Section 2.10 SUPERHEATERS AND REHEATERS Saturated steam can be corrosive and erosive, especially to turbines. Superheaters and reheaters are used to create dry steam, which is less corrosive and erosive. Some equipment and process operations require steam below a specified temperature. For these applications, steam attemperation or temperature adjustment is needed. This section will discuss these topics, explaining the differences and applications. PRINCIPLES AND PURPOSE Heat applied to water in a closed vessel converts the water to steam. As long as any liquid remains, the temperature of the water and steam remain roughly at the saturation temperature. When all the water is evaporated, or when the steam is removed from the presence of the water, adding more heat will raise the temperature of the steam. Steam at a temperature greater than the saturation temperature is referred to as superheated steam. The difference in temperature between the superheat temperature and the saturation temperature is referred to as degrees of superheat. Superheated steam has no entrained moisture, so it is less corrosive and erosive than wet steam. For superheated turbine operations, these dry conditions are imperative. Saturated steam turbines are designed for some moisture in the steam. (See Section 2.11 Turbines.) Superheaters and reheaters function similarly in that they both serve to elevate the steam temperature above its saturation temperature. In the superheater, the steam is obtained directly from the main steam drum or header; in the reheater, the steam heated is the steam returned after it passes through a high-pressure turbine or turbine stages. In addition to reducing moisture erosion problems in turbines, superheated steam has the important advantage of being able to do more work before it condenses. Reheated superheated steam improves the cycle efficiency of a power plant by 4-5% for each 200°F (111°C) increase in superheat temperature. In general, there are two types of superheaters: integral units and separately fired units. Integral units are situated within the boiler and are by far the most common. Integral superheaters are installed directly in the path of the hot gases, but generally shielded from the radiant section in the furnace itself. The exact superheater-reheater locations depend on the particular boiler design. Integral superheaters may be called radiant or convection superheaters, depending on whether they are installed in the radiant or convection section of the boiler. (See Figure 2.10.1.) REHEATER DESIGN Reheaters and superheaters are similar in design. Reheaters are used to reheat steam that has been extracted from the turbine. For example, by utilizing a reheater, primary steam may be supplied to a high-pressure turbine at 2400 psig (16.5 MPag) and 1000°F (538°C). The steam is exhausted at 600 psig (4.1 MPag) and 600°F (316°C), reheated to 1000°F (538°C), and then passed through a second low-pressure turbine. Reheaters significantly increase the efficiency of the boiler condensing steam turbine cycle, reducing the operating costs for fuel and handling, and making their use quite advantageous in most electric utility plants. CONFIDENTIAL, For Nalco Employee Use Only ©2006 Nalco Company PAC-2 Boiler Water Technical Manual (6-06) 287 Section 2.10 SUPERHEATERS AND REHEATERS Figure 2.10.1 – Integral superheaters in a subcritical drum-type utility boiler 288 CONFIDENTIAL, For Nalco Employee Use Only ©2006 Nalco Company PAC-2 Boiler Water Technical Manual (6-06) Section 2.10 SUPERHEATERS AND REHEATERS SUPERHEATER OPERATIONAL PROBLEMS Problems in the superheater section can result in blown tubes and plant downtime. Some of the most common problems experienced in superheater tubes are discussed here. Deposition – On the steam side, deposition results from improper steam/water separation or carryover. Deposits will lay down in the inlet sections and low sections of the superheater, causing the tubes to overheat and eventually fail. Deposition on the fireside of the tubes can result in low superheat temperature and high fireside pressure drop. Tube overheating – Steam has a much lower specific heat than that of liquid water. Superheater tubes overheat when more heat is applied than can be carried off by the steam. Too high a heat input may result from broken or improper baffling or overfiring. Tube blockage (e.g., water in the tube at startup) or oxide scale buildup may prevent heat from dissipating rapidly enough. This overheating often takes the form of mild, prolonged overheating, which eventually