I. Fundamental Concepts of Hazardous Locations Definition: An area is considered hazardous due to the presence of "highly flammable nature of a vapor, gas, dust, or solid material that may be easily ignited to cause fire or an explosion." (Source: Code Discussion) Classification Systems: Hazardous locations are categorized into Classes, Divisions, and Zones to define the type and degree of hazard. Classes: Class I: Flammable vapors or gas (e.g., gasoline, natural gas). Subdivided into Groups A, B, C, D (Article 501) or IIA, IIB, IIC (Article 505) based on ignition characteristics like Maximum Experimental Safe Gap (MESG) and Minimum Ignition Current (MIC) ratio. Class II: Combustible dust (e.g., grain dust). Subdivided into Groups E, F, G. Class III: Easily ignitable fibers or flyings (e.g., cotton, dry wood fibers). Divisions (Traditional System - Articles 500-503): Division 1: Hazardous material "is likely to be present" under normal operating conditions. Division 2: Hazardous material is present in dangerous quantities "only under accidental spills or other unusual circumstances." Zones (Alternate System - Articles 505 & 506): Class I (Vapors/Gases - Article 505):Zone 0: Ignitable concentration "is present continuously or is normally present for extended periods of time." Zone 1: Ignitable concentration "is likely to be present for limited periods of time during normal operation, system breakdown, or repair." Zone 2: Ignitable concentration "is not likely to exist during normal operation, and if an ignitable mixture becomes present, it will only exist for a short period of time." Class II/III (Dusts/Fibers/Flyings - Article 506):Zone 20: Combustible concentration exists "all of the time or for extended periods of time." Zone 21: Combustible accumulation or suspension "is likely to occur." Zone 22: Combustible accumulation is "not likely to occur, but is possible under unusual or accidental circumstances." (Source: Article 506) Expert Consultation: "It may be necessary to involve an expert, such as a registered professional engineer, with knowledge of the process and materials to decide the boundaries of the hazardous area, as well as to determine when a material constitutes a hazard." (Source: Code Discussion) II. Wiring Methods and Equipment in Hazardous Locations General Principle: "Achieving a safe and low-cost wiring system is the result of locating as much electrical equipment as possible out of the hazardous area." (Source: Hazardous Location Wiring Fundamentals) A. Class I Locations (Flammable Vapors/Gases) Division 1 Permitted Wiring Methods: Threaded Rigid Metal Conduit, threaded Intermediate Metal Conduit, and Type MI Cable. (Source: Article 501) Sealing Requirements (Explosion-proof Systems): Seals are critical to confine internal explosions within the wiring system. Conduit seals must be installed "within 18 in. (450 mm)" of an enclosure containing arc or heatproducing components. (Source: NEC® 501.15(A)(1)) Sealing compound thickness must be at least the trade size of the fitting, or 5/8 in. (16 mm), whichever is greater. (Source: NEC® 501.15(C)(3)) Standard sealing fittings are rated for only "25% fill" of conductor cross-sectional area, based on Rigid Metal Conduit area. (Source: Figure 9.8, Table 9.2) Explosion-Proof Enclosures: Designed to "withstand the pressure of the internal explosion" and prevent ignition of external vapors by cooling escaping gases. Require "at least five threads engaged" for all threaded joints to ensure slow cooling of escaping gases. (Source: NEC® 500.8(E) and 505.9(E)) Surface temperature must remain below the ignition temperature of the surrounding gas. Zone System (Article 505) - Protection Techniques: Intrinsic Safety (ia, ib): Equipment designed "such that even if a fault or a short circuit occurs, sufficient energy is not available to ignite the hazardous vapor, dust, or material." (Source: Code Discussion) Type 'ia' for Zone 0, 'ib' for Zone 1. Flameproof (d): Designed to "withstand an internal explosion without causing the ignition of the vapors surrounding the equipment." Permitted in Zone 1. Purged and Pressurized (p): Reduces ignition chance by ventilating air from an unclassified location. Permitted in Zone 1 and 2. Increased Safety (e): Characterized by "not producing any arcs or sparks under normal operating conditions," and measures to reduce surface temperatures. Permitted in Zone 1. Encapsulation (m, ma, mb): Arc-producing contacts encased in a compound. 'm' for Zone 1, 'ma' for Zone 0, 1, 2, 'mb' for Zone 1, 2. Powder-filled (q): Spark-producing contacts surrounded by filling powder. For Zone 1. Oil Immersion (o): Electrical equipment immersed in nonflammable liquid. For Zone 1. Type n (nA, nC, nR): Equipment designed "not capable of igniting a surrounding hazardous vapor." Permitted in Zone 2. B. Class II Locations (Combustible Dust) Principle: Prevent dust entry. "Gaskets will prevent the entry of dust particles." (Source: DustIgnitionproof Equipment) Enclosures: Not required to be as heavy as Class I; gaskets prevent dust entry. Sealing: Required to prevent dust entry, not necessarily to isolate internal combustion. C. Class III Locations (Flammable Fibers/Flyings) Principle: Prevent entry of fibers/flyings and ensure surface temperatures do not exceed ignition temperature even with material accumulation. Enclosures: Generally have "hinged doors with a latch and a gasket around the edges of openings." (Source: Flammable Fibers and Flyings) D. Intrinsically Safe Wiring Systems (Article 504) Any wiring method suitable for unclassified locations is permitted for intrinsically safe circuits in classified locations. Separation Requirements: Must be separated by a minimum of "2 in. (50 mm)" from power and light wiring systems if both are fixed in place, or by metal partitions/approved insulating barriers (2008 Code change). (Source: NEC® 504.30) Identification: Terminals must be identified