Flexi Cabinet Outdoor (FCOB) Quick Guide This guide is a quick reference for the Flexi Cabinet Outdoor (FCOB) installation. The Flexi Cabinet Outdoor (FCOB) can be installed vertically (on walls, poles and floors) and horizontally (on floors). More detailed information on FCOB installation and cabling are described in the Installing Flexi Cabinet Outdoor (FCOB) DN09223971 document. Check the site 1 Contents of delivery Prepare the installation 2 Preparing the installation Lift the cabiinet Installation 3 Lifting the cabinet 4 Installing onto a wall onto a pole 5 Installing with FPKA onto a pole 6 Installing with FPKC 7 Installing vertically on a floor 8 Installing horizontally on a floor 9 Stacking FCOBs 3U casing 10 Installing on top of FCOB FCOB on 11 Installing top of 3U casing Modules installation Installing FYGG 12 inside of the FCOB 13 Installing FYGE inside of FCOB 14 Installing FSIH inside of FCOB 15 Installing AirScale SM Indoor inside of FCOB The information in this document applies solely to the hardware/software product (“Product”) specified herein, and only as specified herein. This document is intended for use by Nokia customers (“You”) only, and it may not be used except for the purposes defined in the agreement between You and Nokia (“Agreement”) under which this document is distributed. No part of this document may be used, copied, reproduced, modified or transmitted in any form or means without the prior written permission of Nokia. If you have not entered into an Agreement applicable to the Product, or if that Agreement has expired or has been terminated, You may not use this document in any manner and You are obliged to return it to Nokia and destroy or delete any copies thereof. The document has been prepared to be used by professional and properly trained personnel, and You assume full responsibility when using it. Nokia welcome Your comments as part of the process of continuous development and improvement of the documentation. This document and its contents are provided as a convenience to You. Any information or statements concerning the suitability, capacity, fitness for purpose or performance of the Product are given solely on an “as is” and “as available” basis in this document, and Nokia reserves the right to change any such information and statements without notice. Nokia has made all reasonable efforts to ensure that the content of this document is adequate and free of material errors and omissions, and Nokia will correct errors that You identify in this document. But, Nokia total liability for any errors in the document is strictly limited to the correction of such error(s). Nokia does not warrant that the use of the software in the Product will be uninterrupted or error-free. NO WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY WARRANTY OF AVAILABILITY, ACCURACY, RELIABILITY, TITLE, NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, IS MADE IN RELATION TO THE CONTENT OF THIS DOCUMENT. IN NO EVENT WILL NOKIA BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, DIRECT, INDIRECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUT NOT LIMITED TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS OPPORTUNITY OR DATA THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR THE INFORMATION IN IT, EVEN IN THE CASE OF ERRORS IN OR OMISSIONS FROM THIS DOCUMENT OR ITS CONTENT. This document is Nokia proprietary and confidential information, which may not be distributed or disclosed to any third parties without the prior written consent of Nokia. Nokia is a registered trademark of Nokia Corporation. Other product names mentioned in this document may be trademarks of their respective owners, and they are mentioned for identification purposes only. Copyright © 2017 Nokia. All rights reserved. Important Notice on Product Safety This product may present safety risks due to laser, electricity, heat, and other sources of danger. Only trained and qualified personnel may install, operate, maintain or otherwise handle this product and only after having carefully read the safety information applicable to this product. The safety information is provided in the Safety Information section in the “Legal, Safety and Environmental Information” part of this document or documentation set. Nokia is continually striving to