weakens the superheater tubes and causes them to fail. Boiler water carryover into the superheater tubes will leave deposits in the superheaters, resulting in the potential of overheating the tubes. Periodic steam purity studies and fireside inspections will help keep such problems at a minimum. PROTECTION DURING START-UP During normal operation, every superheater tube must have steam flow sufficient to prevent overheating. During start-up, there is insufficient steam flow through every tube. The flue gas temperature, entering the superheater section, must be held to the following limits to control superheater metal temperature: • 900°F (482°C) for carbon steel tubes • 950-1000°F (510-538°C) for alloy tubes During start-up, the superheater drains and vents, if present, must be open to provide steam flow for cooling the tubes until the boiler reaches line pressure. If superheater drains are not present, the initial firing rate must be very low so all of the water is removed through evaporation. Although firing rate is the primary means of controlling flue gas temperature, other means such as excess air and flue gas recirculation can help prevent overheating of the superheater tubes. The two requirements for steam flow through every superheater tube are: 1. All water must be removed from each tube Corrosion – Corrosion to both the steam side and fireside is always a potential problem. Steam side corrosion can result from oxygen attack on the metal, if not protected during downtime, or from caustic concentration from boiler water carryover evaporating to dryness. Fireside corrosion normally results from the deposition of sulfur-bearing ash and soot on the tube surfaces. It is important to realize the potential problems that can occur in the superheater section and to take precautionary steps to minimize them. 2. Total steam flow must be equal to or greater than 10% of rated steam flow Header drains are used to remove water from drainable superheaters. On nondrainable units, the water must be boiled away. Care must be taken to minimize excess heat input to the tubes. Thermocouples attached to the outlet of the superheater tubes indicate saturation temperature when water remains in the tube. A substantial increase in temperature above saturation will be noticed after removing all moisture from the superheater and establishing proper flow. CONFIDENTIAL, For Nalco Employee Use Only ©2006 Nalco Company PAC-2 Boiler Water Technical Manual (6-06) 289 Section 2.10 SUPERHEATERS AND REHEATERS Superheaters normally collect some condensate when firing is stopped. This condensate must be drained or boiled out before start-up of the unit. STEAM TEMPERATURE ADJUSTMENT AND CONTROL Following are the basic reasons for adjusting and controlling steam temperature: CLEANING Internal cleaning of drainable superheaters is normally accomplished using condensate or demineralized water to remove any deposits. (Non-drainable superheaters generally cannot be flushed without the installation of a large temporary pump capable of supplying enough flow to get even distribution through all the parallel paths.) Most deposits found in superheaters are water soluble. The conductivity of the wash water gives a good indication of cleaning progress. After washing, the superheater should be drained or boiled out, as previously outlined. Cleaning requirements of the external (fireside) of the superheater vary considerably, based upon the fuel burned and deposit composition. The reason for deposition should be thoroughly analyzed, and corrective actions taken to minimize future occurrences. Never make cleaning recommendations on boiler system components without consulting Nalco technical support. Severe liabilities exist in these systems for poor performance and equipment damage. METALLURGY Table 2.10.1 lists the materials of construction commonly used in the U.S. for superheaters today. The table also establishes the maximum allowable stresses and temperatures these tubes can tolerate. 