NUMBER OF SHEET WHERE DETAIL APPEARS DETAIL CALLOUT DETAIL TITLE # SHEET # SCALE T T EXISTING THERMOSTAT V OR VOLUME DAMPER C COMBINED DAMPER GENERAL: 2" PIPE SIZE TAG (DIAMETER) ABOVE GROUND PIPING NUMBER OF SECTION ON SHEET NUMBER OF SHEET WHERE SECTION APPEARS X PIPE SLOPE TAG 1/8" / 12" SLOPE SHEET NOTE INV. ELEV:-5' - 1" (E) CONTINUATION SYMBOL Room ROOM NAME AND NUMBER HEATING WATER: ITEM TO BE REMOVED EXISTING PIPE TAG PIPING BEING REMOVED LIGHT LINE INDICATES BACKGROUND AND EXISTING WORK HEAVY LINE INDICATES NEW WORK HWR HWS HCR HCS HHWR HEATING WATER RETURN HEATING WATER SUPPLY HEATING/CHILLED WATER RETURN HEATING/CHILLED WATER SUPPLY HIGH TEMPERATURE HEATING WATER RETURN DASH LINE INDICATES FUTURE AND OTHER DISCIPLINE WORK HHWS HIGH TEMPERATURE HEATING WATER SUPPLY RFR RFS RADIANT FLOOR HEAT RETURN RADIANT FLOOR HEAT SUPPLY AREA NOT IN CONTRACT HVAC SYMBOLS DUCTWORK: 24"x10" RECTANGULAR/SQUARE DUCT SIZE TAG (WIDTH x HEIGHT) 24"/10" OVAL DUCT SIZE TAG (WIDTH / HEIGHT) 24"Ø ROUND DUCT SIZE TAG (DIAMETER) (E) EXISTING DUCT TAG DUCT BEING REMOVED SUPPLY AIR S/A PIPE INVERT ELEVATION TAG REFRIGERATION: REFRIGERANT DISCHARGE RD REFRIGERANT HOT GAS BYPASS HGB REFRIGERANT LIQUID RL REFRIGERANT SUCTION RS COMPONENTS: CONCENTRIC REDUCER PIPE DROP ECENTRIC REDUCER PIPE RISE PIPE TEE PLUG OUTSIDE AIR O/A S 45 DEGREE TEE SOLENOID VALVE RETURN AIR R/A CAP TRANSFER AIR T/A EXHAUST AIR E/A BALL VALVE HOSE END BALL VALVE WITH CAP & CHAIN RELIEF AIR L/A RECTANGULAR SUPPLY/OUTSIDE AIR DUCT RISE ROUND SUPPLY/OUTSIDE AIR DUCT RISE DROP DROP DROP CHECK VALVE THREE WAY VALVE GLOBE VALVE OVAL SUPPLY/OUTSIDE AIR DUCT RISE RECTANGULAR RETURN/TRANSFER AIR DUCT RISE DROP DROP ROUND RETURN/TRANSFER AIR DUCT RISE DROP OVAL RETURN/TRANSFER AIR DUCT RISE DROP RECTANGULAR EXHAUST/RELIEF AIR DUCT RISE DROP ROUND EXHAUST/RELIEF AIR DUCT RISE DROP OVAL EXHAUST/RELIEF AIR DUCT RISE 24"x24" 24"Ø PUMP 6" ORD-1 HORIZONTAL OFFSET SUPPLY/RETURN/EXHAUST 90° ELBOW SQUARE CORNER ELBOW 90° RECTANGULAR TAKE-OFF WITH 45° TAPER 90° CONICAL SPIN-IN PLUMBING FIXTURE PLUMBING FIXTURE TAG ABBREVIATIONS AB ABV ACH ACOUS AD ADD ADDL AF AFF AG ALT ALUM AP APPROX ARCH ATC 45° TAKE-OFF 90° DIVERGING RECTANGULAR TEE DUCT OR PLENUM LINING (SEE PROJECT GENERAL NOTE 26) FLEXIBLE DUCT DIFFUSERS, GRILLES, AND REGISTERS: SUPPLY OUTLET X X X EXHAUST GRILLE (EG) RETURN/EXHAUST INLET INLET/OUTLET SIZE GRILLES, REGISTERS, AND DIFFUSERS TAG CFM TYPE (SEE SCHEDULE) HVAC SYMBOLS CONT. EQUIPMENT: MECHANICAL EQUIPMENT XX-XX XX-XX (E)XX-XX (E) XX-XX XX-XX MECHANICAL EQUIPMENT TAG MECHANICAL EQUIPMENT MECHANICAL EQUIPMENT REQUIRING ELECTRICAL CONNECTION TAG 6" RD-1 ROOF DRAIN DRAIN SIZE DRAIN TAG TYPE (SEE SCHEDULE/SPECIFICATION) IPP IW JST SPC JT KW KWH LAB LAT LB LB/HR LF LOC LP LVR LWT M/A MAC MAN MATL MAV MAX MBH MD MECH MFR MIN MISC MTR N/A NC NC NIC NO NO NOM NPLV NTS OBD HB RECTANGULAR TO ROUND TRANSITION SUPPLY GRILLE (SG) GATE VALVE BALANCING/ MEASURING VALVE HZ IN INL INSUL INT INV INWG IPLV AUTO AVE BFF BHD BHP BI BLDG BLW BO BOD BOP BOS BOT BSMT BTU BTUH BTWN CAP CB CCW CF CF CFCV CFH CFM CH CI CLG