Engineering Standard 16 August 2022 SAES-B-055 Plant Layout Document Responsibility: Loss Prevention Standards Committee Previous Revision: 28 October 2021 Contact: Ghamdi, Hatem S (GHAMHS0A) © Saudi Arabian Oil Company, 2022 Saudi Aramco: Company General Use Next Revision: 20 August 2027 Page 1 of 42 Document Responsibility: Loss Prevention Standards Committee SAES-B-055 Issue Date: 16 August 2022 Next Revision: 20 August 2027 Plant Layout Contents Summary Of Changes ................................................................................................... 3 1 Scope ...................................................................................................................... 8 2 Conflicts And Deviations ....................................................................................... 8 3 References .............................................................................................................. 8 4 Terminology............................................................................................................ 9 5. Design Considerations ........................................................................................ 11 6 Instructions For Use Of Spacing Charts And Tables ........................................ 12 7 Miscellaneous Onsite Spacing Requirements ................................................... 13 8 Miscellaneous Offsite Spacing Requirements................................................... 15 Appendix – Supplemental Information ...................................................................... 20 FIGURE 1 - ONSITE SPACING CHART .............................................................................. 40 FIGURE 2 - OFFSITE SPACING CHART ............................................................................ 41 Document History ....................................................................................................... 42 © Saudi Arabian Oil Company, 2022 Saudi Aramco: Company General Use Page 2 of 42 Document Responsibility: Loss Prevention Standards Committee SAES-B-055 Issue Date: 16 August 2022 Next Revision: 20 August 2027 Plant Layout Summary of Changes Paragraph Number Previous Revision Change Type Technical Change(s) Current Revision (Addition, Modification, Deletion, New) (28 October 2021) (16 August 2022) 3.1 3.1 Addition References to SAEP-13, SAES-A-112 and SAES-J-510 added. 3.1 3.1 Deletion Reference SAES-J-502 deleted as it has been cancelled. 3.1 3.1 Deletion Reference AB-036667 deleted as it has been cancelled. 3.1 3.1 Addition Reference to Library Drawing DB-950439-001 added as drawing AB-036667 has been converted to a library drawing. 3.1 3.1 Modification The titles of the following SAESs have been updated: SAES-B-009, SAES-B-060 and SAES-B-070 3.1 3.1 Addition Reference to SAES-B-801 added. 4 4.1 Modification For consistency the definitions of Flammable and Combustible Liquids now refer to the equivalent definitions in SAES-B-005. 4 4 Deletion The definition of Flashing Liquid has been removed as it is not required in this document. 4 4.1 Modification The definition of Main Office Buildings has been simplified to remove any subjectivity and stress that it is the population of the building that is important. 7.4.2 7.4.2 Modification Reference to Analyzer Shelters changed from SAESJ-502 to SAES-J-510 as the previous reference no longer exists. © Saudi Arabian Oil Company, 2022 Saudi Aramco: Company General Use Page 3 of 42 Document Responsibility: Loss Prevention Standards Committee SAES-B-055 Issue Date: 16 August 2022 Next Revision: 20 August 2027 N/A Plant Layout 7.7.1 Addition Statement added ‘Portable gas cylinders in plant areas shall comply with the requirements of SAES-B-801, Chapters 53 and 58, and the Construction Safety Manual’. This ensures compliance with the relevant requirements of the above-mentioned documents. 8.1 8.1 Deletion The following sentence has been deleted as section 5.5 was removed in the 2017 revision of the document to ensure that approval of technical deviations is in compliance with SAEP-302: ‘The provisions of Section 5.5 shall apply if reductions are needed’. 9.5.1 8.6.1 Modification Last sentence modified to ‘The plan shall be reviewed by the Proponent, Area Loss Prevention and Fire Protection Departments’. This ensures that the layout and spacing of roads is also reviewed by the fire protection department. N/A 8.6.10 (a) Addition The following statement has been added ‘Roadways shall be designed in compliance with SAES-B-801, Chapter 5’. This ensures roads are designed to facilitate the safe access and maneuvering of fire trucks. © Saudi Arabian Oil Company, 2022 Saudi Aramco: Company General Use Page 4 of 42 Document Responsibility: Loss Prevention Standards Committee SAES-B-055 Issue Date: 16 August 2022 Next Revision: 20 August 2027 N/A Plant Layout 8.6.10 (h) Addition The following statement has been added ‘Primary and secondary roads shall not be routed through electrically classified areas’. This ensures that vehicles, using primary or secondary roads, do not pass through electrically classified areas. This ensures that only accessways, which are barriered off, are allowed within electrically classified areas and vehicles 9.5.3 8.6.3 Modification Reference to AB-036667 has been replaced with DB950439-001 as this is now a library drawing. 9.6 9.6 Deletion Paragraph 9.6 deleted and wording added to Appendix X2. Appendix A-1 Appendix A-1 Deletion Reference to E-1 removed to align with Figure 1. Appendix P-2 Appendix P-2 Modification Statement added: ‘Other security related spacing requirements may apply, refer to SAES-O-202’. This ensures that security related requirements with respect to property lines are considered in the spacing of facilities. Appendix S-2 Appendix S-2 Addition Statement added to state the required minimum spacing between office buildings and flares. Appendix: U-2 Appendix: U-2 Deletion Reference to D-2 removed to align with Figure 2. © Saudi Arabian Oil Company, 2022 Saudi Aramco: Company General Use Page 5 of 42 Document Responsibility: Loss Prevention Standards Committee SAES-B-055 Issue Date: 16 August 2022 Next Revision: 20 August 2027 Appendix: V-2 Plant Layout Appendix: V-2 Modification Residential Area requirements moved from existing Appendix V-2 to a new Appendix X-2 since the spacing requirements differ from main office buildings. This is because residential areas are considered extremely vulnerable as they are densely populated and difficult to evacuate during emergencies as residents often include children, elderly and people with special needs. Also, further clarification added to enable main office buildings to be located closer to plant perimeter fences if supported by a BRA study and cost-effective measures. Appendix X-2 Appendix X-2 New Incorporates requirements from paragraph 9.6 which has been deleted. QRA and environmental impact assessment (EIA) per SAEP-13 shall be conducted to determine the required spacing. In no case shall residential areas be located closer than 500 m from the perimeter fence of any hydrocarbon facility. The requirement to develop LSIRs for all new facilities to quantify the land use development within the vicinity of Saudi Aramco hydrocarbon facilities is also emphasized. Figure 1: Figure 1: A-1 to T-1 & A-1 to T-1 & T-1 to A-1 T-1 to A-1 Modification © Saudi Arabian Oil Company, 2022 Saudi Aramco: Company General Use Spacing increased to 30m to align with the existing requirement in Appendix: A-1. Page 6 of 42 Document Responsibility: Loss Prevention Standards Committee SAES-B-055 Issue Date: 16 August 2022 Next Revision: 20 August 2027 Plant Layout Figure 1: Figure 1: Spacing Between Control Buildings (A1), Satellite Instrument Buildings (B-1) and Plant Electrical Load Centers or Substations (C-1) Spacing Between Control Buildings (A1), Satellite Instrument Buildings (B-1) and Plant Electrical Load Centers or Substations (C-1) Figure 2: Figure 2: O-2 to Q-2 O-2 to Q-2 Figure 2: Figure 2: Spacing Between Spacing Between E-2 to E-2 E-2 to E-2 E-2 to N-2 E-2 to N-2 K-2 to K-2 K-2 to K-2 K-2 to V-2 K-2 to V-2 N-2 to N-2 N-2 to N-2 N-2 to V-2 N-2 to V-2 Figure 2 Figure 2 Row V-2 Row V-2 Figure 2 Figure 2 Row X-2 Row X-2 Modification Spacing changed from A to E: i.e. ‘Provide separation between buildings based on access for operation, maintenance and firefighting and Saudi Aramco Building Code (SAES-M-100) requirements for fire separation distance; whichever is greater’. Modification Spacing changed from 1.5m to 15m as this was a typo. Modification Spacing changed from X to T: i.e. ‘Provide separation between buildings based on access for operation, maintenance and firefighting and Saudi Aramco Building Code (SAES-M-100) requirements for fire separation distance; whichever is greater’. Modification Residential areas moved to new row X-2 and certain spacing requirement for Main Office Buildings updated. New © Saudi Arabian Oil Company, 2022 Saudi Aramco: Company General Use New Row X-2 added for Residential Areas. Page 7 of 42 Document Responsibility: Loss Prevention Standards Committee SAES-B-055 Issue Date: 16 August 2022 Next Revision: 20 August 2027 1 Plant Layout Scope This standard provides minimum spacing requirements for equipment and structures in the design and layout of new plants and expansions or modifications of existing plants. Exception: Where this standard is in conflict with specialized requirements for offshore platforms, covered in SAES-B-009; for piers, wharves, sea islands, in SAES-B060; bulk plants/air fueling operations in SAES-B-070, and buildings in SAES-M100, those standards shall govern. 2 Conflicts and Deviations Any conflicts between this document and other applicable Mandatory Saudi Aramco Engineering Requirements (MSAERs) shall be addressed to the EK&RD Coordinator. Any deviation from the requirements herein shall follow internal company procedure SAEP-302. 3 References All referenced specifications, standards, codes, drawings, and similar material are considered part of this engineering standard to the extent specified, applying the latest version, unless otherwise stated. 