publisher of the codes used throughout the U.S. and many global markets, so you can be confident in their code expertise. www.icc-es.org | 800-423-6587 A subsidiary of A Mark of Confidence™ 23-22252 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 Get the New 2023 Florida Codes: Complete Collection Available starting July 1, 2023 The 8th Edition (2023) Florida Building Code is a fully integrated publication that updates the 7th Edition (2020) Florida Building Code using the latest changes to ICC’s widely adopted 2021 International Codes® with customized amendments adopted statewide. 23-22530 1-800-786-4452 | shop.iccsafe.org Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 FLORIDA BUILDING Eighth Edition CODE (2023) Building Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 FLORIDA BUILDING Eighth Edition CODE (2023) Building Item No. 5601L23 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 Florida Building Code, Building, 8th Edition (2023) First Printing: July 2023 ISBN: 978-1-960701-10-7 (loose-leaf edition) ISBN: 978-1-960701-11-4 (PDF download) COPYRIGHT © 2023 by INTERNATIONAL CODE COUNCIL, INC. ALL RIGHTS RESERVED. This Florida Building Code, Building, 8th Edition (2023) contains substantial copyrighted materials from the Florida Building Code, Building, 7th Edition (2020) and the 2021 International Building Code®, second printing, which are copyrighted works owned by the International Code Council, Inc. (“ICC”). Without separate written permission from the copyright owner, no part of this publication may be reproduced, distributed or transmitted in any form or by any means, including, without limitation, electronic, optical or mechanical means (by way of example, and not limitation, photocopying or recording by or in an information storage and/or retrieval system). For information on use rights and permissions, please contact: ICC Publications, 4051 Flossmoor Road, Country Club Hills, Illinois 60478; 1-888-ICC-SAFE (422-7233); https://www.iccsafe.org/about/periodicals-and-newsroom/icc-logo-license/. Trademarks: “International Code Council,” the “International Code Council” logo, “ICC,” the “ICC” logo, “International Building Code,” “IBC” and other names and trademarks appearing in this publication are registered trademarks of the International Code Council, Inc., and/or its licensors (as applicable), and may not be used without permission. PRINTED IN THE USA T029075 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 PREFACE History The State of Florida first mandated statewide building codes during the 1970s at the beginning of the modern construction boom. The first law required all municipalities and counties to adopt and enforce one of the four state-recognized model codes known as the “state minimum building codes.” During the early 1990s a series of natural disasters, together with the increasing complexity of building construction regulation in vastly changed markets, led to a comprehensive review of the state building code system. The study revealed that building code adoption and enforcement was inconsistent throughout the state and those local codes thought to be the strongest proved inadequate when tested by major hurricane events. The consequences of the building codes system failure were devastation to lives and economies and a statewide property insurance crisis. The response was a reform of the state building construction regulatory system that placed emphasis on uniformity and accountability. The 1998 Florida Legislature amended Chapter 553, Florida Statutes, Building Construction Standards, to create a single state building code that is enforced by local governments. As of March 1, 2002, the Florida Building Code, which is developed and maintained by the Florida Building Commission, supersedes all local building codes. The Florida Building Code is updated every three years and may be amended in the interim in accordance with criteria set out in Section 553.73, Florida Statutes. Scope The Florida Building Code is based on national model building codes and national consensus standards, in addition to Florida-specific provisions. The code incorporates all building constructionrelated regulations for public and private buildings in the State of Florida other than those specifically exempted by Section 553.73, Florida Statutes. It has been harmonized with the Florida Fire Prevention Code, which is developed and maintained by the Department of Financial Services, Office of the State Fire Marshal, to establish unified and consistent standards. The model codes used for the Florida Building Code, 8th Edition (2023) include: the 2021 editions of the International Building Code®; the International Plumbing Code®; the International Mechanical Code®; the International Fuel Gas Code®; the International Residential Code®; the International Existing Building Code®; the International Energy Conservation Code®; the National Electrical Code, 2020 edition; or substantive criteria from ASHRAE Standard 90.1-2019. State and local codes adopted and incorporated into the code include the Florida Building Code, Accessibility, and special hurricane protection standards for the High-Velocity Hurricane Zone. The code is composed of nine main volumes: the Florida Building Code, Building, which also includes state regulations for licensed facilities; the Florida Building Code, Plumbing; the Florida Building Code, Mechanical; the Florida Building Code, Fuel Gas; the Florida Building Code, Existing Building; the Florida Building Code, Residential; the Florida Building Code, Energy Conservation; the Florida Building Code, Accessibility and the Florida Building Code, Test Protocols for High-Velocity Hurricane Zones. Chapter 27 of the Florida Building Code, Building, adopts the National Electrical Code, NFPA 70, by reference. Under certain strictly defined conditions, local governments may amend technical requirements to be more stringent than the code. All local technical amendments to the Florida Building Code must be adopted in accordance with the requirements of Section 553.73(4), Florida Statutes, and reported to the Florida Building Commission, then posted on www.floridabuilding.org in legislative format for 30 days prior to being enforced. Local amendments to the Florida Building Code and the Florida Fire Prevention Code may be obtained from the Florida Building Commission website, or from the Florida Department of Business and Professional Regulation or the Florida Department of Financial Services, Office of the State Fire Marshal, respectively. FLORIDA BUILDING CODE — BUILDING, 8th EDITION (2023) iii Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 Adoption and Maintenance An updated edition of the Florida Building Code is adopted triennially by the Florida Building Commission. The code may also be amended between updates in order to incorporate the Florida Building Commission’s interpretations into the code, address conflicts, and update standards, among other statutorily specified reasons. Minimum requirements for permitting, plans review and inspections are established by the code, and local jurisdictions may adopt additional administrative requirements that are more stringent. Local technical amendments are subject to strict criteria established by Section 553.73(4), Florida Statutes. They are subject to Commission review during each triennial update of the code, and may be either adopted into the updated edition of the code or repealed. Local technical amendments are also subject to appeal according to the procedures established by Section 553.73(4), Florida Statutes. Eleven Technical Advisory Committees (TACs), which are constituted consistent with American National Standards Institute (ANSI) Guidelines, review proposed code changes and clarifications of the code and make recommendations to the Commission. These TACs whose membership is constituted consistent with American National Standards Institute (ANSI) Guidelines include: Accessibility; Joint Building Fire (a joint committee of the Commission and the State Fire Marshal); Building Structural; Code Administration/Enforcement; Electrical; Energy; Mechanical; Plumbing and Fuel Gas; Roofing; Swimming Pool; and Special Occupancy (state agency construction and facility licensing regulations). The Commission may only issue official code interpretations using procedures set out by Chapter 120, Florida Statutes. To obtain such an interpretation, a request for a declaratory statement must be made to the Florida Building Commission in a manner that establishes a clear set of facts and circumstances and identifies the section of the code in question. Requests are analyzed by staff, reviewed by the appropriate Technical Advisory Committee, and sent to the Florida Building Commission for action. These interpretations establish precedents for situations having similar facts and circumstances and are typically incorporated into the code in the next code amendment cycle. Nonbinding interpretations are available from the Building Officials Association of Florida’s website (www.BOAF.net) and a binding interpretation process is available online at www.floridabuilding.org. Marginal Markings Solid vertical lines in the margins within the body of the code indicate a change from the requirements of the Florida Building Code, Building, 7th Edition (2020) to the Florida Building Code, Building, 8th Edition (2023) effective December 31, 2023. Sections deleted from the base code are designated “Reserved” in order to maintain the structure of the base code. Italicized Terms Selected terms set forth in Chapter 2, Definitions, are italicized where they appear in code text. Such terms are not italicized where the definition set forth in Chapter 2 does not impart the intended meaning in the use of the term. The terms selected have definitions that the user should read carefully to facilitate better understanding of the code. Acknowledgments The Florida Building Code is produced through the efforts and contributions of building designers, contractors, product manufacturers, regulators and other interested parties who participate in the Florida Building Commission’s consensus processes, Commission staff and the participants in the national model code development processes. iv FLORIDA BUILDING CODE — BUILDING, 8th EDITION (2023) Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 TABLE OF CONTENTS CHAPTER 1 SCOPE AND ADMINISTRATION. . . . 1 309 Mercantile Group M. . . . . . . . . . . . . . . . . . . . . . . 63 310 Residential Group R. . . . . . . . . . . . . . . . . . . . . . . 64 PART 1—SCOPE AND APPLICATION. . . . . . . . . . . . . 1 311 Storage Group S . . . . . . . . . . . . . . . . . . . . . . . . . . 64 Section 312 Utility and Miscellaneous Group U . . . . . . . . . . . 65 101 Scope and General Requirements. . . . . . . . . . . . . . 1 102 Applicability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 CHAPTER 4 SPECIAL DETAILED REQUIREMENTS BASED ON OCCUPANCY AND USE . . . . . . . . . . 67 PART 2—ADMINISTRATION AND ENFORCEMENT . . . . . . . . . . . . . . . . . . . . . . . 4 Section 103 Department of Building Safety (Reserved) . . . . . . 4 401 Scope . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 104 Duties and Powers of Building Official . . . . . . . . . 4 402 Covered Mall and Open Mall Buildings . . . . . . . 67 105 Permits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 403 High-Rise Buildings. . . . . . . . . . . . . . . . . . . . . . . 71 106 Floor and Roof Design Loads. . . . . . . . . . . . . . . . 12 404 Atriums. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74 107 Submittal Documents . . . . . . . . . . . . . . . . . . . . . . 12 405 Underground Buildings . . . . . . . . . . . . . . . . . . . . 75 108 Temporary Structures and Uses . . . . . . . . . . . . . . 16 406 Motor-Vehicle-Related Occupancies. . . . . . . . . . 76 109 Fees. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 407 Group I-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81 110 Inspections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 408 Group I-3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84 111 Certificate of Occupancy . . . . . . . . . . . . . . . . . . . 21 409 Motion Picture Projection Rooms . . . . . . . . . . . . 86 112 Service Utilities . . . . . . . . . . . . . . . . . . . . . . . . . . 22 410 113 Board of Appeals (Reserved) . . . . . . . . . . . . . . . . 22 Stages, Platforms and Technical Production Areas . . . . . . . . . . . . . . . . . . . . . . . 87 114 Violations (Reserved). . . . . . . . . . . . . . . . . . . . . . 22 411 Special Amusement Buildings . . . . . . . . . . . . . . . 89 115 Stop Work Order . . . . . . . . . . . . . . . . . . . . . . . . . 22 412 Aircraft-Related Occupancies . . . . . . . . . . . . . . . 89 116 Unsafe Structures and Equipment (Reserved) . . . 22 413 Combustible Storage . . . . . . . . . . . . . . . . . . . . . . 93 117 Variances in Flood Hazard Areas. . . . . . . . . . . . . 22 414 Hazardous Materials . . . . . . . . . . . . . . . . . . . . . . 93 415 Groups H-1, H-2, H-3, H-4 and H-5 . . . . . . . . . . 96 416 Application of Flammable Finishes . . . . . . . . . . 106 CHAPTER 2 DEFINITIONS. . . . . . . . . . . . . . . . . . . . 23 Section 417 Drying Rooms . . . . . . . . . . . . . . . . . . . . . . . . . . 107 201 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 418 Organic Coatings . . . . . . . . . . . . . . . . . . . . . . . . 107 202 Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 419 Artificial Decorative Vegetation . . . . . . . . . . . . 107 420 Groups I-1, R-1, R-2, R-3 and R-4 . . . . . . . . . . 107 421 Hydrogen Fuel Gas Rooms . . . . . . . . . . . . . . . . 108 422 Ambulatory Care Facilities . . . . . . . . . . . . . . . . 109 CHAPTER 3 USE AND OCCUPANCY CLASSIFICATION. . . . . . . . . . . . . . . . 55 Section 423 Storm Shelters . . . . . . . . . . . . . . . . . . . . . . . . . . 109 301 Scope . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 424 Play Structures . . . . . . . . . . . . . . . . . . . . . . . . . . 110 302 Occupancy Classification and Use Designation . . . . . . . . . . . . . . . . . . . . . . . . 55 425 Hyperbaric Facilities . . . . . . . . . . . . . . . . . . . . . 110 303 Assembly Group A . . . . . . . . . . . . . . . . . . . . . . . . 55 426 Combustible Dusts, Grain Processing and Storage . . . . . . . . . . . . 110 304 Business Group B . . . . . . . . . . . . . . . . . . . . . . . . . 56 305 Educational Group E . . . . . . . . . . . . . . . . . . . . . . 56 427 through 448 Reserved. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111 306 Factory Group F . . . . . . . . . . . . . . . . . . . . . . . . . . 57 449 Hospitals. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111 307 High-Hazard Group H . . . . . . . . . . . . . . . . . . . . . 57 450 Nursing Homes . . . . . . . . . . . . . . . . . . . . . . . . . 118 308 Institutional Group I . . . . . . . . . . . . . . . . . . . . . . . 62 451 Ambulatory Surgical Centers. . . . . . . . . . . . . . . 127 FLORIDA BUILDING CODE — BUILDING, 8th EDITION (2023) v Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 TABLE OF CONTENTS 452 Birthing Centers . . . . . . . . . . . . . . . . . . . . . . . . . 131 CHAPTER 7 453 State Requirements for Educational Facilities . . . . . . . . . . . . . . . . . . . 132 Section FIRE AND SMOKE PROTECTION FEATURES . . . . . . . 241 454 Swimming Pools and Bathing Places (Public and Private). . . . . . . . . . . . . . . 150 701 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 241 702 Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 241 455 Public Lodging Establishments . . . . . . . . . . . . . 184 703 Fire-Resistance Ratings and Fire Tests . . . . . . . 241 456 Public Food Service Establishments . . . . . . . . . 185 704 457 Mental Health Programs. . . . . . . . . . . . . . . . . . . 186 Fire-Resistance Rating of Structural Members . . . . . . . . . . . . . . . . . . . . 242 458 Manufactured Buildings . . . . . . . . . . . . . . . . . . . 195 705 Exterior Walls . . . . . . . . . . . . . . . . . . . . . . . . . . 244 459 Boot Camps for Children . . . . . . . . . . . . . . . . . . 196 706 Fire Walls. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 248 460 Mausoleums and Columbariums . . . . . . . . . . . . 197 707 Fire Barriers . . . . . . . . . . . . . . . . . . . . . . . . . . . . 251 461 Transient Public Lodging Establishments . . . . . 198 708 Fire Partitions. . . . . . . . . . . . . . . . . . . . . . . . . . . 253 462 Use of Asbestos in New Public Buildings or Buildings Newly Constructed for Lease to Government Entities—Prohibition. . . . . . . . . 199 709 Smoke Barriers. . . . . . . . . . . . . . . . . . . . . . . . . . 254 710 Smoke Partitions . . . . . . . . . . . . . . . . . . . . . . . . 254 711 Floor and Roof Assemblies . . . . . . . . . . . . . . . . 255 463 Adult Day Care. . . . . . . . . . . . . . . . . . . . . . . . . . 199 712 Vertical Openings . . . . . . . . . . . . . . . . . . . . . . . 256 464 Assisted Living Facilities . . . . . . . . . . . . . . . . . . 200 713 Shaft Enclosures. . . . . . . . . . . . . . . . . . . . . . . . . 257 465 Control of Radiation Hazards. . . . . . . . . . . . . . . 203 714 Penetrations . . . . . . . . . . . . . . . . . . . . . . . . . . . . 259 466 Day Care Occupancies . . . . . . . . . . . . . . . . . . . . 207 715 Joints and Voids . . . . . . . . . . . . . . . . . . . . . . . . . 262 467 Hospice Inpatient Facilities and Units and Hospice Residential Facilities . . . . . . . . . . . . 209 716 Opening Protectives . . . . . . . . . . . . . . . . . . . . . . 262 717 Ducts and Air Transfer Openings . . . . . . . . . . . 269 468 Schools, Colleges and Universities . . . . . . . . . . 213 718 Concealed Spaces. . . . . . . . . . . . . . . . . . . . . . . . 274 469 Office Surgery Suite . . . . . . . . . . . . . . . . . . . . . . 215 719 Fire-Resistance Requirements for Plaster . . . . . 276 720 Thermal- and Sound-Insulating Materials . . . . . 276 721 Prescriptive Fire Resistance . . . . . . . . . . . . . . . . 277 722 Calculated Fire Resistance . . . . . . . . . . . . . . . . . 277 CHAPTER 5 GENERAL BUILDING HEIGHTS AND AREAS . . . . . . . . . . 221 Section 501 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 221 502 Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 221 503 General Building Height and Area Limitations . . . . . . . . . . . . . . . . . . . 221 504 Building Height and Number of Stories. . . . . . . 222 505 Mezzanines and Equipment Platforms . . . . . . . . 222 506 Building Area . . . . . . . . . . . . . . . . . . . . . . . . . . . 223 507 Unlimited Area Buildings. . . . . . . . . . . . . . . . . . 229 508 Mixed Use and Occupancy. . . . . . . . . . . . . . . . . 231 509 510 CHAPTER 8 Section 801 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 331 802 Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 331 803 Wall and Ceiling Finishes . . . . . . . . . . . . . . . . . 331 804 Interior Floor Finish . . . . . . . . . . . . . . . . . . . . . . 334 805 Combustible Materials in Types I and II Construction. . . . . . . . . . . . . . . . . . . . . 334 Incidental Uses . . . . . . . . . . . . . . . . . . . . . . . . . . 233 806 Decorative Materials and Trim . . . . . . . . . . . . . 334 Special Provisions . . . . . . . . . . . . . . . . . . . . . . . 234 807 Insulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 335 CHAPTER 6 TYPES OF CONSTRUCTION . . . . . 237 808 Acoustical Ceiling Systems . . . . . . . . . . . . . . . . 335 809 Artificial Decorative Vegetation on Buildings and in Outdoor Occupancies . . . . . . . . . . . . . 335 Section 601 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 237 602 Construction Classification . . . . . . . . . . . . . . . . 237 CHAPTER 9 603 Combustible Material in Types I and II Construction . . . . . . . . . . . . . . 238 Section vi INTERIOR FINISHES AND DECORATIVE MATERIALS . . . . . 331 901 FIRE PROTECTION SYSTEMS . . . 337 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 337 FLORIDA BUILDING CODE — BUILDING, 8th EDITION (2023) Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 TABLE OF CONTENTS 902 Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 337 1023 903 Automatic Sprinkler Systems . . . . . . . . . . . . . . . 338 1024 Exit Passageways . . . . . . . . . . . . . . . . . . . . . . . . 411 904 Alternative Automatic Fire-Extinguishing Systems . . . . . . . . . . . . . . 345 1025 Luminous Egress Path Markings . . . . . . . . . . . . 411 1026 Horizontal Exits . . . . . . . . . . . . . . . . . . . . . . . . . 413 905 Standpipe Systems . . . . . . . . . . . . . . . . . . . . . . . 347 1027 Exterior Exit Stairways and Ramps . . . . . . . . . . 413 906 Portable Fire Extinguishers . . . . . . . . . . . . . . . . 350 1028 Exit Discharge . . . . . . . . . . . . . . . . . . . . . . . . . . 414 907 Fire Alarm and Detection Systems. . . . . . . . . . . 351 1029 Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 415 908 Emergency Alarm Systems . . . . . . . . . . . . . . . . 362 1030 Emergency Escape and Rescue . . . . . . . . . . . . . 422 909 Smoke Control Systems . . . . . . . . . . . . . . . . . . . 363 1031 Egress Courts . . . . . . . . . . . . . . . . . . . . . . . . . . . 423 910 Smoke and Heat Removal . . . . . . . . . . . . . . . . . 371 911 Fire Command Center . . . . . . . . . . . . . . . . . . . . 372 CHAPTER 11 ACCESSIBILITY . . . . . . . . . . . . . . . . 425 912 Fire Department Connections. . . . . . . . . . . . . . . 373 Section 913 Fire Pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 374 1101 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 425 914 Emergency Responder Safety Features . . . . . . . 375 1102 Definitions (Reserved) . . . . . . . . . . . . . . . . . . . . 425 915 Carbon Monoxide Detection . . . . . . . . . . . . . . . 375 1103 Scoping Requirements (Reserved). . . . . . . . . . . 425 916 Gas Detection Systems . . . . . . . . . . . . . . . . . . . . 375 1104 Accessible Route (Reserved) . . . . . . . . . . . . . . . 425 917 Emergency Responder Radio Coverage. . . . . . . 376 1105 Accessible Entrances (Reserved) . . . . . . . . . . . . 425 1106 Parking and Passenger Loading Facilities (Reserved) . . . . . . . . . . . . 425 1107 Dwelling Units and Sleeping Units (Reserved) . . . . . . . . . . . . . . . 425 CHAPTER 10 MEANS OF EGRESS . . . . . . . . . . . . . 377 Section Interior Exit Stairways and Ramps . . . . . . . . . . 409 1001 Administration . . . . . . . . . . . . . . . . . . . . . . . . . . 377 1002 Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 377 1108 Special Occupancies (Reserved) . . . . . . . . . . . . 425 1003 General Means of Egress . . . . . . . . . . . . . . . . . . 377 1109 Other Features and Facilities (Reserved) . . . . . . 425 1004 Occupant Load . . . . . . . . . . . . . . . . . . . . . . . . . . 379 1110 Recreational Facilities (Reserved) . . . . . . . . . . . 425 1005 Means of Egress Sizing . . . . . . . . . . . . . . . . . . . 380 1111 Signage (Reserved) . . . . . . . . . . . . . . . . . . . . . . 425 1006 Number of Exits and Exit Access Doorways . . . . . . . . . . . . . . . . . . 381 CHAPTER 12 INTERIOR ENVIRONMENT . . . . . 427 Exit and Exit Access Doorway Configuration . . . . . . . . . . . . . . . . . 384 Section 1201 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 427 1008 Means of Egress Illumination. . . . . . . . . . . . . . . 385 1202 Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 427 1009 Accessible Means of Egress . . . . . . . . . . . . . . . . 386 1203 Ventilation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 427 1010 Doors, Gates and Turnstiles . . . . . . . . . . . . . . . . 386 1204 Temperature Control . . . . . . . . . . . . . . . . . . . . . 430 1011 Stairways . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 396 1205 Lighting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 430 1012 Ramps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 399 1206 Yards or Courts . . . . . . . . . . . . . . . . . . . . . . . . . 430 1013 Exit Signs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 400 1207 Sound Transmission. . . . . . . . . . . . . . . . . . . . . . 431 1014 Handrails. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 401 1208 Interior Space Dimensions . . . . . . . . . . . . . . . . . 431 1015 Guards. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 403 1209 Access to Unoccupied Spaces . . . . . . . . . . . . . . 431 1016 Exit Access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 404 1210 Toilet and Bathroom Requirements . . . . . . . . . . 432 1017 Exit Access Travel Distance. . . . . . . . . . . . . . . . 405 1211 Enhanced Classroom Acoustics . . . . . . . . . . . . . 432 1018 Aisles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 405 1019 Exit Access Stairways and Ramps . . . . . . . . . . . 406 CHAPTER 13 ENERGY EFFICIENCY . . . . . . . . . . 433 1020 Corridors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 407 Section 1021 Egress Balconies. . . . . . . . . . . . . . . . . . . . . . . . . 408 1301 1022 Exits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 408 1007 FLORIDA BUILDING CODE — BUILDING, 8th EDITION (2023) General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 433 vii Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 TABLE OF CONTENTS CHAPTER 14 EXTERIOR WALLS . . . . . . . . . . . . . 435 1521 High-Velocity Hurricane Zones—Reroofing. . . 479 Section 1522 High-Velocity Hurricane Zones—Rooftop Structures and Components . . . . . . . . . . . . . . 480 1401 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 435 1402 Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 435 1523 High-Velocity Hurricane Zones—Testing. . . . . 481 1403 Performance Requirements . . . . . . . . . . . . . . . . 435 1524 1404 Materials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 436 High-Velocity Hurricane Zones—Required Owner’s Notification for Roofing Considerations . . . . . . . . . . . . . . . . . . . . . . . . 484 1405 Installation of Wall Coverings . . . . . . . . . . . . . . 437 1525 1406 Combustible Materials on the Exterior Side of Exterior Walls . . . . . . . . . . . 444 High-Velocity Hurricane Zones—Uniform Permit Application . . . . . . . . . . . . . . . . . . . . . . . 486 1407 Metal Composite Materials (MCM). . . . . . . . . . 445 CHAPTER 16 STRUCTURAL DESIGN. . . . . . . . . . 491 1408 Exterior Insulation and Finish Systems (EIFS) . . . . . . . . . . . . . . . . . . 446 Section 1409 High-Pressure Decorative Exterior-Grade Compact Laminates (HPL). . . . . . . . . . . . . . . 446 1602 Definitions and Notations . . . . . . . . . . . . . . . . . 491 1603 Construction Documents . . . . . . . . . . . . . . . . . . 491 1604 General Design Requirements . . . . . . . . . . . . . . 492 1605 Load Combinations . . . . . . . . . . . . . . . . . . . . . . 494 CHAPTER 15 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES . . . . . . . . 451 1606 Dead Loads . . . . . . . . . . . . . . . . . . . . . . . . . . . . 496 1607 Live Loads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 496 Section 1410 Soffits and Facias at Roof Overhangs . . . . . . . . 447 1411 Plastic Composite Decking. . . . . . . . . . . . . . . . . 450 1601 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 491 1608 Snow Loads (Reserved) . . . . . . . . . . . . . . . . . . . 505 1501 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 451 1609 Wind Loads . . . . . . . . . . . . . . . . . . . . . . . . . . . . 505 1502 Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 451 1610 Soil Loads and Hydrostatic Pressure . . . . . . . . . 512 1503 Weather Protection . . . . . . . . . . . . . . . . . . . . . . . 452 1611 Rain Loads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 513 1504 Performance Requirements . . . . . . . . . . . . . . . . 453 1612 Flood Loads . . . . . . . . . . . . . . . . . . . . . . . . . . . . 514 1505 Fire Classification. . . . . . . . . . . . . . . . . . . . . . . . 454 1613 Earthquake Loads (Reserved) . . . . . . . . . . . . . . 518 1506 Materials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 455 1614 Atmospheric Ice Loads . . . . . . . . . . . . . . . . . . . 518 1507 Requirements for Roof Coverings . . . . . . . . . . . 455 1615 Structural Integrity . . . . . . . . . . . . . . . . . . . . . . . 518 1508 Roof Insulation . . . . . . . . . . . . . . . . . . . . . . . . . . 462 1616 1509 Roof Coatings. . . . . . . . . . . . . . . . . . . . . . . . . . . 463 1510 Rooftop Structures . . . . . . . . . . . . . . . . . . . . . . . 463 High-Velocity Hurricane Zones— General, Deflection, Volume Changes and Minimum Loads . . . . . . . . . . . . . . . . . . . 520 1511 Existing Roofing. . . . . . . . . . . . . . . . . . . . . . . . . 466 1617 High-Velocity Hurricane Zones— Roof Drainage (Reserved) . . . . . . . . . . . . . . . 521 1512 High-Velocity Hurricane Zones—General. . . . . 467 1618 1513 High-Velocity Hurricane Zones—Definitions. . . 468 High-Velocity Hurricane Zones— Special Load Considerations . . . . . . . . . . . . . 521 1514 High-Velocity Hurricane Zones— Weather Protection . . . . . . . . . . . . . . . . . . . . . 470 1619 High-Velocity Hurricane Zones— Live Load Reductions (Reserved) . . . . . . . . . 521 1515 High-Velocity Hurricane Zones— Performance Requirements . . . . . . . . . . . . . . 471 1620 High-Velocity Hurricane Zones— Wind Loads . . . . . . . . . . . . . . . . . . . . . . . . . . 521 1516 High-Velocity Hurricane Zones— Fire Classification. . . . . . . . . . . . . . . . . . . . . . 471 1621 High-Velocity Hurricane Zones— Overturning Moment and Uplift . . . . . . . . . . 522 1517 High-Velocity Hurricane Zones—Materials . . . 472 1622 1518 High-Velocity Hurricane Zones—Roof Coverings with Slopes 2:12 or Greater . . . . . 473 High-Velocity Hurricane Zones— Screen Enclosures . . . . . . . . . . . . . . . . . . . . . 522 1623 1519 High-Velocity Hurricane Zones—Roof Coverings with Slopes Less than 2:12 . . . . . . 476 High-Velocity Hurricane Zones— Live Loads Posted and Occupancy Permits (Reserved) . . . . . . . . . . . . . . . . . . . . . . . . . . . 522 1520 High-Velocity Hurricane Zones— Roof Insulation . . . . . . . . . . . . . . . . . . . . . . . . 478 1624 High-Velocity Hurricane Zones— Foundation Design (Reserved). . . . . . . . . . . . 522 viii FLORIDA BUILDING CODE — BUILDING, 8th EDITION (2023) Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 TABLE OF CONTENTS 1625 High-Velocity Hurricane Zones— Load Tests . . . . . . . . . . . . . . . . . . . . . . . . . . . 522 1821 High-Velocity Hurricane Zones— Monolithic Footings (Reserved) . . . . . . . . . . 559 1626 High-Velocity Hurricane Zones— Impact Tests for Wind-Borne Debris . . . . . . . 523 1822 High-Velocity Hurricane Zones— Pile Foundations (Reserved) . . . . . . . . . . . . . 559 1823 High-Velocity Hurricane Zones— Wood Piles (Reserved). . . . . . . . . . . . . . . . . . 559 1824 High-Velocity Hurricane Zones— Precast Concrete Piles (Reserved) . . . . . . . . . 559 1825 High-Velocity Hurricane Zones— Prestressed Precast Concrete Piles (Reserved) . . . . . . . . . . . . . . . 559 1826 High-Velocity Hurricane Zones— Cast-in-Place (Reserved) . . . . . . . . . . . . . . . . 559 1827 High-Velocity Hurricane Zones— Rolled Structural Shapes (Reserved) . . . . . . . 559 1828 High-Velocity Hurricane Zones— Special Piles or Special Conditions (Reserved) . . . . . . . . . . . . . . . . . . 559 1829 High-Velocity Hurricane Zones— Load Tests on Piles (Reserved) . . . . . . . . . . . 559 1830 High-Velocity Hurricane Zones— Foundation Walls and Grade Beams (Reserved) . . . . . . . . . . . . . . . . 559 1831 High-Velocity Hurricane Zones— Grades Under Buildings (Reserved) . . . . . . . 559 1832 High-Velocity Hurricane Zones— Retaining Walls (Reserved) . . . . . . . . . . . . . . 559 1833 High-Velocity Hurricane Zones— Seawalls and Bulkheads (Reserved) . . . . . . . 559 1834 High-Velocity Hurricane Zones— Soil Improvement (Reserved) . . . . . . . . . . . . 559 CHAPTER 17 SPECIAL INSPECTIONS AND TESTS . . . . . . . . . . . . . . . . . . . . . 527 Section 1701 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 527 1702 Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 527 1703 Approvals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 527 1704 Special Inspections and Tests, Contractor Responsibility and Structural Observation (Reserved) . . . . . 528 1705 Required Special Inspections and Tests (Reserved) . . . . . . . . . . . . . . . . . . . 528 1706 Design Strengths of Materials . . . . . . . . . . . . . . 528 1707 Alternative Test Procedure . . . . . . . . . . . . . . . . . 528 1708 In-Situ Load Tests . . . . . . . . . . . . . . . . . . . . . . . 528 1709 Preconstruction Load Tests . . . . . . . . . . . . . . . . 529 1710 Anchorage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 532 CHAPTER 18 SOILS AND FOUNDATIONS . . . . . . 535 Section 1801 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 535 1802 Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 535 1803 Geotechnical Investigations . . . . . . . . . . . . . . . . 535 1804 Excavation, Grading and Fill . . . . . . . . . . . . . . . 537 1805 Dampproofing and Waterproofing . . . . . . . . . . . 537 1806 Presumptive Load-bearing Values of Soils . . . . 539 1807 Foundation Walls, Retaining Walls and Embedded Posts and Poles . . . . . . . . . . . . . . . 539 CHAPTER 19 CONCRETE . . . . . . . . . . . . . . . . . . . . 561 1808 Foundations . . . . . . . . . . . . . . . . . . . . . . . . . . . . 544 1901 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 561 1809 Shallow Foundations . . . . . . . . . . . . . . . . . . . . . 548 1902 Coordination of Terms . . . . . . . . . . . . . . . . . . . . 561 1810 Deep Foundations. . . . . . . . . . . . . . . . . . . . . . . . 549 1903 Specifications for Tests and Materials . . . . . . . . 561 1811 through 1815 Reserved . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 558 1904 Durability Requirements . . . . . . . . . . . . . . . . . . 561 1905 Modifications to ACI 318 . . . . . . . . . . . . . . . . . 562 1816 Termite Protection . . . . . . . . . . . . . . . . . . . . . . . 558 1906 Footings for Light-Frame Construction . . . . . . . 562 1817 High-Velocity Hurricane Zones— Excavations (Reserved) . . . . . . . . . . . . . . . . . . . 559 1907 Minimum Slab Provisions . . . . . . . . . . . . . . . . . 562 1818 High-Velocity Hurricane Zones— Bearing Capacity of Soil (Reserved) . . . . . . . . . 559 1908 Shotcrete. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 563 1909 Special Wind Provisions for Concrete . . . . . . . . 563 1819 High-Velocity Hurricane Zones— Soil Bearing Foundations (Reserved). . . . . . . 559 1910 through 1916 Reserved. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 563 1820 High-Velocity Hurricane Zones— Concrete Slabs on Fill (Reserved) . . . . . . . . . 559 1917 Lightweight Insulating Concrete Roofs . . . . . . . 563 1918 Reserved. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 564 FLORIDA BUILDING CODE — BUILDING, 8th EDITION (2023) Section ix Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 TABLE OF CONTENTS 1919 High-Velocity Hurricane Zones— General (Reserved). . . . . . . . . . . . . . . . . . . . . 564 2115 Special Wind Provisions for Masonry . . . . . . . . 583 2116 and 2117 Reserved. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 583 1920 High-Velocity Hurricane Zones— Standards (Reserved) . . . . . . . . . . . . . . . . . . . 564 2118 1921 High-Velocity Hurricane Zones— Definitions (Reserved) . . . . . . . . . . . . . . . . . . 565 High-Velocity Hurricane Zones— Design (Reserved) . . . . . . . . . . . . . . . . . . . . . 583 2119 1922 High-Velocity Hurricane Zones— Materials (Reserved) . . . . . . . . . . . . . . . . . . . 565 High-Velocity Hurricane Zones— Quality, Tests and Approvals. . . . . . . . . . . . . 583 2120 1923 High-Velocity Hurricane Zones— Concrete Quality (Reserved) . . . . . . . . . . . . . 565 High-Velocity Hurricane Zones— Allowable Unit Stresses in Unit Masonry (Reserved). . . . . . . . . . . . . . . . . . . . 584 1924 High-Velocity Hurricane Zones— Mixing and Placing Concrete (Reserved). . . . 565 2121 High-Velocity Hurricane Zones— Construction Details. . . . . . . . . . . . . . . . . . . . 584 1925 High-Velocity Hurricane Zones— Formwork, Embedded Pipes and Construction Joints (Reserved). . . . . . . . . . . . 565 2122 High-Velocity Hurricane Zones— Reinforced Unit Masonry. . . . . . . . . . . . . . . . 587 1926 High-Velocity Hurricane Zones— Details of Reinforcement (Reserved) . . . . . . . 565 CHAPTER 22 STEEL . . . . . . . . . . . . . . . . . . . . . . . . . 589 1927 High-Velocity Hurricane Zones— Precast Concrete Units (Reserved). . . . . . . . . 565 2201 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 589 2202 Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 589 1928 High-Velocity Hurricane Zones— Prestressed Concrete (Reserved) . . . . . . . . . . 565 2203 Identification and Protection of Steel for Structural Purposes. . . . . . . . . . . . . . . . . . 589 1929 High-Velocity Hurricane Zones— Pneumatically Placed Concrete (Shotcrete) (Reserved) . . . . . . . . . . 565 2204 Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . 589 2205 Structural Steel. . . . . . . . . . . . . . . . . . . . . . . . . . 589 2206 Composite Structural Steel and Concrete Structures . . . . . . . . . . . . . . . . . . . . 