reduce the adverse environmental effects of its products and services. We would like to encourage you as our customers and users to join us in working towards a cleaner, safer environment. Please recycle product packaging and follow the recommendations for power use and proper disposal of our products and their components. If you should have questions regarding our Environmental Policy or any of the environmental services we offer, please contact us at Nokia for any additional information. DN09223983, Issue 04, Approval date: 2016-12-06 WARNING! Risk of eye damage caused by invisible laser beam. Make sure that the laser beam is switched off when optical cables are installed. CAUTION! Risk of personal injury. The cabinet is heavy. Additional personnel or lifting equipment might be needed when the cabinets are moved, unpacked, or lined up. In addition, follow any local regulations applicable to the installation. Notice: installations, including the outdoor cabinet, use only tested IP65 class outdoor cables with seals provided by Nokia. This is also recommended for indoor installations. Electrostatic discharge (ESD) damage the modules. Wear an ESD wrist strap or use a corresponding method when handling the modules. -2- Nokia AirScale System Module — AMOB Installing and Cabling Manual 1 Contents of delivery Contents Delivery Cabinet delivery Accessory bag Code Version 473240A/473240B A, 102/B, 101 Contents Code Quantity Lifting parts (2 pcs) 830028 2 Mounting brackets (2 pcs) 0876780A 2 Cable entry cover (1 pc) 830137 1 Guide plates (2 pcs) 829933 2 M5 screws (20 pcs) P206180 20 Connecting studs (4 pcs) 830470 4 Key (1 pc) 6490006 1 Cable ties (10 pcs) 6401142 10 Drilling jig (1 pc) P305124 1 EAC cable (1 pc) 995864 1 Positive power cable for FSM (1 pc) 995816 1 Negative power cable for FSM (1pc) 995817 1 Flexi Cabinet Outdoor (FCOB) Quick Guide P353858 1 Flexi Pole Kit, A (contains 2 pole kit assemlies) (FPKA) 471649A 1 Flexi Pole Kit, C (contains 2 pole kit assemlies) (FPKC) 472821A 1 OD External GNSS Enhanced Holdover (FYGG) 473185A 1 Flexi Enhanced External GPS Box (FYGE 472978A 1 Flexi Cabinet Outdoor (FCOB) FCOB accessory bag Optional items 2 Preparing the installation Accessory bag content 2x Lifting parts 1x Key -3- 2x Guide plates 2x Power cables 1x EAC cable 1x Cable entry cover 4x Connecting studs 20x M5 screws 10x Cable ties GO TO FIRST PAGE Nokia AirScale System Module — AMOB Installing and Cabling Manual 2x Mounting brakcets 1xFCOB Quick Guide 1x Drilling jig Installation tools and equipment Allen key TX20 and TX25 Side cutters Drill Slot scredriver: 2.5x0.4 mm Steel tape Cable stripping tool Wrench: 18 mm (0.7 in.) L-Shaped wrench 4x M12 expansion bolts Drill bit: 18 Screwdriver TX20 and TX25 Socket driver: 18 mm (0.7 in.) Scissors Socket spanner: 18 mm (0.7 in.) 2 Preparing the installation (continued) Dimensions and weight -4- GO TO FIRST PAGE Nokia AirScale System Module — AMOB Installing and Cabling Manual Clearances for vertical installation Clearances for horizontal installation NOTE: When installing and maintaining modules inside of the FCOB make sure that there is a minimum front clearance of 600 mm (23.6 in.) for door openings. NOTE: Make sure that there is a minimum bottom clearance of 160 mm (6.3 in.) for cable routing for vertical and horizontal installation. NOTE: Make sure that there is a minimum side clearance of 200 mm (7.9 in.) for better cabinet’s performance. Notice: The graphics in this Quick Guide show cabinet version A.102. The only difference between version A.102 and B.101 is in the door lock. Folowing instructions are valid for both cabinet versions. Checklist Delivery is complete. Equipment is not damaged. Site meets the minimum clearances. -5- GO TO FIRST PAGE Nokia AirScale System Module — AMOB Installing and Cabling Manual 3 Lifting FCOB Notice: The cabinet is heavy. Additional personnel or lifting equipement might be needed when the cabinet is moved, unpacked, or lined up. In addition, follow any local regulations applicable to the installation. 1. Attach the lifting parts to the attachment points. 2. Screw the lifting parts to the cabinet with ten M5 screws using a TX25 screwdriver. 3. Secure the crane to the cabinet. 