Design of Concrete Structure - Complex Engineering Problem
Design a complete frame structure (slabs, beams, column, footings and retaining walls) for the
data as given below. You are required to prepare the architectural plans at first with elevation.
Then draw structural drawings for all members, using AUTCAD. You are also required to
submit the design report with hard copy of structural drawings, printed on A3 sheet. For all
cases, take the loads from ACI 308 – 14 and assume fc’ = 3000 psi with fy = 60000 psi. Assume
compatible roof clearance.
Group
Problem Statement
1
A residential 3 storey apartment, having two sets of
Number
flats on each floor. All flats are standard with 3 x
Serial Number of Students
(As per Roll Call)
Sr. 1 to 7
bedrooms (with attach bath), drawing room, tv
lounge, kitchen and a store, with balcony of front
side. The residential building has a parking, designed
2
at basement. The plot size is 120’ x 180’
A bachelors hostel, with 2 x persons in each room
having attach bath facility. The hostel is a 4 storey
Sr. 8 to 14
with a capacity of 500 students. There must be a
dining, recreational and prayer room of suitable
dimensions. The hostel is proposed to be constructed
on an area of 150’ x 200’. At basement, hostel has a
3
big storage facility as well.
A cinema hall, with capacity of 500 audiences. The
cinema hall must have an entrance lobby, storage
Sr. 15 to 21
area, canteen / cafeteria and offices. It should be s
stories and select the height as per design
4
requirement. Assume car parking at basement
A commercial plaza of size 45’ x 90’. The plaza is 4
stories and must compensate at least 10 shops at each
Sr. 22 to 28
floor level. Consider a water tank at basement with
size of 20ft x 20ft x 10ft. There must be lavatory and
5
prayer area in the plaza at centralized area
A car showroom, having size of 150ft x 250ft size.
The showroom is a 3 storey building with offices,
Sr. 29 to 35
washroom, prayer area, cafeteria, a conference and
visual room. Adjust the roof height accordingly.
6
Assume repair workshop at basement of suitable size.
A sports complex, having swimming pool facility.
The swimming pool is of size 72ft x 45ft, with mean
Sr. 36 to 42
depth of 6 ft. There is a single storey administration
building beside swimming pool, having 3 offices of
size 15ft x 15ft and a washroom / changeover room
7
8
of size 15ft x 30ft.
A three storey warehouse, having size of plot 200ft x
200ft. The warehouse must have roof clearance of at
least 20 feet for each level. There is no basement.
A school building, double storey, with total 10 class
rooms in each floor. There should be washroom
facility at each level, one centralized cafeteria, central
lawn and seminar hall. The school is proposed to be
constructed on area of 250ft x 500ft. The basement
contains 1 x store room of size 25ft x 50ft
Sr. 43 to 49
Sr. 50 to 56
Download