To be a global leader in the subdivision field of medical equipment manufacturer manufacturer M30 Color Doppler Ultrasound Diagnostic system Technical Specification Release version: V 1.0 Version: 1.0 2023-03 1 M30 Technical Specifications To be a global leader in the subdivision field of medical equipment manufacturer measurement technology ,4D volume 1 Overview of the system imaging technology and other M30 Based on the new CPU + GPU dual ultrasonic imaging technology, can be processor heterogeneous computing widely used in abdominal, superficial technology, the organs, blood vessels, adult heart, high-speed imaging platform uSeed solves metadata pediatric technology the heart, reproductive, technical maternity, breast, musculoskeletal, and difficulties of high loss in the front-end other fields, is a high quality portable signal processing of the traditional ultrasonic machine. ultrasonic platform, and the hardware 1.1 Check mode with higher circuit integration, stronger performance and faster abdomen response cardiac speed. M30 in order to meet the market and clinical gynaecology development, obstetrical improve the image resolution, increase the clinical application Urology function, blood vessel reliable stability and so on to develop small organ this product. Its fusion of harmonic imaging technology, elastography technology,panoramic imaging Mechanurgy emergency user-defined technology, spatial composite imaging technology, PW Version: 1.0 2023-03 automatic 2 M30 Technical Specifications To be a global leader in the subdivision field of medical equipment manufacturer 1.2 Probe type TDI imaging 3D mode convex array 4D mode linear array 1.4 Language phased array intracavity Software: Micro-convex Chinese, English, French, Spanish, Russian 4D volume Keyboard 1.3 Imaging mode input: Chinese and English B mode 2 Physical specifications 2B mode 2.1 Size and weight 4B mode M mode Width: 380mm anatomic M mode Height: 361.5mm Color-based CM mode Thickness:157.2mm Color mode Weight: about 6.5kg PDI mode 2.2 probe port and hanging cup DPDI mode Probe port: 2 fully active probe CW mode ports + 1 park PW mode Detachable probe hanging cup: 3 panoramic imaging standard equipped Elastic imaging Version: 1.0 2023-03 3 M30 Technical Specifications To be a global leader in the subdivision field of medical equipment manufacturer 2.3 Power supply Power supply 1060 hPa voltage: 3 Human-computer 100V-240VAC interaction Power supply frequency: 50Hz / 3.1 Display 60Hz Input power: 150VA Battery 15.6-inch specification: high-resolution color LED display 14.4V/9500mAh Resolution: 1920*1080 Display screen folded up and down: 2.4 Operating environment 90 degrees Ambient temperature: 5℃ ~40℃ 3.2 The Control Panel Relative humidity: 25%~85% Atmospheric pressure: 700 hPa ~ User-centered 1060 hPa design for easy operation Panel 2.5 Transportation and storage button backlight design: level 0-9 adjustable environment Power switch Ambient temperature: -20 ℃ ~ + Image mode key 55℃ -B、C、PW、M、Dual、Quad、3D/4D、 Relative humidity: 10% to 95% PDI、CW、TDI、ECG、Biopsy (non-condensing) 6 user-defined keys Atmospheric pressure: 700 hPa ~ Version: 1.0 2023-03 - Q1-Q4 4 M30 Technical Specifications To be a global leader in the subdivision field of medical equipment manufacturer - Save 1/Save 2 - Workstation 8-segment TGC slide - Setting Parameter shortcut key -Qsave User-defined parameters - Depth - body label - Focus position - Arrow - Gain/automatic optimization - Text - Angle/deflection Standard text keyboard - Baseline Dedicated palm placement area to - range reduce wrist fatigue injury Function key Trackball - Probe/check switch Key tone and trackball sensitivity is - Patient Information adjustable - Report Indicator light - Browse - External power indicator - End check - Battery status indicator - Print - Hard disk operating indicator - Clear 3.3 System switch machine - Cursor The cold start time of the system is - Apply the measurement key about 90 seconds - Regular measurement key The shutdown time is about 5 - Refresh key seconds - Confirm key Version: 1.0 2023-03 5 M30 Technical Specifications To be a global leader in the subdivision field of medical equipment manufacturer - Battery power System sleep - Screensaver program: close, 1, Image area - Measuring items 10, 30, 60min - text comment - Standby program: shut down, 1, - arrow comment 10, 30, 60min - Body mark 3.4 Screen information Parameter display area herder area paste area - ZONCARE Identification Parameter menu display area - Hospital name 4 Image parameters - Operator - Patient information (name, ID, 4.1 Overview gender, age) Digital beamformer - Check date Multiplex signal parallel processing - Check time technology - Sound power Digital full-process dynamic focus - Mechanical Index (MI) Digital - Soft tissue heat index (TIS) variable aperture and dynamic track change technology - Bone heat Index (TIB) A/D :14bit - cranial heat index (TIC) - Probe type 4.2 B mode - Check mode Gain: 0-400 dB, step 1 Version: 1.0 2023-03 6 M30 Technical Specifications To be a global leader in the subdivision field of