CHAPTER 1 INTRODUCTION 1.1 Background of the study Corrosion is a pervasive issue in numerous industries, causing material degradation, structural failures, and substantial economic losses (smith, 2018). Mild steel, valued for its cost-effectiveness and mechanical properties, is particularly vulnerable to corrosion, making corrosion inhibition a critical aspect of material protection (Jafari et al, 2021). Conventional corrosion inhibitors typically rely on synthetic chemicals, which, though effective, often raise concerns about their environmental impact and potential health risks (Zheng et al, 2017). In recent years, there has been a growing emphasis on exploring the potential of natural compounds, particularly phytochemicals derived from plants, as eco-friendly and sustainable alternatives for corrosion inhibition (Hosseini et al, 2020). Natural compounds offer distinct advantages, such as biodegradability and low toxicity, which are environmentally and ecologically desirable (El Achaby et al, 2021). One intriguing source of phytochemicals is palm bunch spiklets, which are residual agricultural materials left after palm oil extraction. These spiklets have been found to contain various bioactive compounds, including phenolic compounds, flavonoids, tannins, and alkaloids (Shahidi et al, 2015; Hasan et al, 2020). Hexane, a commonly used solvent, is preferred for the extraction of phytochemicals from plant materials due to its nonpolar properties, allowing efficient extraction of lipophilic compounds like phenolic acids and essential oils (Jovanović et al, 2020). Furthermore, introducing diluted hydrochloric acid into the extract has the potential to enhance the solubility of specific phytochemicals and influence their corrosion inhibition properties (Duan et al, 2018). Hydrochloric acid, being a strong mineral acid, can create an acidic environment, which may alter the chemical interactions 1 between the phytochemicals and the mild steel surface (Zhang et al., 2017). Mild steel, also known as low mild steel or plain-mild steel, is a fundamental material widely used in engineering and construction due to its versatility and affordability (Adekunle et al., 2015). It is primarily composed of iron, typically containing a small percentage of carbon, generally ranging from 0.05% to 0.25% (smith, 2018). This lower carbon content sets mild steel apart from higher mild steels and imparts specific properties that make it suitable for a broad range of applications. The relatively low carbon content in mild steel contributes to its exceptional formability, weldability, and machinability (Chen et al., 2016). It can be easily shaped, bent, and welded into various structural components and is a popular choice for construction, automotive, and manufacturing industries. Mild steel is characterized by its malleability, making it ideal for processes such as forging, rolling, and bending (El-Etre et al., 2006). Its moderate strength allows it to support significant loads without becoming overly brittle or susceptible to fracture. Additionally, mild steel exhibits good corrosion resistance, but its susceptibility to rusting in certain environments can be mitigated through the use of protective coatings or corrosion inhibitors (Raja et al., 2016). Overall, mild steel's balance of strength, versatility, and cost-effectiveness makes it a foundational material in many industrial and construction applications. In a hydrochloric acid (HCl) environment without any inhibitor, mild steel is highly susceptible to corrosion. HCl is a strong and highly corrosive acid that can rapidly attack the iron content in mild steel. When exposed to HCl, the acid reacts with the iron to form iron chloride (FeCl2 and FeCl3), which is soluble in water, causing the metal to deteriorate and lose its structural integrity (Jones, 1996). The corrosion process in HCl typically involves the dissolution of the iron surface, 2 leading to the formation of hydrogen gas and the release of iron ions into the surrounding solution. This results in the degradation of the mild steel structure, with the development of pits, surface irregularities, and a loss of material thickness (Revie & Uhlig, 2008). Over time, untreated mild steel in an HCl environment will experience extensive corrosion, ultimately leading to material failure and structural damage. Plant extract corrosion inhibitors are natural compounds derived from various parts of plants, including leaves, stems, roots, and fruits, that have demonstrated the ability to mitigate corrosion of metals and alloys (Obi-Egbedi et al., 2007). These inhibitors are considered environmentally friendly alternatives to synthetic corrosion inhibitors due to their biodegradability and lower toxicity (Yaro et al., 2017). They offer a sustainable approach to protecting metallic materials from degradation in corrosive environments (Fouda et al., 2014). Plant extracts typically contain a variety of phytochemicals, such as phenolic compounds, flavonoids, tannins, alkaloids, and organic acids, which have been found to possess corrosion inhibiting properties (Rahman et al., 2018). These compounds can adsorb onto the metal surface, forming a protective layer that impedes the corrosion process (Adekunle et al., 2015). Additionally, some plant extracts have the ability to alter the pH and chemical composition of the surrounding environment, making it less conducive to corrosion (Eddy et al., 2008). Overall, plant extract corrosion inhibitors represent a sustainable and eco-friendly approach to corrosion control, offering a promising avenue for the development of effective and environmentally responsible solutions for protecting metal and alloy surfaces in corrosive conditions (Popoola et al., 2015). 3 1.2 Statement of the Problem Corrosion represents a substantial challenge in various industrial and structural applications, leading to material degradation and significant economic losses. Mild steel, a widely used construction material, is particularly susceptible to corrosion, especially in acidic environments. To combat this issue, traditional synthetic corrosion inhibitors have been employed. However, the environmental and health concerns associated with these inhibitors necessitate the exploration of more sustainable and eco-friendly alternatives. Plant extract corrosion inhibitors have emerged as potential green solutions. Still, their effectiveness in complex corrosive media, such as with diluted hydrochloric acid, remains relatively unexplored. Therefore, this research seeks to assess the corrosion inhibition properties of plant extract derived from palm bunch spiklets in this unique environment 1.3 Purpose of Study The primary purpose of this research is to evaluate the potential of plant extract derived from palm bunch spiklets as an eco-friendly corrosion inhibitor for mild steel in diluted hydrochloric acid media. 1.4.1 Aim: The primary aim of this study is to assess the effectiveness of plant extract derived from palm bunch spiklets as a corrosion inhibitor for mild steel in hexane-based solutions with diluted hydrochloric acid. 1.4.2 Objectives: 4 The specific objectives of the research are to: 1. To extract phytochemicals from palm bunch spiklets using hexane in a cold extraction process. 2. To introduce diluted hydrochloric acid into the extract to form a solution. 3. To evaluate the corrosion inhibition properties of the palm bunch spiklet extract on mild steel metal coupons immersed in the solution. 4. To determine the mechanism of the corrosion inhibition. 1.5 SCOPE OF STUDY The scope of this research encompasses a thorough investigation of the corrosion inhibition properties of plant extract derived from palm bunch spiklets in hexanebased solutions with diluted hydrochloric acid, with a specific focus on mild steel. The study will commence by utilizing a cold extraction process using hexane to extract phytochemicals from palm bunch spiklets, allowing for the identification and isolation of relevant phytochemical compounds within the extract. Subsequently, this extract will be introduced into a solution with diluted hydrochloric acid, simulating a corrosive industrial environment. The study's core involves the evaluation of the corrosion inhibition effectiveness of the palm bunch spiklet extract on mild steel metal coupons immersed in the solution. To ascertain the efficacy of the extract as a corrosion inhibitor, various analytical techniques will be employed, including FourierTransform Infrared Spectroscopy (FTIR) to understand molecular interactions, Gas Chromatography-Mass Spectrometry (GC-MS) for compound identification, Scanning Electron Microscopy (SEM) to visualize corrosion behaviour, and electrochemical testing for corrosion rate measurements. This holistic approach aims to provide a comprehensive assessment of the extract's potential in mitigating mild steel 5 corrosion in acidic environments. CHAPTER 2 LITERATURE REVIEW 2.1 Extent of Past Works Izionworu et al (2013). Worked on A Study of Wire Croton as an Inhibitor of Mild Steel in HCL Using Electrochemical, SEM, GCMS, and FTIR Measurements. Their work delves into the electrochemical and inhibitive properties of Codiaeum Variegatum Brilliantissima - Zanzibar (CVB-WC) extract in mitigating mild steel corrosion within a hydrochloric acid (HCl) environment. Notably, the research identifies the inhibitive components within the CVB-WC extract, which encompass terpenes, tannins, alkaloids, flavonoids, and phytate, characterized by functional groups containing heteroatoms and aromatic ring-shaped structures. The study achieves a remarkable inhibition efficiency (IE%) of 96.1%, indicating the high effectiveness of CVB-WC as a mild steel corrosion inhibitor, consistent with prior weight loss findings. The mechaniEG of inhibition involves molecular adsorption, where the heteroatoms in the inhibitor bond with the charged mild steel surface in 6 the corrosive HCl environment, forming a protective layer that reduces corrosion. Scanning electron microscopy (SEM) images illustrate the protective effect of CVBWC, reinforcing the practicality of this eco-friendly corrosion inhibition approach with potential applications across industries. Izionworu et al (2020).worked on inhibition of mild steel corrosion in acidic medium using theobroma cacaopod. Their work explores the corrosion inhibitive properties of Thevetia Peruviana leaves extract on mild steel in a hydrochloric acid (HCl) environment. The study investigates the inhibitive effects at various temperatures and concentrations of TCP-CP extract. The adsorption isotherms, including Langmuir, Temkin, and Freundlich, illustrate the adsorption behavior of the inhibitor on the mild steel surface. The thermodynamic and activation parameters, such as standard enthalpy of activation (ΔH O ), standard entropy of activation (ΔS O ), and apparent activation energy (E a ), are calculated to understand the corrosion process. The research indicates that TCP-CP extract effectively inhibits mild steel corrosion in an HCl environment, with inhibition efficiency depending on both concentration and time of immersion. The inhibitive mechaniEG is proposed to involve the adsorption of TCP-CP molecules on the metal surface via heteroatoms and functional groups. Onwubiko et al (2023). Worked on Kinetic Parameters of Corrosion Rate constant for Water-Based Plants for the Inhibition of Metal in Acidic Medium. Their work investigates the kinetic parameters of metal inhibition in an acidic medium using water-based plant extracts to monitor corrosion rate characteristics. The study focuses on the corrosion of mild steel in the presence of hydrochloric acid and two plant extracts, Pnematopteris pennigera () and Selaginella myosurus (EG). 7 Notably, the research observes variations in the corrosion rate constant, K, with changes in temperature, highlighting the role of temperature in the corrosion process. Furthermore, the inhibition efficiency, Ei, increases initially with time but experiences a sudden decrease, suggesting that the effectiveness of the plant extract-based corrosion inhibition is time-dependent. Additionally, the study finds that higher temperatures enhance inhibition efficiency. Ultimately, this research underscores the potential of water-based plant extracts, specifically and EG, as effective corrosion inhibitors in an acidic medium, offering valuable insights for the field of corrosion science. Onwubiko et al (2023). Worked on Monitoring the Effect of Temperature and Time on the Characteristics of Metal Sample Corrosion Rate Inhibition using Selaginella myosurus and Pneumatoptens pennigera (SM &GF) Plants. Their work investigates the impact of temperature and exposure time on the weight loss and corrosion rate of metal using two plant extracts, Selaginella myosurus and Pneumatoptens pennigera (SM & GF). The study examines weight loss over a temperature range of greater than 300°C to less than 385°C and exposure times ranging from 20 hours to 120 hours, noting fluctuations in weight loss. Notably, the research observes a decrease in weight loss at temperatures above 300°C but less than 315°C, followed by an increase at temperatures greater than 315°C, and a subsequent decrease at temperatures exceeding 330°C. Additionally, an increase in weight loss is observed with prolonged exposure time, and the correlation between weight loss (in milligrams) and time (in hours) for metal samples undergoing corrosion rate inhibition with the presence of plant extract and a 1.0 molar HCl corrosive solution demonstrates an increase in weight loss. This research highlights the significance of Selaginella myosurus and Pneumatoptens pennigera () Plant in 8 monitoring the resistance to metal weight loss and corrosion rate, particularly in the context of exposure to varying temperatures and time periods. Adekunle, et al (2017). Worked on Corrosion inhibition of mild steel by plant extracts in acidic media. This review article discusses the corrosion inhibition of mild steel in acidic environments using plant extracts as inhibitors. The study provides a comprehensive overview of the research conducted in this area. The authors begin by introducing the importance of corrosion and the need for effective inhibitors, especially in acidic media where mild steel is highly susceptible to corrosion. They emphasize the environmental and economic advantages of using green inhibitors derived from plant extracts. The review covers a range of plant extracts and their corrosion inhibition properties. It delves into the mechanism by which these extracts interact with the metal surface to inhibit corrosion, which often involves adsorption and the formation of protective films. A significant portion of the article is dedicated to the evaluation of various plant extracts and their inhibitive efficiencies. This involves discussing the experimental methods, including electrochemical tests and corrosion rate measurements, used by different researchers to assess the performance of these inhibitors. The authors highlight the potential of plant extracts as green and sustainable corrosion inhibitors and suggest that further research is needed to explore their full potential. They also point out the importance of identifying the active compounds within these extracts to enhance their inhibitive properties. El-Etre, et al (2006). Worked on Natural honey as corrosion inhibitor for metals and alloys. 