Int J Adv Manuf Technol DOI 10.1007/s00170-016-8798-7 ORIGINAL ARTICLE Reduction of pulsed-laser surface irradiation induced residual stress using ultrasonic vibration method Bang-ping Gu 1,2,3 & Zi-di Jin 3,5 & De-jun Kong 2 & Jin-tao Lai 4 & Zhen-sheng Yang 1 & Long Pan 3 Received: 25 November 2015 / Accepted: 18 April 2016 # Springer-Verlag London 2016 Abstract The ultrasonic vibration method was introduced to relieve the residual stress in the small AISI 1045 steel specimen subjected to the pulsed-laser surface irradiation. The ultrasonic vibration plasticity framework was developed based on the thermal activation theory and the dislocation glide kinetics theory in order to reveal the double dynamic stress effect and the time effect of the ultrasonic stress relief. To validate the proposed model, the ultrasonic stress relief experiments were carried out using the AISI 1045 steel specimens treated by the pulsed-laser surface irradiation based on the Nd:YAG pulsedlaser machine. The results show that the ultrasonic stress relief has good effects on eliminating residual stress. Furthermore, the residual stress relaxation due to the double dynamic stress effect can be improved by increasing the ultrasonic vibration power and the initial magnitude of residual stress. The residual stress decrease due to the time effect can be improved by increasing the ultrasonic vibration time. The unified ultrasonic vibration plasticity model can accurately account the double dynamic stress effect and the time effect. The findings confirm * Bang-ping Gu 11025033@zju.edu.cn 1 College of Logistics Engineering, Shanghai Maritime University, Shanghai 201306, People’s Republic of China 2 School of Mechanical Engineering, Changzhou University, Changzhou 213164, People’s Republic of China 3 Zhejiang Province Key Laboratory of Advanced Manufacturing Technology, Zhejiang University, Hangzhou 310027, People’s Republic of China 4 Department of Mechanical and Electrical Engineering, Shaoxing University, Beijing 102628, People’s Republic of China 5 Beijing Geolight Technology Co., Ltd, Beijing 102628, People’s Republic of China that the ultrasonic stress relief can be used to eliminate residual stress in small workpieces and provide a basis to understand the underlying mechanism of the ultrasonic stress relief. Keywords Ultrasonic vibration . Crystal plasticity . Pulsed-laser . Residual stress . Microstructure . Time effect 1 Introduction The high-energy laser processing technology has been a widely used method for modifying the mechanical properties of the materials [1–4] since high-power laser beam can provide a controllable and precise energy source for the treated materials. According to the application of the high-energy laser processing technology, it can be concluded that the highenergy laser processing technology can be used to modify the mechanical properties of the workpiece in order to improve its service life. Although the high-energy laser processing technology has been widely used to modify the mechanical properties [1–4] of the treated materials, the larger tensile residual stresses and the distortions of the workpieces can be induced by the increasing temperature during the high-energy laser processing [5–8]. As a result, the application of this promising treatment process will be limited since the larger tensile residual stress decreases the service life of the workpieces. So how to eliminate the larger tensile residual stress induced by the high-energy laser processing technology has become an important topic in the research field of the highenergy laser processing technology, especially to eliminate the local larger tensile residual stress of the treated workpiece. At present, the residual stress relieving processes mainly includes the natural stress relief (NSR) process, the thermal stress relief (TSR) process [9], the vibratory stress relief (VSR) process [10–14], and the ultrasonic stress relief (USR) Int J Adv Manuf Technol process [15]. The NSR process belongs to the oldest stress relieving process, in which the treated workpieces was placed in the outdoor. The main drawbacks of the NSR process mainly include the poor effect, longer processing time, large space occupation, and so on. The TSR process belongs to the conditional stress relief method as well, in which the treated workpieces was placed in the annealing furnace to be heated up to the annealing temperature. And the workpieecs need to hold definite times at the annealing temperature followed by a desired rate of cooling. In this case, the residual stress in the workpieces can be eliminated by the TSR process. The main drawbacks of the TSR mainly include the longer processing time, large space occupation due to the larger volume of the annealing furnace, more investment owing to the higher cost of the annealing furnace, and so on. Considering the limitation of the NSR and TSR processes, the vibratory stress relief process at the resonant frequencies of the workpieces was introduced by McGoldrick and Saunders [10]. They claimed that the vibratory stress relief technology can decrease the residual stress of the workpieces. The most related research work of the vibratory stress relief technology was done by Walker et al. [11], in which a low-alloy steel EN3b specimen was excited with the vibration frequency of 100 Hz. They