1
ASSIGNMENT # 2 -- AS
(MEASUREMENTS & UNCERTAINTIES)
MCQ
NAME:________________________
CLASS: _______________
2
1
In an experiment, a radio-controlled car takes 2.50 ± 0.05 s to travel 40.0 ± 0.1 m.
What is the car’s average speed and the uncertainty in this value?
2
A
16 ± 1 m s–1
B
16.0 ± 0.2 m s–1
C
16.0 ± 0.4 m s–1
D
16.00 ± 0.36 m s–1
The diagram shows two pulses on the screen of a cathode ray oscilloscope. A grid of 1 cm
squares covers the screen. The time base setting is 1 µs cm–1.
1 cm
How long does each pulse last?
A
3
B
2 µs
C
3 µs
4 µs
D
6 µs
A steel rule can be read to the nearest millimetre. It is used to measure the length of a bar whose
true length is 895 mm. Repeated measurements give the following readings.
length / mm
892, 891, 892, 891, 891, 892
Are the readings accurate and precise to within 1 mm?
results are accurate
to within 1 mm
results are precise
to within 1 mm
A
no
no
B
no
yes
C
yes
no
D
yes
yes
3
4
The density of the material of a rectangular block is determined by measuring the mass and
linear dimensions of the block. The table shows the results obtained, together with their
uncertainties.
mass
=
(25.0 ± 0.1) g
length
=
(5.00 ± 0.01) cm
breadth
=
(2.00 ± 0.01) cm
height
=
(1.00 ± 0.01) cm
The density is calculated to be 2.50 g cm–3.
What is the uncertainty in this result?
A
5
± 0.01 g cm–3
B
± 0.02 g cm–3
C
± 0.05 g cm–3
D
± 0.13 g cm–3
The cathode-ray oscilloscope (c.r.o.) display shows the waveform produced by an electronic
circuit. The c.r.o. time-base is set at 10 ms per division.
What is the period of the signal shown?
A
20 ms
B
30 ms
C
40 ms
D
80 ms
6 The resistance R of an unknown resistor is found by measuring the potential difference V across
the resistor and the current I through it and using the equation R =
V
. The voltmeter reading has
I
a 3 % uncertainty and the ammeter reading has a 2 % uncertainty.
What is the uncertainty in the calculated resistance?
A
1.5 %
B
3%
C
5%
D
6%
[Turn over
4
7
The Y-input terminals of a cathode-ray oscilloscope (c.r.o.) are connected to a supply of peak
value 5.0 V and of frequency 50 Hz. The time-base is set at 10 ms per division and the Y-gain at
5.0 V per division.
Which trace is obtained?
8
A
B
C
D
The measurement of a physical quantity may be subject to random errors and to systematic
errors.
Which statement is correct?
9
A
Random errors can be reduced by taking the average of several measurements.
B
Random errors are always caused by the person taking the measurement.
C
A systematic error cannot be reduced.
D
A systematic error results in a different reading each time the measurement is taken.
An experiment is done to measure the resistance of a wire.
The current in the wire is 1.0 ± 0.2 A and the potential difference across the wire is 8.0 ± 0.4 V.
What is the resistance of the wire and its uncertainty?
A
(8.0 ± 0.2) Ω
B
(8.0 ± 0.6) Ω
C
(8 ± 1) Ω
D
(8 ± 2) Ω
5
10
An oscilloscope display consists of two separate traces, a waveform and a long horizontal line.
The horizontal line may be taken as the zero level.
The grid on the screen is calibrated in cm squares, the timebase setting is 2.5 ms cm–1, and the
Y-sensitivity is 5 mV cm–1.
What are the period and the peak positive voltage of the waveform in the diagram?
peak positive voltage / mV
A
5
17
B
5
25
C
10
17
D
10
25
The resistance of an electrical component is measured. The following meter readings are
obtained.
0.6
0.4
0.2
0.8
mV
1.0
A
0
11
period / ms
What is the resistance?
A
2.5 Ω
B
2.7 Ω
C
2500 Ω
D
2700 Ω
[Turn over
6
12
A series of measurements of the acceleration of free fall g is shown in the table.
Which set of results is precise but not accurate?
g / m s–2
13
A
9.81
9.79
9.84
9.83
9.79
B
9.81
10.12
9.89
8.94
9.42
C
9.45
9.21
8.99
8.76
8.51
D
8.45
8.46
8.50
8.41
8.47
A mass m has acceleration a. It moves through a distance s in time t. The power used in
accelerating the mass is equal to the product of force and velocity. The percentage uncertainties
are
0.1 % in m,
1 % in a,
1.5 % in s,
0.5 % in t.
What is the percentage uncertainty in the average power?
A
2.1 %
B
2.6 %
C
3.1 %
D
4.1 %
7
14 The diagram shows the graduations of a correctly calibrated ammeter. When the current is zero,
the pointer is at 0.
0
1
2
3 45
The ammeter is accidentally readjusted so that when the current is zero, the pointer is at X.
X
0
1
2
3 45
Which calibration graph best represents the response of the readjusted ammeter?
A
B
angle of
deflection of
pointer from
the zero mark
angle of
deflection of
pointer from
the zero mark
0
0
0
current
0
C
current
D
angle of
deflection of
pointer from
the zero mark
angle of
deflection of
pointer from
the zero mark
0
0
0
current
0
current
[Turn over
8
15
What is a reasonable estimate of the average kinetic energy of an athlete during a 100 m race
that takes 10 s?
A
16
40 J
B
C
400 J
D
4000 J
40 000 J
The resistance R of a resistor is determined by measuring the potential difference V across it and
the current I in it. The value of R is then calculated using the equation
R= V .
I
The values measured are V = 1.00 ± 0.05 V and I = 0.50 ± 0.01 A.
What is the percentage uncertainty in the value of R ?
A
17
2.5 %
B
C
3.0 %
D
7.0 %
10.0 %
A student uses a digital ammeter to measure a current. The reading of the ammeter is found to
fluctuate between 1.98 A and 2.02 A.
The manufacturer of the ammeter states that any reading has a systematic uncertainty of ± 1 %.
Which value of current should be quoted by the student?
18
A
(2.00 ± 0.01) A
B
(2.00 ± 0.02) A
C
(2.00 ± 0.03) A
D
(2.00 ± 0.04) A
A calibration graph is produced for a faulty ammeter.
1.0
ammeter
reading / A
0
0
1.0
true
current / A
Which ammeter reading will be nearest to the correct value?
A
0.2 A
B
0.4 A
C
0.6 A
D
0.8 A
9
19
The diagram shows the stem of a Celsius thermometer marked to show initial and final
temperature values.
initial
temperature
–10
final
temperature
–5
0
+5
+10
+15
What is the temperature change expressed to an appropriate number of significant figures?
A
20
14 °C
B
20.5 °C
C
21 °C
D
22.0 °C
The diagrams show digital voltmeter and analogue ammeter readings from a circuit in which
electrical heating is occurring.
0.6
0.4
0.2
0.8
mV
0
1.0
A
What is the electrical power of the heater?
A
21
B
0.53 W
C
0.58 W
D
530 W
580 W
The graph shows two current-voltage calibration curves for a solar cell exposed to different light
intensities.
intensity = 1000 W m–2
3.0
current / A
2.0
1.0
intensity = 100 W m–2
0
0
0.1
0.2
0.3
0.4
0.5
0.6
voltage / V
_
At zero voltage, what is the ratio
A
1.1
B
4.7
current at 1000 W m 2
_
current at 100 W m 2
C
8.0
?
D
10
[Turn over
10
22
The diagram shows an oscilloscope screen displaying two signals.
X
Y
Signal X has a frequency of 50 Hz and peak voltage of 12 V.
What is the period and peak voltage of signal Y?
23
period / ms
peak voltage
/V
A
20
4
B
20
12
C
50
4
D
50
12
The diagram shows a square-wave trace on the screen of a cathode-ray oscilloscope. A grid of
1 cm squares covers the screen. The time-base setting is 10 ms cm–1.
1 cm
1 cm
What is the approximate frequency of the square wave?