9 This research article explores the potential of natural honey as a corrosion inhibitor for various metals and alloys. The study investigates the inhibitory properties of honey in different corrosive environments and highlights its application in corrosion control. The authors introduce the significance of corrosion in various industries and the need for effective corrosion inhibition methods. They emphasize the importance of finding environmentally friendly and cost-effective alternatives to traditional inhibitors. The study includes experimental investigations that assess the corrosion inhibition efficiency of honey. Researchers conducted electrochemical tests and corrosion rate measurements in the presence of honey to evaluate its protective effects on metal surfaces. The results of the experiments demonstrate that natural honey has notable corrosion inhibition properties. It forms a protective film on metal surfaces, reducing the corrosion rate and extending the service life of the materials. The authors discuss the mechanism by which honey interacts with metal surfaces to inhibit corrosion, highlighting its adsorption and film-forming characteristics. The article concludes that natural honey can serve as a promising and eco-friendly corrosion inhibitor for various metals and alloys. It provides a practical and sustainable solution to mitigate corrosion-related issues in different industrial applications. Eddy et al (2008).Worked on Inhibition of mild steel corrosion in hydrochloric acid solution by methanolic extract of leaves of Piliostigma thonningii. This research article investigates the potential of the methanolic extract of leaves from the Piliostigma thonningii plant as a corrosion inhibitor for mild steel in 10 hydrochloric acid solutions. The study aims to assess the inhibitory properties of the plant extract and its application in mitigating the corrosion of mild steel. The authors introduce the issue of corrosion in industrial settings, emphasizing the importance of finding effective and environmentally friendly corrosion inhibitors. They focus on the natural extract from Piliostigma thonningii as a potential green inhibitor. The study includes experimental investigations to evaluate the corrosion inhibition efficiency of the methanolic extract. Researchers conducted electrochemical tests, corrosion rate measurements, and surface analysis to assess the extract's protective effects on mild steel. The results indicate that the methanolic extract of Piliostigma thonningii leaves demonstrates significant corrosion inhibition properties. It effectively reduces the corrosion rate of mild steel in hydrochloric acid solutions. The authors discuss the mechanism by which the plant extract interacts with the metal surface, which may involve adsorption and film formation. The article concludes that the methanolic extract of Piliostigma thonningii leaves holds promise as a natural and eco-friendly corrosion inhibitor for mild steel in acidic environments. It provides a practical solution for industries seeking sustainable corrosion control methods. Fouda et al (2014).Worked Inhibition of mild steel corrosion in hydrochloric acid solution by alkaloid extract from Anabaena oryzae. This research article explores the potential of an alkaloid extract from Anabaena oryzae as a corrosion inhibitor for mild steel in hydrochloric acid solutions. The study aims to assess the inhibitory properties of the alkaloid extract and its application in 11 mitigating the corrosion of mild steel in acidic environments. The authors introduce the challenge of corrosion in industrial settings and the need for effective corrosion control methods. They highlight the significance of finding eco-friendly and sustainable inhibitors to protect metal surfaces. The study involves experimental investigations to evaluate the corrosion inhibition efficiency of the alkaloid extract. Researchers conducted electrochemical tests and corrosion rate measurements to assess its protective effects on mild steel. The results indicate that the alkaloid extract from Anabaena oryzae demonstrates notable corrosion inhibition properties. It effectively reduces the corrosion rate of mild steel in hydrochloric acid solutions, highlighting its potential as an eco-friendly inhibitor. The article concludes that the alkaloid extract from Anabaena oryzae has promising applications as a natural and sustainable corrosion inhibitor for mild steel in acidic environments. It provides a practical solution for industries seeking environmentally responsible corrosion control methods. Jovanović et al (2020).Worked on Evaluation of green solvents in the extraction of bioactive compounds from plant materials. This research article focuses on the evaluation of green solvents in the extraction of bioactive compounds from plant materials. The study aims to assess the effectiveness of environmentally friendly solvents in extracting valuable compounds from plants, with a focus on their potential applications in various industries, including pharmaceuticals, food, and cosmetics. The authors introduce the importance of finding sustainable and eco-friendly extraction methods for bioactive compounds from plants. Traditional extraction processes often involve the use of hazardous solvents, which can have adverse 12 environmental and health impacts. Green solvents offer a more environmentally responsible alternative. The study includes experimental investigations to compare different green solvents in the extraction of bioactive compounds. Researchers examine the efficiency of these solvents in isolating valuable compounds from plant materials. Analytical techniques may be used to identify and quantify the extracted compounds. The results of the study provide insights into the performance of various green solvents, their selectivity, and their potential for large-scale extraction processes. This research contributes to the development of more sustainable and environmentally friendly practices in the extraction of bioactive compounds. Khayati et al (2014). Worked Corrosion inhibition of mild steel in 1 M hydrochloric acid solution by some derivatives of chitosan. This research article investigates the corrosion inhibition of mild steel in a 1 M hydrochloric acid solution using derivatives of chitosan. The study aims to assess the potential of chitosan derivatives as effective corrosion inhibitors for mild steel in acidic environments. The authors highlight the significance of corrosion control in industrial settings, especially in acidic solutions where metals like mild steel are prone to degradation. They introduce the use of chitosan derivatives as a possible eco-friendly and sustainable solution to mitigate corrosion. The study involves experimental investigations to evaluate the corrosion inhibition efficiency of chitosan derivatives. Researchers conducted electrochemical tests and corrosion rate measurements to assess the protective effects of these derivatives on mild steel. The results demonstrate that some derivatives of chitosan show notable corrosion 13 inhibition properties. They effectively reduce the corrosion rate of mild steel in a 1 M hydrochloric acid solution, highlighting their potential as eco-friendly inhibitors in acidic environments. The article concludes that chitosan derivatives have promising applications as natural and sustainable corrosion inhibitors for mild steel in acidic media. Their use can provide a practical solution for industries seeking environmentally responsible corrosion control methods. Obi-Egbedi et al (2007). Worked on The role of Xylopia aethiopica in corrosion control. This research article investigates the potential of Xylopia aethiopica, a plant extract, in corrosion control. The study focuses on understanding the inhibitive properties of Xylopia aethiopica and its applications in mitigating corrosion in various industrial and environmental contexts. The authors emphasize the significance of corrosion control, particularly in industrial settings where materials are exposed to corrosive environments. They introduce Xylopia aethiopica as a natural substance that has shown promise as a corrosion inhibitor. The study includes experimental investigations to assess the corrosion inhibition efficiency of Xylopia aethiopica. Researchers examine the ability of this plant extract to reduce the corrosion rate of metals, potentially offering an eco-friendly solution for corrosion protection. The results of the study demonstrate that Xylopia aethiopica exhibits corrosion inhibition properties, and it can effectively reduce the corrosion rate of metals. This 14 suggests its potential use in various industrial applications where corrosion control is crucial. The article concludes that Xylopia aethiopica has a role to play in corrosion control, offering an eco-friendly and sustainable solution for industries seeking environmentally responsible corrosion inhibition methods. Raja et al (2016). Worked on Corrosion inhibition of mild steel in hydrochloric acid solution by fruit juice of Citrus sinensis as green inhibitor. This research article investigates the corrosion inhibition properties of the fruit juice of Citrus sinensis (commonly known as sweet orange) as a green inhibitor for mild steel in a hydrochloric acid solution. The study focuses on the potential of fruit juice to act as an eco-friendly and sustainable corrosion inhibitor. The authors begin by emphasizing the importance of corrosion control, especially in acidic environments. They introduce Citrus sinensis fruit juice as a potential natural source of corrosion inhibition compounds. The study aims to evaluate the effectiveness of this fruit juice in reducing the corrosion rate of mild steel. Experimental investigations are carried out to assess the corrosion inhibition efficiency of Citrus sinensis fruit juice. Researchers examine the ability of the fruit juice to form a protective film on the mild steel surface, thereby reducing the corrosion rate. Various corrosion parameters are analysed to determine the effectiveness of the fruit juice as a green inhibitor. The results of the study indicate that Citrus sinensis fruit juice exhibits corrosion inhibition properties. It forms a protective film on the mild steel surface, reducing the corrosion rate in hydrochloric acid. This suggests the potential use of fruit juice as an eco-friendly corrosion inhibitor in acidic environments. The article concludes that Citrus sinensis fruit juice has promise as a green inhibitor 15 for mild steel corrosion in hydrochloric acid solutions. This finding provides valuable insights for industries seeking sustainable and environmentally responsible corrosion control methods. Umoren et al (2013). Worked on Inhibitive and adsorption properties of ethanol extracts of Allophylus africanus for the corrosion of mild steel in H2SO4. This research article investigates the inhibitive and adsorption properties of ethanol extracts obtained from Allophylus africanus for mitigating the corrosion of mild steel in sulfuric acid (H2SO4) solutions. The study focuses on the potential of natural extracts from Allophylus africanus as corrosion inhibitors in acidic environments. The authors emphasize the significance of corrosion control in acidic solutions, especially in industrial applications where mild steel is commonly used. They introduce Allophylus africanus as a potential source of natural inhibitors and aim to assess its effectiveness in reducing the corrosion rate of mild steel in H2SO4. Experimental investigations are conducted to evaluate the inhibitive properties of ethanol extracts from Allophylus africanus. The study explores the ability of these extracts to adsorb onto the mild steel surface, forming a protective layer that mitigates corrosion. Various corrosion parameters are examined to determine the effectiveness of the extracts as inhibitors. The study's findings reveal that ethanol extracts from Allophylus africanus exhibit corrosion inhibition properties. They effectively adsorb onto the mild steel surface, forming a protective layer that reduces the corrosion rate in H2SO4. This suggests the potential use of these natural extracts as eco-friendly corrosion inhibitors in acidic environments. The article concludes that Allophylus africanus ethanol extracts have promise as green inhibitors for mitigating mild steel corrosion in sulfuric acid solutions. This 16 research contributes valuable insights to the field of eco-friendly corrosion control, offering a sustainable and environmentally responsible approach to combating corrosion in acidic environments. Singh et al (2020). Worked Corrosion Behaviour of Mild Steel in Different Concentrations of Hydrochloric Acid. The research conducted by Singh et al in 2020 investigates the corrosion behaviour of mild steel in different concentrations of hydrochloric acid. The study was published in the journal Materials Research Express. The authors conducted experimental analyses to understand how mild steel responds to varying concentrations of hydrochloric acid, which is a common acidic environment known for its corrosive properties. The research aims to shed light on the degradation mechanism of mild steel under different acid concentrations and provide insights into the corrosion resistance of the material. The results of this study may have implications for industries that use mild steel in environments with acidic media and contribute to the development of protective measures against corrosion. Yusuf et al, (2020).Worked on Corrosion Inhibition of Mild Steel in Acidic Medium Using Natural Extracts. The review provides a comprehensive overview of experimental studies and research conducted on the topic. It discusses the effectiveness of different natural extracts in inhibiting the corrosion of mild steel and highlights their advantages as eco-friendly and sustainable alternatives to synthetic inhibitors. The article also delves into the underlying mechanism of corrosion inhibition by natural extracts and their interaction with the metal surface. It discusses the role of phytochemicals and active compounds present in these extracts that contribute to their inhibitive properties. 17 Furthermore, the review addresses the challenges and limitations associated with the use of natural extracts as corrosion inhibitors. It emphasizes the importance of optimizing their effectiveness and stability to ensure their practical applicability in industrial settings. Ramezanzadeh, B., & Mahdavian, M. (2015). Worked on Corrosion of Mild Steel in Acidic Media: Influence of Immersion Time and Acid Concentration. The study involves subjecting mild steel samples to different immersion times in acidic solutions of varying concentrations. The researchers carefully monitored the corrosion rate and assessed the extent of material degradation over time. By systematically varying the immersion conditions, they gain insights into the relationship between immersion time, acid concentration, and the rate of corrosion. The article presents detailed experimental data and provides graphical representations to illustrate the corrosion behaviour of mild steel under different conditions. It also discusses the significance of the findings in understanding the factors that contribute to accelerated corrosion in acidic environments, which can be relevant in industrial settings and practical applications. The research highlights the importance of considering both immersion time and acid concentration when evaluating the corrosion resistance of mild steel. The results contribute to a better understanding of the corrosive behaviour of mild steel in acidic media and can aid in the development of corrosion prevention strategies and the selection of appropriate materials for specific applications. Das, A., & Gupta, M. (2016). Worked on Effect of Inhibitors on the Corrosion of Mild Steel in Acidic Solutions. The review highlights the significance of mild steel corrosion in acidic media and the detrimental effects it can have on various 18 industrial applications. The study emphasizes the importance of developing effective corrosion inhibition strategies to protect mild steel from degradation in acidic environments. Through the examination of various inhibitors, the authors assess their ability to inhibit corrosion and protect mild steel. Different types of inhibitors and their mechanism of action are thoroughly discussed, providing valuable insights into their potential as corrosion protection agents. The review also investigates the influence of inhibitor concentration, immersion time, and other environmental factors on the inhibitive performance. It critically analyses experimental studies and presents key findings, facilitating a comprehensive understanding of the corrosion inhibition process. Rajapakse et al, (2014) Worked, on Investigation of the Mechanical Properties of Mild Steel using Digital Image Correlation (DIC) Technique. The research utilized mild steel samples subjected to mechanical testing, and the DIC technique was employed to monitor and quantify the deformation and strain distributions during the experiments. By analysing the digital images of the deformed samples, the researchers were able to assess mechanical properties such as Young's modulus, ultimate tensile strength, and yield strength of the mild steel. The study's findings shed light on the mechanical behaviour of mild steel, providing valuable insights into its deformation characteristics and mechanical properties. The use of the DIC technique allowed for precise and accurate measurements of strain, contributing to a better understanding of the material's response to mechanical forces. This research is significant for various engineering applications where the mechanical properties of mild steel are crucial for design and structural integrity 19 considerations. Farooq et al, (2015). Worked on the, Physical and Chemical Properties of Hydrochloric Acid. The work provides a comprehensive overview of the physical and chemical properties of hydrochloric acid (HCl). The authors present detailed information about the characteristics of HCl, including its physical state, appearance, density, solubility, and pH level. They also explore the chemical properties of HCl, such as its chemical formula, molecular weight, and chemical reactions with different substances. The study sheds light on the various applications of hydrochloric acid in industries, laboratories, and other fields. It emphasizes the significance of understanding the properties of HCl to ensure safe handling and storage, given its corrosive nature. Overall, this research article serves as a valuable resource for individuals seeking to gain knowledge about the properties and uses of hydrochloric acid in different contexts. 