Energy Ready Reference Guide Gene ration • Di stribution • Transmi ssion R ay che m Cabl e A cc e s s orie s , C o nn e c to rs , Fitt ing s , S urg e Ar restors, Insul ators, C romp ton P ower Measu rement C ont rol TE Energy TE Energy is a global supplier to power utilities and power industry customers, equipment manufacturers, and transport systems, with nearly 4,000 employees. Home to Raychem and a number of other trusted product brands, our group offers a wide variety of products that provide reliable connectivity from generation to the end user. We have sales representatives in more than 80 countries and manufacturing sites in five continents. Our product range includes: • Cable Accessories • Connectors and Fittings • Insulators • Insulation and Wildlife Protection • Surge Arresters • Power Measurement and Control • Distribution Components • Street Lighting MEDIUM VOLTAGE CABLE ACCESSORIES APKT heat-shrinkable termination system for cables up to 36 kV ………………………………………… 2 EPKT terminations for polymeric and MIND paper insulated cables from 7.2 kV up to 36 kV ………………………………………………………………………… 5 IXSU-F/OXSU-F heat-shrinkable termination system with non-linear, zinc oxide stress control for polymeric cables up to 24 kV ………………………………………………… 8 EPKJ joints for screened plastic and rubber insulated cables upto 36 kV ……………………………… 11 MXSU/MXST/MXSW/MXAW jointing system up to 36 kV complete with mechanical connectors …… 13 SXSU/SXST/SXSW/SXAW joints for polymeric insulated cables from 12 kV up to 36 kV ………… 15 RICS insulated adapter termination system for SF6-insulated switchgear up to 24 kV …………… 17 RSRB heat shrinkable insulating bushing boots up to 36 kV …………………………………………… 19 CSJT silicone cold-shrink joint with inte grated stress control for XLPE cables up to 36 kV ……… 21 CSTI/CSTO silicone cold-shrink termination with integrated stress control for XLPE cables up to 24 kV …………………………………………………………………………… 22 ELBC - 810 screened separable connector up to 17.5 kV, 800 A ………………………………………… 24 ELBC - 824 screened separable connector up to 24 kV, 800 A ………………………………………… 26 RSTI-58 screened separable connector system, 800 A up to 24 kV …………………………………… 28 RSTI-68 screened separable connector system, 1250 A up to 42 kV ………………………………… 30 RSES 400 A screened, separable elbow connection system 400 A for 24 kV and 36 kV RSES / RSSS 250 A screened adaptor system 250 A, up to 24 kV RCAB elastomeric insulating bushing boot for bushings up to 630 A, 24 kV RPIT inner cone connector up to 52 kV, 1250 A ………… 32 …………………………………… 34 ……………………… 36 ……………………………………………………………… 38 Duyen Ha Power Equipment Co.,Ltd 1 Heat-Shrink Terminations APKT Heat-shrinkable termination system for cables up to 36 kV General Description Over the last three decades, engineers in utilities and industry around the world have specified million’s of Raychem cable terminations at distribution voltages up to 36 kV. Raychem terminations have become identified with reliability because of their unparalleled long-term performance – where it really counts – in the field. Today there are many changes influencing the distribution of power at medium voltages. MEDIUM VOLTAGE CABLE ACCESSORIES Features & Benefits 2 • All applications for polymeric and MIND paper on 1-core, 3-core, armoured and unarmoured cables • Red non-tracking Raychem HVOT tubing provides excellent environmental protection • Can be used in combination with Raychem RICS / RCAB / RSRB terminations • Enhanced range-taking ability means that one kit fits more conductor sizes, reducing stocking requirements • Unlimited shelf life allows stocking of economic quantities without product spoilage Simplifield cable • Components are lightweight and non-shattering • Clear instruction sheets • Fully sealed against water ingress from the environment or from within the conductor strands • Compatible with all state of the art screen removal techniques • No tapering of insulation required • No polishing of polymeric insulation surface • Factory engineered kit permits rapid on-site installation • No mechanical stress at insulation screen cutback • Termination accommodates same bending radius as cable • Visual confirmation of correct assembly sequence possible after installation • Rain skirts can be installed to allow either top or bottom feed • No soldering of earthing accessories required • Unsurpassed performance in polluted environments, proven over three decades. Duyen Ha Power Equipment Co.,Ltd Selection Information: dimensions shown in millimeters XXXX Product Family - XX X X X X -XX -T =APKT Voltage up to 7.2 kV =7 12 and 17.5 kV =17 24 kV =24 36 kV =36 7.2kV 12/17.5kV mm mm 2 24kV 36kV mm 2 16-50 16-35 25-35 70-120 50-70 50-70 mm 2 2 =A 35-50 =B 150-240 95-240 95-185 300-500 300-400 240-400 15-185 =D 630-1000 500-800 500-630 240-500 =E 1000 70-120 800-1000 630-1000 =C =F Number of Cores Single Core =1 3-Core =3 Dielectric or Insulation Type XLPE =X Location of Installation Indoor =1 Outdoor =O Length of Termination Tail (3-Core only) for 450 mm =H1 for 650 mm =H2 for 800 mm =H3 for 1200 mm =H4 MEDIUM VOLTAGE CABLE ACCESSORIES Cable Cross Section Accessories Not include termination accessories such as cable lug, armour kit, ground connector, bolt & nut, earth braid. Ordering Example: APKT-17C 3X O-H3-T Outdoor termination for 12/17.5 kV, 120 mm 2 3-core XLPE cable, tail length 800 mm. Duyen Ha Power Equipment Co.,Ltd 3 R ayc he m te rm inatio n k it fo r X L P E c a ble w itho ut a rm o ur Voltage Cable Size Single Core (kV) (mm 2 ) Indoor Outdoor Indoor Outdoor 7.2 16 -50 A P K T 7A 1X I-H2-T A P K T 7A 1XO -H2-T A P K T 7A 3X I-H2-T A P K T 7A 3XO -H2-T 70 -120 A P K T 7B 1X I-H2-T A P K T 7B 1XO -H2-T A P K T 7B 3X I-H2-T A P K T 7B 3XO -H2-T 150 -24 0 A P K T 7C 1X I-H2-T A P K T 7C 1XO -H2-T A P K T 7C 3X I-H2-T A P K T 7C 3XO -H2-T 30 0 -50 0 A P K T 7D 1X I-H2-T A P K T 7D 1XO -H2-T A P K T 7D 3X I-H2-T A P K T 7D 3XO -H2-T 6 30 -10 0 0 A P K T 7E 1X I-H2-T A P K T 7E 1XO -H2-T - - 15-35 A P K T 17A 1X I-H2-T A P K T 17A 1XO -H2-T A P K T 17A 3X I-H2-T A P K T 17A 3XO -H2-T 50 -70 A P K T 17B 1X I-H2-T A P K T 17B 1XO -H2-T A P K T 17B 3X I-H2-T A P K T 17B 3XO -H2-T 9 5-24 0 A P K T 17C 1X I-H2-T A P K T 17C 1XO -H2-T A P K T 17C 3X I-H2-T A P K T 17C 3XO -H2-T 30 0 -4 0 0 A P K T 17D 1X I-H2-T A P K T 17D 1XO -H2-T A P K T 17D 3X I-H2-T A P K T 17D 3XO -H2-T 50 0 -8 0 0 A P K T 17E 1X I-H2-T A P K T 17E 1XO -H2-T - - 10 0 0 A P K T 17F 1X I-H2-T A P K T 17F 1XO -H2-T - - 25-35 A P K T 24 A 1X I-H3-T A P K T 24 A 1XO -H3-T A P K T 24 A 3X I-H3-T A P K T 24 A 3XO -H3-T 50 -70 A P K T 24 B 1X I-H3-T A P K T 24 B 1XO -H3-T A P K T 24 B 3X I-H3-T A P K T 24 B 3XO -H3-T 9 5-18 5 A P K T 24 C 1X I-H3-T A P K T 24 C 1XO -H3-T A P K T 24 C 3X I-H3-T A P K T 24 C 3XO -H3-T 24 0 -4 0 0 A P K T 24 D 1X I-H3-T A P K T 24 D 1XO -H3-T A P K T 24 D 3X I-H3-T A P K T 24 D 3XO -H3-T 50 0 -6 30 A P K T 24 E 1X I-H3-T A P K T 24 E 1XO -H3-T - - 8 0 0 -10 0 0 A P K T 24 F 1X I-H3-T A P K T 24 F 1XO -H3-T - - 35-50 A P K T 36 B 1X I-H3-T A P K T 36 B 1XO -H3-T A P K T 36 B 3X I-H3-T A P K T 36 B 3XO -H3-T 12-17.5 25-35 MEDIUM VOLTAGE CABLE ACCESSORIES 36 4 Three Core 70 -120 A P K T 36 C 1X I-H3-T A P K T 36 C 1XO -H3-T A P K T 36 C 3X I-H3-T A P K T 36 C 3XO -H3-T 150 -18 5 A P K T 36 D 1X I-H3-T A P K T 36 D 1XO -H3-T A P K T 36 D 3X I-H3-T A P K T 36 D 3XO -H3-T 24 0 -50 0 A P K T 36 E 1X I-H3-T A P K T 36 E 1XO -H3-T A P K T 36 E 3X I-H3-T A P K T 36 E 3XO -H3-T 6 30 -10 0 0 A P K T 36 F 1X I-H3-T A P K T 36 F 1XO -H3-T - - Note: For armoured cables, please contact your local sales representative Duyen Ha Power Equipment Co.,Ltd Heat-Shrink Terminations EPKT Terminations for polymeric and MIND paper insulated cables from 7.2 kV up to 36 kV General Description With millions of installations throughout the world, Raychem EPKT cable terminations for up to 36 kV are acknowledged to be more reliable and quicker to install than conventional systems. A pr oven system Consistent performance in extreme temperatures, atmospheric pollution and ultra-violet light has proven the insulating and sealing ability of Raychem terminations for more than 35 years. Features & Benefits Duyen Ha Power Equipment Co.,Ltd MEDIUM VOLTAGE CABLE ACCESSORIES • All applications for polymeric and MIND paper on 1-core, 3-core, armoured and unarmoured cables • Red non-tracking Raychem HVOT tubing provides excellent environmental protection • Can be used in combination with Raychem RICS / RCAB / RSRB • Enhanced range-taking ability means that one kit fits more conductor sizes,reducing stocking requirements • Unlimited shelf life allows stocking of economic quantities without product spoilage • Components are lightweight and non-shattering • Clear instruction sheets • Fully sealed against water ingress from the environment or from within the conductor strands • Compatible with all state of the art screen removal techniques • No tapering of insulation required • No polishing of polymeric insulation surface • Factory engineered kit permits rapid on-site installation • No mechanical stress at insulation screen cutback • Termination accommodates same bending radius as cable • Visual confirmation of correct assembly sequence possible after installation • Rain skirts can be installed to allow either top or bottom feed • No soldering of earthing accessories required • Unsurpassed performance in polluted environments, proven over three decades. 5 S e le c tio n Info rm atio n: d im e nsio ns show n in m illim e te rs XXXX P ro d uc t F a m ily - XX X X X X -X X XXX =EPKT Voltage up to 7.2 kV =7 12 and 17.5 kV =17 24 kV =24 36 kV =36 MEDIUM VOLTAGE CABLE ACCESSORIES C a ble c ro ss se c tio n 6 7.2 kV 12/17.5 kV 24 kV 36 kV mm 2 mm 2 mm 2 mm 2 16-50 16-35 70-120 35-70 25-50 150-240 95-240 70-185 50-95 =C 300-500 300-400 240-400 120-185 =D 630-1000 500-800 500-630 240-500 =E 1000 800-1000 630-1000 =F =A =B N um be r o f co re s Single Core =1 3-Core =3 D ie le c tric o r insulatio n ty pe Plastic =X MIND Paper =M L o c atio n o f insta llatio n Indoor =1 Outdoor =O L e ng th o f te rm inatio n ta il ( 3-C o re o nly ) for 450 mm =H1 for 650 mm =H2 for 800 mm =H3 for 1200 mm =H4 A cce sso rie s If needed add mod. codes to termination kit O rd e ring E xa m ple : EPKT-17C 3M O-H3 Outdoor Termination for 12/17.5 kV, 120 mm 2 3-Core Paper Cable, tail length 800 mm. Duyen Ha Power Equipment Co.,Ltd R ayc he m E P K T Te rm inatio n K it F o r X L P E C a ble W itho ut A rm o ur Cable Size (mm 2 ) 7.2 16 -50 70 -120 150 -24 0 30 0 -50 0 6 30 -10 0 0 15-35 50 -70 9 5-24 0 30 0 -4 0 0 50 0 -8 0 0 10 0 0 25-35 50 -70 9 5-18 5 24 0 -4 0 0 50 0 -6 30 8 0 0 -10 0 0 35-50 70 -120 150 -18 5 24 0 -50 0 6 30 -10 0 0 12/ 17.5 24 36 Singel Core Three Core Indoor Outdoor Indoor Outdoor E P K T 7A 1X I-H 2-T E P K T 7B 1X I-H 2-T E P K T 7C 1X I-H 2-T E P K T 7D 1X I-H 2-T E P K T 7E 1X I-H 2-T E P K T 17A 1X I-H 2-T E P K T 17B 1X I-H 2-T E P K T 17C 1X I-H 2-T E P K T 17D 1X I-H 2-T E P K T 17E 1X I-H 2-T E P K T 17F 1X I-H 2-T E P K T 24 A 1X I-H 2-T E P K T 24 B 1X I-H 2-T E P K T 24 C 1X I-H 2-T E P K T 24 D 1X I-H 2-T E P K T 24 E 1X I-H 2-T E P K T 24 F 1X I-H 2-T E P K T 36 B 1X I-H 2-T E P K T 36 C 1X I-H 2-T E P K T 36 D 1X I-H 2-T E P K T 36 E 1X I-H 2-T E P K T 36 F 1X I-H 2-T E P K T 7A 1XO -H 2-T E P K T 7B 1XO -H 2-T E P K T 7C 1XO -H 2-T E P K T 7D 1XO -H 2-T E P K T 7E 1XO -H 2-T E P K T 17A 1XO -H 2-T E P K T 17B 1XO -H 2-T E P K T 17C 1XO -H 2-T E P K T 17D 1XO -H 2-T E P K T 17E 1XO -H 2-T E P K T 17F 1XO -H 2-T E P K T 24 A 1XO -H 3-T E P K T 24 B 1XO -H 3-T E P K T 24 C 1XO -H 3-T E P K T 24 D 1XO -H 3-T E P K T 24 E 1XO -H 3-T E P K T 24 F 1XO -H 3-T E P K T 36 B 1XO -H 3-T E P K T 36 C 1XO -H 3-T E P K T 36 D 1XO -H 3-T E P K T 36 E 1XO -H 3-T E P K T 36 F 1XO -H 3-T E P K T 7A 3X I-H 2-T E P K T 7B 3X I-H 2-T E P K T 7C 3X I-H 2-T E P K T 7D 3X I-H 2-T E P K T 17A 3X I-H 2-T E P K T 17B 3X I-H 2-T E P K T 17C 3X I-H 2-T E P K T 17D 3X I-H 2-T E P K T 24 A 3X I-H 3-T