SD SD SD SD FE FE SD SD SD SD SD FE FE FACP MCP SD SD SD SD MCP SD FE JUNEL T. PON PROPOSED LAYOUT PLAN FOR FIRE DETECTION AND ALARM SYSTEM LOBOC, BOHOL FDAS LAYOUT WIRING DIAGRAM E 1 SD SD SD SD SD SD SD FE SD SD SD FE MCP SD SD MCP FE FE JUNEL T. PON SD PROPOSED LAYOUT PLAN FOR FIRE DETECTION AND ALARM SYSTEM LOBOC, BOHOL FDAS LAYOUT WIRING DIAGRAM E 2 SD SD FE FE SD MCP SD MCP SD FE JUNEL T. PON SD FE PROPOSED LAYOUT PLAN FOR FIRE DETECTION AND ALARM SYSTEM LOBOC, BOHOL FDAS LAYOUT WIRING DIAGRAM E 3 SD FE SD SD SD SD FE MCP SD SD SD MCP FE JUNEL T. PON FE PROPOSED LAYOUT PLAN FOR FIRE DETECTION AND ALARM SYSTEM LOBOC, BOHOL FDAS LAYOUT WIRING DIAGRAM E 4 LEGEND: GENERAL ELECTRICAL NOTES: 1. EXACT QUANTITIES OF EXISTING DEVICES ARE NOT SHOWN. 2. ALL NEW DEVICES SHALL BE PURCHASED FROM THE BUILDING FIRE ALARM MAINTENANCE CONTRACTOR TO ENSURE COMPATIBILITY WITH BUILDING'S FIRE ALARM SYSTEM. 3. REPROGRAMMING OF THE BUILDING FIRE ALARM CONTROL PANEL SHALL BE DONE BY THE BUILDINGS FIRE ALARM MAINTENANCE CONTRACTOR. 4. EXISTING BUILDING SYSTEMS ARE NOT SHOWN AND SHALL REMAIN ACTIVE. 5. OBTAIN PERMISSION FROM THE BUILDING MANAGER PRIOR TO STARTING OF WORK. 6. PRIOR TO STARTING OF THE FIRE ALARM WORK, THE CONTRACTOR SHALL CONTACT THE BUILDING FIRE ALARM VENDOR AND THE BUILDING CHIEF ENGINEER FOR DIRECTIONS. 7. ALL WIRING SHALL BE PER MANUFACTURER'S REQUIREMENT AND RECOMMENDATION AND MEET APPLICABLE CODE REQUIREMENTS.. 8. PROJECT SPECIFIC FIRE ALARM RISER DIAGRAM AND SHOP DRAWINGS, INCLUDING BATTERY CALCULATIONS AND NOTIFICATION APPLIANCE CIRCUIT VOLTAGE DROP ANALYSIS PLUS SEQUENCE OF OPERATIONS, SHALL BE PREPARED AND SUBMITTED, BY THE FIRE ALARM VENDOR, TO THE PROJECT ENGINEER FOR APPROVAL. ROOM NAMES AND NUMBERS ON PLANS ARE NOT FOR LABELING OR PROGRAMMING USE. CONSULT WITH OWNER FOR THIS INFORMATION. AFTER APPROVAL BY THE ENGINEER, A SUBMITTAL, SIGNED BY A REGISTERED NICET LEVEL 4, AND ASSOCIATED WITH THE FIRE ALARM VENDOR, SHALL BE FORWARDED TO THE PROJECT ENGINEER FOR SUBMITTAL TO THE AUTHORITIES HAVING JURISDICTION 9. ALL FIRE ALARM WIRING SHALL BE TYPE FPLP IN RACEWAY AND SHALL BE CONCEALED IN WALLS AND CEILINGS SPACES. 10. PLENUM RATED CABLE WITHOUT RACEWAY IS ACCEPTABLE ONLY IN CONCEALED CEILING SPACES. GALVANIZED EMT (3/4" MIN) SHALL BE USED FOR ALL RUNS BELOW CEILING. METAL WIREMOLD MAY BE USED ON CEILINGS WHERE NO ACCESS IS AVAILABLE TO CONCEAL CABLE-RUN. ALL CONDUITS OR WIREMOLD, WHEN EXPOSED, SHALL BE PAINTED TO MATCH ADJACENT AREA. 11. ALTERNATE IN ATTIC SPACES. (EXTREME HEAT CONDITIONS) CONTACT PROJECT ENGINEER FOR RESOLUTION. 12. BE FAMILIAR WITH STRUCTURE PRIOR TO START OF WORK IN ORDER TO PROVIDE A FIRE ALARM SYSTEM THAT COMPLIES WITH ALL APPLICABLE CODES, OWNER'S UNDERWRITER REQUIREMENTS, AND RECOMMENDATIONS OF LOCAL AUTHORITIES HAVING JURISDICTION. IF CONTRACTOR FAILS TO COMPLY, NO ADDITIONAL COMPENSATION WILL BE AWARDED FOR WORK THAT IS REASONABLE HAD A PRE-CONSTRUCTION FIELD SURVEY BEEN COMPLETED. 