Declared as Deemed-to-be-University u/s 3 of the UGC Act 1956 Study of Soiling Loss on Photovoltaic Modules with Artificially Deposited Dust of Different Gravimetric Densities and Compositions Collected from Different Countries A Project Report Submitted by ANIRUDDHA BARAI 19 BTREE027 BISHNU THAPA 19BTREE 029 JIGDREL WANGCHUK 19 BTREE034 SANTULLAH SAMI 19 BTREE046 in Partial fulfilment of the Requirements for the degree of BACHELOR OF TECHNOLOGY in ELECTRICAL AND ELECTRONICS ENGINEERING FACULTY OF ENGINEERING AND TECHNOLOGY JAIN (DEEMED TO BE UNIVERSITY) KANAKAPURA, KARNATAKA – 562112 MAY 2023 DECLARATION We, Aniruddha Barai (19BTREE027), Bishnu Thapa (19BTREE029), Jigdrel Wangchuk (19BTREE034), Santullah Sami (19BTREE046), are students of eighth semester at B.Tech in Electrical and Electronics Engineering at Faculty of Engineering & Technology, JAIN(Deemedto-be-University), hereby declare that the project titled “Study of Soiling Loss on Photovoltaic Modules with Artificially Deposited Dust of Different Gravimetric Densities and Compositions Collected From Different Countries” has been carried out by us and submitted in partial fulfilment for the award of degree in Bachelor of Technology in Electrical and Electronics Engineering during the academic year 2022-2023. Further, the matter presented in the project has not been submitted previously by anybody for the award of any degree or any diploma to any other University, to the best of our knowledge and faith. Signature Aniruddha Barai USN: 19BTREE027 Bishnu Thapa USN: 19BTREE029 Jigdrel Wangchuk USN: 19BTREE034 Santullah Sami USN:19BTREE046 Place: Bangalore Date: BONAFIDE CERTIFICATE This is to certify that the project work entitled “STUDY OF SOILING LOSS ON PHOTOVOLTAIC MODULES WITH ARTIFICIALLY DEPOSITED DUST OF DIFFERENT GRAVIMETRIC DENSITIES AND COMPOSITIONS COLLECTED FROM DIFFERENT COUNTRIES” is a bonafide work carried out by ANIRUDDHA BARAI (19BTREE027), BISHNU THAPA (19BTREE029), JIGDREL WANGCHUK (19BTREE034), SANTULLAH SAMI (19BTREE046) partial fulfilment for the award of degree in Bachelor of Technology in Electrical and Electronics Engineering during year 2022 – 2023. SAVITHA R. Assistant Professor Project guide Dept. of EEE, FET-JU Name of the Examiner 1. 2. Dr. PRADEEPA. P Head of the department Department of EEE, FET- Designation, Affiliation Dr. S .A. HARIPRASAD Director, FET Jain Deemed to be University Signature Date ACKNOWLEDGEMENTS The satisfaction and euphoria that accompany the successful completion of any task would be incomplete without mention of people who made it possible, whose constant guidance and encouragement crowned our effects with success. In particular, we would like to thank Dr. S A Hariprasad, Director, Faculty of Engineering and Technology, Jain (Deemed-to-be-University) for his constant encouragement and expert advice. It is a matter of immense pleasure to express my sincere thanks to Dr. P. Pradeepa, Professor and Head, Dr. G. Ezhilarasan, Professor and Programme Head, Department of Electrical and Electronics Engineering, Faculty of Engineering and Technology, Jain (Deemed-to-be University) for providing right academic guidance that made my task possible. We would like to thank our project guide Savitha R., Assistant Professor, Department of Electrical and Electronics Engineering, Faculty of Engineering and Technology, Jain (Deemed-tobeUniversity) for the constant encouragement, continuous guidance and invaluable support. We would like to thank our project coordinator Dr. P. Kishore Kumar, Associate Professor, Department of Electrical and Electronics Engineering, Faculty of Engineering and Technology, Jain (Deemed-to-be-University) for the constant support and guidance to reach the targeted task. We are grateful to our institution, Faculty of Engineering and Technology, Jain (Deemed-to-beUniversity) with its ideals and inspirations for having provided us with the facilities, which has made this, project a success. Finally, we thank our parents and friends for their moral support. ANIRUDDHA BARAI (19BTREE027) BISHNU THAPA (19BTREE029) JIGDREL WANGCHUK (19BTREE034) SANTULLAH SAMI (19BTREE046) Study of Soiling Loss on Photovoltaic Modules with Artificially Deposited Dust of Different Gravimetric Densities and Compositions Collected From Different Countries. 2022-2023 ABSTRACT The evaluation of soiling loss on PV modules is a time-consuming and expensive process. Dust accumulation on module surfaces can significantly impact their performance and energy output. Traditionally, researchers rely on field data collection from operational PV systems, which is labour-intensive, costly, and prone to uncertainties. To address these challenges, this study proposes a novel approach using laboratory-based soiling evaluation with artificially deposited dust samples. The objective is to develop a cost-effective and efficient methodology for predicting soiling loss associated with different dust properties. Dust samples are collected from four countries Nepal, Bhutan, Bangladesh, and India to simulate real-world soiling conditions. A low-cost artificial dust deposition technique is utilized to ensure controlled dust deposition on module surfaces. This technique enables the study of different dust types and their impact on PV module performance. Laboratory experiments are conducted to measure and analyze the soiling loss of PV modules under controlled conditions. By correlating the characteristics of the collected dust samples with the observed soiling loss, predictive models are developed. These models allow for the estimation of performance degradation in specific geographical locations based on dust properties. This approach offers a cost-effective alternative to field measurements and provides valuable insights for solar energy planning and maintenance strategies. The findings revealed that Nepal experienced maximum power loss (61.03%), attributed to higher soil moisture content (3.3g). In contrast, India exhibited the minimum power loss (45.6%) with lower soil moisture content (0.6g). The results emphasize the impact of soil moisture on dust adhesion and soiling loss. Implementing appropriate cleaning strategies considering regional factors is crucial for maximizing PV system performance. Keywords: Soiling loss, PV system, dust, Solar Department of EEE, FET-JU TABLE OF CONTENTS CHAPTER CONTENTS Page No. Abstract i List of Figures ii List of Table iii List of Symbols & Abbreviation iv CHAPTER 1 Introduction. 08 1.1 Overview 08 Literature Review 09 Objectives and Methodology 12 3.1 Objectives 12 3.2 Methodology 12 CHAPTER 2 CHAPTER 3 3.2.1 Existing Methodology 12 3.2.2 Proposed Methodology 13 3.3 Resources EEE DEPARTMENT, FET-JU 15 3.3.1 Solar Panel 15 3.3.2 Multimeter 17 3.3.3 Muffle Furnace 19 3.3.4 Weighting Scale 21 3.3.5 Quartz Crucible 21 3.3.6 Beakers 23 Study of Soiling Loss on Photovoltaic Modules with Artificially Deposited Dust of Different Gravimetric Densities and Compositions Collected From Different Countries. 2022-2023 3.3.7 Lab Spoon 25 3.3.8 Soil Sample Region 26 CHAPTER 4 Results and Discussion 37 Conclusion 40 Future Scope 41 References v Annexure vi Appendix vii Department of EEE, FET-JU Study of Soiling Loss on Photovoltaic Modules with Artificially Deposited Dust of Different Gravimetric Densities and Compositions Collected From Different Countries. 2022-2023 LIST OF FIGURES Fig. No Description of figures 3.1 Existing Methodology 3.2 Proposed Methodology 3.3 Solar panel with specifications 10W, 21V, and 0.65A 3.4 Solar panel construction and working principle 3.5 A digital multimeter with its probes and front panel 3.6 Muffle furnace -1100° 3.7 Shimadzu BL220H 3.8 High Temperature Quartz Crucible 3.9 ML Beaker 3.10 Lab spoons 3.11 Working Process 3.12 Solar rating before test 3.13 VI curve under normal condition 3.14 Measuring the amount of soils 3.15 Effect of Bhutan soil on solar rating (V x I) 3.16 VI curve for Bhutan soil sample 3.17 Effect of Indian soil on solar rating (V x I) 4 Department of EEE, FET-JU Study of Soiling Loss on Photovoltaic Modules with Artificially Deposited Dust of Different Gravimetric Densities and Compositions Collected From Different Countries. 3.18 VI curve for Indian soil sample 3.19 Effect of Bangladesh soil on solar rating (V x I 3.20 VI curve for Bangladesh soil sample 3.21 Effect of Nepal soil on solar rating (V x I) 3.22 VI curve for Nepal soil sample 3.23 Muffle furnaces at 150°C for 24 hours 3.24 calculate the weight after muffle furnace. 4.1 VI Curve in bar graph 5 Department of EEE, FET-JU 2022-2023 Study of Soiling Loss on Photovoltaic Modules with Artificially Deposited Dust of Different Gravimetric Densities and Compositions Collected From Different Countries. 2022-2023 LIST OF TABLES Table No. Description 4.1 PV module performance data 4.2 Weight of soil samples before and after removing moisture 6 Department of EEE, FET-JU Study of Soiling Loss on Photovoltaic Modules with Artificially Deposited Dust of Different Gravimetric Densities and Compositions Collected From Different Countries. 