Project: Document No.: KKS - MASTERLIST STANDARD LH-DE011017-REV02 Standard HYDRO POWER PLANTS KKS - HANDBOOK Release „KKS - Handbook“ AT-DE AT Date / Mr. Dendl Date / Mr. Hassler All rights reserved. No part of these documents may be reproduced, copied, distributed, adapted or recorded in any form or by any means (by photocopying, microfilming or by any other technique) without the written permission of the VA TECH HYDRO GmbH. Furthermore, manufacturing and copying of the represented products, plants, systems and technical procedures are prohibited. Alle Rechte vorbehalten. Kein Teil dieser Unterlagen darf in irgendeiner Form (durch Photokopie, Mikrofilm oder ein anderes Verfahren) ohne schriftliche Genehmigung der VA TECH HYDRO GmbH reproduziert oder unter Verwendung elektronischer Systeme gespeichert, bearbeitet, vervielfältigt oder verbreitet werden. Ebenso ist jeder Nachbau bzw. jede Nachahmung von in diesen Unterlagen beschriebenen Geräten, Anlagen, Systemen, Verfahren ua. verboten. Copyright © 2001 VA TECH HYDRO GmbH AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 1/124 Project: Document No.: KKS - MASTERLIST STANDARD LH-DE011017-REV02 DOCUMENT HISTORY Date of issue Revision Revised pages Type of revision 17.10.2001 00 First issue First issue 14.02.2003 REV01 41, 102 Designation letter YP und YR added. 27.11.2006 REV02 all Formats, insert VGB guidelines Contents list Part I: KKS: Structure and application 3 Part II: KKS – Master list 65 AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 2/124 Project: Document No.: KKS - MASTERLIST STANDARD LH-DE011017-REV02 Part I: KKS: Structure and application Contents 1 INTRODUCTION ____________________________________________________________________________4 2 STRUCTURE OF KKS _______________________________________________________________________5 2.1 2.2 2.3 2.4 2.5 2.6 2.7 2.8 2.9 3 BREAKDOWN LEVELS ______________________________________________________________________5 BREAKDOWN LEVEL 0 – TOTAL PLANT_______________________________________________________6 BREAKDOWN LEVEL 1 – FUNCTION KEY _____________________________________________________7 BREAKDOWN LEVEL 2 – EQUIPMENT UNIT KEY_______________________________________________7 BREAKDOWN LEVEL 3 – COMPONENT KEY ___________________________________________________8 NOTATION OF BREAKDOWN LEVELS ___________________________________________________________8 NAMING OF THE BREAKDOWN LEVELS _________________________________________________________9 PREFIXES _______________________________________________________________________________10 VATECH STANDARD DESIGN _______________________________________________________________10 APPLICATION OF KKS _____________________________________________________________________11 3.1 PROCESS-RELATED IDENTIFICATION __________________________________________________________11 3.2 POINT OF INSTALLATION-IDENTIFICATION _____________________________________________________11 3.3 LOCATION IDENTIFICATION _________________________________________________________________12 3.4 IDENTIFICATION OF CONNECTIONS ___________________________________________________________12 3.5 IDENTIFICATION OF SIGNALS ________________________________________________________________12 3.6 IDENTIFICATION OF CABLES ________________________________________________________________13 3.7 IDENTIFICATION OF DOCUMENTS ____________________________________________________________15 3.8 EXAMPLE OF KKS APPLICATION _____________________________________________________________15 3.9 REGISTRATION IN GRAPHICAL SYMBOLS _______________________________________________________28 3.10 LOOPS WITH MULTIPLE PROBES AT ONE LOCATION _______________________________________________30 3.11 GATING OF LOOPS ________________________________________________________________________31 3.12 IDENTIFICATION OF LOOPS _________________________________________________________________32 3.12.1 Identification of direct loops ___________________________________________________________32 3.12.2 Identification of indirect loops__________________________________________________________34 4 EXTENDED KKS – KEY (STANDARD)________________________________________________________38 5 IDENTIFICATION OF C&I COMPONENTS ___________________________________________________40 5.1 SIGNAL IDENTIFICATION ___________________________________________________________________40 5.1.1 General Signal Identification _____________________________________________________________40 5.1.2 Designation letter for the signal range/application (Standard / Overview) _________________________41 5.2 BINARY SIGNALS (CONTACTS) AND LIMIT VALUES FROM SIGNAL CONDITIONING ________________________42 5.2.1 Designation letter (signal range) __________________________________________________________42 5.2.2 Signal numbers for binary process signals (contacts) __________________________________________42 5.2.3 Signal numbers for limit values derived from analog process signals _____________________________42 6 EXPLANATIONS FOR HYDRO POWER PLANTS FROM VGB-D1 _______________________________44 6.1 IDENTIFICATION OF BREAKDOWN LEVEL 1 _________________________________________________________44 6.1.1 Identification mechanical __________________________________________________________________44 6.1.2 Identification electrical ___________________________________________________________________56 6.2 IDENTIFICATION OF BREAKDOWN LEVEL 2 _________________________________________________________60 6.3 IDENTIFICATION OF BREAKDOWN LEVEL 3 _________________________________________________________63 7 INTEGRATION OF GE (GENERAL ELECTRICS) IDENTIFICATION SYSTEM IN KKS ____________64 AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 3/124 KKS - MASTERLIST 1 Project: Document No.: STANDARD LH-DE011017-REV02 INTRODUCTION The design of complex technical plants involves an enormous number of data to be exchanged between the parties concerned. The identification of plant systems, sections and individual components therefore has to be centralised for the whole plant. The identification system provides a common language for the design and documentation of the scope of work and services. Due to their complexity, modern power stations, where civil works, mechanical- and electrical sections as well as electronic systems are related to each other, require an identification system to avoid disagreement between the parties and unforeseeable costs and time delays during construction. The identification system KKS (Kraftwerks-Kennzeichen-System) represents a technological and logical classification for modern power stations. All plant sections and components will be identified on a system-related basis in order to satisfy the requirements of the manufacturer, plant owner and operators as well as experts in view of design, erection, operation and maintenance. KKS includes: - Design and construction Verification Assembly Manufacturing Erection Acceptance Documentation Operation Maintenance Recruiting and replacement administration Outage statistics Plant accounting Industrial economics The KKS identification system for power stations was developed by the KKS-workout involving designers, plant operators and power authority members and was published in two sections by the VGB-Verlag 1989: - KKS-Guidelines KKS-Key The 5th edition containing complements to the KKS-Key was published in 2003 by the VGB-Verlag publishing house. The indicated breakdown levels 1, 2, 3 in this document are those dated 2004. The Explanations for Hydro Power Plants VGB-B 106 D1 from July 2004 are included (see chapter 6). The KKS in its characteristics will be in accordance with IEC 61346, DIN EN 61346 and DIN 6779-10. The following information represents a general overview regarding the structure and use of KKS. The KKS-Key contained in part two will form a basic platform for utilising KKS for the sole internal use of VA TECH HYDRO GmbH for plants designed and executed by VA TECH HYDRO GmbH. AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 4/124 Project: Document No.: KKS - MASTERLIST 2 STANDARD LH-DE011017-REV02 STRUCTURE OF KKS 2.1 Breakdown Levels An individual identification code consists of a maximum of 4 breakdown levels: Breakdown level 0: Total Plant Breakdown level 1: Function Key Breakdown level 2: Equipment Unit Key Breakdown level 3: Component Example: Serial no. of breakdown level 0 1 2 3 Example Block System PumpUnit Drive The data characters are selected in accordance to the alphanumeric characters in the table below: A N () Alphabetic characters (roman letters except I and O, and special symbols) Numerical characters (Arabic numerals) The use of these data characters will be fixed project specific by VA TECH-HYDRO. Breakdown level 0 Designation of G F0 F1 data character Type of (A) (N) A data character (N) F2 1 F3 FN FN 2 A1 A2 AN AN AN A3 3 B1 B2 BN BN A A N A A N A N N N (A) A N N The data characters A have a bearing on classification. They are fixed in the KKS-Key. Permitted changes or additions to the KKS-Key must be agreed by the parties concerned and approved by VA TECH-HYDRO. The data characters N are used for counting. They are dependent on the project and will be fixed by VA TECH HYDRO. AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 5/124 Project: Document No.: KKS - MASTERLIST 2.2 STANDARD LH-DE011017-REV02 - Numbering starts new when one of the preceding code elements changes. - Redundant zeros must be written: correct wrong PAB01AA001 PAB10AA010 PAB1AA1 PAB10AA10 Breakdown level 0 – TOTAL PLANT 0 G (A) (N) 1 F0 F1 F2 F3 FN FN 2 A1 A2 AN AN AN AN 3 B1 B2 BN BN (N) A A A A A N N A N N N (A) A N N Describes the identification of all items of the power plant. Differentiation by A or N: - Power station units - Extensions or - Non-unit-specific plants This code is subject to agreement between the parties concerned with respect to: - Type of data character - Contents Example: Block A Block B Non-unit-specific plant Block C N Block free K Breakdown level 0 may be omitted if the code remains unique throughout the plant. AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 6/124 Project: Document No.: KKS - MASTERLIST 2.3 STANDARD LH-DE011017-REV02 Breakdown Level 1 – FUNCTION KEY 0 G (A) (N) 1 F0 F1 F2 F3 FN FN 2 A1 A2 AN AN AN AN 3 B1 B2 BN BN (N) A A A A A N N A N N N (A) A N N F0-(N) Prefix number F0 numbering of similar units and plants in view of the entire plant e.g. - several generator in a block - general component F1-A Main group F2-A Group F3-A Subgroup F1-3 Classification fixed as per KKS-Key for: - systems and plants - points of installation, e.g. switchboards - structures FN-N Counting numbers: - redundant zeros must be written - consecutive numbering or by groups - numbering starts new if F1-3 changes 2.4 Breakdown Level 2 – EQUIPMENT UNIT KEY 0 G (A) (N) 1 F0 F1 F2 F3 FN FN 2 A1 A2 AN AN AN AN 3 B1 B2 BN BN (N) A A A A A N N A N N N (A) A N N A1-A Main group A2-A Subgroup A1-2 Classification fixed as per KKS-Key for: - equipment units, apparatus - electrical and instrumentation equipment - measuring circuits and measuring conditioning - points of installation, coordinates - rooms, sections of structures AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 7/124 Project: Document No.: KKS - MASTERLIST STANDARD LH-DE011017-REV02 AN-N Counting numbers: - redundant zeros must be written - consecutive numbering or by groups - numbering starts anew if A1-2 changes AN-A Additional character, additional to the counting number, used for: - pilot valves - multiple measuring circuits - alternative identification for external limit switches - multiple supplies for electric loads 2.5 Breakdown Level 3 – COMPONENT KEY 0 G (A) (N) 1 F0 F1 F2 F3 FN FN 2 A1 A2 AN AN AN AN 3 B1 B2 BN BN (N) A A A A A N N A N N N (A) A N N B1-A Main group B2-A Subgroup B1-2 Classification fixed for components: - mechanical- or control components as per KKS-Key - electrical components as per KKS-Key for B2; B1 is a hyphen (-) - signal identification - identification of documents, drawing identification for electrical and control documents BN-N Counting numbers: - redundant zeros must be written - specified at signal numbers - specified at drawing identification 2.6 Notation of Breakdown Levels The details of the application of the code will be fixed by VA TECH HYDRO. Their use for a project must be observed exactly for each scope (in order to be electronically readable). Caution: Some CAD programs are not able to process blank characters or breakes. - without spacing (VA TECH HYDRO standard): 0 AN 1 N A A A N N 2 A A N N N A 3 A A A N N N N N - small spacing (special case): 0 AN 1 2 N A A A N N 3 A A A A N N - large spacing (special case): AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 8/124 Project: Document No.: KKS - MASTERLIST 0 AN 1 2 N A A A N STANDARD LH-DE011017-REV02 3 N A A N N N A A A N N - multiple-line notation (special case): 1 N A A A N N Line 2 2 A A N N N A Line 3 3 A A N N Line 1 2.7 0 AN Naming of the Breakdown Levels The breakdown levels have up to 3 different names and each will be according to the application: Breakdown level Process-related identification Point of installation identification Location identification Designation of data character Type of data character 0 Total plant Total plant Total plant G (A) (N) 1 2 Equipment key Installation space key Room key 3 Component key F0 Function key Installation unit key Structure key F1 F2 F3 FN FN A1 A2 AN AN AN A3 B1 B2 BN BN (N) A N A A A A N A N N N (A) A N N Process-related identification for: - Sections of plant and devices, process-related - Functions in electrical and control and instrumentation - Functions in mechanical and civil Point of installation identification for: - Devices at units (switchboard, panel) - Point at installation in rack (frame) Location identification for: - Structures (buildings, floors, levels) - Rooms, fire zones AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 9/124 KKS - MASTERLIST 2.8 Project: Document No.: STANDARD LH-DE011017-REV02 Prefixes The naming and breakdown levels are distinguished by means of: - Prefix symbols - Breakdown symbols Prefix symbols: = Plant, mode of process + Location - Electrical component : Connection The prefix symbols may be omitted if the information content remains unambiguous. Breakdown symbols: . Location Location-identification before breakdown level 2 (point of installation). 2.9 VATECH Standard design The spelling of the equipment designation takes place 3-lines according to standard, whereby the second line is filled out only for cabinet designations. Row1: = Process-related identification with breakdown levels 0-2 Row2: + Location with breakdown level 1, can be also with breakdown symbol Row3: Component key, process-related identification with breakdown level 3 The component keys are always counted up within a cubicle or a group of cubicles in contrast to the standard. The counting will not be restarted from 1 after a change of row 1. AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 10/124 Project: Document No.: KKS - MASTERLIST 3 STANDARD LH-DE011017-REV02 APPLICATION OF KKS 3.1 Process-Related Identification Breakdown level 0 Title of Breakdown level Total plant 1 2 Designation of data character G F0 F1 F2 F3 FN FN A1 A2 AN AN AN A3 B1 B2 BN BN Type of data character (A) (N) (N) A A A N N A A N N N (A) A A N N Function key 3 Equipment unit key Component key Electrical control and engineering Equipment unit, Apparatus, Instrumentation and control Equipment C&I-range, Manufacturing, Installation Total plant Part of plant Mechanical Engineering Device, Signal Equipment unit Apparatus Civil engineering Component Building This type of naming is used in most applications, because the plant components and electrical or control equipment will be addressed in a process- and system-related way. This identification classifies the equipment and devices according to their task in the total process. This block will use the prefix symbol "=". 3.2 Point of Installation-Identification Breakdown level Title of breakdown level Designation of data character Type of data character Electrical control and engineering Instrumentation and control equipment 0 Total plant + 1 Installation unit key 2 Installation space key G F0 F1 F2 F3 FN FN (A) (N) (N) A A A N N Total plant Switchboard Field Control desk . A1 A2 AN AN AN A3 A A N N N (A) Coordinate, Row, Floor Between breakdown level 1 and 2 the prefix symbol "." (period) will be written. The whole block will use the prefix symbol "+" (location). Combination with breakdown level 3 (component) is possible. AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 11/124 Project: Document No.: KKS - MASTERLIST 3.3 STANDARD LH-DE011017-REV02 Location Identification Breakdown level Title of breakdown level Designation of data character Type of data character 0 Total plant 1 Building code G (A) (N) Total plant + Civil engineering 2 Room code F0 F1 F2 F3 FN FN A1 A2 AN AN AN A3 (N) A A A N N A A N N N (A) Building Floor, flat Room Section This block will use the prefix symbol "+" (location). 3.4 Identification of Connections This identification is with the prefix symbol ":" (colon). There are 3 possibilities: 1. 2. 3. Identification after breakdown level 1: Connection to cubicles or switchgears without declaration of point of installation Identification after breakdown level 2: Connection to cubicles with declaration of point of installation Identification after breakdown level 3: Connection to component Breakdown level 0 (A) (N) Type of data character Electrical control and engineering (N) A A 2 A N N A A N 3 N N (A) A Equipment unit Instrumentation and control equipment Mechanical engineering 3.5 1 Total plant Plant, Cubicle, Field A N N Device Coordinate, Floor :N/A : Connect. : Connect. : Connect. Identification of Signals The process signals for electrical and control and instrumentation will be clearly defined in breakdown level 3 as "signal key". Using this identification, the exchange of signals between different parts of the plant will be facilitated and the connections within circuit (signal) diagrams will be unambiguously tagged. Breakdown level 0 Title of breakdown level Total plant 1 2 Designation of data character G F0 F1 F2 F3 FN FN A1 A2 AN AN AN A3 B1 B2 BN BN Type of data character (A) (N) (N) A A A N N A A N N N (A) A A N N Signalcode Total plant System key 3 Equipment unit key Part of plant AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 Component key Equipment unit C&I-range, Manufacturing, Signal C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 12/124 Project: Document No.: KKS - MASTERLIST STANDARD LH-DE011017-REV02 Identification of signals in breakdown level 3: Prefix in position B1 : X ....... Signal origins - according to origins of defined signal application Y ....... Signal application - according to application hierarchy defined Z ....... according to origins and defined like X, gated or calculated. Signal type in position B2 : These data characters are generally fixed by VA TECH HYDRO. Standard see chapter 5.1. Counting number in positions BN : Running number from 01 to 99. For various signal types the running number shall be fixed. Standard see chapter 5.1. 3.6 Identification of Cables Identification: according KKS and VGB guidelines The cable numbering is according to the combination of characters defined below. Breakdown level Title of breakdown level Designation of data character Type of data character Cable identification Example 0 Total plant G 1 Equipment identification F1 F2 F3 FN FN - BN BN BN BN (A) (N) Total plant A N N - N N N N 1 A A 2 Count number unit Plant area of the cable of associated aggregate C V A 0 1 Count number - 4 0 0 1 Cable of the first strapping connector of the first machine with an operating voltage < 60V The classifying part of the cable identification is defined by the both termination points at the switchboards, whereby the function identification which is leading in alphabetical order will prevail. From sub distributors to components, identification according to sub distribution identification is possible. The first position of the counting number of the resource indication serves the voltage level for the classification 0001 - 0999 1001 - 1999 2001 - 2999 3001 - 3999 4001 - 9999 Power cables >1kV Power cables <1kV Control cables, Controlling >60V Cables for measurement >60V Cables for control and measurement <60V Details of application 4001-9999 are subject to agreement between the parties to the project. AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 13/124 Project: Document No.: KKS - MASTERLIST STANDARD LH-DE011017-REV02 Example for cable number designation: PLC – Distribution Board 1CVA01 I 0BBA01-4001 0BJA02-4001 0BJA02-1001 1CVB01-4002 400V MCC 0BJA02 0BBA01-0002 C&I Junction box 1CVB01 6kV Switchgear 0BBA01 0BBA01-3001 Counter 1CFA02 0BBA01-0001 1CFA02-4001 1CVA01-4001 PLC – Distribution Board 1CVA01 P M Temperature sensor 1MKA20CP902 Drainage pump 0GMA10AP010 M M Cooling water pump 1PCB10AP010 Governor oil pump 1MEX10AP010 Identification: according KKS and VGB-guidelines Assignment of cable identification is using breakdown level 2 (equipment key) AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 14/124 Project: Document No.: KKS - MASTERLIST 3.7 STANDARD LH-DE011017-REV02 Identification of Documents Documents that will be supplied and are necessary for operation of the plant are: - general technical documents - electrical and control and instrumentation documents - mechanical documents - civil documents For these documents, a separate identification will be provided. This identification of documents serves to address a document and to define its location in the whole documentation - regardless of the drawing numbers of the different subcontractors. The documentation identification consists of 3 parts: - Equipment identification: - Type of document key: - Counting number 3.8 KKS-breakdown level 0-2 classified by a combination of characters Example of KKS application The previous examples of KKS use give a general overview of the structure and main uses of KKS. Part A General KKS application commentaries Part B Engineering discipline-specific application commentaries B1 B2 B3 B4 Mechanical engineering Civil engineering Electrical engineering and control and instrumentation Coding of process control and instrumentation D1 Explanations for Hydro Power Plants see chapter 6 AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 15/124 KKS - MASTERLIST Project: Document No.: STANDARD LH-DE011017-REV02 Example 3.8/1 Process related identification of power current and control and instrumentation and Distribution A Grid system transmission and B Power auxiliary power supply and C Instrumentation control equipment and D Instrumentation control equipment fuel supply E Conventional and residues disposal of nuclear F Handling equipment G Water supply and disposal heat H Conventional generation J Nuclear heat generation K Reactor auxiliary system water-, gas-, L Steam-, cycles M Main machine sets energy supply for N Process external users P Cooling water supply Q Auxiliary systems generation and R Gas treatment S Ancillary systems T Blocked U Structures V Blocked W Renewable energy plants X Heavy machinery Y Blocked and office Z Workshop equipment AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 16/124 KKS - MASTERLIST Project: Document No.: STANDARD LH-DE011017-REV02 Example 3.8/2 Process related identification of control and instrumentation and Distribution A Grid system transmission and B Power auxiliary power supply and C Instrumentation control equipment and D Instrumentation control equipment fuel supply E Conventional and residues disposal of nuclear F Handling equipment G Water supply and disposal heat H Conventional generation J Nuclear heat generation K Reactor auxiliary system water-, gas-, L Steam-, cycles M Main machine sets energy supply for N Process external users P Cooling water supply Q Auxiliary systems generation and R Gas treatment S Ancillary systems T Blocked U Structures V Blocked W Renewable energy plants X Heavy machinery Y Blocked and office Z Workshop equipment AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 17/124 KKS - MASTERLIST Project: Document No.: STANDARD LH-DE011017-REV02 Example 3.8/3 Process related identification of control and instrumentation and Distribution A Grid system transmission and B Power auxiliary power supply and C Instrumentation control equipment and D Instrumentation control equipment