Measurement
:m
M80
DI8
MIO
pr:855-ZS-2023A.I
2 : 2 : 10 : 3
Address
ELECTRIC CENTRE
pr:855-M1-2023L.F:DIR1
DIR.CHANGE Forward
pr:855-M1-2023L.F:DIR2
DIR.CHANGE Backward
15ccob
in
out
mode=0
pr:855-M1-2023.F
Name
14
o
>
=
1
48
M42_SD
Package
OP01
80
Execution 100
Order
ms
DIR
a
ma
ron
rof
mac
fon
85ccob
out
mode=0
Customer
Module version: 1.5
ldc
dlc
amc
62ccob
in
out
mode=0
64ccob
out
mode=0
in
90ccob
in
out
mode=0
in
in
65ccob
in
out
mode=0
70ccob
in
out
mode=0
75ccob
in
out
mode=0
80ccob
out
mode=0
55ccob
cnd m=0 out
in=1
60ccob
cnd m=0 out
in=0
50ccob
cnd m=0 out
in=0
45ccob
cnd m=0 out
in=1
41ccob
cnd m=0 out
in=0
42ccob
cnd m=0 out
in=1
FROM LOGIC/INTERLOCKING MODULE
DIR1
DIR2
:bv 46
on
o
o &
ron
dna
pr:855-M1-2023L.F:ASTART
AUTOMATIC START
pr:855-M1-2023L.F:ASTOP
AUTOMATIC STOP
pr:855-M1-2023L.F:A
TO AUTO
pr:855-M1-2023L.F:M
TO MANUAL
pr:855-M1-2023L.F:RON
RELEASE STARTING
pr:855-M1-2023L.F:ROFF
RELEASE STOPPING
pr:855-M1-2023L.F:FON
FORCE START
pr:855-M1-2023L.F:FOFF
FORCE STOP
pr:855-M1-2023L.F:MAC
MANUAL TO AUTO ENABLED
pr:855-M1-2023L.F:AMC
AUTO TO MANUAL ENABLED
pr:855-M1-2023L.F:DLC
M/L CHANGE ALLOWED
pr:855-M1-2023L.F:LDC
L/M CHANGE ALLOWED
Design Members:
M42_SD
Planner
11-05-01 12:00
Application version: TRESLIB 2.0
Modification
25-04-29 19:28
0 = Forward
1 = Backward
bin
*
pr:855-M1-2023.D
DIRECTION CHANGE
0@
bin
PD5
MCS
Trim squirt
pr:1252-M1-0543.D
1252-M1-0543L
1252-M1-0543_SIM
gd:B1:mcs:Trim_squirt
Department
DIR
150 ccob
in
out
in
101
ccout
cnd
fmask= 254
mode = 4
140 ccob
out
>
=
1
cnd
fmask= 254
mode = 0
ccout
DIRECTION CHANGE IS POSSIBLE
ONLY AFTER MOTOR HAS BEEN STOPPED
FOR 0.1 SECONDS!!!
MOTOR CURRENT LOGIC
96 pls
pbout
cntrl
pl
mode= PULSE
uds = DOWN
ssta= 0
&
598
1
597
&
>
=
o 596
599
o >= 1
0,0.1@
onb
fof
1
91
>
=
ins
IF WAITING TIME IS RUNNING MOTOR START IS NOT POSSIBLE
DIR1
D_OUT
D_OUT
DIR2
Trim Squirt DS
Positioning
Loop name
231
Electrical center:
855-M1-2023
Tag
mtr
mtr
*
pr:855-M1-2023
600 mtr2
mtr*
offb
off
on
a
onb
l
ma
m
a
ins
ma
rof
ron
e1
foff
fon
roff
ron
wd
curhha
curha
toaon
foffe
fone
ld
fon
e2
on
160 ccob
out
ccout
in
cnd
in
cnd
fmask= 254
mode = 0
170 ccob
out
fmask= 254
mode = 0
ccout
610 ccobo
in
out
out2
out1
630 dosbo
in
620 ccobo
in
out
bse
1
0
pr:1252-M1-0543
:e1 1252-XZ3-0542L
:ins 1252-M1-0543L
:ma 1252-M1-0543L
:off:bv 1252-M1-0543L
:on:bv 1252-M1-0543L
Feedback
Control
M80
DO8
MIO
pr:855-ZY-2023C.O
2 : 2 : 14 : 5
:cb
Address
:c
Backward
Control
wdd
amc
mac
:cb
Address
:c
Feedback
Control
D_OUT
0,0
0,0
Feedback
M80
DO8
MIO
pr:855-ZY-2023B.O
2 : 2 : 14 : 4
:cb
Address
:c
Forward
e4
mac
disa
ldc
onb
1
86
>
=
e5
dlc
M80
DO8
MIO
pr:855-ZY-2023A.O
2 : 2 : 14 : 3
e6
amc
921 am2
ma
ins
:INS
0
:INS
1252-M1-0543_SIM
1252-PY2-0542
Address
:c
Control
0-100 %
Feedback
:REF
:REF
No references
SPEED CONTROL
Scale and
unit
:cb
M80
AO4H
pr:855-ZX-2023.O
2 : 2 : 4 : 2
MIO
No references
:CUR
:MA
No references
:MA
0
:STR
START/STOP
ldc
insfa
ton = 4.0@ s
toff= 4.0@ s
puls = 8
insmask
dlc
*
am
cur
am2
curh
904ccoa
in
out
mode=0
av
pr:855-M1-2023.REF
am2
curhh
s
fof
e3
0@
0,0@
pr:855-M1-2023L.F:REF
speedsp
MOTOR SPEED REFERENCE
Page 1 / 1