Toronto Metropolitan University - CPCS 130 Magnetic Fields Introduction In this experiment, we study magnetic fields generated by moving electric charges - commonly referred to as electric current. Electric current is commonly ‘shaped’ into a particular path, or direction, by using conductive materials such as metal. The configuration of these paths dictate the resulting magnetic field generated by the electric current. Magnetic fields created by electric current can be calculated by the Biot-Savart Law. ⃗ = dB ⃗ × r̂) µ0 I(dL 4π r2 (1) ⃗ at a distance The equation states that an infinitesimal (very very small) magnetic field dB, ⃗ r away from the conductor, is generated by an infinitesimal section of the conductor, dL, ∗ carrying electric current, I. The constant µ0 is the vacuum permeability . By integrating ⃗ an equation for the magnetic field is determined. dB, Magnetic Field near a Long, Straight Conductor Consider a long, straight (infinite) conductor with electric current, I. By integrating along the length of the conductor, we discover that the magnetic field at a distance r away from the conductor is: ⃗ wire (I, r) = µ0 I 1 θ̂ B 2π r (2) Figure 1: Magnetic field (arrows) near a long, straight conductor with current flowing out of page ∗ In this lab we use the classical vacuum definition µ0 = 4π × 10−7 H/m Page 1 of 10 Toronto Metropolitan University - CPCS 130 The direction of the magnetic field was determined by the cross product in the Biot-Savart equation. One can intuitively assess the magnetic field direction by applying Right Hand Rule. In this configuration, the direction is θ̂. We also notice that the magnetic field magnitude is less further away from the conductor. Magnetic Field near a Loop of Wire The magnetic field for other configuration, such as a circular loop, can also be determined. Starting from the Biot-Savart equation, and evaluating a similar integral, the magnetic field for a loop of conductive wire with radius R along the central (perpendicular) axis, z, and electric current I is: 2 ⃗ loop (I, z) = µ0 I p R ẑ B 2 (z 2 + R2 )3 (3) Applying Right Hand Rule, we determine that the magnetic field points in the ẑ direction. R z I Figure 2: Cylindrical coordinate system for a single loop of wire If we observe Eqn. 3, one method of increasing the magnitude of the magnetic field is to simply increase the electric current, I. However, this approach is not necessarily ideal as generating increasingly large electric current comes with many practical difficulties. Instead, by clustering many loops together, one can achieve nearly the same result. The total magnetic field would then be the sum of all the magnetic fields from every individual loop. Assuming these loops are very close together, the difference in position between each other is negligible thus leading to the following result: Page 2 of 10 Toronto Metropolitan University - CPCS 130 ⃗ coil (I, z, N ) = N B ⃗ loop (I, z) B (4) Pre-Lab Questions Submit your answers to the pre-lab questions on D2L prior to the beginning of your lab session. Your lab teaching assistant may review these questions with you during your lab session. Note: Pre-lab questions are to be submitted individually. ⃗ coil as a function of electric 1.) Write the expression for the magnetic field of a coil B current I at the centre, on the same plane as the coil (z = 0). Next, calculate the slope (including units) of the function for a coil N = 100 turns, and radius R = 0.15 m. 2.) If the same coil (N = 100, R = 0.15 m) is energized with I = 1 A, sketch the the magnetic field strength as a function of position along the central axis, z, from z[m] = −0.4m to 0.4m. ·10−4 5 B(z) [T] 4.5 4 z[m] 3.5 -0.40 -0.30 -0.20 -0.10 -0.05 0.00 0.05 0.10 0.20 0.30 0.40 3 2.5 2 1.5 1 B(z)[T] ∗10−4 0.5 0.40 0.30 0.20 0.10 −0.10 −0.20 −0.30 −0.40 z [m] Page 3 of 10 Toronto Metropolitan University - CPCS 130 Apparatus Measuring magnetic fields in this lab are achieved by using a Hall-effect transducer. The sensor measures only the component of the magnetic field that is perpendicular to the end of the sensor. A positive value indicates that the sensor is pointing to magnetic south. Electric currents above 100 mA are dangerous to humans. Care must be taken when connecting or disconnecting cables to the power supply. For safety, turn off the power supply when connecting/disconnecting components. The red (+) and black (-) terminals are to be used. Below is a list of all the equipment used in this lab. • Power supply • Vernier LabPro + Logger Pro software • Retort stand + ruler + holder • Vernier magnetic field sensor • 2 × Magnetic field coil [200 turns, 10.5 cm radius] + base • Clamps • Electric cables • Elastic Bands Part I - Magnetic Field at the Centre of a Single Coil Procedure I 1.) Connect the Magnetic Field Sensor to CH-1 of the LabPro computer interface. 