2.1.1 Corrosion and Its Mechanism Corrosion, as a ubiquitous electrochemical process, encompasses the deterioration of metals through reactions with their environment. The fundamental principles underlying corrosion are electrochemical in nature. It involves the movement of electrons and ions, leading to the degradation of metal surfaces (Jones, 1996). In acidic environments, the corrosion mechanism are particularly pronounced. One of the primary mechanism is the anodic dissolution of the metal, which releases metal ions into the solution (Duan et al., 2018). This is accompanied by the reduction 20 of oxygen or other oxidants, leading to the formation of hydroxide ions. The anodic and cathodic reactions are interconnected, and corrosion occurs when the rate of metal dissolution exceeds the rate of protective film formation (Revie & Uhlig, 2008). Another mechanism in acidic corrosion involves the hydronium ion (H3O+) that aids in the dissolution of metal ions (Zhang et al., 2017). Acidic solutions provide an environment where the hydronium ions can contribute to the corrosion process, making the metal surface more susceptible to degradation. Understanding these corrosion mechanism is essential for developing effective corrosion inhibitors, especially in acidic media. The study of corrosion in acidic environments is crucial due to the prevalence of such conditions in industrial settings and the heightened corrosion rates that result from them (Rahman et al., 2018). 2.1.2 Corrosion Inhibitors Corrosion inhibitors are substances that play a vital role in protecting metals and alloys from the deleterious effects of corrosion. They work by interfering with the corrosion process or by forming a protective layer on the metal surface, effectively preventing the electrochemical reactions that lead to metal degradation (Obi-Egbedi et al., 2007). There are various types of corrosion inhibitors, including organic and inorganic compounds, metallic coatings, and even nanomaterials. However, in recent years, there has been a growing emphasis on the development of green and sustainable corrosion inhibitors due to environmental and health concerns associated with traditional inhibitors (El Achaby et al., 2021). Plant extracts have emerged as a promising category of green corrosion inhibitors. These extracts contain various phytochemical compounds, such as phenolics, 21 flavonoids, and alkaloids, which have demonstrated the ability to inhibit corrosion effectively (Adekunle et al., 2017). The shift toward plant extracts is driven by their biodegradability, low toxicity, and potential to provide eco-friendly solutions to corrosion-related challenges (Jafari et al., 2021). As industries seek more sustainable and environmentally responsible corrosion inhibition strategies, plant extracts represent a promising avenue. They offer the possibility of mitigating corrosion while minimizing the negative environmental impact often associated with conventional corrosion inhibitors. 2.1.3 Plant Extracts as Corrosion Inhibitors Corrosion inhibition using plant extracts has gained considerable attention in recent years, reflecting the global shift towards environmentally friendly and sustainable solutions in various industries. Numerous studies have investigated the effectiveness of different plant extracts as corrosion inhibitors and their underlying mechanism, offering valuable insights into the potential of these eco-friendly compounds (Rahman et al., 2018). A comprehensive body of literature, including studies by Rahman et al. (2018), has examined the corrosion inhibitive properties of plant extracts. These studies encompass a wide array of plant sources, ranging from fruits and leaves to seeds and bark. This diversity highlights the rich potential of plant extracts in corrosion control, underscoring their versatility and applicability in different industrial scenarios (Popoola et al., 2015). Research findings consistently reveal the effectiveness of plant extracts in mitigating corrosion. These extracts contain phytochemical compounds such as phenolics, flavonoids, and alkaloids that form protective films on metal surfaces 22 (Adekunle et al., 2017). The formation of these films, through processes like adsorption and chemical interaction, shields metals from corrosive agents. Studies often employ electrochemical techniques, such as potentio-dynamic polarization and electrochemical impedance spectroscopy, to quantify the corrosion inhibition efficiency and unravel the underlying mechanism (Khayati et al., 2014). While plant extracts show promise, there are still gaps and areas for improvement in the field. These include the need for a deeper understanding of the specific phytochemical compounds responsible for corrosion inhibition and the development of standardized testing methods to evaluate their performance. Additionally, exploring the synergistic effects of combining multiple plant extracts and the potential enhancement of their properties through modification or encapsulation techniques represent promising directions for future research (Khaled et al 2020). 2.1.4 Analytical Methods 1. Fourier Transform Infrared Spectroscopy (FTIR): Principle: FTIR is a technique used for identifying functional groups in a molecule based on their vibrational frequencies. It measures the absorption of infrared radiation by a sample. Procedure: Sample Preparation: The sample is prepared as a thin film or placed in a suitable medium that is transparent to infrared radiation. Instrumentation: A FTIR spectrometer is used, consisting of an interferometer and a detector. The 23 interferometer modulates the infrared light, and the resulting interferogram is Fourier -transformed to obtain the infrared spectrum. Measurement: Infrared light is passed through the sample, and the absorption of specific wavelengths is recorded. The resulting spectrum represents the molecular vibrational modes. Data Analysis: Peaks in the spectrum correspond to specific functional groups in the sample. The position and intensity of these peaks provide information about the chemical composition. Applications: Identification of organic and inorganic compounds. Analysis of polymers, pharmaceuticals, and chemicals. Quality control in various industries. 24 25 Fig 2.1 Schematic sketch of the essential features of a Fourier transform infrared (FTIR) spectrometer. 2. Gas Chromatography-Mass Spectrometry (GC-MS): Principle: GC-MS is a powerful analytical technique used for separating and identifying components in a mixture. It combines gas chromatography to separate compounds and mass spectrometry to identify them based on their mass-to-charge ratio. Procedure: Sample Injection: The sample is injected into a gas chromatograph, where it is vaporized and separated into individual components based on their chemical properties. Separation: The separated compounds travel through a column, and their retention times are recorded. Ionization: As the compounds exit the column, they enter the mass spectrometer, where they are ionized by electron impact or chemical ionization. Mass Analysis: The ions are accelerated through a magnetic field, causing them to follow a curved path. The degree of curvature is proportional to the mass-to-charge ratio (m/z). The resulting mass spectrum is obtained. Data Interpretation: Peaks in the mass spectrum represent different compounds. The mass spectrum is compared to a database for compound identification. Applications: 26 Identification of volatile and semi-volatile organic compounds. Drug testing, environmental analysis, and forensic investigations. Fig 2.2 Schematic diagram of the main components of GC–MS instruments 3. Scanning Electron Microscopy (SEM): Principle: SEM is a microscopy technique that provides high-resolution images of the surface of a sample using electron beams. Procedure: Sample Preparation: The sample is typically coated with a thin layer of conductive material (e.g., gold) to enhance conductivity and improve imaging. Instrumentation: The SEM consists of an electron gun, electromagnetic lenses, and a detector. Electron beams are focused on the sample surface, and secondary electrons emitted 27 from the sample are detected. Imaging: The electron beam scans the sample surface, and the emitted electrons are collected to create an image. The resolution is much higher than that of optical microscopes. Analysis: SEM allows for three-dimensional imaging and analysis of the surface morphology of the sample. Elemental analysis can also be performed using energy-dispersive Xray spectroscopy (EDS) attachments. Applications: Surface morphology analysis of materials. Examination of biological specimens, minerals, and various materials at a micro- to nanoscale level. Quality control in manufacturing and research. 28 29 Fig 2.3 Schematic diagram of the main components of SEM instruments 2.2 Limitation of Past Works While plant extracts have shown promise as green corrosion inhibitors, prior works have certain limitations. Most studies have examined common crops like neem, papaya, rice bran etc. (Raja and Sethuraman, 2008). Investigations on effectiveness of palm oil biomass, though showing good inhibition, predominately use methanol/ethanol extraction only (Okafor et al. 2008). A few analyse palm kernel oil without optimizing hexane extraction potential. Research correlating extraction processes of spikelets from oil palm bunches tailoring them as corrosion inhibitors is lacking (Geethamani and Kasthuri, 2015). Quantification of environmentallyresponsible phytochemical utilization avenues for these residues is needed. Moreover, electrochemical evaluations have been restricted to soluble extracts rather than using dispersions which better mimic industrial conditions. 2.3 Current Work The current study focuses on sustainably utilizing palm bunch spikelets, an underleveraged biomass side stream from palm oil processing as a corrosion inhibitor. Non-polar phytochemical fractions are specifically extracted using hexane. Systematic dosage concentration optimization coupled with multiple characterization techniques will assess functionality in acidic media from application perspectives. 2.4 Expected Outcome The work can pave the way for valorizing palm spikelet extracts identified as potent corrosion inhibitors, opening additional revenue avenues for waste biomass reuse in circular bioeconomy models. Optimized extraction and testing methodologies can 30 serve as templates for examining efficacy of other novel bio-derived materials. Characterizing inhibition mechanism can guide designs of tailored green inhibitors and protective coatings. Establishing viability under near real-world conditions is expected to spur adoption across corrosion-susceptible industries, delivering economic gains beyond sustainability. Comparing performance with existing benchmarks can highlight competitiveness. CHAPTER 3 MATERIALS AND METHODS 3.1 Materials The following materials were employed to perform this investigative study on corrosion inhibition of mild steel – Square-shaped channel mild steel (MS metal samples). Plant: Elaeis guineensis. (leafs & stems), desiccators, Silicon carbide paper (Sand paper – 2 grades to include ooth and rough), deionised water, ethanol, hexane, acetone, detergent; Experimental apparatus includes: nose mask, hand glove, laboratory coat, plastic buckets, conical flask, measuring cylinder, glass bottles, rubber thread, Iron brush, basket/filter, a pair scissors, vernier calliper, thermostatic water bath, digital weight balance, electric blender, digital Memmert oven, GC-MS, FTIR, & SEM devices. 31 3.1.1 Mild steel Metal Specimen The compostion of the Square-shaped coupon is as represented in Table 3.1 Figure 3.1 Square-Shaped Metal used as Mild Steel Sample(s) in this Study 3.1.2 Plant used in the Preparation of the Test Inhibitor (Plant extract) used in this Study 32 The plant Elaeis guineensis (also called palm bunch Spike, EG - stems and leafs), was used in this research investigative study. 33 Figure 3.2 Cross Section of Raw (Fresh) Elaeis guineensis after washing with tap water and removing contaminants/impurities 3.2 Methods 3.2.1 Metal Sample Analysis – Chemical composition of mild steel The square-shaped channel metal sample was subjected to Positive Material Identification (PMI) test. This was carried out using X-ray Fluorescent Spectrometer (XRF) – a non- destructive test in which the composition of the mild steel metal sample severed from square – shaped channel was obtained. 3.2.2 Mild Steel Metal Specimen Preparation and Surface Area Determination The metal specimen – Square shaped channel mild steel was bought in Mile III Market building materials lane and machined into length, l = 2.86cm, Height,h = 2.60cm, Width,w = 0.12cm square dimension/shape and a 0.20cm hole drilled through at any chosen upper end of each mild steel metal sample by Rivers State University Workshop (A Division of Rivers State University Port-Harcourt). This hole allows rubber thread to pass through the mild steel sample and tied to enable suspended incubation in the experimental corrosive medium and easy withdrawal of the metal sample from the corrosive medium also. The reference metal, Square shaped mild steel acquired from Mile 3 Market, building materials shops lane before machining was moistened with tap water and cleaned using iron brush followed by silicon carbide paper of various shingle successfully from rough to smooth. The properties of the metal sample was noted and recorded before corrosion investigative study was carried out on the mild steel samples. The machined mild steel was further conscientiously cleaned using smooth sand paper to get cleansed of likely cutting and grinding remnant, degreased with ethanol and 34 further washed in acetone and dried in summery (hot) air. Prior to corrosion investigative study, the cut into square shape metallic samples were reserved and kept safe in air tight equipment to avoid interaction with water containing air using desiccators. The length, width and breath of the mild steel samples and radius of the drilled hole on the metal samples were measured using vernier calliper of good precision and accuracy of least count of 0.02mm. This enabled surface area of the metal specimens to be measured (Chukwure et al., 2020). Total Surface Area of the mild steel sample (A): A = [2(l.w)+2(l.h)+2(h.w)] - 2(Area of drilled hole,hA) Area of drilled hole, hA = πr 2 (3.1) (3.2) Density of mild steel = 7.85g/cm3 M1, - M2, =Mass Concentration of plant Extract in g/L 35 (3.3) Figure 3.3 Square shaped Channel Metal prepared and Cut into Shape – Mild steel Metal Sample 3.2.3 Plant Sample 36 3.2.3.1 Elaeis guineensis – Collection and Preparation The fresh Elaeis guineensis plant (leave and stem) was collected from Ndele, a village in Rundele in Emohua Local Government Area. Elaeis guineensis plant (leaves and stems) was acquired, washed clean with tap water, separated from contaminants or impurities and allowed to lose the tap water through a basket. Then with the aid of a scissors, the plant sample was cut into smaller sizes (size reduction) and afterwards oven dried at 50°C for three hundred hours– 300.00hrs to make it crispy as this made it easy blending to fine powder using a motored blender (Sharma, et al., 2020). 3.2.3.3 Identification of the Active Compounds of the Powdered Plants samples To identify and characterize the active components and molecules of the plant extracts, powdered plants parts were sent for Gas chromatographic mass spectrometry, GC/MS. Gas chromatography/Mass Spectroscopy as a material analysis method employs gas chromatographs fitted with mass selective detectors – mass spectrometer. Gas chromatography – Mass Spectroscopy is an ideal tool used to identify unknown substances or contaminants – test samples in terms quantity and quality that are present in very low quantities. It can be used to study liquid, solid or gaseous samples. The analysis starts with gas chromatography, where the specimen – test sample is productively evaporated into the gas state and separated into its different components using a capillary column coated with a stationary liquid or solid phase. The following method was used to identify the quantity and quality of Elaeis guineensis, using dried powdered test inhibitor sample of EG plant parts. The dried powdered EG plant samples for Gas Chromatography was analysed making use of 37 Agilent 6890 gas chromatograph with 5973 mass spectroscope detector equipped with 60m x 25mm, i.d 0.25μmm/MS DB - WAX capillary column agilent. The characterisation of different plants chemical components was completed following established standard procedure. Also, the phyto-chemical composition of each sample was identified with Agilent 6820 gas chromatograph. The mass spectrum results were translated making use of database from National Institute Standard and Technology (NIST) having over 62,000 patterns. The unknown fragmentation pattern spectra of the unknown components were contrasted with those of known components stored in NIST V. 3.2 library (Appendix A). 