Chemistry 51 Laboratory Manual Mt. San Antonio College Chemistry Department 2023 - 2024 Student _____________________________ Professor ____________________________ Locker number: _______ Combination: ___ - ___ - ___ TABLE OF CONTENTS PREFACE GENERAL INFORMATION 1 INFORMATION Safety ……………………………………………………………………………………………. 3 Equipment ……………………………………………………………………………………….. 9 EXPERIMENTS Using Common Laboratory Equipment 13 Data Analysis and Lab Report Preparation Using Excel and Word for Using Common Lab Equipment Experiment 25 Data Analysis and Lab Report Preparation Using Excel and Word 37 Kinetics of the Acetone Triiodide Reaction by the Initial Rates Method …………………………. 49 Kinetics Activity: Integrated Rates Method …………………………………………………….. 61 Equilibrium of a Complex Metal Ion …………………………………………………………….. 73 pH and Hydrolysis of Salt Solutions ……………………………………………………………... 91 Preparation and Properties of Buffers ……………………………………………………………. 101 Titration ………………………………………………………………………………………….. 111 Oxidation-Reduction Reactions ………………………………………………………………….. 127 Electrochemistry and Cell Potentials …………………………………………………………….. 147 Bonding, Structure, and Properties of Organic Compounds …………………………………….. 157 PREFACE The laboratory component of a chemistry course is an important and integral part of the learning experience for all chemistry students. The laboratory provides the students with a hands-on experience in learning chemistry skills and techniques while conducting experiments. The laboratory has its own unique measurable objectives that are introduced, practiced, and assessed through a variety of learning experiences, including inquiry-based and/or open-ended learning. The laboratory manual has been specifically designed with the following objectives: • To complement and reinforce concepts learned in lecture • To conduct experiments using “green” chemical principles—less hazardous or toxic materials, smaller sample sizes, reduction of waste, etc. • To build student confidence in performing safe and proper laboratory skills and techniques • To encourage a greater appreciation and understanding of the proper use of lab equipment, glassware, and instrumentation • To develop computer skills in data acquisition and analysis • To promote critical thinking in the design, execution, and analysis of laboratory experiments • To introduce the organizational use of the laboratory notebook in preparation for technical writing in lab reports • To provide a lab manual at the lowest possible cost to students The objective of the laboratory component of the course is for the chemistry student to gain the necessary skills and confidence to work safely, efficiently, and independently in any future chemistry laboratory. Chemistry 51 2023-2024 Page 1 Chemistry 51 2023-2024 Page 2 SAFETY The chemistry laboratory is potentially a hazardous place and in order to have a safe chemistry laboratory experience for everyone, students must know and adhere to the following guidelines. Before coming to lab • Students should be thoroughly familiar with the experiment being performed by reading the entire procedure ahead of time. Be familiar with the hazards posed by chemicals, apparatus, and procedures. Know how to protect yourself and others. • Students should come to the lab properly attired. This means wearing closed-toe shoes that cover the entire foot, tying long hair back, and removing dangling jewelry. Avoid loose fitting clothing, bulky sweaters, synthetic fabrics (due to flammability concerns), and clothing that expose bare skin such as mid-drifts, short skirts or short shorts. • Students should know the location of safety items such as the safety shower, eye wash stations, first aid kit, fire extinguishers, material data safety sheet (MSDS), chemical-spill kits, and exits. In addition, students should know proper procedures for using the safety shower and eye wash station, and know what to do in case of an accident. Working in the lab • Chemical splash goggles, that provide a complete, snug seal around the eyes, MUST be worn in the laboratory area at all times. Safety glasses or spectacles do not provide adequate protection from chemical splashes and cannot substitute for safety goggles. • Eating, drinking, chewing gum or tobacco, smoking, or applying cosmetics is not allowed in the lab areas. Avoid skin contact with chemicals. While in lab, avoid touching your face (eyes, mouth and nose). At no time should students taste chemicals and, absolutely no pipetting by mouth. Remember to wash your hands frequently throughout the lab, and especially when you leave the lab. • Never perform unauthorized experiments or make changes to the quantities or types of chemicals used in the experiment. Any alteration must have prior professor approval. Remember, never leave your work unattended and never work alone in the laboratory. • Avoid trip hazards. That means keeping your book bags, sweaters or other personal items off the floor and out of the walkways and storing them in the cubbies where provided. Make sure that locker drawers are kept closed when not in use. • When conducting laboratory activities, be sure to carefully read labels on all reagent bottles, notify your professor of all accidents no matter how small, and report and cleanup all chemical spills. Do not pour excess chemicals back into the reagent bottles. Never remove chemicals from the laboratory without proper authorization. • When moving about in the laboratory, walk slowly and anticipate other students backing up or changing directions suddenly. If you stumble or fall while carrying glassware or chemicals, try to project the items away from you and others. Chemistry 51 2023-2024 Page 3 SAFETY • Good housekeeping is part of safety and good laboratory practices. This includes keeping your immediate area clean and clutter free, avoiding drips, drizzles and spills when transferring liquid chemicals, and maintaining a professional attitude. Keep chemicals and glassware away from the edges of the lab bench. Dispose of chemical wastes, broken glass, and paper towels in appropriate containers. • Take extra precaution when using glassware and heat. Be sure that the glassware used is free from cracks and other defects. When heating test tubes, be careful not to point the test tube at yourself or another student. Protect your hands with paper towels and use lubrication when inserting thermometers and tubing into stoppers. • Chemicals that give off toxic, flammable, or offensive vapors should be used in the fume hood. Keep your head out of the hood and be sure that the window sash is pulled down as far as possible during use. The sash should be completely pulled down when not in use. Waste disposal • Solid and chemical wastes should be disposed of in the labeled chemical waste container found in the fume hood. They should never go down the drain, unless specifically instructed to do so. • Used paper towels, used matches (be sure to wet them first), etc should be disposed of in the regular trashcan. • Broken glassware should be placed in the specially marked broken glassware containers. They should never be put into the regular trashcan. In case of accidents • Inform your professor of any accidents, no matter how small. Seek immediate medical attention following the accident as instructed. Chemical spills/splashes: o For small liquid spills on the skin, wash the affected area immediately with flowing water for 15 minutes o For spills covering a large part of the body, immediately get underneath the chemical safety shower. Remove any contaminated clothing while under the shower and deluge the affected body area with water for at least 15 minutes. o For chemical splashes in the face while wearing goggles, immediately go to the eye wash station and flush the area with water for 15 minutes. Do not remove goggles until the chemicals have been washed off. If chemicals got into the eye, pry the eyes open and flush the eyeball with water from the eyewash for at least 15 minutes. Chemistry 51 2023-2024 Page 4 SAFETY Spill Clean Up: o For solid spills, use a dustpan and broom to sweep up the chemicals and dispose of the chemicals in the chemical waste container. Never use your hands to scoop up the chemicals. For spills in the balance, turn off the balance and use the brush to gently sweep the chemicals onto the lab bench first. o For liquid spills on the lab bench or floor, use paper towels or a special absorbent (in the chemical spill kit) to absorb the chemicals, following professor’s directions. For acids and bases, neutralize the spills. If a flammable material is spilled, immediately extinguish all flames and turn off all electrical appliances. Once the area has been properly treated, wash the area with soap and water and wipe dry. Used paper towel or special absorbent must be disposed of in the chemical waste container. https://www.youtube.com/watch?v=Uxa7XLet9oQ https://www.youtube.com/watch?v=wZzDdsdXHrM Fires/burns: o A small fire in a container can be suffocated by placing a watch glass over the mouth of the container. Remove any possible flammable materials away from the area and turn off any electrical appliances and sources of heat. o Be prepared to move away and evacuate the area if the fire is burning over a large area or cannot be smothered quickly. Remember to use stairs and not the elevator. Do not use the fire extinguisher unless you have been specifically trained to do so. o If your clothing catches on fire, stop, drop and roll to smother the flames. The fire can also be put out using the safety shower. Once the fire is put out, wrap the person in a blanket or coat to prevent shock and exposure. Place clean, wet, cold cloths on burned areas. Cuts: o For a small cut, wash the area with soap and water. Apply pressure to stop bleeding if needed and cover the wound with a Band-Aid. o For larger cuts with lots of bleeding, compress the wound with a cloth or pad to control bleeding. Elevate the injury above the heart if possible and wrap the person in a blanket or jacket to prevent shock. Chemistry 51 2023-2024 Page 5 SAFETY Understanding Chemical Labels The chemicals that you will use in this course are labeled according to the Globally Harmonized System (GHS) which is the international standard for chemical labels. The labels use words and pictograms to identify safety issues associated with each chemical. Each chemical label will contain the following information: – – – – Product Identifier (chemical name) Signal Words (“Danger” or “Warning”) Hazard Statements (type and degree of hazard) Precautionary Statements (recommended measures to prevent or minimize adverse effects) – Supplementary Information – Pictograms There are nine different pictograms that represent the various types of hazards that a chemical may pose. The pictograms and their meanings are shown below. Chemistry 51 2023-2024 Page 6 SAFETY The following is an example of a chemical label for 3M HCl. Whenever you use a chemical in the laboratory, you should carefully read the label to make sure that you are using the correct chemical, that you understand the risks associated with using that chemical, and that you know what to do in case of an accident. More detailed information about each chemical is available in the Safety Data Sheet (SDS) for that chemical. SDS’s for all of the chemicals used in the chemistry laboratory are stored in a binder in the prep room. If you would like to view the SDS for any chemical, just ask your instructor. References: Based on the Mt. San Antonio College Chemistry Department Laboratory Safety Rules Adapted from Safety in the Academic Chemistry Laboratories, Volume 1, 7th Edition, a publication of the American Chemical Society and the Joint Board-Council on Chemical Safety. Chemistry 51 2023-2024 Page 7 SAFETY (This page intentionally blank.) Chemistry 51 2023-2024 Page 8 EQUIPMENT 30 mL − − − 20 mL Beaker come in various sizes markings allow measurement of different volumes not very precise 10 mL Erlenmeyer Flask − − come in various sizes not very precise Graduated Cylinder − − come in various sizes calibration markings allow measurement of different volumes medium precision − 0 10 20 Volumetric Pipet − − − come in various sizes single calibration mark allows delivery of only one specified volume very precise 30 40 50 − − − Graduated Pipet come in various sizes calibration markings allow measurement of different volumes very precise − − Funnel − For pouring liquids into flasks − Chemistry 51 2023-2024 Buret come in various sizes calibration markings allow delivery of any desired volume within calibration range very precise Page 9 EQUIPMENT Test Tube Rack − used for holding test tubes Test Tube Brush − Test Tube − used for cleaning test tubes used for holding solutions Crucible Tongs - Test Tube Holder - used for holding a test tube while heating in a Bunsen burner flame Crucible with Lid - used for heating solids to high temperatures - placed on ring stands to support flasks while heating Ceramic Fiber Square - protects lab bench from hot items used for handling hot objects Wire Gauze Wash Bottle - fill with de-ionized water for final rinse of glassware for adding water to flasks Stirring Rod with Rubber Policeman - for stirring solutions for scraping solids Clay Triangle - Sits on a ring clamp for holding crucibles or funnels Chemistry 51 2023-2024 Page 10 EQUIPMENT Medicine Dropper - Filter Paper for dispensing drops of solution - separates solids from liquids Thermometer - measures temperature Rubber Stopper - come in various sizes used to close test tubes and flasks Watch Glass - Vials of Litmus Paper used to cover beakers used to hold/observe solids - come in two colors—red and blue for determining the acidity/basicity of solutions Weigh Boat Spatula - - used to weigh solids used to scoop solids Evaporating Dish - used to evaporate liquids Chemistry 51 2023-2024 Page 11 EQUIPMENT Chemistry 51 2023-2024 Page 12 USING COMMON LABORATORY EQUIPMENT OBJECTIVES: Practice basic laboratory skills involved in making, transferring, and measuring solutions. This activity will utilize the following common laboratory equipment: – Analytical balances – Volumetric flasks – Volumetric pipets – Graduated pipets – Burets – Visible spectrometer INTRODUCTION: Many of the laboratory experiments in Chem 51 involve reactions occurring in solution. For this reason, it is important that students know the proper procedures for accurately and precisely making solutions of given concentration, transferring specific quantities of solution, and measuring a variety of solution properties. In this activity, the student will learn and/or practice important laboratory skills that will be needed for the remaining experiments in this course. In Part 1 of this activity, students will make an aqueous sodium chloride solution, NaCl(aq), of given molarity using an analytical balance and a volumetric flask. Students will then use a graduated pipet to transfer given aliquots of the solution for mass measurements. The data will be analyzed to determine the density of the solution. Students will then use a buret to deliver aliquots of solution for mass measurement. Students will then use the previously determined density and the measured masses to evaluate the accuracy of the buret transfers. In Part 2 of this activity, students will use a colored solution to make a series of dilutions using a volumetric pipet and volumetric flasks. The absorbance of each solution will be measured using a visible spectrometer and plotted to obtain a Beer’s Law constant. Proper procedures for using each of these pieces of equipment can be found in the General Information section of the Chemistry 51 Laboratory Manual. A link to this document is on the Chemistry Department webpage (www.mtsac/chemistry) under “Resources” and then “Lab Manual”. You should read pages 14-23, 25-26, and 28-30 in this document. Videos demonstrating the various laboratory techniques are also linked on the department website under “Resources” and then “Videos”. Watch these videos before attempting the experiment. The software for analyzing the data from Part 2 of the experiment is the Spectrometry app from Pasco Scientific and can be downloaded from Google Play or the Apple App Store. You will need to download this software in order to analyze your data. Chemistry 51 2023-2024 Page 13 USING COMMON LABORATORY EQUIPMENT PRE-LAB QUESTIONS: 1. Define the terms “TC” and “TD” that appear on volumetric glassware. 2. What does “TARE” mean on an analytical balance? 3. Describe the process of “conditioning” a pipet. 4. This 10-mL serological pipet is set to deliver how many mL of solution? (report your answer to the correct place value) 7 8 9 5. To what place value should you record measurements with our 25-mL burets that are marked every 0.1 mL? 6. When dispensing a solution using a buret, the volume of dispensed liquid is equal to a. The liquid level shown on the buret (buret reading) b. 25.00mL minus the liquid level shown on the buret (buret reading) c. The final buret reading minus the initial buret reading d. None of these 7. State Beer’s Law and define its terms. Chemistry 51 2023-2024 Page 14 USING COMMON LABORATORY EQUIPMENT CHEMICALS AND MATERIALS Part 1 NaCl (s) (in bins) Analytical balance (in balance room) Buret stand and buret clamp (in cabinets and drawers under north hood in lab) Part 2 Food coloring solutions (in bins) 10 mL volumetric pipet (in lab drawer) Kimwipes (on bench tops) EQUIPMENT TO BE CHECKED OUT Part 1 100 mL volumetric flask 5 mL serological graduated pipet 50-mL Erlenmeyer flask with stopper Plastic disposable pipet Part 2 100 mL volumetric flask Pasco spectrometer with cuvettes Laptop SAFETY No special precautions needed WASTE DISPOSAL Salt and salt solutions can be poured down the sink drain. Food coloring solutions can be poured down the sink drain. Chemistry 51 2023-2024 Page 15 PROCEDURE: Part 1 Making a Salt Solution and Determining its Density 1. Prepare your laboratory notebook according to your instructor’s directions. 2. Obtain your molarity assignment from your instructor and calculate the mass of NaCl(s) needed to prepare 100 mL of your assigned solution. 3. Check out the equipment for Part 1 from your instructor at the preproom. 4. Use a weigh boat and the “Weighing by Taring” method described on page 19 of the General Information section to measure out the approximate mass of NaCl(s) needed to make your assigned solution. Record the mass including all four decimal places shown on the balance readout. It is NOT important that your measured mass exactly matches your calculated mass, however, it IS important that you accurately record the mass of solid you transfer. 5. Transfer the weighed salt to your 100-mL volumetric flask using a funnel. Use a wash bottle containing DI water to rinse the weigh boat, funnel, and neck of the flask. Add additional DI water with swirling to dissolve the salt, but do not fill to the calibration mark just yet. Once the solid is completely dissolved, continue adding water until the bottom of the meniscus is at the calibration mark. The last few drops of water should be added with a dropper or plastic pipet. Cap the volumetric flask and invert the flask several times while holding the stopper to thoroughly mix the contents. You now have a solution of accurately known molarity. 6. In the following steps, you will use the NaCl(aq) solution that you just prepared. The directions indicate how much solution to use in each step. Do not use more than directed because you only have 100 mL of solution to work with. 7. Pour about 10 mL of your salt solution into a clean, dry test tube to use for conditioning your 5-mL graduated pipet. Use the pipet bulb to load about 2 mL of solution into the pipet. Remove the bulb and tilt and rotate the pipet to rinse the inner walls with solution. Discard the solution to waste. Repeat this process two more times. Chemistry 51 2023-2024 Page 16 8. Make a data table in your notebook (on the right side) to record 4 trials of mass and volume data. Be sure to continue to record your “procedure” on the left side. Trial Volume of aliquot added (mL) Mass of empty Erlenmeyer (g) Total mass of Erlenmeyer and NaCl(aq) (g) 1 2 3 4 9. Weigh your clean, dry 50-mL Erlenmeyer flask with stopper on an analytical balance. The analytical balances are precise to the ten thousandths place. Refill your test tube with fresh NaCl(aq) solution. Use your conditioned graduated pipet to transfer 2.00 mL of solution to your pre-weighed Erlenmeyer flask. Note that the graduated pipet you are using is a “blow out” type of pipet. Follow the appropriate directions from page 17 of the General Information section. The 5-mL graduated pipet volumes should be recorded to the hundredths place. Stopper the Erlenmeyer flask containing the 2.00 mL of solution and re-weigh. (The mass of the solution should be about 2 grams--subtract mass of empty Erlenmeyer from filled Erlenmeyer. If the mass is significantly different from 2 grams, check that you are using the pipet correctly and/or get help from your instructor.) 10. Empty the Erlenmeyer, re-stopper and re-weigh (the mass will likely be slightly higher due to residual solution in the flask, but this is not a problem since we will be subtracting this out anyway). Repeat the process of adding 2.00 mL of solution and weighing 3 more times to give 4 total measurements of mass and volume. You will use this data to make 4 determinations of the density of your solution. 11. In this next part, you will get practice using a buret to deliver volumes of solution. Mount the buret in the buret stand and clamp with a waste beaker below it. Fill the buret with water to check it for leaks. Let some water drain through the tip of the buret until the meniscus is below the 0.00 mL mark and there are no bubbles in the tip. Ask your instructor to check your set up. 12. Record the buret reading to the hundredths place in your notebook. Wait at least 5 minutes and then record the solution level again. If the level hasn’t changed, then your buret is not leaking and you can proceed. If the level has changed, ask your instructor for assistance. 13. Once you have established that your buret is not leaking, drain out the water. 14. Pour about 20 mL of fresh NaCl(aq) salt solution into a clean, dry small beaker to use for conditioning your buret. With the stopcock closed, pour about 5 mL of salt solution into Chemistry 51 2023-2024 Page 17 the buret. Remove the buret from the stand and tilt and rotate the buret to coat the inner walls with solution. Drain this solution through the tip of the buret into a waste beaker. Repeat this process 2 more times. 15. Fill your conditioned buret above the 0.00 mark with fresh salt solution. Drain the solution until the meniscus is below the 0.00 mL mark and make sure that there are no bubbles in the tip. Record the initial buret reading to the hundredths place. 16. Make an appropriate data table in your notebook to collect initial and final buret readings and masses. 17. Use the buret to transfer approximately 2 mL, then 5 mL, then 10 mL of salt solution to the Erlenmeyer flask. Record the initial and final buret readings to the hundredths place each time and record the initial and final mass of the flask to 4 decimal places each time. Part 2 Diluting a Solution and Measuring Absorbance 1. Prepare your notebook for Part 2. 2. Check out the equipment for Part 2 from your instructor at the preproom. 3. Use a clean dry beaker to obtain approximately 100 mL of colored solution from the chemical bin for your bench. Record the appearance and concentration value from the label in your notebook. We will call this “Solution A” 4. Pour out about 10 mL of Solution A into a clean, dry test tube to use for conditioning your 10-mL volumetric pipet. Use the pipet bulb to draw up about 3 mL of solution, remove the bulb, tilt and rotate the pipet to coat the inner walls with the solution, and then discard this solution to waste. Repeat the conditioning step 2 more times. 5. Use your conditioned pipet to transfer 10.00 mL of Solution A to your 100-mL volumetric flask. Add some DI water with swirling until the solution level is near the neck of the flask. Continue adding DI water using a disposable pipet near the end until the bottom of the meniscus is at the calibration mark. Cap the flask and invert several times to completely mix the solution. This will be solution B. Pour all of solution B into a clean, dry, labeled beaker or Erlenmeyer flask and cover with parafilm to prevent evaporation loss. Rinse the 100-mL volumetric flask with DI water for use in preparing the next solution. 6. Prepare Solution C by transferring 20.00 mL (2 aliquots of 10.00 mL each) of Solution A to your 100-mL volumetric flask and filling to the mark with DI water and mixing thoroughly as before. Pour Solution C into a separate clean, dry, labeled beaker and parafilm for later use. Chemistry 51 2023-2024 Page 18 7. Prepare Solution D by transferring 30.00 mL (3 aliquots of 10.00 mL each) of Solution A to your 100-mL volumetric flask and filling to the mark with DI water. Pour Solution D into a separate clean, dry, labeled beaker and parafilm for later use. 8. Prepare Solution E by transferring 40.00 mL (4 aliquots of 10.00 mL each) of Solution A to your 100-mL volumetric flask and filling to the mark with DI water. Pour Solution E into a separate clean, dry, labeled beaker and parafilm for later use. Pasco Spectrometer Instrument Set-Up 1. Place the laptop on one of the metal stands stored under the sink. Turn on the laptop and log in. Connect the USB end of the USB cable provided to a USB port on the laptop (A). Connect the small end of the USB cable into the port on the side of the Pasco Spectrometer (B). A B H E C D Figure 1. Pasco Spectrometer Chemistry 51 2023-2024 Page 19 2. Briefly press and hold the ON/OFF button on the side of the Spectrometer (C) next to the USB port to turn it on. After all three status LEDs (D) blink in sequence, release the ON/OFF button. The USB Status LED will shine green and stay lit. (Note: the Bluetooth Status LED will slowly blink blue. The Battery Status LED may also blink red to show that the battery is charging.) (Conversely, you can pair the device to the laptop using Bluetooth without the USB cable.) 3. Open the Spectrometry application on the laptop. (If the icon is not on the task bar, use the Window’s search feature to locate the application. Note that this application is available for download for free from the Pasco Scientific website https://www.pasco.com for home use.) 4. The following screen (Figure 2) should appear on the laptop. Click on the Windows “square” at the top right of the screen to “maximize” the window. Make sure you are clicked on the ABSORBANCE/TRANSMITTANCE tab rather than Fluorescence. To toggle between the filled rainbow background and blank screen, click on the SHOW COLOR SPECTRUM icon (m) at the bottom of the screen. MAXIMIZE a b h i c j e d k l f g m Figure 2. Pasco Spectrometer Software Application Analyze Solution Screen and Icon Labels Chemistry 51 2023-2024 Page 20 5. Click on the ANALYZE SOLUTION (b) from the menu at the top of the screen. 6. The Spectrometer next needs to be calibrated. The first calibration is a “dark” calibration. Cover the sample well with your finger to block ambient light from entering the detector. Then select CALIBRATE DARK (i) from the menu at the bottom of the screen. A check mark will appear when the calibration is complete. 7. Fill the reference cuvette about 3/4ths full with deionized water to use for the reference calibration. Handle the cuvette on the ribbed sides and wipe the smooth sides with a KimWipe. Insert the cuvette into the sample holder on the Spectrometer with the clear sides facing the white light source icon (E) on the Spectrometer (see Figure 1). Select CALIBRATE REFERENCE (j) from the menu at the bottom of the screen. A check mark will appear when the calibration is complete. Remove the reference cuvette and set aside. Measuring the Absorbance of Solutions A-E 8. In this experiment, we will be measuring the absorbance of the colored solution at a specific wavelength. We first want to take an absorbance spectrum of the solution to determine the best wavelength to use. Condition and then fill the sample cuvette about 3/4ths full with Solution A. Select the RECORD circle (h) at the bottom left of the screen to start analyzing the solution. (The icon changes to a square while data is being collected.) After a few seconds, select the red STOP RECORDING square to stop data collection. 9. Select SCALE TO FIT (k) to rescale your data. 10. Use ADD COORDINATE (l) to locate a wavelength to analyze on the curve. a) Move the cursor over the small box that appears connected to the text box. A small hand will replace your cursor. Drag the box slowly toward the curve. As you get near the curve, an arrow will appear that indicates a specific wavelength on the curve. Releasing the box will snap the box to the point on the curve the arrow is pointing to. b) Drag the box along the curve to find a desirable wavelength to analyze. This is usually a high point on the curve. (If your curve plateaus near the top of the graph, the absorbance is too large in that area to be used for analysis.) Choose the peak wavelength and then select the blue check mark next to the selected wavelength value to let the instrument know that this is the wavelength to monitor (if the check mark does not appear, try clicking on the text box). Record the chosen wavelength and measured absorbance value in your notebook. Use the camera icon or a screen capture tool to take a picture of you absorbance vs. wavelength plot and save to add to your lab report. Remove the cuvette from the sample holder. 11. Calculate the concentration of dye in each of your prepared solutions B-E using the given concentration of Solution A and the dilution factor used to prepare each diluted solution. Chemistry 51 2023-2024 Page 21 12. In the spectrometer software, select CONCENTRATION from the menu at the top of the screen. A table will appear on the left side of the screen that has columns for concentration and absorbance. In the first concentration cell, enter the value of 0.00 to represent the blank sample, then continue by entering the calculated concentration values of your solutions AE. 13. With Solution A still in the spectrometer, click on the concentration row corresponding to this solution and select RECORD to measure the absorbance. When the absorbance reading stabilizes, select the check mark next to the absorbance to record the value. Record the absorbance value in your notebook. 14. Condition and fill the cuvette with the next solution and place it in the spectrometer. When the absorbance reading stabilizes, select the check mark next to the absorbance to record the value. Record the absorbance value in your notebook. 15. Continue with the remaining solutions. 16. Re-insert the blank cuvette and measure and record a value for this solution as well. 17. Select STOP RECORDING when you are finished. 18. Use SCALE TO FIT to rescale your data. 19. Select SHOW LINEAR FIT to find and display the best fit line and equation. In the line fit text box, a lock icon can be used to set the y-intercept to zero if desired. Ask your professor if you should force a zero intercept on your Beer’s Law plot. Evaluate the linearity of your Beer’s Law plot. Re-make and re-measure any solutions that deviated significantly from the best fit line. When you are satisfied with your plot, record the concentration and absorbance values as well as the best fit equation of the line in your notebook. 20. .Use the camera icon the clipboard using the your report. to take a picture of the Beer’s Law plot. Copy the snapshot to icon. Paste the snapshot into a Word file and save for use in 21. Use EXPERIMENT OPTIONS to save your experiment to your flash drive as a .spfile. Note that these files can only be opened by the Pasco Spectrometry software which is free and downloadable from either Google or Apple app stores. Chemistry 51 2023-2024 Page 22 DATA ANALYSIS: Ask your instructor if you will be following the data analysis steps below or using the accompanying lab report preparation activity to prepare your lab report for this experiment. Part 1 1. Calculate the molarity of your salt solution using your experimental mass of salt (not your calculated value) and 100.00 mL as the total solution volume. 