3.1 Saudi Aramco References Saudi Aramco Engineering Procedures SAEP-13 SAEP-302 Project Environmental Impact Assessments Waiver of a Mandatory Saudi Aramco Engineering Requirement Saudi Aramco Engineering Standards SAES-A-112 SAES-B-005 SAES-B-006 SAES-B-009 SAES-B-014 SAES-B-060 SAES-B-062 Meteorological and Seismic Design Data Spacing and Diking for Atmospheric and Low-Pressure Tanks Fireproofing for Plants Fire/Blast Protection and Safety Requirement for Offshore Production Facilities Safety Requirements for Plant and Operations Support Buildings Fire Protection and Safety Requirements for Piers, Wharves, and Sea Islands Onshore Wellsite Safety © Saudi Arabian Oil Company, 2022 Saudi Aramco: Company General Use Page 8 of 42 Document Responsibility: Loss Prevention Standards Committee SAES-B-055 Issue Date: 16 August 2022 Next Revision: 20 August 2027 SAES-B-064 SAES-B-068 SAES-B-069 SAES-B-070 SAES-B-801 SAES-D-109 SAES-D-110 SAES-F-007 SAES-J-510 SAES-L-310 SAES-O-202 SAES-P-107 SAES-S-020 SAES-X-700 Plant Layout Onshore and Nearshore Pipeline Safety Electrical Area Classification Emergency Eyewashes and Showers Fire and Safety Requirements for Bulk Plants, Air Fueling Terminals, and Sulfur Loading/Unloading Facilities Saudi Aramco Fire Code Design of Small Metallic Storage Tanks Design of Fiberglass-Reinforced Plastic (FRP) Storage Tanks System Design Criteria of Flares Process Analyzer Systems Design of Plant Piping Security Fencing Systems Overhead Distribution Systems Oily Water Drainage Systems Cathodic Protection of Onshore Well Casings Saudi Aramco Manuals SACSM Saudi Aramco Construction Safety Manual Saudi Aramco Library Drawing DB-950439-001 4 Terminology 4.1 Definitions Tell - Tales for Overhead Powerline and Pipeway Crossings - Details Accessway: An accessway is a level paved area that allows access for mobile maintenance or firefighting vehicles to equipment. An accessway will often have a dead-end since it is not intended for continued travel through a unit. Accessways are restricted to use only by emergency vehicles, for maintenance, or for the delivery of operations or maintenance supplies. Basic Spacing: Basic spacing is the minimum required distance to be maintained between a certain type of equipment and other equipment, buildings, or support facilities unless otherwise indicated in the body of the chart. Combustible Liquid: Refer to SAES-B-005. Flammable Liquid: Refer to SAES-B-005. High-Flash Stocks: High-flash Stocks are fluids having a flash point over 54°C (130°F), stored at temperatures more than 8°C below the flash point. Also see Combustible Liquid. © Saudi Arabian Oil Company, 2022 Saudi Aramco: Company General Use Page 9 of 42 Document Responsibility: Loss Prevention Standards Committee SAES-B-055 Issue Date: 16 August 2022 Next Revision: 20 August 2027 Plant Layout Low-flash Stocks: Low-flash stocks are fluids with a true vapor pressure less than 90 kPa(abs) (13 psia) and a flash point under 54°C (130°F). This may also characterize any other fluids that are stored at temperatures above the fluids flash point or within 8°C of the fluid's flash point. Main Overhead Powerlines: Powerlines that carry a power load in excess of 69 kV. Main Office Building: For the purpose of this standard, a main office building is a building that contains offices for 25 or more people. Major Highway: A major highway (for the purposes of use in Section 8.5 in this standard) is a public primary or secondary roadway as designated by the Ministry of Transport. A primary road connects urban areas of 100,000 persons or more, connects multiple regions, and serves international connections and is generally a limited access highway. A secondary road may or may not have controlledaccess, connects urban areas of 50,000 persons or more, connects 2 regions, and may or may not serve international connections. Major Offsite Pipeways: Piping that interconnects plants or that connects plants and storage facilities. Off-site Spacing: Spacing between units. Also spacing between a unit and certain types of equipment that are not normally inside a process unit such as flares or LPG storage vessels. On-site Spacing: Spacing between equipment within the same process unit or utility unit. Perimeter Fence: The fence which completely surrounds an area designated by Saudi Aramco for a distinct function (plant area, light industrial part, camp, or other function). Plant Area: The designated area engaged in the production, processing, manufacturing, storage, and transportation of crude oil, natural gas, refined products and their derivatives. A plant area may be inside an onshore perimeter fence or on the decks of offshore structures. Plant Piping: Pressure piping system, within an identified plant-area. Plant piping design and spacing is covered in SAES-L-310. Plant Utility Service: The supply of steam, water, air, nitrogen, or inert gas within a processing plant. Plot-Limit: The plot-limit is a boundary, within the plant area, which surrounds a single unit or function. The plot-limit may be physical such as a wall, the edge of a road or pipe-way, chains, posts, or a boundary indicated on an approved plot plan. © Saudi Arabian Oil Company, 2022 Saudi Aramco: Company General Use Page 10 of 42 Document Responsibility: Loss Prevention Standards Committee SAES-B-055 Issue Date: 16 August 2022 Next Revision: 20 August 2027 Plant Layout RTR Pipe: Glass-fiber-reinforced thermosetting resin pipe, also called RTRP or fiberglass pipe. Satellite Instrument House or Building: Otherwise known as a PIB (Process Interface Building) or I/O rack room (I/O refers to input/output, or sending and receiving of data). This is a building that houses essential electronics equipment for controlling and monitoring of field equipment. Tell-Tale: A horizontal cable or post across a road right-of-way at the maximum allowable elevation to cross safely under a powerline, pipe rack or other obstruction. 5. Design Considerations 5.1 General 5.2 5.1.1 Plant layouts for new construction shall provide for a maximum of safety and exposure protection from the spread of fire, with ease of operation and maintenance consistent with economical design. 5.1.2 Requirements for future expansion shall be identified by the Facilities Planning Department and reasonable allowances made on the plot plan drawings. Basic Objectives The basic objectives of the Spacing Design criteria given in this standard are as follows: 5.2.1 To minimize involvement of adjacent facilities in a fire. 5.2.2 To permit access for firefighting. 5.2.3 To ensure that critical emergency facilities will be accessible for operators to perform emergency shutdown actions in the event of a fire or explosion. 5.2.4 To segregate higher-risk facilities or equipment from less hazardous operations and equipment. 5.2.5 To separate continuous ignition sources from equipment that may have a higher potential to be a source of release of flammable materials. 5.2.6 To permit access by plant personnel for normal operation and maintenance of equipment. 5.2.7 To avoid danger or nuisance to persons or facilities beyond the adjacent property lines. 5.2.8 To minimize equipment damage from a fire or explosion to the immediate area. © Saudi Arabian Oil Company, 2022 Saudi Aramco: Company General Use Page 11 of 42 Document Responsibility: Loss Prevention Standards Committee SAES-B-055 Issue Date: 16 August 2022 Next Revision: 20 August 2027 5.3 Plant Layout Spacing Basis The minimum required spacing distances given in this standard will provide spacing similar to other plants when compared with facilities similar in nature elsewhere in the world. They are minimums which will satisfy the above objectives but do not account for situations such as potential vapor cloud explosions or flare stack dispersion. There will be instances when special considerations will provide cause to deviate from these recommended spacing. 6 Instructions for Use of Spacing Charts and Tables 6.1 Spacing Distances The required minimum spacing distances for buildings and equipment are presented in the Onsite Spacing Chart (Figure 1) and the Offsite Spacing Chart (Figure 2). 6.2 Spacing Charts - Basic Spacing For each facility covered in the charts, the basic spacing is given. This basic spacing is the required distance to be maintained between a given facility and other general processing equipment, building or support facility unless a deviation is indicated in the body of the chart. (See paragraph 6.3 for spacing between two facilities). This distance is required to minimize the likelihood of a specific facility becoming involved in fires originating on other equipment, or vice versa. This basic spacing is not normally required between items of equipment in similar services, such as a pump and its spare, or pumps and compressors and their individual drivers. 6.3 Spacing between Two Facilities The spacing requirement between two facilities is obtained from Figure 1 or Figure 2 at the inter-section of the appropriate horizontal rows and vertical columns. 6.4 Reference to Spacing Guides in the Appendix It is essential that the onsite and offsite charts be used in conjunction with the spacing guides provided in the Appendix of this standard. These guides are intended to supplement their respective charts with the following information: 6.4.1 Explanation of the basic spacing requirements for each facility -Normally, spacing between facilities will be the larger of the two basic spacing involved. 6.4.2 Explanation of variations from the basic spacing requirements -These explanations are given in the guide for only one of the two facilities involved. Therefore, reference shall be made to the write-up for both categories to obtain the reasoning for basic spacing variations. © Saudi Arabian Oil Company, 2022 Saudi Aramco: Company General Use Page 12 of 42 Document Responsibility: Loss Prevention Standards Committee SAES-B-055 Issue Date: 16 August 2022 Next Revision: 20 August 2027 6.4.3 6.5 Plant Layout General remarks on location and spacing for each facility. Special Equipment Gas expansion turbines and hydraulic turbines shall be treated in their spacing similar to compressor or pumps handling flammable fluids. 7 Miscellaneous Onsite Spacing Requirements 7.1 Introduction to Onsite Spacing Chart – Figure 1 The onsite Spacing Chart in Figure 1 provides spacing distances for the typical on-site equipment. However, it is impractical to include all spacing requirements in Figure 1. For this reason, spacing is established in this section for additional items of equipment where fire prevention or safety spacing is considered to be important. This includes personnel safety items, as well as equipment involved in hydrocarbon releases or providing a source of ignition for such releases. 7.2 Air Intake Locations Air intakes are required for a number of items of equipment that are located in or near plants. Included are internal combustion engines and turbines, air compressors, inert gas generators, forced draft furnaces, buildings (including substations) containing unclassified electrical equipment, and boilers. These equipment items represent an internal source of ignition for any flammable vapors that might have been pulled in with the air, and the potential for internal explosion. For this reason, the locations of air intakes in relation to adjacent equipment must be carefully selected. Factors to be taken into account include prevailing wind direction, probable horizontal and vertical dispersion patterns, and the degree of hazard that would result from contamination of the air and possible formation of a flammable vapor/air mixture. In instances where air conditioning equipment is utilized for buildings in hydrocarbon processing plants, additional factors for protection of personnel hazards or nuisance from toxic or other vapors shall meet SAES-B014. 7.3 Facility layout and spacing for offshore GOSPs shall meet SAES-B-009. 7.4 Analyzer and Operator Shelters 7.4.1 Analyzer and Operator shelters may be located within the plot-limits of a plant. 