A
70 Hz
B
140 Hz
C
280 Hz
D
1400 Hz
11
24
A student finds the density of a liquid by measuring its mass and its volume. The following is a
summary of his measurements.
mass of empty beaker = (20 ± 1) g
mass of beaker + liquid = (70 ± 1) g
= (10.0 ± 0.6) cm3
volume of liquid
He correctly calculates the density of the liquid as 5.0 g cm–3.
What is the uncertainty in this value?
A
25
0.3 g cm–3
B
0.5 g cm–3
C
0.6 g cm–3
D
2.6 g cm–3
A micrometer screw gauge is used to measure the diameter of a copper wire.
The reading with the wire in position is shown in diagram 1. The wire is removed and the jaws of
the micrometer are closed. The new reading is shown in diagram 2.
0
15
20
10
15
0
5
diagram 1
10
diagram 2
What is the diameter of the wire?
A
1.90 mm
B
2.45 mm
C
2.59 mm
D
2.73 mm
[Turn over
12
26
The angular deflection of the needle of an ammeter varies with the current passing through the
ammeter as shown in the graph.
angular
deflection
0
0
current
Which diagram could represent the appearance of the scale on this meter?
A
0
1
2
3
4
B
5 6
7 8
9
2
01
3 4
5
C
0
27
6
7
8
9
D
3 456 7
1 2
8
2
01
9
3
5
4
6
7 8
9
The diagram shows a cathode-ray oscilloscope (c.r.o.) being used to measure the rate of rotation
of a flywheel.
flywheel
10 cm
M
coil
The flywheel has a small magnet M mounted on it. Each time the magnet passes the coil, a
voltage pulse is generated, which is passed to the c.r.o. The display of the c.r.o. is 10 cm wide.
The flywheel is rotating at a rate of about 3000 revolutions per minute.
Which time-base setting will display clearly separate pulses on the screen?
A
1 s cm–1
B
10 ms cm–1
C
100 µs cm–1
D
1 µs cm–1
13
28
A fixed quantity x0 is measured many times in an experiment that has experimental uncertainty. A
graph is plotted to show the number n of times that a particular value x is obtained.
Which graph could be obtained if the measurement of x0 has a large systematic error but a small
random error?
B
A
n
n
0
0
x0
x
x0
D
C
n
n
0
0
x0
29
x
x0
x
A metre rule is used to measure the length of a piece of wire. It is found to be 70 cm long to the
nearest millimetre.
How should this result be recorded in a table of results?
A
30
x
0.7 m
B
0.70 m
C
0.700 m
D
0.7000 m
A quantity x is to be determined from the equation
x = P – Q.
P is measured as 1.27 ± 0.02 m.
Q is measured as 0.83 ± 0.01 m.
What is the percentage uncertainty in x to one significant figure?
A
0.4 %
B
2%
C
3%
D
7%
14
31
The Young modulus of the material of a wire is to be found. The Young modulus E is given by the
equation below.
E=
4Fl
πd 2 x
The wire is extended by a known force and the following measurements are made.
Which measurement has the largest effect on the uncertainty in the value of the calculated
Young modulus?
32
measurement
symbol
value
A
length of wire before force applied
l
2.043 ± 0.002 m
B
diameter of wire
d
0.54 ± 0.02 mm
C
force applied
F
19.62 ± 0.01 N
D
extension of wire with force applied
x
5.2 ± 0.2 mm
The uncertainty in the value of the momentum of a trolley passing between two points X and Y
varies with the choice of measuring devices.
Measurements for the same trolley made by different instruments were recorded.
1
distance between X and Y using a metre rule with cm divisions = 0.55 m
2
distance between X and Y using a metre rule with mm divisions = 0.547 m
3
timings using a wristwatch measuring to the nearest 0.5 s at X = 0.0 s and at Y = 4.5 s
4
timings using light gates measuring to the nearest 0.1 s at X = 0.0 s and at Y = 4.3 s
5
mass of trolley using a balance measuring to the nearest g = 6.4 × 10–2 kg
6
mass of trolley using a balance measuring to the nearest 10 g = 6 × 10–2 kg
Which measurements, one for each quantity measured, lead to the least uncertainty in the value
of the momentum of the trolley?
A
1, 3 and 6
B
1, 4 and 6
C
2, 3 and 6
D
2, 4 and 5
15
33
The time-base on a cathode-ray oscilloscope is set at 6 ms / cm.
A trace consisting of two pulses is recorded as shown in the diagram.
2.5 cm
4.5 cm
34
The diagram shows an experiment to measure the speed of a small ball falling at constant speed
through a clear liquid in a glass tube.
What is the time interval between the two pulses?
A
0.42 ms
B
0.75 ms
C
1.33 ms
D
1.50 s
115 mm
3.50 s
385 mm
27 ms
There are two marks on the tube. The top mark is positioned at 115 ± 1 mm on the adjacent rule
and the lower mark at 385 ± 1 mm. The ball passes the top mark at 1.50 ± 0.02 s and passes the
lower mark at 3.50 ± 0.02 s.
−
The constant speed of the ball is calculated by 385 115 = 270 = 135 mm s–1.
2.00
3.50 − 1.50
Which expression calculates the fractional uncertainty in the value of this speed?
A
2 + 0.04
270
2.00
B
2 – 0.04
270
2.00
C
1 × 0.02
270
2.00
D
1 ÷ 0.02
270
2.00
16
35
The diagram shows a trace of a wave on a cathode-ray oscilloscope
The vertical and horizontal gridlines have a spacing of 1.0 cm. The voltage scaling is 4 V cm–1 and
the time scaling is 5 ms cm–1.
1 cm
1 cm
What are the amplitude and period of the wave?
36
amplitude / V
period / ms
A
1.5
4
B
5.0
10
C
6.0
20
D
12.0
20
A micrometer is used to measure the diameters of two cylinders.
diameter of first cylinder = 12.78 ± 0.02 mm
diameter of second cylinder = 16.24 ± 0.03 mm
The difference in the diameters is calculated.
What is the uncertainty in this difference?
A
37
± 0.01 mm
B
± 0.02 mm
C
± 0.03 mm
D
± 0.05 mm
The speedometer in a car consists of a pointer which rotates. The pointer is situated several
millimetres from a calibrated scale.
What could cause a random error in the driver’s measurement of the car’s speed?
A
The car’s speed is affected by the wind direction.
B
The driver’s eye is not always in the same position in relation to the pointer.
C
The speedometer does not read zero when the car is at rest.
D
The speedometer reads 10 % higher than the car’s actual speed.
[Turn over
17
38
The Young modulus of the material of a wire is to be found. The Young modulus E is given by the
equation below.
E=
4Fl
πd 2 x
The wire is extended by a known force and the following measurements are made.
Which measurement has the largest effect on the uncertainty in the value of the calculated
Young modulus?
39
measurement
symbol
value
A
length of wire before force applied
l
2.043 ± 0.002 m
B
diameter of wire
d
0.54 ± 0.02 mm
C
force applied
F
19.62 ± 0.01 N
D
extension of wire with force applied
x
5.2 ± 0.2 mm
The diameter of a cylindrical metal rod is measured using a micrometer screw gauge.
The diagram below shows an enlargement of the scale on the micrometer screw gauge when
taking the measurement.
40
2
3
30
0.5 mm / rev
What is the cross-sectional area of the rod?
A
40
3.81 mm2
B
11.4 mm2
C
22.8 mm2
D
45.6 mm2
A mass is dropped from rest, and falls through a distance of 2.0 m in a vacuum. An observer
records the time taken for the mass to fall through this distance using a manually operated
stopwatch and repeats the measurements a further two times. The average result of these
measured times, displayed in the table below, was used to determine a value for the acceleration
of free fall. This was calculated to be 9.8 m s–2.
time / s
first measurement
second measurement
third measurement
average
0.6
0.73
0.59
0.64
Which statement best relates to the experiment?
A
The measurements are precise and accurate with no evidence of random errors.
B
The measurements are not accurate and not always recorded to the degree of precision of
the measuring device but the calculated experimental result is accurate.