E P K T 24 B 3X I-H 3-T E P K T 24 C 3X I-H 3-T E P K T 24 D 3X I-H 3-T E P K T 36 B 3X I-H 3-T E P K T 36 C 3X I-H 3-T E P K T 36 D 3X I-H 3-T E P K T 36 E 3X I-H 3-T - E P K T 7A 3XO -H 2-T E P K T 7B 3XO -H 2-T E P K T 7C 3XO -H 2-T E P K T 7D 3XO -H 2-T E P K T 17A 3XO -H 2-T E P K T 17B 3XO -H 2-T E P K T 17C 3XO -H 2-T E P K T 17D 3XO -H 2-T E P K T 24 A 3XO -H 3-T E P K T 24 B 3XO -H 3-T E P K T 24 C 3XO -H 3-T E P K T 24 D 3XO -H 3-T E P K T 36 B 3XO -H 3-T E P K T 36 C 3XO -H 3-T E P K T 36 D 3XO -H 3-T E P K T 36 E 3XO -H 3-T - Note: For armoured cables, please contact our local sales representative. Technical reports (Others information can be provided as request.) PPR-2920 Test report for MV termination EPKT in according with IEC60502 PPR-2375 Test report for MV termination EPKT in according with CENELEC HD629 PPR-1676 Type Approval Certificate of EPKT termination by DNV Duyen Ha Power Equipment Co.,Ltd MEDIUM VOLTAGE CABLE ACCESSORIES Voltage (kV) 7 Heat-Shrink Terminations IXSU-F/OXSU-F Heat-shrinkable termination system with non-linear, zinc oxide stress control for polymeric cables up to 24 kV General Description The Raychem IXSU/OXSU series comprises a one-piece termination incorporating the reliable red non-tracking environmental protection tube with a state of the art non -linear, zinc oxide based stress control material. The zinc oxide is dispersed in a mastic matrix and is co-extruded with the red non tracking tube. The mastic provides moisture seals at the top and bottom of the termination, making for a fully integrated, Class 1, one-piece termination. Indoor terminations require no rain sheds, making it ideal for application in confined spaces, especially in the ship building industry. Discrete rain sheds facilitate outdoor, inverted installations. MEDIUM VOLTAGE CABLE ACCESSORIES Features & Benefits 8 • All applications for polymeric 1-core, 3-core, armoured and unarmoured cables up to 24 kV • Electrical Stress control based on Raychem ceramic semi-conductor technology (nonlinear zinc oxide) providing unsurpassed electrical performance • The mastic based stress control is co-extruded with the proven red non-tracking Raychem HVOT tubing creating a one-piece termination. Mastic also provides a moisture seal at the ends of the termination. • Can be used in combination with Raychem RICS / RCAB / RSRB bushing boots • Enhanced range-taking ability means that one kit fits more conductor sizes, reducing stocking requirements • Unlimited shelf life allows stocking of economic quantities without product spoilage • Components are lightweight and non-shattering • Clear instruction sheets • Fully sealed against water ingress from the environment or from within the conductor strands • Superior AC and impulse voltage withstand capability facilitates very short, shed less terminations ideal for installation in confined spaces. • The integrated stress control mastic also provides a moisture seal, eliminating the need for separate, discrete seals, greatly simplifying installation • Compatible with all state of the art screen removal techniques • No tapering of insulation required • No polishing of polymeric insulation surface • Factory engineered kit permits rapid on-site installation • No mechanical stress at insulation screen cutback • Termination accommodates same bending radius as cable • Visual confirmation of correct assembly sequence possible after installation • Rain skirts can be installed to allow either top or bottom feed • No soldering of earthing accessories required • Unsurpassed performance in polluted environments, proven over three decades. • Compatible for use with mechanical and crimp connectors Duyen Ha Power Equipment Co.,Ltd S e le c tio n Info rm atio n: d im e nsio ns show n in m illim e te rs 12 k V Te rm inatio n fo r c rim p lug S c re e ne d sing le c o re pla stic a nd rubbe r c a ble Cross section (mm 2 ) Kit number Indoor Kit number Outdoor Diameter over insulation HD 620 A2 (mm) 10 – 35 25 – 9 5 9 5 – 24 0 24 0 – 50 0 50 0 – 8 0 0 8 0 0 – 120 0 IX S U -F 3111 IX S U -F 3121 IX S U -F 3131 IX S U -F 314 1 IX S U -F 3151 IX S U -F 316 1 O X S U -F 3111 O X S U -F 3121 O X S U -F 3131 O X S U -F 314 1 O X S U -F 3151 O X S U -F 316 1 16 .3 13.7 – 20 .8 18 .6 – 28 .4 25.7 – 36 .2 34 .0 – 4 2.2 39 .5 – 50 .0 Te rm inatio n w ith m e c ha nic a l lug B L MT S c re e ne d sing le c o re pla stic a nd rubbe r c a ble Cross section (mm 2 ) 25 – 9 5 9 5 – 24 0 120 – 30 0 18 5 – 4 0 0 50 0 – 6 30 12 k V Kit number Outdoor IX S U -F 3111-ML-1-13 IX S U -F 3111-ML-1-17 IX S U -F 3121-ML-1-13 IX S U -F 3121-ML-1-17 IX S U -F 3131-ML-4 -13 IX S U -F 3131-ML-4 -17 IX S U -F 3131-ML-5-13 IX S U -F 3131-ML-5-17 IX S U -F 314 1-ML-6 -13 IX S U -F 314 1-ML-6 -17 IX S U -F 3151-ML-7-17 IX S U -F 3151-ML-7-21 O X S U -F 3111-ML-1-13 O X S U -F 3111-ML-1-17 O X S U -F 3121-ML-1-13 O X S U -F 3121-ML-1-17 O X S U -F 3131-ML-4 -13 O X S U -F 3131-ML-4 -17 O X S U -F 3131-ML-5-13 O X S U -F 3131-ML-5-17 O X S U -F 314 1-ML-6 -13 O X S U -F 314 1-ML-6 -17 O X S U -F 3151-ML-7-17 O X S U -F 3151-ML-7-21 Diameter over insulation HD 620 A2 (mm) 13.7 – 16 .3 13.7 – 20 .8 18 .6 – 28 .4 20 .1 – 30 .4 23.2 – 33.6 34 .4 – 4 0 .0 Te rm inatio n fo r c rim p lug S c re e ne d 3 -c o re pla stic a nd rubbe r c a ble w itho ut a rm o ur Cross section (mm 2 ) 10 – 16 16 – 35 25 – 70 9 5 – 24 0 24 0 – 50 0 Tail Length (mm) Kit number Indoor Kit number Outdoor 4 50 120 0 4 50 120 0 4 50 120 0 4 50 120 0 4 50 120 0 IX S U -F 330 1 IX S U -F 330 4 IX S U -F 3311 IX S U -F 3314 IX S U -F 3321 IX S U -F 3324 IX S U -F 3331 IX S U -F 3334 IX S U -F 334 1 IX S U -F 334 4 O X S U -F 330 1 O X S U -F 330 4 O X S U -F 3311 O X S U -F 3314 O X S U -F 3321 O X S U -F 3324 O X S U -F 3331 O X S U -F 3334 O X S U -F 334 1 O X S U -F 334 4 Te rm inatio n w ith m e c ha nic a l lug B L MT S c re e ne d 3 -c o re pla stic a nd rubbe r c a ble w itho ut a rm o ur Cross section (mm 2 ) Tail Length (mm) 4 50 25 – 35 120 0 4 50 25 – 70 120 0 4 50 9 5 – 24 0 120 0 4 50 30 0 – 4 0 0 120 0 Duyen Ha Power Equipment Co.,Ltd Kit number Indoor Kit number Outdoor IX S U -F 3311-ML-1-13 IX S U -F 3311-ML-1-17 IX S U -F 3314 -ML-1-13 IX S U -F 3314 -ML-1-17 IX S U -F 3321-ML-1-13 IX S U -F 3321-ML-1-17 IX S U -F 3324 -ML-1-13 IX S U -F 3324 -ML-1-17 IX S U -F 3331-ML-4 -13 IX S U-F 3331-ML-4 -17 IX S U -F 3334 -ML-4 -13 IX S U -F 3334 -ML-4 -17 IX S U -F 334 1-ML-6 -13 IX S U -F 334 1-ML-6 -17 IX S U -F 334 1-ML-6 -21 IX S U -F 334 4 -ML-6 -13 IX S U -F 334 4 -ML-6 -17 IX S U -F 334 4 -ML-6 -21 O X S U -F 3311-ML-1-13 O X S U -F 3311-ML-1-17 O X S U -F 3314 -ML-1-13 O X S U -F 3314 -ML-1-17 O X S U -F 3321-ML-1-13 O X S U -F 3321-ML-1-17 O X S U -F 3324 -ML-1-13 O X S U -F 3324 -ML-1-17 O X S U -F 3331-ML-4 -13 O X S U -F 3331-ML-4 -17 O X S U -F 3334 -ML-4 -13 O X S U -F 3334 -ML-4 -17 O X S U -F 334 1-ML-6 -13 O X S U -F 334 1-ML-6 -17 O X S U -F 334 1-ML-6 -21 O X S U -F 334 4 -ML-6 -13 O X S U -F 334 4 -ML-6 -17 O X S U -F 334 4 -ML-6 -21 MEDIUM VOLTAGE CABLE ACCESSORIES 25 – 35 Kit number Indoor 9 24 k V Te rm inatio n fo r c rim p lug S c re e ne d sing le co re pla stic a nd rubbe r c a ble Cross section (mm 2 ) Kit number Indoor Kit number Outdoor Diameter over insulation HD 620 A2 (mm) 25 – 70 70 – 24 0 18 5 – 4 0 0 4 0 0 – 80 0 10 0 0 – 120 0 IX S U -F 5121 IX S U -F 5131 IX S U -F 514 1 IX S U -F 5151 IX S U -F 516 1 O X S U -F 5121 O X S U -F 5131 O X S U -F 514 1 O X S U -F 5151 O X S U -F 516 1 17.9 – 23.4 21.9 – 32.6 27.4 – 37.8 35.1 – 4 6 .9 4 9 .4 – 56 .0 Te rm inatio n w ith m e c ha nic a l lug B L MT S c re e ne d sing le co re pla stic a nd rubbe r c a ble Cross section (mm 2 ) 25 – 9 5 9 5 – 24 0 120 – 30 0 18 5 – 4 0 0 MEDIUM VOLTAGE CABLE ACCESSORIES 50 0 – 6 30 10 24 k V Kit number Indoor Kit number Outdoor IX S U -F 5121-ML-1-13 IX S U -F 5121-ML-1-17 IX S U -F 5131-ML-4 -13 IX S U -F 5131-ML-4 -17 IX S U -F 5131-ML-5-13 IX S U -F 5131-ML-5-17 IX S U -F 514 1-ML-6 -13 IX S U -F 514 1-ML-6 -17 IX S U -F 514 1-ML-6 -21 IX S U -F 5151-ML-7-17 IX S U -F 5151-ML-7-21 O X S U -F 5121-ML-1-13 O X S U -F 5121-ML-1-17 O X S U -F 5131-ML-4 -13 O X S U -F 5131-ML-4 -17 O X S U -F 5131-ML-5-13 O X S U -F 5131-ML-5-17 O X S U -F 514 1-ML-6 -13 O X S U -F 514 1-ML-6 -17 O X S U -F 514 1-ML-6 -21 O X S U -F 5151-ML-7-17 O X S U -F 5151-ML-7-21 Diameter over insulation HD 620 A2 (mm) 17.9 – 25.0 23.0 – 32.6 24 .3 – 34 .6 27.4 – 37.8 37.9 – 4 4 .0 Te rm inatio n fo r c rim p lug S c re e ne d 3-co re pla stic a nd rubbe r c a ble w itho ut a rm o ur Cross section (mm 2 ) 10 – 25 25 – 50 70 – 18 5 18 5 – 4 0 0 Tail Length (mm) Kit number Indoor Kit number Outdoor 4 50 120 0 4 50 120 0 4 50 120 0 4 50 120 0 IX S U -F 5311 IX S U -F 5314 IX S U -F 5321 IX S U -F 5324 IX S U -F 5331 IX S U -F 5334 IX S U -F 534 1 IX S U -F 534 4 O X S U -F 5311 O X S U -F 5314 O X S U -F 5321 O X S U -F 5324 O X S U -F 5331 O X S U -F 5334 O X S U -F 534 1 O X S U -F 534 4 Te rm inatio n w ith m e c ha nic a l lug B L MT S c re e ne d 3-co re pla stic a nd rubbe r c a ble w itho ut a rm o ur Cross-section (mm 2 ) Tail Length (mm) 4 50 25 – 50 120 0 4 50 9 5 – 18 5 120 0 4 50 18 5 – 4 0 0 120 0 Kit number Indoor Kit number Outdoor IX S U -F 5321-ML-1-13 IX S U -F 5321-ML-1-17 IX S U -F 5324 -ML-1-13 IX S U -F 5324 -ML-1-17 IX S U -F 5331-ML-4 -13 IX S U -F 5331-ML-4 -17 IX S U -F 5334 -ML-4 -13 IX S U -F 5334 -ML-4 -17 IX S U -F 534 1-ML-6 -13 IX S U -F 534 1-ML-6 -17 IX S U -F 534 1-ML-6 -21 IX S U -F 534 4 -ML-6 -13 IX S U -F 534 4 -ML-6 -17 IX S U -F 534 4 -ML-6 -21 O X S U -F 5321-ML-1-13 O X S U -F 5321-ML-1-17 O X S U -F 5324 -ML-1-13 O X S U -F 5324 -ML-1-17 O X S U -F 5331-ML-4 -13 O X S U -F 5331-ML-4 -17 O X S U -F 5334 -ML-4 -13 O X S U -F 5334 -ML-4 -17 O X S U -F 534 1-ML-6 -13 O X S U -F 534 1-ML-6 -17 O X S U -F 534 1-ML-6 -21 O X S U -F 534 4 -ML-6 -13 O X S U -F 534 4 -ML-6 -17 O X S U -F 534 4 -ML-6 -21 Duyen Ha Power Equipment Co.,Ltd Medium Voltage Heat-Shrinkable Joints EPKJ Joints for screened plastic and rubber insulated cables up to 36 kV General Description Raychem EPKJ series of heat shrinkable joints is based on well established, highly reliable, radiation cross linked polymeric tubes which are easy to install, eliminates shelf life limitations even in severe climates and permits immediate back filling of trenches and quick energization. Features & Benefits Selection Information: dimensions shown in millimeters 3-Core Polymeric Cable (Unarmoured) EPKJ-R Inline Joints Size of Conductor in [mm2 ] Connector Dia. max. [mm] Connector Length max. [mm] Kit Number Unarmoured 35-70 22 110 EPKJ-17A/3XU-3XU 95-185 29 140 EPKJ-17B/3XU-3XU 240-400 42 180 EPKJ-17C/3XU-3XU 12 kV 24 kV 500-630 36 kV 52 200 EPKJ-17D/3XU-3XU 25 20 110 EPKJ-24A/3XU-3XU 35-70 25 140 EPKJ-24B/3XU-3XU 95-240 36 160 EPKJ-24C/3XU-3XU 300-400 44 200 EPKJ-24D/3XU-3XU Duyen Ha Power Equipment Co.,Ltd MEDIUM VOLTAGE CABLE ACCESSORIES • Polymeric/elastomeric triple extruded, conducting/insulating joint body ensures higher recovery force and fewer components, improving reliability and simplifying installation. • Insulating, screening and electric field control derived from specially formulated, crosslinked polymeric materials with precisely defined electrical characteristics. • Factory engineered components ensure consistent installations with pre-determined insulation thickness, eliminating installer errors. • No penciling of insulation required, reducing installation time. • Shrinking process drives out moisture / condensation in the jointing area, ensuring no moisture entrapment within the joint. • Special low viscosity void filler flows and uniformly envelops the connector, creating a smooth profile. • Wide use range of kits ensures fewer kits to cover a range of conductor sizes, reducing inventory. 