MINI-LINK TN R4 System Description MINI-LINK TN System Description • Magazine (AMM) • Power Filter Unit • Fan • Node Processor Unit • Line Termination Unit • Ethernet Termination Unit • Modem Unit © Ericsson AB 2007 LZU 108 6895 R1A Figure 1- 1 MINI-LINK TN System Description Access Module Magazines Diffrent sizes depending on the need © Ericsson AB 2007 LZU 108 6895 R1A Figure 1- 2 MINI-LINK TN System Description Access Module Magazine, AMM AMM 2p (previous release) • For edge and repeater nodes • Can house 2 full width plug-in units and 2 half width plug-in units • Maximum 2 radio terminals AMM 2pB (Now) • For edge and repeater nodes • Can house 2 full width plug-in units and 2 half width plug-in units • Maximum 2 radio terminals • Redundant DC-power directly connected to the magazine © Ericsson AB 2007 LZU 108 6895 R1A Figure 1- 3 MINI-LINK TN System Description AMM 2p B, slots Reserved slots: • 01: NPU3, NPU3 B Configuration rules: NPU3 or NPU3 B Fan Unit FAU4 • Slot 00 is a HSU slot available for any half size PIU except NPU • Slot 02 and 03 are available for any full size PIU • Note that the DC power is connected to the magazine and not to a plug-in unit © Ericsson AB 2007 LZU 108 6895 R1A Slot 01 Slot 03 Slot 00 Slot 02 Redundant DC power +24 or -48VDC Figure 1- 4 MINI-LINK TN System Description Access Module Magazine, AMM AMM 6p (previous release) • For medium sized aggregation nodes • Can house 6 full width plug-in units • Maximum 5 radio terminals AMM 6p B • For medium sized aggregation nodes • Can house 6 full width plug-in units • Maximum 5 radio terminals • Redundant DC-power © Ericsson AB 2007 LZU 108 6895 R1A Figure 1- 5 MINI-LINK TN System Description Access Module Magazine, AMM AMM 6p C (Now) • For medium sized aggregation nodes • Can house 5 full width plug-in units and 2 half width plug-in units • Maximum 5 radio terminals • Redundant DC-power AMM 6p D • For medium sized aggregation nodes • Can house 4 full width plug-in units and 4 half width plug-in units • Maximum 4 radio terminals • Redundant DC-power © Ericsson AB 2007 LZU 108 6895 R1A Figure 1- 6 MINI-LINK TN System Description AMM 6p C, slots Reserved slots: • 00 and 01: PFU3 B • FAU: FAU2 • 07: NPU3, NPU3 B Slot 01 FAU slot Slot 08 Configuration rules: Slot 06 Slot 05 Slot 04 Slot 03 • All 1+1 configurations starts at slot number 2 and 4 • Dual pol. w XPIC starting at slot number 2 and 4 • DC power +24 or -48VDC © Ericsson AB 2007 LZU 108 6895 R1A Slot 07 Slot 02 Slot 00 Figure 1- 7 MINI-LINK TN System Description Access Module Magazine, AMM AMM 20p • For large sized aggregation nodes • Can house 20 full height plug-in units • Maximum 18 radio terminals • Redundant DC-power © Ericsson AB 2007 LZU 108 6895 R1A Figure 1- 8 MINI-LINK TN System Description AMM 20p B (Now) Fan unit AMM 20p B • Large sized aggregation nodes • 20 full size plug-in units Max. 19 radio terminals • Redundant DC-power, 48VDC Cable shelf / air slot © Ericsson AB 2007 LZU 108 6895 R1A Figure 1- 9 MINI-LINK TN System Description AMM 20p B, slots Reserved slots: Slot 01 • 00 and 01: PFU1 • 11: NPU1 B, NPU1 C Configuration rules: • 1+1starting at even numbered slots except slot 10 • Dual pol. w XPIC starting at even numbered slots except slot 10 • DC power -48VDC Slot 00 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 ”4 group” ”4 group” © Ericsson AB 2007 LZU 108 6895 R1A Figure 1- 10 MINI-LINK TN System Description ”4 group” ”4 group” MINI-LINK TN System Description • Magazine (AMM) • Power Filter Unit • Fan • Node Processor Unit • Line Termination Unit • Ethernet Termination Unit • Modem Unit © Ericsson AB 2007 LZU 108 6895 R1A Figure 1- 11 MINI-LINK TN System Description Power Filter Units, PFU • DC power distribution to the magazine. • DC filtering • Short circuit, polarity and under voltage protection • One unit is mandatory per magazine, one extra can be added for DC redundancy • Redundant PFU function is embedded directly in the AMM 2p B © Ericsson AB 2007 LZU 108 6895 R1A Figure 1- 12 MINI-LINK TN System Description PFU1, PFU3 B PFU1 • AMM 20p B • Dedicated slots, 00 and 01 • -48VDC supply voltage • Optional two units for DC redundancy • Alarm interconnection for the Fan unit PFU3 B • AMM 6p C, AMM 6p D • Dedicated slots, 00 and 01 • +24 or -48VDC supply voltage • Optional two units for DC redundancy © Ericsson AB 2007 LZU 108 6895 R1A Figure 1- 13 MINI-LINK TN System Description MINI-LINK TN System Description • Magazine (AMM) • Power Filter Unit • Fan • Node Processor Unit • Line Termination Unit • Ethernet Termination Unit • Modem Unit © Ericsson AB 2007 LZU 108 6895 R1A Figure 1- 14 MINI-LINK TN System Description AMM 2p B, FAU4 FAU4 Air out Air in AMM 2p B is equipped with a FAU4 depending on the total power dissipation in the AMM. © Ericsson AB 2007 LZU 108 6895 R1A Figure 1- 15 MINI-LINK TN System Description AMM 6p C and D, FAU2 Air out Air in FAU2 • Fan unit FAU2 is mandatory in all 6p magazines. • At least 30 mm free space behind the magazine is needed for sufficient airflow. • If the space is less than 30 mm, a free space of 1U should be free above the magazine. • All unused slots shall be covered by dummy fronts. © Ericsson AB 2007 LZU 108 6895 R1A Figure 1- 16 MINI-LINK TN System Description AMM 20p B, FAU1 • AMM 20p B • Mandatory unit • Three blowers for redundancy • Redundant DC power • Fan alarm interconnection to PFU1 © Ericsson AB 2007 LZU 108 6895 R1A Figure 1- 17 MINI-LINK TN System Description MINI-LINK TN System Description • Magazine (AMM) • Power Filter Unit • Fan • Node Processor Unit • Line Termination Unit • Ethernet Termination Unit • Modem Unit © Ericsson AB 2007 LZU 108 6895 R1A Figure 1- 18 MINI-LINK TN System Description Node Processor Unit, NPU Common functionalities • Central node processor • Mandatory plug-in unit • Holds configuration and licenses for the node in Non-volatile memory and Removable Memory Module • LAN interface for management DCN • USB for local maintenance • IP router for the management DCN • SNMP agent • E1/DS1 Line termination interfaces © Ericsson AB 2007 LZU 108 6895 R1A Figure 1- 19 MINI-LINK TN System Description Node Processor units NPU1 B LAN NPU1 C NPU1 C USB, local maintenance F P O&M USB, local maintenance TR:7/LAN TR:6 4XE1 3 user in, 3 user out 1000BASE-TX OUT TR:5 IN OUT TR:4 IN 4XE1 4XE1 LAN alt 3 user in, 3 user out Eth. traffic TR:4A-4D/User Out:E-F 10/100BASE-T 10/100BASE-T F P TR:3 LAN O&M NPU3 B NPU3 B E1/DS1 TR:4A-4D/User Out:E-F 10/100/1000BASE-T 10/100/1000BASE-T F P TR:3 TR:2/LAN O&M LAN 4XE1, 2 user out Eth. traffic USB LAN alt 4XE1, 2 user out Eth. traffic © Ericsson AB 2007 LZU 108 6895 R1A Figure 1- 20 MINI-LINK TN System Description BR E1/DS1 BR NPU3 NPU3 10/100/1000BASE-T 10/100/1000BASE-T1000BASE-TX 4XE1 USB MINI-LINK TN System Description • Magazine (AMM) • Power Filter Unit • Fan • Node Processor Unit • Line Termination Unit • Ethernet Termination Unit • Modem Unit © Ericsson AB 2007 LZU 108 6895 R1A Figure 1- 21 MINI-LINK TN System Description Line Termination Unit, LTU Traffic interfaces E1/E2/E3/DS1/DS3/STM-1/OC-3 To terminate traffic to/from external equipment © Ericsson AB 2007 LZU 108 6895 R1A Figure 1- 22 MINI-LINK TN System Description Line termination units, PDH LTU3 12/1 Soffix connectors, 4 E1’s to each LTU 16/1 LTU 32/1 © Ericsson AB 2007 LZU 108 6895 R1A Figure 1- 23 MINI-LINK TN System Description Line protection, SDH LTU 155 Same traffic over two optical connections Alarms Fibre Alarms BPI bus © Ericsson AB 2007 LZU 108 6895 R1A Figure 1- 24 MINI-LINK TN System Description TDM bus TDM bus 2x Line Termination units LTU 155 e/o, LTU B 155 or LTU 