LAB WORK REPORT
[Electrical Circuit]
UNIT [1] [AC Signal]
Student Name: Nemat Adil
Mohamed Alamin
NIM: 24524042
Lab work Date:12/3/2025
Group: IP
Laboratory [Electrical Circuit]
Undergraduate Program of Electrical Engineering
Faculty of Industrial Technology
Islamic University of Indonesia
2024
UNIT [1] [AC Signal]
Course Learning Outcomes (CPMK)
Students can generate, observe, and analyze various types of AC signals (sinusoidal, square, pulse,
triangle, sawtooth) using a Function Generator (AFG) and Oscilloscope, as well as accurately measure
signal parameters such as frequency, amplitude, DC offset, and duty cycle.
Objectives of Lab Work
The student can generate AC signals using a Function Generator (AFG) and analyze them.
Theoretical Basis
An AC signal (alternating current), often also referred to as an alternating signal, is a signal whose
value varies between positive and negative values. Unlike a pure DC signal (direct current), which is
independent of time, the value of an AC signal is a function of time (t).
periodic signal
x(t) = x (t + nT), where n = 1, 2, 3, … (Equation 1.1)
Where T is the period of the signal x(t).
The notation x(t) is a general notation, which is conventionally replaced by v(t) for voltage signals and
i(t) for current signals.
Characteristics of AC Signals
A periodic AC (Alternating Current) signal is characterized by the following parameters:
1. Period (T):
The period T is the time taken for one complete cycle of an AC signal. In the SI system, it is
measured in seconds (s).
2.
Frequency (f):
The frequency f is the number of cycles of the AC signal that occurs in one second. In the SI
system, it is measured in hertz (Hz).
3.
Peak Value (Vp or Ip):
The peak value Vp (for voltage) or Ip (for current) is the distance from the zero point of an
AC signal to its maximum value. In the SI system, Vp is measured in volts (V) and Ip in
amperes (A).
4.
Peak-to-Peak Value
The peak-to-peak value Vp-p (for voltage) or Ip-p (for current) is the difference between the
maximum positive and maximum negative values of an AC signal. Just like the peak value, Vp-p
is expressed in volts and Ip-p in amperes in the SI system.
5.
RMS (Root Mean Square) or Effective Value
The RMS/effective value of an AC signal, Vrms (for voltage) or Irms (for current), is the DC
equivalent of the alternating signal. For example, a 10 V DC source can supply 10 W of power to
a load. An AC source with an RMS voltage of 10 V will supply the same 10 W of power. Just like
the peak and peak-to-peak values, Vrms is measured in volts and Irms in amperes in the SI
system.
The RMS value of an AC signal x(t) is calculated using the following formula:
1
𝑇
Xrms = ∫0 𝑥 2 (𝑡)𝑑(𝑡) (Equation 1.2)
𝑇
6.
Phase Angle
If an AC signal is plotted on a Cartesian plane with the x-axis representing the angle, then the
phase angle is the point on the x-axis where the signal begins. The phase angle is usually denoted
by θ (theta) and is expressed in degrees (°) or radians (rad).
Common types of periodic AC signals often encountered in electrical circuits include:
(a) sinusoidal signal,
(b) square signal,
(c) triangular signal,
(d) pulse signal, and
(e) sawtooth signal.
A Function Generator (AFG) is an electronic device used to produce various types of electrical
waveforms over a wide range of frequencies. Common signals generated include sinusoidal, square,
triangle, and sawtooth waveforms. These signals are essential for testing and designing electronic
circuits.
An Oscilloscope is used to observe the shape of electrical signals. It provides a graphical
representation of voltage over time, allowing for accurate measurement of amplitude, frequency,
period, and phase shift
Description of Experimental Steps
In this experiment, various AC waveforms were generated using a function generator and analyzed
using an oscilloscope. The waveform type was first selected on the function generator, starting with a
square wave. The frequency and peak-to-peak voltage were then adjusted to match the values
provided in the observation table.
Next, the output of the function generator was connected to the input of the oscilloscope using a
probe, following the standard configuration. Once the signal was displayed on the oscilloscope, its
peak-to-peak voltage and period were carefully measured.
A single cycle of the waveform was drawn, and the corresponding time/div and volt/div values were
recorded on the observation sheet. This process was repeated for different waveform settings,
following the experimental requirements.