11 3-Core Polymeric Cable (Tape Armour) EPKJ-R Inline Joints Size of Conductor in [mm2 ] 12 kV 24 kV 36 kV Kit Number Tape Armour 35-70 E P K J -17A / 3X U -3X U -T 9 5-18 5 E P K J -17B / 3X U -3X U -T 24 0 -4 0 0 E P K J -17C / 3X U -3X U -T 25 E P K J -24 A / 3X U -3X U -T 35-70 E P K J -24 B / 3X U -3X U -T 9 5-24 0 E P K J -24 C / 3X U -3X U -T 30 0 -4 0 0 E P K J -24 D/ 3X U -3X U -T EPKJ-R Inline Joints Single Core Polymeric Cable Size of Conductor in [mm2 ] 12 kV 24 kV 36 kV 35-70 E P K J -17A / 1X U -1X U 9 5-18 5 E P K J -17B / 1X U -1X U 24 0 -4 0 0 E P K J -17C / 1X U -1X U MEDIUM VOLTAGE CABLE ACCESSORIES 50 0 -6 30 12 Kit Number unarmoured E P K J -17D/ 1X U -1X U 25 E P K J -24 A / 1X U -1X U 35-70 E P K J -24 B / 1X U -1X U 9 5-24 0 E P K J -24 C / 1X U -1X U 30 0 -4 0 0 E P K J -24 D/ 1X U -1X U 50 -70 E P K J -36 A / 1X U -1X U 9 5-150 E P K J -36 B / 1X U -1X U 18 5-4 0 0 E P K J -36 C / 1X U -1X U 50 0 -6 30 E P K J -36 D/ 1X U -1X U Duyen Ha Power Equipment Co.,Ltd Heat-Shrink Joints MXSU/MXST/MXSW/MXAW Jointing system up to 36 kV complete with mechanical connectors General Description Raychem MXSU/MXST/MXSW/MXAW series of heat shrinkable cable joints have been specifically designed for use with mechanical connectors. The inclusion of range taking connectors ensures the kits can be supplied complete, with connectors that cover the use range of the kits. MXSU/MXST/MXSW/MXAW kits exceed international performance standards including CENELEC HD 629 and IEC 60502-4. Tested for 800 hours of heat cycling at a conductor temperature of 130˚C @ 2.5U0 . Features & Benefits Selection Information: dimensions shown in millimeters Inline joint for 3 core poly cables with copper wire shield, without armour Mechanical Connectors included MXSU-3311 MXSU-3321 MXSU-3331 MXSU-3332 MXSU-5311 MXSU-5321 MXSU-5331 MXSU-5332 12 kV 24 kV 25-95 70-150 95-240 150-300 25-95 50-150 95-240 150-300 Diameter Conductor Diameter over Core insulation Diameter Cable Over sheath 5.2-12.0mm 8.7-15.0mm 10.3-19.2mm 12.9-21.6mm 5.2-12.0mm 7.2-15.0mm 10.3-19.2mm 12.9-21.6mm 13.2-21.8mm 17.6-24.3mm 18.5-29.4mm 21.6-31.4mm 17.9-26.0mm 20.2-29.5mm 23.0-33.6mm 25.0-35.5mm 40-61mm 45-68mm 53-77mm 59-85mm 48-72mm 55-80mm 62-89mm 70-96mm Diameter Conductor Diameter over Core insulation Diameter Cable Over sheath 10.3-19.2mm 12.9-21.6mm 10.3-19.2mm 12.9-21.6mm 17.6-29.4mm 22.0-31.4mm 23.0-33.6mm 25.0-35.5mm 60-80mm 64-85mm 70-90mm 76-95mm Diameter Conductor Diameter over Core insulation Diameter Cable Over sheath 10.3-19.2mm 12.9-21.6mm 10.3-19.2mm 12.9-21.6mm 17.6-29.4mm 22.0-31.4mm 23.0-33.6mm 25.0-35.5mm 60-80mm 64-85mm 70-90mm 76-95mm Inline joint for 3 core poly cables with copper wire shield, and steel tape armour Mechanical Connectors included MXST-3331 MXST-3332 MXST-5331 MXST-5332 12 kV 24 kV 95-240 150-300 95-240 150-300 Inline joint for 3 core poly cables with copper tape shield and steel wire armour Mechanical Connectors included MXSW-3331 MXSW-3332 MXSW-5331 MXSW-5332 12 kV 24 kV 95-240 150-300 95-240 150-300 MEDIUM VOLTAGE CABLE ACCESSORIES • Polymeric/elastomeric triple extruded, conducting/insulating joint body ensures higher recovery force and fewer components, improving reliability and simplifying installation. • Range taking capability of mechanical connectors makes it possible to include a single connector that covers the use range of the kit. • Mechanical connectors eliminate the need for a crimping tool. • Shear head bolts, with a pre-set shear torque, ensure consistent contact pressure. Specially designed contact surface at the bolt tip breaks up the conductor oxide layer resulting in an excellent electrical contact and improved tensile strength. Eliminates jointer errors. • Tin plated mechanical connectors with corrosion inhibiting compound facilitates installation on aluminium or copper conductors. • Can withstand sheath testing for 15 minutes at 15kV DC and 8kV AC. • Range taking kits with unlimited shelf life. Note: For any other cable construction, please contact your local sales representative Duyen Ha Power Equipment Co.,Ltd 13 Inline joint for 1 core poly cables with copper wire shield without armour Mechanical Connectors included MXSU-3111 MXSU-3121 MXSU-3131 MXSU-3132 MXSU-3141 MXSU-3151 MXSU-3161 MXSU-3171 MXSU-3181 MXSU-5101 MXSU-5111 MXSU-5121 MXSU-5131 MXSU-5132 MXSU-5141 MXSU-5151 MXSU-5161 MXSU-5171 MXSU-5181 MXSU-6111 MXSU-6121 MXSU-6131 MXSU-6141 MXSU-6151 MXSU-6161 MXSU-6171 MXS U-61 81 12 kV 24 kV 36 kV 25-95 70-150 95-240 150-300 240-400 500 630 800 1000 10-35 25-95 50-150 95-240 150-300 240-400 500 630 80 0 1000 35-95 70-150 150-300 240-400 500 630 800 1000 Diameter Conductor 5.2-12.0 mm 8.7-15.0 mm 10.3-19.2 mm 12.9-21.6 mm 17.8-24.6 mm 25.5-27.6 mm 29.0-32.5 mm 32.0-33.8 mm 38.5-39.2 mm 3.7-7.5 mm 5.2-12.0 mm 7.2-15.0 mm 10.3-19.2 mm 12.9-21.6 mm 17.8-24.6 mm 25.5-27.6 mm 29.0-32.5 mm 32.0-33.8 mm 38.5-39.2 mm 6.0-12.0 mm 8.7-15.0 mm 13.9-21.6 mm 17.8-24.6 mm 25.5-29.2 mm 29.0-32.5 mm 32.0-33.8 mm 38.5-39.2 mm Diameter over Core insulation 13.2-21.8 mm 17.6-24.3 mm 17.6-29.4 mm 21.6-30.4 mm 25.7-32.6 mm 33.8-37.2 mm 37.5-40.0 mm 39.5-42.6 mm 4 5.0-47.6 mm 15.0-22.0 mm 17.9-26.0 mm 20.2-29.5 mm 23.0-33.6 mm 25.0-35.5 mm 29.9-38.8 mm 37.2-41.6 mm 39.2-44.7 mm 44.8-46.9 mm 49.4-53.2 mm 24.0-30.0 mm 26.2-34.5 mm 31.1-39.6 mm 36.2-42.8 mm 40.1-46.6 mm 45.8-50.5 mm 50.1-53.4 mm 55.7-58.8 mm Diameter Cable Over sheath 23-32 mm 25-38 mm 26-40 mm 29-43 mm 33-47 mm 44-50 mm 47-54 mm 52-57 mm 59-64 mm 17-33 mm 25-38 mm 28-38 mm 30-43 mm 33-48 mm 35-49 mm 48-54 mm 50-58 mm 58-61 mm 64-67 mm 32-43 mm 34-44 mm 38-53 mm 40-54 mm 52-60 mm 55-68 mm 62-66 mm 69-73 mm MEDIUM VOLTAGE CABLE ACCESSORIES Note: For armoured and tape shield cables, please contact your local sales representative 14 Inline joint for 1 core poly cables with copper wire or tape shield with aluminium wire armour Mechanical Connectors included 24 kV Diameter Conductor Diameter over Core insulation Diameter Cable Over sheath MXAW-5131 MXAW-5132 MXAW-5141 MXAW-5151 MXAW-5161 95-185 150-300 240-400 500 630 10.3-17.6 mm 12.9-21.6 mm 17.8-24.6 mm 25.5-27.6 mm 29.0-32.5 mm 23.0-31.2 mm 25.8-34.6 mm 29.4-38.8 mm 37.2-41.6 mm 39.2-44.7 mm 37-43 mm 40-48 mm 44-54 mm 48-56 mm 50-60 mm Note: For cable constructions or voltages not listed, please contact your local sales representative Duyen Ha Power Equipment Co.,Ltd Heat-Shrink Joints SXSU/SXST/SXSW/SXAW Joints for polymeric insulated cables from 12 kV up to 36 kV General Description Raychem SXSU/SXST/SXSW/SXAW series of heat shrinkable joints is based on well established, highly reliable, radiation cross linked polymeric tubes which are easy to install, eliminates shelf life limitations even in severe climates and permits immediate back filling of trenches and quick energization. With millions of installations throughout the world, Raychem SXSU cable joints for up to 36 kV are acknowledged to be more reliable and quicker to install than conventional systems. S XSU kits exceed International performance standards including CENELEC HD 629 and IEC 60502-4. Features & Benefits Selection Information: dimensions shown in millimeters Inline joint for 1-core polymeric cables with copper wire shield, without armour Kit Number 12kV SXSU-3111 SXSU-3121 SXSU-3131 SXSU-3141 SXSU-4111 SXSU-4121 SXSU-4131 SXSU-4141 SX SU-41 51 SXSU-5121 SXSU-5131 SXSU-5141 SXSU-5151 SXSU-5161 SXSU-6121 SXSU-6131 SXSU-6141 SXSU-6151 SXSU-6161 SXSU-6122 SXSU-6132 SXSU-6142 SXSU-6152 35-70 95-185 185-300 300-500 50-70 95-185 185-300 400-630 800-1200 24kV 36kV 25-95 95-240 240-500 630-800 1000-1200 35-95 95-150 185-4 00 500-800 800-1200 35-150 150-300 400-630 800-1200 Diameter over Core insulation 15,4-20,2 mm 17,6-26,9 mm 22,0-31,4 mm 28,4-38,8 mm 15,4-20,2 mm 17,6-26,9 mm 23,2-31,4 mm 29,8-42,5 mm 39,4-50,0 mm 17,6-26,0 mm 23,2-33,6 mm 29,8-41,6 mm 39,4-48,0 mm 49,4-56,2 mm 24,0-31,4 mm 26,4-34,4 mm 3 1,9-43,7 mm 42,9-53,4 mm 46,2-61,5 mm 24,0-34,4 mm 30,8-40,5 mm 40,1-50,5 mm 45,6-61,5 mm Diameter Cable oversheath 23-29 mm 25-37 mm 29-43 mm 36-52 mm 23-29 mm 25-37 mm 29-43 mm 40-52 mm 48-66 mm 25-37 mm 28-44 mm 33-52 mm 48-66 mm 55-75 mm 32-41 mm 35-46 mm 40-54 mm 55-66 mm 55-73 mm 33-44 mm 36-52 mm 40-62 mm 55-76 mm Connector dimensions max. diameter/max.length 23 mm/ 110 mm 29 mm/ 160 mm 34 mm/ 180 mm 44 mm/ 220 mm 22 mm/ 110 mm 29 mm/ 160 mm 36 mm/ 180 mm 52 mm/ 250 mm 62mm/ 280 mm 23 mm/ 120 mm 34 mm/ 140 mm 44 mm/ 230 mm 58 mm/ 250 mm 62 mm/ 280 mm 22 mm/ 140 mm 29 mm/ 160 mm 42 mm/ 220 mm 58 mm/ 250 mm 62 mm/ 280 mm 29 mm/ 160 mm 38 mm/ 160 mm 52 mm/ 250 mm 62 mm/ 280 mm MEDIUM VOLTAGE CABLE ACCESSORIES • Polymeric/elastomeric triple extruded, conducting/insulating joint body ensures higher recovery force and fewer components, improving reliability and simplifying installation. • Insulating, screening and electric field control derived from specially formulated, crosslinked polymeric materials with precisely defined electrical characteristics. • F actory engineered components ensure consistent installations with pre-determined insulation thickness, eliminating installer errors. • No penciling of insulation required, reducing installation time. • Shrinking pr ocess drives out moisture / condensation in the jointing area, ensuring no moisture entrapment within the joint. • Wide use range of kits ensures fewer kits to cover a range of conductor sizes, reducing inventory. • Special low viscosity void filler flows and uniformly envelops the connector, creating a smooth profile. • Unlimit ed shelf life allows stocking of economic quantities without product spoilage. • Enhanced range-taking ability means that one kit fits more conductor sizes,reducing stocking requirements. Note: For copper tape shield or armoured cables, please contact your local sales representative. Duyen Ha Power Equipment Co.,Ltd 15 Inline joint for 3-core polymeric cables with copper wire shield, without armour Kit Number 12kV SXSU-3311 SXSU-3321 SXSU-3331 SXSU-4302 SXSU-4312 SXSU-4322 SXSU-4332 SXSU-5322 SXSU-5 332 SXSU-5342 35-70 95-185 185-300 16-35 50-70 95-185 185-300 24kV Diameter over Core insulation 36kV 15,4-20,2 mm 17,6-26,9 mm 22,0-31,4 mm 13,2-17,3 mm 15,4-20,2 mm 17,6-26,9 mm 23,2-31,4 mm 17,6-26,0 mm 23,2-33,6 mm 29,8-41,6 mm 25-95 95 -240 240-500 Diameter Cable oversheath 40-57 mm 53-73 mm 63-82 mm 38-49 mm 46-57 mm 53-73 mm 63-82 mm 48-72 mm 62-89 mm 78-100 mm Connector dimensions max. diameter/max.length 23 mm/ 110 mm 29 mm/ 160 mm 34 mm/ 180 mm 17 mm/ 100 mm 22 mm/ 110 mm 29 mm/ 160 mm 36 mm/ 180 mm 23 mm/ 120 mm 34 mm/ 140 mm 44 mm/ 230 mm Note: For copper tape shield or armoured cables, please contact your local sales representative. Inline joint for 3-core polymeric cables with copper wire shield and steel tape armour Kit Number 12kV Diameter over Core insulation SXST-4303 SXST-4313 SXST-4323 SXST-4333 16-35 50-70 95-185 185-300 13,2-17,3 mm 15,4-20,2 mm 17,6-26,9 mm 23,2-31,4 mm Diameter Cable oversheath 38-52 mm 48-57 mm 56-73 mm 68-84 mm Connector dimensions max. diameter/max.length 17 mm/ 100 mm 22 mm/ 110 mm 29 mm/ 160 mm 36 mm/ 180 mm Note: For tape shield cables, please contact your local sales representative. MEDIUM VOLTAGE CABLE ACCESSORIES Inline joint for 3-core polymeric cables with copper wire shield and steel wire armour 16 Kit Number 12kV Diameter over Core insulation SXSW-4304 SXSW-4314 SXSW-4324 SXSW-4334 16-35 50-70 95-185 185-300 13,2-17,3 mm 15,4-20,2 mm 17,6-26,9 mm 23,2-31,4 mm Diameter Cable oversheath 38-54 mm 48-60 mm 56-75 mm 68-86 mm Connector dimensions max. diameter/max.length 17 mm/ 100 mm 22 mm/ 110 mm 29 mm/ 160 mm 36 mm/ 180 mm Note: For copper tape shield cables, please contact your local sales representative. Inline joint for 1-core polymeric cables with aluminium wire armour Kit Number 12kV SXAW-3121 SXAW-3131 SXAW-3141 SXAW-3151 SXAW-5121 SXAW-5131 SXAW-5141 SXAW-5151 SXAW- 6122 SXAW-6132 SXAW-6142 95-185 185-300 400-500 630-800 24kV Diameter over Core insulation 36kV 50-95 120-185 240-400 500-630 50-95 120-240 300-630 17,6-26,9 mm 22,0-31,4 mm 28,4-38,8 mm 39,4-45,5 mm 17,6-26,0 mm 23,2-33,6 mm 29,8-38,8 mm 39,4-45,0 mm 24,0-31,4 mm 30,8-40,5 