2. Use your mass measurements to calculate the mass of solution transferred using the graduated pipet for each aliquot. 3. Determine the density of your salt solution using your mass and volume results for each of your four trials. Calculate the average density, standard deviation and % standard deviation. 4. Calculate the volume of each aliquot delivered by the buret according to the buret readings: Vsoln = Vf, buret -Vi, buret. 5. Use the density value determined in step 3 and the mass of each aliquot delivered by the buret to calculate the “true value” for the volume of each aliquot delivered by the buret. 6. Calculate the % error in volume for each aliquot delivered by the buret. Part 2 1. Calculate the molarity of each of your colored solutions based on the stock solution concentration and the volumes diluted. 2. Include your absorbance vs. wavelength plot. 3. Include your absorbance vs. concentration plot with linear trendline fit. The slope of your graph is your experimental Beer’s Law constant 4. Calculate the % error in Beer’s Law constant by comparing the slope of your plot with the appropriate “true value” of the Beer’s Law constant for your color dye from the table below. Dye Color Beer’s Law Constant for ο¬max red 2.6 x104 M-1 green 4.3 x104 M-1 blue 1.2 x105 M-1 Chemistry 51 2023-2024 Page 23 POST-LAB QUESTIONS: 1. Discuss the precision of your density determinations using the graduated pipet. Use the following guided questions to help you formulate your response. a. To what place value did you report your density values? b. What was the range of your calculated density values? c. Did your range of values match the expected precision you reported? If not, what experimental issues do you think contributed to the lack of precision of your results? d. Which experimental procedure—measurement of mass or volume—was less precise? e. How could you improve the precision of this experiment? 2. Discuss the accuracy of your buret volumes. Use the following guided questions to help you formulate your response. a. Assuming that you can accurately read a buret to within 0.05 mL, what is the maximum expected % error for dispensing 2mL? 5mL? 10 mL? b. How did your experimental % errors for the buret volumes compare to the values calculated in 2a? c. What changes could you make to the experiment to improve the accuracy of the delivered volumes? 3. Discuss the precision and accuracy of your Beer’s Law plot. Use the following guided questions to help you formulate your response. a. How close are your data points to the best fit line? What is the average % difference between the measured absorbance and the best-fit absorbance for a given data point? b. The expected precision of the volumetric glassware used in Part 2 is about 0.2%. Do your results agree to this level of precision/accuracy? What do you think are the largest contributors to errors in this part of the experiment? REFERENCES: Written by Janet Truttmann, Fall 2021, revised 6/2022 Chemistry 51 2023-2024 Page 24 DATA ANALYSIS AND LAB REPORT PREPARATION USING EXCEL AND WORD FOR USING COMMON LABORATORY EQUIPMENT LAB OBJECTIVE(S): • • • • • • • Practice spreadsheet data entry and display formatting with Excel Use formulas in Excel for repetitive calculations Plot scatter graphs from spreadsheet data in Excel Analyze graphical data Transfer Excel tables and graphs to a Word document for lab reports Enter formulas in Word using subscripts and/or superscripts and the equation editor Complete your lab report for the “Using Common Laboratory Equipment” lab experiment INTRODUCTION: An important component of scientific work is the analysis and reporting of experimental results. In this activity you will review and build on the computing skills you learned in Chem 50. You will use the Excel spreadsheet program to make data and results tables, enter formulas for calculating experimental results from data, and create and analyze charts. You will transfer your Excel tables and charts to a Word document as you would for a lab report. Finally, you will use the equation editor feature of Word to type chemical equations and mathematical formulas/expressions. It is expected that students are able to perform the basic Excel functions that were covered in Chem 50. Students should review the Excel tutorial which is contained in the introduction section of the lab manual before attempting this activity if necessary. Please note that different versions of the Excel software have slightly different procedures for some tasks, so use the help feature in Excel to clarify any procedures if necessary. Also, make sure to bring a flash drive to class for saving your work and save early and often. In this activity, you will prepare the data and results sections of your lab report for the “Using Common Laboratory Equipment” experiment according to the guidelines in the handout on lab reports. You should have that handout available to refer to as you complete this activity. PRE-LAB QUESTIONS: Read the following sections in the General Information Section of the Chem 51 Lab Manual before attempting the prelab questions. – “Precision and Accuracy” (pages 37-45) – “Spreadsheet and Graphing with Excel” (pages 46-66) 1. Perform the following calculations using a calculator and report the answers to the appropriate significant figures or place value and show correct units. Indicate whether the Chemistry 51 2023-2024 Page 25 DATA ANALYSIS AND LAB REPORT PREPARATION USING EXCEL AND WORD FOR USING COMMON LABORATORY EQUIPMENT LAB precision of your final answer was based on a “place-value” rule or “# of significant figures rule”. a. 87.1045g + 0.000091g + 39.1g = ? b. (47.68cm x 0.761cm) / (0.36L) = ? c. (60.1m +51.4m) x 13.006m = ? 2. How would a spreadsheet formula be entered that will calculate the following? (Remember that Excel formulas always start with an equal sign and make sure to use correct syntax.) a. the value in cell B5 divided by the value in cell C3? b. the product of the values in cells A2 and C2? c. the sum of values that extend from cell C1 to cell C10 in a spreadsheet? d. the average of all the values in cells from B5 to B9? e. The sample standard deviation of the values in cells C6 to E6? 3. What is a “fixed” cell reference and how do you designate a “fixed” cell reference in Excel? 4. Which of the following icons tells Excel to insert a scatter plot? A) B) C) D) 5. In the Excel tutorial found in the general information section of the lab manual (assigned reading), the finished Calibration Curve for Fe(SCN)2+ Solutions shows a graph of absorbance vs. concentration with a linear trendline fit. A) What was the equation of the line shown on the graph? B) What is the meaning of the R2 value shown under the equation of the line? C) What tool in the Format Trendline menu was used to force a zero y-intercept on the equation of the line? D) What tool in the Format Trendline menu was used to extend the line back to the origin? Chemistry 51 2023-2024 Page 26 DATA ANALYSIS AND LAB REPORT PREPARATION USING EXCEL AND WORD FOR USING COMMON LABORATORY EQUIPMENT LAB CHEMICALS AND MATERIALS student flash drive scientific calculator lab notebook with data from “Using Common Laboratory Equipment” lab completed calculations (handwritten) for “Using Common Laboratory Equipment” handout on Lab Reports EQUIPMENT TO BE CHECKED OUT computer SAFETY none WASTE DISPOSAL none PROCEDURE: Preparing the Data Section of your report using Excel and Word In this section, you will use Excel to create data tables and transfer them into a Word document for your lab report. The data section of your lab report should include both numerical and qualitative data in numbered, titled tables. Numerical values must be shown with units and to the appropriate number of significant figures or to the correct place value. Remember that only data and observations go in this section (no calculated results). Also, you may only include data and observations that are recorded in your notebook. (Falsifying data is considered cheating.) 1. Check out a computer from the professor. Power ON the computer, and launch the Excel and Word software programs. Keep a flash drive handy for file storage. Save the files often during work. 2. In your Word file, type your name and the title of the experiment in the header of the document. Type a section header for the data section of your lab report. Chemistry 51 2023-2024 Page 27 DATA ANALYSIS AND LAB REPORT PREPARATION USING EXCEL AND WORD FOR USING COMMON LABORATORY EQUIPMENT LAB 3. Create a data table in Excel with the following format and enter the relevant data from your “Using Common Laboratory Equipment” experiment. For this activity, put your cells in the indicated rows and columns as these will be specifically referred to in later sections. – Use the “merge cells” feature to merge and center the table title as shown above. – Put borders around the cells. – Set the font to Times New Roman, 12 pt and bold the title. – Use the “increase/decrease decimals” tool or the “format number” tool to force Excel to show the correct significant figures in the data entries. 4. Create an additional data table in Excel for your repeated measurements of 2 mL of your salt solution using the graduated pipet. You can use the “alt enter” feature in Excel to force the units to be on a separate line in the data headers. Enter the relevant data from your lab notebook again making sure to force Excel to show the correct place value on all data entries. Center the contents of each cell both horizontally and vertically using the cell alignment tools Chemistry 51 2023-2024 Page 28 DATA ANALYSIS AND LAB REPORT PREPARATION USING EXCEL AND WORD FOR USING COMMON LABORATORY EQUIPMENT LAB 5. Create the following additional data tables in Excel. 6. Input your data into the above tables in Excel, and then copy and paste the completed tables into your Word document. If you use the “Paste Link” option, your Word table will automatically update if you make changes to the Excel file. 7. Import the absorbance vs. wavelength spectrum of your red dye solution from the Pasco software into your Word document data section. Write a numbered title and caption for your graph that identifies the wavelength chosen for the Beer’s Law analysis. 8. Review your data section for completeness and have your instructor initial your work. Chemistry 51 2023-2024 Page 29 DATA ANALYSIS AND LAB REPORT PREPARATION USING EXCEL AND WORD FOR USING COMMON LABORATORY EQUIPMENT LAB Preparing the Results Section of your report using Excel and Word In this part of the activity, you will use Excel to perform calculations on your experimental data and then transfer the resulting tables and graphs into your Word document. You will also use the Equation Editor in Word to type sample calculations. The Results section will contain numbered equations and sample calculations for each type of calculation, any graphs of calculated results, and numbered and titled tables summarizing your results. 9. Type a new section header in your Word document for your Results section and make subsections for each part of the experiment (Part 1 and Part 2). 10. Use the insert equation editor in Word as necessary to type word descriptions, formulas, and sample calculations for each type of calculation. Example entries for the first type of calculation are shown below. Substitute your own data in the example and then follow the pattern for the remaining calculations as described in the data analysis directions of the lab experiment. Example: Calculating the molarity of the salt solution πππ π πππΆπ moles NaCl = 1 ππππ πππΆπ (58.44 π πππΆπ ) 2.3395 π πππΆπ = (1) 1 ππππ πππΆπ (58.44 π πππΆπ ) Use your own data here = 0.04003 moles NaCl L solution ππΏ π πππ’π‘πππ = = 1 ππΏ (10−3 πΏ π πππ’π‘πππ) 100.00 ππΏ π πππ’π‘πππ (2) 1 ππΏ (10−3 πΏ π πππ’π‘πππ) = 0.10000 L solution MNaCl = = πππππ πππΆπ πΏ π πππ’π‘πππ (3) 0.04003 πππππ πππΆπ 0.10000 πΏ π πππ’π‘πππ = 0.4003 M NaCl Chemistry 51 2023-2024 Page 30 DATA ANALYSIS AND LAB REPORT PREPARATION USING EXCEL AND WORD FOR USING COMMON LABORATORY EQUIPMENT LAB 11. Follow the example above to type equations into your Word document to show how you will calculate the mass of the salt solution aliquots and the density of the NaCl(aq) solution using the mass and volume data from the graduated pipet. Type the formula for each calculation on a numbered line and show one sample calculation for each type with your data for trial 1. 12. Show formulas and sample calculations in your Word document for the statistical analysis of the density determinations following the example shown below. Calculating the Precision of the Density Results average density = ∑(ππππ ππ‘π¦ ππ π π‘πππππ ) π (#) sample calculation with your data ∑(ππ −πΜ )2 standard deviation of density = √ π−1 (#) sample calculation with your data % standard deviation = π π‘ππππππ πππ£πππ‘πππ β 100% ππ£πππππ (#) sample calculation with your data 13. Make an additional table in Excel to perform the necessary calculations using the following headings. 14. Use the formula feature in Excel to populate each cell. For example, in cell H12, type “= C12” to tell Excel that you want the value in cell H12 to equal the value you typed in the data table for the volume of trial 1. In cell I12, type “= E12-D12” to tell Excel that you want cell I12 to calculate the mass of NaCl solution by subtracting the mass of the empty Erlenmeyer Chemistry 51 2023-2024 Page 31 DATA ANALYSIS AND LAB REPORT PREPARATION USING EXCEL AND WORD FOR USING COMMON LABORATORY EQUIPMENT LAB for trial 1 from the mass of the Erlenmeyer and solution. And in cell J12, type “= I12/H12” to tell Excel that you want it to calculate the density of your solution from the mass and volume results for trial 1. To complete the calculations for the remaining trials, copy/paste or drag and drop the formulas for each column. Confirm the results for each by checking with your hand calculator. 15. Make an additional table in Excel to calculate the statistics of your density results from the graduated pipet measurements. In cell M11, type “= average(J12:J15)” In cell M12 type “= stdev.s(J12:J15)” In cell M13 type “=M11/M12” and format the cell for percentages. Copy and paste these tables into the results section of your lab report in Word. 16. Type formulas and sample calculations for the analysis of the buret data into your Word document. • • • • Calculate the volume of each aliquot delivered by the buret using the buret readings (experimental volume). Calculate the mass of each aliquot delivered by the buret. Use the density of the NaCl(aq) solution determined from the pipet data and the masses of each aliquot to calculate the “true” volume of each aliquot delivered. Calculate the % error in volume for each buret measurement. 17. Use the formula feature in Excel to calculate the requested quantities in table format and copy and paste your table into your Word document. . Chemistry 51 2023-2024 Page 32 DATA ANALYSIS AND LAB REPORT PREPARATION USING EXCEL AND WORD FOR USING COMMON LABORATORY EQUIPMENT LAB 18. To analyze the data from Part 2 of the “Using Common Lab Equipment” experiment you will have Excel calculate the concentrations of each of your red dye solutions from the stock concentration and dilution volumes and then create a scatter plot and perform a trendline fit to determine the Beer’s Law constant for the dye solution. 19. Create a results table in Excel to calculate the molarity of your diluted solutions. 20. Use the formula feature of Excel to complete the table entries for the molarity of solutions BE. 21. Type formula and sample calculations for this section into your Word document and then copy and paste your results table in as well. Don’t forget to put your equations on indented and sequentially numbered lines. 22. Back in Excel, click on “insert” and “charts” . Chemistry 51 2023-2024 Page 33 DATA ANALYSIS AND LAB REPORT PREPARATION USING EXCEL AND WORD FOR USING COMMON LABORATORY EQUIPMENT LAB Choose a scatter plot with no lines. While clicked on the chart, choose the “Chart Design” menu and then “Select Data.” Use the “add” or “remove” keys to have Excel plot one series of data. Use the “edit” key to set the x-axis and y-axis values for the chart. The x-axis should be the concentration values and the y-axis should be the absorbance values. 23. Format the plot in Excel by adding a chart title and axis titles. Use chart tools to adjust scaling, axis labels, etc. as necessary. Chemistry 51 2023-2024 Page 34 DATA ANALYSIS AND LAB REPORT PREPARATION USING EXCEL AND WORD FOR USING COMMON LABORATORY EQUIPMENT LAB 24. Add a linear trendline to your plot in Excel which will give a line that is a “best fit” to the data. Format the trendline to force a 0,0 intercept and display the R2 value and the equation of the line on the graph (make sure that the values displayed have at least 4 significant figures). The equation of the line represents the relationship between the concentration and absorbance values and can be used to calculate any other values lying on the line. The slope of the line in this case will be equal to the Beer’s Law constant for the dye. The R2 value gives a numerical value to how well the data points “fit” on the line (with 1.000 being the best fit, with all data points on the line). Chemistry 51 2023-2024 Page 35 DATA ANALYSIS AND LAB REPORT PREPARATION USING EXCEL AND WORD FOR USING COMMON LABORATORY EQUIPMENT LAB 25. If the highest concentration point is not “in line” with the other data points, add another series to the graph with that excludes this data point. Trendfit this new series to get a better equation of the line for the linear portion of the data. 26. Copy and paste your finished chart into your Word document in the results section. Don’t forget to add a caption to your plot. 27. Compare your experimental Beer’s Law constant from your graph to the “true” value given in the lab manual and calculate the % error. Show formulas and sample calculations on numbered lines as above. 28. Review your work for completeness before you turn it in. REFERENCES: Written by Janet Truttmann Spring 2022 Chemistry 51 2023-2024 Page 36 DATA ANALYSIS AND LAB REPORT PREPARATION USING EXCEL AND WORD OBJECTIVE(S): • • • • • • Practice spreadsheet data entry and display formatting with Excel Use formulas in Excel for repetitive calculations Plot scatter graphs from spreadsheet data in Excel Analyze graphical data Transfer Excel tables and graphs to a Word document for lab reports Enter formulas in Word using subscripts and/or superscripts and the equation editor INTRODUCTION: An important component of scientific work is the analysis and reporting of experimental results. In this activity you will review and build on the computing skills you learned in Chem 50. You will use the Excel spreadsheet program to make data and results tables, enter formulas for calculating experimental results from data, and create and analyze charts. You will transfer your Excel tables and charts to a Word document as you would for a lab report. Finally, you will use the equation editor feature of Word to type chemical equations and mathematical formulas/expressions. It is expected that students are able to perform the basic Excel functions that were covered in Chem 50. Students should review the Excel tutorial which is contained in the introduction section of the lab manual before attempting this activity if necessary. Instructions are only provided for “new” procedures. Please note that different versions of the Excel software have slightly different procedures for some tasks, so use the help feature in Excel to clarify any procedures if necessary. Also, make sure to bring a flash drive to class for saving your work and save early and often. PRE-LAB QUESTIONS: 1. Perform the following calculations using a calculator, and report the answers to the appropriate significant figures. Briefly state the sig fig rounding “rule(s)” or order of operations “rules” that influence(s) how you report each answer. a. 55.1045 + 0.000076 + 92.4 = ? b. (81.254 x 0.761) / (12.2 x 8.9945) = ? c. (14.527 – 11.4) x 13.00 x 6.3392 = ? 2. How would a spreadsheet formula be entered that will calculate: a. the value in cell B3 divided by the value in cell C3? b. the product of the values in cells A2 and B2? c. the sum of values that extend from cell A1 to cell A10 in a spreadsheet? d. the average of all the values in cells from C5 to C9? 3. What is an absolute cell reference and how do you designate an absolute cell reference? 4. What is a linear trendline? What other related information can be displayed along with the trendline? Revised 07/05/19 Chemistry 51 2023-2024 Page 37 DATA ANALYSIS AND LAB REPORT PREPARATION USING EXCEL AND WORD CHEMICALS AND MATERIALS student flash drive scientific calculator EQUIPMENT TO BE CHECKED OUT computer SAFETY none WASTE DISPOSAL none PROCEDURE: Part 1 – Spreadsheet data and formula entry In part 1, you will use Excel to process a set of titration data and create a Word document containing your data tables, sample calculations, and results tables. 1. Check out a computer from the professor. Power ON the computer, and launch the Excel and Word software programs. Keep a flash drive handy for file storage. Save the files often during work. 2. Create a data table in Excel with the following format and data. Use the “increase/decrease decimals” tool or the “format number” tool to force Excel to show the correct significant figures on all your data. Table 1: Titration Data Mass unknown acid titrated (g) Initial volume buret (mL) Final volume buret (mL) Molarity base (M) Trial 1 0.1042 1.45 10.87 0.1020 Trial 2 0.1102 1.32 11.24 0.1020 Trial 3 0.1055 1.58 11.15 0.1020 Trial 4 0.1121 2.07 11.98 0.1020 3. Open up a Word file and copy and paste your table into the Word document. Type your name in the header of the document. In the future, you will be asked to embed tables and graphs created in Excel into your Word document lab reports. 4. While in your table in Word, use the “merge cells” tool to merge and center your table title. (see below) Chemistry 51 2023-2024 Page 38 DATA ANALYSIS AND LAB REPORT PREPARATION USING EXCEL AND WORD Table 1: Titration Data Trial 1 Trial 2 Mass unknown acid titrated (g) 0.1042 0.1102 Initial volume buret (mL) 1.45 1.32 Final volume buret (mL) 10.87 11.24 Molarity base (M) 0.1020 0.1020 Trial 3 0.1055 1.58 11.15 0.1020 Trial 4 0.1121 2.07 11.98 0.1020 5. The formulas and sample calculations needed to process the above data are shown below. Copy the formulas and sample calculations below in your Word document using the Word Equation Editor as needed. volume base added = final volume buret – initial volume buret = 10.87 mL – 1.45 mL = 9.42 mL (1) moles base added = (volume base added)(molarity base) (2) =( 9.42ππΏ ππππ» 10−3 πΏ )β( 1 ππΏ 0.1020 πππππ ππππ» )β( πΏ ) = 9.608π₯10−4 πππππ ππππ» moles acid titrated = moles base added = 9.608π₯10−4 πππππ ππππ» added molar mass acid = = πππ π ππππ π‘ππ‘πππ‘ππ πππππ ππππ π‘ππ‘πππ‘ππ (3) (4) 0.1042 π π»π΄ 9.608 π₯10−4 πππππ π»π΄ π = 108.4 ππππ Chemistry 51 2023-2024 Page 39 DATA ANALYSIS AND LAB REPORT PREPARATION USING EXCEL AND WORD 6. Switch back to your Excel document and create a results table in Excel with the following format. Table 2: Titration Results for Molar Mass Trial 1 Trial 2 Trial 3 Trial 4 Volume base added (mL) Moles base added Moles acid titrated Molar mass acid (g/mole) 7. Use Excel formulas to calculate the values for Table 2 according to the data in Table 1 and the sample calculations shown above. Your formulas should reference the data values in Table 1. Your instructor will ask to see your formulas to make sure that they are entered correctly. Once you’ve entered the formulas for Trial 1, you can use the “copy/paste” or “drag and drop” feature of Excel to calculate the results values for Trials 2-4. 8. Copy and paste Excel Table 2 into your Word document and format it as was done for Table 1. 9. Type the following formulas into your Word document after Table 2. The true molar mass of the unknown acid is 107 g/mole. (Note that the Μ function can be found in the accent menu of equation editor.) average molar mass = ∑(πππππ πππ π ππ π π‘πππππ ) π standard deviation of molar mass = √ % standard deviation = Μ Μ Μ Μ Μ Μ )2 ∑(πππ −ππ π π‘ππππππ πππ£πππ‘πππ ππ£πππππ π−1 β 100% error in molar mass = average experimental molar mass – true molar mass % error in molar mass = πππππ π‘ππ’π π£πππ’π β 100% (5) (6) (7) (8) (9) 10. Create a second results table in Excel with the following format and use the appropriate “average” and “standard deviation” formulas within Excel to calculate these quantities. (Use the stdev.s function) Chemistry 51 2023-2024 Page 40 DATA ANALYSIS AND LAB REPORT PREPARATION USING EXCEL AND WORD Table 3: Statistical Analysis of Titration Results Average molar mass (g/mole) Standard deviation of molar mass (g/mole) % standard deviation of molar mass Absolute error in molar mass determined (g/mole) % error in molar mass determined 11. Copy and paste Excel Table 3 into your Word document and format. Go back and enter sample calculations using your values for equations 5, 7 and 8. 12. After Table 3 in the Word document, type the following using the subscript/superscript features of Word as needed: “The unknown acid was determined to be (CH3)2CHCH2COOH which dissociates in water according to: (CH3)2CHCH2COOH(aq) ↔ H+(aq) + (CH3)2CHCH2COO -(aq) (10)” 13. Make sure that your name is on your Word document. Ask your instructor if you should print it out to turn in. Chemistry 51 2023-2024 Page 41 DATA ANALYSIS AND LAB REPORT PREPARATION USING EXCEL AND WORD Part 2 – Line Graphs 1. In this exercise, you will use Excel to create a titration plot. Enter the following information into a new spreadsheet: Table 1: Weak Acid Titration Data buret reading (mL) pH 0.37 4.28 1.42 6.64 2.50 7.02 3.82 7.34 5.16 7.63 6.29 7.91 6.90 8.11 7.61 8.44 7.93 8.69 8.14 8.99 8.26 9.32 8.31 9.58 8.41 10.35 8.54 10.97 8.67 11.21 9.33 11.7 9.41 11.74 10.41 12.01 11.41 12.16 2. When plotting a pH titration curve, the required information for the x-axis is the volume of titrant added, not the value read from the buret. Create a new results table in Excel that calculates the mL of NaOH(aq) added for this titration by subtracting the initial buret reading (i.e. 0.37) from each buret reading. Chemistry 51 2023-2024 Page 42 DATA ANALYSIS AND LAB REPORT PREPARATION USING EXCEL AND WORD Table 2: Weak Acid Titration Plot mL NaOH added pH 0.00 4.28 1.05 6.64 2.13 7.02 3.45 7.34 4.79 7.63 5.92 7.91 6.53 8.11 7.24 8.44 7.56 8.69 7.77 8.99 7.89 9.32 7.94 9.58 8.04 10.35 8.17 10.97 8.3 11.21 8.96 11.70 9.04 11.74 10.04 12.01 11.04 12.16 3. Select the entire set of cells with numbers above to set the Data Range. Insert a scatter plot (choose the icon with smoothed lines and markers), with volume data as the horizontal (x) axis and pH data as the series (y) axis. [Titration curves are one of the few times you will choose this type of plot. For data that is expected to show a linear trend, you will use just a scatter plot with markers, as in Part 3]. 4. Format the chart to show minor tick marks (no gridlines and no background color) on both axes every 0.1 units, and set minimum/maximum axis values to just outside the data values. 5. Label each axis and title the graph. 6. Use the Insert Shapes tool to insert two lines as shown in the following graph. The vertical line should touch the axis at 4.00 mL and extend upward to the curve, and the horizontal line should indicate the pH value at 4.00 mL added by extending all the way to the y axis. If necessary, use the View icon to zoom in so that you can read the value where the line crosses the y-axis to the 0.1 level. Copy and paste your chart into a Word document. 7. Add a textbox to your Word document that indicates the pH of the titration when 4.00 mL of NaOH have been added (see Figure 1). Chemistry 51 2023-2024 Page 43 DATA ANALYSIS AND LAB REPORT PREPARATION USING EXCEL AND WORD 8. Make sure that your name is on your Word document. Ask your instructor if you should print out your Word document to turn in at the end of the period. pH vs. Volume of 0.100 M NaOH added for the Titration of an Unknown Weak Acid 13.0 12.0 11.0 pH 10.0 9.0 8.0 7.0 pH at 4.00 mL base added = 7.47 6.0 5.0 4.0 0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 11.0 12.0 mL NaOH added Figure 1. Titration curve for unknown acid. Chemistry 51 2023-2024 Page 44 DATA ANALYSIS AND LAB REPORT PREPARATION USING EXCEL AND WORD Part 3 – Scatter Graphs and Trendlines For Part 3, you will create a standard absorbance plot (Beer’s Law plot) using measured absorbance values for solutions of known concentration. The slope of the resulting plot will be used to determine the concentrations of unknown solutions from measured absorbance values. 1. Enter the following data into a new spreadsheet. Be sure that Excel displays the appropriate significant figures. Table 1: Standard Solution Absorbances Concentration of Standard (M) Absorbance 0.000 0.000 0.200 0.324 0.300 0.488 0.400 0.650 0.500 0.796 0.600 0.944 0.800 1.256 1.000 1.473 1.200 1.641 1.400 1.723 2. Select the data and insert an XY Scatter chart (markers only, no line) for the data in Table 1 with Concentration data as the horizontal (x) axis and Absorbance data as the Series (y) axis. Label each axis and title the graph. 3. Beer’s Law states that the absorbance of a solution is directly proportional to concentration (A = bC). A linear relationship is generally observed for absorbance values < 1. However, as solution concentrations increase and absorbance values increase, nonlinear behavior can be seen. In this example, we want to add a trendline to just the early linear portion of the data (first 6 points only). To do this, add a second series plotting just the first 6 points on the same graph. − While clicked on the plot, choose the “Select Data”. − A new window will pop up. Click on the “Add” Series button which will bring up yet another new window. − From here, click on the “Series X Values” bar and then highlight the six x values that you want to use for your linear trend fit. − Repeat for the y values. − Clicking “OK” twice should take you back to the plot with a second series of points added that overlaps the first. You can choose to make the markers “none” for this second series so that they don’t affect the appearance of the plot. 4. Add a linear trendline to this second series, which will give a line that is a “best fit” to the data. Format the trendline to force a 0,0 intercept and display the R2 value and the equation of the line on the graph (make sure that the values displayed have at least 4 significant figures). The equation of the line represents the relationship between the concentration and Chemistry 51 2023-2024 Page 45 DATA ANALYSIS AND LAB REPORT PREPARATION USING EXCEL AND WORD absorbance values, and can be used to calculate any other values lying on the line. The R2 value gives a numerical value to how well the data points “fit” on the line (with 1.000 being the best fit, with all data points on the line). 