Exertherm® Alarm Relay Module XL ARM XL Installation & Setup Manual There are 3 hardware connection options for use with the ARM XL. Instructions detailed in Sections 3 to 8 are generic and applicable to all, and therefore must be adhered to for all hardware selections. Following this please refer to the relevant Section for your selected hardware connection: • 8ch Datacard Only Section 9 • MMA Only Section 10 • Both 8ch Datacard & MMA Section 11 Optional Hardware: • Exertherm Temperature/Humidity Sensor Section 12 820208 MA-131-4-EN Exertherm® ARM XL Setup & Install Guide CONTENTS 1. Version Change Control Record ............................................................................................................................. 4 2. Ownership, Notes and Critical Disclaimers ............................................................................................................ 5 2.1 2.2 2.3 2.4 2.5 2.6 Notices:........................................................................................................................................................................... 5 Intellectual Property, Patents, Trade Marks and Registered Designs............................................................................. 5 Standards and approvals ................................................................................................................................................ 5 Personnel Qualification and Training ............................................................................................................................. 6 Warranty ........................................................................................................................................................................ 6 Live Working ................................................................................................................................................................... 6 3. Topologies ............................................................................................................................................................. 7 3.1 3.2 3.3 ARM XL & 8ch Datacard Connection topology ............................................................................................................... 7 ARM XL & MMA Connection Topology ........................................................................................................................... 8 ARM XL – 8ch Datacard & MMA Connection Topology .................................................................................................. 9 4. Glossary............................................................................................................................................................... 10 5. What’s in the Box? .............................................................................................................................................. 11 6. Mounting Instructions ......................................................................................................................................... 12 6.1 6.2 Unit Size ........................................................................................................................................................................ 12 Panel Cutout ................................................................................................................................................................. 13 7. Connections......................................................................................................................................................... 14 7.1 7.2 7.3 7.4 7.4.1 7.4.2 8. Caution ......................................................................................................................................................................... 14 Power Supply ................................................................................................................................................................ 14 Relay Outputs ............................................................................................................................................................... 15 Communication / Connectivity with Exertherm devices .............................................................................................. 16 Exertherm Device Numbering ...................................................................................................................................... 17 Communication Alarms ................................................................................................................................................ 17 Configuration And Setup ..................................................................................................................................... 19 8.1 8.1.1 8.1.2 8.1.3 8.2 8.2.1 9. Initial setup / Configuration ......................................................................................................................................... 19 Enabling / Disabling 8ch Datacards only ....................................................................................................................... 20 Enabling / Disabling MMA’S only .................................................................................................................................. 21 Enabling / Disabling both 8ch Datacards & MMA’S ...................................................................................................... 22 Changing Hardware Selection ...................................................................................................................................... 23 Changing Hardware Selection Procedure ..................................................................................................................... 23 User Guide– ARM XL & 8ch Datacard Only .......................................................................................................... 27 9.1 9.1.1 9.1.2 9.2 9.2.1 9.2.2 9.2.3 9.3 9.4 9.5 Home / 8CH Datacard View Screen .............................................................................................................................. 27 Sensor view & warning alarms ..................................................................................................................................... 28 Viewing Warning Alarms .............................................................................................................................................. 30 System Settings ............................................................................................................................................................ 32 Enable / Disable 8ch Datacards .................................................................................................................................... 33 Set critical alarm level .................................................................................................................................................. 34 8ch Datacard - Set TCP / IP Settings ............................................................................................................................. 35 Obtaining raw data from the ARM XL........................................................................................................................... 37 Internal Modbus TCP Registers for 8ch datacard ......................................................................................................... 38 8CH Datacard IO List ..................................................................................................................................................... 39 10. User Guide – ARM XL & MMA Only ..................................................................................................................... 40 10.1 10.1.1 10.1.2 10.2 10.2.1 10.2.2 10.3 10.4 10.4.1 10.4.2 10.4.3 10.4.4 10.4.5 10.5 Page 1 of 70 Home / MMA View Screen ........................................................................................................................................... 40 MMD status Screen ...................................................................................................................................................... 41 MMD Sensor view & alarms ......................................................................................................................................... 42 System Settings ............................................................................................................................................................ 44 Enable / Disable MMA .................................................................................................................................................. 45 MMA – Set TCP / IP Settings ......................................................................................................................................... 46 Obtaining raw data from the ARM XL........................................................................................................................... 48 Internal Modbus TCP Registers for MMA ..................................................................................................................... 49 Internal Modbus TCP Registers for MMA 20 ................................................................................................................ 49 Internal Modbus TCP Registers for MMA 21 ................................................................................................................ 50 Internal MOdbus TCP Registers for MMA 22................................................................................................................ 51 Internal MOdbus TCP Registers for MMA 23................................................................................................................ 52 Internal Modbus TCP Registers for MMA 24 ................................................................................................................ 53 MMA IO List .................................................................................................................................................................. 