mm 40,1-50,5 mm Diameter Cable oversheath 28-39 mm 33-45 mm 40-52 mm 53-59 mm 28-39 mm 33-44 mm 40-54 mm 54-64 mm 33-44 mm 44-54 mm 54-68 mm Connector dimensions max. diameter/max.length 28,5 mm/ 140 mm 34 mm/ 180 mm 44 mm/ 220 mm 58 mm/ 250 mm 23 mm/ 120 mm 28,5 mm/ 140 mm 38,5 mm/ 220 mm 52 mm/ 250 mm 23 mm/ 120 mm 32 mm/ 160 mm 52 mm/ 250 mm Note: For tape shield cables, please contact your local sales representative. Duyen Ha Power Equipment Co.,Ltd Bushing boot RICS insulated adapter termination system for SF6-insulated switchgear up to 24 kV General Description This insulated adapter provides perfect sealing, electrical insulation and an electrical connection between all Raychem terminations and SF6-insulated switchgear up to 24 kV. It is designed to fit bushing profiles according to EN 50181 type C. Raychem elastomeric RICS adapters are moulded parts which fit over the connection between the cable lug and the right-angled bushing of a gas insulated switchgear, where the air clearances are insufficient for normal operation. The non-tracking elastomeric housing has excellent track and erosion resistance, dielectric properties and environmental resistance, giving superb performance in areas of high humidity and electrical stress. Features & Benefits S e le c tio n Info rm atio n: d im e nsio ns show n in m illim e te rs R IC S -3133 T-A d a pte r up to 12 k V The insulating body, fixing bolts, terminal stud and cap are supplied in a 3-phase set complete with installation instruction. Cable terminations with lugs for M16 studs have to be ordered separately. Covers a wide cross section range of 70~300 sqmm. Tested according to CENELEC HD 629.1 S2:2006 , including tests like AC, DC (60 kV), BIL(95 kV), long-term loadcycling at AC voltage 16 kV phase-ground (2.5 Uo). Cross section (sqmm) Ordering description T-Adapter Termination for polymeric cables incl. Mechanical lugs 70 ~ 150 9 5 ~ 24 0 120 ~ 30 0 R IC S -3133 R IC S -3133 R IC S -3133 IX S U -F 3131-ML-2-17 IX S U -F 3131-ML-4 -17 IX S U -F 3131-ML-5-17 Duyen Ha Power Equipment Co.,Ltd MEDIUM VOLTAGE CABLE ACCESSORIES • Quick and easy to install. Works in combination with all Raychem termination product lines. • Can easily be removed and reinstalled without the need for additional material or tooling, allowing access to the bushing connection for test purposes. • The compact design of the adapters and their clear cut profiles simplify installation. The electrical connection with the aid of a stud renders additional fastening systems unnecessary. • The adapters are water-tight and guarantee uninterrupted operation, even under extreme environmental conditions with severe pollution. • Caters for a wide range of cables with as few fittings as possible, while optimising the product line for specific applications, thereby maximising reliability. • The adapters conform to CENELEC HD 629.1 S2:2006, IEC 540, VDE 0278 and ANSI IEEE 386 specifications. 17 R IC S T-a d a pte r w ith o r w itho ut surg e a rre ste r up to 24 k V Thick walled insulator made of high quality elastomer with sealing face over the termination, bushing cone and plug. The electrical connection is made with a terminal stud and the cable lug of the termination. Two cable connection is possible. A special plug which allows cable testing without disconnecting the adapter is also offered. The design of the adapter for connecting the surge arrester is basically identical. The elastomer insulator has an additional lead-in duct for the surge arrester. MEDIUM VOLTAGE CABLE ACCESSORIES Scope of supply (for three phases) Insulator, plug, terminal stud, small accessories and installation instructions. 18 T-adapter for perpendic ular connec tion of the term ination to S F 6 -insulated sw itc hgear T-adapter fitted w ith testing plug T-adapter for perpendic ular connec tion of term ination and surge arrester to S F 6 -insulated sw itc hgear S traight adapter for vertic al connec tion of the term ination to S F 6 -insulated sw itc hgear R IC S S tra ig ht a d a pte r up to 24 k V A thick walled, heat-shrinkable insulating sleeve provides a hermetic seal over the cone of the bushing and the termination. The adapter area is smoothed with a meltable filler strip. Scope of supply (for three phases) Heat-shrinkable insulating sleeving, filler strip, small accessories and installation instructions. Terminal stud and lug must be enclosed. R e late d te st re po rt Reference No. Voltage (kV) Specification P P R -250 5 P P R -250 9 P P R -110 6 12 12 24 HD 6 29 .1 S 2:20 0 6 HD 6 29 .1 S 2:20 0 6 / G O S T 1378 .0 -8 6 IE C 54 0 , V D E 0 278 and A N S I IE E E 38 6 Duyen Ha Power Equipment Co.,Ltd Bushing boot RSRB Heat shrinkable insulating bushing boots up to 36 kV General Description RSRB polymeric insulating boots are moulded parts which fit over the connection between the cable lug and equipment bushing to improve phase-to-phase and phaseto-ground insulation. They are used in switchgear and transformer cable boxes where air clearances are insufficient for normal operation, or to protect against flashover due to rodents or high humidity. The non-tracking polymeric housing has excellent erosion resistance, dielectric properties and environmental resistance, giving superb performance in areas of high humidity and electrical stress. The boot is coated internally with a hot melt adhesive to provide an excellent seal and improve electrical performance. RSRB boots work in combination with all Raychem heat shrink termination products. RSRB boots are quick and easy to install and do not require any taping of the bushing or the termination for voltages upto 24 kV. The boot can be easily removed, allowing access to the bushing connection for test purposes. • • • • • • • • Simple and easy installation Requires standard gas torch installation High-performance insulation material Excellent track and erosion resistance Removable for access to bushing connection Available for in-line and right angled configurations Unlimited shelf life Connection can be energised immediately after installation. S e le c tio n Info rm atio n: d im e nsio ns show n in m illim e te rs 11 k V B ushing B o o ts H e at-S hrink a ble Part Number In-Line Part Number Right Angle Conductor Size Range Paper (sqmm) Conductor Size Range XLPE (sqmm) R S R B 4 0 22 R S R B 4 0 24 R S R B 4 0 26 RSRB 40 42 RSRB 40 44 RSRB 40 46 16 ~35 50 ~9 5 120 ~30 0 16 ~9 5 120 ~30 0 Sold as set of three 2 2 k V R ig ht A ng le B ushing B o o ts H e at-S hrink a ble Part Number Conductor Size Range (sqmm) R S R B 50 4 4 R S R B 50 4 6 25~9 5 9 5~30 0 MEDIUM VOLTAGE CABLE ACCESSORIES Features & Benefits Sold as set of three Duyen Ha Power Equipment Co.,Ltd 19 33 k V R ig ht A ng le B ushing B o o ts He at-S hrink a ble Part Number Conductor Size Range (sqmm) R SR B 60 46 120 ~30 0 Sold as set of three R e late d te st re po rt Voltage (kV) P P R -0 6 20 P P R -0 6 21 P P R -0 6 9 1 P P R -10 8 9 17.5 17.5 36 24 MEDIUM VOLTAGE CABLE ACCESSORIES Reference No. 20 Duyen Ha Power Equipment Co.,Ltd Cold-Applied Joints CSJT Silicone cold-shrink joint with integrated stress control for XLPE cables up to 36 kV General Description Raychem CSJT Series of cold shrink joint offers a reliable, fast and easy to install jointing system is maintain a highly reliable network. A silicone rubber joint body with integrated geometrical stress cone and faraday cage provides excellent electrical stress control. CSJT kit are designed to cover a wide range of applications covering all available types of armouring and cable screens standand kit are supplied with a resin injected rejacketing system. Alternate heat shrink and cold shrink re-jacketing system is available upon required. Features & Benefits S e le c tio n Info rm atio n: d im e nsio ns show n in m illim e te rs 12 k V 3 -C o re c a ble Cross-section (mm2 ) Kit description Diameter over insulation(mm) Comment 50 ~70 9 5~18 5 24 0 ~30 0 C S J T-12-50 70 -T C S J T-12-9 518 -T C S J T-12-24 30 -T 16 ~21 21~26 26 ~32 Tape shielded, unarm oured Tape shielded, unarm oured Tape shielded, unarm oured Cross-section (mm2 ) Kit description Diameter over insulation(mm) Comment 50 ~70 9 5~18 5 24 0 ~30 0 400 50 0 C S J T-12-50 70 -T-S C C S J T-12-9 518 -T-S C C S J T-12-24 30 -T-S C C S J T-12-4 0 0 -T-S C C S J T-12-50 0 -T-S C 16 ~21 21~26 26 ~32 27~35 33~4 0 Tape shielded, unarm oured Tape shielded, unarm oured Tape shielded, unarm oured Tape shielded, unarm oured Tape shielded, unarm oured Cross-section (mm2 ) Kit description Diameter over insulation(mm) Comment 70 ~120 150 ~24 0 30 0 C S J T-24 -70 12-T C S J T-24 -1524 -T C S J T-24 -30 0 -T 21~26 26 ~32 27~35 Tape shielded, unarm oured Tape shielded, unarm oured Tape shielded, unarm oured Cross-section (mm2 ) Kit description Diameter over insulation(mm) Comment 70 ~120 150 ~24 0 30 0 400 C S J T-24 -70 12-T-S C C S J T-24 -1524 -T-S C C S J T-24 -30 0 -T-S C C S J T-24 -4 0 0 -T-S C 21~26 26 ~32 27~35 33~4 0 Tape shielded, unarm oured Tape shielded, unarm oured Tape shielded, unarm oured Tape shielded, unarm oured 12 k V 1-C o re c a ble 24 k V 3 -C o re c a ble 24 k V 1-C o re c a ble MEDIUM VOLTAGE CABLE ACCESSORIES • Pre-expanded, single piece silicone rubber joint body with high mechanical expansion capability allows a wide application range • Electrical stress control of the screen cut area by integrated conductive geometrical stress cones • Electrical stress control of the connector area by an integrated screened connection area (Faraday cage) • Proven shield continuity concept • The tape and resin outer sealing and protection system provides a reliable moisture seal, corrosion prevention and effective impact resistance • CSJT joints can be supplied with compression connectors or Raychem mechanical BSM connectors • CSJT joints can be modified for different armour types and/or wire shield cables. • CSJT joints can be applied with alternate rejacketing system • Pre-expansion on a easy-to-install spiral holdout system • CENELEC HD 629.1, requirements which include IEC and IEC60 The application range given in the table is based on polymeric insulated cable according to IEC 60502 standard with stranded circular conductors. Due to different conductor sharp or dimensions and cable constructions the minimum and maximum application range may be extendable. Please contact your local sales representative. Duyen Ha Power Equipment Co.,Ltd 21 Cold-Applied Terminations CSTI/CSTO Silicone cold-shrink termination with integrated stress control for XLPE cables up to 24 kV General Description The Raychem CSTI/CSTO family of cold shrink terminations is made from a high performance, liquid silicone material. Specially formulated for excellent track and split resistance, the terminations deliver long and trouble free service. The extra long, silicone stress cone is integrated with the termination and eliminates positioning issues common with normal cold shrink terminations. Moisture sealing at the lug is integrated into the termination body, eliminating the need for additional sealing tapes. Easy release sprial hold out ensures one-step installation Main technical parameters Cable insulation outer diameter 11.7-52 mm Cabje conductor cross-section range 25-630 mm Max system voltage 17.5 kv Impulse voltage withstand 95 kv Partial discharge @1.73UO <3 pc AC voltage withstand .5 min 39 kv DC voltage withstand .15 min 35 kv 2 MEDIUM VOLTAGE CABLE ACCESSORIES Features & Benefits 22 • • • • • • • • • One piece, pre-expanded termination on a spiral hold out for easy installation Integrated stress cone and faraday cage for excellent electrical stress control Longer stress cone eliminated installer positioning error Integrated lug seal with pre-installed sealant for a Class 1 termination Suitable for use with crimp or mechanical connectors Excellent electrical properties with superior track resistance Outstanding weathering and UV resistance for a long service life Minimum 24 months shelf life Tested