CLG CNTFGL CO COL COMB CONC COND EXISTING MECHANICAL EQUIPMENT EXISTING MECHANICAL EQUIPMENT TAG (TYPICAL FOR ALL EXISTING TAGS) MECHANICAL EQUIPMENT EXISTING MECHANICAL EQUIPMENT REQUIRING ELECTRICAL CONNECTION TAG CONF CONN CONST CONT EQUIPMENT FOR REFERENCE EQUIPMENT TAG (REFER TO OTHER DISCIPLINE FOR ADDITIONAL INFORMATION) COORD CONTR ABOVE BASE ABOVE AIR CHANGES PER HOUR ACOUSTICAL AREA DRAIN ADDENDUM ADDITIONAL AIR FOIL ABOVE FINISHED FLOOR ABOVE GROUND ALTERNATE ALUMINUM ACCESS PANEL APPROXIMATE ARCHITECT/ ARCHITECTURAL AUTOMATIC TEMPERATURE CONTROL AUTOMATIC AVERAGE BELOW FINISHED FLOOR BOTTOM HORIZONTAL DISCHARGE BRAKE HORSEPOWER BACKWARDS INCLINED BUILDING BELOW BY OTHER BOTTOM OF DUCT BOTTOM OF PIPE BOTTOM OF STEEL BOTTOM BASEMENT BRITISH THERMAL UNITS BRITISH THERMAL UNITS PER HOUR BETWEEN CAPACITY CATCH BASIN COUNTER CLOCKWISE CABINET FAN CHEM FEEDER CONSTANT FLOW CONTROL VALVE CUBIC FEET PER HOUR CUBIC FEET PER MINUTE CABINET HEATER CAST IRON CEILING COOLING CENTRIFUGAL CLEAN OUT COLUMN COMBINATION CONCRETE CONDENSATE/ CONDENSER CONFERENCE CONNECT CONSTRUCTION CONTINUE/ CONTINUATION CONTRACT/ CONTRACTOR COORDINATE COEFFICIENT OF COP CTE CTR CUFT CV CW dB D DB DBD DDC DEG DET DIA DIAG DISCH DIV DMPR DN DP DWDI DWG DX EA EAT EER EFF EL ELEC ELEV EQ EQUIP ESP EWT EXH EXIST EXP EXT F FC FD FDC FDV FLA FLEX FLG FLR FOB FOT FPF FPI FPM FRP COEFFICIENT OF PERFORMANCE CONNECT TO EXISTING CENTER CUBIC FEET CONSTANT VOLUME CLOCKWISE DECIBELS DRAIN DRY BULB DOWN BLAST DISCHARGE DIRECT DIGITAL CONTROL DEGREE DETAIL DIAMETER DIAGONAL DISCHARGE DIVISION DAMPER DOWN DIFFERENTIAL PRESSURE DOUBLE WIDTH DOUBLE INLET DRAWING DIRECT EXPANSION EACH ENTERING AIR TEMPERATURE ENERGY EFFICIENCY RATIO EFFICIENCY ELBOW ELECTRICAL ELEVATION EQUAL EQUIPMENT EXTERNAL STATIC PRESSURE ENTERING WATER TEMPERATURE EXHAUST EXISTING EXPANSION EXTERIOR DEGREES FAHRENHEIT FORWARD CURVED FIRE DAMPER FIRE DEPARTMENT CONNECTION FIRE DEPARTMENT VALVE FULL LOAD AMPS FLEXIBLE FLANGE FLOOR FLAT ON BOTTOM REDUCER FLAT ON TOP REDUCER FINS PER FOOT FINS PER INCH FEET PER MINUTE FIBERGLASS REINFORCED PIPE OC OD ODP OF OFCI OPNG OV PBD PD PLBG POC PPH PREL PRESS PRIM PRV PSI PSIG PVC PW PWR R RD REC RED REFR REQD RFZ RH RM RPM SCFM SCHED SD SECT SEER SF SHT SIM SLV SM SO SP SP SPEC SPS SQ SS S/S STD STRUCT SUCT SUSP SWSI TCP TD TDR TEFC TEMP THD TOD TOS TOP TP TRANS TYP V VAV VEL VENT VERT WB WSEC PRESSURE DROP PLUMBING POINT OF CONNECTION POUNDS PER HOUR PRELIMINARY PRESSURE PRIMARY PRESSURE REDUCING VALVE POUNDS PER SQUARE INCH POUNDS PER SQUARE INCH GAUGE POLYVINYL CHLORIDE POTABLE WATER POWER DUCT RISER ROOF DRAIN RECESSED REDUCER REFRIGERATION REQUIRED RADIANT FLOOR ZONE RELATIVE HUMIDITY ROOM REVOLUTIONS PER MINUTE STANDARD CUBIC FEET PER MINUTE SCHEDULE SMOKE DAMPER SECTION SEASONAL ENERGY EFFICIENCY RATIO SQUARE FOOT SHEET SIMILAR SLEEVE SURFACE MOUNT SCREENED OPENING STANDPIPE STATIC PRESSURE SPECIFICATION STATIC PRESSURE STATION SQUARE STAINLESS STEEL START/STOP STANDARD STRUCTURAL SUCTION SUSPENDED SINGLE WIDTH SINGLE INLET TEMPERATURE CONTROL PANEL TEMPERATURE DROP TRENCH DRAIN TOTALLY ENCLOSED FAN COOLED TEMPERATURE TOP HORIZONTAL DISCHARGE TOP OF DUCT TOP OF STEEL TOP OF PIPE TOTAL PRESSURE TRANSITION TYPICAL VOLT VARIABLE AIR VOLUME VELOCITY VENTILATION VERTICAL WET BULB WASHINGTON STATE ENERGY CODE No. 1. 