An atomic absorption spectrometer(AAS), also known as atomic absorption spectrophotometer, analyzes metal elements
according to the effect of ground state atomic vapor on characteristic radiation absorption. It can determine trace or trace
elements sensitively and reliably.
Optional Accoessories:
Graphite Furnace
Air Compressor
Printer
Burner Head
Software ( No computer )
Glass atomizer
Hydride Generator
Chilled water unit
Ventilating Hood ( 1.5 meters )
Get Free Quote
DW-AA320N Manual
DW-AA320N Brochure
Description
Features of DW-AA320N Atomic Absorption Spectrophotometer
1. Build-in computer data processing and LCD display: stable and reliable with the functions of integral holding, peak
height and area, auto zero adjusting, deuterium lamp background correction, multi-linear and nonlinear curves
fitting, various parameters, and working curves displayed in the screen and report printing, etc. It is equipped with
an interface for externally linking PC.
2. Stability: Double-beam system can automatically compensate for the light source drift and wavelength drift caused
by the variation of temperature (with the function of eliminating the affection of wavelength drift on the baseline
stability) and electronic circuit drift so as to reach good basic line stability.
3. Quickly: The cathode lamp needs not to be pre-heated for a long time and the sample can be analyzed immediately.
It is the preferred instrument chosen by users to conduct analysis of multiple kinds of elements and fast analysis of
samples.
4. High precision of measurement: The gas path system is equipped with precision pressure stabilizing and current
stabilizing devices to reach stable flame and low noise. A specially designed fine light beam passes through the
https://www.drawellanalytical.com/double-beam-dw-aa320nr-atomic-absorption-spectrophotometer-1-lamp-stand/
2/11
2024/8/13 23:08
Double Beam DW-AA320N Atomic Absorption Spectrophotometer - Drawell
flame to ensure a high precision analytical test and low characteristic concentration
5. High energy optical path: A total reflection system is adopted to eliminate the color differences in the full range. By
means of chemical conversion, a round light spot of the light source becomes a long light spot, which enters into the
slit. Therefore the light flux of the double beam is enhanced.
6. Long-life and anti-corrosive atomization system: The burner is made of a new type of titanium alloys, anti-corrosive
and fast thermal equilibrium. It meets the requirement of measurement sensitivity without water-cooling.
7. Multi-functional analysis mode: for methods of flame absorption, flame emission, graphite furnace atomic
absorption, and hydride generation.
8. Safe and reliable gas path system: Special devices of quick gas conversion and safety protection can be used to
analyze air-acetylene flame as well as nitrous oxide-acetylene flame and extend the analytic elements to reach
more than 60.
9. Complete set of accessories: to be supplied with the instrument and ready for use after they are purchased.
DW-AA320N Installation and Operation video
https://www.drawellanalytical.com/double-beam-dw-aa320nr-atomic-absorption-spectrophotometer-1-lamp-stand/
3/11
2024/8/13 23:08
Double Beam DW-AA320N Atomic Absorption Spectrophotometer - Drawell
Double Beam Atomic Absorption Spectrophotometer
Specifications of the PDW-AA320N Spectrophotometer:
https://www.drawellanalytical.com/double-beam-dw-aa320nr-atomic-absorption-spectrophotometer-1-lamp-stand/
4/11
2024/8/13 23:08
Double Beam DW-AA320N Atomic Absorption Spectrophotometer - Drawell
WL range (nm)
190-900
WL accuracy
0.5nm
WL repeatability
0.3nm (single direction)
Spectrum bandwidth
0.2nm, 0.4nm, 0.7nm, 1.4nm, 2.4nm, 5.0nm
Resolution
<40%
Base line stability
0.004Abs/30min
Characteristic concentration of copper
0.04g/ml/l%
Detection limit of copper
0.008g/ml
Background calibration ability
Greater than 30 times
RS232
including
Printer
optional
Power supply
220V 3A, 50Hz
G.W.