fuel supply E Conventional and residues disposal of nuclear F Handling equipment G Water supply and disposal heat H Conventional generation J Nuclear heat generation K Reactor auxiliary system water-, gas-, L Steam-, cycles M Main machine sets energy supply for N Process external users P Cooling water supply Q Auxiliary systems generation and R Gas treatment S Ancillary systems T Blocked U Structures V Blocked W Renewable energy plants X Heavy machinery Y Blocked and office Z Workshop equipment AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 18/124 KKS - MASTERLIST Project: Document No.: STANDARD LH-DE011017-REV02 Example 3.8/4 Process related identification of control and instrumentation and Distribution A Grid system transmission and B Power auxiliary power supply and C Instrumentation control equipment and D Instrumentation control equipment fuel supply E Conventional and residues disposal of nuclear F Handling equipment G Water supply and disposal heat H Conventional generation J Nuclear heat generation K Reactor auxiliary system water-, gas-, L Steam-, cycles M Main machine sets energy supply for N Process external users P Cooling water supply Q Auxiliary systems generation and R Gas treatment S Ancillary systems T Blocked U Structures V Blocked W Renewable energy plants X Heavy machinery Y Blocked and office Z Workshop equipment AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 19/124 KKS - MASTERLIST Project: Document No.: STANDARD LH-DE011017-REV02 Example 3.8/5 Identification of rooms and Distribution A Grid system transmission and B Power auxiliary power supply and C Instrumentation control equipment and D Instrumentation control equipment fuel supply E Conventional and residues disposal of nuclear F Handling equipment G Water supply and disposal heat H Conventional generation J Nuclear heat generation K Reactor auxiliary system water-, gas-, L Steam-, cycles M Main machine sets energy supply for N Process external users P Cooling water supply Q Auxiliary systems generation and R Gas treatment S Ancillary systems T Blocked U Structures V Blocked W Renewable energy plants X Heavy machinery Y Blocked and office Z Workshop equipment AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 20/124 Project: Document No.: KKS - MASTERLIST STANDARD LH-DE011017-REV02 Example 3.8/6 Identification of piping systems Counting of ropes and sections with 10-steps in FN. 31 32 21 10 22 41 42 30 30 43 50 23 44 VA TECH HYDRO – Standard: Breakdown level 0 is assigned per unit. It is the more flexible system, and our guideline. AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 21/124 KKS - MASTERLIST Project: Document No.: STANDARD LH-DE011017-REV02 This example represents an exception, because breakdown level 0 is assigned plant specific numbering (for example an existing plant) Attention: be careful with identification numbers, don’t forget to allow for spares! AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 22/124 Project: Document No.: KKS - MASTERLIST STANDARD LH-DE011017-REV02 Example 3.8/7 Identification of control loops Single control loop Pressure control PAB01DP001 PAB01 CP001 PAB01 AA001 Control loop with combined control values PAB01 CP001 PCA10 CP001 PAB General cooling water PCA Secondary cooling water Pressure control PYA01DP001 For equipment comprising of more than one system, defined in F2 and F3, then „Y“ will be used in the relevant character designation. Example: PAB PAC PAD PA.. PAY AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 PY.. PC.. C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 23/124 Project: Document No.: KKS - MASTERLIST STANDARD LH-DE011017-REV02 Example 3.8/8 Identification of measuring circuits Example: Flow measurement MEX10CF001 Identification in breakdown level 3 Power house UME17GZ001 Junction box UME17GF001 Valve block MEX10CF001 KA01 Measuring transducer MEX10CF001-B01 cable DUME17-4001 Trunk cable drain lines cote +17m Main steam flow measurement in boiler house on level +17m AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 24/124 Project: Document No.: KKS - MASTERLIST STANDARD LH-DE011017-REV02 Example: Temperature measurement MEX10CT001 Identification in breakdown level 3 Governor oil temperature measurement MEX10CT001 pipe MEX10BR001 protective well MEX10CT001 QT01 thermocouple MEX10CT001 -B01 head mounted T/I-X´ter MEX10CT001 -U01 cable MEX10-4001 ® ideal definition for instrument list AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 25/124 Project: Document No.: KKS - MASTERLIST STANDARD LH-DE011017-REV02 Example 3.8/9 Identification with signal processing Example: Identification of specific equipment Control equipment: oil vapour exhaust = MEX11AN001 Equipment specific signal processing Oil vapour exhaust 1 Automatic Control equipment & ≥1 [ o o o Interlock Control room Protect. MEX11AN001 M If control and instrumentation equipment applies only for one unit (measuring, controlling, safety interlocking), the processed signal will be designated with the identification of the unit. AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 26/124 KKS - MASTERLIST Project: Document No.: STANDARD LH-DE011017-REV02 Example 3.8/10 Identification at grid and auxiliary service supply systems Example: Water power plant, conceptual flow diagram; Identification in breakdown level 1 AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 27/124 Project: Document No.: KKS - MASTERLIST 3.9 STANDARD LH-DE011017-REV02 Registration in graphical symbols Representation of C&I tasks according to DIN 19227 Output and operation-location: Local Central Control Room Local Control Panel MSR KKS MSR KKS MSR KKS MSR ..... C&I Function Code letter KKS ...... KKS-number breakdown level 0, 1 and 2 MSR-code letter according to DIN 19227 and ISO 3511: POSITION 1 Character Feedback signal D E F G H K L M P Q R S T U V W Density Electrical value Flow Position, Spacing, Length Hand operation Time Level Humidity Pressure Quality (Analysis) Radiation Velocity, Frequency Temperature Combined Value Viscosity Weight, Mass POSITION 2 Additional character to 1 POSITION 3 Supplementary character (processing) D F Q A C E I O R S T V Y Z H L / Difference Ratio Sum, Quantity Alarm, Limit value Closed loop control Sample, sensor function Analog indicator Indication, binary, Yes/No Recording Interlock, Open loop control Transmitter function Positioner function Computing function Protection, Emergency stop High/Upper limit (or +) Lower limit (or -) Middle value The characters in position 3 must be written in the following order: E-O-I-R-C-S-Y-Z-A-H-L AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 28/124 Project: Document No.: KKS - MASTERLIST STANDARD LH-DE011017-REV02 Registration in graphical symbols Example: TIAH 1MKA10CT001 Remote sensing, temp. measurement (Signal 4 – 20 mA to CCR; alarm derived internal) PI 1MKV10CP501 Local measurement Pressure gauge QR 1MKV20CQ001 Remote sensing, analysis (Signal 4 – 20 mA to CCR, recorded) PSAL 1MMH10CP301 Pressure switch (Binary signal to CCR) PI 1MMH10CP301 Pressure gauge with contact (Local indication; binary signal to CCR) PSAL 1MMH10CP301 LI 1MKD20CL301 Local level indication with contact (Local indication; signal to CCR) LSAH 1MKD20CL301 Remote sensing, pressure transmitter (Signal 4 – 20 mA to CCR for control and recording) PICR 1MKY10CP001 Identification of instruments, tanks, pumps, etc. in flowcharts: ............... ............... ..... KKS breakdown level 0 and 1 ..... KKS breakdown level 2 1MEX20 AA001 1MEX20 AP001 1MEX20 BB001 Governor oilControl valve Governor oilpump Governor oiltank Example: AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 29/124 Project: Document No.: KKS - MASTERLIST STANDARD LH-DE011017-REV02 3.10 Loops with multiple probes at one location Multiple loops with one measurement location (transmitter) will be distinguished from each other in the aggregate breakdown level by means of the supplementary character A3. This applies to temperature measurements with dual thermocouples, flow measurements with multiple probes as well as double secondary current transformers or voltage transformers connected to loops. Example: temperature measurement with dual thermocouples Loop A MEX10CT001A MEX10BR001 MEX10CT001 Loop B MEX10CT001B Should a dual thermometer be used as a sensor, whereby only one connection is used (second connection as spare), then only one loop number will be assigned and the supplementary character A3 will not be used. Example: loop with multiple probes MEX10CF001A MEX10BR001 MEX10CF001 MEX10CF001B MEX10CF001C AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 30/124 Project: Document No.: KKS - MASTERLIST STANDARD LH-DE011017-REV02 3.11 Gating of loops The general rule for gating signals is that the code of the signal to be processed, and thus the physical measurement, will be retained as far as possible. Gating of measurements of the same type (i.e. both pressure, multiple temperatures, etc.) will be distinguished by a certain character, e.g. “9”, in the position AN and keep the designation of the physical measurement in the position A2 . Example: Calculation of a temperature difference CT011 CT012 Temperature difference CT901 When signals are used to limit or suppress a measurement value, the output signal of the signal processing keeps the character designation of the original measurement and only the first character of the component key will be changed from *X* to *Z*. Example: Suppressed alarm ..... CP303 XG01 Pressure after pump < min ..... AP001XB01 Pump is ON 10” 0 & ..... CP303 ZG01 Alarm: Pressure after pump < min AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 31/124 Project: Document No.: KKS - MASTERLIST STANDARD LH-DE011017-REV02 3.12 Identification of Loops 3.12.1 Identification of direct loops Direct loops will be designated with *C* in the data character A1 in breakdown level 2. The position A2 corresponds to the measured physical value (e.g. pressure, temperature) in accordance with DIN 19227. In breakdown level 1, the loops are assigned the identification of the system of which the loop is a part. In other words, the loop will be named after the system where its measurement probe is located. Example 3.12.1/1 System 1 System 2 CT002 CT001 M CF001 CP001 CT001 Medium-direction of flow Example 3.12.1/2 Medium-direction of flow MEX10 MEX10CP001 AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 MEX10 MEX10CP002 C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 32/124 Project: Document No.: KKS - MASTERLIST STANDARD LH-DE011017-REV02 The measured physical value, and not the measuring principle, determines the data character of position A2. Loops for the same physical value within a given system (FN) should be assigned increasing numbers according to material and energy flow. Should new loops be added or loops deleted, the other existing loops should not be re-numbered. Seeing that loops normally have a specifically assigned designation in the equipment unit key (breakdown level 2), measurements on a given piece of equipment will not be named after the equipment but after the loop. These include level measurements on tanks, analog position measurements of valves, frequency measurements, motor core temperatures, etc. Example 3.12.1/3 CL013 CT008 CL012 M CG003 M CS008 AA003 AP003 In this example there are loops for the individual components of the system. The level measurement on the tank will not be named after the tank, but will be assigned an individual loop designation. Similarly, the frequency and temperature measurements on the pump motor are individual loops. The same applies to the valve analog position measurement. By means of careful number assignment for position AN, it is possible to retain the relationship to the equipment (e.g. valve AA003 with positioning loop CG003). AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 33/124 Project: Document No.: KKS - MASTERLIST STANDARD LH-DE011017-REV02 3.12.2 Identification of indirect loops As opposed to direct loops, indirect loops are not used for the direct measurement of a physical value, but used, in combination with other loops, for the calculating and compensation of measurement values. The signal is not generated directly from a process measurement using probes, but by mathematical calculation. The resulting new signals represent new or different information. In order to clearly differentiate these signals and their associated equipment from the related direct process signals, the data character in position A1 will be assigned *F* (indirect loop) instead of *C*. The data character 2 will be assigned a letter according to its physical value (DIN 19227), as for the direct loops. Example 3.12.2/1: Pressure and temperature compensated flow measurement using the original measured value CP011 CF009 CT015 Compensation CF009 FF009 Example 3.12.2/2: Temperature compensated flow measurement using multiple measurements in a 2 out of 3 configuration CT001 CT002 2 of 3 CT901 CT003 Compensation FF... CF001 CF002 2 of 3 CF003 AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 CF901 C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 34/124 Project: Document No.: KKS - MASTERLIST STANDARD LH-DE011017-REV02 Measured value processing of signals of different physical values will be assigned *U* (gating of differing physical values) to data character A2. Example 3.12.2/3: Calculation of a value from 2 different physical values e.g. enthalpy. CP001 Y= f(T&P) FU001 CT001 Example 3.12.2/4: Calculation of a value from changing physical values e.g. limiting curve Y= f(P) CP001 FP001 CP001 Example 3.12.2/5: Calculation of a value from 2 different physical values, whereby one is a calculated value and the other a direct measurement. e.g. flow with mass compensation PD001 CF001 Y= f(б x Q) AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 FF001 C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 35/124 Project: Document No.: KKS - MASTERLIST STANDARD LH-DE011017-REV02 Example 3.12.2/6: Calculation of 2 output signals using a maximum selection from 2 groups of 3 measured values, which are obtained from a selection gate e.g. dual line HP-steam system ... 10CP001 ... 10CP002 ... 10CP003 ... 20CP001 ... 20CP002 ... 20CP003 2 out of 3 2 out of 3 2 out of 3 2 out of 3 AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 ... 10CP901A MAX ... 00CP901A MAX ... 00CP901B ... 20CP901A ... 10CP901B ... 20CP901B C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 36/124 Project: Document No.: KKS - MASTERLIST STANDARD LH-DE011017-REV02 Example 3.12.2/7: Calculation of an output signal using a selection, where a sum of signals takes place beforehand. Each system contains a flow measurement with 3 transmitters at one measurement point, with separate compensations, for the protection criteria for the HP-steam flow of a dual line steam system. MEX 10CT001 MEX10CF001A Compen- MEX10FF001A sation ∑ MEX00FF001A ∑ MEX00FF001B MEX10CT002 MEX10CF001B Compen- MEX10FF001B sation MEX 10CT003 MEX10CF001C Compen- MEX10FF001C sation MEX20CT001 MEX20CF001A 2 MEX00FF901 out of 3 Compen- MEX20FF001A sation MEX20CT001 MEX20CF001B Compen- MEX20FF001B sation MEX20CT001 MEX20CF001C Compen- MEX20FF001C sation AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 ∑ MEX00FF001C C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 37/124 Project: Document No.: KKS - MASTERLIST 4 STANDARD LH-DE011017-REV02 EXTENDED KKS – KEY (STANDARD) Breakdown Level 2 Example: Control element with limit switch for intermediate position 1. Identification for regulating actuator signals: in breakdown level 2 (equipment unit key), numbering according to list, signal number (not indicated on P&I-diagram) 2. Identification for external signals: a) in breakdown level 2, numbering as for the valve, with supplementary data char. (A3): A open (100%) B closed (0%) C 1. Intermediate position (e.g. 30%) D 2. Intermediate position (etc.) (The advantage here is, that the external limit switches can be easier referred to the valve, and if there are more valves in the same system, no problems with numbering will occur. b) or with individual KKS-identification, as below mentioned (standard solution): 1MEA10AA101 -M01 “Matic”-type actuator, “inching controlled” M~ Feedback signals & 1st actuator control commands (actuator internal signals) Limit switch 100% Limit switch 0% Torque switch open Torque switch close Remote/Local Common fault Command “open” Command “close” 1MEA10AA101 XB01 1MEA10AA101 XB02 1MEA10AA101 XB27 1MEA10AA101 XB28 1MEA10AA101 XB22/23 1MEA10AA101 XB07 1MEA10AA101 YB01 1MEA10AA101 YB02 2nd external signal (ext. field instruments) G analog 0¸100% 1MEA10CG001 XQ01 G Limit switch 100% G Limit switch 30% G Limit switch 0% 1MEA10CG301 XG01 (or 1MEA10CG101A) 1MEA10CG303 XG03 (or 1MEA10CG101C) 1MEA10CG302 XG02 (or 1MEA10CG101B) 1MEA10AA101 AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 38/124 Project: Document No.: KKS - MASTERLIST STANDARD LH-DE011017-REV02 BREAKDOWN LEVEL 2 [AN/AN/AN] Loop Numbering Assignment for Electrical Equipment: Example: Generator leads BAA10CE211A – voltage L1 – core 1 BAA10CE212A – voltage L2 – core 1 BAA10CE213A – voltage L3 – core 1 BAA10CE214B – voltage L1/L2 – core 2 BAA10CE215B – voltage L2/L3 – core 2 BAA10CE216B – voltage L3/L1 – core 2 2 A/B BAA10CE111A – current L1 – core 1 BAA10CE113A – current L3 – core 1 BAA10CE111B – current L1 – core 2 BAA10CE112B – current L2 – core 2 BAA10CE113B – current L3 – core 2 G 2 A/B BAB10CE111A – current L1 – core 1 BAB10CE112A – current L2 – core 1 BAB10CE113A – current L3 – core 1 BAB10CE111B – current L1 – core 2 BAB10CE112B – current L2 – core 2 BAB10CE113B – current L3 – core 2 BAB10CE210 – voltage star point AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 39/124 Project: Document No.: KKS - MASTERLIST 5 STANDARD LH-DE011017-REV02 IDENTIFICATION OF C&I COMPONENTS 5.1 Signal identification 5.1.1 General Signal Identification The component key is used to differentiate the various signals that are part of a given system or piece of equipment. Breakdown level Title of breakdown level Designation of data characters Type of data characters 0 Total Plant 1 Function 2 Equipment 3 Component B1 B2 BN A A NN Prefix X, Y or Z Signal range Signal-No. The letters X, Y and Z have the following meaning: X Y Z Signal origins Application signals Gated signals The signal ranges and applications are designated in the 2nd alphabetical data character. The individual signal types and applications are designated in the following 2 numerical data characters. Seeing that the required guidelines for the signal designations of the equipment and the application data characters are also dependent on the related documentation technology, the following examples do not show signal designations that are valid generally for all projects, but can be used basically or shall be used if there is no other standard available. The manufacturer-specific guidelines must be referred to, and implemented for each project individually. The signal designation of the individual derived process values and C&I signals are fixed by the VA TECH HYDRO Standard. Exceptions allowed only by permission of VA TECH HYDRO. The following examples illustrate the VA TECH HYDRO Standard guidelines. AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 40/124 KKS - MASTERLIST Project: Document No.: STANDARD LH-DE011017-REV02 5.1.2 Designation letter for the signal range/application (Standard / Overview) Signal B1+B2 XA/YA XB/YB XC/YC XD XE XF XG/YG XH XJ/YJ XK XL/YL XM XN XP/YP XQ/YQ XR/YR XS XT XU XV/ZV XW _X _Y _Z Definition Functional group control and/or subloop control Open-loop control for drive & breaker interfaces Closed loop control, controller feedback (no field) signals Free for use by VA TECH HYDRO Free for use by VA TECH HYDRO Free for use by VA TECH HYDRO Binary process signals (incl. conditioning if necessary) Binary limit signals derived from analog process signals Black-Box signals or signals from non-standard areas Equipment unit & component protection Control room & operator desk signals (e.g. push-button) Static individual & group process alarm signals Criteria computer system signals (please do not use) Process computer system signals (joint control) Analog process signals (XQ from field, YQ to field) Closed loop control, controller signals (no field signals) Sequence steps (no field signals) Special signals from turbine control Dynamic individual & group alarm signals Gated signals for protective logic & alarm logic Hardwired alarm annunciation system (please do not use) Blocked Blocked Free for use by VA TECH HYDRO binary analog binary binary binary X Y Z XA YA XB YB XC YC binary binary anlg/bin binary binary binary anlg/bin anlg/bin analog analog binary binary binary binary binary XG YG XH XJ YJ XK XL YL XM XN XP YP XQ YQ XR YR XS XT YT XU XV YV ZV XW YW binary XZ YZ ZZ Blocked = for future uniform guidelines Caution: Manufacturer hardware-related deviations are permitted AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 41/124 Project: Document No.: KKS - MASTERLIST 5.2 STANDARD LH-DE011017-REV02 Binary signals (contacts) and limit values from signal conditioning 5.2.1 Designation letter (signal range) G H = = contact limit value (binary process signal incl. conditioning for contacts) (derived from analog measurement signals) 5.2.2 Signal numbers for binary process signals (contacts) Most of the binary process signals (contacts) are signals from field instruments as follows: -limit switches -pressure switches -temperature switches -level switches with only one contact. Each instrument will have an individual KKS-Number. The contact/signal from each field instrument will get therefore the same signal code: XG01 for “normally open”-contact, and XG51 for “normally close”-contact. For field instruments with tandem (or triple) switches with same limit value, we recommend: XG01/51 for the first switch XG11/61 for the second switch XG21/71 for the third switch For field instruments with two (or more) switches with individual limit value, we recommend “odd”-numbers for “high”-limit values, “even”-numbers for “low”-limit values: XG01/51 for the “high”-limit value XG02/52 for the “low”-limit value XG03/53 for the “high/high”-limit value XG04/54 for the “low/low”-limit value XG05/55 for the “high/high/high”-limit value XG06/56 for the “low/low/low”-limit value 5.2.3 Signal numbers for limit values derived from analog process signals The analog process signal will have normally the signal code XQ01 for standard transmitters. The derived binary limit values will be produced internal in the DCS/PLC, standard as follows: “odd”-numbers for “high”-limit values, “even”-numbers for “low”-limit values: XH01/51 for the “high”-limit value XH02/52 for the “low”-limit value XH03/53 for the “high/high”-limit value XH04/54 for the “low/low”-limit value XH05/55 for the “high/high/high”-limit value XH06/56 for the “low/low/low”-limit value AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 42/124 Project: Document No.: KKS - MASTERLIST STANDARD LH-DE011017-REV02 Example 5.1.1/1: Signal designation for a ultrasonic level sensor with signal converter LA2H LSH normal level NO/NC contacts DCS input card LSL LSA2L XG03 >10m >high/high XG53 <10m <high/high XG01 >8m >high XG51 <8m <high signal code limit value XG02 <3m <low XG52 >3m >low XG04 <1m <low/low XG54 >1m >low/low Level Example 5.1.1/2: Level signals derived from an analog level transmitter signal: XH03 >10m XH53 <10m XH01 >8m XH51 <8m L >high/high <high/high >high <high XQ01 I XH02 <3m XH52 >3m XH04 <1m XH54 >1m AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 <low >low <low/low >low/low C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 43/124 KKS - MASTERLIST Project: Document No.: STANDARD LH-DE011017-REV02 6 EXPLANATIONS FOR HYDRO POWER PLANTS FROM VGB-D1 In this section in the special hydro-electric power plants are processed. It is dealt with the different machine types and their demarcations, as well as on their auxiliaries. These suggestions can deviate however from the VATECH standard slightly. 