54 ©Exertherm 2021 Global: +44 (0)1582 461123 USA: +1 646 512 5727 E: Sales@Exertherm.com MA-131-4-EN Exertherm® ARM XL Setup & Install Guide 11. User Guide – ARM XL with both 8CH Datacard + MMA ........................................................................................ 55 11.1 11.1.1 Home / 8CH Datacard & MMA View Screen ................................................................................................................. 55 8CH Datacard & MMA Status Screen............................................................................................................................ 56 12. User Guide – Addition of Exertherm Temp / Humidity Sensor to ARM XL ........................................................... 57 12.1 12.2 12.3 12.4 12.5 12.6 12.7 Installing the Exertherm Temp / Humidity Sensor ....................................................................................................... 57 Exertherm Temp/Humidity Sensor Wiring DIagram ..................................................................................................... 57 Internal Default Settings for Exertherm Temp/Humidity Sensor ................................................................................. 58 Home View SCreen ....................................................................................................................................................... 59 Exertherm Temp/Humidity Sensor Values & Alarms .................................................................................................... 60 Exertherm Temp /Humidity Sensor Alarms wiring diagram ......................................................................................... 60 Exertherm Temperature / Humidity Sensor Datasheet ................................................................................................ 61 13. Upgrading ARM XL Software ............................................................................................................................... 64 13.1 13.2 Getting Started ............................................................................................................................................................. 64 ARM XL Upgrade Process ............................................................................................................................................. 65 14. ARM XL Datasheet ............................................................................................................................................... 69 TABLE OF FIGURES FIGURE 1 ARM XL & 8CH DATACARD CONNECTION TOPOLOGY ............................................................................................................ 7 FIGURE 2 ARM XL & MMA CONNECTION TOPOLOGY......................................................................................................................... 8 FIGURE 3 ARM XL - 8CH DATACARD & MMA CONNECTION TOPOLOGY ................................................................................................. 9 FIGURE 4 ARM XL UNIT DIMENSIONS ............................................................................................................................................ 12 FIGURE 5 POWER SUPPLY CONNECTIONS ......................................................................................................................................... 14 FIGURE 6 RELAY OUTPUTS ............................................................................................................................................................ 15 FIGURE 7 COMMUNICATION TO EXERTHERM DEVICES – RJ45 TO COM1 .............................................................................................. 16 FIGURE 8 COMMUNICATION ALARM ............................................................................................................................................... 18 FIGURE 9 COMMS ALARM - NETWORK BROKEN................................................................................................................................. 18 FIGURE 10 ARM XL INITIAL SETUP/ CONFIGURATION ........................................................................................................................ 19 FIGURE 11 INITIAL SETUP / CONFIG - ENABLING/DISABLING 8CH DATACARDS ONLY ................................................................................. 20 FIGURE 12 ENABLING / DISABLING MMA ONLY ................................................................................................................................ 21 FIGURE 13 ENABLING / DISABLING BOTH 8CH DATACARDS & MMAS ................................................................................................... 22 FIGURE 14 SETTINGS - INITIAL PASSWORD SCREEN ............................................................................................................................ 23 FIGURE 15 SETTINGS - PASSWORD ACCEPTED SCREEN ........................................................................................................................ 24 FIGURE 16 HOME / 8CH DATACARD VIEW SCREEN ............................................................................................................................ 27 FIGURE 17 SENSOR VIEW & WARNING ALARMS ............................................................................................................................... 28 FIGURE 18 8CH DATACARD - SENSOR NAME CHANGE KEYPAD .............................................................................................................. 28 FIGURE 19 DATACARD IN ALARM .................................................................................................................................................... 30 FIGURE 20 SENSOR VIEW - SENSOR SHOWING WARNING ALARM........................................................................................................... 30 FIGURE 21 WARNING ALARM RESET ............................................................................................................................................... 31 FIGURE 22 SYSTEM SETTINGS - ENABLING/DISABLING 8CH DATACARDS ONLY ......................................................................................... 33 FIGURE 23 SETTING CRITICAL ALARM LEVEL ..................................................................................................................................... 34 FIGURE 24 ARM XL TCP/IP SETTING ............................................................................................................................................. 35 FIGURE 25 ARM XL ETHERNET PORT ............................................................................................................................................. 37 FIGURE 26 HOME / MMA VIEW SCREEN ........................................................................................................................................ 40 FIGURE 27 MMD VIEW SCREEN .................................................................................................................................................... 41 FIGURE 28 MMD SENSOR VIEW & ALARMS - HEALTHY ..................................................................................................................... 42 FIGURE 29 MMD SENSOR VIEW & ALARMS - ACTIVE ALARM ............................................................................................................. 43 FIGURE 30 SYSTEM SETTINGS - ENABLING/DISABLING MMA ONLY ...................................................................................................... 45 FIGURE 31 ARM XL TCP/IP SETTING ............................................................................................................................................. 46 FIGURE 32 ARM XL TCP/IP PORT................................................................................................................................................. 48 FIGURE 33 HOME / 8CH DATACARD & MMA VIEW SCREEN ............................................................................................................... 55 FIGURE 34 EXERTHERM TEMP/HUMIDITY SENSOR TO ARM XL WIRING DIAGRAM.................................................................................. 57 FIGURE 35 DEFAULT SETTINGS & CONNECTIONS FOR EXERTHERM TEMP/HUMIDITY SENSOR..................................................................... 58 FIGURE 36 HOME SCREEN SHOWING EXERTHERM TEMP / HUMIDITY SENSOR ENABLED............................................................................ 59 FIGURE 37 EXERTHERM TEMP / HUMIDITY SENSOR VALUES & ALARMS................................................................................................. 60 Page 2 of 70 ©Exertherm 2021 Global: +44 (0)1582 461123 USA: +1 646 512 5727 E: Sales@Exertherm.com MA-131-4-EN Exertherm® ARM XL Setup & Install Guide FIGURE 38 EXERTHERM TEMP / HUMIDITY SENSOR ALARMS WIRING DIAGRAM ..................................................................................... 60 FIGURE 39 SOFTWARE UPGRADE - ARM XL SETUP SCREEN ................................................................................................................ 64 LIST OF TABLES TABLE 1 INTERNAL MODBUS TCP REGISTERS FOR 8CH DATACARD ........................................................................................................ 38 TABLE 2 INTERNAL MODBUS TCP REGISTERS FOR MMA 20 ............................................................................................................... 49 TABLE 3 INTERNAL MODBUS TCP REGISTERS FOR MMA 21 ............................................................................................................... 50 TABLE 4 INTERNAL MODBUS TCP REGISTERS FOR MMA 22 ............................................................................................................... 51 TABLE 5 INTERNAL MODBUS TCP REGISTERS FOR MMA 23 ............................................................................................................... 52 TABLE 6 INTERNAL MODBUS TCP REGISTERS FOR MMA 24 ............................................................................................................... 