medical equipment manufacturer TGC: the 8th segment Frame correlation: 0-6, step 1 Display Depth: 420mm Line density: Image quality: Pen, Gen, Res, HPen, - Low and high hpen-gen, HGen, HRes Harmonic imaging - Low, medium, high and super (THI tissue high (phased array probe) harmonics) Tissue Gray scale: 1-10, step 1 imaging: conventional, ZClear: 0-6, step 1 muscle, fat, fluid 2B Extended imaging:0,1,2 4B full screen: 0.8、0.9、1.0、1.1、1.2、 turn upside down 1.4、1.6、1.8、2.0、3.0、4.0、5.0、 Mirror 6.0、7.0、8.0、9.0、10.0 A.Power: 5%-100%, step 5 (1-20) Deflection: -17°, -12°, -8°, -5°, 0°, 5°, 4.3 M mode 10°, 12°, 17° (linear array probe) Gain: 0~400dB, step 1 Dynamic range: 30-180 dB, step 5 Dynamic range: 30-180, step 5 focus point - Number of foci: 1-8 adjustable Gray scale: 1-10, step 1 - Focus position: 15 positions Pseudocolor: 0-8, step 1 - Focus spacing adjustable Scan speed: 1-6,step 1 Space compound: 0-7, step Display format: V2:3, V3:2, V3:1, 1 H2:3, full screen (according to different probes) Pseudocolor: 0-8, step 1 Version: 1.0 2023-03 7 M30 Technical Specifications To be a global leader in the subdivision field of medical equipment manufacturer 4.4 Color / PDI / DPDI mode 2B 4B Gain: 0-400, step 1 Sampling box deflection: -28°、-22°、 Display mode -15°、-8°、0°、8°、15°、22°、28° - Double color Color map - Four in colour - V0-V10(speed type) -B+C Dual real-time - VV0-VV9 ( Velocity variance Image quality: Pen, Gen, Res type) PRF :0.2-7.9k 4.5PW/CW mode Smooth:1-4, step 1 Wall filter: 0-7, step 1 Gain: 0-400, step 1 Line density: spectrum inversion - Low and high Automatic envelope: 7 calculation - Low, medium, high and super parameters high (phased array probe) PRF :0.5k-12.0k Color priority: 0-100, step 1 Baseline: 17 gear Frame rate: adjustable Sampling volume: 0.5-80mm,step Speed marker: On, off 0.5 One key optimization Angle correction: ± 80°, step 1 Dual real-time (C / B, C / P, C / DP) Quick Angle Correction: -60 ° ,0 ° , Color reversal 60° Color scale expansion Pseudocolor: 0-8, step 1 Color hidden Version: 1.0 2023-03 8 M30 Technical Specifications To be a global leader in the subdivision field of medical equipment manufacturer Dynamic range: 24-72, step 2 and structure of the human body, Wall filter: 0-7, step 1 so as to obtain more useful Gray scale chart: 0-10, step 1 reference information. One key optimization Scanning Display format: V2:3, V3:2, V3:1, quality: lowest, low, medium, high, highest H2:3, full screen Scanning Angle: 10-70° HPRF: On and off Threshold: 0 to 100, step 1 Automatic calculation: on and off Opacity: 0-100, step by 5 Automatic calculation parameters: Smooth: 0-12, step 1 AT, D/S, DT, ED, Flow (TAMAX), Brightness: 0-100, step by 1 Flow (TAMEAN), HR, MD, MMPG, Contrast ratio: 0-100, step 1 MPG, PI, PPG, PS, PV, RI, S/D, False color: 0-8, step 1 TAMAX, TAMEAN, VTI Gray Scale Map: 1-10, step 1 (MPR Automatic calculation cycle: 1, 2, 3 view) Image enhancement 0-10, step 1 4.6 3D / 4D imaging Relationship between MPR and VR The 3D / 4D function can display two-dimensional three-dimensional view and images Toggle display format in - Single image various ways, and facilitate the - Double image three-dimensional and intuitive - Four images are symmetrical observation of the morphology Version: 1.0 2023-03 - Four unsymmetrical images 9 M30 Technical Specifications To be a global leader in the subdivision field of medical equipment manufacturer Face recognition (VR view) - Distance: 0.1-40, step 0.1 Render modes: Surface, Depth, - Profile full screen Max, Min, X Ray, Zlive, Silhouette Page layout Select images: A, B, C, VR - Niche imaging Rotating image - From front to back - Axial rotation (along X, Y, Z axes) - From back to front - Rapid rotation (0°, 90°, 180°, -90° -A, B, C, niches along the Z-axis) Automatic rotation Reverse view 4.7 Anatomical M mode Hedral synchronization Anatomical M mode imaging can Inversion imaging analyze Volume of interest (VOI) location and direction of the two-dimensional Reset the VOI clipping line image, Zoom image so as to obtain the movement trajectory of the local Reset myocardium in the region of Clipping interest. ZPage The functional information of the tissue can be - Section layout: 2*2, 3*3, 4*4, 5*5 evaluated more accurately and - Section orientation, horizontal, comprehensively by comparing vertical multiple - Section selection: A, B, C 2023-03 sampling lines and images at different times. - Profile position: -12~12, step 1 Version: 1.0 any 10 M30 Technical Specifications To be a global leader in the subdivision field of medical equipment manufacturer Support three sampling lines: A, B Parameters were adjusted with the and C M type Sampling line position: any 4.8 Tissue the Doppler and strain adjustable rate imaging mode Direction of sampling line: 0-360 ° The TDI mode obtains motion rotation information Show / hide partial sampling lines Display format: left and and generates color-coded imaging of tissue right movement speed. display, up and down display The Gray scale map: 1-10, step 1 strain rate is the spatial gradient of the velocity data Speed: 1-6, step 1 