6.1 Identification of breakdown level 1 6.1.1 Identification mechanical Identification of machine sets (M _ _ ) · Water turbine plants (ME_) Kaplan turbine (ME_) o MEA10 MEA20 MEA30 MEA40 MEA50 MED10 MED20 MKA10 Spiral case, draft tube including stay vanes Wicket gate including all operating mechanisms Runner including all operating mechanisms Shaft Turbine brake system Turbine thrust bearing or combined thrust guide bearing Turbine guide bearing Generator If there is a common oil supply system for generator and turbine bearings must it with MV_ be designated. The shaft can be assigned to the turbine or the generator, whereby the coupling makes a demarcation possible. In addition, it is to be taken on the structural condition consideration. AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 44/124 KKS - MASTERLIST Project: Document No.: STANDARD LH-DE011017-REV02 Identification of non-electric control and protection equipment (MEX) A separate scheme for this system is established in the number sequence since a Kaplan turbine with runner and wicket gate requires many identification details. MEX10 MEX20 MEX30 MEX50 MEX60 MEX70 Pressure oil supply system for runner and wicket gate control Wicket gate control Runner blade control Brake control Pressure oil generation and control of upper water stop valve Safety equipment for the turbine and emergency shutdown equipment The connecting flanges to the servomotor constitute the interfaces between the control and governor system MEX and the turbine MEA or the upper water stop valve MEB. Identification of electric control and protection equipment (MEY) Also is here the identification in the number sequence. MEY10 MEY20 MEY40 MEY70 Turbine governor Automatic start and stop sequence Separate speed detection and evaluation Turbine protection (such as emergency shutdown sequence) Identification as “C _ _” can also be selected where an overall control task is concerned which contains a number of individual tasks. The electric connection to the servo valve constitutes the interface between the control and protection equipment MEY and the turbine MEA or its hydraulic governor system MEX. The identification of the coil is therefore MEX. AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 45/124 KKS - MASTERLIST o Francis turbine Project: Document No.: STANDARD LH-DE011017-REV02 (ME_) Because the constructional structure differs to the Kaplan turbine strongly, its own number structuring is specified. MEA10 MEA20 MEA30 MEA40 MEA50 MEB10 MEB20 MED10 MED20 MKA40 Turbine inlet and outlet, spiral case including drainage system (Where a distinction is to be made between the inlet end and outlet end, MEA11 is used for the inlet and MEA15 for the draft tube selection). Wicket gate Runner Turbine shaft Turbine brake system Main inlet valve in turbine inlet including bypass Shutoff valve in turbine outlet Turbine thrust bearing or combined thrust guide bearing Turbine guide bearing Generator shaft Identification of non-electric control and protection equipment (MEX) A identification scheme for the control and governor equipment for Francis turbines is analogous to that of Kaplan turbines. MEX10 MEX20 MEX50 MEX60 MEX70 Pressure oil supply system for wicket gate control Wicket gate control Brake control Pressure oil generation and control of upper water stop valve Safety equipment for the turbine and emergency shutdown equipment The connecting flanges to the servomotor constitute the interfaces between the control and governor system MEX and the turbine MEA or the upper water stop valve MEB. AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 46/124 Project: Document No.: KKS - MASTERLIST o Pelton turbine STANDARD LH-DE011017-REV02 (ME_) Also for the Pelton turbine its own number structuring is specified. MEA10 MEA20 MEA30 MEA40 MEA50 MEB10 MED10 Turbine inlet manifold and housing (Where a distinction is to be made between the inlet end and outlet end, MEA11 is used for the inlet and MEA15 for the outlet). Injectors and deflectors Runner Turbine shaft Turbine brake system Main inlet valve (spherical valve) including bypass Turbine thrust bearing Identification of non-electric control and protection equipment (MEX) A identification scheme for the control and governor equipment for Pelton turbines is analogous to that of Kaplan turbines. MEX10 MEX20 MEX30 MEX50 MEX60 MEX70 Pressure oil supply system for injector and deflector control Injector control Deflector control Brake control Pressure oil generation and control of upper water stop valve Safety equipment for the turbine and emergency shutdown equipment The connecting flanges to the servomotor constitute the interfaces between the control and governor system MEX and the turbine MEA or the upper water stop valve MEB. AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 47/124 Project: Document No.: KKS - MASTERLIST · Pump turbine plants STANDARD LH-DE011017-REV02 (MF_) In pump turbine plants one runner combines the functions of pump and turbine. MFA10 MFA20 MFA30 MFA40 MFA50 MFB10 MFD10 MFD20 MFM10 Turbine inlet and outlet, spiral case including drainage system (Where a distinction is to be made between the inlet end and outlet end, MFA11 is used for the inlet and MFA15 for the draft tube selection). Wicket gate Runner Turbine shaft Turbine brake system Main inlet valve (spherical valve) inlet including bypass Turbine thrust bearing or combined thrust guide bearing Turbine guide bearing Starting device (starting turbine or electric starting device) Identification of non-electric control and protection equipment (MFX) A identification scheme for the control and governor equipment for Pump turbines is analogous to that of Francis turbines. MFX10 Pressure oil supply system for wicket gate control MFX20 Wicket gate control MFX50 Brake control MFX60 Pressure oil generation and control of upper water stop valve MFX70 Safety equipment for the turbine and emergency shutdown equipment The connecting flanges to the servomotor constitute the interfaces between the control and governor system MFX and the turbine MFA or the upper water stop valve MFB. Identification of electric control and protection equipment (MFY) Also is here the identification in the number sequence. MFY10 Pump turbine governor MFY20 Automatic start and stop sequence MFY40 Speed detection mounted on the shaft MFY70 Turbine protection (such as emergency shutdown sequence) Identification as “C _ _” can also be selected where an overall control task is concerned which contains a number of individual tasks. The electric connection to the servo valve constitutes the interface between the control and protection equipment MFY and the turbine MFA or its hydraulic governor system MFX. The identification of the coil is therefore MFX. AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 48/124 Project: Document No.: KKS - MASTERLIST · Storage pump plant STANDARD LH-DE011017-REV02 (MG_) Storage pumps in storage pump plants serve to pump the water from the lower reservoir of the plant back to the upper reservoir or to the water impounding system. Pumping stations and admixture equipment are classified as “LNF” MGA10 MGA20 MGA30 MGA40 MGA50 MGB10 MGB20 MGD10 MGD20 MGK10 MGM10 Pump inlet, housing and pump outlet (Where a distinction is to be made between the inlet end and outlet end, MGA11 is used for the inlet and MGA15 for the draft tube selection). Wicket gate Runner Shaft Mechanical brake system for the pump Main inlet valve in upperwater system Main inlet valve in underwater system (draft tube valve) Thrust bearing or combined thrust guide bearing Guide bearing Hydraulic converter Starting device (starting turbine or electric starting device) The numbering of MGK and MGM shall have the same systematic of identification as for the associated main machine set. AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 49/124 KKS - MASTERLIST Project: Document No.: STANDARD LH-DE011017-REV02 Identification of non-electric control and protection equipment (MGX) A identification scheme for the control and governor equipment for Storage pump is analogous to that of Francis turbines. MGX10 MGX20 MGX50 MGX60 MGX70 MGX80 Pressure oil supply system for wicket gate control Wicket gate control Brake control Pressure oil generation and control of upper water stop valve and draft tube valve Safety equipment for the turbine and emergency shutdown equipment Converter control The connecting flanges to the servomotor constitute the interfaces between the control system MGX and the pump MGA or the upper water stop valve MGB. Identification of electric control and protection equipment (MGY) Also is here the identification in the number sequence. MGY10 MGY20 MGY40 MGY70 Storage pump control Automatic start and stop sequence Speed detection mounted on the shaft Storage pump protection (such as emergency shutdown sequence) Identification as “C _ _” can also be selected where an overall control task is concerned which contains a number of individual tasks. The electric connection to the servo valve constitutes the interface between the control and protection equipment MGY and the pump MGA or its hydraulic control system MGX. The identification of the coil is therefore MFX. AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 50/124 Project: Document No.: KKS - MASTERLIST · Generator system STANDARD LH-DE011017-REV02 (MK_) The generator is identified as a functionally independent entity. The interface between generator and turbine cannot be established unequivocally since it is in turn governed by the physical configuration of the machine set. The VATECH standard deviates here from the VGB Guideline. The reason is a standardisation of many years in the generator division. The VGB Guideline identify as follows: MKA10 Generator frame with stator MKA20 Generator rotor MKA30 All integral air cooling equipment MKA40 Shaft MKA50 Mechanical brake system MKA60 Brush dust removal system MKB10 MKC10 MKD10 MKD20 MKF10 MKG10 Electrical brake system Excitation system Generator thrust bearing or combined thrust guide bearing Generator guide bearing Generator cooling system – water Generator cooling system – gas The VATECH standard identify as follows: MKA10 Generator rotor MKA20 Stator winding MKA30 Stator core MKA40 Shaft MKA60 Brush dust removal system MKA80 Stator Cooling MKA81 Stator Hot Air MKA82 Stator Cold Air MKA90 Brake / Lifting system MKA91 Braking MKA92 Lifting MKC10 Excitation system MKD20 Upper bearing MKD30 Lower bearing MKF10 Generator cooling system - Water MKF20 Cooling water Upper Bearing MKF30 Cooling water Lower Bearing · Motor generator system (ML_) For identification of motor generators the same identification scheme is used as for the generator, only the letter “_K_” is changed to “_L_”. AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 51/124 Project: Document No.: KKS - MASTERLIST STANDARD LH-DE011017-REV02 Identification of hydraulic main systems (L _ _ ) · Water impounding works (LN_) The following equipment and systems that serve to collect and store water are part of the water impound works. These cover: Water intake, small water inflows, ponds, reservoirs, associated trash/fish barriers, pump systems, dams with spillway and drainage systems, weir systems including auxiliary systems and fluid supply systems for control and protection equipment. · Intake and headwater system (LP_) All equipment and systems for shutting off and conducting the headwater from including the intake rake to excluding the main inlet valve of the main machine set. These cover: Trash rack and rack cleaning system, gates, shut off valves and butterfly valves, piping and penstock system systems including auxiliary systems and fluid supply systems for control and protection equipment. · Tail race and tail water system (LQ_) All equipment and systems for shutting off and conducting the tailwater from including the tube valves of the machine set or including the outlet from the turbine to excluding the underwater impound works or subsequent barrage. These cover: Sluice gate flaps, cleaning systems for pump operation, culvert systems and surge tanks including auxiliary systems and fluid supply systems for control and protection equipment. · Combined systems (LS_) In addition belongs to the Penstock drain system and the machine drain system. Remark: The leakage water collection and drainage system is identified as “GM_” LNA LNC LPA LPB LPC LQA LQC MEA MKA SHA SHB SHC SHE SHF Headrace system Dam, weir system Rake and rake cleaning system Isolating equipment Piping and penstock system Tailwater piping system Isolating equipment Water turbine Generator plant Upstream canal Lock chamber Upper lock chamber gate Lower lock chamber gate Downstream canal AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 52/124 Project: Document No.: KKS - MASTERLIST STANDARD LH-DE011017-REV02 Identification of cooling water systems (P _ _ ) · Main cooling system (PA_) For the entire cooling water system of a hydroelectric power plant the designation scheme is used according the type of cooling water supply. The individual systems are differentiated again in the number sequence, whereby a partitioning in the last character of the number sequence can be done. PAA10 PAB00 PAB10 PAB20 PAB30 PAB40 PAC10 Extraction, supply and cleaning Piping system to excl. branch off other systems Individual system transformer Individual system generator Individual system turbine/pump-turbine Individual system storage pump Pump system The limit is the inlet / outlet of the cooler of the respective cooling system. Thus the cooler is assigned to the transformer for example. AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 53/124 KKS - MASTERLIST Project: Document No.: STANDARD LH-DE011017-REV02 Identification of auxiliary systems (Q _ _ ) The air production divides into the group of compressed air and control air. Compressed air serves the out blowing of the turbine and draft tube for the condenser operation and control air for control of various components. · · Compressed Air Control Air (QE_) (QF_) Where only one air compressor system is used for more than one task in a power plant, it is identified as “QE_”. Where a common compressor generates the control air and stationary compressed air (SC_) it is identified as “QF_” The compressed air system encompasses the connection to the user or his fitting. The compressors for air replenishment of air-oil pressure tanks in governor oil systems are identified as “MEX”, “MFX” and “MGX” according to the originator principle. QEA10 QEB00 QEB10 QEB20 QFA10 QFA00 QFB10 QFB20 SCA10 SCB00 SCB10 SCB20 MEG10 MEL10 MFG10 MFL10 MGG10 MGL10 Central water depression (blow down) air generation Central water depression (blow down) air distribution Individual system 1 Individual system 2 Central air generation Central air distribution Individual system 1 Individual system 2 Stationary compressed air generation (tool) Stationary compressed air distribution (tool) Individual system 1 Individual system 2 Turbine stabilized air system from incl. air compressor to incl. outlet to turbine Turbine water depression (blow down) air supply system from incl. air compressor to incl. outlet to turbine Pump turbine stabilized air system from incl. air compressor to incl. outlet to turbine Pump turbine water depression (blow down) air supply system from incl. air compressor to incl. outlet to turbine Storage pump stabilized air system from incl. air compressor to incl. outlet to turbine Storage pump water depression (blow down) air supply system from incl. air compressor to incl. outlet to turbine The compressed air systems are in the power plants very differently developed however should this numbering system be kept. AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 54/124 Project: Document No.: KKS - MASTERLIST STANDARD LH-DE011017-REV02 Identification of water supply and disposal systems (G _ _ ) · · · · Raw water supply Drinking water supply Process drainage system Process drains treatment system (GA_) (GK_) (GM_) (GN_) Here will given by the VGB the only following marking, all other ranges are projectspecifically after the KKS key to be specified. GML10 GMM10 GNB10 Dam seepage (leakage) water system Turbine building seepage (leakage) water system Filtering and cleaning system The drainage systems for headrace tunnel (penstock) and machine set are identified as LSL and LSM respectively. Identification of ancillary systems (S _ _ ) Ancillary systems are not direct service to the process in hydro power plants and by the VGB are not continued to give. They are sufficiently defined in the KKS key. · · · · · · · Heating, ventilation air conditioning system (SA_) Stationary air supply (SC_) Fire protection systems (SG_) Waterway facilities (SH_) Cranes (SM_) Elevators (SN_) Workshop, stores, laboratory equipment and staff amenities (ST_) Identification of heavy machinery(X _ _ ) · · Emergency diesel engine plant Emergency generator plant AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 (XJ_) (XK_) C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 55/124 KKS - MASTERLIST Project: Document No.: STANDARD LH-DE011017-REV02 6.1.2 Identification electrical Identification of grid and distribution systems (A _ _ ) Grid and distribution systems are switchyards which transmit the electric power supplied by the power plant to the grid. They start from the high voltage side of the machine transformer and contain circuit breakers, disconnectors, earthing switches, surge voltage protectors, installation units as well as transformers and inductors including the auxiliary systems such as compressed air supply, protection and control systems. The following rules and recommendations have to observed for this purpose. · The process related sections of high voltage switchgear are identical to the switchgear cubicles. · Bus couplers and busbar metering panels should be identified in the numbering section as “00”. · If distinctions necessarily for busbar systems (double busbar) are like that should these done in the number block. 1ADA10 2ADA10 0ADA21 0ADA22 0ADA00 0ADA01 0ADA02 0ADA30 0AFA31 0AFA32 1BAT10 2BAT10 0BCT30 0BFT32 230kV system section machine 1 230kV system section machine 2 230kV system section line 1 230kV system section line 2 230kV system busbar coupling 230kV system busbar system 1 230kV system busbar system 2 230kV system section 66kV supply 66kV system section line 3 66kV system section station service Main transformer unit 1 Main transformer unit 2 Start up transformer Main auxiliary transformer AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 56/124 KKS - MASTERLIST Project: Document No.: STANDARD LH-DE011017-REV02 Identification of power transmission (BA _ ) All installations from excluding the generator terminal to excluding the high voltage side of the generator transformer are part of the power transmission. These cover: · Generator leads including neutral, earthing switch, brake disconnector, surge voltage protector, measuring transducer, earth fault reactors and auxiliary cabinets. · Generator circuit breaker including auxiliary systems and cabinets. · Generator transformer including cooling unit and cabinets The VATECH standard deviates here from the VGB Guideline. The reason is a standardisation of many years in the generator division. The VGB Guideline identify as follows: · The generator leads should be subdivided into subsystems and a decadic numbering in ascending order should be used from excluding the neutral in direction of the generator transformer. · With single pole leads the outer contactor may be identified in the units place. · The interfaces between subsystems should be established according to the devices installed in the leads. The VATECH standard identify as follows: 1BAA10 1BAB10 1BAC10 1BAT10 1MKA10 1MKC10 Generator busduct Generator neutral Generator switchgear Generator transformer Generator Excitation AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 57/124 KKS - MASTERLIST Project: Document No.: STANDARD LH-DE011017-REV02 Identification of low voltage distributions (BF_ till BR_ ) These function levels are not described in the VGB 106 D1. The KKS standard key is to be used as already shown in the example 3.8/10. Identification of battery systems (BT_ ) The VGB does without this function level. This is explained in the next paragraph. VATECH uses however these, because it does not follow the recommendation of the VGB but follows the KKS key (see example 3.8/10). Identification of DC systems (BU_, BV_ ) The VATECH standard deviates here from the VGB Guideline. The VGB Guideline identify as follows: · A separate function level BT_ for batteries and battery chargers is not included. An interdisciplinary code BU_ for the 220VDC system and BV_ for the 24VDC system is recommended so that the functional correlation of the components of a grid system becomes apparent in the identifier, too. Due to use of many years of standard KKS key with VATECH extensions for further voltage levels (110VDC and 48VDC) is not converted this recommendation. (see example 3.8/10) Identification of protection equipment The individual protective functions are generally assigned to the unit which can be protected. Where a higher level protection equipment, which encompasses various units, is to be identified, the classification may be selected from key part “C_ _”. “CH_” generally identifies cubicles for protection equipment. MKY, MLY MKC, MLC B_T A_ _ MY_, CHA U_ _ CYE SG_ Generator protection (e.g. over current, over voltage, impedance, earth fault) Excitation protection (e.g. over excitation, under excitation) Transformer protection (e.g. differential protection, Buchholz protector) Busbar differential protection Unit differential protection Security services (e.g. burglary) Fire alarm system Stationary fire protection system Identification of phase switches The phase switch is classified as BAC in the same manner as the generator circuit breaker. BAC10 BAC20 Generator circuit breaker Phase switch AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 58/124 KKS - MASTERLIST Project: Document No.: STANDARD LH-DE011017-REV02 Identification control and engineering equipment (C_ _ ) Only superordinated systems or several systems are grouped in the function level of "C _ _". If it is a single function control than it is denominated according to their function. Typical are: MEY10DG100 MEY10DE100 MEY10DS100 LNY10DF100 MYB10EY100 BYA10 CBP10 LNA10DL100 Opening control Load control Speed control Discharge control Protective functions (turbine and generator on mechanical failures) Open loop control for auxiliary power supply and emergency power supply Synchronization Level control The control is usually realized over programmable systems, which contain more than one function. Further belong to also diagnostic and monitoring systems as well as operating and monitoring functions. It is to differentiate whether the control is cabinet-oriented or bus-oriented denominated. The VATECH used so far the cabinet-oriented denominating. In the VGB D1 guideline now also the bus-oriented denominating is recommended ("CR_"). This function level is at the moment not in the VATECH KKS key available and if necessary to be inquired. This denomination is often not clearly to be classified due to the multiple functions. The function levels are documented in the VATECH KKS sufficiently. AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 59/124 Project: Document No.: KKS - MASTERLIST STANDARD LH-DE011017-REV02 6.2 Identification of breakdown level 2 The technical equipment e.g. aggregates are classified and numbered here. Identification of subassemblies of the machinery (H_ ) · · The wicket gates are subassemblies of the turbine casing and are identified as “HA” The runner blades are assigned to the runner and therefore they are classified as “HB” MEA20HA010 – MEA20HA180 MEA20AS010 – MEA20AS020 MEA20AS100 Guide vanes Servomotor Operating ring The runner is identified in the same manner as the wicket gate. AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 60/124 Project: Document No.: KKS - MASTERLIST STANDARD LH-DE011017-REV02 Identification of valves (AA) and pipings (BR) There are different starting points possible. The VATECH standard committed itself to the equipment structure and have these very exactly standardized. The VGB guideline however classify it on a functional structure. Thus this structure cannot be converted. The VATECH standard deviates here from the VGB Guideline. The VGB Guideline identify as follows: AA 001…199 Valves in pipings AA 301…399 Valves in measuring circuits (if an identification is required) AA 401…499 Valves in drainage, discharge and flushing pipings AA 501…599 Valves in vent pipings AA 601…699 Valves in sampling pipes AA 701…799 Safety valves BR 001…199 Pipings in general BR 301…399 Measuring pipings (if an identification is required) BR 401…499 Drainage, discharge and flushing pipings BR 501…599 Vent pipings BR 601…699 Sampling pipes BR 701…799 Safety valve pipings The VATECH numberings are shown in the breakdown level 2. Main pipings including the associated valves are numbered in decadic steps. Decade steps take places if the functional group is changed. See example 3.8/6 Secondary pipings are numbered sequentially to the main devices (decade). If subordinated devices are present such as pilot valves, these can be denominated also after the main aggregate with an additional letter such as AA011A. Identification of electrical equipment (G_ ) · Switchgear assemblies The denomination is here aligned to the function of the switchgears. The VATECH standard partly deviates here from the VGB Guideline. VATECH uses for a group only the third digit during the VGB all three digits use. The VGB Guideline identify as follows: GS 0 0 Low voltage switching device 1 Circuit breaker 2 Disconnector 3 Load switch 6 Earthing switch 8 Converter switch 0 1 Busbar 1 2 Busbar 2 3 Busbar 3 4 Busbar 4 6 Bypass busbar 7 Auxiliary busbar 9 Line 0 Number of poles The VATECH numberings are shown in the breakdown level 2. AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 61/124 Project: Document No.: KKS - MASTERLIST STANDARD LH-DE011017-REV02 The single line shall once again clarify the VATECH standard. · Transformation equipment (transformer winding) The following numbering system is only important if the transformer windings are to be differentiated. The transformer is according to standard with GT 100 to denominate. If differentiated between higher and lower voltage side the higher voltage side with 100 and the lower voltage side with 200 are to be denominated. Is it however a multi-winding transformer with same voltage level by 210 and 220, with different by 200 and 300 are to be denominated. AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 62/124 Project: Document No.: KKS - MASTERLIST STANDARD LH-DE011017-REV02 Identification of not electrical measuring circuits (C_ ) Here is also a difference to the VGB guideline VATECH Standard 001 ff analog 301 ff binary 401 ff testing 501 ff local 901 ff virtual VGB guideline 001…099 analog 101…199 binary 301…399 901…999 local virtual See also in breakdown level 2 Multiple tapping points of measuring circuits is shown in example 3.10 Identification of electrical measuring circuits (CE) The numbering system is alike up to the frequency measuring (VGB 401-499). 