Aqseptence rif.:
ROFI-0181-17-R2
Title:
PRELIMINARY ELECTRIC MOTOR LIST
PROJECT NAME:
FILTERPRESS MODEL :
FILTERPRESS
INSTALLED POWER
POWER CONSUMPTION CALCULATION
TOTAL
Number of
number into
unit in duty
plant
Notes
RUN time of the
motor every single
filtration cycle
[min./cycle]
Number of daily
cycle of the motor
for N.1 filter
[N./day]
Daily RUN time of
the motor for N.1
filter
[h./day]
16,60
72,63
20,09
0,8
1012,69
1,00
1012,69
Filter open/close, driptray open/close, shaking.
Daily WAITING time Service factor and
of the motor
efficiency
[h./day]
(during RUN time)
Service factor and
efficiency
(during WAITING
time)
Daily electric Daily electric
Daily electric
consumption consumption Moltiplication consumption
RUN time
WAITING
factor
for the plant
[kWh/day]
[kWh/day]
[kWh/day]
Notes
Service
kW
Operation
Hydraulic Unit (motor 1)
63
Discontinuous
1
1
480V/50Hz/3Ph.
Hydraulic Unit (motor 2)
63
Discontinuous
1
1
480V/50Hz/3Ph.
6,17
72,63
7,46
0,8
376,20
1,00
376,20
Filter open/close, driptray open/close, shaking.
Hydraulic Unit (recirculation)
15,4
Discontinuous
1
1
480V/50Hz/3Ph.
16,60
72,63
20,09
0,8
247,55
1,00
247,55
Filter open/close, driptray open/close, shaking.
Hydraulic Unit (cooler)
1,27
Discontinuous
1
1
480V/50Hz/3Ph.
16,60
72,63
20,09
0,8
20,41
1,00
20,41
Filter open/close, driptray open/close, shaking.
Cloth washing robot (motor 1)
3
Discontinuous
1
1
480V/50Hz/3Ph.
0,13
162,40
0,34
0,8
0,81
1,00
0,81
High pressure cloth washing.
Cloth washing robot (motor 2)
3
Discontinuous
1
1
480V/50Hz/3Ph.
72,45
1,01
1,22
0,7
2,56
1,00
2,56
High pressure cloth washing.
220
Continuous
1
1
480V/50Hz/3Ph.
16,6
72,63
20,09
0,7
3057,04
1,00
3057,04
BELT
CONVE
YOR
HIGH
PRESSURE
CLOTH WASH
PUMP
Piston pump
250
Discontinuous
2
1
480V/50Hz/3Ph.
LOW
PRESSURE
CLOTH WASH
PUMP
TOT. kW=
Belt conveyor drive
Centrifugal pump
110
Discontinuous
2
1
480V/50Hz/3Ph.
596,5599
Discontinuous
1
1
480V/50Hz/3Ph.
400
Discontinuous
2
2
480V/50Hz/3Ph.
TOT. kW=
TOT. kW=
FEEDING
PUMP
CAKE
BLOWING UNIT
TOT. kW=
Centrifugal Feeding pump
Lubricated screw compressor
TOT. kW=
TOT. kW=
148,67
220
147
1,01
2,47
0,8
494,26
1,166666667
72,63
1,41
22,59
0,8
0
124,27
5,6
72,63
6,78
17,22
0,8
0,8
15,9
72,63
19,25
4,75
1
0,3
1660,22
TOT. kWh / day=
3057,04
1,00
494,26
N.1 daily high pressure washing per filter
0,00
1,00
124,27
Filling and compacting times.
3234,96
8218,99
1,00
11453,95
Filling and compacting times.
7698,29
570,51
2,00
16537,61
Estimated: 40 min. of ON time during a 56 min.
500
TOT. kWh / day=
220
TOT. kWh / day=
596,5599
TOT. kWh / day=
800
NOTES
TOT. kWh / day=
TOT. kWh / day=
494,26
124,27
11453,95
16537,61
NOTES
Estimated total installed power:
TOT. kW
2485,2299
PRELIMINARY CALCULATION VALID FOR OFFER
Rev
Date
Description
00
1/03/19
First issue
Estimated total absorbed power:
PRELIMINARY CALCULATION VALID FOR OFFER
Prepared
Checked
Sheet
1 of 1
NOTE:
- Syscad compila unicamente le celle in giallo, per il resto il report è un semplice foglio excel senza macro modificabile a piacere;
- Se necessario il valore delle celle in giallo può essere modificato manualmente senza limitazioni.
TOT. kWh/day=
33327,3
day/year=
365
MWh/year=
12164,48