Uploaded by Teo Puskar

Quiz [SVC L2] Attempt review

advertisement
Quiz [SVC L2]: Attempt review
1 of 11
https://learn.ibm.com/mod/quiz/review.php?attempt=3354019&cmid=...
Quiz [SVC L2]
Back
You must receive a score of 75% or higher on the quiz to complete
Next
the course.
Started on
State
Completed on
Monday, August 19, 2024, 5:45 AM
Finished
Monday, August 19, 2024, 6:03 AM
Time taken
18 mins 8 secs
Feedback
Congratulations, you have passed the
quiz!
Question 1
Correct
Points out of 1.00
What unique ability does Easy Tier provide when it is used with
a group of storage arrays that are being virtualized with SAN
Volume Controller (SVC)?
It enables intra-hard disk drive (HDD) data migration on the
same drive
It supports tiering between virtualized arrays 
It enables tiering between the main SVC node and a hot
spare node
It enables tiering between virtualized and non-virtualized
arrays
19/08/2024, 12:04
Quiz [SVC L2]: Attempt review
2 of 11
https://learn.ibm.com/mod/quiz/review.php?attempt=3354019&cmid=...
Question 2
Correct
Points out of 1.00
Back
Next
The Easy Tier functionality in Storage Virtualize is impressive. It
employs AI to automatically optimize performance by moving
frequently accessed data to the fastest storage tier. Why is Easy
Tier even more impressive when it is used with SAN Volume
Controller?
It can move Safeguarded Copy snapshots to a faster tier
It can tier between virtualized arrays to enhance all
systems

It uses policy-based rules when employed in a virtualized
environment
It is 27% faster than when used with a single storage array
Question 3
Correct
Points out of 1.00
How can the reliability of a SAN Volume Controller (SVC) cluster
be further enhanced?
By ordering the “enhanced reliability cluster” (ERC)
feature.
With the use of hot spare node(s). 
By implementing an Enhanced Stretched Cluster.
By adding a third, or fourth, boot drive.
19/08/2024, 12:04
Quiz [SVC L2]: Attempt review
3 of 11
https://learn.ibm.com/mod/quiz/review.php?attempt=3354019&cmid=...
Question 4
Correct
Points out of 1.00
Back
Next
A seller is talking to a client who already has some slightly older
SAN Volume Controller (SVC) nodes and they are thinking about
adding a couple more. They are concerned about having
different models. What could the seller tell them to help ease
their concerns?
As long as the cluster code meets or exceeds the

minimum code requirement for the new nodes, there is
no problem running various node generations in
different I/O groups of a cluster.
As long as the I/O group code meets or exceeds the
minimum code requirement for the new nodes, there is no
problem running various node generations in the I/O group
There is no problem running various node generations in
the same I/O Group and they will automatically join the
group regardless of the version of the OS.
There is no problem running various node generations in
the same cluster and they will automatically join the group
regardless of the version of the OS.
Question 5
Incorrect
Points out of 1.00
What High Availability (HA) environment can automatically
mirror Safeguarded Copies when working with a SAN Volume
Controller environment?
Enhanced Stretched Cluster
Policy-based High Availability (PBHA) 
Policy-based Replication (PBR)
HyperSwap
19/08/2024, 12:04
Quiz [SVC L2]: Attempt review
4 of 11
https://learn.ibm.com/mod/quiz/review.php?attempt=3354019&cmid=...
Question 6
Incorrect
Points out of 1.00
Back
Next
A seller is speaking with an IT Director at a university who has
been told their department must establish an HA con�guration
between two buildings on campus. The Director explains they
have numerous storage arrays from different vendors and none
of them can easily communicate with each other. The Director
also explains they do not have the budget to acquire new
storage systems to solve the problem. What unique use case
could the seller suggest that would inexpensively, and uniquely,
solve the university’s problem?
SAN Volume Controller using Safeguarded Copy
SAN Volume Controller Stretched Cluster
SAN Volume Controller using HyperSwap
SAN Volume Controller using PBHA 
Question 7
Incorrect
Points out of 1.00
A client has two SVC SA2 nodes at a primary site where they
have several third-party storage arrays. They also have two SVC
SA2 nodes at a second site, which is 80km away, which also has
several storage arrays. The client wishes to create an HA
con�guration between the two sites. As of June of 2024, what is
the recommended solution for a performance optimized HA
con�guration between two sites?
Policy-based High Availability (PBHA)
Stretched Cluster
Policy-based Replication (PBR)
HyperSwap 
19/08/2024, 12:04
Quiz [SVC L2]: Attempt review
5 of 11
https://learn.ibm.com/mod/quiz/review.php?attempt=3354019&cmid=...
Question 8
Correct
Points out of 1.00
Back
Next
IBM has made it simple for clients to take an already robust,
solid solution like SVC and obtain enhanced reliability with it.
What ability/feature has IBM created to make restoring
redundancy easy in the event of a failed node?
Redundant Node Multiplier
HyperSwap
HA Failover Link
Hot Spare Node 
Question 9
Correct
Points out of 1.00
A client seems genuinely interested in understanding the base
software that provides rich functionality in all SAN Volume
Controller models. What is the name of that software?
IBM Storage Virtualize 
IBM Storage Accelerate
IBM Storage Control
IBM Storage Discover
19/08/2024, 12:04
Quiz [SVC L2]: Attempt review
6 of 11
https://learn.ibm.com/mod/quiz/review.php?attempt=3354019&cmid=...
Question 10
Correct
Points out of 1.00
Back
Next
During a client meeting, a seller is asked, what is the maximum
distance a Stretched Cluster can be spread across. What is the
best response?
300km, and it is strongly promoted as a great distance
200km
300km, but it is not encouraged due to latency issues 
10km
Question 11
Correct
Points out of 1.00
What two models of SAN Volume Controllers are being sold as
of June of 2024?
SA2 and SV3 
SV1 and SV3
SV2 and SV3
SA2 and SV2
19/08/2024, 12:04
Quiz [SVC L2]: Attempt review
7 of 11
https://learn.ibm.com/mod/quiz/review.php?attempt=3354019&cmid=...
Question 12
Correct
Points out of 1.00
Back
Next
During a discussion about Ransomware Threat Detection, a
client is clearly interested in the automated alerting mechanism
that the seller is describing. What speci�c software is required
for the alerting?
IBM Storage Insights pro 
IBM Storage Insights
IBM Storage Assurance
IBM Storage Defender
Question 13
Correct
Points out of 1.00
A client is expressing concern over basing their storage
infrastructure on a new cutting edge virtualization technology.
What SAN Volume Controller (SVC) celebration should a seller
point out to the client?
SVC had its 18th Anniversary in 2023
SVC had its 20th Anniversary in 2023 
SVC had its 16th Anniversary in 2023
SVC had its 15th Anniversary in 2023
19/08/2024, 12:04
Quiz [SVC L2]: Attempt review
8 of 11
https://learn.ibm.com/mod/quiz/review.php?attempt=3354019&cmid=...
Question 14
Correct
Points out of 1.00
Back
Next
A client asks a seller, “What represents the key value
propositions for SAN Volume Controller?” What response is
correct?
Simpli�ed data migrations, lower storage utilization, and
higher total cost of ownership
SVC provides common management, advanced
functions, improved storage utilization, and simpli�ed
data migrations.

