BENG 360 HW1 (30 pts)
Due Tuesday, September 9th by 11:59 PM
Instructions: Please submit your homework assignment through Canvas as a PDF document. Please name
the file for your exam using the following convention (applies to all homework from now on):
<Lastname>_HW#_<date>.pdf. For example, my submission for HW#1 would be called
Lemonnier_HW1_09092025.pdf. Thanks!
1. (8 pts) Reflection and Transmission
Consider an ultrasound pulse passing through a 3 mm skin layer followed by a 3 cm fat layer. Assume
skin has a density of 1200 kg/m3 and speed of sound of 1720 m/s and fat has a density of 900 kg/m3 and
a speed of sound of 1440 m/s:
a. What is the acoustic impedance of skin and fat (be careful about units)?
b. What is the intensity (energy) reflection coefficient at the skin-fat interface?
c. What is the transmission coefficient at the skin-fat interface?
d. If the incident ultrasound intensity on the skin/fat interface is 100 mW/cm2, what is the transmitted
intensity of ultrasound after it passes through the skin and enters fat?
2. (2 pts)
a. What is the difference between a longitudinal and transverse wave? Are ultrasound waves in the
human body longitudinal or transverse?
b. What is speckle and what does it represent?
3. (20 points) Assume that you have a 16-channel ultrasound system with a linear array transducer (this
means that 16 transducer elements are used at a time for beamforming), imaging a soft tissue medium.
Assume that the spacing between the centers of the elements is 300 microns. Calculate the time delays
for each of the 16 elements for focusing at a point 10 cm from the transducer face. Perform the
calculations in MATLAB and plot the delays vs. element numbers. What happens if you increase (12
cm) or decrease (8 cm) the focusing depth? Assuming that the system has a digital beamformer, what
is the minimum sampling frequency needed in the analog-to-digital converter in the receive path (10cm
focus)?