5. Since we will also need the slope value for a future calculation, enter the heading “Slope of Beer’s Law Calibration” into a new data cell. In the adjacent cell, click on the fx button at the top of the toolbar and search for and select the LINEST function. Clicking OK will take you to a window in which you can choose the known y values and the known x values from your first six data points. In the “Constant” box, enter 0 to indicate that you want the trendline fit to force a zero intercept. The calculated result should match the slope value displayed in the equation of the line on your plot. Beer's Law Plot of Standard Solutions 2.0 1.8 Absorbance 1.6 1.4 1.2 1.0 y = 1.5951x R² = 0.9993 0.8 0.6 0.4 0.2 0.0 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 Concentration of Standards (M) Figure 2. Beer’s Law Plot 6. The trendline equation (or calculated slope) can now be utilized to determine the unknown concentrations of solutions whose absorbances are known. Create a results table in Excel with the following: Chemistry 51 2023-2024 Page 46 DATA ANALYSIS AND LAB REPORT PREPARATION USING EXCEL AND WORD Table2: Unknown Concentrations Solution # Absorbance 1 0.550 2 0.224 3 0.873 4 0.758 Concentration (M) 7. Use the cell with the calculated slope of the standard plot to determine the concentration each of the unknown solutions 1 through 4. Enter a formula to calculate the concentration of solution 1, and then use Excel’s “copy/paste” or “drag and drop” feature to analyze the remaining solutions. 8. Copy and paste your chart and Tables 1 and 2 into your Word document and format as appropriate. Include formulas and sample calculations as shown in Part 1. Make sure that your name is on your Word document. Ask your instructor if you should print out your results to turn in. REFERENCES: Written by Janet Truttmann Spring 2015, revised 7-5-19 Chemistry 51 2023-2024 Page 47 DATA ANALYSIS AND LAB REPORT PREPARATION USING EXCEL AND WORD [this page intentionally blank] Chemistry 51 2023-2024 Page 48 KINETICS OF THE ACETONE TRIIODIDE REACTION BY THE INITIAL RATES METHOD OBJECTIVES: • Use colorimetry to follow the rate of a chemical reaction • Determine the rate law for a reaction using the initial rates method • Quantify the effect of a catalyst on the reaction rate • Relate an experimentally determined rate law to a proposed reaction mechanism (optional) INTRODUCTION: The purpose of this experiment is to study the kinetics of the reaction of triiodide with acetone in the presence of an acid catalyst using the initial rates method. The overall reaction is shown below (Equation 1). The initial rate of the reaction under different concentration conditions will be monitored using colorimetry. The triiodide ion absorbs light in the blue region of the visible spectrum (solutions appear yellow). According to Beer’s Law, absorbance is proportional to concentration (see techniques section on spectrophotometry in the beginning part of this manual). Therefore, the absorbance vs. time data collected in this experiment can be converted to concentration vs. time graph using Beer's Law. The initial rate of each reaction can then be determined by finding the negative of the initial slope of the triiodide concentration vs. time plot. By comparing reactions at different concentrations, the order of the reaction with respect to each reactant (and the catalyst) can be determined. The experimentally determined rate law may then be compared to the rate law predicted by a proposed reaction mechanism to see if they are consistent. + H I3− β―β― β―→ CH3COCH2I CH3COCH3 + acetone (colorless) triiodide (yellow) + H+ + 2I- (1) iodoacetone (colorless) The theory of initial rates can be found in your textbook in the kinetics chapter and has been discussed in class. You should review this material before beginning this experiment. Note: remember to bring a flash drive to lab so that you can save your data runs. Chemistry 51 2023-2024 Page 49 KINETICS OF THE ACETONE TRIIODIDE REACTION BY THE INITIAL RATES METHOD PRE-LAB QUESTIONS: 1. Read the following sections from the “Techniques” section of the laboratory manual: “Reading Analog Scales,” “Graduated Pipets,” and Spectrophotometry and Beer’s Law.” 2. In this experiment, we will use colorimetry to monitor the rate of the reaction by measuring the absorbance of the solution as a function of time. Which law allows us to convert measured absorbance to concentration? Which chemical species will be monitored using this method? 3. Express the rate of the reaction in terms of the change in concentration per time for each reactant and product (remember stoichiometry). 4. Refer to Table 1 in the procedure. a) Calculate the concentrations of KI3, acetone, and HCl in the final mixtures for experiments 1 through 4 (note that this is a “dilution” problem, and the final solution volume is the sum of all the volumes added). Expt. 1 2 3 4 [KI3] (M) [acetone] (M) [HCl] (M) b) Which initial concentration(s) are changing when experiments 1 and 2 are compared and which concentrations are held constant? c) How should the initial rate of the reaction change between experiment 1 and experiment 2 if the reaction is zero order in acetone? 1st order in acetone?, 2nd order in acetone? 5. The table below shows data from a similar experiment investigating the rate law for the dimerization of butadiene. 2C4H6(g) → C8H12(g) Experiment 1 Experiment 2 Time (sec) [butadiene] (M) Time (sec) [butadiene] (M) 0 0.0170 0 0.034 85 0.0167 150 0.0322 168 0.0164 305 0.0299 275 0.016 575 0.0266 425 0.0154 926 0.0235 604 0.0148 1367 0.0205 1002 0.0137 2047 0.0169 1500 0.0128 3489 0.0127 Chemistry 51 2023-2024 Page 50 KINETICS OF THE ACETONE TRIIODIDE REACTION BY THE INITIAL RATES METHOD a) Use Excel to graph the data from each experiment. For each experiment we want to consider only the initial rate (when the influence of the reverse reaction of products is negligible.) Are the plots of concentration versus time linear over the entire time? The initial rate should be determined from the first part of the graph that is linear (not just the first 2 points which may have significant error). In Excel, you can choose for which portion of data you want to perform a linear fit by plotting only this data as a second series on the graph and inserting a trendline for this series. Print your graphs including trendline fits to turn in. b) Determine the initial rate from each experiment and make an initial rates table similar to the one shown below. Use the method of initial rates to determine the reaction order for butadiene (e.g. zero, first, or second order). Note that these are experimental data and the numbers are not “perfect”. (Make sure you are using the method of initial rates and not integrated rates!) Initial Rates Table Experiment 1 2 [butadiene]0 (M) 0.017 0.034 Initial Rate (Ms-1) 6. One of the reactants in this experiment is acetone, which is an organic molecule. Organic molecules and their functional groups are discussed in chapter 20 of your textbook. a) Draw the Lewis structure of acetone. b) Draw the molecular shape of acetone and indicate the bond angles. c) List the polar bonds in acetone with their corresponding dipole vectors. Is acetone a polar molecule? d) What is the valence bond hybridization of each carbon atom in acetone? e) What functional group is present in acetone? Chemistry 51 2023-2024 Page 51 KINETICS OF THE ACETONE TRIIODIDE REACTION BY THE INITIAL RATES METHOD CHEMICALS AND MATERIALS 1.0 M acetone(aq) 2.5x10-3 M KI3(aq) 1.0 M HCl EQUIPMENT TO BE CHECKED OUT Pasco Spectrometer with 2 cuvettes Laptop 5 mL graduated pipet (4) Amber vial SAFETY Goggles must be worn at all times. WASTE DISPOSAL All reaction solutions should be disposed of in the labeled waste container in the hood. EXPERIMENTAL PROCEDURE: In this experiment, you will combine four solutions in varying amounts to determine the order of the reaction with respect to triiodide, acetone and H+. The aliquots of solution will be measured with graduated pipets. It is important to work cleanly and carefully and to mix the final solutions quickly because the reaction will begin as soon as the triiodide solution is added. Also, the acetone and KI3 solutions are somewhat volatile and the KI3 solution is light sensitive. To maintain the integrity of these solutions, take only small amounts out at a time and keep the stock bottles closed when not in use. Chemistry 51 2023-2024 Page 52 KINETICS OF THE ACETONE TRIIODIDE REACTION BY THE INITIAL RATES METHOD Instrument Set-Up 1. Obtain the check-out items from your instructor. 2. Place the laptop on one of the metal stands stored under the sink. Turn on the laptop and log in. Connect the USB end of the USB cable provided to a USB port on the laptop (A). Connect the small end of the USB cable into the port on the side of the Pasco Spectrometer (B). A B H E C D Figure 1. Pasco Spectrometer 3. Briefly press and hold the ON/OFF button on the side of the Spectrometer (C) next to the USB port to turn it on. After all three status LEDs (D) blink in sequence, release the ON/OFF button. The USB Status LED will shine green and stay lit. (Note: the Bluetooth Status LED will slowly blink blue. The Battery Status LED may also blink red to show that the battery is charging.) (Conversely, you can pair the device to the laptop using Bluetooth without the USB cable.) Chemistry 51 2023-2024 Page 53 KINETICS OF THE ACETONE TRIIODIDE REACTION BY THE INITIAL RATES METHOD 4. Open the Spectrometry application on the laptop . (If the icon is not on the task bar, use the Window’s search feature to locate the application. Note that this application is available for download for free from the Pasco Scientific website https://www.pasco.com for home use.) 5. The following screen (Figure 2) should appear on the laptop. Click on the Windows “square” at the top right of the screen to “maximize” the window. Make sure you are clicked on the ABSORBANCE/TRANSMITTANCE tab rather than Fluorescence. To toggle between the filled rainbow background and blank screen, click on the SHOW COLOR SPECTRUM icon (m) at the bottom of the screen. MAXIMIZE a b h i c j e d k l f g m Figure 2. Pasco Spectrometer Software Application Analyze Solution Screen and Icon Labels Chemistry 51 2023-2024 Page 54 KINETICS OF THE ACETONE TRIIODIDE REACTION BY THE INITIAL RATES METHOD 6. Click on the ANALYZE SOLUTION (b) from the menu at the top of the screen. 7. The Spectrometer next needs to be calibrated. The first calibration is a “dark” calibration. Cover the sample well with your finger to block ambient light from entering the detector. Then select CALIBRATE DARK (i) from the menu at the bottom of the screen. A check mark will appear when the calibration is complete. 8. Fill the reference cuvette about 3/4ths full with deionized water to use for the reference calibration. Handle the cuvette on the ribbed sides and wipe the smooth sides with a KimWipe. Insert the cuvette into the sample holder on the Spectrometer with the clear sides facing the white light source icon (E) on the Spectrometer (see Figure 1). Select CALIBRATE REFERENCE (j) from the menu at the bottom of the screen. A check mark will appear when the calibration is complete. Remove the reference cuvette and set aside. 9. In this experiment, we will be monitoring the loss of the colored I3- ion as a function of time. We first want to take an absorbance spectrum of this species to determine the best wavelength to monitor. Fill a second “sample” cuvette about 3/4ths full with the stock 2.5x10-3 M KI3 solution and place in sample holder as before. Select the RECORD circle (h) at the bottom left of the screen to start analyzing the solution. (The icon changes to a square while data is being collected.) After a few seconds, select the red STOP RECORDING square to stop data collection. 10. Select SCALE TO FIT (k) to rescale your data. 11. Click the ADD COORDINATE (l) icon to locate a wavelength to analyze on the curve. a) Move the cursor over the small box that appears connected to the text box. A small hand will replace your cursor. Drag the box slowly toward the curve. As you get near the curve, an arrow will appear that indicates a specific wavelength on the curve. Releasing the box will snap the box to the point on the curve the arrow is pointing to. b) Drag the box along the curve to find a desirable wavelength to analyze. For this experiment, choose 405 nm and then select the blue check mark next to the selected wavelength value to let the instrument know that this is the wavelength to monitor (if the check mark does not appear, try clicking on the text box). Record the chosen wavelength and measured absorbance value in your notebook. Remove the cuvette from the sample holder. 12. Select TIME (d) from the menu at the top of the screen. At this point, the instrument is ready to take kinetic data. Chemistry 51 2023-2024 Page 55 KINETICS OF THE ACETONE TRIIODIDE REACTION BY THE INITIAL RATES METHOD Solution Preparation 13. Label four clean, dry test tubes with “1.0 M acetone,” “1.0M HCl,” “2.5x10-3 M KI3,” and “DI water.” Measure 3 mL of the DI water with your graduated cylinder into the labeled test tube. Mark the level with a grease pencil and use this reference to obtain about 3 mL of each of the other solutions from the stock bottles to use for conditioning your pipets. Use a separate graduated pipet for each solution. Following the instructions in the "Review of Techniques" section on how to use a pipet, first condition each pipet with the appropriate solution. 14. Empty the above labeled test tubes to waste and obtain about 10 mL fresh of the acetone solution, HCl solution, and DI water to use in the trials. (10 mL is about half full.) You can leave the conditioned pipets in each labeled test tube. Obtain about 10 mL of fresh KI3 solution in the amber vial. Keep the lid closed on this vial when not in use. 15. Label two additional clean, dry 50-mL beakers with “A” and “B.” You will measure the required amount of the KI3 solution into beaker A according to Table 1. The required amounts of 1.0 M acetone, 1.0 M HCl, and DI water will be measured into beaker B prior to each trial. Exp. 1 2 3 4 # Trials 3 1 1 1 Table 1: Volumes of Solutions for Each Trial Beaker A Beaker B -3 2.5x10 M KI3 2.0 M Acetone 1.0 M HCl (mL) (mL) (mL) 2.50 1.00 1.00 2.50 3.00 1.00 2.50 1.00 2.00 5.00 1.00 1.00 DI H2O (mL) 3.50 1.50 2.50 1.00 Acquiring Kinetic Data 16. To begin each trial, prepare the solutions as described in step 15 and Table 1. Do not mix the contents of beakers A and B just yet. It is important to measure the volumes of solutions precisely as stated in Table 1. Be sure to record the exact measured values of the volumes into your laboratory notebook as you perform the experiment. 17. Read the directions for steps 18-20 before continuing. You should aim to mix and start scanning your solution within 20 seconds. 18. Pour the contents of beaker B into beaker A and then quickly swirl and pour entire contents back into beaker B and then one more time back into beaker A to help mix the solutions completely. 19. Quickly rinse the sample cuvette with a small amount of mixed solution to condition it and then fill it about 2/3rds full, wipe the outside of the cuvette with a Kimwipe and insert the cuvette into the spectrometer. Select START RECORDING (h) to begin Chemistry 51 2023-2024 Page 56 KINETICS OF THE ACETONE TRIIODIDE REACTION BY THE INITIAL RATES METHOD collecting absorbance vs. time data. Click on SCALE TO FIT (k) if necessary to see your data. 20. Collect data for about 1 minute. Select STOP RECORDING (h) to end the run. (The run may be stopped earlier if the absorbance stabilizes at a minimum value.) The absorbance should be decreasing with time in a fairly linear fashion (we are looking at initial rates). If this is not the case, ask your professor for assistance. 21. When the run is complete, a colored box will appear near the top of the graph with a label for that run. You can leave the name as “run 1” etc., or click on the box and use the pencil icon that appears to provide a new name (e.g. expt 1 trial 1). Record the name in your notebook along with the conditions of the run. 22. Rinse and dry beakers A and B for the next trial. Empty the contents of the sample cuvette to waste. Since you condition the cuvette before each run, it is not necessary to clean and dry the cuvette. 23. Repeat experiment 1 for a total of three trials to get an estimate of the precision of the initial rates. Remember to record the run name and conditions for each run in your notebook. 24. Complete all additional experiments according to Table 1, with only 1 trial for each additional experiment. 25. Use the EXPERIMENT OPTIONS (a) menu to save your experiment to your flash drive. (The saved file will have the extension .sp and can only be opened by the Pasco software. If you want to save the raw data in .csv format for analysis in Excel, use the SHARE (g) icon to export your data.) 26. Dispose of all solutions in the proper waste container. 27. Rinse all cuvettes with deionized water and dry the outside before returning to your instructor. 28. Turn off the Pasco Spectrometer and disconnect it from the laptop. Shut down the laptop. Return all items to your professor. (Note that if you need to take experimental data on a subsequent day, you can open the Pasco software and use the menu to open your previously saved experiment. You will still need to calibrate dark and light, but you can use your stored absorbance vs. wavelength file and proceed with new trials as before.) DATA ANALYSIS: 1. Calculate the initial concentrations of KI3, H+, and acetone for each experiment based on the stock concentrations and volumes mixed (see prelab question #4). Chemistry 51 2023-2024 Page 57 KINETICS OF THE ACETONE TRIIODIDE REACTION BY THE INITIAL RATES METHOD 2. Open the Pasco Spectrometry software on one of the department laptops (or go to the Pasco website and download the software onto your own device.) If you are not connected to a spectrometer, an error message will appear. Simply click on the X to close the message and then use the EXPERIMENT OPTIONS (a) icon to OPEN your saved file. 3. Again, click on the Windows “maximize” box if needed to reveal the entire software screen with lower icons. Use the SHOW COLOR SPECTRUM (m) to toggle off the rainbow background as desired. 4. Select the ANALYZE SOLUTION (b) icon on the upper menu to show the absorbance vs. wavelength plot. 5. Take a snapshot of the graph with the camera icon (f) in the upper right corner and then copy the snapshot to the clipboard using the COPY TO CLIPBOARD (q) icon. Paste the snapshot into a Word file and save for use in your report. 6. Using the absorbance and concentration values of the stock KI3 solution at the chosen wavelength, calculate the value of the Beer’s Law constant for the triiodide solution at the chosen wavelength. 7. Select the TIME (d) icon on the upper menu to show the absorbance vs. time plots for each of your trials. Take a snapshot of each of these data graphs for your lab report. Figure 3. Pasco Spectrometer Time Screen Chemistry 51 2023-2024 Page 58 KINETICS OF THE ACETONE TRIIODIDE REACTION BY THE INITIAL RATES METHOD 8. Enter the Beer’s Law constant determined in #5 as the slope in the blue box on the left of the screen (leave the y-intercept as zero). 9. Click on the Absorbance label on the y-axis of the graph until it reads “Concentration”. The graph will now show concentration vs. time for the selected run. 10. Click on SHOW LIVE SCAN DISPLAY (o) to toggle off the absorbance vs. wavelength spectrum box that appears on the screen. 11. You can adjust the axes of the graph by hovering the cursor over an axis until it turns into a double arrow and then scrolling up to expand the scale, or down to compress the scale. When the cursor is over the graph and is shaped like a hand, you can move the plot to show the region you choose (keeps same scaling). 12. Select the SHOW LINEAR FIT (n) icon from the menu at the bottom of the screen. The best fit line will appear on the screen along with a text box showing the equation of the line. 13. Use the SHOW SELECTION TOOL (p) to highlight the area of the plot that you want to fit. You should fit the first linear portion of the graph. Note how the values in the textbox on the screen change as you select different regions of the graph. 14. When you are satisfied with the fit, take a snapshot of the graph with the camera icon and copy the snapshot to the clipboard using the COPY TO CLIPBOARD (q) icon. Paste the snapshot into a Word file and save for use in your report. 15. Repeat for each run by selecting the run labels at the top of the screen. 16. Include all of the kinetic plots in your lab report. 17. Determine the precision of the experimental rates by calculating the standard deviation and percent standard deviation of the 3 repetitions of experiment 1. 18. Make an initial rates table that includes the initial mixed concentrations of all reactants (see prelab question #4) and the initial rate values from graphs of experiments 1-4. Use the data to determine the order of reaction with respect to acetone, triiodide, and H+. Use logarithms to solve for the exponent. Report the value of the exponent calculated and then round your results to the nearest whole number for use in your rate law. 19. Calculate a k value for each trial, the average k value, the standard deviation, and relative standard deviation. 20. Write the experimentally determined rate law for the reaction including the average k value. Chemistry 51 2023-2024 Page 59 KINETICS OF THE ACETONE TRIIODIDE REACTION BY THE INITIAL RATES METHOD POST-LAB QUESTIONS: 1. The purpose of performing multiple trials of experiment 1 is to assess the reliability of the measurements and to determine whether the variations observed within a given experiment are significant relative to the differences observed between experiments. a) State your average rate for experiment 1 and its range (low and high values) b) Use the average rate for experiment 1 to predict the rate for experiment 2 if the reaction were (i) zero order in acetone, (ii) first order in acetone, and if it were (iii) second order in acetone. c) Compare the predicted rates from part b to your range of data for experiment 1. Are the expected differences in rates significant relative to the variations observed within experiment 1? Can you use your data to reliably distinguish between zero, first and second order reactions? (Hint: does your range in “a” overlap your predicted rates in “b”?) 2. Why does the concentration of acid affect the rate of the reaction if H + is not a reactant? 3. What was the order of reaction with respect to the triiodide ion? What does this say about its role in the reaction mechanism (i.e. how does this limit which steps the triiodide ion can appear in)? 4. Using the rate law and rate constant you determined in the experiment, predict what the rate of the reaction would be under the following mixed concentration conditions: [HCl]o =0.400 M [acetone]o = 0.500 M [KI3]o = 0.00050 M 5. (optional post-lab activity) Your professor may choose to go over the proposed reaction mechanism with you in class and derive a rate law from the proposed mechanism. REFERENCES: Written by Janet Truttmann, February 2011, revised 7/05/19, revised 6/13/22 1. “Chemical Kinetics: Iodination of Acetone,” Patrick Duffy, Kwantlen Polytechnic University, Vancouver, Canada; http://www.kwantlen.ca/science/chemistry/faculty/pduffy/2310/labs/iodination.pdf 2. “Kinetics of the Iodination of Acetone,” Department of Chemistry, University of Idaho, Moscow, ID, 2010. 3. “Kinetics of Acetone/Iodine Reaction KI(order),” Tom Rybolt, University of Tennessee Chattanooga; http://www.utc.edu/Faculty/Tom-Rybolt/372LAB/Ex08KI-order.pdf Chemistry 51 2023-2024 Page 60 KINETICS ACTIVITY: INTEGRATED RATES METHOD OBJECTIVES: • Use the method of integrated rates to determine the order of reaction from concentration vs. time data • Use the Arrhenius equation and rate data at different temperatures to determine the activation energies of hypothetical reactions • Match determined rate laws to proposed reaction mechanisms • Draw reaction coordinate diagrams for proposed reaction mechanisms INTRODUCTION: The purpose of this activity is to analyze kinetic data for several hypothetical reactions in order to determine their rate laws, rate constants, and activation energies. We will use the method of integrated rates, which is described in your textbook. Remember that rate laws and rate constants for reactions must be determined from experimental data. The data provided in this activity is analogous to data that would be collected in a kinetics experiment. In order to use the integrated rates method, experimental data measuring the concentration of one of the reactants or products as a function of time is needed. Three graphs are made from each data set, - concentration vs. time - ln concentration vs. time - 1/concentration vs. time corresponding to the integrated rate equations for zero, first, and second order reactions respectively. The most linear graph of the three determines the order of the reaction with respect to the species studied. The linearity of the graphs can be judged visually and/or by comparing the R2 values of the linear trendlines. The closer the R2 value is to 1.000, the more linear the data. One experimental requirement of the integrated rates method is that the order for only one reactant at a time may be determined. For example, the hypothetical reaction A+B→C (1) would have a generic rate law of rate = k [A]x [B]y (2) In order to determine the reaction order for species A, the concentration of species B must be kept essentially constant throughout the experiment so that its influence on the reaction kinetics is not observed. This is accomplished by using a large excess of B in the experiment so that its concentration doesn’t change much as the reaction proceeds. The rate constants that are determined in this manner are called “pseudo” rate constants because they include the (Version 2) Chemistry 51 2023-2024 Page 61 KINETICS ACTIVITY: INTEGRATED RATES METHOD concentration of B. For example, if the graph of ln[A] vs time was the most linear with a slope of -45 s-1, the reaction would be first order in A and the pseudo rate constant, k’, would be 45 s-1. The rate law would then reflect only the dependence on A, with the nearly constant concentration of B imbedded into the pseudo rate constant, k’: rate = k’[A]1 (3) rate = 45 s-1[A]1 (4) Since the overall rate law and rate constant also depend on the order and concentration of B, rate = (k[B]y)[A]1 (5) the pseudo rate constant, k’, is k’ = k[B]y (6) Rearranging for the specific rate constant, k, is k = k’/[B]y (7) As described in your textbook, the rate constants for reactions are temperature dependent. The value of k increases with increasing temperature according to the Arrhenius Equation, k = Ae-Ea/RT (8) ln(k) = ln(A) – Ea/RT (9) or, where Ea is the activation energy of the reaction, A is the frequency factor, R is the ideal gas constant (8.3145x10-3 kJ/mole K), and T is the temperature in Kelvin. In order to determine the activation energy and frequency factor for a given reaction, rate constants for at least two different temperatures must be measured. If only two reaction temperatures are measured, the following equation is generally used to solve for Ea. ο¦k οΆ E ο¦1 1οΆ ln ο§ 1 ο· = - a ο§ ο· R ο¨ T1 T2 οΈ ο¨ k2 οΈ ο (10) The values of Ea, k and T can then be substituted back into either equation 8 or 9 to determine the value of A. If k values at several temperatures are measured, then an Arrhenius plot is made of ln(k) vs. 1/T according to equation 9. Equation 9 has the form of the equation of a line (y = mx + b) where ln(k) represents the y-axis data, 1/T represents the x-axis data, -Ea/R is the slope of the graph, and ln(A) is the y-intercept. Chemistry 51 2023-2024 Page 62 KINETICS ACTIVITY: INTEGRATED RATES METHOD πΈ slope = − π π ln(k) y-intercept = ln(A) 1/T (K-1) Figure 1: Arrhenius Plot Reaction Mechanisms and Reaction Coordinate Diagrams Chemical reactions generally occur in a series of steps called elementary steps. The sum of these steps gives the reaction mechanism. Elementary steps can be unimolecular (involve only one reactant) or bimolecular (involve the collision of two reactants). Termolecular collisions are extremely rare. Unlike overall reactions, the rate laws for elementary steps can be determined from the stoichiometry of that step. A→B (unimolecular) rate = k[A] (11) A+B→C (bimolecular) rate = k[A][B] (12) 2A → B (bimolecular) rate = k[A]2 (13) After the overall rate law for a reaction has been experimentally determined, reaction mechanisms can be proposed and tested. A valid reaction mechanism must meet the following criteria: 1. The sum of the elementary steps must add up to the overall reaction stoichiometry. 2. The mechanism must yield a rate law that is consistent with the experimentally determined rate law (see discussion below of rate-determining steps and fast equilibrium approximations). 3. The steps and intermediates proposed in the mechanism must make “chemical” sense and be consistent with additional isotopic labeling studies and spectroscopic studies that identify intermediates. The rate law for a proposed mechanism is determined from the rate law of the slow step. If the slow step is the first step of the mechanism, then the rate law for the mechanism is the rate law from that slow step. However, if the slow step is later in the mechanism, it is likely that Chemistry 51 2023-2024 Page 63 KINETICS ACTIVITY: INTEGRATED RATES METHOD intermediate species will appear in the rate law of the slow step. Since intermediates do not appear in experimental rate laws, we need a way to remove their concentrations from the mechanistic rate law. If the steps preceding the slow step are presumed to be “fast” and to reach an equilibrium, the equilibrium approximation method can be used. Consider the following proposed mechanism: step 1 A+B↔C fast step 2 C+D→E slow The rate law suggested by this mechanism would be rate =k2[C][D] where k2 is used to indicate the rate constant for the second step. However, C is an intermediate species that does not appear in the overall chemical reaction. If we assume that step 1 of the mechanism reaches an equilibrium (equilibrium means that the rate of the forward reaction equals the rate of the reverse reaction), then we can also write: k1[A][B] = k-1[C] where we use k1 to represent the rate constant for the forward reaction of step 1 and k -1 to represent the rate constant for the reverse reaction of step 1. We can solve the above equation for [C] π [π΄][π΅] [C] = 1π −1 Plugging this expression for [C] into the rate law from step 2 gives π [π΄][π΅] rate = π2 ( 1π −1 )[D] Combining all of the various rate constants into one rate constant gives rate = k[A][B][D] which would be the mechanistic rate law for this reaction. A reaction coordinate diagram shows the relative energies of the system as the reaction progresses. The initial energy is that of the reactants and the final energy level represents the energy of the products. Each elementary step in the mechanism has an activation energy barrier, and energy minima between the reactants and products represent the energy levels of intermediates (species that do not appear in the overall reaction but are formed in one step of the mechanism and are consumed in a later step). A sample reaction coordinate diagram is shown in Figure 2 for a hypothetical exothermic reaction of A + B + D → E that follows a two-step mechanism as described above. Chemistry 51 2023-2024 Page 64 KINETICS ACTIVITY: INTEGRATED RATES METHOD Mechanism: step 1 A+B↔C fast step 2 C+D→E slow Ea (first step) A+B Ea (second step) Energy reactants οHrxn E products C+D Reaction Coordinate Figure 2: Sample Reaction Coordinate Diagram for an Exothermic Reaction The reaction is exothermic because the products have a lower energy than the reactants. The first step in the mechanism produces the intermediate species C, which does not appear in the overall reaction, but does play a role in the mechanism. The second step in the mechanism is the rate-determining step because it has the largest activation energy. PRE-LAB QUESTIONS: 1. Write the integrated rate law equations for reactions that are (a) zero order, (b) first order, and (c) second order in [A]. 2. Describe how you will determine the order of a reactant from the data given. 