claimed that residual stress relaxation rate could reach as much as 40 %. The residual stress in the HT-7U Tokamak welded structure was relieved by means of the vibratory stress relief technology according to the studies presented by Rao et al. [12], in which the vibration frequency was 47.83 and 60.68 Hz. They found that average decrease value of the longitudinal residual stress could reach about 39.5 MPa. Sun et al. [13] relieved the residual stress in the marine shafting with the material of 35# bar steel by the vibratory stress relief process. The residual stress was evaluated by X-ray diffraction method and the macro residual stress decreased by about 48 %. Abrao et al. [14] relieved the residual stress in AISI 1060 steel by the means of cyclic loading. They claimed that the residual stress relaxation could be observed with an applied stress of 80 % of the yield strength. Among these different residual stress relief processes, the vibratory stress relief technology has become the most preferred method for decreasing the residual stresses of the workpieces owing to its advantages, which mainly includes the better processing effect, energy saving, short processing time, and environment protection. Even though the vibratory stress relief process has been extensively studied [10–14], the limitation of the vibratory stress relief process can be drawn as follows. The adjustable-speed motor was adopted as the exciter and the vibration frequency was lower than 200 Hz, which results in that the vibratory stress relief process is confined to eliminating the residual stress of the large workpieces. In addition, the small workpieces cannot be installed on the adjustable-speed motor, which results in that the residual stress in small workpieces cannot be effectively eliminated by the vibratory stress relief process. So the residual stress in the small workpieces cannot be effectively eliminated by the conventional vibratory stress relief process. Considering the limitation of the conventional vibratory stress relief process, the ultrasonic stress relief on stainless steel 316 specimens was introduced by Shalvandi et al. [15]. They found that the residual stress relaxation rate can even about 50 %, and this method was comparable with the conventional TSR process. The findings confirm that the ultrasonic stress relief process is promising to decrease the local residual stress of the workpieces. However, the mechanism of the ultrasonic stress relief process is still not clear. Most of all, the residual stress relaxation model of the conventional vibratory stress relief and the ultrasonic stress relief cannot reveal the relationship between the residual stress relaxation mechanism and the vibration time. Thus, the mechanism of the ultrasonic stress relief and the corresponding experimental studies of the ultrasonic stress relief must be carried out to promote the widely application of the ultrasonic stress relief process. In this study, the ultrasonic vibration plasticity framework was developed based on the thermal activation theory and the dislocation glide kinetics theory in order to reveal the double dynamic stress effect and the time effect of the ultrasonic stress relief. To validate the proposed model, the ultrasonic stress relief experiments were carried out using the AISI 1045 steel specimens treated by the pulsed-laser surface irradiation based on the Nd:YAG pulsed-laser machine. 2 Ultrasonic vibration plasticity framework 2.1 Modeling of residual stress relaxation based on thermal activation theory The shear plastic strain rate due to thermally activated dislocation glide along the slip plane is generally represented using the following equation based on the thermal activation theory, which can be given as [16, 17] −ΔG : p : γ ¼ γ 0 exp ; ð1Þ kBT : : where γ p is the shear plastic strain rate, γ 0 is the preexponential factor and can be regarded as a numerical constant, ΔG is the Gibbs free energy for overcoming an obstacle, kB is the Boltzmann constant, and T is the absolute temperature. A generalization equation of ΔG can be given as [16, 17] ! p #q " τ ΔG ¼ ΔF 1− ; ð2Þ τ^ where ΔF is the total free energy necessary to overcome an obstacle without the help of external applied dynamic stress; τ Int J Adv Manuf Technol is the shear stress produced by the external exciting and the internal initial residual stress, which is applied on the slip plane; the exponents p and q are the obstacle distribution parameters with the range of 0 < p ≤ 1 and 1 ≤ q ≤ 2; τ^ is called mechanical threshold representing the material property, which is regarded as the maximum resistance for dislocation glide along the slip plane. The mechanical threshold depends on the total dislocation density of the materials, which is usually given as [16, 17] pffiffiffi τ^ ¼ τ 0 þ αGb ρ; ð3Þ where ρ is the dislocation density, τ0 is the friction stress and is generated by the crystal lattice, α is a numerical constant, G is the shear modulus of the materials, and b is the magnitude of the Burgers vector. The dislocation density evolution governing equation can be given as [18–21] dρ pffiffiffi ¼ k 1 ρ−k 2 ρ; dγ p ð4Þ where k1 is dislocation storage coefficient representing the dislocation accumulation process and can be regarded as a numerical constant, and k2 is dynamic recovery coefficient representing the