Preconfigured Model PAS50C - Acoustical Door System
STC 50 (3’0” x 7’0” Flush Singles)
1 3/4" Acoustical Door System
with Compression Seals
2”
1/2
14 GA. ACOUSTICAL FRAME
(GROUTING OF FRAME
BY OTHERS)
RIVET NUT
1/2
SPECIFICATIONS
1) All exposed surfaces of door and frame to receive one coat of rust inhibitive prime
paint complying with ASTM A250.10.
2) An aluminum threshold is included. Threshold must protrude 1 1/2" inches past the
face of the frame on the pull side of the door to allow the EPDM rubber section of the
door bottom to seat properly during normal operation of the cam-lift hinges.
3) Door bottom requires a flush level sealing surface. The threshold must be level and
may require shimming to compensate for an uneven floor. This will prevent any sound
leaks at this location. Threshold to be grouted solid.
4)
1 1/8
RUBBER
EPDM SEAL
SEAL RETAINER
RETAINER COVER
ACOUSTICAL DOOR
PULL SIDE
OF DOOR
1/4-20 HH BOLTS @ PRE-DRILLED LOC.
PROVIDES 3/8" ADJUSTMENT
7/8" UNDERCUT
L-FRAME ADJUSTABLE DOOR BOTTOM
1 1/2" MINIMUM
5)
Assembly is equipped with metal acoustical door, frame, seals, door bottom,
threshold, cam-lift hinges and crated for shipment.
TOP INVERTED CHANNEL
WITH TOP CAP
DOOR CONSTRUCTION
THROAT
1/2"
Door Thickness is 1 3/4". Door weight is 11.9 pounds per square foot. Be aware that
the frame must be securely tied to the framing from the sub floor to the structure
above. Doubled wood studs or 16 Ga. steel studs are strongly recommended to
support the weight of the assembly.
6)
Doors are to be formed of 16 Gauge steel face sheets welded
at the vertical edges and finished smooth.
7)
Frames are to be formed of 14 Gauge sheet steel with corners mitered,
continuously welded and ground smooth.
8)
Doors and frames are formed from commercial quality zinc coated steel conforming
to ASTM A653 & ASTM A924. Acoustical core and internal construction are
manufacturer's proprietary standards as tested in accordance with ASTM E90, E413,
E1332, & E2235.
1/2"
2"
1 1/8"
6-3/8", 7-5/8”, 8-3/8” OR 9-5/8”
JAMB DEPTHS
CORNERS: CONTINUOUSLY WELDED
AVAILABLE IN 14 GAUGE
ADJ PROFILE
10) Please be aware industry standard construction tolerances for squareness of frame
7"
1/2" FLAT UNFLUTED
THRESHOLD
VERTICAL SECTION
installation, plumbness of walls, flatness of floors, etc. may result in a difference of
3db-5db sound loss in a field test vs. lab results.
11) Frame must be fully grouted to ensure maximum acoustical performance.
As an alternative, 10# density mineral wool insulation can be used
7 GAUGE
REINFORCEMENT
CAM-LIFT HINGE
12) Fire Rated up to 90 minutes.
MODEL PAS50C UTILIZES
"ADJ" PROFILE FRAME
13) 3’0” x 7’0” single.
HINGE PREPARATION
(HINGES ARE HANDED)
SURFACE MOUNTED
CLOSER REINFORCEMENT
REVOLUTIONARY SOUND
ABSORPTION CORE
For any variable outside of that shown here,
please reference the Custom Quick Cut Sheets.
ADJUSTABLE "L" FRAME ™
PROVIDES 3/8"
ADJUSTMENT
PULL SIDE
OF DOOR
FOAM SPACER
.
DOOR AND FRAME PREPARED FOR:
HINGES:
CAM-LIFT HINGES PROVIDED
WITH DOOR AND FRAME
LOCK:
CYLINDRICAL LOCK ANSI A115.2 WITH
3-3/4" BACKSET (BY OTHERS)
FINISH:
STANDARD PRIMER PAINT; TESTED IN CONFORMANCE WITH ANSI A250.10
.
DOOR SYSTEM TESTED IN CONFORMANCE WITH ASTM E2235, ASTM E1332
ACOUSTICAL
ASTM E90 & E413, FULLY OPERABLE, STC AS NOTED ABOVE.
PERFORMANCE
DOOR SYSTEMS ARE IN COMPLIANCE WITH HMMA 865 & SDI-128 SPECIFICATIONS.
EPDM RUBBER SEAL
ATTACHED WITH ADHESIVE
DOOR BOTTOM CONSTRUCTION
SURFACE APPLIED
BOTTOM SOUND SEAL
1224
Preconfigured Model PAS50A - Acoustical Door System
S88
STC 50 (3’0” x 7’0” Flush Singles)
1 3/4" Acoustical Door System
with Adhesive Seals
S44
SPECIFICATIONS
1) All exposed surfaces of door and frame to receive one coat of rust inhibitive prime
paint complying with ASTM A250.10.