3. The following rate constants were measured for a particular reaction: k1 = 5.2 x 10-10 M-1s-1 at 300. K k2 = 7.3 x 10-9 M-1s-1 at 320. K a. Based on the units of the rate constant, what is the overall order of the reaction? Chemistry 51 2023-2024 Page 65 KINETICS ACTIVITY: INTEGRATED RATES METHOD b. What are the values of Ea and A for this reaction? c. What is the value of the rate constant at 350. K? Chemistry 51 2023-2024 Page 66 KINETICS ACTIVITY: INTEGRATED RATES METHOD DATA: 2D(aq) + E(aq) → F(aq) + G(aq) System 1: οH = (-) The following data was obtained when the reaction was run in the presence of excess E 2.00M). It had been previously determined that the reaction was zero order in E. Expt 1, T = 300. K Time(sec) 0 60 120 180 240 300 360 420 480 540 600 660 720 780 840 1000 [D] (M) 0.250 0.179 0.138 0.114 0.097 0.083 0.073 0.066 0.060 0.055 0.050 0.047 0.043 0.041 0.038 0.033 ([E] = Expt 2, T = 315 K Time(sec) 0 15 30 45 60 75 90 105 120 135 150 165 180 195 210 [D] (M) 0.250 0.196 0.158 0.133 0.118 0.103 0.092 0.084 0.076 0.070 0.065 0.061 0.058 0.052 0.050 Expt 3, T = 325 K Time(sec) 0 10 15 20 25 30 35 40 45 50 55 60 65 70 Chemistry 51 2023-2024 [D] (M) 0.250 0.184 0.163 0.140 0.131 0.121 0.109 0.102 0.095 0.089 0.082 0.079 0.074 0.071 Page 67 KINETICS ACTIVITY: INTEGRATED RATES METHOD System 2: 2Z2(g) + 2XY(g) → 2Z2Y(g) + X2(g) οH = (+) The following data was obtained when the reaction was run in the presence of excess XY ([XY] = 2.00 M). It had previously been determined that the reaction is second order in XY. Expt 4, T = 500. K Time(sec) 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 System 3: Expt 5, T = 450. K [Z2] (M) 0.350 0.262 0.194 0.143 0.107 0.084 0.060 0.046 0.034 0.026 0.019 0.014 0.011 0.008 0.006 Time(sec) 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 πͺ L(aq) + Q(aq) → N(aq) + P(aq) [Z2] (M) 0.350 0.311 0.278 0.243 0.215 0.195 0.172 0.153 0.138 0.121 0.109 0.096 0.085 0.075 0.068 οH = (+) The following data was obtained when the reaction was run in the presence of excess Q ([Q] = 0.50M). It had previously determined that the reaction is first order in Q. The reaction is also facilitated by a catalyst, C, that was present at 0.010M. The reaction is first order in the catalyst C. Expt 6, T = 298 K Time(sec) 0 20 40 60 80 100 120 140 160 180 200 220 240 260 [L] (M) 0.05 0.047 0.045 0.042 0.039 0.038 0.034 0.031 0.028 0.026 0.023 0.02 0.018 0.015 Chemistry 51 2023-2024 Page 68 KINETICS ACTIVITY: INTEGRATED RATES METHOD DATA ANALYSIS: Ask your instructor what you should print out for your report. System 1: 2D(aq) + E(aq) → F(aq) + G(aq) οH = (-) (reaction run in presence of excess E; reaction is zero order in E, [E]o = 2.00M) 1. Write a generic rate law for this reaction (with variables for the orders). 2. Enter the data for system 1 into an Excel spreadsheet for the first reaction temperature studied. Make additional columns for ln [D] and 1/[D]. Use the formula function in Excel to calculate these quantities as a function of time. 3. Graph all three integrated rates plots for this reaction temperature as scatter plots (with unconnected points). Add a linear trendline to each graph that shows the equation of the line (with at least 4 significant figures on the slope) as well as the R2 value. 4. Repeat steps 2 and 3 for the other reaction temperatures studied. 5. Use the R2 values to select the correct plot for determining the order of reaction with respect to D. Write the final rate law for this reaction, including the orders for all reactants. 6. Determine the values of the pseudo rate constant, k’, for this reaction at each temperature from the slopes of the most linear plots (only) and include units on your values. Calculate the value of the specific rate constant, k, at each temperature for these runs (only) including units. 7. Make an Arrhenius plot using the specific rate constants determined in 6 and the reported temperatures. Determine the values of the activation energy and frequency factor, A, including units for this reaction from your graph. 8. Calculate the expected value of the specific rate constant, k, including units at 350. K. System 2: 2Z2(g) + 2XY(g) → 2Z2Y(g) + X2(g) οH = (+) (reaction run in presence of excess XY; reaction is second order in XY, [XY]o = 2.00M) 9. Write the generic rate law for this reaction. 10. Enter the data for system 2 into an Excel spreadsheet for the first reaction temperature studied. Make additional columns for ln [Z2] and 1/[Z2]. Use the formula function in Excel to calculate these quantities as a function of time. 11. Graph all three integrated rates plots for this temperature as scatter plots (with unconnected points). Add a linear trendline to each graph that shows the equation of the line (with slope to at least 4 significant figures) as well as the R2 value. Chemistry 51 2023-2024 Page 69 KINETICS ACTIVITY: INTEGRATED RATES METHOD 12. Repeat steps 10 and 11 for the other reaction temperatures studied. 13. Use the R2 values to select the correct plot for determining the order of reaction with respect to Z2. Write the final rate law for this reaction, including the orders of all reactants. 14. Determine the values of the pseudo rate constants, k’, including units for this reaction at each temperature from the slopes of the most linear plots. Calculate the value of the specific rate constant, k, including units at each temperature. 15. Use the two-point Arrhenius equation to determine the values of the activation energy and frequency factor, A, for this reaction. System 3: πͺ L(aq) + Q(aq) → N(aq) + P(aq) οH = (+) (reaction run in presence of excess Q; reaction is first order in Q, [Q]o = 0.50M, reaction is first order in C, [C]o = 0.010M) 16. Write a generic rate law for this reaction. 17. Enter the data for system 3 into an Excel spreadsheet. Make additional columns for ln [L] and 1/[L]. Use the formula function in Excel to calculate these quantities as a function of time. 18. Graph all three integrated rates plots as scatter plots (with unconnected points). Add a linear trendline to each graph that shows the equation of the line (with slope to at least 4 significant figures) as well as the R2 value. 19. Use the R2 values to select the correct plot for determining the order of reaction with respect to L. Write the final rate law for this reaction, including the order of all reactants. 20. Determine the value of the pseudo rate constant, k’, including units for this reaction from the slope of the most linear plot. Calculate the value of the specific rate constant, k, including units. Chemistry 51 2023-2024 Page 70 KINETICS ACTIVITY: INTEGRATED RATES METHOD POST-LAB QUESTIONS: Reaction Mechanisms and Reaction Coordinate Diagrams System 1: 2D(aq) + E(aq) → F(aq) + G(aq) οH = (-) 1. The following mechanism has been proposed for the reaction described in system 1. π1 step 1 D+D → I step 2 π2 I+E → F+G a. Show that this mechanism agrees with the overall reaction by adding the 2 steps together. What is/are the intermediates in this mechanism? b. Which step in the mechanism must be the rate-determining step in order for the proposed mechanism to agree with the experimentally determined rate law? c. Draw a reaction coordinate diagram based on the proposed mechanism that shows the relative energies of the reactants and products and the relative heights of the activation energy barriers for each step. System 2: 2Z2(g) + 2XY(g) → 2Z2Y(g) + X2(g) οH = (+) 2. The following reaction mechanism has been proposed for this system. π1/ π−1 step 1 2XY(g) ↔ step 2 Z2(g) + X2Y2(g) → X2Y(g) + Z2Y(g) step 3 X2Y(g) + Z2(g) → X2(g) + Z2Y(g) X2Y2(g) fast π2 π3 slow fast a. Show that this mechanism agrees with the overall reaction. intermediates in this mechanism? What are the b. Derive the rate law from this proposed mechanism. Does it agree with the rate law determined from the experimental data provided? c. Draw a reaction coordinate diagram based on the proposed mechanism that shows the relative energies of the reactants and products and the relative heights of the activation energy barriers for each step. Chemistry 51 2023-2024 Page 71 KINETICS ACTIVITY: INTEGRATED RATES METHOD System 3: πͺ οH = (+) L(aq) + Q(aq) → N(aq) + P(aq) 3. The following reaction mechanism has been proposed for this system. π1/ π−1 step 1 Q(aq) + C(aq) ↔ step 2 π2 S(aq) → M(aq) + C(aq) slow step 3 π3 M(aq) + L(aq) → N(aq) + P(aq) fast S(aq) a. Show that this mechanism agrees with the overall reaction. intermediates in this mechanism? fast What are the b. Derive the rate law from this proposed mechanism. Does it agree with the rate law determined from the experimental data provided? c. Why is C considered a catalyst in this mechanisms rather than an intermediate? d. Draw a reaction coordinate diagram based on the proposed mechanism that shows the relative energies of the reactants and products and the relative heights of the activation energy barriers for each step. e. The catalyst facilitates the transformation of Q to M by breaking this process into 2 steps. What must be true about the activation energies of these two steps relative to the uncatalyzed step Q → M? f. If a reaction is zero order in a certain reactant, what does that say about the role of that reactant in the reaction mechanism (i.e. where can it occur in the mechanism) ? REFERENCES: Written by Janet Truttmann, June 2011 (Version 2 written June 2014, revised 04/11/2020) Chemistry 51 2023-2024 Page 72 EQUILIBRIUM OF A METAL COMPLEX ION OBJECTIVES: • Determine the effects of various changes on a system at equilibrium (Le Chatelier’s Principle) • Use spectrophotometry and Beer’s Law to determine the concentration of pentaaquathiocyanatoiron(III), [Fe(H2O)5(SCN)]2+, in solution • Determine the value of the equilibrium constant, Keq, for the pentaaquathiocyanatoiron(III) complex formation reaction at two different temperatures INTRODUCTION: In this experiment, we will be studying the reaction of the iron(III) ion with the thiocyanate ion to form the red-colored complex ion pentaaquathiocyanatoiron(III), [Fe(H2O)5(SCN)]2+. As we will learn later, the Fe3+ ion in water is actually better represented as a complex ion with 6 water molecules attached to the central iron, [Fe(H2O)6]3+(aq). The SCNion replaces one of the water molecules attached to the Fe3+ in the following reaction. [Fe(H2O)6]3+(aq) + SCN-(aq) ο [Fe(H2O)5(SCN)]2+(aq) + H2O(l) οHo (-) (1) light yellow colorless red This reaction is often written using a shorthand notation that omits the attached water molecules. Fe3+(aq) light yellow + SCN-(aq) ο Fe(SCN)2+(aq) colorless (2) red The first part of the experiment is qualitative. You will prepare a solution containing the ions at equilibrium and explore the effects that various changes have on the equilibrium position of this system. Le Chatelier’s Principle states that when a system at equilibrium is disturbed, the reaction will proceed in a direction that tends to “undo” the disturbance. The changing conditions that we will investigate may include: - increasing the concentration of a reactant (οR) increasing the concentration of a product (οP) decreasing the concentration of a reactant (ο―R) decreasing the concentration of a product (ο―P) increasing the temperature (οT) decreasing the temperature (ο―T) diluting the solution (decrease the concentrations of all reactants and products) (ο―Rο―P) These changes may cause the reaction to shift to either the left or the right to re-establish equilibrium. Since the iron thiocyanate complex has a deep red color, we can observe the shifts in equilibrium position by seeing whether a given change causes the system to appear more red or less red. Revised 3/24/22 Chemistry 51 2023-2024 Page 73 EQUILIBRIUM OF A METAL COMPLEX ION In one of the steps for Part 1, you will add AgNO3(aq) to the equilibrium mixture. Silver ions react with thiocyanate ions as shown below. Ag+(aq) + SCN-(aq) → AgSCN(s) (3) Thus, the addition of the silver ions will reduce the concentration of the thiocyanate ions in solution causing a shift to re-establish equilibrium. The second part of the experiment is quantitative. In the second part, you will experimentally determine the value of the equilibrium constant, Keq, for the above reaction at two different temperatures. The concentration of the red-colored complex ion can be determined by measuring the absorbance at specific wavelength using spectrophotometry. First, a set of solutions of known Fe(SCN)2+ concentration will be prepared and their absorbance measured to enable construction of a Beer’s Law plot. The slope of the Beer’s Law plot is the Beer’s constant that allows us to relate measured absorbance to Fe(SCN)2+ concentration. Next, solutions containing various initial concentrations of Fe3+(aq) and SCN-(aq) will be prepared and the equilibrium Fe(SCN)2+ concentration measured using spectrophotometry. The equilibrium concentrations of the reactants will be calculated from their initial concentrations using ICE tables. The equilibrium constant will be determined from the ratio of equilibrium concentrations according to the Law of Mass Action. Finally, since the value of the equilibrium constant depends on temperature, we will determine the equilibrium constant at a second temperature and see whether the change agrees with what we would expect based on Le Chatelier’s Principle. Review the relevant sections in your textbook for each part before attempting the pre-lab questions. Also review the sections in the lab manual on Spectrophotometry and Beer’s Law and Graduated Pipets. A more detailed discussion of applying Beer’s Law to “real” data is given in the text box below. Chemistry 51 2023-2024 Page 74 EQUILIBRIUM OF A METAL COMPLEX ION Beer’s Law Plot—to lock or not to lock the intercept? Beer’s Law states that the absorbance of a solution is directly proportional to the concentration of the absorbing species when measured at a specific wavelength. This law is generally written as A = bc where A is the absorbance, c is the concentration of the absorbing species, and b is the proportionality constant. This law assumes that the absorbance of the “blank” solution is 0. When fitting Beer’s Law data, it is therefore common to force or lock a zero intercept in the trendline equation so that the form of the trendline equation matches the traditional Beer’s Law equation. However, in the world of “real data,” things aren’t always so tidy. It can happen that the data show a linear dependence on concentration but have an “offset” or non-zero intercept. In this case, forcing a zero intercept leads to a poor fit of the data and it is better to allow the trendline to include a yintercept. The resulting equation will have the form Absorbance A = (slope)c + offset Concentration (M) To find the concentration of a solution based on its measured absorbance, you need to use c= π΄−ππππ ππ‘ π ππππ Absorbance It can also happen that the absorbance data show a non-linear dependence on concentration. This tends to happen at high solution concentrations. Concentration (M) If this happens, it is customary to fit only the first linear portion of the graph (dashed box) and to dilute any unknown samples until their measured absorbance values fall within this linear portion. Chemistry 51 2023-2024 Page 75 EQUILIBRIUM OF A METAL COMPLEX ION PRE-LAB QUESTIONS: Part 1: Le Chatelier’s Principle 1. Write the balanced chemical equation for the reaction we are studying and its corresponding equilibrium constant expression. 2. Refer to steps 2-7 of the Part 1 procedure to make a table like the one below. Fill in the boxes to show your predictions of the effects of each change of conditions on the position of equilibrium. (Your instructor may request that this be put in the notebook.) Test Tube # 1 2 Table 1: Predictions of Le Chatelier’s Principle Specific Generic Predicted Shift to Observation That Expt. Action Re-establish Will Confirm Step Equilibrium Hypothesis (ο R) , (ο P) , → o r ο¬ ( ) etc. control e.g. add KSCN 3 4 5 6 Part 2: Determination of the Equilibrium Constant 1. Write the balanced chemical equation for the reaction we will be studying in this experiment and its associated equilibrium constant expression. 2. What analytical technique will we be using to measure concentrations? Which species can we measure with this technique? 3. State Beer’s Law and define its terms. 4. Discuss the purpose of the Beer’s Law plot. 5. The following data were collected by a student preparing standards for a Beer’s Law plot of compound X. The solutions were made by diluting a stock solution that was 0.250 M in X. Solution 1 was prepared by pipetting 1.12 mL of solution X and 3.87 mL of water as shown in Table 2 and mixing. (Assume that the volumes are additive.) Chemistry 51 2023-2024 Page 76 EQUILIBRIUM OF A METAL COMPLEX ION Table 2: Beer’s Law Data for “X” Solution # Volume(mL) of Volume (mL) 0.250 M X H2O Abs 1 1.12 3.87 0.211 2 2.09 3.06 0.380 3 3.06 2.16 0.550 4 3.97 0.78 0.780 5 4.92 0 0.940 Determine the concentration of X in each of the 5 resulting solutions. Make a table showing the calculated concentration and the measured absorbance. Use this table to create a Beer’s Law plot (on Excel) with a linear trendline fit (select the option of forcing the trendline have a 0 intercept). Determine the value of Beer’s constant for X at this wavelength. What would be the [X] for a solution whose absorbance was 0.475? 6. For our experiment in lab, creating a standard absorbance curve will require solutions of known concentrations of Fe(SCN)2+, which will be prepared by mixing known amounts of Fe3+ with a large excess of SCN- and assuming that the reaction goes “essentially to completion”. Describe a way that you could experimentally test the validity of the assumption that the reaction has gone to completion. Note: remember to bring a flash drive to lab so that you can save your data runs. Chemistry 51 2023-2024 Page 77 EQUILIBRIUM OF A METAL COMPLEX ION CHEMICALS AND MATERIALS Part 1. Part 2. 0.10 M KSCN(aq) 1.0 M KSCN(aq) 0.10 M Fe(NO3)3(aq) 0.0025 M KSCN(aq) 0.10 M AgNO3 0.10 M HNO3(aq) hot plates 1.0x10-4 M Fe(NO3)3(aq) in 0.1 M HNO3(aq) ice 0.0025 M Fe(NO3)3(aq) in 0.1 M HNO3(aq) hot plates EQUIPMENT TO BE CHECKED OUT Part 1. Part 2. none 10-mL graduated pipet 5-mL graduated pipet (x3) pipet pump or bulb Pasco Spectrometer and 2 cuvettes laptop SAFETY Goggles must be worn in the laboratory. WASTE DISPOSAL Dispose of all solutions in the labeled waste container. EXPERIMENTAL PROCEDURE: Part 1: Le Chatelier’s Principle In this part of the experiment we will be making qualitative observations about the shift in equilibrium position when certain “stresses” are applied to the system. Take careful notes about the color of each solution before and after each addition or change (see Data Analysis section). It is important to note how the system changed, not just its final color—e.g. did the solution get more red or less red as a result of your action. Refer back to your pre-lab predictions while performing the experiment and note any discrepancies from what you expected. 1. Prepare a solution of Fe(SCN)2+ at equilibrium by adding 5 drops of 0.10 M KSCN and 5 drops of 0.10 M Fe(NO3)3 to a beaker containing 20 mL of deionized water. Read the labels on the stock solutions carefully to make sure that you are using the correct concentrations. The solution should have a light to medium orange color, not dark red. 2. Pour 3 mL of this mixed solution into each of 6 test tubes and label the test tubes 1-6. Test tube 1 will be the control test tube. 3. To test tube “2” add 1 mL of 0.10 M KSCN Chemistry 51 2023-2024 Page 78 EQUILIBRIUM OF A METAL COMPLEX ION 4. To test tube “3” add 1 mL of 0.10 M Fe(NO3)3 5. To test tube “4” add 5 drops of 0.10 M AgNO3 (note that silver ions form an insoluble compound with thiocyanate ions). 6. Heat test tube “5” in a hot water bath to about 45°C 7. Place test tube “6” in an ice water bath Part 2: Determination of the Equilibrium Constant In this part of the experiment, we will use spectrophotometry to determine the equilibrium concentrations of the Fe(SCN)2+ ion in solution. Since the Fe(SCN)2+ ion has a deep red color, it absorbs light in the green region of the electromagnetic spectrum. Beer’s Law allows us to use the absorbance of the solution to calculate the concentration of this ion. The equilibrium concentrations of the Fe3+(aq) ion and the SCN-(aq) ion will be calculated from their initial concentrations and stoichiometry. The equilibrium concentrations of all three ions will then be used to calculate the value of the equilibrium constant at two different temperatures. 2A Preparation of Standard Solutions for Beer’s Law Plot In order to use spectrophotometry to determine the concentration of Fe(SCN)2+ in an unknown solution, we first need to measure its Beer’s constant by making solutions of known Fe(SCN)2+ concentration and measuring their absorbance. However, since Fe(SCN)2+ exists in equilibrium with its constituent ions, how can we know the concentration of Fe(SCN)2+ in solution? We will borrow an idea of Le Chatelier to help us out. By using a large excess of the SCN-(aq) ion, we can “drive the reaction essentially to completion” and therefore “know” the concentration of the Fe(SCN)2+ ion, since Fe3+ is the limiting reactant in the reaction. Once we have determined a value for the Beer’s constant for Fe(SCN)2+ from the Beer’s Law plot, we can use this to determine the equilibrium concentrations of Fe(SCN)2+(aq) in solutions of unknown concentration (and unknown equilibrium positions). Prepare all of the solutions shown in Table 3 for Part 2A before measuring their absorbance values (solutions need to be prepared and measured during the same lab period). 1. Use three small beakers to obtain approximately 30 mL each of 1 M KSCN, 20 mL of 0.10 M HNO3, and 15 mL of 1.0x10-4 M Fe(NO3)3 in 0.1M HNO3. Read the labels carefully to make sure you are getting the correct concentrations of each solution and be careful to take only the amount needed to avoid waste. Chemistry 51 2023-2024 Page 79 EQUILIBRIUM OF A METAL COMPLEX ION Table 3. Volumes of Reactants for Preparation of Standard Solutions for Beer’s Law Plot 1.0x10-4 M Fe(NO3)3(aq) Standard Solution # 1.0 M KSCN(aq) (mL) 0.10 M HNO3(aq) (mL) 1A 5.00 4.00 (mL) 1.00 2A 5.00 3.50 1.50 3A 5.00 3.00 2.00 4A 5.00 2.50 2.50 5A 5.00 2.00 3.00 in 0.1M HNO3 2. Pour off about 3mL of each of the above stock solutions into three separate labeled test tubes to use for conditioning your pipets. 3. Use conditioned 5-mL graduated pipets to make the solutions shown in Table 3. Add the specified volumes of each solution to five separate large test tubes (label with a grease pencil), stopper and mix thoroughly. These solutions use a large excess of KSCN and their absorbance will be used to construct the Beer’s Law plot. Your solutions should have a light to medium orange color (not dark red) and progress from lighter to darker (#1A-5A). (Note that the solutions are prepared in 0.1 M HNO3 to stabilize the Fe3+. The nitric acid prevents the iron(III) ions from precipitating as hydroxide salts, but does not otherwise participate in the reaction we’re studying.) 4. Ask your instructor if you should measure your Beer’s Law samples now (see 2C), or continue preparing solutions (2B) 2B Preparation of Sample Solutions for Determination of Equilibrium Constant 1. Prepare two large beakers of water to use as temperature baths for your Keq solutions. Leave one beaker at room temperature and heat the other on a hot plate to about 45°C. 2. Use three small beakers to obtain approximately 20 mL of 0.0025 M KSCN, 50 mL of 0.1 M HNO3, and 20 mL of 0.0025 M Fe(NO3)3 in 0.1M HNO3. Read the labels carefully to make sure you are getting the correct concentrations of each solution and be careful to take only the amount needed to avoid waste. 3. Pour off about 3mL of each of the above solutions into separate labeled test tubes to use for conditioning your pipets. Chemistry 51 2023-2024 Page 80 EQUILIBRIUM OF A METAL COMPLEX ION Table 4. Volumes of Reactants for Sample Solutions for Determining Keq Sample Solution # 1B 2B 3B 4B 0.0025 M KSCN(aq) (mL) 0.80 1.60 2.40 2.40 0.10 M HNO3(aq) (mL) 8.00 8.00 8.00 7.20 0.0025 M Fe(NO3)3(aq) (mL) 3.20 2.40 1.60 2.40 4. Use conditioned 10-mL and 5-mL graduated pipets to make the sample solutions shown in Table 4. Add the specified volumes of each solution to separate large test tubes (label with a grease pencil near the top of the test tube), stopper and mix thoroughly. Place the test tubes in the room temperature water bath. Make sure that the grease label stays above the water bath level or it may wash off. These solutions use comparable initial concentrations of Fe3+(aq) and SCN-(aq), and at equilibrium they will contain significant amounts of both reactants and products. We will use these solutions to determine the value of the equilibrium constant at two temperatures. Chemistry 51 2023-2024 Page 81 EQUILIBRIUM OF A METAL COMPLEX ION 2C Use of Spectrophotometry to Measure the Absorbance Values of the Solutions Instrument Set-Up 1. Connect the USB end of the USB cable provided to a USB port on the laptop (A). Connect the small end of the USB cable into the port on the side of the Pasco Spectrometer (B). A B H E C D Figure 1. Pasco Spectrometer 2. Briefly press and hold the ON/OFF button on the side of the Spectrometer (C) next to the USB port to turn it on. After all three status LEDs (D) blink in sequence, release the ON/OFF button. The USB Status LED will shine green. (Note: the Bluetooth Status LED will slowly blink blue. The Battery Status LED may also blink to show that the battery is charging.) 3. Open the Spectrometry application on the laptop. (If the icon is not on the task bar, use the Window’s search feature to locate the application. Note that this application is available for download for free from the Pasco Scientific website https://www.pasco.com for home use.) Chemistry 51 2023-2024 Page 82 EQUILIBRIUM OF A METAL COMPLEX ION 4. The following screen (Figure 2) should appear on the laptop. To toggle between the filled rainbow background and blank screen, click on the SHOW COLOR SPECTRUM icon (m) at the bottom of the screen. If you are unable to see the bottom menu, try clicking on the Windows “square” at the top right of the screen to “maximize” the window. a b h i c j d e k l f g m Figure 2. Pasco Spectrometer Software Application Analyze Solution Screen and Icon Labels 5. Click on the ANALYZE SOLUTION (b) from the menu at the top of the screen. 6. The Spectrometer next needs to be calibrated. The first calibration is a “dark” calibration. Cover the sample well with your finger to block ambient light from entering the detector. Then select CALIBRATE DARK (i) from the menu at the bottom of the screen. A check mark will appear when the calibration is complete. 7. Fill the reference cuvette about 3/4ths full with 0.1M HNO3 to use for the reference calibration. Handle the cuvette on the ribbed sides and wipe the smooth sides with a KimWipe. Insert the cuvette into the sample holder on the Spectrometer with the clear sides facing the white light source icon (E) on the Spectrometer (see Figure 1). Select Chemistry 51 2023-2024 Page 83 EQUILIBRIUM OF A METAL COMPLEX ION CALIBRATE REFERENCE (j) from the menu at the bottom of the screen. A check mark will appear when the calibration is complete. Remove the reference cuvette and set aside. Measuring the Beer’s Law Samples 8. In this experiment, we want to determine the concentration of the Fe(SCN)2+ ion by measuring it’s absorbance. We first want to take an absorbance spectrum of this species to determine the best wavelength to monitor. Condition and then fill the sample cuvette about 3/4ths full with solution 5A. Select the RECORD circle (h) at the bottom left of the screen to start analyzing the solution. (The icon changes to a square while data is being collected.) After a few seconds, select the red STOP RECORDING square to stop data collection. 9. Select SCALE TO FIT (k) to rescale your data. 10. Use ADD COORDINATE (l) to locate a wavelength to analyze on the curve. a) Move the cursor over the small box that appears connected to the text box. A small hand will replace your cursor. Drag the box slowly toward the curve. As you get near the curve, an arrow will appear that indicates a specific wavelength on the curve. Releasing the box will snap the box to the point on the curve the arrow is pointing to. b) Drag the box along the curve to find a desirable wavelength to analyze. This is usually a high point on the curve. (If your curve plateaus near the top of the graph, the absorbance is too large in that area to be used for analysis.) Choose the peak wavelength and then select the blue check mark next to the selected wavelength value to let the instrument know that this is the wavelength to monitor (if the check mark does not appear, try clicking on the text box). Record the chosen wavelength and measured absorbance value in your notebook. Remove the cuvette from the sample holder. 11. Select CONCENTRATION from the menu at the top of the screen. A table will appear on the left side of the screen that has columns for concentration and absorbance. 12. Calculate the concentration of the Fe(SCN)2+ ion in each of your prepared solutions 1A5A (recall that the Fe3+ ion is the limiting reactant) and enter those values in the table. Include a row for concentration = 0.00 mL. 13. With the 5A solution still in the spectrometer, click on the concentration row corresponding to this solution and select RECORD to measure the absorbance. When the absorbance reading stabilizes, select the check mark next to the absorbance to record the value. Record the absorbance value in your notebook. Chemistry 51 2023-2024 Page 84 EQUILIBRIUM OF A METAL COMPLEX ION 14. Condition and fill the cuvette with the next solution (1A) and place it in the Spectrometer. When the absorbance reading stabilizes, select the check mark next to the absorbance to record the value. Record the absorbance value in your notebook. 15. Continue with the remaining “A” solutions. 16. Re-insert the blank cuvette and measure and record a value for this solution as well. 17. Select STOP RECORDING when you are finished. 18. Use SCALE TO FIT to rescale your data. 19. Select SHOW LINEAR FIT to find and display the best fit line and equation. In the line fit text box, a lock icon can be used to set the y-intercept to zero if desired. Ask your professor if you should force a zero intercept on your Beer’s Law plot (*see textbox discussion below about the Beer’s Law equation and a trendfit line). Evaluate the linearity of your Beer’s Law plot. Re-make and re-measure any solutions that deviated significantly from the best fit line. When you are satisfied with your plot, record the concentration and absorbance values as well as the best fit equation of the line in your notebook. 20. .Use the camera icon to the clipboard using the use in your report. to take a picture of the Beer’s Law plot. Copy the snapshot icon. Paste the snapshot into a Word file and save for 21. Use EXPERIMENT OPTIONS to save your experiment to your flash drive. ASK YOUR INSTRUCTOR IF YOU SHOULD CONTINUE OR WAIT UNTIL THE NEXT LAB PERIOD. (If ending for the day, proceed to clean up in step 30.) Chemistry 51 2023-2024 Page 85 EQUILIBRIUM OF A METAL COMPLEX ION Measuring the Equilibrium Samples 22. In this part of the experiment, you will measure the absorbance of the “B” solutions at two different temperatures. If you haven’t already done so, place the “B” test tubes in a large beaker of room temperature water. Record the temperature in your notebook. Also use a hot plate to prepare a warm temperature water bath at about 45 °C for later. 23. Use a small amount of solution to condition the cuvette with solution 1B and then fill the cuvette about 3/4th full with this solution (don’t use more than half of the solution, because you will need to repeat this process at the higher temperature 24. If you measured your Beer’s Law samples today, skip to step 25. However, if you measured your Beer’s Law samples last lab period, repeat the instrument set-up steps (#17). then measure the absorbance vs. wavelength spectrum of solution 1B. Choose the same wavelength for analysis as for your Beer’s Law samples. 25. In the CONCENTRATION screen, select the box in the table titled DETERMINE UNKNOWN CONCENTRATION. 