dislocation annihilation process and is affected by the plastic strain state and the temperature. The shear stress τ forcing the dislocation motion along the slip plane can be given as τ ¼ τ d þ τ r; ð5Þ where τd is the shear stress applied on the slip plane produced by the acoustic field, which is influenced by the ultrasonic vibration energy; and τr is the resolved value of the internal initial residual stress inside the materials, which is applied on the slip plane as well. In this case, the driving stress forcing the dislocation motion along the slip plane consists of the external dynamic stress applied on the slip plane and the resolved value of the initial residual stress inside the materials. From the view of the driving stress forcing the dislocation motion, the initial residual stress inside the materials can be regarded the dynamic stress as well [13], which is produced by the internal residual stress field. In other words, the driving stress forcing the dislocations motion can be regarded as “double dynamic stress.” When the sum of the double dynamic stress is larger than the mechanical threshold, the dislocations inside the materials will glide along the slip plane. In this case, the dislocations will be easily forced motion when the materials are exposed on the acoustic field and the internal residual stress field. And the shear plastic deformation will happen inside the materials according to the preceding Eq. (1), which results in that the elastic strain energy stored inside the materials will be released by means of plastic deformation. In other words, the residual stress inside the materials can be eliminated by the ultrasonic stress relief owing to the “double dynamic stress effect.” According to the studies presented by Shalvandi et al. [15], it can be concluded that the acoustic softening effect will occur in the polycrystalline material during the ultrasonic stress relief process, which implies that the mechanical threshold can be reduced with the help of the acoustic field. Shalvandi et al. [15] claimed that the acoustic softening effect could be attributed to the temperature effect. We also find the temperature increased significantly during the experimental process of the ultrasonic stress relief. Based on the Eq. (3), it can be concluded that the mechanical threshold is strongly related to the dislocation density during the plastic deformation process. In these cases, it can be concluded that the ultrasonic vibration energy can be easily absorbed by the dislocations, which results in that the dislocation annihilation process has a dominant position than the dislocation accumulation process during the ultrasonic stress relief process. So the dislocation density evolution governing equation can be further given as dρ pffiffiffi ¼ k 1 ρ−k 2 ð1 þ κÞρ; dγ p ð6Þ where κ represents the change ratio of the dynamic recovery coefficient with the help of the acoustic field. In this case, the mechanical threshold for the dislocation motion will decrease based on the Eq. (3), which is beneficial to promote the dislocation motion and thus the residual stress in the specimen can be easily eliminated by the ultrasonic stress relief process. From the view of the driving stress forcing the dislocation motion, the reduced mechanical threshold owing to the acoustic softening effect can be regarded as the increasing of the dynamic stress. Given the above, it can be found that the effect of the ultrasonic stress relief can be improved by increasing the ultrasonic vibration energy and the initial magnitude of residual stress based on the Eqs. (1)–(6). Maybe, it can be concluded that the effect of the ultrasonic stress relief has nothing to do with the ultrasonic vibration time. However, we can find the effect of the ultrasonic stress relief is strongly related to the ultrasonic vibration time according to the studies presented by Shalvandi et al. [15]. The modeling of dislocation motion velocity will be developed as shown in Section 2.2 in order to reveal the time effect of the ultrasonic stress relief. 2.2 Modeling of dislocation motion velocity based on dislocation glide kinetics theory The relationship between the ultrasonic vibration time and the effect of the ultrasonic stress relief can be revealed based on the modeling of dislocation motion velocity as follows. According to the studies presented by Fleischer [22] and Kocks et al. [16], the shear plastic strain rate induced by the dislocations motion can be expressed in the following two ways Int J Adv Manuf Technol : p γ ¼ bρv; −ΔG : p γ ¼ ρfbLexp ; kBT ð7Þ ð8Þ where v is the average velocity of a dislocation, f is the vibration frequency of a dislocation segment, and L is the length of a dislocation segment. Combining the preceding Eqs. (7) and (8), the average velocity of a dislocation can be given as −ΔG : ð9Þ v ¼ fLexp kBT According to the studies presented by Patra et al. [23], the average velocity of a dislocation can be derived as 8 !p !q ! > > τ < fLexp − Δ F 1− τ−^ ; forτ > τ^; ð10Þ v¼ kBT τt > > : 0; forτ ≤ τ^ where τt is the thermal lattice resistance for dislocation glide along the slip plane, typically governed by the high Peierls stress in bcc metallic materials [23]. Based on the Eq. (10), it can be concluded that the average motion velocity of a dislocation is zero when the double dynamic stress is not