EMC Technologies Pty Ltd ABN 82 057 105 549 176 Harrick Road, Keilor Park Victoria Australia 3042 Ph: + 613 9365 1000 Fax: + 613 9331 7455 Email: sales@emctech.com.au EMC Test Report Report Number: M120643A Test Sample: DRMCC - Power transformer monitor and controller Model Number: C50 Series Tested For: Hydrix Services Pty Ltd Date of Issue: 26 May 2015 EMC Technologies Pty Ltd reports apply only to the specific samples tested under stated test conditions. It is the manufacturer’s responsibility to assure that additional production units of this model are manufactured with identical electrical and mechanical components. EMC Technologies Pty Ltd shall have no liability for any deductions, inferences or generalisations drawn by the client or others from EMC Technologies Pty Ltd issued reports. This report shall not be used to claim, constitute or imply product endorsement by EMC Technologies Pty Ltd. Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations and/or measurements included in this document are traceable to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the equivalence of testing, calibration and inspection reports. This document shall not be reproduced except in full. Report No. M120643A Page 2 of 59 Certificate of Compliance EMC Technologies Report No: M120643A Issue Date: 26 May 2015 Test Sample: Model Number: Serial Number: Manufacturer: DRMCC - Power transformer monitor and controller C50 Series 9CU#1 Dynamic Ratings Pty Ltd Tested for: Address: Hydrix Services Pty Ltd 1044A Dandenong Road, Carnegie VIC 3163, AUSTRALIA +61 (0)3 8573 5299 Greg Smart greg.smart@Hydrix Services Pty Ltd.com Phone: Contact: Email: Test Standards: *EN 60870-2-1: 1996 (IEC 60870-2-1: 1995) Section 5 Telecontrol equipment and systems, Part 2.1 Operating conditions – Power supply and electromagnetic compatibility Test Plan: DR C5 – EMC Test Plan Revision B, 25/07/2012 Result of Test: The DRMCC - Power transformer monitor and controller complied with the tests performed to the above standards as required in the test plan. Refer to Report M120643A for full details Test Dates: 3 and 4 July 2012 nd th 2 to 8 August 2012 th 15 November 2012 rd th Test Officers: Loïc Mazet Matt Grimwood Rob Weir Authorised Signature: Andrew Whiteford Manager (Melbourne) EMC Technologies Pty Ltd *IEC 61000-3-2 Current Harmonics and IEC 61000-3-3 Voltage Flicker tests referenced in EN 60870-2-1 are not within the current scope of NATA accreditation. Issued by EMC Technologies Pty. Ltd., 176 Harrick Road, Keilor Park, VIC, 3042, Australia. Phone: +61 3 9365 1000 Fax: +61 3 9331 7455 www.emctech.com.au Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations and/or measurements included in this document are traceable to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the equivalence of testing, calibration and inspection reports. This document shall not be reproduced, except in full. Report No. M120643A Page 3 of 59 Part 1 Electromagnetic Emissions Tests on the power transformer monitor and controller in accordance with section 5.4 of EN 60870-2-1 1.0 INTRODUCTION Electromagnetic Interference (EMI) tests were performed on the DRMCC - Power transformer monitor and controller, Model C50 Series in accordance with the emission requirements of section 5.4 of EN 60870-2-1. The details of the Equipment Under Test (EUT) and the test results are provided. The test sample was provided by the Client. All results herein apply only to the test sample. 1.1 Summary Conducted Emissions AC Mains DC Ports Telecommunication Ports Radiated Emissions **Current Harmonics **Voltage Fluctuations (Flicker) Complied with the limits by a margin of 4.1 dB Complied with the limits by a margin of 3.3 dB Complied with the limits by a margin of 5.7 dB Complied with the limit by a margin of 6.9 dB Complied, refer to Part 3 of this report Complied, refer to Part 4 of this report ** IEC 61000-3-2 Current Harmonics and IEC 61000-3-3 Voltage Flicker tests referenced in EN 60870-2-1 are not within the current scope of NATA accreditation. 2.0 GENERAL INFORMATION (Information supplied by the Client) 2.1 Test Sample: Model Name: Serial Number: Manufacturer: Highest operating Frequency: Power Ratings: DRMCC - Power transformer monitor and controller C50 Series 9CU#1 Dynamic Ratings Pty Ltd Tested With: Computer running emulator software Dynamic Ratings C50 Test System 400 MHz 240VAC, 200mA, 50Hz 220VDC Description The device monitors and controls various parameters on power transformers and interfaces with a computer system to analyse and record the data. Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations and/or measurements included in this document are traceable to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the equivalence of testing, calibration and inspection reports. This document shall not be reproduced, except in full. Report No. M120643A Page 4 of 59 2.2 Operating Conditions The computer running the emulation software was connected to the Ethernet port. The inputs and outputs were either connected to the C50 test system, loaded with a resistor or connected in a loop back configuration. Full details are provided in the customer test plan Appendix E 2.3 Modifications No modifications were performed. 3.0 REGULATIONS AND STANDARDS APPLIED EN 60870-2-1: 1996 (IEC 60870-2-1: 1995) Telecontrol equipment and systems, Part 2.1 Operating conditions – Power supply and electromagnetic compatibility CISPR 22: 2008 Ed 6 Information technology equipment – Radio disturbance characteristics – Limits and methods of measurement IEC 61000-3-2: 1994 Electromagnetic compatibility (EMC) – Part 3-2: Limits – Limits for harmonic current emissions (equipment input current ≤16 A per phase) IEC 61000-3-3: 1995 Electromagnetic compatibility (EMC) – Part 3-3: Limits – Limitations of voltage fluctuations and flicker in low voltage supply systems for equipment with rated current ≤16 A Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations and/or measurements included in this document are traceable to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the equivalence of testing, calibration and inspection reports. This document shall not be reproduced, except in full. Report No. M120643A Page 5 of 59 4.0 RESULTS 4.1 Test Results The EUT was tested as per the requirements of CISPR 22 and EMC Technologies test procedures TP Conducted Emissions and TP Radiated Emissions. 4.2 Conducted EMI Results 4.2.1 AC Mains Ports 240V/50Hz Frequency MHz Line 0.377 0.527 24.000 0.375 0.525 0.600 24.000 Active Active Active Neutral Neutral Neutral Neutral Measured QP Level dBµ µV 60.7 53.5 51.2 60.9 54.2 53.3 51.3 QP Limit dBµ µV ∆QP ±dB 79 73 73 79 73 73 73 -18.3 -19.5 -21.8 -18.1 -18.8 -19.7 -21.7 Measured AV Level dBµ µV 60.5 53.2 50.6 60.6 53.7 53.1 50.8 AV Limit dBµ µV 66 60 60 66 60 60 60 ∆AV ±dB -5.5 -6.8 -9.4 -5.4 -6.3 -6.9 -9.2 The worst case conducted EMI occurred at 0.375 MHz and complied with the quasi peak and average limits by margins of 18.1 dB and 5.4 dB respectively. Refer to Appendix B, graphs 1 & 2. 110V/60Hz Frequency MHz Line 0.375 0.264 0.526 0.599 24.000 0.374 0.264 0.526 24.000 Active Active Active Active Active Neutral Neutral Neutral Neutral Measured QP Level dBµ µV 61.8 63.6 55.7 54.0 52.2 61.8 63.1 56.2 52.1 QP Limit dBµ µV ∆QP ±dB 79 79 73 73 73 79 79 73 73 -17.2 -15.4 -17.3 -19.0 -20.8 -17.2 -15.9 -16.8 -20.9 Measured AV Level dBµ µV 61.8 60.7 54.1 53.9 51.5 61.9 60.8 54.4 51.5 AV Limit dBµ µV 66 66 60 60 60 66 66 60 60 ∆AV ±dB -4.2 -5.3 -5.9 -6.1 -8.5 -4.1 -5.2 -5.6 -8.5 The worst case conducted EMI occurred at 0.374 MHz and complied with the quasi peak and average limits by margins of 17.2 dB and 4.1 dB respectively. Refer to Appendix B, graphs 3 & 4. Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations and/or measurements included in this document are traceable to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the equivalence of testing, calibration and inspection reports. This document shall not be reproduced, except in full. Report No. M120643A Page 6 of 59 4.2.2 DC Ports 85VDC Frequency MHz Line 0.376 0.265 0.527 0.600 24.000 0.264 0.375 0.525 0.599 24.000 Positive Positive Positive Positive Positive Negative Negative Negative Negative Negative Measured QP Level dBµ µV 62.3 60.8 56.3 53.3 52.2 62.0 62.0 56.6 53.8 52.3 QP Limit dBµ µV ∆QP ±dB 79 79 73 73 73 79 79 73 73 73 -16.7 -18.2 -16.7 -19.7 -20.8 -17.0 -17.0 -16.4 -19.2 -20.7 Measured AV Level dBµ µV 62.5 61.1 54.2 53.1 51.6 62.3 62.1 54.9 53.7 51.7 AV Limit dBµ µV 66 66 60 60 60 66 66 60 60 60 ∆AV ±dB -3.5 -4.9 -5.8 -6.9 -8.4 -3.7 -3.9 -5.1 -6.3 -8.3 The worst case conducted EMI occurred at 0.376 MHz and complied with the quasi peak and average limits by margins of 16.7 dB and 3.5 dB respectively. Refer to Appendix B, graphs 5 & 6. 110VDC Frequency MHz Line 0.381 0.269 0.532 0.152 24.000 0.377 0.266 0.528 0.604 24.000 Positive Positive Positive Positive Positive Negative Negative Negative Negative Negative Measured QP Level dBµ µV 62.2 59.8 54.0 57.2 51.9 61.9 61.0 55.3 52.8 52.3 QP Limit dBµ µV ∆QP ±dB 79 79 73 79 73 79 79 73 73 73 -16.8 -19.2 -19.0 -21.8 -21.1 -17.1 -18.0 -17.7 -20.2 -20.7 Measured AV Level dBµ µV 62.3 60.1 53.3 57.5 51.4 62.1 61.2 54.1 52.6 51.7 AV Limit dBµ µV 66 66 60 66 60 66 66 60 60 60 ∆AV ±dB -3.7 -5.9 -6.7 -8.5 -8.6 -3.9 -4.8 -5.9 -7.4 -8.3 The worst case conducted EMI occurred at 0.381 MHz and complied with the quasi peak and average limits by margins of 16.8 dB and 3.7 dB respectively. Refer to Appendix B, graphs 7 & 8. 220VDC Frequency MHz Line 0.375 0.525 0.599 24.000 0.383 0.534 24.000 0.229 Positive Positive Positive Positive Negative Negative Negative Negative Measured QP Level dBµ µV 62.3 55.3 53.9 52.0 62.6 54.0 52.5 56.6 QP Limit dBµ µV ∆QP ±dB 79 73 73 73 79 73 73 79 -16.7 -17.7 -19.1 -21.0 -16.4 -19.0 -20.5 -22.4 Measured AV Level dBµ µV 62.5 54.7 53.7 51.4 62.7 53.7 51.9 56.9 AV Limit dBµ µV 66 60 60 60 66 60 60 66 ∆AV ±dB -3.5 -5.3 -6.3 -8.6 -3.3 -6.3 -8.1 -9.1 The worst case conducted EMI occurred at 0.383 MHz and complied with the quasi peak and average limits by margins of 16.4 dB and 3.3 dB respectively. Refer to Appendix B, graphs 9 & 10. Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations and/or measurements included in this document are traceable to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the equivalence of testing, calibration and inspection reports. This document shall not be reproduced, except in full. Report No. M120643A Page 7 of 59 4.2.3 Telecommunication Ports Emissions on the Ethernet line were measured using the current method. Frequency MHz Cable 24.000 Ethernet Measured QP Level dBµ µA 26.1 QP Limit dBµ µA ∆QP ±dB 43.0 -16.9 Measured AV Level dBµ µA 24.3 AV Limit dBµ µA 30.0 ∆AV ±dB -5.7 The worst case conducted EMI occurred at 24.00 MHz and complied with the quasi peak and average limits by margins of 16.9 dB and 5.7 dB respectively. Refer to Appendix B, graph 11. 4.3 Radiated EMI Results Testing was performed inside a compliant CISPR16-1-4 semi-anechoic chamber for a 2m x 2m x 2m test volume up to 18 GHz. Testing was performed at a distance of 10 metres for emissions 30 MHz to 1000 MHz and 3 metres for emissions 1000 MHz to 2000 MHz. Frequency MHz 38.18 36.00 250.02 Polarisation Vertical Vertical Horizontal Measured QP Level dBµ µV/m 33.1 33.1 37.9 QP LIMIT dBµ µV/m 40.0 40.0 47.0 ∆QP ±dB -6.9 -6.9 -9.1 The worst case radiated EMI occurred at 38.18 MHz and complied with the quasi peak limit by a margin of 6.9 dB. Refer to Appendix B, radiated emission graphs 1 to 6. 5.0 CONCLUSION The DRMCC - Power transformer monitor and controller, Model C50 Series tested on behalf of Hydrix Services Pty Ltd complied with emission requirements of section 5.4 of AS 60870-2-1. The compliance margins were as follows: Conducted Emissions AC Mains DC Ports Telecommunication Ports Radiated Emissions **Current Harmonics **Voltage Fluctuations (Flicker) Complied with the limits by a margin of 4.1 dB Complied with the limits by a margin of 3.3 dB Complied with the limits by a margin of 5.7 dB Complied with the limit by a margin of 6.9 dB Complied, refer to Part 3 of this report Complied, refer to Part 4 of this report ** IEC 61000-3-2 Current Harmonics and IEC 61000-3-3 Voltage Flicker tests referenced in EN 60870-2-1 are not within the current scope of NATA accreditation. Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations and/or measurements included in this document are traceable to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the equivalence of testing, calibration and inspection reports. This document shall not be reproduced, except in full. Report No. M120643A Page 8 of 59 6.0 MEASUREMENT UNCERTAINTIES EMC Technologies has evaluated the equipment and the methods used to perform the emissions testing. The estimated measurement uncertainties for emissions tests shown within this report are as follows: Conducted Emissions Mains Port 9kHz to 30 MHz ±3.2 dB Telecommunication Port (TLISN-Method) 150kHz to 30 MHz ±3.1 dB Telecommunication Port (Current Probe-Method) 150kHz to 30 MHz ±3.0 dB Radiated Emissions 9kHz to 30MHz 30MHz to 300MHz 300MHz to 1000MHz 1GHz to 18GHz ±4.1 dB ±5.1 dB ±4.7 dB ±4.6 dB The above expanded uncertainties are based on standard uncertainties multiplied by a coverage factor of k=2, providing a level of confidence of approximately 95%. Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations and/or measurements included in this document are traceable to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the equivalence of testing, calibration and inspection reports. This document shall not be reproduced, except in full. Report No. M120643A Page 9 of 59 Part 2 Electromagnetic Susceptibility Tests on the power transformer monitor and controller in accordance with section 5.2 of EN 60870-2-1 1.0 INTRODUCTION Electromagnetic Compatibility (EMC) tests were performed on the DRMCC - Power transformer monitor and controller, Model C50 Series in accordance with the requirements of section 5.2 of EN 60870-2-1. The test sample was provided by the Client. All results herein apply only to the test sample. 1.1 Summary of Results Electrostatic Discharges Radiated Fields Fast Transient Bursts Surges (1.2/50µs) Conducted Disturbances Magnetic Fields Voltage Dips Oscillatory waves Conducted common mode disturbances harmonics and interharmonics 2.0 ±8kV Contact, ±8kV Air Discharges 10 V/m, 1kHz 80% AM, 80-1000 MHz 10 V/m, 1kHz 80% AM, 1.4-2.6 GHz 4kV AC ports 4kV DC ports 4kV Signal lines 4kV AC ports 4kV DC Ports 2kV Signal lines 10 Vrms, 1kHz 80% AM, AC ports 10 Vrms, 1kHz 80% AM, signal lines 100 A/m continuous, 50 Hz 1000 A/m short, 50 Hz 100% dip 10ms (DC port) 100% dip 500ms (AC port) 40% dip 500ms, (AC port) 1kV/2kV AC ports 30V continuous 300V short Level 4 swept th 10% to 40 harmonic 2.5% interharmonics Complied Complied Complied Complied Complied Complied Complied Complied Complied Complied Complied Complied Complied Complied Complied Complied Complied Complied TEST SAMPLE DESCRIPTION and TEST SETUP DETAILS Refer to Part 1 Sections 2.0, 2.1 and the customer test plan Appendix E. 2.1 Operating Conditions Refer to Part 1 Section 2.2 and the customer test plan Appendix E. 2.2 Modifications No modifications were performed. Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations and/or measurements included in this document are traceable to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the equivalence of testing, calibration and inspection reports. This document shall not be reproduced, except in full. Report No. M120643A Page 10 of 59 3.0 REGULATIONS AND STANDARDS APPLIED IEC 61000-4-2: 1995 Electromagnetic Compatibility - Part 4-2: Testing and Measurement Techniques – Electrostatic Discharge immunity test. IEC 61000-4-3: 2006 Ed 3 Electromagnetic Compatibility - Part 4-3: Testing and Measurement Techniques – Radiated, radio-frequency electromagnetic field immunity test. IEC 61000-4-4: 1995 Electromagnetic Compatibility - Part 4-4: Testing and Measurement Techniques – Electrical fast transient/ burst immunity test. IEC 61000-4-5: 2005 Ed 2 and IEC 61000-4-5: 1995 Electromagnetic Compatibility - Part 4-5: Testing and Measurement Techniques – Surge immunity test IEC 61000-4-6: 2004 Ed 2.1 Electromagnetic Compatibility - Part 4-6: Testing and Measurement Techniques – Immunity to conducted disturbances induced by radio-frequency fields IEC 61000-4-8: 2001 Ed 1.1 Electromagnetic Compatibility - Part 4-8: Testing and Measurement Techniques – Powerfrequency magnetic field immunity test. IEC 61000-4-9: 1993 Electromagnetic Compatibility - Part 4-9: Testing and Measurement Techniques – Pulse magnetic field immunity test. IEC 61000-4-11: 1994 Electromagnetic Compatibility - Part 4-11: Testing and Measurement Techniques – Voltage dips, short interruptions and voltage variations immunity tests. IEC 61000-4-12: 1995 Electromagnetic Compatibility - Part 4-12: Testing and Measurement Techniques – Oscillatory waves immunity test. IEC 61000-4-16: 2002 Ed 1.1 Electromagnetic Compatibility - Part 4-8: Testing and Measurement Techniques – Test for immunity to conducted, common mode disturbances in the frequency range 0 Hz to 150 kHz. Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations and/or measurements included in this document are traceable to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the equivalence of testing, calibration and inspection reports. This document shall not be reproduced, except in full. Report No. M120643A Page 11 of 59 4.0 TEST REQUIREMENTS & PERFORMANCE CRITERIA 4.1 Test Sample Performance Criteria The following performance criteria were used to determine the pass/fail status for immunity tests: The equipment shall be considered to have passed the tests if – during, or as a result of, the tests – all of the following conditions are met for the equipment and the connected devices: • No hardware damage occurs; • No change in calibration beyond normal tolerance is caused by the test; • No loss or corruption of stored memory or data occurs, including active or stored settings; • System resets do not occur, and manual resetting is not required; • Established communications are not permanently lost; • If disrupted, established communications automatically recover within an acceptable time period; • Communication errors, if they occur, do not jeopardize the protective or control functions; • No changes in the states of the electrical, mechanical, or communication signal outputs occur. This includes alarms and status outputs; • No erroneous, permanent change of state of the visual, audible or message outputs occurs. Momentary changes in these outputs during the tests are permitted; • No error outside the normal tolerances for data communication signals (SCADA analogues) occurs. • The display may be affected but it must return to normal after the test. Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations and/or measurements included in this document are traceable to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the equivalence of testing, calibration and inspection reports. This document shall not be reproduced, except in full. Report No. M120643A Page 12 of 59 5.0 TEST RESULTS 5.1 Immunity to Electrostatic Discharge (IEC 61000-4-2) 5.1.1 Test Procedure This test was performed as per EMC Technologies test procedure TP801-2 and IEC 61000-4-2. A minimum of ten discharges were applied at each level. 5.1.2 Test Climatic Conditions Shielded Room Temperature: Relative Humidity: 5.1.3 19°C 59% Discharge Points Indirect contact discharges were applied to the horizontal coupling plane (HCP) at each side of the EUT. Indirect contact discharges were applied to the vertical coupling plane (VCP) with the VCP placed along the four sides of the EUT. Direct contact discharges were applied to the following points: • Centre of each side of EUT • Top centre (x3) • EUT rear (x3) • CPU Board – USB (x3), Ethernet (x1) • One screw on each module • Shell of display port Direct air discharges were applied to the following points: • All connectors and cables on all modules 5.1.4 Results Contact Discharges Horizontal Coupling Plane Horizontal Coupling Plane Vertical Coupling Plane Vertical Coupling Plane Direct Direct Results: Conclusion: Voltage ± 2kV ± 4kV ± 2kV ± 4kV ± 2kV ± 4kV Response No effect No effect No effect No effect No effect No effect The discharges caused horizontal lines to flash on display. The EUT complied with the performance criteria. Air Discharges Insulating Surfaces Insulating Surfaces Insulating Surfaces Results: Conclusion: Level 1 2 1 2 1 2 Level 1 2 3 Voltage ± 2kV ± 4kV ± 8kV Response No effect No effect No effect No effects were noted. The EUT complied with the performance criteria. Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations and/or measurements included in this document are traceable to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the equivalence of testing, calibration and inspection reports. This document shall not be reproduced, except in full. Report No. M120643A Page 13 of 59 5.2 Immunity to Radiated electromagnetic fields (IEC 61000-4-3) 5.2.1 Test Procedure This test was performed as per EMC Technologies test procedure TP1000-4-3 and IEC 61000-4-3. The radiating antenna was positioned at a distance of 3m from the EUT. The dwell time at each frequency was 3 seconds with a frequency step rate of 1%. All four sides of the EUT were directly exposed to the transmitting antenna. 5.2.2 Test Climatic Conditions Shielded Room Temperature: Relative Humidity: 5.2.3 20°C 60% Results Field Level 10V/m 10V/m 10V/m 10V/m 10V/m 10V/m 10V/m 10V/m 10V/m 10V/m 10V/m 10V/m 10V/m 10V/m 10V/m 10V/m Side Polarisation Modulation Frequency Band Response Front Front LHS LHS RHS RHS Rear Rear Front Front LHS LHS RHS RHS Rear Rear Vertical Horizontal Vertical Horizontal Vertical Horizontal Vertical Horizontal Vertical Horizontal Vertical Horizontal Vertical Horizontal Vertical Horizontal 1 kHz 80% AM 1 kHz 80% AM 1 kHz 80% AM 1 kHz 80% AM 1 kHz 80% AM 1 kHz 80% AM 1 kHz 80% AM 1 kHz 80% AM 1 kHz 80% AM 1 kHz 80% AM 1 kHz 80% AM 1 kHz 80% AM 1 kHz 80% AM 1 kHz 80% AM 1 kHz 80% AM 1 kHz 80% AM 80-1000 MHz 80-1000 MHz 80-1000 MHz 80-1000 MHz 80-1000 MHz 80-1000 MHz 80-1000 MHz 80-1000 MHz 1400-2600 MHz 1400-2600 MHz 1400-2600 MHz 1400-2600 MHz 1400-2600 MHz 1400-2600 MHz 1400-2600 MHz 1400-2600 MHz *Code 1 *Code 1 *Code 1 *Code 1 *Code 1 *Code 1 *Code 1 *Code 3 *Code 2 *Code 2 *Code 2 *Code 2 *Code 2 *Code 2 *Code 2 *Code 2 Response Codes: *Code 1: At 80-93 MHz (Vertical) and 81-86 MHz (horizontal), lines appear on LCD however EUT fully self-recovers at completion of test *Code 2: Lighting spot noted on LCD across the frequency range 80-1000 MHz *Code 3: At 109-115 MHz & 125-134 MHz, horizontal lines noted on. Results: Conclusion: Effects were noted (refer to Response Codes 1-3). These effects were within the permissible loss see clause 4.1. The EUT complied with the performance criteria. Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations and/or measurements included in this document are traceable to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the equivalence of testing, calibration and inspection reports. This document shall not be reproduced, except in full. Report No. M120643A Page 14 of 59 5.3 Immunity to Electrical Fast Transients (IEC 61000-4-4) 5.3.1 Test Procedure This test was performed as per EMC Technologies test procedure TP801-4 and IEC 61000-4-4. 5.3.2 Test Climatic Conditions Shielded Room Temperature: Relative Humidity: 5.3.3 18°C 49% Power Lines (AC ports) Injection Method Level Voltage Direct – active, neutral, earth Direct – active, neutral, earth Direct – active, neutral, earth Direct – active, neutral, earth Direct – active Direct – active Direct – active Direct – active Direct – neutral Direct – neutral Direct – neutral Direct – neutral Direct – earth Direct – earth Direct – earth Direct – earth 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 ± 0.5 kV ± 1.0 kV ± 2.0 kV ± 4.0 kV ± 0.5 kV ± 1.0 kV ± 2.0 kV ± 4.0 kV ± 0.5 kV ± 1.0 kV ± 2.0 kV ± 4.0 kV ± 0.5 kV ± 1.0 kV ± 2.0 kV ± 4.0 kV Repetition Rate 5 kHz 5 kHz 5 kHz 5 kHz 5 kHz 5 kHz 5 kHz 5 kHz 5 kHz 5 kHz 5 kHz 5 kHz 5 kHz 5 kHz 5 kHz 5 kHz Response *Code 1 *Code 1 *Code 1, Code 2 *Code 1, Code 2 *Code 1 *Code 1 *Code 1 *Code 1 *Code 1 *Code 1, Code 2 *Code 1 *Code 1 *Code 1 *Code 1 *Code 1, Code 2 *Code 1, Code 2 Response Codes: *Code 1: Horizontal lines appear on display *Code 2: Some data corrupted however data returned to normal after test. Results: Conclusion: 5.3.4 Effects were noted (refer to Response Codes 1 & 2). These effects were within the permissible loss se clause 4.1. The EUT complied with the performance criteria. Power Lines (DC ports) Injection Method Level Voltage Direct – positive, negative, earth Direct – positive, negative, earth Direct – positive, negative, earth Direct – positive, negative, earth 1 2 3 4 ± 0.5 kV ± 1.0 kV ± 2.0 kV ± 4.0 kV Repetition Rate 5 kHz 5 kHz 5 kHz 5 kHz Response *Code 1 *Code 1 *Code 1, Code 2 *Code 1, Code 2 Response Codes: *Code 1: Horizontal lines appear on display *Code 2: Some data corrupted however data returned to normal after test. Results: Conclusion: Effects were noted (refer to Response Codes 1 & 2). These effects were within the permissible loss. The EUT complied with the performance criteria. Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations and/or measurements included in this document are traceable to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the equivalence of testing, calibration and inspection reports. This document shall not be reproduced, except in full. Report No. M120643A Page 15 of 59 5.3.5 Signal Lines Testing was performed using direct injection. Injection Method Level Voltage direct – Ethernet cable direct – Ethernet cable direct – Ethernet cable direct – Ethernet cable 1 2 3 4 ± 0.25 kV ± 0.5 kV ± 1.0 kV ± 2.0 kV Repetition Rate 5 kHz 5 kHz 5 kHz 5 kHz Response *Code 1 *Code 1 *Code 1 *Code 1 Response Codes: *Code 1: Horizontal lines appear on display Results: Conclusion: Effects were noted (refer to Response Code 1). These effects were within the permissible loss see clause 4.1. The EUT complied with the performance criteria. 5.4 Immunity to Surges (IEC 61000-4-5) 5.4.1 Test Procedure This test was performed as per EMC Technologies test procedure TP1000-4-5 and IEC 61000-4-5. Ten (5 positive and 5 negative) impulses were applied. 5.4.2 Test Climatic Conditions Shielded Room Temperature: Relative Humidity: 5.4.3 18°C 49% AC Power Lines (1.2/50µs surges) Surges were applied at phase angles of 0, 90, 180 and 270 degrees with respect to the phase of the incoming mains. Power Line Level Voltage Common-mode (Active-Earth) Common-mode (Active-Earth) Common-mode (Active-Earth) Common-mode (Active-Earth) Common-mode (Neutral-Earth) Common-mode (Neutral-Earth) Common-mode (Neutral-Earth) Common-mode (Neutral-Earth) Differential-mode (Active-Neutral) Differential-mode (Active-Neutral) Differential-mode (Active-Neutral) Differential-mode (Active-Neutral) 1 2 3 4 1 2 3 4 1 2 3 4 ± 0.5 kV ± 1.0 kV ± 2.0 kV ± 4.0 kV ± 0.5 kV ± 1.0 kV ± 2.0 kV ± 4.0 kV ± 0.5 kV ± 1.0 kV ± 2.0 kV ± 4.0 kV Results: Conclusion: Repetition Rate 15s 30s 60s 60s 15s 30s 60s 60s 15s 30s 60s 60s Response No effect No effect No effect No effect No effect No effect No effect No effect No effect No effect No effect No effect No effects were noted. The EUT complied with the performance criteria. Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations and/or measurements included in this document are traceable to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the equivalence of testing, calibration and inspection reports. This document shall not be reproduced, except in full. Report No. M120643A Page 16 of 59 5.4.4 DC Lines (1.2/50µs surges) Power Line Common-mode (Positive-Earth) Common-mode (Positive-Earth) Common-mode (Positive-Earth) Common-mode (Positive-Earth) Common-mode (Negative-Earth) Common-mode (Negative-Earth) Common-mode (Negative-Earth) Common-mode (Negative-Earth) Differential-mode (Positive-Negative) Differential-mode (Positive-Negative) Differential-mode (Positive-Negative) Differential-mode (Positive-Negative) Results: Conclusion: 5.4.4 Level 1 2 3 4 1 2 3 4 1 2 3 4 Voltage ± 0.5 kV ± 1.0 kV ± 2.0 kV ± 4.0 kV ± 0.5 kV ± 1.0 kV ± 2.0 kV ± 4.0 kV ± 0.5 kV ± 1.0 kV ± 2.0 kV ± 4.0 kV Response No effect No effect No effect No effect No effect No effect No effect No effect No effect No effect No effect No effect No effects were noted. The EUT complied with the performance criteria. Signal Lines (1.2/50µs surges) Power Line Common-mode (Line-Earth) Common-mode (Line-Earth) Common-mode (Line-Earth) Results: Conclusion: Level 1 2 3 Voltage ± 0.5 kV ± 1.0 kV ± 2.0 kV Response No effect No effect No effect No effects were noted. The EUT complied with the performance criteria. 5.5 Immunity to Conducted Disturbances (IEC 61000-4-6) 5.5.1 Test Procedure This test was performed as per EMC Technologies test procedure TP1000-4-6 and IEC 61000-4-6. The dwell time at each frequency was 3 seconds with a frequency step rate of 1%. The disturbance was injected directly onto the power cables (AC and DC) using a CDN (coupling-decoupling network). Unshielded Ethernet cable was tested using the BCI (bulk current injection) method. 5.5.2 Test Climatic Conditions Shielded Room Temperature: Relative Humidity: 17°C 61% Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations and/or measurements included in this document are traceable to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the equivalence of testing, calibration and inspection reports. This document shall not be reproduced, except in full. Report No. M120643A Page 17 of 59 5.5.3 Results Cables Injection Method CDN-M3 CDN-M2 BCI AC Power DC Power Unshielded Voltage Modulation 10Vrms 10Vrms 10Vrms 1kHz 80% AM 1kHz 80% AM 1kHz 80% AM Frequency Band 0.15 - 80 MHz 0.15 - 80 MHz 0.15 - 80 MHz Response *Code 1 *Code 1 *Code 1 Response Codes: *Code 1: Horizontal lines appeared on LCD. Some measured values affected however all parameters return to normal at completion of test. Results: Conclusion: Effects were noted (refer to Response Code 1). These effects were within the permissible loss see clause 4.1. The EUT complied with the performance criteria. 5.6 Immunity to Continuous Power Frequency Magnetic Fields (IEC 61000-4-8) 5.6.1 Test Procedure This test was performed as per EMC Technologies test procedure TP1000-4-8 and IEC 61000-4-8. The EUT was tested using the immersion method; that is, placing it in the centre of a Helmholz induction coil. The EUT was exposed to continuous field levels for 5 minutes in the three orthogonal axes. 5.6.2 Test Climatic Conditions Shielded Room Temperature: Relative Humidity: 5.6.3 16°C 59% Results Axes Field Strength (A/m) 100 A/m 100 A/m 100 A/m X-Axis Y-Axis Z-Axis Results: Conclusion: Frequency Response 50 Hz 50 Hz 50 Hz No effect No effect No effect No effects were noted. The EUT complied with the performance criteria. 5.6 Immunity to Short Power Frequency Magnetic Fields (IEC 61000-4-8) 5.6.1 Test Procedure This test was performed as per EMC Technologies test procedure TP1000-4-8 and IEC 61000-4-8. The EUT was tested using the immersion method; that is, placing it in the centre of a Helmholz induction coil. The EUT was exposed to the field for 1 second in the three orthogonal axes. 5.6.2 Test Climatic Conditions Shielded Room Temperature: Relative Humidity: 16°C 59% Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations and/or measurements included in this document are traceable to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the equivalence of testing, calibration and inspection reports. This document shall not be reproduced, except in full. Report No. M120643A Page 18 of 59 5.6.3 Results Axes Field Strength (A/m) 1000 A/m 1000 A/m 1000 A/m X-Axis Y-Axis Z-Axis Results: Conclusion: Frequency Response 50 Hz 50 Hz 50 Hz No effect No effect No effect No effects were noted. The EUT complied with the performance criteria. 5.7 Immunity to Voltage Dips and Interruptions (IEC 61000-4-11) 5.7.1 Test Procedure This test was performed as per EMC Technologies test procedure TP1000-4-11 and IEC 61000-4-11. 5.7.2 Test Climatic Conditions Shielded Room Temperature: Relative Humidity: 5.7.3 18°C 49% Results 240V/50Hz The dips were applied at phase angles of 0, 45, 90, 135, 180, 225, 270 and 315 degrees with respect to the phase of the incoming mains (zero-crossings). Ut Test Freq. Angle Level (in % Ut) 240V 0 50 Hz All 240V 40 50 Hz All Ut is the rated voltage for the EUT. Results: Conclusion: Test Duration (ms) 500 500 No. of Tests 3 3 Interval (between test event) 10 seconds 10 seconds Response No effect No effect No effects were noted. The EUT complied with the performance criteria. 