to prevent accidental interconnection, and wiring must have "a permanent label affixed to the wiring at intervals with a minimum spacing of 25 ft (7.5 m)." The label reads "Intrinsic Safety Wiring." (Source: NEC® 504.80) Seals: Not required to be explosion-proof for intrinsically safe circuits as they cannot cause ignition. (2008 Code change - Source: Article 504, 504.70) III. Special Occupancies (Articles 510-516) These articles provide specific definitions of hazardous areas and wiring requirements for unique facilities. Commercial Garages (Article 511): Repair facilities for combustion motor equipment. Hazardous locations are defined (e.g., 18 inches above the floor in areas where gasoline vehicles are serviced). For vehicles using lighter-than-air fuels like CNG, the area 18 inches down from the ceiling is also Class I, Division 2. (Source: Figure 9.10, Article 511) Aircraft Hangars (Article 513): Hazardous areas cover larger portions due to aircraft height and fuel tanks. Raceways within or beneath hangar floors are considered Class I. For aircraft painting hangars, specific large hazardous zones are defined (e.g., 10 ft horizontally and vertically from the aircraft). (Source: Article 513) Gasoline Dispensing & Service Stations (Article 514):Space within the dispenser is Class I, Division 1. Area 20 ft (6m) horizontally from the dispenser and up to 18 in. (450 mm) above grade is Class I, Division 2. (Source: Figure 9.5) Conduits emerging from the ground beneath a Class I location must be sealed within 10 ft (3.05 m) of emergence, with no couplings/fittings between. Threaded Rigid Metal Conduit or IMC is required. Rigid Nonmetallic Conduit is permitted at least 2 ft (600 mm) below grade. (Source: Figure 9.11, NEC® 514.8) Bulk Storage Plants (Article 515): Hazardous areas defined around tanks and distribution points for flammable liquids. Spray Application, Dipping, and Coating Processes (Article 516): Boundaries defined for paint spray areas and dipping processes, considering vapor sources. IV. Grounding and Bonding Critical Importance: "Grounding is extremely important in hazardous locations." The grounding path must be "of low impedance" to prevent arcing during fault conditions. Wrench-Tight Connections: All threaded connections must be "wrenchtight" to prevent sparking at joints if the conduit carries fault current. Special Bonding: "Double locknuts are not permitted to serve as the equipment grounding for a circuit in a hazardous location." Direct bonding is required from conduit entries into enclosures, even if the enclosure is outside the hazardous area. (Source: Figure 9.9, NEC® 501.30(A), 502.30(A), 503.30(A), 505.25(A), 506.25(A)) V. Major Changes from 2005 to 2008 Code (Relevant to this Unit) Article 500:Combustible gas detection equipment now requires listing for Class I and appropriate Division, in addition to the specific gas. (Source: 500.7(K)) New section recommends criteria for judging equipment suitability, acknowledging some unlisted/unlabeled equipment may be suitable. (Source: 500.8(A)) Article 501:Schedule 80 PVC and RTRC with suffix -XW now permitted in some Class I, Division 2 locations for corrosion issues, limited to industrial locations with supervised qualified personnel. Seal must be on the Division 2 side. (Source: 501.10(B)(7), Figure 9.12) Article 502:Effective January 1, 2011, transformers, resistors, meters, instruments, and relays in Class II, Division 2 locations will require dusttight enclosures. (Source: 502.120(B)(2), 502.150(B)(1)) Article 504 (Intrinsically Safe Systems):New exceptions allow intrinsically safe circuits to share raceway/cable tray with non-intrinsically safe circuits in Division 2 or Zone 2 locations if separation rules are followed. (Source: 504.30(A)(1) Exception 2 & 3) Alternative methods for maintaining conductor separation within enclosures (metal partition, insulating barrier, shielded cable). (Source: 504.30(A)(2)) Associated apparatus must now be grounded. (Source: 504.50(B)) Seals for intrinsically safe circuits are not required to be explosion-proof but must be accessible and identified. (Source: 504.70) Article 505 (Class I, Zone Locations):Area classification, installation design, selection, installation, and inspection no longer require a Registered Professional Engineer, but a "qualified person." Local ordinances or facility owners may still require an engineer. (Source: 505.7(A)) New permitted protection types for Zone locations, including "ma" encapsulation (Zone 0, 1, 2) and "mb" encapsulation (Zone 1, 2). (Source: 505.8(H), 505.8(I)) Schedule 80 PVC and RTRC with suffix -XW now permitted in some Class I, Zone 2 locations. (Source: 505.15(C)(1)(g)) Flexible cord terminations at "e" (increased safety) enclosures must also be "e" rated. (Source: 505.17(6)) Article 506 (Zone 20, 21, 22 Locations):Several new definitions for protection types, including encapsulation "mD," enclosure "tD," intrinsic safety "iD," and pressurization "pD." (Source: 506.2) New rules for equipment markings for Zone 20, 21, 22. (Source: 506.9(C)(2), Figure 9.13) Article 511 (Commercial Garages):Added definitions for "major" vs. "minor" automotive repair facilities, impacting the extent of hazardous area classification. (Source: 511.2, 511.3) Article 513 (Aircraft Hangars):New definition for aircraft hangars used exclusively for painting. (Source: 513.2) New section defines classified hazardous area limits within aircraft painting hangars. (Source: 513.3(C)(2)) Note on Code References: The document consistently points to specific NEC® articles and sections for detailed rules and requirements, emphasizing that the provided analysis is a summary and not a replacement for the full Code.
0
You can add this document to your study collection(s)
Sign in Available only to authorized usersYou can add this document to your saved list
Sign in Available only to authorized users(For complaints, use another form )