2.) Open Logger Pro and check if your LabPro is properly connected, an icon should appear in the top left of the screen if it is. 3.) Click Experiment → Zero to calibrate the field sensor. 4.) With the power supply off, connect a single coil using the white plugs to the power supply. 5.) Using Right Hand Rule, determine the direction of the magnetic field generated by the coil. Hint: Observe the wiring diagram near the plugs of the coil. 6.) Ensure that the sensor is set to the 6.4mT range via the toggle switch on the body of the probe. When changing ranges, LoggerPro will prompt an indication that the sensor settings have changed; Click Use Sensor Settings to continue. 7.) To the best of your ability, position the probe (which should be attached to the end of the meter stick) so it is perpendicular to, and along the central axis of the coil. Page 4 of 10 Toronto Metropolitan University - CPCS 130 8.) Position the probe so that is in the same plane as the coil. The probe will stay in this position for this part of the lab. 9.) With the power supply Off, remove the effect of any local magnetic sources that may contribute to the measurement by zeroing the sensor. This is done by clicking the ∅ button on the LoggerPro interface. 10.) Turn on the power supply and set the electric current to 0.4A. Note that prolonged energization can and will affect the electric current value due to self-heating of the wires. To avoid this, do not leave the system energized (power supply on) for longer than necessary. 11.) Take a measurement by clicking the ▶ button on the LoggerPro interface. Data will collect over 10 seconds. 12.) In the LoggerPro interface, the top graph displays the magnetic field vs. time. Select an adequate region on the graph that best represents the measurement. If the whole measurement is adequate, you can skip highlighting a region and use the full measured data set. 13.) With the top graph selected, select Analyze → Statistics to obtain a time averaged magnetic field and corresponding standard deviation of the selected (or full) region. 14.) Record the magnetic field results, as well as the electrical current (and associated uncertainties) in the excel sheet provided on D2L. 15.) Assign an uncertainty to your magnetic field value based on the fluctuations observed over the span that data was collected. Based on the stability of the measurement, justify whether this time average collection is needed or if the live readout in the bottom left of LoggerPro is adequate. • If you choose to use the live readout you will still need to include an uncertainty value on your measurements; be sure to justify the magnitude of your uncertainty. • If you believe a time averaged measurement is needed you should still reduce your collection time (as you are under a two hour time constraint). Reduce the collection time 3s, Experiment → Data Collection → Duration = 3s. 16.) Measure the magnetic field every 0.2 A up to a maximum of 2 A. Record the results and electric current, I, each time. 17.) Determine the relationship between the magnetic field of a single coil, Bcoil , and electric current, I by plotting your results and applying a linear fit. Page 5 of 10 Toronto Metropolitan University - CPCS 130 Analysis I 1.) Compare the relationship between I and BCoil with the expected value. 2.) Check your measurement accuracy by comparing your result to the permeability of vacuum and calculating the percent error. 3.) Comment on the precision of your measurement, whether or not the result is within an acceptable range (ie within the uncertainty) and discuss possible sources of error. 4.) What would you expect to happen if you performed the same experiment slightly out of the plane of the coil? Page 6 of 10 Toronto Metropolitan University - CPCS 130 Part II - Magnetic Field along the Central Axis of a Single Coil Procedure II 1.) With the power supply Off, zero the magnetic field sensor while it is still at the centre of the coil. 2.) With a single coil still connected, set the power supply so that the current is 2 A when it is on. 3.) With the power supply on, move the probe and ruler (as a single entity) away from the coil until it reaches approximately 20% of the maximum magnetic field strength. Aside: Where would you expect the maximum magnetic strength value to be? 4.) In Excel, switch to the second sheet (Bz vs. z). 5.) Starting from the position determined above, take and record measurements of the magnetic field strength and position along the central axis in increments of 2 cm until you reach approximately the same magnetic field strength on the opposite side of the coil. Remember, in general, the more data points obtained, the greater the fit will likely be when fitting the data. 6.) You should record an uncertainty value for the magnetic field sensor’s position. 7.) Unlike in Part I, we are unable to use a simple linear fit due to the complexity of the equation. Instead, we create a fit by creating a set of data from the theoretical equation. Knowing that your data should follow Eqn.