85VDC The dips were applied at a phase angle of 0 degrees with respect to the phase of the incoming mains (zero-crossings). Ut Test Freq. Angle Level (in % Ut) 85V 0 50 Hz 0 Ut is the rated voltage for the EUT. Results: Conclusion: Test Duration (ms) 10 No. of Tests 3 Interval (between test event) 10 seconds Response No effect No effects were noted. The EUT complied with the performance criteria. Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations and/or measurements included in this document are traceable to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the equivalence of testing, calibration and inspection reports. This document shall not be reproduced, except in full. Report No. M120643A Page 19 of 59 5.8 Immunity to Oscillatory waves (IEC 61000-4-12) 5.8.1 Test Procedure This test was performed as per IEC 61000-4-12. Ten (5 positive and 5 negative) impulses were applied at a repetition rate of one per second. The surge generator was configured to have a source impedance of 30 Ω. 5.8.2 Power Lines (AC ports) Surges were applied at phase angles of 0, 90, 180 and 270 degrees with respect to the phase of the incoming mains. Power Line Common-mode (Active-Earth) Common-mode (Active-Earth) Common-mode (Active-Earth) Common-mode (Neutral-Earth) Common-mode (Neutral-Earth) Common-mode (Neutral-Earth) Differential-mode (Active-Neutral) Differential-mode (Active-Neutral) Results: Conclusion: Level 1 2 3 1 2 3 1 2 Voltage ± 0.5 kV ± 1.0 kV ± 2.0 kV ± 0.5 kV ± 1.0 kV ± 2.0 kV ± 0.5 kV ± 1.0 kV Response No effect No effect No effect No effect No effect No effect No effect No effect No effects were noted. The EUT complied with the performance criteria. 5.9 Immunity to conducted common mode disturbances (IEC 61000-4-16) 5.9.1 Power frequency tests Line AC Mode Continuous 1 second Results: Conclusion: 5.9.2 Voltage 30V 300V 50Hz No effect No effect 60Hz No effect No effect 16.67 Hz No effect No effect DC No effect No effect No effects were noted. The EUT complied with the performance criteria. Swept frequency tests Line AC Frequency 15 Hz to 150 Hz 150 Hz to 1.5 kHz 1.5 kHz to 15 kHz 15 kHz to 150 kHz Results: Conclusion: Voltage 30 V to 3 V 3V 3 V to 30 V 30 V No effects were noted. The EUT complied with the performance criteria. Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations and/or measurements included in this document are traceable to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the equivalence of testing, calibration and inspection reports. This document shall not be reproduced, except in full. Report No. M120643A Page 20 of 59 5.10 Immunity to harmonics and interharmonics on the low voltage supply network 5.10.1 Harmonics th Sine-waves up to the 40 harmonic of the power frequency (50Hz) were superimposed onto the power supply having an amplitude of 10% of the supply voltage. Each frequency was dwelled on for 5 seconds. Results: Conclusion: No effects were noted. The EUT complied with the performance criteria. 5.10.2 Interharmonics Sine-waves covering the frequency range 16 Hz to 2000 Hz were superimposed onto the power supply having an amplitude of 2.5% of the supply voltage. The step size was 5Hz. Each frequency was dwelled on for 5 seconds. Results: Conclusion: 6.0 No effects were noted. The EUT complied with the performance criteria. CONCLUSION The DRMCC - Power transformer monitor and controller, Model C50 Series tested on behalf of Hydrix Services Pty Ltd complied with the immunity requirements of section 5.2 of EN 608702-1. Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations and/or measurements included in this document are traceable to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the equivalence of testing, calibration and inspection reports. This document shall not be reproduced, except in full. Report No. M120643A Page 21 of 59 Part 3 EMC Tests on the DRMCC - Power transformer monitor and controller in accordance with *IEC 61000-3-2 1.0 INTRODUCTION This part is intended to document the conformance of the DRMCC - Power transformer monitor and controller, Model C50 Series, with the Electromagnetic Interference requirements of IEC 61000-3-2. The standard deals with the limitation of harmonic currents injected into the public supply system. It specifies limits of harmonic components of the input current which may be produced by equipment tested under specified conditions. The details of the Equipment Under Test (EUT) and the test results are provided. The test sample was provided by the client. All results herein apply only to the test sample. 1.1 Summary *Current Harmonics Complied with the limits for a Class A device *Not within the current scope of NATA accreditation 2.0 TEST SAMPLE DESCRIPTION and TEST SETUP DETAILS Refer to Part 1 Section 2.0. 2.1 Operating Conditions Refer to Part 1, Section 2.1. 2.2 Modifications No modifications were performed. Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations and/or measurements included in this document are traceable to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the equivalence of testing, calibration and inspection reports. This document shall not be reproduced, except in full. Report No. M120643A Page 22 of 59 3.0 RESULTS 3.1 *IEC 61000-3-2: 1994 Requirements Clause 1 Clause 2 Clause 3 Clause 4 Clause 5 Clause 6 Clause 6.1 Clause 6.2 Scope Normative references Definitions General Classification of Equipment General requirements Control methods Harmonic current measurement Clause 6.3 Clause 7 Clause 7.1 Clause 7.2 Clause 7.3 Clause 7.4 Annex A Annex B Equipment in a rack or case Harmonic current limits Limits for Class A equipment Limits for Class B equipment Limits for Class C equipment Limits for Class D equipment Measurement circuit and supply source Requirements for measurement equipment Type test conditions Annex C Noted Noted Noted Noted Class A Noted Noted, all tests and equipment are in accordance with the requirements of this standard. Noted Tested to limits of table 1 Not applicable Not applicable Not applicable Noted Noted Noted *Not within the current scope of NATA accreditation 3.2 Test Results The flowchart in Clause 7 of the standard was adhered to, and the table below summarises that flowchart: Classification of equipment: EUT uses techniques not allowed by Clause 6.1: EUT is professional equipment: EUT belongs to exceptions of clause 7 or Annex C: Special test conditions apply to EUT: Test Duration: Class A No No No No, generic conditions were used 30 minutes The EUT was classified as a Class A device and tested to the limits given in table 1 of the standard. The unit complied with the requirements of the standard. Refer to Appendix C for further details. 4.0 CONCLUSION The DRMCC - Power transformer monitor and controller, Model C50 Series, tested on behalf of Hydrix Services Pty Ltd, complied with the requirements of IEC 61000-3-2. Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations and/or measurements included in this document are traceable to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the equivalence of testing, calibration and inspection reports. This document shall not be reproduced, except in full. Report No. M120643A Page 23 of 59 Part 4 EMC Tests on the DRMCC - Power transformer monitor and controller in accordance with *IEC 61000-3-3 1.0 INTRODUCTION This part is intended to document the conformance of the DRMCC - Power transformer monitor and controller, Model C50 Series, with the Electromagnetic Interference requirements of IEC 61000-3-3. The standard is concerned with the limitations of voltage fluctuations and flicker impressed on the public low-voltage system. It specifies limits of voltage changes which may be produced by an equipment tested under specified conditions and gives guidance on methods of assessment. The details of the Equipment Under Test (EUT) and the test results are provided. The test sample was provided by the client. All results herein apply only to the test sample. 1.1 Summary *Voltage Flicker Complied with the limits for Pst and Plt *Not within the current scope of NATA accreditation 2.0 TEST SAMPLE DESCRIPTION and TEST SETUP DETAILS Refer to Part 1 Section 2.0. 2.1 Operating Conditions Refer to Part 1 Section 2.1. 2.2 Modifications No modifications were performed. Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations and/or measurements included in this document are traceable to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the equivalence of testing, calibration and inspection reports. This document shall not be reproduced, except in full. Report No. M120643A Page 24 of 59 3.0 RESULTS 3.1 *IEC 61000-3-3: 1995 Requirements Clause 1 Clause 2 Clause 3 Clause 4 Scope Normative references Definitions Assessment of voltage changes, voltage fluctuations and flicker Clause 4.1 Assessment of relative voltage change, d Clause 4.2 Assessment of the short-term flicker value, Pst Clause 4.3 Assessment of long-term flicker value, Plt Clause 5 Limits Clause 6 Test conditions Annex A Annex B Application of limits and type test conditions for specific equipment Test conditions and procedures for measuring dmax voltage changes caused by manual switching Noted Noted Noted Noted Noted, the direct measurement method was used. Noted Tested to the limits specified in Clause 5 Noted, all tests and equipment are in accordance with the requirements of this standard. No specific test conditions apply for this product. Noted *Not within the current scope of NATA accreditation 3.2 Test Results The EUT was observed for three integration periods (30 minutes). The unit complied with the Pst and Plt requirements of the standard. Refer to Appendix D for further details. 4.0 CONCLUSION The DRMCC - Power transformer monitor and controller, Model C50 Series, tested on behalf of Hydrix Services Pty Ltd, complied with the requirements of IEC 61000-3-3. Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations and/or measurements included in this document are traceable to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the equivalence of testing, calibration and inspection reports. This document shall not be reproduced, except in full. Report No. M120643A Page 25 of 59 APPENDIX A1 TEST SAMPLE PHOTOGRAPHS Conducted Emissions Test Setup Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations and/or measurements included in this document are traceable to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the equivalence of testing, calibration and inspection reports. This document shall not be reproduced, except in full. Report No. M120643A Page 26 of 59 APPENDIX A2 TEST SAMPLE PHOTOGRAPHS Radiated Emissions Test Setup (below 1 GHz) Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations and/or measurements included in this document are traceable to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the equivalence of testing, calibration and inspection reports. This document shall not be reproduced, except in full. Report No. M120643A Page 27 of 59 APPENDIX A3 TEST SAMPLE PHOTOGRAPHS Radiated Emissions Test Setup (above 1 GHz) Flicker and Harmonics Test Setup Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations and/or measurements included in this document are traceable to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the equivalence of testing, calibration and inspection reports. This document shall not be reproduced, except in full. Report No. M120643A Page 28 of 59 APPENDIX A4 TEST SAMPLE PHOTOGRAPHS Electrostatic Discharges Test Setup Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations and/or measurements included in this document are traceable to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the equivalence of testing, calibration and inspection reports. This document shall not be reproduced, except in full. Report No. M120643A Page 29 of 59 APPENDIX A5 TEST SAMPLE PHOTOGRAPHS Radiated Fields Test Setup (below 1 GHz) Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations and/or measurements included in this document are traceable to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the equivalence of testing, calibration and inspection reports. This document shall not be reproduced, except in full. Report No. M120643A Page 30 of 59 APPENDIX A6 TEST SAMPLE PHOTOGRAPHS Radiated Fields Test Setup (above 1 GHz) Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations and/or measurements included in this document are traceable to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the equivalence of testing, calibration and inspection reports. This document shall not be reproduced, except in full. Report No. M120643A Page 31 of 59 APPENDIX A7 TEST SAMPLE PHOTOGRAPHS Transients/ Surges/ Voltage Dips & Interruptions Test Setup Electrical Fast Transients Setup – signal lines Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations and/or measurements included in this document are traceable to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the equivalence of testing, calibration and inspection reports. This document shall not be reproduced, except in full. Report No. M120643A Page 32 of 59 APPENDIX A8 TEST SAMPLE PHOTOGRAPHS 10/700µs Surges Setup – Signal line Conducted Disturbance Test Setup Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations and/or measurements included in this document are traceable to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the equivalence of testing, calibration and inspection reports. This document shall not be reproduced, except in full. Report No. M120643A Page 33 of 59 APPENDIX A9 TEST SAMPLE PHOTOGRAPHS Magnetic Fields (Continuous Power Frequency) Test Setup Magnetic Fields (Short Power Frequency) Test Setup Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations and/or measurements included in this document are traceable to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the equivalence of testing, calibration and inspection reports. This document shall not be reproduced, except in full. Report No. M120643A Page 34 of 59 APPENDIX A10 TEST SAMPLE PHOTOGRAPHS Oscillatory Waves Test Setup Conducted common mode disturbances Test Setup Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations and/or measurements included in this document are traceable to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the equivalence of testing, calibration and inspection reports. This document shall not be reproduced, except in full. Report No. M120643A Page 35 of 59 APPENDIX B GRAPHS OF EMI MEASUREMENTS CONDUCTED EMI Graph 1: 240Vac/50Hz Active Line, 0.15 MHz - 30 MHz Graph 2: 240Vac/50Hz Neutral Line, 0.15 MHz - 30 MHz Graph 3: 110Vac/60Hz Active Line, 0.15 MHz - 30 MHz Graph 4: 110Vac/60Hz Neutral Line, 0.15 MHz - 30 MHz Graph 5: 85Vdc Active Line, 0.15 MHz - 30 MHz Graph 6: 85Vdc Neutral Line, 0.15 MHz - 30 MHz Graph 7: 110Vdc Active Line, 0.15 MHz - 30 MHz Graph 8: 110Vdc Neutral Line, 0.15 MHz - 30 MHz Graph 9: 220Vdc Active Line, 0.15 MHz - 30 MHz Graph 10: 220Vdc Neutral Line, 0.15 MHz - 30 MHz Graph 11: Ethernet 0.15 MHz - 30 MHz RADIATED EMI Graph 1: Vertical 30 MHz - 1000 MHz Graph 2: Horizontal 30 MHz - 1000 MHz Graph 3: Vertical Peak 1000 MHz - 2000 MHz Graph 4: Horizontal Peak 1000 MHz - 2000 MHz Graph 5: Vertical Average 1000 MHz - 2000 MHz Graph 6: Horizontal Average 1000 MHz - 2000 MHz Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations and/or measurements included in this document are traceable to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the equivalence of testing, calibration and inspection reports. This document shall not be reproduced, except in full. Report No. M120643A Page 36 of 59 CONDUCTED EMI Graph 1: 240Vac/50Hz Active Line, 0.15 MHz - 30 MHz QP Limit dBµ µV 79 73 73 79 73 79 73 73 73 73 73 73 73 73 79 Peak Frequency MHz Line 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 0.377 0.527 24 0.15 1.278 0.266 2.105 2.781 18 1.056 9.078 24.75 18.75 1.058 0.199 Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active QP Measured dBµ µV 60.7 53.5 51.2 58.7 47.9 59.1 44.1 44 47.5 43.8 42.6 46.2 46.2 44 57.3 ∆QP ±dB -18.3 -19.5 -21.8 -20.3 -25.1 -19.9 -28.9 -29 -25.5 -29.2 -30.4 -26.8 -26.8 -29 -21.7 Average Measured dBµ µV 60.5 53.2 50.6 54.7 46.8 50.9 44 43.7 43.2 42.7 42.5 41.8 41.2 38.8 38.2 AV Limit dBµ µV 66 60 60 66 60 66 60 60 60 60 60 60 60 60 66 ∆AV ±dB -5.5 -6.8 -9.4 -11.3 -13.2 -15.1 -16 -16.3 -16.8 -17.3 -17.5 -18.2 -18.8 -21.2 -27.8 Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations and/or measurements included in this document are traceable to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the equivalence of testing, calibration