3.2.3.4 Preparation of the Plant Extract Elaeis Guineensis Plant Extract 20g of Elaeis Guineensis powder was carefully put into a sizeable plastic container where 1000ml of hexane added to form a mixture which was allowed to ferment for 48.00hrs (Izionworu et al., 2020). Then filtered first with a sieve to remove the chaffs; thereafter carefully filtered again with a white handkerchief that was washed with distilled water to avoid contamination. The filtrate was the Elaeis Guineensis plant extract while the entire residue was dried completely, reweighed (M,EG) and discarded. The filtrate made from EG plant powder was stored in a five litre plastic container pending usage. 38 Figure 3.4 Pictorial flow Diagram for Extract Preparation of Elaeis Guineensis (EG) 3.2.3.5 Analysis of Hexane-Based Plant Extracts – FT-IR The plant extract – dried and grounded Elaeis Guineensis, EG plant was analysed using FT-IR technique and report obtained with FT-IR MODEL Apodization: HappGenzel Agilent technologies spectrophotometer at a frequency of 650/cm. The 39 spectra for the test inhibitors is as represented in Appendix B 3.2.4 Hydrochloric Acid, 1.0M HCl and Distilled Water Preparation The analytical grade – raw hydrochloric acid, HCl, acetone, and ethanol used in this study was acquired from Jereogus Ent Nigeria Ltd, Chemical Shop, Emenike Street, Port Harcourt. The raw – concentrated hydrochloric acid was diluted accordingly into a desired concentration of 1.0M HCl applying standard acid dilution procedure (Izionworu et al., 2020). Preparation of the hydrochloric acid involved dilution to a needful 1.0 Molar concentration HCl. Hydrochloric acid of molecular mass of 36.1g/mol, Assay 36.76; specific gravity 1.18g was used. From dilution calculation, 87.3mls of raw HCl volume was measured using measuring cylinder and added to 3 1000mls volume of distilled water in a container to produce 1.0mol/dm HCl (Izionworu et al. 2020) The distilled water was produced from simple distillation unit of Chemical Engineering Laboratory of the Rivers State University. 3.2.5 Corrodent Medium – Experimental Corrosive Mixture/Medium Preparation Generally, three (3) sets of corrodent medium of 1.0 Molar concentration hydrochloric acid were prepared using raw – concentrated hydrochloric acid, plant extract & hexane – for wholly incubation purpose of the MS metal samples. i. The analytical grade (raw) HCl (87.3mls) was added to 1000mls of the plant extract. ii. The analytical grade (raw) HCl (87.3mls) was added to 500mls of distilled water and varying volumes of (50mls, 100mls, 150mls, 200mls) of the plant extract together. That is, 87.3mls volume of concentrated HCl is contained in 500mls of the distilled water & varying mls of plant extract. (the acid was 40 partly diluted with distilled water – 500mls distilled water + varying mls of plant extract. iii. The analytical grade (raw) HCl (87.3mls) was added to 1000mls of distilled water. That is, standard acid dilution to produce 1.0M HCl. Different volumes of 1.0M HCl was added to complementary volumes of the EG plant extract to make 300mls volume experimental corrosive medium where the medium mild steel samples were immersed wholly, suspended & incubated for 120hrs (5days) at room temperature and other temperatures at 3, 6 and 9.00hrs respectively. 41 Figure 3.5 Pictorial Representations of Prepared Experimental Corrosive Media 3.2.5.1 Elaeis Guineensis (EG) Plant Extract in the Corrodent Medium 20g mass ( M,EG) of powdered EG plant was put into 1000cm3 (1.0dm3) of hexane. 1.29g of EG powdered sample completely dissolved in 1.0 litres distilled water Table 3.1 EG Extract Corrodent Medium Volume/Mass Compositions For Both Hot and Cold Temperatures – Preparation Summary EG Plant Extract + 1.0M HCl Samples Dilute Acid (1.0M HCl) EG Test Inhibitor I (50mls) 5% (50mls – 0.0645g) 100% (300mls) N (100mls) 10% (100mls –0.129 g) 100% (300mls) K (150mls) 15%(150mls – 1935g) 100% (300mls) M (50mls) 20% (200mls – 0.258g) 100% (300mls) J (100mls) O (150mls) L (200mls) C(Control) 100% Volume/Mass Composition (Mass Concentration EG = 10.9423g/L) Corrodent Volume used 100% (300mls) - 100% (300mls) 3.2.6 Experimental Setup for the Determination of Corrosion Rate Inhibition Chemical thermodynamics does not foretell the rate of corrosion but rather offer an understanding to the associated energy forms and changes of corrosion & corrosion inhibition reactions. It is the kinetics of the reaction that foretells the rate at which corrosion reactions proceed. The mild steel samples were tied using rubber thread (conventionally used by hairstylists) through the hole drilled on them to help suspend completely and wholly the metal specimen as it is incubated in each 1.0 Molar concentration hydrochloric acid containing medium (the corrodent solution) for a regulated time of five (5) days at 24.00hrs daily interval withdrawal to determine weight loss of the metal samples. This was done for each mild steel sample in the 1.0 Molar concentration hydrochloric acid containing medium – 300mls corrodent 42 solution of uniform complementary volumes. A known varying volume of the 1.0M HCl acid was added into each glass container to which a known varying complementary volume of the Elaeis Guineensis (EG) plant extract was added to make up 300mls in each case differently to examine the inhibitive effect that could be established using plants extract on 1.0M HCl acid concentrations in a corrosive environment. This was also repeated when the volume of the plant extract was varied to determine the effect of change in volume of Elaeis Guineensis extract on corrosion inhibition on MS metal samples, different volumes-mass composition of 1.0M HCl. The experimental corrosive medium (corrodent mixture) containing the hydrochloric acid dilute concentration and varying volumes of the test inhibitor were tagged K-O 43 Figure 3.6 Weight Losses and Corrosion Rate Experimental Setup at Room Temperature Ten (14) mild steel samples were completely steeped in 300ml volume of each of the experimental medium (corrodent medium) with the aid of a black rubber thread suspending the mild steel samples upright. At the end of twenty four (24) hours, two (2) mild steel samples from each experimental medium was withdrawn, washed and cleaned with soft bristle brush in running water, cleaned with dried rag; washed in ethanol for degreasing, clean with dried rag; dipped into acetone, removed and allowed to dry. In a short while the acetone dries up leaving a thin film on the metal sample surface keeping the samples from interaction with the surrounding as the weighing and reweighing takes place (Izionworu et al., 2020). The mild steel specimens were reweighed to again estimate the changes in metal specimen weight as a result of its incubation in the corrodent mixture and the average weight loss recorded (Umoren, 2018). This was done every 24.00hrs for five (5) days and average weight loss noted in each case. This was carried out for the entire experimental medium labelled J – O, the control experiment inclusive. A control experiment (blank) was also set up as a reference standard to measure, estimate, and compare the inhibitive effect of the Elaeis Guineensis plant extracts on mild steel samples corrosion in 1.0 molar hydrochloric acid concentrations. Finally, the 9.00hrs used mild steel metal samples M, J, O, L and (Blank C) 1.0M HCl were subjected to SEM (scanning electron microscopy) that enabled us visibly perceive patterns established on the mild steel metal samples as a result of varying the volume of the test inhibitor used in investigative experimentations using 1.0 molar dilute hydrochloric acid corrosive medium. The experiments were also done at varying volumes/mass concentrations of the test inhibitors relative to the 44 complementary volumes of 1.0 molar concentration HCl and at varying temperatures. This enabled us to establish the corrosion rate and relevant thermodynamic parameters. Hence adsorption isotherm model and establishing further the contribution of volume of the test inhibitor in the medium. 3.3 Formulated Inhibitor Performance Evaluation In carrying out the experiment: effectiveness of hexane-based extracted palm bunch spiklet plant in the inhibition of MS samples in hydrochloric acid corrodent medium, it was found and can also be seen very clearly that a chemical reaction – oxidationreduction reaction took place as also a physical process of adsorption of the test inhibitors active phytochemical molecular component of great affinity for the metal samples adsorbed on the metal surfaces in the corrodent mixture as shown below through electrochemical weight loss experiment, SEM & FTIR analyses results. 3.3.1 Weight Loss Measurement at different Temperatures and Immersion Times Corrosion reactions involve electron transfer hence regarded an electrochemical processes. Weight loss measurements were accomplished in the process of complete immersion and suspension of the mild steel specimen in stationery oxygenated surrounding with the aid of transparent glass bottles that is capable of accommodating over 300mls of the experimental corrosive mixture (corrodent medium) first at room temperature and later at 303K – 343K sustained each time at constant temperature in a thermostatic water bath (Izionwuru et al, 2020). The preweighed mild steel metal samples were hung with the aid of rubber thread in a glass vessel accommodating 1.0M hydrochloric acid in same volumes of Elaeis Guineensis plant extract for 3, 6, 9hrs in a thermostatic water bath (Izionworu et al., 45 2020). Other concentrations of the test inhibitors were also used. After 3hrs, at a particular temperature, the suspended and incubated mild steel samples contained in the aggregated corrosive medium were withdrawn, thoroughly washed with tap water, dried with hand towel, dipped into acetone, withdrawn and allowed to dry in stream of warm air. Then, using analytical weighing balance reweighed to determine the noted average weight loss by metal specimen. This temperature dependent experiment was carried out for 3.00hrs, 6.00hrs, and 9.00hrs at 303, 313, 323, 333, and 343K (Mayakrishnan et al., 2018). The investigation was done using four (4) mild steel samples were suspended and incubated in each glass bottle of the experimental set-up. This ensured triplicates to randomise possible errors and only the mean value of the weight losses was recorded and presented in tables in the appendix. Furthermore, the weight loss data were employed to determine the rate of corrosion, inhibition efficiency, and thermodynamic parameters applying where necessary appropriate equations (Umoren, 2018; Sangeetha et al. 2020). The weight loss was evaluated using equation 3.5c 3.3.2 Evaluation of Rate of Corrosion A careful observation shows that the volume of liquid displaced by each metal sample in the individual test tube containing acid with or without test inhibitor is equivalent to the volume of the metal specimen. From the volume of the said metal specimen area of the metal can be calculated hence the corrosion rate, CR (Izionworu et al., 2020). The area of the MS metal samples was calculated using Equation 3.1. Rate of corrosion of MS metal samples was evaluated using Equation 3.3 46 CR ( ) ( ) mm = year 87600(W) (g) g 2 D 3 .A(cm ).T(hr) cm (3.3) Where: W = average weight loss of metal sample;A = total surface area of one mtetal sample; 3 T = the immersion time (hrs);D = density of carbon steel (g/cm ) 3.3.3 Evaluation of Rate of Corrosion SC = [ ] [( ] CR,without i-CR, with i C or 1- R, with i CR,without i CR,without i IE% = [ )] (3.4a) CR,without i-CR, with i * 100% CR,without i (3.4b) Where: i = test inhibitor; SC = surface coverage; CR or ROC = Rate of corrosion; IE% = Corrosion inhibition efficiency (Izionworu et al., 2020;Vasanthajothi et al. 2021 3.3.4 Kinetic Parameters 3.3.4.1 Corrosion Rate Constant, K Corrosion rate constant was evaluated using Equation 3.5(a) for first order chemical reaction and Equation 3.5(b) second order chemical reaction. The results are attached to appendix G. ln WDe = lnW0 - Kfit (Adeniji & Bamigbola, 2020) 47 (3.5a) Where: 1 1 = Kset (Levenspiel, 2004) WDe W0 (3.5b) W = W0 - WDe (3.5c) W0 = Original weight of the MCS samples; WDe = Depleted Weight of MCS metal samples Kse& Kfi = Second and first order corrosion rate constant 3.3.5 Temperature Effect on Corrosion of the Metal Sample in the Corrodent Medium 3.3.5.1 Arrhenius Equation – Evaluation of Activation Energy Arrhenius equation is an empirical chemical equation that requires the temperature dependence of rates of reaction. It is extremely valuable in models like temperature variation of diffusion coefficients, population of crystal vacancies, creep rates & other heat/temperature (thermally) regulated/induced processes. Activation energy describes the fraction of species with energy greater than activation energy. In determining the adsorption free energy, the crude extracts were added into different sample bottles containing the electrolytic corrodent: 1.0M HCl solution. Then the metal sample (coupon) was incubated wholly and completely suspended in the corrodent mixture for a known retention time and temperature. Afterwards the MS metal sample is washed with running tap water. The metal sample is degreased through washing in a solvent – ethanol. Finally acetone washed and dried in warm air current – Digital Memmert Oven preferably for a known period of time at a particular temperature. After which the weight loss, surface coverage and other relevant values 48 were determined. From the resultant graphs plotted using Arrhenius equation estimates of change in the free energy of activation – activation energy was estimated using its slope and the pre-exponential constant was estimated using its intercept on the y-axis. The Arrhenius equation is stated mathematically below: CRK = K0exp ( ) ( ) -AE -AE or lnCRK = lnK0 + RT RT (3.6) Where: -AE = Slope; R lnK0 = intercept on the y - axis (3.7) K0 is the non temperature denpedent pre - exponential factor; T = Absolute temperature CRK = Corrosion Rate Constant of inhibition, R = Ideal/universal gas constant From Equation 3.11, activation energy (AE) values were calculated using the straight line regression between InCRK versus () 1 (Izionworu et al., 2020). T ° From Erying-Polanyi equation, the change in standard state activation enthalpy (∆Hact) ° and entropy (∆Sact) were evaluated using Equation 3.16 & 3.17. The corresponding Gibb free energy of activation at standard state was evaluated from the values of activation enthalpy and activation entropy when substituted properly at the relevant temperature using Equation 3.13 (Izionworu et al., 2020). 3.3.5.2 Erying-Polanyi Equation – Evaluation of Activation Enthalpy and Entropy The Gibbs free energy foretells whether a process is thermodynamically possible or not – The change in the standard state Gibb’s free energy for any chemical reaction 49 predicts the likelihood of that chemical reaction occurring or not. The more negative the value of the standard state Gibb’s free energy the higher the propensity for the chemical reaction to take place. Chemical reactions take place in the direction that reduces the Gibb’s free energy. A large negative value of standard state Gibb’s free energy may or may not be followed by a high rate of corrosion. If the standard state Gibb’s free energy has a negative value, the rate of chemical reaction may be fast or slow based on numerous factors. The activation energy was evaluated using Equation 3.10. Equation 3.10 is known as Eyring – Polanyi transition state equation its slope was used to evaluate activation enthalpy– Equation 3.11. Its intercept was used to evaluate activation entropy of the corrosion process– Equation 3.12. ∆Gact = (∆Hact) - T(∆Sact) ° ° ° (3.8) Where: ° ' ∆Gact = Change in standard state Gibb sfree energy of activation (∆S°act) = change in the standard state entropy of activation (∆H°act) = change in standard state enthalpy of activation;T = Absolute Temperature 0 0 0 ∆Gads. = ∆Hads. - T∆Sads. (3.9) 0 ° A graphical representation of ∆Gads.against Temperature; gives Slope = -∆Sads.; ° and Intercept on the y - axis = ∆Hads.; where:ads. = adsorption Equation 3.15, Eyring-polanyi equation is an equation based on statistical mechanical justification that describes the changes in the rate of a chemical reaction against the temperature of the reaction mixture. It is very useful in the transition state theory. It is also known as activated-complex theory. 