2022-2023 LIST OF SYMBOLS AND ABBREVIATION PV Photovoltaic ROTA Renewable Energy Outdoor Testing Area NTT Nusa Tenggara Timur DC Direct Current AC Alternating Current RTU Remote Terminal Unit SCADA Supervisory Control and Data Acquisition LCD Liquid Crystal Display COM Commercial DUT Device Under Test PTFE Poly tetrafluoroethylene V Voltage W Watt A Ampere 7 Department of EEE, FET-JU Study of Soiling Loss on Photovoltaic Modules with Artificially Deposited Dust of Different Gravimetric Densities and Compositions Collected From Different Countries. 2022-2023 CHAPTER 1 INTRODUCTION 1.1 OVERVIEW The increasing global demand for clean and sustainable energy sources has led to a significant surge in the deployment of solar photovoltaic (PV) systems. Solar energy has emerged as a promising renewable energy source, offering significant potential for mitigating climate change and reducing dependence on fossil fuels. PV modules, which convert sunlight into electricity, play a crucial role in harnessing solar energy. However, the performance of PV modules can be significantly affected by various environmental factors, such as dust deposition on their surfaces. Soiling, the accumulation of dust and other particulate matter on PV module surfaces, is a widespread issue that can lead to a decrease in their energy output. Dust deposition reduces the amount of sunlight reaching the PV cells, resulting in decreased efficiency and power generation. The severity of soiling varies depending on geographical location, local climate conditions, and the characteristics of the deposited dust. Understanding the impact of dust deposition on PV modules and developing effective cleaning strategies are essential for maximizing the energy output and overall performance of solar power systems. The reduction in power generation due to dust deposition can lead to financial losses for PV system owners and operators. Moreover, in regions heavily dependent on solar energy, such as remote areas and developing countries, the performance degradation caused by soiling can have severe implications for the reliability and stability of the power supply. To address this issue, it is crucial to gain insights into the composition and characteristics of the dust particles responsible for soiling. By studying the variations in dust composition and its impact on PV module performance, researchers and industry professionals can develop targeted mitigation strategies to minimize the effects of soiling. In order to comprehensively understand the impact of dust deposition on PV modules, we collected and analyzed soil samples from four different countries. The four countries chosen for this study includes Bhutan, Bangladesh, Nepal and India. Each country offers unique insights into the challenges posed by dust deposition and provides valuable data for comparison and analysis. The selection of these countries allows for the examination of diverse environmental conditions and variations in dust composition, which are essential factors influencing the severity of soiling and its effect on PV module performance. 8 Department of EEE, FET-JU Study of Soiling Loss on Photovoltaic Modules with Artificially Deposited Dust of Different Gravimetric Densities and Compositions Collected From Different Countries. 2022-2023 CHAPTER 2 LITERATURE REVIEW Wasim Javed, et.al (2021) In this study, the authors investigate the impact of natural soiling on the performance loss of photovoltaic (PV) modules, specifically focusing on the concept of dust potency, which represents the soiling loss per unit area of dust mass and is influenced by dust composition and environmental conditions. Dust samples were collected from PV panels in Doha, Qatar, at various time intervals over a two-year period. The analysis reveals that the rate of dust accumulation and dust potency exhibit seasonal patterns influenced by environmental factors. Zeki Ahmed Darwish , Kamaruzzaman Sopian (2021) This project focuses on investigating the impact of different types of dust particles on the performance of photovoltaic (PV) modules. The accumulation of dust on PV modules is a well-known factor that contributes to power loss. However, the specific effects of different types of dust particles are often overlooked. This project aims to fill that gap by studying the influence of various dust particles, including carbon, iron oxide, manganese dioxide, calcium oxide, and natural dust, on the performance of PV modules. Umer Mehmood a, Fahad A. Al-Sulaiman a b, B.S. Yilbas (2017) This project focuses on the impact of dust accumulation and subsequent mud formation on solid surfaces, specifically the protective transparent covers of photovoltaic (PV) modules, in a humid environment. The study aims to provide a comprehensive analysis of environmental dust and dried mud and their effects on the properties of the protective covers, specifically polycarbonate wafers and glass. Julius Tanesab et.al (2017) The aim of this study is to examine the seasonal impact of dust on the degradation of photovoltaic (PV) modules deployed in two different climate regions: Perth, Western Australia, characterized by a temperate climate, and Nusa Tenggara Timur (NTT), Indonesia, characterized by a tropical climate. The results of the study demonstrate that the performance of PV modules varied with the seasons in both locations. 9 Department of EEE, FET-JU Study of Soiling Loss on Photovoltaic Modules with Artificially Deposited Dust of Different Gravimetric Densities and Compositions Collected From Different Countries. 2022-2023 Jim J. John, et.al (2016) In this study, the authors propose a cost-effective approach for evaluating the soiling loss on photovoltaic (PV) modules in a specific geographical location. Instead of relying on data collection from fielded PV systems, which can be time-consuming and expensive, the authors suggest collecting dust samples from various locations of interest, preferably from the module surface, and conducting soiling experiments in the laboratory. To enable controlled dust deposition, a low-cost artificial dust deposition technique is utilized. The study focuses on diverse soil samples collected from different climatic conditions and six geographic locations across India. Fani Mani, Subrahmanyam Pulipaka, Rajneesh Kumar (2016) This paper presents a model that quantifies the relationship between power output, incident irradiance, and the composition of soil particle sizes on soiled photovoltaic (PV) panels. The study utilizes soil samples collected from the Shekhawati region in India and determines the relative percentage of standard particle sizes through sieve analysis. Regression analysis is employed to establish a non-linear relationship between irradiance and power, taking into account the effect of particle size composition on the panel. Julius Tanesab et.al (2015) The contribution of dust to performance degradation of PV modules in a temperate climate zone. This research focuses on assessing the contribution of dust to the long-term performance degradation of photovoltaic (PV) modules that have been in operation for nearly eighteen years without cleaning at the Renewable Energy Outdoor Testing Area (ROTA) in Murdoch University, Perth, Australia. The study utilizes a solar module analyzer to evaluate the electrical performance of the PV modules and employs a combination of analytical techniques such as spectrophotometry, scanning electron microscopy, energy-dispersive spectroscopy, and X-ray diffraction to analyze the properties of the dust accumulated on the panels. Hassan Qasem, et.al (2014) In this study, the impact of dust on photovoltaic modules is investigated, focusing on its concentration and spectral transmittance. Samples of dust were collected in both raw form and as accumulated dust on exposed glass sheets at different tilt angles. The spectral transmittance of these samples was measured to assess the variation in transmittance across different positions (top, middle, and bottom) for various inclinations. 10 Department of EEE, FET-JU Study of Soiling Loss on Photovoltaic Modules with Artificially Deposited Dust of Different Gravimetric Densities and Compositions Collected From Different Countries. 