INDUSTRIAL MEDIUM VOLTAGE CABLES
RE4H1(O)RFR (XLPE/CTS/PVC/SWA/PVC)
Construction:
Conductor:
Resistance:
stranded red copper conductor Cl.2,
acc.to IEC 60228
Inner
semi-conductive
layer:
extruded semi-conducting compound
Insulation:
XLPE compound
Outer
semi-conductive
layer:
extruded semi-conducting compound
Screen:
red copper tape
Inner sheath:
PVC compound
Armour:
steel wires
Outer sheath:
red (RAL 3000), PVC type ST2
Flame retardant acc. to:
DIN VDE 0482 part 265-2-1
EN 50265-2-1
IEC 60332-1
Features:
Technical data:
Nominal voltage:
Uo/U 3,6/6 kV, Uo/U 6/10 kV
Uo/U 8,7/15 kV, Uo/U 12/20 kV,
Uo/U 18/30 kV
Test voltage:
Uo/U 3,6/6 kV = 11 kV
Uo/U 6/10 kV = 17 kV
Uo/U 8,7/15 kV = 24 kV
Uo/U 12/20 kV= 29 kV
Uo/U 18/30 kV = 45 kV
Max. operating
voltage:
according to IEC 60502-2
Uo/U 3,6/6 kV = Um 7,2 kV
Uo/U 6/10 kV = Um 12 kV
Uo/U 8,7/15 kV = Um 17,5 kV
Uo/U 12/20 kV = Um 24 kV
Uo/U 18/30 kV = Um 36 kV
Temperature range:
0 oC up to + 90 oC
Max short circuit
temperature:
+ 250 oC
Min. bending radius:
14 x d
3,6/6 kV (Um 7,2 kV)
Part no.
No.of cores
x cross section
n x mm2
Outer-Ø
ca.mm
± 10%
Cable
weight approx.
kg/km
AWG
no.*)
48110MR1030M64
48110MR1030M65
48110MR1030M66
48110MR1030M67
48110MR1030M68
48110MR1030M69
48110MR1030M70
48110MR1030M71
48110MR1030M72
3x35
3x50
3x70
3x95
3x120
3x150
3x185
3x240
3x300
44
48
52
55,5
59
62,5
66
73
81
4210
5300
6330
7590
8710
9920
11450
13620
17400
2
1
2/0
3/0
4/0
250 MCM
350 MCM
450 MCM
550 MCM
122
www.elettrotekkabel.com
INDUSTRIAL MEDIUM VOLTAGE CABLES
RE4H1(O)RFR (XLPE/CTS/PVC/SWA/PVC)
6/10 kV (Um 12 kV)
Part no.
No.of cores
x cross section
n x mm2
Outer-Ø
ca.mm
± 10%
Cable
weight approx.
kg/km
AWG
no.*)
48110QR1030M64
48110QR1030M65
48110QR1030M66
48110QR1030M67
48110QR1030M68
48110QR1030M69
48110QR1030M70
48110QR1030M71
3x35
3x50
3x70
3x95
3x120
3x150
3x185
3x240
49,5
52,3
56
60
63,5
67,3
70,5
78
5220
5940
6980
8290
9490
10790
11900
15300
2
1
2/0
3/0
4/0
250 MCM
350 MCM
450 MCM
Part no.
No.of cores
x cross section
n x mm2
Outer-Ø
ca.mm
± 10%
Cable
weight approx.
kg/km
AWG
no.*)
48110SR1030M64
48110SR1030M65
48110SR1030M66
48110SR1030M67
48110SR1030M68
48110SR1030M69
48110SR1030M70
3x35
3x50
3x70
3x95
3x120
3x150
3x185
52
54
58
62
66
70
74
3500
4000
4800
5900
6950
8000
9500
2
1
2/0
3/0
4/0
250 MCM
350 MCM
Part no.
No.of cores
x cross section
n x mm2
Outer-Ø
ca.mm
± 10%
Cable
weight approx.
kg/km
AWG
no.*)
48110UR1030M64
48110UR1030M65
48110UR1030M66
48110UR1030M67
48110UR1030M68
48110UR1030M69
48110UR1030M70
3x35
3x50
3x70
3x95
3x120
3x150
3x185
54
56,3
59,6
64
68
71,5
74,5
6790
7570
8720
9790
11830
13170
14900
2
1
2/0
3/0
4/0
250 MCM
350 MCM
Part no.
No.of cores
x cross section
n x mm2
Outer-Ø
ca.mm
± 10%
Cable
weight approx.
kg/km
AWG
no.*)
48110XR1030M65
48110XR1030M66
3x50
3x70
75,6
79,5
10290
11600
1
2/0
8,7/15 kV (Um 17,5 kV)
12/20 kV (Um 24 kV)
18/30 kV (Um 36 kV)
* For cables laying in earth a screen-cross section of 16 mm is permitted.
Other dimensions and colours available on request.
www.elettrotekkabel.com
123