2) An aluminum threshold is included.
PEMKO S44 SEAL
2”
4) Assembly is equipped with metal acoustical door, frame, seals and threshold. Product is
also crated for shipment.
5) Door Thickness is 1 3/4". Door weight is 11.9 pounds per square foot. Be aware that
the frame must be securely tied to the framing from the sub floor to the structure above.
14 GA. ACOUSTICAL FRAME
(GROUTING OF FRAME
BY OTHERS)
ACOUSTICAL DOOR
2 ROWS PEMKO S771 SEAL
THRESHOLD
PEMKO 2009APK
VERTICAL SECTION
6) Doors are to be formed of 16 Gauge steel face sheets with welded smooth edge
at the vertical edges and finished smooth.
2009APK
THRESHOLD INCLUDED
HINGE / STRIKE JAMB
1/2"
2"
THROAT
1/2"
5/8"
7) Frames are to be formed of 14 Gauge sheet steel with corners mitered,
continuously welded and ground smooth.
8) Doors and frames are formed from commercial quality cold rolled steel with optional
zinc coating conforming to ASTM A653 & ASTM A924. Acoustical core and internal
construction are manufacturer's proprietary standards as tested in accordance with
ASTM E90, E413, E1332, & E2235.
9) Frame must be fully grouted to ensure maximum acoustical performance.
As an alternative, 10# density mineral wool insulation can be used.
10) Please be aware industry standard construction tolerances for squareness of frame
installation, plumbness of walls, flatness of floors, etc. may result in a difference of
3db-5db sound loss in a field test vs. lab results.
11) Alternate seal sets may be supplied based on function of hardware.
12) Fire Rated up to 90 minutes.
MODEL PAS50A UTILIZES
"S" PROFILE FRAME
ACP112
CORNER PAD
TRIM TO FIT
3) Bottom seals require a flush level sealing surface. The threshold must be level and may
require shimming to compensate for an uneven floor. This will prevent any sound leaks
at this location.
Pemko S773 Seal
PEMKO S88 SEAL
S773
6-3/8", 7-5/8”, 8-3/8” OR 9-5/8”
JAMB DEPTHS
ACOUSTICAL FRAME PROFILE
7 GAUGE REINFORCEMENT
5" HEAVY WEIGHT
HINGES
ANSI A156.7
13) 3’0” x 7’0” single.
SURFACE MOUNTED
CLOSER REINFORCEMENT
For any variable outside of that shown here,
please reference the Custom Quick Cut Sheets.
ACOUSTICAL
PERFORMANCE
DOOR AND FRAME PREPARED FOR:
HINGES:
5” HEAVY WEIGHT HINGES ANSI A156.7 (BY OTHERS)
LOCK:
CYLINDRICAL LOCK ANSI A115.2 WITH
2-3/4" BACKSET (BY OTHERS)
.
STANDARD PRIMER PAINT; TESTED IN CONFORMANCE WITH ANSI A250.10
TESTED AND IN COMPLIANCE WITH ASTM E90, ASTM E413, ASTM E1332, & ASTM E2235.
DOOR SYSTEMS ARE IN COMPLIANCE WITH HMMA 865 & SDI-128 SPECIFICATIONS.
COMPLETE WITH PERIMETER SOUND SEALS, BOTTOM SEALS AND THRESHOLD
AS REQUIRED FOR RATING.
(HINGES ARE HANDED)
REVOLUTIONARY SOUND
ABSORPTION CORE
.
FINISH:
HINGE PREPARATION
DOOR CONSTRUCTION
TOP AND BOTTOM
2009APK
THRESHOLD INCLUDED
1224
Acoustical Perimeter Seals
Adhesive vs Compression
Adhesive Seals
Compression Seals
• Achieves up to STC 52 - 1-3/4” thick doors
(STC 55 - 2-1/2” thick)
• Achieves up to STC 54 - 1-3/4” thick doors
(STC 66 communicating door)
• Limited field adjustability after application
• Adjustability to accommodate field
conditions
• Standard frame can be utilized
• Seal modification (or reapplication)
is sometimes needed in the field to
accommodate certain hardware
(electric strikes)
• Requires custom acoustical frame
• Easy to install
• Requires higher level of installation
knowledge
• GreenGuard certified
• Meets ADA requirements
• Matches competition on high end
STC assemblies
Ceco Door
9159 Telecom Drive • Milan, TN 38358
Tel (888) 232-6366 • Fax (888) 232-6462
archhelp@cecodoor.com | www.cecodoor.com
Ceco is a brand associated with AADG, Inc., an ASSA ABLOY Group company.
Copyright © 2017, AADG, Inc. All rights reserved. Reproduction in whole or in
part without the express written permission of AADG, Inc. is prohibited.
Download