2022-2023 Travis Sarver a, Ali Al-Qaraghuli b, Lawrence L. Kazmerski (2013) This literature review focuses on the impact of soiling, particularly dust and dustmoisture combinations, on the performance of solar energy systems. It provides a comprehensive overview of the soiling problems prevalent in solar-rich geographical locations worldwide. The review explores the historical context of studying soiling effects, understanding the mechanisms of dust accumulation, and evaluating the performance effects on both transmissive and reflective surfaces. It also discusses mitigation strategies such as surface coatings, cleaning methods, advanced materials, and system design considerations. By consolidating decades of research, this review emphasizes the significance of addressing soiling issues to enhance the efficiency and viability of solar energy systems. Patrick D. Burton, Bruce H. King (2013) This paper highlights the importance of consistent test methods for evaluating and predicting the performance loss of photovoltaic systems caused by soiling. The limitations of natural grime accumulation, including its time-consuming nature and location-specificity, are acknowledged, emphasizing the need for reproducible results across different geographic regions. To address this challenge, the authors have presented a novel technique involving artificial soiling using NIST-traceable components through an aerosol spray method. Kathy Brown; Tim Narum; Naiyong Jing This paper focuses on the accumulation of soil on photovoltaic modules and its negative impact on power output. The authors aim to enhance the understanding and modeling of this issue by developing soiling test methods that replicate specific environmental conditions. They highlight the numerous factors that influence accurate measurements and the extrapolation of laboratory data to real-world performance. Adrianne Kimber, SunPower Corporation (2007) The findings of this research contribute to improving the understanding of the effects of soiling on PV systems, enabling better decision-making regarding cleaning schedules and maintenance strategies. By quantifying the energy losses associated with soiling and assessing its economic implications, this study provides valuable insights for solar energy projects in arid regions, aiding in maximizing system performance and optimizing revenue generation. 11 Department of EEE, FET-JU Study of Soiling Loss on Photovoltaic Modules with Artificially Deposited Dust of Different Gravimetric Densities and Compositions Collected From Different Countries. 2022-2023 CHAPTER 3 OBJECTIVES AND METHODOLOGY 3.1 OBJECTIVES The main objectives of this research paper are as follows: i).To collect soil samples from four different countries (Bhutan, Bangladesh, Nepal, and India) and analyze their composition and characteristics. ii).To assess the impact of dust deposition on the performance of PV modules. iii).To contribute to a deeper understanding of the soiling phenomenon and its implications for solar energy systems. 3.2 METHODOLOGY 3.2.1 EXISTING METHODOLOGY The existing research project proposes a novel method to quantify the effects of soiling on PV modules, particularly in the Indian context. Their analysis procedure, illustrated in below flowchart involves directly collecting dust samples from the surface of operational PV modules. This approach is crucial because the particle size distribution and composition of dust on PV module surfaces differ from those obtained from ground or airborne sources. Figure 3.1 Existing Methodology 12 Department of EEE, FET-JU Study of Soiling Loss on Photovoltaic Modules with Artificially Deposited Dust of Different Gravimetric Densities and Compositions Collected From Different Countries. 2022-2023 In their study, the researchers performed optical and electrical characterization of dust samples obtained from two significant locations in India: Jodhpur and Mumbai. Jodhpur, situated in the state of Rajasthan, boasts the highest installed PV power generation capacity in India due to its abundant solar insolation. Mumbai, on the other hand, represents a typical urban city in Maharashtra and demonstrates considerable potential for rooftop PV installations. Although they collected a limited quantity of dust samples from Gurgaon, Hanle, Agra, and Pondicherry, their focus primarily lay on optical characterization with a gravimetric density of 1.8 g/m2. To gain comprehensive insights into the impact of dust on PV module performance, the researchers conducted an examination of particle size distribution and mineral compositions using a subset of the collected dust samples. By employing this methodology, their objective is to contribute valuable findings on the effects of dust specifically on PV modules in diverse geographical regions within India. 3.2.2 PROPOSED METHODOLOGY Our methodology builds upon the existing research, aiming to provide a more costeffective approach. Like the previous study, we artificially applied soil samples and measured the resulting loss on each sample. However, we introduced an innovative step to assess the moisture content of the soil. 13 Department of EEE, FET-JU Study of Soiling Loss on Photovoltaic Modules with Artificially Deposited Dust of Different Gravimetric Densities and Compositions Collected From Different Countries. 2022-2023 Figure 3.2 Proposed Methodology To conduct our experiment, we followed the following steps: Step 1: We began by recording the initial ratings of the solar panel, which included a maximum voltage of 21V, maximum current of 0.62A, panel inclination set at 45 degrees, and a daytime temperature of 30°C. Step 2: We collected soil samples from four different regions: Bangladesh, Nepal, India, and Bhutan. Step 3: The maximum weight allowed for each soil sample was set at 67.2g. Step 4: We evenly spread the soil samples onto the surface of the solar panel before initiating the heating process. Step 5: At this point, we recorded the voltage and current ratings of the solar panel for each of the four soil regions. Step 6: Afterward, we carefully collected the soil samples from the solar panel. Step 7: Each soil sample was placed in a crucible container for further analysis. Step 8: The crucible containers, with the soil samples inside, were then positioned within a muffle furnace. Step 9: The temperature inside the muffle furnace was set to 150°C and maintained for a duration of 24 hours. Step 10: After the allotted time, we removed the crucible containers from the muffle furnace. 14 Department of EEE, FET-JU Study of Soiling Loss on Photovoltaic Modules with Artificially Deposited Dust of Different Gravimetric Densities and Compositions Collected From Different Countries. 2022-2023 Step 11: The weight of each soil sample was measured again to assess any changes that occurred during the 24-hour heating process. Step 12: By comparing the weights of the soil samples before and after exposure to the muffle furnace, we determined the amount of moisture that was reduced from each soil sample. Step 13: We recorded the specific reduction in soil moisture for each of the different soil regions. Step 14: Based on our findings, we analyzed the data to identify the optimal country for solar panel installation, considering the impact of soil moisture on panel performance. 3.3 RESOURCES 3.3.1 SOLAR PANEL Solar panels, also known as photovoltaic panels or PV panels, are remarkable devices that harness the power of sunlight and convert it into usable electricity. These panels consist of interconnected solar cells made primarily of silicon, which possess the remarkable ability to generate an electric current when exposed to sunlight. This conversion of sunlight into electricity is made possible through the photovoltaic effect, a phenomenon discovered in the mid-19th century. Over the years, advancements in solar panel technology have resulted in increased efficiency and affordability. Solar panels offer numerous benefits, such as providing a clean and renewable source of energy, reducing reliance on fossil fuels, and offering long-term cost savings on electricity bills. They also contribute to environmental sustainability by reducing carbon emissions and promoting energy independence. With their durability and minimal maintenance requirements, solar panels have become a popular choice for residential, commercial, and even remote applications. The availability of solar panels through specialized retailers, installers, and online platforms has made it easier for individuals and businesses to embrace this sustainable energy solution and make a positive impact on the environment. 15 Department of EEE, FET-JU Study of Soiling Loss on Photovoltaic Modules with Artificially Deposited Dust of Different Gravimetric Densities and Compositions Collected From Different Countries. 2022-2023 Figure 3.3 Solar panel with specifications 10W, 21V, and 0.65A A solar panel with specifications 10W, 21V, and 0.65A means that the panel can generate a maximum power of 10 watts when exposed to sunlight, at a voltage of 21 volts and a current of 0.65 amps. This panel can be used to charge batteries or power electronic devices that operate on DC voltage. However, it’s important to note that the actual power output may vary depending on the intensity of sunlight and other environmental factors. It’s also important to use the appropriate charge controller and wiring to ensure safe and efficient operation of the panel. 