C
The measurements are not always recorded to the degree of precision of the measuring
device but are accurate. Systematic errors may be present.
D
The range of results shows that there were random errors made but the calculated value is
correct so the experiment was successful.
[Turn over
18
41
The diagram shows two complete pulses on the screen of a cathode-ray oscilloscope. A grid of
1 cm squares covers the screen. The time-base setting is 1 µs cm–1.
1 cm
How long does each pulse last?
A
42
2 µs
B
3 µs
C
4 µs
D
6 µs
In an experiment, a radio-controlled car takes 2.50 ± 0.05 s to travel 40.0 ± 0.1 m.
What is the car’s average speed and the uncertainty in this value?
A
16 ± 1 m s–1
B
16.0 ± 0.2 m s–1
C
16.0 ± 0.4 m s–1
D
16.00 ± 0.36 m s–1
43 The density of the material of a coil of thin wire is to be found.
Which set of instruments could be used to do this most accurately?
A
metre rule, protractor, spring balance
B
micrometer, metre rule, top-pan balance
C
stopwatch, newton-meter, vernier calipers
D
tape measure, vernier calipers, lever balance
[Turn over
19
44 A quantity X vari es w ith temperature θas shown.
X
0
0
100 °C
θ
θ is determined from the corresponding values of X by using this graph.
X is measured with a percentage uncertainty of ±1 % of its value at all temperatures.
Which statement about the uncertainty in θ is correct?
A
The percentage uncertainty in θ is least near 0 °C.
B
The percentage uncertainty in θ is least near 100 °C.
C
The actual uncertainty in θ is least near 0 °C.
D
The actual uncertainty in θ is least near 100 °C.
45 The measurement of a physical quantity may be subject to random errors and to systematic
errors.
Which statement is correct?
A
Random errors can be reduced by taking the average of several measurements.
B
Random errors are always caused by the person taking the measurement.
C
A systematic error cannot be reduced by adjusting the apparatus.
D
A systematic error results in a different reading each time the measurement is taken.
20
46 The diagram shows a graph of displacement against time for a sound wave.
displacement
0
0
time
The intensity of the sound is halved.
Which graph shows the displacement of this sound wave?
A
B
displacement
0
displacement
0
time
0
0
C
D
displacement
0
time
displacement
0
time
0
0
time
47 A student is given a reel of wire of diameter less than 0.2 mm and is asked to find the density of
the metal.
Which pair of instruments would be most suitable for finding the volume of the wire?
A
balance and micrometer
B
metre rule and micrometer
C
metre rule and vernier calipers
D
micrometer and vernier calipers
21
48 Variables x and y are related by the equation y = p – qx where p and q are constants.
Values of x and y are measured experimentally. The results contain a systematic error.
Which graph best represents these results?
A
B
y
y
p
p
0
0
0
x
0
x
C
D
y
y
p
p
0
0
0
x
0
x
49 The speed of a car is calculated from measurements of the distance travelled and the time taken.
The distance is measured as 200 m, with an uncertainty of ± 2 m.
The time is measured as 10.0 s, with an uncertainty of ± 0.2 s.
What is the percentage uncertainty in the calculated speed?
A
± 0.5 %
B
±1%
C
±2%
D
±3%
22
50 A cathode-ray oscilloscope displays a square wave, as shown in the diagram.
The time-base setting is 0.20 ms per division.
What is the frequency of the square wave?
A
8.3 Hz
B
830 Hz
C
1300 Hz
D
1700 Hz
51 What will reduce the systematic errors when taking a measurement?
A
adjusting the needle on a voltmeter so that it reads zero when there is no potential difference
across it
B
measuring the diameter of a wire at different points and taking the average
C
reducing the parallax effects by using a marker and a mirror when measuring the amplitude
of oscillation of a pendulum
D
timing 20 oscillations, rather than a single oscillation, when finding the period of a pendulum
52 In an experiment to determine the acceleration of free fall g, the time t taken for a ball to fall
through distance s was measured. The uncertainty in the measurement of s is estimated to
be 2 %. The uncertainty in the measurement of t is estimated to be 3 %.
The value of g is determined using the equation
g = 2s2 .
t
What is the uncertainty in the calculated value of g?
A
53
1%
B
5%
C
8%
D
11 %
In an experiment to determine the acceleration of free fall g, the period of oscillation T and leng
l of a simple pendulum were measured. The uncertainty in the measurement of l is estimated to
be 4%, and the uncertainty in the measurement of T is estimated to be 1%.
The value of g is determined using the formula
g=
4π 2l
.
T2
What is the uncertainty in the calculated value for g ?
A
2%
B
3%
C
5%
D
6%
[Turn over
23
54
The Y-input terminals of a cathode-ray oscilloscope (c.r.o.) are connected to a supply of
amplitude 5.0 V and frequency 50 Hz. The time-base is set at 10 ms per division and the Y-gain at
5.0 V per division.
Which trace is obtained?
55
A
B
C
D
A student carried out an experiment in which an electric current was known to decrease with
time. The readings he found, from first to last, were 3.62 mA, 2.81 mA, 1.13 mA, 1.76 mA and
0.90 mA.
Which statement could not explain the anomalous 1.13 mA reading?
A
He has reversed the third and fourth readings in the results table.
B
He read the ammeter incorrectly; the reading should have been 2.13 mA.
C
He took the current reading at the wrong time.
D
There was a systematic error in the readings from the ammeter.
24
56
The diagram shows a calibration curve for a thermistor, drawn with an unusual scale on the
vertical axis.
100 000
resistance / Ω
10 000
1000
100
0
10
20
30
40
50
temperature / °C
What is the thermistor resistance corresponding to a temperature of 40 °C?
A
57
130 Ω
B
150 Ω
C
400 Ω
D
940 Ω
A student takes measurements of the current in a resistor of constant resistance and the potential
difference (p.d.) across it. The readings are then used to plot a graph of current against p.d.
There is a systematic error in the current readings.
How could this be identified from the graph?
58
A
At least one anomalous data point can be identified.
B
The data points are scattered about the straight line of best fit.
C
The graph is a curve, not a straight line.
D
The straight line graph does not pass through the origin.
A signal that repeats periodically is displayed on the screen of a cathode-ray oscilloscope.
The screen has 1 cm squares and the time base is set at 2.00 ms cm–1.
What is the frequency of this periodic signal?
A
50 Hz
B
100 Hz
C
125 Hz
D
200 Hz
25
59
A micrometer screw gauge is used to measure the diameter of a small uniform steel sphere. The
micrometer reading is 5.00 mm ± 0.01 mm.
What will be the percentage uncertainty in a calculation of the volume of the sphere, using these
values?
A
60
0.2%
B
C
0.4%
D
0.6%
1.2%
An uncalibrated analogue voltmeter P is connected in parallel with another voltmeter Q which is
known to be accurately calibrated. For a range of values of potential difference (p.d.), readings
are taken from the two meters.
The diagram shows the calibration graph obtained.
8
uncalibrated meter P
scale reading
6
4
2
0
0
1
2
3
4
5
6
calibrated meter Q
p.d. / V
The graph shows that meter P has a zero error. This meter is now adjusted to remove this zero
error. When the meter is recalibrated, the gradient of the calibration graph is found to be
unchanged.
What is the new scale reading on meter P when it is used to measure a p.d. of 5.0 V?
A
6.6
B
6.7
C
7.2
D
7.4
61 A student wishes to determine the densityρ of lead. She measures the mass and diameter of a
small sphere of lead:
mass = (0.506 ± 0.005) g
diameter = (2.20 ± 0.02) mm.
What is the best estimate of the percentage uncertainty in her value of ρ ?
A
1.9%
B
2.0%
C
2.8%
D
3.7%
26
62
An experiment is carried out to measure the resistance of a wire.
The current in the wire is (1.0 ± 0.2) A and the potential difference across the wire is (8.0 ± 0.4) V.
What is the resistance of the wire and its uncertainty?
63
A
(8.0 ± 0.2) Ω
B
(8.0 ± 0.6) Ω
C
(8 ± 1) Ω
D
(8 ± 2) Ω
A cathode-ray oscilloscope (c.r.o.) is connected to an alternating voltage. The following trace is
produced on the screen.