26. With solution 1B in the spectrometer, select the check mark next to the absorbance to record the value when the absorbance reading stabilizes. 27. Empty the cuvette to waste and continue with the next sample. Record the absorbance of each sample in your notebook. 28. Transfer the “B” sample test tubes to the warm water bath and let them equilibrate for at least 10 minutes. 29. Record the temperature of the warm water bath and re-measure each sample at the higher temperature. Work quickly to minimize heat loss to the environment. Record all absorbance values in your notebook. Clean up Procedures 30. Dispose of all solutions in the proper waste container. 31. Rinse all cuvettes with deionized water and dry the outside before returning to your instructor. 32. Turn off the Pasco Spectrometer and disconnect it from the laptop. Shut down the laptop. Return all items to your professor. Chemistry 51 2023-2024 Page 86 EQUILIBRIUM OF A METAL COMPLEX ION DATA ANALYSIS: Part 1: Le Chatelier’s Principle 1. Make a table like the one below to organize the results of your experiment. Your conclusions about the shift in equilibrium position should be based on your observations. Test Tube # Table X: Results of Le Chatelier Experiments Action Observation Conclusion (→ or ο) 1 2 3 4 5 6 2. Discuss any discrepancies between your original predictions and your final conclusions. 3. What effect did each action have on the value of the equilibrium constant? 4. Since neither silver ion nor nitrate ion appear in the balanced chemical equation for the reaction, why does the addition of silver nitrate affect the equilibrium position of this reaction? Part 2: Determination of the Equilibrium Constant The data analysis for this part of the experiment requires many repetitive calculations and is most conveniently performed using Excel spreadsheets. A sample spreadsheet organization for the Beer’s Law plot data is shown below. Determination of Beer’s Law Constant (Follow your instructor’s directions about whether to use the Beer’s Law plot generated in the spectrometry software or to create a new plot in Excel following the directions below.) 1. Calculate the concentration of Fe(SCN)2+ for each standard solution from Table 3 assuming that the complexation reaction goes to completion. Keep in mind that we are using a large excess of KSCN so the Fe3+(aq) ion is the limiting reactant. (Test tube “0” in the Excel example below is for the reference blank.) Chemistry 51 2023-2024 Page 87 EQUILIBRIUM OF A METAL COMPLEX ION Sample Format for Excel Spreadsheet for Standard Solutions for Beer’s Law Plot A Standard solution # 1 2 3 4 5 6 7 8 B Volume (mL) 1.0 M KSCN C D E Volume Volume Calculated (mL) (mL) Total -4 0.10 M 1.0x10 M Volume HNO3 Fe(NO3)3 (mL) F Calculated Fe(SCN)2+ (M) G Abs. 0 1 2 3 4 5 2. Make a plot of absorbance vs. concentration of Fe(SCN)2+ including the point for test tube “0”. Perform a linear fit on the data. You can use the options tab in the trendline menu to set the y-intercept to zero by forcing the line through the origin of the graph. Report the equation for the line including its R2 value. The slope of this graph is the Beer’s Law constant for Fe(SCN)2+ at this wavelength Determination of Equilibrium Constant In this part of the analysis, you will use the Beer’s law constant found above to determine the equilibrium concentration of the Fe(SCN)2+ species. (Once the reactants are mixed, the solution quickly comes to equilibrium and the measured absorbance of the solution is proportional to the final, equilibrium concentration of the Fe(SCN)2+ species.) Once the equilibrium concentration of the Fe(SCN)2+ species is known, the remaining equilibrium concentrations, and thus the equilibrium constant can then be determined. 1. Design two new spreadsheets to calculate the Keq values for the sample solutions from Table 4. at the two different temperatures. Include columns for: - solution (test tube) # volumes of each reactant solution added total volume of mixed solution initial concentrations of all species before reaction measured absorbance of reaction solutions equilibrium concentrations of all species Keq 2. First, calculate the initial concentrations of all species in the mixed solution before any reaction has taken place (mixing only). 3. Use the absorbance of the solution and the Beer’s constant determined above to calculate the equilibrium concentration of the Fe(SCN)2+ (aq) ion in each sample solution. Chemistry 51 2023-2024 Page 88 EQUILIBRIUM OF A METAL COMPLEX ION 4. Calculate the equilibrium concentrations of SCN-(aq) and Fe3+(aq) using ICE tables. 5. Calculate the Keq values for each sample solution. 6. Calculate an average value of Keq at each temperature and its corresponding standard deviation and relative standard deviation. 7. If the “true” value of the equilibrium constant at room temperature were 150, what would be your percent error? POST-LAB QUESTIONS: 1. How many significant figures should you report for your K values? Do all of your values agree within ± 1 in the last reported digit? What does that tell you about the precision of your results? 2. What does the magnitude of the experimental Keq tell you about the extent of this reaction at equilibrium? Compare your values for the equilibrium concentrations of reactants and products—do they support your conclusion? Why or why not? 3. How did the value of Keq change with temperature? Does this agree with your results from Part 1 of this experiment? Is the reaction of Fe3+(aq) with SCN-(aq) an endothermic or exothermic reaction? Explain. REFERENCES: Written by Janet Truttmann, April 2011, revised 3/24/22 “Determination of Keq,” Chemistry 1B Laboratory Manual Version 5.0, Fall 1997-Spring1998, Mt. San Antonio College Chemistry Department Chemistry 51 2023-2024 Page 89 EQUILIBRIUM OF A METAL COMPLEX ION [This page left intentionally blank.] Chemistry 51 2023-2024 Page 90 pH AND HYDROLYSIS OF SALT SOLUTIONS OBJECTIVES: • Predict and confirm whether a given aqueous salt solution is acidic, basic, or neutral using an indicator • Write hydrolysis equations for acidic and basic salts • Prepare salt solutions with a given molarity and volume from a solid and stock solution • Calculate the theoretical pH of the prepared salt solutions and compare to experimental pH values INTRODUCTION: Many ionic compounds, commonly known as salts, dissolve in water and dissociate partially or completely into anions and cations. This dissociation is due to the ability of the polar water molecules to surround and pull the ions away from the crystal lattice in a process called hydration. (See figure below). In chemical equations, we simply represent this as the dissociation of the solid salt into its constituent ions and leave out the water molecules that surround the ions. NaCl (s) Na+ (aq) + Cl– (aq) Hydrated cation Hydrated anion In some instances, the cation or anion (in some cases, both) reacts with the water molecule in a process known as a hydrolysis reaction. Hydrolysis reactions involve the transfer of hydrogen ions between the ion and water. If the hydrolysis reaction produces hydronium ions, the resulting solution is acidic. NH4+ (aq) + H2O (l) NH3 (aq) + H3O+ (aq) Chemistry 51 2023-2024 (acidic solution) Page 91 pH AND HYDROLYSIS OF SALT SOLUTIONS However, if the hydrolysis reaction produces hydroxide ions the resulting solution is basic. F– (aq) + H2O (l) HF (aq) + OH– (aq) (basic solution) If the anions and/or cations that do not undergo these hydrolysis reactions, the solution remains neutral. Thus a salt can be classified as neutral, acidic, or basic depending on what type of hydrolysis reaction it undergoes. In general, cations that hydrolyze water give rise to acidic solutions while anions that hydrolyze water give rise to basic solutions (see exception below). In the lab, the acidity or basicity of a solution can be observed one of two ways: using a pH meter or a pH indicator. Litmus papers are filter papers that have been soaked in litmus (a mixture of plant dyes extracted from lichens). Blue litmus paper will turn red in acidic solutions while red litmus paper will turn blue in basic conditions. To determine the pH of a solution more quantitatively, a pH meter can be employed to measure the hydronium ion concentration, [H3O+], of a solution. The following steps can be taken to predict whether a given salt solution is acidic, basic, or neutral: 1) Break the salt into its component ions (notice that the sum of the charges equals 0). Ex: Na2SO4 (s) 2Na+ (aq) + SO42– (aq) 2) Inspect the cation and anion to see whether they fall into the following categories. a. Cation: undergoes hydrolysis and produces an acidic solution if i. It is the conjugate acid of a weak base. Weak bases include ammonia (NH3) and amines (carbon groups replace one or more of the hydrogens in ammonia). Examples of conjugate acids of these weak bases include ammonium ion (NH4+), C2H5NH3+, CH3NH3+, etc. In the hydrolysis reaction of these cations, a hydrogen ion from the cation is donated to the water molecule, producing a hydronium ion. CH3NH3+ (aq) + H2O (l) CH3NH2 (aq) + H3O+ (aq) ii. It is a small, highly charged metal ion. These are most commonly transition metals with +2 or +3 charge (Zn2+, Fe3+, Cu2+, etc.) or Al3+ ions. Since these ions have a high charge density, they are strongly hydrated, meaning they have many Chemistry 51 2023-2024 Page 92 pH AND HYDROLYSIS OF SALT SOLUTIONS water molecules attached to them, and the ion–water combination behaves as a complex ion. The number of water molecules that hydrate the metal cation can vary. Al3+ (aq) + 6H2O (l) [Al(H2O)6]3+ (aq) Because of the strong interaction between the metal cation and water molecules, one of the O–H bonds in one of the water molecules surrounding the metal ion eventually breaks. The hydrogen is transferred as an ion to a nearby water molecule, and the complex metal ion now contains one less water molecule, a hydroxide ion, and a reduced ion charge. [Al(H2O)6]3+ (aq) + H2O (l) [Al(H2O)5 OH]2+ (aq) + H3O+ (aq) b. Anion: undergoes hydrolysis and produces a basic solution if i. It is the conjugate base of a weak acid and has no hydrogen atom “H” in the formula (see exception below). In the hydrolysis reaction, the anion pulls one of the hydrogen ions off from water, producing a weak acid and a hydroxide ion as shown below. NO2– (aq)+ H2O (l) HNO2 (aq) + OH– (aq) Exception: If the anion is the conjugate base of a weak acid and has a hydrogen atom “H” in its formula, it may produce either an acidic or basic solution, depending on the relative magnitude of its Ka and Kb values. If Kb > Ka, the hydrolysis reaction will produce a basic solution. HS– (aq) + H2O (l) H2S (aq) + OH– (aq) Kb = 1.1 x 10–7 HS– (aq) + H2O (l) S2– (aq) + H3O+ (aq) Ka = 1 x 10-19 If Ka > Kb, the hydrolysis reaction will produce an acidic solution. HSeO3– (aq) + H2O (l) H2SeO3 (aq) + OH– (aq) Kb = 4.2 x 10–12 HSeO3– (aq) + H2O (l) SeO32– (aq) + H3O+ (aq) Ka = 4.8x 10–9 3) If both the cation and the anion do not fall into the categories above, then neither ion will undergo hydrolysis, and the salt solution will be pH neutral. Typically the cation and anion are conjugates of strong acids and bases. NaCl (s) Na+ (aq) + Cl– (aq) (neither ion will undergo hydrolysis) 4) In cases where both the anion and the cation undergo hydrolysis, compare the Ka and Kb values to determine whether the solution will be acidic (Ka > Kb), basic (Ka < Kb), or neutral (Ka = Kb). For example, in NH4F (s), both the cation and anion undergo hydrolysis reactions. A comparison of the Ka and Kb values show that it will be an acidic solution. Chemistry 51 2023-2024 Page 93 pH AND HYDROLYSIS OF SALT SOLUTIONS NH4+ (aq) + H2O F– (aq)+ H2O NH3 (aq) + H3O+ (aq) Ka = 5.7 x 10–10 HF (aq) + OH– (aq) Kb = 2.9 x 10–11 Once the proper hydrolysis equation is written, the pH of the salt solution can be calculated. You can treat it as a weak acid/base equilibrium calculation problem and set up the ICE table and use the appropriate Ka or Kb values. Ex: Calculate the pH of a 0.125 M NaF solution. Look up the appropriate Ka or Kb value in the text. Solution: Of the two ions (Na+ and F–), only F– undergoes hydrolysis. Since it is the conjugate base of a weak acid, it will produce a basic solution. The balanced equation is written, showing the production of the hydroxide ion (OH–) and the Kb value is obtained from the text. F– (aq) + H2O Kb = 2.9 x 10–11 [F–] H2O (l) [HF] [OH–] Initial (M) 0.125 –– 0 ~0 Change (M) –x –– +x +x 0.125–x –– x x Equilibrium (M) Kb = ο HF (aq) + OH– (aq) [HF] [OH - ] (x) (x) = = 1.6 x 10 -11 [F ] (0.125 - x) [HF] [OH- ] (x) (x) Kb = = = 2.9 x 10-11 [F ] (0.125-x) x = [OH–] = 1.9 x 10–6 M pOH = 5.72 pH = 8.28 (basic as expected) Since weak acids ionize only slightly, the percent ionization can be determined by dividing the concentration of ionized acid at equilibrium by the initial concentration of the acid. The concentration of ionized acid is equal to the concentration of the hydronium ions at equilibrium and it can be substituted as shown below. Chemistry 51 2023-2024 Page 94 pH AND HYDROLYSIS OF SALT SOLUTIONS % πππππ§ππ‘πππ = [π»3 π+ ]πππ’ππ πππππππ‘πππ‘πππ ππ πππππ§ππ ππππ π₯ 100% = π₯ 100% ππππ‘πππ πππππππ‘πππ‘πππ ππππππ [π»π΄]ππππ‘ A similar equation can also be written for weak bases. % πππππ§ππ‘πππ = [ππ» − ]πππ’ππ πππππππ‘πππ‘πππ ππ πππππ§ππ πππ π π₯ 100% = π₯ 100% ππππ‘πππ πππππππ‘πππ‘πππ ππ πππ π [π΅]ππππ‘ From the previous example, 0.125M NaF solution resulted in [OH–] = 1.9 x 10-6 M. The percent ionization calculation is as follows: % πππππ§ππ‘πππ = [ππ» − ]πππ’ππ (1.9 π₯ 10−6 π) π₯ 100% = π₯ 100% = 0.0015% [π΅]ππππ‘ (0.125π) In Part 1 of the lab, you will first predict whether the aqueous solution of a given salt is acidic, basic, or neutral using the guidelines given in the Introduction and write the appropriate hydrolysis equations. You will then test your predictions by placing a drop of the solution on red and blue litmus papers and observing the color change. In Part 2 of the lab, you will quantitatively prepare two salt solutions with a given molarity and volume. In one case, you will be given a solid salt and in the other, you will be given a prepared stock solution. You will then determine the experimental pH value of the solutions using a pH meter and compare them with the calculated theoretical pH values. PRE–LAB QUESTIONS: 1. Determine whether the following cations will hydrolyze water. Explain your reasoning. a. Mn2+ b. K+ c. C6H5NH3+ d. Ba2+ 2. Determine whether the following anions will hydrolyze water. Explain your reasoning. a. NO2– b. HS– c. CN– d. Br– 3. The hydrogen oxalate ion, HC2O4–, can theoretically undergo both acidic and basic hydrolysis reactions. Write balanced chemical equations for both hydrolysis reactions. 4. Given the following values for HC2O4– (Ka = 6.4 x10–5 and Kb = 1.7 x 10–13) which reaction from above is favored? Would a salt solution of NaHC2O4 be acidic, basic, or neutral? 5. Write a short procedure (include type of glassware, calculations, etc.) for making 25.00 mL of a 0.0250 M NaF solution from a. solid NaF b. 0.100 M NaF solution 6. Calculate the % ionization of a 0.100M HF solution. Look up the Ka value in the text Chemistry 51 2023-2024 Page 95 pH AND HYDROLYSIS OF SALT SOLUTIONS CHEMICALS AND MATERIALS Part 1. Part 2. 0.10M Na2CO3 NH4Cl (s) 0.10M NaBr 0.250M Na3PO4 0.10M NaHSO3 pH 4, 7, and 10 buffers 0.10M NaH2PO4 0.10M CuSO4 0.10M Na3PO4 0.10M MgSO4 0.10M Fe(NO3)3 0.10M NaHCO3 EQUIPMENT TO BE CHECKED OUT Spot plate 25-mL volumetric flask + lid/stopper 5-mL graduated pipet Pipet pump Vernier pH sensor Laptop computer SAFETY Goggles must be worn in the laboratory. WASTE DISPOSAL Dispose used litmus paper in the trashcan. Dispose all used salt solutions and buffers in the chemical waste container. EXPERIMENTAL PROCEDURE: Part 1: Acidic, Basic or Neutral Salt 1. Make a table for water and the nine salt solutions (see the list in Chemicals and Materials) that you will be testing. An example is done for the first salt. Complete the table (except the last two columns) with your predictions. Once it is completed, have your professor approve it before starting the experiment. 0.1M solution Ions Ion(s) expected present in to hydrolyze solution H2O Hydrolysis reaction (if applicable) Type of solution H2O N/A N/A N/A Neutral Na2CO3 2Na+, CO32– CO32– CO32– (aq) + H2O (l) HCO3– (aq) – + OH (aq) Basic Chemistry 51 2023-2024 Color of Red Litmus paper Color of Blue Litmus paper Page 96 pH AND HYDROLYSIS OF SALT SOLUTIONS 2. Check out a spot plate and clean it thoroughly – be sure to do a final rinse with deionized water. Number the wells of the spot plate (1–10) using a grease pencil. 3. Squirt deionized water into well #1 so it is approximately ¼ full. Add about the same volume of salt solutions (see list in Chemicals and Materials) into wells #2–10. Avoid contamination - do not let the tip of the bottles touch the solutions or the spot plate. 4. Cut 5 pieces of red litmus papers into halves, giving a total of 10 pieces. Repeat with the blue litmus paper. Arrange the pieces of red and blue litmus paper on a piece of paper towel into two rows. (Note: check your blue litmus paper to see if it is still blue or has turned red since it tends to react with carbon dioxide in the air over time. See your instructor if your blue litmus paper is not blue.) 5. Dip a clean stirring rod into the well #1 and transfer a drop of DI H2O onto the red litmus paper. Transfer another drop onto the blue litmus paper. Record the colors of the litmus papers and check to see if it confirms your prediction. 6. Repeat step #5 for each salt solution. Be sure to rinse the stirring rod with DI H2O in between solutions to avoid contamination. Compare your results with your prediction as you go along. 7. All used litmus paper can be thrown into the trashcan. Pour the used salt solutions into the waste container. Clean and return the spot plate back to the Instructor. Part 2: pH of Salt Solutions 8. Check out a 25-mL volumetric flask with a lid, a 5-mL graduated pipet, a pipet pump, Go Direct pH sensor, and a laptop (Check with your professor to see if you will use a mobile device or a laptop). 9. You will prepare 25.00 mL of two salt solutions with the given molarity. The first solution will be prepared from a solid and the second one from a stock solution. Your instructor will give you the target molarity for each solution. 10. Calculate the mass of the salt or the volume of the stock solution needed to prepare the desired molarity of the two salt solutions. Write the procedure (including how to condition the pipet) for making the two solutions. 11. Predict whether the solution will be acidic, basic, or neutral. Write the appropriate hydrolysis reaction and calculate the theoretical pH of the salt solution (see example in the Introduction). 12. Check your calculations and procedures with your professor first before proceeding to make the solution. 13. Prepare the first solution––1A––(be sure to record the exact mass of the solid) using the volumetric flask. Transfer your solution to a clean, dry 125 mL Erlenmeyer flask and stopper to avoid evaporation loss. After each step, rinse the volumetric flask several times with tap water and finally with deionized water to prepare for the next solution. Chemistry 51 2023-2024 Page 97 pH AND HYDROLYSIS OF SALT SOLUTIONS 14. Repeat step 12 to prepare the second solution––2A––from the provided stock solution (be sure to record exact volume of the stock solution used). 15. Follow the directions provided to connect the Go Direct pH sensor to your laptop or mobile device. Calibrate the pH sensor (use a three-point calibration if measuring both acidic and basic solutions) and measure and record the pH of your salt solutions. 16. Dispose of all salt solutions in the chemical waste container. Clean all glassware and do a final rinse with deionized water. Check with your professor to see if you will be doing the Extension (Optional Procedure) below. If not, return all checked out items to your professor. EXTENSION (OPTIONAL PROCEDURE) In this part, you will prepare various solutions using serial dilution and measure the pH of those solutions. mL mL Solution 1A ¾2.00 ¾¾ ® Solution 1B ¾2.00 ¾¾ ® Solution 1C (original solution) mL mL Solution 2A ¾2.00 ¾¾ ® Solution 2B ¾2.00 ¾¾ ® Solution 2C (original solution) 17. Dilute your first solution (1A) by transferring 2.00 mL of solution 1A with your pipet to the rinsed volumetric flask and filling up to the mark with DI water. Pour this solution into a clean, dry Erlenmeyer flask and stopper. Label this solution 1B. 18. Make a dilution of solution 1B by transferring 2.00 mL of solution 1B to the rinsed volumetric flask and filling up to the mark with DI water. Pour this solution into a clean, dry Erlenmeyer flask and stopper. Label this solution 1C. 19. Dilute your second solution (2A) in the same way following steps 16-17. In other words make solutions 2B and 2C. 20. Measure and record the pH of solutions 1B, 1C, 2B, and 2C. Dispose of all salt solutions in the chemical waste container. Clean all glassware and do a final rinse with deionized water. Return all checked out items to your professor. Chemistry 51 2023-2024 Page 98 pH AND HYDROLYSIS OF SALT SOLUTIONS DATA ANALYSIS: Part 1: Acidic, Basic or Neutral Salt 1. Did the experimental results from Part 1 match your predictions? If no, list the salt(s) that did not match. 2. Write the equilibrium expression (specify Ka or Kb) for each hydrolysis reaction that occurred. Part 2: pH of Salt Solutions 3. Calculate the percent error between the calculated and the experimental pH for the solutions 1A and 2A you prepared in Part 2. 4. Use your measured pH of each solution to calculate the [H3O+], [OH–], and pOH of the salt solutions from Part 2. Show a sample of each type of calculation, and organize your data in a table. Extension (Answer these questions only if you performed the optional procedure as directed by your professor) 5. Calculate the initial concentrations of each of your diluted solutions (1B, 1C, 2B, 2C) from Part 2. 6. Use your measured pH values and initial concentrations to calculate the % ionization for each of the six solutions (1A, 1B, 1C, 2A, 2B, 2C) from Part 2. How did the % ionization change with dilution? Do your results agree with what you would predict based on Le Chatelier’s Principle? Explain. 7. Use ICE tables to help you calculate K values from the measured pH and initial concentrations of solutions 1A, 1B and 1C. Are the K values the same? Explain. Calculate an average K value, rel. std. dev. and % error for these solutions. 8. Use ICE tables to help you calculate K values from the measured pH and initial concentrations of solutions 2A, 2B and 2C. Are the K values the same? Explain. Calculate an average K value, rel. std. dev. and % error for these solutions. Chemistry 51 2023-2024 Page 99 pH AND HYDROLYSIS OF SALT SOLUTIONS POST–LAB QUESTIONS: 1. For each of the salts listed below, predict whether it is an acidic, basic, or neutral salt. Write the net ionic equation for the hydrolysis reaction to support your answer. a. NiCl2 b. Na2S c. NH4C2H3O2 d. Ba(NO3)2 2. Why was DI H2O tested in this experiment? 3. A student was preparing an acidic salt solution using a solid salt. How would the pH of the salt solution be affected (increase, decrease, or no change) if some solid salts were spilled on the bench top while it was being transferred into the volumetric flask? Explain your reasoning. 4. A student was preparing a basic salt solution by diluting from a stock solution of the salt. How would the pH of the salt solution be affected (increase, decrease, or no change) if the pipet was rinsed with distilled water but was not conditioned with the stock solution before use? Explain your reasoning. 5. Baking soda contains NaHCO3 (sodium hydrogen carbonate or sodium bicarbonate). A solution of baking soda can be ingested to alleviate acid indigestion. Based on what you learned from this lab, explain why it is an effective antacid. Include chemical equations in your explanation. 6. Calculate the pH of a 0.234 M NaHCO3 solution. Look up the appropriate Ka or Kb value. REFERENCES: Written by Jenny Leung, April 2011 (Reviewed and edited by Terri Beam and Janet Truttmann); Last updated 6/28/22 Figure of salt dissolution, courtesy of Kamran Golestaneh Ka and Kb values obtained from Chemistry, A Molecular Approach 1st edition, Nivalo J. Tro Chemistry 51 2023-2024 Page 100 PREPARATION AND PROPERTIES OF BUFFERS OBJECTIVES: • Design and prepare buffer solutions at a given pH and molarity • Investigate the effect of adding water, strong acid, and strong base on the pH of buffered and non-buffered systems INTRODUCTION: Buffers are solutions whose pH values stay fairly constant even when a small amount of strong acid or base is added to it. In order to maintain its pH, the buffer solution needs to remove the added H+ or OH– via a chemical reaction so that the concentration of these ions in solution remains nearly constant. Therefore, the buffer system needs a weak acid, HA, (to react with any added base) and its conjugate base, A–, (to react with any added acid) as shown in equations 1 and 2 below. Figure 2 shows the change in the relative amounts of HA and A–, when small amounts of H+ or OH– are added. Notice that the amounts of HA and A– vary slightly but not by much from the initial amounts. H+added OH-added When acid is added: H+added + A–buffer → HA AHA HA When base is added: OH–added + HAbuffer → H2O + A– (2) HA A- A- A- (1) HA A- Figure 1: Buffer Solution OH– added H+ added HA A– HA A– HA A– Figure 2: Buffering Action Chemistry 51 2023-2024 Page 101 PREPARATION AND PROPERTIES OF BUFFERS Calculating the concentrations of weak acids and bases in solution and the resulting solution’s pH requires the equilibrium constant expression. Although either expression can be used, it is customary to use the expression for the weak acid. [H + ] [A - ] Ka = [HA] ( 3) Rearrangement of equation 3 yields the Henderson–Hasselbalch equation: ο [A - ] [HA] pH = pK a + log (4) The Henderson–Hasselbalch equation is useful for calculations involving buffers because buffers contain large concentrations of both HA and A– (unlike solutions made from just one or the other). ο The equilibrium concentrations of both HA and A– are nearly the same as their initial concentrations (because Ka values are small, we “neglect the x’s”), so knowing the composition of the buffer and the pKa of the acid is enough to calculate the pH of the buffer solution. The pH of a buffer solution depends on two things: the pKa of the weak acid and the ratio of base to conjugate acid concentrations. If a buffer at a specific pH were to be prepared, one would select a weak acid, whose pKa most closely matches the desired pH of the buffer (the most effective buffers have an [A–]/[HA] ratio of 1). If the desired pH does not exactly match the pKa of an acid, then the required ratio of the [A–]/[HA] must be calculated to determine how much of the weak acid and its conjugate base must be used. Making a Buffer Solution from Two Solutes with a Combined Molarity – Method 1 Suppose that a student desires to make a buffer solution with a pH = 4.50. By examining the available choices, he would select a pair of compounds in which the weak acid has a pKa close to 4.50. Let us assume that the closest pKa of a weak acid was 5.00. He would use the HendersonHasselbalch to calculate the ratio of [A–]/[HA] needed to prepare the buffer. Since both A– and HA are in the same solution and therefore, have the same volume, the concentration ratio is equal to the mole ratio. In this example, he would need 0.32 mole of A– for everyone 1 mole of HA (or 0.64 mole of A– for everyone 2 mole of HA, etc). Conversion from moles to grams (for solids) or volume (for solutions) will give him the quantities of chemicals needed to make the solution. [π΄− ] (5) ππ» = ππΎπ + log [π»π΄] 4.50 = 5.00 + log log [π΄− ] [π»π΄] [π΄− ] = −0.50 [π»π΄] [π΄− ] = 0.32 [π»π΄] ⇒ (6) (7) πππ π΄− = 0.32 πππ π»π΄ Chemistry 51 2023-2024 (8) Page 102 PREPARATION AND PROPERTIES OF BUFFERS If he desires to make a buffer solution not only at a specific pH but also a specific volume and combined (or total) molarity, then he would continue with the calculations to determine the specific number of moles of each component. Let’s assume that the desired buffer volume is 1.00L and the desired combined molarity (includes both components) is 1.00 M. mol A mol HA ο mol A - = 0.32 mol HA = 0.32 (9) Total moles = M x V = 1.00 M x 1.00 L = 1.00 mole (10) Total moles = moles of A- + mole HA =1.00 mole (0.32 x mol HA)+ mole HA = 1.00 mol (11) mole HA = 0.76 mol mole A = 0.32 x mol HA = 0.24 mol Making a Buffer Solution from One Solute Reacting with a Second Solute – Method 2 ο Instead of mixing two components required to make a buffer, another way of making the buffer is to select one of the components and then create the other component in the container (in situ) through a chemical reaction. This can be accomplished by adding a strong acid (if the base component is selected) or a strong base (if the acid component is selected) since reactions of the strong acid/base with the component will essentially go to completion. Let’s continue with the combined molarity values from the example above. Suppose the student realized that although he required 0.76 mole of HA and 0.24 mole of A– to make the buffer, only HA was available. How can he still make the buffer from only one component? He can create the second component by reacting HA (weak acid) with a strong base according to the equation below. Since he wants to end up with the 0.76 mol HA and 0.24 mol A–, he can back-calculate and determine the initial moles of HA (1.00 mol) and OH– (0.24 mol) needed to accomplish the task. Notice that all OH– are consumed (reaction going to completion) so none of it is left in the buffer solution. HA Initial Mole Change in Mole Final Mole 1.00 -0.24 0.76 + OH– → 0.24 -0.24 0 H2O ---- + A– (12) 0 + 0.24 0.24 A similar kind of equation and calculation are used when a strong acid or base is added to a buffer resulting in the conversion of one buffer component into another. For example, adding a strong acid will convert some of the A– in the buffer to HA. Conversely, adding a strong base will convert some of the HA to A– (see equations 1 and 2). The only difference is that in a buffer solution there will be both HA and A– initially present in solution (unlike in the above example where there is no initial A– present). Chemistry 51 2023-2024 Page 103 PREPARATION AND PROPERTIES OF BUFFERS OH– added H+ added HA A– HA A– HA A– Initial moles of each component Since the moles of HA and A are both changed, this changes the ratio of [A–]/[HA] in the Henderson–Hasselbalch equation and therefore the pH of the solution (although not by much). Reactions with strong acids and bases go essentially to completion, so use stoichiometry first to determine the change in moles for both HA and A– (see equation 12) before using the Henderson– Hasselbalch equation. Either the mole ratio or the concentration ratio can be used in the Henderson–Hasselbalch equation. If using concentration ratio, be sure to account for volume change when adding solutions. In Part 1 of the lab, you will design and quantitatively prepare a buffer solution at a specific pH, molarity, and volume. You will choose a weak acid and its conjugate base from a list to make the buffer and using Method 1 as explained above, determine the amount of the weak acid and the conjugate base needed. The pH of the prepared buffer will be measured and compared to the theoretical value. In Part 2 of the lab, you will add a quantity of strong acid and strong base to buffered and non– buffered systems and determine their effect by measuring and comparing their pH values before and after the addition. In Part 3 of the lab (check with your professor to see whether you will do this part), you will design and prepare a buffer solution using only one of the components from the chosen pair from Part 1 and create its conjugate component in solution by adding either a strong acid or strong base. You will then be asked to determine the volume of acid or base needed to increase or decrease the pH of the buffer by a specific amount. PRE–LAB QUESTIONS: 1. What are buffers? What are the two components of a buffer? 