enough to overcome the maximum resistance for dislocation glide. In this case, the shear plastic deformation process will stop based on the preceding Eq. (7). As well known, the double dynamic stress during the ultrasonic stress relief is dynamically changing. The average motion velocity of a dislocation is more than zero only when the double dynamic stress is large enough to overcome the maximum resistance for dislocation glide based on the Eq. (10). And the shear plastic deformation process during the ultrasonic stress relief process can easily happen, which implies that the ultrasonic stress life has time effect. The shear plastic strain rate is, according to Eq. (7), proportional to the average motion velocity of a dislocation, which implies that the ultrasonic vibration plastic deformation is a “time-dependent” process. According to the studies presented by Kocks et al. [16] and Hiratani et al. [24], the average velocity of a dislocation can be further given as v¼ λ ; t run þ t wait ð11Þ where λ is the distance between two obstacles inside the materials, trun is the glide time of dislocation motion, and twait is the waiting time for the release of a dislocation from an obstacle with the help of the external mechanical loading. The glide time of dislocation motion between two obstacles inside the materials has been limited by the phonon drag, which can be expressed as [25] sffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffi ffi B 1 ; þ t run ¼ L τb vt ð12Þ where B is the drag coefficient per unit length of a dislocation [16] and vt is the transverse sound speed [25]. The waiting time can be given as [25] 0 1 τ^−τ ΔV A; t wait ¼ Δt 0 exp@ ð13Þ k BT where Δt0 is duration time of an attempt for depinning and ΔV is activation volume. The ultrasonic vibration plastic deformation is a “time-dependent” process based on the Eqs. (7)–(13). According to the studies presented by Kocks et al. [16], it can be found that the dislocation motion is jerky glide, the glide time is small compared with the waiting time, and the mobile dislocations inside the materials are waiting for activation rather than running [16], which implies that the ultrasonic stress relief is a “time-dependent” process as well. So increasing the ultrasonic vibration time can improve the effect of the ultrasonic stress relief. The corresponding experimental studies were carried out in order to verify the conclusions obtained from the modeling of residual stress relaxation based on thermal activation theory and the modeling of dislocation motion velocity based on dislocation glide kinetics theory as shown in Sections 3 and 4. 3 Materials and experimental methods 3.1 Materials The hot rolled AISI 1045 steel was used in this experimental investigation, whose chemical composition is given in Table 1. In order to study the effectiveness of the ultrasonic stress relief on small workpieces, many small AISI 1045 steel specimens were prepared from AISI 1045 steel sheet using fine electrodischarge wire cutting process. The dimension of a small AISI 1045 steel specimen is 60 mm × 20 mm × 3 mm as shown in Fig. 1. 3.2 Pulsed-laser surface irradiation induced residual stress The experimental setup for the pulsed-laser surface irradiation used in this study is shown in Fig. 2. This experimental system Table 1 Chemical composition of AISI 1045 steel used in this experimental investigation (wt%) Element C Si Mn Ni Fe Wt% 0.452 0.271 0.442 0.021 Remain Int J Adv Manuf Technol 3.3 Evaluation of residual stress using hole-drilling strain gage method Fig. 1 Dimension of a small AISI 1045 steel specimen mainly includes a pulsed-laser machine control cabinet, a motion control computer, a pulsed-laser source, and a working platform. The pulsed-laser machine control cabinet is used to control the pulse duration time and pulse frequency, in which the range of the pulse duration time is 0.5–6 ms, while the pulse frequency ranges from 1 to 50 Hz. The motion control computer is used to control the motion velocity of the working platform. The pulsed-laser source is used to output the highenergy pulsed-laser beam. The pulsed-laser surface irradiation experiments were performed based on an Nd:YAG pulsedlaser machine with the wavelength of 1.07 μm, in which the small AISI 1045 steel specimens were fixed on the working platform to be treated by the high-energy pulsed-laser beam. The high-energy pulsed-laser beam was focused on the specimen local surface with the help of an integrating mirror optic. In this case, the temperature in the laser-specimen interaction area is high induced by the high-energy pulsed-laser beam, which results in that the larger tensile residual stress would occur in the small specimen induced by phase-transformationinduced microstructure change [26]. The various small specimens with different initial residual stresses could be prepared by changing the pulse duration time, the pulse frequency, and the motion velocity. In this study, two groups of small specimens were prepared, in which the initial residual stress of the small specimens in the same group is assumed as the same. Fig. 2 Experimental setup for the pulsed-laser surface irradiation In order to evaluate the effect of the pulsed-laser surface irradiation-induced residual stress relaxation subjected to ultrasonic vibration load, the hole-drilling strain gage