7.4.2 The shelters shall be located with free access of no less than 3 m on all sides. For details, see SAES-B-014 and SAES-J-510. © Saudi Arabian Oil Company, 2022 Saudi Aramco: Company General Use Page 13 of 42 Document Responsibility: Loss Prevention Standards Committee SAES-B-055 Issue Date: 16 August 2022 Next Revision: 20 August 2027 7.5 7.6 Plant Layout Exhaust stacks 7.5.1 Atmospheric exhausts from steam turbines, combustion gas turbines, and internal combustion engines shall be located so that they will not present a hazard to personnel and/or equipment on the same platform or on adjacent working platforms. They shall be at least 3 m higher than any platform or access within a horizontal distance of 7.5 m. 7.5.2 The exhaust stack for combustion gas turbines and internal combustion engines shall discharge above the turbine or engine at a level outside the classified electrical area. 7.5.3 Where the turbine or engine is driving a compressor or pump handling flammable fluid, the pump area shall not be enclosed and shall be freely ventilated, and the stack shall be covered by insulation and an outer jacketing impervious to liquids. Emergency Eyewashes and Showers For locations of emergency eyewashes and showers, refer to SAES-B-069. 7.7 Portable Gas Cylinders Portable gas cylinders are used in some plant areas. Vulnerability to fire exposure shall be considered in selecting their location within the plant. The following shall apply: 7.7.1 Portable gas cylinders in plant areas shall comply with the requirements of SAES-B-801, Chapters 53 and 58, and the Construction Safety Manual. 7.7.2 High-risk cylinder installations involving multiple cylinders of flammable or toxic fluids shall be located at the edge of the plant area, and no less than 15 m from other hydrocarbon equipment. Good access for firefighting shall be provided. Bulk storage of such cylinders shall be located in a remote offsite area. 7.7.3 Lower-risk installations of single cylinders containing flammable material or multiple cylinders of inert gases shall be located at least 7.5 m from high fire risk equipment such as pumps, gas compressors, furnaces, and equipment operating over 315°C. In all instances, cylinders must be adequately chained or supported to avoid the possibility of falling or being knocked over. 7.8 Cathodic protection equipment spacing shall meet the requirements of SAES-X-700. 7.9 Windsocks shall be installed at plant facilities handling flammable gases, volatile liquids, or toxic materials. These areas include, but are not limited to, GOSPs, gas processing and compression plants, chlorination facilities, bulk plants, © Saudi Arabian Oil Company, 2022 Saudi Aramco: Company General Use Page 14 of 42 Document Responsibility: Loss Prevention Standards Committee SAES-B-055 Issue Date: 16 August 2022 Next Revision: 20 August 2027 Plant Layout production or injection wellsites in populated areas, permanent outdoor storage areas for portable gas cylinders, and near gas flare systems. Windsocks shall be mounted where they can be clearly seen from most ground level points within the plant boundary. Mounting shall be on the tops of structures or on a pole. More than one windsock may be required at a plant site. Windsocks shall also be installed at heliports. Windsocks at heliports shall be lighted if required for night flights by the Chief Pilot. Windsocks are not required along pipelines except in hydrocarbon pump stations and major manifolding and scraping stations. 7.10 For plant piping spacing requirements, see SAES-L-310. 7.11 Use of vegetation for landscaping is prohibited within a plant area. 8 Miscellaneous Offsite Spacing Requirements 8.1 Introduction to Offsite Spacing Chart – Figure 2 8.2 8.1.1 The Offsite Chart in Figure 2 provides spacing distances for the typical facilities being used by Saudi Aramco. These recommended figures will satisfy the objectives listed in Section 5.2. 8.1.2 Since it is impractical to include all offsite spacing requirements in Figure 2, additional spacing for miscellaneous facilities are included in Section 8. The Appendix shall also be used in conjunction with this chart as outlined in 6.4. GOSP, Bulk Plant, and Storage Facilities All facilities within the plot-limits shall be located a minimum of 300 meters from major roadways or railroad lines. 8.3 Marine Loading Facilities There are no basic spacing guidelines of onshore or offshore tanker loading facilities. The spacing will be dictated by operational and sailing requirements of the tankers being loaded. Fire prevention and safety requirements are covered in SAES-B-060. 8.4 Offshore Platforms Spacing for the auxiliary platforms associated directly with a GOSP is covered under SAES-B-009. Other offshore platforms are normally unmanned and support no process, separating or storage facilities. Examples are water injection platforms and platforms supporting piping manifolds only. Such platforms shall normally be placed at least 45 m from any platform containing oil and gas separation, processing, handling or storage facilities. © Saudi Arabian Oil Company, 2022 Saudi Aramco: Company General Use Page 15 of 42 Document Responsibility: Loss Prevention Standards Committee SAES-B-055 Issue Date: 16 August 2022 Next Revision: 20 August 2027 8.5 Plant Layout Electrical Grid Transmission Lines Spacing between overhead electrical grid transmission lines and pipelines shall be in accordance with SAES-B-064. The following minimum basic spacing for electric transmission lines shall be kept from: 8.6 a) Flares and burn pits - 150 m horizontal. b) Major highways (as defined in Section 4) - 30 m horizontal. c) All items - 9 m vertical. Roadways in Plants and Other Facilities 8.6.1 The layout and spacing of roads is of considerable importance in a refinery or other major plants. They provide a means of access for normal maintenance equipment and firefighting equipment. A logistics study shall be done to prepare a roadway plan. The plan shall be reviewed by the Proponent, Area Loss Prevention and Fire Protection Departments. 8.6.2 All buildings, major equipment areas, and areas reserved for future plant expansions shall be accessible to allow for installation of large vessels or oversized heavy equipment. 8.6.3 The number of pipe racks and overhead powerlines crossing roads shall be minimized as much as possible in the layout of a plant area. Overhead obstruction warning signs and tell-tales shall be installed on each approach to pipe racks and powerlines. Refer to Saudi Aramco Library Drawing DB-950439-001 for installation details. 8.6.4 Vehicle barriers shall be provided for exposed piping near grade for primary and secondary roads. 8.6.5 Placement and protection of fire hydrants and monitors shall be such that firefighter access to the fire hydrant and monitor is not hindered. 8.6.6 When considering where to locate vehicle access for a plant, consideration shall be given to where surface drainage or gas leaks might prevent plant access for emergency responders during an incident. 8.6.7 The minimum vertical clearance (measured from the highest point of the road grade) of overhead powerline conductors at in-plant road crossings shall meet SAES-P-107. 8.6.8 Three types of roads are normally associated with oil processing plants, refineries, and similar facilities. © Saudi Arabian Oil Company, 2022 Saudi Aramco: Company General Use Page 16 of 42 Document Responsibility: Loss Prevention Standards Committee SAES-B-055 Issue Date: 16 August 2022 Next Revision: 20 August 2027 8.6.9 Plant Layout a) Primary roads are generally for vehicular traffic outside a plant but they may also be used inside large plants such as Ras Tanura Refinery. Primary roads are used to allow unrestricted traffic to travel more easily and safely between plants or through an industrial area such as a light industrial park. b) Secondary roads are roads which are inside the plant and normally carry general traffic with no restrictions. c) Accessways are usually within the plant plot-limits and restricted to maintenance or emergency vehicles or to the delivery of operational supplies after permission is secured from the plant operator. Accessways are normally posted and access physically restricted with an appropriate barrier, such as a gate or posts and chains, to prevent unauthorized access. The location and type of barriers needed will be assessed and included as part of the roadway plan approval. Vertical Clearance for Roads a) Vertical unrestricted clearance for elevated pipe racks and other obstructions crossing over primary and secondary roads shall be no less than 7.5 m. b) Vertical unrestricted clearance for elevated pipe racks and other obstructions crossing over accessways shall be no less than 5.5 m. Exception: Vertical clearance for overhead obstructions shall be no less than 5.5 m for roads and accessways for GOSPs and bulk plants. 8.6.10 The following requirements shall be followed in laying out roadways: a) Roadways shall be designed in compliance with SAES-B801, Chapter 5. b) Primary roads shall be 8 m wide, with 2 m shoulders on each side. Secondary roads shall be 7 m wide, with 1.5 m shoulders on each side. For primary and secondary roads the following clear spaces from the edge of the shoulder shall be maintained: No less than 5 m horizontal from the edge of the road shoulder to the nearest edge of buildings, pipeways, or equipment, with barriers placed between road and the building, pipeline, or equipment. © Saudi Arabian Oil Company, 2022 Saudi Aramco: Company General Use Page 17 of 42 Document Responsibility: Loss Prevention Standards Committee SAES-B-055 Issue Date: 16 August 2022 Next Revision: 20 August 2027 Plant Layout No less than 15 m horizontal from the edge of the road shoulder to the nearest edge of high-risk equipment such as pumps handling flammable materials, compressors handling flammable gases, equipment operating at over 315°C, and furnaces. 8.7 c) Accessways shall be a minimum of 6 m wide with a minimum spacing of 6 m horizontal from the accessway edge to the nearest edge of equipment or the related equipment skid. Refer to A1.2.3 for further details. d) Onshore plants shall be provided with at least a secondary access road on opposite sides of the plant. e) A primary access road to a plant shall not be located in a plant's surface drainage pattern, and shall be located on the plant's upwind side if practical. f) Normal vehicle traffic to the parking lot of plant facilities and to primary access gates shall not pass under power lines where practical. g) Primary and secondary roads shall not be routed through electrically classified areas. h) Primary and secondary roads shall not be routed through electrically classified areas. i) For roadways in tank farms, refer to SAES-B-005. j) For roadways in wellsite areas, refer to SAES-B-062. Restrictions on the Use of Nonmetal Tanks and Vessels 8.7.1 The use of tanks and vessels made of thermoplastic resins is prohibited. 