A Practical Guide for Medical Equipment and Electrical System Testing According to International Standard: IEC 62353: Medical electrical equipment – Recurrent test and test after repair of medical electrical equipment www.metrel.si Introduction Medical equipment testing is another sub-field of PAT testing, but one that requires special care since the tested devices are in direct contact with medical staff and patients, which translates to a heightened probability of electric shock. There are numerous types of medical equipment that needs to be regularly inspected and tested to maintain its reliability. Metrel has developed a special version of MI 3360 OmegaPAT XA (model M), which covers the international standard IEC/EN 62353 for medical electrical equipment testing. This guide covers a basic introduction to electrical safety, basic definitions of a medical equipment (ME) and an overview of the IEC 62353 standard. The test diagrams presented in this booklet are designed as a guideline for people involved in testing of medical electrical equipment with the OmegaPAT XA MI 3360M. The guide itself cannot replace the standard IEC 62353 which was used as a reference for preparation of this booklet. For clarification on any part of this guide, contact Metrel d.d. Page 2 Table of contents Classification of equipment (by protection classes) 4 Typical parts of a medical equipment 5 1. Visual check (Class I, II, III) 6 2. Earth bond (Class I) 7 3. Insulation resistance (Class I, II) 8-9 4. Leakage currents10 4.1 Measurement of equipment leakage current 11 4.1.1 Alternative method (Equipment leakage) 11 4.1.2 Direct method (Equipment leakage) 12 4.1.3 Differential method (Equipment leakage) 13 4.2 Measurement of applied part leakage current 14 4.2.1 Alternative method (Applied part) 15 4.2.2 Direct method (Applied part) 16 4.3 Measurement of touch leakage current Sequence of testing Sequence for selection of appropriate leakage current 17 18 19 AUTO SEQUENCE® 20 - 22 Professional reporting 23 Page 3 Classification of equipment (by protection classes) CLASSIFICATION OF EQUIPMENT (BY PROTECTION CLASSES) Class I Marking No Supply cord Three pole (L, N, PE) II III III Two pole, L, N Two pole Examples CLASSIFICATION OF EQUIPMENT (BY PROTECTION CLASSES) Type B B-body Description Equipment with applied part(s) not isolated from power supply and enclosure. BF F-floating Equipment with applied part(s) isolated from power supply and enclosure. Higher protection degree. CF C-cardiac Equipment intended for cardiac applications on the patient, is isolated from power supply and enclosure. Highest protection degree. Page 4 Mark A Practical Guide for Medical Equipment and Electrical System Testing Typical parts of a medical equipment Typical parts of medical equipment that are relevant for electrical safety are shown on the picture below: Accessible conductive part A part of medical equipment other than applied part that can come in contact with the patient. Applied part An applied part is a probe or other part of equipment that necessarily comes into physical contact with the patient for the medical equipment to perform its function. Applied part of TYPE-CF provides a higher degree of protection against electric shock than parts of TYPE-B and BF. Mains part Electronic circuit that is connected to the supply mains. The mains part includes all conductive parts that are not separated from the supply mains by at least one means of protection. 1. Mains part 2. L,N,PE conductors (supply cord) 3. Accessible metal part 4. Enclosure 5. Applied part of TYPE-B 6. Applied part of TYPE-F (BF, CF) Page 5 1. Visual check (Class I, II, III) Items that we should pay special attention to: • Safety related markings, labels and labelling have to be legible and complete; • The integrity of mechanical parts; • Any damage or contamination e.g. any evidence of spillage; • Assess the relevant ACCESSORIES together with the ME EQUIPMENT or ME SYSTEM (e.g. detachable or fixed POWER SUPPLY CORDS, patient leads, tubing); • The required documentation is available and reflects the current revision and/or CONFIGURATION of the ME EQUIPMENT or ME SYSTEM; • All fuses accessible from the outside are compliant with the data given by the manufacturer; • After testing, REPAIR or adjustment, check that the ME EQUIPMENT or ME SYSTEM is restored to the conditions necessary for intended use before being returned into service. Figure 1 (Visual inspection - IEC/EN 62353) Page 6 A Practical Guide for Medical Equipment and Electrical System Testing 2. Earth bond (Class I) Measurements shall be performed using a measuring device able to deliver a current of at least 200 