3.3.1.1 HOW DO SOLAR PANELS WORK? Solar panels collect clean renewable energy in the form of sunlight and convert that light into electricity which can then be used to provide power for electrical loads. Solar panels are comprised of several individual solar cells which are themselves composed of layers of silicon, phosphorous (which provides the negative charge), and boron (which provides the positive charge). Solar panels absorb the photons and in doing so initiate an electric current. The resulting energy generated from photons striking the surface of the solar panel allows electrons to be knocked out of their atomic orbits and released into the electric field generated by the solar cells which then pull these free electrons into a directional current. This entire 16 Department of EEE, FET-JU Study of Soiling Loss on Photovoltaic Modules with Artificially Deposited Dust of Different Gravimetric Densities and Compositions Collected From Different Countries. 2022-2023 process is known as the Photovoltaic Effect. An average home has more than enough roof area for the necessary number of solar panels to produce enough solar electricity to supply all of its power needs excess electricity generated goes onto the main power grid, paying off in electricity use at night. Figure 3.4 Solar panel construction and working principle In a well-balanced grid-connected configuration, a solar array generates power during the day that is then used in the home at night. Net metering programs allow solar generator owners to get paid if their system produces more power than what is needed in the home. In off-grid solar applications, a battery bank, charge controller, and in most cases, an inverter are necessary components. The solar array sends direct current (DC) electricity through the charge controller to the battery bank. The power is then drawn from the battery bank to the inverter, which converts the DC current into alternating current (AC) that can be used for non-DC appliances. Assisted by an inverter, solar panel arrays can be sized to meet the most demanding electrical load requirements. The AC current can be used to power loads in homes or commercial buildings, recreational vehicles and boats, remote cabins, cottages, or homes, remote traffic controls, telecommunications equipment, oil and gas flow monitoring, RTU, SCADA, and much more. 3.3.2 MULTIMETER A multimeter is a device used to measure multiple parameters of an electric circuit like voltage, current, and resistance. The device is made up of a digital or analog meter, batteries, resistors, and other circuitry, which ensure the measurement of several electrical quantities with very high accuracy and speed. A multimeter is used to troubleshoot electrical problems on 17 Department of EEE, FET-JU Study of Soiling Loss on Photovoltaic Modules with Artificially Deposited Dust of Different Gravimetric Densities and Compositions Collected From Different Countries. 2022-2023 motors, circuits, power supplies, and switches. It is one of the most common tools used by technicians, students, and engineers across the globe. Hence, familiarizing the components of a multimeter and how to set it for various measurements has become inevitable while dealing with an electrical circuit. In this article, we cover everything you need to know about how to use. 3.3.2.1 USES OF MULTIMETER A multimeter is the most common tool used by technicians to troubleshoot electrical issues. A few examples of use cases are: • To test a questionable battery, connecting the multimeter leads and measuring the DC voltage across, is a quick and efficient way to decide whether it is dead, good, or somewhere between. • While assembling different parts of a project or product, it is common to work with a bundle of wires of the same color, in which case a multimeter can be used to test the resistance of each one which helps to distinguish one from the other. • When in doubt regarding which pin is ‘live’ while checking an AC outlet, a multimeter can be used to determine the voltage coming out of the point and thereby check if it is live. • While working on electronic boards, it is common to worry if a chip has overheated or a capacitor is faulty or not, and a multimeter can be used to check whether the temperature is within limits. • Coaxial cables can be checked for their continuity using a multimeter. Figure 3.5 A digital multimeter with its probes and front panel 18 Department of EEE, FET-JU Study of Soiling Loss on Photovoltaic Modules with Artificially Deposited Dust of Different Gravimetric Densities and Compositions Collected From Different Countries. 2022-2023 3.3.2.2 MULTIMETER COMPONENTS 1. Selection knob (A): The knob comes with an arrow pointer at its end to choose the parameter being measured (like the voltage, current, and resistance). 2. Display panel (B): The display is a liquid crystal display (LCD), which can show up to four digits under normal circumstances, and also has the provision to display a negative sign. 3. Ports (C): There are three main ports on the front panel of a multimeter: a. COM symbolizes COMMON and is usually used to connect the ground or negative part of the circuit. b. VΩmA enables the measurement of voltage, current (up to 200mA), and resistance. c. 10A is the special port used to measure large currents (typically greater than 200mA). 4. Probes (D): Typically, a multimeter unit comes with two insulated probes (a red probe and a black probe) to establish an electrical connection between the device under test (DUT) and the multimeter. The plug of the red probe is connected to the VΩmA port, and that of the black probe is connected to the COM port, while their leads are connected to the positive and negative terminals of the device under test (DUT). Other than the color, there is no difference between the red and black probes. 3.3.3 MUFLE FURNACE A muffle furnace is a heating device that meets the precise temperature control and temperature uniformity requirements of laboratory work. It is a standard piece of equipment in many labs, used for a wide range of applications such as aching or heat treatment of materials. Muffle furnaces are also known as chamber furnaces or box furnaces. 19 Department of EEE, FET-JU Study of Soiling Loss on Photovoltaic Modules with Artificially Deposited Dust of Different Gravimetric Densities and Compositions Collected From Different Countries. 2022-2023 Figure 3.6 Muffle furnace -1100° 3.3.3.1 TEMPERATURE RANGE OF A MUFFLE FURNACE Muffle furnaces are available with a range of maximum temperatures. The maximum temperature is dependent on the type of heating elements used in the construction. The most common have metallic wire heating elements with a maximum temperature in the range of 1000°C to 1200°C. Muffle furnaces with silicon carbide heating elements can achieve 1600°C and with molybdenum Di silicide heating elements can achieve 1800°C. 3.3.3.2 APPLICATION OF MUFFLE FURNACE Muffle furnaces can be used for a wide range of applications that include aching, heat treatment of materials, annealing, calcination, and loss on ignition analysis, thermo gravimetric analysis, quenching, and sintering. 3.3.3.3 HOW LONG DOES A MUFFLE FURNACE REQUIRE REACHING MAXIMUM TEMPERATURE? The time required for a muffle furnace to reach maximum temperature is dependent on a number of factors including the size of the furnace, the maximum power available, and the material used in the construction of the furnace. A small laboratory scale furnace with low thermal mass insulation can reach maximum temperature in as little as 20 minutes, whereas a larger scale furnace using dense refractory materials may take several hours to reach maximum temperature. 20 Department of EEE, FET-JU Study of Soiling Loss on Photovoltaic Modules with Artificially Deposited Dust of Different Gravimetric Densities and Compositions Collected From Different Countries. 2022-2023 3.3.4 WEIGHTING SCALE Shimadzu 220g (Top Loading Balance, BL220H) is an amazing product for regular usage. This weighing machine has been designed to accurately indicate you with the Figure 3.7 Shimadzu BL220H measurements. The compact design of this digital Weighing scale makes it easy to fit in any corner. With LCD display this weighing scale shows bright readings. It can easily measure mass up to 220 g. This product is perfect for regular usage. The weighing platform size for this product is 100x100 mm. About Shimadzu BL220H • Display: 1mg/0.001g • Capacity: 220g • Pan Size: 100 x 100 • Calibration: External • Type: Top Pan 3.3.5 HIGH TEMPRATUR QUARTZ CRUCIBLE A High Temperature Quartz Crucible is a container made of high-purity quartz glass that can withstand extreme temperatures without melting or deforming. These crucibles are commonly used in high-temperature applications such as materials research, chemical analysis, and crystal growth. 21 Department of EEE, FET-JU Study of Soiling Loss on Photovoltaic Modules with Artificially Deposited Dust of Different Gravimetric Densities and Compositions Collected From Different Countries. 