calculated from the TDI. Strain False color: 0-8, step 1 rate 4.9 Color M mode imaging deformation The color M mode superimposed direction information about blood flow or Imaging mode shows tissue the beam in tissue on the M mode image to - Tissue Doppler velocity chart provide cardiac motion. Because (TVI) it - Tissue Doppler energy map is more sensitive to the instantaneous changes of the (TPI) motor signal, it can provide more - Organizing detailed diagnostic information. Spectrum Map (TVD) Version: 1.0 2023-03 11 the Doppler M30 Technical Specifications To be a global leader in the subdivision field of medical equipment manufacturer 4.10 Elastography - Tissue Doppler Color Type M (TVM) Elastomography * This mode is only applicable for the of 4.11 Wide-view imaging by manually the relative hardness of the tissue to determine the tissue hardness ordinary of the mass. ultrasound imaging, wide-view Pressure indicator stick imaging provides a whole new Strain ratio measurement perspective for clinical diagnosis, Smooth :0-6, step 1 and has a very important clinical Opacity :0-10, step 1 diagnostic significance for the Map :1-7, step 1 observation of larger lesions and Flip the relationship between lesions Synchronization and surrounding tissues. 4.12 Ultrasound assistant The B, Color, and PDI modes are supported It Rethe view image includes diagram, Support the abdomen, superficial ultrasound operation image technique diagram, operation instructions probe and 2023-03 tissue human respiration, and quantify ultra-wide visual field imaging. Version: 1.0 the applying slight pressure or using Wide-view imaging, also known as with the distribution of elastic properties phased array probes. Compared shows 12 clinical anatomical map, M30 Technical Specifications To be a global leader in the subdivision field of medical equipment manufacturer 4.13 SCI providing users with operation guidance for ultrasound Spatial composite imaging examination. Support the Level 0-7 adjustable single-window Paper clip test: > 9 lines amplification function Cannot be used concurrently with Support parts: extended imaging/FCI - liver The phased-array probe is not - Gall bladder supported - spleen 4.15 AUTO - kidney - pancreas One-click automatic optimization - arteria carotis Automatic - thyroid gland optimization of parameters - heart - Mode B: Gain, frequency, dynamic range, spatial composite, 4.14 Contrast imaging pseudo-color, frame correlation, Display layout: single frame, B / line density, gray scale, noise Contrast double frame suppression, brightness, contrast, Timer 1 curve, LGC Timer 2 - Mode C: Gain, PRF, Frame Support for all of the probes correlation, smoothing, wall filtering, color scale map, line Version: 1.0 2023-03 13 M30 Technical Specifications To be a global leader in the subdivision field of medical equipment manufacturer density, frequency, B suppression, imaging color priority, frame rate, sound Phased power, speed pass, baseline - PW mode: Gain, array, micro-convex, volume probe are not supported range, 5 Cine playback dynamic range, baseline Available in all modes 4.16 Zoom Supports frame-by-frame manual Local zoom: 16 levels adjustable playback and automatic playback Overall scaling: Support front-end and back-end with adjustable speed magnification, Automatic playback speed: ×1/10, magnification ratio ≥10 times, 16 ×1/5, ×1/4, ×1/3, ×1/2, ×1, ×2, level adjustable ×3, OFF Back to the final frame 4.17 The puncture guidance Set the first frame Puncture assembly (optional) Movie / single frame Single line / double line Type of puncture: Maximum playback frame number single line, in 2 D: 9945 frames double line Angle Forward storage: 1-120s adjustment: 30-50 ° Backward storage: 1-480s adjustable,step 0.5 Location: Adjustable Support Version: 1.0 for spatial 2023-03 composite 14 M30 Technical Specifications To be a global leader in the subdivision field of medical equipment manufacturer 6 Measurement and -IMT analysis -strain ratio M mode 6.1 General measurement - Distance 2D mode - Time - Distance - slope - Depth - Heart rate - Curve length (trace, spline) - Speed - Angle Doppler mode - Area and circumference (trace, - time ellipse, spline, reticle) - heart rate - Volume (three-distance, ellipse, - Speed ellipse distance) - Acceleration - double distance -D Indicates the trace - Parallel lines -PS/ED -length ratio - Blood flow -area ratio -velocity ratio -B Histogram (trace, ellipse, -VTI ratio spline, rectangle) 6.2 - sectional view Clinical application of measurement package - Color Speed (8 dots) abdomen - Blood flow Version: 1.0 2023-03 15 M30 Technical Specifications To be a global leader in the subdivision field of medical equipment manufacturer 2D mode post - Kidney: kidney length diameter, diameter, post urinary bladder kidney wide diameter, kidney thickness diameter, post urinary thickness bladder volume, diameter, and kidney kidney cortex urinary bladder width length diameter, post urinary bladder volume thickness - Ureter - Gallbladder: gallbladder long - Urine output diameter, gallbladder thick Doppler mode diameter, gallbladder