mA into 500 mΩ. The open circuit voltage shall not exceed 24 V.Low current tests (up to 1 A) are recommended, as they can disclose bad contacts. Note 1: For large cross section areas and shorter conductor lengths, higher test currents for the continuity test improve the repeatability of the test results. Type Description ME equipment or an ME system with non-detachable power supply cord - Figure 2 ME equipment or an ME system with detachable power supply cord - Figure 2 < 300 mΩ Permanently installed ME equipment - Figure 3 < 300 mΩ ME system with a multiple socket-outlet TN system without RCD < 300 mΩ Installed RCD or IT system < 500 mΩ Table 1 Figure 2 (Protective earth resistance, Class I) ME equipment or system only < 200 mΩ Supply cord only < 100 mΩ Complete system with supply cord < 300 mΩ Figure 3 (Protective earth resistance, Class I, permanently installed) Page 7 3. Insulation resistance (Class I, II) If there is any doubt about the insulation of ME equipment, the insulation resistance measurement shall be considered in addition to the leakage current measurement. Measurements of the insulation resistance shall be performed with a test voltage of 500 V (D.C.). Test voltage not lower than 250 V D.C. may be used if overvoltage protective devices are included in the test configuration. Test equipment shall be disconnected from mains and all switches shall be in operating position (ON). Keep in mind that insulation resistance test is not mandatory! Minimum insulation resistance for ME equipment Between mains part and protective earth for Class I ME equipment - Figure 4 Class I Class II ≥ 2 MΩ - Between mains part and (non-earthed) accessible conductive ≥ 7 MΩ ≥ 7 MΩ parts for Class II ME equipment (optional Class I) - Figure 5 Between mains part and applied part TYPE-B which make ≥ 2 MΩ ≥ 7 MΩ a patient connection and protective earth Class II ME equipment (optional Class I) - Figure 7 Between mains part and applied part TYPE-F which make a ≥ 70 MΩ ≥ 70 MΩ patient connection and protective earth Class II ME equipment (optional Class I) - Figure 7 Between TYPE-F applied parts which make a patient ≥ 70 MΩ ≥ 70 MΩ connection and protective earth for Class I or Class II ME equipment - Figure 6, 8 Table 2 Figure 4 (Insulation resistance, Class I) Page 8 A Practical Guide for Medical Equipment and Electrical System Testing 3. Insulation resistance (Class I, II) Measuring conditions for insulation measurement between mains parts and applied parts: - all applied parts TYPE-B shall be connected together during test - all applied parts TYPE-F shall be connected together during test Figure 5 (Insulation resistance, Class II) Figure 6 (Insulation resistance, Isolated metal housing against TYPE-F applied parts, Class I, II) Figure 7 (Insulation resistance, Mains part against applied parts, Class I, II) Figure 8 (Insulation resistance, Protective earth against TYPE-F applied parts, Class I) Page 9 4. Leakage currents Depending on the ME EQUIPMENT or ME SYSTEM one of the following methods of measuring the EQUIPMENT LEAKAGE CURRENTS or the APPLIED PART LEAKAGE CURRENT may be used: a) Alternative method, b) Direct method, c) Differential method, d) Alternatively, touch method or patient method derived from IEC 60601-1 may be used. Equipment under testing shall be measured in the operating conditions. Current Equipment leakage current – alternative method for accessible conductive parts of Class I ME equipment - Figure 9 for accessible conductive parts of Class II ME equipment - Figure 10 Equipment leakage current – direct or differential method for accessible conductive parts of Class I ME equipment - Figure 11, 13 for accessible conductive parts of Class II ME equipment - Figure 12, 14 Touch current (according to IEC 60601-1) for accessible conductive parts Applied part leakage current – alternative method (A.C.) according to Figure 15, 16 Applied part leakage current – direct method (A.C.) according to Figure 17, 18, 19 TYPE-B TYPE-BF TYPE-CF 1000 µA 500 µA 1000 µA 500 µA 1000 µA 500 µA 500 µA 100 µA 500 µA 100 µA 500 µA 100 µA 100 µA 100 µA 100 µA 5000 µA 50 µA 5000 µA 50 µA Table 3 Note 1: This table does not provide allowable values for equipment producing D.C. leakage currents. Note 2: Certain standards can allow different values of leakage current. For example: Defibrillation paddles, TYPE-CF: Leakage current from applied part: 100 µA Mobile x-ray generators, equipment leakage current, alternative method: 5000 µA, direct or differential method: 2000 µA Page 10 A Practical Guide for Medical Equipment and Electrical System Testing 4. Leakage currents 4.1 Measurement of equipment leakage current This measurement is not applicable for equipment with an internal electrical power source. 