H19-402_V1.0 HCSP-Presales-Data Center Network Planning and Design V1.0 Exam Preparation

advertisement
H19-402_V1.0
HCSP-Presales-Data Center Network Planning and
Design Exam Preparation
Target Audience
 pre-sales professionals of partners who sell
Huawei enterprise Data Center Network
products and Data Center Network
solutions
 who want to obtain the HCSP-Presales-Data
Center Network Planning and Design V1.0
certification
H19-402_V1.0 Exam Overview
Exam Type: Written examination
Exam Format: Single-answer Question, Multiple-answer
Question, True or false
Time: 90min
Passing Score/Total Score: 600/1000
Exam Cost: 100USD
Languages: Chinese, English
H19-402_V1.0 Exam Outline
1.Data Center Network Overview 16%
2.Technical Fundamentals of Data Communications Networks 9%
3.VXLAN and BGP EVPN 10%
4.M-LAG 9%
5.Intelligent Lossless Data Center Network 8%
6.Huawei CloudFabric Solution 17%
7.Four CloudFabric Service Automation Scenarios and Related
Solutions 4%
8.iMaster NCE-Fabric 6%
9.CloudFabric Underlay and Overlay Network Design 7%
10.Typical DCN Design Guide 11%
11.Intelligent O&M of the CloudFabric Solution 3%
H19-402_V1.0 Question
1. What line-in methods does UPS5000-A400/500K support?
A. Downstream line
B. Upper line
C. Up and down wiring compatible
H19-402_V1.0 Answer
C. Up and down wiring compatible
H19-402_V1.0 Question
2. What is the humidifier used by the row-level
chilled water intelligent temperature control
product NetCol5000-C032H?
A. Electrode
B. Infrared
C. Wet film
D. Ultrasound
H19-402_V1.0 Answer
C. Wet film
H19-402_V1.0 Question
3. UPS5000-E only needs to be equipped with ()
to easily realize the 2N power supply system,
which is simple and convenient to operate?
A. BSC cable
B. Synchronous Controller
C. BSC control panel
D. Parallel card
H19-402_V1.0 Answer
A. BSC cable
H19-402_V1.0 Question
4. Which of the following descriptions of the eLight
function of the intelligent module status indicator in
FusionModule2000v3.0 is correct?
A. The door frame indicator light eLight is only a
decorative atmosphere rendering function
B. Door frame indicator lights can be associated with
alarm status
C. Door frame indicator light eLight is a module lighting
function
D. None of the above is correct
H19-402_V1.0 Answer
B. Door frame indicator lights can
be associated with alarm status
H19-402_V1.0 Question
5. UPS5000-A/E 400KVA and above models are divided
into standard version and enhanced version. The
standard version is equipped with () isolation switch.
A. Main input
B. Bypass Input
C. Repair
D. Output
H19-402_V1.0 Answer
C. Repair