[3] try fitting your data to: ⃗ coil (I, z) = A B B2 ẑ ((z + C)2 + B)2 )3/2 (5) where A, B and C are fitting parameters (free for you to adjust). Analysis II 1.) Comment on your fitting coefficients and compare them to their corresponding expected values (Based on Eqn.[3]). Calculate a percent error for these coefficients and discuss sources of error. 2.) Determine the Full Width Half Maximum (FWHM) using the single coil equation and fitting parameters. The FWHM is the measure of how broad (wide) a signal is before it loses half of its intensity. In this case, it’s a measure of the distance spanned (spatially) before the magnetic field magnitude is halved. Page 7 of 10 Toronto Metropolitan University - CPCS 130 Part III - Magnetic Field of a Two Coils Procedure III 1.) With the power supply Off, zero the magnetic field sensor while it is still at the centre of the coil. 2.) Position two coils such that they are within the rectangular outlines on the base. Ensure that the coils are parallel with one another. If the coils are loose from the base, tighten them using the thumb screw underneath. 3.) Connect two coils in series using the white plugs such that the magnetic fields of each coil point in the same direction. Verify that the coils are correctly configured to one another by right hand rule for coils. 4.) Set the power supply to output 1 A of current. 5.) Create a new sheet in your Excel file called Helmholtz Coil. 6.) In a similar fashion to Part II, measure and record the magnetic field across the Helmholtz coil in steps of 2 cm all the way through the two coil system. 7.) Using what you learned, write the equation for the magnetic field of a two coil system with the coils R distance apart. There is a (slightly) elegant way to write this expression. Here are some helpful hints: • Note the quantities that are the same for both coils (N , I, etc) and remember the principle of superposition as it relates to magnetic fields. • Define z = 0 of Btot (I1 , I2 , z) to be in equidistant between the two coils. On the z axis, where are the two coils positioned? • Eqn. 3 assumes that z = 0 when you are in the plane of the coil. • Recall that you can re-parameterize a function by applying a transformation like z → z + z0 where z0 is a constant (or shift). • If you need help or guidance in this process ask your TA. 8.) In a similar manner to Part II attempt to fit your Holmholtz data using the equation you found above and 2-3 fitting coefficients. Page 8 of 10 Toronto Metropolitan University - CPCS 130 Analysis III 1.) Comment on what each fitting coefficient means and compare the relevant ones to the expected values. Calculate the percent error for these coefficients and discuss sources of error. 2.) Calculate the FWHM for the Helmholtz coil and compare it to the FWHM of the single coil in Part II. 3.) Discuss what would happen if the magnetic coils were moved closer together or further apart. 4.) Describe the magnetic field you would observe if the coils had opposite currents (I2 = −I1 ), and specifically address the magnetic field at a point equidistant between the two coils. Last Few Steps 1.) Be sure to record relevant values such as the radius of the loops, number of turns, and distance between the two coils (for Part III) as they will be needed to complete the lab. 2.) Submit .csv (dataset) file to your group submission folder on D2L. 3.) Once this is complete and are certain that the data is saved, restart the computer when all experiments are completed. 4.) Lastly, tidy up your work station and turn off the power supply (after setting values to 0) for your fellow students in other sections. Report Here is a brief guide for writing the report for the lab. Your report should include the following sections: • Introduction – What is the experiment’s objective? • Theory – You may be able to show a derivation of the physics you’re investigating, or you may want to reference a source that provides a description/equation representing the physics you’re investigating. – You may want to provide graphs that illustrate or predict how you expect the system under study to behave. Page 9 of 10 Toronto Metropolitan University - CPCS 130 • Procedure – Explain the systematic steps required to take any measurements. • Results and Calculations – Tabulate your measurements in an organized manner. – Based on your procedure, you should know what your tables – Provide examples of any calculations. • Discussion and Conclusions – Discuss the main observations and outcomes of your experiment. – Summarize any significant conclusions. • References • (Appendices) Page 10 of 10
0
You can add this document to your study collection(s)
Sign in Available only to authorized usersYou can add this document to your saved list
Sign in Available only to authorized users(For complaints, use another form )