4. Carefully lift the cabinet to the desired installation position. Notice: Make sure that the distance between crane lifting point and the cabinet’s lifting parts is minimum 300 mm (11.8 in.) to avoid bending the equipment. NOTE: The cabinet can be lifted when fully equipped (maximum lifting weight: 65 kg). Checklist The FCOB screws are tighten to 4.3 Nm (38.0 in-lb.). The cabinet is lifted according to the instructions. The cabinet is secured in position. -6- GO TO FIRST PAGE Nokia AirScale System Module — AMOB Installing and Cabling Manual 4 Installing FCOB onto a wall NOTE: FCOB can be installed from either side of the cabinet onto a wall. Only vertical installations on walls are possible for FCOB. NOTE: Make sure that the designated wall is flat and strong enough to bear the cabinet weight in any condition. NOTE: Install lifting parts before installing the cabinet onto a wall. See chapter Lifting the cabinet. 1. Mark the mounting hole locations on the wall and drill four 18 mm (0.7 in.) diameter holes for the M12 expansion bolts. NOTE: Use the drilling jig when marking the mounting hole locations. 2. Insert the M12 expansion bolts into holes in the wall. NOTE: When applying the bolts, ensure the fixing methods correspond to the wall’s properties. 3. Apply the upper mounting bracket to the wall. 4. Fix the upper mounting bracket to a wall with two M12 expansion bolts’s washers, spring washers and nuts. 5. Loosely fix the lower mounting bracket to the cabinet with three M5 screws a TX25 screwdriver. 6. Attach two connecting studs into the cabinet and fix them using a TX25 screwdriver -7- GO TO FIRST PAGE Nokia AirScale System Module — AMOB Installing and Cabling Manual 4 Installing FCOB onto a wall (continued) 7. Attach the cabinet onto the wall using the lifting parts and two connecting studs. 8. Tighten the upper mounting bracket to the lifting part with three M5 screw using a TX25 screwdriver. 9. Tighten the lower mounting bracket to the wall using two washers, spring washers and nuts dedicated to M12 expansion bolts. 10. Tighten the lower mounting bracket screws to the cabinet using a TX25 screwdriver. Checklist The FCOB screws are tighten to 4.3 Nm (38.0 in-lb.). The FCOB mounting brackets are secured to the wall. -8- GO TO FIRST PAGE Nokia AirScale System Module — AMOB Installing and Cabling Manual 5 Installing FCOB onto a pole with FPKA NOTE: Install lifting the parts before installing the cabinet on a pole. See chapter Lifting the cabinet. 1. Install the FPKA. NOTE: Make sure that the distance between the upper and lower FPKA kits is 482.5 mm (19.0 in.). NOTE: Remove all M8 screws from the FPKA kits before installing the FCOB. 2. Install the upper mounting bracket onto the FPKA with two M8 screws. 3. Loosley fix two M8 screws to the FPKA lower kit. NOTE: Leave 5 mm (0.2 in.) distance between the screw head and the FPKA kit. 4. Install the lower mounting bracket onto the bottom of the cabinet and loosely fix the three M5 screws using a TX25 screwdriver. 5. Insert two connecting studs into the cabinet’s wall and fix them using a TX25 screwdriver. -9- GO TO FIRST PAGE Nokia AirScale System Module — AMOB Installing and Cabling Manual 5 Installing FCOB onto a pole with FPKA (continued) 6. Hang the cabinet off the upper mounting bracket and attach it with the connecting studs. 7. Tighten the upper mounting bracket to the lifting part with five M5 screws using a TX25 screwdriver. 8. Tighten the FPKA lower mounting kit M8 srews to the FCOB lower mounting bracket. 9. Secure the lower mounting bracket to the cabinet with three M5 screws using TX25 screwdriver.. Checklist The FPKA kits are properly installed on a pole. The FPKA M8 screws are tighten to 20 Nm (14.7 ft-lb.) The FCOB mounting brackets are secured to the cabinet and to the FPKA kits. -10- GO TO FIRST PAGE Nokia AirScale System Module — AMOB Installing and Cabling Manual 6 Installing FCOB onto a pole with FPKC NOTE: Install lifting the parts before installing the cabinet on a pole. See chapter Lifting the cabinet. 1. Install the FPKC. NOTE: Make sure that the distance between the upper and lower FPKA kits is 482.5 mm (19.0 in.). NOTE: Remove all M8 screws from the FPKC kits before installing the FCOB. 2. Install the upper mounting bracket onto the FPKC with two M8 screws. 