53 Page 3 of 70 ©Exertherm 2021 Global: +44 (0)1582 461123 USA: +1 646 512 5727 E: Sales@Exertherm.com MA-131-4-EN Exertherm® ARM XL Setup & Install Guide 1. VERSION CHANGE CONTROL RECORD Page 4 of 70 Version No Reason for Change Created by Date of Release MA-131-1-EN New product JH/LK 19th April 2018 MA-131-2-EN Addition of Exertherm Temp/humidity sensor JH/LJK 27th September 2018 MA-131-3-EN New IO Sheet + drawing updates JH/LJK 14th April 2020 MA-131-4-EN Company name change updates LJK 28th April 2021 ©Exertherm 2021 Global: +44 (0)1582 461123 USA: +1 646 512 5727 E: Sales@Exertherm.com MA-131-4-EN Exertherm® ARM XL Setup & Install Guide 2. OWNERSHIP, NOTES AND CRITICAL DISCLAIMERS NO PART OF THIS MANUAL MAY BE COPIED OR REPRODUCED VIA ANY MEANS WITHOUT THE PRIOR WRITTEN CONSENT OF EXERTHERM. THIS MANUAL & IT’S CONTENTS ARE SUBJECT TO CHANGE WITHOUT NOTICE. This document, including all the descriptions within it, assumes that the user is conversant with the operation and uses of basic control and monitoring systems. In addition, this document does not include any specific documentation concerning the systems with which integration takes place. The user should seek additional information from the supplier’s documentation for each of the connected systems. Where devices such as display panels and personal computers are used, we have assumed that the user will either be familiar with the operation of the devices or will be able to familiarise themselves with the information supplied with the equipment. The utility, configuration, terminal or stream modes of the connected systems enable all control parameters to be changed. Qualified persons only should carry this out, and it is strongly recommended that any changes made be recorded at the time of the changes. Note that if a change is to be made, a backup of the systems concerned should be made before this where possible. 2.1 NOTICES: The information, products and specifications, configurations, and other technical information regarding the products and data contained in this document are subject to change without notice. All the statements, technical information, and recommendations contained in this document are believed to be accurate and reliable but are presented without warranty of any kind, and users must take full responsibility for the application of any products or data specified in this document. IN NO EVENT SHALL EXERTHERM, OR ITS SUPPLIERS BE LIABLE FOR ANY INDIRECT, SPECIAL, CONSEQUENTIAL, OR INCIDENTAL DAMAGES, INCLUDING, WITHOUT LIMITATION, LOST PROFITS OR LOSS OR DAMAGE TO EQUIPMENT OR DATA OF ANY KIND WHATSOEVER ARISING OUT OF THE USE OR INABILITY TO USE THIS DOCUMENT, EVEN IF EXERTHERM HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. THIS LIMITATION OF LIABILITY WILL PREVAIL OVER ANY OTHER TERMS & CONDITIONS RELATING TO THE SUPPLY OF EXERTHERM PRODUCTS / SERVICES. 2.2 INTELLECTUAL PROPERTY, PATENTS, TRADE MARKS AND REGISTERED DESIGNS Exertherm is a registered trademark. The Exertherm suite of products contain proprietary information and intellectual property of Exertherm. Exertherm will vigorously protect itself in the event of any misuse of any or all such intellectual property. All other products or services referred to in this document are the trademarks, service marks, or product names of their respective holders. 2.3 STANDARDS AND APPROVALS Exertherm ARM XL, MMA, MMD, 8ch Modbus Datacard & IR + Cable Sensors are all CE certified & UL Listed. Exertherm declare that all our components are produced in accordance with EU Directive 2011/65/EU requirement for RoHS Compliance. Page 5 of 70 ©Exertherm 2021 Global: +44 (0)1582 461123 USA: +1 646 512 5727 E: Sales@Exertherm.com MA-131-4-EN Exertherm® ARM XL Setup & Install Guide 2.4 PERSONNEL QUALIFICATION AND TRAINING It is assumed that the Exertherm ARM XL Product will only be installed in accordance with the instruction contained within this Manual. Personal responsibilities, competence and supervision must be clearly defined by the commissioner / installer. If the personnel in question are not already in possession of the requisite knowledge, then appropriate training and instruction must be provided. 2.5 WARRANTY Exertherm ARM XL Return/Warranty Policy Exertherm offers a one year warranty on ARM XL Product from date of sale. We warrant that product will be free of defects in material and workmanship and will repair or replace the returned product at no charge during that one year period. The warranties are void if the product is misused, mishandled or installed incorrectly (not in accordance with the methods and procedures outlined in this document). Repairs to Exertherm ARM XL Product can only be undertaken by Exertherm. Any repairs or attempted repairs by others will void product warranties. The warranty is conditional upon the above caveats and strictly limited to the replacement cost of ARM XL Product. Labour costs associated with removal of ARML XL Product and/or re-installation are excluded, as is any consequential loss resulting from the ARM XL Product failure. Exertherm reserves the right to examine and test any returned products to determine the cause of failure. No returned products will be accepted prior to issue of a Return Material Authorization (RMA) number by Exertherm. Please contact Exertherm if you have any questions – support@Exertherm.com, current telephone numbers can be found at www.Exertherm.com . 2.6 LIVE WORKING DO NOT PERFORM ANY ACTIVITY ON A PIECE OF LIVE SWITCHGEAR. FAILURE TO COMPLY WITH THESE AND OTHER NATIONAL, REGIONAL OR LOCAL HEALTH AND SAFETY REGULATIONS/GUIDELINES COULD RESULT IN PERMANENT INJURY OR DEATH. Prior to undertaking any work the operator MUST ensure that all busbars, connections and sources of energy are totally isolated and checked prior to any works taking place which should be completed by a competent and suitably qualified person. All energy sources onto the panel must be isolated, removed and locked out to prevent the panel being re-energised while any works are taking place. If the panel being tested is part of an existing installation then all connections should be bonded to earth. Page 6 of 70 ©Exertherm 2021 Global: +44 (0)1582 461123 USA: +1 646 512 5727 E: Sales@Exertherm.com MA-131-4-EN Exertherm® ARM XL Setup & Install Guide 3. TOPOLOGIES 3.1 ARM XL & 8CH DATACARD CONNECTION TOPOLOGY Addressed 10 … 19 10 19 Figure 1 ARM XL & 8ch Datacard Connection Topology Page 7 of 70 ©Exertherm 2021 Global: +44 (0)1582 461123 USA: +1 646 512 5727 E: Sales@Exertherm.com MA-131-4-EN Exertherm® ARM XL Setup & Install Guide 3.2 ARM XL & MMA CONNECTION TOPOLOGY Figure 2 ARM XL & MMA Connection Topology Page 8 of 70 ©Exertherm 2021 Global: +44 (0)1582 461123 USA: +1 646 512 5727 E: Sales@Exertherm.com MA-131-4-EN Exertherm® ARM XL Setup & Install Guide 3.3 ARM XL – 8CH DATACARD & MMA CONNECTION TOPOLOGY Figure 3 ARM XL - 8ch Datacard & MMA Connection Topology Page 9 of 70 ©Exertherm 2021 Global: +44 (0)1582 461123 USA: +1 646 512 5727 E: Sales@Exertherm.com MA-131-4-EN Exertherm® ARM XL Setup & Install Guide 4. GLOSSARY WORD / ACRONYM Page 10 of 70 DEFINITION ARM XL Alarm Relay Module XL MMS MCC Modbus Solution – name for system as a whole MMD MCC Modbus Datacard MMA MCC Modbus Aggregator ©Exertherm 2021 Global: +44 (0)1582 461123 USA: +1 646 512 5727 E: Sales@Exertherm.com MA-131-4-EN Exertherm® ARM XL Setup & Install Guide 5. WHAT’S IN THE BOX? Part Number & description of box contents below: Exertherm Part No. 900451 1) 2) 3) 4) 5) Exertherm Alarm Relay Module (ARM XL) ARM XL Install & Setup Manual 2 x mounting screws & 1 x power connector Panel cut out Template Comms Cable Replacement Parts: The following replacement parts can be ordered, part numbers + description below: 1) Comms Cable is – PN 800445 2) 2 x mounting screws & 1 x power connector – PN 800456 Page 11 of 70 ©Exertherm 2021 Global: +44 (0)1582 461123 USA: +1 646 512 5727 E: Sales@Exertherm.com MA-131-4-EN Exertherm® ARM XL Setup & Install Guide 6. MOUNTING INSTRUCTIONS 6.1 UNIT SIZE Figure 4 ARM XL Unit Dimensions Page 12 of 70 ©Exertherm 2021 Global: +44 (0)1582 461123 USA: +1 646 512 5727 E: Sales@Exertherm.com MA-131-4-EN Exertherm® ARM XL Setup & Install Guide 6.2 PANEL CUTOUT The panel which the ARM XL is to mounted in must not be greater than 5 mm (0.2 “) thick. 1. Make a panel cut-out measuring 111.0 x 80.0mm (4.4” x 3.1”) Please use the self-adhesive template provided in ARM XL box or create your own template using the measurements above Page 13 of 70 2. Slide the ARM XL into the cut-out. 3. Push the mounting brackets into their slots on the side of the unit. 4. Tighten the bracket screws against the panel. Hold the bracket securely against the unit while tightening the screw. 5. When properly mounted, the ARM XL is squarely situated in the panel cut-out. ©Exertherm 2021 Global: +44 (0)1582 461123 USA: +1 646 512 5727 E: Sales@Exertherm.com MA-131-4-EN Exertherm® ARM XL Setup & Install Guide 7. CONNECTIONS 7.1 CAUTION Do not touch live wires. Install an external circuit breaker. Guard against short-circuiting in external wiring. Use appropriate circuit protection devices. Unused pins should not be connected. Ignoring this directive may damage the ARM XL. Double-check all wiring before turning on the power supply. To avoid damaging the wire, do not exceed a maximum torque of 0.5 N·m (5 kgf·cm). Do not use tin, solder, or any substance on stripped wire that might cause the wire strand to break. Install at maximum distance from high-voltage cables and power equipment. 