DIESEL GENERATOR SET
MTU 1200 DS
1200kWe/60 Hz/Standby
380 VAC
SYSTEM RATINGS
Standby
Voltage (L-L)
Phase
PF
Hz
kW
kVA
Amps
Generator Model*
Temp Rise
Connection
380V
3
0.8
60
1200
1500
2280
743RSL4052
130°C/40°C
4 BAR WYE
* Consult Detroit Diesel MTU Peru for additional configurations.
STANDARDS
// Emissions – EPA Tier2 Certified
// Generator set is assembled and manufactured
in facilities certified to standards ISO 9001:2008 and
ISO 14001:2004.
Testing of Genset is according to ISO 8528-5 in order to
verify response, quality and performance in an automatic load
bank.
//
Consult Detroit Diesel MTU Peru for additional configurations.
// Power Rating (Load factor 85%)
- Permissible average power output during 24 hours of
operation is approved up to 85%.
/ // / MTU 1200DS (1200 kWe) 2
Standby
STANDARD FEATURES*
// 1 Year Standard Warranty
// Generator
// 16V 2000 Diesel Engine
- Brushless, Rotating Field Generator
- PMG (Permanent Magnet Generator) supply to regulator
- 300% Short Circuit Capability
// Digital Control Panel(s) optional (DGC2020 or similar)
- Complete System Metering
- LCD Display
// Cooling System
- Integral Set-Mounted
- Engine Driven Fan
- 31.8 Liter Displacement
- Electronic Unit Pump Injection
- 4-Cycle
// Complete Range of Accessories
STANDARD EQUIPMENT*
// Engine
Air Cleaners
Oil Pump
Oil Drain Extension & S/O Valve
Full Flow Oil Filter
Closed Crankcase Ventilation
Jacket Water Pump
Inter Cooler Water Pump
Thermostats
Blower Fan & Fan Drive
Radiator - Unit Mounted
Electric Starting Motor - 24V
Governor – Electronic Isochronous
Base - Structural Steel
SAE Flywheel & Bell Housing
Charging Alternator - 24V
Battery Box & Cables
Flexible Fuel Connectors
Flexible Exhaust Connection
EPA Certified Engine
// Generator
NEMA MG1, IEEE and ANSI standards compliance for
temperature rise and motor starting
Sustained short circuit current of up to 300% of the rated current
for up to 10 seconds
Self-Ventilated and Drip-Proof
Superior Voltage Waveform
Digital, Solid State, Volts-per-Hertz Regulator
Consult Detroit Diesel MTU Peru for additional configurations.
No Load to Full Load Regulation
Brushless Alternator with Brushless Pilot Exciter
4 Pole, Rotating Field
130 °C Maximum Standby Temperature Rise
1 Bearing, Sealed
Flexible Coupling
Full Amortisseur Windings
125% Rotor Balancing
3-Phase Voltage Sensing
±0.25% Voltage Regulation
100% of Rated Load - One Step
5% Maximum Total Harmonic Distortion
// Digital Control Panel(s)
Digital Metering
Engine Parameters
Generator Protection Functions
Engine Protection
CANBus ECU Communications
Windows®-Based Software
Multilingual Capability
Programmable Input and Output Contacts
UL Recognized, CSA Certified, CE approved
Event Recording
IP 54 Front Panel Rating with Integrated Gasket
/ // / MTU 1200DS (1200 kWe) 3
Standby
APPLICATION DATA
// Engine
// Fuel Consumption
Manufacturer
Model
Type
Arrangement
Displacement: L (in3)
Bore: cm(in)
Stroke: cm (in)
Compression Ratio
Rated RPM
Engine Governor
Maximum Power: kWm(bhp)
Speed Regulation
Air Cleaner
MTU
18V 2000 G85
4-Cycle
18-V
35.8 (2,186)
13 (5.1)
15 (5.9)
16:1
1,800
Electronic Isochronous (ADEC)
1,310 (1,755)
±0.25%
Dry
// Liquid Capacity (Lubrication)
Total Oil System: L (gal)
Engine Jacket Water Capacity: L (gal)
System Coolant Capacity: L (gal)
130 (34.3)
120 (31.7)
209 (56)
// Electrical
Electric Volts DC
Cold Cranking Amps Under -17.8 °C (0 °F)
24
2,800
At 100% of Power Rating: L/hr (gal/hr)
At 75% of Power Rating: L/hr (gal/hr)
At 50% of Power Rating: L/hr (gal/hr)
315(83)
245 (65)
165(44)
// Cooling - Radiator System
Ambient Capacity of Radiator: °C (°F)
Maximum Restriction of Cooling Air, Intake,
and Discharge Side of Rad.: kPa (in. H2 0)
Water Pump Capacity: L/min (gpm)
Heat Rejection to Coolant: kW (BTUM)
Heat Rejection to After Cooler: kW (BTUM)
Heat Radiated to Ambient: kW (BTUM)
Fan Power: kW (hp)
40 (104)
0.2 (0.8)
867 (229)
510 (29,003)
360 (20,473)
50 (2,841)
58 (77.8)
// Air Requirements
Aspirating: *m3/min (SCFM)
Air Flow Required for Rad.