Underlying storage keeps its own sets of enhanced
functions managed separately, and simpli�ed data
migrations.
Improved storage utilization, simpli�ed data migrations,
and increased response times
Question 15
Correct
Points out of 1.00
Sellers should discuss cyber and data security when talking
about SAN Volume Controller. What powerful immutability
snapshot feature is built in to SVC which makes it available to
third-party storage?
Safeguarded Copy 
Storage Class Memory (SCM)
Data Protect
IBM Storage Defender
19/08/2024, 12:04
Quiz [SVC L2]: Attempt review
9 of 11
https://learn.ibm.com/mod/quiz/review.php?attempt=3354019&cmid=...
Question 16
Correct
Points out of 1.00
Back
Next
As of mid-2023, with Storage Virtualize 8.6.0, or greater, what
new cyber resiliency feature is available for all members of the
IBM FlashSystem and SAN Volume Controller families?
There are no new universally available cyber resiliency
features for the SAN Volume Controller family
QRadar
Safeguarded Copy
Ransomware Threat Detection 
Question 17
Correct
Points out of 1.00
How does Policy-based High Availability (PBHA) simplify the
con�guration, management and monitoring of HA with SVC and
FlashSystem?
Through the use of Storage partitions, AI and volume
groups.
Through the use of AI and volume groups.
Through the use of Storage partitions, policies and
volume groups.

Through the use of policies and volume groups.
19/08/2024, 12:04
Quiz [SVC L2]: Attempt review
10 of 11
https://learn.ibm.com/mod/quiz/review.php?attempt=3354019&cmid=...
Question 18
Correct
Points out of 1.00
Back
Next
A client has asked the seller to explain what items are part of a
storage partition. What should the seller say?
Storage Partitions consist of Data Reduction Pools,
FlashCopy mappings and a cloud account.
Storage Partitions consist of IP partnership, certi�cates and
activated encryption.
Storage Partitions consist of host objects, volume-tohost mappings, and volume groups.

Storage Partitions consist of host objects, host clusters and
mdisks.
Question 19
Correct
Points out of 1.00
Once external storage systems have been virtualized, how does
SAN Volume Controller provide data reduction for those storage
systems?
Add in hardware compression cards
Inline hardware compression through FlashCore Modules
Wavelet-based ECG compression
Data Reduction Pools (DRP) 
19/08/2024, 12:04
Quiz [SVC L2]: Attempt review
11 of 11
https://learn.ibm.com/mod/quiz/review.php?attempt=3354019&cmid=...
Question 20
Correct
Points out of 1.00
Back
Next
A seller assures a client that SAN Volume Controller (SVC)
provides a wide range of features/abilities. The seller points out
that IBM has con�gured SVCs to support suf�cient memory to
handle all the various features/abilities. What is the maximum
amount of cache that is supported in a SAN Volume Controller
SA2 node?
768GB 
384GB
128GB
512GB
19/08/2024, 12:04
Download