Vipros 2510 With Fanuc 18P Control Layout Drawings ©Amada America Inc. Vipros 2510 With Fanuc 18P Control Layout Drawings Amada America Inc. 7025 Firestone Blvd. Buena Park CA. 90621 Phone: (714) 739 2111 Fax.: (714) 739 4099 Email info@amada.com Print Date 01/17/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 1 of 10 Vipros 2510 With Fanuc 18P Control Layout Drawings ©Amada America Inc. Warning ! Qualified personnel must complete all work. ! Do not apply power to the Vipros 2510 until an A.E.S.I. (Amada Engineering and Service Incorporated) Engineer is present and has instructed you to do so. ! Not all information required to install the Vipros 2510 is included with this document. Specific details for proper installation are found in the document Vipros 2510 With 18P Control Pre-installation Guide available at the Amada America Internet web site at http://www.amada.com/. ! Considerable effort has been made to ensure that this manual is free of inaccuracies and omissions. However, as we are constantly improving our product, some of the data contained herein may be out of date. Please check our Internet site, http://www.amada.com/, for the latest release of this document. Print Date 01/17/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 2 of 10 Vipros 2510 With Fanuc 18P Control Layout Drawings ©Amada America Inc. Contents Planning the Location of the Vipros 2510 ......................................................................................................... 4 Plan View - Vipros 2510 King........................................................................................................................ 5 Plan View - Vipros 2510 King (shown with optional V255hs Conveyor) ........................................................ 6 Plan View - Vipros 2510 King (shown with optional V255hs Conveyor and MP1225 Loader) ....................... 7 End View - Vipros 2510 King......................................................................................................................... 8 Elevation View - Vipros 2510 King ................................................................................................................ 9 Chiller Placement ........................................................................................................................................ 10 Print Date 01/17/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 3 of 10 Vipros 2510 With Fanuc 18P Control Layout Drawings ©Amada America Inc. Planning the Location of the Vipros 2510 The following diagrams provide the details for positioning the Vipros 2510. " No obstacles are allowed in the worksheet travel area and the ceiling must be at least 40" above the Vipros 2510. " All of the recommended maintenance areas should be used, but at a minimum the doors of the NC unit must be able to be opened. Any reduction of the listed maintenance areas may increase time and expense of installation and maintenance. " The Vipros 2510 machine and control must be protected from direct sunlight or other heat sources. Direct exposure to direct heating sources such as infrared heaters have been shown to affect punch and die alignment. " The positioning of the SBC EX3.0 Chiller is very flexible Print Date 01/17/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 4 of 10 Vipros 2510 With Fanuc 18P Control Layout Drawings ©Amada America Inc. Plan View - Vipros 2510 King Electrical Requirements E1 Vipros 2510 King 230 / 460 / 3 / 60 ±10%, 22 kVA 56 amps @ 230 / 3 / 60 VAC 28 amps @ 460 / 3 / 60 VAC E2 SBC EX3.0 Chiller 230 or 460 / 3 / 60 ±10%, 15 kVA 38 amps @ 230 / 3 / 60 VAC 19 amps @ 460 / 3 / 60 VAC 57" 37" Chiller Unit (Actual location variable) Compressed Air Requirements P1 Vipros 2510 80 psi @ 8.8 ft3/min. E2 2 40" Vipros 2510 King Optional Material Support Required 50" Work Area 208" Machine length Y-axis 0" 100" Maximum travel area 50" material 338" Recommended Safety / Maintenance area 40" from all components Operator Control Station Track 200 Punch Center Hydraulic Unit Optional Material Support Required P1 E1 Vipros 2510 Centerline 12" 12" 12" Scale 98.425" to X axis origin 101" to edge of table 202" Machine Width 393.70" Maximum Travel Area 196.85" Material 474" Recomended Safety / Maintenance Area 40" from all components Print Date 01/17/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 5 of 10 Vipros 2510 With Fanuc 18P Control Layout Drawings ©Amada America Inc. Plan View - Vipros 2510 King (shown with optional V255hs Conveyor) Electrical Requirements E1 Vipros 2510 King 230 / 460 / 3 / 60 ±10%, 22 kVA 56 amps @ 230 / 3 / 60 VAC 28 amps @ 460 / 3 / 60 VAC Access required this area for slug removal 45" 57" E3 V255hs Conveyor 208 - 230 / 460 / 3 / 60 ±10%, .8 kVA 2.1 amps @ 208 / 3 / 60 VAC 2.0 amps @ 230 / 3 / 60 VAC 1.0 amps @ 460 / 3 / 60 VAC 51" 37" Chiller Unit (Actual location variable) E2 2 E3 3 V255hs Conveyor E2 SBC EX3.0 Chiller 230 or 460 / 3 / 60 ±10%, 15 kVA 38 amps @ 230 / 3 / 60 VAC 19 amps @ 460 / 3 / 60 VAC 40" Vipros 2510 King Y-axis 0" Optional Material Support Required 50" Work Area 208" Machine length 80 psi @ 8.8 ft3/min. 100" Maximum travel area 50" material P1 Vipros 2510 Operator Control Station 338" Recommended Safety / Maintenance area 40" from all components Compressed Air Requirements Track 200 Punch Center Hydraulic Unit Optional Material Support Required P1 E1 Vipros 2510 Centerline 12" 12" 12" Scale 98.425" to X axis origin 101" to edge of table 202" Machine Width 393.70" Maximum Travel Area 196.85" Material 474" Recomended Safety / Maintenance Area 40" from all components Print Date 01/17/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 6 of 10 Vipros 2510 With Fanuc 18P Control Layout Drawings ©Amada America Inc. Plan View - Vipros 2510 King (shown with optional V255hs Conveyor and MP1225 Loader) Electrical Requirements E1 Vipros 2510 King 230 / 460 / 3 / 60 ±10%, 22 kVA 56 amps @ 230 / 3 / 60 VAC 28 amps @ 460 / 3 / 60 VAC Access required this area for slug removal 40" 68" Y-axis 0" 190" Loader Length Optional Material Support Required Track 200 Punch Center 122" 75 psi @ 31.8 ft3/min. E4 P2 50" Work Area P2 MP1225 Loader Operator Control Station Xformer MP1225 Vipros 2510 King 208" Machine length 80 psi @ 8.8 ft3/min. 100" Maximum travel area 50" material P1 Vipros 2510 E2 2 E3 3 338" Recommended Safety / Maintenance area 40" from all components Compressed Air Requirements 51" 37" E3 V255hs Conveyor 208 - 230 / 460 / 3 / 60 ±10%, .8 kVA 2.1 amps @ 208 / 3 / 60 VAC 2.0 amps @ 230 / 3 / 60 VAC 1.0 amps @ 460 / 3 / 60 VAC E4 MP1225 Loader 200 / 3 / 60 ±10%, 10 Kva To operate at 230 / 460 VAC a step up transformer is required with the following service is required 29 amps @ 200 / 3 / 60 VAC 26 amps @ 230 / 3 / 60 VAC 13 amps @ 460 / 3 / 60 VAC 45" 57" Chiller Unit (Actual location variable) V255hs Conveyor E2 SBC EX3.0 Chiller 230 or 460 / 3 / 60 ±10%, 15 kVA 38 amps @ 230 / 3 / 60 VAC 19 amps @ 460 / 3 / 60 VAC Hydraulic Unit Optional Material Support Required P1 MP1225 Loader Access for material loading / unloading required in this area Vipros 2510 Centerline E1 142" Loader Width 12" 98.425" to X axis origin 101" to edge of table 102" to edge of Loader 244" to edge of Loader 12" 12" Scale 202" Machine Width 393.70" Maximum Travel Area 196.85" Material 344" Vipros 2510 King MP1225 assembly width 520" Recomended Safety / Maintenance Area 40" from all components Print Date 01/17/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 7 of 10 Vipros 2510 With Fanuc 18P Control Layout Drawings ©Amada America Inc. End View - Vipros 2510 King 201.60" 100.80" 100.80" Table in Shipping Position Material Pass Line* 29.53" 19.67" 126.00" Shipping Width Floor Line 12" 12" 12" Scale *Material Pass Line varies between 37.20" and 40.95" as a function of machine mounting method and installed options Print Date 01/17/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 8 of 10 Vipros 2510 With Fanuc 18P Control Layout Drawings ©Amada America Inc. Elevation View - Vipros 2510 King Throat Depth 17.33" Punch Center Turret Center 52.13" 10.60" Y-Axis Load Position 50.00" 15.93" 33.27" 80.00" 86.33" Material Pass Line* Floor Line 17.93" 8.08" 26.53" 115.60" 26.53" 13.80" 12" 12" 12" Scale 168.67" 208.27" *Material Pass Line varies between 37.20" and 40.95" as a function of machine mounting method and installed options Print Date 01/17/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 9 of 10 Vipros 2510 With Fanuc 18P Control Layout Drawings ©Amada America Inc. Chiller Placement 6" 48.87" The Chiller Location is flexible and position shown is for reference only. Under normal operation the chiller may be placed against walls as shown. For maintenance access to all sides may be required. Air Flow 36.90" 6" Electrical Power 15 Kva Supplied 15 ft Water Hose Operator Panel Print Date 01/17/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 10 of 10