155 ANSI (1+1 APS) Line Termination Unit, SDH LTU 155e or LTU155 e/o • Terminates one STM-1 connection with 63xE1 in the backplane. • Electrical interface (G.703) • Optical interface (Short haul S-1.1) © Ericsson AB 2007 LZU 108 6895 R1A Figure 1- 25 MINI-LINK TN System Description MINI-LINK TN System Description • Magazine (AMM) • Power Filter Unit • Fan • Node Processor Unit • Line Termination Unit • Ethernet Termination Unit • Modem Unit © Ericsson AB 2007 LZU 108 6895 R1A Figure 1- 26 MINI-LINK TN System Description Ethernet Termination Unit, ETU ETU3 ETU3 10/100/1000BASE-T ETU2 ETU2 for Ethernet traffic termination in any magazine • Multi-port Ethernet plug in board • 5 x 10/100BASE-T interface • 1 x 10/100/1000BASE-T interface • 180 Mbit/s throughput © Ericsson AB 2007 LZU 108 6895 R1A Figure 1- 27 MINI-LINK TN System Description MINI-LINK TN System Description • Magazine (AMM) • Power Filter Unit • Fan • Node Processor Unit • Line Termination Unit • Ethernet Termination Unit • Modem Unit © Ericsson AB 2007 LZU 108 6895 R1A Figure 1- 28 MINI-LINK TN System Description Modem Unit, (MMU) • Interface to the radio (One MMU per radio). • Modulates the digital traffic into analogue radio-modulation • Sets the traffic capacity and frequency bandwidth • Compact 1+1 configuration • MSP 1+1 support (MMU2 E,F) • SFP for traffic termination (MMU2 E,F) • Supports XPIC (MMU2 F,H). • Supports Adaptive Modulation. © Ericsson AB 2007 LZU 108 6895 R1A Figure 1- 29 MINI-LINK TN System Description Modem units General about SDH/Sonet types MMU2 F 155 STM-1 OUT TR IN XPIC Modem MMU2E and MMU2F where XPIC is the different © Ericsson AB 2007 LZU 108 6895 R1A Figure 1- 30 MINI-LINK TN System Description Modem Unit, MMU Small Form-factor Pluggable SFP: • User selectable interface module to insert in MMU2 E and MMU2 F • Optical interface (Short haul S-1.1) • Electrical interface (G.703) © Ericsson AB 2007 LZU 108 6895 R1A Figure 1- 31 MINI-LINK TN System Description Modem Unit, MMU (R3) C-QPSK 16 QAM 128 QAM 2x2 4x2 8x2 17x2 8x2 17x2 22x2 32x2 46x2 35x2 75x2 16/64 QAM 128 QAM 155 155 MMU2 B MMU2 C MMU2 D MMU2 E MMU2 F* * with XPIC available with 128 QAM © Ericsson AB 2007 LZU 108 6895 R1A Figure 1- 32 MINI-LINK TN System Description MMU Types (R4) ▪ PDH Only:- MMU 2B and MMU 2C. ▪ SDH Only:- MMU 2E and MMU 2F. ▪ Super PDH and Ethernet:- MMU 2D and MMU 2H – The Channel Spacing and Modulation Techniques are set to give a total traffic capacity. – This Total Traffic Capacity can be divided into (E1s) and Packet Link Capacity. © Ericsson AB 2007 LZU 108 6895 R1A Figure 1- 33 MINI-LINK TN System Description MMU2 H Traffic capacities – XPIC & adaptive modulation Bandwidth Modulation TN Capacity Mbps 7 MHz 14 MHz 28 MHz 40 MHz 56 MHz 4 QAM 10 21 46 65 94 16 QAM 21 45 94 133 189 32 QAM 25 54 115 167 237 64 QAM 29 66 138 197 285 128 QAM 35 72 160 229 326 256 QAM 41* ** 78 180 257 369 512 QAM 50* ** 95* ** 200* 286 406 Physical modes planned to be available with XPIC before and including release 4.4 Physical modes that can combine XPIC and AM planned before and including release 4.4 Mix Native Ethernet and Native PDH in steps of 2 Mbps Stated Capacity are:1) 406 Mbps air interface capacity 2) 500 Mbps line interface capacity * Requires new HW revision state of MMU2 H planned for 4.4 ** Not available for 26, 28, 32, 38 and 42 GHz bands MIX Adaptive Modulation and XPIC Secure highest possible traffic capacity © Ericsson AB 2007 LZU 108 6895 R1A Figure 1- 34 MINI-LINK TN System Description © Ericsson AB 2007 LZU 108 6895 R1A Figure 1- 35 MINI-LINK TN System Description
0
You can add this document to your study collection(s)
Sign in Available only to authorized usersYou can add this document to your saved list
Sign in Available only to authorized users(For complaints, use another form )