Uploaded by havec80049

Vipros 2510 Layout Drawings

advertisement
Vipros 2510 With Fanuc 18P Control Layout Drawings
©Amada America Inc.
Vipros 2510 With Fanuc 18P Control
Layout Drawings
Amada America Inc.
7025 Firestone Blvd.
Buena Park CA. 90621
Phone: (714) 739 2111
Fax.: (714) 739 4099
Email info@amada.com
Print Date 01/17/2001 Revision 4.0
This document available on the World Wide Web at http://www.amada.com
Page 1 of 10
Vipros 2510 With Fanuc 18P Control Layout Drawings
©Amada America Inc.
Warning
! Qualified personnel must complete all work.
! Do not apply power to the Vipros 2510 until an A.E.S.I. (Amada Engineering and
Service Incorporated) Engineer is present and has instructed you to do so.
! Not all information required to install the Vipros 2510 is included with this document.
Specific details for proper installation are found in the document Vipros 2510 With
18P Control Pre-installation Guide available at the Amada America Internet web site
at http://www.amada.com/.
! Considerable effort has been made to ensure that this manual is free of
inaccuracies and omissions. However, as we are constantly improving our product,
some of the data contained herein may be out of date. Please check our Internet
site, http://www.amada.com/, for the latest release of this document.
Print Date 01/17/2001 Revision 4.0
This document available on the World Wide Web at http://www.amada.com
Page 2 of 10
Vipros 2510 With Fanuc 18P Control Layout Drawings
©Amada America Inc.
Contents
Planning the Location of the Vipros 2510 ......................................................................................................... 4
Plan View - Vipros 2510 King........................................................................................................................ 5
Plan View - Vipros 2510 King (shown with optional V255hs Conveyor) ........................................................ 6
Plan View - Vipros 2510 King (shown with optional V255hs Conveyor and MP1225 Loader) ....................... 7
End View - Vipros 2510 King......................................................................................................................... 8
Elevation View - Vipros 2510 King ................................................................................................................ 9
Chiller Placement ........................................................................................................................................ 10
Print Date 01/17/2001 Revision 4.0
This document available on the World Wide Web at http://www.amada.com
Page 3 of 10
Vipros 2510 With Fanuc 18P Control Layout Drawings
©Amada America Inc.
Planning the Location of the Vipros 2510
The following diagrams provide the details for positioning the Vipros 2510.
" No obstacles are allowed in the worksheet travel area and the ceiling must be at least 40" above the Vipros 2510.
" All of the recommended maintenance areas should be used, but at a minimum the doors of the NC unit must be able to be
opened. Any reduction of the listed maintenance areas may increase time and expense of installation and maintenance.
" The Vipros 2510 machine and control must be protected from direct sunlight or other heat sources. Direct exposure to direct
heating sources such as infrared heaters have been shown to affect punch and die alignment.
" The positioning of the SBC EX3.0 Chiller is very flexible
Print Date 01/17/2001 Revision 4.0
This document available on the World Wide Web at http://www.amada.com
Page 4 of 10
Vipros 2510 With Fanuc 18P Control Layout Drawings
©Amada America Inc.
Plan View - Vipros 2510 King
Electrical Requirements
E1 Vipros 2510 King
230 / 460 / 3 / 60 ±10%, 22 kVA
56 amps @ 230 / 3 / 60 VAC
28 amps @ 460 / 3 / 60 VAC
E2 SBC EX3.0 Chiller
230 or 460 / 3 / 60 ±10%, 15 kVA
38 amps @ 230 / 3 / 60 VAC
19 amps @ 460 / 3 / 60 VAC
57"
37"
Chiller Unit
(Actual location variable)
Compressed Air Requirements
P1 Vipros 2510
80 psi @ 8.8 ft3/min.
E2
2
40"
Vipros 2510 King
Optional Material
Support Required
50" Work Area
208" Machine length
Y-axis 0"
100" Maximum travel area 50" material
338" Recommended Safety / Maintenance area 40" from all components
Operator Control Station
Track 200
Punch Center
Hydraulic
Unit
Optional Material
Support Required
P1
E1
Vipros 2510
Centerline
12"
12"
12"
Scale
98.425" to X axis origin
101" to edge of table
202" Machine Width
393.70" Maximum Travel Area 196.85" Material
474" Recomended Safety / Maintenance Area 40" from all components
Print Date 01/17/2001 Revision 4.0
This document available on the World Wide Web at http://www.amada.com
Page 5 of 10
Vipros 2510 With Fanuc 18P Control Layout Drawings
©Amada America Inc.
Plan View - Vipros 2510 King (shown with optional V255hs Conveyor)
Electrical Requirements
E1 Vipros 2510 King
230 / 460 / 3 / 60 ±10%, 22 kVA
56 amps @ 230 / 3 / 60 VAC
28 amps @ 460 / 3 / 60 VAC
Access required this
area for slug removal
45"
57"
E3 V255hs Conveyor
208 - 230 / 460 / 3 / 60 ±10%, .8 kVA
2.1 amps @ 208 / 3 / 60 VAC
2.0 amps @ 230 / 3 / 60 VAC
1.0 amps @ 460 / 3 / 60 VAC
51"
37"
Chiller Unit
(Actual location variable)
E2
2
E3
3
V255hs Conveyor
E2 SBC EX3.0 Chiller
230 or 460 / 3 / 60 ±10%, 15 kVA
38 amps @ 230 / 3 / 60 VAC
19 amps @ 460 / 3 / 60 VAC
40"
Vipros 2510 King
Y-axis 0"
Optional Material
Support Required
50" Work Area
208" Machine length
80 psi @ 8.8 ft3/min.