2. AC ACU ACC ACCU AIR COMPRESSOR AIR CONDITIONING UNIT AIR COOLED CONDENSER AIR COOLED CONDENSING UNIT ERU FCU VRF ENERGY RECOVERY UNIT FAN COIL UNIT VARIABLE REFRIGERANT FLOW UNIT THE FOLLOWING NOTES APPLY TO ALL MECHANICAL, PLUMBING, AND FIRE PROTECTION DRAWINGS. ADDITIONAL NOTES MAY BE INDICATED ON INDIVIDUAL DRAWINGS. M0.1 MECHANICAL LEGEND, ABBREVIATIONS, AND GENERAL NOTES M3.1 GROUND FLOOR HVAC PLAN DRAWINGS INDICATE CONNECTIONS FOR EQUIPMENT TO BE FURNISHED BY THE OWNER OR AS THE WORK OF OTHER TRADES. VERIFY LOCATION OF EQUIPMENT, ROUGH-IN LOCATIONS, AND TYPE OF CONNECTIONS PRIOR TO PREPARATION OF SHOP DRAWINGS OR SUBMITTALS, AND PRIOR TO INSTALLATION OF SERVICE CONNECTIONS. DO NOT INTERFERE WITH ACCESS FOR MAINTENANCE AND REMOVAL OR REPLACEMENT OF EQUIPMENT. M3.2 FIRST FLOOR HVAC PLAN M6.1 MECHANICAL SCHEDULES M7.1 MECHANICAL CONTROL 3. COORDINATE THE PHASING AND INSTALLATION OF NEW WORK WITH THE WORK OF ALL OTHER TRADES. BEAR THE TOTAL EXPENSE FOR ANY ADDITIONAL WORK WHICH MAY BE CAUSED BY IMPROPER SEQUENCING OF CONSTRUCTION ACTIVITIES. 4. LOCATE MECHANICAL DEVICES (E.G. TEMPERATURE AND HUMIDITY SENSORS, PANELS, AND SWITCHES), SO THAT THEY DO NOT CONFLICT WITH EXISTING CONSTRUCTION (E.G. WAINSCOT, DOOR HARDWARE), ELECTRICAL DEVICES (E.G. LIGHT SWITCHES, SPEAKERS, OUTLETS), AND THE WORK OF OTHER TRADES. 5. PROVIDE CONCRETE HOUSEKEEPING PAD FOR CONDENSING UNIT AS INDICATED BY MANUFACTURER RECOMMENDATIONS. 6. COORDINATE EQUIPMENT POWER CONNECTION REQUIREMENTS AND ELECTRICAL CHARACTERISTICS WITH ELECTRICAL DRAWINGS AND CONNECTION REQUIREMENTS. COORDINATE VARIATION IN ELECTRICAL CHARACTERISTICS FROM SCHEDULED VALUES. CHANGES TO ELECTRICAL CHARACTERISTICS (E.G. VOLTAGE, AMPS, HORSEPOWER, ETC.) SHALL BE SUBJECT TO APPROVAL. BEAR THE TOTAL EXPENSE FOR REQUIRED REVISION TO THE ELECTRICAL SCOPE OF WORK CAUSED BY VARIATION FROM THE SCHEDULED REQUIREMENTS. 7. EQUIPMENT SHORT CIRCUIT CURRENT RATINGS (SCCR) SHALL BE NOT LESS THAN THE INTERRUPTING RATING OF THE BRANCH CIRCUIT OVER CURRENT PROTECTIVE DEVICE SUPPLYING POWER TO THE EQUIPMENT. REFER TO ELECTRICAL SCHEDULES FOR BRANCH CIRCUIT OVER CURRENT DEVICE INTERRUPTING RATINGS. 8. COORDINATE THE LOCATION OF WORK TO PROVIDE CLEARANCES WITH EXISTING LIGHTING FIXTURES AND OTHER CEILING MOUNTED DEVICES AS REQUIRED TO ALLOW FOR REMOVAL AND MAINTENANCE ACCESS. 9. PROVIDE SUPPORTS AND SEISMIC RESTRAINTS FOR PIPES, DUCTS, AND EQUIPMENT AS SPECIFIED, AS REQUIRED, AND AS SHOWN ON THE DRAWINGS. IF REQUIRED FOR INSTALLATION OF PIPES, DUCTS, AND EQUIPMENT, DESIGN AND PROVIDE ADDITIONAL STRUCTURAL MEMBERS BETWEEN COLUMNS, JOISTS, AND STRUCTURAL FRAME TO MEET SUPPORT AND SEISMIC RESTRAINT REACTIONS (FORCES, MOMENTS, DEFLECTIONS). STRUCTURAL MEMBERS AND ANCHORAGES SHALL BE DESIGNED BY A PROFESSIONAL ENGINEER LICENSED IN THE STATE IN WHICH THE PROJECT IS LOCATED. REFER TO