Laboratories written by Prof. Robert Niffenegger © UMass ECE 210 Lab 1: Power of AC signals and impedance matching SKILLS: • • • Generate AC wave with Signal Generator Measure AC signal with Oscilloscope Measure current with Digital Multi-meter NOTE: Failure to record your data properly, document your setup, or take notes about your procedures will leave you unable to write your lab report. Record everything! RMS voltage of Sine Wave RMS voltage of an AC signal is equivalent to the DC voltage that would dissipate the same average power. Measuring the RMS voltage and currents allows us to calculate the power in AC circuits. πππ£π = ( 2 π(π‘)2 ππππ = ) π π΄ππΊ π 1 π 2 ππππ = √ ∫ (π(π‘)) π 0 Generating AC signals: 1. Signal Generator (Agilent 33220A): i. Turn on the power ii. Waveform = SINE WAVE iii. Frequency = 1 kHz iv. Amplitude = 2.0 π½ππ (e.g. Max = 1V, Min = -1) v. Offset = 0.0V vi. Turn on the ‘output’ (lights up green) BNC Contact rniffenegger@umass.edu for permission for use outside of UMass Amherst 1 Laboratories written by Prof. Robert Niffenegger © 2. Oscilloscope (Rigol DS1104Z): i. Turn on power (bottom left button) ii. Connect the signal generator to the oscilloscope (Ch 1) with a BNC cable iii. Press the “AUTO” button on the oscilloscope to automatically range the axes. iv. Adjust the vertical ‘SCALE’ to maximize the contrast of the signal v. Adjust the horizontal ‘SCALE’ to show 10 full periods (1ms/div) 3. Press the ‘MEASURE’ button on the oscilloscope: i. Check that ‘Source’ = Channel 1 ii. Use the top left most ‘menu’ button to switch between i. ‘Vertical’ (Y-axis) measurements like RMS and peak to peak voltage ii. Horizontal (X-axis) measurements like period and frequency iii. RECORD πππ & ππ ππ (Turn on ‘Statistic’ to show the average measurement) 4. Calculate ππ ππ from πππ (Verify it matches your measurements within ±1%) Contact rniffenegger@umass.edu for permission for use outside of UMass Amherst 2 Laboratories written by Prof. Robert Niffenegger © 5. Save the oscilloscope data (with USB drive or Ultra Sigma): i. Save raw data as CSV (to plot with Python/Colab notebook) i. USB instructions 1. Press ‘Storage’ button 2. Select storage as ‘CSV’ (not picture) 3. Select ‘Save’ 4. Select ‘Disk D’ (rotate ‘intensity’ knob, then press knob) 5. Select ‘New File’ ( 6. Write down the filename (e.g. ‘NewFile5.csv’) ii. Save πππ , ππ ππ measurements with an image (screenshot or picture) for your notes iii. Label filenames clearly and save in an organized folder 6. Record details about how your data was taken: i. Sketch a diagram of all equipment used in your notes (and take a picture!) ii. Sketch the final plot (roughly draw the wave and label the axes with UNITS!) (Colab for plotting: https://colab.research.google.com/drive/1Y9S9tWtZ4kALGKMqN_7kM0ekKjPXLep?usp=sharing ) SINE Wave with offset: 1. Generator → Maximum Voltage = +1.0 V 2. Generator → Minimum Voltage = 0.0 V 3. Scope → Increase the Trigger level to +0.5V 4. RECORD πππ & ππ ππ 5. Calculate ππ ππ from πππ (< 1% error?) Triangle Wave (‘Ramp’): 1. Generator → Waveform = Triangle Wave 2. Generator → Amplitude = 2.0 π½ππ 3. Generator → Offset = 0.0 V 4. Scope → RECORD πππ & ππ ππ 5. Calculate ππ ππ from πππ (verify < 1% error) Contact rniffenegger@umass.edu for permission for use outside of UMass Amherst 3 Laboratories written by Prof. Robert Niffenegger © Current and Power measurements: 1. Waveform = SINEWAVE 2. Amplitude = 2.0 π½ππ 3. Offset = 0.0V 4. RECORD πππ & ππ ππ 5. Disconnect the oscilloscope 6. Connect the Ammeter (HP 34401A Digital Multimeter) in series I. II. III. IV. Power on Red mini-hook cable → “I” input (bottom right) Black mini-hook cable → “LO” input (center right) Connect the mini-hooks in SERIES with generator (match colors) V. Press “SHIFT” + “AC I” to measure current a. Units should be ‘AAC’ for Amps AC 7. RECORD the AC RMS current: πΌπππ [π΄π΄πΆ] Recall, the utility of RMS values is that the average power of AC signals can be calculated from their RMS values: πππ£π = πΌπππ ⋅ ππππ 8. Calculate the average power from the source using the RMS current and RMS voltage 2 9. Calculate the average power delivered to the multimeter: πππ£π = πΌπππ ⋅ 0.1Ω = ? (< 1ππ) (The DMM has very little resistance 0.1Ω, so little power is dissipated) 10. Calculate the percentage of power from the source is delivered to the load ( <1%) Very little power is delivered from the source to the load! To maximize the power transfer, we need to match impedances of the source and load. Contact rniffenegger@umass.edu for permission for use outside of UMass Amherst 4 Laboratories written by Prof. Robert Niffenegger © Impedance Matching for maximum power transfer: Next, we’ll need to confirm the output impedance of the signal generator, then insert a matching resistor in series to act as the power load. 1. Calculate the output impedance of the signal generator (~50 Ohms) π [πβππ ] = π [ππππ‘π ] πΌ[π΄πππ ] 2. Find a resistor to match this output impedance (47Ω) 3. Insert the resistor in series with the signal generator and the ammeter: 4. RECORD the AC RMS current: πΌπππ [ππ΄ π΄πΆ] 2 5. Calculate the average power delivered to the load: πππ£π = πΌπππ ⋅ π ππππ = ? (~ππ) 6. Calculate the average power driven by the source. 7. Calculate the percentage of power transferred. Now that we have inserted a load with matched impedance to the source, we see that the power transfer is much larger! Consider what would happen with a 10πΊ or 100πΊ power load? Contact rniffenegger@umass.edu for permission for use outside of UMass Amherst 5 Laboratories written by Prof. Robert Niffenegger © Voltage Divider: Now let’s confirm the voltage across the load by attaching the scope again. 1. Connect the scope in parallel with the load resistor 2. RECORD ππ ππ across the resistor with the scope You should see that the RMS voltage is now HALF of what you measured before. 3. CALCULATE the voltage drop across the generators internal output impedance of 50Ω 4. CALCULATE the voltage drop across the 50 Ω load resistor 5. Sum the two voltages and compare to the display of the generator The signal generator isn’t expecting to drive a load, so it is displaying the ‘no load’ voltage 6. Change the signal generator to display the output voltage when connected to a load: a. Press the ‘Utility’ button a. Select ‘Output Setup’ b. Should display ‘High Z Load’ in the upper right corner c. Select ‘Load’ i. Will offer option to set the expected impedance ii. Set to 50 Ohm iii. Select ‘DONE’ d. Top right will no longer display ‘High Z’ 7. Verify that the voltage displayed on the generator matches the scope We have created a voltage divider with the output impedance of the generator (50Ω) and the new 50Ω load. Δπ = πΌ ⋅ π ππ ππππ = πΌ ⋅ 50Ω πππ = πΌ ⋅ (50Ω + 50Ω) πππ πΌ= 50Ω + 50Ω ππ ππππ = πππ ππ ππππ = πππ 2 50Ω 50Ω + 50Ω Contact rniffenegger@umass.edu for permission for use outside of UMass Amherst 6 Laboratories written by Prof. Robert Niffenegger © Impedance Mismatch (display error) : 1. Remove the 50 Ohm Load resistor. 2. Move the Ammeter into series with the scope to measure current. (You will need another set of mini-hook cables to connect the scope) 3. Measure πΌπ ππ (will be too small to measure…) 4. Measure πππ The scope will show 2 πππ but the generator will display 1 πππ . The oscilloscope is correct. Removing the load resistor has removed the low impedance path for current, and the scope has a very high internal input impedance, limiting the current to almost zero (as verified with the ammeter). Without current flowing out of the generator there is no voltage drop across the internal impedance and the voltage isn’t halved. 