to IEC 60502-4 S e le c tio n Info rm atio n: d im e nsio ns show n in m illim e te rs 12 k V 3-C o re c a ble Cross-section (mm2 ) Indoor termination Kit description Diameter over insulation(mm) Comment 25-35 50 -120 150 -18 5 24 0 -4 0 0 50 0 C S T I-12-2535-T C S T I-12-50 12-T C S T I-12-1518 -T C S T I-12-24 4 0 -T C S T I-12-50 0 -T 11.7~18 16 .5~27 16 .5~27 24 .5~34 .5 32.5~52 Tape shielded, unarm oured Tape shielded, unarm oured Tape shielded, unarm oured Tape shielded, unarm oured Tape shielded, unarm oured C S TO -12-2535-T C S TO -12-50 12-T C S TO -12-1518 -T C S TO -12-24 4 0 -T C S TO -12-50 0 -T 11.7~18 16 .5~27 16 .5~27 24 .5~34 .5 32.5~52 Tape shielded, unarm oured Tape shielded, unarm oured Tape shielded, unarm oured Tape shielded, unarm oured Tape shielded, unarm oured Outdoor termination 25-35 50 -120 150 -18 5 24 0 -4 0 0 50 0 Duyen Ha Power Equipment Co.,Ltd 12 k V 1-C o re c a ble Cross-section (mm2 ) Indoor termination Kit description Diameter over insulation(mm) Comment 50 -150 18 5-4 0 0 50 0 -6 30 C S T I-12-50 15-S C -T C S T I-12-18 4 0 -S C -T C S T I-12-50 6 3-S C -T 16 .5~27 24 .5~34 .5 32.5~52 Tape shielded, unarm oured Tape shielded, unarm oured Tape shielded, unarm oured C S TO -12-50 15-S C -T C S TO -12-18 4 0 -S C -T C S TO -12-50 6 3-S C -T 16 .5~27 24 .5~34 .5 32.5~52 Tape shielded, unarm oured Tape shielded, unarm oured Tape shielded, unarm oured Cross-section (mm2 ) Indoor termination Kit description Diameter over insulation(mm) Comment 35-9 5 120 -18 5 24 0 -30 0 C S T I-24 -359 5-T C S T I-24 -1218 -T C S T I-24 -24 30 -T 16 .5~27 24 .5~34 .5 24 .5~34 .5 Tape shielded, unarm oured Tape shielded, unarm oured Tape shielded, unarm oured C S TO -24 -359 5-T C S TO -24 -1218 -T C S TO -24 -24 30 -T 16 .5~27 24 .5~34 .5 24 .5~34 .5 Tape shielded, unarm oured Tape shielded, unarm oured Tape shielded, unarm oured Cross-section (mm2 ) Indoor termination Kit description Diameter over insulation(mm) Comment 35-9 5 120 -30 0 4 0 0 -50 0 C S T I-24 -359 5-S C -T C S T I-24 -1230 -S C -T C S T I-24 -4 0 50 -S C -T 16 .5~27 24 .5~34 .5 32.5~52 Tape shielded, unarm oured Tape shielded, unarm oured Tape shielded, unarm oured C S TO -24 -359 5-S C -T C S TO -24 -1230 -S C -T C S TO -24 -4 0 50 -S C -T 16 .5~27 24 .5~34 .5 32.5~52 Tape shielded, unarm oured Tape shielded, unarm oured Tape shielded, unarm oured Outdoor termination 50 -150 18 5-4 0 0 50 0 -6 30 24 k V 3 -C o re c a ble Outdoor termination 24 k V 1-C o re c a ble Outdoor termination 35-9 5 120 -30 0 4 0 0 -50 0 The application range given in the table is based on polymeric insulated cable according to IEC 60502 standard with stranded circular conductors. Due to different conductor sharp or dimensions and cable constructions the minimum and maximum application range may be extendable. Please contact your local sales representative. Duyen Ha Power Equipment Co.,Ltd MEDIUM VOLTAGE CABLE ACCESSORIES 35-9 5 120 -18 5 24 0 -30 0 23 Elbows & Accessories ELBC 810 screened separable connector up to 17.5 kV 800 A General Description Raychem ELBC-810 screened separable connectors are used to connect XLPE cables to electrical equipment (e.g. RMU, switchgear, transformer, etc.) using CENELEC bushings type “C” specified for 630/1250 A up to 17.5 kV. Made of a highly modified EPDM rubber, ELBC is fully screened and fully submersible, suitable for indoor and outdoor installations. For a wide application range, the design incorporates one body and five stress cones to cover all cross-sections, from 25 sq. mm to 500 sq. mm. The overall and cut-back dimensions are designed to take up minimum space in the terminal box. ELBC 810 elbow connectors are equipped with a capacitive test point for determining whether the circuit is energised. This test point is protected by a conductive cap. ELBC is compatible for use with both mechanical and compression lugs which can be ordered separately. Pre-engineered design of the mechanical lug optimizes the contact resistance between the connector and conductor. Installation is very easy, requiring only a standard socket spanner and no additional space. The separable connector is easily connected with the bushing and junction that comply to EN50180/50181 DIN47636. Accessories such as test rods, earth plugs and front terminals are compatible for use with the TE range of RSTI and ELBC separable connectors. MEDIUM VOLTAGE CABLE ACCESSORIES Features & Benefits 24 • ELBC screened separable connectors are made of high modified EPDM rubber which ensures the high dielectric strength and elongation at break. • A thick conductive EPDM jacket protects the connection system against unintentional contact. • Unique design makes it fully shielded and submersible when matched with the right bushing or plug. • Unique design ensures the ELBC has a current rating up to 800A. ELBC is designed to fit 630/1250 A type “C” bushings, as specified by EN50180 and EN50181. • The screened separable connector exceeds CENELEC HD 629.1 S2 requirements, which includes BS, VDE and other international specifications. • The compact design supports the use of double "T" connections inside cable cabinets. • A wide application range covers cable cross-sections from 25 sq. mm to 500 sq. mm. • Compatible for use with mechanical or compression type lugs. • Easily accessible back plug with capacitive test point. • Few accessories required for system test, double “T” and earth connection. • Complete kit including lugs facilitates easy installation and storage. • 100% routine test for PD & AC. D e sig n & C o nstruc tio n Te c hnic a l D ata 1. Outer conductive layer 2. Insulated layer 3. Farady cage 4. Earthing eye and grounding kit 5. Stress cone 6. Compression / mechanical lug 7. Back plug 8. Stud-bolt set 9. End cap 10. Threaded bolt Cable insulation range 15.5 ~ 37 mm Cable cross-section range 25 ~ 500 mm2 Max.Rated voltage 17.5 kV Rated current 800 A 2Uo PD < 2 pC AC withstand, 5min 54 kV Thermal short, 1s 54 kA Dynamic short, 1s 85 kA Meet the international CENELEC HD 629.1 S2 specification and GB 12706.4:2008 Duyen Ha Power Equipment Co.,Ltd S e le c tio n Info rm atio n: d im e nsio ns show n in m illim e te rs 6 / 10 ( 12 ) k V a nd 8 .7/ 15 ( 17.5 ) k V sing le -c o re, w ith c o m pre ssio n lug Front Connector Rear Connector Insulation E L B C -8 10 -25C -S C E L B C -8 10 -35C -S C E L B C -8 10 -50 C -S C E L B C -8 10 -70 C -S C E L B C -8 10 -9 5C -S C E L B C -8 10 -120 C -S C E L B C -8 10 -150 C -S C E L B C -8 10 -18 5C -S C E L B C -8 10 -24 0 C -S C E L B C -8 10 -30 0 C -S C E L B C -8 10 -4 0 0 C -S C E L B C -8 10 -50 0 C -S C E L B C -C C -8 10 -25C -S C E L B C -C C -8 10 -35C -S C E L B C -C C -8 10 -50 C -S C E L B C -C C -8 10 -70 C -S C E L B C -C C -8 10 -9 5C -S C E L B C -C C -8 10 -120 C -S C E L B C -C C -8 10 -150 C -S C E L B C -C C -8 10 -18 5C -S C E L B C -C C -8 10 -24 0 C -S C E L B C -C C -8 10 -30 0 C -S C E L B C -C C -8 10 -4 0 0 C -S C E L B C -C C -8 10 -50 0 C -S C 15.5~19 15.5~19 15.5~19 18 .0 ~23 18 .0 ~23 22.0 ~27 22.0 ~27 22.0 ~27 26 .0 ~32 26 .0 ~32 31.0 ~37 31.0 ~37 Cross Section (mm2 ) Ф (mm) 25 35 50 70 95 120 150 18 5 24 0 30 0 400 50 0 6 / 10 ( 12 ) k V a nd 8 .7/ 15 ( 17.5 ) k V sing le -c o re w ith m e c ha nic a l lug Rear Connector Insulation E L B C -8 10 -2550 -S C E L B C -8 10 -70 9 5-S C E L B C -8 10 -1218 -S C E L B C -8 10 -24 30 -S C E L B C -8 10 -4 0 0 -S C E L B C -C C -8 10 -2550 -S C E L B C -C C -8 10 -70 9 5-S C E L B C -C C -8 10 -1218 -S C E L B C -C C -8 10 -24 30 -S C E L B C -C C -8 10 -4 0 0 -S C 15.5~19 18 .0 ~23 22.0 ~27 26 .0 ~32 31.0 ~37 Cross Section (mm2 ) Ф (mm) 25~50 70 ~9 5 120 ~18 5 24 0 ~30 0 400 6 / 10 ( 12 ) k V a nd 8 .7/ 15 ( 17.5 ) k V, 3 -c o re c a ble se ts, w ith he at shrink a ble trifurc atio n k its Front Connector Rear Connector Insulation E L B C -8 10 -2550 E L B C -8 10 -70 9 5 E L B C -8 10 -1218 E L B C -8 10 -24 30 E L B C -C C -8 10 -2550 E L B C -C C -8 10 -70 9 5 E L B C -C C -8 10 -1218 E L B C -C C -8 10 -24 30 15.5~19 18 .0 ~23 22.0 ~27 26 .0 ~32 Cross Section (mm2 ) Ф (mm) 25~50 70 ~9 5 120 ~18 5 24 0 ~30 0 6 / 10 ( 12 ) k V a nd 8 .7/ 15 ( 17.5 ) k V, 3 -c o re c a ble se ts, w ith c o ld shrink a ble trifurc atio n k its Front Connector Rear Connector Insulation E L B C -8 10 -2550 -C T R E L B C -8 10 -70 9 5-C T R E L B C -8 10 -1218 -C T R E L B C -8 10 -24 30 -C T R E L B C -8 10 -4 0 0 -C T R E L B C -C C -8 10 -2550 -C T R E L B C -C C -8 10 -70 9 5-C T R E L B C -C C -8 10 -1218 -C T R E L B C -C C -8 10 -24 30 -C T R E L B C -C C -8 10 -4 0 0 -C T R 15.5~19 18 .0 ~23 22.0 ~27 26 .0 ~32 31.0 ~37 Cross Section (mm2 ) Ф (mm) 25~50 70 ~9 5 120 ~18 5 24 0 ~30 0 400 R e late d te st re po rt Reference No. Voltage (kV) Specification 20 10 J D L 4 4 1 17.5 G B / T 1270 6 .4 -20 0 8 IE C 6 0 50 2.4 -20 0 5" Duyen Ha Power Equipment Co.,Ltd MEDIUM VOLTAGE CABLE ACCESSORIES Front Connector 25 Elbows & Accessories ELBC 824 screened separable connector up to 24 kV, 800 A General Description Raychem ELBC-824 screened separable connectors are used to connect XLPE cables to electrical equipment ( e.g. RMU, switchgear, transformer, etc.) using CENELEC bushings type “C” specified for 630/1250 A up to 24 kV. Made of a highly modified EPDM rubber, ELBC is fully screened and fully submersible, suitable for indoor and outdoor installations. For a wide application range, the design incorporates one body and five stress cones to cover all cross-sections, from 35sq.mm to 400sq. mm. The overall and cut-back dimensions are designed to take up minimun space in the terminal box. ELBC 810 elbow connectors are equipped with a capacitive test point for determining whether the circuit is energised. This test point is protected by a conductive cap. Mechanical lug and compression lug is ready for customer ordering. Both of them could cover the cable cross-section from 35sqmm to 400sqmm. Pre-engineered design of the mechanical lug optimizes the contact resistance between the connector and conductor. Installation is very easy, requiring only a standard socket spanner and no additional space. The separable connector is easily connected with the bushing and junction that comply to EN50180/50181 DIN47636. Accessories such as test rods, earth plugs and front terminals are compatible of use with the TE range of RSTI and ELBC separable connectors. MEDIUM VOLTAGE CABLE ACCESSORIES Features & Benefits 26 • ELBC screened separable connector is made of high modified EPDM rubber which ensures the high dielectric strength and elongation at break. • A thick conductive EPDM jacket protects the connection system against unintentional contact. • Unique design makes it fully shielded and submersible when matched with the right bushing or plug. • Unique design ensures the ELBC has a current rating up to 800 A. ELBC is designed to fit 630/1250 A type “C” bushings, as specified by EN50180 and EN50181. • The screened separable connector exceeds CENELEC HD 629.1 S2 requirements, which includes BS, VDE and other international specifications. • The compact design supports the use of double "T" connections inside cable cabinets. • A wide application range covers cable cross-section from 35sq. mm to 400sq. mm. • Compatible for use with mechanical or compression type lugs. • Easily accessible back plug with capacitive test point. • Few accessories required for system test, double “T” and earth connection. • Complete kit including lugs facilitates easy installation and storage. • 100% routine test for PD & AC. D e sig n & C o nstruc tio n 1. Outer conductive layer 2. Insulated layer 3. Farady cage 4. Earthing eye and grounding kit 5. Stress cone 6. Compression and mechanical lug 7. Back plug 8. Threaded pin kit 9. End cap 10. Threaded bolt 9 8 7 1 6 2 Te c hnic a l D ata C able insulation range C able c ross-sec tion range Max .R ated voltage R ated c urrent B asic im pulse level 2U o P D A C w ithstand, 5 m in T herm al short, 1 s D y nam ic short, 1 s 15.5 ~ 37 m