589 Section CHAPTER 20 ALUMINUM . . . . . . . . . . . . . . . . . . . . 567 Section 2207 Steel Joists . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 589 2001 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 567 2208 Steel Cable Structures . . . . . . . . . . . . . . . . . . . . 590 2002 Materials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 567 2209 Steel Storage Racks . . . . . . . . . . . . . . . . . . . . . . 590 2003 High-Velocity Hurricane Zones—Aluminum . . . 569 2210 Cold-Formed Steel . . . . . . . . . . . . . . . . . . . . . . . 590 2211 Cold-Formed Steel Light-frame Construction . . . . . . . . . . . . . . . . . . . . . . . . . . 591 2212 Gable End Walls . . . . . . . . . . . . . . . . . . . . . . . . 591 2213 Reserved. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 591 2214 High-Velocity Hurricane Zones— General—Steel Construction . . . . . . . . . . . . . 591 2215 High-Velocity Hurricane Zones—Material . . . . 592 2216 High-Velocity Hurricane Zones— Design Loads . . . . . . . . . . . . . . . . . . . . . . . . . 592 2217 High-Velocity Hurricane Zones— Minimum Thickness of Material . . . . . . . . . . 592 2218 High-Velocity Hurricane Zones— Connections (Reserved) . . . . . . . . . . . . . . . . . 592 2219 High-Velocity Hurricane Zones— Tubular Columns . . . . . . . . . . . . . . . . . . . . . . 592 2220 High-Velocity Hurricane Zones— Protection of Metal (Reserved) . . . . . . . . . . . 593 2221 High-Velocity Hurricane Zones— General—Open Web Steel Joists. . . . . . . . . . 593 CHAPTER 21 MASONRY . . . . . . . . . . . . . . . . . . . . . 573 Section 2101 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 573 2102 Definitions and Notations. . . . . . . . . . . . . . . . . . 573 2103 Masonry Construction Materials . . . . . . . . . . . . 574 2104 Construction . . . . . . . . . . . . . . . . . . . . . . . . . . . . 575 2105 Quality Assurance . . . . . . . . . . . . . . . . . . . . . . . 575 2106 Seismic Design (Reserved). . . . . . . . . . . . . . . . . 575 2107 Allowable Stress Design. . . . . . . . . . . . . . . . . . . 575 2108 Strength Design of Masonry. . . . . . . . . . . . . . . . 576 2109 Dry-Stack Masonry . . . . . . . . . . . . . . . . . . . . . . 576 2110 Glass Unit Masonry . . . . . . . . . . . . . . . . . . . . . . 576 2111 Masonry Fireplaces . . . . . . . . . . . . . . . . . . . . . . 576 2112 Masonry Heaters. . . . . . . . . . . . . . . . . . . . . . . . . 578 2113 Masonry Chimneys. . . . . . . . . . . . . . . . . . . . . . . 579 2114 Termite Inspection . . . . . . . . . . . . . . . . . . . . . . . 583 x FLORIDA BUILDING CODE — BUILDING, 8th EDITION (2023) Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 TABLE OF CONTENTS 2222 High-Velocity Hurricane Zones— Cold-Formed Steel Construction . . . . . . . . . . 593 2327 High-Velocity Hurricane Zones— Fire-Retardant Wood (Reserved) . . . . . . . . . . 641 2223 High-Velocity Hurricane Zones— Preengineered, Prefabricated Metal Building Systems and Components (Preengineered Structures) . . . . . . . . . . . . . . . 594 2328 High-Velocity Hurricane Zones— Wood Fences . . . . . . . . . . . . . . . . . . . . . . . . . 641 2329 High-Velocity Hurricane Zones— Fire-Retardant-Treated Shakes and Shingles (Reserved) . . . . . . . . . . 641 2330 High-Velocity Hurricane Zones— Wood Blocking . . . . . . . . . . . . . . . . . . . . . . . 641 2224 High-Velocity Hurricane Zones— Chain Link Fences . . . . . . . . . . . . . . . . . . . . . 595 CHAPTER 23 WOOD . . . . . . . . . . . . . . . . . . . . . . . . . 597 CHAPTER 24 GLASS AND GLAZING . . . . . . . . . . 643 Section 2301 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 597 Section 2302 Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 597 2401 2303 Minimum Standards and Quality . . . . . . . . . . . . 597 2402 Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 643 2304 General Construction Requirements. . . . . . . . . . 606 2403 General Requirements for Glass . . . . . . . . . . . . 643 2305 General Design Requirements for Lateral Force-Resisting Systems . . . . . . . . . . 620 2404 Wind and Dead Loads on Glass. . . . . . . . . . . . . 643 2405 Sloped Glazing and Skylights . . . . . . . . . . . . . . 645 Allowable Stress Design. . . . . . . . . . . . . . . . . . . 621 2406 Safety Glazing . . . . . . . . . . . . . . . . . . . . . . . . . . 646 2307 Load and Resistance Factor Design . . . . . . . . . . 628 2407 Glass in Handrails and Guards. . . . . . . . . . . . . . 648 2308 Conventional Light-Frame Construction (Reserved). . . . . . . . . . . . . . . . . 628 2408 Glazing in Athletic Facilities . . . . . . . . . . . . . . . 649 2409 Glass in Walkways, Elevator Hoistways and Elevator Cars . . . . . . . . . . . . . . . . . . . . . . 649 2410 High-Velocity Hurricane Zones—General . . . . 650 2411 High-Velocity Hurricane Zones— Windows, Doors, Glass and Glazing . . . . . . . 650 2306 2309 Wood Frame Construction Manual . . . . . . . . . . 628 2310 through 2313 Reserved . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 629 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 643 2314 High-Velocity Hurricane Zones . . . . . . . . . . . . . 629 2315 High-Velocity Hurricane Zones—Quality . . . . . 630 2412 2316 High-Velocity Hurricane Zones— Sizes (Reserved) . . . . . . . . . . . . . . . . . . . . . . . 631 High-Velocity Hurricane Zones— Glass Veneer . . . . . . . . . . . . . . . . . . . . . . . . . 652 2413 2317 High-Velocity Hurricane Zones— Unit Stresses . . . . . . . . . . . . . . . . . . . . . . . . . . 631 High-Velocity Hurricane Zones—Storm Shutters/External Protective Devices. . . . . . . 653 2414 2318 High-Velocity Hurricane Zones— Vertical Framing. . . . . . . . . . . . . . . . . . . . . . . 631 High-Velocity Hurricane Zones— Curtain Walls . . . . . . . . . . . . . . . . . . . . . . . . . 653 2415 High-Velocity Hurricane Zones— Structural Glazing Systems . . . . . . . . . . . . . . 654 2319 High-Velocity Hurricane Zones— Horizontal Framing . . . . . . . . . . . . . . . . . . . . 632 2320 High-Velocity Hurricane Zones— Firestops (Reserved). . . . . . . . . . . . . . . . . . . . 637 CHAPTER 25 GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER . . . . . . . . . . . . . . . . . 657 2321 High-Velocity Hurricane Zones— Anchorage. . . . . . . . . . . . . . . . . . . . . . . . . . . . 637 Section 2501 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 657 2322 High-Velocity Hurricane Zones— Sheathing . . . . . . . . . . . . . . . . . . . . . . . . . . . . 638 2502 Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 657 2323 High-Velocity Hurricane Zones— Furring (Reserved) . . . . . . . . . . . . . . . . . . . . . 640 2503 Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 657 2504 Vertical and Horizontal Assemblies . . . . . . . . . 657 2324 High-Velocity Hurricane Zones— Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . 640 2505 Shear Wall Construction . . . . . . . . . . . . . . . . . . 657 2506 Gypsum Board and Gypsum Panel Product Materials. . . . . . . . . . 657 2507 Lathing and Plastering . . . . . . . . . . . . . . . . . . . . 658 2508 Gypsum Construction . . . . . . . . . . . . . . . . . . . . 659 2509 Showers and Water Closets . . . . . . . . . . . . . . . . 660 2325 2326 High-Velocity Hurricane Zones— Wood Supporting Masonry . . . . . . . . . . . . . . 640 High-Velocity Hurricane Zones— Protection of Wood. . . . . . . . . . . . . . . . . . . . . 640 FLORIDA BUILDING CODE — BUILDING, 8th EDITION (2023) xi Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 TABLE OF CONTENTS 2510 Lathing and Furring for Cement Plaster (Stucco). . . . . . . . . . . . . . . . . . . . . . . . 660 CHAPTER 28 MECHANICAL SYSTEMS. . . . . . . . 681 2511 Interior Plaster . . . . . . . . . . . . . . . . . . . . . . . . . . 661 2801 2512 Exterior Plaster . . . . . . . . . . . . . . . . . . . . . . . . . . 661 2513 Exposed Aggregate Plaster. . . . . . . . . . . . . . . . . 662 CHAPTER 29 PLUMBING SYSTEMS . . . . . . . . . . . 683 2514 Reinforced Gypsum Concrete . . . . . . . . . . . . . . 663 Section 2515 High-Velocity Hurricane Zones— Lathing (Reserved) . . . . . . . . . . . . . . . . . . . . . 663 2516 High-Velocity Hurricane Zones— Plaster (Reserved). . . . . . . . . . . . . . . . . . . . . . 663 2517 High-Velocity Hurricane Zones— Stucco (Reserved). . . . . . . . . . . . . . . . . . . . . . 663 2518 High-Velocity Hurricane Zones— Gypsum Board Products and Accessory Items (Reserved) . . . . . . . . . . . . . . 663 2519 High-Velocity Hurricane Zones— Suspended and Furred Ceilings (Reserved). . . . . . . . . . . . . . . . . . . . . . . . . . . . 663 2520 High-Velocity Hurricane Zones— Asbestos (Reserved) . . . . . . . . . . . . . . . . . . . . 663 2521 High-Velocity Hurricane Zones— Tile (Reserved) . . . . . . . . . . . . . . . . . . . . . . . . 663 CHAPTER 26 PLASTIC . . . . . . . . . . . . . . . . . . . . . . . 665 Section 2601 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 665 2602 Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 665 2603 Foam Plastic Insulation . . . . . . . . . . . . . . . . . . . 665 2604 Interior Finish and Trim . . . . . . . . . . . . . . . . . . . 671 Section General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 681 2901 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 683 2902 Minimum Plumbing Facilities . . . . . . . . . . . . . . 683 2903 Installation of Fixtures . . . . . . . . . . . . . . . . . . . . 687 CHAPTER 30 ELEVATORS AND CONVEYING SYSTEMS . . . . . . . . . 689 Section 3001 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 689 3002 Hoistway Enclosures . . . . . . . . . . . . . . . . . . . . . 690 3003 Emergency Operations. . . . . . . . . . . . . . . . . . . . 691 3004 Conveying Systems . . . . . . . . . . . . . . . . . . . . . . 691 3005 Machine Rooms . . . . . . . . . . . . . . . . . . . . . . . . . 691 3006 Elevator Lobbies and Hoistway Opening Protection . . . . . . . . . . . . 692 3007 Fire Service Access Elevator . . . . . . . . . . . . . . . 693 3008 Occupant Evacuation Elevators . . . . . . . . . . . . . 695 3009 Elevator Accessibility Requirements for the Physically Handicapped . . . . . . . . . . . . . . 697 3010 Serial Numbers. . . . . . . . . . . . . . . . . . . . . . . . . . 697 3011 Electrolysis Protection for Underground Hydraulic Elevator Cylinders. . . . . . . . . . . . . 698 3012 Alterations to Electric and Hydraulic Elevators and Escalators . . . . . . . . . . . . . . . . 698 3013 Clearance Requirements between Elevator Doors for Elevators Inside a Private Residence. . . . . . . . . . . . . . . . . . . . . . 698 2605 Plastic Veneer. . . . . . . . . . . . . . . . . . . . . . . . . . . 671 2606 Light-Transmitting Plastics . . . . . . . . . . . . . . . . 672 2607 Light-Transmitting Plastic Wall Panels . . . . . . . 673 2608 Light-Transmitting Plastic Glazing . . . . . . . . . . 674 CHAPTER 31 SPECIAL CONSTRUCTION . . . . . . 701 2609 Light-Transmitting Plastic Roof Panels . . . . . . . 674 Section 2610 Light-Transmitting Plastic Skylight Glazing . . . 675 3101 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 701 2611 Light-Transmitting Plastic Interior Signs. . . . . . 675 3102 Membrane Structures . . . . . . . . . . . . . . . . . . . . . 701 2612 Plastic Composites . . . . . . . . . . . . . . . . . . . . . . . 676 3103 Temporary Structures. . . . . . . . . . . . . . . . . . . . . 702 2613 Fiber-Reinforced Polymer . . . . . . . . . . . . . . . . . 676 3104 Pedestrian Walkways and Tunnels . . . . . . . . . . 702 2614 Reflective Plastic Core Insulation . . . . . . . . . . . 677 3105 Awnings and Canopies. . . . . . . . . . . . . . . . . . . . 704 2615 High-Velocity Hurricane Zones—Plastics . . . . . 677 3106 Marquees . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 705 3107 Signs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 705 CHAPTER 27 ELECTRICAL. . . . . . . . . . . . . . . . . . . 679 3108 Telecommunication and Broadcast Towers. . . . 705 Section 3109 Structures Seaward of a Coastal Construction Control Line . . . . . . . . . . . . . . . . . . . . . . . . . . 705 3110 Automatic Vehicular Gates . . . . . . . . . . . . . . . . 708 2701 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 679 2702 Emergency and Standby Power Systems . . . . . . 679 xii FLORIDA BUILDING CODE — BUILDING, 8th EDITION (2023) Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 TABLE OF CONTENTS 3111 Solar Energy Systems. . . . . . . . . . . . . . . . . . . . . 708 3112 Deposit of Material in Tidewater Regulated . . . 709 3113 Lighting, Mirrors, Landscaping . . . . . . . . . . . . . 710 3114 Airport Noise . . . . . . . . . . . . . . . . . . . . . . . . . . . 710 3115 Exterior Elevated Flooring Systems. . . . . . . . . . 711 APPENDIX C FLORIDA STANDARD FOR MITIGATION OF RADON IN EXISTING BUILDINGS . . . . . . . . . . 765 APPENDIX D FIRE DISTRICTS . . . . . . . . . . . . . . . 773 Section CHAPTER 32 ENCROACHMENTS INTO THE PUBLIC RIGHT-OF-WAY . . . . . . . . 713 D101 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 773 D102 Building Restrictions . . . . . . . . . . . . . . . . . . . . . 773 Section D103 Changes to Buildings . . . . . . . . . . . . . . . . . . . . . 774 D104 Buildings Located Partially in the Fire District . . . . . . . . . . . . . . . . . . . . . . . . . . 774 D105 Exceptions to Restrictions in Fire District . . . . . 774 CHAPTER 33 SAFEGUARDS DURING CONSTRUCTION . . . . . . . . . . . . . . . 715 D106 Referenced Standards. . . . . . . . . . . . . . . . . . . . . 775 Section APPENDIX E FLORIDA STANDARD FOR RADON-RESISTANT NEW COMMERCIAL CONSTRUCTION . . . . . . . . . . . . . . . 777 3201 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 713 3202 Encroachments . . . . . . . . . . . . . . . . . . . . . . . . . . 713 3301 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 715 3302 Construction Safeguards. . . . . . . . . . . . . . . . . . . 715 3303 Demolition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 715 3304 Site Work . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 715 3305 Sanitary. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 716 3306 Protection of Pedestrians . . . . . . . . . . . . . . . . . . 716 3307 Protection of Adjoining Property . . . . . . . . . . . . 717 3308 Temporary Use of Streets, Alleys and Public Property . . . . . . . . . . . . . . . . . . . . . . . . 717 3309 Fire Extinguishers. . . . . . . . . . . . . . . . . . . . . . . . 717 3310 Means of Egress . . . . . . . . . . . . . . . . . . . . . . . . . 717 APPENDIX H SIGNS. . . . . . . . . . . . . . . . . . . . . . . . . . 793 3311 Standpipes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 718 Section 3312 Automatic Sprinkler System. . . . . . . . . . . . . . . . 718 H101 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 793 3313 Water Supply for Fire Protection . . . . . . . . . . . . 718 H102 Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 793 H103 Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 793 CHAPTER 34 RESERVED . . . . . . . . . . . . . . . . . . . . . 719 CHAPTER 35 REFERENCED STANDARDS . . . . . 721 CHAPTER 36 FLORIDA FIRE PREVENTION CODE . . . . . . . . . . . . 753 APPENDIX A EMPLOYEE QUALIFICATIONS . . . . . . . . . . . . . . 755 Section A101 Building Official Qualifications . . . . . . . . . . . . . 755 APPENDIX B CHAPTER 9B-52 F.A.C. FLORIDA STANDARD FOR PASSIVE RADON-RESISTANT CONSTRUCTION . . . . . . . . . . . . . . . 757 FLORIDA BUILDING CODE — BUILDING, 8th EDITION (2023) APPENDIX F RODENTPROOFING . . . . . . . . . . . . 789 Section F101 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 789 APPENDIX G FLOOD-RESISTANT CONSTRUCTION (Reserved) . . . . . 791 H104 Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . 793 H105 Design and Construction . . . . . . . . . . . . . . . . . . 794 H106 Electrical . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 794 H107 Combustible Materials . . . . . . . . . . . . . . . . . . . . 794 H108 Animated Devices . . . . . . . . . . . . . . . . . . . . . . . 794 H109 Ground Signs . . . . . . . . . . . . . . . . . . . . . . . . . . . 794 H110 Roof Signs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 795 H111 Wall Signs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 795 H112 Projecting Signs . . . . . . . . . . . . . . . . . . . . . . . . . 795 H113 Marquee Signs . . . . . . . . . . . . . . . . . . . . . . . . . . 796 H114 Portable Signs . . . . . . . . . . . . . . . . . . . . . . . . . . 796 H115 Referenced Standards. . . . . . . . . . . . . . . . . . . . . 796 xiii Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 TABLE OF CONTENTS APPENDIX I PATIO COVERS. . . . . . . . . . . . . . . . . 797 APPENDIX N BOARD OF APPEALS . . . . . . . . . . . 811 N101 Section I101 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 797 I102 Definition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 797 I103 Exterior Walls and Openings . . . . . . . . . . . . . . . 797 I104 Height . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 797 I105 Structural Provisions . . . . . . . . . . . . . . . . . . . . . 797 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 811 APPENDIX O PERFORMANCE-BASED APPLICATION. . . . . . . . . . . . . . . . . . 813 O101 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 813 INDEX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 815 APPENDIX J GRADING . . . . . . . . . . . . . . . . . . . . . . 799 Section J101 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 799 J102 Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 799 J103 Permits Required . . . . . . . . . . . . . . . . . . . . . . . . 799 J104 Permit Application and Submittals. . . . . . . . . . . 799 J105 Inspections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 800 J106 Excavations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 800 J107 Fills . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 800 J108 Setbacks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 800 J109 Drainage and Terracing . . . . . . . . . . . . . . . . . . . 800 J110 Erosion Control . . . . . . . . . . . . . . . . . . . . . . . . . 802 J111 Referenced Standards . . . . . . . . . . . . . . . . . . . . . 802 APPENDIX K ADMINISTRATIVE PROVISIONS . . . . . . . . . . . . . . . . . . . 803 Section K101 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 803 K102 Applicability . . . . . . . . . . . . . . . . . . . . . . . . . . . . 803 K103 Permits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 803 K104 Construction Documents . . . . . . . . . . . . . . . . . . 804 K105 Alternative Engineered Design. . . . . . . . . . . . . . 804 K106 Required Inspections . . . . . . . . . . . . . . . . . . . . . 804 K107 Prefabricated Construction . . . . . . . . . . . . . . . . . 804 K108 Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 805 K109 Reconnection . . . . . . . . . . . . . . . . . . . . . . . . . . . 805 K110 Condemning Electrical Systems. . . . . . . . . . . . . 805 K111 Electrical Provisions. . . . . . . . . . . . . . . . . . . . . . 805 APPENDIX L EARTHQUAKE RECORDING INSTRUMENTATION (Reserved). . . . . . . . . . . . . . . . . . . . . . . 807 APPENDIX M TSUNAMI-GENERATED FLOOD HAZARD . . . . . . . . . . . . . . . 809 M101 Tsunami-Generated Flood Hazard . . . . . . . . . . . 809 M102 Referenced Standards . . . . . . . . . . . . . . . . . . . . . 809 xiv FLORIDA BUILDING CODE — BUILDING, 8th EDITION (2023) Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 1 SCOPE AND ADMINISTRATION PART 1—SCOPE AND APPLICATION and/or appurtenances, including ventilating, heating, cooling, air-conditioning and refrigeration systems, incinerators and other energy-related systems. SECTION 101 SCOPE AND GENERAL REQUIREMENTS [A] 101.1 Title. These regulations shall be known as the Florida Building Code, hereinafter referred to as “this code.” [A] 101.4.3 Plumbing. The provisions of the Florida Building Code, Plumbing shall apply to the installation, alteration, repair and replacement of plumbing systems, including equipment, appliances, fixtures, fittings and appurtenances, and where connected to a water or sewage system and all aspects of a medical gas system. [A] 101.2 Scope. The provisions of this code shall apply to the construction, alteration, relocation, enlargement, replacement, repair, equipment, use and occupancy, location, maintenance, removal and demolition of every building or structure or any appurtenances connected or attached to such buildings or structures. Exceptions: 1. Detached one- and two-family dwellings and multiple single-family dwellings (townhouses) not more than three stories above grade plane in height with a separate means of egress, and their accessory structures not more than three stories above grade plane in height, shall comply with the Florida Building Code, Residential. 2. Code requirements that address snow loads and earthquake protection shall not be utilized or enforced. [A] 101.2.1 Appendices. Provisions in the appendices shall not apply unless specifically adopted. [A] 101.3 Intent. The purpose of this code is to establish the minimum requirements to provide a reasonable level of safety, public health and general welfare through structural strength, means of egress facilities, stability, sanitation, adequate light and ventilation, energy conservation, and safety to life and property from fire and other hazards attributed to the built environment and to provide a reasonable level of safety to fire fighters and emergency responders during emergency operations. [A] 101.4 Referenced codes. The other codes listed in Sections 101.4.1 through 101.4.9 and referenced elsewhere in this code shall be considered part of the requirements of this code to the prescribed extent of each such reference. [A] 101.4.1 Gas. The provisions of the Florida Building Code, Fuel Gas shall apply to the installation of gas piping from the point of delivery, gas appliances and related accessories as covered in this code. These requirements apply to gas piping systems extending from the point of delivery to the inlet connections of appliances and the installation and operation of residential and commercial gas appliances and related accessories. [A] 101.4.2 Mechanical. The provisions of the Florida Building Code, Mechanical shall apply to the installation, alterations, repairs and replacement of mechanical systems, including equipment, appliances, fixtures, fittings FLORIDA BUILDING CODE — BUILDING, 8th EDITION (2023) [A] 101.4.4 Property maintenance. Reserved. [A] 101.4.5 Fire prevention. For provisions related to fire prevention, refer to the Florida Fire Prevention Code. The Florida Fire Prevention Code shall apply to matters affecting or relating to structures, processes and premises from the hazard of fire and explosion arising from the storage, handling or use of structures, materials or devices; from conditions hazardous to life, property or public welfare in the occupancy of structures or premises; and from the construction, extension, repair, alteration or removal of fire suppression, and alarm systems or fire hazards in the structure or on the premises from occupancy or operation. [A] 101.4.6 Energy. The provisions of the Florida Building Code, Energy Conservation shall apply to all matters governing the design and construction of buildings for energy efficiency. [A] 101.4.7 Existing buildings. The provisions of the Florida Building Code, Existing Building shall apply to matters governing the repair, alteration, change of occupancy, addition to and relocation of existing buildings. 101.4.8 Accessibility. For provisions related to accessibility, refer to the Florida Building Code, Accessibility. 101.4.9 Manufactured buildings. For additional administrative and special code requirements, see Section 458, Florida Building Code, Building, and Rule 61-41 F.A.C. SECTION 102 APPLICABILITY [A] 102.1 General. Where there is a conflict between a general requirement and a specific requirement, the specific requirement shall be applicable. Where, in any specific case, different sections of this code specify different materials, methods of construction or other requirements, the most restrictive shall govern. 102.1.1 The Florida Building Code does not apply to, and no code enforcement action shall be brought with respect to, zoning requirements, land use requirements and owner specifications or programmatic requirements which do not pertain to and govern the design, construction, erection, alteration, modification, repair or demolition of public or 1 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 SCOPE AND ADMINISTRATION private buildings, structures or facilities or to programmatic requirements that do not pertain to enforcement of the Florida Building Code. Additionally, a local code enforcement agency may not administer or enforce the Florida Building Code, Building to prevent the siting of any publicly owned facility, including, but not limited to, correctional facilities, juvenile justice facilities, or state universities, community colleges, or public education facilities, as provided by law. (j) Temporary housing provided by the Department of Corrections to any prisoner in the state correctional system. 102.2 Building. The provisions of the Florida Building Code shall apply to the construction, erection, alteration, modification, repair, equipment, use and occupancy, location, maintenance, removal and demolition of every public and private building, structure or facility or floating residential structure, or any appurtenances connected or attached to such buildings, structures or facilities. Additions, alterations, repairs and changes of use or occupancy group in all buildings and structures shall comply with the provisions provided in the Florida Building Code, Existing Building. The following buildings, structures and facilities are exempt from the Florida Building Code as provided by law, and any further exemptions shall be as determined by the legislature and provided by law: 1. Is not rented or leased or used as a principal residence; (a) Building and structures specifically regulated and preempted by the federal government. (b) Railroads and ancillary facilities associated with the railroad. (c) Nonresidential farm buildings on farms. (d) Temporary buildings or sheds used exclusively for construction purposes. 2. Is not located within the 100-year flood plain according to the Federal Emergency Management Agency’s current Flood Insurance Rate Map; and 3. Is not connected to an off-site electric power or water supply. 102.2.1 In addition to the requirements of Sections 553.79 and 553.80, Florida Statutes, facilities subject to the provisions of Chapter 395, Florida Statutes, and Part II of Chapter 400, Florida Statutes, shall have facility plans reviewed and construction surveyed by the state agency authorized to do so under the requirements of Chapter 395, Florida Statutes, and Part II of Chapter 400, Florida Statutes, and the certification requirements of the federal government. 102.2.2 Residential buildings or structures moved into or within a county or municipality shall not be required to be brought into compliance with the state minimum building code in force at the time the building or structure is moved, provided: (e) Mobile or modular structures used as temporary offices, except that the provisions of Part II (Sections 553.501-553.513, Florida Statutes) relating to accessibility by persons with disabilities shall apply to such mobile or modular structures. 1. The building or structure is structurally sound and in occupiable condition for its intended use; (f) Those structures or facilities of electric utilities, as defined in Section 366.02, Florida Statutes, which are directly involved in the generation, transmission, or distribution of electricity. 3. The building is not substantially remodeled; (g) Temporary sets, assemblies, or structures used in commercial motion picture or television production, or any sound-recording equipment used in such production, on or off the premises. (h) Chickees constructed by the Miccosukee Tribe of Indians of Florida or the Seminole Tribe of Florida. As used in this paragraph, the term “chickee” means an open-sided wooden hut that has a thatched roof of palm or palmetto or other traditional materials, and that does not incorporate any electrical, plumbing, or other nonwood features. (i) Family mausoleums not exceeding 250 square feet (23 m2) in area which are prefabricated and assembled on site or preassembled and delivered on site and have walls, roofs, and a floor constructed of granite, marble, or reinforced concrete. 2 (k) A building or structure having less than 1,000 square feet (93 m2) which is constructed and owned by a natural person for hunting and which is repaired or reconstructed to the same dimension and condition as existed on January 1, 2011, if the building or structure: 2. The occupancy use classification for the building or structure is not changed as a result of the move; 4. Current fire code requirements for ingress and egress are met; 5. Electrical, gas and plumbing systems meet the codes in force at the time of construction and are operational and safe for reconnection; and 6. Foundation plans are sealed by a professional engineer or architect licensed to practice in this state, if required by the Florida Building Code, Building for all residential buildings or structures of the same occupancy class. 102.2.3 The building official shall apply the same standard to a moved residential building or structure as that applied to the remodeling of any comparable residential building or structure to determine whether the moved structure is substantially remodeled. The cost of the foundation on which the moved building or structure is placed shall not be included in the cost of remodeling for purposes of determining whether a moved building or structure has been substantially remodeled. FLORIDA BUILDING CODE — BUILDING, 8th EDITION (2023) Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 SCOPE AND ADMINISTRATION 102.2.4 This section does not apply to the jurisdiction and authority of the Department of Agriculture and Consumer Services to inspect amusement rides or the Department of Financial Services to inspect state-owned buildings and boilers. 102.2.5 Each enforcement district shall be governed by a board, the composition of which shall be determined by the affected localities. 1. At its own option, each enforcement district or local enforcement agency may adopt rules granting to the owner of a single-family residence one or more exemptions from the Florida Building Code relating to: a. Addition, alteration, or repairs performed by the property owner upon his or her own property, provided any addition or alteration shall not exceed 1,000 square feet (93 m2) or the square footage of the primary structure, whichever is less. b. Addition, alteration, or repairs by a nonowner within a specific cost limitation set by rule, provided the total cost shall not exceed $5,000 within any 12-month period. c. Building and inspection fees. 2. However, the exemptions under subparagraph 1 do not apply to single-family residences that are located in mapped flood hazard areas, as defined in the code, unless the enforcement district or local enforcement agency has determined that the work, which is otherwise exempt, does not constitute a substantial improvement, including the repair of substantial damage, of such single-family residences. 3. Each code exemption, as defined in sub-subparagraphs 1a, 1b, and 1c shall be certified to the local board 10 days prior to implementation and shall only be effective in the territorial jurisdiction of the enforcement district or local enforcement agency implementing it. 102.2.6 This section does not apply to swings and other playground equipment accessory to a one- or two-family dwelling. Exception: Electrical service to such playground equipment shall be in accordance with Chapter 27 of this code. [A] 102.3 Application of references. References to chapter or section numbers, or to provisions not specifically identified by number, shall be construed to refer to such chapter, section or provision of this code. [A] 102.4 Referenced codes and standards. The codes and standards referenced in this code shall be considered part of the requirements of this code to the prescribed extent of each such reference and as further regulated in Sections 102.4.1 and 102.4.2. FLORIDA BUILDING CODE — BUILDING, 8th EDITION (2023) [A] 102.4.1 Conflicts. Where conflicts occur between provisions of this code and referenced codes and standards, the provisions of this code shall apply. [A] 102.4.2 Provisions in referenced codes and standards. Where the extent of the reference to a referenced code or standard includes subject matter that is within the scope of this code or the Florida Codes listed in Section 101.4, the provisions of this code or the Florida Codes listed in Section 101.4, as applicable, shall take precedence over the provisions in the referenced code or standard. [A] 102.5 Partial invalidity. Reserved. [A] 102.6 Existing structures. The legal occupancy of any structure existing on the date of adoption of this code shall be permitted to continue without change, except as otherwise specifically provided in this code, the Florida Building Code, Existing Building or the Florida Fire Prevention Code. [A] 102.6.1 Buildings not previously occupied. A building or portion of a building that has not been previously occupied or used for its intended purpose in accordance with the laws in existence at the time of its completion shall comply with the provisions of the Florida Building Code, Building or Florida Building Code, Residential, as applicable, for new construction or with any current permit for such occupancy. [A] 102.6.2 Buildings previously occupied. The legal occupancy of any building existing on the date of adoption of this code shall be permitted to continue without change, except as otherwise specifically provided in this code, the Florida Fire Prevention Code or as is deemed necessary by the building official for the general safety and welfare of the occupants and the public. 102.7 Relocation of manufactured buildings. (1) Relocation of an existing manufactured building does not constitute an alteration. (2) A relocated building shall comply with wind speed requirements of the new location, using the appropriate wind speed map. If the existing building was manufactured in compliance with the Standard Building Code (prior to March 1, 2002), the wind speed map of the Standard Building Code shall be applicable. If the existing building was manufactured in compliance with the Florida Building Code (after March 1, 2002), the wind speed map of the Florida Building Code shall be applicable. (3) A relocated building shall comply with the flood hazard area requirements of the new location, if applicable. 102.8 Existing mechanical equipment. An agency or local government may not require that existing mechanical equipment located on or above the surface of a roof be installed in compliance with the requirements of the Florida Building Code except during reroofing when the equipment is being replaced or moved and is not in compliance with the provisions of the Florida Building Code relating to roof-mounted mechanical units. 3 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 SCOPE AND ADMINISTRATION PART 2—ADMINISTRATION AND ENFORCEMENT SECTION 103 DEPARTMENT OF BUILDING SAFETY RESERVED SECTION 104 DUTIES AND POWERS OF BUILDING OFFICIAL [A] 104.1 General. Reserved. [A] 104.2 Applications and permits. Reserved. [A] 104.2.1 Determination of substantially improved or substantially damaged existing buildings and structures in flood hazard areas. Reserved. [A] 104.3 Notices and orders. Reserved. [A] 104.4 Inspections. Reserved. [A] 104.5 Identification. Reserved. [A] 104.6 Right of entry. Reserved. [A] 104.7 Department records. Reserved. [A] 104.8 Liability. Reserved. [A] 104.8.1 Legal defense. Reserved. [A] 104.9 Approved materials and equipment. Materials, equipment and devices approved by the building official shall be constructed and installed in accordance with such approval. [A] 104.9.1 Used materials and equipment. The use of used materials that meet the requirements of this code for new materials is permitted. Used equipment and devices shall not be reused unless approved by the building official. [A] 104.10 Modifications. Reserved. [A] 104.10.1 Flood hazard areas. Reserved. [A] 104.11 Alternative materials, design and methods of construction and equipment. The provisions of this code are not intended to prevent the installation of any material or to prohibit any design or method of construction not specifically prescribed by this code, provided that any such alternative has been approved. An alternative material, design or method of construction shall be approved where the building official finds that the proposed alternative meets all of the following: 1. The alternative material, design or method of construction is satisfactory and complies with the intent of the provisions of this code. 2. The material, method or work offered is, for the purpose intended, not less than the equivalent of that prescribed in this code as it pertains to the following: 2.1. Quality. 2.2. Strength. 2.3. Effectiveness. 2.4. Fire resistance. 4 2.5. Durability. 