TECHNICAL SPECIFICATIONS – AIR HANDLING UNIT (AHU) An air handling unit (AHU) is a device used to generate a large volume of air to recondition and circulate as a part of cooling, heating and ventilating systems in buildings. These AHU’s are connected through duct work that distributes the conditioned supply air to the various rooms in building and returns it to the AHU. The design of AHU is according to “Class 100 as per FS 209E”. PRODUCT : AIR HANDLING UNIT (AHU) MATERIAL OF CONSTRUCTION : OUTER SKIN Pre Coated GI SS 304 INNER SKIN GI (Normal) SS 304 DESIGN MODEL : Base Mounted Ceiling Suspended ACCESSORIES AND OTHER FEATURES STRUCTURAL CONSTRUCTION : Thermal or Non Thermal Aluminum extruded profile construction sealed with leak proof gasket strips between panel and Profiles. PANELS : Double Skin PU puff insulated panel, with light weight, good rigidity and thermal conductivity, Puff density 40 kg/m3 Panel Thickness 25 mm ; 43 mm step panel HARDWARE : Nylon AHU Door Handles, Door Knobs, Door Hinges, Nylon corner blocks, and all necessary fasteners, etc… AIR FILTERATION : Stage-1: Fresh air filter (EU-7) 10 micron Stage-2: Pre filter (EU-5) 5 micron Stage-3:Fine Filter (EU-4) 3 Micron COOLING/HEATING : Cooling / Heating coil (Dual sine wave fins are mechanically bonded with copper tubes,releasing excelent cooling/heating transfer effeciency. The coil header is constructed with steel or copper. SS drain tray is arranged to drain out the water in the coil in winter to avoid the frost crack of the coil. DX Coil ; Chilled Water coil ; Other (Coil capacity will calcualted on CFM Required) BLOWER : The blower unit is designed with Backward or forward centrifugal type with low noise and hign efficiency,the impeller and pully are statically and dynamically balanced.The blower and motor assembly mounted on common base with shock obsorber to operate the fan stably and smoothly. Kruger ; Rosenberg ; Equivalent made DAMPER : To control the volume of air with no leakage, The VCD are made up of Galvanized steel Fresh air damper, Supply air, Return air VCD Dampers TECHNICAL SPECIFICATIONS – AIR HANDLING UNIT (AHU) OTHER OPTIONAL EXTER FEATURES : 3rd Stage of Filtration with HEPA (EU-13/H-14) 0.3 micron View glass shall fitted to all fan and coil section View glass shall fitted to all access panels Accessible area in unit shall fitted with bulk head lights Non-Standard colors of unit available Electrical control panel to operate the unit. UV light in Coil section Heater bank in supply air filter section Fusible or motorized fire damper at supply duct along with VCD. CLEANLINESS : ISO-5 (AS PER ISO-14644-1); CLASS 100 (AS PER FS209E) VALIDATION PROCEDURE : AIR VELOCITY TEST, LEAK (PAO) TEST; PARTICLE COUNT TEST. CERTIFICATION : FILTER TEST CERTIFICATES, MOC TEST REPORTS APPLICATIONS Pharmaceutical Industries Chemical Research laboratories Hotel buildings Shopping malls LINE DIAGRAM OF AIR HANDLING UNIT