290 • To prevent overheating and failure of the superheater and reheater tubes • To prevent overheating and failure of the turbine components • To prevent thermal expansion, thereby reducing turbine clearances to the danger point • To minimize blade erosion caused from excessive steam condensation in the later stages of the turbine blades Steam temperature adjustment typically includes only off-stream methods used to affect steam temperature. On-stream methods are called steam temperature controls. The control of fluctuations in temperature caused by uncertainties of operation (such as slag or ash accumulation) has some effect on steam temperature. However, superheat and reheat steam temperatures are mainly affected by variations in steam output. (See Figure 2.10.2.) In drum-type industrial boilers, steam output and pressure are normally kept constant by firing rate, while resulting superheat and reheat steam temperatures depend upon such variables as the ratio of convection to radiant heat absorbing surface, excess air, feedwater temperature, and changes in the type of fuel burned. Standard performance from a properly operated and controlled system is a deviation of not more than 10°F (5.6°C) in the outlet superheated steam temperature. CONFIDENTIAL, For Nalco Employee Use Only ©2006 Nalco Company PAC-2 Boiler Water Technical Manual (6-06) Section 2.10 SUPERHEATERS AND REHEATERS Table 2.10.1 – Maximum allowable design stresses for superheater and reheater tubes Max. Stress for Metal Temperature not Exceeding °F, psig Material ASME Spec. Number Grade 900 950 1000 1050 1100 1150 1200 1300 Carbon Steel SA210 A1 5000 3000 - - - - - - Carbon Moly SA209 T1a 12500 8500 - - - - - - Croloy 1⁄2 SA213 T2 12500 10000 6250 - - - - - - - - - Croloy 1 1 4 ⁄ ⁄ SA213 T11 13100 11000 6550 4050 Croloy 2 1 4 SA213 T22 13100 11000 7800 5800 4200 - - - Croloy 5 SA213 T5 - - 5600 4150 3050 2000 - - Croloy 9M SA213 T9 - - 8500 5500 3300 2200 - - Croloy 18-8 SA213 TP304H* - - 13700 12150 9750 7700 6050 3700 Croloy 18-8 SA213 TP304H - - 9750 9500 8850 7700 6050 3700 Croloy 18-8 SA213 TP321H* - - 14000 11700 9050 6900 5350 3150 Croloy 18-8 SA213 TP321H - - 10450 10100 8800 6900 5350 3150 Material ASME Spec. Number Max. Stress for Metal Temperature not Exceeding °C, Mpag Grade 482 510 538 566 593 621 649 704 Carbon Steel SA210 A1 34 21 - - - - - - Carbon Moly SA209 T1a 86 59 - - - - - - Croloy 1 2 SA213 T2 86 69 43 - - - - - ⁄ Croloy 1 1 4 ⁄ SA213 T11 90 76 45 28 - - - - Croloy 2 1⁄4 SA213 T22 90 76 54 40 29 - - - Croloy 5 SA213 T5 - - 39 29 21 14 - - Croloy 9M SA213 T9 - - 59 38 23 15 - - Croloy 18-8 SA213 TP304H* - - 94 84 67 53 42 26 Croloy 18-8 SA213 TP304H - - 67 66 61 53 42 26 Croloy 18-8 SA213 TP321H* - - 97 81 62 48 37 22 Croloy 18-8 SA213 TP321H - - 72 70 61 48 37 22 *Due to relatively low yield strength of these materials, these higher stress values were established at temperatures where the short time tensile properites govern to permit the use of these alloys where slightly greater deformation is acceptable. The stress values in this range exceed 62 1/2% but do not exceed 90% of the yield strength at temperature. Use of these stesses may result in dimentional changes due to permanent strain. These stress values are not recommended for the flanges of gasketed joints of other applications where slight amounts of distortion can cause leakage or malfunction. CONFIDENTIAL, For Nalco Employee Use Only ©2006 Nalco Company PAC-2 Boiler Water Technical Manual (6-06) 291 Section 2.10 SUPERHEATERS AND REHEATERS Excess air – For a change in the amount of excess air entering at the burners, there is a corresponding change in the quantity of gas flowing over a convection superheater; therefore, an increase in excess air tends to raise the steam temperature. Feedwater temperature – An increase in feedwater temperature reduces superheat because, for a given steam flow, less fuel is fired and less gas passes over the superheater. Heating surface cleanliness – Removing ash or slag deposits from heat-absorbing surfaces ahead of the superheater reduces gas temperature and steam temperature. Removing deposits from the superheater surface increases superheater absorption and raises steam temperature. Figure 2.10.2 – Substantially uniform final steam temperature over a range of output can be attained by a series arrangement of radiant and convection superheaters Use of saturated steam – If saturated steam from the boiler is used for soot blowers or for auxiliaries, such as pumps and fans, an increased firing rate is required to maintain constant main steam output. This raises the steam temperature. VARIABLES AFFECTING FINAL STEAM TEMPERATURE Many operating variables can affect the temperature of the steam that a boiler produces; to maintain constant steam temperature, means must be provided to compensate for the variables that affect final steam temperature. Burner operation – The distribution of heat input among burners at different positions or a change in the adjustment of a burner usually has an effect on steam temperature through changes in the furnace heat-absorption rate. Load – As the load increases, the quantity and temperature of combustion gases increase. In a convection superheater, steam temperature increases with load because the quantity and temperature of combustion gases increase. In a radiant superheater, steam temperature decreases as load increases. Sometimes, a convection and a radiant superheater are installed in series in a single steam-generating unit to maintain substantially constant steam temperature over a considerable range of load. (See Figure 2.10.2.) 