2022-2023 The high-purity quartz glass used to make these crucibles is extremely resistant to thermal shock and chemical attack, making it ideal for use in harsh laboratory environments. The melting point of quartz glass is over 1700 degrees Celsius, which means it can withstand temperatures that would melt most other types of glass. High-temperature quartz crucibles are often used to melt and fuse materials at high temperatures, to grow single crystals from a melt, and to perform high-temperature chemical reactions. They are available in a range of sizes and shapes, including cylindrical, conical, and spherical, to suit different experimental requirements. Figure 3.8 High Temperature Quartz Crucible 3.3.5.1 MATERIAL High temperature quartz crucibles are made of high purity fused silica, which is a type of quartz glass that is almost completely free of impurities. This gives the crucibles excellent thermal stability and resistance to chemical attack. Properties: High temperature quartz crucibles have a number of properties that make them ideal for use in high-temperature applications. They have a low coefficient of thermal expansion, which means they can withstand rapid temperature changes without cracking or breaking. They are also transparent to a wide range of wavelengths, which makes them useful for optical experiments. Additionally, they have a high thermal conductivity, which means they can distribute heat evenly across their surface. 22 Department of EEE, FET-JU Study of Soiling Loss on Photovoltaic Modules with Artificially Deposited Dust of Different Gravimetric Densities and Compositions Collected From Different Countries. 2022-2023 3.3.5.2 USES High temperature quartz crucibles are used in a variety of applications, including: 1. Materials research: These crucibles are used to melt and fuse materials at high temperatures, which can help researchers study their properties and behavior. 2. Chemical analysis: High temperature quartz crucibles are used in high-temperature chemical reactions and to hold samples for analysis with techniques such as X-ray diffraction. 3. Crystal growth: These crucibles are used to grow single crystals from a melt. The high purity of the quartz glass helps ensure the crystals are of high quality. 4. Sizes and shapes: High temperature quartz crucibles are available in a range of sizes and shapes to suit different experimental requirements. Common shapes include cylindrical, conical, and spherical, and sizes can range from a few millimeters to several centimeters in diameter. 5. Care and maintenance: To ensure the longevity and reliability of high temperature quartz crucibles, it’s important to handle and clean them carefully. They should be handled with gloves to avoid contamination from skin oils, and cleaned with mild soap and water or specialized cleaning solutions designed for use with quartz glass. Scratches and chips should be avoided, as they can weaken the crucible and increase the risk of breakage. 3.3.6 BEAKERS (80 ML) An 80 ml beaker is a laboratory glassware container used for holding, mixing, and pouring small volumes of liquid reagents. It is typically made of borosilicate glass, which is a type of glass that is resistant to thermal shock and chemical attack, and has a high resistance to temperature changes. The 80 ml beaker is a relatively small beaker, with a capacity of 80 milliliters, or about 2.7 fluid ounces. It is often used in laboratory settings where small volumes of liquids are needed, such as in experiments that require precise measurements or small-scale reactions. The beaker has a cylindrical shape with a flat bottom and a spout for easy pouring. It is graduated with volume markings on the side, typically in 10 ml increments, to allow for accurate measurement of liquid volumes. The beaker can be used for a variety of laboratory applications, such as preparing solutions, mixing chemicals, and heating small samples. 23 Department of EEE, FET-JU Study of Soiling Loss on Photovoltaic Modules with Artificially Deposited Dust of Different Gravimetric Densities and Compositions Collected From Different Countries. 2022-2023 Overall, the 80 ml beaker is a versatile and commonly used piece of laboratory glassware that is suitable for a range of applications. Figure 3.9 ML Beaker 3.3.6.1 MATERIAL 80 ml beakers are typically made of borosilicate glass, which is a type of glass that is resistant to thermal shock and chemical attack. This makes it ideal for use in laboratory settings, where chemicals and solutions are frequently heated or cooled and exposed to a variety of chemical compounds. 3.3.6.2 USES 80 ml beakers are commonly used in laboratory settings for a variety of purposes. Some common uses include: • Preparing and mixing solutions: Beakers can be used to measure out and mix different chemicals and solutions. • Heating small samples: Beakers can be placed on a hot plate or heated over a Bunsen burner to heat small samples. • General storage: Beakers can be used to store small amounts of chemicals or solutions. • Conducting small-scale reactions: Beakers can be used to perform small-scale chemical reactions, such as acid-base titrations or precipitation reactions. • Design: 80 ml beakers typically have a cylindrical shape with a flat bottom and a pouring spout. They may also have a small lip or handle to make them easier to hold and pour. The beakers are usually graduated with volume markings on the side to allow for accurate measurement of liquid volumes. • Care and Maintenance: To ensure the longevity and accuracy of 80 ml beakers, it is important to handle and clean them carefully. They should be cleaned with mild soap 24 Department of EEE, FET-JU Study of Soiling Loss on Photovoltaic Modules with Artificially Deposited Dust of Different Gravimetric Densities and Compositions Collected From Different Countries. 2022-2023 and water or specialized cleaning solutions designed for use with laboratory glassware. Any visible cracks or chips should be avoided, as they can weaken the beaker and increase the risk of breakage. Additionally, beakers should not be heated or cooled too rapidly, as this can cause thermal shock and lead to cracking or breakage. 3.3.7 LAB SPOON A lab spoon is a type of laboratory tool used for transferring small amounts of solid or liquid samples. It is typically made of materials such as stainless steel, plastic, or PTFE (poly tetrafluoro ethylene), which are chemically inert and do not react with the substances being transferred. Figure 3.10 Lab spoons Lab spoons come in various shapes and sizes, depending on their specific application. Some common types of lab spoons include: 1. Micro spoons: These are tiny spoons with a volume of less than 1 milliliter. They are used for transferring small amounts of solid or liquid samples. 2. Spatulas: These have a flat, rectangular or triangular blade and are used for scraping, stirring, and transferring powders and other solid materials. 3. Weighing scoops: These have a scoop-shaped bowl and are used for accurately measuring and transferring small quantities of powders and other solid materials. 4. Medicine droppers: These have a glass or plastic tube with a rubber bulb at one end and are used for transferring small volumes of liquids. Lab spoons are commonly used in laboratory settings where precision and accuracy are important, such as in analytical chemistry, microbiology, and molecular biology. They can also be used in food science, pharmaceuticals, and other industries where small samples need to be handled and transferred. To ensure accurate and consistent results, lab spoons should be handled carefully and cleaned thoroughly after each use. 25 Department of EEE, FET-JU Study of Soiling Loss on Photovoltaic Modules with Artificially Deposited Dust of Different Gravimetric Densities and Compositions Collected From Different Countries. 