160Kg (Main instrument),
65Kg ( Accessories )
1220x770x730mm (Main instrument) ,
800x400x900mm ( Accessories ) Titanium b
— 5cm
Package Dimensions
Nitrous oxide generator
Hydride generator
Graphite tubes
Acetylene Regulator YQE-213
Optional Accessories
Nitrous oxide regulator
Software
recirculating cooling water system
DW-AA320N Packing List
https://www.drawellanalytical.com/double-beam-dw-aa320nr-atomic-absorption-spectrophotometer-1-lamp-stand/
5/11
2024/8/13 23:08
Double Beam DW-AA320N Atomic Absorption Spectrophotometer - Drawell
Item.
Descriptions
Qty.
1
Main instrument
1
2
Power cable
1
3
Operating manual
1
4
Burner unit
1
5
Water-separating gas filter base
1
6
Bush
10
7
Threaded sleeve
10
8
Dust cover
1
9
Gasket
15
10
Sheet gasket
4
11
Scale plate for adjust the light
1
12
Joint
1
13
Pul-out piece spring
1
14
Input Joint
1
15
Output Joint
1
16
Closure head
2
17
Hand knob
1
18
Scale disk
1
19
Acetylene Regulator YQE-213
1
20
Water-separating gas filter QSL1/4’
1
21
PU plastic tube Φ 6*1
15M
22
PVC tube Φ10*1.4
3M
23
O gland ring D10*2
10
24
O gland ring D16*2
4
25
O gland ring D32*3
6
26
O gland ring D40*3
6
27
Fuse 2A
5
28
Fuse 0.5A
5
29
Fuse 0.1A
5
30
Nut runner
4
31
Tools
1
32
Glass Atomizer
1
33
Hollow cathode lamp Cu
1
https://www.drawellanalytical.com/double-beam-dw-aa320nr-atomic-absorption-spectrophotometer-1-lamp-stand/
6/11
2024/8/13 23:08
34
Double Beam DW-AA320N Atomic Absorption Spectrophotometer - Drawell
Oil-free diaphragm air compressor
1
DW-AA320N Spectrophotometer Display
Customer Feedback of DW-AA320N Spectrophotometer
https://www.drawellanalytical.com/double-beam-dw-aa320nr-atomic-absorption-spectrophotometer-1-lamp-stand/
7/11
2024/8/13 23:08
Double Beam DW-AA320N Atomic Absorption Spectrophotometer - Drawell
https://www.drawellanalytical.com/double-beam-dw-aa320nr-atomic-absorption-spectrophotometer-1-lamp-stand/
8/11
2024/8/13 23:08
Double Beam DW-AA320N Atomic Absorption Spectrophotometer - Drawell
Other Spectrophotometer
https://www.drawellanalytical.com/double-beam-dw-aa320nr-atomic-absorption-spectrophotometer-1-lamp-stand/
9/11
2024/8/13 23:08
Double Beam DW-AA320N Atomic Absorption Spectrophotometer - Drawell
Energy Dispersion X-ray Fluorescence Spectrometer (DW-NP-
TrueX 800 Alloy Analyzer
5010)
K5800/K5800C Nano Spectrophotometer (with cuvette)
Handheld XRF Gold Analyzer (TrueX G5/ TrueX G7)
FAQ
Q1. Are you a factory or trading company?
Q2. What’s the MOQ?
Q3. What is your principle for the samples?
Q4.Which payment can be acceptable?
https://www.drawellanalytical.com/double-beam-dw-aa320nr-atomic-absorption-spectrophotometer-1-lamp-stand/
10/11
2024/8/13 23:08
Double Beam DW-AA320N Atomic Absorption Spectrophotometer - Drawell
Q5. How about your delivery time?
Q6. Certificate & Quality
Q7. Language
Q8. Service
Q9.Training
Q10. If you have other questions, you can contact us through:
CONTACT US
weIcome to contact us, we wiIl do our best to help you !
Name*
Company
Email*
5123 4567
Message*
Captcha *
3*4=
Submit
0086-023-63268643
0086 13320353102
sales08@drawell.com.cn
Suite 2705,Building No.12,(Evergrande City Square) Shiyou
Road No.1, Yuzhong District, Chongqing, China.
DRAWELL is specialized in R&D laboratory instruments :
ABOUT US
Spectrophotometer, Refractometer , Melting Point Meter ,
https://www.drawellanalytical.com/double-beam-dw-aa320nr-atomic-absorption-spectrophotometer-1-lamp-stand/
11/11
Download