1 cm
1 cm
The oscilloscope time-base setting is 0.5 ms cm–1 and the Y-plate sensitivity is 2 V cm–1.
Which statement about the alternating voltage is correct?
A
The amplitude is 3.5 cm.
B
The frequency is 0.5 kHz.
C
The period is 1 ms.
D
The wavelength is 4 cm.
27
64
A quantity y is to be determined from the equation shown.
y=
px
q2
The percentage uncertainties in p, x and q are shown.
percentage
uncertainty
p
6%
x
2%
q
4%
What is the percentage uncertainty in y?
A
65
0.5 %
B
1%
C
16 %
D
192 %
A thermometer can be read to an accuracy of ± 0.5 °C. This thermometer is used to measure a
temperature rise from 40 °C to 100 °C.
What is the percentage uncertainty in the measurement of the temperature rise?
A
66
0.5 %
B
0.8 %
C
1.3 %
D
1.7 %
The resistance of a lamp is calculated from the value of the potential difference (p.d.) across it
and the value of the current passing through it.
Which statement correctly describes how to combine the uncertainties in the p.d. and in the
current?
67
A
Add together the actual uncertainty in the p.d. and the actual uncertainty in the current.
B
Add together the percentage uncertainty in the p.d. and the percentage uncertainty in the
current.
C
Subtract the actual uncertainty in the current from the actual uncertainty in the p.d.
D
Subtract the percentage uncertainty in the current from the percentage uncertainty in the p.d.
The display on a cathode-ray oscilloscope shows the signal produced by an electronic circuit.
The time-base is set at 5.0 ns per division and the Y-gain at 10 V per division.
What is the frequency of the signal?
A
2.0 × 10–8 Hz
B
2.5 × 10–2 Hz
C
5.0 × 107 Hz
D
3.1 × 108 Hz
28
68
A digital caliper is used to measure the 28.50 mm width of a plastic ruler. The digital caliper reads
to the nearest 0.01 mm.
What is the correct way to record this reading?
A
0.02850 ± 0.01 m
B
0.0285 ± 0.001 m
C
(2.850 ± 0.001) × 10–2 m
D
(2.850 ± 0.001) × 10–3 m
69 A cathode-ray oscilloscope (c.r.o.) displays a waveform corresponding to a sound wave.
In order to determine the frequency of the sound wave, which part of the displayed waveform
must be measured and which c.r.o. setting must be known?
70
on-screen
measurement
c.r.o. setting
A
amplitude
time-base
B
amplitude
Y-gain
C
wavelength
time-base
D
wavelength
Y-gain
A 0.10 kg mass is taken to Mars and then weighed on a spring balance and on a lever balance.
The acceleration due to gravity on Mars is 38% of its value on Earth.
What are the readings on the two balances on Mars? (Assume that on Earth g = 10 m s–2.)
71
spring
balance / N
lever
balance / kg
A
0.38
0.038
B
0.38
0.10
C
1.0
0.038
D
1.0
0.10
A steel wire is stretched in an experiment to determine the Young modulus for steel.
The uncertainties in the measurements are given below.
measurement
uncertainty
load on wire
±2%
length of wire
±0.2%
diameter of wire
±1.5%
extension
±1%
What is the percentage uncertainty in the Young modulus?
A
1.3%
B
1.8%
C
4.7%
D
6.2%
29
72
In the circuit shown, an analogue ammeter is to be recalibrated as a thermometer. The graph
shows how the resistance R of the thermistor changes with temperature T.
R/Ω
A
0
100
T / °C
Which diagram could represent the temperature scale on the ammeter?
A
20
0
B
40 6
0 80
100
0 20
40 60
°C
73
C
80
100
80
60
100
°C
D
40
20
0
100
80 60
°C
The diagram shows part of a thermometer.
40
20
0
°C
°C
25
20
What is the correct reading on the thermometer and the uncertainty in this reading?
uncertainty
in reading / °C
reading / °C
74
A
24
±1
B
24
±0.5
C
24
±0.2
D
24.0
±0.5
The resistance R of a resistor is to be determined. The current I in the resistor and the potential
difference V across it are measured.
The results, with their uncertainties, are
V = (15.0 ± 0.5) V.
I = (2.0 ± 0.2) A
The value of R is calculated to be 7.5 Ω.
What is the uncertainty in this value for R ?
A
± 0.3 Ω
B
± 0.5 Ω
C
± 0.7 Ω
D
±1Ω
30
75
A whale produces sound waves of frequency 5 Hz. The waves are detected by a microphone and
displayed on an oscilloscope.
What is the time-base setting on the oscilloscope?
A
76
0.1 ms div–1
1 ms div–1
B
C
10 ms div–1
D
100 ms div–1
The angular deflection of the needle of an ammeter varies with the current in the ammeter as
shown in the graph.
angular
deflection
0
0
current
Which diagram could represent the appearance of the scale on this meter?
A
0
1
2
3
4
B
5 6
7 8
9
2
01
3 4
C
0
77
3 456 7
1 2
5
6
7
8
9
D
8
01
9
2 3
4
5
6
7 8
9
The strain energy W of a spring is determined from its spring constant k and extension x. The
spring obeys Hooke’s law and the value of W is calculated using the equation shown.
W = 21 kx 2
The spring constant is 100 ± 2 N m–1 and the extension is 0.050 ± 0.002 m.
What is the percentage uncertainty in the calculated value of W ?
A
6%
B
10%
C
16%
D
32%
31
78
An analogue ammeter has a pointer which moves over a scale. Following prolonged use, the
pointer does not return fully to zero when the current is turned off and the meter has become less
sensitive at higher currents than it is at lower currents.
Which diagram best represents the calibration graph needed to obtain an accurate current
reading?
A
B
scale
reading
scale
reading
0
0
0
true current
0
true current
C
D
scale
reading
scale
reading
0
79
0
0
true current
0
true current
A single sheet of aluminium foil is folded twice to produce a stack of four sheets. The total
thickness of the stack of sheets is measured to be (0.80 ± 0.02) mm. This measurement is made
using a digital caliper with a zero error of (−0.20 ± 0.02) mm.
What is the percentage uncertainty in the calculated thickness of a single sheet?
A
80
1.0%
B
2.0%
C
4.0%
D
6.7%
In an experiment to determine the acceleration of free fall g, a ball bearing is held by an
electromagnet. When the current to the electromagnet is switched off, a clock starts and the ball
bearing falls. After falling a distance h, the ball bearing strikes a switch to stop the clock which
measures the time t of the fall.
If systematic errors cause t and h to be measured incorrectly, which error must cause g to
appear greater than 9.81 m s–2?
A
h measured as being smaller than it actually is and t is measured correctly
B
h measured as being smaller than it actually is and t measured as being larger than it
actually is
C
h measured as being larger than it actually is and t measured as being larger than it actually
is
D
h is measured correctly and t measured as being smaller than it actually is
32
81
A student is given a reel of wire of diameter less than 0.2 mm and is asked to find the density of
the metal.
Which pair of instruments would be most suitable for finding the volume of the wire?
82
A
balance and micrometer
B
metre rule and micrometer
C
metre rule and vernier calipers
D
micrometer and vernier calipers
Four different students use a ruler to measure the length of a 15.0 cm pencil. Their
measurements are recorded on four different charts.
Which chart shows measurements that are precise but not accurate?
83
B
C
D
15.4
15.4
15.2
15.2
15.2
15.2
15.0
15.0
15.0
15.0
14.8
14.6
14.4
14.8
14.6
14.4
length / cm
15.4
length / cm
15.4
length / cm
length / cm
A
14.8
14.6
14.4
14.8
14.6
14.4
14.2
14.2
14.2
14.2
14.0
14.0
14.0
14.0
13.8
13.8
13.8
13.8
In a simple electrical circuit, the current in a resistor is measured as (2.50 ± 0.05) mA. The
resistor is marked as having a value of 4.7 Ω ± 2 %.
If these values were used to calculate the power dissipated in the resistor, what would be the
percentage uncertainty in the value obtained?