wall - Renal thickness vessels: artery, - Pancreas: pancreatic pancreatic head, duct, main renal segment artery, interlobar artery, arch artery - Abdominal artery: abdominal pancreatic body, and pancreatic tail aorta, celiac trunk, superior - Bifurcation of the abdominal mesenteric artery, inferior aorta mesenteric artery, common - Preurinary bladder volume: hepatic artery, bile native preurinary bladder length diameter, preurinary bladder - Abdominal vein: inferior vena thickness diameter, preurinary cava, inferior vena cava reflux, bladder width diameter, portal vein, left hepatic vein, artery, and splenic artery preurinary bladder volume middle hepatic vein, right - Post urinary bladder volume: hepatic vein, splenic vein, Version: 1.0 2023-03 16 M30 Technical Specifications To be a global leader in the subdivision field of medical equipment manufacturer superior mesenteric vein, and cerebellar anterior diameter, inferior mesenteric vein posterior fossa, lateral ventricular obstetrical width, cerebral B mode external eye distance, eye - Fetal routine (double apical distance, eye distance, ear diameter, circumference, distance, orbit, ear circumference, mandible, skull layer, cervical fold, head abdominal hemisphere, length, femoral length, occipital frontal chest diameter) diameter, chest diameter, chest - Uterus volume diameter, - Cervical volume abdomen, abdominal diameter, - Endar thickness trunk - Ovarian volume circumference, heart area, trunk - ovarian follicle 1 volume thickness diameter, transverse diameter - Pregnant sac (long, wide, circumference, posterior chest diameter, diameter, heart trunk , Trunk thick) transection, - The gestational sac diameter transverse diameter, abdominal - saccus omphaloentericus thickness diameter, - Head and hip diameter gallbladder, kidney - Transparent layer of neck stomach, - Advanced bladder volume, clavicle length, measurement (cerebellar transverse diameter, Version: 1.0 2023-03 humerus 17 abdominal bulb, length, liver, volume, duodenum, ulna length, M30 Technical Specifications To be a global leader in the subdivision field of medical equipment manufacturer radius length, middle segment Axis, four) phalanx, tibia fibula - Automatic head circumference length, vertebra foot - voluntarily NT length, length, length, umbilical artery, umbilical M mode vein) - LVIDd - Placental thickness - LVIDs - The depth of amniotic fluid - RVIDd - Amniotic fluid index (A F1, A - RVIDs F2, A F3, A F4, amniotic fluid - IVSd index) - IVSs - Fetal heart with (LVIDd, LVIDs, - fetal heart frequency LV Diam, L A Diam, R VID d, R VID Doppler mode s, RV Diam, RA Diam, IVS d, IVS s, - arteria umbilicalis IVS, L V Area, L A Area, R V Area, R - canal of Arantius A Area, AO Diam, MPA Diam, L - Placental artery OVT Diam, ROVT Diam, M V - arteriae cerebri media Diam - Fetal aorta , PV Diam, AO Asc Diam, AO Desc Diam, Duct Art Diam, TV - aorta descendens Diam, LPA Diam, RPA Diam, A V - arteriae uterina Diam, IVC Diam, - arteriae ovarica - Z-score (LV Long Axis, Ao rtic - aorta ascendens Arch, Ao Short Axis, Ao ObI, Short - LV outflow tract Version: 1.0 2023-03 18 M30 Technical Specifications To be a global leader in the subdivision field of medical equipment manufacturer - outflow tract of right ventricle - Vessels (Vascular):Ao Diam, Ao - fetal heart frequency Arch Diam, Ao Asc Diam, Ao Desc Multifetal measurement Diam, LVOT Diam, MPA Diam, - Up to 8 fetuses were measured RVOT Diam, IVC Diam(Insp), IVC Fetal growth curves Diam(Expir), Ao Isthmus, Ao st Fetal physiological score junct, Ao Sinus Diam) cardiac - Mitral Valve (Mitral valve): MV B mode Diam, MVA, MCS, M V EPSS - Dimensions (Distance from):L - Tricuspid V Diam, LA Major, LA Minor, RA valve): TV Diam, TVA Major, RA Minor, LV Major, LV - Aortic Valve (Aortic valve): AV Minor, Diam, ACS, AVA RV Major, RV Minor, Valve (Tricuspid RVAWd, RVIDd, IVSd, LVIDd, L - Pulmonic VPWd, RVAWs, RVIDs, IVSs, LVIDs, artery valve): PV Diam, LPA Diam, LVPWs, LVLd RPA Diam, MPA Diam apical, LVL s apical, Valve (Pulmonary LVOT Diam, RVOT Diam, Ao Diam - Shunts - Area (area):LA Area, RA Area, ASD Diam, PDA Diam, P re Ductal, LV Area(d), LV Area(s), RV Area(d), P ost Ductal, PFO Diam RV Area(s), LVAd sax MV, LVA s - Other (SVC Diam (Insp), SVC sax MV, LVAd apical, LVA s apical, Diam (Expir), LCA Diam, RCA LVA d sax E pi, LVAd sax Endo, A Diam, PEd, PEs) VA M mode Version: 1.0 2023-03 19 (Shunt): VSD Diam, M30 Technical Specifications To be a global leader in the subdivision field of medical equipment manufacturer - HR - Mitral Valve (Mitral valve):HR, E - Aortic Valve (Aortic valve):Ao Vel, A Vel, Ac T, DecT, E 'V elsep, A' Diam, LA Diam, ET, Ao V Diam, Ao Velsep, E ' Vellat, A' Arch Diam, Ao Asc Diam, Ao D A Dur, IVRT, IVCT, MV V Trace, M V esc Diam, Ao Isthmus, Ao stjunct, Dist A, MV Dist B, MVA (PHT), dp Ao S inus Diam, LVOT Diam, ACS /dt, MV V max, MV E VTI, M V A V - Mitral valve): TI, MR Vmax, MV A (VTI), LVOT EPSS, CE Amp, CA Amp, EF Slope, Diam, LVOT VTI, MV VTI, MR VTI, DE Amp, DE Slope, MCS, PEd, PEs MS Vmax, LV Tei Index, MV C-O - Tricuspid dur, LVET Valve (Mitral