3. Loosley fix two M8 screws to the FPKC lower kit. NOTE: Leave 5 mm (0.20 in.) distance between the screw head and the FPKC kit. 4. Install the lower mounting bracket onto the bottom of the cabinet and loosely fix the three M5 screws using a TX25 screwdriver. 5. Insert two connecting studs into the cabinet’s wall and fix them using a TX25 screwdriver. -11- GO TO FIRST PAGE Nokia AirScale System Module — AMOB Installing and Cabling Manual 6 Installing FCOB onto a pole with FPKC (continued) 6. Hang the cabinet off the upper mounting bracket and attach it with the connecting studs. 7. Tighten the upper mounting bracket to the lifting part with five M5 screws using a TX25 screwdriver. 8. Tighten the FPKC lower mounting kit M8 srews to the FCOB lower mounting bracket. 9. Secure the lower mounting bracket to the cabinet with three M5 screws using TX25 screwdriver. Checklist The FPKC kits are properly installed on a pole. The FPKC M8 screws are tighten to 20 Nm (14.7 ft-lb.) The FCOB mounting brackets are secured to the cabinet and to the FPKC kits. -12- GO TO FIRST PAGE Nokia AirScale System Module — AMOB Installing and Cabling Manual 7 Installing FCOB vertically on a floor NOTE: It is recommended to install the lifting parts before installing the cabinet vertically on a floor if the cabinet Needs to be lifted to the desired position. See chapter Lifting the cabinet. 1. Mark the mounting hole locations on the floor and drill four 18 mm (0.7 in.) diameter holes for the M12 expansion bolts. NOTE: Use drilling jig when marking the mounting hole locations. 2. Insert the M12 expansion bolts into the holes in the floor. NOTE: When applying the bolts, ensure the fixing methods correspond to the floor’s properties. 3. Fix the mounting brackets onto the cabinet with six M5 screws using a TX25 screwdriver. 4. Place the cabinet with the mounting brackets onto the expansion bolts. 5. Fix the cabinet to the floor by securing the mounting brackets to the expansion bolts with four M12 washers, spring washers and nuts. Checklist The FCOB screws are tighten to 4.3 Nm (38.0 in-lb.). The FCOB mounting brackets are secured to the floor. -13- GO TO FIRST PAGE Nokia AirScale System Module — AMOB Installing and Cabling Manual 8 Installing FCOB horizontally on a floor 1. Mark the mounting hole locations on the floor and drill four 18 mm (0.7 in.) diameter holes for the M12 expansion bolts. NOTE: Use drilling jig when marking the mounting hole locations. 2. Insert the M12 expansion bolts into the holes in the floor. NOTE: When applying the bolts, ensure the fixing methods correspond to the floor’s properties. 3. Attach the mounting bracket onto the cabinet. 4. Fix the mounting brackets onto the cabinet withten M5 screws using a TX25 screwdriver. NOTE: It is recommended to use a long screwdriver, no shorter than 160 mm (6.3 in.). -14- GO TO FIRST PAGE Nokia AirScale System Module — AMOB Installing and Cabling Manual 8 Installing FCOB horizontally on a floor (continued) 5. Place the cabinet with mounting brackets onto the expansion bolts. 6. Fix the cabinet to the floor by securing the mounting brackets to the expansion bolts with four M12 washers, spring washers and nuts. NOTE: When applying the bolts, ensure the fixing methods correspond to the floor’s properties. Installing cable entry cover NOTE: Follow these instructions after performing FSIH or AirScale SM Indoor cabling. For more information on cabling, see the Installing Flexi Cabinet Outdoor (FCOB) DN09223971 document. 7. Connect the cables. Notice: Make sure that the distance between crane lifting point and the cabinet’s lifting parts is minimum 300 mm (11.8 in.) to avoid bending the equipment. 8. Attach the cable entry cover by inserting the side wedges into the cabinet. -15- GO TO FIRST PAGE Nokia AirScale System Module — AMOB Installing and Cabling Manual 8 Installing FCOB horizontally on a floor (continued) 9. Secure the cable entry cover with two M5 screws using a TX25 screwdriver . 10. Secure the cables with cable ties. NOTE: Tie power cables and grounding cable separately from other cables. NOTE: AMFG FCOA installation kit (474417A) is required to install AMOB in FCOA.It is recommended to fix cable ties to the mounting bracket. Checklist The FCOB screws are tighten to 4.3 Nm (38.0 in-lb.). The FCOB mounting brackets are secured to the floor. Optical cables do not exceed the maximum bending radius of 50 mm (2.0 in.). The cable entry cover is secured to the cabinet. 