001…099 101…199 201…299 301…399 501…599 601…699 900…999 Combined measuring Current measuring Voltage measuring Power, resistance, impedance, etc. Frequency measuring Earth fault, phase failure combined calculated measurements See also in breakdown level 2 6.3 Identification of breakdown level 3 Component code The identification divides between electrical and non electric components. Electrical components have a minus in the first digit. Normally two digits for the numbering are used. If necessary it can extended however by one digit. The remaining defaults are sufficiently described in the breakdown level 3. Signal code The structure of the signal code is in chapter 3.5, the exact explanation and the VATECH standard is represented with examples in chapter 5. The letter combinations (chapter 5.1.2) of the VATECH standard deviate not from the VGB guideline, but are only partly more detailed. Likewise the number block in chapter 5.2 respectively in the breakdown level 3. AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 63/124 Project: Document No.: KKS - MASTERLIST STANDARD LH-DE011017-REV02 7 INTEGRATION OF GE (GENERAL ELECTRICS) IDENTIFICATION SYSTEM IN KKS General Electrics, a partner of VA TECH Hydro, uses ANSI (American National Standard Institute) as identification system for power plant components. ANSI is a common used identification system in the United States. To define control and instrumentation interfaces between GE scope of supply and VA TECH HYDRO the GE-identification code is integrated. Consumer and signal codes are integrated as follows: KKS ANSI Breakdown level 0 1 Type of (A) (N) data character (N) _ (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (N) (N) (N) (N) (N) (N) (N) (N) (N) (N) Here breakdown level 0 and breakdown level 1 with the numbering of units, main group and group are indicated. The GE-ANSI code (maximum 10 characters), which is split by an underscore, is added to the KKS. Example: Consumer WT1 Governor oil pump KKS Breakdown level Type of data character ANSI 0 1 1 1 _ 8 8 H Q - 1 Signal code WT1 Governor oil pump running KKS Breakdown level Type of data character ANSI 0 1 1 1 _ 8 8 AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 H Q - 1 C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 64/124 KKS - MASTERLIST Project: Document No.: STANDARD LH-DE011017-REV02 Part II: KKS – Master List Function Key (Breakdown level 1) 66 Main Groups: A B C G L M P Q S U X Z Grid and distribution systems Power transmission and auxiliary power supply Instrumentation and control equipment Water supply and disposal Steam, water, gas cycles Main machine sets Cooling water systems Auxiliary systems Ancillary systems Structures Heavy machinery (not main machine sets) Workshop and office equipment 100 Equipment Unit Key (Breakdown level 2) Main Groups: A B C D E F G H Mechanical equipment Mechanical equipment Direct measuring circuits Closed loop control circuits Analog and binary signal conditioning Indirect measuring circuits Electrical, Instruments and Control equipment Subassemblies of main and heavy machinery Component Key (Breakdown level 3) 112 Main Groups: K M Q X Y Z Electrical components Mechanical components Mechanical components Instrumentation and control components Signal origins Signal applications Gated signals AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 65/124 Project: Document No.: KKS - MASTERLIST STANDARD LH-DE011017-REV02 Function Key (Breakdown level 1) KKSCode Text Remark A GRID AND DISTRIBUTION SYSTEMS GRID AND DISTRIBUTION SYSTEMS AB ABA ABB AC ACA > 420 kV-Systems > 420 kV-System > 420 kV-System 380 (-420) kV-Systems 380 kV-System 420 kV-System 380 kV-System 420 kV-System 220 (-245) kV-Systems 220 kV-System 245 kV-System 220 kV-System 245 kV-System 110 (-150) kV-Systems 110 kV-System 150 kV-System 110 kV-System 150 kV-System 60 (-72) kV-Systems 60 kV-System 72 kV-System 60 kV-System 72 kV-System 45 (-50) kV-Systems 45 kV-System 50 kV-System 45 kV-System 50 kV-System 30 (-35) kV-Systems 30 kV-System 35 kV-System 30 kV-System 35 kV-System 20 (-25) kV-Systems 20 kV-System 25 kV-System 20 kV-System 25 kV-System 10 (-15) kV-Systems 10 kV-System 15 kV-System 10 kV-System 15 kV-System 6 (5) kV-Systems 5 kV-System 6 kV-System 5 kV-System 6 kV-System ACB AD ADA ADB AE AEA AEB AF AFA AFB AG AGA AGB AH AHA AHB AJ AJA AJB AK AKA AKB AL ALA ALB AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 > 420 kV-Systems Unit 1, busbar 1 Unit 2, busbar 2 380 (-420) kV-Systems Unit 1, busbar 1 Unit 2, busbar 2 220 (-245) kV-Systems Unit 1, busbar 1 Unit 2, busbar 2 110 (-150) kV-Systems Unit 1, busbar 1 Unit 2, busbar 2 60 (-72) kV-Systems Unit 1, busbar 1 Unit 2, busbar 2 45 (-50) kV-Systems Unit 1, busbar 1 Unit 2, busbar 2 30 (-35) kV-Systems Unit 1, busbar 1 Unit 2, busbar 2 20 (-25) kV-Systems Unit 1, busbar 1 Unit 2, busbar 2 10 (-15) kV-Systems Unit 1, busbar 1 Unit 2, busbar 2 6 (5) kV-Systems Unit 1, busbar 1 Unit 2, busbar 2 C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 66/124 Project: Document No.: KKS - MASTERLIST AM AMA ANE 1-(3) kV-Systems 1 kV-System 3 kV-System 1 kV-System 3 kV-System < 1 kV-Systems 500V Three-phase-system 660V Three-phase-system 400V Three-phase-system 380V Three-phase-system 220V Alternative voltage switchgear ANF 110V Alternative voltage switchgear ANK ANM 220V Direct voltage switchgear 110V Direct voltage switchgear 125V Direct voltage switchgear 60V Direct voltage switchgear 48V Direct voltage switchgear 24V Direct voltage switchgear 12V Direct voltage switchgear Desk Desk Control desk Main control desk Desk Control desk Main control desk Measuring and metering equipment Measuring equipment Metering equipment Measuring equipment Metering equipment Protection equipment Protection equipment Protection equipment Board Circuit breaker control board Transducer appurtenances Control board for compressed air Control board for hydraulics Automatic board Control board Cabinet for measuring Auxiliary power supply Recording board Metering board Cabinet for protection Cabinet for synchronization Transformation Auxiliary cubicle Indication, manual operation, monitoring Alarm annunciation AMB AN ANA ANB ANQ ANU AP APA APB AQ AQA AQB AR ARA ARB AS ASA ASC ASD ASJ ASM ASN ASP ASQ ASR ASS AST ASU ASW ASX AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 STANDARD LH-DE011017-REV02 1-(3) kV-Systems Unit 1, busbar 1 Unit 2, busbar 2 < 1 kV-Systems Low voltage switchgear 500-1000V, Three-phase alternating current Low voltage switchgear <500V, Three-phase alternating current Low voltage switchgear 220V, single phase alternating current Low voltage switchgear 110V, single phase alternating current Direct voltage switchgear 220V Direct voltage switchgear 110 / or 125V Direct voltage switchgear 60 / or 48V Direct voltage switchgear 24 / or 12V Desks Desk 1 Desk 2 Measuring and metering equipment Equipment for measuring, metering 1 Equipment for measuring, metering 2 Protection equipment Protection equipment (free for use) Protection equipment (free for use) Board and cabinets decentral Circuit breaker appurtenances Transducer appurtenances Compressed air, hydraulics Automatic, control Measuring Auxiliary power supply Recording Metering Protection Synchronization Transformation Panels and cabinets for auxiliary equipment Indication, manual operation, monitoring Alarm annunciation C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 67/124 KKS - MASTERLIST AV AVA AVB AY AYA AYB AYC Marshalling racks Marshalling rack Marshalling rack Communication equipment Telephone system Control console telephone system Alarm system AYD Alarm system AYE AYF AYG AYH AYJ AYK AYP AYQ Fire alarm system Clock system Remote control system Telemetry system Remote metering system HF carrier telephone system Optical monitoring system General gas alarm system (if not assigned to specific system) Radiotelephone system AYS AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 Project: Document No.: STANDARD LH-DE011017-REV02 Marshalling racks Marshalling racks (free for use) Marshalling racks (free for use) Communication equipment Telephone system (PABX) Control console telephone system Alarm system (acoustic) (Separate systems in nuclear power plants as stipulated by KTA (Nuclear Safety Standards Committee)) Alarm system (optical) (Separate systems in nuclear power plants as stipulated by KTA (Nuclear Safety Standards Committee)) Fire alarm system Clock system Remote control system Telemetry system Remote metering system HF carrier telephone system Optical monitoring system General gas alarm system (if not assigned to specific system) Radiotelephone system C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 68/124 KKS - MASTERLIST B POWER TRANSMISSION AND AUXILIARY POWER SUPPLY BA BAA Power transmission Generator leads BAB BAC Generator star point Generator circuit breaker BAT BAU BAX Generator transformer Earthing and lightning protection equipment Fluid supply system for control and protection equipment Protection Medium-voltage distribution BAY BB BBA BBB BBC BBD BBT BBX BBY BC BCA BCT BCX BCY BF BFA BFB BFC BFD BFT BFX BFY .kV Medium voltage distribution .kV Medium voltage distribution .kV Medium voltage distribution .kV Medium voltage distribution Unit transformer (or Auxiliary power transformers) Fluid supply system for control and protection equipment Protection Medium voltage distribution boards and transformers, general-purpose Start-up distribution Start-up transformer Fluid supply system for control and protection equipment Protection Low voltage main distribution 0, .kV Low voltage main distribution 0, .kV Low voltage main distribution 0, .kV Low voltage main distribution 0, .kV Low voltage main distribution 0, .kV Auxiliary transformer Fluid supply system for control and protection equipment Protection AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 Project: Document No.: STANDARD LH-DE011017-REV02 POWER TRANSMISSION AND AUXILIARY POWER SUPPLY Power transmission Generator leads from excl. generator bushings, incl. current- and voltage transformers, cooling and ventilation systems to excl. generator transformer low side bushings or to excl. auxiliary power transformer high side bushings test Foundation cabinets Generator circuit breaker, also commutating pole circuit breaker, incl. cooling system Generator transformers, including cooling system Earthing and lightning protection equipment Fluid supply system for control and protection equipment Electrical control and protection equipment Medium-voltage distribution boards and transformers, normal system Medium voltage distribution 1 normal system Medium voltage distribution 2 normal system Medium voltage distribution 3 normal system Medium voltage distribution 4 normal system Medium voltage auxiliary power transformers Fluid supply system for control and protection equipment Electrical control and protection equipment Medium voltage distribution boards and transformers, general-purpose Medium voltage start-up, offsite, general-purpose distribution Start-up, offsite, general-purpose transformers Fluid supply system for control and protection equipment Protection Low voltage main distribution boards and transformers, normal system Low voltage main distribution 1, normal system Low voltage main distribution 2, normal system Low voltage main distribution 3, normal system Low voltage main distribution 4, normal system Low voltage auxiliary power transformers Fluid supply system for control and protection equipment Protection C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 69/124 KKS - MASTERLIST BH BHA BHB BHC BHD BHT BHX BHY BJ BJA BJB BJC BJD BJT BJX BJY BL BLA BLB BLC BLH BLT BLX BLY BM BMA BMH BMT BMX BMY Project: Document No.: STANDARD LH-DE011017-REV02 Low voltage main distribution Low voltage main distribution boards and transformers, general-purpose 0, .kV Low voltage main distribution Low voltage main distribution 1 general purpose 0, .kV Low voltage main distribution Low voltage main distribution 2 general purpose 0, .kV Low voltage main distribution Low voltage main distribution 3 general purpose 0, .kV Low voltage main distribution Low voltage main distribution 4 general purpose Low voltage auxiliary power transformers Low voltage auxiliary power transformers Fluid supply system for control and protection Fluid supply system for control and protection equipment equipment Protection Electrical control and protection equipment Low voltage subdistribution Low voltage subdistribution boards and transformers, normal system 0, .kV Low voltage subdistribution Low voltage subdistribution 1 normal system Water turbine 0, .kV Low voltage subdistribution Low voltage subdistribution 2 normal system 0, .kV Low voltage subdistribution Low voltage subdistribution 3 normal system 0, .kV Low voltage subdistribution Low voltage subdistribution 4 normal system Low voltage auxiliary power transformers Low voltage auxiliary power transformers Fluid supply system for control and protection Fluid supply system for control and protection equipment equipment Protection Electrical control and protection equipment Low voltage subdistribution Low voltage subdistribution boards and transformers, general-purpose 0, .kV Low voltage subdistribution Low voltage subdistribution 1 general purpose Lightning 0, .kV Low voltage subdistribution Low voltage subdistribution 2 general purpose 0, .kV Low voltage subdistribution Low voltage subdistribution 3 general purpose 0,. kV subdistribution boards Low voltage subdistribution boards, generalpurpose (free for use) Low voltage auxiliary power transformers Low voltage auxiliary power transformers Fluid supply system for control and protection Fluid supply system for control and protection equipment equipment Protection Electrical control and protection equipment Low voltage distribution (diesel) emergency Low voltage distribution boards and power system transformers, (diesel) emergency power system 1 Low voltage emergency distribution board Low voltage emergency distribution boards (emergency diesel) Low voltage emergency distribution board Emergency lightning and emergency distribution Low voltage emergency power transformers Low voltage emergency power transformers Fluid supply system for control and protection Fluid supply system for control and protection equipment equipment Protection Electrical control and protection equipment AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 70/124 KKS - MASTERLIST BP Power installations for electrical variablespeed drives BPA Frequency converter BPT Excitation transformer BPX BRY BT BTA BTB BTC BTD BTE BTF BTL Fluid supply system for control and protection equipment Protection Low voltage distribution, uninterruptible power supply 230V UPS-Emergency current distribution 1 230V AC Safe busbar 230V UPS-Emergency current distribution 2 230V AC Safe busbar AC-Converter Fluid supply system for control and protection equipment Protection Battery system 220V Battery 1 220V Battery 2 110/125V Battery 1 110/125V Battery 2 24/48V Battery 1 24/48V Battery 2 220V Battery charger 1 BTM 220V Battery charger 2 BTN 110/125V Battery charger 1 BTP 110/125V Battery charger 2 BTQ 24/48V Battery charger BTR 24/48V Battery charger BU Direct voltage distribution, normal system BUA BUB BUC 220V Direct current distribution board 1 220V Direct current distribution board 2 110/125V Direct current distribution board, common part 110/125V Direct current distribution board, common part, fail safe 24/48V Direct current distribution board 1 24/48V Direct current distribution board 2 24/48V Direct current distribution board, common part Fluid supply system for control and protection equipment Protection BPY BR BRA BRB BRU BRX BUD BUE BUF BUH BUX BUY AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 Project: Document No.: STANDARD LH-DE011017-REV02 Power installations for variable-speed drives (e.g. for feedwater pump, excitation equipment, not power adjusters in switchgear) Power installations for variable-speed drives (free for use) Power installations for variable-speed drives (free for use) Fluid supply system for control and protection equipment Electrical control and protection equipment Low voltage distribution boards, uninterruptible (converter) power supply Low voltage distribution boards, uninterruptible (converter) power supply Low voltage distribution boards, uninterruptible (converter) power supply Converter (static), inverter Fluid supply system for control and protection equipment Electrical control and protection equipment Battery system Batteries (free for use according to voltage level) Batteries (free for use according to voltage level) Batteries (free for use according to voltage level) Batteries (free for use according to voltage level) Batteries (free for use according to voltage level) Batteries (free for use according to voltage level) Rectifiers, battery chargers (free for use according to voltage level) Rectifiers, battery chargers (free for use according to voltage level) Rectifiers, battery chargers (free for use according to voltage level) Rectifiers, battery chargers (free for use according to voltage level) Rectifiers, battery chargers (free for use according to voltage level) Rectifiers, battery chargers (free for use according to voltage level) Direct voltage distribution boards, normal system Direct voltage distribution boards, normal system Direct voltage distribution boards, normal system 110V Direct current distribution board, common part 110V Direct current distribution board, common part, fail safe 24V Direct current distribution board 1 24V Direct current distribution board 2 24V Direct current distribution board, common part Fluid supply system for control and protection equipment Electrical control and protection equipment C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 71/124 KKS - MASTERLIST C Project: Document No.: STANDARD LH-DE011017-REV02 INSTRUMENTATION AND CONTROL INSTRUMENTATION AND CONTROL EQUIPMENT (Identification on a priority basis EQUIPMENT CA CAA CAB CAC CAD CAE CB CBA CBB CBC CBD CBE CBF CBP CBQ CE CEJ CF CFA CFB CFC CFD CFQ CG CGA CGB CH CHA Protective interlock Cabinet for protective interlock Cabinet for protective interlock Cabinet for protective interlock Cabinet for protective interlock Cabinet for protective interlock Functional group control, Subloop control Turbine control cabinet Generator control cabinet Auxiliary control cabinet Control cabinet 4 Control cabinet 5 Control cabinet 6 Cabinet for synchronization Cabinet for auxiliary power changeover Annunciation Fault recording Measurement, recording Cabinet 1 for measurement Cabinet 2 for measurement Cabinet 3 for measurement Cabinet 4 for measurement Cabinet for metering Closed-loop control Closed-loop control cabinet Closed-loop control cabinet Protection Cabinets for protection system 1 CHB Cabinets for protection system 2 CHC Cabinets for protection system 3 CHD Cabinets for protection system 4 CHY Protection AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 according to main instrumentation and control function also acceptable in composite structure hardware packaging systems.) Protective interlock Cabinets for protective interlocks (free for use) Cabinets for protective interlocks (free for use) Cabinets for protective interlocks (free for use) Cabinets for protective interlocks (free for use) Cabinets for protective interlocks (free for use) Functional group control, Subloop control Cabinets for functional group control (free for use) Cabinets for functional group control (free for use) Cabinets for functional group control (free for use) Cabinets for functional group control (free for use) Cabinets for functional group control (free for use) Cabinets for functional group control (free for use) Cabinets for synchronization Cabinets for auxiliary power changeover Annunciation Fault recording, recorder Measurement, recording Cabinets for measurement (free for use) Cabinets for measurement (free for use) Cabinets for measurement (free for use) Cabinets for measurement (free for use) Cabinets for recording (meters, pen recorders) Closed-loop control (excl. power section) Cabinets for closed-loop control (free for use) Cabinets for closed-loop control (free for use) Protection (excl. reactor protection) Cabinets for generator and transformer protection (free for use) Cabinets for generator and transformer protection (free for use) Cabinets for generator and transformer protection (free for use) Cabinets for generator and transformer protection (free for use) Protection, emergency stop cabinet C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 72/124 KKS - MASTERLIST CJ CJA CJD Unit coordination level Unit control system Start-up control, setpoint control CK CKA Process computer system Supervisory and diagnostic computer 1 CKB Supervisory and diagnostic computer 2 CKC Supervisory and diagnostic computer 3 CKF CKM CKN CKP CKQ CM Process computer joint control Patrol monitoring system Process computer system 1 Process computer system 2 Process computer system 3 Instrumentation and control equipment CMA Instrumentation and control system 1 CMB Instrumentation and control system 2 CMC Instrumentation and control system 3 CMD Instrumentation and control system 4 CV Marshalling rack CVA CVB CVC CVD CVG CVM CVP CVQ CW CWA CWB CWC CWD CWF Marshalling rack, system 1 Marshalling rack, system 2 Marshalling rack, system 3 Marshalling rack, system 4 Marshalling rack Marshalling rack Marshalling rack Marshalling rack Control room Main control console 1 Main control console 2 Main control console 3 Plotter table Main control panels 1 AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 Project: Document No.: STANDARD LH-DE011017-REV02 Unit coordination level Unit control system (including cabinets) Start-up control, setpoint control (unit) (incl. cabinet) Process computer system Online supervisory and diagnostic computer (free for use) Online supervisory and diagnostic computer (free for use) Online supervisory and diagnostic computer (free for use) Process computer joint control Access control computer (free for use) Process computer system (free for use) Process computer system (free for use) Process computer system (free for use) Instrumentation and control equipment (free for use for system combination) Note: control stations has to be defined by the counting Nos., the marshalling racks shall fit to these Nos. e.g. 01CMA01GS001-5 and 01CVA01GS… Instrumentation and control equipment (free for use for system combination) Instrumentation and control equipment (free for use for system combination) Instrumentation and control equipment (free for use for system combination) Instrumentation and control equipment (free for use for system combination) Marshalling racks (cabinet); the marshalling racks shall fit to control station Nos., e.g. 01CMA01GS001-5 and 01CVA01GS… Marshalling racks (cabinets) Marshalling racks (cabinets) Marshalling racks (cabinets) Marshalling racks (cabinets) Marshalling rack water treatment system Marshalling rack heavy machinery, generator Marshalling rack cooling water system Marshalling rack auxiliary plant Control rooms Main control consoles fits to *CMA* and *CVA* Main control console fits to *CMB* and *CVB* Main control console fits to *CMC* and *CVC* Main control console for matrix, plotter, hardcopy Main control panels (screens), fits to *CMA/CVA* C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 73/124 KKS - MASTERLIST CX CXA CXC CXD CXG CXM CXP CY CYA CYB CYC CYD CYE CYF CYG CYH CYJ CYK CYL CYP CYQ CYR CYS CYT CYU CYV Project: Document No.: STANDARD LH-DE011017-REV02 Local control station Local control stations (e.g. for coal handling plants, ash handling plants, cooling water systems, diesel units, supervision of generator cooling, remote shutdown station) Local control station turbine Local control station, locally, turbine terminal box Local control station water treatment system Local control station Local control station diesel engine plant Local control station Local control station process drainage system Local control station Local control station generator Local control station, locally Local control station cooling water system Local control station, locally Communication equipment Communication equipment Telephone system (PABX) Telephone system (PABX) Control console telephone system in the unit control room Alarm system (acoustic) Alarm system (acoustic) Alarm system (optical) Alarm system (optical) Fire alarm system Fire alarm system Clock system Radio-, satellite clock system Remote control system Remote control system Telemetry system Telemetry system Remote metering system Remote metering system HF carrier telephone system HF carrier telephone system Staff paging system Staff paging system Optical monitoring system for outdoor structures Gas detection system Gas detection system Pneumatic tube conveyor Pneumatic tube conveyor Radiotelephone system Radiotelephone system Intrusion detection system Intrusion detection system Access control system Access control system Plant and production management system Plant and production management system AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 74/124 KKS - MASTERLIST G WATER SUPPLY AND DISPOSAL GA GAA Raw water supply Extraction, mechanical cleaning GAC Piping and channel system GAD Storage system GAF Pump system GAV GAX Lubricant supply system Fluid supply system for control and protection equipment Control and protection equipment GAY GH GHC GHD GK GKA GKB GKC GKD Distribution systems (not drinking water) Distribution systems after treatment (demineralization) Distribution systems after treatment (others) Drinking water supply Receiving point Storage, forwarding, distribution system Drinking water supply Drinking water distribution GKE Drinking water supply GKF Drinking water supply GKG Drinking water supply GKH Drinking water supply GKJ Drinking water supply GKX Fluid supply system for control and protection equipment Protection GKY AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 Project: Document No.: STANDARD LH-DE011017-REV02 WATER SUPPLY AND DISPOSAL Raw water supply Extraction, mechanical cleaning from incl. intake to incl. mechanical cleaning system outlet Piping and channel system from excl. intake or from excl. outlet of other system to excl. inlet to other system Storage system from incl. storage system inlet to incl. storage system outlet, incl. intake and outfall Pump system from incl. pump system suction nozzle to incl. pump system discharge nozzle Lubricant supply system Fluid supply system for control and protection equipment Control and protection equipment. Only for mechanical equipment (pneumatic or hydraulic) Distribution systems (not drinking water) tanks Distribution systems after treatment (others) Drinking water supply Receiving point Storage, forwarding, distribution system Drinking water supply Drinking water supply (free for use e.g. buildingspecific) Drinking water supply (free for use e.g. buildingspecific) Drinking water supply (free for use e.g. buildingspecific) Drinking water supply (free for use e.g. buildingspecific) Drinking water supply (free for use e.g. buildingspecific) Drinking water supply (free for use e.g. buildingspecific) Fluid supply system for control and protection equipment Electrical control and protection equipment C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 75/124 KKS - MASTERLIST GM GMA Process drainage system Process drainage system GMB Process drainage system GMC Process drainage system GMD Process drainage system GME Process drainage system GMF Process drainage system GMG GMH GML GMM GMP GMT GMX Process drainage system Process drainage system Process drainage system Process drainage system Process drainage system Process drainage system Fluid supply system for control and protection equipment Protection Process drains treatment system Filtering, mechanical cleaning system Lubricant supply system Fluid supply system for control and protection equipment Control and protection equipment GMY GN GNB GNV GNX GNY AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 Project: Document No.: STANDARD LH-DE011017-REV02 Process drainage system Process drainage system (free for use e.g. building-specific) Process drainage system (free for use e.g. building-specific) Process drainage system (free for use e.g. building-specific) Process drainage system (free for use e.g. building-specific) Process drainage system (free for use e.g. building-specific) Process drainage system (free for use e.g. building-specific) GT wash water Boiler house Dam Power house Pump house Sprinkler system Fluid supply system for control and protection equipment Electrical control and protection equipment Process drains treatment system Filtering, mechanical cleaning system Lubricant supply system Fluid supply system for control and protection equipment Control and protection equipment. Only for mechanical equipment (pneumatic or hydraulic) C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 76/124 KKS - MASTERLIST L STEAM, WATER, GAS CYCLES LN LNA Water impounding works for hydroelectric power plant Water level metering LNB LNC LND LNE LNF Trash rack, trash/fish barrier Dam, weir system Spillway Drainage system Pump system LNV LNW Lubricant supply system Sealing water supply system LNX LPA Fluid supply system for control and protection equipment Protection Intake system, upperwater system for hydroelectric powerplant Rake and rake cleaning system LPB LPC Isolating equipment Piping and penstock system LPE LPV LPW Surge tank Lubricant supply system Sealing water supply system LPX Fluid supply system for control and protection equipment Protection Tail race system, underwater system for hydroelectric power plant Underwater piping and culvert system Surge tank Isolating equipment Rake and rake cleaning system for pumpedstorage operation Lubricant supply system Sealing water supply system LNY LP LPY LQ LQA LQB LQC LQE LQV LQW LQX LQY LS LSL Fluid supply system for control and protection equipment Protection Common installations for hydroelectric power plant Drainage system AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 Project: Document No.: STANDARD LH-DE011017-REV02 STEAM, WATER, GAS CYCLES Water impounding works for hydroelectric power plant Water level metering at the water impounding work Trash rack, trash/fish barrier Dam, weir system Spillway Drainage system Pump system within the storage system (upper water) Lubricant supply system from incl. sealing water supply main isolating valve to excl. casing nozzle of sealing water user Fluid supply system for control and protection equipment Electrical control and protection equipment Intake system, upperwater system for hydroelectric powerplant Separate out and collect floating matter from headrace Isolating equipment from incl. receiving point to incl. discharge into turbine system, incl., connecting piping for pump system Surge tank Lubricant supply system from incl. sealing water supply main isolating valve to excl. casing nozzle of sealing water user Fluid supply system for control and protection equipment Electrical control and protection equipment Tail race system, underwater system for hydroelectric power plant Underwater piping and culvert system Surge tank Isolating equipment Rake and rake cleaning system for pumpedstorage operation Lubricant supply system from incl. sealing water supply main isolating valve to excl. casing nozzle of sealing water user Fluid supply system for control and protection equipment Electrical control and protection equipment Common installations for hydroelectric power plant Drainage system C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 77/124 KKS - MASTERLIST M ME MEA MEB MED MEG MEK MEL MES MEV MEW MEX MEY MF MFA MFB MFD MFG MFK MFL MFM MFS MFV MFW MFX MFY Project: Document No.: STANDARD LH-DE011017-REV02 MAIN MACHINE SETS MAIN MACHINE SETS Hydraulic turbine plant Hydraulic turbine plant Turbine (casing, shaft, runner etc.) Turbine from excl. turbine inlet or from excl. inlet valve to incl. turbine outlet or to excl. isolating valve, incl. draft tube Isolating valve blocking headwater before turbine MEA and/or setting headwater for turbine MEA Bearings Bearings Stabilizing air system Stabilizing air system from incl. air compressor to incl. outlet to turbine Gear Transmission gear between prime mover and driven machine, incl. turning gear, barring gear Water depression air supply system from incl. air compressor to incl. outlet to turbine Shaft gland cooling water system Shaft gland cooling water system Lubricant supply system from incl. lubricant tank to excl. user and from excl. user Sealing water supply system from incl. sealing water supply main isolating valve to excl. casing nozzle of sealing water user Hydraulic oil Non-electric control and protection equipment, incl. fluid supply system Protection Electrical control and protection equipment Pumping turbine plant in pumped-storage Pumping turbine plant in pumped-storage power plants power plants Pumping turbine, pump and turbine as integral Pumping turbine, pump and turbine as integral unit unit Isolating valve blocking water before turbine MFA and/or setting water for turbine MFA Bearings Bearings Stabilizing air system Stabilizing air system from incl. air compressor to incl. outlet to turbine Gear Transmission gear between motor generator set and pumping turbine Water depression air supply system from incl. air compressor to incl. outlet to turbine Start-up unit Start-up unit Shaft gland cooling water system Shaft gland cooling water system Lubricant oil supply Lubricant supply system from incl. dedicated lubricant tank or coon lubricant and control fluid tank or from excl. branch off control fluid supply system to excl. user from excl. user Sealing fluid system Sealing fluid supply system Control oil Fluid supply system for control and protection equipment Control and protection equipment Control and protection equipment. Only for mechanical equipment (pneumatic or hydraulic) AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 78/124 KKS - MASTERLIST MG MGA MGB Pumped-storage plant Storage pump (casing, shaft, runner etc.) Isolating valve MGD MGG MGK Bearings Stabilizing air system Gear MGL MGM MGS MGV Water depression air supply system Start-up unit Shaft gland cooling water system Lubricant oil supply MGW MGX Sealing fluid system Control oil MGY Control and protection equipment AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 Project: Document No.: STANDARD LH-DE011017-REV02 Pumped-storage plant Storage pump (casing, shaft, runner etc.) blocking water before storage pump MGA and/or setting water for storage pump MGA Bearings Stabilizing air system Transmission gear between motor generator set and storage pump from incl. air compressor to incl. outlet to turbine Start-up unit Shaft gland cooling water system Lubricant supply system from incl. dedicated lubricant tank or coon lubricant and control fluid tank or from excl. branch off control fluid supply system to excl. user from excl. user Sealing fluid supply system Fluid supply system for control and protection equipment Control and protection equipment. Only for mechanical equipment (pneumatic or hydraulic) C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 79/124 KKS - MASTERLIST MJ MJA Diesel engine plant Engine MJB Turbocharger, blower MJG Liquid cooling system MJH Air intercooling system MJK Gear MJN Fuel system MJP MJQ Start-up unit Air intake system MJR Exhaust gas system MJV Lubricant oil supply MJW MJX Sealing fluid system Control oil MJY Control and protection equipment AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 Project: Document No.: STANDARD LH-DE011017-REV02 Diesel engine plant Engine from incl. fuel injection nozzle inlet or from incl. air intake nozzles or from incl. cooling water inlet nozzles to incl. exhaust nozzle outlet or to incl. cooling water nozzle outlet, incl. engineinternal systems Turbocharger, blower from incl. turbocharger or blower inlet to incl. turbocharger or blower outlet Liquid cooling system from excl. engine cooling water nozzle outlet or from incl. turbocharger air cooling system inlet to excl. engine cooling water nozzle inlet or to incl. turbocharger air cooler outlet Air intercooling system from incl. intercooler inlet to incl. intercooler outlet to excl. outlet to other cooling systems Transmission gear between prime mover and driven machine Fuel systems from incl. temporary (day) tank or from excl. branch off piping system to excl. fuel injection nozzle inlet Start-up unit (incl. flywheel) Air intake system from excl. atmosphere to excl. turbocharger or to excl. engine air intake nozzles Exhaust gas system from excl. engine exhaust nozzle outlet to excl. discharge into atmosphere Lubricant supply system from incl. dedicated lubricant tank or coon lubricant and control fluid tank or from excl. branch off control fluid supply system to excl. user from excl. user Sealing fluid supply system Fluid supply system for control and protection equipment Control and protection equipment. Only for mechanical equipment (pneumatic or hydraulic) C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 80/124 KKS - MASTERLIST MK MKA Generator plant Generator casing MKB Excitation MKC Excitation MKD Bearings Bearing pedestal Thrust bearing MKF Stator/rotor cooling system MKG Stator/rotor cooling system MKH Stator/rotor cooling system MKJ Stator/rotor cooling system MKQ Exhaust gas system MKU Stator/rotor cooling system MKV Lubricant supply system MKW Sealing fluid supply MKX Control air Control oil Control and protection equipment MKY AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 Project: Document No.: STANDARD LH-DE011017-REV02 Generator plant Generator, complete, incl. stator, rotor and all integral cooling equipment to incl. generator bushing Generator exciter set, even with electric generatorbrake (use only if *MKC* is not sufficient for identification) Generator exciter set, even with electric generatorbrake Bearings Standard application is: MKD10 = bearing pedestal driven end (DE) MKD20 = bearing pedestal excitation end (EE) Stator/rotor liquid cooling system, incl. coolant supply system (Note: for cooling oil see *MKU*) Task: dissipate heat produced by stator/rotor to coolant, from excl. stator/rotor outlet to excl. stator/rotor inlet Stator/rotor hydrogen cooling system, incl. coolant supply system Task: dissipate heat produced by stator/rotor to coolant, from excl. stator/rotor outlet to excl. stator/rotor inlet Stator/rotor nitrogen / carbon dioxide cooling system, incl. coolant supply system Task: dissipate heat produced by stator/rotor to coolant, from excl. stator/rotor outlet to excl. stator/rotor inlet Stator/rotor air cooling system, incl. coolant supply system Task: dissipate heat produced by stator/rotor to coolant from excl. stator/rotor outlet to excl. stator/rotor inlet Exhaust gas system (if separate from *MKG* and *MKH*) Stator/rotor cooling oil cooling system, incl. coolant supply system (Note: for other liquid cooling see *MKF*) Task: dissipate heat produced by stator/rotor to coolant from excl. stator/rotor outlet to excl. stator/rotor inlet Lubricant supply system (if separate system for generator) Sealing fluid supply system (Sealing oil system, incl. supply and treatment) from excl. branch off sealing oil supply system to excl. stator inlet and from excl. stator outlet to excl. inlet to other system or in closed systems from excl. stator outlet Fluid supply system for control and protection equipment Control and protection equipment C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 81/124 KKS - MASTERLIST ML MLA Electro-motive plant Motor generator, complete, incl. stator, rotor and all integral cooling equipment MLC Excitation MLD Bearings Bearing pedestal Thrust bearing MLF Stator/rotor cooling system MLG Stator/rotor cooling system MLH Stator/rotor cooling system MLJ Stator/rotor cooling system MLQ Exhaust gas system MLU Stator/rotor cooling system MLV Lubricant supply system MLW Sealing fluid supply MLX Control air Control oil Control and protection equipment MLY AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 Project: Document No.: STANDARD LH-DE011017-REV02 Motor generator plant Motor generator, complete, incl. stator, rotor and all integral cooling equipment to incl. generator bushing Motor generator exciter set, even with electric generator-brake Bearings Standard application is: MLD10 = bearing pedestal driven end (DE) MLD20 = bearing pedestal excitation end (EE) Stator/rotor liquid cooling system, incl. coolant supply system (Note: for cooling oil see *MLU*) Task: dissipate heat produced by stator/rotor to coolant, from excl. stator/rotor outlet to excl. stator/rotor inlet Stator/rotor hydrogen cooling system, incl. coolant supply system Task: dissipate heat produced by stator/rotor to coolant, from excl. stator/rotor outlet to excl. stator/rotor inlet Stator/rotor nitrogen / carbon dioxide cooling system, incl. coolant supply system Task: dissipate heat produced by stator/rotor to coolant, from excl. stator/rotor outlet to excl. stator/rotor inlet Stator/rotor air cooling system, incl. coolant supply system Task: dissipate heat produced by stator/rotor to coolant from excl. stator/rotor outlet to excl. stator/rotor inlet Exhaust gas system (if separate from *MLG* and *MLH*) Stator/rotor cooling oil cooling system, incl. coolant supply system (Note: for other liquid cooling see *MLF*) Task: dissipate heat produced by stator/rotor to coolant from excl. stator/rotor outlet to excl. stator/rotor inlet Lubricant supply system (if separate system for generator) Sealing fluid supply system (Sealing oil system, incl. supply and treatment) from excl. branch off sealing oil supply system to excl. stator inlet and from excl. stator outlet to excl. inlet to other system or in closed systems from excl. stator outlet Fluid supply system for control and protection equipment Control and protection equipment C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 82/124 KKS - MASTERLIST MM MMA MMC MMD MME MMF MMG MMH MMV MMW MMX MMY MP MPA MPB MPG MPR MPS MV MVA MVB MVC MX MXA MXB MXC MY MYA MYB MYC Project: Document No.: STANDARD LH-DE011017-REV02 Compressor plant Compressor Compressor plant Compressor incl. internal systems from incl. air, cooling fluid inlet to incl. air, cooling fluid outlet Air intake piping system Air intake piping system Air intake from excl. atmosphere Air intake piping to excl. compressor inlet Bearings Bearings Intercooling system Intercooling system Recooling system (After cooling) After cooling system Final cooling system Final cooling system Discharge piping system Discharge piping system from excl. compressor outlet to excl. inlet to other system Lubricant oil, Lubricant oil supply Lubricant supply system Sealing oil, Sealing oil supply Sealing fluid supply system Control air, Control oil Fluid supply system for control and protection equipment Control and protection equipment Control and protection equipment Common installations for main machine set Common installations for main machine sets Foundation Foundation Casing Casing, Cover Frame, support structure Frame, support structure Forced cooling system Forced cooling system Drying and conservation system Drying and conservation system Lubricant oil, Lubricant oil supply Lubricant supply system Lubricant oil, Lubricant oil supply Lubricant supply system (free for use) Lubricant oil, Lubricant oil supply Lubricant supply system (free for use) Lubricant oil, Lubricant oil supply Lubricant supply system. (free for use) Control air, Control oil Fluid supply system for control and protection equipment Control air, Control oil Fluid supply system for control and protection equipment (free for use) Control air, Control oil Fluid supply system for control and protection equipment (free for use) Control air, Control oil Fluid supply system for control and protection equipment (free for use) Control and protection equipment Control and protection equipment Control and protection equipment Control and protection equipment (free for use) Control and protection equipment Control and protection equipment (free for use) Control and protection equipment Control and protection equipment. (free for use) AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 83/124 KKS - MASTERLIST P COOLING WATER SYSTEMS PA PAA Main cooling water system Extraction, mechanical cleaning for direct cooling Raw water intake Raw water screening Main cooling water piping and culvert system PAB PAC Main cooling water pump system PAD Cooling tower PAE PAH PAR Cooling tower pumps Condenser cleaning system Condenser tube cleaning system Make-up water piping system PAS Make-up water pump system PAV PAX Lubricant oil, Lubricant oil supply Control air, Control oil PAY PB PC Control and protection equipment Main cooling water treatment system Secondary cooling water system, conventional area Extraction, mechanical cleaning for direct cooling PCA PCB Piping and culvert system Canal (Culvert) PCC Pump system Secondary cooling water pumps PCD PCM CCCW cooler Service (secondary cooling) water system for generator, motor generator cooling PCV PCX Lubricant oil, Lubricant oil supply Control air, Control oil Control and protection equipment PCY AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 Project: Document No.: STANDARD LH-DE011017-REV02 COOLING WATER SYSTEMS Circulating (main cooling) water system Extraction, mechanical cleaning for direct cooling from incl. intake system to incl. mechanical cleaning system outlet Circulating (main cooling) water piping and culvert system from excl. outlet of circulating (main cooling) water extraction system (excl. any user) to incl. Outfall in direct cooling system or from excl. cooling tower outlet to excl. cooling tower inlet Circulating (main cooling) water pump system from incl. pump system suction nozzle to incl. pump system discharge nozzle Recirculating cooling system, outfall cooling system from incl. hot water riser to incl. basin outlet Cooling tower pump system (if separate) Condenser cleaning system, incl. all appurtenances Make-up water piping system from excl. intake to excl. inlet to other system Make-up water pump system from incl. pump system suction nozzle to incl. pump system discharge nozzle Lubricant supply system Fluid supply system for control and protection equipment Control and protection equipment Main cooling water treatment system Service (secondary cooling) water system, conventional area Extraction, mechanical cleaning for