m 35 ~ 4 0 0 m m 2 24 kV 80 0 A 125 kV < 5 pC 54 kV 54 kA 8 5 kA Meet the international CENELEC HD 629.1 S2 specification and GB 12706.4:2008 3 5 4 Duyen Ha Power Equipment Co.,Ltd S e le c tio n Info rm atio n: d im e nsio ns show n in m illim e te rs 12 / 2 0 ( 24 ) k V S ing le -c o re, c o ppe r c o nd uc to r w ith c o m pre ssio n c o ppe r lug Front Connector Rear Connector Insulation E L B C -8 24 -35C -S C E L B C -8 24 -50 C -S C E L B C -8 24 -70 C -S C E L B C -8 24 -9 5C -S C E L B C -8 24 -120 C -S C E L B C -8 24 -150 C -S C E L B C -8 24 -18 5C -S C E L B C -8 24 -24 0 C -S C E L B C -8 24 -30 0 C -S C E L B C -8 24 -4 0 0 C -S C E L B C -C C -8 24 -35C -S C E L B C -C C -8 24 -50 C -S C E L B C -C C -8 24 -70 C -S C E L B C -C C -8 24 -9 5C -S C E L B C -C C -8 24 -120 C -S C E L B C -C C -8 24 -150 C -S C E L B C -C C -8 24 -18 5C -S C E L B C -C C -8 24 -24 0 C -S C E L B C -C C -8 24 -30 0 C -S C E L B C -C C -8 24 -4 0 0 C -S C 18 ~23 18 ~23 18 ~23 22~27 22~27 26 ~32 26 ~32 26 ~32 31~37 31~37 Cross Section (mm2 ) Φ (mm) 35 50 70 95 120 150 18 5 24 0 30 0 400 12 / 2 0 ( 24 ) k V S ing le -c o re w ith m e c ha nic a l lug Rear Connector Insulation E L B C -8 24 -3570 -S C E L B C -8 24 -9 512-S C E L B C -8 24 -1524 -S C E L B C -8 24 -30 4 0 -S C E L B C -C C -8 24 -3570 -S C E L B C -C C -8 24 -9 512-S C E L B C -C C -8 24 -1524 -S C E L B C -C C -8 24 -30 4 0 -S C 18 ~23 22~27 26 ~32 31~37 Cross Section (mm2 ) Φ (mm) 35~70 9 5~120 150 ~24 0 30 0 ~4 0 0 Trifurc atio n k its fo r 3 -c o re c a ble s T R F C -H 1 T R F C -C 1 T R F C -C 2 H eat S hrinkable trifurc ation kits C old S hrinkable trifurc ation kits C old S hrinkable trifurc ation kits 3*1 M tubing and 1 pc breakout and 1 m earth braid 3*50 0 m m tube and 1 pc breakout and 1.4 m earth braid 6 *50 0 m m tube and 1 pc breakout and 1.4 m earth braid A c c e sso rie s Test Rod R S T I-6 8 T R R S T I-6 8 T R L R S T I-6 8 T R A 310 m m 4 60 mm K it inc luding 2 short and 1 long rods Terminal Plug R S T I-6 8 T P Earthing Adapter R S T I-6 8 E A 20 R S T I-6 8 E A 25 B all Φ 20 m m B all Φ 25 m m Single Connection Material for three phases 1* E L B C -8 24 -x x x x ( kit) Live end Seal Material for three phases 1* E L B C -8 24 -x x x x ( kit) 1* R S T I 6 8 T P MEDIUM VOLTAGE CABLE ACCESSORIES Front Connector R e late d te st re po rt Reference No. 20 11J D L 56 9 Duyen Ha Power Equipment Co.,Ltd Voltage (kV) Specification 24 G B / T 1270 6 .4 -20 0 8 IE C 6 0 50 2.4 -20 0 5 27 Elbows & Accessories RSTI-58 Screened separable connection system 800 A up to 24 kV General Description RSTI: Raychem RSTI-58 screened separable connectors are designed to connect singleand three-core polymeric cables to medium-voltage gas insulated switchgear and other equipment using CENELEC bushings type “C” specified for 630/1250 A up to 24 kV. Made of a highly modified silicone rubber and protected by a thin-walled outer conductive screen connected to earth, RSTI-58 connectors are equally suited for indoor and outdoor installation. Supporting a wide application range, the design incorporates one body and two stress cone adapters to cover all cross-sections from 25 to 300 mm 2 . The overall and cut-back dimensions are designed to take up minimum space in the terminal box. RSTI-58 connectors are equipped with a capacitive test point for determining whether the circuit is energized. This test point is protected by a conductive cap. After cable preparation and lubrication, the stress control adapter is simply slid into place, followed by the screened connector body. These two components can be installed under virtually any conditions. A separable mounting system ensures easy installation of the connector onto the bushing. All kits include highperformance multi-range mechanical or DIN compression lugs matching the design of the RSTI-58 connector. The RSTI-CC screened coupling connector is designed to mate with the rear end of the base screened connector system connector system is designed designed for 24 kV. MEDIUM VOLTAGE CABLE ACCESSORIES Features & Benefits 28 RSTI: • The insulation of the connector is made of a highly modified silicone rubber characterised by high tracking resistance, elongation at break and non-flammability. • A thin-walled screen is permanently bonded onto the insulation and protects the connection system against unintentional contact. • The screened connector need not be removed for oversheath testing. • The screened cable connector exceeds CENELEC HD 629.1 S2 requirements, which includes BS, VDE and other international specifications. • Design fits 630/1250 A bushings type “C” as specified by EN50180 and EN50181. • The compact design supports the use of double “T” connections inside standard terminal boxes. • The wide application range covers cable cross-sections from 25 to 300 mm2 . • Conductor connection with mechanical or DIN lugs. • Easily accessible rear plug with capacitive test point. • Few accessories required for system test, double “T” and earth connection. • Complete kit including lugs facilitates installation and storage. RSTI-CC: • The insulation of the coupling connector is made of a highly modified silicone rubber characterised by high tracking resistance, elongation at break and nonflammability. • A thin-walled screen is permanently bonded onto the insulation and protects the connection system against accidental contact. • The screened coupling connector need not be removed for oversheath testing. • The combination of screened connector and coupling connector exceeds CENELEC HD 629.1 S2 requirements, which include BS, VDE and other international specifications. • The combination of screened connector and coupling connector fits 630/1250 A bushings type “C” as specified by EN50180 and EN50181. • The compact design supports the use of double “T” connections inside standard terminal boxes. • The wide application range covers cable cross-sections from 25 to 300 mm2 . • Conductor connection with mechanical or DIN lugs. • Easily accessible rear plug with capacitive test point. • Few accessories required for system test and earth connection. • Complete kit including lugs for easier installation and storage. Duyen Ha Power Equipment Co.,Ltd S e le c tio n Info rm atio n: d im e nsio ns show n in m illim e te rs Cross Section (mm2 ) Diameter Reference number Core insulation (mm) R S T I-58 10 R S T I-58 11 R S T I-58 12 R S T I-58 13 R S T I-58 14 R S T I-58 15 R S T I-58 26 R S T I-58 27 R S T I-58 28 R S T I-58 29 25 35 50 70 95 120 150 18 5 24 0 30 0 12.7- 23.4 12.7- 23.4 12.7- 23.4 12.7- 23.4 12.7- 23.4 12.7- 23.4 21.2- 34 .6 21.2- 34 .6 21.2- 34 .6 21.2- 34 .6 R S T I-58 51 35-9 5 12.7- 23.4 R S T I-58 52 9 5-120 12.7- 23.4 R S T I-58 53 9 5-24 0 17.0 - 30 .1 R S T I-58 54 150 -24 0 21.2- 34 .6 R S T I-58 55 18 5-30 0 21.2- 34 .6 R S T I-C C -58 10 R S T I-C C -58 11 R S T I-C C -58 12 R S T I-C C -58 13 R S T I-C C -58 14 R S T I-C C -58 15 R S T I-C C -58 26 R S T I-C C -58 27 R S T I-C C -58 28 R S T I-C C -58 29 25 35 50 70 95 120 150 18 5 24 0 30 0 12.7- 23.4 12.7- 23.4 12.7- 23.4 12.7- 23.4 12.7- 23.4 12.7- 23.4 21.2- 34 .6 21.2- 34 .6 21.2- 34 .6 21.2- 34 .6 R S T I-C C -58 51 35-9 5 12.7- 23.4 R S T I-C C -58 52 9 5-120 12.7- 23.4 R S T I-C C -58 53 9 5-24 0 17.0 - 30 .1 R S T I-C C -58 54 150 -24 0 21.2- 34 .6 R S T I-C C -58 55 18 5-30 0 21.2- 34 .6 Duyen Ha Power Equipment Co.,Ltd Lugs type Voltage Level Type C om pression lugs C om pression lugs C om pression lugs C om pression lugs C om pression lugs C om pression lugs C om pression lugs C om pression lugs C om pression lugs C om pression lugs Mec hanic al lugs and shear bolts Mec hanic al lugs and shear bolts Mec hanic al lugs and shear bolts Mec hanic al lugs and shear bolts Mec hanic al lugs and shear bolts C om pression lugs C om pression lugs C om pression lugs C om pression lugs C om pression lugs C om pression lugs C om pression lugs C om pression lugs C om pression lugs C om pression lugs Mec hanic al lugs and shear bolts Mec hanic al lugs and shear bolts Mec hanic al lugs and shear bolts Mec hanic al lugs and shear bolts Mec hanic al lugs and shear bolts 12/ 24 12/ 24 12/ 24 12/ 24 12/ 24 12/ 24 12/ 24 12/ 24 12/ 24 12/ 24 F ront F ront F ront F ront F ront F ront F ront F ront F ront F ront 12/ 24 F ront 12 F ront 12/ 24 F ront 12/ 24 F ront 12/ 24 F ront 12/ 24 12/ 24 12/ 24 12/ 24 12/ 24 12/ 24 12/ 24 12/ 24 12/ 24 12/ 24 R ear R ear R ear R ear R ear R ear R ear R ear R ear R ear 12/ 24 R ear 12 R ear 12/ 24 R ear 12/ 24 R ear 12/ 24 R ear MEDIUM VOLTAGE CABLE ACCESSORIES Catalog Number 29 Elbows & Accessories RSTI-68 Screened separable connection system 1250 A up to 42 kV General Description Raychem RSTI screened separable connectors are designed to connect single- and three-core polymeric cables to medium-voltage gas insulated switchgear and other equipment using CENELEC bushings Type C1=630 A and C2=1250 A, specified up to 42 kV. Made of a highly modified silicone rubber and protected by a thin walled outer conductive screen connected to earth, RSTI connectors are equally suited for indoor and outdoor installation. Supporting a wide application range, the design incorporates one body and two stress cone adapters to cover all cross-sections from 35 to 300 mm2 . The overall and cut back dimensions are designed to take up minimum space in the terminal box. RSTI connectors are equipped with a capacitive test point for determining whether the circuit is energised. A conductive cap protects this test point. MEDIUM VOLTAGE CABLE ACCESSORIES Features & Benefits 30 • The insulation of the connector is made of a highly modified silicone rubber characterised by high tracking resistance, elongation at break and non-flammability. • A thin walled screen is permanently bonded onto the insulation and protects the connection system against accidental contact. • The screened connector need not be removed for over sheath testing. • The screened cable connector exceeds CENELEC HD 629.1 S2 requirements, which includes BS; VDE and other international specifications. • Design fits 630 A and 1250 A bushings (Interface “C1” and “C2”) as specified by EN 50180 and EN 50181. • The compact design supports the use of double “T” connections inside standard terminal boxes. • The wide application range covers cable cross sections from 35 to 300 mm2 . • Conductor connection with mechanical, DIN or deep indent lugs. • Easily accessible rear plug with capacitive test point. • Few accessories required for system test, double “T” and earth connection. • Complete kit including lugs facilitates installation and storage. Duyen Ha Power Equipment Co.,Ltd S e le c tio n Info rm atio n: d im e nsio ns show n in m illim e te rs Cross Section (mm2 ) Diameter Reference number Core insulation (mm) Lugs type Voltage Level Type R S T I-6 8 11 R S T I-6 8 12 R S T I-6 8 13 R S T I-6 8 14 R S T I-6 8 15 R S T I-6 8 16 R S T I-6 8 17 R S T I-6 8 18 R S T I-6 8 21 R S T I-6 8 22 R S T I-6 8 23 R S T I-6 8 24 R S T I-6 8 25 R S T I-6 8 26 R S T I-6 8 27 R S T I-6 8 28 R S T I-6 8 51 R S T I-6 8 52 R S T I-6 8 53 R S T I-6 8 55 R S T I-C C -6 8 11 R S T I-C C -6 8 12 R S T I-C C -6 8 13 R S T I-C C -6 8 14 R S T I-C C -6 8 15 R S T I-C C -6 8 16 R S T I-C C -6 8 17 R S T I-C C -6 8 18 R S T I-C C -6 8 21 R S T I-C C -6 8 22 R S T I-C C -6 8 23 R S T I-C C -6 8 24 R S T I-C C -6 8 25 R S T I-C C -6 8 26 R S T I-C C -6 8 27 R S T I-C C -6 8 28 R S T I-C C -6 8 51 R S T I-C C -6 8 52 R S T I-C C -6 8 53 R S T I-C C -6 8 55 50 70 95 120 150 18 5 24 0 30 0 50 70 95 120 150 18 5 24 0 30 0 35-9 5 9 5-150 120 -24 0 18 5-30 0 50 70 95 120 150 18 5 24 0 30 0 50 70 95 120 150 18 5 24 0 30 0 35-9 5 9 5-150 120 -24 0 18 5-30 0 22.4 - 35.5 22.4 - 35.5 22.4 - 35.5 22.4 - 35.5 28 .9 - 4 2.0 28 .9 - 4 2.0 28 .9 - 4 2.0 28 .9 - 4 2.0 22.4 - 35.5 22.4 - 35.5 22.4 - 35.5 22.4 - 35.5 28 .9 - 4 2.0 28 .9 - 4 2.0 28 .9 - 4 2.0 28 .9 - 4 2.0 22.4 - 35.5 22.4 - 35.5 28 .9 - 4 2.0 28 .9 - 4 2.0 22.4 - 35.5 