and inspection reports. This document shall not be reproduced, except in full. Report No. M120643A Page 37 of 59 CONDUCTED EMI Graph 2: 240Vac/50Hz Neutral Line, 0.15 MHz - 30 MHz QP Limit dBµ µV 79 73 73 73 73 73 73 73 73 73 73 73 79 79 Peak Frequency MHz Line 1 2 3 4 5 6 7 8 9 10 11 12 13 14 0.375 0.525 0.6 24.0 1.198 9.214 1.051 2.174 2.847 18.75 13.26 18.0 0.177 0.199 Neutral Neutral Neutral Neutral Neutral Neutral Neutral Neutral Neutral Neutral Neutral Neutral Neutral Neutral QP Measured dBµ µV 60.9 54.2 53.3 51.3 48.3 47.2 45.5 45.2 44.7 47.6 42.4 45.8 50.5 59.8 ∆QP ±dB -18.1 -18.8 -19.7 -21.7 -24.7 -25.8 -27.5 -27.8 -28.3 -25.4 -30.6 -27.2 -28.5 -19.2 Average Measured dBµ µV 60.6 53.7 53.1 50.8 47.8 47 44.8 44.6 43.8 42.7 42.1 41.9 38.9 30.7 AV Limit dBµ µV 66 60 60 60 60 60 60 60 60 60 60 60 66 66 ∆AV ±dB -5.4 -6.3 -6.9 -9.2 -12.2 -13 -15.2 -15.4 -16.2 -17.3 -17.9 -18.1 -27.1 -35.3 Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations and/or measurements included in this document are traceable to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the equivalence of testing, calibration and inspection reports. This document shall not be reproduced, except in full. Report No. M120643A Page 38 of 59 CONDUCTED EMI Graph 3: 110Vac/60Hz Active Line, 0.15 MHz - 30 MHz QP Limit dBµ µV 79 79 73 73 73 79 73 73 73 73 73 73 73 73 Peak Frequency MHz Line 1 2 3 4 5 6 7 8 9 10 11 12 13 14 0.375 0.264 0.526 0.599 24 0.154 1.052 1.053 1.574 2.771 2.246 8.985 18.19 27.75 Active Active Active Active Active Active Active Active Active Active Active Active Active Active QP Measured dBµ µV 61.8 63.6 55.7 54 52.2 53.4 50.3 50.6 45.7 44.6 44.6 42.6 45.1 43.3 ∆QP ±dB -17.2 -15.4 -17.3 -19 -20.8 -25.6 -22.7 -22.4 -27.3 -28.4 -28.4 -30.4 -27.9 -29.7 Average Measured dBµ µV 61.8 60.7 54.1 53.9 51.5 53.2 46.3 45.5 45.1 44.5 43.8 42.3 40.4 39.4 AV Limit dBµ µV 66 66 60 60 60 66 60 60 60 60 60 60 60 60 ∆AV ±dB -4.2 -5.3 -5.9 -6.1 -8.5 -12.8 -13.7 -14.5 -14.9 -15.5 -16.2 -17.7 -19.6 -20.6 Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations and/or measurements included in this document are traceable to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the equivalence of testing, calibration and inspection reports. This document shall not be reproduced, except in full. Report No. M120643A Page 39 of 59 CONDUCTED EMI Graph 4: 110Vac/60Hz Neutral Line, 0.15 MHz - 30 MHz QP Limit dBµ µV 79 79 73 73 73 73 73 73 79 73 Peak Frequency MHz Line 1 2 3 4 5 6 7 8 9 10 0.374 0.264 0.526 24 1.497 9.132 1.05 1.051 0.154 2.77 Neutral Neutral Neutral Neutral Neutral Neutral Neutral Neutral Neutral Neutral QP Measured dBµ µV 61.8 63.1 56.2 52.1 47.8 47.3 49.8 50 52 45 ∆QP ±dB -17.2 -15.9 -16.8 -20.9 -25.2 -25.7 -23.2 -23 -27 -28 Average Measured dBµ µV 61.9 60.8 54.4 51.5 47.4 47.2 46.8 46.3 51.6 45 AV Limit dBµ µV 66 66 60 60 60 60 60 60 66 60 ∆AV ±dB -4.1 -5.2 -5.6 -8.5 -12.6 -12.8 -13.2 -13.7 -14.4 -15 Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations and/or measurements included in this document are traceable to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the equivalence of testing, calibration and inspection reports. This document shall not be reproduced, except in full. Report No. M120643A Page 40 of 59 CONDUCTED EMI Graph 5: 85Vdc Positive Line, Peak Frequency MHz Line 1 2 3 4 5 6 7 8 9 10 11 12 0.376 0.265 0.527 0.6 24 0.154 1.052 1.051 2.774 18 2.249 8.843 Positive Positive Positive Positive Positive Positive Positive Positive Positive Positive Positive Positive 0.15 MHz - 30 MHz QP Measured dBµ µV 62.3 60.8 56.3 53.3 52.2 53.9 48.1 48 44.6 47.2 44.5 41.3 QP Limit dBµ µV 79 79 73 73 73 79 73 73 73 73 73 73 ∆QP ±dB -16.7 -18.2 -16.7 -19.7 -20.8 -25.1 -24.9 -25 -28.4 -25.8 -28.5 -31.7 Average Measured dBµ µV 62.5 61.1 54.2 53.1 51.6 54.1 47.8 47.7 44.4 43 42.5 41 AV Limit dBµ µV 66 66 60 60 60 66 60 60 60 60 60 60 ∆AV ±dB -3.5 -4.9 -5.8 -6.9 -8.4 -11.9 -12.2 -12.3 -15.6 -17 -17.5 -19 Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations and/or measurements included in this document are traceable to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the equivalence of testing, calibration and inspection reports. This document shall not be reproduced, except in full. Report No. M120643A Page 41 of 59 CONDUCTED EMI Graph 6: 85Vdc Negative Line, Peak Frequency MHz Line 1 2 3 4 5 6 7 8 9 10 0.264 0.375 0.525 0.599 24 1.05 1.051 0.154 8.985 2.772 Negative Negative Negative Negative Negative Negative Negative Negative Negative Negative 0.15 MHz - 30 MHz QP Measured dBµ µV 62 62 56.6 53.8 52.3 47.9 47.6 52 46.1 45 QP Limit dBµ µV 79 79 73 73 73 73 73 79 73 73 ∆QP ±dB -17 -17 -16.4 -19.2 -20.7 -25.1 -25.4 -27 -26.9 -28 Average Measured dBµ µV 62.3 62.1 54.9 53.7 51.7 47.5 47.2 52.2 45.6 44.7 AV Limit dBµ µV 66 66 60 60 60 60 60 66 60 60 ∆AV ±dB -3.7 -3.9 -5.1 -6.3 -8.3 -12.5 -12.8 -13.8 -14.4 -15.3 Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations and/or measurements included in this document are traceable to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the equivalence of testing, calibration and inspection reports. This document shall not be reproduced, except in full. Report No. M120643A Page 42 of 59 CONDUCTED EMI Graph 7: 110Vdc Positive Line, Peak Frequency MHz Line 1 2 3 4 5 6 7 8 9 10 11 12 0.381 0.269 0.532 0.152 24 1.136 1.063 0.986 1.741 2.496 9.064 18.57 Positive Positive Positive Positive Positive Positive Positive Positive Positive Positive Positive Positive 0.15 MHz - 30 MHz QP Measured dBµ µV 62.2 59.8 54 57.2 51.9 49 48.2 47.6 45.7 43.4 41.5 42.3 QP Limit dBµ µV 79 79 73 79 73 73 73 73 73 73 73 73 ∆QP ±dB -16.8 -19.2 -19 -21.8 -21.1 -24 -24.8 -25.4 -27.3 -29.6 -31.5 -30.7 Average Measured dBµ µV 62.3 60.1 53.3 57.5 51.4 49.1 47.8 47.1 44.6 41.8 41.4 36.2 AV Limit dBµ µV 66 66 60 66 60 60 60 60 60 60 60 60 ∆AV ±dB -3.7 -5.9 -6.7 -8.5 -8.6 -10.9 -12.2 -12.9 -15.4 -18.2 -18.6 -23.8 Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations and/or measurements included in this document are traceable to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the equivalence of testing, calibration and inspection reports. This document shall not be reproduced, except in full. Report No. M120643A Page 43 of 59 CONDUCTED EMI Graph 8: 110Vdc Negative Line, Peak Frequency MHz Line 1 2 3 4 5 6 7 8 9 10 11 12 0.377 0.266 0.528 0.604 24 1.13 1.057 0.154 9.108 2.637 1.733 18.75 Negative Negative Negative Negative Negative Negative Negative Negative Negative Negative Negative Negative 0.15 MHz - 30 MHz QP Measured dBµ µV 61.9 61 55.3 52.8 52.3 49.2 48.2 53.2 45.8 44.6 45.2 47.5 QP Limit dBµ µV 79 79 73 73 73 73 73 79 73 73 73 73 ∆QP ±dB -17.1 -18 -17.7 -20.2 -20.7 -23.8 -24.8 -25.8 -27.2 -28.4 -27.8 -25.5 Average Measured dBµ µV 62.1 61.2 54.1 52.6 51.7 49.3 47.7 53.4 44.9 44.1 44 42.1 AV Limit dBµ µV 66 66 60 60 60 60 60 66 60 60 60 60 ∆AV ±dB -3.9 -4.8 -5.9 -7.4 -8.3 -10.7 -12.3 -12.6 -15.1 -15.9 -16 -17.9 Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations and/or measurements included in this document are traceable to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the equivalence of testing, calibration and inspection reports. This document shall not be reproduced, except in full. Report No. M120643A Page 44 of 59 CONDUCTED EMI Graph 9: 220Vdc Positive Line, Peak Frequency MHz Line 1 2 3 4 5 6 7 8 9 10 0.375 0.525 0.599 24 1.123 0.154 1.05 2.621 8.989 18.56 Positive Positive Positive Positive Positive Positive Positive Positive Positive Positive 0.15 MHz - 30 MHz QP Measured dBµ µV 62.3 55.3 53.9 52 49.2 53.5 48.1 44.2 42.1 45.6 QP Limit dBµ µV 79 73 73 73 73 79 73 73 73 73 ∆QP ±dB -16.7 -17.7 -19.1 -21 -23.8 -25.5 -24.9 -28.8 -30.9 -27.4 Average Measured dBµ µV 62.5 54.7 53.7 51.4 49.2 53.7 47.6 43.3 42.1 39.6 AV Limit dBµ µV 66 60 60 60 60 66 60 60 60 60 ∆AV ±dB -3.5 -5.3 -6.3 -8.6 -10.8 -12.3 -12.4 -16.7 -17.9 -20.4 Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations and/or measurements included in this document are traceable to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the equivalence of testing, calibration and inspection reports. This document shall not be reproduced, except in full. Report No. M120643A Page 45 of 59 CONDUCTED EMI Graph 10: 220Vdc Negative Line, Peak