9 Stacking FCOBs NOTE: Only horizontal installations are possible for stacked FCOBs. A maximum of two FCOBs can be stacked. Before stacking FCOBs, install the lower cabinet horizontally on a floor. See chapter Installing horizontally on a floor. NOTE: Modules installed inside of the FCOB and then stacked on top of another FCOB must comply with the ETSI EN 300 019-2-4 Class 4M5 standard. NOTE: Consult Nokia about third-party installation on top of FCOB. NOTE: Nokia AirScale System Module Indoor installed inside of FCOB must not be stacked on top of another FCOB. 1. Insert four connecting studs on the top of the lower cabinet and fix them with a TX25 screwdriver. -16- GO TO FIRST PAGE Nokia AirScale System Module — AMOB Installing and Cabling Manual 9 Stacking FCOBs (continued) 2. Install the mounting brackets to the upper cabinet with six M5 screws using a TX25 screwdriver. 3. Place and secure the upper cabinet onto the connecting studs of the lower cabinet. 4. Tighten the upper cabinet mounting brackets to the lower cabinet with two M5 screws. -17- GO TO FIRST PAGE Nokia AirScale System Module — AMOB Installing and Cabling Manual 9 Stacking FCOBs (continued) Installing cable entry cover NOTE: Follow these instructions after completing the FSIH. For more information on cabling, see the Installing Flexi Cabinet Outdoor (FCOB) DN09223971 document. 5. Connect the cables. Notice: Do not exceed the maximum ben ding radius of 50 mm (2.0 in.) for the optical cables. 6. Attach the cable entry cover to both cabinets by inserting the side wedges into the cabinet. 7. Secure the cable entry covers with four M5 screws using a TX25 screwdriver. 8. Secure the cables with cable ties. NOTE: It is recommended to fix cable ties to the lower cabinet mounting bracket. Checklist The FCOB screws are tighten to 4.3 Nm (38.0 in-lb.). The lower FCOB mounting brackets are secured to the floor. The upper FCOB is secured to the lower FCOB. Optical cables do not exceed the maximum bending radius of 50 mm (2.0 in.). The cable entry cover is secured to the cabinet. -18- GO TO FIRST PAGE Nokia AirScale System Module — AMOB Installing and Cabling Manual 10 Installing 3U casing on top of FCOB NOTE: he 3U casing can be installed on top of the FCOB, but only when the FCOB is installed in the horizontal position. See chapter Installing horizontally on a floor. NOTE: A maximum of three 3U casings can be installed in Earthquake Zone 4 areas and a maximum of five 3U casings can be installed in Earthquake Zone 2 areas. NOTE: Modules installed on top of the FCOB must comply with the ETSI EN 300 019-2-4 Class 4M5 standard. NOTE: Consult Nokia about third-party installation on top of FCOB. NOTE: Nokia AirScale System Module Indoor must not be installed on top of the FCOB. 1. Insert four connecting studs on top of the cabinet and fix them using a TX25 screwdriver. 2. Place and secure the 3U casing bracket onto the connecting studs of the cabinet. 3. Fix the 3U casing bracket onto the cabinet with two M5 screws. -19- GO TO FIRST PAGE Nokia AirScale System Module — AMOB Installing and Cabling Manual 10 Installing 3U casing on top of FCOB 4. Install the 3U casing on top of another 3U casing using the connecting studs. NOTE: If necessary, repeat this step to install another 3U casings. Checklist The cabinet is properly installed on a floor. The 3U casing is properly installed to the cabinet. 11 Installing FCOB on top of 3U casing NOTE: The FCOB can be installed on top of the 3U casing, but only when the FCOB is installed in the horizontal position. See chapter Installing horizontally on a floor. NOTE: A maximum of three 3U casings can be installed under FCOB in Earthquake Zone 2 areas. Notice: Do not install FCOB on the 3U casing in Earquake Zone 4 areas. 1. Install the mounting brackets to the cabinet with six M5 screws using a TX25 screwdriver. -20- GO TO FIRST PAGE Nokia AirScale System Module — AMOB Installing and Cabling Manual 11 Installing FCOB on top of 3U casing 2. Place and secure the cabinet onto the connecting studs of the 3U casing. 3. Tighten the cabinet mounting brackets to the 3U casing with two M5 screws. Checklist The 3U casing is secured to the floor. The FCOB is secured to the 3U casing. -21- GO TO FIRST PAGE Nokia AirScale System Module — AMOB Installing and Cabling Manual 12 Installing FYGG inside of FCOB 1. Remove the four M5 screws and pull out the dummy casing. 