STRUCTURAL DRAWINGS FOR DESIGN CRITERIA. SUBMIT STRUCTURAL MEMBER SHOP DRAWINGS AND CALCULATIONS FOR REVIEW. STRUCTURAL MEMBERS, BOLTS, AND WELDS SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS SHOWN ON THE STRUCTURAL DRAWINGS AND INDICATED IN THE SPECIFICATIONS. NO WELDING, BOLTING, OR OTHER MEANS OF ATTACHMENT TO THE STRUCTURAL MEMBERS SHALL BE MADE ON PORTIONS OF STRUCTURAL MEMBERS AT OR NEAR CONNECTIONS BETWEEN STRUCTURAL MEMBERS ON ANY ELEMENTS DESIGNATED IN THE SEISMIC LOAD RESISTING SYSTEMS UNLESS APPROVED BY THE STRUCTURAL ENGINEER. SUPPORTS SHALL NOT INDUCE TORSIONAL LOADS INTO SUPPORTING STRUCTURAL FRAMING. 10. DO NOT CORE DRILL OR DRILL THROUGH BEAMS, COLUMNS OR SHEAR WALLS. 11. PROVIDE PIPE SLEEVES AND PENETRATION SEALS AS REQUIRED FOR THE INSTALLATION OF PIPING SYSTEMS. REFER TO SPECIFICATIONS FOR REQUIREMENTS. 12. COORDINATE THE LAYOUT OF EQUIPMENT, DUCTWORK, PIPING, AND APPURTENANCES SO THAT IT FITS INTO THE SPACE ALLOTTED. PROVIDE SERVICE ACCESS AND CLEARANCES AS INDICATED ON DRAWINGS, AS REQUIRED BY CODES, AND AS RECOMMENDED BY THE MANUFACTURER FOR THE INSTALLATION, REMOVAL, ENTRY, SERVICING, AND MAINTENANCE OF EQUIPMENT. PRIOR TO INSTALLATION, COORDINATE LAYOUT OF EQUIPMENT, DUCTWORK, PIPING, AND APPURTENANCES WITH ALL OTHER TRADES TO AVOID BLOCKING SERVICE OR REPLACEMENT ACCESS FOR NEW AND EXISTING EQUIPMENT AND EQUIPMENT INSTALLED BY OTHERS. 13. DRAWINGS ARE DIAGRAMMATIC AND SHOW APPROXIMATE LOCATIONS OF EQUIPMENT, DUCTWORK, PIPING, AND APPURTENANCES. DRAWINGS DO NOT SHOW REQUIRED TRANSITIONS, OFFSETS, FITTINGS, AND DEVICES. REFER TO DETAILS, DIAGRAMS, AND SPECIFICATIONS FOR REQUIRED SYSTEM APPURTENANCES, CONTROL DEVICES, ETC. INSTALL DEVICES IN ACCORDANCE WITH DEVICE MANUFACTURER RECOMMENDATIONS. CAREFULLY INVESTIGATE ELEMENTS OF CONSTRUCTION THAT COULD AFFECT THE WORK TO BE PERFORMED AND ARRANGE NEW WORK ACCORDINGLY. PREPARE COORDINATION DRAWINGS FOR NEW WORK, WHICH ARE COORDINATED WITH THE APPROVED AND INSTALLED WORK OF OTHER TRADES. PROVIDE REQUIRED OFFSETS, FITTINGS, TRANSITIONS, SUPPORTS AND OTHER APPURTENANCES AS REQUIRED. BEAR THE TOTAL EXPENSE OF RE-WORK THAT IS CAUSED BY FAILURE TO COORDINATE. 14. PROVIDE MAXIMUM HEADROOM AND CLEARANCE BELOW DUCTWORK, PIPING AND EQUIPMENT AND ASSOCIATED SUPPORTS AND RESTRAINTS. UNLESS OTHERWISE INDICATED, INSTALL TIGHT TO STRUCTURAL SYSTEMS ABOVE. WHERE WALL MOUNTED, INSTALL AS CLOSE TO WALL AS POSSIBLE. PROVIDE ADDITIONAL FITTINGS AND OFFSETS AS REQUIRED. 15. REFER TO EQUIPMENT SCHEDULES FOR DESIGN CAPACITIES. SCHEDULED VALUES SHALL BE CONSIDERED DESIGN CAPACITIES. PROVIDE EQUIPMENT WHICH MEETS OR EXCEEDS THE SCHEDULED VALUES. MARK THE CONTRACT DRAWING EQUIPMENT SCHEDULES TO INDICATE THE MANUFACTURER, MODEL AND CAPACITY OF THE ACTUAL APPROVED EQUIPMENT PROVIDED AND SUBMIT THIS INFORMATION WITH RECORD DRAWINGS AS PART OF PROJECT CLOSEOUT. 16. TO ENHANCE THE CLARITY OF PLAN DRAWINGS, AND WHERE NOT NECESSARY TO DESCRIBE THE REQUIRED SIZE, INDIVIDUAL SEGMENTS OF DUCT AND PIPE BETWEEN CONNECTIONS MAY BE SHOWN WITHOUT A SIZE INDICATED. WHERE SIZE IS NOT SHOWN ON PLANS, THAT SEGMENT SHALL BE THE SAME SIZE AS THE NEXT UPSTREAM SEGMENT WITH A SIZE INDICATED. 