7.2 POWER SUPPLY ➢ The ARM XL requires a 24VDC power supply ±15% (20.4 to 27.6) 300mA max ➢ The power supply must include double insulation. Outputs must be rated as SELV/PELV/Class 2/Limited Power. ➢ Use separate wires to connect the functional earth line (pin 3) to the system earth ground. ➢ Do not connect either the ‘Neutral’ or ‘Line’ signal of a 110/220 VAC source to the ARM XL ➢ In the event of voltage fluctuations or non-conformity to power supply voltage specifications, connect the ARM XL to a regulated power supply. PIN 3 = Earth Ground PIN 1 = Positive PIN 2 = Negative Figure 5 Power Supply Connections Page 14 of 70 ©Exertherm 2021 Global: +44 (0)1582 461123 USA: +1 646 512 5727 E: Sales@Exertherm.com MA-131-4-EN Exertherm® ARM XL Setup & Install Guide 7.3 RELAY OUTPUTS The ARM XL has 2 sets of relay outputs. These are located on the lower set of terminals on the expansion module on the rear of the ARM XL. Set 1 on terminals Y2, Y3, Y4, Y5 and set 2 on terminals Y6, Y7, Y8, Y9. Terminals COM1 & COM2 are common inputs for these relays. See Figure 6 Relay Outputs below. Figure 6 Relay Outputs These relays are all rated to 2Amp at 230v ac. These 2 sets of relays allow for both local and remote indication of alarms i.e. 1 set for local e.g. klaxon / flashing beacon, and the second for contact inputs to BMS or SCADA systems. Page 15 of 70 ©Exertherm 2021 Global: +44 (0)1582 461123 USA: +1 646 512 5727 E: Sales@Exertherm.com MA-131-4-EN Exertherm® ARM XL Setup & Install Guide 7.4 COMMUNICATION / CONNECTIVITY WITH EXERTHERM DEVICES The ARM XL allows for the connection of: • • 8ch Datacards - up to a maximum of 10 (80 Exertherm IR or Cable Sensors), and/or up to 60 MCC drawer/bucket MMDs via up to 5 MMAs (12 MMDs per MMA). Both the 8ch Datacard & the MMA connect to the ARM XL via a pre-manufactured cable (part no. 800445) which is supplied as part of the ARM XL. This cable has a maximum length of 3metres (10 feet) and should not be cut or extended. This cable has 2 connectors, 1 is an RJ45 for connecting to the port on the 8ch Datacard or MMA labelled ‘X0’ and the second is a DB9 male for connecting to the ARM XL’s port labelled ‘COM1’ as shown below in Figure 7. Figure 7 Communication to Exertherm Devices – RJ45 to COM1 All communication is set to operate at 9600 (9k6) baudrate only and cannot be adjusted. Page 16 of 70 ©Exertherm 2021 Global: +44 (0)1582 461123 USA: +1 646 512 5727 E: Sales@Exertherm.com MA-131-4-EN Exertherm® ARM XL Setup & Install Guide 7.4.1 EXERTHERM DEVICE NUMBERING 8ch Datacards MUST only be numbered from 10 through to 19, MUST be sequential and always start at 10. MMAs MUST be numbered from 20 through to 24, MUST be sequential and always start at 20. • There can be a maximum of 12 MMDs connected to any single MMA. The 12 MMDs can only be numbered 1 through to 12 and must be sequential and always start at 1. There can be no gaps in the numbering. E.g. if we have 4 of the 8ch Datacards in the setup we must use sequential numbering 10, 11, 12, 13 If 8ch Datacard numbers are not sequential, e.g. 10, 11, 13, 14 this will cause communication alarms on 8ch Datacards 13 & 14 (from where the numbering sequence is broken). E.g. if we have 3 MMAs in the setup we must use sequential numbering 20,21,22 If MMA numbers are not sequential, e.g. 20,21,23 this will cause communication alarms on the MMAs 23,24 (from where the numbering sequence is broken). 7.4.2 COMMUNICATION ALARMS The ARM XL constantly monitors the communication to each 8ch Datacard / MMA and if lost, will recheck this 3 times before reporting a failure. Once a failure of communication to any of the devices connected is detected, the relevant relays will energise and the Home View screen will identify which devices are in Comms alarm and the yellow ‘Alarm Reset’ button will appear at the bottom of the screen – e.g. the screen below shows a system with both 8ch Datacards & MMAs in fault, see Figure 8. This is reporting a communication fault on Card 10 and MMA 20. MMA 20 Page 17 of 70 MMA 21 MMA 22 MMA 23 MMA 24 ©Exertherm 2021 Global: +44 (0)1582 461123 USA: +1 646 512 5727 E: Sales@Exertherm.com MA-131-4-EN Exertherm® ARM XL Setup & Install Guide Figure 8 Communication Alarm Reason for Comms alarm: Network broken: • A broken network will affect the 8ch Datacards / MMAs at the breakpoint and all subsequent enabled devices in the numbered addressing sequence. o e.g. if Datacards 10, 11 & 12 and MMA 20 are enabled, and the network was broken at Datacard 11, the system would report a Comms Fault at the network break point Datacard 11. o It will then issue a Comms alarm for any enabled 8ch Datacards / MMAs past the break point following on in the numbered addressing sequence e.g. Card 12 & MMA 20 (see Figure 9 below). Figure 9 Comms alarm - Network Broken Power Failure: • • Lost power or power failure will only affect the 8ch Datacard / MMA that has power issues. Following example in Figure 9, e.g. if Datacard 11 lost power or failed and Datacard 12 was powered and connected, then only Datacard 11 would return a Comms Fault and Datacard 12 & MMA 20 would operate as normal. Each scan of the program will attempt to regain communication to any failed 8ch Datacards / MMAs until they are either repaired or disabled, at this point the Comms alarm can be reset by pressing the yellow ‘Alarm Reset’ button, the relays will then de-energise and clear. If an 8ch Datacard / MMA is enabled that does not exist, this will generate a Comms alarm. To reset, disable the 8ch Datacard / MMA: - For 8ch Datacard see Section 8.1.1 - For MMA see Section 8.1.2 - For both 8ch & MMA see Section 8.1.3 Page 18 of 70 ©Exertherm 2021 Global: +44 (0)1582 461123 USA: +1 646 512 5727 E: Sales@Exertherm.com MA-131-4-EN Exertherm® ARM XL Setup & Install Guide 8. CONFIGURATION AND SETUP The ARM XL is pre-configured with no programming tools or PLC knowledge required. There is a set of basic screen views which are described as follows: 8.1 INITIAL SETUP / CONFIGURATION On initial setup/configuration you do NOT need to be logged in to select the choice of hardware or to enable/disable devices. For first power up, the initial setup/configuration screen will appear. Figure 10 ARM XL Initial Setup/ Configuration This screen provides the user with the ability to select which hardware they wish the ARM XL to communicate with. There are 3 options to choose from: • • • 8ch Datacard only (this is the correct selection for Exertherm IR & Cable Sensors) MMA only (this is the correct selection for MCC drawer/bucket solution - MMDs) Both Pressing the selected hardware button from the 3 options above will take you to the relevant hardware Enabling / Disabling screen. Follow the relevant hardware enabling/disabling device instructions: • • • For 8ch Datacard see Section 8.1.1 For MMA see Section 8.1.2 For Both see Section 8.1.3 This main configuration screen also has a ‘Beep disable/enable’ button which mutes the touch screen sound. NOTE: As default, sound is disabled. Page 19 of 70 ©Exertherm 2021 Global: +44 (0)1582 461123 USA: +1 646 512 5727 E: Sales@Exertherm.com MA-131-4-EN Exertherm® ARM XL Setup & Install Guide NOTE: It is strongly recommended that prior to the ARM XL set up process, the physical location of each 8ch Datacard & Sensor and/or MMA & MMD is recorded as part of the configuration process. For 8ch Datacard - See Section 9.5 For MMA – See Section 10.4.2 Only enable 8ch Datacards / MMAs which have already been configured as part of the system commissioning process, and which are connected to the ARM XL. Do not enable 8ch Datacards or MMAs that are not connected, as this will cause false communication alarms. 8.1.1 ENABLING / DISABLING 8CH DATACARDS ONLY Return button Press to disable Datacard Press to enable Datacard Figure 11 Initial Setup / Config - Enabling/Disabling 8ch Datacards only On this screen, disabled 8ch Datacards will show with the Card number in a red button, and the button below in grey. To Enable communication from a 8ch Datacard to the ARM XL, press the grey button under the relevant Card number and both buttons will turn green as shown on Card 11 in Figure 11. To Disable communication from a 8ch Datacard to the ARM XL, press the green button under the relevant Card number. The Card number button will then turn red, and the button below will be grey. Once all required 8ch Datacards are enabled continue to the ‘Home / 8ch Datacard view’ screen by pressing the Return button in the top left corner of the screen. IMPORTANT: To operate the system, it is essential one 8ch Datacard is enabled. As 8ch Datacards must be enabled & addressed sequentially, it follows that ‘Card 10’ must always be enabled. Therefore, it is not shown on the above screen in Figure 11 so that it cannot be disabled. Page 20 of 70 ©Exertherm 2021 Global: +44 (0)1582 461123 USA: +1 646 512 5727 E: Sales@Exertherm.com MA-131-4-EN Exertherm® ARM XL Setup & Install Guide However, ‘Card 10’ will still show on the ‘Home / 8ch Datacard View’ screen so that Comms / Temperature alarms remain visible. 8.1.2 ENABLING / DISABLING MMA’S ONLY Return button Press to disable MMA Press to enable MMA Figure 12 Enabling / Disabling MMA only On this screen, disabled MMAs will show with the MMA number in a red button, and the button below in grey. To Enable communication from an MMA to the ARM XL, press the grey button under the relevant MMA number and both buttons will turn green as shown on MMA 20 in Figure 12 above. To Disable communication from a MMA to the ARM XL, press the green button under the relevant MMA number. The MMA number button will then turn red, and the button below will be grey. Once all required MMAs are enabled continue to the ‘Home / MMA view’ screen by pressing the Return button in the top left corner of the screen. IMPORTANT: All MMAs must be enabled & addressed sequentially, MMAs can only be numbered from 20 through to 24, and always start at 20. There can be a maximum of 12 MMDs connected to any single MMA. The 12 MMDs can only be numbered 1 through to 12 and must be sequential and always start at 1. Page 21 of 70 ©Exertherm 2021 Global: +44 (0)1582 461123 USA: +1 646 512 5727 E: Sales@Exertherm.com MA-131-4-EN Exertherm® ARM XL Setup & Install Guide 8.1.3 ENABLING / DISABLING BOTH 8CH DATACARDS & MMA’S On this screen, there is a choice of both 8ch Datacards & MMAs. Return button Press to disable Datacard Press to disable MMA Press to enable Datacard Press to enable MMA Figure 13 Enabling / Disabling both 8ch Datacards & MMAs 8ch Datacards To Enable communication from a 8ch Datacard to the ARM XL, press the grey button under the relevant Card number and both buttons will turn green as shown on Card 11 in Figure 13. To Disable communication from a Datacard to the ARM XL, press the green button under the relevant Card number. The Card number button will then turn red, and the button below will be grey. Once all required 8ch Datacards are enabled continue to the ‘Home / 8ch Datacard & MMA view’ screen by pressing the Return button in the top left corner of the screen. IMPORTANT - DATACARD: To operate the system, it is essential one 8ch Datacard is enabled. As 8ch Datacards must be enabled & addressed sequentially, it follows that ‘Card 10’ must always be enabled. Therefore, it is not shown on the above screen in Figure 13 so that it cannot be disabled. However, ‘Card 10’ will still show on the ‘Home / 8ch Datacard & MMA view’ screen so that Comms / Temperature alarms remain visible. MMAs To Enable communication from an MMA to the ARM XL, press the grey button under the relevant MMA number and both buttons will turn green as shown on MMA 20 in Figure 13. To Disable communication from a MMA to the ARM XL, press the green button under the relevant MMA number. The MMA number button will then turn red, and the button below will be grey. Once all required MMAs are enabled continue to the ‘Home / 8ch Datacard & MMA view’ screen by pressing the Return button in the top left corner of the screen. Page 22 of 70 ©Exertherm 2021 Global: +44 (0)1582 461123 USA: +1 646 512 5727 E: Sales@Exertherm.com MA-131-4-EN Exertherm® ARM XL Setup & Install Guide IMPORTANT - MMA: All MMAs must be enabled & addressed sequentially, MMAs can only be numbered from 20 through to 24, and always start at 20. There can be a maximum of 12 MMDs connected to any single MMA. The 12 MMDs can only be numbered 1 through to 12 and must be sequential and always start at 1. 