ACUSON X300 Adjustment System 15 Inch Monitor Adjustment This document is valid for: ACUSON X300, SONOVISTA X300, ACUSON X300 premium edition (PE) Document Version / Disclaimer / Copyright 2 Document Version Siemens reserves the right to change its products and services at any time. In addition, manuals are subject to change without notice. The hardcopy documents cor‐ respond to the version at the time of system delivery and/or printout. Versions to hard‐ copy documentation are not automatically distributed. Please contact your local Siemens office to order a current version or refer to our website http://www.healthcare.siemens.com. Disclaimer Siemens provides this documentation “as is” without the assumption of any liability under any theory of law. The content described herein shall be used by qualified personnel who are employed by Siemens or one of its affiliates or who are otherwise authorized by Siemens or its affiliates to use such documents. Assemblers and other persons who are not employed by or otherwise directly affiliated with or authorized by Siemens or one of its affiliates are not entitled to use this documen‐ tation without prior written authority. Copyright “© Siemens, 2011” refers to the copyright of a Siemens entity such as: Siemens Healthcare GmbH - Germany Siemens Aktiengesellschaft - Germany Siemens Shenzhen Magnetic Resonance Ltd. - China Siemens Shanghai Medical Equipment Ltd. - China Siemens Medical Solutions USA Inc. - USA Siemens Healthcare Diagnostics Inc. - USA and/or Siemens Healthcare Diagnostics Products GmbH - Germany ACUSON X300 US11-101.842.01.01.02 08.11 Page 2 of 23 ultrasound © Siemens, 2011 Restricted Table of Contents 1 Appendix A: 15 Inch Monitor Adjustment 1.1 1.2 1.3 2 4 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Control Locations and Functions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Accessing the Monitor Control Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.3.1 To Adjust the Contrast and Brightness . . . . . . . . . . . . . . . . . . . . . 1.3.2 To Access the OSD Menu. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.3.3 To Adjust the Color Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.3.4 OSD Menu Key Lock and Unlock . . . . . . . . . . . . . . . . . . . . . . . . . . 1.3.5 Variable LAMP Intensity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.3.6 No SIgnal Message . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.3.7 Out of Range Message . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.3.8 SBC Error Message. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Changes to Previous Version 2.1 3 3 21 Changes to Previous Version . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . List of Hazard IDs © Siemens, 2011 Restricted US11-101.842.01.01.02 08.11 4 6 9 9 10 11 18 19 19 20 20 21 22 Page 3 of 23 ultrasound ACUSON X300 4 1 Appendix A: 15 Inch Monitor Adjustment 1.1 Overview The ACUSON X300TM and ACUSON X300TM PE ultrasound system includes a 15 inch, XGA color monitor with 1024 x 768 pixel. The following figure shows the monitor. Fig. 1: Monitor Operating at 47Hz to 63Hz frequency range, this non-interlaced monitor has four speak‐ ers - two mid/tweeters and two woofers for use with spectral Doppler. The monitor controls include: n Degauss n Brightness n Contrast n ACUSON X300 Test buttons (user serviceable adjustments are located inside the monitor). Refer to the FPD section in the Users Manual. US11-101.842.01.01.02 08.11 Page 4 of 23 ultrasound © Siemens, 2011 Restricted Appendix A: 15 Inch Monitor Adjustment 1 CAUTION The weight of the monitor (6.5 kg: 14.3 lb.) represent a lifting hazard. The use of improper lifting methods or lifting in an awkward manner can cause serious bodily