2.6. Safety. Where the alternative material, design or method of construction is not approved, the building official shall respond in writing, stating the reasons why the alternative was not approved. [A] 104.11.1 Research reports. Supporting data, where necessary to assist in the approval of materials or assemblies not specifically provided for in this code, shall consist of valid research reports from approved sources. [A] 104.11.2 Tests. Whenever there is insufficient evidence of compliance with the provisions of this code, or evidence that a material or method does not conform to the requirements of this code, or in order to substantiate claims for alternative materials or methods, the building official shall have the authority to require tests as evidence of compliance to be made at no expense to the jurisdiction. Test methods shall be as specified in this code or by other recognized test standards. In the absence of recognized and accepted test methods, the building official shall approve the testing procedures. Tests shall be performed by an approved agency. Reports of such tests shall be retained by the building official for the period required for retention of public records. SECTION 105 PERMITS [A] 105.1 Required. Any owner or owner’s authorized agent who intends to construct, enlarge, alter, repair, move, demolish or change the occupancy of a building or structure, or to erect, install, enlarge, alter, repair, remove, convert or replace any impact-resistant coverings, electrical, gas, mechanical or plumbing system, the installation of which is regulated by this code, or to cause any such work to be performed, shall first make application to the building official and obtain the required permit. [A] 105.1.1 Annual facility permit. In lieu of an individual permit for each alteration to an existing electrical, gas, mechanical, plumbing or interior nonstructural office system(s), the building official is authorized to issue an annual permit for any occupancy to facilitate routine or emergency service, repair, refurbishing, minor renovations of service systems or manufacturing equipment installations/relocations. The building official shall be notified of major changes and shall retain the right to make inspections at the facility site as deemed necessary. An annual facility permit shall be assessed with an annual fee and shall be valid for one year from date of issuance. A separate permit shall be obtained for each facility and for each construction trade, as applicable. The permit application shall contain a general description of the parameters of work intended to be performed during the year. [A] 105.1.2 Annual permit records. The person to whom an annual permit is issued shall keep a detailed record of alterations made under such annual permit. The building FLORIDA BUILDING CODE — BUILDING, 8th EDITION (2023) Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 SCOPE AND ADMINISTRATION official shall have access to such records at all times or such records shall be filed with the building official as designated. 105.1.3 Food permit. In accordance with Section 500.12, Florida Statutes, a food permit from the Department of Agriculture and Consumer Services is required of any person who operates a food establishment or retail store. 105.1.4 Public swimming pool. The local enforcing agency may not issue a building permit to construct, develop, or modify a public swimming pool without proof of application, whether complete or incomplete, for an operating permit pursuant to Section 514.031, Florida Statutes. A certificate of completion or occupancy may not be issued until such operating permit is issued. The local enforcing agency shall conduct their review of the building permit application upon filing and in accordance with Chapter 553, Florida Statutes. The local enforcing agency may confer with the Department of Health, if necessary, but may not delay the building permit application review while awaiting comment from the Department of Health. [A] 105.2 Work exempt from permit. Exemptions from permit requirements of this code shall not be deemed to grant authorization for any work to be done in any manner in violation of the provisions of this code. Permits shall not be required for the following: Gas: 1. Portable heating appliance. 2. Replacement of any minor part that does not alter approval of equipment or make such equipment unsafe. Mechanical: 1. Portable heating appliance. 2. Portable ventilation equipment. 3. Portable cooling unit. 4. Steam, hot or chilled water piping within any heating or cooling equipment regulated by this code. 5. Replacement of any part that does not alter its approval or make it unsafe. 6. Portable evaporative cooler. 7. Self-contained refrigeration system containing 10 pounds (4.54 kg) or less of refrigerant and actuated by motors of 1 horsepower (0.75 kW) or less. 8. The installation, replacement, removal or metering of any load management control device. Plumbing: 1. The stopping of leaks in drains, water, soil, waste or vent pipe, provided, however, that if any concealed trap, drain pipe, water, soil, waste or vent pipe becomes defective and it becomes necessary to remove and replace the same with new material, such work shall be considered as new work and a permit shall be obtained and inspection made as provided in this code. FLORIDA BUILDING CODE — BUILDING, 8th EDITION (2023) 2. The clearing of stoppages or the repairing of leaks in pipes, valves or fixtures and the removal and reinstallation of water closets, provided such repairs do not involve or require the replacement or rearrangement of valves, pipes or fixtures. [A] 105.2.1 Emergency repairs. Where equipment replacements and repairs must be performed in an emergency situation, the permit application shall be submitted within the next working business day to the building official. [A] 105.2.2 Minor repairs. Ordinary minor repairs may be made with the approval of the building official without a permit, provided the repairs do not include the cutting away of any wall, partition or portion thereof, the removal or cutting of any structural beam or load-bearing support, or the removal or change of any required means of egress, or rearrangement of parts of a structure affecting the egress requirements; nor shall ordinary repairs include addition to, alteration of, replacement or relocation of any standpipe, water supply, sewer, drainage, drain leader, gas, soil, waste, vent or similar piping, electric wiring systems or mechanical equipment or other work affecting public health or general safety, and such repairs shall not violate any of the provisions of the technical codes. [A] 105.2.3 Public service agencies. Reserved. [A] 105.3 Application for permit. To obtain a permit, the applicant shall first file an application therefor in writing on a form furnished by the building department for that purpose. Permit application forms shall be in the format prescribed by a local administrative board, if applicable, and must comply with the requirements of Sections 713.135(5) and (6), Florida Statutes. Each application shall be inscribed with the date of application, and the code in effect as of that date. For a building permit for which an application is submitted prior to the effective date of the Florida Building Code, the state minimum building code in effect in the permitting jurisdiction on the date of the application governs the permitted work for the life of the permit and any extension granted to the permit. Effective October 1, 2017, a local enforcement agency shall post each type of building permit application on its website. Completed applications must be able to be submitted electronically to the appropriate building department. Accepted methods of electronic submission include, but are not limited to, e-mail submission of applications in portable document format or submission of applications through an electronic fill-in form available on the building department’s website or through a third-party submission management software. Payments, attachments, or drawings required as part of the permit application may be submitted in person in a nonelectronic format, at the discretion of the building official. [A] 105.3.1 Action on application. The building official shall examine or cause to be examined applications for permits and amendments thereto within a reasonable time after filing. If the application or the construction documents do not conform to the requirements of pertinent laws, the building official shall reject such application in 5 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 SCOPE AND ADMINISTRATION writing, stating the reasons therefor. If the building official is satisfied that the proposed work conforms to the requirements of this code and laws and ordinances applicable thereto, the building official shall issue a permit therefor as soon as practicable. When authorized through contractual agreement with a school board, in acting on applications for permits, the building official shall give first priority to any applications for the construction of, or addition or renovation to, any school or educational facility. 105.3.1.1 If a state university, Florida college or public school district elects to use a local government’s code enforcement offices, fees charged by counties and municipalities for enforcement of the Florida Building Code on buildings, structures, and facilities of state universities, state colleges, and public school districts shall not be more than the actual labor and administrative costs incurred for plans review and inspections to ensure compliance with the code. 105.3.1.2 No permit may be issued for any building construction, erection, alteration, modification, repair, or addition unless the applicant for such permit provides to the enforcing agency which issues the permit any of the following documents which apply to the construction for which the permit is to be issued and which shall be prepared by or under the direction of an engineer registered under Chapter 471, Florida Statutes: 1. Plumbing documents for any new building or addition which requires a plumbing system with more than 250 fixture units or which costs more than $125,000. 2. Fire sprinkler documents for any new building or addition which includes a fire sprinkler system which contains 50 or more sprinkler heads. Personnel as authorized by chapter 633 Florida Statutes, may design a new fire sprinkler system of 49 or fewer heads; may design the alteration of an existing fire sprinkler system if the alteration consists of the relocation, addition or deletion of 49 heads or fewer, notwithstanding the size of the existing fire sprinkler system; or may design the alteration of an existing fire sprinkler system if the alteration consists of the relocation or deletion of 249 or fewer sprinklers, notwithstanding the size of the existing fire sprinkler system, if there is no change of occupancy of the affected areas, as defined in this code and the Florida Fire Prevention Code, and there is no change in the water demand as defined in NFPA 13, “Standard for the Installation of Sprinkler Systems,” and if the occupancy hazard classification as defined in NFPA 13 is reduced or remains the same as a result of the alteration. 3. Heating, ventilation, and air-conditioning documents for any new building or addition which requires more than a 15-ton-per-system capacity which is designed to accommodate 100 or more persons or for which the system costs more than $125,000. This paragraph does not include any 6 document for the replacement or repair of an existing system in which the work does not require altering a structural part of the building or for work on a residential one-, two-, three-, or four-family structure. An air-conditioning system may be designed by an installing air-conditioning contractor certified under Chapter 489, Florida Statutes, to serve any building or addition which is designed to accommodate fewer than 100 persons and requires an air-conditioning system with a value of $125,000 or less; and when a 15-ton-per system or less is designed for a singular space of a building and each 15-ton system or less has an independent duct system. Systems not complying with the above require design documents that are to be sealed by a professional engineer. Example 1: When a space has two 10-ton systems with each having an independent duct system, the contractor may design these two systems since each unit (system) is less than 15 tons. Example 2: Consider a small single-story office building which consists of six individual offices where each office has a single three-ton package air conditioning heat pump. The six heat pumps are connected to a single water cooling tower. The cost of the entire heating, ventilation and air-conditioning work is $47,000 and the office building accommodates fewer than 100 persons. Because the six mechanical units are connected to a common water tower, this is considered to be an 18-ton system. Note: It was further clarified by the Commission that the limiting criteria of 100 persons and $125,000 apply to the building occupancy load and the cost for the total air-conditioning system of the building. 4. Any specialized mechanical, electrical, or plumbing document for any new building or addition which includes a medical gas, oxygen, steam, vacuum, toxic air filtration, halon, or fire detection and alarm system which costs more than $5,000. Exception: Simplified permitting process for fire alarm system projects. (1) As used in this section, the term: (a) “Contractor” means a person who is qualified to engage in the business of electrical or alarm system contracting pursuant to a certificate or registration issued by the department under Part II of Chapter 489, Florida Statutes. (b) “Fire alarm system project” means a fire alarm system alteration of a FLORIDA BUILDING CODE — BUILDING, 8th EDITION (2023) Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 SCOPE AND ADMINISTRATION the request, the local government must, within 15 days after receiving such information: total of 20 or fewer initiating devices and notification devices, or the installation or replacement of a fire communicator connected to an existing fire alarm control panel in an existing commercial, residential, apartment, cooperative or condominium building. (2) A local enforcement agency: (a) May require a contractor, as a condition of obtaining a permit for a fire alarm system project, to submit a completed application and payment. 3. (b) May not require a contractor to submit plans or specifications as a condition of obtaining a permit for a fire alarm system project. (3) A local enforcement agency must issue a permit for a fire alarm system project in person or electronically. (4) A local enforcement agency must require at least one inspection of a fire alarm system project to ensure compliance with applicable codes and standards. If a fire alarm system project fails an inspection, the contractor must take corrective action as necessary to pass inspection. (5) A contractor must keep a copy of the plans and specifications at a fire alarm system project worksite and make such plans and specifications available to the inspector at each inspection. 4. 5. Electrical documents. See Florida Statutes 471.003(2)(h). Documents requiring an engineer seal by this part shall not be valid unless a professional engineer who possesses a valid certificate of registration has signed, dated, and stamped such document as provided in Section 471.025, Florida Statutes. 6. All public swimming pools and public bathing places defined by and regulated under Chapter 514, Florida Statutes. 105.3.1.3 Reviewing application for building permit. 1. When reviewing an application for a building permit, a local government may not request additional information from the applicant more than three times, unless the applicant waives such limitation in writing. 2. If a local government requests additional information from an applicant and the applicant submits the requested additional information to the local government within 30 days after receiving FLORIDA BUILDING CODE — BUILDING, 8th EDITION (2023) a. Determine if the application is properly completed; b. Approve the application; c. Approve the application with conditions; d. Deny the application; or e. Advise the applicant of information, if any, that is needed to deem the application properly completed or to determine the sufficiency of the application. If a local government makes a second request for additional information from the applicant and the applicant submits the requested additional information to the local government within 30 days after receiving the request, the local government must, within 10 days after receiving such information: a. Determine if the application is properly completed; b. Approve the application; c. Approve the application with conditions; d. Deny the application; or e. Advise the applicant of information, if any, that is needed to deem the application properly completed or to determine the sufficiency of the application. Before a third request for additional information may be made, the applicant must be offered an opportunity to meet with the local government to attempt to resolve outstanding issues. If a local government makes a third request for additional information from the applicant and the applicant submits the requested additional information to the local government within 30 days after receiving the request, the local government must, within 10 days after receiving such information unless the applicant waived the local government's limitation in writing, determine that the application is complete and: a. Approve the application; b. Approve the application with conditions; or c. Deny the application. 5. If the applicant believes the request for additional information is not authorized by ordinance, rule, statute, or other legal authority, the local government, at the applicant’s request, must process the application and either approve the application, approve the application with conditions, or deny the application. [A] 105.3.2 Time limitation of application. An application for a permit for any proposed work shall be deemed to have been abandoned 180 days after the date of filing, 7 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 SCOPE AND ADMINISTRATION unless such application has been pursued in good faith or a permit has been issued; except that the building official is authorized to grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. 105.3.3 An enforcing authority may not issue a building permit for any building construction, erection, alteration, modification, repair or addition unless the permit either includes on its face or there is attached to the permit the following statement: “NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies.” 105.3.4 A building permit for a single-family residential dwelling must be issued within 30 working days of application therefor unless unusual circumstances require a longer time for processing the application or unless the permit application fails to satisfy the Florida Building Code or the enforcing agency’s laws or ordinances. 105.3.5 Identification of minimum premium policy. Except as otherwise provided in Chapter 440, Florida Statutes, Workers’ Compensation, every employer shall, as a condition to receiving a building permit, show proof that it has secured compensation for its employees as provided in Sections 440.10 and 440.38, Florida Statutes. 105.3.6 Asbestos removal. Moving, removal or disposal of asbestos-containing materials on a residential building where the owner occupies the building, the building is not for sale or lease, and the work is performed according to the owner-builder limitations provided in this paragraph. To qualify for exemption under this paragraph, an owner must personally appear and sign the building permit application. The permitting agency shall provide the person with a disclosure statement in substantially the following form: Disclosure Statement: State law requires asbestos abatement to be done by licensed contractors. You have applied for a permit under an exemption to that law. The exemption allows you, as the owner of your property, to act as your own asbestos abatement contractor even though you do not have a license. You must supervise the construction yourself. You may move, remove or dispose of asbestos-containing materials on a residential building where you occupy the building and the building is not for sale or lease, or the building is a farm outbuilding on your property. If you sell or lease such building within 1 year after the asbestos abatement is complete, the law will presume that you intended to sell or lease the property at the time the work was done, which is a violation of this exemption. You may not hire an unlicensed person as your contractor. Your work must be done according to all local, state and federal laws and regulations which apply to asbestos abatement projects. It is your responsibility to make sure that people employed by you have licenses 8 required by state law and by county or municipal licensing ordinances. 105.3.7 Applicable Code for Manufactured Buildings. Manufacturers should be permitted to complete all buildings designed and approved prior to the effective date of a new code edition, provided a clear signed contract is in place. The contract shall provide specific data mirroring that required by an application for permit, specifically, without limitation, date of execution, building owner or dealer, and anticipated date of completion. However, the construction activity must commence within 6 months of the contract’s execution. The contract is subject to verification by the Department of Business and Professional Regulation. 105.3.8 A local government may not require a contract between a builder and an owner for the issuance of a building permit or as a requirement for the submission of a building permit application. 105.4 Conditions of the permit. 105.4.1 Permit intent. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter or set aside any of the provisions of the technical codes, nor shall issuance of a permit prevent the building official from thereafter requiring a correction of errors in plans, construction or violations of this code. Every permit issued shall become invalid unless the work authorized by such permit is commenced within 6 months after its issuance, or if the work authorized by such permit is suspended or abandoned for a period of 6 months after the time the work is commenced. 105.4.1.1 If work has commenced and the permit is revoked, becomes null and void, or expires because of lack of progress or abandonment, a new permit covering the proposed construction shall be obtained before proceeding with the work. 105.4.1.2 If a new permit is not obtained within 180 days from the date the initial permit became null and void, the building official is authorized to require that any work which has been commenced or completed be removed from the building site. Alternately, a new permit may be issued on application, providing the work in place and required to complete the structure meets all applicable regulations in effect at the time the initial permit became null and void and any regulations which may have become effective between the date of expiration and the date of issuance of the new permit. 105.4.1.3 Work shall be considered to be in active progress when the permit has received an approved inspection within 180 days. This provision shall not be applicable in case of civil commotion or strike or when the building work is halted due directly to judicial injunction, order or similar process. 105.4.1.4 The fee for renewal reissuance and extension of a permit shall be set forth by the administrative authority. 105.5 Additional options for closing a permit. Pursuant to Section 553.79(15), Florida Statutes, a property owner, FLORIDA BUILDING CODE — BUILDING, 8th EDITION (2023) Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 SCOPE AND ADMINISTRATION regardless of whether the property owner is the one listed on the application for the building permit, may close a building permit by complying with the following requirements: local enforcement agency shall maintain all rights and remedies against the property owner and contractor listed on the permit. 1. The property owner may retain the original contractor listed on the permit or hire a different contractor appropriately licensed in this state to perform the work necessary to satisfy the conditions of the permit and to obtain any necessary inspection in order to close the permit. If a contractor other than the original contractor listed on the permit is hired by the property owner to close the permit, such contractor is not liable for any defects in the work performed by the original contractor and is only liable for the work that he or she performs. Pursuant to Section 553.79(16), Florida Statutes, a local enforcement agency may not deny issuance of a building permit to a contractor solely because the contractor is listed on other building permits that were not closed. 2. The property owner may assume the role of an ownerbuilder, in accordance with Sections 489.103(7) and 489.503(6), Florida Statutes. 3. If a building permit is expired and its requirements have been substantially completed, as determined by the local enforcement agency, the permit may be closed without having to obtain a new building permit, and the work required to close the permit may be done pursuant to the building code in effect at the time the local enforcement agency received the application for the permit, unless the contractor has sought and received approval from the local enforcement agency for an alternative material, design or method of construction. 4. A local enforcement agency may close a building permit 6 years after the issuance of the permit, even in the absence of a final inspection, if the local enforcement agency determines that no apparent safety hazard exists. For purposes of this section, the term “close” means that the requirements of the permit have been satisfied. [A] 105.6 Denial or revocation. Whenever a permit required under this section is denied or revoked because the plan, or the construction, erection, alteration, modification, repair, or demolition of a building, is found by the local enforcing agency to be not in compliance with the Florida Building Code, the local enforcing agency shall identify the specific plan or project features that do not comply with the applicable codes, identify the specific code chapters and sections upon which the finding is based, and provide this information to the permit applicant. If the local building code administrator or inspector finds that the plans are not in compliance with the Florida Building Code, the local building code administrator or inspector shall identify the specific plan features that do not comply with the applicable codes, identify the specific code chapters and sections upon which the finding is based, and provide this information to the local enforcing agency. The local enforcing agency shall provide this information to the permit applicant. Pursuant to Section 553.79(16), Florida Statutes, a local enforcement agency may not deny issuance of a building permit to; issue a notice of violation to; or fine, penalize, sanction or assess fees against an arm’s-length purchaser of a property for value solely because a building permit applied for by a previous owner of the property was not closed. The FLORIDA BUILDING CODE — BUILDING, 8th EDITION (2023) [A] 105.7 Placement of permit. The building permit or copy shall be kept on the site of the work until the completion of the project. 105.8 Notice of commencement. In accordance with Section 713.135, Florida Statutes, when any person applies for a building permit, the authority issuing such permit shall print on the face of each permit card in no less than 14-point, capitalized, boldfaced type: “WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.” 105.9 Asbestos. The enforcing agency shall require each building permit for the demolition or renovation of an existing structure to contain an asbestos notification statement which indicates the owner’s or operator’s responsibility to comply with the provisions of Section 469.003, Florida Statutes, and to notify the Department of Environmental Protection of his or her intentions to remove asbestos, when applicable, in accordance with state and federal law. 105.10 Certificate of protective treatment for prevention of termites. A weather-resistant job-site posting board shall be provided to receive duplicate treatment certificates as each required protective treatment is completed, providing a copy for the person the permit is issued to and another copy for the building permit files. The treatment certificate shall provide the product used, identity of the applicator, time and date of the treatment, site location, area treated, chemical used, percent concentration and number of gallons used, to establish a verifiable record of protective treatment. If the soil chemical barrier method for termite prevention is used, final exterior treatment shall be completed prior to final building approval. 105.11 Notice of termite protection. A permanent sign which identifies the termite treatment provider and need for reinspection and treatment contract renewal shall be provided. The sign shall be posted near the water heater or electric panel. 105.12 Work starting before permit issuance. Upon approval of the building official, the scope of work delineated in the building permit application and plan may be started prior to the final approval and issuance of the permit, provided any work completed is entirely at risk of the permit applicant and the work does not proceed past the first required inspection. 9 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 SCOPE AND ADMINISTRATION 105.13 Phased permit approval. After submittal of the appropriate construction documents, the building official is authorized to issue a permit for the construction of foundations or any other part of a building or structure before the construction documents for the whole building or structure have been submitted. The holder of such permit for the foundation or other parts of a building or structure shall proceed at the holder’s own risk with the building operation and without assurance that a permit for the entire structure will be granted. Corrections may be required to meet the requirements of the technical codes. 105.14 Permit issued on basis of an affidavit. Whenever a permit is issued in reliance upon an affidavit or whenever the work to be covered by a permit involves installation under conditions which, in the opinion of the building official, are hazardous or complex, the building official shall require that the architect or engineer who signed the affidavit or prepared the drawings or computations shall supervise such work. In addition, they shall be responsible for conformity to the permit, provide copies of inspection reports as inspections are performed, and upon completion make and file with the building official written affidavit that the work has been done in conformity to the reviewed plans and with the structural provisions of the technical codes. In the event such architect or engineer is not available, the owner shall employ in his stead a competent person or agency whose qualifications are reviewed by the building official. The building official shall ensure that any person conducting plans review is qualified as a plans examiner under Part XII of Chapter 468, Florida Statutes, and that any person conducting inspections is qualified as a building inspector under Part XII of Chapter 468, Florida Statutes. 105.14.1 Affidavits in flood hazard areas. Permit issued on basis of an affidavit shall not extend to the flood load and flood resistance requirements of the Florida Building Code and the building official shall review and inspect those requirements. 105.15 Opening protection. When any activity requiring a building permit, not including roof covering replacement or repair work associated with the prevention of degradation of the residence, that is applied for on or after July 1, 2008, and for which the estimated cost is $50,000 or more for a site built single-family detached residential structure that is located in the wind-borne debris region as defined in this code and that has an insured value of $750,000 or more, or, if the site built single-family detached residential structure is uninsured or for which documentation of insured value is not presented, has a just valuation for the structure for purposes of ad valorem taxation of $750,000 or more; opening protections as required within this code or Florida Building Code, Residential for new construction shall be provided. Exception: Single family residential structures permitted subject to the Florida Building Code are not required to comply with this section. 105.16 Inspection of existing residential building not impacted by construction. (a) A local enforcing agency, and any local building code administrator, inspector, or other official or entity, 10 may not require as a condition of issuance of a one- or two-family residential building permit the inspection of any portion of a building, structure, or real property that is not directly impacted by the construction, erection, alteration, modification, repair, or demolition of the building, structure, or real property for which the permit is sought. (b) This subsection does not apply to a building permit sought for: 1. A substantial improvement as defined in s. 161.54, Florida Statutes or as defined in the Florida Building Code. 2. A change of occupancy as defined in the Florida Building Code. 3. A conversion from residential to nonresidential or mixed use pursuant to s. 553.507(2)(a), Florida Statutes or as defined in the Florida Building Code. 4. A historic building as defined in the Florida Building Code. (c) This subsection does not prohibit a local enforcing agency, or any local building code administrator, inspector, or other official or entity, from: 1. Citing any violation inadvertently observed in plain view during the ordinary course of an inspection conducted in accordance with the prohibition in paragraph (a). 2. Inspecting a physically nonadjacent portion of a building, structure, or real property that is directly impacted by the construction, erection, alteration, modification, repair, or demolition of the building, structure, or real property for which the permit is sought in accordance with the prohibition in paragraph (a). 3. Inspecting any portion of a building, structure, or real property for which the owner or other person having control of the building, structure, or real property has voluntarily consented to the inspection of that portion of the building, structure, or real property in accordance with the prohibition in paragraph (a). 4. Inspecting any portion of a building, structure, or real property pursuant to an inspection warrant issued in accordance with ss. 933.20-933.30, Florida Statutes. 