2. Derive the Henderson–Hasselbalch equation from the Ka expression. 3. Which of the following pairs of chemicals will produce a buffer? a. HCl and HC2H3O2 c. H2CO3/Na2CO3 b. NaF and HF d. NH3 and NaOH 4. Write balanced net ionic equations that show how a buffer containing NaHCO3 and Na2CO3 maintains its pH when a small amount of HCl or NaOH is added. Chemistry 51 2023-2024 Page 104 PREPARATION AND PROPERTIES OF BUFFERS 5. Calculate the pH of a buffer made from mixing 10.0 mL of 0.100M NaC2H3O2 and 10.0 mL of 0.100M HC2H3O2. a. Calculate the pH of the buffer when 5.00 mL of a 0.0100 M NaOH is added. b. Calculate the pH of the buffer when 5.00 mL of a 0.0100 M HCl is added. CHEMICALS AND MATERIALS Solutions 0.0100 M NaOH 0.0100 M HCl 0.100 M NaOH 0.100 M HCl 1.00 M NaOH 1.00 M HCl 1.00 M HC2H3O2 1.00 M NH3 0.1 M NaCl Solids NaC2H3O2 • 3H2O NaHCO3 Na2CO3 NaH2PO4 Na2HPO4 Na3PO4 • 12H2O NH4Cl pH 4, 7, and 10 buffers EQUIPMENT TO BE CHECKED OUT 50mL volumetric flask + lid/stopper 5mL graduated pipet 4 50mL beakers Vernier Go Direct pH sensor Laptop computer SAFETY Goggles must be worn in the laboratory. WASTE DISPOSAL Dispose used solutions in the chemical waste container. EXPERIMENTAL PROCEDURE: Part 1: Preparation of a Buffer From a Weak Acid/Base and Its Conjugate 1. Obtain your buffer assignment (pH and total molarity) from your professor. 2. Select an appropriate pair from the list below to prepare 50.00 mL of your assigned buffer. Consult your text for Ka or Kb values. a. b. c. d. e. NaC2H3O2•3H2O(s) and HC2H3O2(aq, 1.00 M) NaHCO3(s) and Na2CO3(s) Na2HPO4(s) and Na3PO4•12 H2O(s) NaH2PO4(s) and Na2HPO4(s) NH4Cl(s) and NH3 (aq, 1.00 M) Chemistry 51 2023-2024 Page 105 PREPARATION AND PROPERTIES OF BUFFERS 3. Calculate the mass or volume of acid and base components needed to obtain the pH and molarity assigned (see example calculation for Method 1 in the Introduction). Note: Some salts contain waters of hydration in the formula so be sure to include them in the calculation for molar mass.) Check your answers with your professor. 4. Write a detailed procedure on how you would prepare 50.00 mL of the desired buffer using the chemicals above. Obtain instructor’s approval. 5. Check out the 50 mL volumetric flask and lid, Go Direct pH sensor, and laptop computer from your professor. Prepare the buffer in the volumetric flask according to your procedure. 6. Follow the directions provided to connect the Go Direct pH sensor to your laptop or mobile device. Calibrate the pH sensor with a three-point calibration. 7. Pour the prepared buffer into a clean, dry 150 mL beaker and measure and record the pH of the buffer. The measured pH value of your buffer should be identical (or very close) to the assigned value. Save the prepared buffer for Part 2. 8. Rinse the volumetric flask with tap water and do a final rinse with DI water. Return the clean flask to the professor. Part 2: Properties of Buffered and Non–buffered Systems 9. Check out a 5-mL graduated pipet and pipet pump from your professor. 10. Obtain and label (#1-4) 4 clean and dry 50mL beakers. 11. Add the following liquids/solutions into the beakers using a 50-mL graduated cylinder. a. Beaker 1—20.0 mL of 0.1 M NaCl. b. Beaker 2—20.0 mL of 0.1 M NaCl. c. Beaker 3—20.0 mL of your prepared buffer from Part 1. d. Beaker 4—20.0 mL of your prepared buffer from Part 1. 12. Measure and record the pH of the contents in each beaker. Be sure to rinse the electrode with deionized water in between uses to avoid contamination. DO NOT blot the electrode with paper towels or Kimwipes. 13. Effect of acid: Add 5.00 mL of 0.0100 M HCl solution (be sure to condition the pipet first) into beakers 1 and 3. Mix the contents well and measure and record the pH. 14. Effect of base: Add 5.00 mL of 0.0100 M NaOH solution (be sure to condition the pipet first) into beakers 2 and 4. Mix the contents well and measure and record the pH. 15. Dispose of all solutions into the chemical waste container. Chemistry 51 2023-2024 Page 106 PREPARATION AND PROPERTIES OF BUFFERS Part 3: Preparation of a Buffer Using One Component 16. Write a detailed procedure (using Method 2) for the preparation of 50.00 mL of the same assigned buffer (same pH and molarity) using just ONE of the chemicals from the pair you selected in step 2 and either 1.00 M NaOH OR 1.00 M HCl to generate the conjugate species in situ. Once your calculations and procedure are approved by your professor, check out the 50-mL volumetric flask and prepare the buffer accordingly. 17. Pour the buffer into a 100 mL beaker. Measure and record the pH of the solution. Optional Extension 18. Obtain two clean and dry 50-mL beakers (beakers 1 and 2). Using a 50-mL graduated cylinder, pour 20.0 mL of the buffer into each of the beakers. 19. Calculate the volume of 0.100 M HCl required to decrease the pH of the buffer solution by 0.15 pH units in beaker 1. 20. Calculate the volume of 0.100 M NaOH required to increase the pH of the buffer solution by 0.10 pH units in beaker 2. 21. Once your calculations and procedure are approved by your professor, use a conditioned pipet and add the calculated volume of acid (or base) into the beakers. Measure and record the new pH. 22. Dispose of the solutions into the waste containers. Return all checked out items (including the laptop and pH sensor) to your professor. DATA ANALYSIS: Part 1: Preparation of a Buffer From a Weak Acid/Base and Its Conjugate 1. Complete the table below. If the actual amounts of the weak acid/base and its conjugate used during the preparation differ from the calculated amounts, compute the new target pH. Target pH Measured pH % error Buffer 2. What are some likely sources of error for the preparation of the buffer? Chemistry 51 2023-2024 Page 107 PREPARATION AND PROPERTIES OF BUFFERS Part 2: Properties of Buffered and Non–buffered Systems 1. Using your measured pH values, calculate the concentration of H+ (M) in beakers 1 and 3, before and after the addition of HCl. Organize your answers in a table as shown below. Initial measured pH Initial [H+] (M) Final measured pH [H+] (M) after addition of HCl By what factor did the [H+] (M) increase? Beaker 1 (0.1M NaCl) Beaker 3 (Buffer) 2. Using your measured pH values, calculate the concentration of H+ (M) in beakers 2 and 4, before and after the addition of NaOH. Organize your answers in a table as shown below. Initial measured pH Initial [H+] (M) Final measured pH [H+] (M) after addition of NaOH By what factor did the [H+] (M) decrease? Beaker 2 (0.1M NaCl) Beaker 4 (Buffer) 3. Which system (buffered or non-buffered) shows a smaller increase/decrease in the concentration of H+? Explain. 4. For each beaker, calculate the expected (theoretical) pH when 5.00 mL of 0.0100 M HCl or 5.00 mL of 0.0100 M NaOH is added to 20.0 mL of buffered and non-buffered systems. Use the actual volume of acid/base added in the calculation. Organize your answer in a table as shown below. Actual volume of acid or base added (mL) Measured pH Calculated (Theoretical) pH % error 0.1M NaCl + acid (beaker 1) 0.1M NaCl + base (beaker 2) Buffer + acid (beaker 3) Buffer + base (beaker 4) Chemistry 51 2023-2024 Page 108 PREPARATION AND PROPERTIES OF BUFFERS Part 3: Preparation of a Buffer Using One Component (Optional) 1. Complete the table below. Target pH Measured pH % error Buffer Buffer + acid (beaker 1) Buffer + base (beaker 2) 2. What are some likely sources of error for the preparation of the buffer and the addition of acid/base? POST–LAB QUESTIONS: 1. What is the effect on the pH of the solutions in beaker 1 and 3 if the pipet was rinsed with DI H2O but not conditioned with the HCl solution? 2. Which of the following pairs of solutions will produce a buffer solution? Explain your reasoning. a. 10.0 mL of 0.10 M HCl + 10.0 mL of 0.10 M NaOH b. 10.0 mL of 0.10 M HCl + 5.0 mL of 0.10 M NaOH c. 10.0 mL of 0.10 M HF + 10.0 mL of 0.10 M NaOH d. 10.0 mL of 0.10 M HF + 5.0 mL of 0.10 M NaOH 3. Student Q prepared 50.0 mL of a buffer solution using 0.50 moles of HA and 0.50 moles of A– while Student S prepared 50.0 mL of a buffer solution using 0.25 moles of HA and 0.25 moles of A–. a. Do the two buffer solutions have the same or different pH? Explain. b. If 1.00 mL of 0.010M NaOH were added to the two buffer solutions, would the pH of the two solutions increase or decrease? Explain. c. Which solution (Buffer Q or Buffer S) would show a smaller change in the pH for question (b)? Explain. Chemistry 51 2023-2024 Page 109 PREPARATION AND PROPERTIES OF BUFFERS REFERENCES: Written by Jenny Leung and Janet Truttmann, April 2011. Updated July 2022. Chemistry 51 2023-2024 Page 110 TITRATION OBJECTIVES: • Standardize a solution of sodium hydroxide • Generate and compare the pH curves of a strong acid/strong base titration and a weak acid/strong base titration • Determine the identity of an unknown monoprotic weak acid based on its molar mass and pKa value INTRODUCTION: Titration is a common laboratory technique (one type of volumetric analysis) used in the chemistry laboratory to determine the concentration of an unknown (the analyte) by quantitatively adding a known volume of a reagent known as the titrant. Two common titrations often performed in chemistry labs are acid-base and oxidation-reduction titrations. In this experiment, several acidbase titrations will be performed using the set up shown below. Titrant Analyte O n Off St i r rer Figure 1 Titration Set Up A buret is used to quantitatively deliver a variable volume of the titrant (NaOH) into a beaker containing the analyte (acid) until they have fully reacted according to stoichiometric ratio. This point in the titration (when all the acids have been neutralized by the added base) is known as the equivalence point. Since information about the acid is dependent on the volume and concentration of the NaOH used, it is critical to have the exact molarity of the titrant. In Part 1 of this experiment, a solution of sodium hydroxide will be standardized using potassium hydrogen phthalate (KHC8H4O4). KHC8H4O4 is an acidic salt that dissociates completely into potassium (K+) and hydrogen phthalate (HC8H4O4–) ions in water. The hydrogen phthalate ion acts as a weak monoprotic acid and reacts with sodium hydroxide according to the following net ionic equation: HC8H4O4– + OH– → H2O + Chemistry 51 2023-2024 C8H4O42– (1) Page 111 TITRATION Sodium hydroxide solutions are prepared from NaOH pellets which contain trace impurities of KOH. In addition, the concentration of NaOH decreases over time due to the neutralization reaction with carbon dioxide in the air. Therefore, it is important to determine the exact molarity of NaOH through a standardization procedure immediately before the solution is used in titrations. The calculation involved in this process is shown below: Volume of NaOH at equivalence point Grams of KHP Moles of KHP Moles of NaOH Molarity of NaOH Since all the reactants and products in the reaction are clear and colorless solutions, it is impossible to know when the reaction is complete (i.e. have reached the equivalence point). One method to aid visualization of the equivalence point is through the use of an acid-base indicator such as phenolphthalein. Acid-base indicators are dyes derived from plants that display different colors at different pH values. For instance, phenolphthalein is colorless in solutions with pH < 8.3 but turns a reddish-pink color in solutions with pH > 9.5. The pH range in which an indicator changes color is known as its end point. Since different indicators have different end points (as shown in Table 1), the selection of a specific indicator for use in titrations to visualize the equivalence point must be done carefully. In other words, if the pH at the equivalence point is 8.5, phenolphthalein would be a good choice but bromophenol blue would be a poor choice. Table 1: Some Common Acid-Base Indicators Indicators Colors pH range (end point) Crystal violet Yellow-Blue 0.3-1.7 Thymol Blue Red-Yellow 1.5-2.5 Bromophenol blue Yellow-Blue 3.2-4.0 Methyl red Red-Yellow 4.6-6.0 Bromothymol Blue Yellow-Blue 6.2-7.0 Phenolphthalein Colorless-Pink 8.3-9.5 Thymolphthalein Colorless-Blue 9.5-10.2 A second way to visualize the equivalence point is the construction of a pH curve. In Part 2 of the experiment, a pH meter will be used to monitor the progress of two titrations: HCl (strong acid)/NaOH and HC2H3O2 (weak acid)/NaOH. Initially the pH of an acidic solution is low since there are plenty of hydronium ions (H3O+) in solution. However, as a base is added, neutralization of the acid occurs, lowering the amount of H3O+ in solution and raising the pH of the solution. Initially, the rise in pH is gradual as there is a large quantity of H3O+ in solution. However, near the equivalence point, the pH rises sharply even with a small addition of a base. The pH then levels off as excess hydroxide ions (OH-) are added (See Figures 2 and 3). Chemistry 51 2023-2024 Page 112 TITRATION pH curves of strong acid-strong base (SA/SB) and weak acid-strong base (WA/SB) titrations are shown below. Notice that the equivalence point is the inflection point (the point where the slope changes) in the titration curve. This point can be found by visual inspection of the graph. Figure 3 Weak Acid-Strong Base Titration An alternative approach to finding the inflection point is to take the first derivative of the pH curve. The inflection point is the maximum as shown in the second graph. This point can be easily determined using the statistical function in Graphical Analysis. Equivalence point Figure 4 Another important point in the titration graph of a weak acid-strong base is the half-way point or half-equivalence point. This is the point in the titration when the volume of base added is half the amount needed to reach the equivalence point. Half of the initial moles of acid has reacted with the added NaOH to produce the conjugate base. At this point, the concentration of the weak acid and its conjugate base are the same (the ratio is 1) and the resulting solution is at its greatest buffer capacity. [conjugate base ] = [weak acid] Chemistry 51 2023-2024 Page 113 TITRATION Thus, according to the Henderson-Hasselbalch equation (equation 2), the log term drops out and the pH of the solution is equal to the pKa of the acid. ππ» = ππΎπ + log [πππππ’πππ‘π πππ π] = [π€πππ ππππ] ππΎπ + log(1) = ππΎπ (2) pH = pKa at the half-equivalence point Since pKa is a physical property of a weak acid, it can be used to determine its identity. In Part 3 of the experiment, a measured mass of an unknown, monoprotic weak acid will be titrated against a standardized solution of sodium hydroxide. By constructing a pH curve from the titration data, the pKa (see discussion above) and the molar mass of the acid (equation 3) can be obtained. The moles of the acid can be calculated from the volume and molarity of the sodium hydroxide at the equivalence point since the mole of the acid is equal to the mole of the added base (1:1 stoichiometric ratio). πππππ πππ π ππ π‘βπ ππππ = πππ π ππ π‘βπ ππππ πππππ ππ π‘βπ ππππ (3) In summary, we will be performing a total of four different titrations in this experiment. In Part 1 of the experiment, a solution of sodium hydroxide will be standardized using KHP and the titration will be monitored using an acid-base indicator. In Part 2, equimolar and equal volumes of hydrochloric acid and acetic acid solutions will be titrated with a standardized sodium hydroxide solution, and the titration will be monitored with a pH meter. In Part 3, an unknown weak acid will be titrated with standardized sodium hydroxide in order to determine its identity by comparing the experimental molar mass and pKa to a list of known acids. PRE-LAB QUESTIONS: 1. What is the difference between end point and equivalence point? How is the equivalence point determined in Part 1? Part 2? Part 3? 2. Compare the two titration curves (Figure 2 and 3 in the Introduction) to answer the following questions. a. Write the balanced chemical equations for the reaction between HCl/NaOH and HC2H3O2/NaOH. b. Which figure shows a lower initial pH on the pH curve? Why? c. Why is the pH at the equivalence point different on the two graphs? Explain. d. What volume of NaOH is needed to reach the equivalence in both graphs? Explain why they are the same. Assume that both the volume and molarity of the strong acid and the weak acid, and the molarity of NaOH used in the titration are the same. Chemistry 51 2023-2024 Page 114 TITRATION 3. For the reaction between KHC8H4O4 and NaOH in Part 1, a. Approximately how many grams of KHC8H4O4 will neutralize 10 mL of 0.20 M NaOH solution? b. Calculate the pH at the equivalence point for the reaction between KHC8H4O4 and NaOH from part (a). Assume that the total volume of the solution at equivalence point is 40 mL. Look up the pKa of KHC8H4O4 from a reference table. c. Based on your answer from above, which acid-base indicator (see Table 1 in the Introduction) should be used for the titration? Explain your reasoning. 4. How will you dispose of all excess and neutralized solution? CHEMICALS AND MATERIALS Solid KHC8H4O4 0.20 M NaOH 0.100 M HCl 0.100 M HC2H3O2 Unknown acid pH 4, 7, and 10 buffers Indicators (in solution): crystal violet bromothymol blue thymol blue phenolphthalein bromphenol blue thymolphthalein methyl red EQUIPMENT TO BE CHECKED OUT 25 mL buret + buret reading card Magnetic stir bar + Magnetic stirrers Pipet pump Vernier Go Direct pH sensor Laptop computer SAFETY Goggles must be worn in the laboratory. WASTE DISPOSAL Dispose all excess and used solutions in the chemical waste container. EXPERIMENTAL PROCEDURE: • Obtain approximately 150 mL of 0.20M NaOH solution in a clean and dry 250 mL Nalgene plastic bottle. The bottle should be kept closed when not in use to minimize exposure to CO2. This NaOH solution will be kept in your drawer and used for all 3 parts, so be sure to use it sparingly. • Check out the following items from your professor: a buret, a buret reading card, and a magnetic stir bar. (buret clamps, ring stands, and magnetic stir plate can be found in the lab room). Chemistry 51 2023-2024 Page 115 TITRATION Cleaning, Condition, and Setting up the buret • Clean and set up the buret as follows: β Check the buret to be sure that it is not leaking and the stopcock turns easily. Rinse the buret with tap water and then do a final rise with DI H2O. If water does not drain properly or beading occurs inside the buret, clean the buret with soapy water and a buret brush. β Condition the buret with approximately 5 mL of 0.20M NaOH solution. Be sure to drain the NaOH through the buret tip. The used NaOH solution should be placed in a beaker labeled “Waste NaOH solution.” Repeat the conditioning two more times. Place the “Waste NaOH solution” beaker underneath the buret to catch any drips when the buret is not in use. β Clamp the conditioned buret to the ring stand and fill the buret with a fresh 0.20M NaOH solution (use a clean, dry funnel as needed) so that the liquid level is above the 0.00mL mark. Drain some NaOH solution through the tip of the buret so it is filled with the fresh NaOH solution and the level of the NaOH in the buret is slightly below the 0.00 mL mark. Check to be sure that there are no air bubbles in the tip. β Have your instructor check your set up. Record the initial volume of the NaOH solution (use the buret reading card to aid in the reading) in your notebook. Part 1: Standardization of NaOH Solution (Optional) 1. Check with your professor to see whether you will be performing this part of the experiment. If you are doing this part, check and see whether you are performing multiple trials or doing a single trial and pooling your data with those of your classmates working at your lab bench. 2. Weigh out the calculated mass of KHC8H4O4 (see answer to Pre-Lab Question #3) on a weighing boat or paper and quantitatively transfer all the solids into a clean 125 mL Erlenmeyer flask. Record the exact mass of the KHC8H4O4 used. 3. Measure 30.0 mL of DI H2O in a graduated cylinder and add to the KHC8H4O4 in the flask. Add three drops of the chosen indicator (see answer to Pre-Lab Question #3c). Add the magnetic stir bar to the flask and stir the solution on a magnetic stir plate to dissolve the KHC8H4O4. 4. Titrate the dissolved KHC8H4O4 until the end point is reached using the procedure below. a. Place the Erlenmeyer flask underneath the buret so that the tip of the buret is slightly inside the flask. b. Open the stopcock of the buret and drain the NaOH solution into the flask. Based on your calculations, it should take approximately 10 mL of the NaOH to reach the equivalence point, so add approximately 8 mL of NaOH solution quickly. c. Add NaOH solution drop wise as you near the end point—you can see this visually as the color change in the solution stays longer and longer in the flask. As you near Chemistry 51 2023-2024 Page 116 TITRATION the end point, consider adding “partial drops”—open the stopcock and let a “partial drop” hang on the tip of the buret. Squirt DI H2O from a wash bottle so that the drop falls into the flask d. . Be sure to stop the addition of NaOH and swirl completely before adding the next “partial drop.” The end point is reached when a faint color persists for more than 30 seconds. Record the color of the solution in the flask and the final volume of the NaOH. 5. Based on the exact mass of KHC8H4O4 and the volume of NaOH used in the titration, calculate the exact concentration of NaOH (be careful with significant figures). Repeat the titration for additional trials or report the concentration to your professor for pooled data. (Note: An average value of the concentration of NaOH will be computed using student data for each lab bench and written on the board. Copy this average concentration down in your notebook. This concentration will be used for Data Analysis for Part 2 and 3, as well as for Post-Lab Question #1). 6. Remove the magnetic stir bar from the flask using tweezers or by holding the magnetic stir bar retriever (blue device available at the fume hood) against the side of the beaker as you pour the beaker contents to waste. Dispose the neutralized KHC8H4O4 solution into the waste container provided in the fume hood. Rinse the flask and magnetic stir bar with tap water and do a final rinse with DI H2O. 7. Refill the buret with more NaOH (if continuing with Part 2) so that the initial volume in the buret is a little bit below the 0.00 mL mark. Part 2: Titrations of HCl/NaOH and HC2H3O2/NaOH 8. Obtain approximately 35 mL of 0.100 M HCl in a clean Erlenmeyer flask. Condition a 10mL volumetric pipet with the HCl solution. Pipet 20.00 mL of 0.100 M HCl solution into a clean, dry 100 mL beaker. 9. Check out the Go Direct pH sensor and laptop computer from your professor. Follow the directions provided to connect the Go Direct pH sensor to your laptop or mobile device. Perform a Three-point calibration using pH 4, 7, and 10 buffers. 10. Set up the titration apparatus as shown in Figure 5. • Condition a buret and clamp it to a ring stand with a buret clamp. Fill the buret with the standardized NaOH solution. • Place the 100-mL beaker containing the acid solution on top of a stir plate. • Attach a utility clamp to the ring stand. Gently place the pH sensor on the clamp. Adjust the height of the clamp so that the bulb of the electrode is completely submerged in the solution. • Add a magnetic stir bar into the beaker and begin gentle stirring. Be sure that the magnetic stir bar does not hit the electrode. Chemistry 51 2023-2024 Figure 5 Page 117 TITRATION 11. After the pH sensor has been calibrated, click on the square icon on the top right corner and select Graph and Table. 12. Next, change the mode of data collection. On the bottom left hand corner, change the Mode to Event Based to collect data manually. 13. Select “Events with Entry” for Event Mode. Type in “Buret Reading” for Event Name and “mL” for Units. Click DONE. The heading in the data table and the labels on the axes of the graph will change to show pH and Buret Reading. 14. Once the table is set up, and you are ready to start the titration, click “COLLECT”. 15. The pH of the solution will be displayed at the bottom right hand corner. 16. Once it is stabilized, click “KEEP”. 17. A dialog box will appear allowing you to record the buret volume in the box provided. Click “KEEP POINT”. The volume and pH value will show up in the data table and a point will be plotted. Chemistry 51 2023-2024 Page 118 TITRATION 18. Add one drop of NaOH solution into the beaker. After the pH stabilizes, click “KEEP” and observe and enter the buret volume into the table and in your notebook. 19. To continue the titration, add NaOH solution slowly into the beaker until the pH rises by about 0.20 units. Record the buret readings and pH values in the table and your notebook as before. Continue in this way (recording titration points every ~0.20 pH units) until the pH reaches an upper plateau region and changes very little (~ pH 12.0). Note: As seen from the graph, the pH will start to rise dramatically with a small addition of NaOH when you get close to the equivalence point. It is strongly recommended that the NaOH solution be added drop wise or partial drop wise slowly near the equivalence point. 20. Once the data collection for the titration is completed, click “STOP”. Save the data on the desktop by clicking on the rectangular icon in the upper left corner. You can save the file type as Vernier Graphical Analysis or export the data as a .csv file. Check with your professor. 21. Ask your professor whether you should also record the data in your lab notebook as shown below. Add more spaces as needed. pH Buret reading (mL) 2.34 0.10 Continue recording pH Continue recording volume of NaOH 22. Rinse the bottom section of the pH sensor, especially near the bulb, with deionized water. Place the pH sensor back into the storage solution while you clean up and set up for the WA/SB titration. 23. Remove the stir bar from the beaker. Dispose the neutralized solution into the waste container. Wash, rinse, and dry the beaker. 24. Refill the buret with fresh NaOH solution. Do a second titration (20.00 mL of 0.100 M HC2H3O2 with NaOH) using the same procedure as above. 25. Dispose of any remaining excess HCl, HC2H3O2, and NaOH solutions into the waste container. Return the laptop and the pH sensor to your professor if you are stopping for the day. Part 3: Titration of an Unknown Acid 26. Obtain an unknown acid from your professor. Record the weak acid unknown number in your lab notebook, along with initial observations of the acid. Measure approximately 0.20.3 grams (record the exact mass) of the unknown acid in a clean and dry150 mL beaker. Chemistry 51 2023-2024 Page 119 TITRATION 27. Using a graduated cylinder, measure 30.0 mL of DI H2O and add to the acid. Place the magnetic stir bar into the beaker and stir gently on the stir plate to dissolve all the acid. If the acid does not dissolve within 5-10 minutes, you may need to heat the solution to help the dissolution process. 28. Titrate the unknown acid using the procedure from Part 2 until the pH reaches an upper plateau and changes very little (~ pH 12.00). Remove the magnetic stir bar from the flask. Dispose the neutralized unknown acid solution into the waste container provided in the fume hood. Rinse the beaker and magnetic stir bar with tap water and do a final rinse with DI H2O. Perform a second trial of the titration of the unknown if time allows (or as directed by your professor). 29. Dispose of the solid unknown by emptying out the unknown solid into the waste container in the fume hood. The empty plastic baggie can be thrown into the trashcan. 30. Empty the contents of the buret into the “Waste NaOH solution” beaker and dispose the solution into the waste container. Wash all the glassware with tap water and then do a final rinse with deionized water. Return the checked out items back to your professor. DATA ANALYSIS Part 1. Standardization of NaOH (Optional) 1. If you are using pooled class data, how does your calculated molarity of NaOH compare with the average? Compute the percent error using the average as the “Theoretical” value. Is the percent error within the expected range based on the limitation of the glassware used? Explain. 2. If you performed multiple trials for the titration, compute the average and the standard deviation. Is the standard deviation within the expected range based on the limitation of the glassware/instrumentation used? Explain. Part 2. Titrations of HCl/NaOH and HC2H3O2/NaOH 3. Ask your professor whether you will be using Graphical Analysis or Excel to analyze and graph your data. The directions below are for Graphical Analysis. 4. Launch Graphical Analysis on the computer. Click or tap “Sensor Data Collection”. If there are no sensors, it will not detect any. Click “DONE.” 5. Click on the icon on the upper left corner and open your file. The data table and graph of the file will be displayed. Chemistry 51 2023-2024 Page 120 TITRATION 6. Create a calculated column (Volume of NaOH) by clicking on the three dots by the column heading in the data table. Select “Add Calculated Column”. Type in the information requested as shown below for Name (Volume of NaOH), Units (mL) and Displayed Precision (2). Click on “INSERT EXPRESSION” and select “X-A”. Column X should be “Buret Reading” and Parameter A should be the first buret reading (initial volume of NaOH). Type that number in and click “APPLY.” 7. A new column will appear in the data table and a new graph (pH vs Volume of NaOH) will be displayed. Click on the graph view icon on the lower left and select “EDIT GRAPH OPTIONS”. Type in the title of the graph, and select “Both” for Appearance. Click on the “X” to exit. A graph with selected options will be displayed. Chemistry 51 2023-2024 Page 121 TITRATION 8. To find the equivalence point using the first derivative of the pH curve, click on the three dots next to the pH column heading in the data table, similar to what was done before. Type in “First Derivative” for name, select the expression “1st Derivative (Y,X)”, and use the drop down menu to ensure that Column Y is “pH” and Column X is “Volume of NaOH”. Click “APPLY.” A new calculated column “First Derivative” will be added to the data table. 9. To plot the graph of first derivative and overlay it on the existing pH curve, click on the Y axis label (pH). Select “First Derivative” and a check mark will appear. There should be two graphs displayed – pH curve and First Derivative. Double clicking anywhere on the graph will autoscale. 10. To find the peak of the first derivative curve, which is the equivalence point, click on the graph view icon on the lower left corner and select “View Statistics”. Scroll down to the statistics for the first derivative and look at the volume where Max occurs. In the example below, the volume of NaOH at the equivalence point is 19.10 mL. Chemistry 51 2023-2024 Page 122 TITRATION 11. To mark several important points (Points A, B, C, D) along the titration graph using the tools in Graphical Analysis, follow the steps below. Alternatively, you can print out your graphs and mark those points manually on the graphs. 12. Turn on the INTERPOLATION tool in the GRAPH TOOLS to estimate x,y values between data points. Click on the screen to bring up the interpolation line. Drag this line to the appropriate volumes for each of the following special points to read the associated pH values. Point A: before any NaOH has been added Point B: at the half equivalence point Point C: at the equivalence point Point D: at 1.00 mL after the equivalence point pH reading Volume reading 13. Use the ADD ANNOTATION tool in the GRAPH TOOLS to label points A-D on the graph (see example). 