Frequency MHz Line 1 2 3 4 5 6 7 8 9 10 11 0.383 0.534 24 0.229 1.067 1.065 0.154 9.102 2.658 1.67 18.37 Negative Negative Negative Negative Negative Negative Negative Negative Negative Negative Negative 0.15 MHz - 30 MHz QP Measured dBµ µV 62.6 54 52.5 56.6 49.3 49.3 54.7 46.5 45.2 45.4 43.9 QP Limit dBµ µV 79 73 73 79 73 73 79 73 73 73 73 ∆QP ±dB -16.4 -19 -20.5 -22.4 -23.7 -23.7 -24.3 -26.5 -27.8 -27.6 -29.1 Average Measured dBµ µV 62.7 53.7 51.9 56.9 49 49 55 45.7 45.2 44 39.5 AV Limit dBµ µV 66 60 60 66 60 60 66 60 60 60 60 ∆AV ±dB -3.3 -6.3 -8.1 -9.1 -11 -11 -11 -14.3 -14.8 -16 -20.5 Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations and/or measurements included in this document are traceable to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the equivalence of testing, calibration and inspection reports. This document shall not be reproduced, except in full. Report No. M120643A Page 46 of 59 CONDUCTED EMI Graph 11: Ethernet, 0.15 MHz - 30 MHz Peak Frequency MHz Line 1 2 3 4 5 6 24.00 0.775 24.75 3.583 0.621 1.181 Ethernet Ethernet Ethernet Ethernet Ethernet Ethernet QP Measured dBµ µA 26.1 21.4 20.6 16.3 17.4 16.1 QP Limit dBµ µA 43.0 43.0 43.0 43.0 43.0 43.0 ∆QP ±dB -16.9 -21.6 -22.4 -26.7 -25.6 -26.9 Average Measured dBµ µA 24.3 17.9 15.9 14.4 12.4 10.5 AV Limit dBµ µA 30.0 30.0 30.0 30.0 30.0 30.0 ∆AV ±dB -5.7 -12.1 -14.1 -15.6 -17.6 -19.5 Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations and/or measurements included in this document are traceable to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the equivalence of testing, calibration and inspection reports. This document shall not be reproduced, except in full. Report No. M120643A Page 47 of 59 RADIATED EMI Graph 1: Vertical Polarisation, 30 MHz - 1000 MHz Peak Frequency MHz Polarisation 1 2 3 4 5 6 7 8 38.18 36.00 225.01 77.86 143.40 216.00 250.00 408.00 Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Measured QP Level dBµ µV/m 33.1 33.1 28.3 27.3 26.1 25.3 30.6 30.1 QP Limit dBµ µV/m ∆QP ±dB 40.0 40.0 40.0 40.0 40.0 40.0 47.0 47.0 -6.9 -6.9 -11.7 -12.7 -13.9 -14.7 -16.4 -16.9 Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations and/or measurements included in this document are traceable to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the equivalence of testing, calibration and inspection reports. This document shall not be reproduced, except in full. Report No. M120643A Page 48 of 59 RADIATED EMI Graph 2: Horizontal Polarisation Peak Frequency MHz Polarisation 1 2 3 4 5 6 7 250.02 336.00 175.04 158.24 756.01 404.97 36.02 Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal 30 MHz - 1000 MHz Measured QP Level dBµ µV/m 37.9 36.3 27.2 26.6 31.7 29.5 21.1 QP Limit dBµ µV/m ∆QP ±dB 47.0 47.0 40.0 40.0 47.0 47.0 40.0 -9.1 -10.7 -12.8 -13.4 -15.3 -17.5 -18.9 Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations and/or measurements included in this document are traceable to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the equivalence of testing, calibration and inspection reports. This document shall not be reproduced, except in full. Report No. M120643A Page 49 of 59 RADIATED EMI Graph 3: Vertical Polarisation, Peak Detector 30 MHz - 1000 MHz No emissions measured within 10 dB of the limit. Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations and/or measurements included in this document are traceable to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the equivalence of testing, calibration and inspection reports. This document shall not be reproduced, except in full. Report No. M120643A Page 50 of 59 RADIATED EMI Graph 4: Horizontal Polarisation, Peak Detector 30 MHz - 1000 MHz No emissions measured within 10 dB of the limit. Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations and/or measurements included in this document are traceable to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the equivalence of testing, calibration and inspection reports. This document shall not be reproduced, except in full. Report No. M120643A Page 51 of 59 RADIATED EMI Graph 5: Vertical Polarisation, Average Detector Peak Frequency MHz Polarisation 1 1175.95 Vertical Measured QP Level dBµ µV/m 43.8 30 MHz - 1000 MHz QP Limit dBµ µV/m ∆QP ±dB 56.0 -12.2 Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations and/or measurements included in this document are traceable to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the equivalence of testing, calibration and inspection reports. This document shall not be reproduced, except in full. Report No. M120643A Page 52 of 59 RADIATED EMI Graph 6: Horizontal Polarisation, Peak Detector Peak Frequency MHz Polarisation 1 1343.88 Horizontal Measured QP Level dBµ µV/m 44.9 30 MHz - 1000 MHz QP Limit dBµ µV/m ∆QP ±dB 56.0 -11.1 Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations and/or measurements included in this document are traceable to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the equivalence of testing, calibration and inspection reports. This document shall not be reproduced, except in full. Report No. M120643A Page 53 of 59 APPENDIX C1 *IEC 61000-3-2 Current Harmonics Test Results *Not within the scope of NATA accreditation Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations and/or measurements included in this document are traceable to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the equivalence of testing, calibration and inspection reports. This document shall not be reproduced, except in full. Report No. M120643A Page 54 of 59 APPENDIX C2 *IEC 61000-3-2 Current Harmonics Test Results *Not within the scope of NATA accreditation Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations and/or measurements included in this document are traceable to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the equivalence of testing, calibration and inspection reports. This document shall not be reproduced, except in full. Report No. M120643A Page 55 of 59 APPENDIX C3 *IEC 61000-3-2 Current Harmonics Test Results *Not within the scope of NATA accreditation Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations and/or measurements included in this document are traceable to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the equivalence of testing, calibration and inspection reports. This document shall not be reproduced, except in full. Report No. M120643A Page 56 of 59 APPENDIX C4 *IEC 61000-3-2 Current Harmonics Test Results *Not within the scope of NATA accreditation Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations and/or measurements included in this document are traceable to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the equivalence of testing, calibration and inspection reports. This document shall not be reproduced, except in full. Report No. M120643A Page 57 of 59 APPENDIX D1 *IEC 61000-3-3 Voltage Flicker Test Results *Not within the scope of NATA accreditation Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations and/or measurements included in this document are traceable to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the equivalence of testing, calibration and inspection reports. This document shall not be reproduced, except in full. Report No. M120643A Page 58 of 59 APPENDIX D2 *IEC 61000-3-3 Voltage Flicker Test Results *Not within the scope of NATA accreditation Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations and/or measurements included in this document are traceable to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the equivalence of testing, calibration and inspection reports. This document shall not be reproduced, except in full. Report No. M120643A Page 59 of 59 APPENDIX E Customer Test Plan Refer DR C5 – EMC Test Plan, Rev 1.0, 27/11/12 Accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations and/or measurements included in this document are traceable to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the equivalence of testing, calibration and inspection reports. This document shall not be reproduced, except in full.
0
You can add this document to your study collection(s)
Sign in Available only to authorized usersYou can add this document to your saved list
Sign in Available only to authorized users(For complaints, use another form )