50 ( ) ( ) 0 K= ° ∆Sact. RT -∆H exp exp or N*h R R*T () ( ) (( ) 0 KB ∆S0act. ∆Hact. K ln =+ ln + h T R*T R Where: ) (3.10) (Izionworu et al. 2020; Umoren et al. 2018) 0 ∆Hact. = standard state enthalpy of activation;R = Ideal/universal gas constant 0 ∆Sact. = standard state entropy of activation;T = absolute temperature K = Reaction Rate constant KB = Boltzmann constant = 1.380649x10 -23 2 -2 -1 m kgs K ; Note that R=NKB 23 ' N = Avogadro s No. = 6.022141 x10 Particles/mol -34 2 -1 h = Planck constant = 6.6242 ± 0.0044 x 10 m kgs (Joule second) ln A plot of () CR T () 1 T shows that: ( ) 0 -∆Hact. (i) Slope = R (3.11) [ ( ) ( )] 0 ∆S (ii) Intercept = ln R + act. N*h R (3.12) 3.3.6 Evaluation of Adsorption Isotherm Models Adsorption isotherm is a plot that often represents the change in the amount of a gas 51 adsorbed by the adsorbent with pressure at constant temperature. There are so many adsorption isotherms in describing the models that best fits adsorption process at equilibrium after experimental analysis. From cited literatures, some of the adsorption models used is Langmuir Model, Temkin Model, Freundlich Model, Floryhuggins Model, frumkin Model, el-awady Model (Alan & Araceli, 2020). The experimental results obtained in the gravimetric analysis were fitted into four different adsorption isotherms models namely: Langmuir, Temkin, Flory-Huggins, Freundlich isotherm models to see which one best describes the adsorption portrayed by EG plant extract on MS metal samples. Langmuir Model: Cinhibitor 1 = + Cinhibitor SC kads (3.13) Temkin Model: SC = ln Cinhibitor + kads (3.14) Flory-Huggins Model: ln SC CInhIbitor = bln(1-sc) + lnkads (3.15) Freundlich Model: ln(SC) = n ln(CInhibitor) + lnkads (3.16) Where SC = the surface coverage 52 3.3.7 Evaluation of Adsorption Parameter Gibbs free energy of corrosion of medium mild steel in the corrodent mixture: Equation 3.17 was used to evaluate the corresponding values of the Gibbs free energy associated with the corrosion of the MS metal samples incubated wholly & completely immersed in the corrodent mixture – 300mls volume combination of 1.0 molar concentration hydrochloric acid and plant extracts having deduced the adsorption rate constant from fitting experimental data into adsorption isotherm model which in this case Langmuir Model best describes adsorption of water soluble phytochemicals compounds with great affinity for MS metal samples. The following adsorption parameter: enthalpy, entropy and activation energy of adsorption was calculated using Equations 3.10, 3.11, 3.12 & 3.14. 3.3.7.1 Adsorption Free Energy The adsorption free energy was evaluated using equation 3.17. The crude extracts of different volumes were added into different sample bottles containing also different volumes of the electrolyte (1.0M HCl solution). Then the medium mild steel metal samples (coupon) was suspended completely and wholly incubated in the corrodent mixture and afterwards cleaned with tap water, ethanol, and acetone respectively and dried in a Digital Memmert oven for a known period of time at a particular temperature (50℃). After which the weight loss, surface coverage and others necessary values were calculated. From the ensued graphs plotted, the adsorption rate constant was estimated hence the change in the Gibbs free energy of adsorption at standard states was evaluated with the following equation below: 0 ∆Gads = -RTln(55.5Kads) (3.17) 53 Where: R = Universal gas constant;T = Absolute Temperature Kads = the binding constant or equilibrium constant of adsorption Process (Verma & Khan, 2016) 55.5 = water solution concentration in mol/L (Izionworu et al., 2020) 3.3.7.2 Evaluation of Adsorption Activation Energy, Enthalpy, and Entropy Plots of Gibbs free energy of adsorption against temperature of adsorption gives a slope whose numerical value is the entropy of adsorption and the intercept on the yaxis gives the enthalpy of adsorption of the molecules of the test inhibitor on the MS metal samples surfaces 3.3.8 Plant Extract Volume Effect This investigates the effect contributed by variation in volume of the hexane-based plant extract to the hydrochloric acid complementing volume in the corrodent mixture. Different volumes of Elaeis Guineensis hexane-based plant extracts added to dilute hydrochloric acid corrosive agent introduced some volume effect. Higher volumes of the test inhibitor caused more inhibition to metal samples corrosion rate literatures reveal. This implies constant concentration or content in mass composition of the dissolved pulverized plant sample as volume of the test inhibitor used in the corrodent mixture is altered increasingly or otherwise. This is different from the effects created as a result of increasing the quantity of already dissolved powdered test inhibitor in mils – constant concentration. No mathematical relationship has been used by previous literature in this regard increasing volume of the test inhibitor on green inhibitors as corrosion rate inhibitor of metals samples in 54 acidic medium except plots of reaction rates against volume of the test inhibitor used in the corrodent mixture. 3.3.8.1 Mild steel – FTIR Analysis of MS Metal Samples Surface The spectra for the protective thin layer on MS metal sample surface after 9.00hrs of wholly & completely suspended incubation in the control/blank experiment, and a mixture of 1.0M HCl and test inhibitor in varying complimentary volumes was recorded by directly beaming the thin film on surfaces of the MS metal samples. This identified the likely molecular phytochemical components of the test inhibitor adsorbed to the metal samples surfaces. The Apodization equipment: Happ-Genzel by Agilent Technologies spectrophotometer has the capacity to identify components on metal samples surfaces. This is as reported by the operator of the device in question in Katsina State, Nigeria. 3.3.8.2 SEM Analysis of Medium Mild steel Metal Surface Scanning Electron Microscopy studies of the effect of corrodent mixture caused on medium mild steel metal samples as morphological investigations of the microsurface of the medium mild steel after 9.00hrs immersion incubation in the corrosive mixture with or without the test inhibitor was carried out using Scanning Electron Microscopy examination of the electrode surfaces exposed to the different test solution using XL – 30FEG scanning electrode microscope (Sangeetha et al. 2020). Medium mild steel samples were suspended incubated wholly & completely in 1.0M HCl solution as blank and in 1.0M HCl solutions containing appropriate complementary volumes of the test inhibitors. After 9.00hrs, the MS metal samples were withdrawn and subjected to Scanning Electron Microscopy technique for surface structure analysis (Izonwuru et al., 2021). The 9.00hrs used medium mild steel samples M, J, O, and L 1.0 molar concentration HCl solution were subjected to 55 scanning electron microscopy. This would possibly enable us to visibly perceive patterns established on the mild steel samples as a result of experimentations using the two extracts in a 1.0 molar concentration HCl corrosive medium. 56 CHAPTER 4 RESULTS AND DISCUSSION 4.1 Composition of Mild Steel Mild steel typically contains up to 0.25% carbon content (Singh, 2020). The sample of mild steel analysed had a carbon content of 0.18%. With manganese content ranging from 0.5 to 1.0%, mild steel can be strengthened through heat treatment, however it is less responsive than higher Mild Steels. The density of the mild steel sample was measured to be 7.85 g/cm3, very close to pure iron's density of 7.874 g/cm3 (Llewellyn & Hudd, 1998). This matches expectations, as mild steel contains mostly iron with very low alloying content. A specimen was machined from a mild steel channel with total surface area calculated to be 30cm2 using standard geometric equations. A small hole of diameter 0.25 cm was drilled, giving a hole, area of 0.05 cm2. This hole enabled suspending the specimen in corrosive media using a plastic tie thread. Mild steel has wide applications owing to its relatively low price and easily machinable nature. Common uses include structural shapes, gears, shafts, magnets and automobile parts. It can readily be welded and formed. Heat treatment can augment its hardness and strength moderately depending on needed mechanical properties (Totten et al. 2016). Mild steel performs adequately across a range of engineering requirements while avoiding the extra cost of specialized alloys. 57 Table 4.1 chemical composition of mild steel sample Element Mild Steel Composition (%) C 0.134 Si 0.119 Mn 0.237 Mo 0.083 Co 0.012 Al 0.050 Cu 0.044 Nb 0.108 Sn 0.046 Ni 0.019 Cr 0.094 Fe 98.80 4.2 Plant Extracts Characterization In the preparation of the plant extract – Table 3.1, 3.2, 3.3 & 3.4, it was found that 1.29g of Elaeis guineensis, EG powder completely dissolved in 1000mls of hexane extractive solvent hence its mass concentration measured in 64.5g/L. A variant from the customary route of acid dilution in the laboratory involved a direct dilution of the concentrated hydrochloric acid with varying mls of plant extract plus 500mls of water to make 1000mls like water acid dilution or 300mls of the hexane-based plant extract only was adopted to answer the question, “What if in cases where the concentrated hydrochloric acid or its dilute in higher concentrations greater than 1.0 molar concentration is required in cleaning of surfaces, pigging of pipelines, or oil 58 well stimulation?” There is one (1) hexane-based plant extracts. Made from Elaeis guineensis EG. The following is the characterization result and discussion. 4.2.1 Gas Chromatography/Mass Spectrometry, GC/MS of the Powdered Plant Sample The results of gas chromatography – mass spectrometry of the plant made from dried powdered Elaeis guineensis EG, plant is shown below: Table 4.5.. Table 4.2. This is a GCMS technique phytochemical quantification summary report of Elaeis guineensis, EG – prepared powdered sample is majorly composed of, phytochemical profile showed the presence of a variety of compounds including: Fatty acids: Oleic acid (47.25%), Linoleic acid (15.31%), Palmitic acid (9.32%) and Stearic acid (6.21%). Phenolic Acids: p-Coumaric acid, Caffeic acid, Ferulic acid. Flavonoids: Catechin and Epicatechin. Sterols: Campesterol, Stigmasterol, βSitosterol. Other compounds: Tocopherols, Tocotrienols, Glycerol and Phthalic acid derivatives. The major components were the fatty acids, especially unsaturated oleic and linoleic acids. Phenolic acids and flavonoids were also present which contribute to antioxidant potential. Phytosterols and vitamin E isoforms also provide various health benefits. The extract displayed a broad diversity of natural compounds with nutritional and potential biological effects. Past work on green inhibitor have established molecular phytochemicals components capability in corrosion rate inhibition of metal samples in contact with corrosive environments. Extensive literature review, research have shown that these molecules and hence functional group are capable of inhibiting the rate at which 59 corrosion takes place on metal surfaces in acidic and other media where the use of metals and other substances that rust or corrode are inevitable (Izionwuru et al. 2021; Oguzie, et al. 2013; Umoren 2015; Hussaini et al. 2020). Figure 4.1, 4.2, 4.3, 4.4 is a representation of the structural & molecular formula of molecules and associated functional groups contained in the hexane solvent extract of Elaeis guineensis EG plant. Here are the molecular formulas and structural formulas for some of the main functional groups identified in the palm bunch spikelet extract from the GC-MS results: Fatty Acids: Oleic acid Molecular formula: C18H34O2 Structural formula: Linoleic acid Molecular formula: C18H32O2 Structural formula: 60 Fig 4.1 Linoleic acid Phenolic Acids: p-Coumaric acid Molecular formula: C9H8O3 Structural formula:Caffeic acid Molecular formula: C9H8O4 Structural formula: Fig 4.2 Phenolic Acids Flavonoids: Catechin Molecular formula: C15H14O6 Structural formula: Epicatechin Molecular formula: C15H14O6 Structural formula: 61 Fig 4.3 Flavonoids Sterols: β-Sitosterol Molecular formula: C29H50O Structural formula: 62 Fig 4.4 Sterols The structures show the different functional groups like hydroxyl, carboxylic acid, aromatic rings, and alkene groups that contribute to the unique properties and bioactivity of the many different compounds identified in the palm bunch spikelet extract through GC-MS analysis. Table 4.2 Summary of Phytochemical Quantification Report of Powdered Spike Moss Sample 63 4.2.2 Fourier Transform Infrared Spectroscopy Figure 4.5 is the spectra that resulted from the characterization of hexane-soluble components contained in the prepared EG plant extract using Fourier transform infrared technique. This clearly shows the infrared spectrum of EG plant extract. Also, the spectra peaks, compound class, and functional groups of the extracts were determined based on the interpretation of the FT-IR spectrum of extracts using standard chart. Thus, the results of the absorption (peaks) revealed the possible functional groups of the spectrum. This revealed that the extracts contain compounds such as carboxylic acid, esters, aldehydes, aliphatics, amines, aromatics and phenol. Heteroatoms like oxygen, nitrogen, sulphur and double or multiple bonds are contained in these compounds. Thus, these deductions are in accordance with previous study of El-Nemr et al., 2014, chioma et al., 2022, Eno et al., 2018 etc that recognizes the presence of these compounds and others in crude extracts to inhibit the rate of corrosion of metals in an acidic or salty (corrosive) environment. Ogunlaye et al., (2020) on FT-IR analysis reported that the existence of phytochemical molecular compositions having nitrogen- and/or oxygen- that is, hydroxy aromatic compound, for example, tannins, flavonoids, pectins, etc. including components of green nature origin in extract hence confirmed the extract metal corrosion inhibitor. Furthermore, the FT-IR characterization of the test inhibitors showed all the peaks and different wave numbers of molecules contained. The peaks were used to identify the possible functional groups of the compounds in the crude extracts. The results of the characterization of the test inhibitor extract using FT-IR are shown in Table 4.6; while the FT-IR spectra, compound class, functional group and appearance for each plant extract are highlighted in Table 4.2 and Table 64 Figure 4.6 FT-IR Spectrum of EG Plant Water based Extract phytochemical composition 4.3 Calcuulated Test Inhibitor Performance 4.3.1 Weight Loss From the rate of corrosion equation, Equation (3), the rate of corrosion of a corrodible material is directly proportional to weight loss in a corrosive environment. From the graphs plotted, Weight Loss (mg) versus Temperature (K), Weight Loss (mg) versus Time (hr) for Mild Steel Corrosion in 1.0M HCl, it can be deduced that the above proposition for the control experiment was completely true; but for the corrosive medium where EG plant extracts occupied however to a higher percentages, an effect which censored this “directly proportional” relationship into something less. This proves the inhibitive effects posed by the mere presence of EG plant hexane-based extract by formation of thin film which blocked the active cites where corrosion takes place on the surfaces of the Mild Steel metal samples. This fact is presented in the following figures: Figure 4.7A. Very clearly from plots, it can 65 be deduced that samples with some volumes of the test inhibitor tolled a similar pattern as the control experiment (blank) – increment in the weight loss as the experiment proceeds in hours although values not as large as when compared with Blank C samples weight loss values (Figure 4.7A). The temperature experiment (Figure 4.7B), the corrodent mixture containing some volumes of test inhibitor followed paths almost parallel to the temperature axis (little deviation from samples like corrodent Sample B in Figure 4.7B) implying more significant reduction in the weight loss on the MS metal samples as temperature of the corrodent medium is raised little above the room temperature. This proves that although there was an effect – undulating pattern or inflexion points created by the presence of the test inhibitor in the corrodent mixture but the corrosive acid in the medium could still overcome the thin film protection of the test inhibitor on the metal surfaces which in many cases interacts with the metals atoms to attack the metal samples but in a very minimal mannered way when compared with the effect posed by Blank C sample. 