17. PROVIDE CONTROL WIRING FOR ALL CONTROL DEVICES ON VRF SYSTEM. ROUTE CONTROL WIRING IN SURFACE METAL RACEWAY PER DIVISION 26 SPECIFICATIONS. 18. PROVIDE DECORATIVE COVER FOR ALL EXPOSED REFRIGERANT AND CONDENSATE PIPING AND INSULATION. PROVIDE PAINTABLE METAL COVER OR PLASTIC COVER. PLASTIC SHALL BE COLOR MATCHED WITH EXISTING PAINT. ON METAL COVER, PROVIDE TWO COATS OF PAINT TO MATCH EXISTING. EQUIPMENT ABBREVIATIONS SHEET TITLE 23 NUMBER OF DETAIL ON SHEET X X THERMOSTAT TS TEMPERATURE SENSOR FLOW SWITCH FOOT/FEET FOOTING FUTURE FACE VELOCITY GAGE/GAUGE GALLON GALVANIZED GENERAL CONTRACTOR GENERAL GALLONS PER HOUR GALLONS PER MINUTE GRADE HEAD HORIZONTAL HORSE POWER HIGH PRESSURE HOUR HEATING HEATER HOT WATER/HEATING WATER HERTZ INCH INLET INSULATION INTERIOR INVERT INCHES WATER GAUGE INTEGRATED PART LOAD VALUE INJECTION PUMP PANEL INDIRECT WASTE JOIST SPACE JOINT KILOWATT KILOWATT HOUR LABORATORY LEAVING AIR TEMPERATURE POUND POUNDS PER HOUR LINEAL FOOT LOCATION LOW PRESSURE LOUVER LEAVING WATER TEMPERATURE MIXED AIR MINIMUM CIRCUIT AMPACITY MANUAL MATERIAL MANUAL AIR VENT MAXIMUM ONE THOUSAND BTU PER HOUR MOTORIZED DAMPER MECHANICAL MANUFACTURER MINIMUM MISCELLANEOUS MOTOR NOT APPLICABLE NOISE CRITERIA NORMALLY CLOSED NOT IN CONTRACT NUMBER NORMALLY OPEN NOMINAL NON-STANDARD PART LOAD VALUE NOT TO SCALE OPPOSED BLADE DAMPER ON CENTER OUTSIDE DIAMETER OPEN DRIP PROOF OVERFLOW OWNER FURNISHED CONTRACTOR INSTALLED OPENING OUTLET VELOCITY PARALLEL BLADE DAMPER woodharbinger.com POINT OF CONNECTION FS FT FTG FUT FV GA GAL GALV GC GEN GPH GPM GR HD HORZ HP HP HR HTG HTR HW DRAWING LIST 425.628.6000 REVISION NUMBER - SHOWN ON PLANS TH TEMPERATURE & HUMIDITY SENSOR GENERAL NOTES: 12 /0 1/ 20 X CARBON DIOXIDE CO2 SENSOR MANUAL SWITCH SW ABBREVIATIONS 929 108th Ave NE Suite 1000 Bellevue WA 98004 PLUMBING AND PIPING SYMBOLS GENERAL MECHANICAL SYMBOLS 1 PROVIDE MINIMUM 36" CLEARANCE FROM NATURAL. GAS METER/CONNECTION. 2 3 5 4 2. PROVIDE NECESSARY CUTTING, PAINTING, PATCHING, ETC., TO FACILITATE MECHANICAL WORK. 3. TAB WORK: PERFORM PRE-CONSTRUCTION TAB OF EXISTING EXHAUST FANS PER SPECIFICATIONS. PERFORM TAB AFTER ALL DUCTWORK HAS BEEN CLEANED PER SPECIFICATIONS. 4. CLEAN ALL EXISTING DUCTWORK AND EXHAUST FANS PER SPECIFICATIONS. 5. PROVIDE COMMISSIONING FOR NEW VRF SYSTEM PER SPECIFICATIONS. SHEET NOTES 1 6" Ø TO WALL CAP PROVIDE MINIMUM 24" CLEARANCE FROM COMB AIR INTAKES. HP-01 (E) NATURAL GAS METER woodharbinger.com COORDINATE ALL SHUTDOWNS WITH OWNER PRIOR TO START OF WORK. 425.628.6000 1. 929 108th Ave NE Suite 1000 Bellevue WA 98004 GENERAL NOTES: PROVIDE Y-BRANCH TO EACH REFRIGERATION LINE 6" Ø TO WALL CAP (E)RFZ 1 A (E)EF-2 12" Ø SA RL / RG CONFERENCE ROOM 014 CONFERENCE ROOM 004 12" Ø SA STORAGE 005 instanceID IFC_UUID C (E)HWP 3" Ø FLUE AND OA FOR B-1 3 4"Ø CD (TYP-4) T IPP T (E)EF-1 (E)RFZ 2 instanceID IFC_UUID (E)RFP EXISTING HW RADIANT HEATER (TYPICAL) (E)DHWH MECH ROOM 003 BC-01 B 4" Ø FLUE DN C RL / RG OPEN OFFICE 001 T (E)B-1 FCU-03 RL / RG (E)RFZ 3 T 4" Ø