method [27] was used in this study. The schematic of a typical threeelement clockwise rosette used for measuring plane residual stress in this study is shown in Fig. 3 [27]. As shown in Fig. 3, D is the diameter of the gage circle and D0 is the diameter of the drilled hole. It can be found form Fig. 3 that the strain grid 1 and the strain grid 3 respectively coincide with the x-axis and the y-axis, while the angle between the strain grid 2 and the x-axis is 45°. σ1 and σ2 are, respectively, the first principal stress and the second principal stress and β is the angle between the x-axis and the first principal stress. During the testing process of the hole-drilling strain gage method [27], the residual stress inside the small specimen surrounding the drilled hole would be partially relieved when a hole was drilled in the surface layer of a small specimen. And the corresponding relieved strains around the drilled hole would be perceived by the three-element clockwise rosette shown in Fig. 3 and would be measured by a strainmeter. Figure 4 shows the case in which the residual stresses in the small specimen are uniform along its depth direction [27]. Assuming the residual stress distribution along the thickness direction of the small specimen is uniform or the residual stress gradient along the thickness direction of the small specimen is very small and can be ignored, the corresponding relieved strain surrounding the drilled hole can be given as [27] ε¼ 1 þ ν σx þ σ y 1 1 σx −σy þ bτ xy sin2θ þ b cos2θ; a 2 2 E E E ð14Þ Int J Adv Manuf Technol By solving the above-mentioned matrix Eq. (15), the xaxial residual stress σx, the y-axial residual stress σy and the shear xy-plane residual stress τxy can be given as the following matrix equation 2 6 3 6 6 σx 6 4 τ xy 5 ¼ 6 6 6 σy 6 4 2 E 2að1 þ ν Þ E þ 0 2b 2b E ! E E ! − 2að1 þ ν Þ 2b − E E E !3 7 72 3 7 ε1 7 74 ε2 5; 7 !7 7 ε3 E 5 2að1 þ ν Þ 2b E 2b b 0 − E 2að1 þ ν Þ þ 2b ð16Þ Fig. 3 Schematic of a typical three-element clockwise rosette for measuring plane residual stress [27] where ε is the relieved strain, ν is the Poisson’s ratio, E is the Yong’s modulus of the materials, ā is the calibration constant for isotropic stresses, b is the calibration constant for shear stresses, σx and σy are, respectively, the x-axial residual stress and the y-axial stress, τxy is the shear xy-plane residual stress, and θ is the anticlockwise angle of strain gage from the x-axis. In this study, the angles θ for the relieved strains ε1, ε2, and ε3 are, respectively, 0°, 135°, and 270° as shown in Fig. 3. Substituting the three anticlockwise angles θ into the preceding relieved strain Eq. (14), the relationship between σx, σy, τxy and ε1, ε2, ε3 can be given by the following matrix equation 2 að1 þ ν Þ b 6 þ 6 2E 2E 6 6 að1 þ ν Þ 6 6 2E 6 4 að1 þ ν Þ b − 2E 2E 0 − b E 0 3 að1 þ ν Þ b 72 − 3 2 3 2E 2E 7 ε1 7 σx að1 þ ν Þ 7 74 τ xy 5 ¼ 4 ε2 5; ð15Þ 7 2E ε3 7 σy að1 þ ν Þ b 5 þ 2E 2E So the x-axial residual stress σx and y-axial residual stress σy can be obtained according to the Standard ASTM E 837-08 [27]. ! ! 8 > E E E E > > σx ¼ þ − ε1 þ ε3 > < 2ð1 þ ν Þa 2b! 2ð1 þ ν Þa 2b ! : > E E E E > > > − þ ε1 þ ε3 : σy ¼ 2ð1 þ ν Þa 2b 2ð1 þ ν Þa 2b ð17Þ Figure 5 is the schematic of measured point for residual stress and attached strain rosette on the pulsed-laser surface irradiation area. The experimental setup for measuring residual stress mainly includes a ZDL-II residual stress measuring setup, a YE2538 static strainmeter capable of measuring three relieved strains in three different directions, and a TJ120-1.5-ϕ 1.5 strain rosette. The diameter of the drilled hole and the depth of the drilled hole are both 2 mm. According to Standard ASTM E 837-08 [27], the calibration constant for isotropic stresses ā and the calibration constant for shear stresses b are, respectively, selected as 0.192 and 0.482. 3.4 Ultrasonic stress relief In order to investigate the effect of the ultrasonic vibration load on small AISI 1045 steel specimens, the special experimental system for the ultrasonic stress relief was established as shown in Fig. 6. This system mainly includes an ultrasonic Fig. 4 Schematic for uniform residual stress measuring [27] Fig. 5 Schematic of measured point for residual stress and attached strain rosette Int J Adv Manuf Technol Fig. 6 Experimental system for the ultrasonic stress relief generator, an ultrasonic transducer, an ultrasonic horn, and a specially designed steel die. The ultrasonic generator is used to generate high-power electric pulses. The ultrasonic transducer is used to generate ultrasonic vibration, while the ultrasonic horn is used to amplify the ultrasonic vibration. A specially designed steel die is used to install the small AISI 1045 steel specimens. The ultrasonic transducer is mainly composed of a backing part, a piezoelectric used to transfer the high-power electric pulses into the ultrasonic vibration, and a matching part. The ultrasonic horn used in this system is made of the high-strength aluminum and is used to transfer the highpower ultrasonic vibration energy into the small AISI 1045 steel specimens to promote the dislocation motion inside the materials. The ultrasonic stress relief on the small AISI 1045 steel specimens was carried out using a JY92-IIDN probe ultrasonic processor with the highest power of 900 W and the