292 Fuel – Variations in steam temperature may result from changing the type of fuel burned or from changes in the characteristics of a given fuel from time to time. For example, changing from blast furnace gas, which releases heat higher in the boiler, to oil, which releases heat in the lower portion of the boiler, will have an impact of increasing steam temperature. CONFIDENTIAL, For Nalco Employee Use Only ©2006 Nalco Company PAC-2 Boiler Water Technical Manual (6-06) Section 2.10 SUPERHEATERS AND REHEATERS ADJUSTMENT OF STEAM TEMPERATURE Adjustment of steam temperature means a change in the arrangement of equipment, which affects the final steam temperature, but cannot be used to vary the temperature during actual operation. An example of temperature adjustment is the installation or removal of superheater tubes. Importance of Adjustment Power-generating units today represent a large capital investment, and means should be provided to regulate steam temperature to meet any changes affecting the system. For instance, a change in the type of fuel a unit burns will affect the resultant steam temperature considerably. Adjustments in equipment design will be necessary unless the plant controls (e.g., attemperation) can compensate for such changes. Means of Adjustment The following methods can be used to adjust steam temperature: • The basic method of steam temperature adjustment is to add or remove superheater or reheater tubes • Another method is to reduce or increase the amount of saturated surface ahead of the steam-heating elements. Such alterations modify the gas temperature at the inlet to these elements. Removing saturated surface to increase steam temperature is relatively simple and, in general, costs less than adding steamheating elements. However, adding saturated surface in order to decrease steam temperature can be difficult and expensive, or, in some cases, impractical. • The gas temperature at the superheater inlet can also be adjusted by changing the effectiveness of the heat-absorbing surface in the furnace. This is accomplished by adding or removing refractory covering on parts of the furnace surface. While a refractory coating on water-cooled furnace surfaces can have a favorable effect on combustion and carbon loss, it should not be added in areas where undesirable ash would deposit. • One of the simplest, least expensive, and most effective means of adjustment is to change the gas mass velocity over the steam-heating elements by baffle changes, if the design of the unit will permit such changes. Several of the standardized boilers, especially in the smaller sizes, have an adjustable baffle suitable for steam-temperature regulation. This design makes it possible to vary the steam temperature range as much as 20%. The limit of variation is the effect on draft loss and efficiency. CONTROL OF STEAM TEMPERATURE Control of steam temperature may consist of one of the following: • Regulating steam pressure during actual operation (generally not practical) • Direct spray attemperation • Attemperation using a heat exchanger, e.g., a heat exchanger in the bottom drum • By-passing hot gases past the superheater Importance of Steam Control Controls must be used to regulate steam temperature within required limits. The primary reason for regulating steam temperature is that ash deposits can form on the tube surface of both the steam generating section and the superheater sections. This condition can usually be corrected by simple changes in the operating schedules of soot and slag blowers along with fuel treatment. To hold the optimum heat rate of a turbine designed to use full first-stage pressure over a given load range, the steam temperature must be regulated over this range by an effective means of control. CONFIDENTIAL, For Nalco Employee Use Only ©2006 Nalco Company PAC-2 Boiler Water Technical Manual (6-06) 293 Section 2.10 SUPERHEATERS AND REHEATERS The time in which a turbine may be brought to full load is established by the turbine manufacturer in accordance with a safe steam temperature-time