Practical Results and Analysis
Measurement of Frequency and Amplitude
No 1
1
1
𝑓
40
T= =
= 25 ms
No 2
1
1
𝑓
500
T= =
= 2 ms
No 3
1
1
𝑓
2.5 𝑘
T= =
= 400 us
No 4
1
1
𝑓
100 𝑘
T= =
= 10 us
No 5
1
1
𝑓
400 𝑘
T= =
No Waveform Type
= 2.5 us
Measured Results on
Oscilloscope
AFG Settings
Frequency (Hz)
Vp-p (V)
Period(ms)
Vp-p (V)
1
Square
40
1
24.92
1.52
2
Triangle
500
2
1.924
2.20
3
Sine
2.5 k
1.5
391.6 us
1.6
4
Square
100 k
0.5
9.288 us
0.528
5
Triangle
400 k
1
2.46 us
1.16
The calculated and the measured period (T) are almost the same with a slight difference because the
frequency set on the device is not exactly the same as the required frequency in the worksheet, which
leads to a slight variation.
DC Offset Measurement
AFG Settings
DC Offset Value on
Oscilloscope (V)
No. Wave Type
Frequency (Hz)
Vp-p (V)
DC Offset (V)
1
Square
40
2
0.5
0.5
2
Triangle
500
3
1
1
3
Sine
2.5 k
4
1.5
1.5
4
Square
100 k
5
2
2
5
Triangle
400 k
6
2.5
2.5
Measurement of Duty Ratio (Specific to Square Wave Signal)
𝑫𝒖𝒕𝒚 𝑪𝒚𝒄𝒍𝒆 =
𝑻𝒐𝒏
𝑻𝒐𝒏+𝑻𝒐𝒇𝒇
× 𝟏𝟎𝟎%
NO 1
Duty Cycle = 10.04%
𝑫𝒖𝒕𝒚 𝑪𝒚𝒄𝒍𝒆 =
𝑻𝒐𝒏
𝑻𝒐𝒏+𝑻𝒐𝒇𝒇
× 𝟏𝟎𝟎%
NO 2
Duty Cycle = 24.508%
𝑫𝒖𝒕𝒚 𝑪𝒚𝒄𝒍𝒆 =
𝑻𝒐𝒏
𝑻𝒐𝒏+𝑻𝒐𝒇𝒇
NO 3
Duty Cycle = 40.60%
× 𝟏𝟎𝟎%
𝑫𝒖𝒕𝒚 𝑪𝒚𝒄𝒍𝒆 =
𝑻𝒐𝒏
𝑻𝒐𝒏+𝑻𝒐𝒇𝒇
× 𝟏𝟎𝟎%
NO 4
Duty Cycle = 55.71%
𝑫𝒖𝒕𝒚 𝑪𝒚𝒄𝒍𝒆 =
𝑻𝒐𝒏
𝑻𝒐𝒏+𝑻𝒐𝒇𝒇
× 𝟏𝟎𝟎%
No 5
Duty Cycle = 80.38%
No.
AFG Settings
Measurement Results on the Oscilloscope
Frequency (Hz) Duty Ratio (%)
Ton (ms)
Toff (ms)
Duty Ratio (%)
1
40
10%
2.479
22.20
10.05%
2
500
25%
477.9 us
1.472
24.51%
3
2.5 k
40%
157.5 us
230.4 us
40.88%
4
100 k
55%
5.582 us
4.437 us
55.71%
5
400 k
80%
2.011 us
490.6 ns
80.22%
It was observed that the calculated and measured duty cycles were equal, indicating accurate signal
generation and measurement.
Conclusion
The experiment successfully demonstrated the generation and measurement of various AC
waveforms using a function generator and an oscilloscope. The measured frequency, amplitude, DC
offset, and duty cycle values closely matched the calculated values, confirming the accuracy of the
equipment and the effectiveness of the experimental procedures.
References
[1] G. Rizzoni. Fundamentals of Electrical Engineering. New York, NY: McGraw-Hill, 2009.
[2] GW Intec. Synthesized Function Generator SFG-2100/SFG-2000 Series User Manual.
Taipei, Taiwan: Good Will Instrument, Co., Ltd.
[3] GW Instek. Function Generator GFG-8215A/8216A/8217A/8219A Series Instruction
Manual. Taipei, Taiwan: Good Will Instrument, Co., Ltd