5. Change the signal generator to back to ‘HIGH Z’ output a. Press the ‘Utility’ button b. Select ‘Output Setup’ c. Select ‘Load’ i. Set to High Z ii. Select ‘DONE’ d. Should display ‘High Z Load’ in the upper right corner 6. Verify that the voltage displayed by the generator is now correct a. Both should show 2 πππ . Please be sure to return the generator to ‘High Z’ for the next group! Contact rniffenegger@umass.edu for permission for use outside of UMass Amherst 7 Laboratories written by Prof. Robert Niffenegger © Prelab exercises: (TAs will check before lab begins) 1. Offset Sine Wave (Max = 1V, Min = 0V) a. Draw two periods of the waveform b. Calculate the RMS voltage c. Calculate the average power sourced (assuming 50 Ω internal impedance) 2. Voltage dividers: a. Starting at 1V, calculate the voltage drops across two 50 Ω resistors in series b. Draw a circuit diagram of how to connect an ammeter to measure current through these resistors. Required data for lab report: 1. CSV file of Sinewave from oscilloscope (filename?) 2. RMS measurements and calculations: Wave Theory [π½πΉπ΄πΊ ] Measured [π½πΉπ΄πΊ ] Error Sine 1/√2=0.707 0.706 V 0.14% Sine + DC offset Triangle 3. Impedance matching measurements: π½πΉπ΄πΊ (source) πΉππππ π°πΉπ΄πΊ π½πΉπ΄πΊ (load) π·ππππ π·ππππ π·ππππππ 0.1 Ω 47 Ω Contact rniffenegger@umass.edu for permission for use outside of UMass Amherst 8 Laboratories written by Prof. Robert Niffenegger © Lab Report – Rubric To develop your technical writing skills, you will write a very concise lab report. • • • • • Define concepts (Report must be a self-contained document) Diagram experimental setup (with labels) Plot results (label axes with units) Critically analyze your results by comparing to theory o Disagreement of theory and measurements on the 1-2% level is ok. o ‘User’ errors/mistakes are wrong and will not receive points Conclusion – discuss limitations of measurements and how to improve If your report appears sloppy, no one will trust your conclusions… even if they are correct 1 report/group 2-page max Points Prelab exercises 5 Introduce and define concepts 5 Experimental Setup (with diagram) 5 PLOT – Sinewave with RMS 10 TABLE – RMS measurements and calculations 10 Analysis 5 TABLE – Impedance matching data 10 Analysis 5 Conclusion 5 Total= 60 Contact rniffenegger@umass.edu for permission for use outside of UMass Amherst 9 Laboratories written by Prof. Robert Niffenegger © Oscilloscope software Saving data with this computer software is faster than using USB drives. To install, first download here: https://www.rigolna.com/products/digital-oscilloscopes/1000z/ 1. Download and install – “UltraSigma Instrument Connectivity Driver” (>500MB!!) 2. Download and install – “UltraScope Remote interface and Control SW” 3. Plug in USB in the back left of the oscilloscope and your laptop UltraSigma: 4. Launch UltraSigma (not UltraScope). Verify connection. 5. In UltraSigma: Right click on oscilloscope a. Choose >> ‘UltraScope’ UltraScope: 6. Configure measurements: Measurements tab on LEFT side of screen (click ‘ONLINE’) 7. Save DATA: Right click >> ‘Save Channel…’ Contact rniffenegger@umass.edu for permission for use outside of UMass Amherst 10
0
You can add this document to your study collection(s)
Sign in Available only to authorized usersYou can add this document to your saved list
Sign in Available only to authorized users(For complaints, use another form )