8.2 CHANGING HARDWARE SELECTION If you wish to change and/or add to the main hardware selection: • • 8.2.1 a mistake has been made and you wish to change the hardware selection e.g. 8ch Datacard has been selected, when actually MMA should have been selected. OR you wish to add another hardware option to the existing hardware selected on the system e.g. existing system is 8ch Datacards only, and in addition you wish to add MMAs. CHANGING HARDWARE SELECTION PROCEDURE To make changes / additions to the hardware selection you must be logged in as a high-level user by following the below steps: 1. From the relevant hardware ‘Home’ screen, pressing the ‘Settings’ button in the lower left-hand corner of the screen will take you to the below screen, Figure 14. Figure 14 Settings - Initial Password Screen Page 23 of 70 ©Exertherm 2021 Global: +44 (0)1582 461123 USA: +1 646 512 5727 E: Sales@Exertherm.com MA-131-4-EN Exertherm® ARM XL Setup & Install Guide 2. From the screen shown in Figure 14 above, press the yellow star, a keypad will then appear 3. Using the numeric buttons on the keypad type in the password: 61123. 4. Then press the ‘ENT’ key – the following screen will appear Figure 15 Settings - Password Accepted Screen 5. Then press the green ‘OK’ button in Figure 15 above 6. You are now logged in as a high-level user. This will then show you the re-configuration version of the ‘Enable / Disable’ screen for the hardware originally selected 7. Press the ‘QHI’ button in the top right corner Page 24 of 70 ©Exertherm 2021 Global: +44 (0)1582 461123 USA: +1 646 512 5727 E: Sales@Exertherm.com MA-131-4-EN Exertherm® ARM XL Setup & Install Guide 8. This will then return you to the initial Setup/Configuration screen shown below where you can re-select the choice of hardware from the 3 options. 9. Then follow the relevant hardware enabling/disabling device instructions. • For 8ch Datacard see Section 8.1.1 • For MMA see Section 8.1.2 • For Both see Section 8.1.3 Page 25 of 70 ©Exertherm 2021 Global: +44 (0)1582 461123 USA: +1 646 512 5727 E: Sales@Exertherm.com MA-131-4-EN Exertherm® ARM XL Setup & Install Guide ONCE INITIAL SETUP / CONFIGURATION IS COMPLETE, PLEASE NOW CONTINUE TO THE RELEVANT SECTION TO FOLLOW VIEWING & USING INSTRUCTIONS FOR YOUR SELECTED HARDWARE USER GUIDE FOR 8CH DATACARD ONLY – PLEASE GO TO SECTION 9 USER GUIDE FOR MMA ONLY – PLEASE GO TO SECTION 10 USER GUIDE FOR BOTH 8CH DATACARD & MMA – PLEASE GO TO SECTION 11 Page 26 of 70 ©Exertherm 2021 Global: +44 (0)1582 461123 USA: +1 646 512 5727 E: Sales@Exertherm.com MA-131-4-EN Exertherm® ARM XL Setup & Install Guide 9. USER GUIDE– ARM XL & 8CH DATACARD ONLY 9.1 HOME / 8CH DATACARD VIEW SCREEN Once the system has been configured & required 8ch Datacards enabled, Figure 16 below will be the main user viewing screen. This screen will then appear whenever the ARM XL is powered up. The Home/ 8ch Datacard view screen shows the status of each 8ch Datacard, including alarms for temperature or communication for each 8ch Datacard enabled on the system. 8ch Datacards not enabled, will show as below e.g. Card 12. 8ch Datacards with no alarms will be displayed as ‘Healthy’ with a green button as shown below e.g. Card 10 & Card 11. Figure 16 Home / 8ch Datacard View Screen The ‘Alarm Reset’ button re-sets the alarm contacts when an alarm condition has been resolved. The ‘Alarm Reset’ button only appears when there is an active alarm condition. This button will be displayed centrally at the bottom of the screen. The ‘Settings’ button takes you to 8ch Datacard Enable / Disable screen (for more detail please see Section 8.1.1). The ‘Home / 8ch Datacard View’ screen also provides access to each enabled 8ch Datacard with realtime sensor values and warning alarms. From the Home / 8ch Datacard view screen, press the button for the 8ch Datacard you wish to view e.g. Card 10. The screen as shown in Figure 17 will appear. Page 27 of 70 ©Exertherm 2021 Global: +44 (0)1582 461123 USA: +1 646 512 5727 E: Sales@Exertherm.com MA-131-4-EN Exertherm® ARM XL Setup & Install Guide 9.1.1 SENSOR VIEW & WARNING ALARMS Sensor view: Down the left side are the sensor channels, which are numbered 1 t hrough 8. The next column indicates the real-time ΔT temperature values for each Sensor in °C. Sensor names e.g. Sensor 1, can be edited: • • • Channel Numbers • This is done by pressing on the Sensor name e.g. Sensor 1 A keypad will then appear (see Figure 18 below) Enter the unique Sensor name o Sensor names can include letters, numbers and symbols but can only be a maximum of 8 characters long e.g. CB2/A/L1 Once you have keyed in the new name, press ‘ENT’ to confirm name Figure 17 Sensor View & Warning Alarms Figure 18 8ch Datacard - Sensor name change keypad Page 28 of 70 ©Exertherm 2021 Global: +44 (0)1582 461123 USA: +1 646 512 5727 E: Sales@Exertherm.com MA-131-4-EN Exertherm® ARM XL Setup & Install Guide To change the Design and Maximum load values, you must be logged in as detailed in Section 9.2. Once logged in, return to the Datacard Home screen, and then select the Datacard which values are to be altered. Design and Max load values can be edited by: • • Pressing on the white box for the relevant Sensor number for either Design or Max Load A keypad will then appear • • Enter the required value Once you have keyed in the new value, press ‘ENT’ to confirm The column ‘Warning’ is the load related calculated ΔT alarm threshold from the LoadMap® algorithms. This field is not user adjustable but utilises the Design A & Max Load data to calculate this value. • • Design A – is the design load (Amps) of the circuit on which the joint being monitored resides and should be entered by clicking on the relevant box and entering the appropriate value in Amps. Max Load – is the maximum load at which the circuit being monitored is expected to operate at, and should be entered by clicking on the relevant box and entering the appropriate value in Amps. The Design A & Max Load values must be entered for each Sensor NOTE: If Load data for any sensor is unknown then a generic alarm threshold of ∆T 22°C can be set by entering in the Design A column a value of 800A and in the Max Load column a value of 600A. Press the ‘Return’ button in the top left corner of the screen to go back to the Home / 8ch Datacard View screen. Page 29 of 70 ©Exertherm 2021 Global: +44 (0)1582 461123 USA: +1 646 512 5727 E: Sales@Exertherm.com MA-131-4-EN Exertherm® ARM XL Setup & Install Guide 9.1.2 VIEWING WARNING ALARMS If a Sensor value exceeds the warning alarm threshold the Home / 8ch Datacard View screen view will change as in Figure 19 below. The status indicator below the Card number will change to show ‘Fault’ on a Red background. Figure 19 Datacard in alarm At the same time the ‘Alarm Reset’ button will appear at the bottom of the screen in Yellow with the word ‘Alarm Reset’ and the relevant relays will activate. All alarms are set with a 1 minute time delay to stop the system from ‘chattering’ and causing false alarms. A Sensor must be in an alarm state for over 1 minute for the relays to operate. To view the Sensor in alarm – press the red ‘Fault’ button below the Card number button which is in alarm. The Sensor View screen will appear as below in Figure 20. A yellow warning indicator box will be shown next to the Sensor in alarm. Figure 20 Sensor view - Sensor showing warning alarm Page 30 of 70 ©Exertherm 2021 Global: +44 (0)1582 461123 USA: +1 646 512 5727 E: Sales@Exertherm.com MA-131-4-EN Exertherm® ARM XL Setup & Install Guide When the alarm clears and the 8ch Datacard status returns to green & ‘Healthy’ both the output relays will remain energised until they are reset by pressing the yellow ‘Alarm Reset’ button on the Home / 8ch Datacard View screen as shown below in Figure 21. This will reset the relays and the ‘Alarm Reset’ button will disappear. Figure 21 Warning Alarm Reset Page 31 of 70 ©Exertherm 2021 Global: +44 (0)1582 461123 USA: +1 646 512 5727 E: Sales@Exertherm.com MA-131-4-EN Exertherm® ARM XL Setup & Install Guide 9.2 SYSTEM SETTINGS To access system settings you will need to login. This will allow you to access the following functions: • Enable / Disable 8ch Datacards • Set critical alarm level • Set TCP/IP settings 1. From the ‘Home / 8ch Datacard view’ screen, pressing the ‘Settings’ button in the lower lefthand corner will take you to the below screen. 2. From the screen shown above press the yellow star, a keypad will then appear 3. Using the numeric buttons on the keypad type in the password: 1582. 4. Then press the ‘ENT’ key – the following screen will appear 5. Then press the green ‘OK’ button Page 32 of 70 ©Exertherm 2021 Global: +44 (0)1582 461123 USA: +1 646 512 5727 E: Sales@Exertherm.com MA-131-4-EN Exertherm® ARM XL Setup & Install Guide 6. You are now logged in as a standard user. This will then show you the Settings version of the ‘8ch Datacard Enable / Disable’ screen as shown in Figure 22 in Section 9.2.1. 