direct cooling from incl. intake system to incl. Mechanical cleaning system outlet Piping and culvert system from excl. outlet of service (secondary cooling) extraction system or from excl. branch off circulating water system to excl. inlet to other system, excl. respective user and from excl. make-up water treatment and distribution Pump system from incl. pump system suction nozzle to incl. pump system discharge nozzle Recirculation cooling system, outfall cooling system Secondary cooling water system for generator, motor generator cooling from excl. branch off *PCB* to excl. generator cooler and from excl. generator cooler to excl. inlet to *PCB* or other systems Lubricant supply system Fluid supply system for control and protection equipment Control and protection equipment C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 84/124 KKS - MASTERLIST PG PGA PGB PGC Closed cooling water system Filter Mechanical cleaning Piping Distribution system Closed cooling water pumping system PGM Cooling water system (CCCW) for generator, motor generator cooling PGY PU PUA Protection Common equipment for cooling water system Common equipment for cooling water system PUB Common equipment for cooling water system PUC Common equipment for cooling water system PUK PUN Neutralization Proportioning system AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 Project: Document No.: STANDARD LH-DE011017-REV02 for conventional area Closed cooling water system for conventional area (free for use) Closed cooling water system for conventional area (free for use) Closed cooling water system for conventional area (free for use) Secondary cooling water system for generator, motor generator cooling from excl. branch off *PGB* to excl. generator cooler and from excl. generator cooler to excl. inlet to *PGB* or other systems If not *PCM*! Electrical control and protection equipment Common equipment for cooling water systems Common equipment for cooling water systems (free for use) Common equipment for cooling water systems (free for use) Common equipment for cooling water systems (free for use) Neutralization Proportioning system C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 85/124 KKS - MASTERLIST Q AUXILIARY SYSTEMS QC QCA Central chemicals supply Central chemicals supply QCB Central chemicals supply QCD Central chemicals supply QCF Central chemicals supply QE General compressed air and carrier air supply Central compressed air and carrier air generation system Central compressed air and carrier air distribution system General compressed air and carrier air supply (free for use) General compressed air and carrier air supply (free for use) Lube oil, Lube oil supply Fluid supply system for control and protection equipment Control and protection equipment General control air supply Central control air generation system General control air supply, Compressed air Instrument air Receiver, storage Adsorbtion Dryer Lube oil, Lube oil supply Fluid supply system for control and protection equipment Control and protection equipment Central oil supply and disposal system Oil regeneration system QEA QEB QEC QED QEV QEX QEY QF QFA QFB QFC QFD QFV QFX QFY QS QSA AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 Project: Document No.: STANDARD LH-DE011017-REV02 AUXILIARY SYSTEMS Central chemicals supply Central chemicals supply (free for use e.g. building specific) Central chemicals supply (free for use e.g. building specific) Central chemicals supply (free for use e.g. building specific) Central chemicals supply (free for use e.g. building specific) General compressed air and carrier air supply Central compressed air and carrier air generation system Central compressed air and carrier air distribution system General compressed air and carrier air supply (free for use) General compressed air and carrier air supply (free for use) Lubricant supply system Fluid supply system for control and protection equipment Control and protection equipment General control air supply Central control air generation system Central control air distribution system General control air supply (free for use) General control air supply (free for use) Lubricant supply system Fluid supply system for control and protection equipment Control and protection equipment Central oil supply and disposal system Oil regeneration system C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 86/124 KKS - MASTERLIST S SA SAB SAC SAG SAH SAL SAM ANCILLARY SYSTEMS Heating, ventilation, air-conditioning (HVAC) systems for conventional area Heating, ventilation, air-conditioning (HVAC) systems for conventional area Heating, ventilation, air-conditioning (HVAC) systems for conventional area Heating, ventilation, air-conditioning (HVAC) systems for conventional area Heating, ventilation, air-conditioning (HVAC) systems for conventional area Heating, ventilation, air-conditioning (HVAC) systems for conventional area SB SBA SBB Heating, ventilation, air-conditioning (HVAC) systems for conventional area Heating, ventilation, air-conditioning (HVAC) systems for conventional area Space heating systems Space heating system Space heating system SBE Space heating system SBL Space heating system SC Stationary compressed air supplies SCA Compressed air generation system SCB Compressed air distribution system SCC SCD SD Vessel for compressed air Dryer Stationary cleaning systems SDA Stationary cleaning system SDD GT Washwater system GT Washwater skid GT Washwater unit SAP AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 Project: Document No.: STANDARD LH-DE011017-REV02 ANCILLARY SYSTEMS Room ventilation Heating, ventilation, air-conditioning (HVAC) systems Heating, ventilation, air-conditioning (HVAC) systems Heating, ventilation, air-conditioning (HVAC) systems Heating, ventilation, air-conditioning (HVAC) systems (boiler house) Heating, ventilation, air-conditioning (HVAC) systems acoustical enclosure (off base enclosure) intake air, Exhaust air antiicing air Heating, ventilation, air-conditioning (HVAC) systems (machine hall) Heating, ventilation, air-conditioning (HVAC) systems (cooling water system) Space heating systems Heating system (heating control room) Space heating systems (free for use e.g. building specific) Space heating systems (internal heating system, district heating) Space heating systems (internal heating system, district heating) Note: only if separate service air exist to the instrument-air Note: only if separate service air compressor plant to the I-air compressor plant exist. If only one common compressor plant exist, then the KKS for the I-air is valid. Starts with branch of air compressor plant/distribution Vessel for compressed service air Dryer for service air Stationary cleaning systems (see *FK* for decontamination systems) Stationary cleaning systems (see *FK* for decontamination systems) (Wash water, rotary air preheater) Stationary cleaning systems (see *FK* for decontamination systems) (GT Wash water unit) C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 87/124 KKS - MASTERLIST SG SGA SGC SGE SGF SGG SGH SGJ SGK Stationary fire protection systems Fire water system, conventional area Spray deluge systems, conventional area Sprinkler systems Foam fire-fighting systems Tank roof, tank shell cooling systems Nitrogen fire-fighting system CO2 fire-fighting systems Halon fire-fighting systems SGL SGX SGY Powder fire-fighting systems Fluid supply system for control and protection equipment Control and protection equipment SH SHA Waterway facilities Intake system SHB Lock chamber SHC SHD SHE SHF SHJ SHK SHL SHM SHS SHT SHU SHV SHW SHX Lock chamber gate (upstream) Lock chamber gate (intermediate) Lock chamber gate (downstream) Discharge system (lower pound) Anti-icing system Ship impact system Leakage drainage system Rest evacuation system Minimum water system Fish ladder Wood raft canal Lubricant supply system Sealing fluid supply system Fluid supply system for control and protection equipment Control and protection equipment SHY AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 Project: Document No.: STANDARD LH-DE011017-REV02 Stationary fire protection systems Fire water system, conventional area Spray deluge systems, conventional area Sprinkler systems Foam fire-fighting systems e.g. for oil tank Tank roof, tank shell cooling systems Nitrogen fire-fighting systems e.g. for transformer CO2 fire-fighting systems e.g. for GT Halon fire-fighting systems (FM 200 also InergenSystems) Portable fire extinguisher Fluid supply system for control and protection equipment Alarm and detection system of stationary fire protection system e.g. control panel/cabinet = 01SGY10GH001 Waterway facilities Intake system (upper pound) to excl. lock chamber lock furniture Lock chamber incl. chamber filling and emptying system Lock chamber gate (upstream) Lock chamber gate (intermediate) Lock chamber gate (downstream) Discharge system (lower pound) Anti-icing system Ship impact system Leakage drainage system Rest evacuation system Minimum water system Fish ladder Wood raft canal Lubricant supply system Sealing fluid supply system Fluid supply system for control and protection equipment Alarm and detection system of stationary fire protection system e.g. control panel/cabinet = 01SHY10GH001 C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 88/124 KKS - MASTERLIST SM Cranes, stationary hoists and conveying appliances SMA Cranes, stationary hoists, conveying appliances Cranes, stationary hoists, conveying appliances Cranes, stationary hoists, conveying appliances Cranes, stationary hoists, conveying appliances Cranes, stationary hoists, conveying appliances SMB SMC SMD SMG SMH Cranes, stationary hoists, conveying appliances SMM Cranes, stationary hoists, conveying appliances SMP Cranes, stationary hoists, conveying appliances SN SNA SNB SNC SQ SQA SQB SQC SQD SQE ST Elevators Elevators Elevators Elevators Road installations Road installation Road installation Road installation Road installation Road installation Workshop, stores, laboratory equipment and staff amenities Workshop equipment Maintenance areas Stores and filling station equipment Laboratory equipment Staff amenities Control and protection equipment STA STC STE STG STP STY AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 Project: Document No.: STANDARD LH-DE011017-REV02 Cranes, stationary hoists and conveying appliances; e.g. hoist for transformer of electrostatic-precipitator Cranes, stationary hoists and conveying appliances (free for use e.g. building specific) Cranes, stationary hoists and conveying appliances (free for use e.g. building specific) Cranes, stationary hoists and conveying appliances (free for use e.g. building specific) Cranes, stationary hoists and conveying appliances (free for use e.g. building specific) Cranes, stationary hoists and conveying appliances Water treatment Cranes, stationary hoists and conveying appliances Boiler house Cranes, stationary hoists and conveying appliances Machine hall Cranes, stationary hoists and conveying appliances Cooling water Elevators Elevators (free for use e.g. building specific) Elevators (free for use e.g. building specific) Elevators (free for use e.g. building specific) Road installations Road installations (free for use) Road installations (free for use) Road installations (free for use) Road installations (free for use) Road installations (free for use) Workshop, stores, laboratory equipment and staff amenities outside controlled area Workshop equipment outside controlled area Maintenance areas Stores and filling station equipment Laboratory equipment Staff amenities Control and protection equipment C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 89/124 KKS - MASTERLIST U UA UAA UAB UAC UAD UAE UAF UAG UAH UB UBA UBB UBC UBD UBE UBF UBG UBH UBJ UBK UBL UBM UBN UBP UBQ UC UCA UCB UCC UCD UCE UCF Project: Document No.: STANDARD LH-DE011017-REV02 STRUCTURES STRUCTURES Structures for grid and distribution systems Structures for grid and distribution systems No binding stipulation of F3 subdivision. Those given herein are simply recommendations. Switchyard structure Switchyard structure Grid systems switchgear building Grid systems switchgear building Grid systems control building Grid systems control building Structures for grid and distribution system Structures for grid and distribution systems (free for use) Structure for pneumatic control system Structure for pneumatic control system Structures for grid and distribution system Structures for grid and distribution systems (free for use) Structure for transformer Structure for transformers Structure for supports and equipment Structure for supports and equipment Structures for power transmission and Structures for power transmission and auxiliary power supply auxiliary power supplyNo binding stipulation of F3 subdivision. Those given herein are simply recommendations. Switchgear building Switchgear building Structure for power transmission and auxiliary Structure for power transmission and auxiliary power supply power supply (free for use) Structure for offsite system transformers Structure for offsite system transformers Structure for low-voltage auxiliary power Structure for low-voltage auxiliary power transformers transformers Structure for medium-voltage auxiliary power Structure for medium-voltage auxiliary power transformers transformers Structure for generator transformers Structure for generator transformers Structure for start-up transformers Structure for start-up transformers Structure for oil collecting pits Structure for oil collecting pits Structure for transformer track Structure for transformer tracks Transformer assembly building Transformer assembly building Structure for busbars Structure for busbars Structure for transformer cooling system Structure for transformer cooling systems Structure for emergency power generating set Structure for emergency power generating sets (without central water chiller) Emergency power generating and central water Emergency power generating and central water chiller building chiller building Structure for emergency power generator fuel Structure for emergency power generator fuel supply system supply system Structures for instrumentation and control Structures for instrumentation and control No binding stipulation of F3 subdivision. Those given herein are simply recommendations. Unit control room building Unit control room building Control station building Control station building Structure for control and instrumentation Structure for instrumentation and control (free for use) Structure for control and instrumentation Structure for instrumentation and control (free for use) Structure for control and instrumentation Structure for instrumentation and control (free for use) Structure for control and instrumentation Structure for instrumentation and control (free for use) AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 90/124 KKS - MASTERLIST UG UGA UGD UGE UGF UGG UGH UGK UGL UGN UGP UGQ UGR UGU UGV UL ULN ULP ULQ UM UME UMG UMJ UMM UMR UP UPA UPB UPC UPD UPH UPJ UPN UPP UPQ UPS UPT Project: Document No.: STANDARD LH-DE011017-REV02 Structures for water supply and disposal Structures for water supply and disposal No binding stipulation of F3 subdivision. Those given herein are simply recommendations. Structure for raw water supply Structure for raw water supply Structure for demineralization system Structure for demineralization system Structure for neutralization system Structure for neutralization system Structure for fire water supply Structure for fire water supply Structure for drinking water supply Structure for drinking water supply Structure for rainwater Structure for rainwater Flocculant mixing chamber Flocculant mixing chamber Flocculator structure, flocculator Flocculator structure, flocculator Treated water basin Treated water basin Sludge thickener Sludge thickener Sludge dewatering building Sludge dewatering building Sludge storage structure Sludge storage structure Structure for effluent disposal Structure for effluent disposal Structure for sewerage plant Structure for sewerage plant Structures for steam-, water-, gas-cycles Structures for steam-, water-, gas-cycles No binding stipulation of F3 subdivision. Those given herein are simply recommendations. Structure for hydroelectric power plant water Structure for hydroelectric power plant water impounding works impounding works Structure for hydroelectric power plant intake Structure for hydroelectric power plant intake systems systems Structure for hydroelectric power plant tail-race Structure for hydroelectric power plant tail-race systems systems Structures for main machine sets Structures for main machine sets No binding stipulation of F3 subdivision. Those given herein are simply recommendations. Hydraulic turbine building Hydraulic turbine building Pumped storage turbine building Pumped storage turbine building Diesel engine building Diesel engine building Compressor system building Compressor system building Gas engine plant building Gas engine plant building Structures for circulating (cooling) water Structures for circulating (cooling) water systems systems (e.g. circulating water intake) No binding stipulation of F3 subdivision. Those given herein are simply recommendations. Cooling water intake culvert Cooling water intake culvert Secondary cooling water intake culvert Secondary cooling water intake culvert Cooling water intake structure Cooling water intake structure Secondary cooling water intake structure Secondary cooling water intake structure Structure for cooling water treatment Cooling water treatment structure Structure for secondary cooling water Secondary cooling water treatment structure treatment Cooling water inlet culvert Cooling water inlet culvert Secondary cooling water inlet culvert Secondary cooling water inlet culvert Biocide treatment building Biocide treatment building Debris trough Debris trough Screen wash water cleaning structure Screen wash water cleaning structure AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 91/124 KKS - MASTERLIST UQ UQA UQB UQG UQH UQJ UQK UQL UQM UQN UQP UQQ UQR UQS UQT UQU UQV UQW UR URA URB URC URD URE URF URG URH URJ URK URL URM URN URP URQ Project: Document No.: STANDARD LH-DE011017-REV02 Structures for circulating (cooling) water systems Structures for circulating (cooling) water systems (e.g. circulating water pumps and outfall) No binding stipulation of F3 subdivision. Those given herein are simply recommendations. Cooling water pump building Cooling water pump building Secondary cooling water pump building Secondary cooling water pump building Cooling water overflow structure, surge tank Cooling water overflow structure, surge tank Screen wash water discharge culvert Screen wash water discharge culvert Cooling water seal pit Cooling water seal pit, incl. cooling water aeration structure Cooling water venting structure Cooling water venting structure Secondary cooling water surge pond Secondary cooling water surge pond Secondary cooling water collecting pond Secondary cooling water collecting pond Cooling water outfall culvert Cooling water outfall culvert Secondary cooling water outfall culvert Secondary cooling water outfall culvert Cooling water outfall structure Cooling water outfall structure Secondary cooling water outfall structure Secondary cooling water outfall structure Cooling water discharge culvert Cooling water discharge culvert Secondary cooling water discharge culvert Secondary cooling water discharge culvert Cooling water spillway structure Cooling water spillway structure, incl. cooling water aeration structure Structure for artificial cooling water aeration Structure for artificial cooling water aeration Routing structure for cooling water discharge Routing structure for cooling water discharge Structures for circulating (cooling) water Structures for circulating (cooling) water systems systems (e.g. recirculation cooling) No binding stipulation of F3 subdivision. Those given herein are simply recommendations. Cooling tower structure Cooling tower structure (main cooling water) Cooling tower structure Cooling tower structure (secondary cooling water) Structure for cooling water system (secondary Structure for cooling water systems (e.g. cooling water) recirculation cooling) (free for use) Cooling tower pump building Cooling tower pump building (main cooling water) Cooling tower pump building (secondary Cooling tower pump building (secondary cooling cooling water) water) Structure for cooling water system Structure for cooling water systems (e.g. recirculation cooling) (free for use) Cooling tower connecting structure Cooling tower connecting structure Cooling tower outlet structure Cooling tower outlet structure Cooling tower outfall culvert Cooling tower outfall culvert Cooling tower return structure Cooling tower return structure Cooling tower return culvert Cooling tower return culvert Cooling water distribution building Circulating (cooling) water distribution building Cooling tower bypass structure Cooling tower bypass structure Cooling tower blowdown structure Cooling tower blowdown structure Cooling tower blowdown culvert Cooling tower blowdown culvert AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 92/124 KKS - MASTERLIST US USA USB USC USG USH UST USU USV USX UT UTF UY UYA UYB UYC UYD UYE UYF UYG UYH UYJ UYP UYQ UYR UYS UZ UZA UZC UZD UZE UZF UZJ UZK UZL UZM UZN UZP UZQ UZR UZS UZT UZU UZW UZX UZY UZZ Project: Document No.: STANDARD LH-DE011017-REV02 Structures for ancillary systems Structures for ancillary systems No binding stipulation of F3 subdivision. Those given herein are simply recommendations. Structure for heating, ventilation, airStructure for heating, ventilation, air-conditioning conditioning (HVAC) systems (HVAC) systems Structure for space heating systems Structure for space heating systems Structure for stationary compressed air supply Structure for stationary compressed air supply system system Fire pump house Fire pump house Structure for waterway facilities Structure for waterway facilities Workshop Workshop Storage building Storage building Laboratory building Laboratory building Special structure (plant-specific) Oil/water separators incl. Drainage Structures for auxiliary systems Structures for auxiliary systems No binding stipulation of F3 subdivision. Those given herein are simply recommendations. Compressed air system building Compressed air system building General service structures General service structures (These F3 subdivisions are binding.) Office and staff amenities building Office and staff amenities building Staff amenities building Staff amenities building Administration building Administration building Canteen Canteen Gate house Gate house Security gate house Security gate house Information centre Information centre Training facilities Training facilities Medical centre Medical centre Structure for fire station Fire station Garage Garage Automobile workshop Automobile workshop Filling station Filling station Structures for transport, traffic, fencing, Structures for transport, traffic, fencing, gardens and other purposes gardens and other purposes These F3 subdivisions are binding. Roads Works roadways, paths, incl. associated structures Yards Yards Parking areas, incl. associated structures Parking areas, incl. associated structures Railway structures Railway structures Lifting gear structures Lifting gear structures Fencing and gates Fencing and gates Gardens, incl. structures Gardens, incl. structures Noise abatement structures Noise abatement structures Protective structures against external impact Protective structures against external impact Structure for flood protection Structure for flood protection Structure for bank/shoreline stabilization Structure for bank/shoreline stabilization Structure for river regulation Structure for river regulation Jetty, quay Jetty, quay Breakwaters Breakwaters Outdoor area, plots of land and land rights Outdoor area, plots of land and land rights Site security structure Site security structure Residential buildings, residential area Residential buildings, residential area Special structure (plant-specific) Special structure (plant-specific) Bridge structure Bridge structure Ducting structure Storm water drainage system AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 93/124 KKS - MASTERLIST W WA Project: Document No.: STANDARD LH-DE011017-REV02 RENEWABLE ENERGY PLANTS RENEWABLE ENERGY PLANTS Solar systems (free for use for coordinates) Solar