CONTRACT DATA SHEET 1.0 PURCHASER ONGC Tripura Power Company Private Ltd/ 760±50MW CCPP 2.0 LOCATION Pallatana Village, Udaipur-Kakraban State Highway, South of Tripura 3.0 HRSG TYPE 4.0 GT FUEL Horizontal, Natural Circulation, Water tube, Triple Pressure with Reheat Natural Gas 5.0 HRSG FUEL Unfired 6.0 HEAT SOURCE GT Exhaust gas 7.0 HEAT TRANSFER SURFACE DETAILS: SECTION Superheater-HP-2 Superheater-HP-1B Superheater-HP-1A Superheater-IP Superheater-LP Reheater--II Reheater--I Evaporator-HP Evaporator-IP Evaporator-LP Economiser-HP Economiser-IP WPH 8.0 TYPE Solid finned tubes Solid finned tubes Solid finned tubes Serrated finned tubes Serrated finned tubes Solid finned tubes Solid finned tubes Serrated finned tubes Serrated finned tubes Serrated finned tubes Serrated finned tubes Serrated finned tubes Serrated finned tubes TUBE SIZE 31.8 X4.8 31.8 X4.5 38.1 X3.6 38.1 X3.25 51 X 3.25 51 X3.25 51 X3.25 38.1X 3.6 38.1X 3.25 38.1X 3.25 38.1 X 3.6 38.1 X 3.25 38.1 X 3.25 AREA (SQ.M) 11510.57 1561.35 1377.25 12165.67 47101.67 30477.54 41560.28 88661.97 4332.03 38789.6 SAFETY VALVES LOCATION MAKE Steam drum valve I-HP Steam drum valve II-HP Superheater valve I-HP Reheater inlet valve I Reheater inlet valve II Reheater outlet valve II Steam drum valve I-IP Steam drum valve II-IP Superheater valve I-IP Steam drum valve I-LP Steam drum valve II-LP Superheater valve I-LP CBD tank BHEL BHEL BHEL BHEL BHEL BHEL BHEL BHEL BHEL BHEL BHEL BHEL BHEL SET PRESSURE kg/cm2(g) OPEN CLOSE 164 155.8 168.9 160.5 150.5 143 44 41.8 45.4 43.2 39.9 38 52 49.4 53.5 50.9 47.5 45.2 10.4 9.9 10.7 10.2 9 8.6 7 --- TYPE 1739 WB 1739 WB 1739 WD 1776 WB 1786 WB 1766 WD 1717 WB 1717 WB 1717 WB 1811MA-3X-20 1811PA-3X-20 1811MA-3X-20 1905M/P1&P2 Page 1 of 2 CONTRACT DATA SHEET 9.0 SAFETY RELIEF VALVES LOCATION MAKE IP Economiser Water Preheater BHEL BHEL 10.0 SET PRESSURE kg/cm2(g) 100 50 TYPE 1916H 1912P WATER LEVEL GAUGES: LOCATION MAKE VISIBILITY (MM) 400 400 400 No MODEL Steam drum -HP- Local Steam drum -IP- Local Steam drum -LP- Local BHEL BHEL BHEL TWO TWO TWO MOBREY 975 ONE Steam drum -IP- EWLI MOBREY 695 ONE Steam drum -LP- EWLI MOBREY 695 ONE TYPE 0473 (RH) TYPE 0473 (RH) TYPE 0473 (RH) Hydrastep 2468 CABD Hydrastep 2468 CABD Hydrastep 2468 CABD Steam drum -HP- EWLI IBD. tank - Local LEVCON 762 ONE 11.0 HRSG MAIN STACK Inner Diameter Height 12.0 ----- m m 6.5 60 HRSG OPERATING CONDITIONS: The HRSG is designed to generate steam at 134 kg/cm2(g) & 540 ±5 °C at MSSV outlet at GT base load at design ambient temperature of 27°C with Natural Gas firing in GT. At all other conditions, the superheater steam temperature is dependent on GT exhaust temperature and flow for various ambient and GT load conditions. Page 2 of 2