8.7.2 Tanks and vessels made of fiberglass-reinforced plastic (FRP) or fiberglass composite may in some services be a technically acceptable alternative to steel and may be used subject to the following constraints: a) Small tanks or vessels shall meet SAES-D-109 or SAES-D110. b) All FRP vessels and tanks shall be located a minimum distance of 30 m from any hydrocarbon process piping or equipment. Consideration shall also be made to ensure that these tanks/vessels and any associated loading equipment or tank trucks, will not pose a hazard to other facilities. © Saudi Arabian Oil Company, 2022 Saudi Aramco: Company General Use Page 18 of 42 Document Responsibility: Loss Prevention Standards Committee SAES-B-055 Issue Date: 16 August 2022 Next Revision: 20 August 2027 Plant Layout c) Firefighting equipment and emergency procedures that are consistent with the type of chemical being stored or processed shall be provided at each installation. d) 100% diking of each nonmetal tank or vessel shall be provided. e) Drainage of any diked area shall be provided to meet SAESS-020. © Saudi Arabian Oil Company, 2022 Saudi Aramco: Company General Use Page 19 of 42 Document Responsibility: Loss Prevention Standards Committee SAES-B-055 Issue Date: 16 August 2022 Next Revision: 20 August 2027 Plant Layout Appendix – Supplemental Information A1.1 Scope The appendix provides supplemental information to be used in conjunction with the spacing given in Figure 1 and Figure 2 of this standard. A1.2 General Onsite Layout A1.2.1 Facilities Location Guidelines: Within plant plot limits, the locations of major facilities such as control houses, furnaces, compressors, electrical substations, etc., shall be determined in accordance with the spacing standards, with consideration given to proximity of adjoining facilities, location of roadways, prevailing wind direction, site topography, and similar factors. A1.2.2 Accessways in Layout-General: The overall layout of the process area shall be designed with accessways for firefighting, maintenance, and turnaround isolation. The typical rectangular block pattern is recommended for large plants and major complexes. This block layout will provide for at least two approaches to all major process units. Allweather roads shall be provided in all instances. A1.2.3 Accessways in Layout - Specific widths: The following guidelines shall be observed in overall plant layouts: A1.2.4 A1.2.3.1 Accessways shall be a minimum edge distance of 6 m to equipment. These preferably shall be arranged in rectangular patterns such that the shorter dimension of each subdivision area does not exceed 30 m. This layout arrangement will permit effective firefighting access for attack from two opposite sides, with at least one side expected to be available even under emergency conditions. Consideration shall also be given to limiting the longer dimension of each continuous equipment area to 60 m by the inclusion of additional firefighting accessways. A1.2.3.2 Provide 5.5 m clear space under overhead pipeways, with or without air-cooled heat exchangers above them, if this area is to be considered as firefighting access from one side of an area subdivision. Equipment Stacking: Some equipment stacking may be necessary to effectively utilize the plot space, but extensive stacking creates the potential of heavy fire involvement. Thus, the following restrictions on this practice shall apply: A1.2.4.1 Avoid stacking more than three levels of equipment in height. Generally, equipment stacked shall be in the same © Saudi Arabian Oil Company, 2022 Saudi Aramco: Company General Use Page 20 of 42 Document Responsibility: Loss Prevention Standards Committee SAES-B-055 Issue Date: 16 August 2022 Next Revision: 20 August 2027 Plant Layout service in the normal process flow path (i.e., column overhead condensers and accumulators). A1.2.4.2 Other equipment shall not be installed directly over any of the following: a) Pumps or compressors handling flammable materials. b) Air-cooled heat exchangers. c) Heat exchangers or drums containing flammable materials at temperatures above 315°C, or above the known auto ignition temperatures, if lower. A1.3 Onsite Spacing - Guide to Figure 1 Commentary Note: The notation “From A-1, B-1”, etc., found in the spacing discussions of various items, refers to the spacing between the equipment with those reference letters in Figure 1 and the particular item being discussed. A-1 Control Buildings General: Location shall be separated from any facilities creating an explosion risk and shall be directly accessible by a roadway. Spacing Distance, m. Basic 30 Blast Resistant 35 From T-1 B-1 30 Remarks Spacing is required to avoid fire involvement Blast resistant construction may be required. Refer to SAES-B-014. Pipeways closer than 30 m from central control houses shall be avoided. This spacing may be reduced on one side of the control building only to 15 m minimum, if the lines are all welded and flanges and valves are minimized. Satellite Instrument Buildings General: Location shall be at unit plot-limits, accessible by roadway. Spacing Basic Distance, m. 15 Remarks Spacing is provided to avoid fire involvement. It also provides a limited degree of protection from explosion. Any explosion significantly damaging the satellite instrument building would also involve associated plant equipment; thus, loss of the satellite instrument building would not in itself cause prolonged downtime of the associated plants. Reduced spacing may be allowed for low risk plants handling high-flash stocks at temperatures below their flash points. The electrical area classifications outlined in SAES-B-068 shall also be given consideration as they relate to spacing. To avoid need for special pressurization or classified electrical equipment, locate the building outside electrically © Saudi Arabian Oil Company, 2022 Saudi Aramco: Company General Use Page 21 of 42 Document Responsibility: Loss Prevention Standards Committee SAES-B-055 Issue Date: 16 August 2022 Next Revision: 20 August 2027 From E-1, T-1 C-1 D-1 E-1 Plant Layout 5 classified areas. Satellite instrument buildings may be closer to pipeways than to general process equipment, provided that the lines are all welded, and flanges and valves are minimized. Plant Main Electrical Load Centers or Substations Spacing Basic Distance, m. 15 From T-1 5 Remarks This spacing helps protect electrical equipment from fires or explosions in the plant equipment it is meant to serve. These facilities shall be located outside any fire hazardous zones per SAES-B-006 and electrically classified areas per SAES-B-068. Refer to SAES-B-014 for additional location requirements. Pipeways can be located closer if they do not contain flanges or valves. Electrical Switchracks Critical to Emergency Shutdown Systems Spacing Basic Distance, m. 7.5 From F-1 15 Remarks To avoid damage in a moderate fire, as it has relatively little resistance to fire exposure. The area classification requirements of SAES-B-068 shall also be met by this equipment. Due to the possibility of more severe fires in furnaces where split tubes can occur, additional space is provided to minimize damage to switch equipment. Emergency Valves for Isolation, Water Sprays, Shut Off, Snuffing Steam, etc. General: Spacing for valves or controls that need to be accessed during emergencies. F-1 Spacing Basic Distance, m. 15 From U-1 25 Remarks Provides access to critical valves or controls during emergency situations. Water spray valves provided for pressure storage vessels require additional spacing because of the higher risk associated with pressure storage. Furnaces, Heaters, and Boilers General: Furnaces, heaters and boilers present a constant source of ignition to any hydrocarbon release; therefore, their location must be carefully selected. The required location is on the upwind or crosswind side of a unit, near the plot-limits. Consideration shall be given to adjacent equipment which is potentially hazardous, whether in the same or a nearby unit. The top of the furnace stack shall be at least 3 m higher than any working platform within 60 m horizontally. © Saudi Arabian Oil Company, 2022 Saudi Aramco: Company General Use Page 22 of 42 Document Responsibility: Loss Prevention Standards Committee SAES-B-055 Issue Date: 16 August 2022 Next Revision: 20 August 2027 Plant Layout Spacing Basic Distance, m. 15 From D-1, 7.5 Remarks This spacing separates a constant source of ignition from equipment handling flammable materials. It also provides for reasonable access to emergency valves in case of a furnace split tube. Spacing will minimize damage to equipment in case of As a furnace fire or explosion. Reduced spacing provided since there can be no flammable material releases from D-1, and the materials handled by G-1 and I-1 are already above their autoignition temperatures so that furnaces do not represent the primary source of ignition. If all furnaces shut down together for test and inspection, G-1, I-1 From F-1 Required G-1 From H-1, V-1 25 From M-1 15 From T-1 7.5 From W-1 5 only normal maintenance spacing is required. Furnaces, which are shut down individually, require 7.5 m spacing if low pressure [less than 690 kPa(ga) operating pressure at coil inlet] and 15 m spacing if pressure is above 690 kPa(ga) at the coil inlet. Greater spacing is required due to potential for large vapor releases. As an exception, fuel gas knockout drums may be spaced as close as 7.5 m to their respective furnaces, but outside any furnace spill walls. As an exception, this spacing does not apply between a furnace and its own individual process and utility lines. This spacing minimizes the involvement of major plant pipeways in furnace fires. Spacing provided to minimize damage to equipment in case of a furnace fire or explosion. Equipment higher than 3 m shall be spaced 7.5 m from furnaces having liquid in the tubes. Compressor and Pump Drivers with High Skin Temperatures General: This spacing requirement is intended for drivers such as diesel engines, gasoline engines, steam turbines, and combustion gas turbines where elevated operating temperatures, develop as a characteristic of the unit, presenting a constant source of ignition for possible hydrocarbon releases. They do not create as positive an ignition source as an open flame in a furnace. Spacing Basic Distance, m. 10 From F-1 7.5 Remarks Provides spacing from hot surfaces on drivers to equipment handling hydrocarbons. Releases from such equipment will self-ignite and I-1, O-1 driver ignition source is not important. Spacing is P-1, Q-1 based on minimizing damage to the driver from other fire exposure. Provides access for operation and maintenance, and From G-1 3 © Saudi Arabian Oil Company, 2022 Saudi Aramco: Company General Use Page 23 of 42 Document Responsibility: Loss Prevention Standards Committee SAES-B-055 Issue Date: 16 August 2022 Next Revision: 20 August 2027 From H-1, J-1 H-1 Plant Layout 10 firefighting around associated pump or compressor. As an exception, this spacing does not apply to the particular compressor or pump being driven. Gas Compressors General: Equipment associated with the compressors, such as air cooled heat exchangers, knockout drums, etc., may be located in the compressor area and need not comply with the 7.5 m spacing to non-associated equipment, provided they do not restrict access for firefighting and maintenance. However, in such instances, fireproofing shall be in accordance with SAES-B-006. Access to compressors for firefighting purposes must be maintained on at least two sides of the installation. Compressors handling inert gases or air may be spaced closer to each other than is shown for gas compressors. Air intakes for air compressors must be