curve. Because the temperature of the steam is directly related to the degree of expansion of the turbine elements, and consequently the maintenance of safe clearances, it must be regulated within permissible limits by some means of accurate control. The removal of feedwater heaters for servicing is an example of variable operation. Maintaining the same load with feedwater heaters out requires an increase in the heat input to the boiler unit, with a corresponding increase in superheater or reheater absorption. Unless some means of control is available for regulating steam temperature to cover this condition, a drop in load might be required to protect both the superheater tubes and the turbine. Methods of Controlling Steam Temperature There are numerous methods for controlling steam temperature. The choice depends on the particular boiler system design and operation. Following are the most commonly used methods of controlling steam temperature: Separately fired superheater – A superheater completely separate from the steam generating unit and independently fired may serve one or several saturated steam boilers. This arrangement is not generally economical for power generation, where a large quantity of hightemperature steam is needed. Its use is largely confined to process industries, such as chemical manufacture and petroleum refining, to meet special requirements. Because heat absorption can be varied independent of the quantity of steam delivered, the separately fired superheater has great flexibility in operation and a wide range of steam temperature regulation at all loads. Either oil or natural gas is customarily used as fuel. (See Figure 2.10.3.) 294 Excess air – Boiler operators have long known that the steam outlet temperature of a convection superheater on a drum- or separator-type unit can be increased at fractional loads by decreasing the furnace heat absorption through an increase in the amount of excess combustion air. Additional volumes of excess air result in higher gas velocities and less contact time in the furnace. The resulting greater gas weight to the stack increases the stack loss, but the drop in boiler efficiency is made up to some extent with an increase in turbine efficiency. Such an arrangement is illustrated in Figure 2.10.4. Gas recirculation – One of the most attractive methods of controlling superheat or reheat, both from economic and operational viewpoints, is gas recirculation. As the name implies, this involves a method by which gas from the boiler, economizer, or air heater outlet is reintroduced to the furnace by means of a suitable fan and ducts. In the following discussion, recirculated gas introduced in the immediate vicinity of the initial burning zone of the furnace and used for steam temperature control will be referred to as “gas recirculation”; recirculated gas introduced near the furnace outlet and used for control of gas temperature will be referred to as “gas tempering”. Figure 2.10.5 shows an application of gas recirculation on a hopper-bottom radiant boiler. In most instances, the gas is obtained from the economizer outlet. The effect desired dictates the point of reintroduction. The recirculated gas should be introduced into the furnace so that interference with the combustion of the fuel is avoided. The amount of recirculated gas is generally expressed as a percentage of the gas that remains after the point of take-off of the recirculated gas. Recirculated gas may be used for several purposes; however, its basic function is to provide a means of altering the heat-absorption pattern within a steam generating unit. An important feature of recirculated gas is that its use changes only the pattern of heat absorption CONFIDENTIAL, For Nalco Employee Use Only ©2006 Nalco Company PAC-2 Boiler Water Technical Manual (6-06) Section 2.10 SUPERHEATERS AND REHEATERS Figure 2.10.3 – Typical arrangements for separately fired superheaters through a boiler. Its effect on the total boiler heat absorption, the gas weight up the stack, and the boiler efficiency is negligible. Figure 2.10.6 shows the variation in heat absorption with gas recirculation introduced into the hopper. Introduction of gas at this location produces a marked reduction in furnace absorption and increases the absorption of the convection section. The total heat absorption remains unchanged. Furnace heat absorption is primarily a function of the gas temperature and gas-temperature patterns throughout the furnace, because the heat is transferred mainly be radiation. Hence, the introduction of gas