FLUE UP 3" Ø FLUE UP 3" Ø FLUE UP 6" Ø EA UP TYPICAL HALL 002 (E)EF-4 UNISEX TOILET FCU-01 (E)EF-6 ELEC. COMM. HALL 010 008 T BATHROOMCHINA CAXTON K-20000 VITREOUS SINK RL / RG DN 013 FCU-02 (E) THERMOSTAT (TYP-4) (E)EF-5 JAN. 009 instanceID IFC_UUID T T TEMP SENSOR (TYP-3) (E)EF-3 OFFICE 012 instanceID IFC_UUID C OPEN OFFICE 011 instanceID IFC_UUID D 1 GROUND FLOOR HVAC PLAN IFC_UUID instanceID instanceID IFC_UUID 12 /0 1/ 20 23 1 2. PROVIDE NECESSARY CUTTING, PAINTING, PATCHING, ETC., TO FACILITATE MECHANICAL WORK. 3. TAB WORK: PERFORM PRE-CONSTRUCTION TAB OF EXISTING EXHAUST FANS PER SPECIFICATIONS. PERFORM TAB AFTER ALL DUCTWORK HAS BEEN CLEANED PER SPECIFICATIONS. 4. CLEAN ALL EXISTING DUCTWORK AND EXHAUST FANS PER SPECIFICATIONS. 5. PROVIDE COMMISSIONING FOR NEW VRF SYSTEM PER SPECIFICATIONS. woodharbinger.com COORDINATE ALL SHUTDOWNS WITH OWNER PRIOR TO START OF WORK. 425.628.6000 1. 929 108th Ave NE Suite 1000 Bellevue WA 98004 GENERAL NOTES: SHEET NOTES 1 3 2 5 4 1 PROVIDE TWO CEILING FANS WITH WALL MOUNTED CONTROL PER SPECIFICATION. A OFFICE 101 1 60"Ø CEILING FAN (TYPICAL-2) MAIN HALL 102 CEILING FAN WALL CONTROL SWITCH 6" Ø TO WALL CAP (E)EF-7 (E)EF-12 T B T C ENTRY VESTIBULE 100 4" Ø FLUE UP 3" Ø FLUE UP 3" Ø FLUE UP FCU-05 FCU-04 (E)RFZ 4 3 (E)RFZ 5 JAN. 103 BC-02 3/4"Ø CD (TYP-6) T (E)EF-11 FCU-06 3 (E)EF-15 3 (E)EF-8 T CLOSET 108 FCU-07 A KN NIIH SCMS OUO N0O O R 0E0 TR H 0X TT 2A-IC K B V ELEC / COMM 104 (E)FCU BATHROOMCHINA CAXTON K-20000 VITREOUS SINK 6" Ø UP (TYP 6) 4"Ø CD HALL 107 FCU-08 MEN 105 4"Ø CD (E)EF-9 COPY & SUPPLIES 115 4"Ø CD RL / RG DN T T T HALL 109 (E)EF-13 OPEN OFFICE 114 T T (E)EF-14 OFFICE 113 OPEN OFFICE 110 C LOUNGE 112 D 1 FIRST FLOOR HVAC PLAN WOMEN 106 (E)EF-10 (E)RFZ 6 12 /0 1/ 20 23 6" Ø UP BRANCH CIRCUIT CONTROLLER (BC) ROOM DESIGN CRITERIA HVAC HEAT GAIN [BTUh/PERSON] [2] COOLING SETPOINT (F) RELATIVE HUMIDITY [%] FUME HOOD EXHAUST CFM OCCUPANCY [PEOPLE] PEOPLE/ SF [2] WORKSTATIONS COUNT SENSIBLE EQUIPMENT W/SQFT [W] RECEPTACLE LOAD W/SF [W] LIGHTING[3] W/SF [W] LATENT MAX NOISE DESIGN CRITERIA [2] NC 001 002 003 004 005 006 007 008 009 010 011 012 013 014 100 101 102 103 104 105 106 107 108 109 110 112 113 114 115 815 63 138 385 143 49 184 89 31 85 453 151 13 300 7.75 7.75 7.75 7.75 7.75 7.75 7.75 7.75 7.75 7.75 7.75 7.75 7.75 7.75 8.66 8.66 8.66 8.66 8.66 8.66 8.66 8.66 8.66 8.66 8.66 8.66 8.66 8.66 70 70 70 70 70 70 70 70 70 70 70 70 70 70 75 75 75 75 75 75 75 75 75 75 75 - 75 75 - - 138 75 832 50 64 79 78 103 26 108 408 175 137 367 95 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 75 75 75 75 75 75 75 75 75 75 75 75 75 - 75 75 75 75 - - [7] [12] [1] [7] [1] [8] [1] [7] [1] [3] [4] [1] [3] - 250 250 250 - 200 200 200 - 250 250 250 250 200 200 200 200 250 250 250 250 - 200 200 200 200 - 250 250 250 250 250 LEVEL1 PERFORMANCE HP-01 NOMINAL CAPACITY - TONS HP-01 CAPACITY - MBH INDOOR UNIT'S CAPACITY - MBH NUMBER OF BRANCHES 8 75.6 34.5 8 8 75.6 40.8 8 REFRIGERANT R-410A R-410A 3/8 5/8 1/2 3/8 5/8 1/2 208-1-60 0.8 208-1-60 0.8 DAIKIN BSF8Q54TVJ DAIKIN BSF8Q54TVJ 81.6 81.6 LOCATION NOTES GROUND