9.2.1 ENABLE / DISABLE 8CH DATACARDS First login as detailed in Section 9.2. Return button Press to enable datacard Press to disable datacard Figure 22 System Settings - Enabling/Disabling 8ch Datacards only On this screen, disabled 8ch Datacards will show with the Card number in a red button, and the button below in grey. To Enable communication from a 8ch Datacard to the ARM XL, press the grey button under the relevant Card number and both buttons will turn green as shown on Card 11 in Figure 22. To Disable communication from a 8ch Datacard to the ARM XL, press the green button under the relevant Card number. The Card number button will then turn red, and the button below will be grey. Once all required 8ch Datacards are enabled continue to the ‘Home / 8ch Datacard view’ screen by pressing the Return button in the top left corner of the screen. IMPORTANT: To operate the system, it is essential one 8ch Datacard is enabled. As 8ch Datacards must be enabled & addressed sequentially, it follows that ‘Card 10’ must always be enabled. Therefore, it is not shown on the above screen in Figure 22 so that it cannot be disabled. However, ‘Card 10’ will still show on the ‘Home / 8ch Datacard View’ screen so that Comms / Temperature alarms remain visible. Page 33 of 70 ©Exertherm 2021 Global: +44 (0)1582 461123 USA: +1 646 512 5727 E: Sales@Exertherm.com MA-131-4-EN Exertherm® ARM XL Setup & Install Guide 9.2.2 SET CRITICAL ALARM LEVEL First login as detailed in Section 9.2. The Critical alarm has a default threshold of Delta T (∆T) 40°C which applies to ALL sensors. It is user-configurable between ∆T 30-50°C. Figure 23 Setting Critical Alarm Level IMPORTANT: ALL temperature values are Delta T (∆T) °C e.g. rise of target temperature above the local ambient To edit the critical alarm level, press the alarm threshold value as circled above. The keypad as shown below will then appear: 30.00 • • • • Insert the new critical alarm threshold value required e.g. 30.00 and press the ‘ENT’ button you will then be returned to the ‘8ch Datacard Enable / Disable’ screen the new critical alarm threshold will now be applied to all Sensors connected to the ARM XL 30.00 Page 34 of 70 ©Exertherm 2021 Global: +44 (0)1582 461123 USA: +1 646 512 5727 E: Sales@Exertherm.com MA-131-4-EN Exertherm® ARM XL Setup & Install Guide 9.2.3 8CH DATACARD - SET TCP / IP SETTINGS First login as detailed in Section 9.2. 1. From the ‘8ch Datacard Enable / Disable’ screen press the ‘TCP/IP Setup’ button 2. The following address screen will appear (see Figure 24 below), the IP address is split into 4 separate segments. By touching the relevant segment of the IP address, the keypad will pop up and you can then enter the relevant portion of the IP address individually Figure 24 ARM XL TCP/IP Setting 3. Enter the Modbus TCP/IP address by first touching the relevant segment and then enter the relevant portion of the IP address. Existing settings are shown under heading ‘Current Setting’ as above. Page 35 of 70 ©Exertherm 2021 Global: +44 (0)1582 461123 USA: +1 646 512 5727 E: Sales@Exertherm.com MA-131-4-EN Exertherm® ARM XL Setup & Install Guide 4. As in the IP address below, an example address has been entered – 192.168.1.50 5. Repeat the same process for the Subnet Mask and IP Gateway. 6. The screen will then show as below (example addresses have also been entered for Subnet Mask & Default Gateway) 7. Once this information has been entered press the yellow ‘CONFIRM’ button that will then enter the information into system. 8. Then press the ‘return’ button in the bottom left hand corner to take you back to the ‘8ch Datacard Enable / Disable’ screen. Page 36 of 70 ©Exertherm 2021 Global: +44 (0)1582 461123 USA: +1 646 512 5727 E: Sales@Exertherm.com MA-131-4-EN Exertherm® ARM XL Setup & Install Guide 9.3 OBTAINING RAW DATA FROM THE ARM XL Raw data in Modbus TCP/IP protocol can be obtained from the ARM XL via the following actions: 1. Ensure TCP/IP settings have been entered as per instruction in 9.2.3 2. Then connect an Ethernet cable into the Port circled in red below on the rear of the ARM XL, as shown in Figure 25 . 3. Then connect the other end of the cable to a suitable host system connection point. The Modbus TCP uses standard Port 502 for communication and the ARM XL is set as device 1 Figure 25 ARM XL Ethernet Port To read the Sensor registers please refer to Table 1 in Section 9.4 which shows the Modbus holding registers. The registers require a 0.1 multiplier to read the correct value, e.g. if the register reads a raw data value of 150, then use 150 * 0.1 to read the correct register value of 15°C ∆T. Page 37 of 70 ©Exertherm 2021 Global: +44 (0)1582 461123 USA: +1 646 512 5727 E: Sales@Exertherm.com MA-131-4-EN Exertherm® ARM XL Setup & Install Guide 9.4 INTERNAL MODBUS TCP REGISTERS FOR 8CH DATACARD Sensor No. 1 2 3 4 5 6 7 8 Card No. TCP Register 10 10 10 10 10 10 10 10 40109 40110 40111 40112 40113 40114 40115 40116 11 11 11 11 11 11 11 11 40117 40118 40119 40120 40121 40122 40123 40124 12 12 12 12 12 12 12 12 40125 40126 40127 40128 40129 40130 40131 40132 13 13 13 13 13 13 13 13 40133 40134 40135 40136 40137 40138 40139 40140 14 14 14 14 14 14 14 14 40141 40142 40143 40144 40145 40146 40147 40148 15 15 15 15 15 15 15 15 40149 40150 40151 40152 40153 40154 40155 40156 16 16 16 16 16 16 16 16 40157 40158 40159 40160 40161 40162 40163 40164 17 17 17 17 17 17 17 17 40165 40166 40167 40168 40169 40170 40171 40172 18 18 18 18 18 18 18 18 40173 40174 40175 40176 40177 40178 40179 40180 19 19 19 19 19 19 19 19 40181 40182 40183 40184 40185 40186 40187 40188 Card No. TCP Register Card No. TCP Register Card No. TCP Register Card No. TCP Register Card No. TCP Register Card No. TCP Register Card No. TCP Register Card No. TCP Register Card No. TCP Register Table 1 Internal Modbus TCP Registers for 8ch Datacard Page 38 of 70 ©Exertherm 2021 Global: +44 (0)1582 461123 USA: +1 646 512 5727 E: Sales@Exertherm.com MA-131-4-EN Exertherm® ARM XL Setup & Install Guide 9.5 8CH DATACARD IO LIST Project Name: Customer: Section Ref: Modbus Address: Serial No.: DATACARD CHANNELS C H A N N E L C H A N N E L C H A N N E L C H A N N E L C H A N N E L C H A N N E L C H A N N E L C H A N N E L 1 2 3 4 5 6 7 8 Section Reference Phase Reference Sensor Type No Sensor IR.EM-06.SC – Delta T IR-01 Absolute Cable EM – Delta T Cable – Absolute IR.EM-06.SC Only Busbar Size Mounting Distance Gain Factor Used Factory Acceptance Test Initial Value Heat Tested Reading Datacard FAT: Accepted / Signed Installer: Date: Sign: Page 39 of 70 Client Rep. Date: Sign: ©Exertherm 2021 Global: +44 (0)1582 461123 USA: +1 646 512 5727 E: Sales@Exertherm.com MA-131-4-EN Exertherm® ARM XL Setup & Install Guide 10. USER GUIDE – ARM XL & MMA ONLY 10.1 HOME / MMA VIEW SCREEN Once the system has been configured & required MMA’s enabled, Figure 26 below will be the main user viewing screen. This screen will then appear whenever the ARM XL is powered up. The Home/MMA view screen shows the status of each MMA, including alarms for temperature or communication for each MMA enabled on the system. MMAs not enabled, will show as below e.g. MMA 21. MMAs with no alarms will be displayed as ‘Healthy’ with a green button as shown below e.g. MMA 20. Figure 26 Home / MMA View Screen The ‘Settings’ button takes you to MMA Enable / Disable screen. For more detail please see Section 8.1.2. The Home / MMA view screen also provides access to the status of each MMD on the system, this screen is accessed by pressing on the button below the card number for the relevant enabled MMA. Page 40 of 70 ©Exertherm 2021 Global: +44 (0)1582 461123 USA: +1 646 512 5727 E: Sales@Exertherm.com MA-131-4-EN Exertherm® ARM XL Setup & Install Guide 10.1.1 MMD STATUS SCREEN Once you have pressed the button of the MMA you wish to view, the following screen will appear – see below Figure 27. Only MMDs installed on the system will show with a green ‘healthy’ button as shown in MMDs 1-4 below. Any MMDs in alarm will show with a red ‘Fault’ button, as show in MMD 3 below. From the MMD View Screen press the ‘Healthy’ button for the MMD you wish to view e.g. MMD 1 which will take you to Figure 28 on the next page. Figure 27 MMD View Screen Pressing the ‘Fault’ button of the MMD in alarm will take you to Figure 29 (Section 10.1.2), which will signify which sensor is in alarm and in addition, identify the type of alarm. Page 41 of 70 ©Exertherm 2021 Global: +44 (0)1582 461123 USA: +1 646 512 5727 E: Sales@Exertherm.com MA-131-4-EN Exertherm® ARM XL Setup & Install Guide 10.1.2 MMD SENSOR VIEW & ALARMS Once you have pressed for the button of the MMD you wish to view as in Figure 27, the following screen will appear – see below Figure 28. Figure 28 MMD Sensor View & Alarms - Healthy Sensors are labelled: • L1 IN, L2 IN, L3 IN • L1 OUT, L2 OUT, L3 OUT The white boxes next to the sensor labels indicate the real-time temperature values for each sensor in °C. NOTE: These values are absolute temperature values At the bottom of the screen, it shows the four alarm types: • High Alarm • Sensor Fail Alarm • Delta T Alarm • Phase imbalance Alarm The small box next to each alarm type signifies the status e.g. • green = no alarm • red = active alarm Page 42 of 70 ©Exertherm 2021 Global: +44 (0)1582 461123 USA: +1 646 512 5727 E: Sales@Exertherm.com MA-131-4-EN Exertherm® ARM XL Setup & Install Guide This screen also indicates which sensor is in alarm, the name of the sensor will appear as circled in yellow in Figure 29. The type of alarm will be specified by the small box next to it turning red to indicate the active alarm e.g. as shown in Figure 29. NOTE: The location of which sensor is in alarm only shows for High alarm and Delta T Alarm. Figure 29 MMD Sensor View & Alarms - Active Alarm Alarms will only clear when they are re-set on the MMD itself. NOTE: No re-set for any MMD alarms can be carried out on the ARM XL. For instructions on how to re-set on the MMD, please see Section 9.4 of the MMS & MMA Installation Setup Manual. Press the ‘Return’ button in the top left corner of the screen to go back to the MMD status view (Figure 27 – Section 10.1.1). Page 43 of 70 ©Exertherm 2021 Global: +44 (0)1582 461123 USA: +1 646 512 5727 E: Sales@Exertherm.com MA-131-4-EN Exertherm® ARM XL Setup & Install Guide 10.2 SYSTEM SETTINGS To access system settings you will need to login. This will allow you to access the following functions: • Disable / Enable MMAs • Set TCP/IP settings 7. From the ‘Home / MMA view’ screen, pressing the ‘Settings’ button in the lower left-hand corner will take you to the below screen. 