13. A 100% TOTAL ACCEPTANCE TEST SHALL BE PERFORMED AT THE COMPLETION OF THE NEW FIRE ALARM SYSTEM INSTALLATION PER INTERNATIONAL BUILDING CODE (IBC) SEE SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS 14. ALARM VENDOR SHALL PROVIDE WIRE GUARDS/COVERS ON ALL PULL-STATIONS, HORN-STROBES, AND DETECTORS LOCATED IN PUBLIC AREAS SUCH AS, GYMNASIUMS, LOCKER-ROOMS, ETC. (TYPICAL) LOW PROFILE DETECTORS SHALL BE USED IN ALL HALLWAYS. 15. FIRE ALARM SPECIFICATIONS SHALL BE USED IN CONJUNCTION WITH ALL DRAWINGS. ANY DISCREPANCIES SHALL BE BROUGHT TO TO ATTENTION OF THE ENGINEER FOR RESOLUTION. 16. HEAT DETECTORS IN THE ELEVATOR MACHINE ROOMS AND ELEVATOR SHAFTS SHALL BE PROGRAMMED TO SIGNAL CONTROL MODULES FOR ELEVATOR SHUT DOWN VIE A SHUNT TRIP ON THE ELEVATOR FEEDER PER ASME A17.1 17. PROVIDE DUCT SMOKE DETECTORS IN RETURN DUCTS OF ALL HVAC SYSTEMS OVER 2000 CFM, OR AS REQUIRED BY INTERNATIONAL MECHANICAL CODE (IMC). DETECTORS, HOUSINGS, AND SAMPLING TUBES SHALL BE PROVIDED AND WIRED BY THE ELECTRICAL CONTRACTOR AND INSTALLED IN THE DUCTWORK BY THE MECHANICAL CONTRACTOR, UNO. 18. PROVIDE A DEDICATED CONTROL MODULE FOR EACH DETECTOR TO BE PROGRAMMED TO SEND A SHUTDOWN SIGNAL TO THE HVAC SYSTEM TO SHUTDOWN THE FAN, MOTORS, DAMPERS, ETC. ALL LOW VOLTAGE WIRING BETWEEN THE CONTROL MODULE AND THE HVAC SYSTEM SHALL BE BY THE ATC CONTRACTOR, UNO. 19. CONTRACTOR SHALL INSTALL ALL ABOVE CEILING DEVICES AFTER ALL PIPING, DUCTWORK, CONDUITS, ETC ARE INSTALLED SUCH THAT THE FIRE ALARM DEVICE IS EASILY ACCESSIBLE. COORDINATE LOCATIONS WITH THE STRUCTURE AND ALL OTHER UTILITIES. 20. PROVIDE A SMALL SCALE FLOORPLAN INCLUDING ROOM NAMES/NUMBERS, MOUNTED BEHIND A PLEXIGLASS FRAME, ADJACENT TO THE REMOTE ANNUNCIATOR PANEL. JUNEL T. PON AUTOMATIC FIRE DETECTOR/ CARBON MONOXIDE DETECTOR ZONE 7 END OF THE LINE - + MCP - + FIRE ALARM - SD EMERGENCY LIGHT + continue based on the layout SD FIRE EXTINGUISHER SIXTH FLOOR EVACUATION AREA ZONE 6 END OF THE LINE - + MCP - + - SD + continue based on the layout SD MAIN PANEL BOARD FIFTH FLOOR ZONE 5 END OF THE LINE - + MCP - + ESCAPE ROUTE - + SD SD FACP continue based on the layout FOURTH FLOOR MCP ADDRESABLE FIRE ALARM CONTROL PANEL MANUAL CALL POINT ZONE 4 END OF THE LINE - + MCP - + - + continue based on the layout SD SD THIRD FLOOR ZONE 3 END OF THE LINE - + MCP - + - SD + continue based on the layout SD SECOND FLOOR ZONE 2 END OF THE LINE - + MCP - + - + SD SD continue based on the layout FIRST FLOOR ZONE 1 END OF THE LINE - + MCP SD + - + SD continue based on the layout BASEMENT POWER 220V SOURCE FIRE ALARM/ BELL FACP DC 24V - + - + DC 12V DC 12V BACKUP BATTERY SUPPLY RISER DIAGRAM PROPOSED LAYOUT PLAN FOR FIRE DETECTION AND ALARM SYSTEM LOBOC, BOHOL GENERAL NOTES RISER DIAGRAM LEGEND E 5