FLOOR PLAN OPEN OFFICE HALL MECH ROOM CONFERENCE ROOM STORAGE VESTIBULE HALL UNISEX TOILET JANITOR HALL OPEN OFFICE OFFICE ELEC / COMM CONFERENCE ROOM FIRST FLOOR ENTRY VESTIBULE OFFICE MAIN HALL JANITOR ELEC/ COMM MEN WOMEN HALL CLOSET HALL OPEN OFFICE LOUNGE OFFICE OPEN OFFICE COPY / SUPPLIES GROUND LEVEL AREA SERVED 200 200 200 200 200 7 1 1 7 1 8 [xxx] 1 7 1 3 1 3 - [xxx] - - 0.5 0.25 1 0.5 0.25 0.25 0.25 0.25 0.5 0.5 2 0.5 0.66 0.84 0.71 0.66 0.49 0.84 0.84 0.74 0.51 0.84 0.66 0.66 0.71 0.66 45 45 35 45 45 45 45 45 45 45 35 35 0.5 0.5 0.25 2 0.25 0.25 0.25 0.5 2 0.5 0.5 1 0.84 0.66 0.66 0.51 0.71 0.74 0.74 0.84 0.49 0.84 0.66 0.84 0.66 0.66 0.56 45 35 45 45 45 45 45 45 45 45 45 35 45 45 BRANCH PIPE CONNECTIONS LIQUID - IN GAS - IN DISCHARGE - IN [6] SOUND PRESSURE (DBA) ELECTRICAL VOLTS-PHASE-HERTZ MCA [6] STANDARD OF ACCEPTANCE MAKE MODEL MAX. OPERATING WEIGHT-LBS REMARKS [1] [2] [3] NOTES: [1] EQUIPMENT LOAD ON COORDINATION. 5850 W TYPICAL HEAT REJACTION FROM TRANSFORMERS X 3. [2] ASHRAE APLICATIONS 2015 CHAPTER 48 TABLE 1 [3] ASHRAE 90.1 -2022 TABLE 9.5.2.1-1 SPACE BY SPACE LPD… [4] ASHRE 62.1-2022 TABLE 6.1 [5] 2018 INTERNATIONAL MECHANICAL CODE WAC CHAPTER 51-52 [6] THESE ROOM'S ARE EXISTING SPLIT AC SYSTEM 23 HEATING SETPOINT (F) MINIMUM EXHAUST CFM/SF [ACH] [4] AIR COOLED CONDENSING UNITS (HP-01) EQUIPMENT NUMBER EQUIPMENT SERVED HP-01 BC-01 / BC-02 AREA SERVED INDIRECTLY AREA SERVED LOCATION TYPE REFRIGERANT TYPE FCU-01 FCU-02 FCU-03 FCU-04 FCU-05 FCU-06 FCU-07 FCU-08 OPEN OFFICE-001 CONFERENCE-014 OFFICE-012 OPEN OFFICE-011 HALL-010 HALL-002 CONFERENCE-004 VESTIBULE-006 HALL-007 MAIN HALL-102 OFFICE-101 MAIN HALL-102 OPEN OFFICE-114 VESTIBULE-100 HALL-107 OPEN OFFICE-110 LOUNGE-112 HALL-109 OFFICE-113 COPY-115 HALL 002 HALL 010 HALL 002 MAIN HALL 102 MAIN HALL 102 OPEN OFFICE 114 HALL 107 HALL 109 CEILING SUSPENDED CEILING SUSPENDED WALL MOUNTED WALL MOUNTED WALL MOUNTED WALL MOUNTED CEILING SUSPENDED WALL MOUNTED R-410A R-410A R-410A R-410A R-410A R-410A R-410A R-410A 600 710-600 340 410-340 260 300-180 240 300-180 240 300-180 250 300-180 300 710-600 160 300-18 FAN AIRFLOW CFM AIRFLOW RATE CFM COOLING NOMINAL CAPACITY - TON NOMINAL CAPACITY - BTUH TOTAL CAPACITY - BTUH SENS CAPACITY - BTUH EAT-DEG F DB EAT-DEG F WB LAT-DEG F DB 2.0 24000 17000 5700 75 67 55 1.0 12000 8200 3000 75 67 55.3 1.0 12000 9200 2800 75 67 55.70 1.0 12000 7500 2450 75 67 55.40 1.0 12000 7500 2450 75 67 55.40 1.0 12000 11200 4100 75 67 56.70 2.0 24000 11200 4000 75 67 55.60 1.0 12000 3600 1200 75 67 55.50 HEATING NOMINAL CAPACITY - BTUH CAPACITY - BTUH EAT-DEG F DB LAT-DEG F DB 27000 15200 70 88 9000 7600 70 88.1 13500 8600 70 88.5 13500 7600 70 88 13500 7600 70 88 13500 12800 70 88 13500 12800 70 88 13500 4300 70 88 PIPE CONNECTIONS LIQUID - IN GAS - IN CONDENSATE DRAIN - IN BLDG LOCATION FAN COIL UNIT, VRF (FCU'S) EQUIPMENT NUMBER 3/8 5/8 1 1/4 1/2 1 1/4 1/2 2/3 1/4 1/2 2/3 1/4 1/2 2/3 1/4 1/2 2/3 3/8 5/8 1 1/4 1/2 2/3 1 200 1 200 1 200 1 200 31-38 31-38 44 31-38 GROUND LEVEL COMPRESSOR NOMINAL CAPACITY - TONS TOTAL CAPACITY - MBH TOTAL CAPACITY - MBH