A
2%
B
4%
C
6%
D
8%
33
84
A calibration graph is shown for an ammeter whose scale is inaccurate.
0.6
ammeter
reading
/ mA
0.5
0.4
0.3
0.2
0.1
0
0
0.1
0.2
0.3
0.4
0.5
0.6
current / mA
Two readings taken on the meter at different times during an experiment are 0.13 mA and
0.47 mA.
By how much did the current really increase between taking the two readings?
A
85
0.30 mA
B
0.35 mA
C
0.40 mA
D
0.44 mA
Four identical rods have a square cross-section. The rods are placed side by side and their total
width is measured with vernier calipers, as shown.
vernier calipers
1
four square
cross-section rods
The measurement is (8.4 ± 0.1) mm and the zero reading on the calipers is (0.0 ± 0.1) mm.
What is the width of one rod?
A
(2.10 ± 0.025) mm
B
(2.10 ± 0.05) mm
C
(2.1 ± 0.1) mm
D
(2.1 ± 0.2) mm
34
86
A student measures the time T for one complete oscillation of a pendulum of length l.
Her results are shown in the table.
l/m
T/s
0.420 ± 0.001
1.3 ± 0.1
She uses the formula
T = 2π
l
g
to calculate the acceleration of free fall g.
What is the best estimate of the percentage uncertainty in the value of g?
A
87
B
0.02%
C
4%
D
8%
16%
The diagram shows two complete pulses on the screen of a cathode-ray oscilloscope. A grid of
1 cm squares covers the screen. The time-base setting is 1 µs cm–1.
1 cm
How long does each pulse last?
A
2 µs
B
3 µs
C
4 µs
D
6 µs
88
Measurements are subject to systematic error and random error.
Which measurements have high accuracy and low precision?
89
A
high random error and high systematic error
B
high random error and low systematic error
C
low random error and high systematic error
D
low random error and low systematic error
The density of the material of a coil of thin wire is to be found.
Which set of instruments could be used to do this most accurately?
A
metre rule, protractor, spring balance
B
micrometer, metre rule, top-pan balance
C
stopwatch, newton-meter, vernier calipers
D
tape measure, vernier calipers, lever balance
35
90
A cylindrical tube rolling down a slope of inclination θ moves a distance L in time T. The equation
relating these quantities is
a 2
= QT 2 sin θ
L 3 +
P
where a is the internal radius of the tube and P and Q are constants.
Which row gives the correct units for P and for Q?
91
P
Q
A
m2
m2 s–2
B
m2
m s–2
C
m2
m3 s–2
D
m3
m s–2
Variables x and y are related by the equation y = p – qx where p and q are constants.
Values of x and y are measured experimentally. The results contain a systematic error.
Which graph best represents these results?
A
y
p
0
p
0
x
0
C
y
x
0
D
y
p
p
0
B
y
0
x
0
0
x
36
92
The Young modulus of the material of a wire is to be found. The Young modulus E is given by the
equation below.
E=
4Fl
πd 2 x
The wire is extended by a known force and the following measurements are made.
Which measurement has the largest effect on the uncertainty in the value of the calculated
Young modulus?
measurement
symbol
value
A
length of wire before force applied
l
2.043 ± 0.002 m
B
diameter of wire
d
0.54 ± 0.02 mm
C
force applied
F
19.62 ± 0.01 N
D
extension of wire with force applied
x
5.2 ± 0.2 mm
© University of Cambridge Local Examinations Syndicate 2003
37
Question
Number
Key
Question
Number
Key
1
2
C
A
21
22
B
A
3
4
5
B
C
C
23
24
25
B
B
6
7
C
D
26
27
A
B
8
9
10
A
D
C
28
29
30
C
C
D
11
12
A
D
31
32
B
D
13
14
15
C
A
C
33
34
35
D
A
C
16
17
C
D
36
37
D
B
18
19
20
D
B
B
38
39
40
B
B
B
41
42
A
C
46
47
D
B
43
44
45
B
C
A
48
49
50
A
D
B
51
52
A
C
56
57
C
D
53
54
55
D
D
D
58
59
60
B
C
D
61
62
D
D
66
67
B
C
63
64
65
B
C
D
68
69
70
C
C
B
71
72
D
A
76
77
A
B
73
74
75
D
D
D
78
79
80
C
C
D
81
82
B
B
86
87
D
A
83
84
85
C
A
B
88
89
90
B
B
B
91
A
92
B
B
38
ASSIGNMENT # 2 -- AS
(MEASUREMENTS & UNCERTAINTIES)
Theory
39
STRUCTURED QUESTIONS
1
The uncalibrated scale and the pointer of a meter are shown in Fig. 1.1.
uncalibrated
scale
Fig. 1.1
The pointer is shown in the zero position.
The meter is to be used to indicate the volume of fuel in the tank of a car.
A known volume V of fuel is poured into the tank and the deflection θ of the pointer is noted.
Fig. 1.2 shows the variation with θ of V.
80
V
/103 cm3
60
40
20
0
0
20
40
Fig. 1.2
60
80
θ /°
100
40
(a) On Fig. 1.1,
(i)
calibrate the scale at 20 × 103 cm3 intervals,
[2]
(ii)
mark a possible position for a volume of 1.0 × 105 cm3.
[1]
(b) Suggest one advantage of this scale, as compared with a uniform scale, for measuring
fuel volumes in the tank of the car.
..........................................................................................................................................
......................................................................................................................................[1]
[Turn over
41
2
(a) Distinguish between systematic errors and random errors.
systematic errors .............................................................................................................
..........................................................................................................................................
random errors ..................................................................................................................
..................................................................................................................................... [2]
(b) A cylinder of length L has a circular cross-section of radius R, as shown in Fig. 1.1.
R
L
Fig. 1.1
The volume V of the cylinder is given by the expression
V = πR 2L .
The volume and length of the cylinder are measured as
V = 15.0 ± 0.5 cm3
L = 20.0 ± 0.1 cm.
Calculate the radius of the cylinder, with its uncertainty.
radius = ........................ ± ........................ cm [5]
[Turn over
42
3
(b) The mass of a cube of aluminium is found to be 580 g with an uncertainty in the
measurement of 10 g. Each side of the cube has a length of (6.0 ± 0.1) cm.
Calculate the density of aluminium with its uncertainty. Express your answer to an
appropriate number of significant figures.
density = ................ ± ................ g cm–3 [5]
43
4
The volume of fuel in the tank of a car is monitored using a meter as illustrated in Fig. 1.1.
FUEL
¼
½
¾
1
0
Fig. 1.1
The meter has an analogue scale. The meter reading for different volumes of fuel in the tank
is shown in Fig. 1.2.
60
volume
/ litre
50
40
30
20
10
0
0
empty
¼
½
¾
1
full
meter reading
Fig. 1.2
The meter is calibrated in terms of the fraction of the tank that remains filled with fuel.
44
(a) The car uses 1.0 litre of fuel when travelling 14 km. The car starts a journey with a full
tank of fuel.
(i)
Calculate the volume of fuel remaining in the tank after a journey of 210 km.
volume = ...................................... litres [2]
(ii)
Use your answer to (i) and Fig. 1.2 to determine the change in the meter reading
during the 210 km journey.
from full to ............................................... [1]
(b) There is a systematic error in the meter.
(i)
State the feature of Fig. 1.2 that indicates that there is a systematic error.
..................................................................................................................................
............................................................................................................................ [1]
(ii) Suggest why, for this meter, it is an advantage to have this systematic error.
..................................................................................................................................
............................................................................................................................ [1]
[Turn over
45
5
A simple pendulum may be used to determine a value for the acceleration of free fall g.
Measurements are made of the length L of the pendulum and the period T of oscillation.
The values obtained, with their uncertainties, are as shown.
T = (1.93 ± 0.03) s
L = (92 ± 1) cm
(a) Calculate the percentage uncertainty in the measurement of
(i)
the period T,
uncertainty = ............................................ % [1]
(ii)
the length L.
uncertainty = ............................................ % [1]
46
(b) The relationship between T, L and g is given by
g=
42L
.