100" Maximum travel area 50" material
P1 Vipros 2510
Operator Control Station
338" Recommended Safety / Maintenance area 40" from all components
Compressed Air Requirements
Track 200
Punch Center
Hydraulic
Unit
Optional Material
Support Required
P1
E1
Vipros 2510
Centerline
12"
12"
12"
Scale
98.425" to X axis origin
101" to edge of table
202" Machine Width
393.70" Maximum Travel Area 196.85" Material
474" Recomended Safety / Maintenance Area 40" from all components
Print Date 01/17/2001 Revision 4.0
This document available on the World Wide Web at http://www.amada.com
Page 6 of 10
Vipros 2510 With Fanuc 18P Control Layout Drawings
©Amada America Inc.
Plan View - Vipros 2510 King (shown with optional V255hs Conveyor and MP1225 Loader)
Electrical Requirements
E1 Vipros 2510 King
230 / 460 / 3 / 60 ±10%, 22 kVA
56 amps @ 230 / 3 / 60 VAC
28 amps @ 460 / 3 / 60 VAC
Access required this
area for slug removal
40"
68"
Y-axis 0"
190" Loader Length
Optional Material
Support Required
Track 200
Punch Center
122"
75 psi @ 31.8 ft3/min.
E4
P2
50" Work Area
P2 MP1225 Loader
Operator Control Station
Xformer
MP1225
Vipros 2510 King
208" Machine length
80 psi @ 8.8 ft3/min.
100" Maximum travel area 50" material
P1 Vipros 2510
E2
2
E3
3
338" Recommended Safety / Maintenance area 40" from all components
Compressed Air Requirements
51"
37"
E3 V255hs Conveyor
208 - 230 / 460 / 3 / 60 ±10%, .8 kVA
2.1 amps @ 208 / 3 / 60 VAC
2.0 amps @ 230 / 3 / 60 VAC
1.0 amps @ 460 / 3 / 60 VAC
E4 MP1225 Loader
200 / 3 / 60 ±10%, 10 Kva
To operate at 230 / 460 VAC a step up
transformer is required with the following
service is required
29 amps @ 200 / 3 / 60 VAC
26 amps @ 230 / 3 / 60 VAC
13 amps @ 460 / 3 / 60 VAC
45"
57"
Chiller Unit
(Actual location variable)
V255hs Conveyor
E2 SBC EX3.0 Chiller
230 or 460 / 3 / 60 ±10%, 15 kVA
38 amps @ 230 / 3 / 60 VAC
19 amps @ 460 / 3 / 60 VAC
Hydraulic
Unit
Optional Material
Support Required
P1
MP1225 Loader
Access for
material loading / unloading
required in this area
Vipros 2510
Centerline
E1
142" Loader Width
12"
98.425" to X axis origin
101" to edge of table
102" to edge of Loader
244" to edge of Loader
12"
12"
Scale
202" Machine Width
393.70" Maximum Travel Area 196.85" Material
344" Vipros 2510 King MP1225 assembly width
520" Recomended Safety / Maintenance Area 40" from all components
Print Date 01/17/2001 Revision 4.0
This document available on the World Wide Web at http://www.amada.com
Page 7 of 10
Vipros 2510 With Fanuc 18P Control Layout Drawings
©Amada America Inc.
End View - Vipros 2510 King
201.60"
100.80"
100.80"
Table in
Shipping Position
Material
Pass Line*
29.53"
19.67"
126.00" Shipping Width
Floor Line
12" 12" 12"
Scale
*Material Pass Line varies between
37.20" and 40.95" as a function of
machine mounting method and
installed options
Print Date 01/17/2001 Revision 4.0
This document available on the World Wide Web at http://www.amada.com
Page 8 of 10
Vipros 2510 With Fanuc 18P Control Layout Drawings
©Amada America Inc.
Elevation View - Vipros 2510 King
Throat
Depth
17.33"
Punch
Center
Turret
Center
52.13"
10.60"
Y-Axis
Load
Position
50.00"
15.93"
33.27"
80.00"
86.33"
Material
Pass Line*
Floor Line
17.93"
8.08"
26.53"
115.60"
26.53"
13.80"
12" 12" 12"
Scale
168.67"
208.27"
*Material Pass Line varies between
37.20" and 40.95" as a function of machine
mounting method and installed options
Print Date 01/17/2001 Revision 4.0
This document available on the World Wide Web at http://www.amada.com
Page 9 of 10
Vipros 2510 With Fanuc 18P Control Layout Drawings
©Amada America Inc.
Chiller Placement
6"
48.87"
The Chiller Location is flexible and position shown is for
reference only.
Under normal operation the chiller may be placed against
walls as shown. For maintenance access to all sides may be required.
Air
Flow
36.90"
6"
Electrical Power
15 Kva
Supplied 15 ft
Water Hose
Operator Panel
Print Date 01/17/2001 Revision 4.0
This document available on the World Wide Web at http://www.amada.com
Page 10 of 10
Download