22.4 - 35.5 22.4 - 35.5 22.4 - 35.5 28 .9 - 4 2.0 28 .9 - 4 2.0 28 .9 - 4 2.0 28 .9 - 4 2.0 22.4 - 35.5 22.4 - 35.5 22.4 - 35.5 22.4 - 35.5 28 .9 - 4 2.0 28 .9 - 4 2.0 28 .9 - 4 2.0 28 .9 - 4 2.0 22.4 - 35.5 22.4 - 35.5 28 .9 - 4 2.0 28 .9 - 4 2.0 A l C om pression lugs A l C om pression lugs A l C om pression lugs A l C om pression lugs A l C om pression lugs A l C om pression lugs A l C om pression lugs A l C om pression lugs C u C om pression lugs C u C om pression lugs C u C om pression lugs C u C om pression lugs C u C om pression lugs C u C om pression lugs C u C om pression lugs C u C om pression lugs Mec hanic al lugs and shear bolts Mec hanic al lugs and shear bolts Mec hanic al lugs and shear bolts Mec hanic al lugs and shear bolts A l C om pression lugs A l C om pression lugs A l C om pression lugs A l C om pression lugs A l C om pression lugs A l C om pression lugs A l C om pression lugs A l C om pression lugs C u C om pression lugs C u C om pression lugs C u C om pression lugs C u C om pression lugs C u C om pression lugs C u C om pression lugs C u C om pression lugs C u C om pression lugs Mec hanic al lugs and shear bolts Mec hanic al lugs and shear bolts Mec hanic al lugs and shear bolts Mec hanic al lugs and shear bolts 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 F ront F ront F ront F ront F ront F ront F ront F ront F ront F ront F ront F ront F ront F ront F ront F ront F ront F ront F ront F ront R ear R ear R ear R ear R ear R ear R ear R ear R ear R ear R ear R ear R ear R ear R ear R ear R ear R ear R ear R ear Duyen Ha Power Equipment Co.,Ltd MEDIUM VOLTAGE CABLE ACCESSORIES Catalog Number 31 Elbows & Accessories RSES 400 A screened, separable elbow connection system 400 A for 24 kV and 36 kV General Description Raychem RSES screened, separable elbow connectors are designed to connect single and three-core polymeric cables to medium-voltage gas-insulated switchgear and other equipment using CENELEC bushing Type "B" specified for 400 A up to 36 kV. Made of a highly modified silicone rubber and protected by a thin-walled outer conductive screen connected to earth, RSES elbow connectors are equally suited for indoor and outdoor installation. Supporting a wide application range, the design incorporates one body and two stress cone adapters to cover all cross-sections from 50 to 300 mm 2 . The overall and cut-back dimensions are designed to take up minimum space in the terminal box. RSES elbow connectors are equipped with a capacitive test point for determining whether the circuit is energised. This test point is protected by a conductive cap. After cable preparation and lubrication, the stress control adapter is simply slid into place, followed by the screened connector body. These two components can be installed under virtually any conditions. A separable mounting system ensures easy installation of the connector onto the bushing. All kits include high-performance multi-range mechanical lugs matching the design of the RSES elbow connector. MEDIUM VOLTAGE CABLE ACCESSORIES Features & Benefits 32 • The insulation of the connector is made of a highly modified silicone rubber characterised by high tracking resistance, elongation at break and non-flammability. • A thin-walled screen is permanently bonded onto the insulation and protects the connection system against accidental contact. • The screened connector doesn't need to be removed for oversheath testing. • The screened cable connector exceeds CENELEC HD 629.1 S2 requirements, which includes BS, VDE and other international specifications. • Design fits 400 A bushings (interface "B") as specified by EN 50180 and EN 50181. • The wide application range covers cable cross-sections from 50 to 300 mm 2 . • Conductor connection with mechanical lugs, designed to accept aluminium and copper conductors. • Easily accessible capacitive test point. • Few accessories required for system test. • Complete kit including lugs facilitates easy installation and storage. D e sig n & C o nstruc tio n A pplic atio ns 6 9 5 3 8 1 2 4 7 1. Screened body 2. Inner screen 3. Mechanical lug 4. Stress cone adapter 5. Earthing eye and ground lead 6. Pin 7. Test point 8. Conductive covering cap 9. Stainless steel bail Duyen Ha Power Equipment Co.,Ltd Te c hnic a l D ata C able insulation diam eter range C onnec tor c ross-sec tion range Max im um system voltage C ontinuous c urrent rating B asic im pulse level P artial disc harge at 2 U 0 A C voltage w ithstand, 5 m in D C voltage w ithstand, 15 m in T herm al short c irc uit, 1 s D y nam ic short c irc uit T he adapters m eet the international C E N E L E C H D 6 29 .1 S 2 spec ific ation. 22.4 - 4 2.0 m m 50 - 30 0 m m 2 36 kV 400 A 19 4 kV < 2 pC 8 5.5 kV 114 kV 18 .1 kA 4 8 .5 kA S e le c tio n Info rm atio n: d im e nsio ns show n in m illim e te rs S c re e ne d se pa ra ble e lbow c o nne c tio n sy ste m w ith m e c ha nic a l lug s a nd she a r bo lts Cross section (mm2 ) Insulation Diameter (mm) Reference Number 70 ~9 5 9 5~24 0 18 5~30 0 22.4 ~35.5 22.4 ~35.5 22.4 ~35.5 R S E S -6 4 51 R S E S -6 4 52 R S E S -6 4 54 3 6 k V, C o nd uc to r m ate ria l: A l o r C u Cross section (mm2 ) Insulation Diameter (mm) Reference Number 50 ~9 5 9 5~150 120 ~24 0 18 5~30 0 22.4 ~35.5 22.4 ~35.5 28 .9 ~4 2.0 28 .9 ~4 2.0 R S E S -6 4 51 R S E S -6 4 52 R S E S -6 4 53 R S E S -6 4 55 R e late d te st re po rts Reference No. Voltage (kV) Specification P P R -210 2 24 C E L E N E C H D 6 29 .1 S 2 20 0 6 Duyen Ha Power Equipment Co.,Ltd MEDIUM VOLTAGE CABLE ACCESSORIES 24 k V, C o nd uc to r m ate ria l: A l o r C u 33 Elbows & Accessories RSES / RSSS 250 A Screened adaptor system 250 A, up to 24 kV General Description Raychem RSES/RSSS screened, separable adaptors are designed to connect single-core polymeric cables to medium voltage equipment (transformers, switchgears, motors etc.) using CENELEC bushings Type "A" specified for 250 A up to 24 kV. Made of crosslinked EPDM and protected with a minimum 3 mm moulded conductive shield connected to earth, Raychem deadbreak adaptors are suitable for both indoor and outdoor installations. Their wide application range allows a minimum number of bodies to cover several different cable cross-sections without the need for additional cable adaptors. The cut-back dimensions for all cable sizes are the same for RSSS and RSES systems. Screened adaptors are equipped with a capacitive test point to ensure that the circuit is not energized before disconnection. The capacitive test point is protected by a conductive cap. A range of high strength bimetallic compression connectors tested according to IEC 61238-1:2003 are offered to connect both aluminium and copper conductors. After cable preparation and lubrication, the adaptors can simply be slid into place under virtually all conditions. A separable mounting system provides for an easy installation of the adaptor onto the bushing. Features & Benefits MEDIUM VOLTAGE CABLE ACCESSORIES • • • • • • 34 Premolded deadbreak elbow/straight connection. Thick walled screen protects against unintentional contact. Design fits bushing profile “A” in accordance with EN50181. Built in capacitive test point to determine the circuit status. Cold applied range taking product. Conductor connection with bimetallic compression lugs. D e sig n & C o nstruc tio n 1. Screened body 2. Capacitive test point 3. Stress cone 4. Conductive cable entrance 5. Earthing eye 6. Inner screen 7. Retaining shoulder 8. Compression pin-connector 9. Lifting eye 10. Pin 11. Compression connector Duyen Ha Power Equipment Co.,Ltd Te c hnic a l D ata C able insulation diam eter range C onnec tor c ross sec tion range Max im um system voltage C ontinuous c urrent rating B asic im pulse level P artial disc harge at 2 U o A C voltage w ithstand D C voltage w ithstand RSES 250A 17.5 kV RSSS 250A 17.5 kV RSES 250A 24 kV RSSS 250A 24 kV 13.5 ~ 33.5 m m 35 ~ 120 m m 2 17.5 kV 250 A 9 5 kV < 5 pC 4 0 kV, 5 m in 35 kV, 15 m in 13.5 ~ 24 .1 m m 16 ~ 9 5 m m 2 17.5 kV 250 A 9 5 kV < 5 pC 4 0 kV, 5 m in 35 kV, 15 m in 13.5 ~ 33.5 m m 16 ~ 120 m m 2 24 kV 250 A 125 kV < 5 pC 50 kV, 1 m in 9 6 kV, 30 m in 13.5 ~ 26 .5 m m 16 ~ 9 5 m m 2 24 kV 250 A 125 kV < 5 pC 50 kV, 1 m in 9 6 kV, 30 m in The adaptors have been tested in accordance with the international specifications (e.g. ANSI/IEEE 386, IEC 540, VDE 0278 and GB 12706-2002). The bimetallic connectors have been tested in accordance with VDE 0220 on aluminium and copper conductors. S e le c tio n Info rm atio n: d im e nsio ns show n in m illim e te rs Cross section (mm2 ) Insulation Diameter (mm) Reference Ordering # Bushing Type 35 C u 50 C u 70 C u 95 Cu 120 C u 17.0 ~20 .0 17.0 ~20 .0 20 .0 ~23.0 20 .0 ~23.0 23.0 ~24 .6 R S E S -10 35-S C R S E S -10 50 -S C R S E S -10 70 -S C R S E S -10 9 5-S C R S E S -10 12-S C Ty pe A ( 250 A ) Ty pe A ( 250 A ) Ty pe A ( 250 A ) Ty pe A ( 250 A ) Ty pe A ( 250 A ) Insulation Diameter (mm) Reference Ordering # Bushing Type 17.0 ~20 .0 17.0 ~20 .0 20 .0 ~23.0 20 .0 ~23.0 23.0 ~24 .6 R S S S -10 35-S C R S S S -10 50 -S C R S S S -10 70 -S C R S S S -10 9 5-S C R S S S -10 12-S C Ty pe A ( 250 A ) Ty pe A ( 250 A ) Ty pe A ( 250 A ) Ty pe A ( 250 A ) Ty pe A ( 250 A ) S c re e ne d S tra ig ht A d a pte rs 2 5 0 A 17.5 k V Cross section (mm 2 ) 35 C u 50 C u 70 C u 95 Cu 120 C u S c re e ne d E lbow A d a pte rs 2 5 0 A 24 k V Diameter over insulation Cross section 16 mm 2 25 mm 2 35 mm 2 50 mm 2 70 mm 2 95 mm 2 120 mm 2 13.5~17.4 m m 16 .3~20 .8 m m 19 .6 ~24 .1 m m 23.1~27.7 m m 27.9 ~33.5 m m R S E S 520 1 R S E S 5211 − − − R S E S 520 2 R S E S 5212 − − − R S E S 520 3 R S E S 5213 R S E S 5223 − − R S E S 520 5 R S E S 5215 R S E S 5225 R S E S 5235 − − R S E S 5217 R S E S 5227 R S E S 5237 − − R S E S 5219 R S E S 5229 R S E S 5239 R S E S 524 9 − − R S E S 5224 R S E S 5234 R S E S 524 4 S c re e ne d S tra ig ht A d a pte rs 2 5 0 A 24 k V Diameter over insulation Cross section 16 mm 2 25 mm 2 35 mm 2 50 mm 2 70 mm 2 95 mm 2 13.5~17.4 m m 16 .3~20 .8 m m 19 .6 ~24 .1 m m 21.0 ~26 .5 m m R S S S 520 1 R S S S 5211 − − R S S S 520 2 R S S S 5212 − − R S S S 520 3 R S S S 5213 R S S S 5223 − R S S S 520 5 R S S S 5215 R S S S 5225 R S S S 5255 − R S S S 5217 R S S S 5227 R S S S 5257 − R S S S 5219 R S S S 5229 R S S S 5259 R e late d te st re po rts Reference No. Voltage (kV) Specification 20 0 5L Z 24 9 P P R -10 6 5 P P R -1116 P P R -1150 P P R -1117 P P R -1151 P P R -2527 P P R -2528 P P R -26 9 7 17.5 24 24 24 24 24 24 24 24 G B / T 1270 6 .4 -20 0 2 Duyen Ha Power Equipment Co.,Ltd MEDIUM VOLTAGE CABLE ACCESSORIES S c re e ne d E lbow A d a pte rs 2 5 0 A 17.5 k V V D E 0 278 V D E 0 220 C E N E L E C H D 6 29 .1 S 2:20 0 6 -0 2 LC in water 35 Elbows & Accessories RCAB Elastomeric insulating bushing boot for bushings up to 630 A, 24 kV General Description Raychem RCAB elastomeric insulating boots are moulded parts which fit over the connection between the cable lug and the inline or right-angled equipment bushing to improve phase-to-phase and phase-to-ground insulation. They are used in switchgear and transformer cable boxes where the air clearances are insufficient for normal operation, or to protect against flashover due to rodents or high humidity. The non-tracking elastomeric housing has excellent erosion resistance, dielectric properties and environmental resistance, giving superb performance in areas of high humidity and electrical stress. RCAB boots work in combination with all Raychem termination product lines, including both elastomeric and traditional heatshrink technology. RCAB boots are quick and easy to install and do not require any taping of the bushing or the termination. The boot can easily be removed and reinstalled without the need for additional material or tooling, allowing access to the bushing connection for test purposes. MEDIUM VOLTAGE CABLE ACCESSORIES Features & Benefits 36 • • • • • • • Simple and easy installation Tool free application