Minimum requirements for project in Dubai Items DWC Trakhees (JAFZA) Dubai DIC Loading code ASCE 7-05 Design Code AISC -2005; British codes are also accepted if required Primary BUS thickness (mm) 6 web 6 flange 6 web 6 flange Endwall BUS thickness (mm) 6 web 6 flange 6 web 6 flange 6 web 6 flange Mezz. Joist & beam BUS thickness (mm) 6 web 6 flange 6 web 6 flange 6 web 6 flange Other BUS thickness 6 web 6 flange 6 web 6 flange 6 web 6 flange Cold formed section thickness As per design As per design As per design Wind speed 3 sec gust 45(m/s) 45(m/s) Min. Load 1 kN/m2 (or) Actual if work out more than 1 kN/m2 for 45 m/s wind load 45(m/s) Wind exposure C C C C Seismic load Zone 2A UBC 1997 Dead + Collateral Load (min) 0.5 kN/m2 0. 5 kN/m2 0.5 kN/m2 0.5 kN/m2 Temperature load difference +/-25°c +/-25°c +/-25°c +/-25°c Mezz floor finish load Customer data Customer data Customer data Customer data Mezz collateral load Customer data Customer data Customer data Customer data Sag rods diameter 12mm 16mm 12mm 12mm No. of sag rods As per Design Purlins for bays less than 9m 200mm depth Minimum Purlins for bays more than 9m 250mm or 300mm depth Minimum Roof bracing type Rod Rod Rod Rod Wall bracing type Rod Angle Rod Rod Type of design LRFD Stress ratio limit 0.90 Primary steel painting customer data 240 microns customer data Purlin design-pattern loading No Yes No No. of anchor bolts Minimum of 4 nos. per column Flange brace thickness 4 mm minimum NOTE: 1. 2. 3. 4. 5. 6. Dubai building code 2021 Edition 3D – Analysis in STAAD is required. Deflection limits should be followed as per Dubai building code 2021 Edition. Kz = 2.3 (or to be calculated as per code) Bolt to bolt distance in connection plates should not be more than 300mm. Wall girt to be considered at base instead of base angle. Steel beam to RCC wall/ column connection should be with chemical bolts instead of anchor bolts. No Minimum requirements for project in Sharjah, Ajman, Umm-al-Quwain, Ras al khaimah Items Hamriya Ajman Sharjah UAQ RAK Loading code ASCE 7-05 Design Code AISC -2005 ; British codes are also accepted if required Primary BUS thickness (mm) 6 web 6 flange 4 web 6 flange Endwall BUS thickness (mm) 6 web 6 flange 4 web 6 flange 4 web 6 flange Mezz. Joist & beam BUS thickness (mm) 6 web 6 flange 4 web 6 flange 4 web 6 flange Other BUS thickness 6 web 6 flange 4 web 6 flange 4 web 6 flange Cold formed section thickness As per design As per design As per design Wind speed 3 sec gust Min. Load 1 kN/m2 (or) Actual if work out more than 1 kN/m2 for 45 m/s wind load 45(m/s) 45(m/s) Wind exposure C Seismic load Zone 2B UBC 1997 Dead + Collateral Load (min) 0.4 kN/m2 Customer data Customer data Customer data Temperature load difference +/-25°c +/-25°c +/-25°c +/-25 °c Mezz floor finish load As per project specification Mezz collateral load As per project specification Sag rods diameter 12mm 12mm 12mm 12mm No. of sag rods As per Design Roof bracing type Rod Rod Rod Rod Wall bracing type Rod Rod Rod Rod Type of design LRFD LRFD Stress ratio limit 0.95 Primary steel painting Customer requirement No. of anchor bolts Minimum of 4 nos. per column Flange brace thickness 4 mm minimum NOTE: 1. 2. 3. 4. 5. 6. 7. ASCE 7-05 45(m/s) Zone 2A UBC 1997 3D – Analysis in STAAD is required, MBS can be used for box buildings in RAK & Sharjah only. Deflection limits should be followed as per AISC -2005 & ASCE 7-05. Kz = 2.3 (or to be calculated as per code) For UAQ Municipality, maximum Purlin & Girt Spacing should not Exceed 1.2M (Civil Defense Requirement) Bolt to bolt distance in connection plates should not be more than 300mm. Wall girt to be considered at base instead of base angle. Steel beam to RCC wall/ column connection should be with chemical bolts instead of anchor bolts. Minimum requirements for project in Abudhabi, Al Ain, Western Region(WRM) & CMW Items Abudhabi Al Ain WRM CWM Loading code Abudhabi Building Code (ADIBC) Design Code AISC -2005 Primary BUS thickness (mm) 5 web 6 flange 5 web 6 flange 6 web 6 flange 6 web 8 flange Double side weld Endwall BUS thickness (mm) 5 web 6 flange 5 web 6 flange 6 web 6 flange 6 web 8 flange Mezz. Joist & beam BUS thickness (mm) 5 web 6 flange 5 web 6 flange 6 web 6 flange 6 web 8 flange Other BUS thickness 5 web 6 flange 5 web 6 flange 6 web 6 flange 6 web 8 flange Purlin CRFS thickness 2mm 2mm 2.5mm Girt CRFS thickness As per design As per design 2.5mm Wind speed 3 sec gust 45 m/s Wind exposure C IBC 2009 ; Site class B, Ss=0.65, S1=0.195, TL=8 For WRM: occupancy category 4 ; site class D, stiff soil, Ss=0.45,S1=0.14, Importance factor I=1.5;TL=8 Seismic load Collateral load on roof (min) Customer data Live load on purlins 1.0 KN/m2 Temperature load difference +/-35°c Mezz floor finish load As per project specification Sag rods diameter No. of sag rods Roof bracing type +/-35°c +/-35°c +/-35°c 12mm As per Design Rod 12mm 12mm 12mm Rod Rod Angle Wall bracing type Rod Rod Rod Angle Type of design LRFD Stress ratio limit 0.95 for primary steel Primary steel painting Customer requirement except in CMS where 240 microns epoxy paint No. of anchor bolts No restriction except CMS & WRM where 8.8 grade is required. Flange brace thickness 4 mm minimum; In CMW jobs flange brace should be 5mm min. In others word the restrains for the bottom flange should not be taken less than 5m. Minimum thickness of gusset plates, packing plates & splicing plates in WRM & CMW is 10mm. NOTE: 1. 2. 3. 4. 5. 6. 3D – Analysis in STAAD is required. Deflection limits should be followed as per Abudhabi Building Code (ADIBC). Kz = 2.3 (or to be calculated as per code) Bolt to bolt distance in connection plates should not be more than 300mm. Wall girt to be considered at base instead of base angle. Steel beam to RCC wall/ column connection should be with chemical bolts instead of anchor bolts. Special consideration for projects with Capital Consultant ➢ ➢ ➢ ➢ ➢ Minimum plate thickness for Web must be 5mm. Strut tubes must be provided on Eave at Braced Bay locations. Strut purlins in End bays & in Braced bays along wind column locations. 8.8 Grade Anchor bolts must be used. Minimum 500mm Embedment length for Anchor bolts.