frequency of 20 kHz. In the experimental studies of the ultrasonic stress relief, the different kinds of the ultrasonic vibration power and the ultrasonic vibration time were imposed on the small AISI 1045 steel specimens in order to study the effect of the ultrasonic vibration power and the ultrasonic vibration time on residual stress relaxation rate. In order to improve the reliability of the experimental results, three small specimens were randomly selected to evaluate the initial residual stresses in the same group of the small specimens by the holedrilling strain gage method before the ultrasonic stress relief. And the average residual stress value of the three small specimens were calculated and was regarded as the initial residual stress value of the same group of the small specimens treated by the same pulsed-laser surface irradiation parameters. And the three small specimens were treated using the same ultrasonic stress relief process parameters, and the residual stress in the three small specimens after the ultrasonic stress relief was evaluated by the holedrilling strain gage method as well. The average residual stress value of the three small specimens was calculated and was regarded as the residual stress value of the three small specimens treated by the same ultrasonic stress relief process parameters. 4 Results and discussions 4.1 Residual stress Figure 7 shows the initial residual stress of small specimens in the first group. It can be found from Fig. 7 that the average xaxial and y-axial residual stress are, respectively, 265 MPa and 233 MPa, which are regard as the initial x-axial and y-axial residual stress of small specimens in the first group. The experimental studies of the ultrasonic stress relief in order to reveal the effects of the ultrasonic vibration power and the ultrasonic vibration time on residual stress relaxation rate are carried out based on the first group of the small specimens. Figure 8 shows the effect of the ultrasonic vibration power on residual stress relaxation rate. It can be found from Fig. 8 that the largest x-axial and y-axial residual stress relaxation values are, respectively, 149 MPa and 124 MPa. In this case, the most x-axial and y-axial residual stress relaxation rate can reach 56.23 % and 53.22 %, which implies that the residual stress in small specimens can be eliminated by the ultrasonic stress relief. Furthermore, the effect of the ultrasonic stress relief can be improved with higher ultrasonic vibration power Fig. 7 Initial residual stress of small specimens in the first group Int J Adv Manuf Technol Fig. 8 The effect of the ultrasonic vibration power on residual stress relaxation rate: (a) x axial residual stress; (b) y axial residual stress (Ultrasonic vibration time is 15 min) as shown in Fig. 8. The shear stress τd can be increased with higher ultrasonic vibration power. In this case, the dislocation motion along the slip plane can be easily achieved based on the double dynamic stress effect, which results in that the shear plastic deformation can easily happen with the increasing shear stress τd. Moreover, the mechanical threshold for the dislocation motion can be decreased owing to the acoustic softening effect with the help of the acoustic field. In this case, the dislocation motion along the slip plane can be easily achieved based on the acoustic softening effect, which results in that the shear plastic deformation can easily happen with the decreasing mechanical threshold. As a result, the residual stress relaxation rate can be improved with higher ultrasonic vibration power as shown in Fig. 8. Figure 9 shows the effect of the ultrasonic vibration time on residual stress relaxation rate. It can be found from Fig. 9 that the effect of the ultrasonic stress relief can be improved by increasing the ultrasonic vibration time. Based on the Eqs. (7)–(13), it can be concluded that the ultrasonic stress relief is a “time-dependent” process, which implies that the residual stress relaxation rate is different with different ultrasonic time as shown in Fig. 9. According to the studies presented by Kocks et al. [16], the glide time is small compared with the waiting time and the mobile dislocations inside the materials are waiting for activation rather than running, which implies that the residual stress relaxation process need some Fig. 9 The effect of the ultrasonic vibration time on residual stress relaxation rate: (a) x axial residual stress; (b) y axial residual stress (Ultrasonic vibration power is 800 W) time to complete. So increasing the ultrasonic vibration time can improve the residual stress relaxation rate. Figure 10 shows the initial residual stress of small specimens in the second group. It can be found from Fig. 10 that the average x-axial and y-axial residual stress are, respectively, 216 MPa and 179 MPa, which are regard as the initial x-axial and y-axial residual stress of small specimens in the second group. Figure 11 shows the effect of the initial magnitude of residual stress on residual stress relaxation rate (ultrasonic vibration power is 800 W and ultrasonic vibration time is 15 min). It can be found from Fig. 11 that the effect of the ultrasonic stress relief can be improved with higher initial residual stress. The initial residual stress can be regarded as the dynamic stress as analyzed in