MECHANICAL TEST CERTIFICATE
DELHI TEST HOUSE
A-62/3, G.T.KARNAL ROAD, INDL.AREA,(Opp.HANS CINEMA),AZADPUR, NEW DELHI-110 033
Date : 12/05/2022
Customer Name : NABL
Test Type :
File Name
Sample Type
: Tensile Test - Stress Vs Strain
: 5220506.GEN.147
: Strand
D1 : 5.02 , D2 : 5.06 ,
D3 : 5.05 , D4 : 5.09 ,
D5 : 5.01 , D6 : 5.08 ,
Straightness (mm)
D7 - core : 5.22 ,
: 600.0
: 227.0
: 15.2
: 0.05
Initial Area (mm2)
: 141.64
Gauge Length (mm)
Lay Length (mm)
Nominal Dia (mm)
Sample Id :
Material Test Results
Max. Load (kN)
Tensile Strength (N/mm2)
Disp. at Max. Load (mm)
Max. Displacement (mm)
Proof Load 0.2 % Offset (kN)
Youngs Modulus (N/mm2)
Difference
Difference %
Elongation %
Final Gauge Length (mm)
: TMT 25 MM FE 500
: 260.843
261.52
: 1841.589
1846.37
: 55.85
: 62.65
: 233.785
: -41076.584
189214.451
: 0.13
: 2.554
: 5.833
: 635.0
STRAND WIRE 15.2MM
:
Tested By
Make :
Witnessed By
Machine Sr.No : 12/2001-2807
Authorized By
Model - UTE-100-CES