8. From the screen shown above press the yellow star, a keypad will then appear 9. Using the numeric buttons on the keypad type in the password: 1582. 10. Then press the ‘ENT’ key – the following screen will appear 11. Then press the green ‘OK’ button 12. You are now logged in as a standard user. This will then show you the Settings version of the ‘MMA Enable / Disable’ screen as shown in Figure 30 Section 10.2.1 on the following page. Page 44 of 70 ©Exertherm 2021 Global: +44 (0)1582 461123 USA: +1 646 512 5727 E: Sales@Exertherm.com MA-131-4-EN Exertherm® ARM XL Setup & Install Guide 10.2.1 ENABLE / DISABLE MMA First login as detailed in Section 10.2. Return button Press to disable 8ch Datacard Press to enable 8ch Datacard Figure 30 System Settings - Enabling/Disabling MMA only On this screen, disabled MMAs will show with the MMA number in a red button, and the button below in grey. To Enable communication from an MMA to the ARM XL, press the grey button under the relevant MMA number and both buttons will turn green as shown on MMA 20 in Figure 30 above. To Disable communication from a MMA to the ARM XL, press the green button under the relevant MMA number. The MMA number button will then turn red, and the button below will be grey. Once all required MMAs are enabled continue to the ‘Home / MMA view’ screen by pressing the Return button in the top left corner of the screen. IMPORTANT: All MMAs must be enabled & addressed sequentially, MMAs can only be numbered from 20 through to 24, and always start at 20. There can be a maximum of 12 MMDs connected to any single MMA. The 12 MMDs can only be numbered 1 through to 12 and must be sequential and always start at 1. Page 45 of 70 ©Exertherm 2021 Global: +44 (0)1582 461123 USA: +1 646 512 5727 E: Sales@Exertherm.com MA-131-4-EN Exertherm® ARM XL Setup & Install Guide 10.2.2 MMA – SET TCP / IP SETTINGS First login as detailed in Section 10.2 9. From the ‘MMA Enable / Disable’ screen press the ‘TCP/IP Setup’ button 10. The following address screen will appear (see Figure 31Figure 24 below), the IP address is split into 4 separate segments. By touching the relevant segment of the IP address, the keypad will pop up and you can then enter the relevant portion of the IP address individually Figure 31 ARM XL TCP/IP Setting 11. Enter the Modbus TCP/IP address by first touching the relevant segment and then enter the relevant portion of the IP address. Existing settings are shown under heading ‘Current Setting’ as above. Page 46 of 70 ©Exertherm 2021 Global: +44 (0)1582 461123 USA: +1 646 512 5727 E: Sales@Exertherm.com MA-131-4-EN Exertherm® ARM XL Setup & Install Guide 12. As in the IP address below, an example address has been entered – 192.168.1.50 13. Repeat the same process for the Subnet Mask and IP Gateway. 14. The screen will then show as below (example addresses have also been entered for Subnet Mask & Default Gateway) 15. Once this information has been entered press the yellow ‘CONFIRM’ button that will then enter the information into system. 16. Then press the ‘return’ button in the bottom left hand corner to take you back to the ‘MMA Enable / Disable’ screen. Page 47 of 70 ©Exertherm 2021 Global: +44 (0)1582 461123 USA: +1 646 512 5727 E: Sales@Exertherm.com MA-131-4-EN Exertherm® ARM XL Setup & Install Guide 10.3 OBTAINING RAW DATA FROM THE ARM XL Raw data in Modbus TCP/IP protocol can be obtained from the ARM XL via the following actions: 1. 2. 3. Ensure TCP/IP settings have been entered as per instruction in 10.2.2 Then connect an Ethernet cable into the Port circled in red below on the rear of the ARM XL, as shown in Figure 32 below. Then connect the other end of the cable to a suitable host system connection point. The Modbus TCP uses standard Port 502 for communication and the ARM XL is set as device 1 Figure 32 ARM XL TCP/IP Port To read the Sensor registers please refer to the relevant tables within Section 10.4 on the following page which shows the Modbus holding registers. The registers require a 0.1 multiplier to read the correct value, e.g. if the register reads a raw data value of 150, then use 150 * 0.1 to read the correct register value of 15°C ∆T. Page 48 of 70 ©Exertherm 2021 Global: +44 (0)1582 461123 USA: +1 646 512 5727 E: Sales@Exertherm.com MA-131-4-EN Exertherm® ARM XL Setup & Install Guide 10.4 INTERNAL MODBUS TCP REGISTERS FOR MMA 10.4.1 INTERNAL MODBUS TCP REGISTERS FOR MMA 20 Sensor No. L1 IN L2 IN L3 IN L1 OUT L2 OUT L3 OUT MMD 1 TCP Register 453501 453502 453503 453504 453505 453506 MMD 2 TCP Register 453507 453508 453509 453510 453511 453512 MMD 3 TCP Register 453513 453514 453515 453516 453517 453518 MMD 4 TCP Register 453519 453520 453521 453522 453523 453524 MMD 5 TCP Register 453525 453526 453527 453528 453529 453530 MMD 6 TCP Register 453531 453532 453533 453534 453535 453536 MMD 7 TCP Register 453537 453538 453539 453540 453541 453542 MMD 8 TCP Register 453543 453544 453545 453546 453547 453548 MMD 9 TCP Register 453549 453550 453551 453552 453553 453554 MMD 10 TCP Register 453555 453556 453557 453558 453559 453560 MMD 11 TCP Register 453561 453562 453563 453564 453565 453566 MMD 12 TCP Register 453567 453568 453569 453570 453571 453572 Table 2 Internal Modbus TCP Registers for MMA 20 Page 49 of 70 ©Exertherm 2021 Global: +44 (0)1582 461123 USA: +1 646 512 5727 E: Sales@Exertherm.com MA-131-4-EN Exertherm® ARM XL Setup & Install Guide 10.4.2 INTERNAL MODBUS TCP REGISTERS FOR MMA 21 Sensor No. L1 IN L2 IN L3 IN L1 OUT L2 OUT L3 OUT MMD 1 TCP Register 453573 453574 453575 453576 453577 453578 MMD 2 TCP Register 453579 453580 453581 453582 453583 453584 MMD 3 TCP Register 453585 453586 453587 453588 453589 453590 MMD 4 TCP Register 453591 453592 453593 453594 453595 453596 MMD 5 TCP Register 453597 453598 453599 453600 453601 453602 MMD 6 TCP Register 453603 453604 453605 453606 453607 453608 MMD 7 TCP Register 453609 453610 453611 453612 453613 453614 MMD 8 TCP Register 453615 453616 453617 453618 453619 453620 MMD 9 TCP Register 453621 453622 453623 453624 453625 453626 MMD 10 TCP Register 453627 453628 453629 453630 453631 453632 MMD 11 TCP Register 453633 453634 453635 453636 453637 453638 MMD 12 TCP Register 453639 453640 453641 453642 453643 453644 Table 3 Internal Modbus TCP Registers for MMA 21 Page 50 of 70 ©Exertherm 2021 Global: +44 (0)1582 461123 USA: +1 646 512 5727 E: Sales@Exertherm.com MA-131-4-EN Exertherm® ARM XL Setup & Install Guide 10.4.3 INTERNAL MODBUS TCP REGISTERS FOR MMA 22 Sensor No. L1 IN L2 IN L3 IN L1 OUT L2 OUT L3 OUT MMD 1 TCP Register 453645 453646 453647 453648 453649 453650 MMD 2 TCP Register 453651 453652 453653 453654 453655 453656 MMD 3 TCP Register 453657 453658 453659 453660 453661 453662 MMD 4 TCP Register 453663 453664 453665 453666 453667 453668 MMD 5 TCP Register 453669 453670 453671 453672 453673 453674 MMD 6 TCP Register 453675 453676 453677 453678 453679 453680 MMD 7 TCP Register 453681 453682 453683 453684 453685 453686 MMD 8 TCP Register 453687 453688 453689 453690 453691 453692 MMD 9 TCP Register 453693 453694 453695 453696 453697 453698 MMD 10 TCP Register 453699 453700 453701 453702 453703 453704 MMD 11 TCP Register 453705 453706 453707 453708 453709 453710 MMD 12 TCP Register 453711 453712 453713 453714 453715 453716 Table 4 Internal Modbus TCP Registers for MMA 22 Page 51 of 70 ©Exertherm 2021 Global: +44 (0)1582 461123 USA: +1 646 512 5727 E: Sales@Exertherm.com MA-131-4-EN Exertherm® ARM XL Setup & Install Guide 10.4.4 INTERNAL MODBUS TCP REGISTERS FOR MMA 23 Sensor No. L1 IN L2 IN L3 IN L1 OUT L2 OUT L3 OUT MMD 1 TCP Register 453717 453718 453719 453720 453721 453722 MMD 2 TCP Register 453723 453724 453725 453726 453727 453728 MMD 3 TCP Register 453729 453730 453731 453732 453733 453734 MMD 4 TCP Register 453735 453736 453737 453738 453739 453740 MMD 5 TCP Register 453741 453742 453743 453744 453745 453746 MMD 6 TCP Register 453747 453748 453749 453750 453751 453752 MMD 7 TCP Register 453753 453754 453755 453756 453757 453758 MMD 8 TCP Register 453759 453760 453761 453762 453763 453764 MMD 9 TCP Register 453765 453766 453767 453768 453769 453770 MMD 10 TCP Register 453771 453772 453773 453774 453775 453776 MMD 11 TCP Register 453777 453778 453779 453780 453781 453782 MMD 12 TCP Register 453783 453784 453785 453786 453787 453788 Table 5 Internal Modbus TCP Registers for MMA 23 Page 52 of 70 ©Exertherm 2021 Global: +44 (0)1582 461123 USA: +1 646 512 5727 E: Sales@Exertherm.com MA-131-4-EN Exertherm® ARM XL Setup & Install Guide 10.4.5 INTERNAL MODBUS TCP REGISTERS FOR MMA 24 Sensor No. L1 IN L2 IN L3 IN L1 OUT L2 OUT L3 OUT MMD 1 TCP Register 453789 453790 453791 453792 453793 453794 MMD 2 TCP Register 453795 453796 453797 453798 453799 453800 MMD 3 TCP Register 453801 453802 453803 453804 453805 453806 MMD 4 TCP Register 453807 453808 453809 453810 453811 453812 MMD 5 TCP Register 453813 453814 453815 453816 453817 453818 MMD 6 TCP Register 453819 453820 453821 453822 453823 453824 MMD 7 TCP Register 453825 453826 453827 453828 453829 453830 MMD 8 TCP Register 453831 453832 453833 453834 453835 453836 MMD 9 TCP Register 453837 453838 453839 453840 453841 453842 MMD 10 TCP Register 453843 453844 453845 453846 453847 453848 MMD 11 TCP Register 453849 453850 453851 453852 453853 453854 MMD 12 TCP Register 453855 453856 453857 453858 453859 453860 Table 6 Internal Modbus TCP Registers for MMA 24 EXERTHERM TEMP/HUMIDITY SENSOR: Temperature & humidity can also be read via registers Temperature 453861 Humidity 453862 Page 53 of 70 ©Exertherm 2021 Global: +44 (0)1582 461123 USA: +1 646 512 5727 E: Sales@Exertherm.com MA-131-4-EN Exertherm® ARM XL Setup & Install Guide 10.5 MMA IO LIST Project Name: Customer: Description Revision No. Page No. MMA No. Switchgear Section: Phase Reference: Switchgear Section: L1IN L2IN L3IN L1OUT L2OUT L3OUT Phase Reference: Switchgear Section: L1IN L2IN L3IN L1OUT L2OUT L3OUT Phase Reference: Installer: Page 54 of 70 Description: Sensor Card Type: Address: Description: RTD RTD RTD RTD RTD RTD Sensor Card Type: Address: Description: RTD RTD RTD RTD RTD RTD Sensor Card Type: Address: Input: L1IN RTD L1IN L2IN RTD L2IN L3IN RTD L3IN L1OUT RTD L1OUT L2OUT RTD L2OUT L3OUT RTD L3OUT Date: Sign: Client Rep: Date: ©Exertherm 2021 Global: +44 (0)1582 461123 USA: +1 646 512 5727 E: Sales@Exertherm.com Input: L1IN L2IN L3IN L1OUT L2OUT L3OUT Input: L1IN L2IN L3IN L1OUT L2OUT L3OUT Sign: MA-131-4-EN Exertherm® ARM XL Setup & Install Guide 11. USER GUIDE – ARM XL WITH BOTH 8CH DATACARD + MMA 11.1 HOME / 8CH DATACARD & MMA VIEW SCREEN Once the system has been configured & required 8ch Datacards & MMAs have been enabled, Figure 33 below will be the main user viewing screen. This screen will then appear whenever the ARML XL is powered up. The Home / 8ch Datacard & MMA view screen shows the status of each enabled device, including alarms for temperature or communication. 