105.17 Streamlined low-voltage alarm system installation permitting. (1) As used in this section, the term: (a) “Contractor” means a person who is qualified to engage in the business of electrical or alarm system contracting pursuant to a certificate or registration issued by the department under Part II of Chapter 489, Florida Statutes. (b) “Low-voltage alarm system project” means a project related to the installation, maintenance, inspection, replacement, or service of a new or existing FLORIDA BUILDING CODE — BUILDING, 8th EDITION (2023) Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 SCOPE AND ADMINISTRATION alarm system, as defined in s. 489.505, Florida Statutes, including video cameras and closed-circuit television systems used to signal or detect a burglary, fire, robbery or medical emergency, that is hardwired and operating at low voltage, as defined in the National Electrical Code Standard 70, Current Edition, or a new or existing low-voltage electric fence. The term also includes ancillary components or equipment attached to a low-voltage alarm system or low-voltage electric fence, including, but not limited to, home-automation equipment, thermostats, closed-circuit television systems, access controls, battery recharging devices, and video cameras. (c) “Low-voltage electric fence” means an alarm system, as defined in s. 489.505, that consists of a fence structure and an energizer powered by a commercial storage battery not exceeding 12 volts which produces an electric charge upon contact with the fence structure. (d) “Wireless alarm system” means a burglar alarm system or smoke detector that is not hardwired. (2) Notwithstanding any provision of this code, this section applies to all low-voltage alarm system projects for which a permit is required by a local enforcement agency. However, a permit is not required to install, maintain, inspect, replace, or service a wireless alarm system, including any ancillary components or equipment attached to the system. (3) A low-voltage electric fence must meet all of the following requirements to be permitted as a low-voltage alarm system project and no further permit shall be required for the low-voltage alarm system project other than as provided in this section: (a) The electric charge produced by the fence upon contact must not exceed energizer characteristics set forth in paragraph 22.108 and depicted in Figure 102 of International Electrotechnical Commission Standard No. 60335-2-76, Current Edition. (b) A nonelectric fence or wall must completely enclose the low-voltage electric fence. The lowvoltage electric fence may be up to 2 feet higher than the perimeter nonelectric fence or wall. (c) The low-voltage electric fence must be identified using warning signs attached to the fence at intervals of not more than 60 feet. (d) The low-voltage electric fence shall not be installed in an area zoned exclusively for singlefamily or multi-family residential use. (e) The low-voltage electric fence shall not enclose the portions of a property which are used for residential purposes. (4) This section does not apply to the installation or replacement of a fire alarm if a plan review is required. FLORIDA BUILDING CODE — BUILDING, 8th EDITION (2023) (5) A local enforcement agency shall make uniform basic permit labels available for purchase by a contractor to be used for the installation or replacement of a new or existing alarm system at a cost as indicated in s. 553.793, Florida Statutes. The local enforcement agency may not require the payment of any additional fees, charges, or expenses associated with the installation or replacement of a new or existing alarm. (a) A local enforcement agency may not require a contractor, as a condition of purchasing a label, to submit information other than identification information of the licensee and proof of registration or certification as a contractor. (b) A label is valid for 1 year after the date of purchase and may only be used within the jurisdiction of the local enforcement agency that issued the label. A contractor may purchase labels in bulk for one or more unspecified current or future projects. (6) A contractor shall post an unused uniform basic permit label in a conspicuous place on the premises of the low-voltage alarm system project site before commencing work on the project. (7) A contractor is not required to notify the local enforcement agency before commencing work on a low-voltage alarm system project. However, a contractor must submit a Uniform Notice of a Low-Voltage Alarm System Project as provided under subsection (7) to the local enforcement agency within 14 days after completing the project. A local enforcement agency may take disciplinary action against a contractor who fails to timely submit a Uniform Notice of a Low-Voltage Alarm System Project. (8) The Uniform Notice of a Low-Voltage Alarm System Project may be submitted electronically or by facsimile if all submissions are signed by the owner, tenant, contractor, or authorized representative of such persons. The Uniform Notice of a Low-Voltage Alarm System Project shall be in the format prescribed by the local enforcement agency and must comply with the requirements of s. 553.793(7), Florida Statutes. (9) A local enforcement agency may coordinate directly with the owner or customer to inspect a low-voltage alarm system to ensure compliance with applicable codes and standards. If a low-voltage alarm system project fails an inspection, the contractor must take corrective action as necessary to pass inspection. (10) A municipality, county, district, or other entity of local government may not adopt or maintain in effect any ordinance or rule regarding a low-voltage alarm system project that is inconsistent with this section. (11) A uniform basic permit label shall not be required for the subsequent maintenance, inspection, or service of an alarm system that was permitted in accordance with this section. The provisions of this act are not intended to impose new or additional licensure requirements on persons 11 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 SCOPE AND ADMINISTRATION licensed in accordance with the applicable provisions of Chapter 489, Florida Statutes. SECTION 106 FLOOR AND ROOF DESIGN LOADS [A] 106.1 Live loads posted. In commercial or industrial buildings, for each floor or portion thereof designed for live loads exceeding 50 psf (2.40 kN/m2), such design live loads shall be conspicuously posted by the owner or the owner’s authorized agent in that part of each story in which they apply, using durable signs. It shall be unlawful to remove or deface such notices. [A] 106.2 Issuance of certificate of occupancy. A certificate of occupancy required by Section 111 shall not be issued until the floor load signs, required by Section 106.1, have been installed. [A] 106.3 Restrictions on loading. It shall be unlawful to place, or cause or permit to be placed, on any floor or roof of a building, structure or portion thereof, a load greater than is permitted by this code. SECTION 107 SUBMITTAL DOCUMENTS [A] 107.1 General. Submittal documents consisting of construction documents, statement of special inspections, geotechnical report and other data shall be submitted in two or more sets with each permit application. The construction documents shall be prepared by a registered design professional where required by Chapter 471, Florida Statutes or Chapter 481, Florida Statutes. Where special conditions exist, the building official is authorized to require additional construction documents to be prepared by a registered design professional. Exception: The building official is authorized to waive the submission of construction documents and other data not required to be prepared by a registered design professional if it is found that the nature of the work applied for is such that review of construction documents is not necessary to obtain compliance with this code. [A] 107.2 Construction documents. Construction documents shall be in accordance with Sections 107.2.1 through 107.2.6. [A] 107.2.1 Information on construction documents. Construction documents shall be dimensioned and drawn upon suitable material. Electronic media documents are permitted to be submitted where approved by the building official. Construction documents shall be of sufficient clarity to indicate the location, nature and extent of the work proposed and show in detail that it will conform to the provisions of this code and relevant laws, ordinances, rules and regulations, as determined by the building official. [A] 107.2.2 Fire protection system shop drawings. Shop drawings for the fire protection system(s) shall be submitted to indicate conformance to this code and the construction documents and shall be approved prior to the start of system installation. Shop drawings shall contain all infor12 mation as required by the referenced installation standards in Chapter 9. [A] 107.2.3 Means of egress. The construction documents shall show in sufficient detail the location, construction, size and character of all portions of the means of egress including the path of the exit discharge to the public way in compliance with the provisions of this code. In other than occupancies in Groups R-2, R-3, and I-1, the construction documents shall designate the number of occupants to be accommodated on every floor, and in all rooms and spaces. [A] 107.2.4 Exterior wall envelope. Construction documents for all buildings shall describe the exterior wall envelope in sufficient detail to determine compliance with this code. The construction documents shall provide details of the exterior wall envelope as required, including flashing, intersections with dissimilar materials, corners, end details, control joints, intersections at roof, eaves or parapets, means of drainage, water-resistive membrane and details around openings. The construction documents shall include manufacturer’s installation instructions that provide supporting documentation that the proposed penetration and opening details described in the construction documents maintain the weather resistance of the exterior wall envelope. The supporting documentation shall fully describe the exterior wall system that was tested, where applicable, as well as the test procedure used. 107.2.5 Exterior balcony and elevated walking surfaces. Where balcony or other elevated walking surfaces are exposed to water from direct or blowing rain or irrigation, and the structural framing is protected by an impervious moisture barrier, the construction documents shall include details for all elements of the impervious moisture barrier system. The construction documents shall include manufacturer's installation instructions. [A] 107.2.6 Site plan. The construction documents submitted with the application for permit shall be accompanied by a site plan showing to scale the size and location of new construction and existing structures on the site, distances from lot lines, the established street grades and the proposed finished grades and, as applicable, flood hazard areas, floodways, and design flood elevations; and it shall be drawn in accordance with an accurate boundary line survey. In the case of demolition, the site plan shall show construction to be demolished and the location and size of existing structures and construction that are to remain on the site or plot. The building official is authorized to waive or modify the requirement for a site plan where the application for permit is for alteration or repair or where otherwise warranted. [A] 107.2.6.1 Design flood elevations. Where design flood elevations are not specified, they shall be established in accordance with Section 1612.3.1. 107.2.6.2 For the purpose of inspection and record retention, site plans for a building may be maintained in the form of an electronic copy at the worksite. These plans must be open to inspection by the building offiFLORIDA BUILDING CODE — BUILDING, 8th EDITION (2023) Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 SCOPE AND ADMINISTRATION cial or a duly authorized representative, as required by the Florida Building Code. [A] 107.2.7 Structural information. The construction documents shall provide the information specified in Section 1603. [A] 107.3 Examination of documents. The building official shall examine or cause to be examined the accompanying submittal documents and shall ascertain by such examinations whether the construction indicated and described is in accordance with the requirements of this code and other pertinent laws or ordinances. Exceptions: 1. Building plans approved pursuant to Section 553.77(5), Florida Statutes, and state-approved manufactured buildings are exempt from local codes enforcing agency plan reviews except for provisions of the code relating to erection, assembly or construction at the site. Erection, assembly and construction at the site are subject to local permitting and inspections. Photocopies of plans approved according to Rule 61-41.009, Florida Administrative Code, shall be sufficient for local permit application documents of record for the modular building portion of the permitted project. 2. Industrial construction on sites where design, construction and fire safety are supervised by appropriate design and inspection professionals and which contain adequate in-house fire departments and rescue squads is exempt, subject to local government option, from review of plans and inspections, providing owners certify that applicable codes and standards have been met and supply appropriate approved drawings to local building and fire-safety inspectors. [A] 107.3.1 Approval of construction documents. When the building official issues a permit, the construction documents shall be approved, in writing or by stamp, as “Reviewed for Code Compliance.” One set of construction documents so reviewed shall be retained by the building official. The other set shall be returned to the applicant, shall be kept at the site of work and shall be open to inspection by the building official or a duly authorized representative. [A] 107.3.2 Previous approvals. This code shall not require changes in the construction documents, construction or designated occupancy of a structure for which a lawful permit has been heretofore issued or otherwise lawfully authorized, and the construction of which has been pursued in good faith within 180 days after the effective date of this code and has not been abandoned. [A] 107.3.3 Phased approval. The building official is authorized to issue a permit for the construction of foundations or any other part of a building or structure before the construction documents for the whole building or structure have been submitted, provided that adequate information and detailed statements have been filed complying with pertinent requirements of this code. The holder of such FLORIDA BUILDING CODE — BUILDING, 8th EDITION (2023) permit for the foundation or other parts of a building or structure shall proceed at the holder’s own risk with the building operation and without assurance that a permit for the entire structure will be granted. [A] 107.3.4 Design professional in responsible charge. Reserved. [A] 107.3.4.1 Deferred submittals. Deferral of any submittal items shall have the prior approval of the building official. The registered design professional in responsible charge shall list the deferred submittals on the construction documents for review by the building official. Documents for deferred submittal items shall be submitted to the registered design professional in responsible charge who shall review them and forward them to the building official with a notation indicating that the deferred submittal documents have been reviewed and found to be in general conformance to the design of the building. The deferred submittal items shall not be installed until the deferred submittal documents have been approved by the building official. 107.3.4.2 Certifications by contractors authorized under the provisions of Section 489.115(4)(b), Florida Statutes, shall be considered equivalent to sealed plans and specifications by a person licensed under Chapter 471, Florida Statutes, or Chapter 481, Florida Statutes, by local enforcement agencies for plans review for permitting purposes relating to compliance with the windresistance provisions of the code or alternate methodologies approved by the Florida Building Commission for one- and two-family dwellings. Local enforcement agencies may rely upon such certification by contractors that the plans and specifications submitted conform to the requirements of the code for wind resistance. Upon good cause shown, local government code enforcement agencies may accept or reject plans sealed by persons licensed under Chapters 471, 481 or 489, Florida Statutes. 107.3.5 Minimum plan review criteria for buildings. The examination of the documents by the building official shall include the following minimum criteria and documents: a floor plan; site plan; foundation plan; floor/roof framing plan or truss layout; all fenestration penetrations; flashing; and rough opening dimensions; and all exterior elevations: Commercial Buildings: Building: 1. Site requirements: Parking Fire access Vehicle loading Driving/turning radius Fire hydrant/water supply/post indicator valve (PIV) Set back/separation (assumed property lines) Location of specific tanks, water lines and sewer lines 13 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 SCOPE AND ADMINISTRATION Roof systems Threshold inspection plan Stair systems Flood hazard areas, flood zones, and design flood elevations 2. Occupancy group and special occupancy requirements shall be determined. 3. Minimum type of construction shall be determined (see Table 504.3a). 4. Fire-resistant construction requirements shall include the following components: 9. Wood Steel Aluminum Concrete Plastic Glass Masonry Gypsum board and plaster Insulating (mechanical) Roofing Insulation Fire-resistant separations Fire-resistant protection for type of construction Protection of openings and penetrations of rated walls Fire blocking and draftstopping and calculated fire resistance 5. Fire suppression systems shall include: 10. Accessibility requirements shall include the following: Early warning smoke evacuation systems Schematic fire sprinklers Standpipes Pre-engineered systems Riser diagram. 6. 7. 11. Interior requirements shall include the following: shall Occupancy load Gross Net Means of egress Exit access Exit Exit discharge Stairs construction/geometry and protection Doors Emergency lighting and exit signs Specific occupancy requirements Construction requirements Horizontal exits/exit passageways 8. 14 Site requirements Accessible route Vertical accessibility Toilet and bathing facilities Drinking fountains Equipment Special occupancy requirements Fair housing requirements Life safety systems shall be determined and shall include the following requirements: Occupant load and egress capacities Early warning Smoke control Stair pressurization Systems schematic Occupancy load/egress requirements include: Structural requirements shall include: Soil conditions/analysis Termite protection Design loads Wind requirements Building envelope Impact resistant coverings or systems Structural calculations (if required) Foundation Flood requirements in accordance with Section 1612, including lowest floor elevations, enclosures, flood damageresistant materials Wall systems Floor systems Materials shall be reviewed and shall at a minimum include the following: Interior finishes (flame spread/smoke development) Light and ventilation Sanitation 12. Special systems: Elevators Escalators Lifts 13. Swimming pools: Barrier requirements Spas Wading pools 14. Location and installation details. The specific location and installation details of each fire door, fire damper, ceiling damper and smoke damper shall be shown and properly identified on the building plans by the designer. Electrical: 1. Electrical: Wiring Services Feeders and branch circuits Overcurrent protection Grounding Wiring methods and materials GFCIs FLORIDA BUILDING CODE — BUILDING, 8th EDITION (2023) Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 SCOPE AND ADMINISTRATION 2. Equipment 3. Combustion air 3. 4. Special occupancies Emergency systems 4. Chimneys and vents 5. Appliances 5. 6. Communication systems Low voltage 6. Type of gas 7. Fireplaces 7. 8. Load calculations Design flood elevation 8. LP tank location Plumbing: 9. Riser diagram/shutoffs 10. Design flood elevation 1. Minimum plumbing facilities 2. Fixture requirements 3. Water supply piping 4. Sanitary drainage 5. Water heaters 6. Vents 7. Roof drainage 2. Fire-resistant construction (if required) 8. Back flow prevention 3. Fire 9. Irrigation 4. Smoke detector locations 5. Egress: Demolition: 1. Asbestos removal Residential (one- and two-family): 1. Site requirements: Set back/separation (assumed property lines) Location of septic tanks 10. Location of water supply line 11. Grease traps Egress window size and location stairs construction requirements 12. Environmental requirements 6. 13. Plumbing riser Wall section from foundation through roof, including assembly and materials connector tables wind requirements structural calculations (if required) Flood hazard areas, flood zones, design flood elevations, lowest floor elevations, enclosures, equipment, and flood damageresistant materials 14. Design flood elevation Mechanical: 1. Energy calculations 2. Exhaust systems: Structural requirements shall include: Clothes dryer exhaust Kitchen equipment exhaust Specialty exhaust systems 7. Accessibility requirements: 3. Equipment 4. Equipment location 5. Make-up air 6. Roof-mounted equipment 7. Duct systems 8. Ventilation Plans examination by the building official shall not be required for the following work: 9. Combustion air 1. Replacing existing equipment such as mechanical units, water heaters, etc. 11. Appliances 2. Reroofs 12. Boilers 3. Minor electrical, plumbing and mechanical repairs 14. Bathroom ventilation 4. Annual maintenance permits 15. Laboratory 5. Prototype plans: Show/identify Accessible bath 8. Exemptions: 10. Chimneys, fireplaces and vents 13. Refrigeration Except for local site adaptions, siding, foundations and/or modifications. Except for structures that require waiver. 16. Design flood elevation Gas: 1. Gas piping 2. Venting 6. FLORIDA BUILDING CODE — BUILDING, 8th EDITION (2023) Impact resistant coverings or systems Manufactured buildings plan except for foundations and modifications of buildings on site. 15 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 SCOPE AND ADMINISTRATION [A] 107.4 Amended construction documents. Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in compliance with the approved construction documents shall be resubmitted for approval as an amended set of construction documents. [A] 107.5 Retention of construction documents. One set of approved construction documents shall be retained by the building official for a period of not less than 180 days from date of completion of the permitted work, or as required by state or local laws. 107.6 Affidavits. The building official may accept a sworn affidavit from a registered architect or engineer stating that the plans submitted conform to the technical codes. For buildings and structures, the affidavit shall state that the plans conform to the laws as to egress, type of construction and general arrangement and, if accompanied by drawings, show the structural design and that the plans and design conform to the requirements of the technical codes as to strength, stresses, strains, loads and stability. The building official may without any examination or inspection accept such affidavit, provided the architect or engineer who made such affidavit agrees to submit to the building official copies of inspection reports as inspections are performed and upon completion of the structure, electrical, gas, mechanical or plumbing systems a certification that the structure, electrical, gas, mechanical or plumbing system has been erected in accordance with the requirements of the technical codes. Where the building official relies upon such affidavit, the architect or engineer shall assume full responsibility for compliance with all provisions of the technical codes and other pertinent laws or ordinances. The building official shall ensure that any person conducting plans review is qualified as a plans examiner under Part XII of Chapter 468, Florida Statutes, and that any person conducting inspections is qualified as a building inspector under Part XII of Chapter 468, Florida Statutes. 107.6.1 Building permits issued in flood hazard areas on the basis of an affidavit. Pursuant to the requirements of federal regulation for participation in the National Flood Insurance Program (44 C.F.R. Parts 59 and 60), the authority granted to the building official to issue permits, to rely on inspections, and to accept plans and construction documents on the basis of affidavits and plans submitted pursuant to Sections 105.14 and 107.6, shall not extend to the flood load and flood-resistance construction requirements of the Florida Building Code. 107.6.2 Affidavits provided pursuant to Section 553.791, Florida Statutes. For a building or structure in a flood hazard area, the building official shall review any affidavit certifying compliance with the flood load and flood-resistant construction requirements of the Florida Building Code. SECTION 108 TEMPORARY STRUCTURES AND USES [A] 108.1 General. The building official is authorized to issue a permit for temporary structures and temporary uses. Such permits shall be limited as to time of service, but shall 16 not be permitted for more than 180 days. The building official is authorized to grant extensions for demonstrated cause. [A] 108.2 Conformance. Temporary structures and uses shall comply with the requirements in Section 3103. [A] 108.3 Temporary power. The building official is authorized to give permission to temporarily supply and use power in part of an electric installation before such installation has been fully completed and the final certificate of completion has been issued. The part covered by the temporary certificate shall comply with the requirements specified for temporary lighting, heat or power in NFPA 70. [A] 108.4 Termination of approval. The building official is authorized to terminate such permit for a temporary structure or use and to order the temporary structure or use to be discontinued. SECTION 109 FEES [A] 109.1 Payment of fees. A permit shall not be valid until the fees prescribed by law have been paid, nor shall an amendment to a permit be released until the additional fee, if any, has been paid. [A] 109.2 Schedule of permit fees. On buildings, structures, electrical, gas, mechanical, and plumbing systems or alterations requiring a permit, a fee for each permit shall be paid as required, in accordance with the schedule as established by the applicable governing authority. [A] 109.3 Building permit valuations. The applicant for a permit shall provide an estimated permit value at time of application. Permit valuations shall include total value of work, including materials and labor, for which the permit is being issued, such as electrical, gas, mechanical, plumbing equipment and permanent systems. If, in the opinion of the building official, the valuation is underestimated on the application, the permit shall be denied, unless the applicant can show detailed estimates to meet the approval of the building official. Final building permit valuation shall be set by the building official. [A] 109.4 Work commencing before permit issuance. Any person who commences any work on a building, structure, electrical, gas, mechanical or plumbing system before obtaining the necessary permits shall be subject to a fee established by the building official that shall be in addition to the required permit fees. [A] 109.5 Related fees. Reserved. [A] 109.6 Refunds. Reserved. SECTION 110 INSPECTIONS [A] 110.1 General. Construction or work for which a permit is required shall be subject to inspection by the building official and such construction or work shall remain exposed and provided with access for inspection purposes until approved. Approval as a result of an inspection shall not be construed to be an approval of a violation of the provisions of this code or FLORIDA BUILDING CODE — BUILDING, 8th EDITION (2023) Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 SCOPE AND ADMINISTRATION of other ordinances of the jurisdiction. Inspections presuming to give authority to violate or cancel the provisions of this code or of other ordinances of the jurisdiction shall not be valid. It shall be the duty of the owner or the owner’s authorized agent to cause the work to remain exposed and provided with access for inspection purposes. Neither the building official nor the jurisdiction shall be liable for expense entailed in the removal or replacement of any material required to allow inspection. [A] 110.2 Preliminary inspection. Before issuing a permit, the building official is authorized to examine or cause to be examined buildings, structures and sites for which an application has been filed. [A] 110.3 Required inspections. The building official upon notification from the permit holder or his or her agent shall make the following inspections, and shall either release that portion of the construction or shall notify the permit holder or his or her agent of any violations which must be corrected in order to comply with the technical codes. The building official shall determine the timing and sequencing of when inspections occur and what elements are inspected at each inspection. Building 1. Foundation inspection. To be made after trenches are excavated and forms erected and shall at a minimum include the following building components: • Stem-wall • Monolithic slab-on-grade • Piling/pile caps • Footers/grade beams 1.1. In flood hazard areas, upon placement of the lowest floor, including basement, and prior to further vertical construction, the elevation certification shall be submitted to the authority having jurisdiction. 2. Framing inspection. To be made after the roof, all framing, fireblocking and bracing is in place, all concealing wiring, all pipes, chimneys, ducts and vents are complete and shall at a minimum include the following building components: • Window/door framing • Vertical cells/columns • Lintel/tie beams • Framing/trusses/bracing/connectors • Draft stopping/fire blocking • Curtain wall framing • Energy insulation • Accessibility • Verify rough opening dimensions are within tolerances. 3. Sheathing inspection. To be made either as part of a dry-in inspection or done separately at the request FLORIDA BUILDING CODE — BUILDING, 8th EDITION (2023) of the contractor after all roof and wall sheathing and fasteners are complete and shall at a minimum include the following building components: • Roof sheathing • Wall sheathing • Sheathing fasteners • Roof/wall dry-in 4. Exterior wall coverings. Shall at a minimum include the following building components in progress inspections: • Exterior wall coverings and veneers • Soffit coverings 5. Roofing inspection. Shall at a minimum include the following building components: • Dry-in • Insulation • Roof coverings • Flashing 6. Final inspection. To be made after the building is completed and ready for occupancy. 6.1. In flood hazard areas, as part of the final inspection, a final certification of the lowest floor elevation or the elevation to which a building is dry floodproofed, as applicable, shall be submitted to the authority having jurisdiction. 7. Swimming pool inspection. First inspection to be made after excavation and installation of reinforcing steel, bonding and main drain and prior to placing of concrete. Final inspection to be made when the swimming pool is complete and all required enclosure requirements are in place. In order to pass final inspection and receive a certificate of completion, a residential swimming pool must meet the requirements relating to pool safety features as described in Section 454.2.17 of this code. 8. Demolition inspections. First inspection to be made after all utility connections have been disconnected and secured in such manner that no unsafe or unsanitary conditions shall exist during or after demolition operations. Final inspection to be made after all demolition work is completed. 9. Manufactured building inspections. The building department shall inspect construction of foundations; connecting buildings to foundations; installation of parts identified on plans as site installed items, joining the modules, including utility crossovers; utility connections from the building to utility lines on site; and any other work done on site which requires compliance with the Florida Build17 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 SCOPE AND ADMINISTRATION ing Code. Additional inspections may be required for public educational facilities (see Section 453.27.20 of this code). 10. Where impact-resistant coverings or impact-resistant systems are installed, the building official shall schedule adequate inspections of impactresistant coverings or impact-resistant systems to determine the following: The system indicated on the plans was installed. The system is installed in accordance with the manufacturer’s installation instructions and the product approval. Electrical 1. Underground inspection. To be made after trenches or ditches are excavated, conduit or cable installed, and before any backfill is put in place. 2. Rough-in inspection. To be made after the roof, framing, fireblocking and bracing is in place and prior to the installation of wall or ceiling membranes. Gas 1. Rough piping inspection. To be made after all new piping authorized by the permit has been installed, and before any such piping has been covered or concealed or any fixtures or gas appliances have been connected. 2. Final piping inspection. To be made after all piping authorized by the permit has been installed and after all portions which are to be concealed by plastering or otherwise have been so concealed, and before any fixtures or gas appliances have been connected. This inspection shall include a pressure test. 3. Final inspection. To be made on all new gas work authorized by the permit and such portions of existing systems as may be affected by new work or any changes, to ensure compliance with all the requirements of this code and to assure that the installation and construction of the gas system is in accordance with reviewed plans. 3. Final inspection. To be made after the building is complete, all required electrical fixtures are in place and properly connected or protected, and the structure is ready for occupancy. [A] 110.3.1 Footing and foundation inspection. Reserved. 4. Existing Swimming Pools. To be made after all repairs or alterations are complete, all required electrical equipment, GFCI protection, and equipotential bonding are in place on said alterations or repairs. [A] 110.3.3 Lowest floor elevation. Reserved. Plumbing 1. Underground inspection. To be made after trenches or ditches are excavated, piping installed, and before any backfill is put in place. 2. Rough-in inspection. To be made after the roof, framing, fireblocking and bracing is in place and all soil, waste and vent piping is complete, and prior to this installation of wall or ceiling membranes. 3. Final inspection. To be made after the building is complete, all plumbing fixtures are in place and properly connected, and the structure is ready for occupancy. Note: See Section 312 of the Florida Building Code, Plumbing for required tests. Mechanical 1. Underground inspection. To be made after trenches or ditches are excavated, underground duct and fuel piping installed, and before any backfill is put in place. 2. Rough-in inspection. To be made after the roof, framing, fire blocking and bracing are in place and all ducting, and other concealed components are complete, and prior to the installation of wall or ceiling membranes. 18 3. Final inspection. To be made after the building is complete, the mechanical system is in place and properly connected, and the structure is ready for occupancy. [A] 110.3.2 Concrete slab and under-floor inspection. Reserved. [A] 110.3.4 Frame inspection. Reserved. [A] 110.3.5 Lath, gypsum board and gypsum panel product inspection. Lath, gypsum board and gypsum panel product inspections shall be made after lathing, gypsum board and gypsum panel products, interior and exterior, are in place, but before any plastering is applied or gypsum board and gypsum panel product joints and fasteners are taped and finished. Exception: Gypsum board and gypsum panel products that are not part of a fire-resistance-rated assembly or a shear assembly. 110.3.6 Weather-exposed balcony and walking surface waterproofing. Where balcony or other elevated walking surfaces are exposed to water from direct or blowing rain or irrigation, and the structural framing is protected by an impervious moisture barrier, all elements of the impervious-moisture-barrier system shall not be concealed until inspected and approved. [A] 110.3.7 Fire- and smoke-resistant penetrations. Protection of joints and penetrations in fire-resistancerated assemblies, smoke barriers and smoke partitions shall not be concealed from view until inspected and approved. [A] 110.3.8 Energy efficiency inspections. Inspections shall be made to determine compliance with Chapter 13 and shall include, but not be limited to, inspections for: envelope insulation R- and U-values, fenestration U-value, FLORIDA BUILDING CODE — BUILDING, 8th EDITION (2023) Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 SCOPE AND ADMINISTRATION duct system R-value, and HVAC and water-heating equipment efficiency. [A] 110.3.9 Other inspections. In addition to the inspections specified in Sections 110.3 through 110.3.8, the building official is authorized to make or require other inspections of any construction work to ascertain compliance with the provisions of this code and other laws that are enforced by the department of building safety. [A] 110.3.10 Special inspections. Reserved. [A] 110.3.11 Final inspection. Reserved. [A] 110.3.11.1 Flood hazard documentation. Reserved. 110.3.12 Termites. Building components and building surroundings required to be protected from termite damage in accordance with Section 1503.7, Section 2304.12.6 or Section 2304.12.2.8, specifically required to be inspected for termites in accordance with Section 2114, or required to have chemical soil treatment in accordance with Section 1816 shall not be covered or concealed until the release from the building official has been received. 110.3.13 Impact-resistant coverings or systems. Where impact-resistant coverings or systems are installed to meet requirements of this code, the building official shall schedule adequate inspections of impact-resistant coverings or systems to determine the following: 1. The system indicated on the plans was installed. 2. The system is installed in accordance with the manufacturer’s installation instructions and the product approval. [A] 110.4 Inspection agencies. Reserved. [A] 110.5 Inspection requests. It shall be the duty of the holder of the building permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspections of such work that are required by this code. [A] 110.6 Approval required. Work shall not be done beyond the point indicated in each successive inspection without first obtaining the approval of the building official. The building official, upon notification, shall make the requested inspections and shall either indicate the portion of the construction that is satisfactory as completed, or notify the permit holder or his or her agent wherein the same fails to comply with this code. Any portions that do not comply shall be corrected and such portion shall not be covered or concealed until authorized by the building official. 