North-South Commuter Railway Extension Project
CP N-05 : Building and Civil Engineering Work for Depot Building
Including Related Infrastructure and Track Work Ballast
(Contract No : NSCREX-03-N05)
INSPECTION CHECKLIST REPORT
Procedure for Treatment of Hangers and Supports for Architectural Suspended Ceiling and
MEPF Systems.
LOCATION:
LINE OR STRUCTURE:
REPORT NO:
DOCUMENT REF & REV NO:
NSCR-PSC-N05-MABDPT-PRO-QA-000016 Rev. A
POSCO E&C
ENGINEER
CONSTRUCTION
QC
DESCRIPTION
DATE:
IR REF. NO:
ITP NO:
REMARKS
1.0 Preliminaries /Approval
1.1. Ensure materials is approved
HP
HP
RI
HP
HP
RI
HP
HP
WP
3.1.Inspection for Severe Corrosion
- Inspect the threaded rods and runner for any
signs of deep pitting or extensive corrosion. If the
rods are severely compromised, they will need to
be replaced with new threaded rods.
HP
WP
WP
3.2. Surface Cleaning and Preparation
- Use a steel brush to remove loose rust and
scale from the threaded rods and runners. Scrub
vigorously along the entire length of the rod,
ensuring all the rust is brushed away
- For hard-to-reach areas or more stubborn
corrosion, use sandpaper (medium grit) to lightly
sand the surface, ensuring that the majority of the
corrosion is removed.
HP
WP
WP
3.3. Clean the Threaded Rods
- After removing rust, apply paint thinner to
remove any oils, grease, or remaining debris on
the rods. Use a clean cloth soaked in paint
thinner and wipe down the entire length of the
threaded rods.
- Ensure that no grease, oil, or other residues are
left, as they will hinder the adhesion of the primer
and paint.
HP
WP
WP
HP
WP
WP
HP
WP
HP
1.2. Ensure approved method statement
2.0 Preparation
2.1.Initial Inspection and Preparation
3.0. Execution and Implementation
3.4. Application of Paint
- Apply a coat of Chugoku Epicon Zinc Rich
Primer B-2. The primer will provide excellent
corrosion resistance and protect the steel from
future rusting.
- Use a paint roller or brush to apply the primer
evenly along the entire length of the rods. Ensure
the coating is uniform, with no missed areas.
- Apply the primer in two coats for optimal
protection. Allow the first coat to dry completely
before applying the second coat (typically, allow
30 minutes to 1 hour drying time between coats).
4.0 Final Acceptance
4.1. Final Acceptance
OTHER REMARKS
INITIALS REFERENCE BOX : (WRITE DOWN YOUR INITIALS AS SIGNED ABOVE AND NAME)
SIGNATURE
NAME
POSITION
DATE:
QC
LEGEN
FORM NO. CPN05-POSCO-QA-003
HP : HOLD POINT
WP : WITNESS POINT
ENGINEER
RI : RANDOM INSPECTION