T2
Using your answers in (a), calculate the percentage uncertainty in the value of g.
uncertainty = ............................................ % [1]
(c) The values of L and T are used to calculate a value of g as 9.751 m s–2.
(i)
By reference to the measurements of L and T, suggest why it would not be correct
to quote the value of g as 9.751 m s–2.
..................................................................................................................................
............................................................................................................................ [1]
(ii)
Use your answer in (b) to determine the absolute uncertainty in g.
Hence state the value of g, with its uncertainty, to an appropriate number of
significant figures.
g = .......................... ± ........................ m s–2 [2]
[Turn over
47
6
A metal wire has a cross-section of diameter approximately 0.8 mm.
(a) State what instrument should be used to measure the diameter of the wire.
...................................................................................................................................... [1]
(b) State how the instrument in (a) is
(i)
checked so as to avoid a systematic error in the measurements,
..................................................................................................................................
.............................................................................................................................. [1]
(ii)
used so as to reduce random errors.
..................................................................................................................................
..................................................................................................................................
.............................................................................................................................. [2]
[Turn over
48
7
A digital voltmeter with a three-digit display is used to measure the potential difference across
a resistor. The manufacturers of the meter state that its accuracy is ±1% and ±1 digit.
The reading on the voltmeter is 2.05 V.
(a) For this reading, calculate, to the nearest digit,
(i)
a change of 1% in the voltmeter reading,
change = ..............................................V [1]
(ii)
the maximum possible value of the potential difference across the resistor.
maximum value = ..............................................V [1]
(b) The reading on the voltmeter has high precision. State and explain why the reading may
not be accurate.
..........................................................................................................................................
..........................................................................................................................................
......................................................................................................................................[2]
[Turn over
49
8
(a) State the appropriate instruments used to make each of these measurements.
(i)
length
............................................................................................................................. [1]
(ii)
diameter
............................................................................................................................. [1]
(iii)
resistance
............................................................................................................................. [1]
(b) (i)
Show that the resistivity of the metal is calculated to be 4.86 × 10–7 Ω m.
[2]
(ii)
Calculate the uncertainty in the resistivity.
(c) Use the answers in (b) to express the resistivity with its uncertainty to the appropriate
number of significant figures.
resistivity = .......................................... ± .......................................... Ω m [1]
uncertainty = ± .......................................... Ω m [4]
50
4
9
(a) For each of the following, tick [ ✓] one box to indicate whether the experimental technique
would reduce random error, systematic error or neither. The first row has been completed
as an example.
random error
systematic error
keeping your eye
in line with the
scale and the
liquid level for a
single reading of
a thermometer
neither
✓
averaging many
readings of the
time taken for a
ball to roll down a
slope
using a linear
scale on an
ammeter
correcting for
a non-zero
reading when a
micrometer screw
gauge is closed
[2]
(b) The measurement of a particular time interval is repeated many times. The readings are
found to vary. The results are shown in Fig. 1.1.
number
8
of readings
6
4
2
0
10.0
10.2
10.4
10.6
reading of time interval / s
Fig. 1.1
The true value of the time interval is 10.1 s.
10.8
51
(i)
State how the readings on Fig. 1.1 show the presence of
1.
a systematic error,
..................................................................................................................................
.............................................................................................................................. [1]
2.
a random error.
..................................................................................................................................
.............................................................................................................................. [1]
(ii)
State the expected changes to Fig. 1.1 for experimental measurements that are
1.
more accurate,
..................................................................................................................................
.............................................................................................................................. [1]
2.
more precise.
..................................................................................................................................
.............................................................................................................................. [1]
[Turn over
52
10
The volume V of liquid flowing in time t through a pipe of radius r is given by the equation
V
π Pr 4
=
t
8Cl
where P is the pressure difference between the ends of the pipe of length l, and C depends
on the frictional effects of the liquid.
An experiment is performed to determine C. The measurements made are shown in Fig. 1.1.
V
/ 10–6 m3 s–1
t
P / 103 N m–2
r / mm
l /m
1.20 ± 0.01
2.50 ± 0.05
0.75 ± 0.01
0.250 ± 0.001
Fig. 1.1
(a) Calculate the value of C.
C = ..................................... N s m–2 [2]
(b) Calculate the uncertainty in C.
uncertainty = ..................................... N s m–2 [3]
(c) State the value of C and its uncertainty to the appropriate number of significant figures.
C = ........................................... ± ........................................... N s m–2 [1]
[Turn over
53
11
Energy is stored in a metal wire that is extended elastically.
(a) Explain what is meant by extended elastically.
..........................................................................................................................................
..................................................................................................................................... [2]
(b) Show that the SІ units of energy per unit volume are kg m–1 s–2.
[2]
(c) For a wire extended elastically, the elastic energy per unit volume X is given by
X = Cε 2E
where C is a constant,
ε is the strain of the wire,
and E is the Young modulus of the wire.
Show that C has no units.
[3]
[Turn over
54
12
A source of radio waves sends a pulse towards a reflector. The pulse returns from the
reflector and is detected at the same point as the source. The emitted and reflected pulses
are recorded on a cathode-ray oscilloscope (c.r.o.) as shown in Fig. 2.1.
1 cm
1 cm
Fig. 2.1
The time-base setting is 0.20 µs cm–1.
(a) Using Fig. 2.1, determine the distance between the source and the reflector.
distance = ............................................. m [4]
(b) Determine the time-base setting required to produce the same separation of pulses on
the c.r.o. when sound waves are used instead of radio waves.
The speed of sound is 300 m s–1.
..........................................................................................................................................
..........................................................................................................................................
...................................................................................................................................... [3]
[Turn over
55
The time T for a satellite to orbit the Earth is given by
T=
3
c KR m
M
where R is the distance of the satellite from the centre of the Earth,
M is the mass of the Earth,
and K is a constant.
(a) Determine the SI base units of K.
SI base units of K ................................................ [2]
(b) Data for a particular satellite are given in Fig. 2.1.
quantity
measurement
uncertainty
T
8.64 × 104 s
± 0.5%
R
4.23 × 107 m
± 1%
M
6.0 × 1024 kg
± 2%
Fig. 2.1
Ka
s
hi
fR
af
K = ....................................... ± .................................... SI units [4]
iq
ue
Calculate K and its actual uncertainty in SI units.
Si
r
13
[Turn over
56
14
A coin is made in the shape of a thin cylinder, as shown in Fig. 2.1.
diameter
thickness
Fig. 2.1
Fig. 2.2 shows the measurements made in order to determine the density ρ of the material used to
make the coin.
quantity
measurement
uncertainty
mass
9.6 g
± 0.5 g
thickness
2.00 mm
± 0.01 mm
diameter
22.1 mm
± 0.1 mm
Fig. 2.2
(a) Calculate the density ρ in kg m–3.
ρ = ...............................................kg m–3 [3]
(b) (i)
Calculate the percentage uncertainty in ρ.
percentage uncertainty = ......................................................... [3]
(ii)
State the value of ρ with its actual uncertainty.
ρ = ........................................................ ± ........................................... kg m–3 [1]
[Turn over
57
15
(a) Define pressure.
.............................................................................................................................................. [1]
(b) A cylinder is placed on a horizontal surface, as shown in Fig. 2.1.
diameter
cylinder
Fig. 2.1
The following measurements were made on the cylinder:
mass = 5.09 ± 0.01 kg
diameter = 9.4 ± 0.1 cm.
(i)
Calculate the pressure produced by the cylinder on the surface.
pressure = .................................................... Pa [3]
(ii)
Calculate the actual uncertainty in the pressure.
actual uncertainty = .................................................... Pa [3]
(iii)
State the pressure, with its actual uncertainty.
pressure = ........................................... ± ........................................... Pa [1]
[Turn over
58
16
A microphone detects a musical note of frequency f. The microphone is connected to a cathoderay oscilloscope (c.r.o.). The signal from the microphone is observed on the c.r.o. as illustrated in
Fig. 2.1.
1.0 cm
1.0 cm
Fig. 2.1
The time-base setting of the c.r.o. is 0.50 ms cm–1. The Y-plate setting is 2.5 mV cm–1.