110.7 Shoring. For threshold buildings, shoring and associated formwork or falsework shall be designed and inspected by a Florida licensed professional engineer prior to any required mandatory inspections by the threshold building inspector. 110.8 Threshold building. 110.8.1 During new construction or during repair or restoration projects in which the structural system or structural loading of a building is being modified, the enforcing FLORIDA BUILDING CODE — BUILDING, 8th EDITION (2023) agency shall require a special inspector to perform structural inspections on a threshold building pursuant to a structural inspection plan prepared by the engineer or architect of record. The structural inspection plan must be submitted to the enforcing agency prior to the issuance of a building permit for the construction of a threshold building. The purpose of the structural inspection plans is to provide specific inspection procedures and schedules so that the building can be adequately inspected for compliance with the permitted documents. The special inspector may not serve as a surrogate in carrying out the responsibilities of the building official, the architect, or the engineer of record. The contractor’s contractual or statutory obligations are not relieved by any action of the special inspector. 110.8.2 The special inspector shall determine that a professional engineer who specializes in shoring design has inspected the shoring and reshoring for conformance with the shoring and reshoring plans submitted to the enforcing agency. A fee simple title owner of a building, which does not meet the minimum size, height, occupancy, occupancy classification, or number-of-stories criteria which would result in classification as a threshold building under s. 553.71(7), Florida Statutes may designate such building as a threshold building, subject to more than the minimum number of inspections required by the Florida Building Code. 110.8.3 The fee owner of a threshold building shall select and pay all costs of employing a special inspector, but the special inspector shall be responsible to the enforcement agency. The inspector shall be a person certified, licensed or registered under Chapter 471, Florida Statutes, as an engineer or under Chapter 481, Florida Statutes, as an architect. 110.8.4 Each enforcement agency shall require that, on every threshold building: 110.8.4.1 The special inspector, upon completion of the building and prior to the issuance of a certificate of occupancy, file a signed and sealed statement with the enforcement agency in substantially the following form: “To the best of my knowledge and belief, the above described construction of all structural loadbearing components complies with the permitted documents, and the shoring and reshoring conforms to the shoring and reshoring plans submitted to the enforcement agency.” 110.8.4.2 Any proposal to install an alternate structural product or system to which building codes apply be submitted to the enforcement agency for review for compliance with the codes and made part of the enforcement agency’s recorded set of permit documents. 110.8.4.3 All shoring and reshoring procedures, plans and details be submitted to the enforcement agency for recordkeeping. Each shoring and reshoring installation shall be supervised, inspected and certified to be in compliance with the shoring documents by the contractor. 19 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 SCOPE AND ADMINISTRATION 110.8.4.4 All plans for the building which are required to be signed and sealed by the architect or engineer of record contain a statement that, to the best of the architect’s or engineer’s knowledge, the plans and specifications comply with the applicable minimum building codes and the applicable fire-safety standards as determined by the local authority in accordance with this section and Chapter 633, Florida Statutes. 110.8.5 No enforcing agency may issue a building permit for construction of any threshold building except to a licensed general contractor, as defined in Section 489.105(3)(a), Florida Statutes, or to a licensed building contractor, as defined in Section 489.105(3)(b), Florida Statutes, within the scope of her or his license. The named contractor to whom the building permit is issued shall have the responsibility for supervision, direction, management and control of the construction activities on the project for which the building permit was issued. 110.8.6 The building department may allow a special inspector to conduct the minimum structural inspection of threshold buildings required by this code, Section 553.73, Florida Statutes, without duplicative inspection by the building department. The building official is responsible for ensuring that any person conducting inspections is qualified as a building inspector under Part XII of Chapter 468, Florida Statutes, or certified as a special inspector under Chapter 471 or 481, Florida Statutes. Inspections of threshold buildings required by Section 553.79(5), Florida Statutes, are in addition to the minimum inspections required by this code. 110.9 Mandatory structural inspections for condominium and cooperative buildings. 110.9.1 General. The Legislature finds that maintaining the structural integrity of a building throughout its service life is of paramount importance in order to ensure that buildings are structurally sound so as to not pose a threat to the public health, safety, or welfare. As such, the Legislature finds that the imposition of a statewide structural inspection program for aging condominium and cooperative buildings in this state is necessary to ensure that such buildings are safe for continued use. 110.9.2 As used in this section, the terms: (a) “Milestone inspection” means a structural inspection of a building, including an inspection of load-bearing walls and the primary structural members and primary structural systems as those terms are defined in s. 627.706, Florida Statutes, by a licensed architect or engineer authorized to practice in this state for the purposes of attesting to the life safety and adequacy of the structural components of the building and, to the extent reasonably possible, determining the general structural condition of the building as it affects the safety of such building, including a determination of any necessary maintenance, repair, or replacement of any structural component of the building. The purpose of such inspection is not to determine if the condition of an existing building is in compliance with the Florida Building Code or the fire safety code. 20 (b) “Substantial structural deterioration” means substantial structural distress that negatively affects a building’s general structural condition and integrity. The term does not include surface imperfections such as cracks, distortion, sagging, deflections, misalignment, signs of leakage, or peeling of finishes unless the licensed engineer or architect performing the phase one or phase two inspection determines that such surface imperfections are a sign of substantial structural deterioration. 110.9.3 A condominium association under Chapter 718, Florida Statutes, and a cooperative association under Chapter 719, Florida Statutes, must have a milestone inspection performed for each building that is three stories or more in height by December 31 of the year in which the building reaches 30 years of age, based on the date the certificate of occupancy for the building was issued, and every 10 years thereafter. If the building is located within 3 miles of a coastline as defined in s. 376.031, Florida Statutes, the condominium association or cooperative association must have a milestone inspection performed by December 31 of the year in which the building reaches 25 years of age, based on the date the certificate of occupancy for the building was issued, and every 10 years thereafter. The condominium association or cooperative association must arrange for the milestone inspection to be performed and is responsible for ensuring compliance with the requirements of this section. The condominium association or cooperative association is responsible for all costs associated with the inspection. This subsection does not apply to a single- family, two-family, or three-family dwelling with three or fewer habitable stories above ground. 110.9.4 If a milestone inspection is required under this section and the building’s certificate of occupancy was issued on or before July 1, 1992, the building’s initial milestone inspection must be performed before December 31, 2024. If the date of issuance for the certificate of occupancy is not available, the date of issuance of the building’s certificate of occupancy shall be the date of occupancy evidenced in any record of the local building official. 110.9.5 Upon determining that a building must have a milestone inspection, the local enforcement agency must provide written notice of such required inspection to the condominium association or cooperative association by certified mail, return receipt requested. 110.9.6 Within 180 days after receiving the written notice under Section 110.9.5, the condominium association or cooperative association must complete phase one of the milestone inspection. For purposes of this section, completion of phase one of the milestone inspection means the licensed engineer or architect who performed the phase one inspection submitted the inspection report by e-mail, United States Postal Service, or commercial delivery service to the local enforcement agency. 110.9.7 A milestone inspection consists of two phases: 110.9.7.1 For phase one of the milestone inspection, a licensed architect or engineer authorized to practice in FLORIDA BUILDING CODE — BUILDING, 8th EDITION (2023) Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 SCOPE AND ADMINISTRATION this state shall perform a visual examination of habitable and nonhabitable areas of a building, including the major structural components of a building, and provide a qualitative assessment of the structural conditions of the building. If the architect or engineer finds no signs of substantial structural deterioration to any building components under visual examination, phase two of the inspection, as provided in Section 110.9.7.2, is not required. An architect or engineer who completes a phase one milestone inspection shall prepare and submit an inspection report pursuant to Section 110.9.8. 110.9.7.2 A phase two of the milestone inspection must be performed if any substantial structural deterioration is identified during phase one. A phase two inspection may involve destructive or nondestructive testing at the inspector’s direction. The inspection may be as extensive or as limited as necessary to fully assess areas of structural distress in order to confirm that the building is structurally sound and safe for its intended use and to recommend a program for fully assessing and repairing distressed and damaged portions of the building. When determining testing locations, the inspector must give preference to locations that are the least disruptive and most easily repairable while still being representative of the structure. An inspector who completes a phase two milestone inspection shall prepare and submit an inspection report pursuant to Section 110.9.8. 110.9.8 Upon completion of a phase one or phase two milestone inspection, the architect or engineer who performed the inspection must submit a sealed copy of the inspection report with a separate summary of, at minimum, the material findings and recommendations in the inspection report to the condominium association or cooperative association, and to the building official of the local government which has jurisdiction. The inspection report must, at a minimum, meet all of the following criteria: (a) Bear the seal and signature, or the electronic signature, of the licensed engineer or architect who performed the inspection. (b) Indicate the manner and type of inspection forming the basis for the inspection report. (c) Identify any substantial structural deterioration, within a reasonable professional probability based on the scope of the inspection, describe the extent of such deterioration, and identify any recommended repairs for such deterioration. (d) State whether unsafe or dangerous conditions, as those terms are defined in the Florida Building Code, were observed. (e) Recommend any remedial or preventive repair for any items that are damaged but are not substantial structural deterioration. (f) Identify and describe any items requiring further inspection. 110.9.9 The association must distribute a copy of the inspector-prepared summary of the inspection report to each condominium unit owner or cooperative unit owner, FLORIDA BUILDING CODE — BUILDING, 8th EDITION (2023) regardless of the findings or recommendations in the report, by United States mail or personal delivery and by electronic transmission to unit owners who previously consented to received notice by electronic transmission; must post a copy of the inspector-prepared summary in a conspicuous place on the condominium or cooperative property; and must publish the full report and inspectorprepared summary on the association’s website, if the association is required to have a website. 110.9.10 A local enforcement agency may prescribe timelines and penalties with respect to compliance with this section. 110.9.11 A board of county commissioners may adopt an ordinance requiring that a condominium or cooperative association schedule or commence repairs for substantial structural deterioration within a specified timeframe after the local enforcement agency receives a phase two inspection report; however, such repairs must be commenced within 365 days after receiving such report. If an association fails to submit proof to the local enforcement agency that repairs have been scheduled or have commenced for substantial structural deterioration identified in a phase two inspection report within the required timeframe, the local enforcement agency must review and determine if the building is unsafe for human occupancy. SECTION 111 CERTIFICATE OF OCCUPANCY [A] 111.1 Use and occupancy. A building or structure shall not be used or occupied, and a change in the existing use or occupancy classification of a building or structure or portion thereof shall not be made, until the building official has issued a certificate of occupancy therefor as provided herein. Issuance of a certificate of occupancy shall not be construed as an approval of a violation of the provisions of this code or of other ordinances of the jurisdiction. Exception: Certificates of occupancy are not required for work exempt from permits in accordance with Section 105.2. [A] 111.2 Certificate issued. After the building official inspects the building or structure and does not find violations of the provisions of this code or other laws that are enforced by the department of building safety, the building official shall issue a certificate of occupancy that contains the following: 1. The building permit number. 2. The address of the structure. 3. The name and address of the owner or the owner’s authorized agent. 4. A description of that portion of the structure for which the certificate is issued. 5. A statement that the described portion of the structure has been inspected for compliance with the requirements of this code for the occupancy and division of occupancy and the use for which the proposed occupancy is classified. 21 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 SCOPE AND ADMINISTRATION 6. For buildings and structures in flood hazard areas, a statement that documentation of the as-built lowest floor elevation has been provided and is retained in the records of the authority having jurisdiction 7. The name of the building official. 8. The edition of the code under which the permit was issued. 9. The use and occupancy, in accordance with the provisions of Chapter 3. the owner and occupant of the building, structure or service system of the decision to disconnect prior to taking such action. If not notified prior to disconnecting, the owner or occupant of the building, structure or service system shall be notified in writing, as soon as practical thereafter. SECTION 113 BOARD OF APPEALS RESERVED 10. The type of construction as defined in Chapter 6. 11. The design occupant load. 12. If an automatic sprinkler system is provided, whether the sprinkler system is required. SECTION 114 VIOLATIONS RESERVED 13. Any special stipulations and conditions of the building permit. [A] 111.3 Temporary occupancy. The building official is authorized to issue a temporary certificate of occupancy before the completion of the entire work covered by the permit, provided that such portion or portions shall be occupied safely. The building official shall set a time period during which the temporary certificate of occupancy is valid. SECTION 115 STOP WORK ORDER [A] 115.1 Authority. Where the building official finds any work regulated by this code being performed in a manner either contrary to the provisions of this code or dangerous or unsafe, the building official is authorized to issue a stop work order. [A] 111.4 Revocation. The building official is authorized to, in writing, suspend or revoke a certificate of occupancy or completion issued under the provisions of this code wherever the certificate is issued in error, or on the basis of incorrect information supplied, or where it is determined that the building or structure or portion thereof is in violation of any ordinance or regulation or any of the provisions of this code. [A] 115.2 Issuance. The stop work order shall be in writing and shall be given to the owner of the property involved, the owner’s authorized agent or the person performing the work. Upon issuance of a stop work order, the cited work shall immediately cease. The stop work order shall state the reason for the order and the conditions under which the cited work will be permitted to resume. 111.5 Certificate of completion. A certificate of completion is proof that a structure or system is complete and for certain types of permits is released for use and may be connected to a utility system. This certificate does not grant authority to occupy a building, such as shell building, prior to the issuance of a certificate of occupancy. [A] 115.3 Unlawful continuance. Any person who shall continue any work after having been served with a stop work order, except such work as that person is directed to perform to remove a violation or unsafe condition, shall be subject to penalties as prescribed by law. SECTION 112 SERVICE UTILITIES [A] 112.1 Connection of service utilities. A person shall not make connections from a utility, source of energy, fuel or power to any building or system that is regulated by this code for which a permit is required, until released by the building official. [A] 112.2 Temporary connection. The building official shall have the authority to authorize the temporary connection of the building or system to the utility, source of energy, fuel or power. [A] 112.3 Authority to disconnect service utilities. The building official shall have the authority to authorize disconnection of utility service to the building, structure or system regulated by this code and the referenced codes and standards set forth in Section 101.4 in case of emergency where necessary to eliminate an immediate hazard to life or property or where such utility connection has been made without the approval required by Section 112.1 or 112.2. The building official shall notify the serving utility, and wherever possible 22 SECTION 116 UNSAFE STRUCTURES AND EQUIPMENT RESERVED SECTION 117 VARIANCES IN FLOOD HAZARD AREAS 117.1 Flood hazard areas. Pursuant to Section 553.73(5), Florida Statutes, the variance procedures adopted in the local flood plain management ordinance shall apply to requests submitted to the building official for variances to the provisions of Section 1612.4 of the Florida Building Code, Building or, as applicable, the provisions of Section R322 of the Florida Building Code, Residential. This section shall not apply to Section 3109 of the Florida Building Code, Building. FLORIDA BUILDING CODE — BUILDING, 8th EDITION (2023) Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 CHAPTER 2 DEFINITIONS SECTION 201 GENERAL 201.1 Scope. Unless otherwise expressly stated, the following words and terms shall, for the purposes of this code, have the meanings shown in this chapter. 201.2 Interchangeability. Words used in the present tense include the future; words stated in the masculine gender include the feminine and neuter; the singular number includes the plural and the plural, the singular. 201.3 Terms defined in other codes. Where terms are not defined in this code and are defined in the Florida Building Code, Energy Conservation; Florida Building Code, Fuel Gas; Florida Fire Prevention Code; Florida Building Code, Mechanical or Florida Building Code, Plumbing, such terms shall have the meanings ascribed to them as in those codes. 201.4 Terms not defined. Where terms are not defined through the methods authorized by this section, such terms shall have ordinarily accepted meanings such as the context implies. SECTION 202 DEFINITIONS 24-HOUR BASIS. The actual time that a person is an occupant within a facility for the purpose of receiving care. It shall not include a facility that is open for 24 hours and is capable of providing care to someone visiting the facility during any segment of the 24 hours. [BS] AAC MASONRY. Masonry made of autoclaved aerated concrete (AAC) units, manufactured without internal reinforcement and bonded together using thin- or thick-bed mortar. ACCESSIBLE. See the Florida Building Code, Accessibility. ACCESSIBLE MEANS OF EGRESS. A continuous and unobstructed way of egress travel from any accessible point in a building or facility to a public way. ACCESSIBLE ROUTE. See the Florida Building Code, Accessibility. ACCESSIBLE UNIT. See the Florida Building Code, Accessibility. ACCESSORY COMPONENTS. Components used in the installation of pedestals and pedestrian deck panels or pavers of the exterior elevated flooring system. Accessory components are made of either plastic, metal or other approved materials. Accessory components may be used to provide lateral bracing of the pedestals, to provide vertical support, for leveling the pedestal, to restrain the pedestrian deck panels or pavers to the top of the pedestal, or for other system requirements. FLORIDA BUILDING CODE — BUILDING, 8th EDITION (2023) ACCESSORY STRUCTURE. A structure that is accessory to and incidental to that of a building or dwelling(s) and that is located on the same lot. ACCREDITATION BODY. An approved, third-party organization that is independent of the grading and inspection agencies, and the lumber mills, and that initially accredits and subsequently monitors, on a continuing basis, the competency and performance of a grading or inspection agency related to carrying out specific tasks. [A] ADDITION. An extension or increase in floor area, number of stories or height of a building or structure. [BS] ADHERED MASONRY VENEER. Veneer secured and supported through the adhesion of an approved bonding material applied to an approved backing. [BS] ADOBE CONSTRUCTION. Construction in which the exterior load-bearing and nonload-bearing walls and partitions are of unfired clay masonry units, and floors, roofs and interior framing are wholly or partly of wood or other approved materials. Adobe, stabilized. Unfired clay masonry units to which admixtures, such as emulsified asphalt, are added during the manufacturing process to limit the units’ water absorption so as to increase their durability. Adobe, unstabilized. Unfired clay masonry units that do not meet the definition of “Adobe, stabilized.” [F] AEROSOL CONTAINER. A metal can or a glass or plastic bottle designed to dispense an aerosol. [F] AEROSOL PRODUCT. A product that is dispensed from an aerosol container by a propellant. Aerosol products shall be classified by means of the calculation of their chemical heats of combustion and shall be designated Level 1, Level 2 or Level 3. Level 1 aerosol products. Those with a total chemical heat of combustion that is less than or equal to 8,600 British thermal units per pound (Btu/lb) (20 kJ/g). Level 2 aerosol products. Those with a total chemical heat of combustion that is greater than 8,600 Btu/lb (20 kJ/ g), but less than or equal to 13,000 Btu/lb (30 kJ/g). Level 3 aerosol products. Those with a total chemical heat of combustion that is greater than 13,000 Btu/lb (30 kJ/g). [BS] AGGREGATE. In roofing, crushed stone, crushed slag or water-worn gravel used for surfacing for roof coverings. AGRICULTURAL BUILDING. Reserved. AIR-IMPERMEABLE INSULATION. An insulation having an air permeance equal to or less than 0.02 l/s × m2 at 75 pa pressure differential tested in accordance with ASTM E2178 or ASTM E283. 23 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 DEFINITIONS AIR-INFLATED STRUCTURE. A structure that uses airpressurized membrane beams, arches or other elements to enclose space. Occupants of such a structure do not occupy the pressurized area used to support the structure. AIR-SUPPORTED STRUCTURE. A structure wherein the shape of the structure is attained by air pressure and occupants of the structure are within the elevated pressure area. Air-supported structures are of two basic types: Double skin. Similar to a single skin, but with an attached liner that is separated from the outer skin and provides an airspace which serves for insulation, acoustic, aesthetic or similar purposes. Single skin. Where there is only the single outer skin and the air pressure is directly against that skin. AISLE. An unenclosed exit access component that defines and provides a path of egress travel. AISLE ACCESSWAY. That portion of an exit access that leads to an aisle. [F] ALARM NOTIFICATION APPLIANCE. A fire alarm system component such as a bell, horn, speaker, light or text display that provides audible, tactile or visible outputs, or any combination thereof. [F] ALARM SIGNAL. A signal indicating an emergency requiring immediate action, such as a signal indicative of fire. ANNULAR SPACE. The opening around the penetrating item. [F] ANNUNCIATOR. A unit containing one or more indicator lamps, alphanumeric displays or other equivalent means in which each indication provides status information about a circuit, condition or location. APPLICABLE GOVERNING BODY. A city, county, state, state agency or other political government subdivision or entity authorized to administer and enforce the provisions of this code, as adopted or amended. Also applies to administrative authority. [A] APPROVED. Acceptable to the building official. [A] APPROVED AGENCY. An established and recognized agency that is regularly engaged in conducting tests or furnishing inspection services, where such agency has been approved by the building official. [BS] APPROVED FABRICATOR. An established and qualified person, firm or corporation approved by the building official pursuant to Chapter 17 of this code. [A] APPROVED SOURCE. An independent person, firm or corporation, approved by the building official, who is competent and experienced in the application of engineering principles to materials, methods or systems analyses. ARCHITECT. A Florida-registered architect. [F] ALARM VERIFICATION FEATURE. A feature of automatic fire detection and alarm systems to reduce unwanted alarms wherein smoke detectors report alarm conditions for a minimum period of time, or confirm alarm conditions within a given time period, after being automatically reset, in order to be accepted as a valid alarm-initiation signal. [BS] AREA (for masonry). ALLOWABLE STRESS DESIGN. A method of proportioning structural members, such that elastically computed stresses produced in the members by nominal loads do not exceed specified allowable stresses (also called “working stress design”). AREA, BUILDING. The area included within surrounding exterior walls (or exterior walls and fire walls) exclusive of vent shafts and courts. Areas of the building not provided with surrounding walls shall be included in the building area if such areas are included within the horizontal projection of the roof or floor above. [A] ALTERATION. Any construction or renovation to an existing structure other than repair or addition. ALTERNATING TREAD DEVICE. A device that has a series of steps between 50 and 70 degrees (0.87 and 1.22 rad) from horizontal, usually attached to a center support rail in an alternating manner so that the user does not have both feet on the same level at the same time. AMBULATORY CARE FACILITY. Buildings or portions thereof used to provide medical, surgical, psychiatric, nursing or similar care on a less than 24-hour basis to persons who are rendered incapable of self-preservation by the services provided. ANCHOR BUILDING. An exterior perimeter building of a group other than H having direct access to a covered or open mall building but having required means of egress independent of the mall. [BS] ANCHORED MASONRY VENEER. Veneer secured with approved mechanical fasteners to an approved backing. 24 Gross cross-sectional. The area delineated by the out-toout specified dimensions of masonry in the plane under consideration. Net cross-sectional. The area of masonry units, grout and mortar crossed by the plane under consideration based on out-to-out specified dimensions. AREA OF REFUGE. An area where persons unable to use stairways can remain temporarily to await instructions or assistance during emergency evacuation. AREA OF SPORT ACTIVITY. That portion of an indoor or outdoor space where the play or practice of a sport occurs. AREAWAY. A subsurface space adjacent to a building open at the top or protected at the top by a grating or guard. ASSEMBLY SEATING, MULTILEVEL. See “Multilevel assembly seating.” ATRIUM. A vertical space that is closed at the top connecting two or more stories in Group I-2 and I-3 Occupancies or three stories in all other occupancies. ATTIC. The space between the ceiling beams of the top story and the roof rafters. [F] AUDIBLE ALARM NOTIFICATION APPLIANCE. A notification appliance that alerts by the sense of hearing. FLORIDA BUILDING CODE — BUILDING, 8th EDITION (2023) Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 DEFINITIONS [F] AUTOMATIC. As applied to fire protection devices, a device or system providing an emergency function without the necessity for human intervention and activated as a result of a predetermined temperature rise, rate of temperature rise or combustion products. [F] AUTOMATIC FIRE-EXTINGUISHING SYSTEM. An approved system of devices and equipment which automatically detects a fire and discharges an approved fire-extinguishing agent onto or in the area of a fire. AUTOMATIC FLUSH BOLT. Door-locking hardware, installed on the inactive leaf of a pair of doors, which has a bolt that is extended automatically into the door frame or floor when the active leaf is closed after the inactive leaf, and which holds the inactive leaf in a closed position. When the active leaf is opened, the automatic flush bolt retracts the bolt or rod allowing the inactive leaf to be opened (see CONSTANT LATCHING BOLT, DEAD BOLT, MANUAL BOLT). [F] AUTOMATIC SMOKE DETECTION SYSTEM. A fire alarm system that has initiation devices that utilize smoke detectors for protection of an area such as a room or space with detectors to provide early warning of fire. [F] AUTOMATIC SPRINKLER SYSTEM. An automatic sprinkler system, for fire protection purposes, is an integrated system of underground and overhead piping designed in accordance with fire protection engineering standards. The system includes a suitable water supply. The portion of the system above the ground is a network of specially sized or hydraulically designed piping installed in a structure or area, generally overhead, and to which automatic sprinklers are connected in a systematic pattern. The system is usually activated by heat from a fire and discharges water over the fire area. [F] AUTOMATIC WATER MIST SYSTEM. A system consisting of a water supply, a pressure source, and a distribution piping system with attached nozzles, which, at or above a minimum operating pressure, defined by its listing, discharges water in fine droplets meeting the requirements of NFPA 750 for the purpose of the control, suppression or extinguishment of a fire. Such systems include wet-pipe, drypipe and preaction types. The systems are designed as engineered, preengineered, local-application or total-flooding systems. [F] AVERAGE AMBIENT SOUND LEVEL. The root mean square, A-weighted sound pressure level measured over a 24-hour period, or the time any person is present, whichever time period is less. AWNING. An architectural projection that provides weather protection, identity or decoration and is partially or wholly supported by the building to which it is attached. An awning is comprised of a lightweight frame structure over which a covering is attached. An awning may be fixed or moveable, cantilevered, or otherwise entirely supported from a building. BACKING. The wall or surface to which the veneer is secured. FLORIDA BUILDING CODE — BUILDING, 8th EDITION (2023) BALANCED DOOR. A door equipped with double-pivoted hardware so designed as to cause a semicounterbalanced swing action when opening. [F] BALED COTTON. A natural seed fiber wrapped in and secured with industry accepted materials, usually consisting of burlap, woven polypropylene, polyethylene or cotton or sheet polyethylene, and secured with steel, synthetic or wire bands or wire; also includes linters (lint removed from the cottonseed) and motes (residual materials from the ginning process). [F] BALED COTTON, DENSELY PACKED. Cotton made into banded bales with a packing density of not less than 22 pounds per cubic foot (360 kg/m3), and dimensions complying with the following: a length of 55 inches (1397 mm), a width of 21 inches (533.4 mm) and a height of 27.6 to 35.4 inches (701 to 899 mm). [BS] BALLAST. In roofing, ballast comes in the form of large stones or paver systems or light-weight interlocking paver systems and is used to provide uplift resistance for roofing systems that are not adhered or mechanically attached to the roof deck. [F] BARRICADE. A structure that consists of a combination of walls, floor and roof, which is designed to withstand the rapid release of energy in an explosion and which is fully confined, partially vented or fully vented; or other effective method of shielding from explosive materials by a natural or artificial barrier. Artificial barricade. An artificial mound or revetment a minimum thickness of 3 feet (914 mm). Natural barricade. Natural features of the ground, such as hills, or timber of sufficient density that the surrounding exposures that require protection cannot be seen from the magazine or building containing explosives when the trees are bare of leaves. [BS] BASE FLOOD. The flood having a 1-percent chance of being equaled or exceeded in any given year. [BS] BASE FLOOD ELEVATION. The elevation of the base flood, including wave height, relative to the National Geodetic Vertical Datum (NGVD), North American Vertical Datum (NAVD) or other datum specified on the Flood Insurance Rate Map (FIRM). [BS] BASEMENT (for flood loads). The portion of a building having its floor subgrade (below ground level) on all sides. This definition of “Basement” is limited in application to the provisions of Section 1612. BASEMENT. A story that is not a story above grade plane (see “Story above grade plane”). This definition of “Basement” does not apply to the provisions of Section 1612 for flood loads. BEARING WALL STRUCTURE. A building or other structure in which vertical loads from floors and roofs are primarily supported by walls. [BS] BED JOINT. The horizontal layer of mortar on which a masonry unit is laid. 25 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 DEFINITIONS BLEACHERS. Tiered seating supported on a dedicated structural system and two or more rows high and is not a building element (see “Grandstand”). [A] BUILDING OFFICIAL. The officer or other designated authority charged with the administration and enforcement of this code, or a duly authorized representative. BOARDING HOUSE. A building arranged or used for lodging for compensation, with or without meals, and not occupied as a single-family unit. [BS] BUILT-UP ROOF COVERING. Two or more layers of felt cemented together and surfaced with a cap sheet, mineral aggregate, smooth coating or similar surfacing material. [F] BOILING POINT. The temperature at which the vapor pressure of a liquid equals the atmospheric pressure of 14.7 pounds per square inch (psia) (101 kPa) or 760 mm of mercury. Where an accurate boiling point is unavailable for the material in question, or for mixtures which do not have a constant boiling point, for the purposes of this classification, the 20-percent evaporated point of a distillation performed in accordance with ASTM D86 shall be used as the boiling point of the liquid. BURIAL CHAMBER MAUSOLEUM. A family mausoleum consisting of six or fewer casket placement crypts