Section 2.1. As a result, increasing the initial magnitude of residual stress can improve the effect of the ultrasonic stress relief based on the double dynamic stress effect. So combining Figs. 8 and 11, it can be concluded that the effect of the ultrasonic stress relief can be improved by increasing the ultrasonic vibration power and the initial magnitude of the residual stress based on the double dynamic stress effect. According to the studies presented by Rao et al. [12], it can be found that the effect of residual stress relaxation due to the cyclic loading is mainly affected by (1) initial magnitude and gradient of the residual stress, (2) dynamic stress amplitude, and (3) vibration time. Thus, increasing the ultrasonic Int J Adv Manuf Technol Fig. 10 Initial residual stress of small specimens in the second group vibration time can improve the effect of the ultrasonic stress relief. The findings also explain why increasing the ultrasonic vibration power, the ultrasonic vibration time, and the initial magnitude of residual stress can improve the effect of the ultrasonic stress relief. 4.2 Evolution of microstructure during ultrasonic stress relief According to our previous studies [28], the microstructures before and after the pulsed-laser processing are analyzed by the LEICA DM6000 optical microscope (OM). The microstructure for the AISI 1045 steel comprises two phases of ferrite (F) and pearlite (P) before the pulsed-laser processing. And the microstructure for the AISI 1045 steel is martensite after the pulsed-laser processing. In order to better obtain the detail of the martensite, the scanning electron microscopy is used to analyze the microstructure. And Fig. 12 shows the SEM photos of a small AISI 1045 steel specimen before and after the ultrasonic stress relief in order to explain the residual stress relaxation mechanism of the ultrasonic stress relief. Figure 12(a) shows the microstructure of the specimen subjected to the pulsed-laser surface irradiation. It can be found from Fig. 12(a) that the microstructure is martensite, which implies that the larger tensile residual stress is induced by the phase-transformation-induced microstructure change. Figure 12(b) shows the microstructure of the specimen treated by the ultrasonic stress relief process. It can be found from Fig. 12(b) that the microstructure is martensite as well, which implies that the microstructure has not been changed by ultrasonic vibration. In this case, it can be concluded that the mechanism of the ultrasonic stress relief is not induced by the microstructure change. So the mechanism of the ultrasonic stress relief is the shear plastic deformation induced by the dislocation motion owing to the dynamic stress effect and the time effect as shown in Section 2. 5 Conclusions The ultrasonic vibration method was introduced to relieve the residual stress in the small AISI 1045 steel specimen subjected to the pulsed-laser surface irradiation. The ultrasonic vibration plasticity framework was developed based on the thermal activation theory and the dislocation glide kinetics theory in order to reveal the double dynamic stress effect and the time effect of the ultrasonic stress relief. To validate the proposed model, the ultrasonic stress relief experiments were carried out on AISI 1045 steel specimens. The main conclusions can be drawn as follows: & & & & Fig. 11 The effect of the initial residual stress on residual stress relaxation rate (ultrasonic vibration power is 800 W; ultrasonic vibration time is 15 min; BUV denotes before ultrasonic vibration, AUV denotes after ultrasonic vibration, and RS denotes residual stress) The double dynamic stress effect is modeled based on the thermal activation theory. It can be concluded that the mechanism of the ultrasonic stress relief can be attributed to the double dynamic stress effect, and increasing the ultrasonic vibration power and the initial magnitude of the residual stress can improve the effect of the ultrasonic stress relief. The time effect is modeled based on the dislocation glide kinetics theory. The ultrasonic stress relief is a “time-dependent” process, and increasing the ultrasonic vibration time can improve the effect of the ultrasonic stress relief. Residual stress measuring results show that the residual stress relaxation rate can be improved by increasing the ultrasonic vibration power, the ultrasonic vibration time, and the initial magnitude of the residual stress. The conclusions obtained from the experimental results agree well with the conclusions drawn from the modeling of residual stress relaxation and the modeling of dislocation motion velocity. SEM photos show there is no microstructure change of the specimen during the ultrasonic stress relief process. The only mechanism of the ultrasonic stress relief is the shear plastic deformation induced by the dislocation motion owing to the double dynamic stress effect and the time effect. Int J Adv Manuf Technol Fig. 12 SEM photos of small AISI 1045 steel specimen before and after the ultrasonic stress relief: (a) before ultrasonic vibration; (b) after ultrasonic vibration The unified ultrasonic vibration plasticity model is developed based on the crystal plasticity theory and can accurately account the dynamic stress effect and the time effect of the ultrasonic stress relief. The findings confirm that the ultrasonic stress relief can be used to eliminate the residual stress in small workpieces treated by high-energy laser processing technology and surface grinding process and provide a basis to understand the mechanism of the ultrasonic stress relief. Acknowledgments This research is sponsored by the Jiangsu Province Science and Technology Support Program (Industry) (BE2014818). 