8ch Datacards: • • • 8ch Datacards not enabled, will show was below e.g. Card 12 8ch Datacards with no alarms will be displayed as ‘Healthy’ with a green button as shown below e.g. Card 10. 8ch Datacards with alarms with be displayed as ‘Fault’ with a red button as shown below e.g. Card 11 MMAs: • • • MMAs not enabled, will show was below e.g. MMA 22 MMAs with no alarms will be displayed as ‘Healthy’ with a green button as shown below e.g. MMA 20. MMAs with alarms with be displayed as ‘Fault’ with a red button as shown below e.g. MMA 21 20 21 22 23 24 2 3 2 2 Figure 33 Home / 8ch Datacard & MMA View Screen The ‘Settings’ button takes you to the 8ch Datacard & MMA Enable/Disable screen. For more detail please see Section 8.1.3. Page 55 of 70 ©Exertherm 2021 Global: +44 (0)1582 461123 USA: +1 646 512 5727 E: Sales@Exertherm.com MA-131-4-EN Exertherm® ARM XL Setup & Install Guide 11.1.1 8CH DATACARD & MMA STATUS SCREEN The Home / 8ch Datacard & MMA view screen also provides access to each enabled device with realtime sensor values and warning alarms. Datacards From the Home / 8ch Datacard & MMA view screen, press the button for the 8ch Datacard you wish to view e.g. Card 10. For further instructions please refer to Section 9 User Guide– ARM XL & 8ch Datacard Only. PLEASE NOTE: Although the screen on the ARM XL Although screens shown in Section 9 only show 8ch Datacards, the screens will show both 8ch Datacards & MMAs – the functionality and instructions remain exactly the same. MMAs From the Home / 8ch Datacard & MMA view screen, press the button for the MMA you wish to view e.g. MMA 20. For further instructions please refer to Section 10 User Guide – ARM XL & MMA Only. PLEASE NOTE: Although screens shown in Section 9 only show MMAs, the screens you see will show both 8ch Datacards & MMAs – the functionality and instructions remain exactly the same. Page 56 of 70 ©Exertherm 2021 Global: +44 (0)1582 461123 USA: +1 646 512 5727 E: Sales@Exertherm.com MA-131-4-EN Exertherm® ARM XL Setup & Install Guide 12. USER GUIDE – ADDITION OF EXERTHERM TEMP / HUMIDITY SENSOR TO ARM XL 12.1 INSTALLING THE EXERTHERM TEMP / HUMIDITY SENSOR To mount the Exertherm Temp/Humidity Sensor (Part # 800457): 1. 2. 3. 4. 5. 6. 7. 8. 12.2 Select a location which will give a representative sample of the space within the switchgear, respecting all relevant clearance distances Fix the Exertherm Temp/Humidity Sensor housing to the panel, screw hole centres are 92mm or 3 5/8” Release the snap fit lid by gently squeezing the locking tab Ensure the ARM XL and Exertherm Temp/Humidity sensor are supplied by the SAME 24v dc power supply. Feed the cable (4 cores, max 0.75mm² 20AWG) through the dustproof gland and terminate the cores on the Exertherm Temp/Humidity Sensors terminal block, respecting polarity and connections The Yellow Dip switches should be correctly set as default, please check to ensure they are in the correct position as per the diagram in Figure 35 on the following page. Ensure the supply voltage is within correct tolerance of 24v dc ± 2v dc Once powered, the Exertherm Temp/Humidity Sensor will take approx. 30 mins to stabilise to the correct humidity (this is normal). EXERTHERM TEMP/HUMIDITY SENSOR WIRING DIAGRAM Figure 34 Exertherm Temp/Humidity Sensor to ARM XL Wiring Diagram Page 57 of 70 ©Exertherm 2021 Global: +44 (0)1582 461123 USA: +1 646 512 5727 E: Sales@Exertherm.com MA-131-4-EN Exertherm® ARM XL Setup & Install Guide 12.3 INTERNAL DEFAULT SETTINGS FOR EXERTHERM TEMP/HUMIDITY SENSOR The Yellow Dip switches as factory default should be set as below, please check to ensure they are in the correct position as per Figure 35. Humidity Sensor Figure 35 Default Settings & Connections for Exertherm Temp/Humidity Sensor Page 58 of 70 ©Exertherm 2021 Global: +44 (0)1582 461123 USA: +1 646 512 5727 E: Sales@Exertherm.com MA-131-4-EN Exertherm® ARM XL Setup & Install Guide 12.4 HOME VIEW SCREEN This screen is only active when an Exertherm Temp/Humidity Sensor is connected to the ARM XL, the ‘Temp/Humidity’ button will then appear on the Home Screen (see Figure 36). If no Exertherm Temp/Humidity Sensor is connected, then no ‘Temp/Humidity’ button will appear. Figure 36 Home Screen showing Exertherm Temp / Humidity Sensor Enabled When the ‘Temp/Humidity’ button is visible (as shown above), the Exertherm Temp/Humidity Sensor is then operational. Page 59 of 70 ©Exertherm 2021 Global: +44 (0)1582 461123 USA: +1 646 512 5727 E: Sales@Exertherm.com MA-131-4-EN Exertherm® ARM XL Setup & Install Guide 12.5 EXERTHERM TEMP/HUMIDITY SENSOR VALUES & ALARMS Pressing on the ‘Temp/Humidity’ button from the Home screen will then illustrate the current Exertherm Temp/Humidity Sensor values and alarm setpoints (see below Figure 37). The alarm setpoints can be adjusted by pressing on the alarm value, a keypad will then appears where you can type in the required alarm setpoint. Press enter to acknowledge the new alarm setpoint. Figure 37 Exertherm Temp / Humidity Sensor Values & Alarms When the Exertherm Temp/Humidity Sensor is in alarm, the ‘Temp/Humidity’ button on the Home Screen will have a red border as shown here. 12.6 EXERTHERM TEMP /HUMIDITY SENSOR ALARMS WIRING DIAGRAM Alarm contacts Y10 and Y11 will operate to signify that an alarm condition has been detected i.e. a high temperature or high humidity from the Exertherm Temp/Humidity Sensor. The ‘Temp / Humidity’ button on the home screen will also have a Red border around it, as described above in Section 12.5. NOTE: For Exertherm Temp / Humidity Sensor registers please see Section 10.4.5 Figure 38 Exertherm Temp / Humidity Sensor Alarms Wiring Diagram Page 60 of 70 ©Exertherm 2021 Global: +44 (0)1582 461123 USA: +1 646 512 5727 E: Sales@Exertherm.com MA-131-4-EN Exertherm® ARM XL Setup & Install Guide 12.7 EXERTHERM TEMPERATURE / HUMIDITY SENSOR DATASHEET Page 61 of 70 ©Exertherm 2021 Global: +44 (0)1582 461123 USA: +1 646 512 5727 E: Sales@Exertherm.com MA-131-4-EN Exertherm® ARM XL Setup & Install Guide Page 62 of 70 ©Exertherm 2021 Global: +44 (0)1582 461123 USA: +1 646 512 5727 E: Sales@Exertherm.com MA-131-4-EN Exertherm® ARM XL Setup & Install Guide Page 63 of 70 ©Exertherm 2021 Global: +44 (0)1582 461123 USA: +1 646 512 5727 E: Sales@Exertherm.com MA-131-4-EN Exertherm® ARM XL Setup & Install Guide 13. UPGRADING ARM XL SOFTWARE 13.1 GETTING STARTED To begin upgrading the ARM XL Software, you will need a USB memory stick loaded with the latest version of the Software. Software will be supplied by Exertherm, memory stick must be 4gb or less. 1. Please follow Login instructions detailed in Section 8.2.1 2. When you are then on the relevant hardware’s Enable / Disable screen, press the QHI button in the top right hand corner 3. The screen as below will then appear as in Figure 39 4. This screen also shows the current version of the Software in the top left hand corner e.g. V1.08.18.005 Figure 39 Software Upgrade - ARM XL Setup Screen Page 64 of 70 ©Exertherm 2021 Global: +44 (0)1582 461123 USA: +1 646 512 5727 E: Sales@Exertherm.com MA-131-4-EN Exertherm® ARM XL Setup & Install Guide 13.2 ARM XL UPGRADE PROCESS 1. Please insert the USB memory stick into the ‘Host’ port on the reverse of the ARM XL 2. Press the ‘Load New Software’ button as shown on Figure 39 above. 3. You will then see the following screen – press ‘Yes’ If you do not press anything the ARM XL will time out and re-start. If you press ‘No’ the ARM XL will automatically re-start. 4. Once you have pressed ‘Yes’ the below screen will appear. Press the ‘Download’ button. IMPORTANT: DO NOT PRESS THE ‘UPLOAD’ BUTTON OR THE USB MEMORY STICK WILL BE OVERWRITTEN Page 65 of 70 ©Exertherm 2021 Global: +44 (0)1582 461123 USA: +1 646 512 5727 E: Sales@Exertherm.com MA-131-4-EN Exertherm® ARM XL Setup & Install Guide 5. The below screen will then appear, you must then select the ‘Application’ and ‘Logic’ boxes only – once selected the boxes will turn green as shown below. Then press the ‘Download’ button. IMPORTANT: Do NOT select any other options 6. This will take you to the following screen, press ‘OK’. Page 66 of 70 ©Exertherm 2021 Global: +44 (0)1582 461123 USA: +1 646 512 5727 E: Sales@Exertherm.com MA-131-4-EN Exertherm® ARM XL Setup & Install Guide 7. While the Software is downloading you will see the below progress bar screen. IMPORTANT: Do NOT unplug the memory stick and do not unplug the ARM XL at any time during the upgrade process. 8. The following screen will then appear when the download has completed successfully. Then press ‘OK’. Page 67 of 70 ©Exertherm 2021 Global: +44 (0)1582 461123 USA: +1 646 512 5727 E: Sales@Exertherm.com MA-131-4-EN Exertherm® ARM XL Setup & Install Guide 9. The below screen will then appear. Now remove the USB memory stick and then press ‘Exit’. 10. The ARM XL will then automatically re-start with the new version of Software. Page 68 of 70 ©Exertherm 2021 Global: +44 (0)1582 461123 USA: +1 646 512 5727 E: Sales@Exertherm.com MA-131-4-EN Exertherm® ARM XL Setup & Install Guide 14. ARM XL DATASHEET Page 69 of 70 ©Exertherm 2021 Global: +44 (0)1582 461123 USA: +1 646 512 5727 E: Sales@Exertherm.com MA-131-4-EN Exertherm® ARM XL Setup & Install Guide Page 70 of 70 ©Exertherm 2021 Global: +44 (0)1582 461123 USA: +1 646 512 5727 E: Sales@Exertherm.com MA-131-4-EN
0
You can add this document to your study collection(s)
Sign in Available only to authorized usersYou can add this document to your saved list
Sign in Available only to authorized users(For complaints, use another form )