Laser Transmission Systems Touch Probes Mida Laser P data sheet Software MIDA LASER P SYSTEM TECHNICAL DATA Main features ML75P ML105 - 105P Stand alone and modular Modular Collimated (only for modular type) Focused (for both types) Laser beam shape Almost rounded (4/3) Almost rounded (4/3) ≥ 50 μm (Pico Laser) ≤ 2 mm (Collimated) ≥ 100 μm (Focused) ≤ 2 mm (Collimated) Wave length 670 nm 670 nm (visible laser beam Class 2) (visible laser beam Class 2) < 1 mW < 1 mW Lateral, frontal and bottom / 136, 165, 215, 295 and 415 mm* / Space between shutters 32, 48, 98, 178 and 298 mm / Distance between modules ≤ 3 m (Collimated) ≤ 1.2 m (Focused) ≤ 12 m (Collimated) ≤ 3.6 m (Focused) Protection degree IP67 IP67 Repeatability error 2σ ≤ 0.2 μm Power emitted Fork connection position Fork outlet length for stand alone version for stand alone version for modular version (IEC 60529 standard) Cable connection length 10, 20 and 30 m (with or without 5 m protection) Cable connection types Electronic interface Tool & Process Monitoring Laser beam dimensions Toolsetting Arms Collimated Focused Laser beam types 2σ ≤ 1 μm depending on brackets and distance between modules 10, 20 and 30 m (with or without 5 m protection) Straight and 90° Straight and 90° External with microprocessor Integrated into receiver module (ML105) External with microprocessor (ML105P) (*) = it is foreseen the availability of special fork lengths of 600, 800 and 1000 mm MIDA LASER 75P DATA SHEET 1 Accessories Available types Dimensions and codes 161.8 138 Touch Probes 20 35T443001 5 Cod. 30 Mida Laser 75P Pico 35 60 32 6 22 33.7 65 80 Transmission Systems Laser 5.9 30 10 50 10 15.9 11.8 Mida Laser 75P Stand Alone frontal connector with or without extensions Software 10 20 Toolsetting Arms Ø5.3 n.4 through holes 60 58.5 33.6 83 4 15 30 35.9 48.8 49 23.5 B 22.5 22.5 L 165 165 165 215 215 215 295 295 295 415 415 415 B 52.2 52.2 52.2 77.5 77.5 77.5 117.5 117.5 117.5 177.5 177.5 177.5 X 48 48 48 98 98 98 178 178 178 298 298 298 58.5 X 6 Accessories 2 MIDA LASER 75P DATA SHEET L 104.5 + K K 29.35 32 + K E (asse di lavoro) 60 Tool & Process Monitoring 4 E 60 85.4 131 60 85.4 131 60 85.4 131 60 85.4 131 K 0 25.4 71 0 25.4 71 0 25.4 71 0 25.4 71 Code 35T0443128 35T0443126 35T0443127 35T0443138 35T0443136 35T0443137 35T0443148 35T0443146 35T0443147 35T0443158 35T0443156 35T0443157 B 58.5 K 0 25.4 71 0 25.4 71 0 25.4 71 0 25.4 71 Code 35T0443160 35T0443162 35T0443163 35T0443170 35T0443172 35T0443173 35T0443180 35T0443182 35T0443183 35T0443190 35T0443192 35T0443193 X 48 48 48 98 98 98 178 178 178 298 298 298 E 60 85.4 131 60 85.4 131 60 85.4 131 60 85.4 131 K 0 25.4 71 0 25.4 71 0 25.4 71 0 25.4 71 Code 35T0443120 35T0443122 35T0443123 35T0443130 35T0443132 35T0443133 35T0443140 35T0443142 35T0443143 35T0443150 35T0443152 35T0443153 Mida Laser 75P Stand Alone bottom connector with or without extension L 165 165 165 215 215 215 295 295 295 415 415 415 60 22.5 30 15 B 22.5 X 58.5 B 52.5 52.5 52.5 77.5 77.5 77.5 117.5 117.5 117.5 177.5 177.5 177.5 Tool & Process Monitoring 152.3 + K K 49 Accessories 83 47.8 34.9 4 32.5 29.4 6 32 + K E (asse di lavoro) 60 Ø10 58.5 20 L Ø5.3 n.4 through holes 10 4 Laser 104.5 + K 29.4 14.5 6 32 + K 19 K E (asse di lavoro) 60 Ø10 22.5 E 60 85.4 131 60 85.4 131 60 85.4 131 60 85.4 131 Software X 22.5 X 48 48 48 98 98 98 178 178 178 298 298 298 Toolsetting Arms 60 76.5 66.5 B 52.2 52.2 52.2 77.5 77.5 77.5 117.5 117.5 117.5 177.5 177.5 177.5 Touch Probes 15 30 L Ø5.3 n.4 through holes 20 10 24 L 165 165 165 215 215 215 295 295 295 415 415 415 Transmission Systems Mida Laser 75P Stand Alone lateral connector with or without extension 23.5 MIDA LASER 75P DATA SHEET 3 Mida Laser 75P Modular 5.5 13 22 8.5 Touch Probes 70.4 40 15 Code RX 34T0443550 TX (collimated) 34T0443050 TX (focused) on demand 75.8 116.9 R5 5.5 19 3.5 Ø9 16 9 26 58 86 Transmission Systems 10.4 40 20 9.8 61.5 Type Laser 30 30 7 9 48 50 12.5 10 35 10 11.5 R5 Toolsetting Arms 55 M5 n.4 through holes 20 20 Software Mida Laser 105 - 105P Modular 88.5 3.5 5.5 17.5 43 M5 n.4 through holes 12 85 105 88 Tool & Process