10. 11. 12. 13. 14. 15. References 16. 1. Saxena VK, Bharti A, Malakondaiah G, Radhakrishnan VM (1993) Effect of laser surface treatment on fatigue crack growth resistance in an Fe-Mn-Al austenitic. Int J Fatigue 5:369–375 2. Fernandez-Vicente A, Pellizzari M, Arias JL (2012) Feasibility of laser surface treatment of pearlitic and bainitic ductile irons for hot rolls. J Mater Process Technol 212:989–1002 3. Escudero ML, Bello JM (1992) Laser surface treatment and corrosion behaviour of martensitic stainless AISI 420 steel. Mater Sci Eng A 158:227–233 4. Razavi RS, Salehi M, Monirvaghefi M, Gordani GR (2008) Laser surface treatment of electroless Ni-Pcoatings on Al356 alloy. J Mater Process Technol 195:154–159 5. Eto S, Miura Y, Tani J, Fujii T (2014) Effect of residual stress induced by pulsed-laser irradiation on initiation of chloride stress corrosion cracking in stainless steel. Mater Sci Eng A 590:433–439 6. Chao Z, Wei T, Liang H (2013) A comprehensive study of thermal damage consequent to laser surface treatment. Mater Sci Eng A 546:381–388 7. Fang XY, Zhang JX (2014) Effect of underfill defects on distortion and tensile properties of Ti-2Al-1.5Mn welded joint by pulsed laser beam welding. Int J Adv Manuf Technol 74:699–705 8. Dai J, Liu Z, Yang L, Wang Y, Zhou CY, Zhang YC (2015) Research on pulsed laser welding of TiB2-enhanced aluminum matrix composites. Int J Adv Manuf Technol. doi:10.1007/ s00170-015-7887-3 9. Edwards P, Ramulu M (2015) Surface residual stress in Ti-6Al-4V friction stir welds: pre- and post-thermal stress relief. J Mater Eng Perform 24:3263–3270 17. 18. 19. 20. 21. 22. 23. 24. 25. McGolarick RT, Saunders HE (1943) Some experiments in stressrelieving casting and welded structures by vibration. J Am Soc Nav Eng 55:589–609 Walker CA, Waddell AJ, Johnston DJ (1995) Vibratory stress reliefan investigation of the underlying process. Proc Inst Mech Eng Part E: J Proc Mech Eng 209:51–58 Rao D, Wang D, Chen L, Ni C (2007) The effectiveness evaluation of 314L stainless steel vibratory stress relief by dynamic stress. Int J Fatigue 29:192–196 Sun MC, Sun YH, Wang RK (2004) The vibratory stress relief of a marine shafting of 35# bar steel. Mater Lett 58:299–303 Abrao AM, Denkena B, Kohler J, Breidenstein B, Morke T (2015) The inducement of residual stress through deep rolling of AISI 1060 steel and its subsequent relaxation under cyclic loading. Int J Adv Manuf Technol 79:1939–1947 Shalvandi M, Hojjat Y, Abdullah A, Asadi H (2013) Influence of ultrasonic stress relief on stainless steel 316 specimens: a comparison with thermal stress relief. Mater Des 46:713–723 Kocks UF, Argon AS, Ashby MF (1975) Thermodynamics and kinetics of slip, Progress in Materials Science. Pergamon Press, Oxford Kocks UF (1987) Constitutive behavior based on crystal plasticity. In: Miller AK (ed) Unified Constitutive Equations for Creep and Plasticity. Elsevier Applied Science, London; New York Kocks UF (1976) Laws for work-hardening and low-temperature creep. J Eng Mater Technol 98:76–85 Fang XF, Dahl W (1995) Strain hardening of steels at large strain deformation. Part I: relationship between strain hardening and microstructures of b.c.c. steels. Mater Sci Eng A 203:14–25 Estrin Y, Mecking H (1984) A unified phenomenological description of work hardening and creep based on one-parameter models. Acta Metall 32:57–70 Krausz AS, Krausz K (1996) Unified Plastic Constitutive Laws of Deformation. Academic, San Diego Fleischer RL (1962) Rapid solution hardening, dislocation mobility, and the flow stress of crystals. J Appl Phys 33: 504–3508 Patra A, Zhu T, McDowell DL (2014) Constitutive equations for modeling non-Schmid effects in single crystal bcc-Fe at low and ambient temperatures. Int J Plast 59:1–14 Hiratani M, Zbib HM, Khaleel MA (2003) Modeling of thermally activated dislocation glide and plastic folw through local obstacles. Int J Plast 19:1271–1296 Yanilkin AV, Krasnikov VS, Kuksin AY, Mayer AE (2014) Dynamics and kinetics of dislocations in Al and Al-Cu alloy under dynamic loading. Int J Plast 55:94–107 Int J Adv Manuf Technol 26. 27. Yang ZS, Yu ZH, Wu HX, Chang DF (2014) Laser-induced thermal damage detection in metallic materials via acoustic emission and ensemble empirical mode decomposition. J Mater Process Technol 214:1617–1626 American Society for Testing and Materials (2008) ASTM E 837– 08 Standard test method for determining residual stresses by the 28. hole-drilling strain-gage method [S]. ASTM International, Pennsylvania Gu BP, Yang ZS, Pan L, Wei W (2016) Evolution of the microstructure, mechanical properties, and high-order modal characteristics of AISI 1045 steel subjected to a simulative environment of surface grinding burn. Int J Adv Manuf Technol 82:253–263
0
You can add this document to your study collection(s)
Sign in Available only to authorized usersYou can add this document to your saved list
Sign in Available only to authorized users(For complaints, use another form )