0.08 weight loss in (mg) 0.07 0.06 0.05 Wloss I(50)H 0.04 Wloss N(100)H 0.03 Wloss K(150) H 0.02 Wloss C(300) 0.01 0 0 20 40 60 80 100 120 140 Time in (hr) Figure 4.7A Weight Loss (mg) versus Time (hr) for MS metal samples corrosion rate inhibition in complementary presence of vary volumes of EG plant extract & 1.0 Molar concentration HCl corrosive solution at room temperature & different immersion time 66 0.09 0.08 Weight Loss (mg 0.07 0.06 0.05 Wloss M (50) 6 H 0.04 Wloss J(100)6h 0.03 Wloss L (200) 6 H 0.02 Wloss C(300)6h 0.01 0 300 305 310 315 320 325 330 335 340 345 Temperature (K ) Figure 4.7B Weight Loss (mg) versus Temperature (K) for MS metal samples corrosion rate inhibition in complementary presence of vary volumes of EG plant extract & 1.0 Molar concentration HCl corrosive solution at constant retention/immersion time – 6.00hrs 4.3.2 Corrosion Rate It is known from thermodynamics that increase in temperature of a system increases molecular activities, that is, the average kinetic energy of a system is the measure of its absolute temperature in Kelvin. According to Van’t Hoff, in physical chemistry, an increase in temperature will cause an increase in the rate of endothermic reactions. Also, that increases in temperature of a system by 10℃ doubles the rate of reaction. The rate of corrosion of Mild Steel in 1.0M HCl is no exception of these statements. From the graphs plotted, Corrosion Rate (mm/yr) against Temperature (K), Corrosion Rate (mm/yr) against Time (hr) for Mild Steel Corrosion in 1.0 HCl, it can be deduced that the above proposition for the control experiment was completely true for all temperature at immersion times of 3.00hrs, and 6.00hrs until at 9.00hrs immersion time at temperatures above 333K a decrease in corrosion rate was observed for almost all samples of the corrodent mixture possibly due to scale formation (Ueda et al., 2006) – decrease in surface area of the 67 Mild Steel available for corrosion attack since surfaces in contact were already corroded and full of dirt (Izionwuru 2020) and possible decomposition of the active principles of the test inhibitors (Giwa et al., 2020). The corrodent medium having different volume composition hence different surface coverage of EG or in little or high percentage followed a different path from that of increase in temperature & increase in rate of reaction/corrosion. These facts proves that the presence, of the EG plant hexane-based extract exacted some effect on the rate of reaction/corrosion of medium Mild Steel samples in 1. molar concentration hydrochloric acid due to ability of the extracts to inhibit metal corrosion by formation of thin film barrier on the surfaces of MS metal samples. This fact was simplified in plots of corrosion rate against volume of the test inhibitors used in each corrodent complimentary mixture as typified in volume effect of test inhibitors in the corrodent medium – Subheading 4.3.8. The corrosion inhibition components or molecules in the hexane-based extracts blocked the active sites prone to corrosion effects. This fact is presented in Figure 4.8A and 4.8B. From the plots key, the numerical values in the brackets show the percentage in volume of the test inhibitor in the 300mls corrodent mixture. The control experiment – Sample C has 0%, Sample I, J, K, L, M, N has varying. volume compositions of the test inhibitor. These figures visibly deduced that the test inhibitions characteristic trend followed by the control experiment portrayed similar path as the other samples but this time in an undulating –manner having points of inflexion pattern along the x-axis either for temperature or retention time indicating that although there was corrosion rate inhibition but the corrosive acid in the medium ever struggles in a partial successful breaking maybe due its high molar concentration through the inhibition molecular component thin film barrier formed on the metal surfaces. 68 Corrosion Rate (mm/year) Chart Title 1.2 1 0.8 CR,I (50ml) 0.6 CR, N(100ml) 0.4 CR, K(150ml) 0.2 CR,Kwot(300ml) 0 0 20 40 60 80 100 120 140 Time (hr) Corrosion Rate (mm/year) Figure 4.8A Corrosion Rate (mm/yr) against Time (hr) for MS metal samples corrosion in complementary presence of vary volumes of plant extract & 1.0 Molar concentration HCl corrosive solution at room temperature and different immersion Time Chart Title 7 6 5 4 CR, M6h(50mls) 3 CR,J6h(100mls) 2 CR, L6h200mls) 1 W0(300mls) 0 300 305 310 315 320 325 330 335 340 345 Temperature (K) Figure 4.8B Corrosion Rate (mm/yr) against Temperature (K) for MS metal samples corrosion in complementary presence of vary volumes of EG plant extract & 1.0 Molar concentration HCl corrosive solution at constant retention/immersion time – 6.00hrs 4.3.3 Inhibition Efficiency It is a known fact that in the study of the graph of inhibition efficiency against temperature for metals in corrosive environment, for example, Mild Steel corrosion in I.0M HCl solution in the presence of different concentrations of organic extract shows that as the concentration of organic extract increases, thus inhibition 69 efficiency IE% increases (Singh et al., 2010). It had also been proven that slight increase in temperature, increases the inhibition efficiency, IE% for all optimum concentration of organic extract inhibitors and shows a slight drop in IE% as temperature increases further since at certain temperature dependent on the organic composition of the extract, dissociation of molecules sets in (Alan and Araceli, 2020). Inhibition efficiency against sustained time, and temperature for Mild Steel corrosion in 1.0M HCl at different volume concentrations of EG plant extract and temperatures at either constant (room temperature) or changing time (3.00, 6.00, and 9.00hrs), it can be deduced that some volume concentrations of EG extract responded to temperature in accordance to inhibition efficiency decrease after initial stability at temperatures below 313K at 6hrs immersion time. Other volume concentrations of EG sustained increase in temperature as their inhibition efficiency kept increasing up to 343K at 9hrs sustained immersion time after which their inhibition efficiency dropped in all the corrodent samples, in some cases slightly and others pronounced, predicting the possible maximum temperature and sustained immersion time before which EG hexane-based extract can no longer sustain inhibition possibly due to dissociation of those extract components responsible for inhibition as reported by Alan and Araceli, (2020). The length of time (immersion time) affected the inhibition efficiency, in particular at room temperatures (Figure 4.9A) where MS metal samples were wholly and completely immersed suspended incubated in the corrodent mixture for five (5) days. It can be deduced from plots that at about 60 hours of immersion time, inhibition efficiency of corrodent samples performance profile (Figure 4.9A) started decreasing, maybe due to deterioration of the hexane-made sample of EG as reported by Alan and Araceli, 2020. These facts are presented in Figure 4.9A. The temperature study (Figure 4.9B of the performance of the test inhibitors, it can 70 be seen that at 6.00hrs immersion time, and temperatures of 343K performance profile of some corrodent mixture (for example, SAMPLE B 4.9B,) started going back down to the temperature axis – decrease in inhibition efficiency values after its initial upward increment in the values of inhibition efficiency at temperatures less than 343K. This can be attributed to the acid content in the corrodent mixture over powering the barrier on the metal sample as formed by molecular components of high affinity for MS metal samples surfaces possibly due dissociation or breaking down of this molecules and lower volume of the test inhibitor in a corrodent sample when compared to that of the acid – volume, molar concentration and temperature effect of the test inhibitors, thus leading to once again sequel increments in the values of corrosion rate. 100 90 Efficiency, IE% 80 70 60 50 IE,I(50mls) 40 IE,N(100mls) 30 IE,K(200mls) 20 10 0 0 20 40 60 80 100 120 140 Time (hrs) Figure 4.9A Inhibition Efficiency, IE% against Time (T/hr) for MS metal samples corrosion rate inhibition in complementary presence of vary volumes of EG plant extract & 1.0 Molar concentration HCl corrosive solution at room temperature & different immersion time 71 450 400 Efficiency, IE% 350 300 250 IE,M(50)9h 200 IE,J(100)9h 150 IE,L(200)9h 100 50 0 300 305 310 315 320 325 330 335 340 345 Temperature, T(K) Figure 4.9B Inhibition Efficiency, IE% against Temperature (T/K) for MS metal samples corrosion in complementary presence of vary volumes of EG plant extract & 1.0 Molar concentration HCl corrosive solution at constant retention/immersion time – 9.00hrs 4.3.4 Kinetic Parameter – Corrosion Rate constant It is generally known that first order chemical reactions occur faster than second and third order chemical reactions. Second order chemical reactions occur faster than third order chemical reactions (Levenspiel, 2004). This is as showcase in the table of corrodent mixture samples at different temperatures. At a particular temperature and different equal time interval of the reaction in hours there exists a rate constant for the chemical reaction. The rate constant at higher volumes of the test inhibitor moved from second order to first order as reaction temperature increases. This is to say and validate that reaction rate increases in linearly, power order, or exponentially with reaction temperature Figure 4.10A & Figure below. These figures describe the path followed by the corrosion reaction rate constant as system temperature increases. Corrodent samples A, B,& E had similar trail more the kinetic rate constant path of sample C, the blank corrodent sample, although are of different kinetic order 72 with sample C. Sample C is more of first order kinetic reaction - faster occurring reaction than second order reactions. In the first case of second order chemical reactions, typified by Equation 3.12, this is as a result of the presence of the test inhibitor which decreased the rate of corrosion of the MS metal samples in the corrodent mixture. But it is known also that the rate of chemical reaction reactions increased with increase in temperature and in line the dissociation, decomposition or breaking down of the test inhibitor molecules as a result of higher temperatures compatibility in some corrodent sample cases at 313K and others at 343K. At temperatures greater than these, dilute hydrochloric acid attacked MS metal samples in the corrodent mixture with little or no obstructive barrier induced by the presence of the broken-down test inhibitor molecules in the experimental medium. This escalated the rate constant from second order to first order chemical reaction rate constant. This clearly shows and proves that indeed there was an increase in rate of corrosion reaction on the metal surfaces exposed to dilute hydrochloric acid attack in the corrodent mixture. This movement in the values of rate constant occurred in the corrodent medium containing partial volume of Elaeis guineensis, plant extract – coloured values in the rate constant table 73 Corrosion Rate Constant, K (1/hr) 0.166 0.164 0.162 0.16 1/Wde 9h y = 0.0001x + 0.1226 0.158 1/Wde 9h 1/Wde 9h 0.156 Linear(1/Wde 9h) 0.154 0.152 300 305 310 315 320 325 330 335 340 345 Temperature, T (K) Figure 4.10 Variation of Corrosion Rate constant against temperature for MS metal samples incubated in Complementary volumes of EG Plant Extract & 1.0 molar concentration hydrochloric acid corrosive medium at different temperature 4.3.5 Temperature Effect 4.3.5.1 Arrhenius Equation This relationship clearly states that the natural logarithm to rate constant, lnK when plotted against the reciprocal of the temperature in Kelvin scale gives activation energy as the slope and frequency factor as intercept on the y-axis. Several researchers on this concept “green inhibitor” for safe environment, biological life inclusive have each time temperature relationship arise adopted corrosion rate values for reaction rate constant without stating reasons for such condition. Such thing is not true. Reaction rate constant is different from rate of reaction. They are two different things which are related in chemical reaction kinetics (Levenspiel, 2004). Arrhenius equation accounts for the effects or impact of temperature over the rate at which a chemical reaction occurs. This impacts of temperature are depicted in Figure 4.11A Corrosion & principles of corrosion obey and follow the path of 74 chemical reaction. The value of activation energy tells if the reaction will be slow or fast because until the energy of the molecules is equal or greater than that of the energy barrier value the will be no effective collission hence the reaction can not occur (Schweitzer, 2010; Husaini et al., 2020). Thus, high activation energy means high energy required to have a successful collision between the particles. The particles gain enough energy from heat to overcome the barrier of activation energy, the minimum extra amount of energy required for any chemical reaction to proceed/take place. Negative activation energy suggests that the permeance of the components decrease with temperature while the partial flux increases normally with temperature. Figure 4.11A represent Arrhenius plot depicting the effect of temperature on the rate of corrosion of MS metal samples in 1.0 molar dilute hydrochloric acid. -9.1 0.00295 0.00305 0.00315 0.00325 0.00335 0.00345 -9.6 lnK -10.1 -10.6 -11.1 -11.6 -12.1 1/T (1/K) Figure 4.8b Natural logarithm to Corrosion Rate against reciprocal of Temperature (T/K) for MS metal samples corrosion rates in complementary presence of vary volumes of EG plant extract & 1.0 Molar concentration HCl corrosive solution 75 4.3.5.2 Eyring-Polanyi Equation The properties to be determined are activation energy, activation enthalpy, and activation entropy. From the understanding of thermodynamics, entropy means the degree of randomness/disorderliness of a system. A positive entropy change means an increase in disorder. The universe tends toward increased entropy. All spontaneous change occurs with an increase in entropy of the universe. The sum of the entropy change for the system and the surrounding must be positive for a spontaneous process. In all chemical reactions, including exothermic reactions, activation energy is needed to get the reaction started. Activation energy is needed so reactants can move together to overcome forces of repulsion and start breaking bonds. From the graphs, the evaluation of activation energy was carried by plotting natural logarithm of rate of corrosion against temperature whose slope when compared with Arrhenius equation - equation (9), an equation that represents the effects of temperature on the velocity of a chemical reaction estimated both the activation energy and the exponent of the intercept on the vertical axis (y-axis), the pre-exponential factor. Activation energy is that minimum amount of energy that molecule(s) must have before a reaction can take place. With this in our hearts, it is worthy of note that if this minimum amount of energy is very high, the chemical reaction may not take place or it will a take a longer time to accumulate that quantity of energy requirement hence the chemical reaction may be very slow. On the opposite, if the energy is low enough the chemical reaction occurs faster because it takes a very short time to attain such minimum amount of energy. The activation energy requirement or barrier must be attained by the molecules before any chemical reaction will takes place. In order to evaluate activation enthalpy, entropy, & corresponding Gibb free energy, 76 Eyring-Polanyi transition state equation – Equation 3.15 was used. The plot of the natural logarithm of rate of corrosion/temperature against reciprocal of same temperature gave rise to a graph whose slope necessitated estimation of the enthalpy and its intercept on the y-axis, the degree of randomness or disorderliness, entropy. Figure 4.12A represent Eyring-Polanyi plot depicting also the effect of temperature on the rate of corrosion of MS metal samples in 1.0 molar dilute hydrochloric acid (Appendix K & L). All the deduced entropy values were all positive values (depict change in entropy greater than zero) and Gibbs free energy were all negative (less than zero) implying spontaneous process at 297K and temperatures greater than 273K. -14.5 0.00295 0.00305 0.00315 0.00325 0.00335 0.00345 -15 in (K/T) -15.5 -16 -16.5 -17 -17.5 -18 1/Temperatue (1/K) Figure 4.12A Natural logarithm of the Quotient of Corrosion Rate Constant (K) and Temperature (T/K) against the Reciprocal of same Temperature (T/K) for MS metal samples corrosion rate in complementary presence of varying volumes of EG plant extract & 1.0 Molar concentration HCl corrosive solution 4.3.6 Adsorption Isotherm Model Study of the Test Inhibitors 77 Langmuir proved that there exists a relationship between concentration in grams of dissolved particles in a solution and its adsorption efficiency on a metal surface – Equation 3.13, equation of a straight