2022-2023 3.3.8 SOIL REGIONS i). Bangladesh soil location: Bagerhat, Bangladesh Bagerhat is a district located in the southwestern part of Bangladesh. It is situated in the Khulna Division and bordered by the districts of Khulna, Satkhira, and Gopalganj. The district has a total area of 3,959 square kilometers and is primarily a flat, low-lying region with many rivers and canals. The soil in Bagerhat is mostly alluvial soil, which is fertile and suitable for agricultural cultivation. The district is known for its rice cultivation and shrimp farming industries. ii). Bhutan soil location: Thimphu, Bhutan Garden Thimphu is the capital city of Bhutan, located in the western part of the country. The soil in Thimphu and Bhutan, in general, varies depending on the location and altitude. In the lower altitude areas, the soil is generally alluvial and fertile, while in higher altitude areas, the soil is rocky and less fertile. In Thimphu, the soil is primarily composed of clay and loam, with varying levels of organic matter. The soil is suitable for growing a variety of crops, including vegetables, fruits, and grains. Thimphu is also known for its beautiful gardens and parks, which are maintained by the government and private organizations. The most popular garden in Thimphu is the Centenary Farmers’ Market, which is open seven days a week and sells a wide range of local produce, including fresh fruits, vegetables, and flowers. The Royal Botanical Garden in Serbithang is another popular attraction, featuring a variety of native and exotic plant species. Overall, the soil in Thimphu and Bhutan provides a fertile base for agriculture and gardening. iii). Nepal soil location: Kathmandu, Nepal Kathmandu is the capital city of Nepal, located in the central part of the country. The soil in Kathmandu and Nepal, in general, varies depending on the location and altitude. The country has a diverse topography ranging from the high Himalayas in the north to the flatlands in the south, which result in a wide range of soil types. In the Kathmandu Valley, the soil is primarily composed of clay, silt, and sand, with varying levels of organic matter. The soil is generally fertile and suitable for agriculture, although it is also prone to erosion and landslides.The most common crops grown in Kathmandu and the surrounding areas include rice, maize, wheat, vegetables, and fruits. The city is also 26 Department of EEE, FET-JU Study of Soiling Loss on Photovoltaic Modules with Artificially Deposited Dust of Different Gravimetric Densities and Compositions Collected From Different Countries. 2022-2023 known for its beautiful gardens and parks, which are maintained by the government and private organizations. The Garden of Dreams, located in the heart of Kathmandu, is a popular attraction for both tourists and locals. It features a variety of exotic plants, flowers, and trees, as well as fountains, pavilions, and ponds. Overall, the soil in Kathmandu and Nepal provides a fertile base for agriculture and gardening, and the region is known for its diverse plant and animal life. iii). India soil location: Jain University, Bangalore, India Jain University is a private university located in Bengaluru, the capital city of the Indian state of Karnataka. The soil in the region is primarily composed of red laterite soil, which is rich in iron and aluminum but low in nitrogen and phosphorus. Laterite soil is commonly found in tropical regions and is formed by the weathering of rocks and minerals over long periods of time. The soil is well-drained and can support a variety of crops, including vegetables, fruits, and grains. However, it requires careful management and fertilization to maintain its fertility, as it is low in essential nutrients such as nitrogen and phosphorus. In the Bengaluru region, agriculture is an important industry, and the most commonly grown crops include rice, maize, millet, and sugarcane. The region is also known for its horticulture, with a variety of fruits and vegetables grown throughout the year. Overall, the soil in the Bengaluru region, including the soil at Jain University, is suitable for agriculture and provides a fertile base for plant growth. However, careful management and fertilization are necessary to maintain soil fertility and crop yields. 3.4 WORKING PROCESS In general, the performance of a solar panel is affected by several factors, including the angle of the panel relative to the sun, the temperature, and the amount of sunlight it receives. Ideally, a solar panel should be positioned at an angle that maximizes its exposure to the sun's rays throughout the day. The optimal angle will depend on your location, the time of year, and other factors. The maximum voltage and current of your solar panel are also important factors to consider. The maximum voltage of 21V indicates the highest voltage the panel can generate, 27 Department of EEE, FET-JU Study of Soiling Loss on Photovoltaic Modules with Artificially Deposited Dust of Different Gravimetric Densities and Compositions Collected From Different Countries. 2022-2023 while the maximum current of 0.62A indicates the highest amount of current it can output. These specifications will determine the amount of power that the solar panel can generate, which can be calculated by multiplying the voltage and current (P = V x I). Figure 3.11 Working Process The temperature can also affect the performance of a solar panel. Generally, as the temperature increases, the efficiency of the solar panel decreases, causing it to generate less power. It's important to note that the temperature of the solar panel itself can be higher than the ambient temperature, especially if it's in direct sunlight. To get the most out of your solar panel, you may want to consider positioning it at an angle that maximizes its exposure to the sun's rays and taking steps to minimize the impact of high temperatures. This might include using a heat sink or fan to dissipate heat or positioning the solar panel in a location that's shaded during the hottest parts of the day. Figure 3.12 Solar rating before test 28 Department of EEE, FET-JU Study of Soiling Loss on Photovoltaic Modules with Artificially Deposited Dust of Different Gravimetric Densities and Compositions Collected From Different Countries. 2022-2023 Figure 3.13 VI curve under normal condition 3.4.1 MEASUREMENT OF SOIL SAMPLE To proceed with the given steps, you would need to follow these guidelines: • Collect soil samples from Bangladesh, Nepal, India, and Bhutan. • Measure the 4 types of soil samples using appropriate measuring tools. • Ensure that the weight of each country's soil sample does not exceed 67.2g. It's important to note that the measuring tools used should be calibrated and accurate to ensure precise measurements. Additionally, to ensure that the samples are representative of the soil from each country, it is recommended to collect multiple samples from different locations within each country and then mix them before measuring. Once you have measured each soil sample and ensured that the maximum weight of each country's sample is 67.2g, you can proceed with any further analysis or testing required. 29 Department of EEE, FET-JU Study of Soiling Loss on Photovoltaic Modules with Artificially Deposited Dust of Different Gravimetric Densities and Compositions Collected From Different Countries. 2022-2023 Figure 3.14 measuring the amount of soils 3.4.2 POUR THE SOIL ON THE SURFACE OF SOLAR PANEL BEFOR HEATING Pouring soil on the surface of a solar panel is not recommended as it can damage the panel and affect its performance. Soil particles can scratch or abrade the surface of the solar panel, which can reduce its efficiency and lifespan. Additionally, soil can also block the sunlight from reaching the solar cells, which can further decrease the panel's power output. If you need to test the effect of soil on solar panel performance, there are other ways to do so without directly pouring soil on the panel. For example, you can place the solar panel in a location where it is exposed to soil and dust, or you can use artificial soil and dust simulators to replicate the conditions. You can then measure the panel's performance over time and compare it to its performance in a clean environment to determine the impact of soil on the panel. 30 Department of EEE, FET-JU Study of Soiling Loss on Photovoltaic Modules with Artificially Deposited Dust of Different Gravimetric Densities and Compositions Collected From Different Countries. 2022-2023 To take the ratings of voltage and current from all four regions, we followed these steps: • Place the solar panel in a location where it receives sunlight with temperature of 30°C for all four regions (Bangladesh, Nepal, India, and Bhutan). • Connect the solar panel to a voltage and current measuring device, such as a multimeter or data logger. • Record the voltage and current readings from the device. • Repeat the measurement process multiple times to get an average rating for each region. Once we have taken the voltage and current ratings from all four regions, we can analyze the data to determine if there are any significant differences in the solar panel's performance based on the location. This information can be used to optimize the placement and orientation of solar panels in each region for maximum efficiency. Figure 3.15 Effect of Bhutan soil on solar rating (V x I) Figure 3.16 VI curve for Bhutan soil sample 31 Department of EEE, FET-JU Study of Soiling Loss on Photovoltaic Modules with Artificially Deposited Dust of Different Gravimetric Densities and Compositions Collected From Different Countries. 