located in a safe area as discussed in Section 7.2 of this standard. Steam or electric motor-driven gas compressors with less than 150 kW drivers may be treated as pumps for spacing and location purposes. Spacing Basic I-1 Distance, m. 7.5 G-1 10 H-1 3 Remarks Spacing provides a degree of protection to expensive compressor equipment from fires or explosions involving adjacent equipment, and vice-versa. As an exception, spacing does not apply to the driver for the particular compressor being driven. Spacing is based on the driver being a possible ignition source. Provides access for operation and maintenance, and allows increased firefighting access between units. Two compressors may be grouped in the same risk area, 7.5 m spacing would be required for firefighting access on at least two sides in this case. Pumps Handling Flammable Materials at Temperatures above 315°C General: Flammable liquid pumps shall not be placed beneath other equipment such as towers, drums, air-cooled heat exchangers, or pipeways, in order to avoid fire involvement of such equipment. They shall be located clear of overhead obstructions in order that they may be reached by mobile equipment for maintenance operations. Spacing Basic Distance, m. 5 From F-1 7.5 Remarks Since these flammable liquids are above their autoignition temperatures, they will ignite on release. Added spacing is provided between pumps, with their higher fire potential, and adjacent high valued equipment. Additional access is also provided for firefighting purposes. Furnaces do not represent a primary ignition source. Spacing based on minimizing damage if a release © Saudi Arabian Oil Company, 2022 Saudi Aramco: Company General Use Page 24 of 42 Document Responsibility: Loss Prevention Standards Committee SAES-B-055 Issue Date: 16 August 2022 Next Revision: 20 August 2027 Plant Layout From I-1 J-1 1.5 occurs, with a subsequent fire on either piece of equipment. Spacing allowable for pumps in the same service only. If in different services, even if both are operating at temperatures above 315°C, the basic spacing requirement of 5 m must be met. Pumps Handling Flammable Materials at Temperatures below 315°C General: Flammable liquid pumps present a higher fire potential so they shall be located away from ignition sources. Spacing Basic K-1 Distance, m. 3 Remarks Spacing minimizes damage in case of fire, by providing clear access for firefighting. Spacing less than I-1 since pumps operating below autoignition temperature of hydrocarbon do not represent as great of a fire risk as those operating above autoignition temperature. Cooling Towers General: Spacing requirements are based on dispersion of hydrocarbon vapors carried to cooling tower with return water, due to exchanger leakage. Cooling towers shall be located downwind or crosswind of buildings and equipment whenever possible. In addition, consideration is given to corrosion from water in the exhaust plume. Location of towers in relation to other equipment shall consider these effects. L-1 Spacing Basic Distance, m. 15 From High 30 Remarks Spacing provides reasonable distance for hydrocarbon vapors released with plume to be dispersed before reaching a source of ignition. Equipment that does not represent a source of ignition and is lower than the cooling tower shall be spaced 15 m away. Equipment higher than the cooling tower equipment shall be spaced a minimum of 30 m away because of impingement of the plume. Air Cooled Heat Exchangers General: Due to the extensive heat transfer surface and type of metals used for those surfaces, air-cooled heat exchanger bundles are highly vulnerable to damage within a few minutes under fire exposure. Air cooled heat exchangers shall be located on the opposite side of the plant, away from furnaces, to avoid ignition in case of air cooled heat exchanger leakage. They shall not be located over equipment listed in A1.2.4.2, which may have a relatively higher fire potential. Location over major pipeways with equipment on both sides shall be carefully considered. This is based on limited firefighting access, and the maintenance difficulties that are introduced. When layout dictates that © Saudi Arabian Oil Company, 2022 Saudi Aramco: Company General Use Page 25 of 42 Document Responsibility: Loss Prevention Standards Committee SAES-B-055 Issue Date: 16 August 2022 Next Revision: 20 August 2027 Plant Layout they be located above major pipeways, then the following requirements shall be applied: a) A minimum clearance of 3 m shall be provided between the lowest part of the air-cooled heat exchanger, excluding the motor, and the top of the pipe rack. In case an access platform is provided below the heat exchanger, the clearance shall be measured from the platform surface. b) Flanges and valves shall be minimized in all hydrocarbon lines below the air-cooled heat exchanger. c) The horizontal spacing requirements as given in Figure 1 from both the air-cooled heat exchanger and the pipeway shall be met. d) Access shall be provided for mobile equipment used in the removal or replacement of the air-cooled heat exchanger units. e) Supports for the air-cooled heat exchanger and pipeway shall be fireproofed if so required by SAES-B-006. Spacing Basic From M-1, R-1, Distance, m. 3 - S-1, T-1 M-1 Distance, m. 1.5 Remarks Spacing is primarily to provide access for operating and maintenance; it also allows some access for firefighting. Towers and Columns Spacing Basic O-1 heat exchangers, subject to general requirements. Drums Spacing Basic N-1 Remarks Spacing to minimize fire exposure to air-cooled heat exchangers, since they are more vulnerable to fire damage than shell and tube exchangers. This equipment can be located beneath air cooled Distance, m. 3 Remarks This spacing provides access for operation and maintenance, with some additional spacing for firefighting access. Reactors above 315°C (Internally Insulated) General: Releases from connections on reactors operating at temperatures above 315°C are expected to auto ignite. Reactors operating at temperatures below 315°C shall be treated as columns for spacing purposes. Spacing Basic Distance, m. 7.5 Remarks Spacing provides protection to exposed shells, and also provides access for firefighting. Internally lined reactors © Saudi Arabian Oil Company, 2022 Saudi Aramco: Company General Use Page 26 of 42 Document Responsibility: Loss Prevention Standards Committee SAES-B-055 Issue Date: 16 August 2022 Next Revision: 20 August 2027 P-1 Plant Layout From L-1 5 From O-1 1.5 From S-1 5 are more susceptible to fire damage than unlined vessels. An air-cooled heat exchanger fire would not be expected to expose reactor; thus reduced spacing allowed, based upon fire exposure from reactor to fin fan. Access is provided for operation and maintenance. Reactors in same service may be grouped together for operating efficiency. Spacing minimizes damage to structures during a reactor fire, and also provides access for firefighting, around the base of the reactor. Spacing to equipment within structure must meet individual spacing requirements. Reactors above 315°C (Externally Insulated) General: Releases from connections on reactors at temperatures above 315°C are expected to auto ignite. Reactors below 315°C may be treated as columns for spacing purposes. Q-1 Spacing Basic Distance, m. 5 From P-1 1.5 Remarks Damage to other equipment is minimized by spacing. Spacing takes into account the protection afforded from fires on other equipment by the external insulation. Access for firefighting is also provided. Spacing provides access for operation and maintenance. Reactors in same service may be grouped in the same area. Exchangers Operating Above 315°C General: The spacing requirements for this item apply to any exchanger containing flammable materials above 315°C inlet temperature, where auto ignition on release is expected. R-1 Spacing Basic Distance, m. 5 From F-1 7.5 From Q-1 1 Remarks Spacing minimizes damage to adjacent equipment and also provides some access for firefighting. The probability of fire is greater than with exchangers operating below 315°C. Spacing provides for more distance between the exchanger and a furnace, since releases from cold side of exchanger may not autoignite or ignite from hot side flanges of the exchanger. Exchangers which are directly connected by a process stream and operating above 315°C may be spaced as shown. The basic 5 m spacing shall be applied to other exchangers. Exchangers Operating Below 315°C General: Spacing is less since any flammable materials released will © Saudi Arabian Oil Company, 2022 Saudi Aramco: Company General Use Page 27 of 42 Document Responsibility: Loss Prevention Standards Committee SAES-B-055 Issue Date: 16 August 2022 Next Revision: 20 August 2027 Plant Layout generally be below their autoignition temperatures. Spacing Basic From R-1 S-1 Distance, m. 1.5 1 Remarks Primarily provides access for operation and maintenance. For exchangers in similar service. Main Equipment Structures General: Spacing to the structure from other equipment is primarily to provide access for maintenance operation and firefighting, and to minimize fire exposure to the structure. T-1 U-1 Onsite Pipeways Spacing Basic Distance, m. 5 From J-1 1.5 Remarks Spacing is primarily provided between pipeways and equipment to allow for operation and maintenance, and to reduce involvement from fires in adjacent equipment. Equipment handling flammables shall not be located under or above pipeways. There is no spacing requirement relative to motor or steam turbine drivers from pipeways. Same comment on drivers as for I-1. Reduced spacing is permitted to minimize need for extra pipe supports for handling the pump piping on and off the pipeway. Onsite Pressure Storage Vessels General: Offsite locations for this type of vessel shall be used if not otherwise dictated by process reasons. The inventory of onsite pressure storage shall be held to a minimum. The location of such vessels shall be at the unit boundary, at a minimum of 15 m from furnaces and other sources of ignition. This category covers refrigeration or other accumulator vessels of over 40 m³ normal capacity, containing pentane or lighter flammable liquids. V-1 Spacing Basic Distance, m. 25 From U-1 1.5 x Dia. Remarks Spacing is to minimize exposure to other plant equipment from a potential source of prolonged, severe fire. It also minimizes ignition potential in case of light hydrocarbon release from this equipment. Provides spacing between vessels for firefighting operation, and maintenance access. Blowdown and Water Disengaging Drums The listed spacing is based on blowdown or water disengaging drums that are vented to a flare system. Spacing Basic Distance, m. 7.5 Remarks This equipment shall be located in a separate unit area in order to avoid its involvement in plant fires. © Saudi Arabian Oil Company, 2022 Saudi Aramco: Company General Use Page 28 of 42 Document Responsibility: Loss Prevention Standards Committee SAES-B-055 Issue Date: 16 August 2022 Next Revision: 20 August 2027 W-1 Plant Layout Equipment Handling Non-Flammables Spacing Basic Distance, m. - From F-1 5 Remarks No basic spacing is required for this equipment. However, adequate