Valve (tricuspid - Tricuspid Valve:TV E Vel,TV A valve): TAPSE - Pulmonic Vellat, E Dur, Valve (Pulmonary Vel,TV AcT,TV DcT,TV V Trace,TR artery valve): LPA Diam, RPA Diam, V MPA Diam, R VOT Diam Press,TVA(PHT),TV A Dur,RV Tei - Time (time): LVPEP, LVET, Trace,TV Vmax,TR Vmax,RA Index,TV C-O dur,RVET RVPEP, RVET - Pulmonic Doppler mode Trace,PV Diam,RV PEP,RV AcT,RV - Aortic Valve (Aortic valve):H R, ET,PV AoV V T race, LVOT V T race, LVOT Vmax,LPA Diam, Ac T, E T, AoV Vel, LVOT V el, Vmax,RVOT VTI,PR V Trace,PR A R V T race, Ao Diam, LA Diam, L Ved,PA Press) VPEP, AR Vel, AR DecT, AR PHT - Pulmonic Version: 1.0 2023-03 20 Valve:HR,PV Vmax,MPA V Vmax,RPA Vmax,RVOT Vein:S Vel,D M30 Technical Specifications To be a global leader in the subdivision field of medical equipment manufacturer Vel,Decel Time,PVA Vel,PVA Dur,S - EDV(BP) VTI,D VTI) - ESV(BP) - Shunts: Vmax,ASD - SV(BP) Vmax,PDA Vel(d),PDA Vel(s) - CO(BP) TDI - EF(BP) - MV Ea(medial) - SI(BP) - MV Aa(medial) - CI(BP) - MV ARa(medial) LV Auto EF - MV DRa(medial) - Automatically identify cardiac - MV Sa(medial) contraction - MV Ea(Iateral) automatically, - MV Aa(Iateral) ventricular profile and calculate, - MV Sa(Iateral) calculate the formula consistent - MV ARa(Iateral) with Simpson. - MV DRa(Iateral) LV(Cube) VSD Cardiac trace diastole, the - RVAWd Simpson - RVIDd - EDV(A2C) - IVSd - ESV(A2C) - LVIDd - EDV(A4C) - LVPWd - ESV(A4C) - RVAWs - HR - RVIDs Version: 1.0 and 2023-03 21 M30 Technical Specifications To be a global leader in the subdivision field of medical equipment manufacturer - IVSs - LVPWs - LVIDs - HR - LVPWs - EDV(Teichholz) - HR - ESV(Teichholz) - EDV(Cube) - SV(Teichholz) - ESV(Cube) - EF(Teichholz) - SV(Cube) - FS(Teichholz) - EF(Cube) - SI(Teichholz) - FS(Cube) - CO(Teichholz) - SI(Cube) - CI(Teichholz) - CO(Cube) LV(Gibson) - CI(Cube) - RVAWd LV(Teichholz) - RVIDd - RVAWd - IVSd - RVIDd - LVIDd - IVSd - LVPWd - LVIDd - RVAWs - LVPWd - RVIDs - RVAWs - IVSs - RVIDs - LVIDs - IVSs - LVPWs - LVIDs - HR Version: 1.0 2023-03 22 M30 Technical Specifications To be a global leader in the subdivision field of medical equipment manufacturer - EDV(Gibson) - LVALd - ESV(Gibson) - LVAMd - SV(Gibson) - LVIDd - EF(Gibson) - LVALs - FS(Gibson) - LVAMs - SI(Gibson) - LVIDs - CO(Gibson) - HR - CI(Gibson) - EDV(Biplane) LV(Bullet) - ESV(Biplane) - LVAWd - SV(Biplane) - LVId - CO(Biplane) - LVAMs - EF(Biplane) - LVLs - SI(Biplane) - HR - CI(Biplane) - EDV(Bullet) LV Mass - ESV(Bullet) LV Mass(Cube) - SV(Bullet) - IVSd - CO(Bullet) - LCIDd - EF(Bullet) - LVPWd - SI(Bullet) - LV Mass(Cube) - CI(Bullet) - LV Mass-I(Cube) LV(Biplane) LV Mass(A-L) Version: 1.0 2023-03 23 M30 Technical Specifications To be a global leader in the subdivision field of medical equipment manufacturer - LVAd sax Epi - RA Vol(A4C) - LVAd sax Endo TDI - LVLd apical - Ea/Aa(medial) - LV Mass(A-L) - ATa/Aa(medial) - LV Mass-I(A-L) - DTa/Aa(medial) LV Mass(T-E) - Ea/Aa(lateral) - LVAd sax Epi - ATa/Aa(lateral) - LVAd sax Endo - DTa/Aa(lateral) - a Vascular - b B mode - LV Mass(T-E) - Diameter stenosis ratio - LV Mass-I(T-E) - Area stenosis ratio LA Vol - IMT (rear wall) LA Vol(A-L) - IMT (front wall) - LA Diam Doppler mode - LAA(A2C) - Support the front wall and the - LAA(A4C) rear - LA Vol(A-L) measurement LA Vol(Simp) - - LA Vol(A2C) carotid artery, internal carotid - LA Vol(A4C) artery, RA Vol(Simp) artery, Version: 1.0 2023-03 24 wall Carotid with the arteries sinus, (common external vertebral screen carotid artery, M30 Technical Specifications To be a global leader in the subdivision field of medical equipment manufacturer subclavian artery, internal common femoral vein, superficial carotid/common carotid artery) femoral vein, deep femoral vein, - Arteries of the upper extremities great saphenous vein, popliteal (subclavian, brachial, vein, vertebral, posterior tibial vein, ulnar, axillary, radial, trunk tibiofibular peroneal innominate) vein, - Upper limb veins (subclavian gastrecnemius vein, axillary vein, cephalic vein, muscle vein) noble vein, ulnar vein, radial vein) - - Lower limb arteries (abdominal cerebral artery, anterior cerebral aorta, artery, artery, posterior cerebral artery, internal iliac artery, external iliac anterior communicating artery, artery, common femoral artery, posterior communicating artery, superficial femoral artery, deep basilar artery, internal carotid femoral artery, popliteal artery, artery, vertebral artery) trunk tibiofibular artery, posterior IMT tibial artery, dorsal pedis artery, - Support the front wall and the fibular rear common artery, iliac anterior tibial anterior vein, Intracranial wall tibial vein, vein, soleus vessels (middle with the screen artery) measurement - Lower limb veins (inferior vena - Automatic identification, the cava, common iliac vein, internal measured iliac maximum, minimum, mean, SD, Version: 1.0 vein, external 2023-03 iliac vein, 25 results show the M30 Technical Specifications To be a global leader in the subdivision field of medical equipment manufacturer - Uterine body: front and rear etc gynaecology radius, vertical radius, horizontal B