injury. Use proper lifting methods. © Siemens, 2011 Restricted US11-101.842.01.01.02 08.11 Page 5 of 23 ultrasound ACUSON X300 5 6 1 Appendix A: 15 Inch Monitor Adjustment 1.2 Control Locations and Functions Fig. 2: Control Locations on the Front of the Monitor ACUSON X300 US11-101.842.01.01.02 08.11 Page 6 of 23 ultrasound © Siemens, 2011 Restricted Appendix A: 15 Inch Monitor Adjustment 1 Fig. 3: Connectors on the Rear of the Monitor Fig. 4: Control Locations on the bottom of the monitor © Siemens, 2011 Restricted US11-101.842.01.01.02 08.11 Page 7 of 23 ultrasound ACUSON X300 7 8 1 Appendix A: 15 Inch Monitor Adjustment Tab. 1 Control Locations and Functions Name Description Speaker (3W 8 ohm/ 5W 4ohm) X 2 Menu Button Set or Exit the OSD Menu Down Button Move or Adjust value in OSD Menu Microphone and MIC LED Microphone and Mic LED Light Button For light intensity of 4 steps as OFF, Low, Middle and Max Up Button Move or Adjust value of OSD Menu On / Off LED Normal: Green, No Signal: Amber Digital Input Connector 19P HDMI Input ACUSON X300 AC Input Connector AC100V -AC240V Light Hi-luminance LED US11-101.842.01.01.02 08.11 Page 8 of 23 ultrasound © Siemens, 2011 Restricted Appendix A: 15 Inch Monitor Adjustment 1 1.3 Accessing the Monitor Control Screen Use the following information to assist in accessing the Monitor Control Screen and set‐ tings. 1.3.1 To Adjust the Contrast and Brightness Do the following: n n Press MENU. The Contrast menu displays, ( Fig. 5 Page 9). Pressing the menu button will cycle through the different sub menus. Select the adjustment values with the Up and Down buttons. Fig. 5: Contrast and Brightness The FPD of ACUSON X300 PE systems has eight video modes which have different con‐ trast and brightness values. Those are controlled by ultrasound system input signal (refer to table below). Tab. 2 Mode 9300K (WW) Mode Gamma Contrast Brightness 0 X300 r2.0 default gam‐ ma 73 47 1 Linear FPD gamma 73 47 2 Linear FPD gamma 80 54 3 Linear FPD gamma 80 49 4 Linear FPD gamma 85 50 5 Linear FPD gamma 90 50 6 Linear FPD gamma 95 54 7 Linear FPD gamma 100 54 © Siemens, 2011 Restricted US11-101.842.01.01.02 08.11 Page 9 of 23 ultrasound ACUSON X300 9 10 1 Appendix A: 15 Inch Monitor Adjustment 1.3.2 Tab. 3 Mode 11000K (JPN) Mode Gamma Contrast Brightness 0 X300 r2.0 default gam‐ ma 82 72 1 Linear FPD gamma 82 72 2 X300 r2.0 default gam‐ ma 80 61 3 Linear FPD gamma 73 45 4 Linear FPD gamma 78 45 5 Linear FPD gamma 68 42 6 Linear FPD gamma 73 42 7 Linear FPD gamma 78 42 To Access the OSD Menu To access the OSD Menu, perform the following: n Press the MENU and UP button simultaneously, about 10 seconds, until the OSD Main Menu displays. Fig. 6: OSD Main Menu ACUSON X300 US11-101.842.01.01.02 08.11 Page 10 of 23 ultrasound © Siemens, 2011 Restricted Appendix A: 15 Inch Monitor Adjustment 1 1.3.3 To Adjust the Color Mode 1. Press Menu and UP simultaneously for about 10 seconds. Fig. 7: 2. The OSD picture displays. The sub-menu PICTURE is not activated. Fig. 8: © Siemens, 2011 Restricted US11-101.842.01.01.02 08.11 Page 11 of 23 ultrasound ACUSON X300 11 12 1 Appendix A: 15 Inch Monitor Adjustment 3. Press the Menu button once to activate the PICTURE sub menu. Fig. 9: ACUSON X300 US11-101.842.01.01.02 08.11 Page 12 of 23 ultrasound © Siemens, 2011 Restricted Appendix A: 15 Inch Monitor Adjustment 1 4. Press the UP button twice to reach the COLOR MODE. Fig. 10: 5. Go to the COLOR MODE menu. - © Siemens, 2011 Restricted Press MENU button once to go to the COLOR MODE sub menu. The sub OSD menu for 9300K, 11000K, SPARE and USER displays. US11-101.842.01.01.02 08.11 Page 13 of 23 ultrasound ACUSON X300 13 14 1 Appendix A: 15 Inch Monitor Adjustment Fig. 11: 6. Select Color Temperature with