spacing must be provided for operation and maintenance. Spacing established to minimize damage to equipment I-1, O-1, in case of fire in equipment where released materials P-1, Q-1 will normally be ignited. © Saudi Arabian Oil Company, 2022 Saudi Aramco: Company General Use Page 29 of 42 A1.4 Offsite Spacing-Guide to Figure 2 Commentary Note: The notation “From A-2, B-2”, etc., found in the spacing discussions of various items, refers to the spacing between the equipment with those reference letters in Figure 2 and the particular item being discussed. A-2 B-2 Process Areas Spacing Basic Distance, m. 45 From A-2 15 to 25 Remarks Spacing to limit damage to other equipment in case of fire or explosion in process area, and vice-versa. Spacing between process areas allows them to be shutdown independently for test and inspection with general area hot work permits. This is based on LPG, NGL, and high-risk type refinery units. For low-pressure crude handling, such as in stabilizer plants and crude distillation plants, this spacing can be reduced to 15 meters. Where a number of process units are integrated into one process area and shutdown together, the internal spacing shall be based on operation and maintenance requirements, access for firefighting, and spacing between fire-risk areas. Major Shipping Pump Areas General: This involves those pumps whose loss would significantly reduce the capability of delivering crude or products to major pipelines or marine tanker terminals. Spacing Basic C-2 Distance, m. 45 Blending and Booster Pumps Spacing Basic Distance, m. 25 From G-2, - H-2, I-2, J-2 D-2 Remarks Spacing allows access for firefighting and will minimize damage to pumps in case of fire or explosion in other equipment. Remarks Spacing provides protection to pumps from fire or explosion in other equipment, as well as exposure from pump fires. Spacing set by risk of pumps to storage tanks. As a minimum, the pumps must be outside the tank dikes. Major Offsite Pipeways General: Piping which interconnects plants, or plants and storage vessels, must be routed such that it will not remain in service through plant areas that are shut down for turnaround. Pipeways must be outside the dikes protecting any product or crude oil storage vessels. Cross Country Pipelines: Cross-country transportation pipelines outside plant areas shall be spaced according to SAES-B-064. Previous Revision: 28 October 2021 Contact: Ghamdi, Hatem S (GHAMHS0A) © Saudi Arabian Oil Company, 2022 Saudi Aramco: Company General Use Next Revision: 20 August 2027 Page 30 of 42 Document Responsibility: Loss Prevention Standards Committee SAES-B-055 Issue Date: 16 August 2022 Next Revision: 20 August 2027 Spacing Basic Distance, m. 7.5 From M-2 - From N-2 15 From S-2, 15 T-2 From U-2 E-2 Plant Layout 100 Remarks Spacing provides for minimizing damage to pipeways in the event of a plant fire or explosion in major plant equipment. Personnel shall be protected from electric shocks per SAES-B-064. Added spacing provided to minimize exposures to normally occupied buildings. Spacing is minimum for buried line. A minimum spacing of 60 m is required for aboveground piping. Major offsite pipeways offer little risk to wells. This spacing is based on exposure from a well blowout fire. Storage Facilities for Chemicals General: This category covers storage for chemicals. Spacing Basic F-2 Distance, m. 30 Remarks This spacing provides separation from major equipment handling hydrocarbons which could be involved in sustained fires. This will prevent the overheating of chemicals. Loading Racks for LPG General: Liquefied Petroleum Gas (LPG) loading racks for road tank trucks shall be consolidated at one location at the periphery of the main plant facilities. This location shall be near an access gate (other than main gate), so that traffic through the plant is minimized and high-risk areas are avoided. Refer to SAES-B-070 for further details. Tank truck loading racks must be provided with adequate space and roadways for safe truck driving and parking, as well as safe access to and from loading racks and weight-scales where included. Spacing Basic G-2 Distance, m. 60 Remarks This spacing allows for dispersion of vapors that may be released at the rack when making or breaking connections, or in case of a loading arm failure. Damage to other equipment in case of a fire at the rack is also minimized, and vice-versa. Pressure Storage Vessels General: This category includes storage vessels (spheres and spheroids, bullets, dome roof tanks, horizontal storage tanks, etc.) that store fluids with a true vapor pressure higher than 90 kPa(abs). Releases from this equipment can result in large vapor clouds. Also, fires associated with such storage are difficult to handle and constitute a high risk of vessel failure with sudden release of the entire vessel contents. These vessels © Saudi Arabian Oil Company, 2022 Saudi Aramco: Company General Use Page 31 of 42 Document Responsibility: Loss Prevention Standards Committee SAES-B-055 Issue Date: 16 August 2022 Next Revision: 20 August 2027 Plant Layout shall be located down slope and downwind from plant areas or other critical facilities or residential areas. There shall be no other equipment inside the diked areas of these vessels, excepting associated piping. The vessel shell shall be at least 15 m inside the dike wall, with the associated equipment, i.e., pumps, at least 7.5 m from outside the dike. Commentary Note: Any expansion of plant facilities downwind of these vessels shall include an impact assessment of potential large vapor release and fires associated with these vessels. Spacing Basic H-2 Distance, m. 60 From H-2, I-2 60 From J-2 30 Remarks This spacing provides separation from major plant facilities such as processing areas and buildings. Protection is also provided for the pressure storage vessels in case of fire or explosion at other facilities. This distance may be reduced I-2 depending upon the size of the storage vessel. Refer to SAES-B-005. Reduced spacing allowed due to nature of stocks in atmospheric storage tanks. Refer to SAES-B-005. Atmospheric and Low Pressure Storage of Low-Flash Stocks General: Low-flash stocks are fluids with true vapor pressure less than 90 kPa(abs) and a flash point under 54°C and any other fluid that may be stored at temperatures above or within 8°C of its flash point. These normally will be floating roof tanks. Tanks shall be placed down slope from plants or other critical facilities or residential areas. The spacing between the tank shell and the dike shall meet SAES-B-005. Except for associated piping, there shall not be any equipment within the diked area of these tanks. Spacing Basic I-2 Distance, m. 60 Remarks Spacing is based on large tanks and is reasonable to permit containment of a tank fire and keep it from involving other facilities. It will also protect the tanks in case of fires and explosion at other facilities. This is a maximum spacing, it may be reduced. Refer to SAES-B-005. Refrigerated Storage General: Covers low-pressure dome roof tanks of up to 17.5 kPa(ga) design pressure which are insulated to handle refrigerated liquefied gases of pentane and lighter flammables. Any spillage will pick up heat from the ground and atmosphere and create large flammable vapor clouds. Fires in such facilities are difficult to handle. This storage shall be located down slope and downwind from process areas or other critical facilities or residential areas. The spacing between the tank shell and the dike shall meet SAES-B-005. Equipment other than associated piping shall not be © Saudi Arabian Oil Company, 2022 Saudi Aramco: Company General Use Page 32 of 42 Document Responsibility: Loss Prevention Standards Committee SAES-B-055 Issue Date: 16 August 2022 Next Revision: 20 August 2027 Plant Layout located within diked areas of storage vessels. Spacing Basic J-2 Distance, m. 60 Remarks Spacing is based on large (more than 60 m diameter) refrigerated tanks, and is provided to permit containment of a tank fire to prevent involving other facilities. Also, it minimizes chances of ignition in case of small spills. Protection is also afforded to this tankage in case of fire at other facilities. Spacing may be reduced if the vessels are less than 60 m in diameter. Refer to SAES-B-005. Atmospheric Storage of High-Flash Stocks General: High-flash Stocks are fluids having a flash point over 54°C, stored at temperatures more than 8°C below the flash point. Tanks shall be located down-slope and down-wind from process areas or other critical facilities or populated areas. Area within dike of storage vessel must be free of all equipment other than associated piping. The spacing between the tank shell and the dike shall meet SAES-B-005. Spacing Basic K-2 Distance, m. 30 Remarks High-flash stocks as defined represent a reduced fire hazard; therefore, a reduced spacing is called for as compared to the low-flash stocks. This spacing primarily provides for avoiding damage to this tankage from fire or explosion in adjacent facilities. Spacing may vary with size of tank. Refer to SAES-B-005. Boiler Houses, Power Generating Facilities General: These facilities are critical to the continued operation of the plant or refinery. They represent constant sources of ignition for any hydrocarbon releases from plant process areas. They shall, therefore, be placed away from process areas as far as possible, consistent with operating demands. Spacing Basic Distance, m. 45 From N-2 30 From P-2 45 Remarks Spacing provides protection for these critical facilities from possible fire or explosion in equipment handling hydrocarbons. Steam generators which supply less than 25% of the total steam demand for a refinery or other multi-plant facility, or which supply steam only to a particular plant within that facility, may be located nearer operating equipment with spacing as for furnaces. Reduced spacing allowed since boiler and generating stations constitute only a minor risk to these type facilities. Conversely, N-2 facilities do not represent a hazard to boilers or generating facilities. Spacing may be reduced to 30 m if the adjoining property has only buildings or other facilities affording little risk to the boiler plant/generating facilities. © Saudi Arabian Oil Company, 2022 Saudi Aramco: Company General Use Page 33 of 42 Document Responsibility: Loss Prevention Standards Committee SAES-B-055 Issue Date: 16 August 2022 Next Revision: 20 August 2027 L-2 Plant Layout Major Electrical Distribution Centers General: These facilities are considered critical to the operation of multiplant facilities. As a minimum, they shall be placed in a non-classified electrical area, as defined in SAES-B-068. Spacing Basic M-2 Distance, m. 45 Remarks Spacing to protect this critical equipment from potential fire or explosion in equipment processing or handling hydrocarbons. Loss of electrical centers would result in shutdown of major plants of the facility. Main Overhead Power Lines General: These are normally high voltage power lines and they shall be routed away from process areas and tank farms. These power lines are critical to operations and shall be protected from fires or explosions in other facilities, as