plus a chamber to be used for loading of caskets from the interior of the mausoleum which is not below the level of the ground and which is substantially exposed above ground. [BS] BRACED WALL LINE. A straight line through the building plan that represents the location of the lateral resistance provided by the wall bracing. [BS] BRACED WALL PANEL. A full-height section of wall constructed to resist in-plane shear loads through interaction of framing members, sheathing material and anchors. The panel’s length meets the requirements of its particular bracing method and contributes toward the total amount of bracing required along its braced wall line. BREAKOUT. For revolving doors, a process whereby wings or door panels can be pushed open manually for means of egress travel. [BS] BRICK. Calcium silicate (sand lime brick). A pressed and subsequently autoclaved unit that consists of sand and lime, with or without the inclusion of other materials. Clay or shale. A solid or hollow masonry unit of clay or shale, usually formed into a rectangular prism, then burned or fired in a kiln; brick is a ceramic product. Concrete. A concrete masonry unit made from Portland cement, water, and suitable aggregates, with or without the inclusion of other materials. [A] BUILDING. Any structure used or intended for supporting or sheltering any use or occupancy. BUILDING AREA. See “Area, building.” BUILDING ELEMENT. A fundamental component of building construction, listed in Table 601, which may or may not be of fire-resistance-rated construction and is constructed of materials based on the building type of construction. BUILDING HEIGHT. See “Height, building.” BUILDING-INTEGRATED PHOTOVOLTAIC (BIPV) PRODUCT. A building product that incorporates photovoltaic modules and functions as a component of the building envelope. BUILDING LINE. The line established by law, beyond which a building shall not extend, except as specifically provided by law. 26 CANOPY. A permanent structure or architectural projection of rigid construction over which a covering is attached that provides weather protection, identity or decoration. A canopy is permitted to be structurally independent or supported by attachment to a building on one or more sides. [F] CARBON DIOXIDE EXTINGUISHING SYSTEMS. A system supplying carbon dioxide (CO2) from a pressurized vessel through fixed pipes and nozzles. The system includes a manual- or automatic-actuating mechanism. CARBON MONOXIDE ALARM. A device for the purpose of detecting carbon monoxide, that produces a distinct audible alarm, and is listed or labeled with the appropriate standard, either ANSI/UL 2034, Standard for Single and Multiple Station CO Alarms, or UL 2075, Gas and Vapor Detector Sensor, in accordance with its application. CARE SUITE. In Group I-2 occupancies, a group of treatment rooms, care recipient sleeping rooms and the support rooms or spaces and circulation space within the suite where staff are in attendance for supervision of all care recipients within the suite, and the suite is in compliance with the requirements of Section 407.4.4. [BS] CAST STONE. A building stone manufactured from Portland cement concrete precast and used as a trim, veneer or facing on or in buildings or structures. [F] CEILING LIMIT. The maximum concentration of an airborne contaminant to which one may be exposed. The ceiling limits utilized are those published in DOL 29 CFR Part 1910.1000. The ceiling Recommended Exposure Limit (REL-C) concentrations published by the U.S. National Institute for Occupational Safety and Health (NIOSH), Threshold Limit Value—Ceiling (TLV-C) concentrations published by the American Conference of Governmental Industrial Hygienists (ACGIH), Ceiling Workplace Environmental Exposure Level (WEEL-Ceiling) Guides published by the American Industrial Hygiene Association (AIHA), and other approved, consistent measures are allowed as surrogates for hazardous substances not listed in DOL 29 CFR Part 1910.1000. CEILING RADIATION DAMPER. A listed device installed in a ceiling membrane of a fire-resistance-rated floor/ceiling or roof/ceiling assembly to limit automatically the radiative heat transfer through an air inlet/outlet opening. Ceiling radiation dampers include air terminal units, ceiling dampers and ceiling air diffusers. Ceiling radiation dampers are classified for use in either static systems that will automatically shut down in the event of a fire, or in dynamic sysFLORIDA BUILDING CODE — BUILDING, 8th EDITION (2023) Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 DEFINITIONS tems that continue to operate during a fire. A dynamic ceiling radiation damper is tested and rated for closure under elevated temperature airflow. CELL (Group I-3 occupancy). A room within a housing unit in a detention or correctional facility used to confine inmates or prisoners. [BS] CELL (masonry). A void space having a gross crosssectional area greater than 11/2 square inches (967 mm2). CELL TIER. Levels of cells vertically stacked above one another within a housing unit. [BS] CEMENT PLASTER. A mixture of Portland or blended cement, Portland cement or blended cement and hydrated lime, masonry cement or plastic cement and aggregate and other approved materials as specified in this code. CERAMIC FIBER BLANKET. A high-temperature mineral wool insulation material made of alumina-silica ceramic or calcium magnesium silicate soluble fibers and weighing 4 to 10 pounds per cubic foot (pcf) (64 to 160 kg/m3). CERTIFICATE OF COMPLIANCE. A certificate stating that materials and products meet specified standards or that work was done in compliance with approved construction documents. CHANGE OF OCCUPANCY. Either of the following shall be considered as a change of occupancy where this code requires a greater degree of safety, accessibility, structural strength, fire protection, means of egress, ventilation or sanitation than is existing in the current building or structure: 1. Any change in the occupancy classification of a building or structure. 2. Any change in the purpose of, or a change in the level of activity within, a building or structure. CHAPEL MAUSOLEUM. A mausoleum for the public that has heat or air conditioning, with or without a committal area or office. [M] CHIMNEY. A primarily vertical structure containing one or more flues, for the purpose of carrying gaseous products of combustion and air from a fuel-burning appliance to the outdoor atmosphere. Factory-built chimney. A listed and labeled chimney composed of factory-made components, assembled in the field in accordance with manufacturer’s instructions and the conditions of the listing. Masonry chimney. A field-constructed chimney composed of solid masonry units, bricks, stones, or concrete. Metal chimney. A field-constructed chimney of metal. [M] CHIMNEY TYPES. High-heat appliance type. An approved chimney for removing the products of combustion from fuel-burning, high-heat appliances producing combustion gases in excess of 2000°F (1093°C) measured at the appliance flue outlet (see Section 2113.11.3). Low-heat appliance type. An approved chimney for removing the products of combustion from fuel-burning, low-heat appliances producing combustion gases not in FLORIDA BUILDING CODE — BUILDING, 8th EDITION (2023) excess of 1000°F (538°C) under normal operating conditions, but capable of producing combustion gases of 1400°F (760°C) during intermittent forces firing for periods up to 1 hour. Temperatures shall be measured at the appliance flue outlet. Masonry type. A field-constructed chimney of solid masonry units or stones. Medium-heat appliance type. An approved chimney for removing the products of combustion from fuel-burning, medium-heat appliances producing combustion gases not exceeding 2000°F (1093°C) measured at the appliance flue outlet (see Section 2113.11.2). CIRCULATION PATH. See the Florida Building Code, Accessibility. [F] CLEAN AGENT. Electrically nonconducting, volatile or gaseous fire extinguishant that does not leave a residue upon vaporation. [E] CLIMATE ZONE. A geographical region that has been assigned climatic criteria as specified in Chapters 3CE and 3RE of the Florida Building Code, Energy Conservation. CLINIC, OUTPATIENT. Buildings or portions thereof used to provide medical care on less than a 24-hour basis to persons who are not rendered incapable of self-preservation by the services provided. [F] CLOSED SYSTEM. The use of a solid or liquid hazardous material involving a closed vessel or system that remains closed during normal operations where vapors emitted by the product are not liberated outside of the vessel or system and the product is not exposed to the atmosphere during normal operations; and all uses of compressed gases. Examples of closed systems for solids and liquids include product conveyed through a piping system into a closed vessel, system or piece of equipment. [BS] COASTAL A ZONE. Area within a special flood hazard area, landward of a V zone or landward of an open coast without mapped coastal high hazard areas. In a coastal A zone, the principal source of flooding must be astronomical tides, storm surges, seiches or tsunamis, not riverine flooding. During the base flood conditions, the potential for breaking wave height shall be greater than or equal to 11/2 feet (457 mm). The inland limit of the coastal A zone is (a) the Limit of Moderate Wave Action if delineated on a FIRM, or (b) designated by the authority having jurisdiction. [BS] COASTAL HIGH HAZARD AREA. Area within the special flood hazard area extending from offshore to the inland limit of a primary dune along an open coast and any other area that is subject to high-velocity wave action from storms or seismic sources, and shown on a Flood Insurance Rate Map (FIRM) or other flood hazard map as velocity Zone V, VO, VE or V1-30. [BS] COLLAR JOINT. Vertical longitudinal space between wythes of masonry or between masonry wythe and backup construction that is permitted to be filled with mortar or grout. [BS] COLLECTOR. A horizontal diaphragm element parallel and in line with the applied force that collects and trans27 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 DEFINITIONS fers diaphragm shear forces to the vertical elements of the lateral force-resisting system or distributes forces within the diaphragm, or both. COMMON USE. Interior or exterior circulation paths, rooms, spaces or elements that are not for public use and are made available for the shared use of two or more people. COLUMBARIUM. A permanent structure consisting of niches. COMPANION CRYPT. A permanent chamber in a mausoleum for the containment of human remains of more than one individual. COMBINATION FIRE/SMOKE DAMPER. A listed device installed in ducts and air transfer openings designed to close automatically upon the detection of heat and resist the passage of flame and smoke. The device is installed to operate automatically, controlled by a smoke detection system, and where required, is capable of being positioned from a fire command center. COMBINED PILE RAFT. A geotechnical composite construction that combines the bearing effect of both foundation elements, raft and piles, by taking into account interactions between the foundation elements and the subsoil. [F] COMBUSTIBLE DUST. Finely divided solid material that is 420 microns or less in diameter and which, when dispersed in air in the proper proportions, could be ignited by a flame, spark or other source of ignition. Combustible dust will pass through a U.S. No. 40 standard sieve. [F] COMBUSTIBLE FIBERS. Readily ignitable and freeburning materials in a fibrous or shredded form, such as cocoa fiber, cloth, cotton, excelsior, hay, hemp, henequen, istle, jute, kapok, oakum, rags, sisal, Spanish moss, straw, tow, wastepaper, certain synthetic fibers or other like materials. This definition does not include densely packed baled cotton. [F] COMBUSTIBLE LIQUID. A liquid having a closed cup flash point at or above 100°F (38°C). Combustible liquids shall be subdivided as follows: Class II. Liquids having a closed cup flash point at or above 100°F (38°C) and below 140°F (60°C). Class IIIA. Liquids having a closed cup flash point at or above 140°F (60°C) and below 200°F (93°C). Class IIIB. Liquids having a closed cup flash point at or above 200°F (93°C). The category of combustible liquids does not include compressed gases or cryogenic fluids. COMMERCIAL MOTOR VEHICLE. A motor vehicle used to transport passengers or property where the motor vehicle: 1. Has a gross vehicle weight rating of 10,000 pounds (4540 kg) or more; or 2. Is designed to transport 16 or more passengers, including the driver. COMMISSION. The Florida Building Commission, created per Section 553.74, Florida Statutes. [F] COMPRESSED GAS. A material, or mixture of materials, that: 1. Is a gas at 68°F (20°C) or less at 14.7 pounds per square inch atmosphere (psia) (101 kPa) of pressure; and 2. Has a boiling point of 68°F (20°C) or less at 14.7 psia (101 kPa) which is either liquefied, nonliquefied or in solution, except those gases which have no other health- or physical-hazard properties are not considered to be compressed until the pressure in the packaging exceeds 41 psia (282 kPa) at 68°F (20°C). The states of a compressed gas are categorized as follows: 1. Nonliquefied compressed gases are gases, other than those in solution, which are in a packaging under the charged pressure and are entirely gaseous at a temperature of 68°F (20°C). 2. Liquefied compressed gases are gases that, in a packaging under the charged pressure, are partially liquid at a temperature of 68°F (20°C). 3. Compressed gases in solution are nonliquefied gases that are dissolved in a solvent. 4. Compressed gas mixtures consist of a mixture of two or more compressed gases contained in a packaging, the hazard properties of which are represented by the properties of the mixture as a whole. [BS] CONCRETE. Carbonate aggregate. Concrete made with aggregates consisting mainly of calcium or magnesium carbonate, such as limestone or dolomite, and containing 40 percent or less quartz, chert or flint. Cellular. A lightweight insulating concrete made by mixing a preformed foam with Portland cement slurry and having a dry unit weight of approximately 30 pcf (480 kg/ m3). Lightweight aggregate. Concrete made with aggregates of expanded clay, shale, slag or slate or sintered fly ash or any natural lightweight aggregate meeting ASTM C330 and possessing equivalent fire-resistance properties and weighing 85 to 115 pcf (1360 to 1840 kg/m3). Perlite. A lightweight insulating concrete having a dry unit weight of approximately 30 pcf (480 kg/m3) made with perlite concrete aggregate. Perlite aggregate is produced from a volcanic rock which, when heated, expands to form a glass-like material of cellular structure. COMMON PATH OF EGRESS TRAVEL. That portion of exit access travel distance measured from the most remote point of each room, area or space to that point where the occupants have separate and distinct access to two exits or exit access doorways. Sand-lightweight. Concrete made with a combination of expanded clay, shale, slag, slate, sintered fly ash, or any natural lightweight aggregate meeting ASTM C330 and possessing equivalent fire-resistance properties and natural sand. Its unit weight is generally between 105 and 120 pcf (1680 and 1920 kg/m3). 28 FLORIDA BUILDING CODE — BUILDING, 8th EDITION (2023) Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 DEFINITIONS Siliceous aggregate. Concrete made with normal-weight aggregates consisting mainly of silica or compounds other than calcium or magnesium carbonate, which contains more than 40-percent quartz, chert or flint. Vermiculite. A light weight insulating concrete made with vermiculite concrete aggregate which is laminated micaceous material produced by expanding the ore at high temperatures. When added to a Portland cement slurry the resulting concrete has a dry unit weight of approximately 30 pcf (480 kg/m3). CONGREGATE LIVING FACILITIES. A building or part thereof that contains sleeping units where residents share bathroom or kitchen facilities, or both. CONSTANT LATCHING BOLT. Door-locking hardware installed on the inactive leaf of a pair of doors, which has a bolt that automatically latches into the door frame or the floor, and which holds the inactive leaf in a closed position. The latch bolt is retracted manually to allow the inactive leaf to be opened (see AUTOMATIC FLUSH BOLT, DEAD BOLT, MANUAL BOLT). [F] CONSTANTLY ATTENDED LOCATION. A designated location at a facility staffed by trained personnel on a continuous basis where alarm or supervisory signals are monitored and facilities are provided for notification of the fire department or other emergency services. [A] CONSTRUCTION DOCUMENTS. Written, graphic and pictorial documents prepared or assembled for describing the design, location and physical characteristics of the elements of a project necessary for obtaining a building permit. CONSTRUCTION TYPES. See Section 602. Type I. See Section 602.2. Type II. See Section 602.2. Type III. See Section 602.3. Type IV. See Section 602.4. Type V. See Section 602.5. [F] CONTROL AREA. Spaces within a building where quantities of hazardous materials not exceeding the maximum allowable quantities per control area are stored, dispensed, used or handled. See the definition of “Outdoor control area” in the Florida Fire Prevention Code. CONTROLLED LOW-STRENGTH MATERIAL. A selfcompacted, cementitious material used primarily as a backfill in place of compacted fill. CONVENTIONAL LIGHT-FRAME CONSTRUCTION. Construction whose primary structural elements are formed by a system of repetitive wood-framing members. See Chapter 23 for conventional light-frame construction provisions. CORNICE. A projecting horizontal molded element located at or near the top of an architectural feature. CORRIDOR. An enclosed exit access component that defines and provides a path of egress travel. CORRIDOR, OPEN-ENDED. See “Open-ended corridor.” FLORIDA BUILDING CODE — BUILDING, 8th EDITION (2023) CORRIDOR DAMPER. A listed device intended for use where air ducts penetrate or terminate at horizontal openings in the ceilings of fire-resistance-rated corridors, where the corridor ceiling is permitted to be constructed as required for the corridor walls. [BS] CORROSION RESISTANCE. The ability of a material to withstand deterioration of its surface or its properties when exposed to its environment. [F] CORROSIVE. A chemical that causes visible destruction of, or irreversible alterations in, living tissue by chemical action at the point of contact. A chemical shall be considered corrosive if, when tested on the intact skin of albino rabbits by the method described in DOTn 49 CFR, Part 173.137, such chemical destroys or changes irreversibly the structure of the tissue at the point of contact following an exposure period of 4 hours. This term does not refer to action on inanimate surfaces. COURT. An open, uncovered space, unobstructed to the sky, bounded on three or more sides by exterior building walls or other enclosing devices. COVERED MALL BUILDING. A single building enclosing a number of tenants and occupants, such as retail stores, drinking and dining establishments, entertainment and amusement facilities, passenger transportation terminals, offices and other similar uses wherein two or more tenants have a main entrance into one or more malls. Anchor buildings shall not be considered as a part of the covered mall building. The term “covered mall building” shall include open mall buildings as defined below. Mall. A roofed or covered common pedestrian area within a covered mall building that serves as access for two or more tenants and not to exceed three levels that are open to each other. The term “mall” shall include open malls as defined below. Open mall. An unroofed common pedestrian way serving a number of tenants not exceeding three levels. Circulation at levels above grade shall be permitted to include open exterior balconies leading to exits discharging at grade. Open mall building. Several structures housing a number of tenants, such as retail stores, drinking and dining establishments, entertainment and amusement facilities, offices, and other similar uses, wherein two or more tenants have a main entrance into one or more open malls. Anchor buildings are not considered as a part of the open mall building. [BS] CRIPPLE WALL. A framed stud wall extending from the top of the foundation to the underside of floor framing for the lowest occupied floor level. [F] CRITICAL CIRCUIT. A circuit that requires continuous operation to ensure safety of the structure and occupants. [BS] CROSS-LAMINATED TIMBER. A prefabricated engineered wood product consisting of not less than three layers of solid-sawn lumber or structural composite lumber where the adjacent layers are cross oriented and bonded with structural adhesive to form a solid wood element. 29 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 DEFINITIONS [F] CRYOGENIC FLUID. A liquid having a boiling point lower than -150°F (-101°C) at 14.7 pounds per square inch atmosphere (psia) (an absolute pressure of 101 kPa). CRYPT. A permanent chamber in a mausoleum for the containment of human remains. CUSTODIAL CARE. Assistance with day-to-day living tasks; such as assistance with cooking, taking medication, bathing, using toilet facilities and other tasks of daily living. Custodial care includes persons receiving care who have the ability to respond to emergency situations and evacuate at a slower rate and/or who have mental and psychiatric complications. [BS] DALLE GLASS. A decorative composite glazing material made of individual pieces of glass that are embedded in a cast matrix of concrete or epoxy. DAMPER. See “Ceiling radiation damper,” “Combination fire/smoke damper,” “Corridor damper,” “Fire damper” and “Smoke damper.” [BS] DANGEROUS. Any building, structure or portion thereof that meets any of the conditions described below shall be deemed dangerous: 1. The building or structure has collapsed, has partially collapsed, has moved off its foundation or lacks the necessary support of the ground. 2. There exists a significant risk of collapse, detachment or dislodgment of any portion, member, appurtenance or ornamentation of the building or structure under permanent, routine, or frequent loads; under actual loads already in effect; or under wind, rain, flood, or other environmental loads when such loads are imminent. [F] DAY BOX. A portable magazine designed to hold explosive materials constructed in accordance with the requirements for a Type 3 magazine as defined and classified in the Florida Fire Prevention Code. DEAD BOLT. Door-locking hardware with a bolt which is extended and retracted by action of the lock mechanism (see AUTOMATIC FLUSH BOLT, CONSTANT LATCHING BOLT, MANUAL BOLT). [BS] DEAD LOAD. The weight of materials of construction incorporated into the building, including but not limited to walls, floors, roofs, ceilings, stairways, built-in partitions, finishes, cladding and other similarly incorporated architectural and structural items, and the weight of fixed service equipment, including cranes and material-handling systems. DECORATIVE CEMENTITIOUS FINISH. A skim coat, as defined in ASTM C926, of Portland cement-based plaster applied to concrete or masonry surfaces intended for cosmetic purposes. other effect including, but not limited to, curtains, draperies, fabrics and streamers; and all other materials utilized for decorative effect including, but not limited to, bulletin boards, artwork, posters, photographs, batting, cloth, cotton, hay, stalks, straw, vines, leaves, trees, moss and similar items, foam plastics and materials containing foam plastics. Decorative materials do not include wall coverings, ceiling coverings, floor coverings, ordinary window shades, interior finish and materials 0.025 inch (0.64 mm) or less in thickness applied directly to and adhering tightly to a substrate. [BS] DEEP FOUNDATION. A deep foundation is a foundation element that does not satisfy the definition of a shallow foundation. DEFEND-IN-PLACE. A method of emergency response that engages building components and trained staff to provide occupant safety during an emergency. Emergency response involves remaining in place, relocating within the building, or both, without evacuating the building. [A] DEFERRED SUBMITTAL. Those portions of the design that are not submitted at the time of the application and that are to be submitted to the building official within a specified period. [F] DEFLAGRATION. An exothermic reaction, such as the extremely rapid oxidation of a flammable dust or vapor in air, in which the reaction progresses through the unburned material at a rate less than the velocity of sound. A deflagration can have an explosive effect. DELAYED ACTION CLOSER. Self-closing device that incorporates a delay prior to the initiation of closing. Delayed action closers are mechanical devices with an adjustable delay. [F] DELUGE SYSTEM. A sprinkler system employing open sprinklers attached to a piping system connected to a water supply through a valve that is opened by the operation of a detection system installed in the same areas as the sprinklers. When this valve opens, water flows into the piping system and discharges from all sprinklers attached thereto. [BS] DESIGN FLOOD. The flood associated with the greater of the following two areas: 1. Area with a flood plain subject to a 1-percent or greater chance of flooding in any year. 2. Area designated as a flood hazard area on a community’s flood hazard map, or otherwise legally designated. [BS] DECORATIVE GLASS. A carved, leaded or Dalle glass or glazing material whose purpose is decorative or artistic, not functional; whose coloring, texture or other design qualities or components cannot be removed without destroying the glazing material and whose surface, or assembly into which it is incorporated, is divided into segments. [BS] DESIGN FLOOD ELEVATION. The elevation of the “design flood,” including wave height, relative to the datum specified on the community’s legally designated flood hazard map. In areas designated as Zone AO, the design flood elevation shall be the elevation of the highest existing grade of the building’s perimeter plus the depth number (in feet) specified on the flood hazard map. In areas designated as Zone AO where a depth number is not specified on the map, the depth number shall be taken as being equal to 2 feet (610 mm). [F] DECORATIVE MATERIALS. All materials applied over the building interior finish for decorative, acoustical or [A] DESIGN PROFESSIONAL, REGISTERED. See “Registered design professional.” 30 FLORIDA BUILDING CODE — BUILDING, 8th EDITION (2023) Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 DEFINITIONS [A] DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE, REGISTERED. See “Registered design professional in responsible charge.” [F] DISPENSING. The pouring or transferring of any material from a container, tank or similar vessel, whereby vapors, dusts, fumes, mists or gases are liberated to the atmosphere. [BS] DESIGN STRENGTH. The product of the nominal strength and a resistance factor (or strength reduction factor). DOOR, BALANCED. See “Balanced door.” [F] DETACHED BUILDING. A separate single-story building, without a basement or crawl space, used for the storage or use of hazardous materials and located an approved distance from all structures. [BS] DETAILED PLAIN CONCRETE STRUCTURAL WALL. See Section 1905.1.1 DETECTABLE WARNING. See the Florida Building Code, Accessibility. [F] DETECTOR, HEAT. A fire detector that senses heat— either abnormally high temperature or rate of rise, or both. [F] DETONATION. An exothermic reaction characterized by the presence of a shock wave in the material which establishes and maintains the reaction. The reaction zone progresses through the material at a rate greater than the velocity of sound. The principal heating mechanism is one of shock compression. Detonations have an explosive effect. DETOXIFICATION FACILITIES. Facilities that provide treatment for substance abuse, serving care recipients who are incapable of self-preservation or who are harmful to themselves or others. [BS] DIAPHRAGM. A horizontal or sloped system acting to transmit lateral forces to vertical elements of the lateral forceresisting system. When the term “diaphragm” is used, it shall include horizontal bracing systems. Diaphragm, blocked. In light-frame construction, a diaphragm in which all sheathing edges not occurring on a framing member are supported on and fastened to blocking. Diaphragm boundary. In light-frame construction, a location where shear is transferred into or out of the diaphragm sheathing. Transfer is either to a boundary element or to another force-resisting element. Diaphragm chord. A diaphragm boundary element perpendicular to the applied load that is assumed to take axial stresses due to the diaphragm moment. Diaphragm, unblocked. A diaphragm that has edge nailing at supporting members only. Blocking between supporting structural members at panel edges is not included. Diaphragm panels are field nailed to supporting members. DIMENSIONS (for Chapter 21). Nominal. The specified dimension plus an allowance for the joints with which the units are to be laid. Nominal dimensions are usually stated in whole numbers. Thickness is given first, followed by height and then length. Specified. Dimensions specified for the manufacture or construction of a unit, joint or element. DIRECT ACCESS. A path of travel from a space to an immediately adjacent space through an opening in the common wall between the two spaces. FLORIDA BUILDING CODE — BUILDING, 8th EDITION (2023) DOOR, LOW-ENERGY POWER-OPERATED. See “Lowenergy power-operated door.” DOOR, POWER-ASSISTED. See “Power-assisted door.” DOOR, POWER-OPERATED. See “Power-operated door.” DOORWAY, EXIT ACCESS. See “Exit access doorway.” DORMITORY. A space in a building where group sleeping accommodations are provided in one room, or in a series of closely associated rooms, for persons not members of the same family group, under joint occupancy and single management, as in college dormitories or fraternity houses. DRAFTSTOP. A material, device or construction installed to restrict the movement of air within open spaces of concealed areas of building components such as crawl spaces, floor/ceiling assemblies, roof/ceiling assemblies and attics. [BS] DRAG STRUT. See “Collector.” [BS] DRILLED SHAFT. A cast-in-place deep foundation element, also referred to as caisson, drilled pier and bored pile, constructed by drilling a hole (with or without permanent casing or drilling fluid) into soil or rock and filling it with fluid concrete after the drilling equipment is removed. Socketed drilled shaft. A drilled shaft with a permanent pipe or tube casing that extends down to bedrock and an uncased socket drilled into the bedrock. [F] DRY-CHEMICAL EXTINGUISHING AGENT. A powder composed of small particles, usually of sodium bicarbonate, potassium bicarbonate, urea-potassium-based bicarbonate, potassium chloride or monoammonium phosphate, with added particulate material supplemented by special treatment to provide resistance to packing, resistance to moisture absorption (caking) and the proper flow capabilities. [BS] DRY FLOODPROOFING. A combination of design modifications that results in a building or structure, including the attendant utilities and equipment and sanitary facilities, being water tight with walls substantially impermeable to the passage of water and with structural components having the capacity to resist loads as identified in ASCE 7. DWELLING. A building that contains one or two dwelling units used, intended or designed to be used, rented, leased, let or hired out to be occupied for living purposes. DWELLING UNIT. A single unit providing complete, independent living facilities for one or more persons, including permanent provisions for living, sleeping, eating, cooking and sanitation. DWELLING UNIT, EFFICIENCY. A dwelling unit where all permanent provisions for living, sleeping, eating and cooking are contained in a single room. DWELLING UNIT OR SLEEPING UNIT, MULTISTORY. See “Multistory unit.” DWELLING UNIT OR SLEEPING UNIT, TYPE A. Reserved. 31 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 DEFINITIONS DWELLING UNIT OR SLEEPING UNIT, TYPE B. Reserved. EGRESS COURT. A court or yard which provides access to a public way for one or more exits. ELECTRICAL CIRCUIT PROTECTIVE SYSTEM. A specific construction of devices, materials, or coatings installed as a fire-resistive barrier system applied to electrical system components, such as cable trays, conduits and other raceways, open run cables and conductors, cables, and conductors. [F] ELEVATOR GROUP. A grouping of elevators in a building located adjacent or directly across from one another that responds to common hall call buttons. ENGINEER. A Florida-registered engineer. [BS] ENGINEERED WOOD RIM BOARD. A full-depth structural composite lumber, wood structural panel, structural glued laminated timber or prefabricated wood I-joist member designed to transfer horizontal (shear) and vertical (compression) loads, provide attachment for diaphragm sheathing, siding and exterior deck ledgers, and provide lateral support at the ends of floor or roof joists or rafters. ENTRANCE, PUBLIC. See “Public entrance.” ENTRANCE, RESTRICTED. See “Restricted entrance.” ENTRANCE, SERVICE. See “Service entrance.” [F] EMERGENCY ALARM SYSTEM. A system to provide indication and warning of emergency situations involving hazardous materials. EQUIPMENT PLATFORM. An unoccupied, elevated platform used exclusively for mechanical systems or industrial process equipment, including the associated elevated walkways, stairways, alternating tread devices and ladders necessary to access the platform (see Section 505.3). [F] EMERGENCY CONTROL STATION. An approved location on the premises where signals from emergency equipment are received and which is staffed by trained personnel. ESSENTIAL FACILITIES. Buildings and other structures that are intended to remain operational in the event of extreme environmental loading from flood, wind or tornado. EMERGENCY ESCAPE AND RESCUE OPENING. An operable exterior window, door or other similar device that provides for a means of escape and access for rescue in the event of an emergency. [F] EXHAUSTED ENCLOSURE. An appliance or piece of equipment that consists of a top, a back and two sides providing a means of local exhaust for capturing gases, fumes, vapors and mists. Such enclosures include laboratory hoods, exhaust fume hoods and similar appliances and equipment used to locally retain and exhaust the gases, fumes, vapors and mists that could be released. Rooms or areas provided with general ventilation, in themselves, are not exhausted enclosures. [F] EMERGENCY VOICE/ALARM COMMUNICATIONS. Dedicated manual or automatic facilities for originating and distributing voice instructions, as well as alert and evacuation signals pertaining to a fire emergency, to the occupants of a building. [F] EMERGENCY POWER SYSTEM. A source of automatic electric power of a required capacity and duration to operate required life safety, fire alarm, detection and ventilation systems in the event of a failure of the primary power. Emergency power systems are required for electrical loads where interruption of the primary power could result in loss of human life or serious injuries. EMITTANCE. The ratio of radiant heat flux emitted by a specimen to that emitted by a blackbody at the same temperature and under the same conditions. EMPLOYEE WORK AREA. See the Florida Building Code, Accessibility. ENFORCEMENT AGENCY. Local enforcement agency. An agency of local government, a local school board, a community college board of trustees, or a university board of trustees in the State University System with jurisdiction to make inspections of buildings and to enforce the codes which establish standards for design, construction, erection, alteration, repair, modification, or demolition of public or private buildings, structures, or facilities. State enforcement agency. The agency of state government with authority to make inspections of buildings and to enforce the codes, as required by Chapter 553, Florida Statutes, which establish standards for design, construction, erection, alteration, repair, modification, or demolition of public or private buildings, structures, or facilities. 