Cooled Unit: *m3/min
Remote Cooled Applications;
Air Flow Required for Dissipation
of Radiated Gen-set Heat for a
Max of 25 °F Rise: *m3/min (SCFM)
108 (3,814)
1,716 (60,600)
N/A
* Air density = 1.184 kg/m3 (0.0739 lbm/ft3)
// Fuel System
Fuel Supply ConnectionSize
Fuel Return Connection Size
Maximum Fuel Lift: m (ft)
Recommended Fuel
Total Fuel Flow: L/ hr (gal/ hr)
Consult Detroit Diesel MTU Peru for additional configurations.
3/4”NPT
1/ 4” NPT
3 (10)
Diesel # 2
480 (146)
// Exhaust System
Gas Temp. (Stack): ° C (° F)
Gas Volume at Stack
Temp: m3/min (CFM)
Maximum Allowable
Back Pressure: kPa (in. H20)
530 (986)
264 (9.323)
9 (34)
/ // / MTU 1200DS (1200 kWe) 4
Standby
WEIGHTS AND DIMENSIONS
Drawing above for illustration purposes only, based on standard open power 480 volt generator set. Lengths may vary with other voltages. Do not use for installation design.
See website for unit specific drawings.
System
Open Power Unit (OPU)
Dimensions (L xWxH)
5.0 x 2.14 x 2.5 m
Weight (less tank)
9,135kg (20,139lb)
Weights and dimensions are based on open power units and are estimates only. Consult the factory for accurate weights and dimensions for your specific generator set.
SOUND DATA
Unit Type
Level 0: Open Power Unit dB(A)
Standby Full Load
C/F
Sound data is provided at 7 m (23 ft). Generator set tested in accordance with ISO 8528-10 and with infinite exhaust.
EMISSIONS DATA
NO + NMHC
5.11
CO
0.45
RATING DEFINITIONS AND CONDITIONS
PM
0.02
// Standby ratings apply to installations served by a reliable
utility source. The standby rating is applicable to varying
loads for the duration of a power outage. No overload
All units are in g/hp-hr and shown at 100% load
capability for this rating. Ratings are in accordance with
(not comparable to EPA weighted cycle values).
ISO 8528-1, ISO 3046-1, BS 5514, and AS 2789. Average
Emission levels of the engine may vary with ambient
load factor: ≤ 85%.
// Deration Factor:
temperature, barometric pressure, humidity, fuel type and
Altitude: Consult your local distributor
quality, installation parameters, measuring instrumentation, etc.
for altitude derations.
The data was obtained in compliance with US EPA regulations.
Temperature: Consult your local distributor
The weighted cycle value (not shown) from each engine is
guaranteed to be within the US EPA Standards.
for temperature derations.
C/F = Consult Factory / Detroit Diesel MTU Peru
N/A = Not Available
Consult Detroit Diesel MTU Peru for additional configurations.