CIS NOTES 09-26-2025
Terminating Ethernet Keystone Jack (Female Part):
-
Grab wire.
Take wire and use a Date Sure Strip tool (Brand: Paladin Tools) to strip the wire of its
insulation.
Once striped of its insulation, take scissors and cut the all-white wire.
After all-white wire is cut, unravel the rest of the wires using the insulation piece cut off
from earlier.
All unraveling all the wires, grab the AMP NETCONNECT tool, use the small tool, open
it and put the wire in the hole slot.
After the wire is in the hole, match the wire colors with the colors on the part (For this
case, B side).
After all the wires are aligned correctly, take the ethernet keystone jack, and align it with
the wires color order and press down.
Once jack is secure, insert it into the other AMP NETCONNECT tool, matching the hole
with piece that sticks out, and having the wire lie down in wire slot.
Once all aligned, press down on the tool a few times.
Once secured, take part out of the tool, take away the excess wire, push the cable in the
direction of the jack and open the small tool.
Afterwards, you should have a terminated cable with an ethernet jack on the end.
Also, don’t forget to attach the clear black piece to keep it secured.