32 EXISTING BUILDING. A building erected prior to the date of adoption of the appropriate code, or one for which a legal building permit has been issued. [BS] EXISTING STRUCTURE. A structure erected prior to the date of adoption of the appropriate code, or one for which a legal building permit has been issued. EXIT. That portion of a means of egress system between the exit access and the exit discharge or public way. Exit components include exterior exit doors at the level of exit discharge, interior exit stairways and ramps, exit passageways, exterior exit stairways and ramps and horizontal exits. EXIT ACCESS. That portion of a means of egress system that leads from any occupied portion of a building or structure to an exit. EXIT ACCESS DOORWAY. A door or access point along the path of egress travel from an occupied room, area or space where the path of egress enters an intervening room, corridor, exit access stairway or ramp. EXIT ACCESS RAMP. A ramp within the exit access portion of the means of egress system. EXIT ACCESS STAIRWAY. A stairway with the exit access portion of the means of egress system. EXIT DISCHARGE. That portion of a means of egress system between the termination of an exit and a public way. EXIT DISCHARGE, LEVEL OF. The story at the point at which an exit terminates and an exit discharge begins. EXIT, HORIZONTAL. See “Horizontal exit.” FLORIDA BUILDING CODE — BUILDING, 8th EDITION (2023) Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 DEFINITIONS EXIT PASSAGEWAY. An exit component that is separated from other interior spaces of a building or structure by fireresistance-rated construction and opening protectives, and provides for a protected path of egress travel in a horizontal direction to an exit or to the exit discharge. EXPANDED VINYL WALL COVERING. Wall covering consisting of a woven textile backing, an expanded vinyl base coat layer and a nonexpanded vinyl skin coat. The expanded base coat layer is a homogeneous vinyl layer that contains a blowing agent. During processing, the blowing agent decomposes, causing this layer to expand by forming closed cells. The total thickness of the wall covering is approximately 0.055 inch to 0.070 inch (1.4 mm to 1.78 mm). [F] EXPLOSION. An effect produced by the sudden violent expansion of gases, which may be accompanied by a shock wave or disruption, or both, of enclosing materials or structures. An explosion could result from any of the following: 1. Chemical changes such as rapid oxidation, deflagration or detonation, decomposition of molecules and runaway polymerization (usually detonations). 2. Physical changes such as pressure tank ruptures. 3. Atomic changes (nuclear fission or fusion). [F] EXPLOSIVE. A chemical compound, mixture or device, the primary or common purpose of which is to function by explosion. The term includes, but is not limited to, dynamite, black powder, pellet powder, initiating explosives, detonators, safety fuses, squibs, detonating cord, igniter cord, igniters and display fireworks, 1.3G. The term “explosive” includes any material determined to be within the scope of USC Title 18: Chapter 40 and also includes any material classified as an explosive other than consumer fireworks, 1.4G by the hazardous materials regulations of DOTn 49 CFR Parts 100-185. High explosive. Explosive material, such as dynamite, which can be caused to detonate by means of a No. 8 test blasting cap when unconfined. Low explosive. Explosive material that will burn or deflagrate when ignited. It is characterized by a rate of reaction that is less than the speed of sound. Examples of low explosives include, but are not limited to, black powder; safety fuse; igniters; igniter cord; fuse lighters; fireworks, 1.3G and propellants, 1.3C. Mass-detonating explosives. Division 1.1, 1.2 and 1.5 explosives alone or in combination, or loaded into various types of ammunition or containers, most of which can be expected to explode virtually instantaneously when a small portion is subjected to fire, severe concussion, impact, the impulse of an initiating agent or the effect of a considerable discharge of energy from without. Materials that react in this manner represent a mass explosion hazard. Such an explosive will normally cause severe structural damage to adjacent objects. Explosive propagation could occur immediately to other items of ammunition and explosives stored sufficiently close to and not adequately protected from the initially exploding pile with a time interval short enough so that two or more quantities must be considered as one for quantity-distance purposes. FLORIDA BUILDING CODE — BUILDING, 8th EDITION (2023) UN/DOTn Class 1 explosives. The former classification system used by DOTn included the terms “high” and “low” explosives as defined herein. The following terms further define explosives under the current system applied by DOTn for all explosive materials defined as hazard Class 1 materials. Compatibility group letters are used in concert with the division to specify further limitations on each division noted (i.e., the letter G identifies the material as a pyrotechnic substance or article containing a pyrotechnic substance and similar materials). Division 1.1. Explosives that have a mass explosion hazard. A mass explosion is one which affects almost the entire load instantaneously. Division 1.2. Explosives that have a projection hazard but not a mass explosion hazard. Division 1.3. Explosives that have a fire hazard and either a minor blast hazard or a minor projection hazard or both, but not a mass explosion hazard. Division 1.4. Explosives that pose a minor explosion hazard. The explosive effects are largely confined to the package and no projection of fragments of appreciable size or range is to be expected. An external fire must not cause virtually instantaneous explosion of almost the entire contents of the package. Division 1.5. Very insensitive explosives. This division is comprised of substances that have a mass explosion hazard, but that are so insensitive there is very little probability of initiation or of transition from burning to detonation under normal conditions of transport. Division 1.6. Extremely insensitive articles which do not have a mass explosion hazard. This division is comprised of articles that contain only extremely insensitive detonating substances and which demonstrate a negligible probability of accidental initiation or propagation. EXTERIOR ELEVATED FLOORING SYSTEM. An assembly installed over a roof assembly or other exterior supporting structure consisting of a walking surface of pedestrian deck panels or pavers mounted on pedestals using other accessory components, mechanical fasteners or adhesives as required by the manufacturer’s installation instructions for attaching pedestrian deck panels or pavers to pedestals and other accessory components. Exterior elevated flooring systems may have pedestals attached to the roof or other supporting structure or pedestals installed independently of the roof or supporting structure with the restraint of the pavers at the perimeter and discontinuous edges. Exterior elevated flooring systems are not part of the roof assembly. Attached systems. Attached systems are those where pedestals are attached to the roof or other supporting structure by mechanical fasteners, adhesives or both. Independent systems. Independent systems are those where pedestals are not attached to the roof but rest on the roof or other supporting structure. EXTERIOR EXIT RAMP. An exit component that serves to meet one or more means of egress design requirements, such as required number of exits or exit access travel distance, and is open to yards, courts or public ways. 33 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 DEFINITIONS EXTERIOR EXIT STAIRWAY. An exit component that serves to meet one or more means of egress design requirements, such as required number of exits or exit access travel distance, and is open to yards, courts or public ways. EXTERIOR INSULATION AND FINISH SYSTEMS (EIFS). EIFS are nonstructural, nonload-bearing, exterior wall cladding systems that consist of an insulation board attached either adhesively or mechanically, or both, to the substrate; an integrally reinforced base coat and a textured protective finish coat. EXTERIOR INSULATION AND FINISH SYSTEMS (EIFS) WITH DRAINAGE. An EIFS that incorporates a means of drainage applied over a water-resistive barrier. EXTERIOR SURFACES. Weather-exposed surfaces. EXTERIOR WALL. A wall, bearing or nonbearing, that is used as an enclosing wall for a building, other than a fire wall, and that has a slope of 60 degrees (1.05 rad) or greater with the horizontal plane. EXTERIOR WALL COVERING. A material or assembly of materials applied on the exterior side of exterior walls for the purpose of providing a weather-resisting barrier, insulation or for aesthetics, including but not limited to, veneers, siding, exterior insulation and finish systems, architectural trim and embellishments such as cornices, soffits, fascias, gutters and leaders. EXTERIOR WALL ENVELOPE. A system or assembly of exterior wall components, including exterior wall finish materials, that provides protection of the building structural members, including framing and sheathing materials, and conditioned interior space, from the detrimental effects of the exterior environment. F RATING. The time period that the through-penetration firestop system limits the spread of fire through the penetration when tested in accordance with ASTM E814 or UL 1479. FABRIC PARTITION. A partition consisting of a finished surface made of fabric, without a continuous rigid backing, that is directly attached to a framing system in which the vertical framing members are spaced greater than 4 feet (1219 mm) on center. [BS] FABRICATED ITEM. Structural, load-bearing or lateral load-resisting members of assemblies consisting of materials assembled prior to installation in a building or structure, or subjected to operations such as heat treatment, thermal cutting, cold working or reforming after manufacture and prior to installation in a building or structure. Materials produced in accordance with standards referenced by this code, such as rolled structural steel shapes, steel reinforcing bars, masonry units and wood structural panels, or in accordance with a referenced standard that provides requirements for quality control done under the supervision of a third-party quality control agency, are not “fabricated items.” [F] FABRICATION AREA. An area within a semiconductor fabrication facility and related research and development areas in which there are processes using hazardous production materials. Such areas are allowed to include ancillary 34 rooms or areas such as dressing rooms and offices that are directly related to the fabrication area processes. [A] FACILITY. All or any portion of buildings, structures, site improvements, elements and pedestrian or vehicular routes located on a site. [BS] FACTORED LOAD. The product of a nominal load and a load factor. FAMILY MAUSOLEUM. A mausoleum for the private use of a family or group of family members. FENESTRATION. Products classified as either vertical fenestration or skylights and sloped glazing, installed in such a manner as to preserve the weather-resistant barrier of the wall or roof in which they are installed. Fenestration includes products with glass or other transparent or translucent materials. FENESTRATION, VERTICAL. Windows that are fixed or movable, opaque doors, glazed doors, glazed block and combination opaque and glazed doors installed in a wall at less than 15 degrees from vertical. [BS] FIBER-CEMENT (BACKER BOARD, SIDING, SOFFIT, TRIM AND UNDERLAYMENT) PRODUCTS. Manufactured thin section composites of hydraulic cementitious matrices and discrete nonasbestos fibers. FIBER-REINFORCED POLYMER. A polymeric composite material consisting of reinforcement fibers, such as glass, impregnated with a fiber-binding polymer which is then molded and hardened. Fiber-reinforced polymers are permitted to contain cores laminated between fiber-reinforced polymer facings. [BS] FIBERBOARD. A fibrous, homogeneous panel made from lignocellulosic fibers (usually wood or cane) and having a density of less than 31 pounds per cubic foot (pcf) (497 kg/ m3) but more than 10 pcf (160 kg/m3). [BS] FIELD NAILING. See “Nailing, field.” FIRE ALARM BOX, MANUAL. See “Manual fire alarm box.” [F] FIRE ALARM CONTROL UNIT. A system component that receives inputs from automatic and manual fire alarm devices and may be capable of supplying power to detection devices and transponders or off-premises transmitters. The control unit may be capable of providing a transfer of power to the notification appliances and transfer of condition to relays or devices. [F] FIRE ALARM SIGNAL. A signal initiated by a fire alarm-initiating device such as a manual fire alarm box, automatic fire detector, waterflow switch or other device whose activation is indicative of the presence of a fire or fire signature. [F] FIRE ALARM SYSTEM. A system or portion of a combination system consisting of components and circuits arranged to monitor and annunciate the status of fire alarm or supervisory signal-initiating devices and to initiate the appropriate response to those signals. FIRE AREA. The aggregate floor area enclosed and bounded by fire walls, fire barriers, exterior walls or horiFLORIDA BUILDING CODE — BUILDING, 8th EDITION (2023) Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 DEFINITIONS zontal assemblies of a building. Areas of the building not provided with surrounding walls shall be included in the fire area if such areas are included within the horizontal projection of the roof or floor next above. FIRE BARRIER. A fire-resistance-rated wall assembly of materials designed to restrict the spread of fire in which continuity is maintained. [F] FIRE COMMAND CENTER. The principal attended or unattended location where the status of detection, alarm communications and control systems is displayed, and from which the systems can be manually controlled. FIRE DAMPER. A listed device installed in ducts and air transfer openings designed to close automatically upon detection of heat and resist the passage of flame. Fire dampers are classified for use in either static systems that will automatically shut down in the event of a fire, or in dynamic systems that continue to operate during a fire. A dynamic fire damper is tested and rated for closure under elevated temperature airflow. [F] FIRE DETECTOR, AUTOMATIC. A device designed to detect the presence of a fire signature and to initiate action. FIRE DOOR. The door component of a fire door assembly. FIRE DOOR ASSEMBLY. Any combination of a fire door, frame, hardware and other accessories that together provide a specific degree of fire protection to the opening. FIRE DOOR ASSEMBLY, FLOOR. See “Floor fire door assembly.” FIRE EXIT HARDWARE. Panic hardware that is listed for use on fire door assemblies. [F] FIRE LANE. A road or other passageway developed to allow the passage of fire apparatus. A fire lane is not necessarily intended for vehicular traffic other than fire apparatus. FIRE PARTITION. A vertical assembly of materials designed to restrict the spread of fire in which openings are protected. FIRE PROTECTION RATING. The period of time that an opening protective will maintain the ability to confine a fire as determined by tests specified in Section 716. Ratings are stated in hours or minutes. [F] FIRE PROTECTION SYSTEM. Approved devices, equipment and systems or combinations of systems used to detect a fire, activate an alarm, extinguish or control a fire, control or manage smoke and products of a fire or any combination thereof. FIRE RESISTANCE. That property of materials or their assemblies that prevents or retards the passage of excessive heat, hot gases or flames under conditions of use. [F] FIRE SAFETY FUNCTIONS. Building and fire control functions that are intended to increase the level of life safety for occupants or to control the spread of harmful effects of fire. FIRE SEPARATION DISTANCE. The distance measured from the building face to one of the following: 1. The closest interior lot line. FLORIDA BUILDING CODE — BUILDING, 8th EDITION (2023) 2. To the centerline of a street, an alley or public way. 3. To an imaginary line between two buildings on the lot. The distance shall be measured at right angles from the face of the wall. FIRE WALL. A fire-resistance-rated wall having protected openings, which restricts the spread of fire and extends continuously from the foundation to or through the roof, with sufficient structural stability under fire conditions to allow collapse of construction on either side without collapse of the wall. FIRE WINDOW ASSEMBLY. A window constructed and glazed to give protection against the passage of fire. FIREBLOCKING. Building materials, or materials approved for use as fireblocking, installed to resist the free passage of flame to other areas of the building through concealed spaces. [M] FIREPLACE. A hearth and fire chamber or similar prepared place in which a fire may be made and which is built in conjunction with a chimney. FIREPLACE THROAT. The opening between the top of the firebox and the smoke chamber. FIRE-RATED GLAZING. Glazing with either a fire protection rating or a fire-resistance rating. FIRE-RESISTANCE RATING. The period of time a building element, component or assembly maintains the ability to confine a fire, continues to perform a given structural function, or both, as determined by the tests, or the methods based on tests, prescribed in Section 703. FIRE-RESISTANT JOINT SYSTEM. An assemblage of specific materials or products that are designed, tested and fire-resistance rated in accordance with either ASTM E1966 or UL 2079 to resist for a prescribed period of time the passage of fire through joints made in or between fire-resistancerated assemblies. FIRESTOP, MEMBRANE-PENETRATION. See “Membrane-penetration firestop.” FIRESTOP, PENETRATION. See “Penetration firestop.” FIRESTOP SYSTEM, THROUGH-PENETRATION. See “Through-penetration firestop system.” [F] FIREWORKS. Any composition or device for the purpose of producing a visible or audible effect for entertainment purposes by combustion, deflagration or detonation that meets the definition of 1.4G fireworks or 1.3G fireworks. Fireworks, 1.3G. Large fireworks devices, which are explosive materials, intended for use in fireworks displays and designed to produce audible or visible effects by combustion, deflagration or detonation. Such 1.3G fireworks include, but are not limited to, firecrackers containing more than 130 milligrams (2 grains) of explosive composition, aerial shells containing more than 40 grams of pyrotechnic composition, and other display pieces which exceed the limits for classification as 1.4G fireworks. Such 1.3G fireworks are also described as fireworks, UN0335 by the DOTn. 35 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 DEFINITIONS Fireworks, 1.4G. Small fireworks devices containing restricted amounts of pyrotechnic composition designed primarily to produce visible or audible effects by combustion. Such 1.4G fireworks which comply with the construction, chemical composition and labeling regulations of the DOTn for fireworks, UN0336, and the U.S. Consumer Product Safety Commission (CPSC) as set forth in CPSC 16 CFR: Parts 1500 and 1507, are not explosive materials for the purpose of this code. FIXED BASE OPERATOR (FBO). A commercial business granted the right by the airport sponsor to operate on an airport and provide aeronautical services, such as fueling, hangaring, tie-down and parking, aircraft rental, aircraft maintenance and flight instruction. FIXED SEATING. Furniture or fixture designed and installed for the use of sitting and secured in place including bench-type seats and seats with or without backs or arm rests. FLAME SPREAD. The propagation of flame over a surface. FLAME SPREAD INDEX. A comparative measure, expressed as a dimensionless number, derived from visual measurements of the spread of flame versus time for a material tested in accordance with ASTM E84 or UL 723. [F] FLAMMABLE GAS. A material that is a gas at 68°F (20°C) or less at 14.7 pounds per square inch atmosphere (psia) (101 kPa) of pressure [a material that has a boiling point of 68°F (20°C) or less at 14.7 psia (101 kPa)] which: 1. Is ignitable at 14.7 psia (101 kPa) when in a mixture of 13 percent or less by volume with air; or 2. Has a flammable range at 14.7 psia (101 kPa) with air of at least 12 percent, regardless of the lower limit. The limits specified shall be determined at 14.7 psi (101 kPa) of pressure and a temperature of 68°F (20°C) in accordance with ASTM E681. [F] FLAMMABLE LIQUEFIED GAS. A liquefied compressed gas which, under a charged pressure, is partially liquid at a temperature of 68°F (20°C) and which is flammable. has an ignition temperature below 212°F (100°C) or which burns so vigorously and persistently when ignited as to create a serious hazard. A chemical shall be considered a flammable solid as determined in accordance with the test method of CPSC 16 CFR; Part 1500.44, if it ignites and burns with a self-sustained flame at a rate greater than 0.1 inch (2.5 mm) per second along its major axis. [F] FLAMMABLE VAPORS OR FUMES. The concentration of flammable constituents in air that exceeds 25 percent of their lower flammable limit (LFL). [F] FLASH POINT. The minimum temperature in degrees Fahrenheit at which a liquid will give off sufficient vapors to form an ignitable mixture with air near the surface or in the container, but will not sustain combustion. The flash point of a liquid shall be determined by appropriate test procedure and apparatus as specified in ASTM D56, ASTM D93 or ASTM D3278. FLIGHT. A continuous run of rectangular treads, winders or combination thereof from one landing to another. FLOATING RESIDENTIAL UNIT. A structure primarily designed or constructed as a living unit, built on a floating base, which is not designed primarily as a vessel, is not selfpropelled although it may be towed about from place to place, and is primarily intended to be anchored or otherwise moored in a fixed location. [BS] FLOOD or FLOODING. A general and temporary condition of partial or complete inundation of normally dry land from: 1. The overflow of inland or tidal waters. 2. The unusual and rapid accumulation or runoff of surface waters from any source. [BS] FLOOD DAMAGE-RESISTANT MATERIALS. Any construction material capable of withstanding direct and prolonged contact with floodwaters without sustaining any damage that requires more than cosmetic repair. FLOOD, DESIGN. See “Design flood.” [F] FLAMMABLE LIQUID. A liquid having a closed cup flash point below 100°F (38°C). Flammable liquids are further categorized into a group known as Class I liquids. The Class I category is subdivided as follows: FLOOD ELEVATION, DESIGN. See “Design flood elevation.” Class IA. Liquids having a flash point below 73°F (23°C) and a boiling point below 100°F (38°C). 1. The area within a flood plain subject to a 1-percent or greater chance of flooding in any year. Class IB. Liquids having a flash point below 73°F (23°C) and a boiling point at or above 100°F (38°C). 2. The area designated as a flood hazard area on a community’s flood hazard map, or otherwise legally designated. FLOOD HAZARD AREAS, SPECIAL. See “Special flood hazard area.” Class IC. Liquids having a flash point at or above 73°F (23°C) and below 100°F (38°C). The category of flammable liquids does not include compressed gases or cryogenic fluids. [F] FLAMMABLE MATERIAL. A material capable of being readily ignited from common sources of heat or at a temperature of 600°F (316°C) or less. [F] FLAMMABLE SOLID. A solid, other than a blasting agent or explosive, that is capable of causing fire through friction, absorption or moisture, spontaneous chemical change, or retained heat from manufacturing or processing, or which 36 [BS] FLOOD HAZARD AREA. The greater of the following two areas: [BS] FLOOD INSURANCE RATE MAP (FIRM). An official map of a community on which the Federal Emergency Management Agency (FEMA) has delineated both the special flood hazard areas and the risk premium zones applicable to the community. [BS] FLOOD INSURANCE STUDY. The official report provided by the Federal Emergency Management Agency containing the Flood Insurance Rate Map (FIRM), the Flood FLORIDA BUILDING CODE — BUILDING, 8th EDITION (2023) Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 DEFINITIONS Boundary and Floodway Map (FBFM), the water surface elevation of the base flood and supporting technical data. [BS] FLOODWAY. The channel of the river, creek or other watercourse and the adjacent land areas that must be reserved in order to discharge the base flood without cumulatively increasing the water surface elevation more than a designated height. FLOOR AREA, GROSS. The floor area within the inside perimeter of the exterior walls of the building under consideration, exclusive of vent shafts and courts, without deduction for corridors, stairways, ramps, closets, the thickness of interior walls, columns or other features. The floor area of a building, or portion thereof, not provided with surrounding exterior walls shall be the usable area under the horizontal projection of the roof or floor above. The gross floor area shall not include shafts with no openings or interior courts. GARDEN MAUSOLEUM. A mausoleum for the public built without heat or air conditioning but may contain an open-air committal area. [F] GAS CABINET. A fully enclosed, ventilated noncombustible enclosure used to provide an isolated environment for compressed gas cylinders in storage or use. Doors and access ports for exchanging cylinders and accessing pressureregulating controls are allowed to be included. [F] GAS DETECTION SYSTEM. A system or portion of a combination system that utilizes one or more stationary sensors to detect the presence of a specified gas at a specified concentration and initiate one or more responses required by this code, such as notifying a responsible person, activating an alarm signal, or activating or deactivating equipment. A self-contained gas detection and alarm device is not classified as a gas detection system. FLOOR AREA, NET. The actual occupied area not including unoccupied accessory areas such as corridors, stairways, ramps, toilet rooms, mechanical rooms and closets. [F] GAS ROOM. A separately ventilated, fully enclosed room in which only compressed gases and associated equipment and supplies are stored or used. FLOOR FIRE DOOR ASSEMBLY. A combination of a fire door, a frame, hardware and other accessories installed in a horizontal plane, which together provide a specific degree of fire protection to a through-opening in a fire-resistancerated floor (see Section 712.1.13.1). [F] GASEOUS HYDROGEN SYSTEM. An assembly of piping, devices and apparatus designed to generate, store, contain, distribute or transport a nontoxic, gaseous hydrogencontaining mixture having not less than 95-percent hydrogen gas by volume and not more than 1-percent oxygen by volume. Gaseous hydrogen systems consist of items such as compressed gas containers, reactors and appurtenances, including pressure regulators, pressure relief devices, manifolds, pumps, compressors and interconnecting piping and tubing and controls. [F] FOAM-EXTINGUISHING SYSTEM. A special system discharging a foam made from concentrates, either mechanically or chemically, over the area to be protected. FOAM PLASTIC INSULATION. A plastic that is intentionally expanded by the use of a foaming agent to produce a reduced-density plastic containing voids consisting of open or closed cells distributed throughout the plastic for thermal insulating or acoustical purposes and that has a density less than 20 pounds per cubic foot (pcf) (320 kg/m3). FOLDING AND TELESCOPIC SEATING. Tiered seating having an overall shape and size that is capable of being reduced for purposes of moving or storing and is not a building element. FOOD COURT. A public seating area located in the mall that serves adjacent food preparation tenant spaces. FOSTER CARE FACILITIES. Facilities that provide care to more than five children, 21/2 years of age or less. [BS] FOUNDATION PIER (for Chapter 21). An isolated vertical foundation member whose horizontal dimension measured at right angles to its thickness does not exceed three times its thickness and whose height is equal to or less than four times its thickness. FRAME STRUCTURE. A building or other structure in which vertical loads from floors and roofs are primarily supported by columns. GABLE. The triangular portion of a wall beneath the end of a dual-slope, pitched, or mono-slope roof or portion thereof and above the top plates of the story or level of the ceiling below. GARAGE DOOR MANUFACTURER. The party responsible for the completed assembly of the garage door components. FLORIDA BUILDING CODE — BUILDING, 8th EDITION (2023) GLASS FIBERBOARD. Fibrous glass roof insulation consisting of inorganic glass fibers formed into rigid boards using a binder. The board has a top surface faced with asphalt and kraft reinforced with glass fiber. GLASS MAT GYPSUM PANEL. A gypsum panel consisting of a noncombustible core primarily of gypsum, surfaced with glass mat partially or completely embedded in the core. [BS] GRADE (LUMBER). The classification of lumber in regard to strength and utility in accordance with American Softwood Lumber Standard DOC PS 20 and the grading rules of an approved lumber rules-writing agency. GRADE PLANE. A reference plane representing the average of finished ground level adjoining the building at exterior walls. Where the finished ground level slopes away from the exterior walls, the reference plane shall be established by the lowest points within the area between the building and the lot line or, where the lot line is more than 6 feet (1829 mm) from the building, between the building and a point 6 feet (1829 mm) from the building. GRADE PLANE, STORY ABOVE. See “Story above grade plane.” GRANDSTAND. Tiered seating supported on a dedicated structural system and two or more rows high and is not a building element (see “Bleachers”). GROSS LEASABLE AREA. The total floor area designed for tenant occupancy and exclusive use. The area of tenant occupancy is measured from the centerlines of joint partitions 37 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 DEFINITIONS to the outside of the tenant walls. All tenant areas, including areas used for storage, shall be included in calculating gross leasable area. GROUP HOME. A facility for social rehabilitation, substance abuse or mental health problems that contains a group housing arrangement that provides custodial care but does not provide medical care. GUARD. A building component or a system of building components located at or near the open sides of elevated walking surfaces that minimizes the possibility of a fall from the walking surface to a lower level. GUEST ROOM. A room used or intended to be used by one or more guests for living or sleeping purposes. GYPSUM BOARD. The generic name for a family of sheet products consisting of a noncombustible core primarily of gypsum with paper surfacing. [BS] GYPSUM PANEL PRODUCT. The general name for a family of sheet products consisting essentially of gypsum complying with the standards specified in Tables 2506.2 and 2507.2, and Chapter 35. Gypsum board and glass mat gypsum panels are examples of gypsum panel products. [BS] GYPSUM PLASTER. A mixture of calcined gypsum or calcined gypsum and lime and aggregate and other approved materials as specified in this code. GYPSUM SHEATHING. Gypsum panel products specifically manufactured with enhanced water resistance for use as a substrate for exterior surface materials. [BS] GYPSUM VENEER PLASTER. Gypsum plaster applied to an approved base in one or more coats normally not exceeding 1/4 inch (6.4 mm) in total thickness. GYPSUM WALLBOARD. A gypsum board used primarily as an interior surfacing for building structures. fied in Section 307 and the Florida Fire Prevention Code, whether the materials are in usable or waste condition. [F] HAZARDOUS PRODUCTION MATERIAL (HPM). A solid, liquid or gas associated with semiconductor manufacturing that has a degree-of-hazard rating in health, flammability or instability of Class 3 or 4 as ranked by NFPA 704 and which is used directly in research, laboratory or production processes which have as their end product materials that are not hazardous. [BS] HEAD JOINT. Vertical mortar joint placed between masonry units within the wythe at the time the masonry units are laid. [F] HEALTH HAZARD. A classification of a chemical for which there is statistically significant evidence that acute or chronic health effects are capable of occurring in exposed persons. The term “health hazard” includes chemicals that are toxic or highly toxic, and corrosive. HEAT DETECTOR. See “Detector, heat.” HEIGHT, BUILDING. The vertical distance from grade plane to the average height of the highest roof surface. HEIGHT, THRESHOLD BUILDING. The height of the building is at the mean distance between the eaves and the ridge of the roofing structure. If the distance from grade to the line which is the mean distance between the eaves and the ridge of the roofing structure is more than 50 feet (16 240 mm), the building is to be considered a “threshold building” within the contemplation of the Threshold Building Act. HELICAL PILE. Manufactured steel deep foundation element consisting of a central shaft and one or more helical bearing plates. A helical pile is installed by rotating it into the ground. Each helical bearing plate is formed into a screw thread with a uniform defined pitch. HELIPAD. A structural surface that is used for the landing, taking off, taxiing and parking of helicopters. HABITABLE SPACE. A space in a building for living, sleeping, eating or cooking. Bathrooms, toilet rooms, closets, halls, screen enclosures, sunroom Categories I, II, III and IV as defined in Section 2002.6, storage or utility spaces and similar areas are not considered habitable spaces. HELIPORT. An area of land or water or a structural surface that is used, or intended for use, for the landing and taking off of helicopters, and any appurtenant areas that are used, or intended for use, for heliport buildings or other heliport facilities. [F] HALOGENATED EXTINGUISHING SYSTEM. A fire-extinguishing system using one or more atoms of an element from the halogen chemical series: fluorine, chlorine, bromine and iodine. HELISTOP. The same as “heliport,” except that no fueling, defueling, maintenance, repairs or storage of helicopters is permitted. [F] HANDLING. The deliberate transport by any means to a point of storage or use. HANDRAIL. A horizontal or sloping rail intended for grasping by the hand for guidance or support. HARDBOARD. A fibrous-felted, homogeneous panel made from lignocellulosic fibers consolidated under heat and pressure in a hot press to a density not less than 31 pcf (497 kg/ m3). HARDWARE. See “Fire exit hardware” and “Panic hardware.” [F] HAZARDOUS MATERIALS. Those chemicals or substances that are physical hazards or health hazards as classi38 HIGH-PRESSURE DECORATIVE EXTERIOR-GRADE COMPACT LAMINATE (HPL). Panels consisting of layers of cellulose fibrous material impregnated with thermosetting resins and bonded together by a high-pressure process to form a homogeneous nonporous core suitable for exterior use. HIGH-PRESSURE DECORATIVE EXTERIOR-GRADE COMPACT LAMINATE (HPL) SYSTEM. An exterior wall covering fabricated using HPL in a specific assembly including joints, seams, attachments, substrate, framing and other details as appropriate to a particular design. HIGH-RISE BUILDING. A building with an occupied floor located more than 75 feet (22 860 mm) above the lowest level of fire department vehicle access. FLORIDA BUILDING CODE — BUILDING, 8th EDITION (2023) Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 DEFINITIONS HIGH VELOCITY HURRICANE ZONE. This zone consists of Broward and Miami-Dade counties. 2. Hawaii, Puerto Rico, Guam, Virgin Islands and American Samoa. [F] HIGHLY TOXIC. A material which produces a lethal dose or lethal concentration that falls within any of the following categories: [F] HYDROGEN FUEL GAS ROOM. A room or space that is intended exclusively to house a gaseous hydrogen system. 1. A chemical that has a median lethal dose (LD50) of 50 milligrams or less per kilogram of body weight when administered orally to albino rats weighing between 200 and 300 grams each. [BS] ICE-SENSITIVE STRUCTURE. A structure for which the effect of an atmospheric ice load governs the design of a structure or portion thereof. This includes, but is not limited to, lattice structures, guyed masts, overhead lines, light suspension and cable-stayed bridges, aerial cable systems (e.g., for ski lifts or logging operations), amusement rides, open catwalks and platforms, flagpoles and signs. 