2022-2023 In the case of Bhutan, the maximum voltage observed is 18.3V, while the maximum current reaches 0.31A. The VI curve is shown above. Figure 3.17 Effect of Indian soil on solar rating (V x I) Figure 3.18 I x V (V x I) curve for Indian soil sample India, as another subject in the study, exhibits distinct electrical characteristics. In the case of India’s soil sample, the highest recorded voltage stands at 18.1V. Similarly, the maximum current observed in India reaches 0.41A. The provided VI curve graph visually illustrates the relationship between voltage and current 32 Department of EEE, FET-JU Study of Soiling Loss on Photovoltaic Modules with Artificially Deposited Dust of Different Gravimetric Densities and Compositions Collected From Different Countries. 2022-2023 Figure 3.19 Effect of Bangladesh soil on solar rating (V x I Figure 3.20 VI curve for Bangladesh soil sample Within Bangladesh, the highest recorded voltage stands at 19.8V and the maximum current measured in Bangladesh’s soil sample reached 0.33A, 33 Department of EEE, FET-JU Study of Soiling Loss on Photovoltaic Modules with Artificially Deposited Dust of Different Gravimetric Densities and Compositions Collected From Different Countries. 2022-2023 Figure 3.21 Effect of Nepal soil on solar rating (V x I) Figure 3.22 I x V (V x I) curve for Nepal soil sample Nepal's soil sample reveals a peak voltage of 19.7V, accompanied by a maximum current of 0.27A. The VI curve graph visually illustrates the relationship between voltage and current, offering a concise representation of the findings in the test conducted. 3.4.3 FINDING AMOUNT OF MOISTURE IN THE SOIL SAMPLE During the experiment, soil samples were collected again for scientific analysis, with the purpose of studying their composition, properties, and moisture content. The Crucible containers were used as vessels to hold the soil samples throughout the analysis process. The process was carried out into two parts. 34 Department of EEE, FET-JU Study of Soiling Loss on Photovoltaic Modules with Artificially Deposited Dust of Different Gravimetric Densities and Compositions Collected From Different Countries. 2022-2023 First Part: Soil Sample Preparation and Heating • Label each Crucible container with a unique identifier to track the soil samples accurately. • Weigh each Crucible container empty and record the weight as the baseline measurement. • Add a measured amount of soil from each sample location to its corresponding labeled Crucible container. • Weigh each Crucible container with the soil sample and record the weight. • Transfer the Crucible containers to a laboratory for further analysis, following safety protocols. • Place the Crucible containers with the soil samples into a muffle furnace and set the temperature to 150°C. • Allow the Crucible containers to heat at 150°C for 24 hours, ensuring safety and proper handling. • After 24 hours, turn off the muffle furnace and let it cool down to room temperature. • Weigh each Crucible container with the soil sample again to determine the weight of the residue remaining after heating. Figure 3.23 Muffle furnaces at 150°C for 24 hours Second Part: Post-Heating Analysis and Conclusion • Perform further analysis on the residues to determine their composition and properties. • Remove the Crucible containers with the soil samples from the muffle furnace. • Carefully handle the Crucible containers and extract the soil samples from each container. • Transfer the soil samples to clean and dry containers for further analysis, following safety protocols. 35 Department of EEE, FET-JU Study of Soiling Loss on Photovoltaic Modules with Artificially Deposited Dust of Different Gravimetric Densities and Compositions Collected From Different Countries. • 2022-2023 Weigh each Crucible container with the soil sample again to determine the weight of the residue left after heating. • Calculate the difference in weight between the soil samples before and after heating to determine the amount of moisture removed. • Record the amount of moisture removed from each soil sample and compare the results for variations. • Write down the results of the analysis in a clear and organized manner, including relevant observations and notes. Figure 3.24 calculate the weight after muffle furnace. The analysis results, including any relevant observations or notes, are carefully documented, providing valuable insights and conclusions about the composition, properties, and moisture content of the soil samples. 36 Department of EEE, FET-JU Study of Soiling Loss on Photovoltaic Modules with Artificially Deposited Dust of Different Gravimetric Densities and Compositions Collected From Different Countries. 2022-2023 CHAPTER 4 RESULTS AND DISCUSSION Number Country Voltage (V) Current (A) - - 1 Bhutan Maximum voltage 21.0 18.3 Maximum current 0.65 0.31 2 India 18.1 0.41 3 Bangladesh 19.8 0.33 4 Nepal 19.7 0.27 Table 4.1 PV module performance data The PV module performance data in Table 1 provides information on the voltage and current outputs of the PV modules from each country. The maximum voltage and current values observed during the measurements were 21.0 V and 0.65 A, respectively. Bhutan recorded a voltage of 18.3 V and a current of 0.31 A, while India had a voltage of 18.1 V and a current of 0.41 A. Bangladesh showed a voltage of 19.8 V and a current of 0.33 A, and Nepal exhibited a voltage of 19.7 V and a current of 0.27 A. In this study, the PV module performance data from four different countries (Bhutan, India, Bangladesh, and Nepal) were analysed to assess the impact of dust deposition on power generation. The maximum voltage and current values were recorded as 21.0 V and 0.65 A, respectively. After artificially depositing soil samples on the PV modules, the voltage and current outputs were measured for each country. The power loss was calculated by subtracting the power generated in each country from the maximum power. The results showed that Bhutan experienced a power loss of 7.977 W (58.47% loss), India had a power loss of 6.229 W (45.60% loss), Bangladesh had a power loss of 7.116 W (52.12% loss), and Nepal had a power loss of 8.331 W (61.03% loss). These findings highlight the significant impact of dust deposition on PV module performance, emphasizing the need for effective cleaning strategies to mitigate efficiency losses and maximize energy output. 37 Department of EEE, FET-JU Study of Soiling Loss on Photovoltaic Modules with Artificially Deposited Dust of Different Gravimetric Densities and Compositions Collected From Different Countries. 2022-2023 Figure 4.1 VI Curve in bar graph Number Country Final Weight Bhutan Soil weight with moisture 67.2g 64g Moisture contains in the soil 3.2g 1 2 India 67.2g 66.6g 0.6g 3 Bangladesh 67.2g 66.28g 0.92g 4 Nepal 67.2g 63.9 3.3g Table 4.2 Weight of soil samples before and after removing moisture The table presents the weight of the soil samples before and after removing moisture through a heating process in a muffle furnace. The initial weight of the soil samples for all four countries was 67.2g. After subjecting the samples to the heating process for 24 hours, the weights of the soil samples after removing moisture were recorded. For Bhutan, the weight of the soil sample reduced to 3.2g after the moisture was eliminated through heating. Similarly, for Nepal, the weight decreased to 3.3g. In the case of India, the weight reduced to 0.6g, while Bangladesh recorded a weight of 0.92g after moisture removal. By heating the soil samples in a muffle furnace, the moisture content was effectively eliminated, allowing for a more accurate assessment of the dry weight of the soil. This information is 38 Department of EEE, FET-JU Study of Soiling Loss on Photovoltaic Modules with Artificially Deposited Dust of Different Gravimetric Densities and Compositions Collected From Different Countries. 2022-2023 valuable for understanding the soil characteristics and composition in each country, which can further contribute to analysing the impact of dust deposition on PV module performance. Nepal, which exhibited the highest power loss among the countries studied, also had a relatively high amount of moisture in the soil sample after removing it through the heating process. The soil sample from Nepal retained 3.3g of moisture, indicating a higher level of water content. This correlation suggests that the presence of moisture in the soil can contribute to increased power loss in PV module performance. Moisture on the surface of the PV modules can further enhance the adhesion of dust particles, leading to more severe soiling and efficiency losses. On the other hand, India, which had the lowest power loss among the countries, also recorded the lowest amount of moisture content in the soil sample after the heating process. The soil sample from India retained only 0.6g of moisture, indicating a lower level of water content. This correlation implies that a lower moisture content in the soil can contribute to reduced power loss in PV module performance. With less moisture present, the adherence of dust particles to the PV module surfaces may be minimized, leading to less severe soiling and efficiency losses. 