the Menu button. The default value is 9300K. - ACUSON X300 Select 9300K for WW setting Select 11000K for SONOVISTA setting US11-101.842.01.01.02 08.11 Page 14 of 23 ultrasound © Siemens, 2011 Restricted Appendix A: 15 Inch Monitor Adjustment 1 7. To change the Color Temperature: - Press Menu one time to change the Color Temp to 11000K. Each time the Menu button is pressed, the Color Temp changes. Fig. 12: © Siemens, 2011 Restricted US11-101.842.01.01.02 08.11 Page 15 of 23 ultrasound ACUSON X300 15 16 1 Appendix A: 15 Inch Monitor Adjustment 8. Select EXIT with the UP button, press MENU to exit from the menu. Fig. 13: ACUSON X300 US11-101.842.01.01.02 08.11 Page 16 of 23 ultrasound © Siemens, 2011 Restricted Appendix A: 15 Inch Monitor Adjustment 1 9. Press the Menu button after each EXIT. The OSD screen will disappear. Fig. 14: The OSD Menu will automatically clear if no button is pressed within 10 seconds. Adjust Menu is used only for the Analog RGB input signal. © Siemens, 2011 Restricted US11-101.842.01.01.02 08.11 Page 17 of 23 ultrasound ACUSON X300 17 18 1 Appendix A: 15 Inch Monitor Adjustment Fig. 15: Monitor Menu Tree 1.3.4 OSD Menu Key Lock and Unlock Do the following to Lock and Unlock the OSD Menu: ACUSON X300 US11-101.842.01.01.02 08.11 Page 18 of 23 ultrasound © Siemens, 2011 Restricted Appendix A: 15 Inch Monitor Adjustment 1 Locked OSD Menu key, 1. Press the up or down buttons approximately five seconds. The following message dis‐ plays indicating that the OSD menu key is locked. Fig. 16: OSD Menu Locked 2. Press the up or down buttons approximately five seconds. The following message dis‐ plays indicating that the OSD menu key is unlocked. Fig. 17: OSD Menu Unlocked 1.3.5 Variable LAMP Intensity Press the LIGHT button. The intensity of the LED is changed to On. Continue pressing the LIGHT button to cycle through the different levels of LED intensity, OFF, Low, Middle and Max. 1.3.6 No SIgnal Message If the following message displays indicating that there is no signal, check the signal cable. Fig. 18: No Signal Message © Siemens, 2011 Restricted US11-101.842.01.01.02 08.11 Page 19 of 23 ultrasound ACUSON X300 19 20 1 Appendix A: 15 Inch Monitor Adjustment 1.3.7 Out of Range Message The following message displays when the input frequency is out of range. Fig. 19: OSD Out of Range Message 1.3.8 SBC Error Message The following message displays when there is an SBC error: Fig. 20: ACUSON X300 US11-101.842.01.01.02 08.11 Page 20 of 23 ultrasound © Siemens, 2011 Restricted Changes to Previous Version 2 2.1 Changes to Previous Version Change(s) Description Initial Release N/A © Siemens, 2011 Restricted US11-101.842.01.01.02 08.11 Page 21 of 23 ultrasound ACUSON X300 21 22 3 List of Hazard IDs There are no Hazard IDs in this document. ACUSON X300 US11-101.842.01.01.02 08.11 Page 22 of 23 ultrasound © Siemens, 2011 Restricted - Restricted - All documents may only be used by authorized person‐ nel for rendering services on Sie‐ mens Healthcare Products. Any document in electronic form may be printed once. Copy and distribu‐ tion of electronic documents and hardcopies is prohibited. Offenders will be liable for damages. All other rights are reserved. healthcare.siemens.com/services Siemens Healthcare Headquarters Siemens Healthcare GmbH Henkestrasse 127 91052 Erlangen Germany Telephone: +49 9131 84-0 siemens.com/healthcare Print No.: US11-101.842.01.01.02 | Replaces: n.a. Doc. Gen. Date: 08.11 | Language: English © Siemens Healthcare GmbH, 2011 siemens.com/healthcare
0
You can add this document to your study collection(s)
Sign in Available only to authorized usersYou can add this document to your saved list
Sign in Available only to authorized users(For complaints, use another form )