recirculation into the furnace hopper reduces furnace absorption by altering the gas-temperature pattern. The major portion of the heat absorbed in the superheater, reheater, and economizer is transferred by convection, which depends on gas temperature and gas mass velocity. Both are affected by gas recirculation. Therefore, when the gas mass velocity through a convection bank is increased by gas recirculation, the amount of heat transferred may increase, decrease, or remain unchanged, depending on the changes in the relationship between gas temperature and CONFIDENTIAL, For Nalco Employee Use Only ©2006 Nalco Company PAC-2 Boiler Water Technical Manual (6-06) 295 Section 2.10 SUPERHEATERS AND REHEATERS Figure 2.10.4 – Steam temperature control by use of increased excess air 296 CONFIDENTIAL, For Nalco Employee Use Only ©2006 Nalco Company PAC-2 Boiler Water Technical Manual (6-06) Section 2.10 SUPERHEATERS AND REHEATERS Figure 2.10.5 – One arrangement for gas recirculation CONFIDENTIAL, For Nalco Employee Use Only ©2006 Nalco Company PAC-2 Boiler Water Technical Manual (6-06) 297 Section 2.10 SUPERHEATERS AND REHEATERS control can be improved by distributing the burners over a considerable height of the burner wall or by installing a special burner near the furnace outlet. Movable burners – Regulation of steam temperature by changing the furnace absorption pattern can also be effected by the use of movable burners operated to shift the main combustion zone in the furnace. Burners that can be tilted are used for this purpose. Gas by-pass – If the convection banks of a steam-generating unit are separated by gas-tight baffles into two or more parallel gas passes isolating portions of the superheater and reheater surfaces, the proportion of gas flow over all or part of the superheater and reheater may be varied by regulating dampers. This method has the advantage of low initial cost. Disadvantages include the following: Figure 2.10.6 – Effect of gas recirculation on heat absorption pattern at constant firing rate • It is difficult to keep the dampers operable unless they are placed in a cool gas zone gas weight entering the bank. Figure 2.10.6 illustrates a condition in which the gas temperature entering the secondary superheater (furnace exit temperature) is relatively unchanged by gas recirculation. Therefore, increasing the amount of gas recirculation increases the heat absorption in the secondary superheater. The heat absorption in the reheater, primary superheater, and economizer is also increased, with the greatest increase occurring at the cold end of the unit. This is a typical example of variation in the convection pass heat absorption pattern gas recirculation. Burner selection – Steam temperature can often be regulated by selective burner operation. High steam temperature may be obtained at less than full load by operating only the burners giving the highest furnace outlet temperature. When lower steam temperature is required, firing may be shifted to the other burners. This method of 298 • Draft loss through the unit is increased for some designs, particularly if control is desired with alternate fuels • Control is more sluggish than with attemperators • High gas temperature exists at the bypass dampers unless there is a heat-absorbing surface in the pass Attemperation – All of the methods discussed above are based on varying the amount of heat absorbed by the steam-heating elements. In the two most common types of attemperators, steam temperature is regulated by removing heat from the steam or by diluting higher temperature steam with lower temperature water. The attemperator may be located in one of three places: 1. Between the saturated steam outlet and the superheater CONFIDENTIAL, For Nalco Employee Use Only ©2006 Nalco Company PAC-2 Boiler Water Technical Manual (6-06) Section 2.10 SUPERHEATERS AND REHEATERS 2. At some intermediate point between two sections of the superheater 3. At the superheater outlet An attemperator located before the superheater will condense some of the saturated steam passing through it and will deliver wet steam of reduced enthalpy to the superheater. There are important advantages to locating an attemperator between two stages of a superheater. With this arrangement, the average steam temperature never exceeds the final steam temperature desired. Additionally, the steam from the various circuits of the first-stage superheater is so thoroughly mixed that it enters the second-stage superheater at a uniform temperature. This is, therefore, the most preferred location. Its