mode radius - Uterine: long diameter, thick - Endar thickness diameter, wide diameter, intimal urology thickness, uterine body volume, B mode uterine diameter line - Bladder: long diameter, wide - Cervical cervix: long diameter, diameter, thick diameter, volume, thick diameter, wide diameter urine output - Uterine body / cervix: uterine - Kidney: long diameter, wide body, cervix, uterine body / cervix diameter, thick diameter, volume, - Left ovary: long diameter, thick cortical thickness diameter, - Prostate: Long diameter, wide wide diameter, and volume diameter, thick diameter, volume - Right ovary: long diameter, - Seminal vesicles: Long diameter, thick diameter, wide diameter, wide diameter, thick diameter volume - Bladder: Long diameter, wide - Dominant follicles: right diameter, thick diameter, volume, follicle diameter, right urine long output of follicle wide diameter, left follicle before/after urination long diameter, left follicle wide Doppler mode diameter - abdominal aorta Version: 1.0 2023-03 26 bladder M30 Technical Specifications To be a global leader in the subdivision field of medical equipment manufacturer - Principal renal artery Lung (B-line interval, pleural line -segmental artery thickness) - interlobular artery Doppler mode - arteriae arcuata - arteriae thyreoidea superior - renal vein - arteriae thyreoidea inferior Small organ Orthopaedic surgery B mode -Hip joint (hip joint, hip joint α , -Thyroid (L diameter, D diameter, hip joint β, hip joint Graf) D -d/D diameter, thickness, volume, thyroid isthmus mass 1~3 7 Storage and management distance 1/2/3) (built-in workstation) - Testis (L diameter, D diameter, D diameter, volume, testicle lump 7.1 Storage 1~3 distance 1/2/3) Storage capacity: 500GB - Epididymis (Long diameter, Support for patient information thick diameter, wide diameter) query / acquisition (name, ID, - capsule wall start date, End date) - Breast mass 1~10 (long Review and analysis of current diameter, thick diameter, wide examinations diameter, nipple mass and historical 1~10 examinations distance, skin mass 1~10 Support for new check, delete distance,) check, export check, and import Version: 1.0 2023-03 27 M30 Technical Specifications To be a global leader in the subdivision field of medical equipment manufacturer check - Shows multiple births Supports measurement on stored - Display analysis images -developmental curve Export image / movie formats: - Comparison chart Origin、JPG、DCM、BMP、TIFF、 Report preview supports enlarging, RAW 8bit、AVI shrinking, and adjustable paper Support for backup of patient data size to the USB device, DVD disc Reports can be exported in PDF format 7.2 Report Specific reports for 8 Connectivity each application area The report supports Support network connection multiple Support for D ICOM 3.0 images 9 Probe The latest value, average value, maximum value, minimum value Convex probe 3C5PD can be selected, and the value - Applications: ABD, OB, GYN, can be edited PedABD, The report display item is optional Urology,Pelvic Floor,Lung - Display measurement -Bandwidth:1.0-7.5MHz - Display comments - Number of Elements:128 - Display images (1/ line, 2/ line) Version: 1.0 2023-03 28 M30 Technical Specifications To be a global leader in the subdivision field of medical equipment manufacturer -Scan Range:32°-72° 6.0-9.5MHz, 8.5- 15.0MHz -Extended Imaging:82° - Harmonic frequency: H8.0MHz, -Radius of curvature:50mm H9.4MHz, H10.8MHz, H12.2MHz - - Depth range: 20-280mm Basic frequency:1.0-3.0MHz, 2.6-4.5MHz, 4.2- 7.5MHz - Harmonic Phased array probe 3P2PA frequency: - Applications: Adult Cardiac, Ped H3.4MHz, H4.0MHz,H 5.0MHz,H Cardiac, TCI, ABD 6.4MHz -Bandwidth:1.0-6.5MHz - Depth range: 40~420mm - Number of Elements: 64 Linear array probe 7L4PD -Scan Range:39°-90° - Applications: Carotid, Thyroid, - Basic frequency: 1.0-2.6MHz, Nerve, 2.4-3.8MHz, 3.5-6.5MHz Superficial, MSK, PedABD, - Harmonic frequency: H3.0MHz, Orthopedic, H4.0MHz, H5.0MHz,H 6.0MHz Vascular ,Testicle,Lung - Depth range: 30~320mm -Bandwidth:4.2-15.0MHz Volume probe 4V4CDS - Number of Elements: 128 - Applications: ABD, OB, GYN -Scan Range:17-38mm -Bandwidth:1.6-8.0MHz -Extended Imaging:20° - Number of Elements: 128 - Basic frequency: 4.2-6.3MHz, -Scan Range:30°-67° Version: 1.0 2023-03 29 M30 Technical Specifications To be a global leader in the subdivision field of medical equipment manufacturer -Extended Imaging:77° - Depth range: 20~280mm -Basic frequency : 1.6-3.0MHz, Micro-convex Probe 6C1PD 2.8-4.5MHz, 4.2-8.0MHz -Harmonic - Applications: Ped ABD, Ped frequency : Cardiac, TCI H5.0MHz,H 6.4MHz, H7.2MHz, -Bandwidth:3.5-12.0MHz H8.0MHz - Number of Elements: 128 - Depth range: 40~420mm - Basic frequency: 3.5-6.3MHz, Trans-vaginal probe 6E1PD - Applications: 6.0-7.5MHz, OB/GYN, 6.8-12.0MHz Prostate,Pelvic Floor -Harmonic frequency : H6.4MHz, -Bandwidth:2.5-13.0MHz H7.2MHz, - Number of Elements: 128 H10.0MHz H8.0MHz, - Depth range: 20~280mm -Scan Range:67°-148° -Extended Imaging:158° 10 System input and output -Radius of curvated:10mm USB 3.0 port: 1 -Basic frequency : 2.5-5.5MHz, USB 2.0 ports: 2 