MER 331L
Yifei Guan
Lab 1
1- Intro
2- Writing
3- Uncertainty Review
4- Power from a Model Wind Turbine
Instructor and Course Expectations
• I hold you to a high standard
•
•
•
•
•
Late = 0
Does not follow instructions = 0
Know the deadlines, put them in your calendar
Read instructions
Accuracy is important
• You must start working on analysis and writing as soon as your data is collected
• The analysis is involved and will require visits to office hours to get questions answered
• First drafts are not graded generously
• It is expected that you apply what you’ve learned in MER 262
• Technical writing, figure/table quality, etc.
• If you have questions, visit office hours and ask
• Take feedback seriously and don’t repeat mistakes
• Go through multiple drafts
How well you communicate is important
• Successful engineers spent 25% of work week writing
• Richard M. Davis, Technical Writing: Its Importance in the Engineering
Profession and Its Place in the Engineering Curriculum, AFIT TR 75-5 (WrightPatterson AFB, Ohio: Wright-Patterson Air Force Base, 1975).
• Professional engineers found writing their most useful subject in
college
• Dean John G. Bollinger, “Alumni Survey Results,” Perspective (Madison: College
of Engin. U. of Wisconsin, Summer 1994), p. 2.
• Recruiters claim that engineers need more work on their writing
• Virginia Tech, College of Engineering, “Summary Report of Employer Focus
Group” (October 2000).
• Communication is a strength for Union
• Alumni report it among the most useful skills learned at Union
Things to Consider
• What is being written
• Research article, proposal, poster, letter to a friend, email to prof., ……
• Audience
• Technical vs. non-technical
• Level of knowledge
• What to include
• Grammar, punctuation, spelling, and format
• Important because it affects clarity and your confidence in the writer
Uncertainty Analysis: Lingo
Error - difference between true value and
measured value.
Note: “Error” is not a “mistake”
Since the true value typically can’t be known
(we only know the measured value) we cannot
exactly calculate the error
Uncertainty Analysis: Lingo (Cont.)
The term uncertainty is used to refer to “a
possible value that an error may have”
The uncertainty of a measurement is a value
that we calculate which we are fairly confident
will be just large enough to contain the largest
errors which are likely to occur
Error Types
Two general categories of error:
Fixed error (Bias) – The same repeatable error will happen for every
measurement made. (e.g. you are weighing something with a scale that is
“off” by 10%)
- Bias errors shift the mean of the data away from the true value
- This kind of error can be removed by calibration
- If you keep careful records error removal can even be done retroactively!
(so keep careful records!)
Random error – These are errors that can’t be removed by calibration.
-These errors impact the standard deviation of our data
-We must quantify them by uncertainty analysis
How to Calculate the Uncertainty?
Consider a function R = f(X1, X2, X3, …, XN)
The uncertainty in R due to the uncertainty in X1, X2, X3, …, XN is:
1/ 2
N R
R
X i
i 1 X i
δR is the uncertainty in R
2
𝜕𝑅
is the partial derivative of R w.r.t. Xi (also know as the sensitivity
𝜕𝑋𝑖
coefficient)
δXi is the uncertainty in Xi
How to Calculate the Uncertainty in Xi (δXi)?
1- Use ± ½ smallest scale division as an estimate
How to Calculate the Uncertainty in Xi (δXi)?
2- Statistically (when you have multiple trials y1, y2, y3,…,yn)
• Average
𝑦=
𝑛
𝑗=1 𝑦𝑖
𝑛
• Standard Deviation
𝜎 =
• Standard Error
𝑛
2
𝑗=1(𝑦𝑖 − 𝑦)
𝑛−1
𝜎
𝑆𝐸 =
𝑛
How to Calculate the Uncertainty in Xi (δXi)?
2- Statistically (when you have multiple trials y1, y2, y3,…,yn)
• Average: use as the best estimate of the true value of the
measured quantity.
• Standard Deviation: use as an indicator of the spread of the trials
within your experiment (± 2σ for the 95% confidence interval).
• Standard Error: use as the estimate of the uncertainty in the
calculated average (± 2SE for the 95% confidence interval).
Simple Example
An engineer is tasked with estimating the volume of a
cube. To keep things interesting, he/she measures the
length of each side with a different ruler. He/she obtains
the following measurements: 10 ± 0.5 cm, 10 ± 0.1 cm,
and 10 ± 0.2 cm. What is the percent uncertainty in
his/her volume estimate?
Experiment: Overview
• Determine power from a model wind turbine as a function of
velocity
• ~12 cm diameter wind turbine models with 2 – 6 blades
• Turbines are connected to DC motors run as generators
• Generators are loaded with a 39 Ohm resistance
• Voltage is measured across the resistance
• Power is determined as P = V2/R
Experiment: Instrumentation
• Wind Tunnel
• Suction wind tunnel, 12’’ x 12’’ cross section, frequency-controlled fan
• DAQ
• Tachometer
• Strobe
• Hotwire Anemometer
Experiment: Details
• Choose a wind turbine model
• Measure model diameter
• Measure velocity using hotwire for frequencies 9 – 21 Hz in
increments of 2 Hz
• Measure voltage for each frequency using DAQ
• 100 readings collected at 5 readings per second
• Measure RPM for each frequency using tachometer
• Use strobe to verify tachometer reading
• Make sure to record values needed for calculations and uncertainty
Experiment: analysis and writeup
• Analyze power and tip speed ratio as a function of
velocity for
• Your wind turbine model
• Another model chosen from a different group
• Include a complete uncertainty analysis
• Uncertainty in tachometer readings: ±3%
• Uncertainty in velocity: ±4%
• Uncertainty in R: ± 1 Ohms
• Use error bars on figures to indicate uncertainty
Experiment: Write-up
• As a group, you will write a full lab report to
communicate the results of this experiment.
• Due at 5:30 pm Friday 09/12/2025
• Revision is due at 5:30 pm Friday 09/19/2025.