14. Use the PRESENTATION tool to increase the size of the font of the labels to be better visible in your report. Choose either scale factor 1.25 or 1.5. Chemistry 51 2023-2024 Page 123 TITRATION 15. The graph can be exported as an image and the data as a .csv file (you will need to edit the table headings in Word or Excel) to be include in your lab report. Check with your instructor. 16. Create a table similar to the one shown below using data from both titration graphs. HCl vs NaOH Volume of NaOH added (mL) Experimental pH HC2H3O2 vs NaOH Volume of NaOH added (mL) Experimental pH Point A Point B Point C Point D 17. How do the pH values at point A compare in the two graphs? Explain. 18. Since the same volume and molarity of HCl and HC2H3O2 were used, the volume of NaOH required to reach the equivalence point should be the same. Compare the experimental volumes of NaOH at Point C in both graphs. Explain any discrepancies. Chemistry 51 2023-2024 Page 124 TITRATION 19. How do the pH values at point C compare in the two graphs? Explain. 20. Which point on the graph corresponds to the pKa of the acid (only for the weak acid)? Explain. 21. Compare the experimental pKa of HC2H3O2 with the theoretical value. Calculate the percent error. Part 3: Identification of an Unknown Weak Acid. 22. Use Graphical Analysis to generate a table and pH curve for the unknown acid titration as in Part 2. Label the equivalence point and the half-way to the equivalence point on the graph. 23. Calculate the molar mass of the unknown acid using titration data. Reminder: be sure to use the average concentration for NaOH from Part 1. 24. Determine the pKa of the unknown acid from the titration graph. 25. Determine the identity of the unknown acid based on its molar mass and pKa. (See table below). Calculate the percent error for the molar mass and the pKa. Possible Acids benzoic acid potassium hydrogen tartrate potassium hydrogen phthalate citric acid lactic acid sodium hydrogen phosphate sodium dihydrogen phosphate sodium hydrogen carbonate ammonium chloride ascorbic acid Formula C6H5COOH KHC4H4O6 KHC8H4O4 H3C6H5O7 HC3H5O3 Na2HPO4 NaH2PO4 NaHCO3 NH4Cl C6H8O6 MM (g/mol) 122.13 188.18 204.23 192.14 90.09 141.96 119.98 84.01 53.50 176.12 pKa 4.19 4.34 5.41 3.16 3.85 12.38 7.21 10.25 9.25 4.17 POST-LAB QUESTIONS: 1. In Part 2 of the experiment, 20.00 mL of 0.100M HCl was titrated with a standardized solution of NaOH. a. Using the exact molarity of NaOH found through the standardization (the value obtained from Data Analysis for Part 1), calculate the volume of NaOH needed to reach the equivalence point. b. Calculate the theoretical pH values at points A, B, C, and D using the molarity and volume of NaOH from part “a”. c. Organize your results in a table such as the one shown below. Compare the theoretical and experimental pH values and calculate % error. Chemistry 51 2023-2024 Page 125 TITRATION Theoretical pH Experimental pH % Error Point A Point B Point C Point D 2. Repeat question #1 for the titration between 20.00 mL of 0.100M HC2H3O2 and NaOH. 3. How would the pH graph of a polyprotic acid such as H2SO4 differ from a monoprotic acid such as HCl? Include a rough sketch in your explanation. 4. How would the pH graph differ if the NaOH was the analyte and HCl was the titrant? Include a rough sketch in your explanation. 5. How would the molar mass of the unknown be affected (increase, decrease, no change) if the following occurred during the lab? Explain. a. Some unknown solids were spilled while transferring into the beaker. b. The buret was rinsed with DI H2O but not conditioned with the 0.20 M NaOH solution. REFERENCES: Written by Jenny Leung, April 2011 (Reviewed and edited by Janet Truttmann and Terri Beam June 2011); Last updated July 2022 Graphs of Sample Data and Strong Acid and Base Titration Using Go Direct pH by Vernier (https://www.vernier.com/products/sensors/ph-sensors/gdx-ph/) Chemistry 51 2023-2024 Page 126 OXIDATION-REDUCTION REACTIONS OBJECTIVES: • Perform a series of experiments exploring the effect of pH (acidic and basic conditions) on oxidation-reduction (redox) reactions. • Balance redox reactions by the half-reaction method under acidic and basic conditions. • Determine an activity series based on reducing strength of select elements • Determine the percent of hydrogen peroxide in a commercial solution of hydrogen peroxide using a redox titration. INTRODUCTION: Oxidation and reduction (redox) reactions are an important part of chemistry. Some examples include rusting of iron and electroplating precious metals on the surface of cheaper metals. Redox reactions involve a transfer of electrons. In other words, a reactant gives up electrons and transfers them to another reactant that accepts them. In first semester General Chemistry, balancing redox reactions was covered. In second semester General Chemistry, we explore the effect of pH (acidic or basic conditions) on redox reactions. It is much more complex to balance a redox reaction under acidic or basic conditions. There are several ways to do this and different resources have different approaches but with the same outcome – a balanced redox reaction. Please see your textbook or instructor notes on how to balance redox reactions in acidic and basic conditions. In the first part of this experiment, we explore the relative reactivity (activity series) of different metals. An activity series places metals and hydrogen gas in order of strength as reducing agents (the species that undergoes oxidation) in aqueous solution. A partial activity series of metals and hydrogen is shown in the following table: Strength as Reducing agents Metal Oxidation Reaction Strongest Li Li → Li+ + eNa Na → Na+ + eFe Fe → Fe2+ + 2eH2 H2 → 2H+ + 2eWeakest Au Au → Au3+ + 3eTherefore the following reaction will take place Fe(s) + 2 H+ (aq) → H2 (g) + Fe2+ (aq) because Fe is a stronger reducing agents than H2 (Fe is more likely to be oxidized than H2). Fe is able to give up electrons more easily than H2 since it lies higher on the activity series. Revised 06/26/2022 Chemistry 51 2023-2024 Page 127 OXIDATION-REDUCTION REACTIONS In the second part of this experiment, we explore the effect of acidity on different reactions. In the last part of this experiment, we will determine the percent by mass of H2O2 in a solution of H2O2 by doing a microscale titration on a mass basis. Recall that mass percent of a solute is as follows: % ππ ππππ ππππππ ππ π ππππππππ = ππππ ππππππ π πππ% ππππ ππππππππ Using the masses of the solutions used and the stoichiometry of the reaction, the experimental percentage of H2O2 can be determined and compared to the actual percent H2O2 listed on the label of commercial hydrogen peroxide solution. PRE-LAB QUESTIONS: 1. Fill in the last column in the table below with the oxidation state of the underlined species. Name of Species Chemical formula Color in aqueous solution Permanganate ion MnO4-(aq) Purple Manganate ion MnO42- (aq) Green Manganese (IV) oxide MnO2(s) Brownish-black precipitate Manganese (II) ion Mn2+ faint pink to colorless Sulfate ion SO42- Colorless Sulfite ion SO32- Colorless Zinc ion (in acidic solution) Zn2+ Colorless Tetrahydroxo zinc ion (in basic solution) [Zn(OH)4] 2- Colorless Oxygen gas O2(g) bubbles Ox. State of underlined species 2. Balance the following redox reaction in acidic solution: MnO4-(aq) + H2C2O4(aq) → Mn2+ (aq) + CO2 (g) 3. Balance the following redox reaction in basic solution: ClO-(aq) + Cr(OH)4- (aq) → CrO42- (aq) + Cl- (aq) Chemistry 51 2023-2024 Page 128 OXIDATION-REDUCTION REACTIONS 4. In one part of the experiment, a titration is performed. The KMnO4 is a colored solution and the H2O2 solution is colorless. This titration is performed without the use of an indicator. How will you recognize the equivalence point? 5. A 5.54 g sample of vinegar, which contains acetic acid, was neutralized by 30.10 mL of 0.100M NaOH. What is the percent by mass of acetic acid in vinegar? 6. Write an activity series for the generic metals, A, B, C, D if the following observations were made: D + B2+ → no reaction C + B2+ → C2+ + B B + A2+ → B2+ + A A + D2+ → no reaction ___?___ > ___?___ > ___?___ > ___?___ CHEMICALS AND MATERIALS Pieces of the following metals: Mg, Cu, and Zn 0.10 M solutions of : Cu(NO3)2, ZnSO4, Mg(NO3)2, AgNO3 6 M HCl 0.01 M KMnO4 6 M HCl 6 M NaOH 0.1 M Na2SO3 (may be located in fume hood) 3 % H2O2 solution pieces of Zn metal 4.18 % by mass KMnO4 solution 6 M H2SO4 Commercial H2O2 solution EQUIPMENT TO BE CHECKED OUT 2 Beral disposable plastic pipets 1 Spot test plate (4 hole x 6 hole) tweezers (to remove metal pieces) 2 50 mL beakers SAFETY Avoid contact with KMnO4 (a strong oxidizing agent) and to the acids (HCl, H2SO4) and base (NaOH). If contact occurs, flush with copious amounts of water for 10-15 minutes and notify your instructor. WASTE DISPOSAL Place all wastes in appropriately labeled waste containers located in the fume hood. Chemistry 51 2023-2024 Page 129 OXIDATION-REDUCTION REACTIONS EXPERIMENTAL PROCEDURE: Part 1: Activity Series of Metals and Metal Ions 1. Obtain a spot test plate (4 by 6 deep holes). Place the spot test plate over a white piece of paper. Obtain six pieces each of three different metals: Cu, Zn, and Mg. Place each piece of metal into a separate well. A Diagram for the spot plate is shown below. The 3 different metals are organized by columns. The first column does not contain a metal (it is used to observe the solutions alone). The second column is for copper, the third for zinc, etc. Make initial observations of each metal noting its color, shininess, etc. 2. The five solutions used are organized in rows. The first row will not have any solution (it is for observing the metals alone). The second row is for Cu(NO3)2(aq), etc. React each metal with each of the following solutions: 0.1 M Cu(NO3)2, 0.1 M Zn(NO3)2, 0.1 M Mg(NO3)2, 0.1 M AgNO3, and 6 M HCl by adding enough of the solution to fill the reaction well half-full (about 15-20 drops). Dispense 6 M HCl in the fume hood. Do not put your face close up to the spot test plate. Make immediate observations of any reactions occurring in the wells. Also make initial observations of each solution alone. Spot Plate Diagram: (you may rip this page off and place beneath the spot test plate) No metal Cu Zn Mg No solution HCl ZnSO4 Mg(NO3)2 AgNO3 Cu(NO3)2 Chemistry 51 2023-2024 Page 130 OXIDATION-REDUCTION REACTIONS 3. Allow the reactions in the spot plate to sit at least 10 minutes or more and record observations again. Then determine the combinations that produced reactions and the ones that did not react. 4. Empty the contents of the reaction plate into a large beaker. Ask your instructor if the metal pieces should be saved or if they should be disposed of in a separate waste container. You may use the tweezers to remove the metal pieces if necessary. Dump the wastes from the beaker into the waste container located in the fume hood. Clean the spot plate with tap water, then distilled water and blot dry. Save spot plate for use in part 3. Part 2: Effect Of pH On Oxidation-Reduction Reactions In this part, you will determine the effect of varying the pH on several redox reactions. You may use the following tables to help you identify products of any reactions that occur. Table 1. Various Oxidation States of Elements Name of Species Chemical formula Color in aqueous solution Permanganate ion MnO4-(aq) Purple Manganate ion 2- MnO4 (aq) Green Manganese (IV) oxide MnO2(s) Brownish-black precipitate Manganese (II) ion Mn2+ faint pink to colorless Sulfate ion SO42- Colorless Sulfite ion SO32- Colorless Zinc ion (in acidic solution) Zn2+ Colorless Tetrahydroxo zinc ion (in basic solution) [Zn(OH)4] 2- Colorless Oxygen gas O2(g) bubbles Ox. State of underlined species NOTE: If SO32- is used as a reactant and a chemical reaction is observed, then assume SO32- is converted to SO42- (both species are colorless). If H2O2 is used as a reactant and a gas is produced during the reaction, the identity of the gas is O2. 1. Into each of two, labeled test tubes, add 10 drops of 0.01 M KMnO4 using the pipet provided. Add 2 drops of 6 M HCl to the first test tube and 2 drops of 6 M NaOH to the second test tube. Then add 10-12 drops of 0.1 M Na2SO3 to each of the two test tubes. Use the table below as a guide. Record your observations. Place your wastes temporarily in a large beaker at your Chemistry 51 2023-2024 Page 131 OXIDATION-REDUCTION REACTIONS desk. You will collect all wastes in this part in the beaker and pour the collected wastes at the end of this section into the correct labeled waste container in the fume hood. Test Tube Drops of 0.01 M KMnO4 Drops of 6 M NaOH Drops of 6 M HCl Drops of 0.10M Na2SO3 1A 10 0 2 10-12 1B 10 2 0 10-12 2. Into each of two small, labeled test tubes, add 10 drops of 0.01 M KMnO4. Add 2 drops of 6 M HCl to the first test tube and 2 drops of 6 M NaOH to the second test tube. Then add 2 drops of 3% H2O2 to each of the two test tubes. Use the table below as a guide. Record your observations. Test Tube Label Drops of 0.01 M KMnO4 Drops of 6 M NaOH Drops of 6 M HCl Drops of H2O2 2A 10 0 2 2 2B 10 2 0 2 3. Into each of two small labeled test tubes, add 10 drops of 0.01 M KMnO4. Add 4 drops of 6 M HCl to the first test tube and 4 drops of 6 M NaOH to the second test tube. Then add two pieces of zinc to each of the two test tubes. Use the table below as a guide. You will need to shake the test tubes vigorously and periodically over a 1 hour period of time. Record your observations periodically during this time period. NOTE: if bubbles are observed in addition to other observations, a secondary reaction is occurring and should be balanced separately. Test Tube Label Drops of 0.01 M KMnO4 Drops of Drops of Pieces of zinc metal 6 M NaOH 6M HCl 3A 10 0 4 2 3B 10 4 0 2 4. Ask your instructor if the metal pieces should be saved and/or separated from the solutions. Check with your instructor if the metal pieces should be placed in a separate waste container or in the waste container containing the solutions if the metal pieces are not kept. Carefully pour wastes from Part II into the appropriate waste container(s). Chemistry 51 2023-2024 Page 132 OXIDATION-REDUCTION REACTIONS Part 3: Determination of Percent H2O2 in a Solution of Commercial Hydrogen Peroxide. 1. Record the concentration (mass percent) of KMnO4 from the label on the reagent bottle (NOT the 0.01 M KMnO4 solution!) 2. Obtain two, test tubes and label one as “KMnO4” and the other as “ C. H2O2” (“C” stands for Commercial) and pour about 5 mL of each solution into each test tube, respectively, from the stock bottles and take back to your student bench. 3. Fill a labeled Beral pipet (plastic pipet) to about half full with commercial hydrogen peroxide solution, H2O2, from your test tube. Carefully place the pipet upside down in a preweighed 100 mL beaker to move it to the balance room. Obtain the mass of the pipet containing the H2O2 solution using the 100 mL beaker to hold the pipet (either tare the beaker or account for the mass of the beaker; you must know the mass of the pipet and solution). Do NOT put the pipet directly on the balance pan. NOTE: You will be reweighing these pipets after the reaction is complete so it is imperative that you do not have any losses of solution or spills during the experiment. 4. Fill a second Beral pipet (be sure to label it) to about half full with KMnO4 solution from your test tube and carefully place it upside down in a 150 mL beaker. Obtain the mass of the pipet containing KMnO4 solution using your beaker to hold the pipet. Do NOT put the pipet directly on the balance pan. 5. Add 15 drops of the H2O2 solution from the first Beral pipet into a spot on the test plate. Shake the spot test plate gently back and forth. Then add 3 drops of 6M H2SO4. 6. Add one drop at a time of the KMnO4 solution from the second Beral pipet, into the spot on the test plate with the H2O2. Record your observations of a reaction. What species of manganese is being formed? Continue to add KMnO4 drop-wise until a faint pink color or a brown precipitate persists. The brown precipitate indicates an excess of permanganate, and the reaction is complete and it has reached the endpoint, i.e. it is just past the equivalence point. The reaction at the equivalence point (moles of MnO4- completely react with moles of H2O2) occurs just before formation of the brown precipitate. 7. Measure and record the final mass of each pipet using the beaker to hold the pipet. 8. DO AT LEAST TWO MORE TRIALS. 9. You can use your pipets to suck out the solutions from your spot plate into a beaker for waste disposal if you wish. 10. Rinse both Beral pipets at least twice with DI water and pour rinses and wastes into waste container. Dispose of rinsed Beral pipets in the trash. Chemistry 51 2023-2024 Page 133 OXIDATION-REDUCTION REACTIONS Chemistry 51 2023-2024 Page 134 OXIDATION-REDUCTION REACTIONS DATA ANALYSIS: Part 1: Activity Series of metals and hydrogen gas: 1. Summarize your observations by copying from your notebook pages to the table below (verify with your professor if the following pages will be used for the report): Cu Zn Mg Metal Compound HCl 1 2 3 ZnSO4 4 5 6 8 9 NR Mg(NO3)2 7 NR AgNO3 10 11 12 Cu(NO3)2 13 14 15 NR 2. Circle the boxes which yielded a reaction in the table in question 1. Chemistry 51 2023-2024 Page 135 OXIDATION-REDUCTION REACTIONS 3. Write balanced redox NET IONIC equations for each of the combinations that produced a reaction including physical states. If there was no reaction, write “NR”. In the last column of the table, draw a conclusion about the relative ordering of the metal species in the activity series for the two species being compared. (For example Zn > Cu; note that you can still draw a conclusion from NR) Chemical Reaction Conclusion 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 4. Based on your OBSERVATIONS from the experiment and reactions written in questions 3, determine the relative reactivity of Zn, Ag, Cu, Mg and H2 from strongest reducing agent (most reactive) to weakest reducing agent (least reactive). 5. Does the relative reactivity found from experiment from your answer in question 4 agree with the published reactivity series found in your textbook? _____Explain any discrepancies. Chemistry 51 2023-2024 Page 136 OXIDATION-REDUCTION REACTIONS Part 2: Effect of pH on Oxidation-Reduction Reactions 1. Answer the following questions regarding the KMnO4 and Na2SO3 reactions in acid/base conditions: a. Summarize your observations in the table below. Test Tube Label Drops of KMnO4 Drops of NaOH Drops of HCl Drops of Na2SO3 1A 10 0 2 10-12 1B 10 2 0 10-12 Observations New Species Observed b. Write balanced net ionic equations for all combinations that produced a reaction. c. List the initial and final oxidation states for the reduction of manganese in permanganate by sulfite (a) in acidic solution, and (b) in basic solution. Which type of solution (acidic, basic or neutral) reduced manganese more? Explain your answer. Chemistry 51 2023-2024 Page 137 OXIDATION-REDUCTION REACTIONS 2. Answer the following questions regarding the KMnO4 and H2O2 reactions in acid/base conditions. a. Fill in the following observation table. Test Tube Label Drops of KMnO4 Drops of NaOH Drops of HCl Drops of H2O2 2A 10 0 2 2 2B 10 2 0 2 Observations New Species Observed b. Write balanced net ionic equations for all combinations that produced a reaction. c. List the initial and final oxidation states for the reduction of manganese in permanganate by hydrogen peroxide (a) in acidic solution, and (b) in basic solution. Which type of solution (acidic, basic or neutral) reduced manganese more? Explain your answer. Chemistry 51 2023-2024 Page 138 OXIDATION-REDUCTION REACTIONS 3. Answer the following questions regarding the KMnO4 and zinc reactions in acid/base conditions. a. Fill in the following observation table. Test Tube Label Drops of KMnO4 Drops of NaOH Drops of HCl Pieces of zinc metal 3A 10 0 4 2 3B 10 4 0 2 Observations New Species Observed b. Write balanced net ionic equations for all combinations that produced a reaction. c. List the initial and final oxidation states for the reduction of manganese in permanganate by zinc (a) in acidic solution, and (b) in basic solution. Which type of solution (acidic, basic or neutral) reduced manganese more? Explain your answer. Chemistry 51 2023-2024 Page 139 OXIDATION-REDUCTION REACTIONS Chemistry 51 2023-2024 Page 140 OXIDATION-REDUCTION REACTIONS Part 3: Determination of percent H2O2 in a solution of hydrogen peroxide. 1. Fill in the data/observation table: Trial 1 Trial 2 Trial 3 Concentration of KMnO4 Initial Mass of Pipet containing KMnO4 Solution Final Mass of Pipet containing KMnO4 Solution Initial Mass of Pipet containing H2O2 Solution Final Mass Pipet containing H2O2 Solution Observations of reaction 2. Write a balanced net ionic equation for the reaction that occurred during the titration (which resulted in a clear or pink solution). DO NOT write the net ionic equation of the endpoint reaction. 3. Show one sample calculation for the first trial for the following: a. Mass of KMnO4 solution titrated b. Mass of H2O2 solution reacted c. Using the mass of solution titrated, calculate the mass of KMnO4 titrated. Chemistry 51 2023-2024 Page 141 OXIDATION-REDUCTION REACTIONS d. Determine the moles of KMnO4 titrated. e. Determine the moles of H2O2 reacted. f. Determine the mass of H2O2 reacted. g. Determine the experimental mass percent of H2O2 in the commercial solution. 4. Fill in the following results summary table: Trial 1 Trial 2 Trial 3 Mass KMnO4 solution titrated Mass H2O2 solution titrated Mass KMnO4 reacted Moles KMnO4 reacted Moles of H2O2 reacted Mass of H2O2 reacted Mass of H2O2 solution added Experimental Mass percent of H2O2 solution True mass percent H2O2 from container Chemistry 51 2023-2024 Page 142 OXIDATION-REDUCTION REACTIONS h. Determine the percent relative standard deviation. Comment on the magnitude. i. Obtain the true value of the %(m/m) either from the label on the bottle or from your instructor and determine the percent error. Comment on the magnitude. j. List sources of error in the experiment. POST-LAB QUESTIONS: 1. The following questions relate to the results of Part III of the experiment. a. Based on your experimental results of percent H2O2 discuss whether the label on the commercial product is consistent with your results. Include the calculation of percent error and discuss sources of error in your explanation. b. Commercial hydrogen peroxide contains small amounts of organic compounds, which are added to stabilize the hydrogen peroxide. If these compounds react with the permanganate ion, would the percent H2O2 determined be too high, too low or remain unchanged? Explain. c. If the pipet were wet with water prior to filling it with potassium permanganate, would the percent H2O2 determined be too high, too low or remain unchanged? Explain. Chemistry 51 2023-2024 Page 143 OXIDATION-REDUCTION REACTIONS d. If the pipet were wet with water prior to filling it with hydrogen peroxide, would the percent H2O2 determined be too high, too low or remain unchanged? Explain. Chemistry 51 2023-2024 Page 144 OXIDATION-REDUCTION REACTIONS REFERENCES: Written by Jody Williams Tyler (Reviewed and edited by Janet Truttmann) http://www.files.chem.vt.edu/RVGS/APChem/lab/Experiments/Exp_7-Permanganate-08.html J.A. Beran, Laboratory Manual for Principles of General Chemistry, 8th edition, J.W. Wiley & Sons, Inc., 2007. Chemistry Department, Mt. San Antonio College, Chem 1B Lab Manual, Day and Night Publishing, 1997. Leung, J., “Is It Really 3% Hydrogen Peroxide?”, 1999. Chemistry 51 2023-2024 Page 145 OXIDATION-REDUCTION REACTIONS Chemistry 51 2023-2024 Page 146 ELECTROCHEMISTRY AND CELL POTENTIALS OBJECTIVES: • Construct galvanic cells using a variety of electrodes and solutions and measure their cell potentials • Use the Nernst Equation and reference values of standard reduction potentials to calculate predicted cell potentials and compare to measured cell potentials • Explore the effect of concentration on cell potentials including non-ideal behavior • Use a measured cell potential to experimentally determine the Kf for the formation of the [Cu(NH3)4]2+(aq) complex ion INTRODUCTION: Electrochemistry is the study of oxidation-reduction reactions for which the transfer of electrons has been engineered to flow through an external circuit. Controlling the redox reactions in this way provides a number of very important advantages: a. The electrochemical potentials (cell voltages) of different materials/solutions can be measured to get information about their relative oxidizing/reducing power. b. The concentration dependence of cell voltages can be used to determine concentrations of redox active ions in solution. c. Electrochemical potential energy can be stored in batteries and used to do work. In this experiment, you will construct a number of different galvanic (spontaneous) cells and measure their cell potentials. The potential of a cell depends on the specific materials of which it is made as well as the concentrations of the redox active species in solution. The Nernst Equation (eq. 1) defines this relationship E cell = E ocell − 0.0592 log Q n (1) where Ecell is the measured cell voltage, Eocell is the cell voltage under standard state conditions, n is the number of electrons transferred in the overall balanced redox reaction, and Q is the ο reaction quotient from the balanced redox equation. Eocell is the standard reduction potential of the cathode minus the standard reduction potential of the anode. Standard reduction potentials can be found in reference tables in your textbook. In order to explore a variety of systems quickly and with minimal chemical waste, the galvanic cells will be constructed using spot plates to hold the electrodes and cell solutions. The salt bridges will be made by soaking strips of filter paper in potassium nitrate solution. The cell voltages will be measured by connecting the alligator clips from the Vernier voltage probe to each electrode and reading the voltage on the laptop display. In Part 1 of this experiment, you will use copper, zinc, and graphite electrodes and solutions of CuSO4(aq), ZnSO4(aq), and I-/I2(aq). The voltages of all combinations of these half cells will be measured and compared to their theoretical values. Note that the graphite electrodes Chemistry 51 2023-2024 Page 147 ELECTROCHEMISTRY AND CELL POTENTIALS are inert—they do not undergo oxidation or reduction—but provide a solid material that conducts electrons. The electrochemical reaction between I-(aq) and I2(aq) occurs in the aqueous solution at the surface of the graphite electrodes. In Part 2 of this experiment, you will observe the dependence of the cell potential on solution concentration for two systems. A concentration cell is a cell in which both the anode compartment and cathode compartment comprise the same materials but at different concentrations. For these cells, the standard cell potential, Eocell, is zero because the anode reaction is the exact opposite of the cathode reaction. The cell voltage of a concentration cell derives from the difference in solution concentrations—the log Q term in the Nernst Equation. In Part 3 of this experiment, you will use a measured cell potential to determine the concentration of uncomplexed Cu2+(aq) ions in a solution of CuSO4(aq) that has been reacted with NH3(aq) to form the [Cu(NH3)4]2+(aq) complex ion (equation 2). By constructing an ICE table of initial and equilibrium concentrations of each species, a value for the K f can be determined. 2+ Cu2+(aq) + 4NH3(aq) ↔ [Cu(NH3)4]2+(aq) Kf = [Cu(NH 3 ) 4 ] [Cu 2+ ] [NH 3 ]4 (2) ο PRE-LAB QUESTIONS: 1. Define the following terms: a. anode b. cathode c. salt bridge 2. Write the reduction half reactions for the following species and look up their standard reduction potentials in your textbook: a. Zn2+(aq) b. Cu2+(aq) (reduction to the solid metal) π c. I2(aq) (πΈπππ of I2(aq) = +0.62 V; ref. Quantitative Chemical Analysis, 7th ed., W.H. Freeman, New York, 2007) 3. In a cell constructed between a compartment containing a zinc electrode immersed in a 0.10 M ZnSO4(aq) solution and a compartment containing a copper electrode immersed in a 0.10 M CuSO4(aq) solution, a. b. c. d. which electrode will be the anode? what is the standard cell potential, Eocell? what is the theoretical cell potential, Ecell, with these concentrations? write the line notation for this cell Chemistry 51 2023-2024 Page 148 ELECTROCHEMISTRY AND CELL POTENTIALS CHEMICALS AND MATERIALS 1 M CuSO4(aq) 0.1 M CuSO4(aq) 0.1 M ZnSO4(aq) 0.1 M KI, 0.001 M I2 (aq) 0.01 M KI, 0.001 M I2(aq) 3 M H2SO4(aq) 6 M NH3 0.1 M KNO3(aq) copper squares zinc squares copper wire graphite pencil leads filter paper cut in quarter inch strips EQUIPMENT TO BE CHECKED OUT Laptop Vernier voltage probe with alligator clips Spot plate 25 mL beakers (two per student) 2 mL volumetric pipet Pipet pump Tweezers SAFETY Goggles must be worn in the laboratory. WASTE DISPOSAL All waste should be disposed in the labeled waste container for this experiment. EXPERIMENTAL PROCEDURE: Part 1: Exploring the Cell Potentials of Different Materials In this part of the experiment, you will measure the cell potentials of several different cells and compare your results to those predicted by the standard reduction potentials and the Nernst Equation. 1. Obtain a laptop, spot plate, a Vernier voltage probe, 2 pieces of copper metal, 2 pieces of zinc metal, and 2 graphite mechanical pencil leads from your instructor. Fill each well of the spot plate about half full with the solutions as shown in Figure 1. 2. Take 3 strips of filter paper and place them on a watch glass. Wet them completely with 0.1 M KNO3(aq). Use tweezers to handle the wet strips. Place each end of the wet strip in the solutions in the spot plates as shown in Figure 1 to form the salt bridges for the three cells. Chemistry 51 2023-2024 Page 149 ELECTROCHEMISTRY AND CELL POTENTIALS Cell #1 0.1 M CuSO4 0.1 M ZnSO4 Cell #2 0.1 M CuSO4 0.1 M I-, 0.001M I2 Cell #3 0.1 M ZnSO4 0.1 M I-, 0.001M I2 Figure 1: Organization of Spot Plate for Part 1. 1. Turn on your voltage probe by pressing the power button once. The Bluetooth LED will blink red. 2. Turn on the laptop and log in (or you can use your own mobile phone). Open the Graphical Analysis software. 3. Click on DATA SENSOR COLLECTION. Choose your sensor from the list of DISCOVERED WIRELESS DEVICES (your sensor’s ID is located near the barcode on the sensor) and then click CONNECT. . The Bluetooth LED will blink green when it is successfully connected. Click DONE to enter data-collection mode. Chemistry 51 2023-2024 Page 150 ELECTROCHEMISTRY AND CELL POTENTIALS 4. Click on the on the screen to check the battery power on your device. (If the battery level is less than 20%, ask your instructor if you should exchange probes or connect your probe to the laptop with a USB cable that will also simultaneously charge the probe.) 5. Click on the display option. icon in the upper right corner of the screen. Choose METER as the 6. Clip the red and black alligator clips together as shown below. Click on the large red bar that appears across the screen to pull up another menu. Choose ZERO to zero out the voltage. Chemistry 51 2023-2024 Page 151 ELECTROCHEMISTRY AND CELL POTENTIALS 7. Vigorously wipe the metal pieces with paper towel before using to remove oxide coatings. 8. Connect one alligator clip to a piece of copper metal and place the copper metal strip into the first well in your spot plate for cell #1 (0.1 M CuSO4 solution) being careful not to let the alligator clips touch the solution. Connect the other alligator clip to a piece of zinc metal and immerse the zinc into the adjacent 0.1 M ZnSO4 solution. (Caution: the alligator clips need to be kept dry for accurate results. Do not let the clips touch the solutions. If the clips do get wet, dry them with a paper towel before proceeding.) Vernier Probe Figure 2: Connecting the Vernier Voltage Probe 9. Observe the voltage on the laptop display. If the voltage displayed is negative, reverse the orientation of the clips (but still keeping the copper metal in the CuSO4 solution and the zinc metal in the ZnSO4 solution) to achieve a positive voltage. The black alligator clip corresponds to the anode and the red alligator clip corresponds to the cathode. Record the measured voltage and note which electrode is the anode in your notebook. 