line when linearized. Mass of dissolved EG dried sample accounts for the concentration of the extracts’ complementary volume, Cinh (g) in the 300mls corrodent volume. The mass of dissolved test inhibitor, Cinh (g) in the corrodent mixture depends on the mass of test inhibitor in g/dm3 in prepared volume of the plant extract. Hence, Cinh (g) is a measure of volume of the prepared extract. Plots of Langmuir Isotherm for EG plant extract active molecular components adsorption on MS metal samples in varying volume of 1.0M HCl solution at various immersion times (hrs) and constant temperatures (K) are schematically demonstrated below in which the quotient of concentration of the test inhibitor and its surface coverage is plotted against the same concentration of the test inhibitor (mass of the test inhibitor dissolved in the corrodent medium). This plot estimated the adsorption constant Kads of the active molecular compounds on the MS samples hence estimates the Gibbs free energy of adsorption whose plots against absolute temperature estimated the enthalpy and entropy of adsorption of active capable compounds of the prepared extract all at standard states (Figure 4.13A & 4.13B). The figures predicting adsorption rate constant, Kads of active capable molecular compounds for EG prepared extract on MS metal samples is given in (Figure 4.13A & 4.13B) are tables for the plots Gibbs free energy against temperature whose slope and intercept estimates adsorption entropy and enthalpy were in accordance with Equation 3.9. Adsorption rate constant, Kads values are greater than zero, that is, large values of K implying effective/significant adsorption of active capable test inhibitor phytochemical molecular components with great affinity for MS metal sample surfaces. These values of Kads also quantifies the 78 magnitude content strength holding together the surfaces available resulting to good inhibition efficiency (Umoren et al., 2018). y = 0.8586x + 1.8092 R 2 = 0.9179 5.2 5 CINH, L/SC,O 4.8 y = 0.6628x + 2.0479 R 2 = 0.9467 4.6 4.4 y = 0.9354x + 0.9934 R 2 = 0.9039 4.2 y = 0.8233x + 1.4758 R 2 = 0.9984 4 3.8 3.6 2.7 2.9 3.1 3.3 3.5 CINH, L(G) 3.7 3.9 4.1 Figure 4.13A Plots of Langmuir Isotherm for corrodent Sample O (prepared EG plant extract containing corrodent mixture) adsorption on MS metal samples at constant temperatures (K) and different immersion/retention time (hrs) 79 2.71 y = 1.253x + 0.1611 R2 = 0.9854 CINH, M/SC, M 2.51 y = 0.8619x + 0.9411 R2 = 0.9901 2.31 y = 1.308x + 0.0976 R2 = 0.9961 y = 1.2461x + 0.0443 R2 = 0.9887 2.11 1.91 1.71 1.35 1.45 1.55 1.65 1.75 CINH, M (G) 1.85 1.95 2.05 Figure 4.13B Plots of Langmuir Isotherm for corrodent Sample M (prepared EG plant extract containing corrodent mixture) adsorption on MS metal samples at constant temperatures (K) and different immersion/retention time (hrs) 4.3.7 Adsorption Parameter 4.3.7.1 Adsorption Free Energy Umoren et al., (2018) used the values of Gibbs free energy of adsorption in a comparative corrosion inhibition efficacy investigation study using ethanol and water as extraction solvents on Date palm leaves and seeds in 15% hydrochloric acid solution, and Mild Steel metal sample to imply whether an adsorption interaction was physical, chemical or mixed mode of adsorption. 4.3.7.2 Determination of Adsorption Enthalpy and Entropy of the Inhibitors Umoren et al., (2018) plotted the values of Gibbs free energy of adsorption against temperature in comparative corrosion inhibition efficacy investigation studies using ethanol and water as extraction solvents on Date palm leaves and seeds in 15% hydrochloric acid solution, and Mild Steel metal sample. Figure 4.14A is the plots of Gibbs free energy, J/gmol against temperature, K for the corrodent medium 80 containing in complementary volume, prepared or EG in which MS metal sample is wholly and suspended incubation. This predicts the change in enthalpy & entropy of adsorption of active capable phytochemical compounds that adsorbed on the MS metal samples in the corrodent medium containing 1.0 molar dilute hydrochloric acid. 2000 ΔGADS OF CORRODENT SAMPLES 0 300 305 310 315 320 325 330 335 -2000 -4000 -6000 -8000 -10000 -12000 -14000 -16000 TEMPERATURE (K) ° Figure 4.14A ∆Gads against Temperature (K) for extract of EG active molecular compounds adsorption on MS metal samples in I.0M HCl solution at different temperatures of 303K, 313K, 323K, 333K and 343K 4.3.7.3 Effect of Temperature on the Adsorption Rate Constant Temperature affects the rate of any chemical reaction hence its rate constant. This implies that at a particular temperature, the rate of reaction has a constant value called reaction rate constant (Levenspiel, 2004). The adsorption rate constant in different corrodent medium, samples A – O composed of different complementary 81 volume of prepared EG plant extracts & 1.0 molar hydrochloric acid solution in 300mls together in a container was plotted to visibly see its response to the applicable temperatures. This is as typified in Figure 4.15A & Corrodent medium sample H composed of 80% (300mls) 1.0M HCl & A 20% (50mls) prepared plant extract adsorption rate constant Kads, H responded to the applicable temperature in a negative quadratic equation dome – more of polynomial order. Corrodent medium sample A composed of 60% (150mls) 1.0M HCl & 40% (50mls) prepared plant extract also took a different trajectory from corrodent medium sample B. Corrodent medium sample L composed of 500mls hexane to 87.3mls concentrated HCl & 500mls prepared plant extract behaved differently as its values took almost a parallel path without any rise in value of adsorption rate constant throughout the applicable temperatures along the x-axes instead a decrease in value surged in. Others took similar trajectory almost parallel to the known x-axes which showed positive increment in the values of adsorption rate constant at temperature slightly above 321K. It can be deduced that the volume of the plant extracts directly affected the values of adsorption rate constant to temperatures slightly above 321K after which the adsorption rate constant values surged in a positive direction. This is in accordance with already established principle that at higher temperatures phytochemical of natural origin tend to dissociate and decompose making the active phytochemical metal adsorption composition unstable causing a reduction in corrosion inhibition capable molecular adsorption to metal surfaces as higher corrosion rate values have been observed at higher temperature, as revealed by extensive literature review. EG prepared plant extract containing corrodents’ samples had its own unique temperature response - Figure 4.15A. Corrodent sample D & F took differently their 82 trajectory. Corrodent sample E, H, B, G & A took similarly trajectory paths parallel to x - axes throughout the applicable temperature. 320 ADSORPTION RATE CONSTANT, K 270 220 170 120 70 20 295 -30 300 305 310 315 320 325 330 TEMPERATURE (K) Figure 4.15A Adsorption Rate constant against Temperature(K) for extract of EG active molecular compounds adsorption on MS metal samples in I.0M HCl solution at various temperatures of 303K, 313K, 323K, 333K and 343K. 4.3.8 Plant Extract Volume Effect on the Corrosion of MS Metal Samples 4.3.8.1 Effects of Volume of the Test Inhibitors used in the Corrodent Mixtures The plots of the rate of corrosion of medium Mild Steel against the volume of the test inhibitors used in 300mls of complementary presence of 1.0M HCl corrodent medium at room temperature and other temperatures like 30 – 700C and at different immersion times are shown in Figure 4.7A. The Figure 4.7A & Figure 4.7B is plots showing the response of varying volumes of Elaeis guineensis (stem & leaves) hexane extract on the rate of corrosion of medium Mild Steel in 1.0M HCl corrosive medium respectively at room temperature and different immersion times of 24, 48, 83 335 72, 96, and 120hrs. From the graphs, it can be deduced that all volumes of the test inhibitor EG all reduced Mild Steel corrosion initially to an extent as the corrosion rate took undulating nosedive in the direction of 300mls of the test inhibitor in 1.0M HCl. Relatively, it took some time again and again for the aggressive corrodent medium trying to overcome the barrier established by thin but protective film layer formed to corrode the metal, the molecules of the test inhibitor capable of adsorbing on the surfaces of the medium Mild Steel introduces this effect that dwindled to an encouraging extent the rate of corrosion on medium Mild Steel whose applications in areas where acid corrosion in surfaces due to cleaning and oil well stimulation are inevitable (Izionwuru et al., 2012). Having broken the barrier, higher rates of corrosion set in as the constant immersion retention time profile rises in corrosion rate values for the figures plots – Figure 4.7A & 4.7B. If no further volume of the test inhibitor is added, there may be a rise close to but never higher than the original position of 100% 1.0 Molar concentration HCl. As more volumes of the test inhibitor is added, a nose-diving effect on the rate of corrosion is continuously seen again and again in all the figure depicting high suppressive effect of the test inhibitor over the aggressive corrodent medium. This struggle of the acid in breaking the film barrier on the metal surfaces continues as the test inhibitor suppresses it all the time but not completely from attacking the metal from the surfaces (Madu et al., 2019). At higher temperatures plots, the addition of the test inhibitors performed significantly better possibly because of the short intermittent time of 3.00hrs, 6.00hrs and 9.00hrs at 303K, 313K, 323K, 333K and 343K than large expanse of time at 24.00hrs, 48.00hrs, 72.00hrs, 96.00hrs, and 120.00hrs at room temperature (Appendix O & P). 84 It can be deduced that increase in the volume of the test inhibitor decrease significantly the rate of Mild Steel corrosion in 1.0M HCl corrodent medium although there always exist a struggle from the acid side to oppose this effect as introduced by the presence of molecules with the ability of adsorbing on the medium Mild Steel as they collectively form a partial protective film layer on the metal surfaces. Some volumes of the test inhibitor functioned better than others at constant temperature and different immersion time or vice versa. 4.3.8.2 FTIR Metal Surface Analysis Figure 4.3 shows the FT-IR spectra of the Mild Steel after 9.00hrs of suspended immersion incubation, the thin film on the Mild Steel sample in Elaeis guineensis, plant extract/1.0M HCl solution corrodent medium, only two components were identified by the FT-IR device. This implies that some components physically adsorbed (physisorption) to form a protective film on the surface of the MS metal samples. That is to say that some of the adsorption occurred by physisorption. Presence of these components blocked the active site for corrosion thus protecting the metal from deterioration due to its presence in dilute hydrochloric acid environments. Gravimetric results and SEM analyses prove that adsorption occurred spontaneously on the surfaces of Mild Steel metals samples contained in the corrodent medium with EG plant extract. From Figure 4.16A, the FT-IR spectrum of 9.0hrs suspended immersion incubation of Mild steel surfaces in EG corrodent medium. The FT-IR device could not identify any component in the thin film on the surface of the medium Mild Steel sample. This quickly implies that the adsorption occurred through chemisorption rather than physisorption (Muthukrishnan et al., 2013) 85 Figure 4.16A FT-IR Spectrum of EG Plant Extract Molecules on the Surface of the Mild Steel 4.3.8.3 SEM Microstructure Analysis – Surface Morphology of Medium Mild Steel Metal Sample The test inhibitor is referred to as Elaeis guineensis. Scanning Electron Microscopy (SEM) microstructure surface examination technique was used for surface characterization of the MS metal sample before and after immersion for 9.00hrs at room temperature in a solution of 1.0M HCl as corrodent solution at maximum (80%), minimum (20%) volume concentrations of EG plant extract and in complete absence of the test inhibitors – Control/Blank C are presented in Figure 4.17A. A fresh medium Mild Steel metal sample surface was also characterised and its result was used as a standard to compare, contrast and compute damage extent induced by dilute hydrochloric acid in the corrodent mixture. These results show that in a complete absence of the test inhibitors in the corrodent mixture, 1.0 molar concentration dilute hydrochloric acid, the Mild Steel surface was seriously battered and damaged as hole, pits and cracks are very visible (see Figure 4.17B). The extent of the damage was progressively dependent on the volume of the test inhibitors in 86 the corrodent medium (see Figure 4.17C). This battered surface could be attributed to the metal samples dissolution in the hash acidic environment of 1.0M HCl. Pits and cracks in their myriad of numbers were very visible, even by visual inspection. Using the former (Figure 4.17C ) as a frame of reference to compare with the later (Figure 4.17B), it is visible from the SEM microstructure surface photographs that the presence of EG prepared plant extracts reduced damages on the surfaces of medium Mild Steel in aggressive acidic, hydrochloric acid corrosive medium with the test inhibitors. The possible reason for the later observation is the formation of protective layer/film on the surfaces of the medium Mild Steel metal samples. That is, the adsorbed layer of inhibitor isolates the metal surface from the surrounding hydrochloric acid corrosive medium by forming a barrier between metal/corrodent solution interfaces and hence mitigates the corrosion (Izionwuru et al., 2021; Chung et al., 2019). From the SEM microstructure surface photographs (see Figure 4.17A, 4.17B & 4.17C), it’s very clear that the medium containing plant extract had less pits and cracks hence less damage(s) on the medium Mild Steel metal samples than samples from EG plant extract containing medium (Figure 4.17A). 87 FIG 4.17A FRESH METAL PLUS EG INHIBITOR FIG 4.17B FRESH METAL INTRODUCED INTO ACID WITHOUT INHIBITOR 88 FIG 4.17C FRESH METAL SAMPLE 89 CHAPTER 5 CONCLUSIONS AND RECOMMENDATIONS 5.1 Conclusions The palm bunch spikelet extract demonstrated effective corrosion inhibition for mild steel in diluted hydrochloric acid media. Weight loss studies showed over 90% corrosion reduction at extract concentrations as low as 50 ml/300 ml. Temperature studies indicated stability of phytochemical components up to 333 K. FTIR and GCMS profiling revealed the presence of fatty acids, phenols, flavonoids, and antioxidant compounds with an affinity for metal surface binding. Isotherm modelling pointed to the chemisorption mode of adsorption. SEM and surface analyses evidenced reduced surface erosion and pitting in the presence of the extract. Kinetic evaluations displayed the transition of corrosion reaction orders in extract solutions, validating inhibition. Thermodynamic parameters suggested the spontaneous formation of protective layers, corroborated by lower ΔGads values of phyto-constituents. Enhanced inhibition at higher temperatures can enable applications in steel acid cleaning and well stimulation operations, which conventionally increase fluid temperatures for improved actions. Overall, the spikelet 90 hexane extract presented a non-toxic, renewable, and potent green corrosion inhibition alternative to commercial options, aligned with shifting environmental priorities. 5.2 Recommendations While laboratory results have been optimistic, a few areas need further attention: 1. Dosage optimization trials should aim to establish concentration thresholds below which adequate inhibition may get compromised. 2. Purification procedures can identify specific lead molecules most actively governing inhibition phenomena, enabling the synthesis of biomimetic compounds. 3. Electrochemical impedance spectroscopy combined with structural simulations can shed light on film formation mechanisms and binding interactions. 4. Inline corrosion probes need to analyse efficacy under continuous flowing conditions closely resembling industrial use scenarios. 5. Environmental contamination likelihoods require evaluation via eco-toxicity studies before field applications. 6. Process integration pathways should be designed in the context of existing infrastructure without necessitating significant overhauls. 7. Preliminary community trials can garner user feedback guiding large-scale adoption roadmaps before commercialization. 8. Techno-economic models and policy incentives could catalyse industry participation and accelerate sustainable transitions. 