Monitoring Accessories 24.5 45.5 17.5 66 4 MIDA LASER 75P DATA SHEET 6.2 Type Code RX 34T0437103 TX (collimated) 34T0437151 TX (focused) on demand Interface-PLC/CNC wiring diagram Photodiode Receiver Touch Probes Laser Emitter SHIELD Shutter (W) management DB15 MALE CONNECTOR SHIELD Blower kit for tool cleaning (X) YV1 DB9 FEMALE CONNECTOR COMMON IN 15 (ENABLE_DYN / MEMORY) IN1 9 (DYN DURATION 0) IN2 10 (DYN DURATION 1) IN3 11 (TRIGGER SELECTION) IN4 12 (LASER ENABLE) IN5 13 (POLARITY) IN6 14 (LASER_OK+) OUT1+ 3 PLC Dynamic Enable Trigger Selection Laser Enable Dynamic Polarity * Isolated I/O Tool Cleaner Laser OK 4 (LASER_OK-) OUT1(DYNAMIC+) OUT2+ CNC Laser RS-232 Serial Transmission Systems Air IN μC Unit * 5 Air Barrier Dynamic Output 6 (STATIC+) OUT3+ Static Output 8 (STATIC-) OUT3V+ 1 VDC V- 2 GND SHIELD PE * 7 Case Toolsetting Arms Isolated Power Supply Software (DYNAMIC-) OUT2- PE Option Accessories Tool & Process Monitoring Full installation needs: 1 skip input (a fast input would be suggested), 2 M-Codes (SET/RST) and at least 1 PLC INPUT (Laser OK) Special cycle can request additional input (Max. 2 more) and output (1 more) MIDA LASER 75P DATA SHEET 5 Integrated air filter group 86.6 Touch Probes 28.5 182.5 30 31.3 Ø7 70 Ø5.5 9 57 Transmission Systems Laser 302.7 Software 0Z2 ø6x1 C MPa Toolsetting Arms ø4x0,75 0.01 μm 0V2 0F1 A 0÷1 Mpa E in out ø6x1 B 0V3 A OV4 A A 0V1 Pmin= 0,1 MPa Pmax= 0,6 MPa P R IN 0Z5 out 5 μm 0F2 Tool & Process Monitoring (ISO 8573-1 /7.4.4 standard) Solid parts 40 μm Dew point 3 °C Oily part ≤ 5 mg/m³ Accessories Air consumption ≤ 200 l/min Power supply 24 Vdc with tool cleaning blower MIDA LASER 75P DATA SHEET 0Z3 D ø6x1 0Z4 6 R P ø6x1 in OUT EXH ø6x1 Input air quality R P 0Z1 A Shutter • 3 bar ≤ air pressure ≤ 6 bar • air consumption ≈ 0 • connector Ø4 mm B Barrier air • air pressure ≤ (shutter pressure -1.5 bar) • air consumption ≈ 100 l/min • connector Ø6 mm C Tool cleaning air jet • air consumption ≤ 70 l/min • connector Ø6 mm D Barrier air flow regulation E Tool cleaning air regulation Accuracy errors Accuracy error [mm] Pico 165 mm 215 mm 295 mm 415 mm Modular F = 500 mm Collimated Pico 165 mm 215 mm 295 mm 415 mm Modular F = 500 mm Collimated 0.060 0.080 0.100 0.150 0.300 0.009 0.011 0.014 0.021 0.043 0.500 1.500 0.060 0.080 0.100 0.150 0.300 0.071 0.214 0.014 0.019 0.024 0.036 0.072 0.500 1.500 0.121 0.362 Software Drill 90° edge Beam diameter [mm] Transmission Systems Drill 120° edge Fork dimension Laser Tool type Touch Probes ACCURACY ERROR DUE TO A DRILL CUTTING EDGE Accessories Error [mm] Tool & Process Monitoring Toolsetting Arms ACCURACY ERROR DUE TO A BALL NOSE TOOL RADIUS Ball radius [mm] MIDA LASER 75P DATA SHEET 7 ACCURACY ERROR DUE TO A SMALL BALL NOSE TOOL RADIUS (WITH PICO LASER) Transmission Systems Error [mm] Touch Probes Laser Ball radius [mm] Software Note: • red curve = detected values • blue curve = mathematical function to input into measuring cycles to compensate accuracy error Toolsetting Arms Tool & Process Monitoring Accessories For a full list of address locations, please consult the Marposs official website D6C05700G0 - Edition 09/2012 - Specifications are subject to modifications © Copyright 2012 MARPOSS S.p.A. (Italy) - All rights reserved. and Marposs product names/signs mentioned or shown herein are registered trademarks or trademarks of Marposs in MARPOSS, the United States and other countries. The rights, if any, of third parties on trademarks or registered trademarks mentioned in the present publication are acknowledged to the respective owners. www.marposs.com 8 Marposs has an integrated system to manage the Company quality, the environment and safety, attested by ISO 9001, ISO 14001 and OHSAS 18001 certifications. Marposs has further been qualified EAQF 94 and has obtained the Q1-Award. MIDA LASER 75P DATA SHEET Download the latest version of this document
0
You can add this document to your study collection(s)
Sign in Available only to authorized usersYou can add this document to your saved list
Sign in Available only to authorized users(For complaints, use another form )