systems (free for use for coordinates) AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 94/124 KKS - MASTERLIST X HEAVY MACHINERY XE XEA Hydraulic turbine plant Turbine (casing, shaft, runner etc.) XEB Isolating valve XED XEG Bearings Stabilizing air system XEK Gear XEL XES XEV Water depression air supply system Shaft gland cooling water system Lubricant supply system XEW Sealing water supply system XEX Hydraulic oil XEY XG XGA XGB Protection Pumped-storage plant Storage pump (casing, shaft, runner etc.) Isolating valve XGD XGK Bearings Gear XGL XGM XGS XGV Water depression air supply system Start-up unit Shaft gland cooling water system Lubricant oil supply XGW XGX Sealing fluid system Control oil XGY Control and protection equipment AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 Project: Document No.: STANDARD LH-DE011017-REV02 HEAVY MACHINERY Hydraulic turbine plant Turbine from excl. turbine inlet or from excl. inlet valve to incl. turbine outlet or to excl. isolating valve, incl. draft tube blocking headwater before turbine XEA and/or setting headwater for turbine XEA Bearings Stabilizing air system from incl. air compressor to incl. outlet to turbine Transmission gear between prime mover and driven machine, incl. turning gear, barring gear from incl. air compressor to incl. outlet to turbine Shaft gland cooling water system from incl. lubricant tank to excl. user and from excl. user from incl. sealing water supply main isolating valve to excl. casing nozzle of sealing water user Non-electric control and protection equipment, incl. fluid supply system Electrical control and protection equipment Pumped-storage plant Storage pump (casing, shaft, runner etc.) blocking water before storage pump XGA and/or setting water for storage pump XGA Bearings Transmission gear between motor generator set and storage pump from incl. air compressor to incl. outlet to pump Start-up unit Shaft gland cooling water system Lubricant supply system from incl. dedicated lubricant tank or coon lubricant and control fluid tank or from excl. branch off control fluid supply system to excl. user from excl. user Sealing fluid supply system Fluid supply system for control and protection equipment Control and protection equipment. Only for mechanical equipment (pneumatic or hydraulic) C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 95/124 KKS - MASTERLIST XJ XJA Diesel engine plant Engine XJB Turbocharger, blower XJG Liquid cooling system XJH Air intercooling system XJK Gear XJN Fuel system XJP XJQ Start-up unit Air intake system XJR Exhaust gas system XJV Lubricant supply system XJW XJX Sealing fluid supply system Fluid supply system for control and protection equipment Control and protection equipment XJY AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 Project: Document No.: STANDARD LH-DE011017-REV02 Diesel engine plant Engine from incl. fuel injection nozzle inlet or from incl. air intake nozzles or from incl. cooling water inlet nozzles to incl. exhaust nozzle outlet or to incl. cooling water nozzle outlet, incl. engineinternal systems Turbocharger, blower from incl. turbocharger or blower inlet to incl. turbocharger or blower outlet Liquid cooling system from excl. engine cooling water nozzle outlet or from incl. turbocharger air cooling system inlet to excl. engine cooling water nozzle inlet or to incl. turbocharger air cooler outlet Air intercooling system from incl. intercooler inlet to incl. intercooler outlet to excl. outlet to other cooling systems Transmission gear between prime mover and driven machine Fuel systems from incl. temporary (day) tank or from excl. branch off piping system to excl. fuel injection nozzle inlet Start-up unit, (incl. flywheel) Air intake system from excl. atmosphere to excl. turbocharger or to excl. engine air intake nozzles Exhaust gas system from excl. engine exhaust nozzle outlet to excl. discharge to atmosphere Lubricant supply system from incl. dedicated lubricant tank or coon lubricant and control fluid tank or from excl. branch off control fluid supply system to excl. user from excl. user Sealing fluid supply system Fluid supply system for control and protection equipment Control and protection equipment C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 96/124 KKS - MASTERLIST XK XKA Generator plant Generator, complete, incl. stator, rotor and all integral cooling equipment XKB Excitation XKC Excitation XKD Bearings Bearing pedestal Thrust bearing XKF Stator/rotor cooling system XKG Stator/rotor cooling system XKH Stator/rotor cooling system XKJ Stator/rotor cooling system XKQ Exhaust gas system XKU Stator/rotor cooling system XKV Lubricant supply system XKW Sealing fluid supply system XKX Fluid supply system for control and protection equipment Control and protection equipment XKY AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 Project: Document No.: STANDARD LH-DE011017-REV02 Generator plant Generator, complete, incl. stator, rotor and all integral cooling equipment to incl. generator bushing Generator exciter set (use only if *XKC* is not sufficient for identification) Generator exciter set, even with electric generator brake Bearings Standard application is: XKD10 = bearing pedestal driven end (DE) XKD20 = bearing pedestal excitation end (EE) Stator/rotor liquid cooling system, incl. coolant supply system (Note: for cooling oil see *XKU*) Task: dissipate heat produced by stator/rotor to coolant, from excl. stator/rotor outlet to excl. stator/rotor inlet Stator/rotor hydrogen cooling system, incl. coolant supply system Task: dissipate heat produced by stator/rotor to coolant, from excl. stator/rotor outlet to excl. stator/rotor inlet Stator/rotor nitrogen / carbon dioxide cooling system, incl. coolant supply system Task: dissipate heat produced by stator/rotor to coolant, from excl. stator/rotor outlet to excl. stator/rotor inlet Stator/rotor air cooling system, incl. coolant supply system Task: dissipate heat produced by stator/rotor to coolant from excl. stator/rotor outlet to excl. stator/rotor inlet Exhaust gas system (if separate from *XKG* and *XKH*) Stator/rotor cooling oil cooling system, incl. coolant supply system (Note: for other liquid cooling see *XKF*) Task: dissipate heat produced by stator/rotor to coolant from excl. stator/rotor outlet to excl. stator/rotor inlet Lubricant supply system (if separate system for generator) Sealing fluid supply system (Sealing oil system, incl. supply and treatment) from excl. branch off sealing oil supply system to excl. stator inlet and from excl. stator outlet to excl. inlet to other system or in closed systems from excl. stator outlet Fluid supply system for control and protection equipment Control and protection equipment C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 97/124 KKS - MASTERLIST XP XPA XPB XPG XPR XPS Common installations for heavy machinery Foundation Casing Frame, support structure Forced cooling system Drying and conservation system AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 Project: Document No.: STANDARD LH-DE011017-REV02 Common installations for heavy machinery Foundation Casing, Cover Frame, support structure Forced cooling system Drying and conservation system C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 98/124 KKS - MASTERLIST Z WORKSHOP AND OFFICE EQUIPMENT ZC Workshop and office equipment (free for use) AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 Project: Document No.: STANDARD LH-DE011017-REV02 WORKSHOP AND OFFICE EQUIPMENT Workshop and office equipment (free for use) C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 99/124 Project: Document No.: KKS - MASTERLIST STANDARD LH-DE011017-REV02 Equipment Unit Key (Breakdown level 2) A Mechanical equipment (Unit) AA Valve (Fitting) Valve Gate valve Globe valve Flap (Damper) Condensate trap Rupture disc Control valve Reducing valve Control flap (damper) Bleeder control valve Bypass control valve Bypass control flap (damper) Reducing station Butterfly control valve Shut-off valve Shut-off valve Gate valve Stopcock (Globe valve) Shut-off flap (damper) Shut-off equipment Bleeder Shut-off valve Drain valve Valve Flap (Damper) Safety valve Safety flap (damper) Rupture disc Test valve Shut-off valve Stopcock Valve Flap (Damper) Gate valve Stopcock (Globe valve) 3-Way cock 3-Way valve Drainage valve Drainage valve Vent valve AA001 AA101 AA201 AA301 AA401 AA501 AA601 AA701 AA801 AA901 Check valve Non-return valve Condensat trap Mechanical equipment Valves, dampers, etc., incl. actuators, also manual; rupture disc equipment Counting-No 100-position : 0, starts with 001 The 2nd position of the counting No indicates the kind of actuation: 001 up to 049 with remote actuator 051 up to 099 with manual actuator or with process-media Counting-No 100-position : 0, starts with 101 Generally all Shut-off valves with remote actuator Open/Close-Valves with actuators (electr. pneum., hydr.), solenoid valves (even pilot valves). 151 up to 199 only for vent/drain purpose Counting-No 100-position : 0, starts with 201 Valves specially for steam turbine control Counting-No 100-position : 0, starts with 301 Generally all safety valves (spring-, weight-, or aux. media supported) Counting-No 100-position : 0, starts with 401 Only for testing or acceptance test (not for operational measurements!) Counting-No 100-position : 0, starts with 501 Manually actuated process shut-off valves, even for dosing valves to process branches. Counting-No 100-position : 0, starts with 601 Generally only for manually actuated shut-off valves, valves with remote actuator see *AA101*) Counting-No 100-position : 0, starts with 701 Counting-No 100-position : 0, starts with 801 Condensate trap Counting-No 100-position : 0, starts with 901 Isolating valves for operational measurements, e.g. for: pressure-, differential pressure-, level-, flow-, and even for tappings of analysing measurements Isolating valve Shut-off valve Stopcock AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 100/124 KKS - MASTERLIST AB AC Lock (sluice, gate) Heat exchangers AE Turning gear Driving gear Lifting gear Slewing gear Feeder Cell wheel Conveyor Belt conveyor Generator Heater Cooler Air conditioning unit Crusher Mill Compacting equipment AF AG AH AJ AK AM AN AP AS AT AU AV AX Agitator Mixer Worm (Screw) Compressor Compressor unit Blower Fan Pump Speed adjusting unit Filter Soot blower Dryer Brake Gearbox Coupling Burner Igniter Ignition burner Test and monitoring equipment AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 Project: Document No.: STANDARD LH-DE011017-REV02 Isolating elements, air locks Heat exchangers, heat transfer surfaces. Only for media/media (not for electrical heaters, see *AH*). Turning, driving, lifting and slewing gear (also manipulators) Continuous conveyors, feeders (escalators) Note: mixer/agitators see *AM* Generator units Heating, cooling and air conditioning units Size reduction equipment, only as part of process Compacting and packaging equipment, only as part of process Mixers, agitators Note: conveyors see *AF*; if both, then *AM* Compressor units, fans Pump units Adjusting and tension equipment for nonelectric variables Cleaning, drying, filtering and separating equipment, excl. *BT* Braking, gearbox, coupling equipment, nonelectrical converters Combustion equipment Test and monitoring equipment for plant maintenance C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 101/124 KKS - MASTERLIST B Mechanical equipment (Apparatus) BB Tank Vessel Container basin (pit) Shafts Foundation Jet pump Injector Ejector (Nozzle) Flow restrictor Throttle (Throttle orifice) Hangers Supports Racks Piping penetrations Pipeline Pipe Chute Silencer Flue gas catalytic converter module Insulation, sheathing Enclosure (off base enclosure) BE BF BN BP BQ BR BS BT BU AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 Project: Document No.: STANDARD LH-DE011017-REV02 Apparatus Storage equipment (tanks) Shafts (for erection and maintenance only) Foundations Jet pumps, ejectors, injectors, Nozzles for distinguishing systems Flow restrictor, limiters, orifices (not metering orifices) Hangers, supports, racks, piping penetrations Piping, ductwork, chutes Silencers Flue gas catalytic converter modules Insulation, sheathing (please do not use) C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 102/124 KKS - MASTERLIST C Direct measuring circuits CB Radiation values CD CE Density Current Voltage Power Frequency Resistance Impedance Current Voltage Power CE001 CE100 Current Measuring CE111 Current Phase L1 CE111A Current L1 transformer core 1 CE111B Current L1 transformer core 2 CE111C Current L1 transformer core 3 CE112 Current Phase L2 CE112A Current L2 transformer core 1 CE112B Current L2 transformer core 2 CE112C Current L2 transformer core 3 CE113 Current Phase L3 CE113A Current L3 transformer core 1 CE113B Current L3 transformer core 2 CE113C Current L3 transformer core 3 AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 Project: Document No.: STANDARD LH-DE011017-REV02 Direct measuring circuits (Data char. A2 following DIN 19227, part 1, Sept. 1973 edit., tab.1, init. letter) Take care of counting system, valid is: analog =001 ff binary = 301 ff testing =401 ff local = 501 ff virtual =901 ff Deviations as indicated in VGB blocked (please do not use, use instead of *CR* and *CQ* if possible) Density measurements Electrical variables (e.g. current, voltage, power, electr. Frequency) Note different kind of counting to process relevant measurement variables! Counting No. 100-position: 0=electrical analog measuring value, only for aggregates e.g. current governor oil-pump motor counting no.1-position: starts with 001 Counting No. 100-position: 1=current analog measuring value Counting No. 1-position: 1=current phase L1 analog measuring value Counting No. 1-position: 1=current phase L1 transformer core 1 analog measuring CH A Counting No. 1-position: 1=current phase L1 transformer core 2 analog measuring CH B Counting No. 1-position: 1=current phase L1 transformer core 3 analog measuring CH C Counting No. 1-position: 2=current phase L2 analog measuring value Counting No. 1-position: 2=current phase L2 transformer core 1 analog measuring CH A Counting No. 1-position: 2=current phase L2 transformer core 2 analog measuring CH B Counting No. 1-position: 2=current phase L2 transformer core 3 analog measuring CH C Counting No. 1-position: 3=current phase L3 analog measuring value Counting No. 1-position: 3=current phase L3 transformer core 1 analog measuring CH A Counting No. 1-position: 3=current phase L3 transformer core 2 analog measuring CH B Counting No. 1-position: 3=current phase L3 transformer core 3 analog measuring CH C C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 103/124 KKS - MASTERLIST CE200 Voltage measuring CE210 CE211 Voltage star point Voltage L1 Phase CE212 Voltage L2 Phase CE213 Voltage L3 Phase CE214 Voltage L1-L2 phase to phase CE215 Voltage L2-L3 phase to phase CE216 Voltage L3-L1 phase to phase CE300 Power Resistance Impedance Frequency CE500 CE600 Earth fault (Ground fault) Phase failure CE900 combined, calculated measuring circuits CF Flow Measurement CG Position Distance Length Direction of rotation CG301 Position opened CG301A Position opened CG301B Position closed CG302 Position closed CH Hand actuated Manual CK Time AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 Project: Document No.: STANDARD LH-DE011017-REV02 Counting No. 100-position: 2=voltage analog measuring value Counting No. 1-position: 0=voltage starpoint Counting No. 1-position: 1=voltage phase L1 analog measuring value Counting No. 1-position: 2=voltage phase L2 analog measuring value Counting No. 1-position: 3=voltage phase L3 analog measuring value Counting No. 1-position: 4=voltage phase L1 to phase L2 analog measuring value Counting No. 1-position: 5=voltage phase L2 to phase L3 analog measuring value Counting No. 1-position: 6=voltage phase L3 to phase L1 analog measuring value Counting No. 100-position: 3=power analog measuring value Counting No. 100-position: 5=frequency analog measuring value Counting No. 100-position: 6=special measurement e.g. earth fault, phase failure Counting No. 100-position: 9=combined, calculated measuring circuits Orifice plate and diff.-pressure transmitter, inductive mass flow, ultrasonic mass flow, oil counters, flow switches Position transmitter, limit switch (Pls note: for easier coordination, the counting No. of the position X´ter can be identical to the valve counting No., take care of deviation to the existing counting rule for measurements) e.g. limit switch: valve OPEN Note: alternative see *CG301A* e.g. Limit switch valve: OPEN Note: alternative to *CG301*, here better coordination with the valve-No.! e.g. Limit switch valve: CLOSE Note: alternative to *CG302*, here better coordination with the valve-No.! e.g. limit switch: valve CLOSE Note: alternative see *CG301B* Manual input as manually operated sensor (e.g. fire detector, emergency stop wire for belt conveyors, escape route push button. Skewing switch for belt conveyors see *CY*) Time e.g. external clock to DCS, PLC etc. C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 104/124 KKS - MASTERLIST CL CM Level Dividing line Moisture measurement CP Pressure measurement Diff. pressure measurement CQ Analysis Quality variable Conductivity PH-value O2-content SiO2-content NH3-content Analysis Radiation variable UV-Radiation Infra red radiation Fire Flame intensity Revolution (Speed) Frequency Speed, Velocity Acceleration Temperature measuring Diff. temperature measurement CQ801 CR CS CT CT001A Temperature measuring circuit 1 of 2 CT001B Temperature measuring circuit 2 of 2 CT601 CT801 CU CV CW CY Metal temperature (white metal) Wall temperature (drum-, superheater-) Temperature Dewpoint Heat quantity and others variables Viscosity Weight Mass Vibration Expansion AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 Project: Document No.: STANDARD LH-DE011017-REV02 Level (also for dividing line) e.g. air humidity measurement in air cooler system of generator Pressure X´ter, diff. pressure X´ter, pressure switch, pressure gauge, pressure gauge with contact Quality variables (analysis, material properties), other than *CD*, *CM*, *CV* Counting No. 100-position: 8=gas detection Radiation variable e.g. flame scanner with UV-sensor (analog or binary output) Velocity, speed, frequency (mechanical), acceleration Thermometer, remote thermometer (RTD, TC) with and w/o T-X´ter, contact thermometer, thermostat & temperature switch first temperature measuring circuit from a double-element (double TC or RTD) second temperature measuring circuit from a double-element (double TC or RTD) White-metal-temperature Wall-temperature (drum-, superheater-) Counting No. 100-position: 8=fire detection Combined and other variables (ie. Dewpoint) Viscosity Weight, mass; measurement with weighing device/load cell e.g. weighing measurement for CO2 bottles e.g. turbine shaft vibration, shaft expansion (relative or absolute), skewing switch for belt conveyors. C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 105/124 KKS - MASTERLIST D Closed loop control circuits DD DE Density Voltage control DF Flow control DG DK DL Position control Time control Level control DM DP Moisture, humidity Pressure control DQ DR DS Conductivity control PH-Control O2-Control NOx-Control Radiation Speed (revolution) control DT Temperature control DU DV Combined and other variables Viscosity control DW DY Weight force control Vibration control Expansion control AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 Project: Document No.: STANDARD LH-DE011017-REV02 Closed loop control circuit (Data char. A2 following DIN 19227, part 1, Sept. 1973 edit., tab.1, init. letter) Only for complete loop in loop diagram; not for use in P&I-diagrams! Counting system see (C) Density Electrical values (e.g. voltage, current, power, frequency) e.g. 01BBA01DE001 voltage control Flow, mass flow e.g. 01PAC10DF001 maincoolingwater flow control Distance, length, position, direction of rotation Time Level (also for dividing line) e.g. 01MEX10DL001 Governor oil level control Moisture, humidity Pressure e.g. 01MEX10DP001 governor oil pressure control Quality variables (analysis, material properties), other than *DD*, *DM*, *DV* Radiation variables Velocity, speed, frequency (mechanical), acceleration Temperature e.g. 01MEX10DT001 governor oil temperature control Combined and other variables Viscosity e.g. 00MEX01DV001 oil viscosity control Weight, mass Vibration, expansion C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 106/124 KKS - MASTERLIST E Analog and binary signal conditioning EA Basic open loop control EB Functional-/Group control EC Sub functional group ED EE EG EJ EK EM Sub functional group Sub loop control Alarms Annunciations Alarms Annunciations Report printer Logic Process computer EN EP EQ EU Process computer Process computer Process computer Logic EW EX EX001 EX002 EY EZ EZ041 EZ042 EZ043 EZ044 EZ045 EZ046 EZ047 EZ050 EZ051 EZ052 EZ053 EZ054 EZ055 EZ056 Protection Protection Protection release 1 Protection release 2 Protection Protection Auxiliary voltage disturbed/missing Fault MCB Fault fuse Fault distributor Fault breaker Fault rectifier Fault battery Fault common protective relay Fault overcurrent relay Fault overvoltage relay Fault earth leakage relay Fault switchgear Fault auxiliary voltage Fault frequency converter common EH AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 Project: Document No.: STANDARD LH-DE011017-REV02 Measurement-, Signal conditioning (conditioning e.g. in DCS, hand over to other systems, e.g. from DCS to steam turbine control system or reverse) Note: only for logics conditioned in systems, do not mistake with *C_* ! Basic open loop control (basic operation/control from a power plant, e.g. load control and start-up/stop sequences) Functional-/Group control e.g. start-up/stop sequences of plant sections (ST, GT, HRSG) Sub functional-/group control e.g. change-over automatic for 2x100% pump drives Sub functional-/group control like as *EC* Sub loop control Annunciation logic Annunciation conventional Report printer Combined logic Special computer (e.g. for personnel access control) Criteria computer Process computer Process computer Combined measurement value-, signal conditioning, e.g. 2/3-selection or signal average of grid measurements Protection Protection Protection Protection Protection Protection Alarm electric Alarm electric Alarm electric Alarm electric Alarm electric Alarm electric Alarm electric Alarm electric Alarm electric Alarm electric Alarm electric Alarm electric Alarm electric Alarm electric C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 107/124 KKS - MASTERLIST F Indirect measuring circuits FD FE Density Electrical variable FF Flow, rate FG FK FL Length Time Level FM FP FQ Moisture, humidity Pressure Analysis FS Revolution FT FU FV FW Temperature Dewpoint Viscosity Weight Mass FY Vibration Expansion AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 Project: Document No.: STANDARD LH-DE011017-REV02 Indirect measuring circuits (Data character A2 following DIN 19227, part 1, Sept. 1993 edit., table 1, initial letter) Note: these circuits will be calculated from different physically direct measurements Density Electrical variables (e.g. electr. efficiency, power) Flow, rate e.g. Flow measurement with P- & T-correction. 