EER NON- DUCTED IEER NON- DUCTED COP47 NON- DUCTED COP17 NON-DUCTED TEST PROCEDURE 8.0 100 COOL 100 HEAT 15.8 27.8 4.23 2.63 AHRI 1230 REFRIGERANT TYPE FACTORY CHARGE - LBS MAX ADDITIONAL CHARGE - LBS MAX TOTAL CHARGE - LBS R-410A 25.79 14.91 40.7 PIPE CONNECTIONS LIQUID - IN 3/8 3/4 5/8 GAS - IN DISCHARGE - IN SOUND PRESSURE (DBA) 61 ELECTRICAL VOLTS-PHASE-HERTZ MCA MOP 208/3/60 34.1 35 STANDARD OF ACCEPTANCE MAKE MODEL MAX. OPERATING WEIGHT-LBS DAIKIN REYQ96AATJA 725.3 REMARKS [1] PROVIDE WITH MANUFACTURER'S COATING FOR MARINE ENVIRONMENTS. [2] PROVIDE WITH LOW AMBIENT KIT. FILTER FILTER TYPE THICKNESS - INCHES ALLOWANCE FOR DIRTY FILTER -APROX HRS SOUND PRESSURE - dBA 1 200 1 200 1 200 RESIN NET WASHABLE 1 200 44 42 31-38 31-38 PIPING MATERIAL SCHEDULE SERVICE ELECTRICAL VOLTS - PHASE - HERTZ MCA MOCP DESIGN BASIS MAKE MODEL MAX OPERATING WEIGHT-LBS REMARKS. 230-1-60 1.0 15 230-1-60 0.8 15 230-1-60 0.4 15 230-1-60 0.4 15 230-1-60 0.4 15 230-1-60 0.4 15 230-1-60 1.0 15 230-1-60 0.4 15 DAIKIN FXHQ-24MVJU 80 DAIKIN FXHQ-12MVJU 55 DAIKIN FXAQ12PVJU 26.5 DAIKIN FXAQ12PVJU 26.5 DAIKIN FXAQ12PVJU 26.5 DAIKIN FXAQ12PVJU 26.5 DAIKIN FXHQ-24MVJU 80 DAIKIN FXAQ12PVJU 26.5 REFRIGERANT LIQUID (RL) REFRIGERANT SUCTION (RS) CONDENSATE DRAIN woodharbinger.com HEIGHT 425.628.6000 HEIGHT CEILING AREA (SF) BC-02 HP-01 12 /0 1/ 20 ROOM NAME BC-01 HP-01 929 108th Ave NE Suite 1000 Bellevue WA 98004 ROOM TEMPERATURE ROOM NO. EQUIPMENT NUMBER EQUIPMENT SERVED MATERIAL COPPER, ASTM B88 COPPER, ASTM B88 PVC WEIGHT TYPE L TYPE L SCH 40 TYPE HARD DRAWN TUBE HARD DRAWN TUBE TUBE FITTINGS WROUGHT COPPER, ANSI B16.22 WROUGHT COPPER, ANSI B16.22 JOINING METHOD SOLDER, THREADED ADAPTER WITH PTFE TAPE SOLDER, THREADED ADAPTER WITH PTFE TAPE PVC SOLVENT CONNECTIONS E/A BC-02 WALL MOUNTED VRF INDOOR UNIT BC-01 WALL MOUNTED VRF INDOOR UNIT T woodharbinger.com E/A 1. GENERAL: PROVIDE FACTORY CONTROLS FOR VRF SYSTEM. PROVIDE CAPABILITY TO ENABLE/DISABLE TO THE UNIT BASED ON A PROGRAMMABLE SCHEDULE. VENTILATION AIR PROVIDED BY A SEPARATE EXHAUST AIR SYSTEM WHICH IS NOT PART OF THE VRF SYSTEM. VRF FAN COIL UNITS SHALL BE CONTROLLED TO CYCLE WITH LOAD. AN EXISTING HOT WATER RADIANT HEATING SYSTEM IS PROVIDED AND WILL PROVIDE THE BULK OF HEATING. 2. MORNING WARM-UP: THE HOT WATER HEATING SYSTEM WILL PERFORM MORNING WARMUP BASED ON EXISTING LOCAL CONTROL SYSTEM. 3. OCCUPIED MODE: VRF FAN COIL UNIT SHALL USE FACTORY PACKAGED CONTROLS TO SATISFY ROOM TEMPERATURE SETPOINT. PROVIDE HEATING SPACE TEMPERATURE SETPOINT OF 68°F (ADJUSTABLE) AND PROVIDE COOLING SPACE TEMPERATURE SETPOINT OF 76°F (ADJUSTABLE). 4. UNOCCUPIED MODE: DISABLE UNIT VIA SCHEDULE ON FACTORY CONTROLLER. 425.628.6000 TO EXISTING EXHAUST FANS (TYP-16) 929 108th Ave NE Suite 1000 Bellevue WA 98004 SEQUENCE OF OPERATION - VRF OUTDOOR CONDENSER AND INDOOR FAN COIL UNITS. CEILING SPACE LEVEL 1 REF-L REF-S T HP-01 GROUND LEVEL ZONE TEMPERATURE SENSOR, PART OF FACTORY CONTROLS (TYPICAL) VRF OUTDOOR CONDENSER AND INDOOR FAN COIL UNIT (TYPICAL FOR HP-01, AND ACU-01 THROUGH 14) -CONTROL DIAGRAM 1 23 M3.1 M3.2 12 /0 1/ 20 SCALE: N/A