(a) Use Fig. 2.1 to determine
(i)
the amplitude of the signal,
amplitude = ................................................... mV [2]
(ii)
the frequency f,
f = .................................................... Hz [3]
(iii)
the actual uncertainty in f caused by reading the scale on the c.r.o.
actual uncertainty = .................................................... Hz [2]
(b) State f with its actual uncertainty.
f = ................................ ± ................................ Hz [1]
[Turn over
59
17 (ii) Data in SΙ units for the oscillations of X are shown in Fig. 1.2.
quantity
value
uncertainty
T
0.45
± 2.0%
l
0.892
± 0.2%
M
0.2068
± 0.1%
K
1.48 × 105
± 1.5%
Fig. 1.2
Calculate E and its actual uncertainty.
E = ..................................... ± ..................................... kg m–1 s–2 [4]
18
(b) The signal from a radio wave detector is recorded on the same c.r.o.
The wavelength of the radio waves is 1.5 × 103 m.
Determine the time-base setting required to display the same number of oscillations on the
c.r.o. as shown in Fig. 2.1.
time-base setting = ....................................... unit........................ [2]
[Turn over
60
19 A student uses a metre rule to measure the length of an elastic band before and
after stretching it. The lengths are recorded as
length of band before stretching, L0 = 50.0 0.1 cm
length of band after stretching, LS = 51.6 0.1 cm.
Determine:
(a) the change in length (LS L0), quoting your answer with its uncertainty,
(b) the fractional change in length, ,
(c) the uncertainty in your answer in (b).
61
ANSWERS
(a) (i) all positions (accept 20, 40, 60, 80) marked to within ±5°
positions are 40°, 70°, 90° and 102°
(-1 for each error or omission)
B2
(ii) allow 107° → 113°
(b) e.g. more sensitive at low volumes
(do not allow reference to ‘accuracy’)
[1]
B1
[2]
(b) 15 = π × R2 × 20
R = 0.4886 cm (accept any number of s.f.)
% uncertainty in V = 3.3 % (or 0.5/15)
% uncertainty in L = 0.5 % (or 0.1/20)
% uncertainty in R = 1.9 % (i.e. one half of the sum)
R = 0.489 ± 0.009 cm
C1
C1
C1
C1
A1
[5]
B1
(b) density = mass / volume .................................................................... C1
= 580 / 63 = 2.685 g cm-3 …(allow 2.68, 2.69, 2.7) ............. A1
% uncertainty in mass = (10 / 580) × 100 = 1.7% ..............................
% uncertainty in volume = 3 × (0.1 / 6) × 100 = 5.0% ........................
uncertainty in density = 0.18 g cm-3
density = 2.7 ± 0.2 g cm-3 ...................................................................
(answer 2.69 ± 0.09 g cm-3 scores 4 marks)
C1
C1
A1
[5]
(a) (i) car uses 210 / 14 = 15 litres of fuel .................................................................... C1
volume reading = 45 litres . ................................................................................. A1
[2]
(ii) from ‘full’ to ‘3/4’ mark ......................................................................................... B1
[1]
(b) (i) line/graph does not pass through (‘empty, 0) / there is an intercept ................... B1
(do not allow ‘non-linear’)
[1]
[1]
af
iq
(ii) (meter shows zero fuel when there is some left in the tank so)
acts as a ‘reserve’ ............................................................................................... B1
fR
[Total: 5]
hi
4
B1
Ka
s
3
[3]
(a) systematic: e.g. constant error (in all readings)
cannot be eliminated by averaging
error in measuring instrument
random: e.g.
readings scattered (equally) about true value
error due to observer
can be eliminated by averaging
(only if averaging not included for systematic)
Si
r
2
B1
ue
1
62
5
or
1.6%
…(not 1.5 or 2) ............................................ A1
[1]
or
1.1%
…(not 1.0 or 1) ............................................ A1
[1]
(b) answer of {(ii) + 2 × (i)} to any number of sig. fig.
either 4.2%
or
4.3% .................................................................................... A1
[1]
(c) (i) either the value has more significant figures than the data
or uncertainty of ±0.4 renders more than 2 s.f. meaningless)
......................... B1
[1]
(ii) uncertainty in g = ±0.41 / ±0.42 to any number of s.f. .................................... C1
g = (9.8 ± 0.4) m s-2 ........................................................................................ A1
[2]
(a) (i) either
1.55%
(ii) either
1.09%
[Total: 6]
6
7
(a) micrometer/screw gauge/digital callipers ……………………………………….
B1
[1]
(b)
(i) look/check for zero error …………………………………………………….
B1
[1]
(ii) take several readings ………………………………………………………..
around the circumference/along the wire ………………………………….
M1
A1
[2]
(i) 1% of ±2.05 is ±0.02
A1
[1]
(ii) max. value is 2.08 V
A1
[1]
M1
A1
[2]
(a)
(b) there may be a zero error/calibration error/systematic error
which makes all readings either higher or lower than true value
8
(b) (i) resistivity = RA / L
= [7.5 × π × (0.38 × 10–3)2 / 4] / 1.75
= 4.86 × 10–7 Ω m
(ii) (uncertainty in R =)
[0.2 / 7.5] × 100 = 2.7%
and (uncertainty in L =) [3 / 1750] × 100 = 0.17%
(uncertainty in A =)
2 × (0.01 / 0.38) × 100 = 5.3 %
total = 8.13%
uncertainty = 0.395 × 10–7 (Ω m)
(missing 2 factor in uncertainty in A, then allow max 3/4)
9
C1
M1
A0
[2]
C1
C1
C1
A1
[4]
(c) resistivity = (4.9 × 10–7 ± 0.4 × 10–7) Ω m
A1
[1]
(a) 2nd row random, 3rd row neither, 4th row systematic all correct
two correct scores 1 only
B2
(b) (i) 1.
2.
(ii) 1.
2.
[2]
systematic error: the average / peak is not the true value / the readings
are not centred around the true value
B1
[1]
random error: readings have positive and negative values around the
peak value / values are scattered / wide range
B1
[1]
accurate: peak / average value moves towards the true value
B1
[1]
precise: lines are closer together / sharper peak
B1
[1]
63
V πP r4
10 (a) t = 8 C l
C = [π × 2.5 × 103 × (0.75 × 10–3)4] / (8 × 1.2 × 10–6 × 0.25)
= 1.04 × 10–3 N s m–2
(b) 4 × %r
%C = %P + 4 × %r + %V/t + %l
= 2% + 5.3% + 0.83% + 0.4% (= 8.6%)
∆C = ± 0.089 × 10–3 N s m–2
(c)
11
C = (1.04 ± 0.09) × 10–3 N s m–2
(a) the wire returns to its original length
(not ‘shape’)
[2]
C1
A1
A1
[3]
A1
[1]
M
A1
[2]
(b) energy: N m / kg m2 s–2 and volume m3
energy / volume: kg m2 s–2 / m3
energy / volume: kg m–1 s–2
C1
M1
A0
[2]
(c) ε has no units
E: kg m s–2 m–2
units of RHS: kg m–1 s–2 = LHS units / satisfactory conclusion to show C has
no units
B1
M1
A1
[3
(a) d = v × t
t = 0.2 × 4 (allow t = 0.2 × 2)
d = 3 × 108 × 0.8 × 10–6
OR
3 × 108 × 0.4 × 10–6
d = 240 m hence distance from source to reflector = 120 m
C1
C1
C1
A1
[4]
when the load is removed
12
C1
A1
(b) speed of sound 300 cf speed of light 3 × 108
sound slower by factor of 106
time base setting 0.2 s cm–1
13
OR time = 240 / 300 (= 0.8)
OR time = 120 / 300 (= 0.4)
OR time for one division 0.8 / 4
OR time for one division 0.4 / 2
[unit required]
(a) SI units for T: s, R: m and M: kg (or seen clearly in formula)
s2kg
K = T2 M / R3 units: s2 kg m–3
(allow s2 kg / m3 or
)
m3
(b) % uncertainty in K: 1% (for T) + 3% (for R) + 2% (for M) OR = 6%
K = [(86400)2 × 6 × 1024] / (4.23 × 107)3 = 5.918 × 1011
6% of K = 0.355 × 1011
K = (5.9 ± 0.4) × 1011 (SI units) correct power of ten required for both
[incorrect % value then max. 1]
C1
C1
A1
[3]
C1
A
[2]
C1
C1
C1
A1
[4]
64
14 (a) ρ = m / V
V = (π d 2 / 4) × t = 7.67 × 10–7 m3
ρ = (9.6 × 10–3) / [π(22.1/2 × 10–3)2 × 2.00 × 10–3]
ρ = 12513 kg m–3 (allow 2 or more s.f.)