these could cause a failure of the main electrical supply. N-2 Spacing Basic Distance, m. 60 From D-2 - Remarks Minimum spacing to provide protection from fires or explosions in operating equipment or tankage. Personnel shall be protected from electric shocks per SAES-B-064. Buildings (Offices, Workshops, Laboratories, Firehouses, etc.) General: These facilities represent essentially no exposure to other facilities. Spacing is the minimum to protect personnel in these buildings from fires or explosions in equipment handling or storing hydrocarbons. Spacing may be greater, depending on the building risk assessment. Refer to the requirements of SAES-B-014 for details. O-2 Spacing Basic Distance, m. 45 From A-2, 60 Remarks Minimum spacing to provide protection to buildings and personnel from possible fire or explosion in major equipment. However, spacing may be greater, depending on the building risk assessment. See SAES-B-014. Additional spacing is provided from these facilities, B-2, F-2, mainly for personnel protection. However, spacing G-2, H-2, I-2 may be greater, depending on the building risk assessment. See SAES-B-014. Main Fire Pumps General: These pumps may well represent the difference between minor damage by fire or explosion and the loss of an entire process unit or plant or tankage area. Spacing Distance, m. Remarks © Saudi Arabian Oil Company, 2022 Saudi Aramco: Company General Use Page 34 of 42 Document Responsibility: Loss Prevention Standards Committee SAES-B-055 Issue Date: 16 August 2022 Next Revision: 20 August 2027 P-2 Plant Layout Basic 45 From Q-2 15 This spacing is to prevent the main fire pumps from becoming involved in a fire or explosion occurring in major plant hydrocarbon handling equipment. Special purpose fire pumps, such as those for special risk protection systems, may be spaced closer to facilities not being protected by this system. Reduced spacing permitted since exposure to fire pumps can be controlled. Property Lines General: Spacing from property lines is primarily provided to minimize the exposure of others to damage from a fire or explosion within the plant itself. Its application must be considered on the basis of the associated exposures. Other security related spacing requirements may apply, refer to SAES-O-202. Spacing Basic Distance, m. 60 From J-2 45 From L-2 - N-2, O-2 Q-2 R-2 Remarks Spacing provides protection between plant facilities and the nearest point which may be built upon or traveled by others. It also provides protection to plant equipment, regardless of the occupancy that may develop in the future on adjacent property. Reduced spacing is permitted based upon the small fire risk involved. Minimum operational and maintenance access spacing is acceptable if the facilities on adjoining property are of the low risk type. Greater spacing shall be used if process plants, storage tanks or other similar risks are located adjacent to the property line. In these cases, spacing similar to internal plant requirement shall be used. Fire Training Ground Spacing Basic Distance, m. 45 From D-2 15 Remarks Spacing provides separation of the source of ignition of the training ground from equipment handling hydrocarbons. It also allows for dispersal of the smoke produced; thus, minimizing the effect on personnel in the plant areas. Increased spacing for pipebands is provided in view of regular spill fires on training grounds. Oil-Water Separators and Skimming Ponds General: This relates to spacing to facilities unassociated with the oilwater separator or skim pond. Spacing within the facility to pumps, small slop tanks, or treating facilities would be developed specifically. Spacing Basic Distance, m. 45 Remarks Spacing provides separation from operating areas and © Saudi Arabian Oil Company, 2022 Saudi Aramco: Company General Use Page 35 of 42 Document Responsibility: Loss Prevention Standards Committee SAES-B-055 Issue Date: 16 August 2022 Next Revision: 20 August 2027 Plant Layout other sources of ignition, to prevent hydrocarbon vapors discharged at the separator from igniting. It also minimizes exposure from fires at the separators. Spacing may be reduced to low risk facilities that do not represent a source of ignition, or where exposure risk is minimal. S-2 Elevated Flare General: The design basis for spacing has to take into account the amount of heat liberated at the flare and the amount of heat that can be tolerated by personnel and equipment for various situations. The spacing given in Figure 2 are basic minimums; the actual spacing used shall be those resulting from design calculation on the particular flare under consideration. Refer to SAES-F-007 for details. A flare is considered to be elevated when its height is more than 15 m. Spacing Basic Distance, m. 60 From D-2 15 From V-2 500 Remarks Spacing is nominally based on the radius of fallout of entrained liquid or solid particles (from flare to ignitable materials). Radiant heat factor to personnel and equipment must also be considered in design calculations. Reduced spacing for buried lines. Distance shall be at least 60 m from aboveground lines, unless radiant heat calculations indicate that additional spacing is necessary. This is a minimum spacing. Distance shall be at least 500 m from Main Office Buildings. The actual distance may be greater based on the design calculations, radiant heat and flare-out considerations etc. for the specific flare. Refer to SAES-F-007 for details. Additional Offshore GOSP Flare Requirements: Flares shall be located in the southwest quadrant, 90 degrees from a downwind direction of the GOSP. Where there is a submarine line from the platform to the flare structure, a minimum distance of 550 m is required to reduce the effect of released hydrocarbon liquid. T-2 Burn Pits and Ground Flares General: The listed spacing is a bare minimum. They are primarily intended to reduce the effects of smoke on personnel and equipment in nearby facilities and on residential or public areas. The radiant heat effects on personnel and equipment must be included in spacing calculations, as required by SAES-F-007. For burn pits and ground flares that are associated with the operations of wells and pipelines, the requirements of SAES-B-062 and SAES-B-064 shall be applied. Spacing Distance, m. Remarks © Saudi Arabian Oil Company, 2022 Saudi Aramco: Company General Use Page 36 of 42 Document Responsibility: Loss Prevention Standards Committee SAES-B-055 Issue Date: 16 August 2022 Next Revision: 20 August 2027 Plant Layout Basic 150 From D-2 15 Basically provides for dispersal of smoke from flares or burn pits. Radiant heat effects must be considered also, as well as prevailing wind conditions. Minimum spacing from buried lines. Spacing for aboveground lines shall be at least 150 meters from ground flares and 60 meters from burn pits unless radiant heat calculations indicate otherwise. Onshore GOSP Flare Location Requirements The basic spacing given in Figure 2 are generally bare minimums. Actual spacing shall be calculated based on radiant heat effects on personnel and adjacent equipment. The reliability of the flare light off system and the possible exposure of adjacent equipment and personnel due to un-ignited releases during start-up shall also be considered. In the absence of calculations, the following spacing shall be used as minimums for ground flares: a) 450 m from producing oil/gas wells. b) 150 m from offsite pipeways, unless buried lines. c) 450 m from plot-limits of GOSP. d) 450 m from major public roadways. The flare shall be located such that glare from it does not interfere with the night vision of vehicle drivers on the GOSP access road, or nearby public roads. The following minimum spacing to burn pits shall be observed, unless calculations indicate otherwise: U-2 a) 150 m from GOSP plot-limits b) 150 m from overhead electrical transmission lines c) 90 m from the GOSP ground flare d) 60 m from above ground oil/gas lines e) 15 m from buried oil/gas lines Oil/Gas Wells General: For wells, see SAES-B-062 for details on how to calculate the minimum required spacing. Spacing Basic Distance, m. SAES-B-062 From R-2, 100 Remarks Rupture exposure radius is calculated for each well to determine the minimum required spacing from facilities and population. See SAES-B-062 for details. Flares and burnpits of plants or GOSPs shall be located downwind and crosswind of any oil/gas well. Lack of ignition source and low relative degree of © Saudi Arabian Oil Company, 2022 Saudi Aramco: Company General Use Page 37 of 42 Document Responsibility: Loss Prevention Standards Committee SAES-B-055 Issue Date: 16 August 2022 Next Revision: 20 August 2027 Plant Layout exposure risk allows reduction in basic spacing. V-2 Main Office Buildings Main Office Buildings shall be located outside of plant perimeter fences in an area free of hazards from oil and gas processing and handling installations, and shall be located upwind or crosswind of the prevailing wind direction of such facilities. Main Office Buildings shall not be located within 500m of plant perimeter fences, unless it can be shown through a Building Risk Assessment (BRA) study that it is tolerable with costeffective measures to bring these buildings closer to the fence. The BRA shall include potential future expansions in the process units, if any, and their impact on siting high-population buildings. Spacing Basic W-2 Distance, m. 500 Remarks Under normal weather conditions, this minimum spacing from a hydrocarbon processing plant area perimeter fence provides a main office building with a significant reduction in risk from hazards from oil and gas handling installations. Wind Turbine Generators (WTG) The basic spacing from a wind turbine generator to any other equipment depends on the WTG size; this basic spacing is the addition of tower height (H) and blade length (R). It is sufficient to address objectives set in 5.3 as well as preventing any damage to nearby equipment resulting from a tower collapse. Reduction of this basic spacing is possible if supported by a Quantitative Risk Assessment (QRA) reviewed by the Loss Prevention Technical Services Department, Technical Services Unit. Besides safety, WTG may generate noise and shadow flickers that could impact occupants for long term exposure. For company buildings, shops, labs and firehouses and for residential areas, the spacing distance shall be 500 m. Reduction of these distances is possible if supported by a noise modelling study and a flicker effect study approved by EPD. Spacing Basic From N-2 From V-2 X-2 Distance, m. Remarks H+R Balance of plant equipment related to the WTG (e.g., transformer) is allowed within this spacing zone. 500 m 500 m Residential Areas Residential areas shall be kept free of hazards due to oil and gas processing and handling installations and shall be located upwind or crosswind of the prevailing wind direction of such facilities. The prevailing © Saudi Arabian Oil Company, 2022 Saudi Aramco: Company General Use Page 38 of 42 Document Responsibility: Loss Prevention Standards Committee SAES-B-055 Issue Date: 16 August 2022 Next Revision: 20 August 2027 Plant Layout wind direction applicable to a particular location shall be per