2. A chemical that has a median lethal dose (LD50) of 200 milligrams or less per kilogram of body weight when administered by continuous contact for 24 hours (or less if death occurs within 24 hours) with the bare skin of albino rabbits weighing between 2 and 3 kilograms each. 3. A chemical that has a median lethal concentration (LC50) in air of 200 parts per million by volume or less of gas or vapor, or 2 milligrams per liter or less of mist, fume or dust, when administered by continuous inhalation for 1 hour (or less if death occurs within 1 hour) to albino rats weighing between 200 and 300 grams each. Mixtures of these materials with ordinary materials, such as water, might not warrant classification as highly toxic. While this system is basically simple in application, any hazard evaluation that is required for the precise categorization of this type of material shall be performed by experienced, technically competent persons. [A] HISTORIC BUILDINGS. Buildings that are listed in or eligible for listing in the National Register of Historic Places, or designated as historic under an appropriate state or local law (see Chapter 12 of the Florida Building Code, Existing Building). HORIZONTAL ASSEMBLY. A fire-resistance-rated floor or roof assembly of materials designed to restrict the spread of fire in which continuity is maintained. HORIZONTAL EXIT. An exit component consisting of fireresistance-rated construction and opening protectives intended to compartmentalize portions of a building or another building thereby creating refuge areas that afford safety from the fire and smoke from the area of fire origin. HOSPITALS AND PSYCHIATRIC HOSPITALS. Facilities that provide care or treatment for the medical, psychiatric, obstetrical, or surgical treatment of care recipients who are incapable of self-preservation. HOUSING UNIT. A dormitory or a group of cells with a common dayroom in Group I-3. [F] HPM. See “Hazardous Production Material.” [F] HPM ROOM. A room used in conjunction with or serving a Group H-5 occupancy, where HPM is stored or used and which is classified as a Group H-2, H-3 or H-4 occupancy. [BS] HURRICANE-PRONE REGIONS. Areas vulnerable to hurricanes defined as: 1. The U. S. Atlantic Ocean and Gulf of Mexico coasts where the ultimate design wind speed, Vult, for Risk Category II buildings is greater than 115 mph (51.4 m/s); FLORIDA BUILDING CODE — BUILDING, 8th EDITION (2023) [F] IMMEDIATELY DANGEROUS TO LIFE AND HEALTH (IDLH). The concentration of airborne contaminants which poses a threat of death, immediate or delayed permanent adverse health effects, or effects that could prevent escape from such an environment. This contaminant concentration level is established by the National Institute of Occupational Safety and Health (NIOSH) based on both toxicity and flammability. It generally is expressed in parts per million by volume (ppmv/v) or milligrams per cubic meter (mg/m3). If adequate data do not exist for precise establishment of IDLH concentrations, an independent certified industrial hygienist, industrial toxicologist, appropriate regulatory agency or other source approved by the building official shall make such determination. [BS] IMPACT LOAD. The load resulting from moving machinery, elevators, craneways, vehicles and other similar forces and kinetic loads, pressure and possible surcharge from fixed or moving loads. INCAPABLE OF SELF-PRESERVATION. Persons who, because of age, physical limitations, mental limitations, chemical dependency or medical treatment, cannot respond as an individual to an emergency situation. [F] INCOMPATIBLE MATERIALS. Materials that, when mixed, have the potential to react in a manner that generates heat, fumes, gases or byproducts which are hazardous to life or property. INDIVIDUAL TRUSS MEMBER. A truss chord or truss web. [F] INERT GAS. A gas that is capable of reacting with other materials only under abnormal conditions such as high temperatures, pressures and similar extrinsic physical forces. Within the context of the code, inert gases do not exhibit either physical or health hazard properties as defined (other than acting as a simple asphyxiant) or hazard properties other than those of a compressed gas. Some of the more common inert gases include argon, helium, krypton, neon, nitrogen and xenon. [F] INITIATING DEVICE. A system component that originates transmission of a change-of-state condition, such as in a smoke detector, manual fire alarm box or supervisory switch. INSULATING SHEATHING. A rigid panel or board insulation material having a thermal resistance of not less than R-2 of the core material with properties suitable for use on walls, floors, roofs or foundations. 39 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 DEFINITIONS INTENDED TO BE OCCUPIED AS A RESIDENCE. This refers to a dwelling unit or sleeping unit that can or will be used all or part of the time as the occupant’s place of abode. INTERIOR EXIT RAMP. An exit component that serves to meet one or more means of egress design requirements, such as required number of exits or exit access travel distance, and provides for a protected path of egress travel to the exit discharge or public way. [A] LABELED. Equipment, materials or products to which has been affixed a label, seal, symbol or other identifying mark of a nationally recognized testing laboratory, approved agency or other organization concerned with product evaluation that maintains periodic inspection of the production of the above-labeled items and whose labeling indicates either that the equipment, material or product meets identified standards or has been tested and found suitable for a specified purpose. INTERIOR EXIT STAIRWAY. An exit component that serves to meet one or more means of egress design requirements, such as required number of exits or exit access travel distance, and provides for a protected path of egress travel to the exit discharge or public way. LANDSCAPE ARCHITECT. A Florida-registered landscape architect. INTERIOR FINISH. Interior finish includes interior wall and ceiling finish and interior floor finish. INTERIOR FLOOR FINISH. The exposed floor surfaces of buildings including coverings applied over a finished floor or stair, including risers. INTERIOR FLOOR-WALL BASE. Interior floor finish trim used to provide a functional or decorative border at the intersection of walls and floors. INTERIOR SURFACES. Surfaces other than weather exposed surfaces. INTERIOR WALL AND CEILING FINISH. The exposed interior surfaces of buildings, including but not limited to: fixed or movable walls and partitions; toilet room privacy partitions; columns; ceilings; and interior wainscoting, paneling or other finish applied structurally or for decoration, acoustical correction, surface insulation, structural fire resistance or similar purposes, but not including trim. [BS] INTERLAYMENT. A layer of felt or nonbituminous saturated felt not less than 18 inches (457 mm) wide, shingled between each course of a wood-shake roof covering. INTUMESCENT FIRE-RESISTIVE MATERIAL. Liquid mixture applied to substrates by brush, roller, spray or trowel which expands into a protective foamed layer to provide fireresistive protection of the substrates when exposed to flame or intense heat. [BS] JOINT. The opening in or between adjacent assemblies that is created due to building tolerances, or is designed to allow independent movement of the building in any plane caused by thermal, wind or any other loading. [A] JURISDICTION. The governmental unit that has adopted this code under due legislative authority. L RATING. The air leakage rating of a through penetration firestop system or a fire-resistant joint system when tested in accordance with UL 1479 or UL 2079, respectively. [A] LABEL. An identification applied on a product by the manufacturer that contains the name of the manufacturer, the function and performance characteristics of the product or material and the name and identification of an approved agency, and that indicates that the representative sample of the product or material has been tested and evaluated by an approved agency (see Section 1703.5, “Manufacturer’s designation” and “Mark”). 40 LEVEL OF EXIT DISCHARGE. See “Exit discharge, level of.” LIGHT-DIFFUSING SYSTEM. Construction consisting in whole or in part of lenses, panels, grids or baffles made with light-transmitting plastics positioned below independently mounted electrical light sources, skylights or light-transmitting plastic roof panels. Lenses, panels, grids and baffles that are part of an electrical fixture shall not be considered as a light-diffusing system. LIGHT-FRAME CONSTRUCTION. Construction whose vertical and horizontal structural elements are primarily formed by a system of repetitive wood or cold-formed steel framing members. LIGHT-TRANSMITTING PLASTIC ROOF PANELS. Structural plastic panels other than skylights that are fastened to structural members, or panels or sheathing and that are used as light-transmitting media in the plane of the roof. LIGHT-TRANSMITTING PLASTIC WALL PANELS. Plastic materials that are fastened to structural members, or to structural panels or sheathing, and that are used as light-transmitting media in exterior walls. [BS] LIMIT OF MODERATE WAVE ACTION. Line shown on FIRMs to indicate the inland limit of the 11/2-foot (457 mm) breaking wave height during the base flood. [BS] LIMIT STATE. A condition beyond which a structure or member becomes unfit for service and is judged to be no longer useful for its intended function (serviceability limit state) or to be unsafe (strength limit state). [F] LIQUID. A material that has a melting point that is equal to or less than 68°F (20°C) and a boiling point that is greater than 68°F (20°C) at 14.7 pounds per square inch absolute (psia) (101 kPa). When not otherwise identified, the term “liquid” includes both flammable and combustible liquids. [F] LIQUID STORAGE ROOM. A room classified as a Group H-3 occupancy used for the storage of flammable or combustible liquids in a closed condition. [F] LIQUID USE, DISPENSING AND MIXING ROOM. A room in which Class I, II and IIIA flammable or combustible liquids are used, dispensed or mixed in open containers. [A] LISTED. Equipment, materials, products or services included in a list published by an organization acceptable to the building official and concerned with evaluation of products or services that maintains periodic inspection of production of listed equipment or materials or periodic evaluation of services and whose listing states either that the equipment, FLORIDA BUILDING CODE — BUILDING, 8th EDITION (2023) Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 DEFINITIONS material, product or service meets identified standards or has been tested and found suitable for a specified purpose. will occur in the presence of an ignition source. The LFL is sometimes referred to as “LEL” or “lower explosive limit.” [BS] LIVE LOAD. A load produced by the use and occupancy of the building or other structure that does not include construction or environmental loads such as wind load, rain load, flood load or dead load. [BS] LOWEST FLOOR. The lowest floor of the lowest enclosed area, including basement, but excluding any unfinished or flood-resistant enclosure, usable solely for vehicle parking, building access or limited storage provided that such enclosure is not built so as to render the structure in violation of Section 1612. [BS] LIVE LOAD, ROOF. A load on a roof produced: 1. During maintenance by workers, equipment and materials; or 2. During the life of the structure by movable objects such as planters or other similar small decorative appurtenances that are not occupancy related. LIVE/WORK UNIT. A dwelling unit or sleeping unit in which a significant portion of the space includes a nonresidential use that is operated by the tenant. [BS] LOAD AND RESISTANCE FACTOR DESIGN (LRFD). A method of proportioning structural members and their connections using load and resistance factors such that no applicable limit state is reached when the structure is subjected to appropriate load combinations. The term “LRFD” is used in the design of steel and wood structures. [BS] LOAD EFFECTS. Forces and deformations produced in structural members by the applied loads. [BS] LOAD FACTOR. A factor that accounts for deviations of the actual load from the nominal load, for uncertainties in the analysis that transforms the load into a load effect, and for the probability that more than one extreme load will occur simultaneously. [BS] LOADS. Forces or other actions that result from the weight of building materials, occupants and their possessions, environmental effects, differential movement and restrained dimensional changes. Permanent loads are those loads in which variations over time are rare or of small magnitude, such as dead loads. All other loads are variable loads (see “Nominal loads”). LOCAL FLOOD PLAIN MANAGEMENT ORDINANCE. An ordinance or regulation adopted pursuant to the requirements in Title 44 Code of Federal Regulations, Parts 59 and 60 for participation in the National Flood Insurance Program. LODGING HOUSE. A one-family dwelling where one or more occupants are primarily permanent in nature and rent is paid for guest rooms. [A] LOT. A portion or parcel of land considered as a unit. [A] LOT LINE. A line dividing one lot from another, or from a street or any public place. LOW-ENERGY POWER-OPERATED DOOR. A swinging, sliding or folding door that opens automatically upon an action by a pedestrian such as pressing a push plate or waving a hand in front of a sensor. The door closes automatically, and operates with decreased forces and decreased speeds (see “Power-assisted door” and “Power-operated door”). [F] LOWER FLAMMABLE LIMIT (LFL). The minimum concentration of vapor in air at which propagation of flame FLORIDA BUILDING CODE — BUILDING, 8th EDITION (2023) [BS] MAIN WINDFORCE-RESISTING SYSTEM. An assemblage of structural elements assigned to provide support and stability for the overall structure. The system generally receives wind loading from more than one surface. MALL BUILDING, COVERED and MALL BUILDING, OPEN. See “Covered mall building.” MANUAL BOLT. Door-locking hardware operable from one side of the door, or from the edge of a door leaf, with a bolt or rod extended and retracted by manual movement of the bolt or rod, such as a manual flush bolt or manual surface bolt (see AUTOMATIC FLUSH BOLT, CONSTANT LATCHING BOLT, DEAD BOLT). [F] MANUAL FIRE ALARM BOX. A manually operated device used to initiate an alarm signal. [A] MANUFACTURER’S DESIGNATION. An identification applied on a product by the manufacturer indicating that a product or material complies with a specified standard or set of rules (see “Label” and “Mark”). [A] MARK. An identification applied on a product by the manufacturer indicating the name of the manufacturer and the function of a product or material (see “Label” and “Manufacturer’s designation”). MARQUEE. A canopy that has a top surface which is sloped less than 25 degrees from the horizontal and is located less than 10 feet (3048 mm) from operable openings above or adjacent to the level of the marquee. [BS] MASONRY. A built-up construction or combination of building units or materials of clay, shale, concrete, glass, gypsum, stone or other approved units bonded together with or without mortar or grout or other accepted methods of joining. Glass unit masonry. Masonry composed of glass units bonded by mortar. Plain masonry. Masonry in which the tensile resistance of the masonry is taken into consideration and the effects of stresses in reinforcement are neglected. Reinforced masonry. Masonry construction in which reinforcement acting in conjunction with the masonry is used to resist forces. Solid masonry. Masonry consisting of solid masonry units laid contiguously with the joints between the units filled with mortar. Unreinforced (plain) masonry. Masonry in which the tensile resistance of masonry is taken into consideration and the resistance of the reinforcing steel, if present, is neglected. 41 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 DEFINITIONS [BS] MASONRY UNIT. Brick, tile, stone, glass block or concrete block conforming to the requirements specified in Section 2103. Hollow. A masonry unit whose net cross-sectional area in any plane parallel to the load-bearing surface is less than 75 percent of its gross cross-sectional area measured in the same plane. Solid. A masonry unit whose net cross-sectional area in every plane parallel to the load-bearing surface is 75 percent or more of its gross cross-sectional area measured in the same plane. MATERIAL CODE VIOLATION. A material code violation is a violation that exists within a completed building, structure or facility which may reasonably result, or has resulted, in physical harm to a person or significant damage to the performance of a building or its systems. MATERIAL VIOLATION. As defined in Florida Statutes. a rigid framework to support a tensioned membrane which provides the weather barrier. MEMBRANE PENETRATION. A breach in one side of a floor-ceiling, roof-ceiling or wall assembly to accommodate an item installed into or passing through the breach. MEMBRANE-PENETRATION FIRESTOP. A material, device or construction installed to resist for a prescribed time period the passage of flame and heat through openings in a protective membrane in order to accommodate cables, cable trays, conduit, tubing, pipes or similar items. MEMBRANE-PENETRATION FIRESTOP SYSTEM. An assemblage consisting of a fire-resistance-rated floor-ceiling, roof-ceiling or wall assembly, one or more penetrating items installed into or passing through the breach in one side of the assembly and the materials or devices, or both, installed to resist the spread of fire into the assembly for a prescribed period of time. MAUSOLEUM. A permanent structure or building which is substantially exposed above the ground and is intended for the interment, entombment, or inurnment of human remains. MEANS OF EGRESS. A continuous and unobstructed path of vertical and horizontal egress travel from any occupied portion of a building or structure to a public way. A means of egress consists of three separate and distinct parts: the exit access, the exit and the exit discharge. MERCHANDISE PAD. A merchandise pad is an area for display of merchandise surrounded by aisles, permanent fixtures or walls. Merchandise pads contain elements such as nonfixed and moveable fixtures, cases, racks, counters and partitions from which customers browse or shop. MEANS OF ESCAPE. As used in Section 1010.3.5, a way out of a building or structure that does not conform to the strict definition of means of egress but does provide an alternate way out. A means of escape consists of a door, stairway, passage or hall providing a way of unobstructed travel to the outside at street or ground level. It may also consist of a passage through an adjacent nonlockable space, independent of and remotely located from the means of egress, to any approved exit. METAL COMPOSITE MATERIAL (MCM) SYSTEM. An exterior wall covering fabricated using MCM in a specific assembly including joints, seams, attachments, substrate, framing and other details as appropriate to a particular design. [BG] MECHANICAL-ACCESS ENCLOSED PARKING GARAGE. An enclosed parking garage that employs parking machines, lifts, elevators or other mechanical devices for vehicle moving from and to street level and in which public occupancy in the garage is prohibited in all areas except the vehicle access bay. MECHANICAL-ACCESS OPEN PARKING GARAGES. Open parking garages employing parking machines, lifts, elevators or other mechanical devices for vehicles moving from and to street level and in which public occupancy is prohibited above the street level. MECHANICAL EQUIPMENT SCREEN. A rooftop structure, not covered by a roof, used to aesthetically conceal plumbing, electrical or mechanical equipment from view. METAL COMPOSITE MATERIAL (MCM). A factorymanufactured panel consisting of metal skins bonded to both faces of a solid plastic core. [BS] METAL ROOF PANEL. An interlocking metal sheet having a minimum installed weather exposure of 3 square feet (0.279 m2) per sheet. [BS] METAL ROOF SHINGLE. An interlocking metal sheet having an installed weather exposure less than 3 square feet (0.279 m2) per sheet. [RB] METAL ROOF PANEL, METAL ROOF SHINGLE MANUFACTURER. The party responsible that forms raw material into metal roof panels and/or metal roof shingles used in building construction. MEZZANINE. An intermediate level or levels between the floor and ceiling of any story and in accordance with Section 505. [BS] MICROPILE. A micropile is a bored, grouted-in-place deep foundation element that develops its load-carrying capacity by means of a bond zone in soil, bedrock or a combination of soil and bedrock. MEDICAL CARE. Care involving medical or surgical procedures, nursing or for psychiatric purposes. MEMBRANE-COVERED CABLE STRUCTURE. A nonpressurized structure in which a mast and cable system provides support and tension to the membrane weather barrier and the membrane imparts stability to the structure. MINERAL BOARD. A rigid felted thermal insulation board consisting of either felted mineral fiber or cellular beads of expanded aggregate formed into flat rectangular units. MEMBRANE-COVERED FRAME STRUCTURE. A nonpressurized building wherein the structure is composed of MINERAL WOOL. Synthetic vitreous fiber insulation made by melting predominately igneous rock or furnace slag, 42 MINERAL FIBER. Insulation composed principally of fibers manufactured from rock, slag or glass, with or without binders. FLORIDA BUILDING CODE — BUILDING, 8th EDITION (2023) Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 DEFINITIONS and other inorganic materials, and then physically forming the melt into fibers. [BS] MODIFIED BITUMEN ROOF COVERING. One or more layers of polymer-modified asphalt sheets. The sheet materials shall be fully adhered or mechanically attached to the substrate or held in place with an approved ballast layer. [BS] MORTAR. A mixture consisting of cementitious materials, fine aggregates, water, with or without admixtures, that is used to construct unit masonry assemblies. [BS] MORTAR, SURFACE-BONDING. A mixture to bond concrete masonry units that contains hydraulic cement, glass fiber reinforcement with or without inorganic fillers or organic modifiers and water. MULTILEVEL ASSEMBLY SEATING. Seating that is arranged in distinct levels where each level is comprised of either multiple rows, or a single row of box seats accessed from a separate level. [F] MULTIPLE-STATION ALARM DEVICE. Two or more single-station alarm devices that can be interconnected such that actuation of one causes all integral or separate audible alarms to operate. A multiple-station alarm device can consist of one single-station alarm device having connections to other detectors or to a manual fire alarm box. [F] MULTIPLE-STATION SMOKE ALARM. Two or more single-station alarm devices that are capable of interconnection such that actuation of one causes the appropriate alarm signal to operate in all interconnected alarms. MULTISTORY UNIT. A dwelling unit or sleeping unit with habitable space located on more than one story. [BF] NAILABLE SUBSTRATE. A product or material such as framing, sheathing or furring, composed of wood, wood-based materials or other materials providing equivalent fastener withdrawal resistance. [BS] NOMINAL LOADS. The magnitudes of the loads specified in Chapter 16 (dead, live, soil, wind, tornadoes, rain, and flood ). [BS] NOMINAL SIZE (LUMBER). The commercial size designation of width and depth, in standard sawn lumber and glued-laminated lumber grades; somewhat larger than the standard net size of dressed lumber, in accordance with DOCPS 20 for sawn lumber and with the ANSI/AWC NDS for glued-laminated lumber. NONCOMBUSTIBLE MEMBRANE STRUCTURE. A membrane structure in which the membrane and all component parts of the structure are noncombustible. [BS] NONSTRUCTURAL CONCRETE. Any element made of plain or reinforced concrete that is not part of a structural system required to transfer either gravity or lateral loads to the ground. NONVISITATION CRYPT MAUSOLEUM. A mausoleum for the public where the crypts are not accessible to the public. [F] NORMAL TEMPERATURE AND PRESSURE (NTP). A temperature of 70°F (21°C) and a pressure of 1 atmosphere [14.7 psia (101 kPa)]. NOSING. The leading edge of treads of stairs and of landings at the top of stairway flights. NOTIFICATION ZONE. See “Zone, notification.” [F] NUISANCE ALARM. An alarm caused by mechanical failure, malfunction, improper installation or lack of proper maintenance, or an alarm activated by a cause that cannot be determined. NURSING HOMES. Facilities that provide care, including both intermediate care facilities and skilled nursing facilities where any of the persons are incapable of self-preservation. OCCUPANT LOAD. The number of persons for which the means of egress of a building or portion thereof is designed. [BS] NAILING, EDGE. A special nailing pattern required by design at the edges of each panel within the assembly of a diaphragm or shear wall. OCCUPIABLE SPACE. A room or enclosed space designed for human occupancy in which individuals congregate for amusement, educational or similar purposes or in which occupants are engaged at labor, and which is equipped with means of egress and light and ventilation facilities meeting the requirements of this code. [BS] NAILING, FIELD. Nailing required between the sheathing panels and framing members at locations other than boundary nailing and edge nailing. OPEN-AIR ASSEMBLY SEATING. Seating served by means of egress that is not subject to smoke accumulation within or under a structure and is open to the atmosphere. [BS] NATURALLY DURABLE WOOD. The heartwood of the following species except for the occasional piece with corner sapwood, provided 90 percent or more of the width of each side on which it occurs is heartwood. OPEN-ENDED CORRIDOR. An interior corridor that is open on each end and connects to an exterior stairway or ramp at each end with no intervening doors or separation from the corridor. Decay resistant. Redwood, cedar, black locust and black walnut. OPEN PARKING GARAGE. A structure or portion of a structure with the openings as described in Section 406.5.2 on two or more sides that is used for the parking or storage of private motor vehicles as described in Section 406.5.3. [BS] NAILING, BOUNDARY. A special nailing pattern required by design at the boundaries of diaphragms. Termite resistant. Redwood, Alaska yellow cedar, Eastern red cedar and Western red cedar. NICHE. A permanent chamber in a columbarium or mausoleum to hold the cremated remains of one or more individuals. FLORIDA BUILDING CODE — BUILDING, 8th EDITION (2023) [F] OPEN SYSTEM. The use of a solid or liquid hazardous material involving a vessel or system that is continuously open to the atmosphere during normal operations and where vapors are liberated, or the product is exposed to the atmo43 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 DEFINITIONS sphere during normal operations. Examples of open systems for solids and liquids include dispensing from or into open beakers or containers, dip tank and plating tank operations. [F] OPERATING BUILDING. A building occupied in conjunction with the manufacture, transportation or use of explosive materials. Operating buildings are separated from one another with the use of intraplant or intraline distances. [BS] ORDINARY PRECAST STRUCTURAL WALL. See Section 1905.1.1. [BS] ORDINARY REINFORCED CONCRETE STRUCTURAL WALL. See Section 1905.1.1. [BS] ORDINARY STRUCTURAL PLAIN CONCRETE WALL. See Section 1905.1.1. [F] ORGANIC PEROXIDE. An organic compound that contains the bivalent -O-O- structure and which may be considered to be a structural derivative of hydrogen peroxide where one or both of the hydrogen atoms have been replaced by an organic radical. Organic peroxides can pose an explosion hazard (detonation or deflagration) or they can be shock sensitive. They can also decompose into various unstable compounds over an extended period of time. Class I. Those formulations that are capable of deflagration but not detonation. Class II. Those formulations that burn very rapidly and that pose a moderate reactivity hazard. Class III. Those formulations that burn rapidly and that pose a moderate reactivity hazard. Class IV. Those formulations that burn in the same manner as ordinary combustibles and that pose a minimal reactivity hazard. Class V. Those formulations that burn with less intensity than ordinary combustibles or do not sustain combustion and that pose no reactivity hazard. Unclassified detonable. Organic peroxides that are capable of detonation. These peroxides pose an extremely high explosion hazard through rapid explosive decomposition. [BS] ORTHOGONAL. To be in two horizontal directions, at 90 degrees (1.57 rad) to each other. [BS] OTHER STRUCTURES (for Chapters 16-23). Structures, other than buildings, for which loads are specified in Chapter 16. OUTPATIENT CLINIC. See “Clinic, outpatient.” [A] OWNER. Any person, agent, operator, entity, firm or corporation having any legal or equitable interest in the property; or recorded in the official records of the state, county or municipality as holding an interest or title to the property; or otherwise having possession or control of the property, including the guardian of the estate of any such person, and the executor or administrator of the estate of such person if ordered to take possession of real property by a court. [F] OXIDIZER. A material that readily yields oxygen or other oxidizing gas, or that readily reacts to promote or initiate combustion of combustible materials and, if heated or 44 contaminated, can result in vigorous self-sustained decomposition. Class 4. An oxidizer that can undergo an explosive reaction due to contamination or exposure to thermal or physical shock and that causes a severe increase in the burning rate of combustible materials with which it comes into contact. Additionally, the oxidizer causes a severe increase in the burning rate and can cause spontaneous ignition of combustibles. Class 3. An oxidizer that causes a severe increase in the burning rate of combustible materials with which it comes in contact. Class 2. An oxidizer that will cause a moderate increase in the burning rate of combustible materials with which it comes in contact. Class 1. An oxidizer that does not moderately increase the burning rate of combustible materials. [F] OXIDIZING GAS. A gas that can support and accelerate combustion of other materials more than air does. [BS] PANEL (PART OF A STRUCTURE). The section of a floor, wall or roof comprised between the supporting frame of two adjacent rows of columns and girders or column bands of floor or roof construction. PANIC HARDWARE. A door-latching assembly incorporating a device that releases the latch upon the application of a force in the direction of egress travel. See “Fire exit hardware.” [BS] PARTICLEBOARD. A generic term for a panel primarily composed of cellulosic materials (usually wood), generally in the form of discrete pieces or particles, as distinguished from fibers. The cellulosic material is combined with synthetic resin or other suitable bonding system by a process in which the interparticle bond is created by the bonding system under heat and pressure. PEDESTAL. A fixed or adjustable-height support column composed of a support base, a vertical structural element and a load-bearing top cap surface. PEDESTRIAN DECK PANELS OR PAVERS. Pedestrian deck panels or pavers for this section are manufactured from materials such as naturally durable wood, ceramic, stone or concrete suitable for exterior applications. PENETRATION FIRESTOP. A through-penetration firestop or a membrane-penetration firestop. PENTHOUSE. An enclosed, unoccupied rooftop structure used for sheltering mechanical and electrical equipment, tanks, elevators and related machinery, and vertical shaft openings. [BS] PERFORMANCE CATEGORY. A designation of wood structural panels as related to the panel performance used in Chapter 23. PERMANENT INDIVIDUAL TRUSS MEMBER DIAGONAL BRACING (PITMDB). Structural member or assembly intended to permanently stabilize the PITMRs. PERMANENT INDIVIDUAL TRUSS MEMBER RESTRAINT (PITMR). Restraint that is used to prevent FLORIDA BUILDING CODE — BUILDING, 8th EDITION (2023) Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER. 101674064 DEFINITIONS local buckling of an individual truss chord or web member because of the axial forces in the individual truss member. [A] PERMIT. An official document or certificate issued by the building official that authorizes performance of a specified activity. [A] PERSON. An individual, heirs, executors, administrators or assigns, and also includes a firm, partnership or corporation, its or their successors or assigns, or the agent of any of the aforesaid. PERSONAL CARE SERVICE. The care of persons who do not require medical care. Personal care involves responsibility for the safety of the persons while inside the building PHOTOLUMINESCENT. Having the property of emitting light that continues for a length of time after excitation by visible or invisible light has been removed. PHOTOVOLTAIC MODULE. A complete, environmentally protected unit consisting of solar cells, optics and other components, exclusive of tracker, designed to generate DC power when exposed to sunlight. PHOTOVOLTAIC PANEL. A collection of modules mechanically fastened together, wired and designed to provide a field-installable unit. PHOTOVOLTAIC PANEL SYSTEM. A system that incorporates discrete photovoltaic panels, that converts solar radiation into electricity, including rack support systems. PHOTOVOLTAIC SHINGLES. A roof covering resembling shingles that incorporates photovoltaic modules. [F] PHYSICAL HAZARD. A chemical for which there is evidence that it is a combustible liquid, cryogenic fluid, explosive, flammable (solid, liquid or gas), organic peroxide (solid or liquid), oxidizer (solid or liquid), oxidizing gas, pyrophoric (solid, liquid or gas), unstable (reactive) material (solid, liquid or gas) or water-reactive material (solid or liquid). [F] PHYSIOLOGICAL WARNING THRESHOLD LEVEL. A concentration of airborne contaminants, normally expressed in parts per million (ppm) or milligrams per cubic meter (mg/m3), that represents the concentration at which persons can sense the presence of the contaminant due to odor, irritation or other quick-acting physiological response. When used in conjunction with the permissible exposure limit (PEL) the physiological warning threshold levels are those consistent with the classification system used to establish the PEL. See the definition of “Permissible exposure limit (PEL)” in the Florida Fire Prevention Code. PLACE OF RELIGIOUS WORSHIP. See “Religious worship, place of.” PLANS. All construction drawings and specifications for any structure necessary for the building official to review in order to determine whether a proposed structure, addition or renovation will meet the requirements of this code and other applicable codes. PLASTIC, APPROVED. Any thermoplastic, thermosetting or reinforced thermosetting plastic material that conforms to combustibility classifications specified in the section applicable to the application and plastic type. FLORIDA BUILDING CODE — BUILDING, 8th EDITION (2023) PLASTIC COMPOSITE. A generic designation that refers to wood/plastic composites, plastic lumber and similar materials. PLASTIC GLAZING. Plastic materials that are glazed or set in frame or sash and not held by mechanical fasteners that pass through the glazing material. PLASTIC LUMBER. A manufactured product made primarily of plastic materials (filled or unfilled) which is generally rectangular in cross section. PLATFORM. A raised area within a building used for worship, the presentation of music, plays or other entertainment; the head table for special guests; the raised area for lecturers and speakers; boxing and wrestling rings; theater-in-theround stages; and similar purposes wherein, other than horizontal sliding curtains, there are no overhead hanging curtains, drops, scenery or stage effects other than lighting and sound. A temporary platform is one installed for not more than 30 days. PLAY STRUCTURE. A structure composed of one or more components, where the user enters a play environment. POLYPROPYLENE SIDING. A shaped material, made principally from polypropylene homopolymer, or copolymer, which in some cases contains fillers or reinforcements, that is used to clad exterior walls of buildings. [BS] PORCELAIN TILE. Ceramic tile having an absorption of 0.5 percent or less in accordance with ANSI A137.1, Table 10 or ANSI A137.3, Tables 4 or 5. [BS] POSITIVE ROOF DRAINAGE. The drainage condition in which consideration has been made for all loading deflections of the roof deck, and sufficient slope has been provided to ensure drainage of the roof within 48 hours of precipitation. POWER-ASSISTED DOOR. Swinging door which opens by reduced pushing or pulling force on the door-operating hardware. The door closes automatically after the pushing or pulling force is released and functions with decreased forces. See “Low-energy power-operated door” and “Power-operated door.” POWER-OPERATED DOOR. Swinging, sliding, or folding door which opens automatically when approached by a pedestrian or opens automatically upon an action by a pedestrian. The door closes automatically and includes provisions such as presence sensors to prevent entrapment. See “Lowenergy power-operated door” and “Power-assisted door.” [BS] PREFABRICATED WOOD I-JOIST. Structural member manufactured using sawn or structural composite lumber flanges and wood structural panel webs bonded together with exterior exposure adhesives, which forms an “I” cross-sectional shape. [BS] PRESTRESSED MASONRY. Masonry in which internal stresses have been introduced to counteract potential tensile stresses in masonry resulting from applied loads. PRIMARY STRUCTURAL FRAME. The primary structural frame shall include all of the following structural members: 1. The columns. 45 Copyright © 2023 ICC. ALL RIGHTS RESERVED. Accessed by Linda Benedetti (wja@wjarc.com), (-) Order Number #101674064 on Jan 02, 2024 10:55 AM (CST) pursuant to License Agreement with ICC. No further reproduction, no further reproductions by any third party, or distribut
0
You can add this document to your study collection(s)
Sign in Available only to authorized usersYou can add this document to your saved list
Sign in Available only to authorized users(For complaints, use another form )