39 Department of EEE, FET-JU Study of Soiling Loss on Photovoltaic Modules with Artificially Deposited Dust of Different Gravimetric Densities and Compositions Collected From Different Countries. 2022-2023 CONCLUSION This study reveals significant variations in power loss among Nepal, India, Bhutan, and Bangladesh, which can be attributed to differences in soil moisture content and other regional factors. Nepal, with the highest soil moisture content of 3.3g, experienced the highest power loss (61.03%). This can be attributed to the increased adhesion and accumulation of dust particles on solar panels due to the cohesive properties of moist soil. In contrast, India, with the lowest soil moisture content of 0.6g, exhibited the lowest power loss (45.60%), indicating reduced dust adhesion and easier cleaning. Bhutan and Bangladesh, with their respective soil moisture contents, also demonstrate varying power loss percentages. Bhutan's power loss (58.47%) falls between Nepal and India, suggesting an intermediate level of soiling influenced by its soil moisture content. Similarly, Bangladesh, with a soil moisture content of an intermediate value, experiences a power loss percentage of 52.12%. These findings highlight the importance of considering regional factors such as soil moisture content when assessing and optimizing the performance of solar energy systems. By understanding the influence of moisture and implementing appropriate maintenance and cleaning strategies, solar panel efficiency can be maximized, and power loss minimized across different geographical locations. 40 Department of EEE, FET-JU Study of Soiling Loss on Photovoltaic Modules with Artificially Deposited Dust of Different Gravimetric Densities and Compositions Collected From Different Countries. 2022-2023 FUTURE SCOPE Some of the future scopes of this project could include: 1. Expansion of Dust Sample Collection: The current study collected dust samples from four countries. However, there are numerous regions worldwide with varying environmental conditions and dust compositions. Future research can involve expanding the collection of dust samples from additional countries and regions, providing a more comprehensive understanding of the global variations in soiling loss. 2. Investigation of Dust Composition: The project focused on studying the impact of dust from different countries. Further research can delve deeper into the composition and characteristics of the collected dust samples. Analyzing the chemical and physical properties of the dust, such as particle size distribution, elemental composition, and organic content, can provide insights into their adhesion mechanisms and soiling behavior. 3. Influence of Dust Properties: This project examined the impact of dust gravimetric densities and compositions on PV module performance. Future studies can explore other dust properties, such as hygroscopicity, surface roughness, and electrostatic charges, to investigate their influence on dust adhesion and soiling loss. Understanding these properties can lead to the development of tailored cleaning techniques and surface coatings to mitigate soiling effects. 4. Long-Term Performance Analysis: The current study focused on the short-term impact of artificially deposited dust on PV module performance. Future research can involve long-term monitoring of PV systems in real-world environments to assess the cumulative effects of dust accumulation over extended periods. This would provide insights into the long-term performance degradation and enable the development of predictive models. 41 Department of EEE, FET-JU Study of Soiling Loss on Photovoltaic Modules with Artificially Deposited Dust of Different Gravimetric Densities and Compositions Collected From Different Countries. 2022-2023 REFERENCES [1] Javed, W., Guo, B., Figgis, B., & Aïssa, B. (2021). Dust potency in the context of solar photovoltaic (PV) soiling loss. Solar Energy, 220, 1040-1052. [2] Darwish, Z. A., Sopian, K., & Fudholi, A. (2021). Reduced output of photovoltaic modules due to different types of dust particles. Journal of Cleaner Production, 280, 124317. [3] Mehmood, U., Al-Sulaiman, F. A., & Yilbas, B. S. (2017). Characterization of dust collected from PV modules in the area of Dhahran, Kingdom of Saudi Arabia, and its impact on protective transparent covers for photovoltaic applications. Solar Energy, 141, 203-209. [4] Tanesab, J., Parlevliet, D., Whale, J., & Urmee, T. (2017). Seasonal effect of dust on the degradation of PV modules performance deployed in different climate areas. Renewable Energy, 111, 105-115. [5] Tanesab, J., Parlevliet, D., Whale, J., Urmee, T., & Pryor, T. (2015). The contribution of dust to performance degradation of PV modules in a temperate climate zone. Solar Energy, 120, 147-157. [6] Mani, F., Pulipaka, S., & Kumar, R. (2016). Characterization of power losses of a soiled PV panel in Shekhawati region of India. Solar Energy, 131, 96-106. [7] Sarver, T., Al-Qaraghuli, A., & Kazmerski, L. L. (2013). A comprehensive review of the impact of dust on the use of solar energy: History, investigations, results, literature, and mitigation approaches. Renewable and sustainable energy Reviews, 22, 698-733. [8] Brown, K., Narum, T., & Jing, N. (2012, June). Soiling test methods and their use in predicting performance of photovoltaic modules in soiling environments. In 2012 38th IEEE photovoltaic specialists conference (pp. 001881-001885). IEEE. [9] John, J. J., Warade, S., Tamizhmani, G., & Kottantharayil, A. (2015). Study of soiling loss on photovoltaic modules with artificially deposited dust of different gravimetric densities and compositions collected from different locations in India. IEEE journal of photovoltaics, 6(1), 236-243. [10] Burton, P. D., & King, B. H. (2013, June). Artificial soiling of photovoltaic module surfaces using traceable soil components. In 2013 IEEE 39th Photovoltaic Specialists Conference (PVSC) (pp. 1542-1545). IEEE. [11] Kimber, A. (2007, September). The effect of soiling on photovoltaic systems located in 42 Department of EEE, FET-JU Study of Soiling Loss on Photovoltaic Modules with Artificially Deposited Dust of Different Gravimetric Densities and Compositions Collected From Different Countries. 2022-2023 arid climates. In Proceedings 22nd European Photovoltaic Solar Energy Conference. [12] Qasem, H., Betts, T. R., Müllejans, H., AlBusairi, H., & Gottschalg, R. (2014). Dust‐ induced shading on photovoltaic modules. Progress in Photovoltaics: Research and Applications, 22(2), 218-226. 43 Department of EEE, FET-JU Study of Soiling Loss on Photovoltaic Modules with Artificially Deposited Dust of Different Gravimetric Densities and Compositions Collected From Different Countries. 2022-2023 ANNEXURE – 1 CALCULATION OF POWER LOSS Maximum Power = 21.0V * 0.65A = 13.65W Now, let's calculate the power loss in each country by subtracting the power generated in each country from the maximum power. For Bhutan: Power Loss = Maximum Power - Power in Bhutan = 13.65W - (18.3V * 0.31A) = 13.65W - 5.673W = 7.977W For India: Power Loss = Maximum Power - Power in India = 13.65W - (18.1V * 0.41A) = 13.65W - 7.421W = 6.229W For Bangladesh: Power Loss = Maximum Power - Power in Bangladesh = 13.65W - (19.8V * 0.33A) = 13.65W - 6.534W = 7.116W For Nepal: Power Loss = Maximum Power - Power in Nepal = 13.65W - (19.7V * 0.27A) = 13.65W - 5.319W = 8.331W Therefore, the power loss in each country is as follows: Bhutan: 7.977W India: 6.229W Bangladesh: 7.116W Nepal: 8.331W To calculate the power loss in percentage for each country, we can use the formula: Power Loss Percentage = (Power Loss / Maximum Power) * 100. For Bhutan: Power Loss Percentage = (7.977W / 13.65W) * 100 = 58.47% For India: Power Loss Percentage = (6.229W / 13.65W) * 100 = 45.60% For Bangladesh: Power Loss Percentage = (7.116W / 13.65W) * 100 = 52.12% For Nepal: Power Loss Percentage = (8.331W / 13.65W) * 100 = 61.03% Therefore, the power loss percentages for each country are as follows: Bhutan: 58.47% India: 45.60% Bangladesh: 52.12% Nepal: 61.03% 44 Department of EEE, FET-JU Study of Soiling Loss on Photovoltaic Modules with Artificially Deposited Dust of Different Gravimetric Densities and Compositions Collected From Different Countries. 2022-2023 APPENDIX Prof. Savitha R – Project Guide Email: r.savitha@jainuniversity.ac.in Information Regarding Students: Student’s Name Permanent Address Phone Number Aniruddha Barai aniruddhabd9343@gmail.com Subhadia, Bagerhat, Bangladesh +8801913039408 Bishnu Thapa bisu.sindhuli@gmail.com Sindhuli, Nepal. +977 9860629860 Santullah Sami santullahsami2023@gmail .com Samangan, Afghanistan jigdrelwangchuk460@gmail.c om Thimphu, Bhutan Jigdrel Wangchuk Email ID 45 Department of EEE, FET-JU +93 72982099 +97577628338 Photograph
0
You can add this document to your study collection(s)
Sign in Available only to authorized usersYou can add this document to your saved list
Sign in Available only to authorized users(For complaints, use another form )