5.2-7.5MHz, HDMI port: 1 6.8-13.0MHz Video port: 1 - Harmonics frequency: S-Video port: one port H6.4MHz,H 7.2MHz, H8.0MHz, Printer remote control interface V10.0MHz Version: 1.0 2023-03 30 M30 Technical Specifications To be a global leader in the subdivision field of medical equipment manufacturer Ethernet interface - Time format (24-hour system, DC power port 12-hour system) Probe interface - Synchronization routine 11 Preset Patient information - 11.1 General settings Patient information field (patient ID, name, gender, age, Basic Settings operator, hospital, date of birth) Hospital information - Units of height and weight - Hospital name (metric and English) - Department name - Body surface area formula (East, - Telephone West) - Fax Settings - logo - Access at the end of the Area and language examination (scan, new patient, - Language (Chinese, English, work list) Spanish, French, Russian)time - Send after completion of zone inspection (yes/no automatically - Date and time send patient data to DICOM - Date format (yyyy-MM-dd, server) MM-dd-yyyy, dd-MM-yyyy) System sleep - Time Zone - Enable Screensaver (wait - Current time Version: 1.0 2023-03 31 M30 Technical Specifications To be a global leader in the subdivision field of medical equipment manufacturer 1/10/30/60 minutes) measurement, calipers) - On standby (wait 1/10/30/60 - Deflection (C&PW, C/PW, auto minutes) flip) - Preview - Horizontal ruler Image - Center line Image storage - - Movie storage length display Panoramic imaging scale Application - cardiac cycle - Image size (image area, standard Measuring scale area) - Cursor type (number, symbol) - Video output (PAL, NTSC) - Cursor size (large, medium, Set default values small) - Probe (select default probe model) - Color (active) (Green, yellow, red, Forward storage white) - Time (1-120 seconds) - - Cardiac cycle (1-120 cycles) (Green, yellow, red, White) Backward storage - Result size (large, medium, - Time (1-480 seconds) small) - Cardiac cycle (1-390 cycle) - Cardiac cycle (1-8) Color (intangible heritage) Image Settings - Delete measurement results -TI type (TIB, TIC, TIS) when deleting ruler (yes/No) - Frozen state (movie playback, Comment Version: 1.0 2023-03 32 M30 Technical Specifications To be a global leader in the subdivision field of medical equipment manufacturer - Font size (large, medium, small) - Length of ulna (Jeanty) - Arrow size (large, medium, - Humerus length (Jeanty, ASUM) small) - Chest diameter (Hansmann) - Automatically clear comments - Torso Cross (Osaka) when defrosting images, probes - Abdominal Transverse Diameter or checking mode switch (yes/no) (CFEF) - Automatically clear the position -occipito-frontal map when thawing the image (Hansmann, Nicolaides, ASUM) (yes/No) - Femur length (Hadlock, Tokyo, follicle Merz, Hansmann, Warda, Chitty, - Calculation method (single path Osaka, Nicolaides, ASUM, Jeanty, method, double path method, Hohler, China) three path method) - Obstetrics Abdominal diameter circumference (Hadlock, Jeanty, Merz, Chitty, Fetal gestational age formula Nicolaides, - Mean diameter of gestational Hansmann) sac (Daya, Hellman) - Head circumference (Hadlock, - Outer eye distance (Jeanty) Jeanty, -Transverse diameter of ASUM, Hansmann, CFEF, ChittyPL, Chitty_Derived, Nicolaides, ASUM, cerebellar (Hill, Nicolaides) CFEF) - Collarbone length (Yarkoni) - Double top diameter (Hadlock, - Tibia length (Jeanty) Tokyo, Jeanty, Kurtz, Hansmann, Version: 1.0 2023-03 33 M30 Technical Specifications To be a global leader in the subdivision field of medical equipment manufacturer Merz, Rempen, ChittyOI, Osaka, -Shepard China, Nicolaides, ASUM) -Merz1 - diameter -Merz2 Robinson, -Hansmann (BPD, THD) Head and hip (Hadlock, Tokyo, Rempen, Hansmann, ASUM, -Tokyo Jeanty, Nelson, China, -Osaka (FL, BPD, FTA) RobinsonBMUS) - Gestational (Rempen, -Campbell sac Tokyo, diameter - Tyre weight display units (metric, Hansmann, imperial, metric and imperial) China) One hundred points for fetal - fetal weight 2 (Hadlock, Tokyo) weight - fetal weight (Hadlock, Tokyo) - - Measurement results window Brenner, William) (indication of due date (yes/No), - gestational age of estimated fetal LMP&AUA/CUA, last menstrual weight in report (yes/No)) cycle) fetal weight/fetal weight 2 Formulas (NULL, Type Hadlock, (AUA/CUA, Fetal development curve formula -FL/HC (Hadlock) -Hadlock (AC, FL) -HC/AC (Campbell) -Hadlock (AC, FL, BPD) - Amniotic fluid index (Moore) -Hadlock (AC, FL, HC) - Umbilical artery RI (JSUM) -Hadlock (AC, FL, HC, BPD) - middle cerebral artery RI (JSUM) Version: 1.0 2023-03 34 M30 Technical Specifications To be a global leader in the subdivision field of medical equipment manufacturer - cisterns of posterior fossae Chitty, Jeanty, Osaka, Nicolaides, (Nicolaides) ASUM, CFEF) - Transverse cerebellar diameter (Hill, of - Goldstein, Abdominal circumference (Hadlock, Jeanty, Merz, Chitty, Nicolaides) Nicolaides, - Collarbone length (Yarkoni) Hansmann) - Fibula length (Merz, Jeanty) - Head circumference (Hadlock, - Radius length (Merz, Jeanty) Merz, Hansmann, Jeanty, CFEF, - Tibia length (Merz, Jeanty) ChittyPL, - Ulnar