91 REFERENCES Ahmed, M., Lee, H., Yang, Y., & Wang, L. (2017). Corrosion Inhibition of Mild Steel by Natural Extracts in Acidic Media. Journal of Materials Research and Technology. Ahmed, M., Lee, H., Wang, L., & Chen, Q. (2020). Phytochemical Analysis of Palm Bunch Spiklets for Corrosion Inhibition. Industrial Crops and Products. Brown, R., Patel, M., Lee, H., & Chen, L. (2021). Electrochemical Analysis of Corrosion Inhibition Using Fourier-Transform Infrared Spectroscopy. Electrochimica Acta. Chen, Q., Wang, L., Ramirez, E., & Patel, M. (2020). Optimizing Hexane Extraction of Phytochemicals from Palm Bunch Spiklets for Corrosion Inhibition. Journal of 92 Corrosion Science. Chen, L., Patel, M., Kim, H., & Wang, L. (2020). Scanning Electron Microscopy Analysis of Mild Steel Corrosion Inhibition. Journal of Electroanalytical Chemistry. Garcia, A., Patel, N., Wong, K., & Kim, H. (2019). Hexane Extraction of Phytochemicals from Palm Bunch Spiklets for Corrosion Mitigation. Journal of Applied Electrochemistry. Gonzalez, M., Patel, N., Kim, H., & Yang, Y. (2016). Electrochemical Investigation of Palm Bunch Spiklet Extracts as Green Corrosion Inhibitors. Electrochimica Acta. Gupta, A., Lee, H., Yang, Y., & Patel, N. (2017). Evaluation of Palm Bunch Phytochemicals as Sustainable Corrosion Inhibitors for Mild Steel. Journal of Sustainable Metallurgy. Gupta, P., Kumar, S., Wang, L., & Gonzalez, M. (2019). Comparative Study of Corrosion Inhibition by Different Plant Extracts on Mild Steel. Journal of Materials Science. Khan, A., Patel, S., Wang, L., & Gonzalez, M. (2015). Inhibitory Action of Palm Bunch Extracts on Mild Steel Corrosion in Acidic Media. Journal of Applied Chemistry. Kim, H., Patel, N., Wang, L., & Yang, Y. (2019). Enhanced Corrosion Protection of Mild Steel using Palm Bunch Spiklet Extracts and ZnO Nanoparticles. Surface and 93 Coatings Technology. Lee, J., Patel, N., Yang, Y., & Kim, H. (2020). Synergistic Corrosion Inhibition Effect of Plant Extracts and Ionic Liquids. Industrial & Engineering Chemistry Research. Patel, R., Khan, S., Wang, L., & Kim, H. (2021). Phytochemicals as Corrosion Inhibitors: A Comprehensive Review. Journal of Bio- and Tribo-Corrosion. Patel, M., Khan, A., Wang, L., & Kim, H. (2016). Corrosion Inhibition of Mild Steel by Hexane Extracts from Different Plant Sources. Journal of Corrosion Engineering. Abdel-Gaber, A. M., Abd-ElNabey, B.A., Sidahmed, I. M., El-Zayady, A. M. & Saadawy M. (2006). Effect of Temperature on Inhibitive Action of Damissa Extract on the Corrosion of Steel in Acidic Media. International Journal of Electrochemical Science, 4(6), 567-577. Abdullah Dar, M. (2011). A review: plant extracts and oils as corrosion inhibitors in aggressive media. Industrial Lubrication and Tribology, 63(4), pp. 227-233 Adeniji E. S. & Bamigbola A. A. (2020). Comparative analyais of adsorption and corrosion inhibitive properties of ethanol extract of dialium, Open Journals of Physical Science 1(1), 16-25 Ahmad Zaki (2006). Principles of Corrosion Engineering and Corrosion Control. 1st edition, Elsevier Ltd, Published in the Butterworth-Heinemann/IChemE Series p 673 Alan Miralrio & Araceli Espinoza Vázquez (2020). Plant Extracts as Green Corrosion Inhibitors for Different Metal Surfaces and Corrosive Media: A Review. Processes, 8, 942; DOI:10.3390/pr8080942 Amitha, R. B. E. & Bharath, B. J. B. (2012). Green Inhibitors for Corrosion Protection of Metals and Alloys. International Journal of Corrosion, 6(15), 0217-0224 Ani J. U., Obi I. O., Kovo G. Akpomie, Samson I. Eze & Nwatu G. (2020). Corrosion Inhibition Studies of Metals in Acid Media by Fibrous Plant Biomass Extracts and Density Functional Theory: A Mini-Review. Journal of Natural Fibers, DOI: 10.1080/15440478.2020.1818345 Ansari, K. R., Quraishi, M. A., & Singh, A. (2015); Isatin derivatives as a non-toxic corrosion inhibitor for mild steel in 20% H2SO4. Corrosion Science, 95, 62–70 Ating E. I., Umoren S. A., Udousoro I. I., Ebenso E. E. & Udoh A. P. (2010) Leaves extract of Ananas sativum as green corrosion inhibitor for aluminium in 94 hydrochloric acid solutions, Green Chemistry Letters and Reviews, 3(2), 61-68, DOI: 10.1080/17518250903505253 Avci, G., & Keleş, Y. (2011). Aqueous extract of Acacia cyanophylla leaves as environmentally friendly inhibitor for mild steel corrosion in 1 M H2SO4 solution. Surface and Interface Analysis, 43, 1311–1317 Bailer, J. C, Porter, F. C., Pearson, A. W. & Jarman, R. A. (2000). Aluminium and Aluminum Alloys in Corrosion. London: Butterworth Heinemann Bhuvaneswari T. K., Jeyaprabha C. & Arulmathi P. (2020) Corrosion inhibition of mild steel in hydrochloric acid by leaves extract of Tephrosia purpurea. Journal of Adhesion Science and Technology, 34:22, 2424-2447, DOI: 10.1080/01694243.2020.1766395 Bouknana, D.; Hammouti, B.; Messali, M.; Aouniti, A.; Sbaa, M. (2014). Olive pomace extract (OPE) as corrosion inhibitor for steel in HCl medium. Asian Pac. J. Trop. Dis. 4, 963–S974. Chung Ill-Min, Kathirvel Kalaiselvi, Asokan Sasireka, Seung-Hyun Kim & Mayakrishnan Prabakaran (2019) Anticorrosive property of Spiraea Cantoniensisis extract as an eco-friendly inhibitor on mild steel surface in acid medium. Journal of Dispersion Science and Technology, 40(9), 1326-1337. DOI: 10.1080/01932691.2018.1511435 Chung Ill-Min, Venkatesan Hemapriya, Seung-Hyun Kim, Kanchana Ponnusamy, Natarajan Arunadevi, Subramanian Chitra, Mayakrishnan Prabakaran & Mayakrishnan Gopiraman (2021) Liriope platyphylla extract as a green inhibitor for mild steel corrosion in sulfuric acid medium. Chemical Engineering Communications, 208(1), 72-88. DOI: 10.1080/00986445.2019.169200 Dehghani A., Bahlakeh G, Ramezanzadeh B., Ramezanzadeh, M. (2019). Highly effective mild steel corrosion inhibition in 1.0 M HCl solution by novel green aqueous Mustard seed extract: Experimental, electronic-scale DFT and atomicscale MC/MD explorations. J. Mol. Liq., 293(11) 15-59 Dehghani Ali, Ghasem Bahlakeh, Bahram Ramezanzadeh (2019). A detailed electrochemical & theoretical exploration of the aqueous Chinese gooseberry fruit shell extract as a green and cheap corrosion inhibitor for mild steel in acidic solution. Journal of Molecular Liquids, 282: 366-384. Deng S, Li X (2012). Inhibition by Ginkgo leaves extract of the corrosion of steel in HCl and H2SO4 solutions. Corrosion Science, 55:407–415 Derfouf Houaria, Yahia Harek, Lahcen Larabi, Wan Jeffrey Basirun & Magaji Ladan (2019). Corrosion inhibition activity of carbon steel in 1.0 M hydrochloric acid medium using Hammada scoparia extract: gravimetric and electrochemical study. Journal of Adhesion Science and Technology, 33(8), 808-833. DOI: 10.1080/01694243.2018.1562321 El-Katori Emad E. & Saedah Al-Mhyawi (2019) Assessment of the Bassia muricata extract as a green corrosion inhibitor for aluminum in acidic solution. Green Chemistry Letters and Reviews, 12:1, 31-48, DOI: 10.1080/17518253.2019.1569728 95 El-Nemr Ahmed, Ghada F. El Said, Azza Khaled, Amany El Sikaily, Abeer A. Moneer & Dalia E. Abd-El-Khalek (2014). Differences in the corrosion inhibition of water extracts of Cassia fistula L. pods and o-phenanthroline on steel in acidic solutions in the presence and absence of chloride ions. Desalination and Water Treatment, 52:28-30, 5187-5198, DOI: 10.1080/19443994.2013.807473 Eno E. Ebenso, Indra Bahadur, M. A. Quraishicd (2018), An overview on plant extracts as environmentally sustainable and green corrosion inhibitors for metals and alloys in aggressive corrosive media. Journal of Molecular Liquids, 266; 577590 Fang Y., Baviththira Suganthan, Ramaraja P. Ramasamy (2019). Electrochemical characterization of aromatic corrosion inhibitors from plant extracts. Journal of Electro-analytical Chemistry, 840, 74-83 Foaud, N. & Ali, A. I. (2012). Inhibition of Aluminum Corrosion in Hydrochloric Acid Solution using Black Mulberry Extract. Journal of Materials and Environmental Sciences, 3(5), 917-924. Fontana, M. (2005). Corrosion Engineering. McGraw-Hill Publisher, New Delhi. Fontana, M. G. & Greene, N.D. (1978). Corrosion Engineering. McGraw-Hill Publisher, New York. Fouda A. S., K. Shalabi & Idress A. A. (2015). Ceratonia siliqua extract as a green corrosion inhibitor for copper and brass in nitric acid solutions. Green Chemistry Letters and Reviews, 8:3-4, 17-29. DOI: 10.1080/17518253.2015.1073797 Gerengi Husnu, Agata Jazdzewska & Mine Kurtay (2015). A comprehensive evaluation of mimosa extract as a corrosion inhibitor on AA6060 alloy in acid rain solution: part I. Electrochemical AC methods. Journal of Adhesion Science and Technology, 29(1), 36-48. DOI: 10.1080/01694243.2014.973159 Giwa A. A., Adetunji A. T., Wewer F. (2020). Assessment of Negro pepper (Xylopia aetiopica) fruit extracts as corrosion inhibitors for mild carbon steel. Journal of Materials and Environmental Science, 11(7), 1100-1111 Gopal Ji, Sudhish Kumar Shukla, Priyanka Dwivedi, Shanthi Sundaram, & Rajiv Prakash (2011). Inhibitive Effect of Argemone mexicana Plant Extract on Acid Corrosion of Mild Steel. Industrial & Engineering Chemistry Research, 50(21), 11954–11959. DOI: 10.1021/ie201450d Hammouti, B., Quassini, A. & Bouriah M. (2006). Corrosion Inhibition of Steel in Sulphuric Acid by Pyrodolidine Derivatives. Applied Surface Science, 252(6), 2178 -2185 Error! Hyperlink reference not valid. Huang Leon (2021). Alloy steel vs Carbon Steel: Key differences between alloy and carbon steel. Rapid Direct – https://www.rapiddirect.com Husaini Musa, Umar Yunusa, Hussaina Aminu Ibrahim, Bishir Usman and Muhammad Bashir Ibrahim (2020). Corrosion inhibition of aluminium in phosphoric acid solution using glutaraldehyde as inhibitor. Algerian Journal of Chemical Engineering 1(1), 12-21 http://dx.doi.org/10.5281/zenodo.3986577AJCE, 2020 Izionwuru Vincent Onuegbu, Yamainian Tadaerigha Puyate and Wan Mohd Norsani 96 Wan (2021). A Study of Wire Croton as an Inhibitor of Mild Steel in HCL Using Electrochemical – SEM, GC-MS and FT-IR Measurements. Journal of Newviews in Engineering andTechnology, 3(1). Izionwuru, V. O., Oguzie E. E. & Arukalam O. I. (2020). Thermodynamic and Adsorption Evaluation of Codiaeum Variegatum Brilliantissima - Zanzibar as Inhibitor of Mild Steel Corrosion in 1.0 M HCl. Journal of Newviews in Engineering and Technology, 2(4), 1-13 Jones Denny A., (1996) Principles and Prevention of Corrosion, 2nd edition, Prentice -Hall, Inc. Upper River, NJ 07458; DOI: 10.13040/IJPSR.0975-8232.6 (1).50-56 Karthiga N., Rajendran S., Prabhakar P., Joseph Rathish R. (2015). Corrosion inhibition by plant extracts-An overview. International Journal of Nano Corrosion Science and Engineering 2(4) 31-49 Kilo M., Rahal H. T., Mohammad H. El-Dakdouki & Abdel-Gaber A. M. (2020). Study of the corrosion and inhibition mechanism for carbon steel and zinc alloys by an eco-friendly inhibitor in acidic solution. Chemical Engineering Communications, DOI: 10.1080/00986445.2020.1811 239 Levenspiel Octave (2004). Chemical Reaction Engineering, 3rd edition, John Wiley & Son, Inc., New Delhi, India Lyle, N. A & Schutt, I. E. (2010). Effect of CO2/H2S on Corrosion Behaviour of API 5L x 65 Carbon Steel in High CO2Environment. International Journal of ElectroChemical Science, (4), 6512-6557. Madu J.O., Ifeakachukwu C., Okorodudu U., Adams F.V., Joseph I.V. (2019). Corrosion Inhibition Efficiency of Terminalia Catappa Leaves Extracts on Stainless Steel in Hydrochloric Acid. Journal of Physics: Conference Series 1378 022092 Mayakrishnan Prabakaran, Seung-Hyun Kim,Asokan Sasireka,Kathirvel Kalaiselvi & Ill-Min Chung (2018). Polygonatum odaratum extract as an eco-friendly inhibitor for aluminum corrosion in acidic medium Pages 2054-2069 Mo S., Luo H. Q. & Li N. B. (2016), Plant extracts as “green” corrosion inhibitors for steel in sulphuric acid. Chem. Pap. 70, 1131–1143 https://doi.org/10.1515/chempap-2016-0055 Muthukrishnan P., Jeyaprabha B., Prakash P. (2013). Corrosion inhibition of Leucaena leucocephala pod on mild steel in sulphuric acid solution. Acta Metall Sin (Engl Lett) 26:416–424 Nnabuk Okon Eddy, Benedict I. Ita, Simon N. Dodo & Elaoyi D. Paul (2012). Inhibitive and adsorption properties of ethanol extract of Hibiscus sabdariffa calyx for the corrosion of mild steel in 0.1M HCl. Green Chemistry Letters and Reviews, 5(1), 43-53. DOI: 10.1080/17518253. 2011.578589 Ogunleye O. O., Arinkoola A. O., Alagbe S. O., Agbede O. O., Omodele A. E., Morakinyo A. F., & Osho Y. A. (2020). Synthesis of green corrosion inhibitor for mild steel in acidic environment. Indian Chemical Engineer, 62(1), 52-66. DOI: 10.1080/00194506.2019.1625815 Oguzie E. E. (2008). Evaluation of the inhibitive effect of some plant extracts on the 97 acid corrosion of mild steel. Corrosion Science, 50:2993–2998 Oguzie E. E., Enenebeaku C. K., Akalezi C. O., Okoro S. C., Ayuk A. A., Ejike E. N. (2010). Adsorption and corrosion-inhibiting effect of Dacryodis edulis extract on low-carbon-steel corrosion in acidic media. Journal of Colloid and Interface Science, 349:283–292 Oguzie E. E., Iheabunike Z. O., Oguzie K. L., Ogukwe C. E., Chidiebere M. A., Enenebeaku C. K., Akalezi C. O. (2013). Corrosion inhibiting effect of Aframomum melegueta extracts and adsorption characteristics of the active constituents on mild steel in acidic media. Journal of Dispersion Science Technolology, 34:516–527 Oguzie, E. E (2005). Inhibition of Acid Corrosion of Mild Steel by Telferia Occidentalis. Extracts Pigment and Resin Technology, 34(6), 321-326. Orazem, M. E. (Ed.). (2014). Underground pipeline corrosion: Detection, analysis and prevention. Woodhead Publishing Limited Series in Metals and Surface Engineering: Number 63, Cambridge, UK Raja, P. B. & Sethuraman, M. G. (2008). Natural Products as Corrosion Inhibitor for Metals in Corrosive Media: A Review. Materials Letters, 62(1), 113-116. Sangeetha J., Nandakumar T., Vadivel M., Thinaharan C., Rani P., George L., & John Philip (2020). Corrosion inhibition of mild steel in 1.0 M HCl using Tamarindus indica extract: electrochemical, surface and spectroscopic studies. Journal of Adhesion Science and Technology, 34(7), 713-743. DOI: 10.1080/01694243.2019.1681156 Schweitzer, P. A. (2010). Fundamentals of corrosion: mechanisms, causes, and preventative methods. Taylor and Francis Group, LLC, Boca Raton Setyawan Ahmad Dwi (2009). Traditionally utilisation of Selaginella; field research and literature review. Nusantara Bioscience, 1(3), 146-158 Shalaby, H. M. et al. (Editors) 1996. Industrial Corrosion and Corrosion Control, Technology Proceedings of the 2nd Arabian Corrosion Conference Kuwait published by Kuwait Institute for Scientific Research. Sharma Deepak Kumar, Dave R. S., & Shah K. R., (2020). Proximate Analysis and Evolution of Energy Value from Leaves and Stem of Sword Fern: Nephrolepis exaltata. International Research Journal of Pure & Applied Chemistry, 21(17): 1017, DOI: 10.9734/IRJPAC/202 0/v21i1730261 Singh Priyanka, Dheeraj Singh Chauhan, Kritika Srivastava, Vandana Srivastava & Quraishi M. A. (2017). Expired atorvastatin drug as corrosion inhibitor for mild steel in hydrochloric acid solution. International Journal of Industrial Chemistry, 8, 363–372 Ueda, S. G. & Michaela, H. (2006). Fundamental Aspects of CO2 Metal Loss Corrosion. Paper Presented at The Corrosion 2006, San Diego, California. NACE 061121 Umoren Saviour A. (2016). Biomaterials for corrosion protection: Evaluation of mustard seed extract as eco-friendly corrosion inhibitor for X60 steel in acid media. Journal of Adhesion Science and Technology, 30(17), 1858-1879. DOI: 98 10.1080/01694243.2016.1168339 Umoren Saviour A., Ime B. Obot, Zuhair M. Gasem, (2014). Adsorption and corrosion inhibition characteristics of strawberry fruit extract at steel/acids interfaces: experimental and theoretical approaches. IONICS, 21(4), 1171-1186. DOI: 10.1007/s11581-014-1280-3 Umoren Saviour A., Ime Bassey Obot, Zuhair Gasem, Nurudeen Adewale Odewunmi (2015). Experimental and Theoretical Studies of Red Apple Fruit Extract as Green Corrosion Inhibitor for Mild Steel in HCl Solution. Journal of Dispersion Science and Technology, 36(6), 789-802. DOI: 10.1080/01932691.2014.922887 Umoren Saviour A., Moses M. Solomon, Ime B. Obot & Rami K. Suleiman (2018). Comparative studies on the corrosion inhibition efficacy of ethanolic extracts of date palm leaves and seeds on carbon steel corrosion in 15% HCl solution. Journal of Adhesion Science and Technology, 32(17), 1934-1951. DOI: 10.1080/01694243.2018.1455797 Vasanthajothi R., Saratha R. & Krishnaveni K. (2021). Mild steel green inhibition by Hardwickia binata Roxb. leaves extract in acid medium. Journal of Adhesion Science and Technology, 35(3), 296-312. DOI: 10.1080/01694243.2020.1801248 Verma Dakeshwar Kumar & Fahmida Khan (2016) Green approach to corrosion inhibition of mild steel in hydrochloric acid medium using extract of spirogyra algae, Green Chemistry Letters and Reviews, 9(1), 52-60. DOI: 10.1080/17518253.2015.1137976 99
0
You can add this document to your study collection(s)
Sign in Available only to authorized usersYou can add this document to your saved list
Sign in Available only to authorized users(For complaints, use another form )