1. UPS5000 -A 30~120kVA can support wall installation.
A. True
B. False
Answer: B
2. UPS2000-G monitors the entire parallel system with one card. The parallel system only needs one
communication option card to monitor the entire parallel system.
A. True
B. False
Answer: A
3. FusionModule1000A V2R3 version uses Huawei UPS5000E as IT load power supply
A. True
B. False
Answer: B
4. Fire extinguishing measures that can be adopted in Class A computer rooms include ()
A. Gas fire extinguishing system
B. Water mist fire extinguishing system
C. Automatic sprinkler system
D. All of the above
Answer: A
5. The water inlet slope of the fan coil condensate tray should be no less than?
A. 0.01
B. 0.02
C. 0.05
D. 0.1
Answer: A
6.FusionModule2000 integrated UPS has two models: 50K/125K.
A. True
B. False
Answer: A
7.UPS2000-G adopts high power density design, 6k/10k is only 2U high, 15K/20K is only 3U high,
reducing installation space.
A. True
B. False
Answer: A
8.The UPS5000-E power module adopts a fan fault-tolerant design. When two of the fans fail, how much
load can the power module still carry?
A. 0.2
2two​
NUMPAGES
Download valid H19-105_V2.0-ENU exam dumps for best preparation
B. 0.3
C. 0.5
D. 0.6
Answer: B
9.What is the total IT load power of the FusionModule1000A V2R3 version 40-foot IT solution?
A. 52kW
B. 55kW
C. 70kW
D. 72kW
Answer: A
10. The EC fan brand used in the NetCol5000-A025H half-cabinet row-level variable-frequency air-cooled
precision air-conditioning indoor unit is Xerox Bai.
A. True
B. False
Answer: B
11. Three-proof paint coating can significantly reduce the failure rate of UPS in harsh environments such
as salt spray, dust, high temperature and humidity, ensuring its service life in harsh environments.
A. True
B. False
Answer: A
12.FusionModule1000A V2R3 version 40-foot CT solution can install 8 CT cabinets
A. True
B. False
Answer: A
13. Which of the following models can be equipped with an external large-capacity battery charger for fast
recharging?
A. UPS5000-A
B. UPS5000-E
C. UPS2000-A 6/10K Professional Edition Standard
D. UPS2000-G 6K long-term
Answer: C
14. The basic principles of refrigeration for air-cooled and water-cooled air conditioners are the same
A. True
B. False
Answer: A
15. The fans of NetCol5000-C030H row-level chilled water precision air conditioners can be maintained
online, and a separate power-off switch can be provided for each fan to avoid safety hazards caused by
3two​
NUMPAGES
Download valid H19-105_V2.0-ENU exam dumps for best preparation
direct live maintenance.
A. True
B. False
Answer: A
16.UPS5000-E (50kVA power module) has a single cabinet capacity of 300kVA and can support 8 racks in
parallel.
A. True
B. False
Answer: A
17. In FusionModule2000, when the columns occupy the closed channel space in the column-surrounding
scene, how should the skylight be adapted?
A. Custom tempered glass flip skylight
B. On-site processing with control skylight
C. On-site cutting of adjustable skylights made of plexiglass
D. Seal with an adjustable cover plate for skylight
Answer: D
18. The capacity management module of the NetEco management system can manage the resource
capacity information in the computer room.
Which of the following capacity factors falls within the management scope of NetEco?
A. Network port
B. Network bandwidth
C. CPU utilization
D. None of the above
Answer: D
19.Which of the typical configurations of FusionModule800 are optional?
A. Temperature and humidity, door magnet, water immersion, smoke sensor, mobile phone APP
B. Smoke sensor, door sensor, water flooding, SMS alarm, pad
C. Water immersion, door sensor, video, backup power, ibattery
Answer: B
20. The NetEco management system can provide a temperature cloud map function to monitor the
temperature distribution in the computer room and quickly identify hot spots in the computer room.
A. True
B. False
Answer: A
21. The backup time of UPS system is generally within 30 minutes, so it is more reasonable to use
constant current method to calculate battery capacity.
A. True
B. False
4two​
NUMPAGES
Download valid H19-105_V2.0-ENU exam dumps for best preparation
Answer: B
22. Configure a modular redundant UPS system. As long as the number of modules meets the basic
requirements, there is no need to consider the distribution of UPS modules on different racks.
A. True
B. False
Answer: B
23. The air conditioning water system includes the cooling water system, the chilled water system and the
condensing water system.
A. True
B. False
Answer: A
24. Huawei precision air conditioners have RS485 communication interfaces for remote inspection and
parameter setting of the system: Modbus open protocol is provided to access the computer room
environment monitoring system to reduce service costs.
A. True
B. False
Answer: A
25. In UPS5000-A system, which of the following battery configuration is unreasonable?
A. 32 12V batteries
B. 37 12V batteries
C. 40 12V batteries
D. 42 12V batteries
Answer: B
26.FusionModule1000A V2R3 version IT solution comes standard with cabinet spring damping device
A. True
B. False
Answer: A
27.The power module efficiency of UPS5000-E (25-75kVA) is 96%.
A. True
B. False
Answer: A