01MEX10CF001, 01MEX10CP001, 01MEX10CT001 = 01MEX10FF001 or 901. Note: counting No. is 901 if calculated in DCS, respective 001 if calculated local with CorrX´ter. Distance, length, position, direction of rotation Time Level (also for dividing line) e.g. level measurement with P-correction 01MEX10CL001, 01MEX10CP001 = 01MEX10FL001 or 901 Moisture, humidity Pressure Quality variables (analysis, material properties), other than *FD*, *FM*, *FV* Velocity, speed, frequency (mechanical), acceleration Temperature Combined and other variables Viscosity Weight, mass; measurement with weighing device/load cell e.g. weighing measurement for CO2 bottles Vibration, expansion C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 108/124 KKS - MASTERLIST G GA GB GC GD GE GF GG GH GJ GK GK101 GK201 GK301 GK401 GK501 GK701 GK801 GM GN GP Project: Document No.: STANDARD LH-DE011017-REV02 Electrical, Instrumentation and Control equipment Cabinets, Junction boxes, Penetrations Junction boxes/penetrations for binary sensors Junction boxes and cable/bus bar penetrations for binary sensors (free for use) Junction boxes/penetrations for binary sensors Junction boxes and cable/bus bar penetrations for binary sensors (free for use) Junction boxes/penetrations for analog sensors Junction boxes and cable/bus bar penetrations for analog sensors (free for use) Junction boxes/penetrations for power cables Junction boxes and cable/bus bar penetrations > 1 kV for power cables > 1 kV Junction boxes/penetrations for power cables Junction boxes and cable/bus penetrations < 1 < 1 kV kV e.g. JB on aggregate from subsupplier, process relevant/technological identification 01MEX10GE001 = JB electrical heaters GOP1 Junction boxes/penetrations for C&I-cables Junction boxes for C&I-equipment e.g. JB on aggregate from subsupplier, process relevant/technological identification 01MEX10GF001 = JB bearing temp. GOP1 Junction boxes and cable/bus bar penetrations Junction boxes and cable/bus bar penetrations (free for use) Switch board (Control cabinet) Electrical and instrumentation and control Switch box (Control box) installation units identified as per process Panel (Control panel) system (e.g. cubicles, boxes) Cabinet e.g. local control cabinet for hydraulic system of coal bunkers Processing and storage equipment for automatic Processing and storage equipment for systems automatic systems Information Information display and operator control Operation equipment for process computers and automation systems e.g. monitors, keyboards, printers for the DCS Note: counting system as follows Monitor Counting No. 100-position: 1 Screen Keyboard Counting No. 100-position: 2 Mouse Counting No. 100-position: 3 Trackball Light pen CD-Rom drive Counting No. 100-position: 4 Streamer Counting No. 100-position: 5 Printer Counting No. 100-position: 7 Copy machine Disc drive, Floppy disc station Counting No. 100-position: 8 Subdistribution/junction box for telephone Junction boxes for light-current systems of national telecommunication services (nonnational see *GY*) Network equipment Network equipment Subdistribution/junction box for lighting Subdistribution/junction boxes for lighting e.g. 01UMJ00GP100 = distribution board diesel engine house UMJ Electrical, Instrumentation and Control equipment AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 109/124 KKS - MASTERLIST GQ Subdistribution/junction box for Power sockets GR DC generating equipment, battery GS Switch Switch gear equipment Switch gear truck Motor control centre Cabinet partition Motor control centre (MCC/PDC) GS001 GS100 Circuit breaker GS101 GS110 Switch gear truck Disconnector 1 GS120 Disconnector 2 GS190 Cable disconnector GS191 Earthing disconnector GT Transformer GU Converter GV Surge arrestor GW Power supply GX Frequency converter GY Junction boxes for light-current systems (not of national telecommunication services) GZ Transmitter rack AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 Project: Document No.: STANDARD LH-DE011017-REV02 Subdistribution/junction boxes for sockets e.g. 01UMJ11GQ051 = first UPS-power socket board on elevation 11m in diesel engine house DC generating equipment, batteries if as an external, stationary equipment Switchgear equipment if not identified under process equipment (see then *GH*) Note: it is possible to give each partition/cabinet one separate No, or (for smaller units) the complete unit one No. Counting No. 100-position: 1, first No. 0 Circuit breaker Counting No. 100-position: 1, first No. 1 Counting No. 100-position: 1, second No. 1 Disconnector 1 Counting No. 100-position: 1, second No. 2 Disconnector 2 Counting No. 100-position: 1, second No. 9 Cable disconnector Counting No. 100-position: 1, second No. 9, first No. 1 Earthing disconnector Transformer equipment if as an external, stationary equipment Note: normally, the internal cabinet equipment will be identified with *-_*, in that case with *T01* Converter equipment e.g. DC/DC-converter and battery power supply if as an external, stationary equipment Note: normally, the internal cabinet equipment will be identified with *-_*, in that case with *U01* Structure-related earthing and lightning protection equipment, surge arrestors Cabinet power supply equipment if as an external, stationary equipment Note: normally, the internal cabinet equipment will be identified with *-_*, in that case with *U01* Actuating equipment for electrical variables e.g. frequency converter if as an external, stationary equipment Note: normally, the internal cabinet equipment will be identified with *-_*, in that case with *U01* Junction boxes for light-current systems (not of national telecommunication services) e.g. Intercom Hangers, supports and racks for electrical, instrumentation and control equipment e.g. 01UMJ17GZ001 (first rack on elevation 17m in diesel engine house UMJ) C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 110/124 KKS - MASTERLIST H Subassemblies of main and heavy machinery HA HB HD Casing, housing Rotor Bearing Bearing pedestal Axial bearing Thrust bearing AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 Project: Document No.: STANDARD LH-DE011017-REV02 Subassemblies of main and heavy machinery (only to be used in conjunction with *M* = Main machine sets and *X* = Heavy machinery) Machine stationary assembly Machine rotating assembly Bearing assembly C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 111/124 Project: Document No.: KKS - MASTERLIST STANDARD LH-DE011017-REV02 Component Key (Breakdown level 3) - Electrotechnical Components -A Subassembly (Module) Subrack (Mounting rack/rail) Plug-in module/card Plug-in module/card/rack Printed circuit board/module Unit/device combination Strain gage Density probe Speed sensor Transmitter (Transducer) Pressure transmitter Mass transducer Flow transmitter Level transmitter Temperature sensor Thermocouple (TC) Resistance therm. (RTD) Vibration sensor Loudspeaker I/P-Positioner Capacitor Binary element Recorder tape Recorder tape memory Memory Memory Memory device Logic device Timer Delay device Lighting Electrical fence Heating Trace heating Infeeding -B -C -D -E -F -G Shutter release, trigger Bimetal Buchholz protector/relay Centrifugal switch Fuse Expulsion fuse Surge arrester Battery Generator Power supply unit Static converter Electrical power supply AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 Electrotechnical Components Assemblies and subassemblies Transducers for non-electrical to electrical variable and vica-versa Note: for electrical to electrical see *-U* Capacitors Binary element, delay devices, memory devices Special components but also for cabinet infeedings Note: a differentiation with the counting-No. is useful, dependent from kind of infeeding, e.g.: 01,02,03 main infeedings 21,22 control voltage DC 51,52 UPS Protective devices Generators, power supplies C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 112/124 Project: Document No.: KKS - MASTERLIST -H -K -L -M -N -P -Q -R -S Drop indicator Annunciation unit Annunciator Bell Horn Illuminated indicator Detector/Indicator/Annunciator Signal lamp (pilot lamp) Flasher relay Main contactor Contactor relay Auxiliary relay Power contactor Relay Contactor Inductor Choke coil Wave lock Motor (also actuator) High voltage motor Low voltage motor Controller Master controller Cascade controller Master controller Positioner Amplifier Impedance transformer Video display terminal (VDT) Visual display unit (VDU) Pulse counter Measuring instrument Oscilloscope Testing equipment Simulator Clock Counter Installation switch Load disconnector (isolator) Circuit breaker Motor protection switch Disconnecting switch Disconnector (isolator) Starter Potentiometer Shunt Resistor Pushbutton Limit switch Illuminated pushbutton Acknowledgement switch Pushbutton Selector switch AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 STANDARD LH-DE011017-REV02 Signalling device Relays, contactors Inductor E-Motors Amplifiers, controllers Measuring instruments, testing equipment Power switchgear Resistors Switches, selectors C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 113/124 Project: Document No.: KKS - MASTERLIST -T -U -V -W -X -Y -Z Potential transformer Current transformer Transformer Isolation transformer Analog-digital converter Digital-analog converter Demodulator Telecontrol unit Frequency converter Direct current transducer Modulator Optocoupler Temperature transmitter Converter Isolating amplifier I/I-Positioner Nixi-tube Diode Rectifier Tube (cathode-ray) Zener diode Aerial Cable Coaxial-cable Optical fibre, Optical waveguide Busbar Jack Terminal Terminal strip Crossbar distributor Coaxial connector/jack Solder tag strip Test jack Plug Socket Brake Brake fan Clutch, coupling Magnetic valve Motor potentiometer Control drive (solenoid, coil) Limiter Equalizer Filter RC-Filter Cross over network Cable termination AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 STANDARD LH-DE011017-REV02 Transformers Modulators, converters from electrical to other electrical variables Tubes, semiconductors Transmission path, waveguides, aerials Terminals, plugs, sockets Electrical positioners, e.g. Solenoids (not motors) Termination, balancing equipment, filters, limiters, cable terminations, equalizers, hybrid transformers C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 114/124 KKS - MASTERLIST Project: Document No.: STANDARD LH-DE011017-REV02 K Mechanical components Mechanical components KA Gate valve Valve (Globe valve) Flap (Damper) Cock Bursting disc Throttle plate Manifold Blank (Figure-eight blank) Gate Door Dam board Heat exchangers Cooler Vessel, tank Basin (pit) Surge tank Turning gear Driving gear Lifting gear Slewing gear Belt conveyor Conveyor Screw conveyor Conveying line Feeder Size reduction machines Compacting equipment Packaging machine Mixers Agitators Compressor Blower Fan Pump Cleaning machine Soot blower Dryer Separator Filter Burner Firing grate Grate Ash grate Stationary tooling and treatment machines for maintenance Gate valves, globe valves, dampers, cocks, rupture disks, orifices (typical: manifold for dP-X´ter) KB KC KD KE KF KJ KK KM KN KP KT KV KW AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 Gates, doors, dam boards Heat exchangers, coolers Vessel,basin (pit), surge tank (fluid systems) Turning, driving, lifting and slewing gear Continuous conveyors, feeders Size reduction machines Compacting, packaging machine Mixers, agitators Compressors, blowers, fans Pump Cleaning machines, dryers, separators, filters Burners, grates Stationary tooling and treatment machines for maintenance C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 115/124 KKS - MASTERLIST M Mechanical components MB MF MG MK MM MR Brake Foundation Gearbox Clutch, coupling Engine, not electrical Pipe Chute Positioner Turbine Transmission gear Booster MS MT MU AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 Project: Document No.: STANDARD LH-DE011017-REV02 Mechanical components Brakes Foundations Gearboxes Clutches, couplings Engines, not electrical Piping components, ductwork components Positioners, not electrical Turbines Transmission gear, non electrical, converters and boosters other than couplings and gearboxes C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 116/124 Project: Document No.: KKS - MASTERLIST Q Instrumentation and control components QB Sensor QH Signalling device Annunciation device/unit Controller Flybolt governor Measuring instrument Testing equipment Measurement piping QN QP QR QS QT QU Expansion tank Condensate pot Thermowell Protective well Pockets -blocked- STANDARD LH-DE011017-REV02 Instrumentation and control components (non electrical) Sensors if not structurally integrally with *QP*, metering orifice Signalling device Controller Flybolt governor Measuring instrument Testing equipment Measurement piping Instrument piping Condensation chambers (datum reservoir) in measuring circuits Thermowells and pockets for protection of sensors -blocked- AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 117/124 KKS - MASTERLIST X Signal origins XA Binary signals (from group control) XB Binary signals (from drive control) XB01 On Opened Off Closed Ready Test position Fault XB02 XB03 XB04 XB07 XB08 XB09 XB10 XB11 XB12 XB13 XB19 XB41 XB42 XB48 Service position Earthing switch closed Earth fault Under voltage Under voltage Under voltage Trip Emergency stop Status remote Status Local Spring drive charged Torque switch for open Torque switch for close Motor protection Thermistor unit pre-alarm Motor protection Thermistor unit trip Breaker tripping signal Reset Status Automatic XB49 Status Manual XB51 XB57 Not switched on Not opened Not switched off Not closed No faults XB58 XB72 XB73 XB91 XB92 no underload Not remote Not local Breaker not tripped Not reseted XB22 XB23 XB25 XB27 XB28 XB38 XB39 XB52 AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 Project: Document No.: STANDARD LH-DE011017-REV02 Signal origins Note: these signals are system specific and has to be fixed individually to the project, standard as follows Functional group control Subloop control Open loop drive control Control interface Feedback drive, solenoid valve, circuit breaker Feedback position Feedback drive, solenoid valve, circuit breaker Feedback position Feedback drive, circuit breaker Feedback drive, circuit breaker Feedback drive, actuator, solenoid valve, circuit breaker Feedback switch gear (field locked) Feedback switch gear Feedback switch gear Feedback busbar Feedback incoming Feedback battery Feedback drive, actuator Feedback plant, drive, actuator Feedback plant, drive, actuator Feedback MCC, circuit breaker Feedback actuator Feedback actuator Feedback MCC Feedback MCC Feedback circuit breaker Feedback MCC, plant Feedback control block e.g. drive, actuator, solenoid valve Feedback control block e.g. drive, actuator, solenoid valve Feedback drive, solenoid valve, circuit breaker Feedback position Feedback drive, solenoid valve, circuit breaker Feedback position Feedback drive, actuator, solenoid valve, circuit breaker Feedback from switchgear (MCC) Feedback plant, drive, actuator Feedback plant, drive, actuator Feedback MCC, circuit breaker Feedback plant C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 118/124 KKS - MASTERLIST XC Binary signals (feedback from controllers) XC01 XC02 XC03 XC04 XC07 XC57 XG (free for use) (free for use) Control automatic Control manual Control disturbance No control disturbance Binary signals (from field/process) XG01 Switched on Opened/open Limit setpoint >max 1 Switched off Closed/close Limit setpoint <min 1 Limit setpoint >max 2 Limit setpoint <min 2 Limit setpoint >max 3 Limit setpoint <min 3 Limit setpoint >max 4 Limit setpoint <min 4 Limit setpoint >max 5 Limit setpoint <min 5 Limit setpoint <max 1 Switched on Opened/open Switched off Closed/close Limit setpoint >min 1 Limit setpoint <max 2 Limit setpoint >min 2 Limit setpoint <max 3 Limit setpoint >min 3 Limit setpoint <max 4 Limit setpoint >min 4 Limit setpoint <max 5 Limit setpoint >min 5 XG02 XG03 XG04 XG05 XG06 XG07 XG08 XG09 XG10 XG51 XG52 XG53 XG54 XG55 XG56 XG57 XG58 XG59 XG60 AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 Project: Document No.: STANDARD LH-DE011017-REV02 Closed-loop control signals (binary feedback, only used internally from system as local tag, not for signals from/to field). Rem.: will be not shown normally! Feedback controller Feedback controller Feedback controller Feedback controller Feedback controller Feedback controller Binary process signals (even conditioned by binary condit. modules) e.g. all typical field signals (pressure switch, limit switch …) Feedback NO-contact Feedback NO-contact Feedback NO-contact Feedback NO-contact Feedback NO-contact Feedback NO-contact Feedback NO-contact Feedback NO-contact Feedback NO-contact Feedback NO-contact Feedback NC-contact Feedback NC-contact Feedback NC-contact Feedback NC-contact Feedback NC-contact Feedback NC-contact Feedback NC-contact Feedback NC-contact Feedback NC-contact Feedback NC-contact C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 119/124 KKS - MASTERLIST XH Binary limit signals XH01 XH02 XH03 XH04 XH05 XH06 XH07 XH08 XH09 XH10 XH51 XH52 XH53 XH54 XH55 XH56 XH57 XH58 XH59 XH60 XJ Limit setpoint >max 1 Limit setpoint <min 1 Limit setpoint >max 2 Limit setpoint <min 2 Limit setpoint >max 3 Limit setpoint <min 3 Limit setpoint >max 4 Limit setpoint <min 4 Limit setpoint >max 5 Limit setpoint <min 5 Limit setpoint <max 1 Limit setpoint >min 1 Limit setpoint <max 2 Limit setpoint >min 2 Limit setpoint <max 3 Limit setpoint >min 3 Limit setpoint <max 4 Limit setpoint >min 4 Limit setpoint <max 5 Limit setpoint >min 5 Black box signals XJ01 switched-on in operation switched-off not in operation Ready Status remote Status local Binary signals Protection signal no protection signal Binary signals (from control rooms and PBstations/panels) XJ02 XJ03 XJ22 XJ23 XK XK01 XK51 XL XL01 XL02 XL04 XL15 XL16 XL21 XL22 XL41 XL42 Control on Control off Acknowledge Automatic on Automatic off Preselection 1 on Preselection 2 on Open Start-up Close Shut-down Project: Document No.: STANDARD LH-DE011017-REV02 Binary limit signals derived from analog process signals Positive logic (log=1) Positive logic (log=1) Positive logic (log=1) Positive logic (log=1) Positive logic (log=1) Positive logic (log=1) Positive logic (log=1) Positive logic (log=1) Positive logic (log=1) Positive logic (log=1) Negative logic (log=0) Negative logic (log=0) Negative logic (log=0) Negative logic (log=0) Negative logic (log=0) Negative logic (log=0) Negative logic (log=0) Negative logic (log=0) Negative logic (log=0) Negative logic (log=0) Signals from non-standard areas (e.g. black box), (shall be fixed individually), but alarms shall be defined under *XM*. Feedback from black-box Feedback from black-box Feedback from black-box Feedback from black-box Feedback from black-box Equipment unit/component protection e.g. Generator protection (log=1) e.g. Generator protection (log=0) Control room and control stations, signals not assigned to specific control systems (e.g. control interface tiles, PB-stations will be identified by the drive-No.) Start commands for subloop control Stop commands for subloop control Acknowledging signal Start command automatic Stop command automatic Cmd-On preselection 1 Cmd-On preselection 2 Command for the System Command for the System AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 120/124 KKS - MASTERLIST XM Common alarms/faults (binary) XM01 XM02 XM03 XM04 XM05 XM06 XM07 XM08 XM09 XM10 XM11 XM12 XM13 XM14 XM21 XM22 XM23 XM24 XM33 XM41 XM42 XM49 XM51 XM52 XM53 XM54 XM55 XM56 XM79 XM80 XM90 XN Fault 1 Fault 2 Fault 3 Fault 4 Fault 5 Fault 6 Fault 7 Fault 8 Fault 9 Fault 10 Disturbance measurement Fault 2 v 3 common Fault 2 v 3 analog Fault 2 v 3 binary Fault plant Breaker tripping signal Non-equivalence Run time error Sensor fault (analog/binary) Message Message Fault switch-over activated Voltage 0.4kV fault Voltage 220/240V AC fault Voltage 110/220V DC fault Voltage 24/48V AC fault Voltage 24/48V DC fault Signal voltage fault Under voltage (common) Common alarm/fault black box Device fault (common fault) Binary signals XP Binary signals XQ XQ01 Analog signals (from field/process) Analog value 1 XQ02 XQ03 XR Analog value 2 Analog value 3 Analog signals (internal controller signals) XR01 XR02 XR03 XR07 XR11 Control deviation Setpoint 1 Setpoint 2 Disturbance signal Adjustment command Control command AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 Project: Document No.: STANDARD LH-DE011017-REV02 Higher-level static individual and group alarm e.g. common alarms from black boxes Fault, alarm Fault, alarm Fault, alarm Fault, alarm Fault, alarm Fault, alarm Fault, alarm Fault, alarm Fault, alarm Fault, alarm Fault, alarm Fault, alarm Fault, alarm Fault, alarm Fault, alarm Fault, alarm Fault, alarm Fault, alarm Fault, alarm Control system Control system Fault, alarm Fault, alarm Fault, alarm Fault, alarm Fault, alarm Fault, alarm Fault, alarm Fault, alarm Fault, alarm Fault, alarm Status-display computer (please do not use) Supervisory computer (please do not use) Process signal (analog) Analog input signal (from Transmitter to DCS or PLC) If transmitter has two analog outputs If transmitter has three analog outputs Closed loop control (analog signals, only used internally from system as local tag, not for signals from/to field). Rem.: will be not shown normally! Closed loop control Referent input variable 1 Referent input variable 2 Closed loop control Closed loop control, from controller to controller C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 121/124 KKS - MASTERLIST XS XS01 XT XU Binary signals Start sequence step 1 On Start sequence step 2 On Start sequence step 3 On Start sequence step 4 On Start sequence step 5 On Stop sequence step 1 On Stop sequence step 2 On Stop sequence step 3 On Stop sequence step 4 On Stop sequence step 5 On Binary signals from DCS Turbine-Generator Higher-level signals from DCS XU11 XU12 XU13 XU14 XU15 XU16 XU17 XU21 XU22 XV XW Control available Control not available Control in operation Control not in operation Control automatic Control manual Control stop Preselection 1 selected Preselection 2 selected Signal gating protective logics Binary signals XS02 XS03 XS04 XS05 XS51 XS52 XS53 XS54 XS55 AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 Project: Document No.: STANDARD LH-DE011017-REV02 Functional group control step signal Functional group control step signal Functional group control step signal Functional group control step signal Functional group control step signal Functional group control step signal Functional group control step signal Functional group control step signal Functional group control step signal Functional group control step signal Functional group control step signal Binary signals from DCS Turbine-Generator Higher-level dynamic individual and group alarm (from DCS) Feedback signal Feedback signal Feedback signal Feedback signal Feedback signal Feedback signal Feedback signal Feedback signal Feedback signal Signal gating (protective logic, alarm logic, etc.) Hardwired annunciation systems (please do not use) C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 122/124 Project: Document No.: KKS - MASTERLIST Y Signal applications YA Binary signals (output signals) YB Binary signals (output signals) YB01 Switch on Open Switch off close Hold Stop Protection off Emergency stop Forced open Forced close Time synchronisation Binary signals (from control system) Analog signals (from control system) Adjustment command Control command Analog signals internal YB02 YB03 YB31 YB32 YB41 YB42 YM01 YP YQ YQ01 YR AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 STANDARD LH-DE011017-REV02 Identification of type of action by the use of the control signal (eg. Output signal of control block to field/MCC) Note: these signals are system specific and has to be fixed individually to the project, standard as follows Functional group control Subloop control Open loop drive control Control interface Output command Output command Output command Trip input command Trip command Command Command Sync-signal Joint control computer Setpoints (output signal) Control signal to actuator Controller C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 123/124 KKS - MASTERLIST Z Gated signals ZB01 ZB07 Binary signals Fault ZB08 ZB57 Underload no fault ZB58 no underload ZV Signal gating protective logics AT-DE / H. Eder erstellt am / created 2001-10-17 geändert am / modified 2006-11-27 gedruckt am / printed 2006-11-27 Project: Document No.: STANDARD LH-DE011017-REV02 Subgroups are established as appropriate to the type of instrumentation and control system and are therefore subject to agreement between the parties to the project Combined feedback signal Combined feedback signal drive, actuator, solenoid valve, circuit breaker Feedback from switchgear (MCC) Combined feedback signal drive, actuator, solenoid valve, circuit breaker (Note: for new plants please use *XB57*) Feedback from switchgear (MCC) (Note: for new plants please use *XB58*) Signal gating protective logics (shall be fixed individually) C:\temp\KKS-MasterList-Hydro-english-REV02.doc Sprache / Language: EN Dokumentenart / Documenttype: EN-DOC geprüft von/am / checked by/on: Dendl / 2006-11-27 124/124
0
You can add this document to your study collection(s)
Sign in Available only to authorized usersYou can add this document to your saved list
Sign in Available only to authorized users(For complaints, use another form )