SAES-A-112. A Quantitative Risk Assessment (QRA) and Environmental Impact Assessment (EIA) per SAEP-13 shall be conducted to determine the required spacing. The QRA and EIA shall include potential future expansions in the process units and associated pipelines; and their impact on siting such areas. In no case shall residential areas be located closer than 500 m from the plant perimeter fence of any hydrocarbon facility. In order to quantify the land use development within the vicinity of Saudi Aramco hydrocarbon facilities, Location Specific Individual Risk (LSIR) contours shall be developed for all new facilities. Spacing Basic Distance, m. 500 Remarks Under normal weather conditions, this minimum spacing from a hydrocarbon processing plant area perimeter fence provides a residential area with a significant reduction in risk from hazards from oil and gas handling installations. © Saudi Arabian Oil Company, 2022 Saudi Aramco: Company General Use Page 39 of 42 Document Responsibility: Loss Prevention Standards Committee SAES-B-055 Issue Date: 16 August 2022 Next Revision: 20 August 2027 Plant Layout Figure 1 - Onsite Spacing Chart Furnaces, Heaters, and Boilers Compressor/Pump Drivers with High Skin Temp. o o Gas Compressors Pumps Handling Flammable Materials At o Temperatures Above 315 C Pumps Handling Flammable Materials At Temperatures Below 315oC Cooling Towers Air Cooled Heat Exchangers Drums Towers and Columns Exchangers Operating below 315 C Main Equipment Structures Onsite Pipeways Onsite Pressure Storage Vessels Blowdown and Water Disengaging Drums Equipment Handling Non-Flammables B-1 C-1 D-1 E-1 F-1 G-1 H-1 I-1 J-1 K-1 L-1 M-1 N-1 O-1 P-1 Q-1 R-1 S-1 T-1 U-1 V-1 W-1 o Exchangers Operating above 315 C Critical Electrical Switchracks Emergency Valves for Isolation, Water Sprays, etc. A-1 Reactors above 315 C (externally insulated) Plant Electrical Load Centers or Substations Reference Letter o Control Buildings FACILITY Satellite Instrument Buildings Basic Spacing FACILITY Note: This chart gives basic minimum spacings and must be used only in conjunction with the Onsite Spacing Guide for Figure 1. BASIC SPACING (far left-hand column) is the distance to be maintained if not indicated in the chart. Reactors above 315 C (internally insulated) KEY: A: Provide spacing based on access for operation and maintenance. B: As required, see Appendix. C: One and a half times diameter of the largest tank. D: Apply basic spacing or the electrically classified area whichever is greater. E: Provide separation between buildings based on access for operation, maintenance and firefighting and Saudi Aramco Building Code (SAES-M-100) requirements for fire separation distance; whichever is greater. Reference Letter 30 Control Buildings A-1 E E E A 15 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 A A-1 15 Satellite Instrument Buildings B-1 E E E A 5 15 15 15 15 15 15 15 15 15 15 15 15 15 15 5 25 15 A B-1 15 Plant Electrical Load Centers or Substations C-1 E E E A 7.5 15 A D D D 15 15 15 15 15 15 15 15 15 5 25 15 A C-1 7.5 Critical Electrical Switchracks D-1 A A A A A 15 A 7.5 7.5 7.5 15 A 7.5 7.5 7.5 7.5 7.5 7.5 7.5 7.5 25 25 25 D-1 15 Emergency Valves for Isolation, Water Sprays, Snuffing Steam, etc. E-1 15 5 7.5 A A 15 7.5 15 15 15 A 7.5 7.5 7.5 15 15 15 15 7.5 A 25 7.5 A E-1 15 Furnaces, Heaters, and Boilers F-1 30 15 15 7.5 15 B 7.5 25 7.5 15 30 15 15 15 7.5 5 7.5 15 15 7.5 25 25 5 F-1 10 Compressor/Pump Drivers with High Skin Temp. G-1 30 5 A A 7.5 7.5 3 10 7.5 10 15 10 10 10 7.5 7.5 7.5 10 10 5 25 10 A G-1 Gas Compressors H-1 30 15 D 7.5 15 25 10 3 7.5 7.5 15 7.5 7.5 7.5 7.5 7.5 7.5 7.5 7.5 5 25 7.5 A H-1 I-1 30 15 D 7.5 15 7.5 7.5 7.5 1.5 5 15 5 5 5 7.5 5 5 5 5 5 25 7.5 5 I-1 J-1 30 15 D 7.5 15 15 10 7.5 5 1 15 3 3 3 7.5 5 5 3 3 1.5 25 7.5 A J-1 K-1 7.5 5 3 Pumps Handling Flammable Materials At Temperatures Above 315 oC Pumps Handling Flammable Materials o At Temperaturs Below 315 C 15 Cooling Towers K-1 30 15 15 15 A 30 15 15 15 15 A 15 15 15 15 15 15 15 15 5 25 15 A 3 Air Cooled Heat Exchangers L-1 30 15 15 A 7.5 15 10 7.5 5 3 15 A B 3 5 5 5 B B B 25 7.5 A L-1 1.5 Drums M-1 30 15 15 7.5 7.5 15 10 7.5 5 3 15 B 1.5 1.5 7.5 5 5 1.5 B 1.5 25 7.5 A M-1 N-1 30 15 15 7.5 15 15 10 7.5 5 3 15 3 1.5 3 7.5 5 5 1.5 B 3 25 7.5 A N-1 O-1 30 15 15 7.5 15 7.5 7.5 7.5 7.5 7.5 15 5 7.5 7.5 1.5 7.5 7.5 7.5 5 5 25 7.5 5 O-1 P-1 30 15 15 7.5 15 5 7.5 7.5 5 5 15 5 5 5 7.5 1.5 5 5 5 5 25 7.5 5 P-1 3 Towers and Columns 7.5 Reactors above 315 C (internally insulated) Reactors above 315 oC (externally insulated) o 5 o 5 Exchangers Operating above 315 C Q-1 30 15 15 7.5 15 7.5 7.5 7.5 5 5 15 5 5 5 7.5 5 1 5 5 5 25 7.5 5 Q-1 1.5 Exchangers Operating below 315 oC R-1 30 15 15 7.5 7.5 15 10 7.5 5 3 15 B 1.5 1.5 7.5 5 5 1 B 1.5 25 7.5 A R-1 B Main Equipment Structures S-1 30 15 15 7.5 7.5 15 10 7.5 5 3 15 B B B 5 5 5 B A 5 25 7.5 A S-1 5 Onsite Pipeways T-1 30 5 5 7.5 A 7.5 5 5 5 1.5 5 B 1.5 3 5 5 5 1.5 5 A 5 5 A T-1 25 Onsite Pressure Storage Vessels U-1 30 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 5 C 25 A U-1 7.5 Blowdown and Water Disengaging Drums V-1 30 15 15 7.5 7.5 25 10 7.5 7.5 7.5 15 7.5 7.5 7.5 7.5 7.5 7.5 7.5 7.5 5 25 A A V-1 A Equipment Handling Non-Flammables W-1 A A A A A 5 A A 5 A A A A A 5 5 5 A A A A A A W-1 Reference Letter A-1 B-1 C-1 D-1 E-1 F-1 G-1 H-1 I-1 J-1 K-1 L-1 M-1 N-1 O-1 P-1 Q-1 R-1 S-1 T-1 U-1 V-1 W-1 Reference Letter © Saudi Arabian Oil Company, 2022 Saudi Aramco: Company General Use Page 40 of 42 Document Responsibility: Loss Prevention Standards Committee SAES-B-055 Issue Date: 16 August 2022 Next Revision: 20 August 2027 Plant Layout Figure 2 - Offsite Spacing Chart KEY: Blending and Booster Pumps Major Offsite Pipeways Chemical Storage Loading Racks for LPG Pressure Storage Vessels Atmospheric Storage of LowFlash Stocks Refrigerated Storage Atmospheric Storage of HighFlash Stocks Boiler Houses, Power Generating Facilities Major Electrical Distribution Centers Main Overhead Power Lines Buildings, Shops, Labs, Firehouses Main Fire Pumps Property Lines Fire Training Grounds Oil-Water Separators and Skimming Ponds Elevated Flare Stacks Burn Pits and Ground Flares Oil / Gas Wells Main Office Buildings Wind Turbine Generators Residential Areas FACILITY Process Areas Basic Spacing Major Shipping Pump Areas U: Sum of tower height and rotor radius. V: As required by SAES-B-062. W: As required by SAES-B-064. X: Provide separation based on access for operation and maintenance Y: As required, see Appendix. Z: As required by SAES-B-005. Note: This chart gives basic minimum spacings and must be used only in conjunction with the Offsite Spacing Guide for Figure 2. BASIC SPACING (far left-hand column) is the distance to be maintained if not indicated in the chart. FACILITY T: Provide separation between buildings based on access for operation, maintenance and firefighting and Saudi Aramco Building Code (SAES-M-100) requirements for fire separation distance; whichever is greater. Reference Letter A-2 B-2 C-2 D-2 E-2 F-2 G-2 H-2 I-2 J-2 K-2 L-2 M-2 N-2 O-2 P-2 Q-2 R-2 S-2 T-2 U-2 V-2 W-2 X-2 Reference Letter 45 Process Areas A-2 25 45 25 7.5 45 60 60 60 60 30 45 45 60 60 45 60 45 45 60 150 V 500 U 500 A-2 45 Major Shipping Pump Areas B-2 45 X X 7.5 45 60 60 60 60 30 45 45 60 60 45 60 45 45 60 150 V 500 U 500 B-2 25 Blending and Booster Pumps C-2 25 X X 7.5 25 25 Y Y Y Y 45 45 60 45 45 60 45 25 60 150 V 500 U 500 C-2 7.5 Major Offsite Pipeways D-2 7.5 7.5 7.5 Y 7.5 7.5 7.5 7.5 7.5 7.5 7.5 7.5 W 15 7.5 7.5 15 7.5 15 15 100 500 U 500 D-2 30 Chemical Storage E-2 45 45 25 7.5 T 60 60 60 60 30 45 45 60 T 30 60 45 45 60 150 V 500 U 500 E-2 60 Loading Racks for LPG F-2 60 60 25 7.5 60 Y 60 60 60 30 60 60 60 60 60 60 60 45 60 150 V 500 U 500 F-2 60 Pressure Storage Vessels G-2 60 60 Y 7.5 60 60 Z 60 60 30 60 60 60 60 60 60 60 60 60 150 V 500 U 500 G-2 60 Atmospheric Storage of Low-Flash Stocks H-2 60 60 Y 7.5 60 60 60 Z Z Z 60 60 60 60 60 60 60 60 60 150 V 500 U 500 H-2 60 Refrigerated Storage I-2 60 60 Y 7.5 60 60 60 Z Z Z 60 60 60 60 60 60 60 60 60 150 V 500 U 500 I-2 J-2 30 30 Y 7.5 30 30 30 Z Z Z 30 30 60 30 30 45 30 30 30 150 V 500 U 500 J-2 K-2 30 45 Atmospheric Storage of High-Flash Stocks Boiler Houses, Power Generating Facilities K-2 45 45 45 7.5 45 60 60 60 60 30 T X 60 30 X 45 45 45 60 150 V Y U Y 45 Major Electrical Distribution Centers L-2 45 45 45 7.5 45 60 60 60 60 30 X X 60 X X X 45 45 60 150 V 60 U 60 L-2 60 Main Overhead Power Lines M-2 60 60 60 W 60 60 60 60 60 60 60 60 Y 60 60 Y 60 60 60 150 V 60 U 60 M-2 45 Buildings, Shops, Labs, Firehouses N-2 60 60 45 15 T 60 60 60 60 30 30 X 60 T X X 45 60 60 150 V T 500 T N-2 45 Main Fire Pumps O-2 45 45 45 7.5 30 60 60 60 60 30 X X 60 X X X 15 45 60 150 V X U X O-2 60 Property Lines P-2 60 60 60 7.5 60 60 60 60 60 45 45 X Y X X Y 60 60 60 150 V Y U Y P-2 45 Fire Training Grounds Q-2 45 45 45 15 45 60 60 60 60 30 45 45 60 45 15 60 Y 45 60 150 V 500 U 500 Q-2 45 Oil-Water Separators and Skimming Ponds R-2 45 45 25 7.5 45 45 60 60 60 30 45 45 60 60 45 60 45 X 60 150 100 500 U 500 R-2 60 Elevated Flare Stacks S-2 60 60 60 15 60 60 60 60 60 30 60 60 60 60 60 60 60 60 X 150 V Y U Y S-2 150 Burn Pits and Ground Flares T-2 150 150 150 15 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 X V Y U Y T-2 V Oil / Gas Wells U-2 V V V V V V V V V V V V V V V V V 100 V V X V U V U-2 500 Main Office Buildings V-2 500 500 500 500 500 500 500 500 500 500 Y 60 60 T X Y 500 500 Y Y V T 500 T V-2 U Wind Turbine Generators W-2 U U U U U U U U U U U U U 500 U U U U U U U 500 U 500 W-2 500 Residential Areas X-2 500 500 500 500 500 500 500 500 500 500 Y 60 60 T X Y 500 500 Y Y V T 500 T X-2 Reference Letter A-2 B-2 C-2 D-2 E-2 F-2 G-2 H-2 I-2 J-2 K-2 L-2 M-2 N-2 O-2 P-2 Q-2 R-2 S-2 T-2 U-2 V-2 W-2 X-2 Reference Letter © Saudi Arabian Oil Company, 2022 Saudi Aramco: Company General Use Page 41 of 42 Document History Major revision to address changes as a result of CRM’s, Waivers, Consultations and propoosed changes to Residential and Main Office Building spacing requirements. 28 October 2021 Editorial revision to reflect the correct organization name. 3 July 2019 Editorial revision, to reflect content confirmation requirement. 20 August 2017 Aligned the requirements for placing satellite instrument buildings and plant main electrical load centers outside electrically classified areas with the requirements of SAES-B-068. Transferred roads and accessways requirements from SAES-B-054 to be more suitably included in this standard. Revised the spacing requirements for emergency valves in line with SAES-B-058, March 20, 2017 edition. Included the spacing requirements of wind turbine generators and other editorial changes. 35 March 2012 Revised the “Next Planned Update.” Reaffirmed the content of the document, and reissued with minor revision. 16 August 2022 Previous Revision: 28 October 2021 Contact: Ghamdi, Hatem S (GHAMHS0A) © Saudi Arabian Oil Company, 2022 Saudi Aramco: Company General Use Next Revision: 20 August 2027 Page 42 of 42
0
You can add this document to your study collection(s)
Sign in Available only to authorized usersYou can add this document to your saved list
Sign in Available only to authorized users(For complaints, use another form )