High-performance insulation material Excellent track and erosion resistance Removable and reinstallable Unlimited shelf life Connection can be energised immediately after installation. R C A B fa m ily R C A B rig ht a ng le o r inline a pplic atio n up to 17.5 k V Duyen Ha Power Equipment Co.,Ltd R C A B inline a pplic atio n fo r 24 k V Description RCAB 4110 RCAB 4120 RCAB 5120 Max .system voltage U m B asic im pulse level C ollar siz e B ushing diam eter B ushing ty pes: to D IN , C E N E L E C , A N S I C able c ross sec tion 17.5 kV 9 5 kV N o.1 31~4 5 m m 35~4 0 0 m m 2 17.5 kV 9 5 kV N one 4 6 ~70 m m 4 0 0 / 6 30 A 35~4 0 0 m m 2 24 kV 125 kV 4 6 ~6 1 m m 4 0 0 / 6 30 A 35~30 0 m m 2 R e late d te st re po rts Reference No. Voltage (kV) Specification P P R -1336 P P R -138 3 17.5 24 C E N E L E C H D 6 29 .1 Duyen Ha Power Equipment Co.,Ltd MEDIUM VOLTAGE CABLE ACCESSORIES R ating & S pe c ifi c atio n 37 Elbows & Accessories RPIT Inner cone connector up to 52 kV, 1250 A General Description Raychem RPIT is an inner cone cable connector made of silicone rubber for cable connection to MV equipments, such as switchgear, ring main units and transformer up to 52 kV. The termination profile and interface are in accordance to EN 50180 and EN 50181 for inner cone connections. The contact parts are designed for circular stranded aluminium or copper conductors in accordance to IEC 60228. The basic construction of the mating termination follows well known design principles and incorporates a lamellate contact system which ensures reliable current transmission via a cone clamp to the conductor. The interface between the silicone body of the termination and the bushing is kept permanently sealed via the pressure of a spring between the insulator and the flange of the termination cover. The area between the termination flange and the cable is sealed against ingress of moisture with heat-shrink tubing. Features & Benefits MEDIUM VOLTAGE CABLE ACCESSORIES • Separable inline connection for high current, gas insulated switchgear up to 52 kV. • Termination mating interface in accordance to EN 50180 and EN 50181 for inner cone connections. • The contact parts are designed for circular stranded aluminium or copper conductors according to IEC-60228. • The connectors have been tested in accordance with the international specifications (e.g. IEC 60502-4, GB 12706.4). • Operating voltage up to 52 kV, nominal current up to 1250 A. 2 • Cable coverage up to 630 mm . 38 D e sig n & C o nstruc tio n B ushing pa rts 1. C onduc tor 2. E poxy resin 3. Hexagon soc ket head c ap sc rew s 4 . G asket C a ble Te rm inatio n pa rts 5. P lug 6 . W edge 7. S topper ring 8 . P re-m oulded stress cone 9 . Hexagon soc ket head c ap sc rew s 10 . P rotec tion cover 11. W ater proofing layer 12. Test lead Duyen Ha Power Equipment Co.,Ltd R ating & S pe c ifi c atio n Item Max .operating voltage U m N om inal c urrent I N C onduc tor X L P E dia. R ange of c able siz e R ated power frequenc y w ithstand voltage R ated im pulse w ithstand voltage P artial disc harge R ated short-c irc uit c urrent kV A mm2 mm kV / 5m in kV / ± 10 tim es 1.73U o ( pC ) kA Size 2 Size 3 Size 3 42 80 0 Max . 4 0 0 Max . 36 .5 117 20 0 ≤5 50 42 1250 Max . 6 30 Max . 50 117 20 0 ≤5 50 52 1250 Max . 6 30 Max . 50 124 250 ≤5 50 Description Cross-section (mm) Dia.over Insulation (mm) R P IT-1-730 5-C N ( 0 3) R P IT-1-7370 -C N ( 0 3) R P IT-1-739 5-C N ( 0 3) R P IT-1-7312-C N ( 0 3) R P IT-1-7315-C N ( 0 3) R P IT-1-7318 -C N ( 0 3) R P IT-1-7324 -C N ( 0 3) R P IT-1-7330 -C N ( 0 3) R P IT-1-734 0 -C N ( 0 3) R P IT-1-7350 -C N ( 0 3) R P IT-1-730 5 R P IT-1-7370 R P IT-1-739 5 R P IT-1-7312 R P IT-1-7315 R P IT-1-7318 R P IT-1-7324 R P IT-1-7330 R P IT-1-734 0 R P IT-1-7350 R P IT-1-736 3 R P IT-1-6 30 5 R P IT-1-6 370 R P IT-1-6 39 5 R P IT-1-6 312 R P IT-1-6 315 R P IT-1-6 318 R P IT-1-6 324 R P IT-1-6 330 R P IT-1-6 34 0 R P IT-1-6 350 R P IT-1-6 36 3 R P IT-1-5312 R P IT-1-5315 R P IT-1-5318 R P IT-1-5 324 R P IT-1-5330 R P IT-1-534 0 R P IT-1-5350 R P IT-1-536 3 50 70 95 120 150 18 5 24 0 30 0 400 50 0 50 70 95 120 150 18 5 24 0 30 0 400 50 0 6 30 50 70 95 120 150 18 5 24 0 30 0 400 50 0 6 30 120 150 18 5 24 0 30 0 400 50 0 6 30 29 .0 ~32.0 32.0 ~35.0 32.0 ~35.0 35.0 ~37.5 35.0 ~37.5 37.5~4 0 .0 4 0 .0 ~4 2.5 4 2.5~4 5.0 4 5.0 ~4 7.5 4 7.0 ~50 .0 26 .0 ~29 .0 28 .0 ~31.0 29 .0 ~32.0 29 .0 ~32.0 32.0 ~35.0 32.0 ~35.0 35.0 ~37.5 37.5~4 0 .0 4 2.5~4 5.0 4 5.0 ~4 7.5 4 7.0 ~50 .0 25.0 ~28 .0 26 .0 ~29 .0 28 .0 ~31.0 29 .0 ~32.0 3 2.0 ~35.0 32.0 ~35.0 35.0 ~37.5 37.5~4 0 .0 4 0 .0 ~4 2.5 4 2.5~4 5.0 4 7.0 ~50 .0 25.0 ~28 .0 26 .0 ~29 .0 28 .0 ~31.0 29 .0 ~32.0 32.0 ~35.0 35.0 ~37.5 37.5~4 0 .0 4 2.5~4 5.0 R P IT-1-3324 R P IT-1-3330 R P IT-1-334 0 R P IT-1-3350 R P IT-1-336 3 24 0 30 0 400 50 0 6 30 26 .0 ~29 .0 28 .0 ~31.0 29 .0 ~32.0 32.0 ~35.0 35.0 ~37.5 S e le c tio n Info rm atio n: d im e nsio ns show n in m illim e te rs Size 2 Voltage Level 20 .8 / 36 ( 4 2) kV ( IE C ) 19 / 33 ( 36 ) kV ( IE C ) 12/ 20 ( 24 ) kV ( IE C ) 6 / 10 ( 12) kV ( IE C ) Description Cross-section (mm) R P IT-1-720 5-C N R P IT-1-7270 -C N R P IT-1-729 5-C N R P IT-1-7212-C N R P IT-1-7215-C N R P IT-1-7218 -C N R P IT-1-7224 -C N 50 70 95 120 150 18 5 24 0 30 .0 ~33.0 30 .0 ~33.0 33.0 ~36 .0 33.0 ~36 .0 35.5~38 .0 37.5~4 0 .0 4 0 .0 ~4 2.0 R P IT-1-720 5 R P IT-1-7270 R P IT-1-729 5 R P IT-1-7212 R P IT-1-7215 R P IT-1-7218 R P IT-1-7224 R P IT-1-7230 50 70 95 120 150 18 5 24 0 30 0 26 .5~30 .0 26 .5~30 .0 30 .0 ~33.0 30 .0 ~33.0 33.0 ~36 .0 33.0 ~36 .0 35.5~38 .0 37.5~4 0 .0 R P IT-1-6 20 5 R P IT-1-6 270 R P IT-1-6 29 5 R P IT-1-6 212 R P IT-1-6 215 R P IT-1-6 218 R P IT-1-6 224 R P IT-1-6 230 50 70 95 120 150 18 5 24 0 30 0 23.5~26 .5 26 .5~30 .0 26 .5~30 .0 30 .0 ~33.0 30 .0 ~33.0 33.0 ~36 .0 35.5~38 .0 37.5~4 0 .0 R P IT-1-520 5 R P IT-1-5270 R P IT-1-529 5 R P IT-1-5212 R P IT-1-5215 R P IT-1-5218 R P IT-1-5224 R P IT-1-5230 R P IT-1-524 0 R P IT-1-5250 R P IT-1-3212 R P IT-1-3215 R P IT-1-3218 R P IT-1-3224 R P IT-1-3230 R P IT-1-324 0 R P IT-1-3250 R P IT-1-326 3 50 70 95 120 150 18 5 24 0 30 0 400 50 0 120 150 18 5 24 0 30 0 400 50 0 6 30 19 .5~22.5 21.0 ~24 .0 23.5~26 .5 23.5~26 .5 26 .5~30 .0 26 .5~30 .0 30 .0 ~33.0 30 .0 ~33.0 33.0 ~36 .0 37.5~4 0 .0 19 .5~22.5 21.0 ~24 .0 23.5~26 .5 23.5~26 .5 26 .5~30 .0 30 .0 ~33.0 33.0 ~36 .0 35.5~38 .0 MEDIUM VOLTAGE CABLE ACCESSORIES 26 / 35 ( 4 0 .5) kV (GB ) Size 3 Dia.over Insulation (mm) For cables manufactured to specifications other than GB and IEC standards, please contact our local sales representative to better assist your selection. Duyen Ha Power Equipment Co.,Ltd 39 There are various options for cables with different type of metallic shields. The Voltage Detection (VD) function can be also equipped in response to customer's demands. R P IT-1-x x x x-T R P IT-1-x x x x-W R P IT-1-x x x x-V D -T R P IT-1-x x x x-V D -W F or c ables w ith copper tape sc reen F or c ables w ith copper w ire sc reen W ith voltage detec tor, for c ables w ith copper tape sc reen W ith voltage detec tor, for c ables w ith copper w ire sc reen Inne r C o ne B ushing up to 52 k V 12 5 0 A C a pa c itive vo lta g e ta pe o f bushing w ith te st po int Size 2 (800A) 3 (1250A) C apac itive voltage tap 8 ± 2 pF 8 ± 2 pF D im e nsio n Size 2 (800A) 3 (1250A) A B C 50 14 0 14 58 218 12.5 MEDIUM VOLTAGE CABLE ACCESSORIES Insulate d c a p 40 D im e nsio n Size 2 (800A) 3 (1250A) A B C 38 131 10 2 54 20 0 130 Duyen Ha Power Equipment Co.,Ltd Insulate d so c ke t D im e nsio n 2# RPIT-2-IS 3# RPIT-3-IS A B C 20 0 132 10 2 235 16 0 130 C ha ra c te ristic Item A C voltage w ithstand P artial D isc harge B IL 9 5 kV, 1 m in 4 5 kV, < 10 pC 20 0 kV Insta llatio n To o ls Metal tool case including an easy to handle compression tool for wedge and contact ring and all necessary adaption rings. R e late d te st re po rts Reference No. Voltage (kV) Specification C T 10 -128 1 C T 11-170 0 -1/ 2/ 3 C T 11-2739 -1 & 2 C T 11-38 28 -1 & 2 20 11J D L 4 73 20 11J D L 570 52 52 52 42 42 42 G B / T 1270 6 .4 -20 0 8 IE C 6 0 50 2.4 -20 0 5 Duyen Ha Power Equipment Co.,Ltd MEDIUM VOLTAGE CABLE ACCESSORIES Size 41 ABOUT TE CONNECTIVITY TE C o nne c tivity (N Y S E: TEL) is a $13 billion w orld le ade r in c o nne c tivit y. T he c ompa ny designs and manu factu res products at the heart of elect ronic c o nn ec tio ns f or th e w o r ld ’ s leading ind u s tries incl u di ng a u to moti v e , ene rgy and indu s trial, b ro adband c ommunic a ti o ns , c o ns u mer d e vi c es , hea lthca re, an d ae rosp a c e an d de fens e. TE C on nectivity ’ s lon g- sta ndi ng c ommitm ent to inn ovatio n and engin eering exc ell en c e helps its cu stom ers sol ve the need for mo re ene rgy c ienc y, al way s-on c ommuni c atio ns and ev er-inc re a si ng p roductivit y. W it h ne a rly 9 0 ,0 0 0 empl oy ee s in ov e r 5 0 c ountries , TE C on nec tivity m akes c on nections the w orld relies o n to w or k fl awle ssly every d ay. To c onnect with the c ompan y, visit: ww w.TE .c om. W hile TE C onnec tivity ( TE ) ha s m ade every reaso nabl e e ort to ensu re the acc urac y of the inform ation in this c atalog, T E does not guaran tee that it is er ror -f ree, nor do es TE m ake any oth er represen tation, war ran ty or gua rantee th at the infor m ation is acc urate, cor rect, reliable or cu rrent. T E rese rves th e right to ma ke any adj ustm en ts to the inform ation con taine d herein at any time w ithou t notice. TE exp ressly dis c laims all impli ed war ran ties rega rding the inform ation contained herein, includi ng, but not limi ted to, any impli ed warranties of m erchan tability or fitn ess for a pa rticu lar pu rpose. T he dim en sio ns in this c atalog are for referen ce purposes only and are subject to c hang e wit hout noti ce. S pec ifi c atio ns are subj ec t to chan ge w ithou t noti ce. C onsult TE for t he l atest dim en si on s and d esign sp ec ifi c atio ns. R ayche m, R ayc hem (log o), T E C onn ectivity and T E connectivity (log o) a re t radem ar ks . T E E ne rg y – innova ti ve and e c o no m ic a l s o lutio ns fo r the e le c trical p ow er indu stry: cable a cc e ssories, c onnec to rs & fi tting s , ins ul ators & in sul ation, s urge a rresters, sw itc hing eq uipment, street lighting, pow er measurement and cont rol . SHANGHAI OFFICE TE Shanghai Technology P ark - South Building N o. 3 0 7, Qin Jiang R oad, Caohejing Hi-Tech P ark Shanghai 200233 P. R. of China Tel: +86- 0 21-6 106 7000 F ax: +86- 0 21-6 4 9 56686 Tyc o Elect ronics Japan G.K. Ene rgy Division 3816 Nobori to, Tama- ku, K aw asaki, K anagaw a, 2148 533, Japan Tel: 81-44-900-5106 F ax: 81-44-900-5144 C ell: 81-80 -34 17-8 9 0 1 C ontact P erson : Nobuo W atanabe Tyc o E le c tronics R aychem K o rea L td. 5th.Fl.,Seocho Bldg, 136510 Seocho-Dong, SeochoK u, Seoul, K orea 13 7-0 70 Tel. +82-2 -34 15-46 27 F ax. + 82-2-3486 -1788 Mobile: +82-10- 8 988-46 27 c ontact person: Yeon Soo Jung Duyen Ha Power Equipment Co.,Ltd Hotline: 0904 280 272 / 0972 280 272 Website: dienlucduyenha.com.vn TE C onnectivity HK Limi ted R oom 6 15-62 0 , 6 / F, N o. 1 Hung To R oad, K wun Tong, K owloon. Tel: +8 52- 2790 9625 F ax: +8 52- 2735 48 27 C ontact P erson: K ester Shum, Nelson L ee Tyc o Elect ronics Singapore P te L td N o.26 Ang Mo Kio Industrial P ark 2 Singapo re 5 6 9 50 7 Tel: +656 59051 57 (Raychem) Tel: +656 5905151 ( Cromp ton) F ax: +6564818254 C ontact person: Mr. Senjaya Halim C ontact person: Mr. Anthony Ho C.K. ( C romp ton Asia) TE Connectivity Vietnam Duyen Ha Power Equipment Co.,Ltd Ngu Hiep ward, Thanh Tri District, Hanoi City. Tel: +844 3 682 5517 Fax: +844 3 682 5517 Mobile: 0904.28.02.72 Contact: Mr. Pham Van Ha Email: dienlucduyenha@gmail.com
0
You can add this document to your study collection(s)
Sign in Available only to authorized usersYou can add this document to your saved list
Sign in Available only to authorized users(For complaints, use another form )