4.1.1 Alternative method (Equipment leakage) ME Equipment is separated from mains and the equipment leakage current is measured according to Figure 9, 10. Note 1: Class I ME does not need to be isolated from PE during measurement. Note 2: If the leakage current exceeds 1 mA, either direct or touch measurement shall be applied (allowable values in Table 3). Figure 9 (Equipment leakage, Alternative, Class I) Figure 10 (Equipment leakage, Alternative, Class II) Page 11 4. Leakage currents 4.1.2 Direct method (Equipment leakage) Measurements shall be performed at mains voltage, and in either position of the mains plug, if applicable, and according to Figure 11, 12. If measurements in different positions of the MAINS PLUG are applicable, the higher value shall be documented. Note 1: If the measuring equipment is supplied by an IT power system, erroneous measured values will result. During the measurement, except for the protective earth conductor in the power supply cord, the equipment shall be isolated from earth. Otherwise the direct method is not applicable. Note 2: An earth potential can be imported, for example, by external data lines. Note 3: When measuring equipment leakage current of Class I ME equipment, test personnel or bystanders can be endangered by an interruption of the protective earth connection. Figure 11 (Equipment leakage, Direct, Class I) Page 12 Figure 12 (Equipment leakage, Direct, Class II) A Practical Guide for Medical Equipment and Electrical System Testing 4. Leakage currents 4.1.3 Differential method (Equipment leakage) Measurements shall be performed at mains voltage, and in either position of the mains plug, if applicable, and according to Figure 13, 14. If measurements in different positions of the mains plug are applicable, the higher value shall be documented. Note: If the measuring equipment is supplied by an IT power system, erroneous measured values will result. When measuring small leakage currents, attention shall be paid to information about limitations from the manufacturer of the measuring equipment. If the value of the differential method exceeds 0,5 mA for Class I ME, either the direct method or the touch current measurement shall be applied (allowable values in Table 3). Figure 13 (Equipment leakage, Differential, Class I) Figure 14 (Equipment leakage, Differential, Class II) Page 13 4. Leakage currents 4.2 Measurement of applied part leakage current Measurement of the applied part leakage current shall be performed on equipment. For TYPE-B applied parts usually no separate measurement is necessary, measurements are encompassed in the equipment leakage measurement. • • • For TYPE-B applied parts usually no separate measurement is necessary, measurementsare encompassed in the equipment leakage measurement. Separate measurements of TYPE-B applied part are necessary only if described by the manufacturer (check accompanying documents). TYPE-F applied part leakage current shall be measured from all patient connections of a single function of the applied part connected together according to Figure 15, 16. Figure 17, 18 or Figure 19, or as described by the manufacturer. Alternatively, for TYPE-CF applied parts measurement can be made from each patient connection in turn. When testing ME Equipment with multiple applied parts, connect them each in turn and comply with the applicable limits in Table 3. Applied parts not part of the measurement shall be floating. Page 14 A Practical Guide for Medical Equipment and Electrical System Testing 4. Leakage currents 4.2.1 Alternative method (Applied part) Measurement in ME equipment having an TYPE-F applied part shall be performed according to Figure 15, 16 for mains operated ME equipment. Figure 15 (Applied part leakage, Alternative, Class I) Figure 16 (Applied part leakage, Alternative, Class II) Page 15 4. Leakage currents 4.2.2 Direct method (Applied part) Measurements shall be performed at mains voltage, in either position of the mains plug, if applicable and according to Figure 17, 18, or according to Figure 19 in ME equipment having an internal electrical power source. Note: If the measuring equipment is supplied by an IT power system, erroneous measured values will result. Figure 17 (Applied part leakage,Direct, Class I) Figure 18 (Applied part leakage, Direct, Class II) Page 16 Figure 19 (Applied part leakage, Direct, Internal power source) A Practical Guide for Medical Equipment and Electrical System Testing 4. Leakage currents 4.3 Measurement of touch leakage current (Alternatively, touch method derived from IEC 60601-1 may be