length (Merz, Jeanty) Nicolaides, ASUM) - Humerus length (ASUM, Merz, - Double top diameter (Hadlock, Jeanty) Tokyo, Jeanty, Kurtz, Sabbagha, - Chest diameter (Hansmann) Hansmann, - Torso Cross (Osaka) ChittyOI, - Abdominal transverse diameter ASUM, CFEF) (Merz, CFEF) - - Abdominal Thickness (Merz) (Hadlock, - Rempen, Hansmann, ASUM) occipito-frontal (Hansmann, Merz, diameter Nicolaides, - - Femur length (Hadlock, Tokyo, Hellman) Merz, Hansmann, O_Brien, Warda, - 35 and hip diameter Robinson, sac Tokyo, weight Rempen, Nicolaides, Tokyo, Gestational (Rempen, 2023-03 Merz, Osaka, Head fetal CFEF, Chitty_Derived, ASUM, Jeanty) Version: 1.0 ASUM, diameter Hansmann, 2 (Hadlock, M30 Technical Specifications To be a global leader in the subdivision field of medical equipment manufacturer Hansmann, Tokyo, Brenner, - Printing (analog image printing, William) - digital image printing) fetal weight (Hadlock, - Image mode (Enter tissue Tokyo, Brenner, Doppler mode, enter elastic Hansmann, William) - imaging mode, enter panoramic Supports importing new imaging mode, enter anatomical measurement formulas M imaging mode, enter dual - Trend chart (2*2, 1*2, 2*1, 1*1) real-time mode, enter four-image Custom key mode) - Trackball sensitivity (slow, - Others (QSave, Freeze/Thaw, medium, fast) - Key Ultrasound Assistant) authority brightness (0/1/2/3/4/5/6/6/7/8/9) - Administrator (View all patient - Key Volume (on/Off) data in the system, and can add Key type users, delete users, import data, - Keys (Save1, Save2, Q1, Q2, Q3, export data, delete data, edit data, Q4) store - Foot Switch (Reserved) software/firmware, etc.) Functional classification - Common user (view all patient - Output (save image to disk, data in the system, and can store movie forward, store movie import data, export data, delete backward) data, edit data, store data, etc.) Version: 1.0 2023-03 36 data, upgrade M30 Technical Specifications To be a global leader in the subdivision field of medical equipment manufacturer - Emergency users (view and mode store patient data) 11.3 application settings 11.2 Check preset Application preset - Probe: Select the probe type - Conventional measurement - Check mode library: Displays all - Added measurement items check modes supported by the - Remove measurement items current probe - Adjust - Selected Check mode: Displays measurement items the check mode added for the - Set current probe items the sequence default of measurement - Adds/removes check mode under Set the status after a single current probe measurement is completed - Add All/Move All check mode under - None (do not activate any current probe measurement - Sets the default inspection mode of completing the current probe measurement item) - New/delete custom check mode - Repeat (continue to perform the (customize current preset parameters and item the measurement current after name display under the corresponding completing probe) measurement) - Adjust the display position of check - Next (automatically activate the Version: 1.0 2023-03 37 the after current M30 Technical Specifications To be a global leader in the subdivision field of medical equipment manufacturer next measurement completing item the measurement after measurement item) current item, - Repeat (continue to perform the i.e. current measurement continuous measurement) completing Applied measurement measurement) - Added measurement items - Next (automatically activate the - Remove measurement items next - completing New (Open measurement customization) - Delete (Delete Advanced user-defined (Open Adjust the current item the after current item, i.e. continuous measurement) Custom application measurement/calculation items advanced Add research item measurement Settings) - measurement measurement measurement items) - the after sequence Edit of the application measurement items measurement package - Set default measurement items - Added measurement package - Set measurement attributes - Set the status after a single package measurement is completed - - None (do not activate any measurement packages measurement - Set the default measurement completing Version: 1.0 item the 2023-03 after current Remove Adjust the measurement the sequence of package 38 M30 Technical Specifications To be a global leader in the subdivision field of medical equipment manufacturer Report template - Brightness - Set the default report template - contrast ratio - Edit the report template - saturation 11.5 Network Preset - OK Local network - column - Wired network - Restore default - Wireless Network (Optional) DICOM service network 11.6 Printing the Preset Print service - Add service - Delete service - Rename service - Add printer - Default print service Printer attribute - Service type - Service name - Printer - Paper orientation - Paper size Picture parameter setting Version: 1.0 2023-03 39 M30 Technical Specifications
0
You can add this document to your study collection(s)
Sign in Available only to authorized usersYou can add this document to your saved list
Sign in Available only to authorized users(For complaints, use another form )