(b) (i) ∆ρ / ρ = ∆m / m + ∆t / t + 2∆d / d
= 5.21% + 0.50% + 0.905% [or correct fractional uncertainties]
= 6.6% (6.61%)
(ii) ρ = 12 500 ± 800 kg m–3
15
(a) pressure = force / area (normal to the force) [clear ratio essential]
(b) (i) P = mg / A = (5.09 × 9.81) / A
A = (πd2 / 4) = π × (9.4 × 10–2)2 / 4 (= 0.00694 m2)
C1
C1
A1
[3]
C1
C1
A1
[3]
A1
[1]
P = 49.93 / 0.00694 = 7200 (7195) Pa (minimum of 2 s.f. required)
(ii) ∆P / P = ∆m / m + 2∆d / d
= 0.01 / 5.09 + (2 × 0.1) / 9.4 (= 0.0020 + 0.021 or 2.3%)
∆P = 170 (165 to 167) Pa
a
(iii) P = 7200 ± 200 Pa
a
16
(a) (i) amplitude scale reading 2.2 (cm)
amplitude = 2.2 × 2.5 = 5.5 mV
(ii) time period scale reading = 3.8 (cm)
time period = 3.8 × 0.5 × 10–3 = 0.0019 (s)
frequency f = 1 / 0.0019 = 530 (526) Hz
(iii) uncertainty in reading = ± 0.2 in 3.8 (cm) or 5.3% or 0.2 in 7.6 (cm)
or 2.6% [allow other variations of the distance on the x-axis]
actual uncertainty = 5.3% of 526 = 27.7 or 28 Hz
or 2.6% of 526 = 13 or 14
(b) frequency = 530 ± 30 Hz or 530 ± 10 Hz
z
17
(ii) % uncertainty in E = 4% (for T 2) + 0.6% (for l 3) + 0.1% (for M) + 3% (for K 2)
= 7.7%
5 2
E = [(1.48 × 10 ) × 0.2068 × (0.892)3] / (0.45)2
= 1.588 × 1010
7.7% of E = 1.22 × 109
E = (1.6 ± 0.1) × 1010 kg m–1 s–2
18
(b) 1500 = 3.0 × 108 × 4 × time-base setting or T = 5 × 10–6 s
time-base setting = 1.3 (1.25) µs cm–1
19
(a) 1.6 0.2 cm (b) 0.032 (c) 0.004
C1
A1
[2]
65
Learning outcomes
Candidates should be able to:
(a) use techniques for the measurement of length, volume, angle, mass, time, temperature and
electrical quantities appropriate to the ranges of magnitude implied by the relevant parts of the
syllabus. In particular, candidates should be able to:
• measure lengths using a ruler, vernier scale and micrometer(to be done in lab)
• measure weight and hence mass using spring and lever balances(to be done in lab--mostly)
• measure an angle using a protractor(to be done in lab)
• measure time intervals using clocks, stopwatches and the calibrated time-base of a cathode-ray
oscilloscope (c.r.o.)
• measure temperature using a thermometer as a sensor(to be done in lab)
• use ammeters and voltmeters with appropriate scales(to be done in lab)
• use a galvanometer in null methods (to be done in electricity chapter)
• use a cathode-ray oscilloscope (c.r.o.)
(b) use both analogue scales and digital displays(to be done in lab)
(c) use calibration curves
(d) show an understanding of the distinction between systematic errors (including zero errors) and
random errors
(e) show an understanding of the distinction between precision and accuracy
(f) assess the uncertainty in a derived quantity by simple addition of actual, fractional or percentage
uncertainties (a rigorous statistical treatment is not required).
__________________________________________________________________________________
UNCERTAINTIES: a quantitative measure of how much your measured values deviate from a standard
or expected value.
ERRORS: are the uncertainties in measured quantities which arise from different sources due to either
limitations of observer, measuring instrument used or method of the experiment used.
1. FORMS OF ERRORS:
(i) Absolute Errors: they are written in the form : ±x units,always written to 1sf.
(ii) Fractional Errors: they are written in the form : ±x / x, has no units
(iii) Percentage Errors: they are written in the form : ±(x / x)100, has no units,
Fractional or %age errors are useful to indicate the suitability of chosen instrument. More the error
less likely for that instrument to be selected.
2. TYPES OF ERRORS:
(i) Systematic Errors: are the constant errors which cause all results to be incorrect by roughly the
same amount in the same direction i.e. either higher or lower than actual. For example: zero errors
in instruments, extra counts due to to background radiations, wrong assumptions, reaction time of
experimenter, incorrect markings on any scale,
Systematic errors can be eliminated COMPLETELY
They CANNOT be minimized by taking average of many readings taken.
SUMMARY ERRORS & UNCERTAINITES
66
Ways To Minimize: 1. Use another set of apparatus .2. Operate the system in systematic way to
predict the error .3. Use of calibration curves to predict the error.
On a graph, S.Errors are represented by: (i) either y-intercept or x-intercept (ii) Difference
between the actual value & average value. (see class notes for examples)
(ii) Random Errors: are the errors with different magnitudes and signs in repeated readings. They
occur due to our inability to obtain the true value. For example: variations in external physical
conditions, irregularity of the quantity to be measured (variations in diameter of wire), inability of
experimenter(e.g counting oscillations), parallax error, taking readings which changes with time,
fluctuations in the last digit of digital meters.
Random errors cannot be eliminated completely, they can be minimized.
They can be minimized by taking average of many readings taken.
Ways To Minimize: 1. Take large no of readings and average them out .2. Operate the system
periodically.
On a graph, R.Errors are represented by: Scatter of points or deviation (see class notes for
examples)
3. COMPOUND ERRORS: Results of an experiment is often obtained by combining few quantities. The
computation of error depends upon the type of the equations used in the process. The rules for the
computations of errors are:
i. Addition or Subtraction: If
R = R2 ± R1 then the error is calculated by :
Then R = ± (R2 + R1)
ii. Multiplication:
If
R = a × b then the error is calculated by :
Then
iii. Division:
If
=±
R = a ÷ b then the error is calculated by :
Then
=±
iv. Constant Multiplied by a Variable:
Then
v. Power of a variable:
=±
If R = 2 × a then the error is calculated by :
R = ap, where p is a constant, then the error is calculated by :
If
Then
=±
vi. General Case (Combination of any or all of above):
If R =
, where p & q are constants, then the error is calculated by :
SUMMARY ERRORS & UNCERTAINITES
67
Then
=±
PRECISION: It refers to the extent or the limit of sensitivity of a given measuring instrument to
obtain the readings of the physical quantity being measured. THIS MEANS The precision of a
measuring tool is related to the size of its measurement increments. The smaller the measurement
increment, the more precise the tool.
Precision is given by the deviation of results from their average of set of results.
Precision tells us how close the readings are to one another; they all may be far from actual
value.
Precision α
, more the deviation less precise the readings are & vice versa.
This means Precision α
Precision can be improved by using a magnifying glass for readings.
4. ACCURACY: It refers to how close the readings are to the actual value.
Accuracy of a measurement is given by the percentage error.
Accuracy α
, more the %age error less accurate the readings are & vice versa.
Accuracy can be improved by using a more precise instrument .i.e which has smaller least count.
This means Accuracy α
SUMMARY ERRORS & UNCERTAINITES
0
You can add this document to your study collection(s)
Sign in Available only to authorized usersYou can add this document to your saved list
Sign in Available only to authorized users(For complaints, use another form )