only disadvantage is the amount of piping required from the first-stage superheater to the attemperator and from the attemperator to the second-stage superheater. Attemperators may be classified into two types: surface and direct contact. In the surface type, steam is isolated from the cooling medium by the heat exchanger surface. In the direct-contact type, the steam and the cooling medium (water) are mixed. The surface attemperator includes both shell and drum types. The direct-contact attemperator is exemplified by the spray type. When a drum-type attemperator (Figures 2.10.7 and 2.10.8), located in the mud drum, is used interstage, a part of the steam from the primary superheater is diverted to it by an automatic valve. The diverted steam is reduced in temperature by giving up heat to the boiler water. It is then mixed with the rest of the steam from the primary superheater and passes on to the secondary superheater. The final temperature of the steam is regulated by the position of the automatically operated valve that controls the amount of steam diverted through the attemperator. Figure 2.10.7 – Drum-type surface attemperator In the shell-type surface attemperator, the superheated steam flows through a bundle of tubes fitted in a cylindrical shell through which cooling water circulates. A valve in the base of the shell diverts the proper proportion of the superheated steam (through the tubes) to give the final steam temperature desired. The shell is connected to the boiler circulating system, assuring a positive flow of water in the shell at all times. Thermal-sleeve ferrules at the steam inlet ends connect the tubes to an inlet box, which protects the tubesheets from severe thermal stresses. Disadvantages of this type of attemperator are the relative inaccessibility of the tubes and tubesheet for inspection. The direct-contact type spray attemperator (Figure 2.10.9) has proved most satisfactory for regulating steam temperature. High-purity water is introduced into the superheated steam line through a spray nozzle at the throat of a venturi section within the line. Because of the spray action at the nozzle and the high velocity of the steam through the venturi throat, the water vaporizes, mixes with, and cools the superheated steam. An important feature of construction is the continuation of the venturi section into a thermal sleeve, downstream from the spray CONFIDENTIAL, For Nalco Employee Use Only ©2006 Nalco Company PAC-2 Boiler Water Technical Manual (6-06) 299 Section 2.10 SUPERHEATERS AND REHEATERS Figure 2.10.8 – Automatic control for drum-type attemperator 300 CONFIDENTIAL, For Nalco Employee Use Only ©2006 Nalco Company PAC-2 Boiler Water Technical Manual (6-06) Section 2.10 SUPERHEATERS AND REHEATERS nozzle, to protect the high-temperature piping from thermal shock that could result from any incompletely evaporated water droplets striking the hot surface of the piping. The spray attemperator provides a quick acting, sensitive means of regulating steam temperature. The spray water must be of highest purity, since solids entrained in the spray water enter the steam and may, if excessive, cause troublesome deposits on superheater tubes, piping, or turbine blades. High-pressure heater drains are a source of extremely pure water, but they require a separate high-pressure corrosion-resistant pump if used to supply the attemperator. Boiler feedwater may be satisfactory, provided that only volatile treatment chemicals are present and that only polished deionized makeup water is used. A sweet water condenser can be used to provide a source of high-purity water for attemperation. A sweet water condenser is a stainless steel, or other corrosion resistant alloy tube and shell condenser that uses boiler feedwater as a coolant source and saturated steam as the source of the condensate. High-purity polished condensate or condensate from a sweet water condenser are the preferred sources of attemperator water. Figure 2.10.9 – Spray attemperator showing thermal sleeve CONFIDENTIAL, For Nalco Employee Use Only ©2006 Nalco Company PAC-2 Boiler Water Technical Manual (6-06) 301 Section 2.10 SUPERHEATERS AND REHEATERS For your notes This page has been intentionally left blank. 302 CONFIDENTIAL, For Nalco Employee Use Only ©2006 Nalco Company PAC-2 Boiler Water Technical Manual (6-06)
0
You can add this document to your study collection(s)
Sign in Available only to authorized usersYou can add this document to your saved list
Sign in Available only to authorized users(For complaints, use another form )