2. Loosen the small plate middle M4 screw and remove the side M4 screw. 3. Rotate the small plate by 180 degrees. 4. Fix the small plate side M4 screw and tighten the middle M4 screw. 5. Install the FYGG into the dummy casing with three M5X35 screws. 6. Reinsert and reinstall the dummy casing with FYGG into the FCOB using four M5 screws. 7. Connect the power cables between the PDU and the FYGG. Checklist The small plate position is changed. The FYGG is secured to the dummy casing. The dummy casing screws are tighten to 4.3 Nm (38 in-lb.). -22- GO TO FIRST PAGE Nokia AirScale System Module — AMOB Installing and Cabling Manual 13 Installing FYGE inside of FCOB 1. Remove the four M5 screws and pull out the dummy casing. 2. Loosen the small plate middle M4 screw and remove the side M4 screw. 3. Rotate the small plate by 180 degrees. 4. Fix the small plate side M4 screw and tighten the middle M4 screw. 5. Install the FYGE into the dummy casing with three M5X35 screws. 6. Reinsert and reinstall the dummy casing with FYGE into the FCOB using four M5 screws. 7. Connect the power cables between the PDU and the FYGE. Checklist The small plate position is changed. The FYGE is secured to the dummy casing. The dummy casing screws are tighten to 4.3 Nm (38 in-lb.). -23- GO TO FIRST PAGE Nokia AirScale System Module — AMOB Installing and Cabling Manual 14 Installing FSIH inside of FCOB 1. Insert the lower guide plate into the cabinet’s slots. 2. Insert the upper guide plate into the cabient’s slots. 3. Insert the FSIH into the cabinet using the guide plates. NOTE: Note the FSIH terminal block position. 4. Fix the FSIH into the cabinet using four M5 screws using a TX25 screwdriver. NOTE: For cabling FSIH inside of FCOB, see the Installing Flexi Cabinet Outdoor (FCOB) DN09223971 document. Checklist The FSIH is inserted inside of the cabinet using the left slots. The FSIH is secured to the cabinet. The screws are tighten to 4.3 Nm (38 in-lb.). -24- GO TO FIRST PAGE Nokia AirScale System Module — AMOB Installing and Cabling Manual 15 Installing AirScale SM Indoor inside of FCOB NOTE: The slots on the right are dedicated for AirScale SM Indoor installation. 1. Insert the upper guide plate into the cabinet’s slots. 2. Insert the lower guide plate into the cabient’s slots. 3. Insert the AMIA subrack into the cabinet using guide plates. 4. Fix the AMIA subrack into the cabinet using four M5 screws using a TX25 screwdriver. -25- GO TO FIRST PAGE Nokia AirScale System Module — AMOB Installing and Cabling Manual 15 Installing AirScale SM Indoor inside of FCOB (continued) 5. Loosen the dummy panel screws using TX10 screwdriver. 6. Remove the dummy panels one by one from the AMIA subrack. NOTE: The subrack is delivered with factory-installed dummy panels. Only remove dummy panels from the slots where you are going to install a plug-in unit. 7. Pick up the ASIA plug-in units in sequence. Insert each plug-in unit to AMIA subrack handling them carefully. 8. Fix ASIA screws to the AMIA subrack using a TX10 screwdriver. -26- GO TO FIRST PAGE Nokia AirScale System Module — AMOB Installing and Cabling Manual 15 Installing AirScale SM Indoor inside of FCOB (continued) 9. Pick up the ABIA plug-in units in sequence. Insert each plug-in unit to AMIA subrack handling them carefully. 10. Fix ABIA screws to AMIA subrack using a TX10 screwdriver. NOTE: For cabling AirScale SM Indoor inside of FCOB, see the Installing Flexi Cabinet Outdoor (FCOB) DN09223971 document. Checklist The AirScale SM Indoor is inserted inside of the cabinet using the right slots. The AMIA subrack is secured to the cabinet. The AMIA subrack screws are tighten to 4.3 Nm (38 in-lb.). The ASIA and ABIA plug-in units are secured to the AMIA subrack. The ASIA and ABIA plug-in units screws are tighten to 1 Nm (8.9 in-lb.). All slots have either a plug-in unit or a dummy panel installed. There are no empty slots. -27- GO TO FIRST PAGE
0
You can add this document to your study collection(s)
Sign in Available only to authorized usersYou can add this document to your saved list
Sign in Available only to authorized users(For complaints, use another form )