used.) This measurement is only required on accessible conductive parts that are not protectively earthed. Measurements shall be performed at mains voltage, and according to Figure 20, 21. Figure 20 (Equipment touch leakage current, Class I) Figure 21 (Equipment touch leakage current, Class II) Page 17 Sequence of testing Figure 22, contains a recommended sequence for performing the tests described in the standard EN 62353. START Selection of the test Visual INSPECTION PROTECTIVE EARTH RESISTANCE Insulation resistance (not mandatory) Leakage current Functional test Reporting of results Evaluation Check and prepare for normal use Figure 22 (Sequence of testing) Page 18 A Practical Guide for Medical Equipment and Electrical System Testing Sequence for selection of appropriate leakage current Figure 23 contains an example decision chart to assist in determining which test method to apply when measuring leakage currents on non-permanently installed Class I & Class II ME equipment. Close mains part switches EQUIPMENT LEAKAGE CURRENT No Electronic switched mains? Yes Yes No Class I? Yes Protective earth resistance complies? Repair No EQUIPMENT LEAKAGE CURRENT - differential method (Figure 13, 14) APPLIED PART LEAKAGE CURRENT No F-Type APPLIED PARTS? Active circuitry? Perform applicable tests Value exceeds Yes 1 mA? No Yes Measure each applied part in turn with other applied parts left floating Yes Pass? Equipment isolated from earth? EQUIPMENT LEAKAGE CURRENT - direct method (Figure 11, 12) or - differential method (Figure 13, 14) No Yes Insulation resistance measurement specified? Yes LEAKAGE CURRENT according IEC 60601-1 Measurement of leakage current EQUIPMENT LEAKAGE CURRENT alternative method (Figure 9, 10) Repair No No POLYPHASE EQUIPMENT LEAKAGE current value exceeds the limits of Table 3? No No Close mains part switches Yes Switch on equipment Yes APPLIED PART LEAKAGE CURRENT - direct method (Figure 17, 18) or Equipment with AN INTERNAL ELECTRICAL POWER SOURCE (Figure 19) APPLIED PART LEAKAGE CURRENT - alternative method (Figure 16, 17) DOCUMENTATION Figure 23 (Sequence for selection of appropriate leakage current) Page 19 AUTO SEQUENCE® Automatized test procedures or shorter AUTO SEQUENCE®s are one of Metrel’s most recognized innovative feature for many years. MI 3360 M OmegaPAT XA with colour touch screen in combination with Metrel Electrical Safety Manager Software, shorter called MESM has placed this feature on a completely new level. Figure 24 (Metrel Electrical Safety Manager - Auto Sequence editor) Page 20 A Practical Guide for Medical Equipment and Electrical System Testing AUTO SEQUENCE® The MI 3360 OmegaPAT XA enables the user to select Metrel’s predefined AUTO SEQUENCE®s, developed for medical applications, in accordance with IEC/EN 62353. In addition to these predefined sequences the users can create their own custom sequences, using our MESM AUTO SEQUENCE® editor. This tool enables the creation of sequences including comments, wire diagrams, pictures and custom visual or functional inspections. In addition to this feature, there are no limitations about the design of the sequence flow, quantity of the used steps for specific test or quantity of the comments or pictures used. Figure 25 (List of sequences by cryteria) Figure 26 (Connection diagrams) Page 21 AUTO SEQUENCE® For a skilled user such custom-made AUTO SEQUENCE®s can reduce time for testing, and on the other hand for the unskilled user can make testing easier by checking comments connection diagrams and flow of the test sequence. Figure 27 (Basic Auto Sequences) Figure 28 (Alternative Auto Sequences) Figure 29 (List of applicable tests) Figure 30 (Selection of multiple points) Page 22 A Practical Guide for Medical Equipment and Electrical System Testing Professional reporting Measurements are given in appropriate measuring reports / records with a tabular representation of results as may be seen in the example of sample measurements down below. Figure 31 (Detailed test information) Figure 32 (Complete test results) Page 23 METREL d.d. Measuring and Regulation Equipment Manufacturer Ljubljanska 77, SI-1354 Horjul, Slovenia T +386 (0)1 75 58 200, F +386 (0)1 75 49 226 metrel@metrel.si, www.metrel.si Photographs in this catalogue may slightly differ from the instruments at the time of delivery. Subject to technical change without notice. A Practical Guide for Medical Equipment and Electrical System Testing _Ang_2021
0
You can add this document to your study collection(s)
Sign in Available only to authorized usersYou can add this document to your saved list
Sign in Available only to authorized users(For complaints, use another form )