10. Repeat this process to measure the cell potentials for cells #2 and #3. In cell #2, use a fresh piece of copper in the CuSO4 solution and a graphite pencil lead as an electrode in the KI/I2 solution. In cell #3, use a fresh piece of zinc in the ZnSO4 solution and a graphite pencil lead as the electrode in the KI/I2 solution. 11. With the alligator clips connected, remove the salt bridge from cell #3 and observe what happens. Record the results in your notebook. Part 2: Dependence of Cell Potentials on Concentration In this part of the experiment, you will measure the cell voltage for two different concentration cells. The I-/I2 cell displays the expected concentration dependence. The Cu/CuSO4 system, however, shows unexpected results. The measured cell potential in each case reflects the concentrations of “free” ions in solution. Cu2+ forms a variety of complexes with OH- in water even at neutral pHs. The formation of these complexes results in “unexpected” cell potentials because the concentration of free Cu2+ is not equal to the value on the label of the solution. The expected results will be restored by adding acid to each half cell to eliminate these complex ions. Chemistry 51 2023-2024 Page 152 ELECTROCHEMISTRY AND CELL POTENTIALS 1. In two new adjacent compartments of your spot plate, place fresh solutions of 0.1 M KI/0.001 M I2 and 0.01 M KI/0.001 M I2. Connect the compartments with a fresh salt bridge. Place graphite electrodes in each cell and connect the alligator clips to achieve a positive voltage. Record the voltage and note which electrode is the anode. 2. In two new adjacent compartments of your spot plate, place fresh solutions of 0.1 M CuSO4(aq) and 1 M CuSO4(aq). Connect the compartments with a fresh salt bridge. Place a piece of copper metal in each compartment. Connect the red clip to the copper strip in the 1 M CuSO4 solution and the black clip to the copper strip in the 0.1 M CuSO4(aq) solution. Record the observed voltage. 3. Add 2 drops of 3 M H2SO4 to each CuSO4 solution from step 2 to eliminate the copper hydroxide complexes. Wait for the voltage to stabilize and record the new voltage. Use this second recorded voltage as your experimental voltage for this cell. 4. Clean and return the metal pieces and graphite electrodes to your instructor. The salt bridges may be disposed of in the trash. Empty the solutions from your spot plate into a waste beaker and dispose the solutions in the labeled waste container. Clean your spot plate and return it to your instructor. Part 3: Using Measured Cell Potentials to Determine the Kf of the [Cu(NH3)4]2+ Complexation Reaction 1. Obtain two 25 mL beakers and 2 pieces of copper wire (about 4 inches each). Condition your 10 mL volumetric pipet with 0.1 M CuSO4(aq) solution. Transfer 10.00 mL of 0.1 M CuSO4(aq) solution to each beaker. Place an approximately 4 inch length of copper wire in each beaker (coil the end a bit so that the end stays submersed in the solution). Place one end of a strip of filter paper that has been wet with 0.1 M KNO3 in each beaker. 2. Connect the alligator clips from the Vernier voltage probe to the copper wires. Record the initial cell voltage. 3. Remove the anode and salt bridge from the anode beaker and take the anode beaker to the fume hood to add the ammonia solution. Obtain a small amount of 6 M NH3(aq) in a test tube to condition your 2-mL volumetric pipet in the fume hood, then and add 2.00 mL of 6 M NH3(aq) to the anode beaker. Swirl the beaker gently to mix the solution. Return the beaker to your station and re-insert the anode and salt bridge. CAUTION: ammonia has a strong odor, avoid inhaling the fumes. Record your qualitative observations of the chemical reaction. Read and record the cell voltage while gently swirling the solution. Immediately dispose of the solution in the appropriate waste container. 4. Clean and return the copper wires. 5. Turn off the voltage probe by pressing and holding the power button for three seconds (the red LED will stop blinking). Return the probe and laptop to your instructor. Chemistry 51 2023-2024 Page 153 ELECTROCHEMISTRY AND CELL POTENTIALS DATA ANALYSIS: Part 1: 1. Exploring the Cell Potentials of Different Materials For each cell measured in Part 1, a. identify the anode electrode b. identify the cathode electrode c. write the balanced oxidation half reaction and its standard oxidation potential d. write the balanced reduction half reaction and its standard reduction potential e. write the overall balanced redox reaction and its standard cell potential f. write the line notation for the cell g. calculate the theoretical cell voltage using the standard cell potential and the solution concentrations h. report the experimentally measured cell voltage i. calculate the % error between the theoretical cell voltage and the measured cell voltage (Note: recall that the I2 used in this experiment is aqueous, not solid, so use the π provided value of πΈπππ I2(aq) = +0.62 V.) 2. Which metal is a better reducing agent, Cu or Zn? 3. Why is graphite used as the electrode material in the I-/I2 cells? Part 2: Dependence of Cell Potentials on Concentration 4. For each cell measured in Part 2, a. identify the anode electrode b. identify the cathode electrode c. write the balanced oxidation half reaction and its standard oxidation potential d. write the balanced reduction half reaction and its standard reduction potential e. write the overall balanced redox reaction and its standard cell potential f. write the line notation for the cell g. calculate the theoretical cell voltage using the standard cell potential and the solution concentrations h. report the experimentally measured cell voltage i. calculate the % error between the theoretical cell voltage and the measured cell voltage Chemistry 51 2023-2024 Page 154 ELECTROCHEMISTRY AND CELL POTENTIALS Part 3: Using Measured Cell Potentials to Determine the Kf of the Cu(NH3)42+ Complexation Reaction 5. Write the complex ion formation reaction and its corresponding equilibrium constant expression (see introduction). What visual evidence of this chemical reaction did you observe? 6. Use the Nernst Equation and the measured cell voltage to calculate the concentration of uncomplexed Cu2+ in the anode compartment of the cell after reaction with NH3. This is the equilibrium concentration of the Cu2+ ion that will be used to calculate Kf for the complexation reaction. 7. Calculate the initial concentration of Cu2+ in the anode compartment before reaction, but after dilution by the additional 2 mL of added solution. 8. Calculate the initial concentration of NH3 in the anode compartment before reaction, but after dilution into the CuSO4 solution. 9. Create an ICE table, inserting the “initial concentration” values calculated in steps 7 and 8 (assume initial concentration of the complex ion is zero). Use “x’s” in the “change” row to show how the concentrations change to reach equilibrium. 10. Note that the equilibrium concentration of Cu2+ determined in step 6 allows you to determine the value of “x,” in your ICE table and thus the values of all other equilibrium concentrations. 11. Using your equilibrium constant expression and calculated equilibrium concentrations, calculate the experimental value of Kf . 12. Compare your experimental result to the “true value” of Kf (1.7x1013) by calculating a percent error. Chemistry 51 2023-2024 Page 155 ELECTROCHEMISTRY AND CELL POTENTIALS POST-LAB QUESTIONS: 1. Predict how the Ecell for the copper/zinc cell in part 1 would change (increase, decrease, remain the same) if a. the concentration of the anode solution were changed to 1 M b. the concentration of the cathode solution were changed to 1 M c. a larger piece of metal were used 2. Calculate the Ecell for the copper concentration cell in part 2 if 0.01 M CuSO4 were used instead of 0.1 M CuSO4. 3. In part 3, how would Ecell change (increase, decrease, remain the same) if 2.00 mL of 6.0 M HCl were added to the copper ammonia complex solution? Write a balanced chemical equation to support your answer. REFERENCES: Written by Janet Truttmann, May 2011 Revised July 2022 Chemistry 51 2023-2024 Page 156 BONDING, STRUCTURE, AND PHYSICAL PROPERTIES OF ORGANIC COMPOUNDS OBJECTIVES: • build molecular models of simple organic compounds containing various functional groups • apply concepts of molecular polarity and intermolecular forces to make predictions about the relative properties of organic molecules • determine functional groups present in pre-built models of organic molecules INTRODUCTION: Organic compounds are molecules containing carbon. Organic compounds range from very small molecules like methane (CH4) to enormous ones like the proteins and DNA found in our bodies. Chemists group organic compounds by which “functional groups” they contain. Functional groups are specific arrangements of atoms that commonly appear in organic molecules. Table 6 shows the organic functional groups we will consider in this activity. Organic molecules utilize covalent bonding and as such are well described by the Lewis bonding model. In this activity you will construct models of simple organic molecules containing the various functional groups and answer questions about their structure, polarity and predicted properties. You will also observe pre-built models of more complicated organic molecules and determine which functional groups they contain. The important concepts used in this experiment include the following: • • • • • • • • • • • drawing Lewis structures for covalent molecules determining electron arrangements/angles around central atoms in covalent molecules determining molecular geometries around central atoms using the Valence Bond Model to describe bonding in covalent molecules (hybridized orbitals) definition of electronegativity determining polarity of covalent bonds determining polarity of covalent molecules identifying intermolecular forces for molecules making predictions about the relative magnitude of physical properties for covalent molecules based on structure identifying functional groups for organic molecules representing organic molecules using molecular formulas, condensed structural formulas, Lewis structures, skeletal formulas, and three-dimensional shape representations These skills/concepts have been covered in your textbook in the chapters on bonding (Chapters 7, 8, and 10 in Chem 50) and in the chapter on organic chemistry (Chapter 20 in Chem 51). Key aspects are summarized/reviewed here. Chemistry 51 2023-2024 Page 157 BONDING, STRUCTURE, & PHYSICAL PROPERTIES OF ORGANIC COMPOUNDS Shapes of Covalent Molecules Recall that the shapes of covalent molecules are determined by the number of electron groups around the central atom and whether the electron groups are bonding electrons or lone pairs. Table 1 shows the geometries for each possible combination of bonding and lone pairs based on the Lewis Structure and VSEPR models of bonding. Note that organic molecules often contain more than one “central” atom. The geometries and angles below can be applied to each central atom to determine the overall arrangement of the molecule. Table 1: VESPR Model Total # Electron Groups around central atom Electron Group Arrangement (name and diagram) Bond Angle # Bonds # Lone Pairs 2 linear 180Λ 2 0 3 0 2 1 Molecular Structure (name and diagram) linear trigonal planar trigonal planar 120Λ 3 bent tetrahedral tetrahedral 4 109.5Λ 4 0 3 1 2 2 trigonal pyramid bent Valence Bond Model The Valence Bond Model views covalent bonds as constructive overlap of singlyoccupied atomic orbitals that have been optimized for bonding through “hybridization.” Hybrid orbitals can also house the lone pair electrons on a central atom. Chemistry 51 2023-2024 Page 158 BONDING, STRUCTURE, & PHYSICAL PROPERTIES OF ORGANIC COMPOUNDS # Electron Groups on “Central” Atom Table 2. Valence Bond Model Hybridization of # Hybrid Orientation of Bonding Lobes “Central” Atom Orbitals 2 sp 2 Linear (180o) 3 sp2 3 Trigonal planar (120o) 4 sp3 4 Tetrahedral (109.5 o) Orbitals that overlap along the line between two atoms form sigma (ο³) bonds. Unhybridized p orbitals can overlap above and below the bonded atoms to form pi (ο°) bonds. Double bonds are comprised of one sigma bond and one pi bond. Triple bonds are comprised of one sigma bond and two pi bonds. An atom that is sp hybridized will have two sp hybrid orbitals oriented at a 180o angle and two remaining unhybridized p orbitals available for pi bonds. The diagram below shows the valence bond model for acetylene (HC≡CH). The picture on the left shows the overlap of the orbitals and the picture on the right shows the resulting sigma and pi bonds. Each carbon atom in acetylene is sp hybridized. The two C-H sigma bonds are formed by the overlap of the hydrogen 1s orbitals with the sp hybridized C orbitals. The C-C sigma bond is formed by the overlap of the sp hybridized orbitals on the two carbons. The two C-C pi bonds are formed by the overlap of the unhybridized p orbitals on the two carbon atoms. Bond Type C-H ο³ C-C ο³ C-C ο° Orbital Overlap Csp-Hs Csp- Csp Cp- Cp # 2 1 2 Molecular Polarity The polarity of a covalent bond is determined by the difference in electronegativities of the bonded atoms. Bonded atoms that have the same electronegativities (or an electronegativity difference of 0.4 or less) form non-polar bonds. If two bonded atoms have electronegativities that differ by more than 0.4, then the resulting bond is polar. Table 3 shows the electronegativities of the elements used in this lab. Recall that molecular polarity is determined Chemistry 51 2023-2024 Page 159 BONDING, STRUCTURE, & PHYSICAL PROPERTIES OF ORGANIC COMPOUNDS by the polarity of the bonds as well as the molecular shape. Molecules that have polar bonds and are also non-symmetric will be polar. However, molecules that either have no polar bonds, or have polar bonds but are symmetric, will be non-polar (SNAP—symmetric non-polar, asymmetric polar). Organic molecules that have only C—C and C—H bonds are non-polar. But organic molecules containing O, S, P, N, or halogen atoms are generally polar. Table 3. Electronegativities of Atoms 2.1 H 2.0 B 2.5 C 1.8 Si 3.0 N 2.1 P 3.5 O 2.5 S 4.0 F 3.0 Cl 2.8 Br 2.5 I Predicting Physical Properties of Organic Compounds In this lab, you will be asked to predict the relative values of properties such as melting point and boiling point for various organic compounds. The values of these properties depend on the strength of intermolecular forces between the molecules. The strength of the intermolecular forces depends mostly on the polarity of the molecules . Table 4. Intermolecular Forces Between Covalent Molecules Force Description Relative Strength LondonDispersion Attractive forces between non-polar molecules due to Coulombic attraction between an instantaneous dipole in an atom or molecule and an induced dipole in a neighboring atom or molecule weakest Attractive forces between polar molecules due to the Coulombic attraction between permanent opposite partial charges of dipoles. intermediate Dipole-Dipole Hydrogen Bonding Attractive forces between regions of molecules containing N-H, O-H or FH covalent bonds with similar regions of other molecules. Chemistry 51 2023-2024 (but strength increases with size of molecule) strongest Page 160 BONDING, STRUCTURE, & PHYSICAL PROPERTIES OF ORGANIC COMPOUNDS Table 5. Dependence of Physical Properties on Strength of Intermolecular Forces Property Description Dependence melting point The temperature at which a substance converts from the solid to the liquid phase. increases with increasing strength of intermolecular forces boiling point The temperature at which the vapor pressure of a liquid is equal to the surrounding atmospheric pressure. increases with increasing strength of intermolecular forces vapor pressure The partial pressure of the gas phase of a substance in contact with the liquid phase in a closed container. Vapor pressure is temperature dependent. decreases with increasing strength of intermolecular forces solubility Solubility refers to the amount of substance that will dissolve in a given amount of solvent. Solvents can be polar, like water, or non-polar like hexane. “Like dissolves like” means that polar solutes dissolve better in polar solvents and non-polar solutes dissolve better in non-polar solvents. Representations of Organic Molecules There are several different ways that a given organic molecule can be represented ranging from simple molecular formulas to molecular models showing three-dimensional shapes. Descriptions of the various ways of depicting organic molecules are shown in Table 6 with examples for ethanol and acetic acid. Chemistry 51 2023-2024 Page 161 BONDING, STRUCTURE, & PHYSICAL PROPERTIES OF ORGANIC COMPOUNDS Table 6. Representations of Organic Molecules: Molecular Formula Lewis Structure • symbols used for each element • carbon listed first followed by hydrogen and then other elements in alphabetical order • show element symbols for all atoms • use lines to show bonds between atoms (single, double, triple) • use pairs of dots to show lone pair electrons Examples ethanol: C2H6O acetic acid: C2H4O2 ethanol: •• •• acetic acid: H O H •• •• Description C C •• O •• H H Condensed Structural Formula Skeletal Formula Molecular Shape Drawings • write each carbon and attached atoms as a group • can use lines to show connectivity of carbons ethanol: CH3-CH2-OH acetic acid: CH3-COOH • each bond between carbons or ethanol: between carbon and another atom (except hydrogen) is represented as a line (or 2 lines if double bond, etc.) • carbons are represented as a vertex of 2 lines acetic acid: • hydrogens attached to carbons are not shown • N, O, Cl, etc. are shown explicitly with their attached hydrogens if any • use symbols to represent atoms • use lines to represent bonds (single, double, triple) • use wedges and dashes to show three-dimensional shape of molecule OH O OH H H ethanol: O C H H C H H O acetic acid: H H Chemistry 51 2023-2024 H C C O H Page 162 BONDING, STRUCTURE, & PHYSICAL PROPERTIES OF ORGANIC COMPOUNDS Organic Functional Groups Table 7 shows the various organic functional groups. The lines denote bonds to the “rest of the molecule.” In most cases, this could either be another carbon or a hydrogen. In cases where it must be a carbon, we have shown that as β• Table 7. Organic Functional Groups Functional Group Name haloalkane Functional Group Representation •βX (where X = F, Cl, Br, I) alkene C C alkyne C C aromatic or alcohol •βOH ether •βOβ• thiol •βSH O aldehyde C H ketone carboxylic acid ester amine amide Chemistry 51 2023-2024 Page 163 BONDING, STRUCTURE, & PHYSICAL PROPERTIES OF ORGANIC COMPOUNDS Organic Molecules in Biochemistry: As “living organisms,” our bodies contain many organic compounds. Some important classes of organic compounds in our bodies include proteins (made from amino acids), sugars and carbohydrates, nucleic acids found in our DNA, and lipids. An understanding of these types of compounds is essential to understanding how our bodies function. The structures of these important biomolecules are described briefly here. Proteins Proteins perform many functions in our bodies and are made up of long chains of amino acids. Amino acids are small molecules that contain a carboxylic acid functional group, an amine functional group, and a side chain that varies. In nature there are 20 common amino acids. Chains of amino acids are formed when the carboxylic acid end of one amino acid reacts with the amine end of another amino acid to form an amide bond with the release of H 2O. side chain R H2N CH O carboxylic acid C OH amine CH3 H2N CH O C O OH amino acid (alanine) + O CH3 O H2N CH2 C OH amino acid (glycine) H2N CH C NH CH2 C OH + H2O dipeptide (alanylglycine) Carbohydrates Carbohydrates are a class of organic molecules that have ketones or aldehydes with multiple alcohol groups. Carbohydrates are the most abundant type of organic molecules in nature. Carbohydrates are classified as monosaccharides, disaccharides, or polysaccharides depending on the number of simple sugars they contain. Monosaccharides, like glucose, are the simplest sugars and generally have the formula Cn(H2O)n where n can be any whole number. Monosaccharides can exist as open chain molecules or in a ring structure. Disaccharides contain two monosaccharide units that have been joined together in a chemical reaction that involves loss of water. Unlike monosaccharides, disaccharides can thus be broken down, or hydrolyzed, to form two monosaccharides. An example of a disaccharide is sucrose, or table sugar, which is the dehydration product of the monosaccharides glucose and fructose. As the name implies, polysaccharides are carbohydrates that contain multiple monosaccharide units. Examples include starch and cellulose. The structures of fructose, glucose, and sucrose are shown on the next page. Chemistry 51 2023-2024 Page 164 BONDING, STRUCTURE, & PHYSICAL PROPERTIES OF ORGANIC COMPOUNDS H OH H O H C C H2C C O H C OH HO C H HO C H H C OH H C OH H C OH H C OH H C H C OH H C OH HO C H C H O H H C C OH OH OH H D-glucose (open chain) D-fructose H OH ο‘-D-glucose (ring structure) HO H2C C H H C OH HO C H OH CH2 O C H C OH O H C O H H OH C C OH C H CH2 OH sucrose Nucleic Acids Nucleic acids are a class of organic compounds that contain long chains of nucleotides. Two common nucleic acids are deoxyribonucleic acid (DNA) and ribonucleic acid (RNA). Nucleotides are made up of a five-carbon sugar group, a phosphate group, and a basic group. A generic structure of a nucleotide is shown below. O O sugar - O P O O N base - generic nucleotide Chemistry 51 2023-2024 Page 165 BONDING, STRUCTURE, & PHYSICAL PROPERTIES OF ORGANIC COMPOUNDS Nucleotides differ in the type of base and sugar groups. Nucleic acids are formed when an alcohol group on the sugar of one nucleotide reacts with the phosphate group on another nucleotide to form a phosphodiester bond. DNA molecules can consist of millions of nucleotides joined together in this way. RNA molecules are smaller, but still contain several thousand nucleotides. DNA molecules carry the genetic information that directs the growth and activities of our cells. RNA molecules are responsible for directing the synthesis of proteins in our bodies. Lipids Lipids are a class of organic compounds that are insoluble in water, but soluble in organic solvents. There are several classes of lipids including fatty acids, fats, oils, waxes, and steroids. Fatty acids are a group of compounds that contain a long carbon chain (10-20 carbons long) attached to a carboxylic acid group. If all the carbon-carbon bonds are single bonds, the fatty acids are known as saturated fatty acids. Unsaturated fatty acids contain C=C bonds. Fatty acids are a component of many other types of lipids. The structure of stearic acid, which has 18 carbons, is shown below. O CH2 H3C CH2 CH2 CH2 CH2 CH2 CH2 CH2 CH2 CH2 CH2 CH2 CH2 CH2 CH2 C CH2 OH stearic acid Chemistry 51 2023-2024 Page 166 Bonding, Structure, and Physical Properties of Organic Compounds Name _________________________ PRE-LAB QUESTIONS: 1. Match each functional group to its description. ____ halocarbon a) contains a carbon-carbon double bond ____ aldehyde b) contains a carbon-carbon triple bond ____ ester c) six-membered carbon ring with alternating double bonds ____ amine d) contains an oxygen-hydrogen bond ____ ketone e) contains an oxygen between two carbon atoms ____ amide f) contains sulfur ____ alkyne g) contains a carbonyl group with one hydrogen bonded to the carbon ____ thiol h) contains a carbonyl group in which the carbon is bonded to two other carbons ____ aromatic i) contains a carbonyl group in which the carbon is bonded to a hydroxyl group ____ alkene j) contains a carbonyl group in which the carbon is bonded to an oxygen which is bonded to another carbon ____ alcohol k) contains a nitrogen bonded to carbons and/or hydrogens ____ ether l) contains a carbonyl group in which the carbon is bonded to a nitrogen ____ carboxylic acid m) contains a halogen 2. In each of the following molecules, put a circle around the functional group and name the group. a) H3C b) CH2 CH O CH2 CH2 H3C ______________________ d) C H3C CH2 H _____________________ O c) C CH3 CH2 CH3 O ______________________ Chemistry 51 2023-2024 _____________________ Page 167 BONDING, STRUCTURE, & PHYSICAL PROPERTIES OF ORGANIC COMPOUNDS 3. A bond is (circle) electronegativities. polar / non-polar if the bonded atoms have different 4. A molecule is (circle) polar / non-polar if it contains polar bonds and is symmetrical. 5. Match the type of molecule with its strongest intermolecular force. _____ polar molecule a. London dispersion _____ non-polar molecule b. hydrogen bonding _____ polar molecule with –OH group c. dipole-dipole 6. Rank the following intermolecular forces from strongest to weakest (assuming similar molecular size). a. London dispersion b. hydrogen bonding c. dipole-dipole Chemistry 51 2023-2024 Page 168 BONDING, STRUCTURE, & PHYSICAL PROPERTIES OF ORGANIC COMPOUNDS PROCEDURE: Part A: Building Models The report sheets for this activity show the condensed structural formulas for the covalent compounds that you will build with your partner using the molecular modeling kits that you check out from your instructor. The modeling kits contain the following: • 6 black balls (4-hole) representing carbon atoms • 2 blue balls (4-hole) representing nitrogen atoms • 3 red balls (4-hole) representing oxygen atoms • 4 green balls (4-hole) representing halogen atoms • 2 yellow balls (6-hole) representing sulfur • 1 purple ball (5-hole) representing phosphorus • 6 small white balls (1-hole) representing hydrogen atoms • 10 short gray single bond connectors • 10 longer gray flexible connectors for making double and triple bonds • 14 white plugs to represent lone pair electrons • a tool for disconnecting bonds Since some of the molecules require more parts than are in one kit, share pieces with your partner to complete the models. However, when you return the kits to your instructor, make sure that all pieces have been disconnected and the kits contain all the items listed above. You will construct models of each compound based on its Lewis structure (electron dot structure). In your final models, every hole should be filled with either a lone pair plug or gray bonding connector. Correct models will show the correct bond angles and molecular shapes of the molecules. (Note, do not use any of the 6-hole balls for this activity. For the model that includes sulfur, use one of the green balls to represent sulfur rather than the yellow ball.) For each molecule assigned, complete the following steps IN ORDER and record the requested information on the report sheet. 1. Identify which organic functional group is present by circling the group in the condensed structural formula column and writing the name of the functional group in column 2. 2. Determine the total number of valence electrons in the molecule and draw the Lewis structure for the molecule. 3. Determine the hybridization of any “central” atoms. 4. Build the molecular model according to your Lewis structure and draw a 3-D picture of the molecule that matches your model. Label the angles in your drawing (109.5º, 120º, 180º) 5. Draw the skeletal formula of the molecule 6. Determine whether or not the molecule is polar. Chemistry 51 2023-2024 Page 169 BONDING, STRUCTURE, & PHYSICAL PROPERTIES OF ORGANIC COMPOUNDS Part B: Identifying Functional Groups in Pre-built Models Your instructor will place a number of pre-built models on the bench tops. Examine the models and complete the report sheet for this section. Chemistry 51 2023-2024 Page 170 Report Sheets for Bonding, Structure, and Physical Properties of Organic Compounds Part A: Building Models 1 Condensed Structural Formula (Circle the Functional Group) 2 Functional Group Name *pentane CH3CH2CH2CH2CH3 alkane Name _________________________ 3 4 5 Lewis Structure Hybridization of Each “Central” Atom Molecular Drawing (show 3-D structure and label angles) H H H H H H C1 C2 C3 C4 C5 H H H H H H C1 = sp3 C2 = sp3 C3 = sp3 C4 = sp3 C5 = sp3 all angles 109.5o H H H H C4 H H C2 C1 C3 C5 H H H H H 6 7 Skeletal Formula Molecular Polarity? (polar/ non-polar) non-polar H CH3-CH=CH2 *ethanol CH3CH2− OH *acetic acid O H3C C OH or CH3−COOH Chemistry 51 2023-2024 Page 171 1 2 Condensed Structural Formula (Circle the Functional Group) Functional Group Name 3 4 5 Lewis Structure Hybridization of Each “Central” Atom Molecular Drawing (show 3-D structure and label angles) 6 7 Skeletal Formula Molecular Polarity? (polar/ non-polar) CH3−CH2−NH2 H3C C C CH3 CH3−SH O H3C C NH CH3 Chemistry 51 2023-2024 Page 172 1 2 Condensed Structural Formula (Circle the Functional Group) Functional Group Name 3 4 5 Lewis Structure Hybridization of Each “Central” Atom Molecular Drawing (show 3-D structure and label angles) 6 7 Skeletal Formula Molecular Polarity? (polar/ non-polar) O H3C C O CH3 or CH3−COO−CH3 O H3C C H H H C C C H H C C C H H CH3−O−CH3 Chemistry 51 2023-2024 Page 173 1 2 Condensed Structural Formula (Circle the Functional Group) Functional Group Name 3 4 5 Lewis Structure Hybridization of Each “Central” Atom Molecular Drawing (show 3-D structure and label angles) 6 7 Skeletal Formula Molecular Polarity? (polar/ non-polar) CH2Cl2 *acetone O H3C C CH3 Chemistry 51 2023-2024 Page 174 Part B: Identifying Functional Groups From Pre-Built Models Name of Compound Molecular Drawing Skeletal Formula/Line Drawing Names of Functional Groups Properties Chemistry 51 2023-2024 Page 175 [This page intentionally blank] Chemistry 51 2023-2024 Page 176 Bonding, Structure, and Physical Properties of Organic Compounds Name _________________________ POST-LAB QUESTIONS: 1. What type of intermolecular forces are strongest for the following molecules (refer back to *’d molecules above)? a. *pentane (CH3CH2CH2CH2CH3) b. *ethanol (CH3CH2OH) c. *acetone (CH3COCH3) d. *acetic acid (CH3COOH) 2. Predict the relative water solubilities of the compounds in question 1 by listing them in order from least soluble to most soluble using the symbol < between compounds. If two molecules are expected to have similar solubilities to each other, separate them with a comma. 3. Predict the relative vapor pressures of the compounds in question 1. 4. Predict the relative boiling points of the compounds in question 1. 5. Use the website https://pubchem.ncbi.nlm.nih.gov to complete the following table. Were your predictions accurate? Compound Water Solubility (mg/L) Vapor Pressure at 25oC (mm Hg) Normal Boiling Point (oC) pentane ethanol acetone acetic acid Chemistry 51 2023-2024 Page 177 6. Ethanol (CH3CH2OH) is miscible (completely soluble) in water, but hexanol (CH3CH2CH2CH2CH2CH2OH) is only slightly soluble in water. Why do you think ethanol is more soluble in water than hexanol even though they are both alcohols? 7. Use the valence bond model to describe the bonding in 1-propene, CH3-CH=CH2. a) Determine the hybridization of each carbon atom. b) List each sigma bond and the orbitals that overlap to form them. c) List each pi bond and the orbitals that overlap to form them. d) Draw the molecule showing the overlapping orbitals. Chemistry 51 2023-2024 Page 178 8. Circle and name the functional groups in each of the following organic molecules. NH2 O HO HS OH N H NH2 serotonin cysteine (an amino acid) OH CH2 O CH3 H3C H O CH3 HO N N H CH3 N O CH3 Stevia caffeine N H OH N H H Histrionicotoxin (poison frogs) Chemistry 51 2023-2024 Page 179 [This page intentionally blank] Chemistry 51 2023-2024 Page 180
0
You can add this document to your study collection(s)
Sign in Available only to authorized usersYou can add this document to your saved list
Sign in Available only to authorized users(For complaints, use another form )